Table of Contents
- Dell EMC PowerEdge R550 Installation and Service Manual
- Contents
- About this document
- System overview
- Initial system setup and configuration
- Minimum to POST and system management configuration validation
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Optional front bezel
- System cover
- Drive backplane cover
- Air shroud
- Cooling fans
- Side wall brackets
- Intrusion switch module
- Optional serial COM port
- Drives
- Drive backplane
- Cable routing
- System memory
- Processor and heat sink module
- Expansion cards
- Optional IDSDM module
- Optional BOSS S2 card
- Front mounting front PERC module
- Optional OCP card
- System battery
- Optional internal USB card
- MicroSD card
- Power supply unit
- Power interposer board
- Cooling fan cage board
- System board
- Trusted Platform Module
- Control panel
- Optional optical drive
- Jumpers and connectors
- System diagnostics and indicator codes
- Getting help
- Documentation resources
DELL R550 User Manual
Displayed below is the user manual for R550 by DELL which is a product in the Servers category. This manual has pages.
Related Manuals
Dell EMC PowerEdge R550
Installation and Service Manual
Part Number: E75S Series
Regulatory Type: E75S001
Dec. 2021
Rev. A03
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid
the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other
trademarks may be trademarks of their respective owners.
Chapter 1: About this document.................................................................................................... 7
Chapter 2: System overview..........................................................................................................8
Front view of the system...................................................................................................................................................8
Left control panel view................................................................................................................................................11
Right control panel view............................................................................................................................................. 12
Rear view of the system.................................................................................................................................................. 13
Inside the system .............................................................................................................................................................. 14
Locating the Express Service Code and Service Tag............................................................................................... 15
System information label..................................................................................................................................................15
Rail sizing and rack compatibility matrix.......................................................................................................................21
Chapter 3: Initial system setup and configuration........................................................................22
Setting up the system...................................................................................................................................................... 22
iDRAC configuration......................................................................................................................................................... 22
Options to set up iDRAC IP address....................................................................................................................... 22
Options to log in to iDRAC........................................................................................................................................ 23
Resources to install operating system......................................................................................................................... 24
Options to download firmware ................................................................................................................................24
Options to download and install OS drivers .........................................................................................................25
Downloading drivers and firmware..........................................................................................................................25
Chapter 4: Minimum to POST and system management configuration validation......................... 26
Minimum configuration to POST ..................................................................................................................................26
Configuration validation...................................................................................................................................................26
Error messages.............................................................................................................................................................27
Chapter 5: Installing and removing system components.............................................................. 28
Safety instructions............................................................................................................................................................28
Before working inside your system............................................................................................................................... 29
After working inside your system..................................................................................................................................29
Recommended tools......................................................................................................................................................... 29
Optional front bezel.......................................................................................................................................................... 30
Removing the front bezel..........................................................................................................................................30
Installing the front bezel.............................................................................................................................................31
System cover......................................................................................................................................................................32
Removing the system cover..................................................................................................................................... 32
Installing the system cover....................................................................................................................................... 33
Drive backplane cover...................................................................................................................................................... 34
Removing the drive backplane cover......................................................................................................................34
Installing the drive backplane cover........................................................................................................................35
Air shroud............................................................................................................................................................................ 37
Removing the air shroud............................................................................................................................................ 37
Installing the air shroud.............................................................................................................................................. 37
Contents
Contents 3
Cooling fans........................................................................................................................................................................ 38
Removing the cooling fan cage assembly..............................................................................................................38
Installing the cooling fan cage assembly................................................................................................................39
Removing a cooling fan..............................................................................................................................................40
Installing a cooling fan.................................................................................................................................................41
Side wall brackets............................................................................................................................................................. 42
Removing the side wall bracket............................................................................................................................... 42
Installing the side wall bracket................................................................................................................................. 43
Intrusion switch module................................................................................................................................................... 44
Removing the intrusion switch module.................................................................................................................. 44
Installing the intrusion switch module.................................................................................................................... 45
Optional serial COM port.................................................................................................................................................46
Removing the optional serial COM port.................................................................................................................46
Installing the optional serial COM port ..................................................................................................................47
Drives................................................................................................................................................................................... 48
Removing a drive blank.............................................................................................................................................. 48
Installing a drive blank................................................................................................................................................ 49
Removing the drive carrier........................................................................................................................................49
Installing the drive carrier..........................................................................................................................................50
Removing the drive from the drive carrier.............................................................................................................51
Installing the drive into the drive carrier................................................................................................................52
Drive backplane................................................................................................................................................................. 53
Drive backplane............................................................................................................................................................53
Removing the drive backplane ................................................................................................................................ 54
Installing the drive backplane................................................................................................................................... 55
Cable routing...................................................................................................................................................................... 57
System memory.................................................................................................................................................................60
System memory guidelines........................................................................................................................................60
General memory module installation guidelines.................................................................................................... 61
Removing a memory module.....................................................................................................................................62
Installing a memory module.......................................................................................................................................63
Processor and heat sink module....................................................................................................................................64
Removing processor and heat sink module...........................................................................................................64
Removing the processor from the processor and heat sink module.............................................................. 66
Installing the processor into a processor and heat sink module...................................................................... 68
Installing the processor heat sink module..............................................................................................................72
Expansion cards................................................................................................................................................................. 74
Expansion card installation guidelines.....................................................................................................................75
Removing the expansion card.................................................................................................................................. 78
Installing the expansion card.....................................................................................................................................79
Optional IDSDM module................................................................................................................................................... 81
Removing the IDSDM module................................................................................................................................... 81
Installing the IDSDM module..................................................................................................................................... 81
Optional BOSS S2 card....................................................................................................................................................82
Removing the BOSS S2 module.............................................................................................................................. 82
Installing the BOSS S2 module.................................................................................................................................85
Front mounting front PERC module............................................................................................................................. 88
Removing the front mounting front PERC module............................................................................................. 88
Installing the front mounting front PERC module............................................................................................... 89
Optional OCP card............................................................................................................................................................ 90
4Contents
Removing the OCP shroud....................................................................................................................................... 90
Installing the OCP shroud.......................................................................................................................................... 91
Removing the OCP card............................................................................................................................................ 92
Installing the OCP card.............................................................................................................................................. 93
System battery ................................................................................................................................................................. 94
Replacing the system battery...................................................................................................................................94
Optional internal USB card............................................................................................................................................. 96
Removing the internal USB card............................................................................................................................. 96
Installing the internal USB card................................................................................................................................97
MicroSD card......................................................................................................................................................................97
Removing the MicroSD card.....................................................................................................................................97
Installing the MicroSD card.......................................................................................................................................98
Power supply unit..............................................................................................................................................................99
Hot spare feature........................................................................................................................................................ 99
Removing a power supply unit blank.....................................................................................................................100
Installing a power supply unit blank.......................................................................................................................100
Removing a power supply unit................................................................................................................................ 101
Installing a power supply unit...................................................................................................................................101
Power interposer board................................................................................................................................................. 102
Removing the power interposer board................................................................................................................. 102
Installing the power interposer board................................................................................................................... 103
Cooling fan cage board.................................................................................................................................................. 104
Removing the cooling fan cage board.................................................................................................................. 104
Installing the cooling fan cage board.................................................................................................................... 105
System board....................................................................................................................................................................106
Removing the system board................................................................................................................................... 106
Installing the system board......................................................................................................................................107
Restoring the system using Easy Restore........................................................................................................... 109
Trusted Platform Module...............................................................................................................................................109
Upgrading the Trusted Platform Module............................................................................................................. 109
Initializing TPM for users.......................................................................................................................................... 110
Initializing the TPM 1.2 for users............................................................................................................................ 110
Initializing the TPM 2.0 for users............................................................................................................................110
Control panel...................................................................................................................................................................... 111
Removing the left control panel.............................................................................................................................. 111
Installing the left control panel................................................................................................................................112
Removing the right control panel........................................................................................................................... 112
Installing the right control panel............................................................................................................................. 113
Optional optical drive.......................................................................................................................................................115
Removing the optical disk drive.............................................................................................................................. 115
Installing the optical disk drive ............................................................................................................................... 115
Chapter 6: Jumpers and connectors........................................................................................... 117
System board connectors...............................................................................................................................................117
System board jumper settings.......................................................................................................................................118
Disabling a forgotten password.................................................................................................................................... 119
Chapter 7: System diagnostics and indicator codes....................................................................120
Status LED indicators..................................................................................................................................................... 120
Contents 5
System health and system ID indicator codes...........................................................................................................121
iDRAC Quick Sync 2 indicator codes.......................................................................................................................... 122
iDRAC Direct LED indicator codes.............................................................................................................................. 122
LCD panel.......................................................................................................................................................................... 123
Viewing Home screen............................................................................................................................................... 124
Setup menu................................................................................................................................................................. 124
View menu................................................................................................................................................................... 124
NIC indicator codes.........................................................................................................................................................125
Power supply unit indicator codes...............................................................................................................................125
Drive indicator codes...................................................................................................................................................... 127
Using system diagnostics...............................................................................................................................................128
Dell Embedded System Diagnostics...................................................................................................................... 128
Chapter 8: Getting help............................................................................................................. 130
Recycling or End-of-Life service information........................................................................................................... 130
Contacting Dell Technologies....................................................................................................................................... 130
Accessing system information by using QRL............................................................................................................130
Quick Resource Locator for PowerEdge R550 system.....................................................................................131
Receiving automated support with SupportAssist ..................................................................................................131
Chapter 9: Documentation resources......................................................................................... 132
6Contents
About this document
This document provides an overview about the system, information about installing and replacing components, diagnostic tools,
and guidelines to be followed while installing certain components.
1
About this document 7
System overview
The PowerEdge R550 system is a dual socket, 2U rack system that supports:
●Up to two 3rd Generation Intel Xeon Scalable processors with up to 24 cores per processor.
●16 DDR4 DIMM slots
●Two redundant AC or DC power supply units
●8 x 2.5-inch SAS/ SATA drives
●16 x 2.5-inch SAS/ SATA drives
●8 x 3.5-inch SAS/ SATA drives
NOTE: All instances of SAS, SATA drives are referred to as drives in this document, unless specified otherwise.
NOTE: For more information, see the Dell EMC PowerEdge R550 Technical Specifications on the product documentation
page.
Topics:
•Front view of the system
•Rear view of the system
•Inside the system
•Locating the Express Service Code and Service Tag
•System information label
•Rail sizing and rack compatibility matrix
Front view of the system
Figure 1. Front view of the 16 x 2.5-inch drive system
Table 1. Features available on the front of the system
Item Ports, panels, and
slots
Icon Description
1 Left control panel N/A Contains the system health, system ID, status LED and the
iDRAC Quick Sync 2 (wireless) indicator.
NOTE: The iDRAC Quick Sync 2 indicator is available only
on certain configurations.
●Status LED: Enables you to identify any failed hardware
components. There are up to five status LEDs and an overall
system health LED (Chassis health and system ID) bar. For
more information, see the Status LED indicators section.
2
8 System overview
Table 1. Features available on the front of the system (continued)
Item Ports, panels, and
slots
Icon Description
●Quick Sync 2 (wireless): Indicates a Quick Sync enabled
system. The Quick Sync feature is optional. This feature
allows management of the system by using mobile devices
called as OpenManage Mobile (OMM) feature. Using iDRAC
Quick Sync 2 with OpenManage Mobile (OMM) aggregates
hardware or firmware inventory and various system level
diagnostic and error information that can be used in
troubleshooting the system. For more information, see the
Integrated Dell Remote Access Controller User's Guide
available at https://www.dell.com/idracmanuals
2 Drive N/A Enables you to install drives that are supported on your system.
3 Right control panel and
VGA port
Contains the power button, USB port, iDRAC Direct micro port,
and the iDRAC Direct status LED. VGA port enables you to
connect a display device to the system.
4 Information tag N/A The Information tag is a slide-out label panel that contains
system information such as Service Tag, NIC, MAC address,
and so on. If you have opted for the secure default access
to iDRAC, the Information tag also contains the iDRAC secure
default password.
Figure 2. Front view of the 8 x 2.5-inch drive system
Table 2. Features available on the front of the system
Item Ports, panels, and
slots
Icon Description
1 Left control panel N/A Contains the system health, system ID, status LED and the
iDRAC Quick Sync 2 (wireless) indicator.
NOTE: The iDRAC Quick Sync 2 indicator is available only
on certain configurations.
●Status LED: Enables you to identify any failed hardware
components. There are up to five status LEDs and an overall
system health LED (Chassis health and system ID) bar. For
more information, see the Status LED indicators section.
●Quick Sync 2 (wireless): Indicates a Quick Sync enabled
system. The Quick Sync feature is optional. This feature
allows management of the system by using mobile devices
called as OpenManage Mobile (OMM) feature. Using iDRAC
Quick Sync 2 with OpenManage Mobile (OMM) aggregates
hardware or firmware inventory and various system level
diagnostic and error information that can be used in
troubleshooting the system. For more information, see the
Integrated Dell Remote Access Controller User's Guide
available at https://www.dell.com/idracmanuals
System overview 9
Table 2. Features available on the front of the system (continued)
Item Ports, panels, and
slots
Icon Description
2 Drive N/A Enables you to install drives that are supported on your system.
3 Right control panel and
VGA port
Contains the power button, USB port, iDRAC Direct micro port,
and the iDRAC Direct status LED. VGA port enables you to
connect a display device to the system.
4 Information tag N/A The Information tag is a slide-out label panel that contains
system information such as Service Tag, NIC, MAC address,
and so on. If you have opted for the secure default access
to iDRAC, the Information tag also contains the iDRAC secure
default password.
Figure 3. Front view of the 8 x 3.5-inch drive system
Table 3. Features available on the front of the system
Item Ports, panels, and
slots
Icon Description
1 Left control panel N/A Contains the system health, system ID, status LED and the
iDRAC Quick Sync 2 (wireless) indicator.
NOTE: The iDRAC Quick Sync 2 indicator is available only
on certain configurations.
●Status LED: Enables you to identify any failed hardware
components. There are up to five status LEDs and an overall
system health LED (Chassis health and system ID) bar. For
more information, see the Status LED indicators section.
●Quick Sync 2 (wireless): Indicates a Quick Sync enabled
system. The Quick Sync feature is optional. This feature
allows management of the system by using mobile devices
called as OpenManage Mobile (OMM) feature. Using iDRAC
Quick Sync 2 with OpenManage Mobile (OMM) aggregates
hardware or firmware inventory and various system level
diagnostic and error information that can be used in
troubleshooting the system. For more information, see the
Integrated Dell Remote Access Controller User's Guide
available at https://www.dell.com/idracmanuals
2 Optical drive blank N/A For the 8 x 3.5-inch drive system, a optical drive bay blank is
installed.
3 Drive N/A Enables you to install drives that are supported on your system.
4 Right control panel and
VGA port
Contains the power button, USB port, iDRAC Direct micro port,
and the iDRAC Direct status LED. VGA port enables you to
connect a display device to the system.
5 Information tag N/A The Information tag is a slide-out label panel that contains
system information such as Service Tag, NIC, MAC address,
10 System overview
Table 3. Features available on the front of the system (continued)
Item Ports, panels, and
slots
Icon Description
and so on. If you have opted for the secure default access
to iDRAC, the Information tag also contains the iDRAC secure
default password.
NOTE: For more information, see the Dell EMC PowerEdge R550 Technical Specifications on the product documentation
page.
Left control panel view
Figure 4. Left control panel without optional iDRAC Quick Sync 2 indicator
Table 4. Left control panel without optional iDRAC Quick Sync 2 indicator
Item Indicator, button, or
connector
Icon Description
1 Status LED indicators N/A Indicates the status of the system. For more information, see the
Status LED indicators section.
2 System health and system
ID indicator
Indicates the system health. For more information, see the
System health and system ID indicator codes section.
Figure 5. Left control panel with optional iDRAC Quick Sync 2 indicator
Table 5. Left control panel with optional iDRAC Quick Sync 2 indicator
Item Indicator, button, or
connector
Icon Description
1 Status LED indicators N/A Indicates the status of the system. For more information, see the
Status LED indicators section.
2 System health and system
ID indicator
Indicates the system health. For more information, see the
System health and system ID indicator codes section.
System overview 11
Table 5. Left control panel with optional iDRAC Quick Sync 2 indicator (continued)
Item Indicator, button, or
connector
Icon Description
3 iDRAC Quick Sync
2 wireless indicator
(optional)
Indicates if the iDRAC Quick Sync 2 wireless option is
activated. The Quick Sync 2 feature allows management of the
system using mobile devices. This feature aggregates hardware/
firmware inventory and various system level diagnostic/error
information that can be used in troubleshooting the system. You
can access system inventory, Dell Lifecycle Controller logs or
system logs, system health status, and also configure iDRAC,
BIOS, and networking parameters. You can also launch the virtual
Keyboard, Video, and Mouse (KVM) viewer and virtual Kernel-
based Virtual Machine (KVM), on a supported mobile device.
For more information, see the Integrated Dell Remote Access
Controller User's Guide at www.dell.com/poweredgemanuals.
NOTE: For more information about the indicator codes, see the System diagnostics and indicator codes section.
Right control panel view
Figure 6. Right control panel view
Table 6. Right control panel
Ite
m
Indicator or button Icon Description
1 Power button Indicates if the system is powered on or off. Press the power button to
manually power on or off the system.
NOTE: Press the power button to gracefully shut down the ACPI-
compliant operating system.
2 USB 2.0-compliant port The USB port is a 4-pin connector and 2.0-compliant. This port enables
you to connect USB devices to the system.
3 iDRAC Direct port
(Micro-AB USB)
The iDRAC Direct port (Micro-AB USB) enables you to access
the iDRAC Direct Micro-AB features. For more information, see the
Integrated Dell Remote Access Controller User's Guide available at
https://www.dell.com/idracmanuals .
NOTE: You can configure iDRAC Direct by using a USB to micro USB
(type AB) cable, which you can connect to your laptop or tablet. Cable
length should not exceed 3 feet (0.91 meters). Performance could be
affected by cable quality.
4 VGA port Enables you to connect a display device to the system.
12 System overview
NOTE: For more information, see the Dell EMC PowerEdge R550 Technical Specifications on the product documentation
page.
Rear view of the system
Figure 7. Rear view of the system
Table 7. Rear view of the system
Item Ports, panels, or slots Icon Description
1 PCIe expansion card slot 1 N/A Enables you to connect PCI Express expansion cards.
2 PCIe expansion card slot
2
N/A Enables you to connect PCI Express expansion cards.
3 PCIe expansion card slot
5
N/A Enables you to connect PCI Express expansion cards.
4 System identification
button
Press the system ID button:
●To locate a particular system within a rack.
●To turn the system ID on or off.
To reset iDRAC, press and hold the button for more than 16
seconds.
NOTE:
●To reset iDRAC using system ID, ensure that the system ID
button is enabled in the iDRAC setup.
●If the system stops responding during POST, press and hold
the system ID button (for more than 5 seconds) to enter
the BIOS progress mode.
5 PCIe expansion card slot
6
N/A Enables you to connect PCI Express expansion cards.
6BOSS S2 module N/A Enables you to connect BOSS S2 module.
7Power supply unit (PSU
2)
Indicates the PSU 2.
8Power supply unit (PSU 1) Indicates the PSU 1.
9VGA port Enables you to connect a display device to the system.
10 OCP NIC port (optional) N/A This port supports OCP 3.0. The NIC ports are integrated on the
OCP card which is connected to the system board.
11 USB 3.0 port This port is USB 3.0-compliant.
12 USB 2.0 port This port is USB 2.0-compliant.
System overview 13
Table 7. Rear view of the system (continued)
Item Ports, panels, or slots Icon Description
13 iDRAC dedicated port Enables you to remotely access iDRAC. For more information, see
the iDRAC User's Guide at www.dell.com/poweredgemanuals
14 NIC ports (1, 2) The NIC ports are embedded on the LOM card that is connected to
the system board to provide network connectivity. These NIC ports
can also be shared with iDRAC when iDRAC network settings is set
to shared mode.
NOTE: For more information, see the Dell EMC PowerEdge R550 Technical Specifications on the product documentation
page.
Inside the system
Figure 8. Inside the system
1. Front PERC 2. Optical disk drive (ODD)
3. Cooling fan 4. Power interposer board
5. Intrusion switch 6. BOSS module tray
7. OCP 8. PSU 1 and PSU 2
9. System board 10. Processor and heat sink module
11. Memory module slots 12. Backplane
13. Information tag
14 System overview
Locating the Express Service Code and Service Tag
The unique Express Service Code and Service Tag are used to identify the system.
The information tag is located on the front of the system that includes system information such as the Service Tag, Express
Service Code, Manufacture date, NIC, MAC address, QRL label, and so on. If you have opted for the secure default access
to iDRAC, the Information tag also contains the iDRAC secure default password. If you have opted for iDRAC Quick Sync
2, the Information tag also contains the OpenManage Mobile (OMM) label, where administrators can configure, monitor, and
troubleshoot the PowerEdge servers.
Figure 9. Locating the Express Service Code and Service tag
1. Information tag (front view)
2. Information tag (back view)
3. OpenManage Mobile (OMM) label
4. iDRAC MAC address and iDRAC secure password label
5. Service Tag, Express Service Code, QRL label
The Mini Enterprise Service Tag (MEST) label is located on the rear of the system that includes the Service Tag (ST), Express
Service Code (Exp Svc Code), and Manufacture Date (Mfg. Date). The Exp Svc Code is used by Dell EMC to route support calls
to the appropriate personnel.
Alternatively, the Service Tag information is located on a label on the left wall of the chassis.
System information label
The system information label is located on back of the system cover.
System overview 15
Figure 10. Service information
16 System overview
Figure 11. Service information
System overview 17
Figure 12. Memory information
Figure 13. Configuration and layout
18 System overview
Figure 14. Configuration and layout
Figure 15. LED behavior
System overview 19
Figure 16. System tasks
20 System overview
Figure 17. Express service tag
Rail sizing and rack compatibility matrix
For specific information about the rail solutions compatible with your system, see the Dell EMC Enterprise Systems
Rail Sizing and Rack Compatibility Matrix available at https://i.dell.com/sites/csdocuments/Business_solutions_engineering-
Docs_Documents/en/rail-rack-matrix.pdf.
The document provides the information that is listed below:
●Specific details about rail types and their functionalities.
●Rail adjustability range for various types of rack mounting flanges.
●Rail depth with and without cable management accessories.
●Types of racks supported for various types of rack mounting flanges.
System overview 21
Initial system setup and configuration
This section describes the tasks for initial setup and configuration of the Dell EMC system. The section also provides general
steps to set up the system and the reference guides for detailed information.
Topics:
•Setting up the system
•iDRAC configuration
•Resources to install operating system
Setting up the system
Perform the following steps to set up the system:
Steps
1. Unpack the system.
2. Install the system into the rack. For more information, see the rail installation and cable management accessory guides
relevant to your rail and cable management solution at www.dell.com/poweredgemanuals.
3. Connect the peripherals to the system and the system to the electrical outlet.
4. Power on the system.
For more information about setting up the system, see the Getting Started Guide that is shipped with your system.
NOTE: For information about managing the basic settings and features of the system, see the Dell EMC PowerEdge
R550 BIOS and UEFI Reference Guide on the product documentation page.
iDRAC configuration
The Integrated Dell Remote Access Controller (iDRAC) is designed to make you more productive as a system administrator
and improve the overall availability of Dell EMC servers. iDRAC alerts you to system issues, helps you to perform remote
management, and reduces the need for physical access to the system.
Options to set up iDRAC IP address
To enable communication between your system and iDRAC, you must first configure the network settings based on your
network infrastructure. The network settings option is set to DHCP, by default.
NOTE: For static IP configuration, you must request for the settings at the time of purchase.
You can set up the iDRAC IP address using one of the interfaces in the table below. For information about setting up iDRAC IP
address, see the documentation links provided in the table below.
Table 8. Interfaces to set up iDRAC IP address
Interface Documentation links
iDRAC Settings utility Integrated Dell Remote Access Controller User's Guide at
https://www.dell.com/idracmanuals or for system specific
Integrated Dell Remote Access Controller User's Guide,
go to https://www.dell.com/poweredgemanuals > Product
Support page of your system > Documentation.
3
22 Initial system setup and configuration
Table 8. Interfaces to set up iDRAC IP address (continued)
Interface Documentation links
NOTE: To determine the most recent iDRAC release
for your platform and for latest documentation version,
see KB article https://www.dell.com/support/article/
sln308699.
OpenManage Deployment Toolkit Dell EMC OpenManage Deployment Toolkit User's Guide
available at https://www.dell.com/openmanagemanuals >
Open Manage Deployment Toolkit.
iDRAC Direct Integrated Dell Remote Access Controller User's Guide at
https://www.dell.com/idracmanuals or for system specific
Integrated Dell Remote Access Controller User's Guide,
go to https://www.dell.com/poweredgemanuals > Product
Support page of your system > Documentation.
NOTE: To determine the most recent iDRAC release
for your platform and for latest documentation version,
see KB article https://www.dell.com/support/article/
sln308699.
Lifecycle Controller Dell Lifecycle Controller User's Guide at https://
www.dell.com/idracmanuals or for system specific Dell
Lifecycle Controller User's Guide, go to https://
www.dell.com/poweredgemanuals > Product Support page
of your system > Documentation.
NOTE: To determine the most recent iDRAC release
for your platform and for latest documentation version,
see KB article https://www.dell.com/support/article/
sln308699.
Server LCD panel LCD panel section.
iDRAC Direct and Quick Sync 2 (optional) Integrated Dell Remote Access Controller User's Guide at
https://www.dell.com/idracmanuals or for system specific
Integrated Dell Remote Access Controller User's Guide,
go to https://www.dell.com/poweredgemanuals > Product
Support page of your system > Documentation.
NOTE: To determine the most recent iDRAC release
for your platform and for latest documentation version,
see KB article https://www.dell.com/support/article/
sln308699.
NOTE: To access iDRAC, ensure that you connect the ethernet cable to the iDRAC dedicated network port or use the
iDRAC Direct port by using the USB cable. You can also access iDRAC through the shared LOM mode, if you have opted for
a system that has the shared LOM mode enabled.
Options to log in to iDRAC
To log in to the iDRAC Web User Interface, open a browser and enter the IP address.
You can log in to iDRAC as:
●iDRAC user
●Microsoft Active Directory user
●Lightweight Directory Access Protocol (LDAP) user
In the login screen displayed, if you have opted for secure default access to iDRAC, enter the iDRAC secure default password
available on back of the Information Tag. If you have not opted for secure default access to iDRAC, enter the default user name
and password – root and calvin. You can also log in by using your Single Sign-On or Smart Card.
Initial system setup and configuration 23
NOTE: Ensure that you change the default username and password after setting up the iDRAC IP address.
For more information about logging in to the iDRAC and iDRAC licenses, see the latest Integrated Dell Remote Access Controller
User's Guide at www.dell.com/idracmanuals.
NOTE: To determine the most recent iDRAC release for your platform and for latest documentation version, see KB article
https://www.dell.com/support/article/sln308699.
You can also access iDRAC using command-line protocol - RACADM. For more information, see the Integrated Dell Remote
Access Controller RACADM CLI Guide available at https://www.dell.com/idracmanuals.
You can also access iDRAC using automation tool - Redfish API. For more information, see the Integrated Dell Remote Access
Controller User's Guide Redfish API Guide available at https://developer.dell.com.
Resources to install operating system
If the system is shipped without an operating system, you can install a supported operating system by using one of the
resources provided in the table below. For information about how to install the operating system, see the documentation links
provided in the table below.
Table 9. Resources to install the operating system
Resource Documentation links
iDRAC Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals or for
system specific Integrated Dell Remote Access Controller User's Guide, go to https://www.dell.com/
poweredgemanuals > Product Support page of your system > Documentation.
NOTE: To determine the most recent iDRAC release for your platform and for latest
documentation version, see KB article at https://www.dell.com/support/article/sln308699.
Lifecycle Controller Dell Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals or for system specific
Dell Lifecycle Controller User's Guide, go to https://www.dell.com/poweredgemanuals > Product
Support page of your system > Documentation. Dell recommends using Lifecycle Controller to install
the OS, since all required drivers are installed on the system.
NOTE: To determine the most recent iDRAC release for your platform and for latest
documentation version, see KB article at https://www.dell.com/support/article/sln308699.
OpenManage
Deployment Toolkit
www.dell.com/openmanagemanuals > OpenManage Deployment Toolkit
Dell certified VMware
ESXi
www.dell.com/virtualizationsolutions
NOTE: For more information about installation and how-to videos for operating systems supported on PowerEdge systems,
see Supported Operating Systems for Dell EMC PowerEdge systems.
Options to download firmware
You can download firmware from the Dell support site. For information about downloading firmware, see the Downloading
drivers and firmware section.
You can also choose any one of the following options to download the firmware. For information about how to download the
firmware, see the documentation links provided in the table below.
Table 10. Options to download firmware
Option Documentation link
Using Integrated Dell Remote Access Controller Lifecycle
Controller (iDRAC with LC)
www.dell.com/idracmanuals
Using Dell Repository Manager (DRM) www.dell.com/openmanagemanuals > Repository Manager
Using Dell Server Update Utility (SUU) www.dell.com/openmanagemanuals > Server Update Utility
24 Initial system setup and configuration
Table 10. Options to download firmware (continued)
Option Documentation link
Using Dell OpenManage Deployment Toolkit (DTK) www.dell.com/openmanagemanuals > OpenManage
Deployment Toolkit
Using iDRAC virtual media www.dell.com/idracmanuals
Options to download and install OS drivers
You can choose any one of the following options to download and install OS drivers. For information about how to download or
install OS drivers, see the documentation links provided in the table below.
Table 11. Options to download and install OS drivers
Option Documentation
Dell EMC support site Downloading drivers and firmware section.
iDRAC virtual media Integrated Dell Remote Access Controller User's Guide at
https://www.dell.com/idracmanuals or for system specific
Integrated Dell Remote Access Controller User's Guide,
go to https://www.dell.com/poweredgemanuals > Product
Support page of your system > Documentation .
NOTE: To determine the most recent iDRAC release for
your platform and for latest documentation version, see
https://www.dell.com/support/article/sln308699.
Downloading drivers and firmware
It is recommended that you download and install the latest BIOS, drivers, and systems management firmware on the system.
Prerequisites
Ensure that you clear the web browser cache before downloading the drivers and firmware.
Steps
1. Go to www.dell.com/support/drivers.
2. Enter the Service Tag of the system in the Enter a Dell Service Tag, Dell EMC Product ID or Model field, and then press
Enter.
NOTE: If you do not have the Service Tag, click Browse all products, and navigate to your product.
3. On the displayed product page, click Drivers & Downloads.
On the Drivers & Downloads page, all drivers that are applicable to the system are displayed.
4. Download the drivers to a USB drive, CD, or DVD.
Initial system setup and configuration 25
Minimum to POST and system management
configuration validation
This section describes the minimum to POST system requirement and system management configuration validation of the Dell
EMC system.
Topics:
•Minimum configuration to POST
•Configuration validation
Minimum configuration to POST
The components listed below are the minimum configuration to POST:
●One power supply unit
●System board
●One processor in socket processor 1
●One memory module (DIMM) installed in the socket A1
Configuration validation
The new generation of PowerEdge systems have added interconnect flexibility and advanced iDRAC management features to
collect precise system configuration information and report configuration errors.
When the system is powered on, information about installed cables, backplanes, floating card (fPERClike BOSS), and processor
is obtained from the CPLD and backplane memory maps is analyzed. This information forms a unique configuration, which is
compared with one of the qualified configurations stored in a table maintained by iDRAC.
One or more sensors are assigned to each of the configuration elements. During POST, any configuration validation error is
logged in the System Event Log (SEL)/LifeCycle (LC) log. The reported events are categorized in the configuration validation
error table.
Table 12. Configuration validation error
Error Description Possible cause and
recommendations
Example
Config Error A configuration element within the
closest match contains something that is
unexpected and does not match any Dell
qualified configuration.
Wrong configuration Config Error: Backplane cable
CTRS_SRC_SA1 and BP-DST_SA1
The element reported
in HWC8010 errors are
assembled incorrectly.
Verify element (cable, etc)
placement in the system.
Config Error : SL Cable
PLANAR_SL7 and CTRL_DST_PA1
Config
Missing
iDRAC found a configuration element
missing within the closest match
detected.
Missing or damaged cable,
device, or part
Config Missing: Float card front
PERC/HBA
Missing element or cable
is reported in HWC8010
error logs. Install the
missing element (cable,
etc).
Config Missing : SL cable
PLANAR_SL8 and CTRL_DST_PA1
4
26 Minimum to POST and system management configuration validation
Table 12. Configuration validation error (continued)
Error Description Possible cause and
recommendations
Example
Comm Error A configuration element is not responding
to iDRAC using the management interface
while running an inventory check.
System management
sideband communication
Comm Error: Backplane 2
Unplug AC Power, reseat
the element and replace
the element if the problem
persists.
Error messages
This section describes the error messages displayed on the screen during POST or captured in the system event log (SEL)/
LifeCycle (LC) log.
Table 13. Error message HWC8010
Error code HWC8010
Message The System Configuration Check operation resulted in the following issue involving the indicated
component type
Arguments Riser, floating card (fPERClike BOSS), backplane, processor, cable, or other components
Detailed Description The issue identified in the message is observed in the System Configuration Check operation.
Recommended
Response Action
Do the following and retry the operation:
1. Disconnect the input power.
2. Check for proper cable connection and component placement. If the issue persists, contact the
service provider.
Category System Health (HWC = Hardware Config)
Severity Critical
Trap/EventID 2329
Table 14. Error message HWC8011
Error code HWC8011
Message The System Configuration Check operation resulted in multiple issues involving the indicated component
type
Arguments Riser, floating card (fPERClike BOSS), backplane, processor, cable, or other components
Detailed Description Multiple issues are observed in the System Configuration Check operation.
Recommended
Response Action
Do the following and retry the operation:
1. Disconnect the input power.
2. Check for proper cable connection and component placement. If the issue persists, contact the
service provider.
Category System Health (HWC = Hardware Config)
Severity Critical
Minimum to POST and system management configuration validation 27
Installing and removing system components
Topics:
•Safety instructions
•Before working inside your system
•After working inside your system
•Recommended tools
•Optional front bezel
•System cover
•Drive backplane cover
•Air shroud
•Cooling fans
•Side wall brackets
•Intrusion switch module
•Optional serial COM port
•Drives
•Drive backplane
•Cable routing
•System memory
•Processor and heat sink module
•Expansion cards
•Optional IDSDM module
•Optional BOSS S2 card
•Front mounting front PERC module
•Optional OCP card
•System battery
•Optional internal USB card
•MicroSD card
•Power supply unit
•Power interposer board
•Cooling fan cage board
•System board
•Trusted Platform Module
•Control panel
•Optional optical drive
Safety instructions
NOTE: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system by
yourself.
CAUTION: Ensure that two or more people lift the system horizontally from the box and place it on a flat
surface, rack lift, or into the rails.
WARNING: Opening or removing the system cover while the system is powered on may expose you to a risk of
electric shock.
WARNING: Do not operate the system without the cover for a duration exceeding five minutes. Operating the
system without the system cover can result in component damage.
5
28 Installing and removing system components
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
NOTE: It is recommended that you always use an antistatic mat and antistatic strap while working on components inside
the system.
CAUTION: To ensure proper operation and cooling, all system bays and fans must always be populated with a
component or a blank.
NOTE: While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For updating to the latest firmware and changing the configuration, see the
Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals.
NOTE: While replacing faulty storage controller, FC, or NIC card with the same type of card, after you power on the
system; the new card automatically updates to the same firmware and configuration of the faulty one. For updating to
the latest firmware and changing the configuration, see the Lifecycle Controller User's Guide at https://www.dell.com/
idracmanuals.
CAUTION: Do not install GPUs, network cards, or other PCIe devices on your system that are not validated
and tested by Dell. Damage caused by unauthorized and invalidated hardware installation will null and void the
system warranty.
Before working inside your system
Prerequisites
Follow the safety guidelines listed in the Safety instructions.
Steps
1. Power off the system and all attached peripherals.
2. Disconnect the system from the electrical outlet, and disconnect the peripherals.
3. If applicable, remove the system from the rack.
For more information, see the Rail Installation Guide relevant to your rail solutions at www.dell.com/poweredgemanuals.
4. Remove the system cover.
After working inside your system
Prerequisites
Follow the safety guidelines listed in Safety instructions.
Steps
1. Replace the system cover.
2. If applicable, install the system into the rack.
For more information, see the Rail Installation Guide relevant to your system at www.dell.com/poweredgemanuals.
3. Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.
Recommended tools
You may need any or combination of the following tools to perform the removal and installation procedures:
●Key to the bezel lock. The key is required only if your system includes a bezel.
●Phillips 1 screwdriver
Installing and removing system components 29
●Phillips 2 screwdriver
●Torx T30 screwdriver
●5 mm hex nut screwdriver
●Plastic scribe
●1/4-inch flat blade screwdriver
●Wrist grounding strap connected to the ground
●ESD mat
●Needle-nose pliers
You need the following tools to assemble the cables for a DC power supply unit:
●AMP 90871-1 hand-crimping tool or equivalent
●Tyco Electronics 58433-3 or equivalent
●Wire-stripper pliers to remove insulation from size 10 AWG solid or stranded, insulated copper wire
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding).
Optional front bezel
NOTE: LCD panel is optional on the front bezel. If the front bezel has an LCD panel, see LCD panel section.
Removing the front bezel
The procedure to remove the front bezel with and without the LCD panel is the same.
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Keep the bezel key handy.
NOTE: The bezel key is part of the LCD bezel package.
Steps
1. Unlock the front bezel.
2. Press the release button, and disengage the left end of the bezel.
3. Unhook the right end, and remove the bezel.
30 Installing and removing system components
Figure 18. Removing the front bezel with the LCD panel
Next steps
Replace the front bezel.
Installing the front bezel
The procedure to install the front bezel with and without the LCD panel is the same.
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Locate and remove the bezel key.
NOTE: The bezel key is part of the LCD bezel package.
Steps
1. Align and insert the tabs on the bezel into the slots on the system.
2. Press the bezel until the release button clicks in place.
3. Lock the front bezel.
Figure 19. Installing the front bezel with the LCD panel
Installing and removing system components 31
System cover
Removing the system cover
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Power off the system, and any attached peripherals.
3. Disconnect the system from the electrical outlet and peripherals.
Steps
1. Using a 1/4-inch flat head or Phillips #2 screwdriver, rotate the lock counterclockwise to the unlock position.
2. Lift the release latch until the system cover slides back.
3. Lift the cover from the system.
32 Installing and removing system components
Figure 20. Removing the system cover
Next steps
Replace the system cover.
Installing the system cover
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Ensure that all internal cables are connected and routed properly, and no tools or extra parts are left inside the system.
Steps
1. Align the tabs on the system cover with the guide slots on the system.
2. Close the system cover release latch.
3. Using a 1/4-inch flat head or Phillips #2 screwdriver, rotate the lock clockwise to the lock position.
Installing and removing system components 33
Figure 21. Installing the system cover
Next steps
Follow the procedure listed in After working inside your system.
Drive backplane cover
Removing the drive backplane cover
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Slide the drive backplane cover in the direction of the arrows marked on the drive backplane cover.
2. Lift the drive backplane cover from the system.
34 Installing and removing system components
Figure 22. Removing the drive backplane cover
Next steps
Replace the drive backplane cover.
Installing the drive backplane cover
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Align the drive backplane cover with the guide slots on the system.
2. Slide the drive backplane cover toward the front of the system until the drive backplane cover fits into place.
Installing and removing system components 35
Air shroud
Removing the air shroud
Prerequisites
CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly,
resulting in shutdown of the system and loss of data.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
Hold the air shroud at both ends and lift the air shroud out of the system.
Figure 24. Removing the air shroud
Next steps
Replace the air shroud.
Installing the air shroud
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Align the slot on the air shroud with the standoff on the system.
2. Lower the air shroud into the system until it is firmly seated.
Installing and removing system components 37
Figure 25. Installing the air shroud
Next steps
Follow the procedure listed in After working inside your system.
Cooling fans
Removing the cooling fan cage assembly
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If installed, remove the air shroud.
Steps
1. Lift the blue release levers to unlock the cooling fan cage from the system.
2. Hold the release levers, and lift the cooling fan cage away from the system.
38 Installing and removing system components
Figure 26. Removing the cooling fan cage assembly
Next steps
1. Replace the cooling fan cage.
Installing the cooling fan cage assembly
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
CAUTION: Ensure that the cables inside the system are correctly installed and retained by the cable
retention bracket before installing the cooling fan cage assembly. Incorrectly installed cables may get
damaged.
2. Follow the procedure listed in Before working inside your system.
3. If installed, remove the air shroud.
Steps
1. Align the guide rails on the cooling fan cage with the standoffs on the system.
2. Lower the cooling fan cage into the system.
3. Lower the blue release levers to lock the cooling fan cage into the system.
Installing and removing system components 39
Figure 27. Installing the cooling fan cage assembly
Next steps
1. If removed, Install the air shroud.
2. Follow the procedure listed in After working inside your system.
Removing a cooling fan
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
Press the blue release tab and lift the cooling fan to disconnect the fan from the connector on the cooling fan cage board.
40 Installing and removing system components
Figure 28. Removing a cooling fan
Next steps
Replace the cooling fan.
Installing a cooling fan
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
Align and slide the cooling fan into the cooling fan cage until the fan clicks into place.
NOTE: Cooling fan is not installed in slot 1 of cooling fan cage assembly.
Installing and removing system components 41
Figure 29. Installing a cooling fan
Next steps
Follow the procedure listed in After working inside your system.
Side wall brackets
Removing the side wall bracket
There are two side wall brackets on either side of the system. The procedure to remove is similar.
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the cooling fan cage assembly.
NOTE: Ensure that you note the routing of the cables as you remove them from the system board. Route the cable
properly when you replace it to prevent the cable from being pinched or crimped.
Steps
1. Press the tab to release the side wall bracket cover.
NOTE: Unroute the cables to release them from the side wall bracket.
2. Release the bracket from the chassis, and lift it away from the system.
42 Installing and removing system components
Figure 30. Removing the side wall bracket
Next steps
Replace the side wall bracket.
Installing the side wall bracket
There are two side wall brackets on either side of the system. The procedure to install is similar.
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If installed, remove the air shroud.
4. Remove the cooling fan cage assembly.
NOTE: Ensure that you note the routing of the cables as you remove them from the system board. Route the cable
properly when you replace it to prevent the cable from being pinched or crimped.
Steps
1. Align the side wall bracket with the tabs on the chassis.
2. Press the side wall bracket with your thumbs until the bracket firmly clicks into place.
NOTE: Route the cables through the side wall bracket.
3. Close the side wall bracket cover with your thumbs until the cover firmly clicks into place.
Installing and removing system components 43
Figure 31. Installing the side wall bracket
Next steps
1. Install the air shroud.
2. Install the cooling fan cage assembly .
3. Follow the procedure listed in the After working inside your system.
Intrusion switch module
This is a service technician replaceable part only.
Removing the intrusion switch module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Disconnect the system power cable from the system board.
Steps
1. Disconnect the intrusion switch cable from the connector on the system board.
NOTE: Observe the routing of the cable as you remove it from the system.
2. Using the Phillips #1 screwdriver, remove the screw securing the intrusion switch module.
44 Installing and removing system components
3. Lift the intrusion switch module out of the system.
Figure 32. Removing the intrusion switch module
Next steps
Replace the intrusion switch module.
Installing the intrusion switch module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the air shroud.
4. Disconnect the system power cable from the system board.
Steps
1. Align and insert the intrusion switch module into the slot on the system until firmly seated.
2. Using the Phillips #1 screwdriver, tighten the screw securing the intrusion switch module.
3. Connect the intrusion switch cable to the connector on the system board.
NOTE: Route the cable properly when you replace it to prevent the cable from being pinched or crimped.
Installing and removing system components 45
Figure 33. Installing the intrusion switch
Next steps
1. Connect the system power cable to the system board.
2. Install the air shroud.
3. Follow the procedure listed in After working inside your system.
Optional serial COM port
This is a service technician replaceable part only.
Removing the optional serial COM port
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Disconnect the serial COM port cable from the connector on the system board.
NOTE: Observe the routing of the cable as you remove it from the system.
2. Open the card holder and lift the serial COM port out of the system.
46 Installing and removing system components
Figure 34. Removing the Serial COM port
3. Install the filler bracket if not replacing the serial COM port.
Next steps
Replace the serial COM port.
Installing the optional serial COM port
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Open the card holder and lift the metal filler bracket from the system.
2. Align and insert the serial COM port into the slot on the system until firmly seated and close the card holder.
3. Connect the serial COM port cable to the connector on the system board.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
Installing and removing system components 47
Figure 35. Installing the Serial COM port
Next steps
1. Follow the procedure listed in After working inside your system.
Drives
Removing a drive blank
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. If installed, remove the front bezel.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
Steps
Press the release button, and slide the drive blank out of the drive slot.
Figure 36. Removing a drive blank
48 Installing and removing system components
Next steps
Installing a drive or replace the drive blank.
Installing a drive blank
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. If installed, remove the front bezel.
Steps
Insert the drive blank into the drive slot until the release button clicks into place.
Figure 37. Installing a drive blank
Next steps
If removed, install the front bezel.
Removing the drive carrier
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. If installed, remove the front bezel.
3. Using the management software, prepare the drive for removal. If the drive is online, the green activity or fault indicator
blinks while the drive is powering off. When the drive indicators are off, the drive is ready for removal. For more information,
see the documentation for the storage controller.
CAUTION: Before attempting to remove or install a drive while the system is running, see the documentation
for the storage controller card to ensure that the host adapter is configured correctly to support drive
removal and insertion.
CAUTION: To prevent data loss, ensure that your operating system supports drive installation. See the
documentation supplied with your operating system.
Steps
1. Press the release button to open the drive carrier release handle.
2. Holding the drive carrier release handle, slide the drive carrier out of the drive slot.
Installing and removing system components 49
Figure 38. Removing a drive carrier
Next steps
Install a drive carrier or install a drive blank.
Installing the drive carrier
Prerequisites
CAUTION: Before removing or installing a drive while the system is running, see the documentation for the
storage controller card to ensure that the host adapter is configured correctly to support drive removal and
insertion.
CAUTION: Combining SAS and SATA drives in the same RAID volume is not supported.
CAUTION: When installing a drive, ensure that the adjacent drives are fully installed. Inserting a drive carrier
and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier's
shield spring and make it unusable.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the
documentation supplied with your operating system.
NOTE: When a replacement hot swappable drive is installed while the system is powered on, the drive automatically begins
to rebuild. Ensure that the replacement drive is blank. Any data on the replacement drive is immediately lost once the drive
is installed
NOTE: Ensure that the drive carrier's release handle is in the open position before inserting the carrier into the slot.
1. Follow the safety guidelines listed in the Safety instructions.
2. If installed, remove the front bezel.
3. Remove the drive carrier or remove the drive blank when you want to assemble the drives in to the system.
Steps
1. Slide the drive carrier into the drive slot.
2. Close the drive carrier release handle to lock the drive in place.
50 Installing and removing system components
Figure 39. Installing a drive carrier
Next steps
If removed, install the front bezel.
Removing the drive from the drive carrier
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Remove the drive carrier
Steps
1. Using a Phillips #1 screwdriver, remove the screws from the slide rails on the drive carrier.
NOTE: If the drive or SSD carrier has Torx screw, use Torx 6 (for 2.5-inch drive) or Torx 8 (for 3.5-inch drive)
screwdriver to remove the drive.
2. Lift the drive out of the drive carrier.
Installing and removing system components 51
Figure 40. Removing the drive from the drive carrier
Next steps
Install the drive into the drive carrier.
Installing the drive into the drive carrier
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Remove the drive carrier
Steps
1. Insert the drive into the drive carrier with the drive connector facing towards the rear of the carrier.
2. Align the screw holes on the drive with the screws holes on the drive carrier.
3. Using a Phillips #1 screwdriver, secure the drive to the drive carrier with the screws.
NOTE: If the drive or SSD carrier has Torx screw, use Torx 6 (for 2.5-inch drive) or Torx 8 (for 3.5-inch drive)
screwdriver to install the drive.
52 Installing and removing system components
Figure 41. Installing a drive into the drive carrier
Next steps
1. Install the drive carrier.
Drive backplane
This is a service technician replaceable part only.
Drive backplane
Depending on your system configuration, the drive backplanes supported are listed here:
Table 15. Supported backplane options
System Supported drives options
PowerEdge R550
16 x 2.5-inch SAS/SATA backplane
8 x 2.5-inch SAS/SATA backplane
8 x 3.5-inch SAS/SATA backplane
Figure 42. 16x 2.5-inch SAS/SATA backplane
1. BP_DST_SB1
2. BP_PWR_CTRL (backplane power and signal cable to system board)
3. BP_DST_SB1
Installing and removing system components 53
4. BP_PWR_1 (backplane power to system board)
Figure 43. 8 x 2.5-inch drive backplane
1. BP_PWR_CTRL 2. BP_DST_SA1 (PERC to backplane)
3. BP_DST_PA1 (PCIe connector) 4. BP_ DST_PB1 (PCIe connector)
5. BP_ DST_PA2 (PCIe connector) 6. BP_PWR_1 (backplane power and signal cable to system
board)
7. BP_DST_PB2 (PCIe connector)
Figure 44. 8x 3.5-inch drive backplane
1. BP_DST_SB1
2. BP_PWR_1 (backplane power and signal cable to system board)
3. BP_DST_SA1
Removing the drive backplane
Prerequisites
CAUTION: To prevent damage to the drives and backplane, remove the drives from the system before removing
the backplane.
CAUTION: Note the number of each drive and temporarily label them before you remove the drive so that you
can reinstall them in the same location.
NOTE: The procedure to remove the backplane is similar for all backplane configurations.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
5. Remove the cooling fan cage assembly.
6. Remove the PERC card.
7. Remove the drives.
8. If installed, disconnect the optical drive signal and power cables from the system.
9. Disconnect the drive backplane cables from the connectors on the system board.
54 Installing and removing system components
Steps
1. Press the blue release tabs to disengage the drive backplane from the hooks on the system.
2. Lift the drive backplane out of the system.
NOTE: To avoid damaging the backplane, ensure that you move the control panel cables from the cable routing clips
before removing the backplane.
Figure 45. Removing the drive backplane
Next steps
Replace the drive backplane.
Installing the drive backplane
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
5. Remove the cooling fan cage assembly.
6. Remove the PERC card.
7. Remove the drives.
NOTE: To avoid damaging the backplane, ensure to move the control panel cables from the cable routing clips before
removing the backplane.
NOTE: Route the cable properly when you replace it to prevent the cable from being pinched or crimped.
Steps
1. Use the hooks on the system as guides to align the slots on the backplane with the guides on the system.
2. Slide the drive backplane into the guides and lower the backplane until the blue release tabs click into place.
Installing and removing system components 55
Figure 46. Installing the drive backplane
Next steps
1. If removed, connect the optical drive signal and power cables to the system.
2. Connect the drive backplane cables to the connectors on the system board.
3. Install the drives.
4. Install the PERC card.
5. Install the cooling fan cage assembly.
6. Install the drive backplane cover.
7. Install the air shroud.
8. Follow the procedure listed in After working inside your system.
56 Installing and removing system components
Cable routing
Figure 47. 8 x 2.5-inch SAS/SATA
Table 16. 8 x 2.5-inch SAS/SATA
From To
CTRL_DST_PA1 (Signal connector on the front PERC) SL3_CPU1_PB2 (Signal connector on system board)
BP_PWR_1 (Power connector on backplane) SIG_PWR_3 (Power connector on system board)
BOSS_PWR (BOSS card power connector) BOSS_PWR (Power connector for BOSS card on system
board)
SL10_PCH_PA5 (BOSS signal connector on system board) BOSS signal on BOSS S2 card module
Figure 48. 8 x 3.5-inch SAS/SATA
Installing and removing system components 57
Table 17. 8 x 3.5-inch SAS/SATA
From To
CTRL_DST_PA1 (Signal connector on the front PERC) SL3_CPU1_PB2 (Signal connector on system board)
BP_PWR_1 (Power connector on backplane) SIG_PWR_3 (Power connector on system board)
BOSS_PWR (BOSS card power connector) BOSS_PWR (Power connector for BOSS card on system
board)
SL10_PCH_PA5 (BOSS signal connector on system board) BOSS signal on BOSS S2 card module
Figure 49. 16 x 2.5-inch SAS/SATA
Table 18. 16 x 2.5-inch SAS/SATA
From To
CTRL_SRC_SB1 (Signal connector on the front PERC) BP_DST_SB1 (Signal connector on backplane)
CTRL_DST_PA1 (Signal connector on the front PERC) SL3_CPU1_PB2 (Signal connector on system board)
BP_PWR_1 (Power connector on backplane) SIG_PWR_3 (Power connector on system board)
BOSS_PWR (BOSS card power connector) BOSS_PWR (Power connector for BOSS card on system
board)
SL10_PCH_PA5 (BOSS signal connector on system board) BOSS signal on BOSS S2 card module
58 Installing and removing system components
Figure 50. ODD and no PERC configuration
Table 19. ODD and no PERC configuration
From To
CTRL_SRC_SB1 (Signal connector on the front PERC) BP_DST_SB1 (Signal connector on backplane)
CTRL_DST_SA1 (Signal connector on the drive backplane) SL9_PCH_SA1 (Signal connector on system board)
ODD (Optical Disk Drive connector on system board) ODD (Optical Disk Drive)
ODD_PWR_1 (ODD card power connector) SIG_PWR_3 (Power connector on system board)
BP_PWR_1 (Power connector on backplane) SIG_PWR_3 (Power connector on system board)
BOSS_PWR (BOSS card power connector) BOSS_PWR (Power connector for BOSS card on system
board)
SL10_PCH_PA5 (BOSS signal connector on system board) BOSS signal on BOSS S2 card module
Installing and removing system components 59
Figure 51. VGA and Control Panel
Table 20. VGA and Control Panel
From To
LEFT_CP (Left control panel connector) Left control panel (LCP)
RGT_CP (Right control panel connector) Right control panel (RCP)
FRONT_VIDEO (Front VGA connector) VGA on RCP
System memory
System memory guidelines
The PowerEdge R550 system supports DDR4 registered DIMMs (RDIMMs). System memory holds the instructions that are
executed by the processor.
Your system contains 16 memory sockets organized into 8 channels per processor.
Memory channels are organized as follows:
Table 21. Memory channels
Processor Channel A Channel B Channel C Channel D Channel E Channel F Channel G Channel H
Processor 1 A1 A5 A3 A7 A2 A6 A4 A8
Processor 2 B1 B5 B3 B7 B2 B6 B4 B8
60 Installing and removing system components
Figure 52. Memory channels
Table 22. Supported memory matrix
DIMM type Rank Capacity DIMM rated voltage and speed Operating speed for
DIMMs per Channel
(DPC)
RDIMM 1R 8 GB DDR4 (1.2V), 3200 MT/s 2933 MT/s
2R 16 GB, 32 GB, 64 GB DDR4 (1.2V), 3200 MT/s 2933 MT/s
General memory module installation guidelines
To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory.
If your system's memory configurations fail to observe these guidelines, your system might not boot, stop responding during
memory configuration, or operate with reduced memory.
The memory bus may operate at speeds of 2933 MT/s depending on the following factors:
●System profile selected (for example, Performance Optimized, or Custom [can be run at high speed or lower])
●Maximum supported DIMM speed of the processors
●Maximum supported speed of the DIMMs
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
The system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset
architectural configuration. The following are the recommended guidelines for installing memory modules:
●All DIMMs must be DDR4.
●x4 and x8 DRAM based memory modules can be mixed.
●If memory modules with different speeds are installed, they operate at the speed of the slowest installed memory module(s).
●Populate memory module sockets only if a processor is installed.
○For single-processor systems, sockets A1 to A8 are available.
○For dual-processor systems, sockets A1 to A8 and sockets B1 to B8 are available.
Installing and removing system components 61
●In Optimizer Mode, the DRAM controllers operate independently in the 64-bit mode and provide optimized memory
performance.
Table 23. Memory population rules
Processor Configuration Memory population Memory population
information
Single processor Optimizer (Independent
channel) population order
A{1}, A{2}, A{3}, A{4}, A{5}, A{6},
A{7}, A{8}
1, 2, 3, 4 DIMMs are
allowed.
Dual processor (Start with
processor1. Processor 1
and processor 2 population
should match)
Optimizer (Independent
channel) population order
A{1}, B{1}, A{2}, B{2}, A{3}, B{3},
A{4}, B{4}, A{5}, B{5}, A{6}, B{6},
A{7}, B{7} A{8}, B{8}
1, 2, 3, 4, 5, 6, 7, 8 DIMMs
are supported per system .
NOTE: Optimizer
population order is not
traditional for 8 and 16
DIMMs installations for
dual processor.
●Memory modules of different capacities can be mixed provided other memory population rules are followed.
●Mixing of more than two memory module capacities in a system is not supported.
●Unbalanced or odd memory configuration results in a performance loss and system may not identify the memory modules
being installed, so always populate memory channels identically with equal DIMMs for best performance.
●Supported RDIMM / LRDIMM configurations are 1, 2, 4, 6, 8 DIMMs per processor.
●Populate eight equal memory modules per processor (one DIMM per channel) at a time to maximize performance.
NOTE: Equal memory modules refer to DIMMs with identical electrical specification and capacity that may be from
different vendors.
Removing a memory module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
WARNING: The memory modules are hot to touch for some time after the system has been powered off. Allow
the memory modules to cool before handling them.
Steps
1. Locate the appropriate memory module socket.
2. To release the memory module from the socket, simultaneously press the ejectors on both ends of the memory module
socket to fully open.
CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the
memory module or metallic contacts.
3. Lift the memory module away from the system.
62 Installing and removing system components
Figure 53. Removing a memory module
Next steps
Replace the memory module.
Installing a memory module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
Steps
1. Locate the appropriate memory module socket.
CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the
memory module or metallic contacts.
2. If a memory module blank is installed in the socket, remove it.
NOTE: Ensure the socket ejector latches are fully open, before installing the memory module.
3. Align the edge connector of the memory module with the alignment key of the memory module socket, and insert the
memory module in the socket.
CAUTION: To prevent damage to the memory module or the memory module socket during installation, do
not bend or flex the memory module; insert both ends of the memory module simultaneously.
NOTE: The memory module socket has an alignment key that enables you to install the memory module in the socket in
only one orientation.
CAUTION: Do not apply pressure at the center of the memory module; apply pressure at both ends of the
memory module evenly.
Installing and removing system components 63
4. Press the memory module with your thumbs until the ejectors firmly click into place. When the memory module is properly
seated in the socket, the levers on the memory module socket align with the levers on the other sockets that have memory
modules installed.
Figure 54. Installing a memory module
Next steps
1. Install the air shroud.
2. Follow the procedure listed in After working inside your system.
3. To verify if the memory module has been installed properly, press F2 and navigate to System Setup Main Menu > System
BIOS > Memory Settings. In the Memory Settings screen, the System Memory Size must reflect the updated capacity of
the installed memory.
4. If the System Memory Size is incorrect, one or more of the memory modules may not be installed properly. Ensure that the
memory modules are firmly seated in their sockets.
5. Run the system memory test in system diagnostics.
Processor and heat sink module
This is a service technician replaceable part only.
Removing processor and heat sink module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
NOTE: The heat sink and processor are too hot to touch for some time after the system has been powered down. Allow
the heat sink and processor to cool down before handling them.
Steps
1. Ensure all four anti-tilt wires are in the locked position (outward position), and then using a Torx #T30 tool, loosen the
captive nuts on the processor heat sink module (PHM) in the order that is mentioned below:
64 Installing and removing system components
a. Loosen the first nut three turns.
b. Loosen the nut diagonally opposite to the nut you loosened first.
c. Repeat the procedure for the remaining two nuts.
d. Return to the first nut to loosen it completely.
2. Set all the anti-tilt wires to unlocked position (inward position).
Figure 55. Loosening the nuts and setting the anti-tilt wires to the unlock position
3. Lift the PHM from the system and set the PHM aside with the processor side facing up.
Figure 56. Removing a processor heat sink
Installing and removing system components 65
Next steps
If you are removing a faulty heat sink, replace the heat sink, if not, remove the processor.
Removing the processor from the processor and heat sink module
Prerequisites
WARNING: The heat sink may be hot to touch for some time after the system has been powered off. Allow the
heat sink to cool before removing it.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the processor heat sink module.
CAUTION: You may find the CMOS battery loss or CMOS checksum error displayed during the first instance of
powering on the system after the processor or system board replacement which is expected. To fix this, simply
go to setup option to configure the system settings.
Steps
1. Place the heat sink with the processor side facing up.
2. Using your thumb, lift the thermal interface material (TIM) break lever to release the processor from the TIM and retaining
clip.
3. Holding the processor by the edges, lift the processor away from the retaining clip.
NOTE: Ensure to hold the retaining clip to the heat sink as you lift the TIM break lever.
Figure 57. Lift up the TIM break lever
66 Installing and removing system components
Figure 58. Aligning pin 1 marks of processor with tray
NOTE: Ensure to return the TIM break lever back to original position.
4. Using your thumb and index finger, first hold the retaining clip release tab at the pin 1 connector, pull out the tip of the
retaining clip release tab, and then lift the retaining clip partially from the heat sink.
5. Repeat the procedure at the remaining three corners of the retaining clip.
6. After all the corners are released from the heat sink, lift the retaining clip from the pin 1 corner of the heat sink.
Installing and removing system components 67
Figure 59. Removing the retaining clip
Next steps
Replace the processor into a processor and heat sink module (PHM).
Installing the processor into a processor and heat sink module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the processor heat sink module.
Steps
1. Place the processor in the processor tray with the connector side facing down.
NOTE: Ensure that the pin 1 indicator on the processor tray is aligned with the pin 1 indicator on the processor.
2. Place the retaining clip on top of the processor in the processor tray aligning pin 1 indicator on the processor.
NOTE: Ensure the pin 1 indicator on the retaining clip is aligned with the pin 1 indicator on the processor before placing
the retaining clip on the processor
NOTE: Before you install the heat sink, ensure to place the processor and retaining clip in the tray
68 Installing and removing system components
Figure 60. Installing the processor bracket
3. Align the processor with retaining clip, by using the fingers press the retaining clip on all the four sides until it clicks into
place.
NOTE: Ensure the processor is securely latched to the retaining clip.
Figure 61. Press the retaining clip on the four sides
4. If you are using an existing heat sink, remove the thermal grease from the heat sink by using a clean lint-free cloth.
5. Use the thermal grease syringe included with your processor kit to apply the grease in a thin spiral on the bottom of the heat
sink.
Installing and removing system components 69
CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and
contaminating the processor socket.
NOTE: The thermal grease syringe is intended for single use only. Dispose the syringe after you use it.
Figure 62. Applying thermal grease
6. For new heat sink, remove the Thermal Interface Material (TIM) protective film from the base of heat sink.
70 Installing and removing system components
Figure 63. Remove the Thermal Interface Material (TIM) protective film
7. Place the heat sink on the processor and press the base of the heat sink until the retaining clip locks onto the heat sink at all
the four corners.
CAUTION: To avoid damaging the fins on the heat sink, do not press down on the heat sink fins.
NOTE:
●Ensure latching features on retaining clip and heat sink are aligned during assembly.
●Ensure that the pin 1 indicator on the heat sink is aligned with the pin 1 indicator on the retaining clip before placing
the heat sink onto the retaining clip.
Installing and removing system components 71
Figure 64. Installing the heat sink onto the processor
Next steps
1. Install the processor and heat sink module.
2. Install the air shroud.
3. Follow the procedure listed in After working inside your system.
Installing the processor heat sink module
Prerequisites
Never remove the heat sink from a processor unless you intend to replace the processor or system board. The heat sink is
necessary to maintain proper thermal conditions.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. If installed, remove the processor dust cover.
Steps
1. Set the anti-tilt wires to the unlocked position on the heat sink (inward position).
2. Align the pin 1 indicator of the processor heat sink module (PHM) to the system board, and then place the PHM on the
processor socket.
CAUTION: To avoid damaging the fins on the heat sink, do not press down on the heat sink fins.
NOTE: Ensure that the PHM is held parallel to the system board to prevent damaging the components.
72 Installing and removing system components
Figure 65. Installing the processor heat sink module
3. Set the anti-tilt wires to the locked position (outward position), and then using the Torx #T30 tool, tighten the captive nuts
(8 in-lbf) on the PHM in the order below:
a. In a random order, tighten the first nut three turns.
b. Tighten the nut diagonally opposite to the nut you tighten first.
c. Repeat the procedure for the remaining two nuts.
d. Return to the first nut to tighten it completely.
e. Check all the nuts to ensure they are firmly secured.
Installing and removing system components 73
Figure 66. Setting the anti-tilt wires to the locked position and tighten the nuts
Next steps
1. Install the air shroud.
2. Follow the procedure listed in the After working inside your system.
Expansion cards
NOTE: When an expansion card is not supported or missing, the iDRAC and Lifecycle Controller logs an event. This does
not prevent your system from booting. However, if a F1/F2 pause occurs with an error message, see Troubleshooting
expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/poweredgemanuals.
74 Installing and removing system components
Expansion card installation guidelines
Figure 67. Expansion card slot connectors
1. Slot 1
2. Slot 2
3. Slot 5
4. Slot 6
The following table describes the expansion card configurations:
Table 24. Supported configurations
Configurations Expansion card
risers
PCIe Slots Controlling
processor
Height Length Slot width
Config 0 N/A 1 Processor 1 Low profile Half length x16
2 PCH Low profile Half length x4
5 Processor 2 Low profile Half length x16
6 Processor 2 Low profile Half length x16
Config 0-1 N/A 1 Processor 1 Low profile Half length x16
2 PCH Low profile Half length x4
NOTE: The expansion-card slots are not hot-swappable.
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion
cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be
installed in the card priority and slot priority order.
Installing and removing system components 75
Table 25. Configuration 0
Card type Slot priority Maximum number of cards
Dell Serial port module (LP) 1 1
fPERC Integrated slot 1
Internal PERC adapter 1 1
fPERC11 H355, Front Integrated slot 1
12Gbps SAS HBA 1 1
Intel (NIC: 100Gb) 5, 6, 1 3
Mellanox (NIC: 100Gb) 5, 6, 1 3
Broadcom (NIC: 25Gb) 5, 6, 1, 2 1
Intel (NIC: 25Gb) 5, 6, 1, 2 1
Mellanox (NIC: 25Gb) Not supported N/a
Mellanox (NIC: 25Gb, LP) 1, 6, 5 3
Qlogic (NIC: 25Gb) 5, 6, 1, 2 1
SolarFlare (NIC: 25Gb) 5, 6, 1, 2 4
Broadcom (NIC: 10Gb) 5, 6, 1, 2 4
Intel (NIC: 10Gb) 5, 6, 1, 2 4
Qlogic (NIC: 10Gb) 5, 6, 1, 2 4
Broadcom (NIC: 1Gb) 5, 6, 1, 2 4
Intel (NIC: 1Gb) 5, 6, 1, 2 4
Mellanox (NIC: HDR100 VPI) Not supported N/a
Mellanox (NIC: HDR VPI) Not supported N/a
Broadcom (OCP: 25Gb) Integrated slot 1
Mellanox (OCP 3: 25Gb) Integrated slot 1
Intel (OCP: 25Gb) Integrated slot 1
Marvell (OCP: 25Gb) Integrated slot 1
Mellanox (OCP: 25Gb) Integrated slot 1
SolarFlare (OCP: 25Gb) Integrated slot 1
Broadcom (OCP: 10Gb) Integrated slot 1
Marvell (OCP: 10Gb) Integrated slot 1
Intel (OCP: 10Gb) Integrated slot 1
Broadcom (OCP: 1Gb) Integrated slot 1
Intel (OCP: 1Gb) Integrated slot 1
Dell External PERC Adapter 5, 6, 1, 2 4
Dell BOSS S1 Module Integrated slot 1
Samsung (PCIe SSD AIC) 5, 6, 1, 2 4
Intel (PCIe SSD) Not supported N/a
76 Installing and removing system components
Table 26. Configuration0-1
Card type Slot priority Maximum number of cards
Dell Serial port module (LP) 1 1
fPERC Integrated slot 1
Internal PERC adapter 1 1
fPERC11 H355, Front Integrated slot 1
12Gbps SAS HBA 1 1
Intel (NIC: 100Gb) 1 1
Mellanox (NIC: 100Gb) 1 1
Broadcom (NIC: 25Gb) 1, 2 1
Intel (NIC: 25Gb) 1, 2 1
Mellanox (NIC: 25Gb) Not supported N/a
Mellanox (NIC: 25Gb, LP) 1 1
Qlogic (NIC: 25Gb) 1, 2 1
SolarFlare (NIC: 25Gb) 1, 2 4
Broadcom (NIC: 10Gb) 1, 2 4
Intel (NIC: 10Gb) 1, 2 4
Qlogic (NIC: 10Gb) 1, 2 4
Broadcom (NIC: 1Gb) 1, 2 4
Intel (NIC: 1Gb) 1, 2 4
Mellanox (NIC: HDR100 VPI) Not supported N/a
Mellanox (NIC: HDR VPI) Not supported N/a
Broadcom (OCP: 25Gb) Integrated slot 1
Intel (OCP: 25Gb) Integrated slot 1
Marvell (OCP: 25Gb) Integrated slot 1
Mellanox (OCP: 25Gb) Integrated slot 1
Mellanox (OCP 3: 25Gb) Integrated slot 1
SolarFlare (OCP: 25Gb) Integrated slot 1
Broadcom (OCP: 10Gb) Integrated slot 1
Marvell (OCP: 10Gb) Integrated slot 1
Intel (OCP: 10Gb) Integrated slot 1
Broadcom (OCP: 1Gb) Integrated slot 1
Intel (OCP: 1Gb) Integrated slot 1
Dell External PERC Adapter 1, 2 4
Dell BOSS S1 Module Integrated slot 1
Samsung (PCIe SSD AIC) 1, 2 4
Intel (PCIe SSD) Not supported N/a
Installing and removing system components 77
Removing the expansion card
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If required, remove the air shroud.
Steps
1. Rotate to open the PCIe card holder.
2. Disconnect the cables form the expansion card.
3. By holding the edges lift the expansion card from the PCIe slot on the system board
Figure 68. Removing the expansion card
4. Install the metal filler bracket if not replacing the expansion card.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
78 Installing and removing system components
Figure 69. Installing the filler bracket
Next steps
Replace the expansion card.
Installing the expansion card
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If required, remove the air shroud.
Steps
1. Rotate to open the PCIe card holder.
2. If Installed, lift the metal filler bracket from the system.
NOTE: Store the riser blanks for future use. Filler brackets must be installed in empty expansion card slots to maintain
Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the
system and aid in proper cooling and airflow inside the system.
Installing and removing system components 79
Figure 70. Removing the filler bracket
3. Holding the edges, align the expansion card with the slot on the system.
4. Lower the expansion card into the place and press until the expansion card is fully seated on the PCIe slot.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 71. Installing the expansion card
Next steps
1. If removed, install the air shroud.
2. Follow the procedure listed in After working inside your system.
80 Installing and removing system components
Optional IDSDM module
Removing the IDSDM module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If you are replacing the IDSDM card, remove the MicroSD cards.
NOTE: Temporarily label each SD card with its corresponding slot number before removal. Reinstall the SD cards into
the corresponding slots.
Steps
Holding the blue pull tab, lift the IDSDM card out of the system.
Figure 72. Removing the IDSDM module
Next steps
Replace the IDSDM module.
Installing the IDSDM module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Locate the IDSDM connector on the system board.
To locate IDSDM, see the System board jumpers and connectors section.
2. Align IDSDM module with the connector on the system board.
Installing and removing system components 81
3. Press the IDSDM module, until firmly seated on the system board connector.
Figure 73. Installing the IDSDM module
Next steps
1. Install the MicroSD cards.
NOTE: Reinstall the MicroSD cards into the same slots based on the labels you had marked on the cards during removal.
2. Follow the procedure listed in the After working inside your system.
Optional BOSS S2 card
Removing the BOSS S2 module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If required, remove the air shroud.
Steps
1. Pull and lift the BOSS S2 card carrier retention latch lock to open.
2. Slide the BOSS S2 card carrier out.
82 Installing and removing system components
Figure 74. Removing the BOSS S2 card carrier
3. Using the Phillips #1 screwdriver remove the M3 x 0.5 x 4.5 mm screw that secures the M.2 SSD to the BOSS S2 card
carrier.
4. Slide the M.2 SSD out from the BOSS S2 card carrier.
Figure 75. Removing the M.2 SSD
5. Disconnect the BOSS power cable from the PIB and the BOSS signal cable from the motherboard.
Installing and removing system components 83
Figure 76. Disconnecting the BOSS power cable and signal cable
6. Using the Phillips #1 screwdriver remove the two M3 x 0.5 x 4.5 mm screws that secure the BOSS S2 module on the BOSS
module bay.
7. Slide out the BOSS S2 module from the BOSS module bay.
Figure 77. Removing the BOSS S2 module
8. Remove the BOSS power cable and BOSS signal cable from the BOSS S2 controller card module.
Figure 78. Removing the BOSS power cable and BOSS signal cable
84 Installing and removing system components
9. Using the Phillips #1 screwdriver, remove the M3 x 0.5 x 4.5 mm screw that secures the BOSS cover on the BOSS S2
module. Slide the BOSS cover out from the BOSS S2 module.
Figure 79. Removing the BOSS cover
Next steps
1. Replace the BOSS S2 module.
Installing the BOSS S2 module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If required, remove the air shroud.
Installing and removing system components 85
Steps
1. Slide the BOSS cover on the BOSS S2 module. Using the Phillips #1 screwdriver, secure the BOSS cover on the BOSS S2
module with the M3 x 0.5 x 4.5 mm screw.
Figure 80. Installing the BOSS cover
2. Connect the BOSS power cable and BOSS signal cable to the BOSS S2 module.
Figure 81. Connecting the BOSS power cable and BOSS Signal cable to the BOSS S2 module
3. Slide the BOSS S2 module into the BOSS module bay until it is firmly seated.
4. Using the Phillips #1 screwdriver, secure the BOSS S2 module on the BOSS module bay with the two M3 x 0.5 x 4.5 mm
screws.
86 Installing and removing system components
Figure 82. Installing the BOSS S2 module
5. Connect the BOSS power cable to the PIB and the BOSS signal cable to the motherboard.
Figure 83. Connecting the BOSS power cable and signal cable
6. Align the M.2 SSD at an angle with the BOSS S2 card carrier.
7. Insert the M.2 SSD until it is firmly seated in the BOSS S2 card carrier.
8. Using the Phillips #1 screwdriver, secure the M.2 SSD on the BOSS S2 card carrier with the M3 x 0.5 x 4.5 mm screw.
Installing and removing system components 87
Figure 84. Installing the M.2 SSD
9. Slide the BOSS S2 card carrier into the BOSS S2 module slot.
10. Close the BOSS S2 card carrier release latch to lock the carrier in place.
Figure 85. Installing the BOSS S2 card carrier
Next steps
1. If removed, install the air shroud.
2. Follow the procedure listed in the After working inside your system.
Front mounting front PERC module
This is a service technician replaceable part only.
Removing the front mounting front PERC module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
88 Installing and removing system components
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
5. Remove the cooling fan cage assembly.
6. Disconnect the PERC cable from the system board connector, observe the cable routing.
Steps
1. Using a Phillips #2 screwdriver, loosen the captive screws on the front PERC module.
2. Pull the front PERC module to disengage from the connector on the drive backplane.
3. Llift the front PERC module out of the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 86. Removing the front mounting front PERC module
Next steps
1. Replace the front mounting front PERC module.
Installing the front mounting front PERC module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
5. Remove the cooling fan cage assembly.
6. Route the cable properly to prevent the cable from being pinched or crimped.
Steps
1. Align the front PERC module at an angle until the tray touches the slot in the system.
2. Press the front PERC module connector with the connector on the drive backplane until firmly seated.
3. Using a Phillips #2 screwdriver, tighten the captive screws on the front PERC module.
Installing and removing system components 89
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 87. Installing the front mounting front PERC module
Next steps
1. Connect the PERC cables to the backplane and system board connectors.
2. Install the cooling fan cage assembly.
3. Install the drive backplane cover.
4. Install the air shroud.
5. Follow the procedure listed in After working inside your system.
Optional OCP card
Removing the OCP shroud
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
Hold the edges of the OCP shroud and lift the shroud at an angle out of the system.
90 Installing and removing system components
Figure 88. Removing the OCP shroud
Next steps
Replace the OCP shroud.
Installing the OCP shroud
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Place the OCP shroud at an angle and align the slot on the OCP shroud with the standoff on the system.
2. Lower and press the OCP shroud until it clicks into place.
Figure 89. Installing the OCP shroud
Installing and removing system components 91
Next steps
1. Follow the procedure listed in After working inside your system.
Removing the OCP card
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the OCP shroud.
Steps
1. Open the blue latch to disengage the OCP card.
2. Push the OCP card towards the rear end of the system to disconnect from the connector on the system board.
3. Slide the OCP card out of the slot on the system.
92 Installing and removing system components
Figure 90. Removing the OCP card
4. If the OCP card is not going to be replaced, install a filler bracket.
Next steps
Replace the OCP card.
Installing the OCP card
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the OCP shroud.
Steps
1. If installed, remove the filler bracket.
2. Open the blue latch on the system board.
3. Slide the OCP card into the slot in the system.
4. Push until the OCP card is connected to the connector on the system board.
5. Close the blue latch to lock the OCP card to the system.
Figure 91. Installing the OCP card
Installing and removing system components 93
Next steps
1. Install the OCP shroud.
2. Follow the procedure listed in After working inside your system.
System battery
This is a service technician replaceable part only.
Replacing the system battery
Prerequisites
WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only
with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the
manufacturer's instructions. See the Safety instructions that came with your system for more information.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. If required, move aside the cable that pass over the battery.
Steps
1. To remove the battery:
a. Use a plastic scribe to pry out the system battery.
94 Installing and removing system components
Figure 92. Removing the system battery
CAUTION: To avoid damage to the battery connector, you must firmly support the connector while installing
or removing a battery.
2. To install a new system battery:
a. Hold the battery with the positive side facing up and slide it under the securing tabs.
b. Press the battery into the connector until it snaps into place.
Figure 93. Installing the system battery
Next steps
1. Follow the procedure listed in the After working inside your system.
2. Confirm that the battery is operating properly, by performing the following steps:
Installing and removing system components 95
a. Enter the System Setup, while booting, by pressing F2.
b. Enter the correct time and date in the System Setup Time and Date fields.
c. Exit the System Setup.
d. To test the newly installed battery, remove the system from the enclosure for at least an hour.
e. Reinstall the system into the enclosure after an hour.
f. Enter the System Setup and if the time and date are still incorrect, see Getting help section.
Optional internal USB card
NOTE: To locate the internal USB port on the system board, see the System board jumpers and connectors section.
Removing the internal USB card
Prerequisites
CAUTION: To avoid interference with other components in the server, the maximum permissible dimensions of
the USB memory key are 15.9 mm width x 57.15 mm length x 7.9 mm height.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Holding the blue tag, lift the internal USB card to disconnect from the connector on the system board.
2. Remove the USB memory key from the internal USB card.
Figure 94. Removing the internal USB card
Next steps
Replace the internal USB card.
96 Installing and removing system components
Installing the internal USB card
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Connect the USB key to the internal USB card.
NOTE: For information on the exact location of USB on system board, see System board jumpers and connectors
section
2. Align the internal USB card with the connector on the system board and press firmly until the internal USB card is seated.
Figure 95. Installing the internal USB card
Next steps
1. Follow the procedure listed in After working inside your system.
2. While booting, press F2 to enter System Setup and verify that the system detects the USB memory key.
MicroSD card
Removing the MicroSD card
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the IDSDM module.
Installing and removing system components 97
Steps
1. Locate the MicroSD card slot on the IDSDM module, and press the card to partially release it from the slot. For more
information on the slot location, see System board jumpers and connectors section.
2. Hold the MicroSD card and remove it from the slot.
NOTE: Temporarily label each MicroSD card with its corresponding slot number after removal.
Figure 96. Removing the MicroSD card
Next steps
Replace the MicroSD cards.
Installing the MicroSD card
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
NOTE: To use an MicroSD card with your system, ensure that the Internal SD Card Port is enabled in System Setup.
NOTE: Ensure that you install the MicroSD cards into the same slots based on the labels you had marked on the cards
during removal.
Steps
1. Locate the MicroSD card slot on the IDSDM module. Orient the MicroSD card appropriately and insert the contact-pin end of
the card into the slot. To locate IDSDM, see the System board jumpers and connectors section.
NOTE: The slot is keyed to ensure correct insertion of the card.
2. Press the card into the slot to lock it into place.
98 Installing and removing system components
Figure 97. Installing the MicroSD card
Next steps
1. Install the IDSDM module.
2. Follow the procedure listed in the After working inside your system.
Power supply unit
NOTE: While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For updating to the latest firmware and changing the configuration, see the
Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals.
NOTE: For information about DC PSU cabling instructions, see the Cabling instructions for – (48 – 60) V DC power supply
Tech sheet that is shipped with your DC PSU.
Hot spare feature
Your system supports the hot spare feature that significantly reduces the power overhead associated with the power supply
unit (PSU) redundancy.
When the hot spare feature is enabled, one of the redundant PSUs is switched to the sleep state. The active PSU supports 100
percent of the system load, thus operating at higher efficiency. The PSU in the sleep state monitors output voltage of the active
PSU. If the output voltage of the active PSU drops, the PSU in the sleep state returns to an active output state.
If having both PSUs active is more efficient than having one PSU in the sleep state, the active PSU can also activate the
sleeping PSU.
The default PSU settings are as follows:
●If the load on the active PSU is more than 50 percent of PSU rated power wattage, then the redundant PSU is switched to
the active state.
●If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to
the sleep state.
You can configure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC User’s Guide
available at www.dell.com/poweredgemanuals.
Installing and removing system components 99
Removing a power supply unit blank
Prerequisites
Follow the safety guidelines listed in the Safety instructions.
Steps
Pull the blank out of the system.
CAUTION: To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a
non-redundant configuration. Remove the PSU blank only if you are installing a second PSU.
Figure 98. Removing a power supply unit blank
Next steps
Replace the PSU blank or install the PSU.
Installing a power supply unit blank
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
NOTE: Install the power supply unit (PSU) blank only in the second PSU bay.
2. Remove the PSU.
Steps
Align the PSU blank with the PSU bay and push it into the PSU bay until it clicks into place.
Figure 99. Installing a power supply unit blank
100 Installing and removing system components
Removing a power supply unit
Prerequisites
CAUTION: The system requires one power supply unit (PSU) for normal operation. On power-redundant
systems, remove and replace only one PSU at a time in a system that is powered on.
1. Follow the safety guidelines listed in the Safety instructions.
2. Disconnect the power cable from the power outlet and from the Power Supply Unit (PSU) you intend to remove.
3. Remove the cable from the strap on the PSU handle.
4. Unlatch and lift the optional cable management arm if it interferes with the PSU removal.
For information about the cable management arm, see the system’s rack documentation at https://www.dell.com/
poweredgemanuals.
Steps
Press the orange release latch, and holding the PSU handle slide the PSU out of the PSU bay.
Figure 100. Removing a power supply unit
Next steps
Replace the PSU or install the PSU blank.
Installing a power supply unit
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. For systems that support redundant Power Supply Units (PSUs), ensure that both the PSUs are of the same type and have
the same maximum output power.
NOTE: The maximum output power (shown in watts) is listed on the PSU label.
3. Remove the PSU blank.
Steps
Slide the PSU into the PSU bay until the release latch snaps into place.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Installing and removing system components 101
Figure 101. Installing a power supply unit
Next steps
1. If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the
system’s rack documentation at https://www.dell.com/poweredgemanuals.
2. Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION: When connecting the power cable to the PSU, secure the cable to the PSU with the strap.
NOTE: When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds for the system to recognize the
PSU and determine its status. The PSU redundancy may not occur until discovery is complete. The PSU status indicator
turns green to indicate that the PSU is functioning properly.
NOTE: For certain premium configurations with high power consumption, system PSU might stay with 2+0 mode only, 1+1
redundant mode is not available.
NOTE: While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the
Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals
Power interposer board
This is a service technician replaceable part only.
Removing the power interposer board
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the PSU.
5. Disconnect the cables that are connected to power interposer board (PIB) and observe the cable routing.
Steps
1. Using a Phillips #2 screwdriver, remove the screws securing the PIB to the system.
2. Lift the PIB away from the system.
102 Installing and removing system components
Figure 102. Removing the power interposer board
Next steps
Replace the power interposer board.
Installing the power interposer board
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the PSU.
5. Disconnect the cables that are connected to power interposer board (PIB) and observe the cable routing.
Steps
1. Align the slots on the power interposer board (PIB) with the hook on the system and lower it into place.
2. Using Phillips #2 screwdriver, tighten the screws to secure the PIB to the system.
Installing and removing system components 103
Figure 103. Installing the power interposer board
Next steps
1. Connect the cables to the PIB and route them properly.
2. Install the PSU.
3. Install the air shroud.
4. Follow the procedure listed in After working inside your system.
Cooling fan cage board
Removing the cooling fan cage board
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the following components:
a. Air shroud
b. Cooling fan cage assembly
4. Disconnect cables from the fan board.
Steps
1. Using a Phillips #2 screwdriver. remove the screws that secures the fan board to the system.
2. Holding the edges lift the fan board out of the system.
104 Installing and removing system components
Figure 104. Removing the cooling fan cage board.
Next steps
Replace the cooling fan cage board.
Installing the cooling fan cage board
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the following components:
a. Air shroud
b. Cooling fan cage assembly
4. Disconnect cables from the fan board.
Steps
1. Align and lower the fan board with the screw holes in the system.
2. Using a Phillips #2 screwdriver. tighten the screws that secures the fan board to the system
Installing and removing system components 105
Figure 105. Installing the cooling fan cage board
Next steps
1. Connect cables to the fan board.
2. Replace the following components:
a. Cooling fan cage assembly
b. Air shroud
3. Follow the procedure listed in After working inside your system.
System board
This is a service technician replaceable part only.
Removing the system board
Prerequisites
CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted
to create a recovery key during program or System Setup. Be sure to create and safely store this recovery key.
If you replace this system board, you must supply the recovery key when you restart your system or program
before you can access the encrypted data on your drives.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the following components:
a. Air shroud
b. Cooling fan cage assembly
c. Expansion cards
d. IDSDM module (if installed)
e. Internal USB key (if installed)
f. Processor and heat sink module
g. Memory modules
h. OCP (if installed)
106 Installing and removing system components
i. OCP shroud
j. Disconnect all cables from the system board.
CAUTION: Take care not to damage the system identification button while removing the system board
from the system.
Steps
1. Using the system board holder and plunger, slide the system board toward the front of the chassis.
2. By using holder and plunger that is located on system board and lift the system board out of the chassis, leaning at an angle.
Figure 106. Removing the system board
Next steps
Replace the system board.
Installing the system board
Prerequisites
NOTE: Before replacing the system board, replace the old iDRAC MAC address label in the Information tag with the iDRAC
MAC address label of the replacement system board
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. If you are replacing the system board, remove all the components that are listed in the removing the system board section.
Steps
1. Unpack the new system board assembly.
CAUTION: Do not lift the system board by holding a memory module, processor, or other components.
Installing and removing system components 107
CAUTION: Take care not to damage the system identification button while placing the system board into the
chassis.
2. Using the system board holder and plunger , lower the system board leaning at an angle into the system.
3. Slide the system board towards the rear of the chassis until the connectors are firmly seated in the slots.
Figure 107. Installing the system board
Next steps
1. Replace the following components:
a. Trusted Platform Module (TPM)
NOTE: The TPM Module must be replaced only while installing new system board.
b. IDSDM module (if removed)
c. Internal USB key (if removed)
d. Expansion cards
e. Cooling fan cage assembly
f. Processor and heat sink module
g. Memory modules
h. OCP (if removed)
i. OCP shroud
j. Air shroud
2. Reconnect all cables to the system board.
NOTE: Ensure that the cables inside the system are routed along the chassis wall and secured using the cable securing
bracket.
3. Ensure that you perform the following steps:
a. Use the Easy Restore feature to restore the Service Tag. See the Restoring the system by using the Easy Restore
feature section.
b. If the service tag is not backed up in the backup flash device, enter the system service tag manually. See the Manually
update the Service Tag by using System Setup section.
c. Update the BIOS and iDRAC versions.
Re-enable the Trusted Platform Module (TPM). See the Upgrading the Trusted Platform Module section.
108 Installing and removing system components
4. If you are not using Easy restore, import your new or existing iDRAC Enterprise license. For more information, see the
Integrated Dell Remote Access Controller User's Guide available at https://www.dell.com/idracmanuals .
5. Follow the procedure listed in After working inside your system.
Restoring the system using Easy Restore
The Easy Restore feature enables you to restore your service tag, license, UEFI configuration, and the system configuration data
after replacing the system board. All data is backed up in a backup flash device automatically. If BIOS detects a new system
board, and the service tag in the backup flash device, BIOS prompts the user to restore the backup information.
About this task
Below is a list of options/steps available:
●Restore the service tag, license, and diagnostics information, press Y
●Navigate to the Lifecycle Controller based restore options, press N
●Restore data from a previously created Hardware Server Profile, press F10
NOTE: When the restore process is complete, BIOS prompts to restore the system configuration data.
●Restore data from a previously created Hardware Server Profile, press F10
●To restore the system configuration data, press Y
●To use the default configuration settings, press N
●NOTE: After the restore process is complete, system reboots.
Trusted Platform Module
This is a service technician replaceable part only.
Upgrading the Trusted Platform Module
Removing the TPM
Prerequisites
NOTE:
●Ensure the operating system is compatible with the TPM version you are installing.
●Ensure that you download and install the latest BIOS firmware on your system.
●Ensure that the BIOS is configured to enable UEFI boot mode.
CAUTION: The TPM plug-in module is cryptographically bound to that particular system board after it is
installed. When the system is powered on, any attempt to remove an installed TPM plug-in module breaks the
cryptographic binding, and the removed TPM cannot be installed on another system board. Ensure any keys you
have stored on the TPM have been securely transferred.
Steps
1. Locate the TPM connector on the system board. For more information, see System board connectors.
2. Press to hold the module down and remove the screw using the security Torx 8-bit shipped with the TPM module.
3. Slide the TPM module out from its connector.
4. Push the plastic rivet away from the TPM connector and rotate it 90° counterclockwise to release it from the system board.
5. Pull the plastic rivet out of its slot on the system board.
Installing and removing system components 109
Installing the TPM
Steps
1. To install the TPM, align the edge connectors on the TPM with the slot on the TPM connector.
2. Insert the TPM into the TPM connector such that the plastic rivet aligns with the slot on the system board.
3. Press the plastic rivet until the rivet snaps into place.
4. Replace the screw that secures the TPM to the system board.
Figure 108. Installing the TPM
Initializing TPM for users
Steps
1. Initialize the TPM.
For more information, see Initializing the TPM for users.
2. The TPM Status changes to Enabled, Activated.
Initializing the TPM 1.2 for users
Steps
1. While booting your system, press F2 to enter System Setup.
2. On the System Setup Main Menu screen, click System BIOS > System Security Settings.
3. From the TPM Security option, select On with Preboot Measurements.
4. From the TPM Command option, select Activate.
5. Save the settings.
6. Restart your system.
Initializing the TPM 2.0 for users
Steps
1. While booting your system, press F2 to enter System Setup.
2. On the System Setup Main Menu screen, click System BIOS > System Security Settings.
3. From the TPM Security option, select On.
4. Save the settings.
5. Restart your system.
110 Installing and removing system components
Control panel
This is a service technician replaceable part only.
Removing the left control panel
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
5. Remove the cooling fan cage assembly.
Steps
1. Disconnect the control panel cable from the system board connector.
NOTE: Observe the routing of the cable as you remove it from the system.
2. Using the Phillips #1 screwdriver, remove the screws that secure the cable cover and left control panel assembly to the
system.
3. Remove the cable cover away the system.
4. Holding the left control panel assembly , remove the control panel along with the cable from the system.
Figure 109. Removing the left control panel
Next steps
Replace the left control panel.
Installing and removing system components 111
Installing the left control panel
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
Steps
1. Align and slide the left control panel assembly in the slot on the system.
2. Route the left control panel cable through the side wall of the system.
3. Align and slide the left control panel cable cover in the slot on the system.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
4. Connect the left control panel cable to the connector on the system board .
5. Using the Phillips #1 screwdriver, tighten the screws to secures the left control panel and the cable cover to the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 110. Installing the left control panel
Next steps
1. Install the cooling fan cage assembly.
2. Install the drive backplane cover.
3. Install the air shroud.
4. Follow the procedure listed in the After working inside your system.
Removing the right control panel
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
112 Installing and removing system components
4. Remove the drive backplane cover.
5. Remove the cooling fan cage assembly.
Steps
1. Disconnect the right control panel cable and the VGA cable from the connectors on the system board.
NOTE: Observe the routing of the cable as you remove it from the system.
2. Remove the cable from cable clip.
3. Using the Phillips #1 screwdriver, remove the screws that secures the right control panel and cable cover to the system.
4. Holding the right control panel assembly, remove the control panel along with the cable from the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 111. Removing the right control panel
Next steps
Replace the right control panel.
Installing the right control panel
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
5. Remove the cooling fan cage assembly.
Installing and removing system components 113
Steps
1. Align and slide the right control panel assembly in the slot on the system.
2. Route the right control panel cable through the side wall of the system.
3. Align and slide the right control panel cable cover in the slot on the system.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
4. Connect the right control panel cable and VGA cable to the connectors on the system board.
5. Using the Phillips #1 screwdriver, tighten the screws that secures the right control panel and the cable cover to the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 112. Installing the right control panel
Next steps
1. Install the cooling fan cage assembly.
2. Install the drive backplane cover.
3. Install the air shroud.
4. Follow the procedure listed in the After working inside your system.
114 Installing and removing system components
Optional optical drive
This is a service technician replaceable part only.
Removing the optical disk drive
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
5. Disconnect the power and signal cables from the optical disk drive (ODD) and observe the cable routing.
Steps
Press the blue latch to disengage the ODD from the system and slide out the ODD.
Figure 113. Removing the ODD
Next steps
Replace the ODD.
Installing the optical disk drive
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
Installing and removing system components 115
Steps
Slide the optical disk drive (ODD), until the latch is seated firmly into the system slot.
Figure 114. Installing the ODD
Next steps
1. Connect the power and signal cables to the ODD and system board connector. Route the cables though the side wall
bracket.
2. Install the drive backplane cover.
3. Install the air shroud.
4. Follow the procedure listed in After working inside your system.
116 Installing and removing system components
Jumpers and connectors
This section provides essential and specific information about jumpers and switches. It also describes the connectors on the
various boards in the system. Jumpers on the system board help to disable the system and reset the passwords. To install
components and cables correctly, you must be able to identify the connectors on the system board.
Topics:
•System board connectors
•System board jumper settings
•Disabling a forgotten password
System board connectors
Figure 115. System board jumpers and connectors
Table 27. System board jumpers and connectors
Item Connector Description
1. SYS_ID System ID Connector
6
Jumpers and connectors 117
Table 27. System board jumpers and connectors (continued)
Item Connector Description
2. x16 (CPU2) PCIe slot 5 ( Processor 2)
3. Coin cell battery Coin cell battery
4. OCP 3.0 x16 OCP NIC 3.0 Connector
5. J_TPM TPM Connector
6. IDSDM/Internal USB connector IDSDM/Internal USB connector
7. REAR_SERIAL Serial Port Connector
8. x4 (PCH) x4 PCIe slot 2 (PCH) / BOSS signal
connector (PCH)
9. FRONT_VIDEO Front VGA
10. PWRD_EN / NVRAM_CLR PWRD_EN / NVRAM_CLR (Jumpers)
11. x16 (CPU1) x16 PCIe slot 1 (Processor 1)
12. SL9_PCH_SA1 SATA Connector S9 (PCH)
13. ODD Optical disk drive connector
14. RGT_CP Right Control Panel
15. A3, A7, A1, A5 DIMMs for processor 1 Channels A, B, C,
D
16. CPU 1 SL10_PCH_PA5 Processor 1
17. A6, A2, A8, A4 DIMMs for processor 1 Channels E, F, G,
H
18. SL3_CPU1_PB2 PCIe cable connector 3 (Processor 1)
19. B6, B2, B8, B4 DIMMs for processor 2 Channels E, F, G,
H
20. SYS_PWR2 System Power Connector 2
21. CPU 2 Processor 2
22. B3, B7, B1, B5 DIMM for processor 2 channels A, B, C,
D
23. LFT_CP Left Control Panel
24. FAN_SIG1 Fan Signal 1
25. FAN_SIG2 Fan Signal 2
26. PIB_SIG1 PIB Signal 1
27. PIB_SIG2 PIB Signal 2
28. INTRUSION Intrusion Switch Connector
29. SYS_PWR1 System Power Connector 1
30. x16 (CPU2) PCIe slot 6 ( Processor 2)
System board jumper settings
For information about resetting the password jumper to disable a password, see the Disabling a forgotten password section.
118 Jumpers and connectors
Table 28. System board jumper settings
Jumper Setting Description
PWRD_EN The BIOS password feature is enabled.
The BIOS password feature is disabled. The BIOS password is
now disabled and you are not allowed to set a new password.
NVRAM_CLR The BIOS configuration settings are retained at system boot.
The BIOS configuration settings are cleared at system boot.
CAUTION: You should be cautious when changing the BIOS settings. The BIOS interface is designed for
advanced users. Any changes in the setting might prevent your system from starting correctly and may even
result in data loss.
Disabling a forgotten password
The software security features of the system include a system password and a setup password. The password jumper enables or
disables password features and clears any password(s) currently in use.
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by
your warranty. Read and follow the safety instructions that are shipped with your product.
Steps
1. Power off the system and all attached peripherals. Disconnect the system from the electrical outlet, and disconnect the
peripherals.
2. Remove the system cover.
3. Move the jumper on the system board from pins 2 and 4 to pins 4 and 6.
4. Replace the system cover.
NOTE: The existing passwords are not disabled (erased) until the system boots with the jumper on pins 4 and 6.
However, before you assign a new system and/or setup password, you must move the jumper back to pins 2 and 4.
NOTE: If you assign a new system and/or setup password with the jumper on pins 4 and 6, the system disables the new
password(s) the next time it boots.
5. Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.
6. Power off the system.
7. Remove the system cover.
8. Move the jumper on the system board from pins 4 and 6 to pins 2 and 4.
9. Replace the system cover.
10. Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.
11. Assign a new system and/or setup password.
Jumpers and connectors 119
System diagnostics and indicator codes
This section describes the diagnostic indicators on the system front panel that displays the system status during system startup.
Topics:
•Status LED indicators
•System health and system ID indicator codes
•iDRAC Quick Sync 2 indicator codes
•iDRAC Direct LED indicator codes
•LCD panel
•NIC indicator codes
•Power supply unit indicator codes
•Drive indicator codes
•Using system diagnostics
Status LED indicators
NOTE: The indicators display solid amber if any error occurs.
Figure 116. Status LED indicators
Table 29. Status LED indicators and descriptions
Icon Description Condition Corrective action
Drive indicator The indicator turns solid amber if
there is a drive error.
●Check the System Event Log to determine if the
drive has an error.
●Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
●If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
●A cooling fan has been removed or has failed.
●System cover, air shrouds, or back filler bracket
has been removed.
●Ambient temperature is too high.
●External airflow is obstructed.
If the problem persists, see the Getting help section.
7
120 System diagnostics and indicator codes
Table 29. Status LED indicators and descriptions (continued)
Icon Description Condition Corrective action
Electrical
indicator
The indicator turns solid amber
if the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or voltage
regulator).
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see the
Getting help section.
Memory indicator The indicator turns solid amber if a
memory error occurs.
Check the System Event Log or system messages
for the location of the failed memory. Reseat the
memory module.
If the problem persists, see the
Getting help section.
PCIe indicator The indicator turns solid amber if a
PCIe card experiences an error.
Restart the system. Update any required drivers for
the PCIe card. Reinstall the card.
If the problem persists, see the
Getting help section.
NOTE: For more information about the
supported PCIe cards, see the Expansion card
installation guidelines section.
System health and system ID indicator codes
The system health and system ID indicator is located on the left control panel of the system.
Figure 117. System health and system ID indicator
Table 30. System health and system ID indicator codes
System health and system ID
indicator code
Condition
Solid blue Indicates that the system is powered on, is healthy, and system ID mode is not active.
Press the system health and system ID button to switch to system ID mode.
Blinking blue Indicates that the system ID mode is active. Press the system health and system ID
button to switch to system health mode.
Solid amber Indicates that the system is in fail-safe mode. If the problem persists, see the Getting
help section.
Blinking amber Indicates that the system is experiencing a fault. Check the System Event Log
for specific error messages. For information about the event and error messages
generated by the system firmware and agents that monitor system components, go
to qrl.dell.com > Look Up > Error Code, type the error code, and then click Look it
up.
System diagnostics and indicator codes 121
iDRAC Quick Sync 2 indicator codes
iDRAC Quick Sync 2 module (optional) is located on the left control panel of the system.
Table 31. iDRAC Quick Sync 2 indicators and descriptions
iDRAC Quick Sync 2 indicator
code
Condition Corrective action
Off (default state) Indicates that the iDRAC Quick Sync 2
feature is powered off. Press the iDRAC
Quick Sync 2 button to power on the
iDRAC Quick Sync 2 feature.
If the LED fails to power on, reseat the left
control panel flex cable and check. If the problem
persists, see the Getting help section.
Solid white Indicates that iDRAC Quick Sync 2 is
ready to communicate. Press the iDRAC
Quick Sync 2 button to power off.
If the LED fails to power off, restart the system.
If the problem persists, see the Getting help
section.
Blinks white rapidly Indicates data transfer activity. If the indicator continues to blink indefinitely, see
the
Getting help section.
Blinks white slowly Indicates that firmware update is in
progress. If the indicator continues to blink indefinitely, see
the
Getting help section.
Blinks white five times rapidly
and then powers off
Indicates that the iDRAC Quick Sync 2
feature is disabled.
Check if iDRAC Quick Sync 2 feature is
configured to be disabled by iDRAC. If
the problem persists, see the Getting help
section. www.dell.com/poweredgemanuals or Dell
OpenManage Server Administrator User’s Guide
at https://www.dell.com/openmanagemanuals.
Solid amber Indicates that the system is in fail-safe
mode.
Restart the system. If the problem persists, see
the Getting help section.
Blinking amber Indicates that the iDRAC Quick Sync 2
hardware is not responding properly.
Restart the system. If the problem persists, see
the Getting help section.
iDRAC Direct LED indicator codes
The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRAC
subsystem.
You can configure iDRAC Direct by using a USB to micro USB (type AB) cable, which you can connect to your laptop or
tablet. Cable length should not exceed 3 feet (0.91 meters). Performance could be affected by cable quality. The following table
describes iDRAC Direct activity when the iDRAC Direct port is active:
Table 32. iDRAC Direct LED indicator codes
iDRAC Direct LED
indicator code
Condition
Solid green for two
seconds
Indicates that the laptop or tablet is connected.
Blinking green (on for
two seconds and off for
two seconds)
Indicates that the laptop or tablet connected is recognized.
122 System diagnostics and indicator codes
Table 32. iDRAC Direct LED indicator codes (continued)
iDRAC Direct LED
indicator code
Condition
LED Indicator off Indicates that the laptop or tablet is unplugged.
LCD panel
The LCD panel provides system information, status, and error messages to indicate if the system is functioning correctly or
requires attention. The LCD panel is used to configure or view the iDRAC IP address of the system. For information about the
event and error messages generated by the system firmware and agents that monitor system components, go to qrl.dell.com >
Look Up > Error Code, type the error code, and then click Look it up..
The LCD panel is available only on the optional front bezel. The optional front bezel is hot pluggable.
The status and conditions of the LCD panel are outlined here:
●The LCD backlight is white during normal operating conditions.
●If there is an issue, the LCD backlight turns amber and displays an error code followed by descriptive text.
NOTE: If the system is connected to a power source and an error is detected, the LCD turns amber regardless of
whether the system is powered on or off.
●When the system powers off and there are no errors, the LCD enters the standby mode after five minutes of inactivity.
Press any button on the LCD to power it on.
●If the LCD panel stops responding, remove the bezel and reinstall it.
If the problem persists, see Getting help.
●The LCD backlight remains off if LCD messaging is powered off using the iDRAC utility, the LCD panel, or other tools.
Figure 118. LCD panel features
Table 33. LCD panel features
Item Button or
display
Description
1 Left Moves the cursor back in one-step increments.
2 Select Selects the menu item highlighted by the cursor.
3 Right Moves the cursor forward in one-step increments.
During message scrolling:
●Press and hold the right button to increase scrolling speed.
●Release the button to stop.
NOTE: The display stops scrolling when the button is released. After 45 seconds of inactivity,
the display starts scrolling.
4 LCD display Displays the system information, status, and error messages or iDRAC IP address.
System diagnostics and indicator codes 123
Viewing Home screen
The Home screen displays user-configurable information about the system. This screen is displayed during normal system
operation when there are no status messages or errors. When the system turns off and there are no errors, LCD enters the
standby mode after five minutes of inactivity. Press any button on the LCD to turn it on.
Steps
1. To view the Home screen, press one of the three navigation buttons (Select, Left, or Right).
2. To navigate to the Home screen from another menu, complete the following steps:
a. Press and hold the navigation button till the up arrow is displayed.
b. Navigate to the Home icon using the up arrow .
c. Select the Home icon.
d. On the Home screen, press the Select button to enter the main menu.
Setup menu
NOTE: When you select an option in the Setup menu, you must confirm the option before proceeding to the next action.
Table 34. Setup menu
Option Description
iDRAC Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available fields
are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domain
addresses. Two separate DNS entries are available.
Set error Select SEL to view LCD error messages in a format that matches the IPMI description in the SEL. This
enables you to match an LCD message with an SEL entry. Select Simple to view LCD error messages in
a simplified user-friendly description. For information about the event and error messages generated by
the system firmware and agents that monitor system components, go to qrl.dell.com > Look Up > Error
Code, type the error code, and then click Look it up..
Set home Select the default information to be displayed on the Home screen. See View menu section for the options
and option items that can be set as the default on the Home screen.
View menu
NOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next action.
Table 35. View menu
Option Description
iDRAC IP Displays the IPv4 or IPv6 addresses for iDRAC9. Addresses include DNS (Primary and
Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).
MAC Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Name Displays the name of the Host, Model, or User String for the system.
Number Displays the Asset tag or the Service tag for the system.
Power Displays the power output of the system in BTU/hr or Watts. The display format can be
configured in the Set home submenu of the Setup menu.
Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format can
be configured in the Set home submenu of the Setup menu.
124 System diagnostics and indicator codes
NIC indicator codes
Each NIC on the back of the system has indicators that provide information about the activity and link status. The activity LED
indicator indicates if data is flowing through the NIC, and the link LED indicator indicates the speed of the connected network.
Figure 119. NIC indicator codes
1. Link LED indicator
2. Activity LED indicator
Table 36. NIC indicator codes
NIC indicator codes Condition
Link and activity indicators are off. Indicates that the NIC is not connected to the network.
Link indicator is green, and activity indicator is blinking
green.
Indicates that the NIC is connected to a valid network at its maximum
port speed, and data is being sent or received.
Link indicator is amber, and activity indicator is blinking
green.
Indicates that the NIC is connected to a valid network at less than its
maximum port speed, and data is being sent or received.
Link indicator is green, and activity indicator is off. Indicates that the NIC is connected to a valid network at its maximum
port speed, and data is not being sent or received.
Link indicator is amber, and activity indicator is off. Indicates that the NIC is connected to a valid network at less than its
maximum port speed, and data is not being sent or received.
Link indicator is blinking green, and activity is off. Indicates that the NIC identity is enabled through the NIC
configuration utility.
Power supply unit indicator codes
AC and DC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator. The indicator shows if
power is present or if a power fault has occurred.
Figure 120. AC PSU status indicator
1. AC PSU handle
2. Socket
3. Release latch
System diagnostics and indicator codes 125
Table 37. AC PSU status indicator codes
Power indicator codes Condition
Green Indicates that a valid power source is connected to the PSU
and the PSU is operational.
Blinking amber Indicates an issue with the PSU.
Not powered on Indicates that the power is not connected to the PSU.
Blinking green Indicates that the firmware of the PSU is being updated.
CAUTION: Do not disconnect the power cord or
unplug the PSU when updating firmware. If firmware
update is interrupted, the PSUs will not function.
Blinking green and powers off When hot-plugging a PSU, it blinks green five times at a rate
of 4 Hz and powers off. This indicates a PSU mismatch due to
efficiency, feature set, health status, or supported voltage.
CAUTION: If two PSUs are installed, both the PSUs
must have the same type of label; for example,
Extended Power Performance (EPP) label. Mixing
PSUs from previous generations of PowerEdge
servers is not supported, even if the PSUs have the
same power rating. This results in a PSU mismatch
condition or failure to power on the system.
CAUTION: If two PSUs are used, they must be of
the same type and have the same maximum output
power.
CAUTION: When correcting a PSU mismatch, replace
the PSU with the blinking indicator. Swapping the
PSU to make a matched pair can result in an error
condition and an unexpected system shutdown. To
change from a high output configuration to a low
output configuration or vice versa, you must power
off the system.
CAUTION: AC PSUs support both 240 V and 120 V
input voltages with the exception of Titanium PSUs,
which support only 240 V. When two identical PSUs
receive different input voltages, they can output
different wattages, and trigger a mismatch.
Table 38. DC PSU status indicator codes
Power indicator codes Condition
Green Indicates that a valid power source is connected to the PSU,
and the PSU is operational.
Blinking amber Indicates an issue with the PSU.
Not powered on Indicates that the power is not connected to the PSU.
Blinking green When hot-plugging a PSU, it blinks green five times at a rate
of 4 Hz and powers off. This indicates a PSU mismatch due to
efficiency, feature set, health status, or supported voltage.
CAUTION: If two PSUs are installed, both the PSUs
must have the same type of label; for example,
Extended Power Performance (EPP) label. Mixing
PSUs from previous generations of PowerEdge
servers is not supported, even if the PSUs have the
126 System diagnostics and indicator codes
Table 38. DC PSU status indicator codes (continued)
Power indicator codes Condition
same power rating. This results in a PSU mismatch
condition, or failure to power on the system.
CAUTION: If two PSUs are used, they must be of
the same type and have the same maximum output
power.
CAUTION: When correcting a PSU mismatch, replace
the PSU with the blinking indicator. Swapping the
PSU to make a matched pair can result in an error
condition and an unexpected system shutdown. To
change from a High Output configuration to a Low
Output configuration or conversely, you must power
off the system.
CAUTION: Combining AC and DC PSUs is not
supported.
Drive indicator codes
The LEDs on the drive carrier indicate the state of each drive. Each drive carrier has two LEDs: an activity LED (green) and a
status LED (bicolor, green/amber). The activity LED blinks whenever the drive is accessed.
Figure 121. Drive indicators on the drive and the mid drive tray backplane
1. Drive activity LED indicator
2. Drive status LED indicator
3. Drive capacity label
NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on.
NOTE: Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.
Table 39. Drive indicator codes
Drive status indicator code Condition
Blinks green twice per second Indicates that the drive is being identified or preparing for removal.
Off Indicates that the drive is ready for removal.
System diagnostics and indicator codes 127
Table 39. Drive indicator codes (continued)
Drive status indicator code Condition
NOTE: The drive status indicator remains off until all drives are
initialized after the system is powered on. Drives are not ready
for removal during this time.
Blinks green, amber, and then powers off Indicates that there is an unexpected drive failure.
Blinks amber four times per second Indicates that the drive has failed.
Blinks green slowly Indicates that the drive is rebuilding.
Solid green Indicates that the drive is online.
Blinks green for three seconds, amber for three seconds,
and then powers off after six seconds
Indicates that the rebuild has stopped.
Using system diagnostics
If you experience an issue with the system, run the system diagnostics before contacting Dell for technical assistance. The
purpose of running system diagnostics is to test the system hardware without using additional equipment or risking data loss.
If you are unable to fix the issue yourself, service and support personnel can use the diagnostics results to help you solve the
issue.
Dell Embedded System Diagnostics
NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA)
diagnostics.
The Embedded System Diagnostics provide a set of options for particular device groups or devices allowing you to:
●Run tests automatically or in an interactive mode
●Repeat tests
●Display or save test results
●Run thorough tests to introduce additional test options to provide extra information about the failed device(s)
●View status messages that inform you if tests are completed successfully
●View error messages that inform you of issues encountered during testing
Running the Embedded System Diagnostics from the Dell Lifecycle
Controller
Steps
1. When the system is booting, press F10.
2. Select Hardware Diagnostics → Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics
start executing the tests on all the detected devices.
Running the Embedded System Diagnostics from Boot Manager
Run the Embedded System Diagnostics (ePSA) if your system does not boot.
Steps
1. When the system is booting, press F11.
2. Use the up arrow and down arrow keys to select System Utilities > Launch Diagnostics.
3. Alternatively, when the system is booting, press F10, select Hardware Diagnostics > Run Hardware Diagnostics.
128 System diagnostics and indicator codes
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics
starts executing the tests on all the detected devices.
System diagnostic controls
Table 40. System diagnostic controls
Menu Description
Configuration Displays the configuration and status information of all
detected devices.
Results Displays the results of all tests that are run.
System health Provides the current overview of the system performance.
Event log Displays a time-stamped log of the results of all tests run on
the system. This is displayed if at least one event description
is recorded.
System diagnostics and indicator codes 129
Getting help
Topics:
•Recycling or End-of-Life service information
•Contacting Dell Technologies
•Accessing system information by using QRL
•Receiving automated support with SupportAssist
Recycling or End-of-Life service information
Take back and recycling services are offered for this product in certain countries. If you want to dispose of system components,
visit www.dell.com/recyclingworldwide and select the relevant country.
Contacting Dell Technologies
Dell provides online and telephone based support and service options. If you do not have an active internet connection, you can
find Dell contact information on your purchase invoice, packing slip, bill or Dell product catalog. The availability of services varies
depending on the country and product, and some services may not be available in your area. To contact Dell for sales, technical
assistance, or customer service issues follow these steps:
Steps
1. Go to www.dell.com/support/home.
2. Select your country from the drop-down menu on the lower right corner of the page.
3. For customized support:
a. Enter the system Service Tag in the Enter a Service Tag, Serial Number, Service Request, Model, or Keyword
field.
b. Click Search.
The support page that lists the various support categories is displayed.
4. For general support:
a. Select your product category.
b. Select your product segment.
c. Select your product.
The support page that lists the various support categories is displayed.
5. For contact details of Dell Global Technical Support:
a. Click Contact Technical Support.
b. The Contact Technical Support page is displayed with details to call, chat, or e-mail the Dell Global Technical Support
team.
Accessing system information by using QRL
You can use the Quick Resource Locator (QRL) located on the information tag in the front of the R550 system, to access
information about Dell EMC PowerEdge R550. There is also another QRL for accessing product information located on the back
of the system cover.
Prerequisites
Ensure that your smartphone or tablet has a QR code scanner installed.
8
130 Getting help
The QRL includes the following information about your system:
●How-to videos
●Reference materials, including the Installation and Service Manual, LCD diagnostics, and mechanical overview
●The system service tag to quickly access the specific hardware configuration and warranty information
●A direct link to Dell to contact technical assistance and sales teams
Steps
1. Go to www.dell.com/qrl, and navigate to your specific product or
2. Use your smart phone or tablet to scan the model-specific Quick Resource (QR) code on your system or in the Quick
Resource Locator section.
Quick Resource Locator for PowerEdge R550 system
Figure 122. Quick Resource Locator for PowerEdge R550 system
Receiving automated support with SupportAssist
Dell EMC SupportAssist is an optional Dell EMC Services offering that automates technical support for your Dell EMC server,
storage, and networking devices. By installing and setting up a SupportAssist application in your IT environment, you can receive
the following benefits:
●Automated issue detection — SupportAssist monitors your Dell EMC devices and automatically detects hardware issues,
both proactively and predictively.
●Automated case creation — When an issue is detected, SupportAssist automatically opens a support case with Dell EMC
Technical Support.
●Automated diagnostic collection — SupportAssist automatically collects system state information from your devices and
uploads it securely to Dell EMC. This information is used by Dell EMC Technical Support to troubleshoot the issue.
●Proactive contact — A Dell EMC Technical Support agent contacts you about the support case and helps you resolve the
issue.
The available benefits vary depending on the Dell EMC Service entitlement purchased for your device. For more information
about SupportAssist, go to www.dell.com/supportassist.
Getting help 131
Documentation resources
This section provides information about the documentation resources for your system.
To view the document that is listed in the documentation resources table:
●From the Dell EMC support site:
1. Click the documentation link that is provided in the Location column in the table.
2. Click the required product or product version.
NOTE: To locate the model number, see the front of your system.
3. On the Product Support page, click Documentation.
●Using search engines:
○Type the name and version of the document in the search box.
Table 41. Additional documentation resources for your system
Task Document Location
Setting up your system For more information about installing and
securing the system into a rack, see the
Rail Installation Guide included with your rail
solution.
For information about setting up your system,
see the Getting Started Guide
document that is shipped with your system.
www.dell.com/poweredgemanuals
Configuring your system For information about the iDRAC features,
configuring and logging in to iDRAC, and
managing your system remotely, see the
Integrated Dell Remote Access Controller
User's Guide.
For information about understanding Remote
Access Controller Admin (RACADM)
subcommands and supported RACADM
interfaces, see the RACADM CLI Guide for
iDRAC.
For information about Redfish and its protocol,
supported schema, and Redfish
Eventing implemented in iDRAC, see the
Redfish API Guide.
For information about iDRAC property
database group and object descriptions, see
the Attribute Registry Guide.
For information about Intel QuickAssist
Technology, see the Integrated Dell Remote
Access Controller User's Guide.
www.dell.com/poweredgemanuals
For information about earlier versions of the
iDRAC documents.
To identify the version of iDRAC available on
your system, on the iDRAC web interface,
click ? > About.
www.dell.com/idracmanuals
9
132 Documentation resources
Table 41. Additional documentation resources for your system (continued)
Task Document Location
For information about installing the
operating system, see the operating system
documentation.
www.dell.com/operatingsystemmanuals
For information about updating drivers and
firmware, see the Methods to download
firmware and drivers section in this document.
www.dell.com/support/drivers
Managing your system For information about systems management
software offered by Dell, see the Dell
OpenManage Systems Management Overview
Guide.
www.dell.com/poweredgemanuals
For information about setting up, using,
and troubleshooting OpenManage, see the
Dell OpenManage Server Administrator User’s
Guide.
www.dell.com/openmanagemanuals >
OpenManage Server Administrator
For information about installing and using Dell
SupportAssist, see the Dell EMC SupportAssist
Enterprise User’s Guide.
https://www.dell.com/serviceabilitytools
For information about partner programs
enterprise systems management, see the
OpenManage Connections Enterprise Systems
Management documents.
www.dell.com/openmanagemanuals
Working with the Dell
PowerEdge RAID controllers
For information about understanding the
features of the Dell PowerEdge RAID
controllers (PERC), Software RAID controllers,
or BOSS card and deploying the cards, see the
Storage controller documentation.
www.dell.com/storagecontrollermanuals
Understanding event and
error messages
For information about the event and error
messages generated by the system firmware
and agents that monitor system components,
go to qrl.dell.com > Look Up > Error Code,
type the error code, and then click Look it up.
www.dell.com/qrl
Troubleshooting your
system
For information about identifying and
troubleshooting the PowerEdge server issues,
see the Server Troubleshooting Guide.
www.dell.com/poweredgemanuals
Documentation resources 133