Table of Contents
- Notices
- Chapter 1: Product Introduction
- Chapter 2: Hardware Information
- Chapter 3: Installation Options
- Chapter 4: Motherboard Information
- Chapter 5: BIOS Setup
- 5.1 Managing and updating your BIOS
- 5.2 BIOS setup program
- 5.3 Main menu
- 5.4 Advanced menu
- 5.4.1 ACPI Settings
- 5.4.2 Smart Settings
- 5.4.3 NCT6779D Super IO Configuration
- 5.4.4 Intel LAN I210 IO Configuration
- 5.4.5 Serial Port Console Redirection
- 5.4.6 APM
- 5.4.7 PCI Subsystem Settings
- 5.4.8 Network Stack Configuration
- 5.4.9 CSM Configuration
- 5.4.10 Trusted Computing
- 5.4.11 USB Configuration
- 5.4.12 iSCSI Configuration
- 5.5 IntelRCSetup menu
- 5.5.1 Processor Configuration
- 5.5.2 Advanced Power Management Configuration
- 5.5.3 Common RefCode Configuration
- 5.5.4 QPI Configuration
- 5.5.5 Memory Configuration
- 5.5.6 IIO Configuration
- 5.5.7 PCH Configuration
- 5.5.8 Miscellaneous Configuration
- 5.5.9 Server ME Configuration
- 5.5.10 Runtime Error Logging Support
- 5.6 Server Mgmt menu
- 5.7 Event Logs menu
- 5.8 Monitor menu
- 5.9 Security menu
- 5.10 Boot menu
- 5.11 Tool menu
- 5.12 Exit menu
- Chapter 6: RAID Configuration
- Chapter 7: Driver Installation
- 7.1 RAID driver installation
- 7.2 Management applications and utilities installation
- 7.3 Running the Support DVD
- 7.4 Intel® chipset device software installation
- 7.5 Installing the Intel® I210 Gigabit Adapters driver
- 7.6 VGA driver installation
- 7.7 Intel® Rapid Storage Technology enterprise 4.0 installation
- Appendix
ASUS TS500-E8-PS4 V2 User Manual
Displayed below is the user manual for TS500-E8-PS4 V2 by ASUS which is a product in the Server Barebones category. This manual has pages.
Related Manuals
Pedestal/5U Rackmount
Server
User Guide
TS500-E8-PS4 V2
ii
Copyright © 2015 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language in any form or by any means,
except documentation kept by the purchaser for backup purposes, without the express written permission
of ASUSTeK COMPUTER INC. (“ASUS”).
ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not
limited to the implied warranties or conditions of merchantability or tness for a particular purpose. In no
event shall ASUS, its directors, ofcers, employees, or agents be liable for any indirect, special, incidental,
or consequential damages (including damages for loss of prots, loss of business, loss of use or data,
interruption of business and the like), even if ASUS has been advised of the possibility of such damages
arising from any defect or error in this manual or product.
Specications and information contained in this manual ae furnished for informational use only, and are
subject to change at any time without notice, and should not be construed as a commitment by ASUS.
ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual,
including the products and software described in it.
Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless
such repair, modication of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identication or explanation and to the
owners’ benet, without intent to infringe.
E10677
First Edition
August 2015
iii
Contents
Notices ...................................................................................................................... vii
REACH ......................................................................................................vii
Safety information .................................................................................................... viii
Australia statement notice ...............................................................................ix
About this guide .......................................................................................................... x
Chapter 1: Product Introduction
1.1 System package contents ......................................................................... 1-2
1.2 Serial number label .................................................................................... 1-3
1.3 System specifications ...............................................................................1-4
1.4 Front panel features ...................................................................................1-6
1.5 Rear panel features ....................................................................................1-7
1.6 Internal features .........................................................................................1-8
Chapter 2: Hardware Information
2.1 Chassis cover .............................................................................................2-2
2.1.1 Removing the side cover............................................................. 2-2
2.1.2 Reinstalling the side cover .......................................................... 2-3
2.2 Central Processing Unit (CPU) .................................................................2-4
2.2.1 Installing the CPU ....................................................................... 2-4
2.3 System memory .......................................................................................2-11
2.3.1 Overview ................................................................................... 2-11
2.3.2 Memory Congurations ............................................................. 2-12
2.3.3 Installing a DIMM on a single clip DIMM socket........................ 2-13
2.4 Front panel assembly ..............................................................................2-14
2.4.1 Removing the front panel assembly .......................................... 2-14
2.4.2 Reinstalling the front panel assembly ....................................... 2-14
2.5 5.25-inch drives ........................................................................................ 2-15
2.6 SATA/SAS hard disk drives ....................................................................2-16
2.6.1 Installing the HDD module cage................................................ 2-16
2.6.2 Removing the HDD module cage.............................................. 2-17
2.6.3 Installing a hot-swap SATA/SAS hard disk drive ...................... 2-18
2.6.4 Removing the backplane........................................................... 2-20
2.7 Expansion cards ......................................................................................2-21
2.7.1 Installing an expansion card...................................................... 2-21
2.7.2 Installing an ASUS PIKE II card ................................................ 2-23
2.8 Cable connections ...................................................................................2-26
2.8.1 Motherboard connections.......................................................... 2-26
2.8.2 SATA/SAS backplane cabling ................................................... 2-28
iv
Contents
2.9 Removable components ..........................................................................2-30
2.9.1 System fan ................................................................................ 2-30
2.9.2 Chassis footpads....................................................................... 2-32
Chapter 3: Installation Options
3.1 Preparing the system for rack mounting ................................................. 3-2
3.2 Attaching the inner rail to the server .......................................................3-3
3.3 Attaching the rails to the rack ..................................................................3-3
3.4 Mounting the server to the rack ...............................................................3-4
Chapter 4: Motherboard Information
4.1 Motherboard layout ....................................................................................4-2
4.2 Jumpers ......................................................................................................4-5
4.3 Internal connectors ....................................................................................4-9
4.4 Onboard LEDs .......................................................................................... 4-18
Chapter 5: BIOS Setup
5.1 Managing and updating your BIOS ..........................................................5-2
5.1.1 ASUS CrashFree BIOS 3 utility................................................... 5-2
5.1.2 ASUS EZ Flash Utility ................................................................. 5-3
5.1.3 BUPDATER utility ....................................................................... 5-4
5.2 BIOS setup program ..................................................................................5-6
5.2.1 BIOS menu screen ...................................................................... 5-7
5.2.2 Menu bar ..................................................................................... 5-7
5.2.3 Menu items.................................................................................. 5-8
5.2.4 Submenu items ........................................................................... 5-8
5.2.5 Navigation keys ........................................................................... 5-8
5.2.6 General help................................................................................ 5-8
5.2.7 Conguration elds ..................................................................... 5-8
5.2.8 Pop-up window............................................................................ 5-8
5.2.9 Scroll bar ..................................................................................... 5-8
5.3 Main menu ..................................................................................................5-9
5.3.1 System Date [Day xx/xx/xxxx] ..................................................... 5-9
5.3.2 System Time [xx:xx:xx] ............................................................... 5-9
5.4 Advanced menu .......................................................................................5-10
5.4.1 ACPI Settings ............................................................................ 5-11
5.4.2 Smart Settings........................................................................... 5-11
5.4.3 NCT6779D Super IO Conguration .......................................... 5-12
v
Contents
5.4.4 Intel LAN I210 IO Conguration ............................................... 5-13
5.4.5 Serial Port Console Redirection ................................................ 5-14
5.4.6 APM .......................................................................................... 5-17
5.4.7 PCI Subsystem Settings ........................................................... 5-18
5.4.8 Network Stack Conguration..................................................... 5-19
5.4.9 CSM Conguration .................................................................... 5-20
5.4.10 Trusted Computing.................................................................... 5-21
5.4.11 USB Conguration .................................................................... 5-22
5.4.12 iSCSI Conguration................................................................... 5-23
5.5 IntelRCSetup menu .................................................................................. 5-24
5.5.1 Processor Conguration............................................................ 5-25
5.5.2 Advanced Power Management Conguration........................... 5-27
5.5.3 Common RefCode Conguration .............................................. 5-28
5.5.4 QPI Conguration...................................................................... 5-29
5.5.5 Memory Conguration ............................................................... 5-30
5.5.6 IIO Conguration ....................................................................... 5-33
5.5.7 PCH Conguration .................................................................... 5-34
5.5.8 Miscellaneous Conguration ..................................................... 5-38
5.5.9 Server ME Conguration ........................................................... 5-38
5.5.10 Runtime Error Logging Support ................................................ 5-39
5.6 Server Mgmt menu ...................................................................................5-39
5.7 Event Logs menu .....................................................................................5-44
5.7.1 Change Smbios Event Log Settings ......................................... 5-44
5.7.2 View Smbios Event Log ............................................................ 5-45
5.8 Monitor menu ...........................................................................................5-46
5.9 Security menu ..........................................................................................5-47
5.10 Boot menu ................................................................................................5-50
5.11 Tool menu ................................................................................................. 5-51
5.12 Exit menu .................................................................................................. 5-52
Chapter 6: RAID Configuration
6.1 Setting up RAID ..........................................................................................6-2
6.1.1 RAID denitions .......................................................................... 6-2
6.1.2 Installing hard disk drives ............................................................ 6-3
6.1.3 Setting the RAID item in BIOS .................................................... 6-3
6.1.4 RAID conguration utilities .......................................................... 6-3
vi
Contents
6.2 LSI Software RAID Configuration Utility (Z10PA-D8 only) .....................6-4
6.2.1 Creating a RAID set .................................................................... 6-5
6.2.2 Adding or viewing a RAID conguration.................................... 6-11
6.2.3 Initializing the virtual drives ....................................................... 6-12
6.2.4 Rebuilding failed drives ............................................................. 6-16
6.2.5 Checking the drives for data consistency.................................. 6-18
6.2.6 Deleting a RAID conguration ................................................... 6-21
6.2.7 Selecting the boot drive from a RAID set .................................. 6-22
6.2.8 Enabling WriteCache ................................................................ 6-23
6.3 Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM Utility ...........................................................6-24
6.3.1 Creating a RAID set .................................................................. 6-25
6.3.2 Deleting a RAID set................................................................... 6-27
6.3.3 Resetting disks to Non-RAID .................................................... 6-28
6.3.4 Exiting the Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM utility .............................................. 6-29
6.3.5 Rebuilding the RAID.................................................................. 6-29
6.3.6 Setting the Boot array in the BIOS Setup Utility ........................ 6-31
6.4 Intel® Rapid Storage Technology enterprise (Windows) ......................6-32
6.4.1 Creating a RAID set .................................................................. 6-33
6.4.2 Changing a Volume Type.......................................................... 6-35
6.4.3 Deleting a volume ..................................................................... 6-36
6.4.4 Preferences ............................................................................... 6-37
Chapter 7: Driver Installation
7.1 RAID driver installation .............................................................................7-2
7.1.1 Creating a RAID driver disk......................................................... 7-2
7.1.2 Installing the RAID controller driver............................................. 7-3
7.2 Management applications and utilities installation ..............................7-13
7.3 Running the Support DVD ......................................................................7-13
7.4 Intel® chipset device software installation ............................................7-17
7.5 Installing the Intel® I210 Gigabit Adapters driver ..................................7-19
7.6 VGA driver installation ............................................................................7-22
7.7 Intel® Rapid Storage Technology enterprise 4.0 installation ............... 7-24
Appendix
ASUS contact information ...................................................................................... A-2
vii
Notices
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with manufacturer’s instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Canadian Department of Communications Statement
This digital apparatus does not exceed the Class A limits for radio noise emissions from
digital apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
This Class A digital apparatus complies with Canadian ICES-003.
WARNING! The use of shielded cables for connection of the monitor to the graphics card
is required to assure compliance with FCC regulations. Changes or modications to this
unit not expressly approved by the party responsible for compliance could void the user’s
authority to operate this equipment.
REACH
Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of
Chemicals) regulatory framework, we publish the chemical substances in our products at
ASUS REACH website at http://csr.asus.com/english/REACH.htm.
viii
Safety information
Electrical Safety
• Before installing or removing signal cables, ensure that the power cables for the system
unit and all attached devices are unplugged.
• To prevent electrical shock hazard, disconnect the power cable from the electrical outlet
before relocating the system.
• When adding or removing any additional devices to or from the system, ensure that the
power cables for the devices are unplugged before the signal cables are connected. If
possible, disconnect all power cables from the existing system before you add a device.
• If the power supply is broken, do not try to x it by yourself. Contact a qualied service
technician or your dealer.
Operation Safety
• Any mechanical operation on this server must be conducted by certied or experienced
engineers.
• Before operating the server, carefully read all the manuals included with the server
package.
• Before using the server, ensure all cables are correctly connected and the power cables
are not damaged. If any damage is detected, contact your dealer as soon as possible.
• To avoid short circuits, keep paper clips, screws, and staples away from connectors,
slots, sockets and circuitry.
• Avoid dust, humidity, and temperature extremes. Place the server on a stable surface.
Lithium-Ion Battery Warning
CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with
the same or equivalent type recommended by the manufacturer. Dispose of used
batteries according to the manufacturer’s instructions.
CD-ROM Drive Safety Warning
CLASS 1 LASER PRODUCT
Heavy System
CAUTION! This server system is heavy. Ask for assistance when moving or carrying
the system.
This product is equipped with a three-wire power cable and plug for the user’s safety. Use
the power cable with a properly grounded electrical outlet to avoid electrical shock.
ix
DO NOT throw the motherboard in municipal waste. This product has been designed to
enable proper reuse of parts and recycling. This symbol of the crossed out wheeled bin
indicates that the product (electrical and electronic equipment) should not be placed in
municipal waste. Check local regulations for disposal of electronic products.
DO NOT throw the mercury-containing button cell battery in municipal waste. This symbol
of the crossed out wheeled bin indicates that the battery should not be placed in municipal
waste.
Australia statement notice
From 1 January 2012 updated warranties apply to all ASUS products, consistent with the
Australian Consumer Law. For the latest product warranty details please visit
http://support.asus.com. Our goods come with guarantees that cannot be excluded under the
Australian Consumer Law. You are entitled to a replacement or refund for a major failure and
compensation for any other reasonably foreseeable loss or damage. You are also entitled
to have the goods repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
If you require assistance please call ASUS Customer Service 1300 2787 88 or visit us at
http://support.asus.com
x
About this guide
Audience
This user guide is intended for system integrators, and experienced users with at least basic
knowledge of conguring a server.
Contents
This guide contains the following parts:
1. Chapter 1: Product Introduction
This chapter describes the general features of the server, including sections on front
panel and rear panel specications.
2. Chapter 2: Hardware Information
This chapter lists the hardware setup procedures that you have to perform when
installing or removing system components.
3. Chapter 3: Installation Options
This chapter describes how to install optional components into the barebone server.
4. Chapter 4: Motherboard Information
This chapter includes the motherboard layout and brief descriptions of the jumpers and
internal connectors.
5. Chapter 5: BIOS Setup
This chapter tells how to change system settings through the BIOS Setup menus and
describes the BIOS parameters.
6. Chapter 6: RAID Configuration
This chapter provides instructions for setting up, creating and conguring RAID sets
using the available utilities.
7. Chapter 7: Driver Installation
This chapter provides instructions for installing the necessary drivers for different
system components.
xi
References
Refer to the following sources for additional information, and for product and software
updates.
1. ASUS Server Web-based Management (ASWM) user guide
This manual tells how to set up and use the proprietary ASUS server management
utility.
2. ASUS websites
The ASUS websites worldwide provide updated information for all ASUS hardware and
software products. Refer to the ASUS contact information.
Conventions
To ensure that you perform certain tasks properly, take note of the following symbols used
throughout this manual.
Typography
Bold text Indicates a menu or an item to select.
Italics
Used to emphasize a word or a phrase.
<Key> Keys enclosed in the less-than and greater-than
sign means that you must press the enclosed key.
Example: <Enter> means that you must press
the Enter or Return key.
<Key1>+<Key2+<Key3> If you must press two or more keys simultaneously,
the key names are linked with a plus sign (+).
Example: <Ctrl>+<Alt>+<Del>
Command Means that you must type the command
exactly as shown, then supply the required
item or value enclosed in brackets.
Example: At the DOS prompt, type the
command line: format A:/S
DANGER/WARNING: Information to prevent injury to yourself when
trying to complete a task.
CAUTION: Information to prevent damage to the components when
trying to complete a task.
NOTE: Tips and additional information to help you complete a task.
IMPORTANT: Instructions that you MUST follow to complete a task.
xii
1
Product Introduction
This chapter describes the motherboard features and the new
technologies it supports.
Chapter 1: Product Introduction
Chapter 1: Product Introduction
1-2
*ASUS System Web-based Management
If any of the above items is damaged or missing, contact your retailer.
1.1 System package contents
Check your system package for the following items.
Model Name TS500-E8-PS4 V2
Chassis ASUS T50A Pedestal 5U Rackmount Chassis
Motherboard ASUS Z10PA-D8 Server Board
Component
1 x 500W 80PLUS Bronze Single Power Supply
4 x hot-swap HDD trays
1 x SAS/SATA2 Backplane
1 x Front I/O Board
• 1 x Front (80mm x 38mm) system fans
• 1 x Rear (120mm x 38mm) system fan
Accessories
1 x TS500-E8-PS4 Support CD (including ASWM*)
1 x Bag of screws
1 x ASMB8 Series DVD
1 x AC Power Cable
Optional
Items
2 x CPU Heatsinks
DVD-ROM / DVD-RW
ASUS TS500-E8-PS4 V2 1-3
1.2 Serial number label
Before requesting support from the ASUS Technical Support team, you must take note of the
product’s serial number containing 12 characters such as xxS0xxxxxxxx shown as the gure
below. With the correct serial number of the product, ASUS Technical Support team members
can then offer a quicker and satisfying solution to your problems.
xxS0xxxxxxxx
TS500-E8-PS4 V2
Chapter 1: Product Introduction
1-4
1.3 System specifications
The ASUS TS500-E8-PS4 V2 is a 5U barebone server system featuring the
ASUS Z10PA-D8 Server Board. The server supports Intel® LGA2011-3 Intel®
Xeon® E5-2600 Processor v3 plus other latest technologies through the chipsets
onboard.
(continued on the next page)
Model Name TS500-E8-PS4 V2
Processor Support / System
Bus
2 x Socket R3 LGA 2011-3
Intel® Xeon® Processor E5-2600 v3 product Family
QPI 6.4 / 8.0 / 9.6 GT/s
Core Logic Intel® C612 PCH Chipset
Memory
Total Slots 8 (4 Channels per CPU, 4 DIMM per CPU)
Capacity Maximum up to 256 GB
Memory Type
DDR4 2133 / 1866 / 1600 / 1333* RDIMM / LR-DIMM/ NVDIMM
* Refer to www.asus.com for the latest memory AVL update.
Memory Size 32 GB, 16 GB, 8 GB, 4 GB, 2 GB (RDIMM)
64 GB, 32 GB, 8 GB (LRDIMM)
Expansion
Slots
Total PCI/
PCI-X/ PCI-E/
PIKE Slots
6
Slot Type
1 x PCI-E x8 (Gen2 x4 link) +
3 x PCI-E x8 (Gen3 x8 link) +
2 x PCI-E x16 (Gen3 x8 link)
or
1 x PCI-E x8 (Gen2 x4 link) +
1 x PCI-E x8 (Gen3 x8 link) +
2 x PCI-E x16 (Gen3 x16 link)
Storage
SATA Controller
Intel® C612
10 x SATA 6 6Gb/s ports (1 for SATA 6Gb/s ports or M.2
connector)
1 x M.2 connector
Intel® RSTe
(for Windows only; supports software RAID 0, 1, 10, and 5)
SAS Controller
Optional kits:
ASUS PIKE 3008 8-port SAS RAID card
ASUS PIKE 3108 8-port SAS HW RAID card
HDD Bays
I = internal
A or S = hot-
swappable
4 x Hot-swap 3.5-inch HDD Bays
Networking LAN 2 x Intel® I210AT
1 x Management port
Graphic VGA Aspeed AST2400 32MB
ASUS TS500-E8-PS4 V2 1-5
*Specifications are subject to change without notice.
Model Name TS500-E8-PS4 V2
Auxiliary Storage Device Bay
(Floppy / Optical Drive)
3 x 5.25" media bays
(Options: No Device / DVD-RW)
Rear I/O Connectors
2 x USB 2.0 ports
2 x USB 3.0 ports
1 x VGA port
2 x RJ-45 GbE LAN
1 x RJ-45 Mgmt LAN
1 x PS/2 keyboard/mouse port
OS Support
Windows® Server 2012 R2
Windows® Server 2012
Windows® Server 2008 R2
RedHat® Enterprise Linux
SuSE® Linux Enterprise Server
CentOS
Ubuntu
VMware
Citrix XenServer
Please nd the latest OS support from http://www.asus.com/
(Subject to change without any notice)
Management
Solution
Software ASWM Enterprise
Out of Band
Remote
Management
ASMB8-iKVM for KVM-over-Internet
Regulatory Compliance BSMI, CE, C-TICK, FCC(Class B)
Dimension 455 mm x 217.5 mm x 545 mm
Net Weight Kg
(CPU, DRAM & HDD not
included)
17 Kg
Power Supply (following
different configuration by
region)
500W 80PLUS Bronze Single Power Supply
Rating: 100-240V, 7-3.5A, 50 / 60Hz, Class I
Environment
Operating temperature: 10°C – 35°C
Non operation temperature: -40°C – 70°C
Non operation humidity: 20% – 90% (Non condensing)
Chapter 1: Product Introduction
1-6
1.4 Front panel features
Optical drive
(optional)
Empty 5.25-inch bays
Power button
Reset button
Message LED
HDD access LED
Power LED
USB 2.0 ports
Security lock
4-bay HDD cage
LAN1 LED
LAN2 LED
USB 3.0 ports
4-bay HDD cage (Optional Set)
Locate LED
(Reserved)
Headset port*
Mic In port*
1. Refer to section 1.7.1 Front panel LEDs for the LED descriptions.
2. * The Headset and Mic In ports are only available when an audio card is installed.
ASUS TS500-E8-PS4 V2 1-7
1.5 Rear panel features
Expansion slots
USB 2.0 ports
USB 3.0 ports
VGA port
Chassis intrusion switch
Gigabit LAN ports
Chassis lock
120mm x 38mm system fan
PS/2 mouse/keyboard port
Power connector
LAN port*
*This port is for the ASUS ASMB8-iKVM controller only.
Chapter 1: Product Introduction
1-8
1.6 Internal features
The barebone server includes the basic components as shown.
1. 500W Power Supply
2. 120mm x 38mm system fan
3. ASUS Z10PA-D8 Server Board
4. Chassis intrusion switch
5. Expansion card locks
6. Optical drive (optional)
7. 2 x 5.25-inch drive bays
8. 4-bay HDD module (rst set)
9. SATA/SAS backplane board (rst set, hidden)
10. 80mm x 38mm system fans
Turn off the system power and detach the power supply before removing or
replacing any system component.
The barebone server does not include a oppy disk drive and an optical disc
drive. Connect a USB oppy disk drive or a USB ODD to any of the USB ports
on the front or rear panel if you need to use a oppy disk or an optical disc.
ASUS TS500-E8-PS4 V2 1-9
1.7 LED information
1.7.1 Front panel LEDs
Message LED
Drive Status LED
Power LED
LAN1 LED
LAN2 LED
HDD Access LED
LED Icon Display status Description
Power LED ON System power ON
HDD Access LED OFF No activity
Blinking Read/write data into the HDD.
Message LED OFF System is normal; no incoming event
Lighting up
A hardware temperature overheat is
detected. Use ASWM to check the
abnormal status.
Drive status LED Green Bridge board connected to backplane
Installed HDD is in good condition
Red HDD failure
Green/Red Blinking HDD rebuilding using the RAID card
LAN LEDs
OFF
Blinking LAN accessing
ON
Locate LED ON Locates a specic server
The Power, HDD Access, LAN and Message LEDs are visible even if the
system front bezel is closed.
Locate LED (Reserved)
Chapter 1: Product Introduction
1-10
1.7.2 Rear panel LEDs
ACT/LINK LED SPEED LED
Status Description Status Description
OFF No link OFF 10 Mbps connection
GREEN Linked ORANGE 100 Mbps connection
BLINKING Data activity GREEN 1 Gbps connection
SPEED LED
ACT/LINK LED
SPEED LED
ACT/LINK LED
SPEED LED
ACT/LINK LED
This chapter lists the hardware setup procedures that you have
to perform when installing or removing system components.
2
Hardware Information
Chapter 2: Hardware Information
Chapter 2: Hardware Setup
2-2
2.1 Chassis cover
2.1.1 Removing the side cover
• Ensurethatyouunplugthepowercordbeforeremovingthesidecover.
• Takeextracarewhenremovingthesidecover.Keepyourngersfromcomponents
inside the chassis that can cause injury, such as the CPU fan, rear fan, and other
sharp-edged parts.
2. Slidethesidecoverforabouthalf
an inch toward the rear until it is
disengaged from the chassis.
3. Carefully lift the side cover and set it
aside.
1. Remove the two screws that secure
the side cover.
2-3
ASUS TS500-E8-PS4 V2
To reinstall the side cover:
1. Match and insert the lower sliding edge
of the side cover to the corresponding
chassis edge.
2. Slide the side cover toward the front
panel until it snaps in place.
3. Drive in the two screws you removed
earlier to secure the side cover.
2.1.2 Reinstalling the side cover
Chapter 2: Hardware Setup
2-4
2.2.1 Installing the CPU
To install a CPU:
1. LocatetheCPUsocketonthemotherboard.
2.2 Central Processing Unit (CPU)
ThemotherboardcomeswithasurfacemountLGA2011-3SocketdesignedfortheIntel®
XeonE5-2600v3processorfamily.
• Uponpurchaseofthemotherboard,ensurethatthePnPcapisonthesocketand
thesocketcontactsarenotbent.ContactyourretailerimmediatelyifthePnPcap
ismissing,orifyouseeanydamagetothePnPcap/socketcontacts/motherboard
components.ASUSwillshoulderthecostofrepaironlyifthedamageisshipment/
transit-related.
• Keepthecapafterinstallingthemotherboard.ASUSwillprocessReturnMerchandise
Authorization(RMA)requestsonlyifthemotherboardcomeswiththecapontheLGA
2011-3socket.
• Theproductwarrantydoesnotcoverdamagetothesocketcontactsresultingfrom
incorrect CPU installation/removal, or misplacement/loss/incorrect removal of the PnP
cap.
BeforeinstallingtheCPU,ensurethatthesocketboxisfacingtowardyouandthetriangle
markisonthetop-rightposition.
Triangle mark
2-5
ASUS TS500-E8-PS4 V2
2. Presstheleftloadleverdownwithyourthumb(A),moveittotherightuntilitis
releasedfromtheretentiontab(B)thengentlylifttheloadlever(C).
Topreventdamagetothesocketpins,donotremovethePnPcapunlessyouareinstalling
a CPU.
3. Presstherightloadleverwithyourthumb(D),move it to the left until it is released from
thengentlylifttheloadlever(F).
Load lever
Chapter 2: Hardware Setup
2-6
9. Gentlypushtheloadplatejustenough
to let it sit on top of the CPU.
Do not force to close the load plate
as it may damage the CPU.
4. Push the left load lever to slightly lift the
loadplate(G).
Do not insert the load lever into the
retentiontab.
TheCPUtsinonlyonecorrect
orientation. DO NOT force the CPU
intothesockettopreventbendingthe
CPUpinsonthesocket.
6. GettheCPU.
7. AlignandpositiontheCPUoverthe
socketensuringthatthetrianglemarkon
theCPUmatchesthetrianglemarkon
thesocketbox.
Triangle mark
5. Holdtheedgethengentlylifttheload
plate(H).
8. InstalltheCPUintotheslot.
Load plate
edge of the Load plate
2-7
ASUS TS500-E8-PS4 V2
10. Pushdowntherightloadlever(I)ensuringthattheedgeoftheloadplateisxedand
tuckedsecurelyunderthelever(J)theninsert the right load lever under the retention
tab(K).
The PnP cap pops out of the load plate when the right load lever is inserted into the
retentiontab.
KeepthePnPcap.ASUSwillprocessReturnMerchandiseAuthorization(RMA)requests
onlyifthemotherboardcomeswiththePnPcapontheLGA2011-3socket.
11. Pushdowntheleftloadlever(L)then
insertitundertheretentiontab(M). Retention tab
PnP cap
Chapter 2: Hardware Setup
2-8
13. ConnecttheCPUfancabletotheconnectoronthemotherboardlabeledCPU_FAN1/
CPU_FAN2.
DONOTforgettoconnecttheCPUfanconnector!Hardwaremonitoringerrorscanoccurif
you fail to plug this connector.
TheThermalInterfaceMaterialistoxicandinedible.DONOTeatit.Ifitgetsintoyoureyes
ortouchesyourskin,washitoffimmediately,andseekprofessionalmedicalhelp.
• EnsurethattheThermalInterface
Material is spread in an even thin
layer.
• Someheatsinkscomewith
pre-appliedThermalInterface
Material.Ifso,skipthisstep.
12. ApplysomeThermalInterfaceMaterial
totheexposedareaoftheCPUthatthe
heatsinkwillbeincontactwith.
2-9
ASUS TS500-E8-PS4 V2
2.2.2 Installing the CPU heatsink
To install the CPU heatsink:
3. Connect the rear fan connector to
REAR_FAN1connector.Alignand
clicktherearfanintoplace.
1. Loose the rear fan retainers with
bothhandstoremovethefanand
unplug the rear fan connector.
2. ConnecttheCPUheatsinkfan
connectortoCPU_FAN2connector.
Chapter 2: Hardware Setup
2-10
DonotforgettoconnecttheCPUheatsinkandfanconnector.Hardware
monitoring errors can occur if you fail to plug this connector.
Tightenthefourheatsinkscrewsinadiagonal
sequence.
4. PlacetheCPUheatsinkandfanontopoftheinstalledCPU,ensuringthat
the four screws match the holes on the support plate, and the arrow on the
fan faces the rear panel of the server chassis.
TwisteachofthefourscrewswithaPhilips(cross)screwdriverjustenough
toattachtheCPUheatsinkandfantothemotherboard.Whenthefour
screwsareattached,tightenthemonebyonetocompletelysecuretheCPU
heatsinkandfan.
2-11
ASUS TS500-E8-PS4 V2
2.3 System memory
2.3.1 Overview
Themotherboardcomeswitheight(8)DoubleDataRate4(DDR4)DualInlineMemory
Modules(DIMM)sockets.
ThegureillustratesthelocationoftheDDR4DIMMsockets:
Chapter 2: Hardware Setup
2-12
Single CPU configuration (must be installed on
CPU1)
DIMM
A1 B1 C1 D1
1 DIMM P
2 DIMMs P P
4 DIMMs P P P P
Dual CPU configuration
YoucanrefertothefollowingrecommendedmemorypopulationforadualCPUconguration.
Single CPU configuration
You can refer to the following recommended memory population for a single CPU
conguration.
Dual CPU configuration
DIMM
A1 B1 C1 D1 E1 F1 G1 H1
2 DIMMs P P
4 DIMMs P P P P
8 DIMMs PPPPPPP P
2.3.2 Memory Configurations
Youmayinstall4GB,8GB,16GB,and32GBRDIMMsor32GBand64GBLR-DIMMsinto
theDIMMsocketsusingthememorycongurationsinthissection.
• RefertoASUSServerAVLfortheupdatedlistofcompatibleDIMMs.
• WheninstallingDIMMs,alwaysstartfromslotA1(CPU1)andE1(CPU2).
• AlwaysinstallDIMMswiththesameCASlatency.Foroptimumcompatibility,itis
recommendedthatyouobtainmemorymodulesfromthesamevendor.
2-13
ASUS TS500-E8-PS4 V2
2.3.3 Installing a DIMM on a single clip DIMM socket
3. HoldtheDIMMatbothendstheninsert
theDIMMintothesocket.Applyforceto
bothendsoftheDIMMsimultaneously
untiltheretainingclipclicksintoplace
andtheDIMMisseatedsecurelyin
place.
Locked Retaining Clip
1. Press the retaining clip outward to
unlocktheDIMMsocket.
2. AlignaDIMMonthesocketsuchthat
thenotchontheDIMMmatchesthe
DIMMslotkeyonthesocket.
Unlocked retaining clip
DIMM notch
DIMM slot key
1. Press the retaining clip outward to
unlocktheDIMM.
2. RemovetheDIMMfromthesocket.
Removing a DIMM from a single clip DIMM socket
• ToinstalltwoormoreDIMMs,refertotheuserguidebundledwiththemotherboard
package.
• Refertotheuserguideforqualiedvendorlistsofthememorymodules.
SupporttheDIMMlightlywithyourngerswhenpressingtheretainingclips.TheDIMM
mightgetdamagedwhenitipsoutwithextraforce.
AlwaysinserttheDIMMintothesocketVERTICALLYtopreventDIMMnotchdamage.
ADIMMiskeyedwithanotchsothatittsinonlyonedirection.DONOTforceaDIMMinto
asocketinthewrongdirectiontoavoiddamagingtheDIMM.
Chapter 2: Hardware Setup
2-14
2.4 Front panel assembly
Beforeyoucaninstalla5.25-inchdrive,youshouldrstremovethefrontpanelassembly(front
bezelandfrontpanelcover).
2.4.1 Removing the front panel assembly
To remove the front panel assembly
1. Locatethethreehookedtabsonthechassisside
rail.
2. Shiftthehookedtabsandtakeoffthefrontbezel.
2.4.2 Reinstalling the front panel assembly
To reinstall the front panel assembly:
1. Hooktheothersideofthefrontpanel
assemblytothechassis.
2. Swingthefrontpanelassemblyand
snapitbackintoplace.
2-15
ASUS TS500-E8-PS4 V2
2.5 5.25-inch drives
Ensuretounplugthepowercablebeforeinstallingorremovinganysystemcomponents.
Failuretodosomaycausedamagetothemotherboardandothersystemcomponents!
Youmustremovethefrontpanelassemblybeforeinstallinga5.25-inchdrive.
Installing a 5.25-inch drive
1. Unscrew and remove the metal cover
ofthebaywhereyouwanttoinstallthe
5.25-inchdrive,andtakeofftheplastic
coveronthefrontbezelatthesame
position.
2. Insertthedriveintothebayandslide
thebaylocktotherightuntilitclicksin
place.
3. ConnecttheSATAcabletotheSATA
connectoronthebackofthedrive.
4. Connect a power plug from the power
supply to the power connector on the
backofthedrive.
Thesystemcomeswiththree5.25-inch
drivebayslocatedontheupperfrontpart
ofthechassis.Anopticaldrivethatcomes
standard/optionalwiththesystempackage
occupiestheuppermostbay(labeled1).The
lowerbays(labeled2and3)areavailablefor
additional5.25-inchoptical,zip,oroppydisk
drives.
Chapter 2: Hardware Setup
2-16
2.6 SATA/SAS hard disk drives
Theharddiskdrivemodulecageonthefrontpanel,includingexternallyremovabletraysfor
mountingeitherSATAorSASharddiskdrives,allowsyoutoaccessthedrivetraysbysimply
openingthefrontbezel.
AnHDDmodulecagecomeswithaSATAorSASbackplane.TakenoteofthetypeofHDD
modulecageyoupurchasebeforebuyingharddisks.
2.6.1 Installing the HDD module cage
1. Examinethechassisandensurethebayspaceisfreeofwiresandotherobstructions.
2. LeveltheHDDmodulecagelatch
counterclockwise.
3. InserttheHDDmodulecageintothe
bay.
4. WhentheHDDmodulecageis
completely inserted, the cage latch will
bepushedbackclockwise.
5. Lockthecagelatchproperly.
6. Connecttheappropriatecablestothe
SATA/SASbackplaneontheHDD
module cage.
2-17
ASUS TS500-E8-PS4 V2
2.6.2 Removing the HDD module cage
1. Disconnectallthecablesfromthe
SATA/SASbackplaneontheHDD
module cage.
2. LeveltheHDDmodulecagelatch
counterclockwise.TheHDDmodule
cagewillbepushedoutofthechassis.
3. CompletelypullouttheHDDmodule
cage.
Chapter 2: Hardware Setup
2-18
2.6.3 Installing a hot-swap SATA/SAS hard disk drive
1. Releaseadrivetraybypushingthe
springlocktotheright,andthenpulling
the tray lever outward. The drive tray
ejects slightly after you pull out the lever.
2. Firmlyholdthetrayleverandpullthe
drivetrayoutofthebay.
3. Takenoteofthedrivetrayholes.Each
sidehasthreeholestotdifferenttypes
ofharddiskdrives.Usetwoscrewson
eachsidetosecuretheharddiskdrive.
2-19
ASUS TS500-E8-PS4 V2
4. PlaceaSATA/SASharddiskdriveon
the tray, and then secure it with four
screws.
5. Carefullyinsertthedrivetrayandpush
itallthewaytothedepthofthebayuntil
just a small fraction of the tray edge
protrudes.
Wheninstalled,theSATA/SASconnectoronthedriveconnectstotheSATA/SASinterface
onthebackplane.
6. Pushthetrayleveruntilitclicks,and
secures the drive tray in place. The drive
tray is correctly placed when its front
edgealignswiththebayedge.
7. Repeatsteps1to6ifyouwishtoinstall
asecondSATA/SASdrive.
Chapter 2: Hardware Setup
2-20
2.6.4 Removing the backplane
DONOTremovethebackplaneunlessnecessary!
1. Removeallhot-swapHDDtraysfrom
the chassis.
2. DisconnectallcablesfromtheSATA/
SASbackplane.
3. Loosen the four screws on the
backplane.
4. Firmlyholdthebackplane,andturnitin
the direction of the arrow.
5. Removethebackplanefromthemodule.
2-21
ASUS TS500-E8-PS4 V2
2.7 Expansion cards
Thesystemisdesignedwithanexpansioncardlockontherearpanelforyoutoinstallor
removeanexpansioncardinlesssteps.
Ensuretounplugthepowercordbeforeinstallingorremovingexpansioncards.Failureto
dosomaycauseseveredamagetothemotherboardandothersystemcomponents!
2.7.1 Installing an expansion card
1. Beforeinstallingtheexpansioncard,readthedocumentationthatcamewithitand
makethenecessaryhardwaresettingsforthecard.
2. Laythesystemonitssideonaat,stablesurface.
4. Remove the metal slot cover opposite the
slotwhereyouwishtoinstallanexpansion
card.
3. Pushdowntheexpansioncardlock
latch(stepA)andliftuptheexpansion
cardlock(stepB),asshownintheright
gure.
Chapter 2: Hardware Setup
2-22
5. Alignthecard’sgoldenngerswiththe
slot,andthenpressrmlyuntilthecardis
completely seated on the slot.
6. Pushtheexpansioncardlockbacktoits
originalposition.Alightclickindicates
thatthecardislockedinplace.
Wheninstallingagraphicscardona
PCIex16slot,thePCIeslotrightbeside
it does not function.
2-23
ASUS TS500-E8-PS4 V2
2.7.2 Installing an ASUS PIKE II card
YoucaninstallanASUSPIKEIIcardontheprovidedPCI-Eslotonboard.
ToinstallanASUSPIKEIIcard:
1. Removethedefaultcablefromthemotherboardandthebackplane.
2. Remove the screw on the metal cover and then remove the metal cover, put them
aside for future use.
Chapter 2: Hardware Setup
2-24
3. PrepareyourASUSPIKEIIcard.
4. InserttheexpansioncardintothePCI-Eslot.Ensurethatthegoldenngersaretotally
inserted into the slot.
5. Connectthemini-SASHDcabletotheASUSPIKEIIcard.
connect to ASUS PIKE II
connector 1
2-25
ASUS TS500-E8-PS4 V2
connector 1
6. Connectconnector1ontheASUSPIKEIIcardtoconnector1onthebackplaneusing
themini-SASHDcable.
Chapter 2: Hardware Setup
2-26
2.8 Cable connections
• Thebundledsystemcablesarepre-connectedbeforeshipment.Youdonotneedto
disconnectthesecablesunlessyouwillremovepre-installedcomponentstoinstall
additional devices.
• RefertoChapter4fordetailedinformationontheconnectors.
2.8.1 Motherboard connections
2-27
ASUS TS500-E8-PS4 V2
Standard cables connected to the motherboard
1. 24-pinATXpowerconnector(frompowersupplytomotherboard)
2. 8-pin12Vpowerconnector(frompowersupplytomotherboard)
3. Systemfanconnector(fromsystemfantomotherboard)
4. USBconnector(frommotherboardtofrontI/Oboard)
5. SATAports(miniSASconnectorsupport)connectors(systemdefault;from
motherboardtoSATA/SASbackplane)
6. Systemauxiliarypanelconnector(frommotherboardtofrontI/Oboard)
7. Systempanelconnector(frommotherboardtofrontI/Oboard)
Chapter 2: Hardware Setup
2-28
2.8.2 SATA/SAS backplane cabling
Thesystemcomeswithapre-installedSATA/SASbackplane.TheSATA/SASbackplane
hasfour22-pinSATA/SASconnectorstosupportSerialATAharddiskdrivesandSAShard
diskdrives.Thebackplanedesignincorporatesahot-swapfeaturetoalloweasyconnection
orremovalofSATA/SASharddisks.TheLEDsonthebackplaneconnecttothefrontpanel
LEDstoindicateHDDstatus.Seesection1.7 LED information for details.
Front side
ThefrontsideoftheSATA/SASbackplanefacesthefrontpanelwheninstalled.Thisside
includesfourSATA/SASconnectorsforthehot-swapdrivetrays.
EachSATA/SASconnectorislabeled(HDD1,HDD2,
HDD3,HDD4)soyoucaneasilydeterminetheir
counterpartconnectorsatthebacksideofthebackplane.
Refertothetableforreference.
Drive status LEDs
HDD1
HDD2
HDD3
HDD4
HDD1
HDD Device Front side connector Back side connector
HDD1 HDD1 CON1
HDD2 HDD2 CON2
HDD3 HDD3 CON3
HDD4 HDD4 CON4
2-29
ASUS TS500-E8-PS4 V2
Back side
ThebacksideoftheSATA/SASbackplanefacestherearpanelwheninstalled.Thisside
includesthepowerconnectorsandSATA/SASinterfacesforthemotherboardSerialATA
connectorsortheSAScard.
BPSMB1
PWR1
MSAS_HD1
Connectors Description
MSAS_HD1
ConnectstoSATASGPIO1connectoronthemotherboard
orconnectstoSATA/SASconnectorsontheASUSPIKEII
card
BPSMB1 Connects to AUX_PANEL1connectoronthemotherboard
PWR1 Connects to 4-pin plug of the power supply
Chapter 2: Hardware Setup
2-30
2. Locate the front system fan near the
5.25-inchdrivebays.
3. Squeezethefrontsystemfanlatches
(stepA)andpulloutthefrontsystemfan
(stepB),asshownintherightgure.
4. Followthepreviousinstructionsin
reverse to reinstall the front system fan.
Removing the front system fan
To remove the front system fan:
1. Remove the two screws that secure the
right side cover.
2.9.1 System fan
2.9 Removable components
You may need to remove previously installed system components when installing or removing
system devices, or when you need to replace defective components. This section tells how to
remove the following components:
1. Systemfans(frontandrear)
2. Chassis footpads
3. Redundant power supply module
2-31
ASUS TS500-E8-PS4 V2
Removing the rear system fan
To remove the rear system fan:
1. Unplugthesystemfancablefrom
theREAR_FAN1connectoronthe
motherboard.
2. Shiftthetwohookedtabsleftwardand
rightward respectively, then carefully
remove the system fan.
3. Followthepreviousinstructionsin
reverse to reinstall the rear system fan.
Chapter 2: Hardware Setup
2-32
2.9.2 Chassis footpads
Thebareboneserversystemisshippedwithfourfootpadsattachedtothebottomofthe
chassisforstability.Youneedtoremovethesefootpadsifyouwishtoinstallthesystemtoa
rack(RefertoChapter3:InstallationOptionsofthisuserguide,andtothe“RackmountKit”
userguideforinstructions)
To remove the footpads:
1. Lay the system chassis on its side.
2. Removethefootpadbyrotatingit
counterclockwisewithaPhilips(cross)
screwdriver.
3. Repeat step 1 and 2 to remove the other
three footpads.
This chapter describes how to install the optional components
and devices into the barebone server.
3
Installation Options
Chapter 3: Installation Options
Chapter 3: Installation Options
3-2
3.1 Preparing the system for rack mounting
• Theitemsrequiredfortheoptionalcongurationsdescribedinthischapterarenot
includedinthestandardbarebonesystempackage.Theseitemsarepurchased
separately.
• Werecommendthatyouallotatleast1Uspaceabovetheserversystemtoensure
optimalthermalperformance.
Removing the footpads
Refertosection2.9.2Chassisfootpadsforinstructionsonremovingthefootpads.
Removing the top cover
Unscrewandslidethetopcovertoward
therearpanel,andthenliftitupfromthe
chassis.
3-3
ASUS TS500-E8-PS4 V2
3.2 Attaching the inner rail to the server
1. Slideouttheinnerrailfromtherackmountrailkit.
2. Alignthescrewholesontheinnerrail
andthechassistop,andthensecurethe
inner rail to the chassis top with screws.
3. Repeatthepreviousstepstosecure
theotherinnerrailtothebottomofthe
chassis with screws.
3.3 Attaching the rails to the rack
To attach the rails to the rack:
1. Selectoneunitofspace(1U)ontherackwhere
youwishtoinstalltheserver.
1U space
2. Loosenthetwoscrewsontherackrails.
Chapter 3: Installation Options
3-4
3. Alignthefrontendholesofarackrail
pairtothe1Uspace.
4. Driveintwoscrewsontheouterholesto
securethefrontend.
5. Findtherear1Uspacethatcorresponds
tothefront1Uspacewhereyou
attached the rail.
6. Driveintwoscrewsontheouterholesto
securetherearend.
7. Fromtherackfront,ndthe
corresponding1Uspaceforthesecondrailpair.
8. Repeat steps 3–6 to attach the second rail pair.
3.4 Mounting the server to the rack
To mount the server to the rack:
1. Aligntheserverrailswiththerackrails.
2. Pushtheserverallthewayintotherack.
This chapter includes the motherboard layout and brief
descriptions of the jumpers and internal connectors.
4
Motherboard Information
Chapter 4: Motherboard Information
Chapter 4: Motherboard Information
4-2
4.1 Motherboard layout
Z10PA-D8
ASUS TS500-E8-PS4 V2 4-3
Z10PA-D8C
Chapter 4: Motherboard Information
4-4
Layout contents
Jumpers Page
1. Clear RTC RAM (CLRTC1) 4-5
2. VGA controller setting (3-pin VGA_SW1) 4-6
3. LAN controller setting (3-pin LAN_SW1, LAN_SW2) 4-6
4. MErmwareforcerecoverysetting(3-pinME_RCVR1) 4-7
5. DDR4thermaleventsetting(3-pinDIMMTRIP1) 4-7
6. RAIDcongurationutilityselection(3-pinRAID_SEL1) 4-8
7. PMBus1.2PSUselectjumper(3-pinSMART_PSU1) 4-8
Slots/Sockets Page
1. CPUsockets 2-4
2. DDR4sockets 2-9
3. PCIExpressx16/PCIExpressx8 4-17
Internal connectors Page
1. Serial ATA 6.0 Gbps connectors (7-pin SATA1, SATA2, SATA3, SATA4,
SATA5,SATA6[LightBlue]);(7-pinSSATA1,SSATA2,SSATA3[Gray],
SSATA4[LightGray])
4-9
2. M.2 (NGFF) connector (NGFF1) 4-10
3. PowerSupplySMBusconnector(5-pinPSUSMB1) 4-10
4. USB2.0connector(10-1pinUSB34) 4-11
5. USB3.0connector(20-1pinUSB3_34) 4-11
6. CPU, front, and rear fan connectors (4-pin CPU_FAN1, CPU_FAN2,
FRNT_FAN1, FRNT_FAN2, FRNT_FAN3, FRNT_FAN4, FRNT_FAN5,
REAR_FAN1, REAR_FAN2)
4-12
7. Serial port connector (10-1 pin COM1) 4-13
8. TrustedPlatformModuleconnector(20-1pinTPM1) 4-13
9. ATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1, 8-pin
EATX12V2) 4-14
10. Systempanelconnector(20-1pinPANEL1) 4-15
11. Auxiliarypanelconnector(20-2pinAUX_PANEL1) 4-16
12. HarddiskactivityLEDconnector(4-pinHDLED1) 4-17
13. ChassisIntrusionconnector(2-pinINTRUSION1) 4-17
Onboard LEDs Page
1. StandbyPowerLED(SB_PWR1) 4-18
2. BaseboardManagementControllerLED(BMC_LED1) 4-18
3. CPUWarningLED(ERR_CPU1,ERR_CPU2) 4-19
4. CATT LED (CATTERR_LED1) 4-19
5. Q-Code LEDs (LED1) 4-20
ASUS TS500-E8-PS4 V2 4-5
4.2 Jumpers
1. Clear RTC RAM (3-pin CLRTC1)
ThisjumperallowsyoutocleartheRealTimeClock(RTC)RAMinCMOS.Youcan
clear the CMOS memory of date, time, and system setup parameters by erasing the
CMOSRTCRAMdata.TheonboardbuttoncellbatterypowerstheRAMdatainCMOS
whichincludesystemsetupinformationsuchassystempasswords.
To erase the RTC RAM:
1. TurnOFFthecomputerandunplugthepowercord.
2. Movethejumpercapfromthedefaultpins1–2topins2–3.Keepthecaponpins
2–3forabout5to10seconds,thenmovethecapbacktopins1–2.
3. PlugthepowercordandturnONthecomputer.
4. Holddownthe<Del>keyduringthebootprocessandenterBIOSsetuptore-
enter data.
DONOTremovethecaponCLRTCjumperdefaultpositionexceptwhenclearingtheRTC
RAM.Removingthecapwillcausesystembootfailure!
Ifthestepsabovedonothelp,removetheonboardbatteryandmovethejumperagainto
clear the CMOS RTC RAM data. After the CMOS clearance, reinstall the battery.
Chapter 4: Motherboard Information
4-6
2. VGA controller setting (3-pin VGA_SW1)
ThisjumperallowsyoutoenableordisabletheonboardVGAcontroller.Settopins
1–2toactivatetheVGAfeature.
3. LAN controller setting (3-pin LAN_SW1, LAN_SW2)
ThesejumpersallowyoutoenableordisabletheonboardLAN_SW1orLAN_SW2.
Set to pins 1–2toactivatetheGigabitLANfeature.
ASUS TS500-E8-PS4 V2 4-7
4. ME firmware force recovery setting (3-pin ME_RCVR1)
ThisjumperallowsyoutoforceIntel®ManagementEngine(ME)bootfromrecovery
modewhenMEbecomescorrupted.
5. DDR4 thermal event setting (3-pin DIMMTRIP1)
ThisjumperallowsyoutoenableordisableDDR4DIMMthermalsensingeventpin.
Chapter 4: Motherboard Information
4-8
6. RAID configuration utility selection (3-pin RAID_SEL1)
ThisjumperallowsyoutoselecttheRAIDcongurationutilitytousewhenyoucreate
diskarrays.Placethejumpercapsoverpins1–2tousethethirdpartysoftwareLSI
MegaRAIDsoftwareRAIDCongurationUtility;otherwise,placethejumpercapsto
pins2–3tousetheIntel® Rapid Storage Technology enterprise SATA Option ROM
Utility.
7. PMBus 1.2 PSU select jumper (3-pin SMART_PSU1)
ThisjumperallowsyoutoselectPSUPMBusversion.Settopins1–2forPMBus,set
to pins 2–3 for others.
TheRAIDcongurationutilityselectionisavailabletoZ10PA-D8SKUonly.
ASUS TS500-E8-PS4 V2 4-9
• TheactualdatatransferratedependsonthespeedofSerialATAharddisks
installed.
• TheSSATA4[LightGray]willbeautomaticallyturnedoffiftheM.2connector(NGFF)
is occupied.
4.3 Internal connectors
1. Serial ATA 6.0 Gbps connectors (7-pin SATA1, SATA2, SATA3, SATA4, SATA5,
SATA6 [Light Blue]) (7-pin SSATA1, SSATA2, SSATA3 [Gray], SSATA4 [Light
Gray])
SupportedbytheIntel® 612 Series chipset, this connector is for the Serial ATA signal
cablesforSerialATAharddiskdrivesthatallowsupto6Gbpsofdatatransferrate.
IfyouinstalledSerialATAharddiskdrives,youcancreateaRAID0,RAID1,RAID10,
orRAID5conguration.
Chapter 4: Motherboard Information
4-10
2. M.2 (NGFF) connector (NGFF1)
ThisconnectorallowsyoutoinstallanM.2device.
3. Power Supply SMBus connector (5-pin PSUSMB1)
ThisconnectorallowsyoutoconnectSMBus(SystemManagementBus)tothePSU
(powersupplyunit)toreadPSUinformation.DevicescommunicatewithanSMBus
hostand/orotherSMBusdevicesusingtheSMBusinterface.
ThisconnectorfunctionsonlywhenyouinstalltheASUSASMB8.
PowersupplyisrequiredtomeetPMBusspecicationandcustomizedBMCFWmaybe
needed.PleasecontactASUSifyourneedfurthersupport.
Thisconnectorsupportstype2242devicesonbothPCI-EandSATAinterface.
TheM.2(NGFF)deviceispurchasedseparately
ASUS TS500-E8-PS4 V2 4-11
4. USB 2.0 connector (10-1 pin USB34)
TheseconnectorsareforUSB2.0ports.ConnecttheUSBmodulecablesto
connectorsUSB56.TheseUSBconnectorscomplywithUSB2.0specicationthat
supportsupto480Mb/sconnectionspeed.
5. USB 3.0 connector (20-1 pin USB3_34)
ThisconnectorallowsyoutoconnectaUSB3.0moduleforadditionalUSB3.0front
orrearpanelports.WithaninstalledUSB3.0module,youcanenjoyallthebenetsof
USB3.0includingfasterdatatransferspeedsofupto5Gbps,fasterchargingtimefor
USB-chargeabledevices,optimizedpowerefciency,andbackwardcompatibilitywith
USB2.0.
Chapter 4: Motherboard Information
4-12
6. CPU, front, and rear fan connectors (4-pin CPU_FAN1, CPU_FAN2, FRNT_FAN1,
FRNT_FAN2, FRNT_FAN3, FRNT_FAN4, FRNT_FAN5, REAR_FAN1, REAR_FAN2)
The fan connectors support cooling fans. Connect the fan cables to the fan connectors
onthemotherboard,ensuringthattheblackwireofeachcablematchesthegroundpin
of the connector.
• DONOTforgettoconnectthefancablestothefanconnectors.Insufcientairow
inside the system may damage the motherboard components.
• Thesearenotjumpers!DONOTplacejumpercapsonthefanconnectors!
• AllfansfeaturetheASUSSmartFantechnology.
ASUS TS500-E8-PS4 V2 4-13
8. Trusted Platform Module connector (20-1 pin TPM1)
ThisconnectorsupportsaTrustedPlatformModule(TPM)system,whichcansecurely
storekeys,digitalcerticates,passwords,anddata.ATPMsystemalsohelpsenhance
networksecurity,protectsdigitalidentities,andensuresplatformintegrity.
7. Serial port connector (10-1 pin COM1)
This connector is for the serial COM port. Connect the serial port module cable to one
oftheseconnectors,theninstallthemoduletoaslotopeningatthebackofthesystem
chassis.
Chapter 4: Motherboard Information
4-14
9. EATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1, 8-pin EATX12V2)
TheseconnectorsarefortheSSIorATXpowersupplyplugs.Thepowersupplyplugs
aredesignedtottheseconnectorsinonlyoneorientation.Findtheproperorientation
andpushdownrmlyuntiltheconnectorscompletelyt.
• DONOTforgettoconnectthe24+8-pinpowerplugswhenusing85WorbelowCPU;
otherwise,thesystemwillnotbootup.
• DONOTforgettoconnectthe24+8+8-pinpowerplugswhenusing105Worabove
CPU;otherwise,thesystemwillnotbootup.
• UseofaPSUwithahigherpoweroutputisrecommendedwhenconguringasystem
withmorepower-consumingdevices.Thesystemmaybecomeunstableormaynot
bootupifthepowerisinadequate.
• Ensurethatyourpowersupplyunit(PSU)canprovideatleasttheminimumpower
requiredbyyoursystem.MinimumrequirementofATXpowersupply1)500W2)
All+12Voutput>20A.
ASUS TS500-E8-PS4 V2 4-15
10. System panel connector (20-1 pin PANEL1)
Thisconnectorsupportsseveralchassis-mountedfunctions.
1. System power LED (3-pin PLED)
This3-pinconnectorisforthesystempowerLED.Connectthechassispower
LEDcabletothisconnector.ThesystempowerLEDlightsupwhenyouturnon
thesystempower,andblinkswhenthesystemisinsleepmode.
2. Message LED (2-pin MLED)
This 2-pin connector is for the message LED cable that connects to the front
messageLED.ThemessageLEDiscontrolledbyHardwaremonitortoindicate
anabnormaleventoccurance.
3. System warning speaker (4-pin SPEAKER)
This4-pinconnectorisforthechassis-mountedsystemwarningspeaker.The
speakerallowsyoutohearsystembeepsandwarnings.
4. Hard disk drive activity LED (2-pin HDD LED)
This2-pinconnectorisfortheHDDActivityLED.ConnecttheHDDActivityLED
cabletothisconnector.TheHDLEDlightsuporasheswhendataisreadfrom
orwrittentotheHDD.
5. Power button/soft-off button (2-pin PWRSW)
Thisconnectorisforthesystempowerbutton.Pressingthepowerbuttonturns
thesystemonorputsthesysteminsleeporsoft-offmodedependingontheBIOS
settings.Pressingthepowerswitchformorethanfoursecondswhilethesystem
is ON turns the system OFF.
6. Reset button (2-pin RESET)
This 2-pin connector is for the chassis-mounted reset button for system reboot
withoutturningoffthesystempower.
Chapter 4: Motherboard Information
4-16
11. Auxiliary panel connector (20-2 pin AUX_PANEL1)
ThisconnectorisforadditionalfrontpanelfeaturesincludingfrontpanelSMB,locator
LEDandswitch,andLANLEDs.
1. Front panel SMB (10-2 pin FPSMB)
TheseconnectorsareforthefrontpanelSMBuscable.
2. LAN activity LED (2-pin LAN1_LINKACTLED, LAN2_LINKACTLED)
TheseconnectorsareforGigabitLANactivityLEDsonthefrontpanel.
3. Locator LED (2-pin LOCATORLED1, LOCATORLED2)
These connectors are for the locator LED1 and LED2 on the front panel. Connect
theLocatorLEDcablestothese2-pinconnector.TheLEDswilllightupwhenthe
Locator button is pressed.
4. Locator Button/Switch (2-pin LOCATORBTN#)
Theseconnectorsareforthelocatorbuttononthefrontpanel.Thisbuttonqueries
the state of the system locator.
ASUS TS500-E8-PS4 V2 4-17
12. Hard disk activity LED connector (4-pin HDLED1)
This LED connector is for the storage add-on card cable connected to the SATA or
SASadd-oncard.ThereadorwriteactivitiesofanydeviceconnectedtotheSATAor
SAS add-on card causes the front panel LED to light up.
13. Chassis Intrusion (2-pin INTRUSION1)
Theseleadsarefortheintrusiondetectionfeatureforchassiswithintrusionsensoror
microswitch.Whenyouremoveanychassiscomponent,thesensortriggersandsends
ahighlevelsignaltotheseleadstorecordachassisintrusionevent.Thedefaultsetting
isshortCHASSIS#andGNDpinbyjumpercaptodisablethefunction.
Chapter 4: Motherboard Information
4-18
2. Baseboard Management Controller LED (BMC_LED1)
ThegreenheartbeatLEDblinkspersecondtoindicatethattheASMB8isworking
normally.
• TheheartbeatLEDfunctionsonlywhenyouinstalltheASUSASMB8.
• TheBaseboardManagementControllerisavailabletoZ10PA-D8SKUonly.
4.4 Onboard LEDs
1. Standby Power LED (SB_PWR1)
ThemotherboardcomeswithastandbypowerLED.ThegreenLEDlightsupto
indicate that the system is ON, in sleep mode, or in soft-off mode. This is a reminder
thatyoushouldshutdownthesystemandunplugthepowercablebeforeremovingor
plugginginanymotherboardcomponent.Theillustrationbelowshowsthelocationof
the onboard LED.
ASUS TS500-E8-PS4 V2 4-19
3. CPU Warning LED (ERR_CPU1, ERR_CPU2)
TheCPUwarningLEDslightuptoindicatefailureoneitherCPU1,CPU2,orboth.
4. CATT LED (CATTERR_LED1)
TheCATTLEDindicatesthatthesystemhasexperiencedafatalorcatastrophicerror
and cannot continue to operate.
Chapter 4: Motherboard Information
4-20
5. Q-Code LEDs (LED1)
TheQ-CodeLEDprovidesa2-digitdisplaythatshowsthestatusofyoursystem.Refer
to the Q-Code table of this user guide for more information about the 2-digit codes.
ASUS TS500-E8-PS4 V2 4-21
Q-Code table
Action PHASE POST CODE TYPE DESCRIPTION
Normal boot
SecurityPhase
01 Progress Firstpostcode(POWER_ON_POST_CODE)
02 Progress LoadBSPmicrocode(MICROCODE_POST_CODE)
03 Progress SetcacheasramforPEIphase(CACHE_ENABLED_POST_CODE)
06 Progress CPUEarlyinit.(CPU_EARLY_INIT_POST_CODE)
04 Progress initializesSouthbridgeforPEIpreparation
PEI(Pre-EFI
initialization)phase
10 Progress PEICoreEntry
15 Progress NBinitializebeforeinstalledmemory
19 Progress SBinitializebeforeinstalledmemory
78~00 Progress WaitBMCready(duration:120seconds).
A1 MRCProgress QPIinitialization
A3 MRCProgress QPIinitialization
A7 MRCProgress QPIinitialization
A8 MRCProgress QPIinitialization
A9 MRCProgress QPIinitialization
AA MRCProgress QPIinitialization
AB MRCProgress QPIinitialization
AC MRCProgress QPIinitialization
AD MRCProgress QPIinitialization
AE MRCProgress QPIinitialization
AF MRCProgress QPIinitializationComplete
2F Progress MemoryInit.
B0 MRCProgress MemoryInit.
B1 MRCProgress MemoryInit.
AF MRCProgress RCResetifrequire
B4 MRCProgress MemoryInit.
B2 MRCProgress MemoryInit.
B3 MRCProgress MemoryInit.
B5 MRCProgress MemoryInit.
B6 MRCProgress MemoryInit.
B7 MRCProgress MemoryInit.
B8 MRCProgress MemoryInit.
B9 MRCProgress MemoryInit.
BA MRCProgress MemoryInit.
BB MRCProgress MemoryInit.
BC MRCProgress MemoryInit.
BF MRCProgress MemoryInit.Done
5A MRCProgress Othercong.AfterRCend
31 Progress Memory already installed.
32 Progress CPUInit.
34 Progress CPUInit.
36 Progress CPUInit.
4F Progress DXEInitialProgramLoad(IPL)
(continuedonthenextpage)
Chapter 4: Motherboard Information
4-22
Q-Code table
Action PHASE POST CODE TYPE DESCRIPTION
Normal boot
DXE(Driver
Execution
Environment)phase
60 Progress DXE Core Started
61 Progress DXENVRAMInit.
62 Progress SBrun-timeinit.
63 Progress DXECPUInit
68 Progress NBInit.
69 Progress NBInit.
6A Progress NBInit.
70 Progress SBInit.
71 Progress SBInit.
72 Progress SBInit.
78 Progress ACPIInit.
79 Progress CSMInit.
BDS(BootDevice
Selection) phase
90 Progress BDSstarted
91 Progress Connectdeviceevent
92 Progress PCIBusEnumeration.
93 Progress PCIBusEnumeration.
94 Progress PCIBusEnumeration.
95 Progress PCIBusEnumeration.
96 Progress PCIBusEnumeration.
97 Progress Consoleoutoutconnectevent
98 Progress Consoleinputconnectevent
99 Progress AMISuperIOstart
9A Progress AMIUSBDriverInit.
9B Progress AMIUSBDriverInit.
9C Progress AMIUSBDriverInit.
9D Progress AMIUSBDriverInit.
b2 Progress LegacyOptionROMInit.
b3 Progress Reset system
b4 Progress USBhotplug
b6 Progress NVRAM clean up
b7 Progress NVRAMcongurationreset
A0 Progress IDE,AHCIInit.
A1 Progress IDE,AHCIInit.
A2 Progress IDE,AHCIInit.
A3 Progress IDE,AHCIInit.
A8 Progress BIOSSetupUtilitypasswordverify
A9 Progress BIOSSetupUtilitystart
AB Progress BIOSSetupUtilityinputwait
AD Progress Readytobootevent
AE Progress Legacybootevent
Operating system
phase
AA Progress APICmode
AC Progress PICmode
This chapter tells how to change the system settings through
the BIOS Setup menus. Detailed descriptions of the BIOS
parameters are also provided.
5
BIOS Setup
Chapter 5: BIOS Setup
5-2 Chapter 5: BIOS Setup
5.1 Managing and updating your BIOS
The following utilities allow you to manage and update the motherboard Basic Input/Output
System (BIOS) setup:
1. ASUS CrashFree BIOS 3
TorecovertheBIOSusingabootableUSBashdiskdrivewhentheBIOSlefailsor
gets corrupted.
2. ASUS EzFlash
UpdatestheBIOSusingaUSBashdisk.
3. BUPDATER
UpdatestheBIOSinDOSmodeusingabootableUSBashdiskdrive.
Refer to the corresponding sections for details on these utilities.
Recovering the BIOS from a USB flash drive
TorecovertheBIOSfromaUSBashdrive:
1. InserttheUSBashdrivewiththeoriginalorupdatedBIOSletooneUSBportonthe
system.
2. The utility will automatically recover the BIOS. It resets the system when the BIOS
recoverynished.
DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause
system boot failure!
The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the
ASUSwebsiteatwww.asus.comtodownloadthelatestBIOSle.
SaveacopyoftheoriginalmotherboardBIOSletoabootableUSBashdiskdrivein
case you need to restore the BIOS in the future. Copy the original motherboard BIOS using
the BUPDATER utility.
5.1.1 ASUS CrashFree BIOS 3 utility
TheASUSCrashFreeBIOS3isanautorecoverytoolthatallowsyoutorestoretheBIOSle
when it fails or gets corrupted during the updating process. You can update a corrupted BIOS
leusingaUSBashdrivethatcontainstheupdatedBIOSle.
PrepareaUSBashdrivecontainingtheupdatedmotherboardBIOSbeforeusingthis
utility.
ASUS TS500-E8-PS4 V2 5-3
3. Press <Tab> to switch to the Driveeld.
4. PresstheUp/DownarrowkeystondtheUSBashdiskthatcontainsthelatestBIOS,
then press <Enter>.
5. Press <Tab> to switch to the Folder Infoeld.
6. PresstheUp/DownarrowkeystondtheBIOSle,andthenpress<Enter>toperform
the BIOS update process. Reboot the system when the update process is done.
5.1.2 ASUS EZ Flash Utility
The ASUS EZ Flash Utility feature allows you to update the BIOS without having to use a
DOS‑based utility.
Beforeyoustartusingthisutility,downloadthelatestBIOSfromtheASUSwebsiteat
www.asus.com.
To update the BIOS using EZ Flash Utility:
1. InserttheUSBashdiskthatcontainsthelatestBIOSleintotheUSBport.
2. Enter the BIOS setup program. Go to the Tool menu then select ASUS EZ Flash
Utility. Press <Enter>.
ASUS Tek. EzFlash Utility
[Up/Down/Left/Right]:Switch [Enter]:Choose [q]:Exit
FS0 System Volume Information <DIR>
Windows <DIR>
Z10PA-D8 BIOS <DIR>
Current Platform
Platform : Z10PA-D8
Version : 0020
Build Date :04/25/2014
New Platform
Platform : Z10PA-D8
Version : 0022
Build Date :05/05/2014
5-4 Chapter 5: BIOS Setup
5.1.3 BUPDATER utility
The succeeding BIOS screens are for reference only. The actual BIOS screen displays
may not be the same as shown.
TheBUPDATERutilityallowsyoutoupdatetheBIOSleintheDOSenvironmentusinga
bootableUSBashdiskdrivewiththeupdatedBIOSle.
Updating the BIOS file
ToupdatetheBIOSleusingtheBUPDATERutility:
1. VisittheASUSwebsiteatwww.asus.comanddownloadthelatestBIOSleforthe
motherboard.SavetheBIOSletoabootableUSBashdiskdrive.
2. Copy the BUPDATER utility (BUPDATER.exe) from the ASUS support website at
support.asus.comtothebootableUSBashdiskdriveyoucreatedearlier.
3. BootthesysteminDOSmode,thenattheprompt,type:
BUPDATER /i[lename].CAP
where[lename]isthelatestortheoriginalBIOSleonthebootableUSBashdisk
drive,thenpress<Enter>.
A:\>BUPDATER /i[le name].CAP
• ThisfunctioncansupportdevicessuchasaUSBashdiskwithFAT32/16formatand
single partition only.
• DONOTshutdownorresetthesystemwhileupdatingtheBIOStopreventsystem
boot failure!
Ensure to load the BIOS default settings to ensure system compatibility and stability. Press
<F5> and select Yes to load the BIOS default settings.
ASUS TS500-E8-PS4 V2 5-5
4. Theutilityveriesthele,thenstartsupdatingtheBIOSle.
DO NOT shut down or reset the system while updating the BIOS to prevent system boot
failure!
5. The utility returns to the DOS prompt after the BIOS update process is completed.
Rebootthesystemfromtheharddiskdrive.
The BIOS update is nished! Please restart your system.
C:\>
Current Platform
Platform : Z10PA-08
Version : 0301
Build date: 05/13/2014
New Platform
Platform : Z10PA-08
Version : 0301
Build date: 05/13/2014
ASUS Tek. EzFlash Utility
Start Programming Flash. DO NOT SHUTDOWN THE SYSTEM!!!
Write
75%
5-6 Chapter 5: BIOS Setup
5.2 BIOS setup program
Thismotherboardsupportsaprogrammablermwarechipthatyoucanupdateusingthe
provided utility described in section 5.1 Managing and updating your BIOS.
UsetheBIOSSetupprogramwhenyouareinstallingamotherboard,reconguringyour
system,orpromptedto“RunSetup.”Thissectionexplainshowtocongureyoursystem
using this utility.
EvenifyouarenotpromptedtousetheSetupprogram,youcanchangethecongurationof
yourcomputerinthefuture.Forexample,youcanenablethesecuritypasswordfeatureor
changethepowermanagementsettings.Thisrequiresyoutorecongureyoursystemusing
the BIOS Setup program so that the computer can recognize these changes and record them
intheCMOSRAMofthermwarechip.
ThermwarechiponthemotherboardstorestheSetuputility.Whenyoustartupthe
computer,thesystemprovidesyouwiththeopportunitytorunthisprogram.Press<Del>
duringthePower-OnSelf-Test(POST)toentertheSetuputility;otherwise,POSTcontinues
with its test routines.
IfyouwishtoenterSetupafterPOST,restartthesystembypressing<Ctrl+Alt+Delete>,orby
pressing the reset button on the system chassis. You can also restart by turning the system
offandthenbackon.Dothislastoptiononlyifthersttwofailed.
TheSetupprogramisdesignedtomakeitaseasytouseaspossible.Beingamenu-driven
program,itletsyouscrollthroughthevarioussub-menusandmakeyourselectionsfromthe
availableoptionsusingthenavigationkeys.
• ThedefaultBIOSsettingsforthismotherboardapplyformostconditionstoensure
optimum performance. If the system becomes unstable after changing any BIOS
settings,loadthedefaultsettingstoensuresystemcompatibilityandstability.Press
<F5> and select Yes to load the BIOS default settings.
• TheBIOSsetupscreensshowninthissectionareforreferencepurposesonly,and
may not exactly match what you see on your screen.
• VisittheASUSwebsite(www.asus.com)todownloadthelatestBIOSleforthis
motherboard.
ASUS TS500-E8-PS4 V2 5-7
5.2.2 Menu bar
The menu bar on top of the screen has the following main items:
Main Forchangingthebasicsystemconguration
Advanced For changing the advanced system settings
IntelRCSetup For changing the Intel RC settings
Server Mgmt For changing the Server Mgmt settings
Event Logs For changing the event log settings
Monitor Fordisplayingthesystemtemperature,powerstatus,andchanging
the fan settings
Security For changing the security settings
Boot Forchangingthesystembootconguration
Tool Forconguringoptionsforspecialfunctions
Exit For selecting the exit options
Toselectanitemonthemenubar,presstherightorleftarrowkeyonthekeyboarduntilthe
desired item is highlighted.
5.2.1 BIOS menu screen
Navigation keys
General help
Menu bar Configuration fieldsMenu items
5-8 Chapter 5: BIOS Setup
5.2.3 Menu items
Thehighlighteditemonthemenubardisplaysthespecicitemsforthatmenu.Forexample,
selecting Main shows the Main menu items.
Theotheritems(EventLogs,Advanced,Monitor,Boot,Tool,andExit)onthemenubarhave
their respective menu items.
5.2.4 Submenu items
A solid triangle before each item on any menu screen means that the item has a submenu.
Todisplaythesubmenu,selecttheitemthenpress<Enter>.
5.2.5 Navigation keys
AtthebottomrightcornerofamenuscreenarethenavigationkeysfortheBIOSsetup
program.Usethenavigationkeystoselectitemsinthemenuandchangethesettings.
5.2.6 General help
At the top right corner of the menu screen is a brief description of the selected item.
5.2.7 Configuration fields
Theseeldsshowthevaluesforthemenuitems.Ifanitemisuser-congurable,youcan
changethevalueoftheeldoppositetheitem.Youcannotselectanitemthatisnotuser-
congurable.
Acongurableeldisenclosedinbrackets,andishighlightedwhenselected.Tochangethe
valueofaeld,selectitandpress<Enter>todisplayalistofoptions.
5.2.8 Pop-up window
Selectamenuitemandpress<Enter>todisplayapop-upwindowwiththeconguration
options for that item.
5.2.9 Scroll bar
Ascrollbarappearsontherightsideofamenuscreenwhenthereareitemsthatdonott
onthescreen.PresstheUp/Downarrowkeysor<PageUp>/<PageDown>keystodisplay
the other items on the screen.
ASUS TS500-E8-PS4 V2 5-9
5.3 Main menu
WhenyouentertheBIOSSetupprogram,theMainmenuscreenappears.TheMainmenu
providesyouanoverviewofthebasicsysteminformation,andallowsyoutosetthesystem
date,time,language,andsecuritysettings.
5.3.1 System Date [Day xx/xx/xxxx]
Allows you to set the system date.
5.3.2 System Time [xx:xx:xx]
Allows you to set the system time.
5-10 Chapter 5: BIOS Setup
5.4 Advanced menu
The Advanced menu items allow you to change the settings for the CPU and other system
devices.
TakecautionwhenchangingthesettingsoftheAdvancedmenuitems.Incorrecteld
values can cause the system to malfunction.
ASUS TS500-E8-PS4 V2 5-11
5.4.1 ACPI Settings
Enable ACPI Auto Configuration [Disabled]
AllowsyoutoenableordisabletheBIOSACPIAutoConguration.
Congurationoptions:[Disabled][Enabled]
Enable Hibernation [Enabled]
Allows you to enable or disable the ability of the system to hibernate (OS/Sleep State).
Congurationoptions:[Disabled][Enabled]
This option may be not effective with some OS.
5.4.2 Smart Settings
SMART Self Test [Disabled]
Allows you to run SMART Self Test on all HDDs during POST.
Congurationoptions:[Disabled][Enabled]
5-12 Chapter 5: BIOS Setup
5.4.3 NCT6779D Super IO Configuration
Serial Port 1 / Serial Port 2 Configuration
Allows you to set the parameters of Serial Port 1/ Serial Port 2.
Serial Port [Enabled]
Allows you to enable or disable Serial Port.
Congurationoptions:[Disabled][Enabled]
Change Settings [Auto]
Allows you to choose the setting for Super IO device.
Congurationoptions:[Auto][IO=3F8h;IRQ=4;][IO=3F8h;IRQ=3,4,5,6,7,9,10,11,12;]
[IO=2F8h;IRQ=3,4,5,6,7,9,10,11,12;][IO=3E8h;IRQ=3,4,5,6,7,9,10,11,12;]
[IO=2E8h;IRQ=3,4,5,6,7,9,10,11,12;]
ASUS TS500-E8-PS4 V2 5-13
Intel LAN Support [Enabled]
Allows you to enable or disable the Intel LAN.
Congurationoptions:[Disabled][Enabled]
Intel LAN ROM Type [PXE]
Allows you to select the Intel LAN ROM type.
Congurationoptions:[PXE][iSCSI]
Intel LAN I210 LAN1 / LAN2 Enable [Enabled]
Allows you to enable or disable the Intel LAN.
Congurationoptions:[Disabled][Enabled]
ThefollowingitemsappearonlywhenIntelLANI210LAN1/LAN2Enableissetto
[Enabled].
LAN1/ LAN2 Option ROM Support [Enabled]
Allows you to load the Intel LAN ROM.
Congurationoptions:[Disabled][Enabled]
5.4.4 Intel LAN I210 IO Configuration
5-14 Chapter 5: BIOS Setup
5.4.5 Serial Port Console Redirection
Console Redirection Settings
ThisitembecomescongurableonlywhenyouenabletheConsole Redirection item. The
settings specify how the host computer and the remote computer (which the user is using)
will exchange data. Both computers should have the same or compatible settings.
The following item appears only when you set Console Redirection to[Enabled].
COM1/COM2
Console Redirection [Enabled]
Allows you to enable or disable the console redirection feature.
Congurationoptions:[Disabled][Enabled]
ASUS TS500-E8-PS4 V2 5-15
Terminal Type [VT-UTF8]
Allows you to set the terminal type.
[VT100] ASCIIcharset.
[VT100+] ExtendsVT100tosupportcolor,functionkeys,et.
[VT-UTF8] UsesUTF8encodingtomapUnicodecharsonto1ormorebytes
[ANSI] ExtendedASCIIcharset
Bits per second [57600]
Selects serial port transmission speed. The speed must be matched on the other side.
Long or noisy lines may require lower speeds.
Congurationoptions:[9600][19200][38400][57600][115200]
Data Bits [8]
Congurationoptions:[7][8]
Parity [None]
Aparitybitcanbesentwiththedatabitstodetectsometransmissionerrors.[Mark]
and[Space]paritydonotallowforerrordetection.
[None] None
[Even] paritybitis0ifthenumof1’sinthedatabitsiseven
[Odd] paritybitis0ifnumof1’sinthedatabitsisodd
[Mark] paritybitisalways1
[Space] paritybitisalways0
Stop Bits [1]
Stopbitsindicatetheendofaserialdatapacket.(Astartbitindicatesthebeginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than1stopbit.Congurationoptions:[1][2]
Flow Control [Hardware RTS/CTS]
Flowcontrolcanpreventdatalossfrombufferoverow.Whensendingdata,ifthe
receivingbuffersarefull,a“stop”signalcanbesenttostopthedataow.Oncethe
buffersareempty,a“start”signalcanbesenttore-starttheow.Hardwareowcontrol
uses two wires to send start/stop signals.
Congurationoptions:[None][HardwareRTS/CTS]
VT -UTF8 Combo Key Support [Enabled]
ThisallowsyoutoenabletheVT-UTF8CombinationKeySupportforANSI/VT100
terminals.Congurationoptions:[Disabled][Enabled]
Recorder Mode [Disabled]
Withthismodeenabledonlytextwillbesent.ThisistocaptureTerminaldata.
Congurationoptions:[Disabled][Enabled]
Legacy OS Redirection Resolution [80x24]
This allows you to set the number of rows and columns supported on the Legacy OS.
Congurationoptions:[80x24][80x25]
Putty Keypad [VT100]
ThisallowsyoutoselecttheFunctionKeyandKeypadonPutty.Congurationoptions:
[VT100][LINUX][XTERMR6][SCO][ESCN][VT400]
5-16 Chapter 5: BIOS Setup
Serial Port for Out-of-Band Management/
Windows Emergency Management Services (EMS)
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Congurationoptions:[Disabled][Enabled]
Redirection After BIOS POST [Bootloader]
This setting allows you to specify if Bootloader is selected than Legacy console
redirection.Congurationoptions:[AlwaysEnable][Bootloader]
Console Redirection Settings
Out-of-Band Mgmt Port [COM1]
MicrosoftWindowsEmergencyManagementServices(EMS)allowforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[COM1][COM2]
Terminal Type [VT-UTF8]
MicrosoftWindowsEmergencyManagementServices(EMS)allowforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[VT100][VT100+][VT-UTF8][ANSI]
Bits per second [115200]
MicrosoftWindowsEmergencyManagementServices(EMS)allowforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[9600][19200][57600][115200]
Flow Control [None]
MicrosoftWindowsEmergencyManagementServices(EMS)allowforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[None][HardwareRTS/CTS][SoftwareXon/Xoff]
The following item appears only when you set Console Redirection to[Enabled].
ASUS TS500-E8-PS4 V2 5-17
5.4.6 APM
AllowsyoutoconguretheAdvancePowerManagement(APM)settings.
Restore AC Power Loss [Last State]
Whensetto[PowerOff],thesystemgoesintooffstateafteranACpowerloss.Whenset
to[PowerOn],thesystemwillrebootafteranACpowerloss.Whensetto[LastState],the
systemgoesintoeitherofforonstate,whateverthesystemstatewasbeforetheACpower
loss.
Congurationoptions:[PowerOff][PowerOn][LastState]
Power On By PCIE [Disabled]
[Disabled] DisablesthePCIEdevicestogenerateawakeevent.
[Enabled] EnablesthePCIEdevicestogenerateawakeevent.
Power On By Ring [Disabled]
[Disabled] DisablesthePCIEdevicestogenerateawakeevent.
[Enabled] EnablesthePCIEdevicestogenerateawakeevent.
Power On By RTC [Disabled]
[Disabled] DisablesRTCtogenerateawakeevent.
[Enabled] Whensetto[Enabled],theitemsRTC Alarm Date (Days) and Hour/Minute/
Secondwillbecomeuser-congurablewithsetvalues.
5-18 Chapter 5: BIOS Setup
5.4.7 PCI Subsystem Settings
AllowsyoutocongurePCI,PCI-X,andPCIExpressSettings.
Load RT32 Image [Enabled]
Allows you to enable or disable RT32 Image Loading.
Congurationoptions:[Disabled][Enabled]
Above 4G Decoding [Disabled]
Allows you to enable or disable 64‑bit capable devices to be decoded in above 4G address
space.Itonlyworksifthesystemsupports64-bitPCIdecoding.
Congurationoptions:[Disabled][Enabled]
SR-IOV Support [Disabled]
This option enables or disables SIngle Root IO Virtualization Support if the system has SR‑
IOV capable PCIe devices.
Congurationoptions:[Disabled][Enabled]
ASUS TS500-E8-PS4 V2 5-19
Network stack [Disabled]
Enablesordisablesthenetworkstackfeature.Congurationoptions:[Disable][Enable]
5.4.8 Network Stack Configuration
The following item appears only when Network stack is set to[Enabled].
Ipv4 PXE Support [Enabled]
EnablesordisablestheIpv4PXEBootSupport.Ifdisabled,Ipv4PXEbootoptionwill
notbecreated.Congurationoptions:[Disabled][Enabled].
Ipv6 PXE Support [Enabled]
EnablesordisablestheIpv6PXEBootSupport.Ifdisabled,Ipv6PXEbootoptionwill
notbecreated.Congurationoptions:[Disabled][Enabled].
PXE boot wait time [0]
WaittimetopressESCkeytoabortthePXEboot.
Media detect time [0]
Waittime(inseconds)todetectmedia.
5-20 Chapter 5: BIOS Setup
5.4.9 CSM Configuration
CSM Support [Enabled]
This option allows you to enable or disable CSM Support.
Congurationoptions:[Disabled][Enabled]
GateA20 Active [Upon Request]
ThisallowsyoutosettheGA20option.
Congurationoptions:[UponRequest][Always]
Option ROM Messages [Force BIOS]
This allows you to set the display mode for option ROM.
Congurationoptions:[ForceBIOS][KeepCurrent]
Boot Option filter [Legacy only]
This option allows you to control the Legacy/UEFI ROMs priority.
Congurationoptions:[UEFIandLegacy][Legacyonly][UEFIonly]
Network / Storage / Video [Legacy]
ThisoptionallowsyoutocontroltheexecutionofUEFIandLegacyPXE/Storage/Video
OpROM.
Congurationoptions:[UEFI][Legacy]
Other PCI devices [Legacy]
ThisitemdeterminestheOpROMexecutionpolicyfordevicesotherthanNetwork,Storage,
or Video.
Congurationoptions:[UEFI][Legacy]
ASUS TS500-E8-PS4 V2 5-21
5.4.10 Trusted Computing
Configuration
Security Device Support [Disabled]
Allows you to enable or disable the BIOS support for security device.
Congurationoptions:[Disabled][Enabled]
5-22 Chapter 5: BIOS Setup
5.4.11 USB Configuration
Legacy USB Support [Enabled]
Allows you to enable or disable Legacy USB device support.
Congurationoptions:[Enabled][Disabled][Auto]
XHCI Hand-off [Enabled]
Thisisaworkaroundfor0SeswithoutXHCIhand-offsupport.TheXHCIownershipchange
shouldbeclaimedbyXHCIdriver.
Congurationoptions:[Disabled][Enabled]
EHCI Hand-off [Disabled]
Thisisaworkaroundfor0SeswithoutEHCIhand-offsupport.TheEHCIownershipchange
should be claimed by EHCI driver.
Congurationoptions:[Disabled][Enabled]
USB Mass Storage Driver Support [Enabled]
Allows you to enable or disable the USB Mass Storage drvier support.
Congurationoptions:[Disabled][Enabled]
Port 60/64 Emulation [Enabled]
ThisallowsyoutoenabletheI/Oport60h/64hemulationsupport.Thisshouldbeenabledfor
thecompleteUSBkeyboardlegacysupportfornon-USBawareOSes.
Congurationoptions:[Disabled][Enabled]
ASUS TS500-E8-PS4 V2 5-23
USB hardware delays and time-outs
USB transfer time-out [20 sec]
Thetime-outvalueforcontrol,bulk,andinterrupttransfer.
Congurationoptions:[1sec][5sec][10sec][20sec]
Device reset time-out [20 sec]
USB mass storage device start unit command time‑out.
Congurationoptions:[10sec][20sec][30sec][40sec]
Device power-up delay [Auto]
Thisisthemaximumtimethedevicewilltakebeforeitproperlyreportsitselftothehost
controller.
Congurationoptions:[Auto][Manual]
Mass Storage Devices
Generic 8.07 [Auto]
Allows you to select the mass storage device emulation type.
Congurationoptions:[Auto][Floppy][ForcedFDD][HardDisk][CD-ROM]
5.4.12 iSCSI Configuration
AllowsyoutoconguretheiSCSiparameters.
5-24 Chapter 5: BIOS Setup
5.5 IntelRCSetup menu
The IntelRCSetup menu items allow you to change the processor and chipset settings.
ASUS TS500-E8-PS4 V2 5-25
5.5.1 Processor Configuration
Per Socket Configuration
Allowsyoutosetthenumberofcorestoenable.0meansallcores.Totalof14cores
available.
Hyper Threading [Enabled]
Allows you to enable or disable the Intel® Hyper-ThreadingTechnologyfunction.When
disabled,onlyonethreadperactivatedcoreisenabled.
Congurationoptions:[Disabled][Enabled]
Execute Disable Bit [Enabled]
XDcanpreventcertainclassesofmaliciousbufferoverowattackswhencombinedwith
asupportingOS(WindowsServer2003SP1,WindowsXPSP2,SuSELinux9.2,Redhat
Enterprise 3 Update 3).
Congurationoptions:[Disabled][Enabled]
Enable Intel TXT Support [Disabled]
ForcestheXDfeaturelogtoalwaysreturn0whendisabled.
Congurationoptions:[Disabled][Enabled]
VMX [Enabled]
EnablestheVanderpoolTechnology.Takeseffectafterreboot.
Congurationoptions:[Disabled][Enabled]
5-26 Chapter 5: BIOS Setup
Enable SMX [Disabled]
Enables the Safer Mode Extensions
Congurationoptions:[Disabled][Enabled]
Hardware Prefetcher [Enabled]
This Item allows you to turn on/off the mid level cache(L2) streamer prefetcher.
Congurationoptions:[Disabled][Enabled]
Adjacent Cache Prefetch [Enabled]
This Item allows you to turn on/off prefetching of adjacent cache lines.
Congurationoptions:[Disabled][Enabled]
DCU Streamer Prefetcher [Enabled]
This Item allows you to enable or disable prefetcher of next L1 data line.
Congurationoptions:[Disabled][Enabled]
DCU IP Prefetcher [Enabled]
This Item allows you to enable or disable prefetch of next L1 line based upon sequential load
history.
Congurationoptions:[Disabled][Enabled]
DCU Mode [32K 8Way Without ECC]
Congurationoptions:[32K8WayWithoutECC][16K4WayWithECC]
Direct Cache Access (DCA) [Auto]
This Item allows you to enable or disable Direct Cache Access.
Congurationoptions:[Auto][Disabled][Enabled]
DCA Prefetch Delay [32]
This Item allows you to set the time for the DCA Prefetch delay Help.
Congurationoptions:[Disabled][8][16][24][32][40][48][56][64][72][80][88][96][104][112]
X2APIC [Disabled]
This Item allows you to enable or disable the extended APIC support.
Congurationoptions:[Disabled][Enabled]
AES-NI [Enabled]
This Item allows you to enable or disable the AES‑NI support.
Congurationoptions:[Disabled][Enabled]
Down Stream PECI [Disabled]
This Item allows you to enable the PCIe Down Stream PECI writer.
Congurationoptions:[Disabled][Enabled]
ASUS TS500-E8-PS4 V2 5-27
5.5.2 Advanced Power Management Configuration
Power Technology [Energy Efficient]
This item allows you to enable power management features.
Congurationoptions:[Disabled][EnergyEfcient][Custom]
Config TDP [Disabled]
Thisitemallowsyoutoenable/disabletheCongTDP.
Congurationoptions:[Disabled][Enabled]
CPU Advanced PM Turning
This item allows you to set additional CPU Power Management settings.
Energy Perf BIAS
Energy Performance Tuning [Disabled]
Allows your system to select from BIOS or operating system to choose enable energy
performance bias tuning.
Congurationoptions:[Disabled][Enabled]
Energy Performance Bias setting [Balanced Performance]
Allows you to set the Energy Performance Bias which overrides the OS setting.
Congurationoptions:[Performance][BalancedPerformance][BalancedPower]
[Power]
5-28 Chapter 5: BIOS Setup
5.5.3 Common RefCode Configuration
Numa [Enabled]
This item enables or disables the Non uniform Memory Access (NUMA).
Congurationoptions:[Disabled][Enabled]
Power/Performance Switch [Enabled]
Allows you to switch between Power or performance.
Congurationoptions:[Disabled][Enabled]
Workload Configuration [Balanced]
Optimizationfortheworkloadcharacterization.
Congurationoptions:[Balanced][I/Osensitive]
Averaging Time Window [23]
This is used to control the effective window of the average for CO and PO time.
PO TotalTimeThreshold Low [35]
TheHWswitchingmechanismdisablestheperformancesetting(0)whenthetotalPO
time is less than this threshold.
PO TotalTimeThreshold High [58]
TheHWswitchingmechanismenablestheperformancesetting(0)whenthetotalPO
time is greater than this threshold.
ASUS TS500-E8-PS4 V2 5-29
5.5.4 QPI Configuration
QPI Status
QPI General Configuration
QPI Status
ThisitemdisplaysinformationabouttheQPIstatus.
Link Speed Mode [Fast]
ThisitemallowsyoutoselecttheQPIlinkspeedaseitherthefastmodeorslowmode.
Congurationoptions:[Slow][Fast]
Link Frequency Select [Auto]
ThisitemallowsyouforselectingtheQPIlinkfrequency
Congurationoptions:[Auto][6.4GT/s][8.0GT/s][9.6GT/s]
QPI Link0p Enable [Enable]
Congurationoptions:[Disable][Enable]
QPI Link1 Enable [Enable]
Congurationoptions:[Disable][Enable]
5-30 Chapter 5: BIOS Setup
5.5.5 Memory Configuration
Enforce POR [Auto]
Allows you to enforce POR restrictions for DDR4 frequency adn voltage programming.
Congurationoptions:[Auto][EnforcePOR][Disabled][EnforceStretchGoals]
Memory Frequency [Auto]
Allows you to select the memory frequency setting.
Congurationoptions:[Auto][1333][1600][1866][2133]
Halt on mem Training Error [Enabled]
Allows you to enable or disable halt on mem Training Error.
Congurationoptions:[Disabled][Enabled]
ECC Support [Auto]
Allows you to enable or disable the ECC support.
Congurationoptions:[Auto][Disabled][Enabled]
Enhanced Log Parsing [Disabled]
Allows you to enable or disable the Enhanced Log Parsing.
Congurationoptions:[Auto][Disabled][Enabled]
Data Scrambling [Auto]
Allows you to enable/disable data scrambling.
Congurationoptions:[Auto][Disabled][Enabled]
Enable ADR [Disabled]
Allows you to set the detecting and enabling of ADR.
Congurationoptions:[Disabled][Enabled]
ASUS TS500-E8-PS4 V2 5-31
C/A Parity Enable [Auto]
Allows you to enable or disable the DDR4's command address parity.
Congurationoptions:[Auto][Disabled][Enabled]
Memory Topology
Displays memory topology with DIMM population information.
Memory Thermal
Allowsyoutocongurethermalsettings.
Set Throttling Mode [Disabled]
Congurationoptions:[Disabled][OLTT][CLTT]
OLLT Peak BW [xxx]
AllowsyoutosetthepeakallowedbandwidthforOLTT.Thisisinpercentageandvalid
offsetvaluesisfrom25-100.
DIMM Tem Stat [xx]
Allows you to select DIMMTEMPSTAT as temp_mid or tem_hi.
Memory Power Savings Mode [Auto]
AllowsyoutoconguretheCKEandotherrelatedMemoryPowerSavingsfeatures.
Congurationoptions:[Auto][Disabled][APDOn][UserDened][Reserve][Reserved]
Memory Power Savings Advanced Options
CK in SR [Auto]
Congurationoptions:[Auto][Driven][Tri-State][PulledLow]PulledHigh]
MDLL Off [Auto]
Allows you to shutdown MDLL during SR when enabled.
Congurationoptions:[Auto][Disabled][Enabled]
MEMHOT Throttling Mode [Input-only]
Allows you to shutdown MDLL during SR when enabled.
Congurationoptions:[Disabled][Input-only][Output-only]
5-32 Chapter 5: BIOS Setup
Mem Electrical Throttling [Disabled]
AllowsyoutocongureMemoryElecticalthrottling.
Congurationoptions:[Disabled][Enabled][Auto]
Memory Map
Channel Interleaving [Auto]
Select different channel interleaving setting.
Congurationoptions:[Auto][1-wayInterleave][2-wayInterleave][3-wayInterleave]
[4-wayInterleave]
Rank Interleaving [Auto]
Selectdifferentrankinterleavingsetting.
Congurationoptions:[Auto][1-wayInterleave][2-wayInterleave][4-wayInterleave]
[8-wayInterleave]
Memory RAS Configuration
RAS Mode [Disabled]
Allows you to enable or disable RAS Modes. Enabling Sparing and Mirroring is not
supported.Incaseenabled,Sparingwillbeselected.
Congurationoptions:[Disabled][Mirror][LockstepMode]
Memory Rank Sparing [Disabled]
AllowsyoutoenableordisableMemoryRankSparing.
Congurationoptions:[Disabled][Enabled]
Correctable Error Threshold [32767]
AllowsyoutosettheCorrectableErrorThresholdusedforsparing,tagging,andleaky
bucket.Therangeisfrom1to32767.
Patrol Scrub [Enabled]
Allows you to enable or disable Patrol Scrub.
Congurationoptions:[Disabled][Enabled]
Demand Scrub [Enabled]
Allows you to enable or disable Demand Scrub.
Congurationoptions:[Disabled][Enabled]
ASUS TS500-E8-PS4 V2 5-33
EV DFX Features [Disabled]
SetthisoptiontoallowDFXLockBitstoremainclear.
Congurationoptions:[Disabled][Enabled]
PCIE Slot Option ROM Configuration
5.5.6 IIO Configuration
PCIE1/ PCIE2/ PCIE3/ PCIE4/ PCIE6 Option ROM [Disabled]
Allows you to enable or disable the PCIE1/ PCIE2/ PCIE3/ PCIE4/ PCIE6 Option ROM.
Congurationoptions:[Disabled][Enabled]
Intel VT for Directed I/O (VT-d)
Intel VT for Directed I/O (VT-d) [Enabled]
Allows you to enable or disable the Intel Virtualization Technology for Directed I/O.
Congurationoptions:[Disabled][Enabled]
PCI Express Global Options
TX EQ WA [Enabled]
UsespecialtableforTX_EQandvendorspeciccards.
Congurationoptions:[Disabled][Enabled]
5-34 Chapter 5: BIOS Setup
5.5.7 PCH Configuration
PCH Devices
PCI-E ASPM Support (Global) [L1 Only]
This option enables or disables the ASPM support for all downstream devices.
Congurationoptions:[Disabled][L1Only]
DeepSx Power Policies [Disabled]
AllowsyoutoconguretheDeepSxModeconguration.
Congurationoptions:[Disabled][EnabledinS5][EnabledinS4andS5]
PCI Express Configuration
ASUS TS500-E8-PS4 V2 5-35
PCH DMI ASPM [Enabled]
AllowsyoutocongurethePCHDMIASPM.
Congurationoptions:[Disabled][Enabled]
PCI Express Root Port 1 to Port 8
AllowsyoutocongurethePCIExpressRootportsettings.
PCIE ASMP [DisableASPM]
Allows you to configure the PCH DMI ASPM.
Congurationoptions:[DisableASPM][ASPML0s][ASPML1][ASPM
L0sL1][ASPMAuto]
PCH sSATA Configuration
sSATA Controller [Enabled]
Allows you to enable or disable the sSATA Controller.
Congurationoptions:[Disabled][Enabled]
Configure sSATA as [AHCI]
AllowsyoutoidentifytheSATAportisconnectedtoSolidStateDriveorHardDiskDrive.
Congurationoptions:[IDE][AHCI][RAID]
SATA Mode options
SATA LED locate [Enabled]
Ifenabled,LED/SGPIOhardwareisattached.
Congurationoptions:[Disabled][Enabled]
Support Aggressive Link Power Management [Enabled]
AllowsyoutoenableordisabletheSuportAggressiveLinkPower(SALP)Management.
Congurationoptions:[Disabled][Enabled]
5-36 Chapter 5: BIOS Setup
SATA Port 1 / SATA Port 2 / SATA Port 3 / SATA Port 4
Port 1 / Port 2 / Port 3 / Port 4
Allows you to enable or disable the SATA port
Congurationoptions:[Disabled][Enabled]
PCH SATA Configuration
SATA Controller [Enabled]
Allows you to enable or disable the SATA Controller.
Congurationoptions:[Disabled][Enabled]
Configure SATA as [AHCI]
AllowsyoutoidentifytheSATAportisconnectedtoSolidStateDriveorHardDiskDrive.
Congurationoptions:[IDE][AHCI][RAID]
Support Aggressive Link Power Management [Enabled]
AllowsyoutoenableordisabletheSuportAggressiveLinkPower(SALP)Management.
Congurationoptions:[Disabled][Enabled]
SATA Port 1~6
Port 1 / Port 2 / Port 3 / Port 4 / Port 5 / Port 6 [Enabled]
Allows you to enable or disable the SATA port
Congurationoptions:[Disabled][Enabled]
USB Configuration
xHCI Mode [Auto]
Allows you to enable or disable the mode of operation of xHCI controller.
Congurationoptions:[Auto][Disabled][Enabled]
ASUS TS500-E8-PS4 V2 5-37
USB Ports Per-Port Disable Control [Disabled]
AllowsyoutocontroleachoftheUSBports1to8disabling.
Congurationoptions:[Disabled][Enabled]
The following items appears only when the USB Ports Per‑Port Disable Control is set to
[Enabled].
USB Port #1 / #2 / #3 / #4 / #5 / #6 / #7 / #8 [Enabled]
Congurationoptions:[Disabled][Enabled]
USB 3.0 Port #1 / #2 / #3 / #4 [Enabled]
Congurationoptions:[Disabled][Enabled]
Platform Thermal Configuration
PCH Thermal Device [Auto]
Allows you to enable or disable the PCH Thermal Device (D31:F6).
Congurationoptions:[Auto][Disabled][Enabled]
5-38 Chapter 5: BIOS Setup
5.5.8 Miscellaneous Configuration
Active Video [Offboard Device]
Allows you to select the video type.
Congurationoptions:[OnboardDevice][OffboardDevice]
5.5.9 Server ME Configuration
Displays the Server ME Technology parameters on your system.
Alert Enable Lock [Disabled]
AllowsyoutolockallAlertEnablesettings.
Congurationoptions:[Disabled][Enabled]
ASUS TS500-E8-PS4 V2 5-39
5.5.10 Runtime Error Logging Support
Runtime Error Logging
Whea Support [Disabled]
ThisitemallowsyoutoenableordisabletheWHEAsupport.
Congurationoptions:[Disabled][Enabled]
5.6 Server Mgmt menu
The Server Management menu displays the server management status and allows you to
change the settings.
OS Watchdog Timer [Disabled]
This item allows you to start a BIOS timer which can only be shut off by Intel Management
Software after the OS loads.
Congurationoptions:[Disabled][Enabled]
ThefollowingitemsiscongurableonlywhentheOSWatchdogTimerissetto[Enabled].
5-40 Chapter 5: BIOS Setup
OS Wtd Timer Timeout [10 minutes]
AllowsyoutocongurethelengthfotheOSBootWatchdogTimer.
Congurationoptions:[5minutes][10minutes][15minutes][20minutes]
OS Wtd Timer Policy [Reset]
ThisitemallowsyoutocongurethehowthesystemshouldrespondiftheOSBootWatch
Timer expires.
Congurationoptions:[DoNothing][Reset][PowerDown]
Serial Mux [Disabled]
ThisitemallowsyoutoenableordisableSerialMuxconguration.
Congurationoptions:[Disabled][Enabled]
System Event Log
AllowsyoutochangetheSELeventlogconguration.
SEL Components [Enabled]
Allows you to enable or disable all features of system Event Logging during boot.
Congurationoptions:[Disabled][Enabled]
• ThefollowingitemsappearsonlywhenyousetSEL Componentsto[Enabled].
• Allvalueschangedheredonottakeeffectuntilcomputerisrestarted.
Erase SEL [No]
Allows you to choose options for erasing SEL.
Congurationoptions:[No][Yes,Onnextreset][Yes,Oneveryreset]
When SEL is Full [Do Nothing]
Allows you to choose options for reactions to a full SEL.
Congurationoptions:[DoNothing][EraseImmediately]
Log EFI Status Codes [Error code]
DisabletheloggingofEFIStatusCodes,orlogonlyerrorcode,oronlyprogresscode
or,both.
Congurationoptions:[Disabled][Both][Errorcode][Progresscode]
ASUS TS500-E8-PS4 V2 5-41
Bmc network configuration
Thesub-itemsinthiscongurationallowyoutoconguretheBMCnetworkparameters.
Configuration Address source DM_LAN1/LAN1 [Previous State]
ThisitemallowsyoutocongureLANchannelparametersstatisticallyordynamically(by
BIOSorBMC).UnspeciedoptionwillnotmodifyanyBMCnetworkparametersduring
BIOS phase.
Congurationoptions:[PreviousState][Static][DynamicBmcDhcp]
[DynamicBmcNonDhcp]
View System Event Log
This item allows you to view the system event log records.
IPv6 BMC Network Configuration
ThisitemallowsyoutoconguretheparametersettingsofIPv6BMCnetwork.
IPv6 Display Full Field [Enable]
Displays the full or brief IPv6 Field.
Congurationoptions:[Disable][Enable]
IPv6 Display Full Formula [Enable]
Displays the full or brief IPv6 Formula.
Congurationoptions:[Disable][Enable]
IPv6 Display Letter Case [Upper Case]
Displays the uppercase or lowercase letters of the alphabet.
Congurationoptions:[LowerCase][UpperCase]
IPv6 BMC Lan Option [Enable]
This item allows you to enable or disable the IPv6 BMC LAN channel function.
DisablingthisitemwillnotmodifyanyBMCnetworkduringBIOSphase.
Congurationoptions:[Disable][Enable]
5-42 Chapter 5: BIOS Setup
IPv6 BMC LAN IP Address source [Previous State]
SelecttocongureLANchannelparametersstaticallyordynamically(byBIOSor
BMC).
Congurationoptions:[PreviousState][Static][Dynamic-ObtainedbyBMCrunning
DHCP]
The following items appear only when you set IP BMC Lan IP Address Sourceto[Static].
IPv6 BMC LAN IP Address
Allows you to input IPv6 BMC Lan IP address.
IPv6 BMC LAN IP Prefix Length
Allows you to input IPv6 BMC Lan IP Prefix Length.
IPv6 BMC LAN Default Gateway
Allows you to input IPv6 BMC Lan Default Gateway.
IPv6 BMC LAN DNS Settings
Allows you to enter IPv6 BMC LAN DNS Settings.
IPv6 BMC LAN Link IP Address
AllowsyoutoenterIPv6BMCLANLinkIPaddress.
IPv6 BMC LAN Link IP Prefix Length
Allows you to input IPv6 BMC LanLinkIPPrexLength.
IPv6 BMC Lan Option [Enable]
This item allows you to enavle IPv6 BMC LAN channel function. Disabling this option will not
modifyanyBMCnetworkduringBIOSphase.
ASUS TS500-E8-PS4 V2 5-43
The following item appears only when you set IP BMC Lan Optionto[Enable].
IPv6 BMC LAN IP Address Source [Previous State]
SelecttocongureLANchannelparametersstaticallyordynamically(byBIOSor
BMC).
Congurationoptions:[PreviousState][Static][Dynamic-ObtainedbyBMCrunning
DHCP]
The following items appear only when you set IP BMC Lan IP Address Sourceto[Static].
IPv6 BMC LAN IP Address
Allows you to input IPv6 BMC Lan IP address.
IPv6 BMC LAN IP Prefix Length
Allows you to input IPv6 BMC Lan IP Prefix Length.
IPv6 BMC LAN Default Gateway
Allows you to input IPv6 BMC Lan Default Gateway.
IPv6 BMC LAN DNS Settings
Allows you to enter IPv6 BMC LAN DNS Settings.
IPv6 BMC LAN Link IP Address
AllowsyoutoenterIPv6BMCLANLinkIPaddress.
IPv6 BMC LAN Link IP Prefix Length
Allows you to input IPv6 BMC LanLinkIPPrexLength.
5-44 Chapter 5: BIOS Setup
5.7 Event Logs menu
The Event Logs menu items allow you to change the event log settings and view the system
event logs.
5.7.1 Change Smbios Event Log Settings
Press<Enter>tochangetheSmbiosEventLogconguration.
Enabling/Disabling Options
Smbios Event Log [Enabled]
Change this to enable or disable all features of Smbios Event Logging during boot.
Congurationoptions:[Disabled][Enabled]
Erasing Settings
Erase Event Log [No]
Choose options for erasing Smbios Event Log. Erasing is done prior to any logging activation
duringreset.Congurationoptions:[No][Yes,Nextreset][Yes,Everyreset]
When Log is Full [Do Nothing]
AllowsyoutochooseoptionsforreactionstoafullSmbiosEventLog.Congurationoptions:
[DoNothing][EraseImmediately]
Allvalueschangedheredonottakeeffectuntilcomputerisrestarted.
ASUS TS500-E8-PS4 V2 5-45
Smbios Event Log Standard Settings
Log System Boot Event [Disabled]
Allowsyoutochooseoptionstoenable/disableloggingofSystembootevent.Conguration
options:[Enabled][Disabled]
MECI [1]
Mutiple Event Count Increment (MECI). The number of occurrences of a duplicate event that
mustpassbeforethemultiplt-eventcounterassociatedwiththelogentryisupdated,specied
as a numeric value in the range 1 to 255.
METW [60]
MutipleEventTimeWindows(METW).Thenumberofminuteswhichmustpassbetween
duplicatelogentrieswhichutilizeamultiple-eventcounter.Thevaluerangesfrom0to99
minutes.
Custom Option
Log OEM Codes [Enabled]
Enable or disable the logging of EFI Status Codes as OEM Codes (if not already converted to
legacy).Congurationoptions:[Disabled][Enabled]
Convert OEM Codes [Disabled]
Enable or disable the converting of EFI Status Codes to Standard Smbios Types (Not all may
be translated).
Congurationoptions:[Disabled][Enabled]
5.7.2 View Smbios Event Log
Press <Enter> to view all smbios event logs.
5-46 Chapter 5: BIOS Setup
5.8 Monitor menu
TheMonitormenudisplaysthesystemtemperature/powerstatus,andallowsyoutochange
the fan settings.
Scroll down to view the other items
CPU1/2 Temperature [xxx°C/xxx°F]
The onboard hardware monitor automatically detects and displays the CPU temperatures.
CPU FAN1/2 Speed; FRNT FAN1–5 Speed; REAR FAN1/2 Speed
[xxxx RPM] or [N/A]
TheonboardhardwaremonitorautomaticallydetectsanddisplaysthespeedofCPUfans,
frontfans,andrearfaninrotationsperminute(RPM).Ifthefanisnotconnectedtothe
motherboard,theeldshowsN/A.
VCCIO, VCORE1/2 Voltage, +VDDQ_AB_CPU1 Voltage, +VDDQ_CD_CPU1
Voltage, +VDDQ_EF_CPU2 Voltage, +VDDQ_GH_CPU2 Voltage, +5VSB
Voltage, +5V Voltage, +12V Voltage, +3.3V Voltage, VBAT Voltage, +3.3VSB
Voltage
The onboard hardware monitor automatically detects the voltage output through the onboard
voltage regulators.
CPU FAN1&2 FRNT FAN1 mode [Generic Mode]
AllowsyoutoconguretheASUSSmartFanfeaturethatsmartlyadjuststhefanspeedsfor
moreefcientsystemoperation.
Congurationoptions:[GenericMode][HighSpeedMode][FullSpeedMode][ManualMode]
Duty % [50]
ThisitemappearsonlywhenCPUFAN1&2FRNTFAN1modeissetto[ManualMode].
Thisitemallowsyoutocongurethefandutysettingfrom10%to100%.
FRNT FAN2&3/4&5; REAR FAN1&2 mode [Generic Mode]
AllowsyoutoconguretheASUSSmartFanfeaturethatsmartlyadjuststhefanspeedsfor
moreefcientsystemoperation.
Congurationoptions:[GenericMode][HighSpeedMode][FullSpeedMode][ManualMode]
ASUS TS500-E8-PS4 V2 5-47
5.9 Security menu
This menu allows a new password to be created or a current password to be cchanged. The
menualsoenablesordisablestheSecureBootstateandletstheuserconguretheSystem
Mode state.
Administrator Password
To set an administrator password:
1. Select the Administrator Password item and press <Enter>.
2. FromtheCreateNewPasswordbox,keyinapassword,thenpress<Enter>.
3. Conrmthepasswordwhenprompted.
To change an administrator password:
1. Select the Administrator Password item and press <Enter>.
2. FromtheEnterCurrentPasswordbox,keyinthecurrentpassword,thenpress
<Enter>.
3. FromtheCreateNewPasswordbox,keyinanewpassword,thenpress<Enter>.
4. Conrmthepasswordwhenprompted.
Tocleartheadministratorpassword,followthesamestepsasinchanginganadministrator
password,butpress<Enter>whenpromptedtocreate/conrmthepassword.
5-48 Chapter 5: BIOS Setup
User Password
To set a user password:
1. Select the User Password item and press <Enter>.
2. FromtheCreateNewPasswordbox,keyinapassword,thenpress<Enter>.
3. Conrmthepasswordwhenprompted.
To change a user password:
1. Select the User Password item and press <Enter>.
2. FromtheEnterCurrentPasswordbox,keyinthecurrentpassword,thenpress
<Enter>.
3. FromtheCreateNewPasswordbox,keyinanewpassword,thenpress<Enter>.
4. Conrmthepasswordwhenprompted.
To clear a user password:
1. Select the Clear User Password item and press <Enter>.
2. Select YesfromtheWarningmessagewindowthenpress<Enter>.
Secure Boot Menu
This item allows you to customize the Secure Boot settings.
Secure Boot [Disabled]
Secure Boot can be enabled if the system is running in User mode with enrolled
platformKey(EPK)oriftheCSMfunctionisdisabled.
Congurationoptions:[Disabled][Enabled]
Secure Boot Mode [Custom]
Allows you to set the Secure Boot selector.
Congurationoptions:[Custom][Standard]
ASUS TS500-E8-PS4 V2 5-49
Key Management
ThisitemonlyappearswhentheitemSecureBootModeissetto[Custom].The
KeyManagementitemallowsyoutomodifySecureBootvariablesandsetKey
Management page.
Default Key Provision [Disabled]
Congurationoptions:[Disabled][Enabled]
Enroll All Factory Default Keys
ThisitemwillaskyouifyouwanttoInstallFactoryDefaultsecurekeys.SelectYesif
youwanttoloadthedefaultsecurekeys,otherwiseselectNo.
Save All Secure Boot Variables
Thisitemwillaskyouifyouwanttosaveallsecurebootvariables.SelectYesifyou
wanttosaveallsecurebootvariables,otherwiseselectNo.
Platform Key (PK) / Key Exchange Key (KEK) / Authorized Signatures (DB) / Authorized
TimeStamps (DBT) / Forbidden Signatures (DBX)
Congurationoptions:[Delete][SetNew][Append]
Configuration options: [Set New] [Delete] [Append]
5-50 Chapter 5: BIOS Setup
Setup Prompt Timeout [xx]
Usethe<+>and<->keystoadjustthenumberofsecondstowaitforsetupactivationkey.
Bootup NumLock State [On]
Allowsyoutoselectthepower-onstatefortheNumLock.
Congurationoptions:[Off][On]
Boot Logo Display [Auto]
Allows you to enable or disable the full screen logo display feature.
Congurationoptions:[Auto][FullScreen][Disabled]
POST Report [5 sec]
AllowsyoutosetthedesiredPOSTReportwaitingtimefrom1to10seconds.
Congurationoptions:[1sec]~[10sec][UntilPressESC]
Chassis Intrusion [Warning]
Allows you to set an action when chassis intrusion has occured.
Congurationoptions:[Warning][Halt]
Boot Option Priorities
These items specify the boot device priority sequence from the available devices. The
number of device items that appears on the screen depends on the number of devices
installed in the system.
5.10 Boot menu
The Boot menu items allow you to change the system boot options.
ASUS TS500-E8-PS4 V2 5-51
• Toselectthebootdeviceduringsystemstartup,press<F8>whenASUSLogo
appears.
• ToaccessWindowsOSinSafeMode,pleasepress<F8>afterPOST.
Set the booting order of network devices.
Boot Option #1/#2 [SATA P2: ASUS ...]
Congurationoptions:[SATAP2:ASUS...][SATAP3:WDCWD80...]
[AMIVirtualFloppy...][IBAGESlot0700v...]
CD/DVD ROM Drive BBS Priorities
Hard Drive BBS Priorities / Network Device BBS Priorities
These items appear only when you connect SATA ODD or hard drive to the SATA ports and
allow you to set the booting order of the SATA devices.
5.11 Tool menu
TheToolmenuitemsallowyoutocongureoptionsforspecialfunctions.Selectanitemthen
press <Enter> to display the submenu.
ASUS EZ Flash
Allows you to run ASUS EZ Flash BIOS ROM Utility when you press <Enter>. Refer to the
ASUS EZ Flash Utility section for details.
5-52 Chapter 5: BIOS Setup
Pressing <Esc> does not immediately exit this menu. Select one of the options from this
menuor<F10>fromthelegendbartoexit.
5.12 Exit menu
The Exit menu items allow you to save or discard your changes to the BIOS items.
Save Changes & Reset
Exit System setup after saving the changes.
Discard Changes & Exit
Exit System setup without saving any changes.
Save Changes & Reset
Reset the system setup after saving the changes.
Discard Changes & Reset
Reset system setup without saving any changes.
Save Options
Save Changes
Save changes done so far to any of the setup options.
Discard Changes
Discard changes done so far to any of the setup options.
ASUS TS500-E8-PS4 V2 5-53
Restore Defaults
Restore/load default values for all the setup options.
Save as User Defaults
Save the changes done so far as User Defaults.
Restore User Defaults
Restore the User Defaults to all the setup options.
Boot Override
These items displays the available devices. The device items that appears on the screen
dependsonthenumberofdevicesinstalledinthesystem.Clickanitemtostartbootingfrom
the selected device.
Launch EFI Shell from filesystem device
AttemptstolaunchEFIShellapplication(shellx64.e)fromoneoftheavailablelesystem
devices.
5-54 Chapter 5: BIOS Setup
6
RAID Conguration
This chapter provides instructions for setting up, creating, and
conguring RAID sets using the available utilities.
Chapter 6: RAID Conguration
6-2 Chapter 6: RAID Conguration
6.1 Setting up RAID
The motherboard supports the following SATA RAID solutions:
• LSI MegaRAID software RAID Configuration Utility with RAID 0, RAID 1, and RAID
10 support (for both Linux and Windows OS).
• Intel® Rapid Storage Technology enterprise Option ROM Utility with RAID 0, RAID 1,
RAID 10, and RAID 5 support (for Windows OS only).
6.1.1 RAID definitions
RAID 0
(Data striping)
optimizes two identical hard disk drives to read and write data in
parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a
sustained data transfer rate, double that of a single disk alone, thus improving data access
and storage. Use of two new identical hard disk drives is required for this setup.
RAID 1
(Data mirroring)
copies and maintains an identical image of data from one drive to a
second drive. If one drive fails, the disk array management software directs all applications
to the surviving drive as it contains a complete copy of the data in the other drive. This RAID
conguration provides data protection and increases fault tolerance to the entire system. Use
two new drives or use an existing drive and a new drive for this setup. The new drive must be
of the same size or larger than the existing drive.
RAID 10 is data striping and data mirroring combined without parity (redundancy data) having
to be calculated and written. With the RAID 10 conguration you get all the benets of both
RAID 0 and RAID 1 congurations. Use four new hard disk drives or use an existing drive and
three new drives for this setup.
RAID 5 stripes both data and parity information across three or more hard disk drives. Among
the advantages of RAID 5 conguration include better HDD performance, fault tolerance, and
higher storage capacity. The RAID 5 conguration is best suited for transaction processing,
relational database applications, enterprise resource planning, and other business systems.
Use a minimum of three identical hard disk drives for this setup.
• If you want to boot the system from a hard disk drive included in a created RAID set,
copy rst the RAID driver from the support DVD to a oppy disk before you install an
operating system to the selected hard disk drive.
• Please refer to chapter 2 for how to select the RAID conguration utility. Move the
jumper to choose between LSI MegaRAID and Intel® Rapid RAID.
6-3
ASUS TS500-E8-PS4 V2
6.1.3 Setting the RAID item in BIOS
You must set the RAID item in the BIOS Setup before you can create a RAID set from SATA
hard disk drives attached to the SATA connectors supported by Intel® C612 chipset.
To do this:
1. Enter the BIOS Setup during POST.
2. Go to the Advanced Menu > PCH SATA Configuration, then press <Enter>.
3. Set SATA Mode to [RAID Mode]
4. Press <F10> to save your changes and exit the BIOS Setup.
Refer to Chapter 4 for details on entering and navigating through the BIOS Setup.
6.1.4 RAID configuration utilities
Depending on the RAID connectors that you use, you can create a RAID set using the
utilities embedded in each RAID controller. For example, use the LSI MegaRAID Software
Configuration Utility or the Intel® Rapid Storage Technology if you installed Serial ATA
hard disk drives on the Serial ATA connectors supported by the Intel® C612 chipset.
Refer to the succeeding section for details on how to use the RAID conguration utility.
6.1.2 Installing hard disk drives
The motherboard supports Serial ATA for RAID set conguration. For optimal performance,
install identical drives of the same model and capacity when creating a disk array.
To install the SATA hard disks for RAID conguration:
1. Install the SATA hard disks into the drive bays following the instructions in the system
user guide.
2. Connect a SATA signal cable to the signal connector at the back of each drive and to
the SATA connector on the motherboard.
3. Connect a SATA power cable to the power connector on each drive.
6-4 Chapter 6: RAID Conguration
3. The utility main window appears. Use the arrow keys to select an option from the
Management Menu and then press <Enter>. Refer to the Management Menu
descriptions on the next page.
At the bottom of the screen is the legend box. The keys on the legend box allow you
to navigate through the setup menu options or execute commands. The keys on the
legend box vary according to the menu level.
6.2 LSI Software RAID Configuration Utility (Z10PA-D8
only)
The LSI MegaRAID software RAID conguration utility allows you to create RAID 0,
RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors
supported by the motherboard southbridge chip.
To enter the LSI MegaRAID software RAID conguration utility:
1. Turn on the system after installing all the SATA hard disk drives.
2. During POST, the LSI MegaRAID software RAID conguration utility automatically
detects the installed SATA hard disk drives and displays any existing RAID set(s).
Press <Ctrl> + <M> to enter the utility.
• The LSI MegaRAID software RAID conguration utility automatically congures to
RAID 1 when the SATA to RAID Mode is enabled.
• The RAID setup screens shown in this section are for reference only and may not
exactly match the items on your screen due to the controller version difference.
• When you create RAID sets with the LSI MegaRAID software RAID conguration
utility, the boot priority of the SATA optical drive has to be manually adjusted.
Otherwise, the system will not boot from the connected SATA ODD.
LSI MegaRAID Software RAID BIOS Version A.10 09231523R
LSI SATA RAID Found at PCI Bus No:00 Dev No:1F
Device present at Port 0 ST3160812AS 152114MB
Device present at Port 1 ST3160812AS 152114MB
Device present at Port 2 ST3160812AS 152114MB
Device present at Port 3 ST3160812AS 152114MB
Press Ctrl-M or Enter to run LSI Software RAID Setup Utility.
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Configure VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
6-5
ASUS TS500-E8-PS4 V2
6.2.1 Creating a RAID set
The LSI Software RAID Conguration Utility allows you to create a RAID 0, RAID 1, or RAID
10 set using two types of congurations: Easy and New.
In Easy Configuration, the virtual drive parameters are set automatically.
In New Configuration, you manually set the virtual drive parameters.
Using Easy Configuration
To create a RAID set using the Easy Configuration option:
1. From the Management Menu, select Configure > Easy Configuration, and then press
<Enter>.
Menu Description
Congure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy
Conguration or the New Conguration command. This menu also
allows you to view, add, or clear RAID congurations or select the
boot drive
Initialize Allows you to initialize the virtual drives of a created RAID set
Objects Allows you to initialize virtual drives or change the virtual drive
parameters
Rebuild Allows you to rebuild failed drives
Check Consistency Allows you to check the data consistency of the virtual drives of a
created RAID set
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Defines Physical Arrays. An Array Will Automatically Become A VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
6-6 Chapter 6: RAID Conguration
3. Select all the drives required for the RAID set, and then press <F10> to congure array
setting.
4. Press <Space> to select the congurable array.
2. The ARRAY SELECTION MENU displays the available drives connected to the SATA
ports. Use the up/down arrow keys to select the drives you want to include in the RAID
set, and then press <Space>. When selected, the drive indicator changes from READY
to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number.
• The information of the selected hard disk drive displays at the bottom of the screen.
• You need at least two identical hard disk drives when creating a RAID 1 set.
• You need at least four identical hard disk drives when creating a RAID 10 set.
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Virtual Drives,F4-HSP
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Port # 2 DISK 74.74GB HDS728080PLA380 05.01C05
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Cursor Keys, SPACE-(De)Select F2-Chidinfo F3-SlotInfo F10-Configure Esc-Quit
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Select Configurable Array(s)
A-0
SPAN-1
6-7
ASUS TS500-E8-PS4 V2
5. Press <F10> again, the virtual drive information appears including a Virtual Drive
menu that allows you to change the virtual drive parameters.
6. Select RAID from the Virtual Drive sub-menu, and then press <Enter>.
7. Select the RAID level from the menu, and then press <Enter>.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Choose RAID Level For This VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
RAID = 1
Units= MB
Size = 152146MB
DWC = OFF
RA = On
Accept
SPAN = NO
Virtual Drive 0
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Choose RAID Level For This VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
RAID 0
RAID 1
RAID Level
RAID = 1
Units= MB
Size = 152146MB
DWC = OFF
RA = On
Accept
SPAN = NO
Virtual Drive 0
6-8 Chapter 6: RAID Conguration
8. Select Units from the Virtual Drive sub-menu, and then press <Enter>.
9. Select the units for virtual drive size from the menu, and then press <Enter>.
10. When creating a RAID 1 or a RAID 10 set, select DWC from the Virtual Drive menu,
and then press <Enter>.
When creating a RAID 0 set, proceed to step 12.
11. Select On to enable the Disk Write Cache setting, and then press <Enter>.
Enabling DWC can improve the performance, but with the risk of data loss.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select Units For VD Size
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
MB
GB
TB
Select Units For VD Size
RAID = 1
Units= MB
Size = 152146MB
DWC = OFF
RA = On
Accept
SPAN = NO
Virtual Drive 0
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Disk Write Cache Setting of VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
Off
On
Change DWC
RAID = 1
Units= MB
Size = 152146MB
DWC = OFF
RA = On
Accept
SPAN = NO
Virtual Drive 0
6-9
ASUS TS500-E8-PS4 V2
12. When nished setting the selected virtual drive conguration, select Accept from the
menu, and then press <Enter>.
13. Follow step 2 to 12 to congure additional virtual drives.
14. Press <Esc> to nish RAID conguration. When prompted to save conguration, select
Yes from the menu, and then press <Enter>.
Cursor Keys, SPACE-(De) Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Accept This VD Configuration And Go To Next VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
RAID = 1
Units= MB
Size = 152146MB
DWC = OFF
RA = On
Accept
SPAN = NO
Virtual Drive 0
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select Yes Or No
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu Yes
No
Save Configuration?
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
6-10 Chapter 6: RAID Conguration
Using New Configuration
When a RAID set already exists, using the New Configuration command erases the
existing RAID conguration data. If you do not want to delete the existing RAID set, use the
View/Add Configuration command to view or create another RAID conguration.
To create a RAID set using the New Configuration option
1. From the Management Menu, select Configure > New Configuration, and then press
<Enter>.
2. Follow step 2 to 9 of the previous section: Using Easy Configuration.
3. Select Size from the Virtual Drive menu, and then press <Enter>.
4. Key-in the desired virtual drive size, and then press <Enter>.
5. Follow step 10 to 14 of the previous section: Using Easy Configuration to create the
RAID set.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Clear Existing Configuration And Start A New Configuration
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Enter VD Size:
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
RAID = 1
Units= MB
Size = 152146MB
DWC = OFF
RA = On
Accept
SPAN = NO
Virtual Drive 0
Enter VD Size: 152146_
6-11
ASUS TS500-E8-PS4 V2
6.2.2 Adding or viewing a RAID configuration
You can add a new RAID conguration or view an existing conguration using the View/Add
Configuration command.
Adding a new RAID configuration
To add a new RAID conguration:
1. From the Management Menu, select Configure > View/Add Configuration, and then
press <Enter>.
2. The ARRAY SELECTION MENU displays the available drives connected to the SATA
ports. Select the drive(s) you want to include in the RAID set, then press <Space>.
When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X
is the array number, and Y is the drive number.
The information of the selected hard disk drive displays at the bottom of the screen.
3. Follow step 3 to 12 of section 6.2.1 Creating a RAID set: Using Easy Configuration
to add a new RAID set.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
View/Add to The Existing Configuration
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Virtual Drives,F4-HSP
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Port # 2 DISK 77247MB HDS72808PLA380 PF20A60A
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
View/Add Configuration - ARRAY SELECTION MENU
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
2
3
PORT #
6-12 Chapter 6: RAID Conguration
6.2.3 Initializing the virtual drives
After creating the RAID set(s), you must initialize the virtual drives. You may initialize the
virtual drives of a RAID set(s) using the Initialize or Objects command on the Management
Menu.
Using the Initialize command
To initialize the virtual drive using the Initialize command
1. From the Management Menu, select Initialize, and then press <Enter>.
2. The screen displays the available RAID set(s) and prompts you to select the virtual
drive to initialize. Use the arrow keys to select the virtual drive from the Virtual Drive
selection, and then press <Space>.
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Initialize VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
6-13
ASUS TS500-E8-PS4 V2
3. Press <F10> to start initialization. When prompted, select Yes from the Initialize?
dialog box, and then press <Enter>.
Initializing a virtual drive erases all data on the drive.
4. A progress bar appears on screen. If desired, press <Esc> to abort initialization. When
initialization is completed, press <Esc>.
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Init Will Destroy Data On Selected VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
Yes
No
Initialize?
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
Init of VD Is In Process
VD 0 Initialization Complete. Press Esc..
100% Completed
6-14 Chapter 6: RAID Conguration
Using the Objects command
To initialize the virtual drives using the Objects command
1. From the Management Menu, select Objects > Virtual Drive, and then press
<Enter>.
2. Select the virtual drive to initialize from the Virtual Drives sub-menu, and then press
<Enter>.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Change VD Parameters
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Adapter
Virtual Drive
Physical Drive
Objects
Press ENTER To Select A VD, <Del> To Delete A VD
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Adapter
Virtual Drive
Physical Drive
Objects
Virtual Drive 0
Virtual Drive(1)
6-15
ASUS TS500-E8-PS4 V2
3. Select Initialize from the pop-up menu, and then press <Enter> to start initialization.
4. When prompted, press the <Space> to select Yes from the Initialize? dialog box, and
then press <Enter>.
5. A progress bar appears on screen. If desired, press <Esc> to abort initialization. When
initialization is completed, press <Esc>.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Initialize VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Adapter
Virtual Drive
Physical Drive
Objects
Virtual Drive 0
Virtual Drive(1)
Initialize
Check Consistency
View/Update Parameters
Virtual Drive(0)
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Adapter
Virtual Drive
Physical Drive
Objects
Virtual Drive 0
Virtual Drive(1)
Initialize
Check Consistency
View/Update Parameters
Virtual Drive(0)
Yes
No
Initialize?
Init Will Destroy Data On Selected VD(s)
6-16 Chapter 6: RAID Conguration
6.2.4 Rebuilding failed drives
You can manually rebuild failed hard disk drives using the Rebuild command in the
Management Menu.
To rebuild a failed hard disk drive
1. From the Management Menu, select Rebuild, and then press <Enter>.
2. The PHYSICAL DRIVES SELECTION MENU displays the available drives connected
to the SATA ports. Select the drive you want to rebuild, and then press <Space>.
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Rebuild VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Port # 1 DISK 77247MB HDS72808PLA380 PF20A60A
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
REBUILD - PHYSICAL DRIVES SELECTION MENU
ONLIN A00-00
FAIL A00-01
0
1
PORT #
6-17
ASUS TS500-E8-PS4 V2
3. After selecting the drive to rebuild, press <F10>. When prompted, press <Y> to rebuild
the drive.
4. When rebuild is complete, press any key to continue.
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Port # 1 DISK 77247MB HDS72808PLA380 PF20A60A
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
REBUILD - PHYSICAL DRIVES SELECTION MENU
ONLIN A00-00
FAIL A00-01
0
1
PORT #
Rebuilding of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)?
6-18 Chapter 6: RAID Conguration
6.2.5 Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual drive. The
utility can automatically detect and/or detect and correct any differences in data redundancy
depending on the selected option in the Objects > Adapter menu.
The Check Consistency command is available only for virtual drives included in a RAID 1
or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the Check Consistency command
1. From the Management Menu, select Check Consistency, and then press <Enter>.
2. The screen displays the available RAID set(s) and prompts you to select the virtual
drive to check. Press <Space> to select the virtual drive from the Virtual Drive sub-
menu, and then press <F10>.
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
CC of VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
6-19
ASUS TS500-E8-PS4 V2
3. When prompted, use the arrow keys to select Yes from the Consistency Check?
dialog box, and then press <Enter>.
A progress bar appears on screen.
4. While checking the disk consistency, press <Esc> to display the following options.
• Stop - Stops the consistency check. The utility stores the percentage of
disk checked, and when you restart checking, it continues from the
last percentage completed rather than from zero percent.
• Continue - Continues the consistency check.
• Abort - Aborts the consistency check. When you restart checking, it
continues from zero percent.
5. When checking is complete, press any key to continue.
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
Yes
No
Consistency Check?
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
The Data On The Drives Is Inconsistency. Repair Done!
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives
CC Under Process
VD 0 Consistency Check. Press Esc to Abort.
85% Completed
6-20 Chapter 6: RAID Conguration
Using the Objects command
To check data consistency using the Objects command
1. From the Management Menu, select Objects, and then select Virtual Drive from the
sub-menu.
2. Use the arrow keys to select the virtual drive you want to check, and then press
<Enter>.
3. Select Check Consistency from the pop-up menu, and then press <Enter>.
4. When prompted, use the arrow keys to select Yes from the dialog box to check the
drive.
5. When checking is complete, press any key to continue.
6-21
ASUS TS500-E8-PS4 V2
6.2.6 Deleting a RAID configuration
To delete a RAID conguration
1. From the Management Menu, select Configure > Clear Configuration, and then
press <Enter>.
2. When prompted, use the arrow keys to select Yes from the Clear Configuration?
dialog box, and then press <Enter>.
The utility clears all the current array(s).
3. Press any key to continue.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Clear Existing Configuration
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Clear Existing Configuration
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
Yes
No
Clear Configuration?
6-22 Chapter 6: RAID Conguration
6.2.7 Selecting the boot drive from a RAID set
You must have created a new RAID conguration before you can select the boot drive from a
RAID set. See section 6.2.1 Creating a RAID set: Using New Configuration for details.
To select the boot drive from a RAID set
1. From the Management Menu, select Configure > Select Boot Drive, and then press
<Enter>.
2. When prompted, use the arrow keys to select the bootable virtual drive from the list,
then press <Enter>.
3. The virtual drive is selected as boot drive. Press any key to continue.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select A Boot VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Select A Boot VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Configuration Menu
Boot Drive 0
Bootable VDs(1): Current Boot VD(0)
6-23
ASUS TS500-E8-PS4 V2
6.2.8 Enabling WriteCache
You may manually enable the RAID controller’s WriteCache option after creating a RAID set
to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs while
transmitting or exchanging data among the drives.
The WriteCache function is recommended for RAID 1 and RAID 10 sets.
To enable WriteCache
1. From the Management Menu, select Objects > Adapter, select an existing adapter,
and then press <Enter> to display the adapter properties.
2. Select Disk WC, and then press <Enter> to turn on the option.
5. When nished, press any key to continue.
3. From the Management Menu, select Objects > Virtual Drive, select an existing
adapter and press <Enter>. Select View/Update Parameters and press <Enter> to
display the adapter properties.
4. Select Disk WC, and then press <Enter> to turn on the option.
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Disk Write Cache - Off(Write Through or On(Write Back)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Adapter
Virtual Drive
Physical Drive
Objects
Rebuild Rate = 30
Chk Const Rate = 30
FGI Rate = 30
BGI Rate = 30
Disk WC = Off
Read Ahead = On
Bios State = Enable
Cont On Error = Yes
Fast Init = Enable
Auto Rebuild = On
Auto Resume = Enable
Disk Coercion = 1GB
Factory Default
Adapter 0
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Disk Write Cache Setting of VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Adapter
Virtual Drive
Physical Drive
Objects
RAID = 0
Size = 148.580GB
Stripe Size = 64KB
#Stripes = 2
State = OPTIMAL
Spans = 1
Disk WC = On
Read Ahead = On
Virtual Drive
6-24 Chapter 6: RAID Conguration
6.3 Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM Utility
The Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM utility allows you
to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set from Serial ATA hard disk
drives that are connected to the Serial ATA connectors supported by the Southbridge.
The navigation keys at the bottom of the screen allow you to move through the menus
and select the menu options.
The RAID BIOS setup screens shown in this section are for reference only and may not
exactly match the items on your screen.
To launch the Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM utility:
1. Turn on the system.
2. During POST, press <Ctrl>+<I> to display the utility main menu.
Before you proceed, ensure that you have installed the Serial ATA hard disk drives, have
set the correct jumper settings of the motherboard, and have set the correct SATA mode in
the BIOS setup. You can refer to the Installing hard disk drives, Setting Jumpers, and
Setting the RAID mode sections in BIOS for more information.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes:
None defined.
Physical Disks:
ID Drive Model Serial # Size Type/Status(Vol ID)
0 ST3300656SS HWAS0000991753TR 279.3GB Non-RAID Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Non-RAID Disk
2 ST3300656SS 397600009846UEDY 279.3GB Non-RAID Disk
3 ST3300656SS GWC50000991756G6 279.3GB Non-RAID Disk
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
6-25
ASUS TS500-E8-PS4 V2
6.3.1 Creating a RAID set
To create a RAID set:
1. From the utility main menu, select 1. Create RAID Volume and press <Enter>.
2. Key in a name for the RAID set and press <Enter>.
3. Press the up/down arrow keys to select a RAID Level that you wish to create then
press <Enter>.
4. From the Disks item eld, press <Enter> to select the hard disk drives that you want to
include in the RAID set.
5. Use the up/down arrow keys to move the selection bar then press <Space> to select a
disk. A small triangle before the Port number marks the selected drive. Press <Enter>
when you are done.
[ESC]-Previous Menu [ENTER]-Select[ ]Change
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
[ HELP ]
Name:
RAID Level:
Disks:
Strip Size:
Capacity:
Syne:
Create Volume
Enter a unique volume name that has no special characters and is
16 characters or less.
Volume0
RAID0(Strips)
Select Disks
128KB
0.0 GB
N/A
[TAB]-Next
[ SELECT DISKS ]
Port Drive Model Serial # Size Status
0 ST3300656SS HWAS0000991753TR 279.3GB Non-RAID Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Non-RAID Disk
2 ST3300656SS 397600009846UEDY 279.3GB Non-RAID Disk
3 ST3300656SS GWC50000991756G6 279.3GB Non-RAID Disk
Select 1 Master and 1 Recovery disk to create volume.
[ ]-Prev/Next [TAB]-(M)aster [SPACE]-(R)ecovery [ENTER]-Done
6-26 Chapter 6: RAID Conguration
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0,
10 and 5 only) then press <Enter>. The available stripe size values range from 4 KB to
128 KB. The following are typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
We recommend a lower stripe size for server systems, and a higher stripe size for
multimedia computer systems used mainly for audio and video editing.
7. In the Capacity eld item, key in the RAID volume capacity that you want to use and
press <Enter>. The default value eld indicates the maximum allowed capacity.
8. Press <Enter> to start creating the RAID volume.
9. From the following warning message, press <Y> to create the RAID volume and return
to the main menu, or press <N> to go back to the CREATE VOLUME menu.
WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
Are you sure you want to create this volume? (Y/N):
6-27
ASUS TS500-E8-PS4 V2
6.3.2 Deleting a RAID set
Take caution when deleting a RAID set. You will lose all data on the hard disk drives when
you delete a RAID set.
To delete a RAID set:
1. From the utility main menu, select 2. Delete RAID Volume and press <Enter>.
2. From the Delete Volume Menu, press the up/down arrow keys to select the RAID set
you want to delete then press <Del>.
3. Press <Y> to conrm deletion of the selected RAID set and return to the utility main
menu, or press <N> to return to the DELETE VOLUME menu.
[ESC]-Previous Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ DELETE VOLUME MENU ]
[ HELP ]
Deleting a volume will reset the disks to non-RAID
WARNING: ALL DISK DATA WILL BE DELETED.
(This does not apply to Recovery volumes)
[DEL]-Delete Volume
Name Level Drives Capacity Status Bootable
Volume0 RAID0(Stripe) 2 298.0GB Normal Yes
ALL DATA IN THE VOLUME WILL BE LOST!
(This does not apply to Recovery volumes)
Are you sure you want to delete volume “Volume0”? (Y/N):
[ DELETE VOLUME VERIFICATION ]
6-28 Chapter 6: RAID Conguration
6.3.3 Resetting disks to Non-RAID
Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a
RAID volume hard disk drive deletes all internal RAID structure on the drive.
To reset a RAID set:
1. From the utility main menu, select 3. Reset Disks to Non-RAID and press <Enter>.
2. Press the up/down arrow keys to select the drive(s) or disks of the RAID set you want
to reset, then press <Space>. A small triangle before the Port number marks the
selected drive. Press <Enter> when you are done.
3. Press <Y> in the conrmation window to reset the drive(s) or press <N> to return to the
utility main menu.
Port Drive Model Serial # Size Status
0 ST3300656SS HWAS0000991753TR 279.3GB Member Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Member Disk
Select the disks that should be reset.
Resetting RAID disk will remove its RAID structures
and revert it to a non-RAID disk.
[ ]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
[ RESET RAID DATA ]
WARNING: Resetting a disk causes all data on the disk to be lost.
(This does not apply to Recovery volumes)
6-29
ASUS TS500-E8-PS4 V2
Select a destination disk with the same size as the original hard disk.
6.3.5 Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays
the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array
with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. During POST, press <Ctrl>+<I> at the prompt to enter the Intel Rapid Storage
Technology option ROM utility.
2. If there is a non-RAID SATA Hard Disk available, the utility will prompt you to rebuild
the RAID. Press the up/down arrow keys to select the destination disk then Press
<Enter> to start the rebuilding process, or press <ESC> to exit.
To exit the utility:
1. From the utility main menu, select 4. Exit then press <Enter>.
2. Press <Y> to exit or press <N> to return to the utility main menu.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XXX.GB
“Degraded” volume and disk available for rebuilding detected. Selectign
a disk initiates a rebuild. Rebuild completes in the operating system.
[ ]-Previous/Next [ENTER]-Select [ESC]-Exit
[ DEGRADED VOLUME DETECTED ]
Are you sure you want to exit? (Y/N):
[ CONFIRM EXIT ]
6.3.4 Exiting the Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM utility
6-30 Chapter 6: RAID Conguration
3. The utility immediately starts rebuilding after the disk is selected. When done, the
status of the degraded RAID volume is changed to “Rebuild”.
4. Press <Esc> to exit Intel Rapid Storage Technology and reboot the system.
5. Select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or
click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Storage
Manager utility.
6. From the View menu, select Advanced Mode to display the details of the Intel Rapid
Storage Console.
7. From the Volumes view option, select RAID volume to view the rebuilding status.
When nished, the status is changed to “Normal”.
Rebuilding the RAID with a new hard disk
If any of the SATA hard disk drives included in the RAID array failed, the system displays the
status of the RAID volume as “Degraded” during POST. You may replace the disk drive and
rebuild the RAID array.
To rebuild the RAID with a new hard disk:
1. Remove the failed SATA hard disk and install a new SATA hard disk of the same
specication into the same SATA Port.
Select a destination disk with the same size as the original hard disk.
2. Reboot the system then follow the steps in section Rebuilding the RAID with other
non-RAID disk.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes: *=Data is Encrypted
ID Name Level1 Strip Size Status Bootable
1 Volume0 RAID1(Mirror) N/A 149.0GB Rebuild Yes
Physical Devices:
Port Drive Model Serial # Size Type/Status(Vol ID)
1 ST3160812AS 9LS0F4HL 149.0GB Member Disk(0)
2 ST3160812AS 3LS0JYL8 149.0GB Member Disk(0)
Volumes with “Rebuild” status will be rebuilt within the operating system.
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
6-31
ASUS TS500-E8-PS4 V2
6.3.6 Setting the Boot array in the BIOS Setup Utility
You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-
RAID using the Intel® Rapid Storage Technology enterprise SATA Option ROM utililty.
To set the boot array in the BIOS:
Set at least one of the arrays bootable to boot from the hard disk.
1. Reboot the system and press <Del> to enter the BIOS setup utility during POST.
2. Go to the Boot menu and select the boot option priority.
3. Use up/down arrow keys to select the boot priority and press <Enter>. See the Boot
menu section of Chapter 4 for more details.
4. From the Exit menu, select Save Changes & Exit, then press <Enter>.
5. When the conrmation window appears, select Yes, then press <Enter>.
6-32 Chapter 6: RAID Conguration
6.4 Intel® Rapid Storage Technology enterprise
(Windows)
The Intel® Rapid Storage Technology enterprise allows you to create RAID 0, RAID 1, RAID
10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the
Serial ATA connectors supported by the Southbridge.
You can click Rescan to re-scan any attached hard disks.
1. Turn on the system and go to the windows desktop.
2. Click the Intel® Rapid Storage Technology enterprise icon to display the main menu.
Your storage system is congured for data protection, increased performance and
optimal data storage capacity. You can create additional volumes to further optimize
your storage system.
To enter the Intel® Rapid Storage Technology enterprise utility under Windows operating
system:
You need to manually install the Intel® Rapid Storage Technology enterprise utility on a
Windows® operating system. Please refer to the installation instructions in Chapter 6.
6-33
ASUS TS500-E8-PS4 V2
6.4.1 Creating a RAID set
To create a RAID set:
1. From the utility main menu, select Create Volume and select volume type.
2. Click Next.
3. Enter a name for the RAID set, then select the array disks.
4. Select Volume Size tab, you can drag the bar to decide the volume size.
5. Click Next.
• If you do not want to keep the data on one of the selected disks, select NO when
prompted.
• If you want to Enable volume write-back cache or Initialize volume, click
Advanced.
6-34 Chapter 6: RAID Conguration
6. Conrm the volume creation, than click Create Volume to continue.
This process could take a while depending on the number and size of the disks. You can
continue using other applications during this time.
7. Wait until the process is completed, then click OK when prompted.
You still need to partition your new volume using Windows Disk Management before
adding any data.
The RAID set is displayed in the Volumes list and you can change the settings in Volume
Properties.
6-35
ASUS TS500-E8-PS4 V2
6.4.2 Changing a Volume Type
To change the volume type in Volume Properties:
1. Click the SATA array items you want to change in Volumes eld.
2 From the Volume Properties eld, select Type:RAID 1 Change type.
We recommend a lower stripe size for server systems, and a higher stripe size for
multimedia computer systems used mainly for audio and video editing.
3. You can change the Name, Select the new volume type, and Select additional
disks to include in the new volume if needed.
4. Select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only), and click
OK. The available stripe size values range from 4 KB to 128 KB. The following are
typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
6-36 Chapter 6: RAID Conguration
6.4.3 Deleting a volume
Be cautious when deleting a volume. You will lose all data on the hard disk drives.Before
you proceed, ensure that you back up all your important data from your hard drives.
To delete a volume:
1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes eld
you want to delete.
3. Click Yes to delete the volume and return to the utility main menu, or click No to return
to the main menu.
2. Select Delete volume in Volume Properties eld. The following screen appears.
6-37
ASUS TS500-E8-PS4 V2
6.4.4 Preferences
System Preferences
Allow you to set to show the notication area icon and show system information, warning, or
errors here.
E-Mail Preferences
Allow you to set to sent e-mail of the following events:
• Storage system information
• Storage system warnings
• Storage system errors
6-38 Chapter 6: RAID Conguration
7
Driver Installation
This chapter provides the instructions for installing the
necessary drivers for different system components in both
Linux® and Windows® Operating Systems.
Chapter 7: Driver Installation
7-2 Chapter 7: Driver Installation
7.1 RAID driver installation
After creating the RAID sets for your server system, you are now ready to install an
operating system to the independent hard disk drive or bootable array. This part provides the
instructions on how to install the RAID controller drivers during OS installation.
7.1.1 Creating a RAID driver disk
The system does not include a oppy drive. You have to use a USB oppy drive when
creating a SATA RAID driver disk.
If you have created RAID sets with the LSI Software RAID conguration utility, the boot
priority of the SATA optical disk drive has to be manually adjusted. Otherwise, the system
will not boot from the connected SATA ODD.
To create a RAID driver disk in Windows® environment
1. Start Windows®.
2. Place the motherboard support DVD into the optical drive.
3. Go to the Make disk menu, and then select the type of RAID driver disk you want to
create.
4. Insert a oppy disk into the USB oppy disk drive.
5. Follow succeeding screen instructions to complete the process.
Write-protect the oppy disk to avoid computer virus infection.
To create a RAID driver disk in Red Hat® Enterprise Linux server environment
1. Insert a blank formatted high-density oppy disk to the USB oppy disk drive.
2. Type dd if=XXX.img of=/dev/fd0 to decompress the le into the oppy disk from
the following path in the support DVD:
For LSI MegaRAID Driver
\Drivers\C610 LSI RAID\Driver\makedisk\Linux
3. Eject the oppy disk.
ASUS TS500-E8-PS4 V2 7-3
7.1.2 Installing the RAID controller driver
During Windows® Server 2008 R2 OS installation
To install the RAID controller driver when installing Windows® Server 2008 R2 OS
1. Boot the computer using the Windows® Server 2008 R2 OS installation disc. Follow the
screen instructions to start installing Windows Server 2008 R2.
2. When prompted to choose a type of installation, click Custom (advanced).
3. Click Load Driver.
7-4 Chapter 7: Driver Installation
4. A message appears, reminding you to insert the installation media containing the driver
of the RAID controller driver. If you have only one optical drive installed in your system,
eject the Windows OS installation disc and replace with the motherboard Support DVD
into the optical drive. Click Browse to continue.
5. Locate the driver in the corresponding folder of the Support DVD then click OK to
continue.
6. Select the RAID controller driver you need from the list and click Next.
7. When the system nishes loading the RAID driver, replace the motherboard Support
DVD with the Windows Server installation disc. Select the drive to install Windows and
click Next.
8. Setup then proceeds with the OS installation. Follow screen instructions to continue.
ASUS TS500-E8-PS4 V2 7-5
3. Select Yes using the <Tab> key when asked if you have the driver disk, then press
<Enter>.
Main Menu
Do you have a driver disk?
Yes No
4. Insert the Red Hat® Enterprise RAID driver disk to the USB oppy disk drive, select
OK, then press <Enter>.
The drivers for the RAID card are installed to the system.
Insert Driver Disk
OK Back
Insert your driver disk into /dev/fd0
and press “OK” to continue.
Red Hat® Enterprise Linux OS 5.x
To load the LSI MegaRAID controller driver when installing Red Hat® Enterprise OS:
1. Boot the system from the Red Hat® OS installation CD.
2. At the boot: type linux dd then press <Enter>.
- To install or upgrade in graphical mode, press the <ENTER> key.
- To install or upgrade in text mode, type: linux text <ENTER>.
- Use the function keys listed below for more information.
[F1-Main] [F2-Options] [F3-General] [F4-Kernel] [F5-Rescue]
boot: linux dd
7-6 Chapter 7: Driver Installation
5. When asked if you will load additional RAID controller drivers, select No, then press
<Enter>.
More Driver Disks?
Yes No
6. Follow the onscreen instructions to nish the OS installation.
7. When the installation is completed, DO NOT click Reboot. Press <Ctrl> + <Alt> +
<F2> to switch to the command-line interface from graphic user interface.
8. Type the following commands when using a Legacy oppy.
mkdir /mnt/driver
mount /dev/fd0 /mnt/driver
cd /mnt/driver
sh replace_ahci.sh
reboot
Do you wish to load any more
driver disks?
ASUS TS500-E8-PS4 V2 7-7
3. While booting from DVD, press <ESC> to give the third party driver. Enter the following
command at the boot: Linux dd blacklist=isci blacklist=ahci nodmraid,
then press <ENTER>.
Red Hat® Enterprise Linux OS 6.x
To install the LSI MegaRAID controller driver when installing Red Hat® Enterprise OS:
1. Boot the system from the Red Hat® OS installation CD.
2. Press <Tab> to edit options.
7-8 Chapter 7: Driver Installation
4. Select Yes using the <Tab> key when asked if you have the driver disk, then press
<Enter>.
5. You have multiple devices which could serve as source for a driver disk. Choose one
you like to use and select OK, then press <Enter>.
OK Cancel
Main Menu
Yes No
Driver Disk Sou8rce
You have multiple devices which could
serve as source for a driver disk.
Which would you like to use?
sdc
sdd
sdb
sr0
Do you have a driver disk?
ASUS TS500-E8-PS4 V2 7-9
6. Insert the Red Hat® Enterprise RAID driver disk to the USB oppy disk drive, select
OK, then press <Enter>.
The drivers for the RAID card are installed to the system.
7. When asked if you will load additional RAID controller drivers, select No, then press
<Enter>.
More Driver Disks?
Yes No
Insert Driver Disk
OK Back
8. Follow the onscreen instructions to nish the OS installation.
Insert your driver disk into /dev/sdb
and press “OK” to continue.
Do you wish to load any more
driver disks?
7-10 Chapter 7: Driver Installation
Preparing the Linux Driver
Ensure that there is another computer with a Linux-based OS to create the RAID driver. When
creating the RAID driver, you may refer to the examples below which uses a 64bit SUSE Linux
system to create a 64bit RAID driver for SUSE11 sp1.
1. Copy the image le into the Linux system.
Example: megasr-15.00.0120.2012-1-sles11-ga-x86_64.img
2. Create a folder.
Example: image
3. Mount the image le into the image folder using this command format:
mount -oloop [image le name] image
Example: mount -oloop megasr-15-15.00.0120.2012-1-sles11-
ga-x86__64.img image
4. Copy the contents of the image directory, labeled as 01, into a FAT32 USB drive.
5. Rename the 01 folder to CD Image.
ASUS TS500-E8-PS4 V2 7-11
3. Press <F6>, then select Yes from the menu. Press <Enter>.
Installing SUSE 11 Linux OS
To install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise
Server OS:
1. Boot the system from the SUSE OS installation CD.
2. Use the arrow keys to select Installation from the Boot Options menu.
7-12 Chapter 7: Driver Installation
6. Select Back and follow the onscreen instructions to nish the installation.
4. Use the USB drive to provide the third-party driver during the OS installation. Type the
command brokenmodules=ahci in Boot Options eld, and press <Enter>.
5. When below screen appears, select the USB oppy disk drive (sda) as the driver
update medium. Select OK, then press <Enter>.
Please choose the Driver Update medium.
sda: USB Floppy
other device
OK Back
ASUS TS500-E8-PS4 V2 7-13
7.2 Management applications and utilities installation
When you place the support DVD into the optical drive, the DVD automatically displays the
main screen if Autorun is enabled in your computer. By default, the Drivers tab is displayed.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
7.3 Running the Support DVD
1. The contents of the support DVD are subject to change at any time without notice.
Visit the ASUS website (www.asus.com) for the latest updates on software and
utilities.
2. The support DVD is supported on Windows® Server 2008 R2 and Windows® Server
2012.
The support DVD that is bundled with your motherboard contains drivers, management
applications, and utilities that you can install to maximize the features of your motherboard.
The main screen of the Support DVD contains the following tabs:
1. Drivers
2. Utilities
3. MakeDisk
4. Manual
5. Contact
The main screen of the Support DVD looks exactly the same on the Windows® Server 2008
R2 and on the Windows® Server 2012 Operating System (OS).
7-14 Chapter 7: Driver Installation
The Drivers Menu shows the available device drivers if the system detects installed devices.
Install the necessary drivers to activate the devices.
7.3.2 Utilities menu tab
The Utilities menu displays the software applications and utilities that the motherboard supports.
7.3.1 Drivers menu tab
ASUS TS500-E8-PS4 V2 7-15
The MakeDisk menu contains items to create the Intel RAID driver disks.
7.3.3 MakeDisk menu tab
Press the arrow down button in the lower part of the menu to view more items.
7.3.4 Manual menu
The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter user guide.
You need an internet browser installed in your OS to view the User Guide.
7-16 Chapter 7: Driver Installation
7.3.5 Contact information menu
The Contact menu displays the ASUS contact information, e-mail addresses, and useful links
if you need more information or technical support for your motherboard.
ASUS TS500-E8-PS4 V2 7-17
7.4 Intel® chipset device software installation
This section provides the instructions on how to install the Intel® chipset device software on
the system.
You need to manually install the Intel® chipset device software on a Windows operating
system.
To install the Intel® chipset device software:
1. Restart the computer, and then log on with Administrator privileges.
2. Insert the motherboard/system support DVD to the optical drive. The support DVD
automatically displays the Drivers menu if Autorun is enabled in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
3. Click the item Intel Chipset Device Software from the menu.
4. The Intel® Chipset Device Software window appears. Click Next to start installation.
7-18 Chapter 7: Driver Installation
5. Select Yes to accept the terms of the License Agreement and continue the process.
6. Read the Readme File Information and press Next to continue the installation.
7. Toggle Yes, I want to restart the computer npw and click Finish to complete the
setup process.
ASUS TS500-E8-PS4 V2 7-19
5. Click Install Drivers and Software option to begin installation.
7.5 Installing the Intel® I210 Gigabit Adapters driver
This section provides the instructions on how to install the Intel® I210 Gigabits Adapter
Driver on the system.
To install the Intel® I210 Gigabit Adapters Driver on the Windows® operating system:
1. Restart the computer.
2. Log on with Administrator privileges.
3. Insert the motherboard/system support DVD to the optical drive.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
4. Click Intel® I350-AM1/I350-AM2/I210/X540-BT2 Gigabit Adapters Drivers in the
Drivers menu of the main screen to start the installation.
7-20 Chapter 7: Driver Installation
6. Click Next when the Intel(R) Network Connections–InstallShield Wizard window
appears.
7. Tick I accept the terms in the license agreement and click Next to continue.
8. From the Setup Options window, click Next to start the installation.
By default, Intel(R) PROSet for Windows Device Manager and Windows PowerShell
Module are ticked.
ASUS TS500-E8-PS4 V2 7-21
9. Click Install to start the installation.
10. When the installation is done, press Finish to complete the installation.
7-22 Chapter 7: Driver Installation
7.6 VGA driver installation
This section provides the instructions on how to install the ASPEED Video Graphics Adapter
(VGA) driver.
You need to manually install the ASPEED VGA driver on a Windows® operating system.
To install the ASPEED VGA driver:
1. Restart the computer, and then log on with Administrator privileges.
2. Insert the motherboard/system support DVD to the optical drive. The support DVD
automatically displays the Drivers menu if Autorun is enabled in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
3. Click the ASPEED AST2300 / AST2400 Display Driver to begin installation.
4. From the installation window, click Next to start the installation.
ASUS TS500-E8-PS4 V2 7-23
6. Click Finish to complete the installation.
5. Click Install to proceed with the installation.
7-24 Chapter 7: Driver Installation
This section provides the instructions on how to install the Intel® Rapid Storage Technology
enterprise 4.0 on the system.
You need to manually install the Intel® Rapid Storage Technology enterprise 4.0 utility on a
Windows® operating system.
To install the Intel® Rapid Storage Technology enterprise 4.0 utility:
1. Restart the computer, and then log on with Administrator privileges.
2. Insert the motherboard/system support DVD to the optical drive, and nd the utility
menu.
3. Click the Intel® Rapid Storage Technology enterprise 4.0 to begin installation.
4. When the Welcome to the Setup Program appears, click Next to start the installation.
7.7 Intel® Rapid Storage Technology enterprise 4.0
installation
ASUS TS500-E8-PS4 V2 7-25
5. Read the Warning message and click Next to continue.
6. Read the License Agreement and click Yes to continue.
7. Read the Readme File Information and click Next to continue.
7-26 Chapter 7: Driver Installation
9. Select
Yes, I want to restart my computer now and click Finish to restart your
computer before using the program.
8. After completing the installation, click Next to complete the setup process.
A
Appendix
Appendix
A-2 Appendix
ASUS contact information
ASUSTeK COMPUTER INC.
Address 15 Li-Te Road, Peitou, Taipei, Taiwan 11259
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
E-mail info@asus.com.tw
Web site http://www.asus.com.tw
Technical Support
Telephone +86-21-38429911
Fax +86-21-58668722 ext: 9101
Online Support http://support.asus.com/techserv/techserv.aspx
ASUSTeK COMPUTER INC. (Taiwan)
Address 15 Li-Te Road, Peitou, Taipei, Taiwan 11259
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
E-mail info@asus.com.tw
Web site http://www.asus.com.tw
Technical Support
Telephone +886-2-2894-3447 (0800-093-456)
Online Support http://support.asus.com/techserv/techserv.aspx
ASUSTeK COMPUTER INC. (China)
Address No.508, Chundong Road, Xinzhuang Industrial Zone,
Minhang District, Shanghai, China.
Telephone +86-21-5442-1616
Fax +86-21-5442-0099
Web site http://www.asus.com.cn
Technical Support
Telephone +86-21-3407-4610 (800-820-6655)
Online Support http://support.asus.com/techserv/techserv.aspx
ASUS TS500-E8-PS4 V2 A-3
ASUS contact information
ASUS COMPUTER INTERNATIONAL (America)
Address 800 Corporate Way, Fremont, CA 94539, USA
Fax +1-510-608-4555
Web site http://usa.asus.com
Technical Support
Support fax +1-812-284-0883
General support +1-812-282-2787
Online support http://support.asus.com/techserv/techserv.aspx
ASUS COMPUTER GmbH (Germany and Austria)
Address Harkort Str. 21-23, D-40880 Ratingen, Germany
Fax +49-2102-959911
Web site http://www.asus.de
Online contact http://www.asus.de/sales
Technical Support
Telephone +49-1805-010923
Support Fax +49-2102-959911
Online support http://support.asus.com/techserv/techserv.aspx
ASUS Czech Service s.r.o. (Europe)
Address Na Rovince 887, 720 00 Ostrava – Hrabová, Czech
Republic
Telephone +420-596766888
Web site http://www.asus.cz
Technical Support
Telephone +420-596-766-891
Fax +420-596-766-329
E-mail advance.rma.eu@asus.com
Online Support http://support.asus.com/techserv/techserv.aspx
A-4 Appendix
ASUS contact information
ASUS Holland BV (The Netherlands)
Address Marconistraat 2, 7825GD EMMEN, The Netherlands
Web site http://www.asus.com
Technical Support
Telephone +31-(0)591-5-70292
Fax +31-(0)591-666853
E-mail advance.rma.eu@asus.com
Online Support http://support.asus.com/techserv/techserv.aspx
ASUS Polska Sp. z o.o. (Poland)
Address Ul. Postępu 6, 02-676 Warszawa, Poland
Web site http://pl.asus.com
Technical Support
Telephone +48-225718033
Online Support http://support.asus.com/techserv/techserv.aspx
ASK-Service (Russia and CIS)
Address г.Москва, ул. Орджоникидзе, д.10, Россия
Telephone (495) 640-32-75
Web site http://ru.asus.com
Technical Support
Telephone 008-800-100-ASUS (008-800-100-2787)