Table of Contents
- Dell EMC PowerEdge R740 Installation and Service Manual
- PowerEdge R740 system overview
- Documentation resources
- Technical specifications
- System dimensions
- Chassis weight
- Processor specifications
- Supported operating systems
- PSU specifications
- System battery specifications
- Expansion bus specifications
- Memory specifications
- Storage controller specifications
- Drive specifications
- Ports and connectors specifications
- Video specifications
- Environmental specifications
- Initial system setup and configuration
- Pre-operating system management applications
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Optional front bezel
- System cover
- Backplane cover
- Inside the system
- Air shroud
- Cooling fan assembly
- Cooling fans
- Intrusion switch
- NVDIMM-N battery
- Drives
- Drive guidelines
- Removing a drive blank
- Installing a drive blank
- Removing a drive carrier
- Installing a drive carrier
- Removing a 2.5 inch drive from the 3.5 inch drive adapter
- Installing a 2.5 inch drive into the 3.5 inch drive adapter
- Removing a 3.5 inch adapter from a 3.5 inch drive carrier
- Installing a 3.5 inch adapter into a 3.5 inch drive carrier
- Removing the drive from the drive carrier
- Installing a drive into the drive carrier
- System memory
- Processors and heat sinks
- Expansion cards and expansion card risers
- Expansion card installation guidelines
- Opening and closing the PCIe card holder latch
- Removing expansion card from the expansion card riser
- Installing expansion card into the expansion card riser
- Removing riser 2 and 3 blank
- Installing riser 2 and 3 blank
- Removing riser 3 blank
- Installing riser 3 blank
- Removing expansion card riser 1
- Installing expansion card riser 1
- Removing expansion card riser 2
- Installing expansion card riser 2
- Removing expansion card riser 3
- Installing expansion card riser 3
- GPU card installation guidelines
- Removing a GPU
- Installing a GPU
- M.2 SSD module
- Optional IDSDM or vFlash module
- Network daughter card
- Integrated storage controller card
- Backplane
- Cable routing
- System battery
- USB 3.0 module
- Optional internal USB memory key
- Optional optical drive
- Power supply units
- System board
- Trusted Platform Module
- Control panel
- Using system diagnostics
- Jumpers and connectors
- Getting help
DELL R740 User Manual
Displayed below is the user manual for R740 by DELL which is a product in the Servers category. This manual has pages.
Related Manuals
Dell EMC PowerEdge R740
Installation and Service Manual
Regulatory Model: E38S Series
Regulatory Type: E38S001
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks
may be trademarks of their respective owners.
2019 - 06
Rev. A09
Contents
1 PowerEdge R740 system overview.................................................................................................................8
Supported congurations..................................................................................................................................................8
Front view of the system.................................................................................................................................................10
Left control panel view...............................................................................................................................................12
Right control panel view............................................................................................................................................ 15
Back view of the system................................................................................................................................................. 16
NIC indicator codes.................................................................................................................................................... 18
Power supply unit indicator codes............................................................................................................................18
Drive indicator codes........................................................................................................................................................21
LCD panel..........................................................................................................................................................................22
Viewing Home screen................................................................................................................................................23
Setup menu.................................................................................................................................................................23
View menu.................................................................................................................................................................. 23
Locating the Service Tag of your system......................................................................................................................24
System information label.................................................................................................................................................24
PowerEdge R740 – Front system information label.............................................................................................. 24
PowerEdge R740 – Service information.................................................................................................................25
2 Documentation resources............................................................................................................................ 29
3 Technical specications................................................................................................................................31
System dimensions........................................................................................................................................................... 31
Chassis weight................................................................................................................................................................. 32
Processor specications................................................................................................................................................. 33
Supported operating systems.........................................................................................................................................33
PSU specications...........................................................................................................................................................33
System battery specications........................................................................................................................................ 34
Expansion bus specications..........................................................................................................................................34
Memory specications.................................................................................................................................................... 36
Storage controller specications....................................................................................................................................37
Drive specications..........................................................................................................................................................37
Drives...........................................................................................................................................................................37
Optical drive................................................................................................................................................................37
Ports and connectors specications..............................................................................................................................37
USB ports....................................................................................................................................................................37
NIC ports.....................................................................................................................................................................38
VGA ports................................................................................................................................................................... 38
Serial connector......................................................................................................................................................... 38
Internal Dual SD Module or vFlash card..................................................................................................................38
Video specications.........................................................................................................................................................38
Environmental specications..........................................................................................................................................39
Standard operating temperature..............................................................................................................................40
Contents 3
Expanded operating temperature............................................................................................................................ 40
Particulate and gaseous contamination specications..........................................................................................42
4 Initial system setup and conguration.......................................................................................................... 44
Setting up your system................................................................................................................................................... 44
iDRAC conguration........................................................................................................................................................ 44
Options to set up iDRAC IP address........................................................................................................................44
Log in to iDRAC..........................................................................................................................................................45
Options to install the operating system.........................................................................................................................45
Methods to download rmware and drivers...........................................................................................................45
Downloading drivers and rmware.......................................................................................................................... 46
5 Pre-operating system management applications..........................................................................................47
Options to manage the pre-operating system applications........................................................................................ 47
System Setup................................................................................................................................................................... 47
Viewing System Setup...............................................................................................................................................47
System Setup details.................................................................................................................................................48
System BIOS.............................................................................................................................................................. 48
iDRAC Settings utility................................................................................................................................................ 69
Device Settings.......................................................................................................................................................... 70
Dell Lifecycle Controller...................................................................................................................................................70
Embedded system management..............................................................................................................................70
Boot Manager...................................................................................................................................................................70
Viewing Boot Manager..............................................................................................................................................70
Boot Manager main menu......................................................................................................................................... 71
One-shot UEFI boot menu........................................................................................................................................ 71
System Utilities............................................................................................................................................................71
PXE boot............................................................................................................................................................................71
6 Installing and removing system components................................................................................................ 72
Safety instructions........................................................................................................................................................... 72
Before working inside your system................................................................................................................................ 72
After working inside your system...................................................................................................................................72
Recommended tools........................................................................................................................................................ 73
Optional front bezel..........................................................................................................................................................73
Front bezel details...................................................................................................................................................... 73
Removing the front bezel..........................................................................................................................................73
Installing the front bezel............................................................................................................................................ 74
System cover....................................................................................................................................................................75
Removing the system cover.....................................................................................................................................75
Installing the system cover....................................................................................................................................... 76
Backplane cover............................................................................................................................................................... 77
Removing the backplane cover................................................................................................................................ 77
Installing the backplane cover.................................................................................................................................. 78
Inside the system............................................................................................................................................................. 79
Air shroud...........................................................................................................................................................................81
4Contents
Removing the air shroud............................................................................................................................................81
Installing the air shroud..............................................................................................................................................82
Cooling fan assembly.......................................................................................................................................................83
Removing the cooling fan assembly........................................................................................................................ 83
Installing the cooling fan assembly...........................................................................................................................84
Cooling fans......................................................................................................................................................................85
Cooling fan details......................................................................................................................................................85
Removing a cooling fan.............................................................................................................................................86
Installing a cooling fan............................................................................................................................................... 86
Intrusion switch................................................................................................................................................................ 87
Removing an intrusion switch...................................................................................................................................87
Installing an intrusion switch.....................................................................................................................................88
NVDIMM-N battery.........................................................................................................................................................89
NVDIMM-N battery details.......................................................................................................................................89
Removing the NVDIMM-N battery from the air shroud.......................................................................................89
Installing NVDIMM-N battery into air shroud.........................................................................................................90
Removing NVDIMM-N battery from mid drive tray............................................................................................... 91
Installing NVDIMM-N battery into mid drive tray...................................................................................................92
Removing NVDIMM-N battery from the bracket.................................................................................................. 93
Installing NVDIMM-N battery into the bracket......................................................................................................94
Drives................................................................................................................................................................................ 95
Drive guidelines.......................................................................................................................................................... 95
Removing a drive blank............................................................................................................................................. 95
Installing a drive blank................................................................................................................................................96
Removing a drive carrier........................................................................................................................................... 96
Installing a drive carrier..............................................................................................................................................97
Removing a 2.5 inch drive from the 3.5 inch drive adapter..................................................................................98
Installing a 2.5 inch drive into the 3.5 inch drive adapter......................................................................................99
Removing a 3.5 inch adapter from a 3.5 inch drive carrier................................................................................. 100
Installing a 3.5 inch adapter into a 3.5 inch drive carrier...................................................................................... 101
Removing the drive from the drive carrier............................................................................................................102
Installing a drive into the drive carrier....................................................................................................................103
System memory..............................................................................................................................................................104
System memory guidelines......................................................................................................................................104
General memory module installation guidelines.................................................................................................... 106
NVDIMM-N memory module installation guidelines ............................................................................................107
DCPMM installation guidelines ..............................................................................................................................108
Mode-specic guidelines.........................................................................................................................................109
Removing a memory module................................................................................................................................... 112
Installing a memory module......................................................................................................................................113
Processors and heat sinks..............................................................................................................................................114
Removing a processor and heat sink module........................................................................................................ 114
Removing the processor from the processor and heat sink module..................................................................115
Installing the processor into a processor and heat sink module..........................................................................116
Installing a processor and heat sink module...........................................................................................................118
Contents 5
Expansion cards and expansion card risers..................................................................................................................119
Expansion card installation guidelines.....................................................................................................................119
Opening and closing the PCIe card holder latch...................................................................................................123
Removing expansion card from the expansion card riser....................................................................................125
Installing expansion card into the expansion card riser........................................................................................128
Removing riser 2 and 3 blank..................................................................................................................................130
Installing riser 2 and 3 blank.....................................................................................................................................131
Removing riser 3 blank.............................................................................................................................................132
Installing riser 3 blank...............................................................................................................................................133
Removing expansion card riser 1.............................................................................................................................134
Installing expansion card riser 1...............................................................................................................................135
Removing expansion card riser 2............................................................................................................................136
Installing expansion card riser 2.............................................................................................................................. 137
Removing expansion card riser 3............................................................................................................................139
Installing expansion card riser 3.............................................................................................................................. 139
GPU card installation guidelines..............................................................................................................................140
Removing a GPU.......................................................................................................................................................141
Installing a GPU.........................................................................................................................................................143
M.2 SSD module.............................................................................................................................................................149
Removing the M.2 SSD module............................................................................................................................. 149
Installing the M.2 SSD module................................................................................................................................150
Optional IDSDM or vFlash module................................................................................................................................ 151
Removing the MicroSD and vFlash card................................................................................................................151
Installing the MicroSD and vFlash card..................................................................................................................152
Removing the optional IDSDM or vFlash module.................................................................................................153
Installing optional IDSDM or vFlash card............................................................................................................... 154
Network daughter card................................................................................................................................................. 155
Removing the network daughter card...................................................................................................................155
Installing the network daughter card..................................................................................................................... 156
Integrated storage controller card................................................................................................................................ 157
Removing integrated storage controller card........................................................................................................157
Installing integrated storage controller card..........................................................................................................158
Backplane........................................................................................................................................................................160
Backplane details......................................................................................................................................................160
Removing the backplane..........................................................................................................................................161
Installing the backplane ...........................................................................................................................................162
Cable routing...................................................................................................................................................................163
System battery............................................................................................................................................................... 169
Replacing the system battery................................................................................................................................. 169
USB 3.0 module.............................................................................................................................................................. 170
USB 3.0 module details............................................................................................................................................ 170
Removing USB 3.0 module.......................................................................................................................................171
Installing USB 3.0 module.........................................................................................................................................171
Optional internal USB memory key...............................................................................................................................172
Optional internal USB memory key details.............................................................................................................172
6Contents
Replacing the optional internal USB memory key.................................................................................................173
Optional optical drive......................................................................................................................................................173
Removing the optional optical drive....................................................................................................................... 173
Installing the optional optical drive..........................................................................................................................174
Power supply units......................................................................................................................................................... 175
Power supply unit details.........................................................................................................................................175
Hot spare feature......................................................................................................................................................176
Removing a power supply unit blank......................................................................................................................176
Installing a power supply unit blank........................................................................................................................ 177
Removing a power supply unit................................................................................................................................ 177
Installing a power supply unit.................................................................................................................................. 178
Wiring instructions for a DC power supply unit.................................................................................................... 179
System board...................................................................................................................................................................181
Removing system board........................................................................................................................................... 181
Installing system board.............................................................................................................................................182
Trusted Platform Module...............................................................................................................................................184
Upgrading the Trusted Platform Module...............................................................................................................185
Initializing TPM for BitLocker users........................................................................................................................186
Initializing the TPM 1.2 for TXT users....................................................................................................................186
Initializing the TPM 2.0 for TXT users................................................................................................................... 186
Control panel................................................................................................................................................................... 187
Control panel details................................................................................................................................................. 187
Removing the left control panel..............................................................................................................................187
Installing the left control panel................................................................................................................................188
Removing the right control panel...........................................................................................................................189
Installing the right control panel............................................................................................................................. 190
7 Using system diagnostics........................................................................................................................... 192
Dell Embedded System Diagnostics.............................................................................................................................192
Running the Embedded System Diagnostics from Boot Manager.....................................................................192
Running the Embedded System Diagnostics from the Dell Lifecycle Controller..............................................192
System diagnostic controls..................................................................................................................................... 193
8 Jumpers and connectors ........................................................................................................................... 194
System board jumpers and connectors.......................................................................................................................195
System board jumper settings.......................................................................................................................................197
Disabling forgotten password........................................................................................................................................197
9 Getting help............................................................................................................................................... 198
Contacting Dell EMC..................................................................................................................................................... 198
Documentation feedback.............................................................................................................................................. 198
Accessing system information by using QRL..............................................................................................................198
Quick Resource Locator for PowerEdge R740 and R740xd systems................................................................199
Receiving automated support with SupportAssist ....................................................................................................199
Recycling or End-of-Life service information..............................................................................................................199
Contents 7
PowerEdge R740 system overview
The PowerEdge R740 is a 2U rack server that supports up to:
• Two Intel Xeon Scalable Processors
• 24 DIMM slots
• Two AC or DC power supply units
• 16 SAS, SATA, Nearline SAS hard drives or SSDs. For more information about supported drives, see the Technical specications section.
NOTE: All instances of SAS, SATA hard drives, NVMe and SSDs are referred to as drives in this document, unless specied
otherwise.
Topics:
• Supported congurations
• Front view of the system
• Back view of the system
• Drive indicator codes
• LCD panel
• Locating the Service Tag of your system
• System information label
Supported congurations
The PowerEdge R740 system supports the following congurations:
1
8 PowerEdge R740 system overview
Figure 1. Supported congurations
PowerEdge R740 system overview 9
Front view of the system
The front view displays the features available on the front of the system.
Figure 2. Front view of 16 x 2.5 inch drive system
Table 1. Features available on the front of 16 x 2.5 inch drive system
Item Ports, panels and slots Icon Description
1 Left control panel N/A Contains system health and system ID, status LED and optional
iDRAC Quick Sync 2 (wireless).
2 Drive slots N/A Enable you to install drives that are supported on your system. For
more information about drives, see Technical specications section.
3 Optical drive (optional) N/A Enables you to retrieve and store data on optical discs such as
compact discs (CD) and digital versatile discs (DVD). For more
information, see Technical specications section.
4 USB 3.0 port (optional) The USB ports are 9-pin, 3.0-compliant. These ports enable you to
connect USB devices to the system.
5 Right control panel N/A Contains the power button, VGA port, iDRAC Direct micro USB port,
and two USB 2.0 ports.
6 Information tag N/A The Information tag is a slide-out label panel that contains system
information such as Service Tag, NIC, MAC address, and so on. If you
have opted for the secure default access to iDRAC, the Information
tag also contains the iDRAC secure default password.
10 PowerEdge R740 system overview
Figure 3. Front view of 8 x 2.5-inch drive system
Table 2. Features available on the front of 8 x 2.5-inch drive system
Item Ports, panels and slots Icon Description
1 Left control panel N/A Contains system health and system ID, status LED and optional
iDRAC Quick Sync 2 (wireless).
2 Drive slots N/A Enable you to install drives that are supported on your system. For
more information about drives, see Technical specications section.
3 Optical drive (optional) N/A Enables you to retrieve and store data on optical discs such as
compact discs (CD) and digital versatile discs (DVD). For more
information, see Technical specications section.
4 USB 3.0 port (optional) The USB ports are 9-pin, 3.0-compliant. These ports enable you to
connect USB devices to the system.
5 Right control panel N/A Contains the power button, VGA port, iDRAC Direct micro USB port,
and two USB 2.0 ports.
6 Information tag N/A The Information tag is a slide-out label panel that contains system
information such as Service Tag, NIC, MAC address, and so on. If you
have opted for the secure default access to iDRAC, the Information
tag also contains the iDRAC secure default password.
Figure 4. Front view of 8 x 3.5 inch drive system
PowerEdge R740 system overview 11
Table 3. Features available on the front of 8 x 3.5 inch drive system
Item Ports, panels and slots Icon Description
1 Left control panel N/A Contains system health and system ID, status LED and optional
iDRAC Quick Sync 2 (wireless).
2 Drive slots N/A Enable you to install drives that are supported on your system. For
more information about drives, see Technical specications section.
3 USB 3.0 port (optional) The USB ports are 9-pin, 3.0-compliant. These ports enable you to
connect USB devices to the system.
4 Optical drive (optional) N/A Enables you to retrieve and store data on optical discs such as
compact discs (CD) and digital versatile discs (DVD). For more
information, see Technical specications section.
5 Right control panel N/A Contains the power button, VGA port, iDRAC Direct micro USB port,
and two USB 2.0 ports.
6 Information tag N/A The Information tag is a slide-out label panel that contains system
information such as Service Tag, NIC, MAC address, and so on. If you
have opted for the secure default access to iDRAC, the Information
tag also contains the iDRAC secure default password.
Left control panel view
Figure 5. Left control panel with optional iDRAC Quick Sync 2.0 indicator
Table 4. Left control panel
Item Indicator, button, or
connector
Icon Description
1 Status LED indicators N/A Indicate the status of the system. For more information, see the
Status LED indicators section.
2 System health and system
ID indicator
Indicates the system health. For more information, see the System
health and system ID indicator codes section.
3 iDRAC Quick Sync 2
wireless indicator (optional)
Indicates if the iDRAC Quick Sync 2 wireless option is activated. The
Quick Sync 2 feature allows management of the system using mobile
devices. This feature aggregates hardware/rmware inventory and
various system level diagnostic/error information that can be used in
troubleshooting the system. You can access system inventory, Dell
Lifecycle Controller logs or system logs, system health status, and
12 PowerEdge R740 system overview
Item Indicator, button, or
connector
Icon Description
also congure iDRAC, BIOS, and networking parameters. You can also
launch the virtual Keyboard, Video, and Mouse (KVM) viewer and
virtual Kernel based Virtual Machine (KVM), on a supported mobile
device. For more information, see the Integrated Dell Remote Access
Controller User's Guide at www.dell.com/poweredgemanuals.
Status LED indicators
NOTE: The indicators display solid amber if any error occurs.
Table 5. Status LED indicators and descriptions
Icon Description Condition Corrective action
Drive
indicator
The indicator turns solid amber if
there is a drive error. • Check the System Event Log to determine if the drive has an error.
• Run the appropriate Online Diagnostics test. Restart the system and
run embedded diagnostics (ePSA).
• If the drives are congured in a RAID array, restart the system, and
enter the host adapter conguration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
• A cooling fan has been removed or has failed.
• System cover, air shroud, memory module blank, or back ller bracket is
removed.
• Ambient temperature is too high.
• External airow is obstructed.
If the problem persists, see Getting help.
Electrical
indicator
The indicator turns solid amber if
the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or voltage
regulator).
Check the System Event Log or system messages for the specic issue. If
it is due to a problem with the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see Getting help.
Memory
indicator
The indicator turns solid amber if a
memory error occurs.
Check the System Event Log or system messages for the location of the
failed memory. Reseat the memory module.
If the problem persists, see Getting help.
PCIe
indicator
The indicator turns solid amber if a
PCIe card experiences an error.
Restart the system. Update any required drivers for the PCIe card. Reinstall
the card.
If the problem persists, see Getting help.
NOTE: For more information about the supported PCIe cards, see
Expansion card installation guidelines.
PowerEdge R740 system overview 13
System health and system ID indicator codes
The system health and system ID indicator is located on the left control panel of your system.
Figure 6. System health and system ID indicators
Table 6. System health and system ID indicator codes
System health and system ID indicator code Condition
Solid blue Indicates that the system is turned on, system is healthy, and system
ID mode is not active. Press the system health and system ID button
to switch to system ID mode.
Blinking blue Indicates that the system ID mode is active. Press the system health
and system ID button to switch to system health mode.
Solid amber Indicates that the system is in fail-safe mode.
If the problem persists, see the Getting help section.
Blinking amber Indicates that the system is experiencing a fault. Check the System
Event Log or the LCD panel, if available on the bezel, for specic error
messages.
For more information about error messages, see the Event and Error
Message Reference Guide for 14th Generation Dell EMC PowerEdge
Servers at www.dell.com/qrl.
iDRAC Quick Sync 2 indicator codes
iDRAC Quick Sync 2 module (optional) is located on the left control panel of your system.
Figure 7. iDRAC Quick Sync 2 indicators
Table 7. iDRAC Quick Sync 2 indicators and descriptions
iDRAC Quick Sync 2 indicator
code
Condition Corrective action
O (default state) Indicates that the iDRAC Quick Sync 2
feature is turned o. Press the iDRAC Quick
If the LED fails to turn on, reseat the left control panel
ex cable and check. If the problem persists, see
Getting help.
14 PowerEdge R740 system overview
iDRAC Quick Sync 2 indicator
code
Condition Corrective action
Sync 2 button to turn on the iDRAC Quick
Sync 2 feature.
Solid white Indicates that iDRAC Quick Sync 2 is ready
to communicate. Press the iDRAC Quick
Sync 2 button to turn o.
If the LED fails to turn o, restart the system. If the
problem persists, see Getting help.
Blinks white rapidly Indicates data transfer activity. If the indicator continues to blink indenitely, see
Getting help.
Blinks white slowly Indicates that rmware update is in
progress.
If the indicator continues to blink indenitely, see
Getting help.
Blinks white ve times rapidly and
then turns o
Indicates that the iDRAC Quick Sync 2
feature is disabled.
Check if iDRAC Quick Sync 2 feature is congured to
be disabled by iDRAC. If the problem persists, see the
Getting help section. For more information, see
Integrated Dell Remote Access Controller User's
Guide at www.dell.com/poweredgemanuals or Dell
OpenManage Server Administrator User’s Guide at
www.dell.com/openmanagemanuals > OpenManage
Server Administrator.
Solid amber Indicates that the system is in fail-safe
mode.
Restart the system. If the problem persists, see
Getting help.
Blinking amber Indicates that the iDRAC Quick Sync 2
hardware is not responding properly.
Restart the system. If the problem persists, see
Getting help.
Right control panel view
Figure 8. Right control panel view
Table 8. Right control panel features
Item Indicator, button, or
connector
Icon Description
1 Power button Indicates if the system is turned on or o. Press the power button to
manually turn on or o the system.
PowerEdge R740 system overview 15
Item Indicator, button, or
connector
Icon Description
NOTE: Press the power button to gracefully shut down an
ACPI-compliant operating system.
2 USB port (2) The USB ports are 4-pin, 2.0-compliant. These ports enable you to
connect USB devices to the system.
3 iDRAC Direct port The iDRAC Direct port is micro USB 2.0-compliant. This port enables
you to access the iDRAC Direct features. For more information, see
the iDRAC User’s Guide at www.dell.com/poweredgemanuals.
4 iDRAC Direct LED N/A The iDRAC Direct LED indicator lights up to indicate that the iDRAC
Direct port is connected. For more information, see the iDRAC Direct
LED indicator codes section.
5 VGA port Enables you to connect a display device to the system. For more
information, see the Technical specication section.
iDRAC Direct LED indicator codes
The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRAC subsystem.
iDRAC Direct LED indicator is located below the iDRAC Direct port on the right control panel.
You can congure iDRAC Direct by using a USB to micro USB (type AB) cable, which you can connect to your laptop or tablet. The
following table describes iDRAC Direct activity when the iDRAC Direct port is active:
Table 9. iDRAC Direct LED indicator codes
iDRAC Direct LED
indicator code
Condition
Solid green for two seconds Indicates that the laptop or tablet is connected.
Flashing green (on for two
seconds and o for two
seconds)
Indicates that the laptop or tablet connected is recognized.
Turns o Indicates that the laptop or tablet is unplugged.
Back view of the system
The back view of the system provides access to the features available on the back of the server.
16 PowerEdge R740 system overview
Figure 9. Back view of three riser system
Table 10. Features available on the back view
Item Panels, ports and slots Icon Description
1 Full-height PCIe expansion
card slot (3)
N/A The PCIe expansion card slot (riser 1) connects up to three full-height
PCIe expansion cards to the system. For more information, see the
Expansion card installation guidelines section.
2 Half-height PCIe expansion
card slot
N/A The PCIe expansion card slot (riser 2) connects one half-height PCIe
expansion cards to the system. For more information, see Expansion card
installation guidelines section.
3 Rear handle N/A The rear handle can be removed to enable any external cabling of PCIe
cards that are installed in the PCIe expansion card slot 6.
4 Full-height PCIe expansion
card slot (2)
N/A The PCIe expansion card slot (riser 2) connects up to two full-height
PCIe expansion cards to the system. For more information, see
Expansion card installation guidelines section.
5 Full-height PCIe expansion
card slot (2)
N/A The PCIe expansion card slot (riser 3) connects up to two full-height
PCIe expansion cards to the system. For more information, see
Expansion card installation guidelines section.
6 Power supply unit (2) N/A For more information, see Technical specications section.
7 NIC ports The NIC ports that are integrated on the network daughter card (NDC)
provide network connectivity. For more information about the supported
congurations, see Technical specications section.
8 USB port (2) The USB ports are 9-pin and 3.0-compliant. These ports enable you to
connect USB devices to the system.
9 VGA port Enables you to connect a display device to the system. For more
information, see the Technical specications section.
10 Serial port Enables you to connect a serial device to the system. For more
information, see the Technical specications section.
11 iDRAC9 dedicated port Enables you to remotely access iDRAC. For more information, see the
iDRAC User’s Guide at www.dell.com/poweredgemanuals.
12 System identication button The System Identication (ID) button is available on the front and back of
the systems. Press the button to identify a system in a rack by turning on
PowerEdge R740 system overview 17
Item Panels, ports and slots Icon Description
the system ID button. You can also use the system ID button to reset
iDRAC and to access BIOS using the step through mode.
NIC indicator codes
Each NIC on the back of the system has indicators that provide information about the activity and link status. The activity LED indicator
indicates if data is owing through the NIC, and the link LED indicator indicates the speed of the connected network.
Figure 10. NIC indicator codes
1 link LED indicator 2 activity LED indicator
Table 11. NIC indicator codes
Status Condition
Link and activity indicators are o The NIC is not connected to the network.
Link indicator is green and activity indicator is blinking green The NIC is connected to a valid network at its maximum port speed and
data is being sent or received.
Link indicator is amber and activity indicator is blinking
green
The NIC is connected to a valid network at less than its maximum port
speed and data is being sent or received.
Link indicator is green and activity indicator is o The NIC is connected to a valid network at its maximum port speed and
data is not being sent or received.
Link indicator is amber and activity indicator is o The NIC is connected to a valid network at less than its maximum port
speed and data is not being sent or received.
Link indicator is blinking green and activity is o NIC identify is enabled through the NIC conguration utility.
Power supply unit indicator codes
AC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator.
The DC PSUs have an LED that serves as an indicator.
The indicator shows whether power is present or if a power fault has occurred.
18 PowerEdge R740 system overview
Figure 11. AC PSU status indicator
1 AC PSU status indicator/handle
Table 12. AC PSU status indicator codes
Power indicator codes Condition
Green A valid power source is connected to the PSU and the PSU is operational.
Blinking amber Indicates a problem with the PSU.
Not illuminated Power is not connected to the PSU.
Blinking green When the rmware of the PSU is being updated, the PSU handle blinks green.
CAUTION: Do not disconnect the power cord or unplug the PSU when updating rmware. If
rmware update is interrupted, the PSUs do not function.
Blinking green and turns o When hot-plugging a PSU, the PSU handle blinks green ve times at a rate of 4 Hz and turns o. This
indicates a PSU mismatch with respect to eciency, feature set, health status, or supported voltage.
CAUTION: If two PSUs are installed, both the PSUs must have the same type of label; for
example, Extended Power Performance (EPP) label. Mixing PSUs from previous generations of
PowerEdge servers is not supported, even if the PSUs have the same power rating. This results
in a PSU mismatch condition or failure to turn the system on.
CAUTION: When correcting a PSU mismatch, replace only the PSU with the blinking indicator.
Swapping the PSU to make a matched pair can result in an error condition and unexpected
system shutdown. To change from a high output conguration to a low output conguration or
vice versa, you must turn o the system.
CAUTION: AC PSUs support both 240 V and 120 V input voltages with the exception of Titanium
PSUs, which support only 240 V. When two identical PSUs receive dierent input voltages, they
can output dierent wattages, and trigger a mismatch.
CAUTION: If two PSUs are used, they must be of the same type and have the same maximum
output power.
CAUTION: Combining AC and DC PSUs is not supported and triggers a mismatch.
PowerEdge R740 system overview 19
Figure 12. DC PSU status indicator
1 DC PSU status indicator
Table 13. DC PSU status indicator codes
Power indicator codes Condition
Green A valid power source is connected to the PSU and the PSU is operational.
Blinking amber Indicates a problem with the PSU.
Not illuminated Power is not connected to the PSU.
Blinking green When hot-plugging a PSU, the PSU indicator blinks green. This indicates that there is a PSU mismatch
with respect to eciency, feature set, health status, or supported voltage.
CAUTION: If two PSUs are installed, both the PSUs must have the same type of label; for
example, Extended Power Performance (EPP) label. Mixing PSUs from previous generations
of PowerEdge servers is not supported, even if the PSUs have the same power rating. This
results in a PSU mismatch condition or failure to turn the system on.
CAUTION: When correcting a PSU mismatch, replace only the PSU with the blinking
indicator. Swapping the PSU to make a matched pair can result in an error condition and
unexpected system shutdown. To change from a High Output conguration to a Low Output
conguration or vice versa, you must turn o the system.
CAUTION: If two PSUs are used, they must be of the same type and have the same
maximum output power.
CAUTION: Combining AC and DC PSUs is not supported and triggers a mismatch.
20 PowerEdge R740 system overview
Drive indicator codes
Each drive carrier has an activity LED indicator and a status LED indicator. The indicators provide information about the current status of
the drive. The activity LED indicator indicates whether the drive is currently in use or not. The status LED indicator indicates the power
condition of the drive.
Figure 13. Drive indicators
1Drive activity LED indicator 2 Drive status LED indicator
3 Drive
NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not turn on.
Table 14. Drive indicator codes
Drive status indicator code Condition
Flashes green twice per second Identifying drive or preparing for removal.
O Drive ready for removal.
NOTE: The drive status indicator remains o until all drives are
initialized after the system is turned on. Drives are not ready
for removal during this time.
Flashes green, amber, and then turns o Predicted drive failure.
Flashes amber four times per second Drive failed.
Flashes green slowly Drive rebuilding.
Solid green Drive online.
Flashes green for three seconds, amber for three seconds, and
then turns o after six seconds
Rebuild stopped.
PowerEdge R740 system overview 21
LCD panel
The LCD panel provides system information, status, and error messages to indicate if the system is functioning correctly or requires
attention. The LCD panel can also be used to congure or view the system’s iDRAC IP address. For information about the event and error
messages generated by the system rmware and agents that monitor system components, see the Error Code Lookup page at qrl.dell.com.
The LCD panel is available only on the optional front bezel. The optional front bezel is hot pluggable.
The statuses and conditions of the LCD panel are outlined here:
• The LCD backlight is white during normal operating conditions.
• When the system needs attention, the LCD backlight turns amber, and displays an error code followed by descriptive text.
NOTE: If the system is connected to a power source and an error is detected, the LCD turns amber regardless of whether
the system is turned on or o.
• When the system turns o and there are no errors, LCD enters the standby mode after ve minutes of inactivity. Press any button on
the LCD to turn it on.
• If the LCD panel stops responding, remove the bezel and reinstall it.
If the problem persists, see Getting help.
• The LCD backlight remains o if LCD messaging is turned o using the iDRAC utility, the LCD panel, or other tools.
Figure 14. LCD panel features
Table 15. LCD panel features
Item Button or display Description
1 Left Moves the cursor back in one-step increments.
2 Select Selects the menu item highlighted by the cursor.
3 Right Moves the cursor forward in one-step increments.
During message scrolling:
• Press and hold the right button to increase scrolling speed.
• Release the button to stop.
NOTE: The display stops scrolling when the button is released. After 45 seconds of inactivity, the
display starts scrolling.
4 LCD display Displays system information, status, and error messages or iDRAC IP address.
22 PowerEdge R740 system overview
Viewing Home screen
The Home screen displays user-congurable information about the system. This screen is displayed during normal system operation when
there are no status messages or errors. When the system turns o and there are no errors, LCD enters the standby mode after ve
minutes of inactivity. Press any button on the LCD to turn it on.
1 To view the Home screen, press one of the three navigation buttons (Select, Left, or Right).
2 To navigate to the Home screen from another menu, complete the following steps:
a Press and hold the navigation button till the up arrow is displayed.
bNavigate to the Home icon using the up arrow .
c Select the Home icon.
d On the Home screen, press the Select button to enter the main menu.
Setup menu
NOTE: When you select an option in the Setup menu, you must conrm the option before proceeding to the next action.
Option Description
iDRAC Select DHCP or Static IP to congure the network mode. If Static IP is selected, the available elds are IP,
Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domain addresses. Two
separate DNS entries are available.
Set error Select SEL to view LCD error messages in a format that matches the IPMI description in the SEL. This enables you
to match an LCD message with an SEL entry.
Select Simple to view LCD error messages in a simplied user-friendly description.
For more information about error messages, see the Event and Error Message Reference Guide for 14th
Generation Dell EMC PowerEdge Servers at www.dell.com/qrl.
Set home Select the default information to be displayed on the Home screen. See View menu section for the options and
option items that can be set as the default on the Home screen.
View menu
NOTE: When you select an option in the View menu, you must conrm the option before proceeding to the next action.
Option Description
iDRAC IP Displays the IPv4 or IPv6 addresses for iDRAC9. Addresses include DNS (Primary and Secondary), Gateway, IP,
and Subnet (IPv6 does not have Subnet).
MAC Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Name Displays the name of the Host, Model, or User String for the system.
Number Displays the Asset tag or the Service tag for the system.
Power Displays the power output of the system in BTU/hr or Watts. The display format can be congured in the Set
home submenu of the Setup menu.
PowerEdge R740 system overview 23
Option Description
Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format can be congured in the Set
home submenu of the Setup menu.
Locating the Service Tag of your system
You can identify your system using the unique Express Service Code and Service Tag. Pull out the information tag in front of the system to
view the Express Service Code and Service Tag. Alternatively, the information may be on a sticker on the chassis of the system. The mini
Enterprise Service Tag (EST) is found on the back of the system. This information is used by Dell to route support calls to the appropriate
personnel.
Figure 15. Locating Service Tag of your system
1information tag (top view) 2 information tag (back view)
3 OpenManage Mobile (OMM) label 4 iDRAC MAC address and iDRAC secure password label
5 Service Tag
System information label
PowerEdge R740 – Front system information label
LED behavior, express service tag, hard drives conguration and layout
24 PowerEdge R740 system overview
Figure 16. LED behavior
Figure 17. 2.5 inch hard drives conguration and layout
Figure 18. 3.5 inch hard drives conguration and layout
PowerEdge R740 – Service information
System touchpoint, electrical overview, mechanical overview and rear view congurations
PowerEdge R740 system overview 25
Figure 19. Service Information
26 PowerEdge R740 system overview
Figure 20. Jumper setting and memory information
Figure 21. system task
PowerEdge R740 system overview 27
Figure 22. NVDIMM battery and mid-tray hard drives
28 PowerEdge R740 system overview
Documentation resources
This section provides information about the documentation resources for your system.
To view the document that is listed in the documentation resources table:
• From the Dell EMC support site:
a Click the documentation link that is provided in the Location column in the table.
b Click the required product or product version.
NOTE: To locate the product name and model, see the front of your system.
c On the Product Support page, click Manuals & documents.
• Using search engines:
– Type the name and version of the document in the search box.
Table 16. Additional documentation resources for your system
Task Document Location
Setting up your system For more information about installing and securing
the system into a rack, see the Rail Installation
Guide included with your rack solution.
For information about setting up your system, see
the Getting Started Guide document that is
shipped with your system.
www.dell.com/poweredgemanuals
Conguring your system For information about the iDRAC features,
conguring and logging in to iDRAC, and managing
your system remotely, see the Integrated Dell
Remote Access Controller User's Guide.
For information about understanding Remote
Access Controller Admin (RACADM)
subcommands and supported RACADM interfaces,
see the RACADM CLI Guide for iDRAC.
For information about Redsh and its protocol,
supported schema, and Redsh Eventing
implemented in iDRAC, see the Redsh API Guide.
For information about iDRAC property database
group and object descriptions, see the Attribute
Registry Guide.
www.dell.com/poweredgemanuals
For information about earlier versions of the iDRAC
documents.
To identify the version of iDRAC available on your
system, on the iDRAC web interface, click ? >
About.
www.dell.com/idracmanuals
For information about installing the operating
system, see the operating system documentation.
www.dell.com/operatingsystemmanuals
2
Documentation resources 29
Task Document Location
For information about updating drivers and
rmware, see the Methods to download rmware
and drivers section in this document.
www.dell.com/support/drivers
Managing your system For information about systems management
software oered by Dell, see the Dell OpenManage
Systems Management Overview Guide.
www.dell.com/poweredgemanuals
For information about setting up, using, and
troubleshooting OpenManage, see the Dell
OpenManage Server Administrator User’s Guide.
www.dell.com/openmanagemanuals >
OpenManage Server Administrator
For information about installing, using, and
troubleshooting Dell OpenManage Essentials, see
the Dell OpenManage Essentials User’s Guide.
www.dell.com/openmanagemanuals >
OpenManage Essentials
For information about installing and using Dell
SupportAssist, see the Dell EMC SupportAssist
Enterprise User’s Guide.
www.dell.com/serviceabilitytools
For information about partner programs enterprise
systems management, see the OpenManage
Connections Enterprise Systems Management
documents.
www.dell.com/openmanagemanuals
Working with the Dell
PowerEdge RAID controllers
For information about understanding the features
of the Dell PowerEdge RAID controllers (PERC),
Software RAID controllers, or BOSS card and
deploying the cards, see the Storage controller
documentation.
www.dell.com/storagecontrollermanuals
Understanding event and error
messages
For information about the event and error
messages generated by the system rmware and
agents that monitor system components, see the
Error Code Lookup.
www.dell.com/qrl
Troubleshooting your system For information about identifying and
troubleshooting the PowerEdge server issues, see
the Server Troubleshooting Guide.
www.dell.com/poweredgemanuals
30 Documentation resources
Technical specications
The technical and environmental specications of your system are outlined in this section.
Topics:
• System dimensions
• Chassis weight
• Processor specications
• Supported operating systems
• PSU specications
• System battery specications
• Expansion bus specications
• Memory specications
• Storage controller specications
• Drive specications
• Ports and connectors specications
• Video specications
• Environmental specications
System dimensions
This section describes the physical dimensions of the system.
3
Technical specications 31
Figure 23. System dimensions of PowerEdge R740 system
Table 17. Dimensions
System Xa Xb Y Za (with
bezel)
Za (without
bezel)
Zb Zc
PowerEdge R740 482.0 mm
(18.98
inches)
434.0 mm
(17.09 inches)
86.8 mm
(3.42 inches)
35.84 mm
(1.41 inches)
22.0 mm
(0.87 inches)
678.8 mm
(26.72
inches)
715.5 mm
(28.17 inches)
Chassis weight
Table 18. Chassis weight
System Maximum weight (with all drives/SSDs)
2.5 inch drive systems 26.3 kg (57.98 lb)
3.5 inch drive systems 28.6 kg (63.05 lb)
32 Technical specications
Processor specications
The PowerEdge R740 system supports up to two Intel Xeon Processor Scalable Family processors, up to 28 cores per processor.
Supported operating systems
The PowerEdge R740 supports the following operating systems:
Canonical Ubuntu LTS
Citrix XenServer
Microsoft Windows Server with Hyper-V
Red Hat Enterprise Linux
SUSE Linux Enterprise Server
VMware ESXi
For more information on the specic versions and additions, visit www.dell.com/support/home/Drivers/SupportedOS/poweredge-r740.
PSU specications
The PowerEdge R740 system supports up to two AC or DC power supply units (PSUs).
Table 19. PSU specications
PSU Class Heat dissipation
(maximum)
Frequency Voltage High line
200v240 V
Low line
100– 140 V
DC Current
495 W AC Platinum 1908 BTU/hr 50/60 Hz 100–240 V AC,
autoranging
495 W 495 W 6.5 A–3 A
750 W AC Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC,
autoranging
750 W 750 W 10 A–5 A
750 W AC Titanium 2843 BTU/hr 50/60 Hz 200–240 V AC,
autoranging
750 W 5 A
750 W
Mixed
Mode
HVDC (for
China only)
Platinum 2891 BTU/hr 50/60 Hz 100–240 V AC,
autoranging
750 W 750 W 10 A–5 A
N/A 2891 BTU/hr N/A 240 V DC,
autoranging
750W 4.5 A
1100 W AC Platinum 4100 BTU/hr 50/60 Hz 100–240 V AC,
autoranging
1100 W 1050 W 12 A–6.5 A
1100 W DC N/A 4416 BTU/hr N/A –(48–60) V DC,
autoranging
1100 W 32 A
1100 W
Mixed
Mode
HVDC (for
Platinum 4100 BTU/hr 50/60 Hz 100–240 V AC,
autoranging
1100 W 1050 W 12 A–6.5 A
N/A 4100 BTU/hr N/A 200–380 V DC,
autoranging
1100 W 6.4 A–3.2 A
Technical specications 33
PSU Class Heat dissipation
(maximum)
Frequency Voltage High line
200v240 V
Low line
100– 140 V
DC Current
China and
Japan only)
1600 W AC Platinum 6000 BTU/hr 50/60 Hz 100–240 V AC,
autoranging
1600 W 800 W 10 A
2000 W AC Platinum 7500 BTU/hr 50/60 Hz 100–240 V AC,
autoranging
2000 W 1000 W 11.5 A
2400 W AC Platinum 9000 BTU/hr 50/60 Hz 100–240 V AC,
autoranging
2400 W 1400 W 16 A
NOTE: Heat dissipation is calculated using the PSU wattage rating.
NOTE: This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 240 V.
NOTE: PSUs rated for 1100 W Mixed Mode HVDC or 1100 W AC and higher require high-line voltage (200–240 V AC) to supply
their rated capacity.
System battery specications
The PowerEdge R740 system supports CR 2032 3.0-V lithium coin cell system battery.
Expansion bus specications
The PowerEdge R740 system supports up to eight PCI express (PCIe) generation 3 expansion cards that can be installed on the system
board using expansion card risers. The following table provides detailed information about the expansion card riser specications:
Table 20. Expansion card riser congurations
Expansion card
riser
PCIe slots on the
riser
Height Length Link
Riser 1A Slot 1 Full Height Full Length x16
Slot 3 Full Height Half Length x16
Riser 1B Slot 1 Full Height Full Length x8
Slot 2 Full Height Full Length x8
Slot 3 Full Height Half Length x8
Riser 1D Slot 1 Full Height Full Length x16
Slot 2 Full Height Full Length x8
Slot 3 Full Height Half Length x8
Riser 2A Slot 4 Full Height Full Length x16
Slot 5 Full Height Full Length x8
Slot 6 Low Prole Half Length x8
Riser 2B Slot 4 Low Prole Half Length x8
Riser 2C Slot 4 Low Prole Half Length x16
Riser 3A Slot 7 Full Height Full Length x8
34 Technical specications
Expansion card
riser
PCIe slots on the
riser
Height Length Link
Slot 8 Full Height Full Length x16
Table 21. Expansion card riser specications
Riser
conguration
and supported
risers
Slot description PCIe slots on
riser 1 (Height
and length)
Processor
connection
PCIe slots on riser
2 (Height and
length)
Processor
connection
PCIe slots on
riser 3 (Height
and length)
Processor
connection
Riser
conguration 0
(No riser)
No PCIe slots
(only rear
storage)
N/A N/A N/A N/A N/A N/A
Riser
conguration 1
(1B+2B)
Four x8 slots
Slot 1: x8 full-
height, full length
Processor 1
Slot 4: x8 low
prole, half length Processor 1 N/A N/A
Slot 2: x8 full-
height, full length
Processor 1
Slot 3: x8 full-
height, half length
Processor 1
Riser
conguration 2
(1B+2C)
Three x8 and
one x16 slots
Slot 1: x8 full-
height, full length
Processor 1
Slot 4: x16 low
prole, half length Processor 2 N/A N/A
Slot 2: x8 full-
height, full length
Processor 1
Slot 3: x8 full-
height, half length
Processor 1
Riser
conguration 3
(1A+2A)
Two x8 and
three x16 slots
Slot 1: x16 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2
N/A N/A
N/A N/A Slot 5: x8 full-
height, full length
Processor 2
Slot 3: x16 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Riser
conguration 4
(1A+2A+3A)
Three x8 and
four x16 slots
Slot 1: x16 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2 Slot 7: x8 full-
height, full length
Processor
2
N/A N/A Slot 5: x8 full-
height, full length
Processor 2 Slot 8: x16 full-
height, full length
Processor
2
Slot 3: x16 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Riser
conguration 5
(1B+2A+3A)
Six x8 and two
x16 slots
Slot 1: x8 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2 Slot 7: x8 full-
height, full length
Processor
2
Slot 2: x8 full-
height, full length
Processor 1 Slot 5: x8 full-
height, full length
Processor 2 Slot 8: x16 full-
height, full length
Processor
2
Slot 3: x8 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Riser
conguration 6
(1D+2A+3A)
Five x8 and
three x16 slots
Slot1: x16 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2 Slot 7: x8 full-
height, full length
Processor
2
Technical specications 35
Riser
conguration
and supported
risers
Slot description PCIe slots on
riser 1 (Height
and length)
Processor
connection
PCIe slots on riser
2 (Height and
length)
Processor
connection
PCIe slots on
riser 3 (Height
and length)
Processor
connection
Slot 2: x8 full-
height, full length
Processor 1 Slot 5: x8 full-
height, full length
Processor 2
Slot 8: x16 full-
height, full length
Processor
2
Slot 3: x8 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Riser
conguration 9
(1A+2D+3A)
Three x8 and
four x16 slots
Slot 1: x16 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2 Slot 7: x8 full-
height, full length
Processor
2
N/A N/A Slot 5: x8 full-
height, full length
Processor 2 Slot 8: x16 full-
height, full length
Processor
2
Slot 3: x16 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Memory specications
Table 22. Memory specications
Memory module
sockets
DIMM
type DIMM rank DIMM
capacity
Single processor Dual processors
Minimum
RAM
Maximum RAM Minimum RAM Maximum RAM
Twenty four 288-
pins
LRDIMM Octa rank 128 GB 128 GB 1.5 TB 256 GB 3 TB
Quad rank 64 GB 64 GB 768 GB 128 GB 1.5 TB
RDIMM
Single rank 8 GB 8 GB 96 GB 16 GB 192 GB
Dual rank 16 GB 16 GB 192 GB 32 GB 384 GB
Dual rank 32 GB 32 GB 384 GB 64 GB 768 GB
Dual rank 64 GB 64 GB 768 GB 128 GB 1536 GB
NVDIMM
-N
Single rank 16 GB Not supported
with single
processor
Not supported
with single
processor
RDIMM: 192 GB RDIMM: 384 GB
NVDIMM-N: 16
GB
NVDIMM-N: 192
GB
DCPMM
NA 128 GB RDIMM:
192GB
RDIMM: 384
GB
RDIMM: 384 GB LRDIMM: 1536 GB
DCPMM: 128
GB
DCPMM: 128
GB
DCPMM: 1536 GB DCPMM: 1536 GB
NA 256 GB NA NA RDIMM: 384 GB LRDIMM: 1536 GB
NA NA DCPMM: 2048
GB
DCPMM: 3072 GB
NA 512 GB NA NA RDIMM: 384 GB RDIMM: 1536 GB
NA NA DCPMM: 4096
GB
DCPMM: 6144 GB
NOTE: 8 GB RDIMMs and NVDIMM-N must not be mixed.
36 Technical specications
NOTE: 64 GB LRDIMMs, 128 GB LRDIMMs must not be mixed.
NOTE: Minimum of two CPUs are required for any congurations that support NVDIMM-N.
NOTE: DCPMM can be mixed with RDIMMs and LRDIMMs.
NOTE: Mixing of DDR4 DIMM Types (RDIMM, LRDIMM), within channel, integrated memory controller, socket, or across
sockets is not supported.
NOTE: x4 and X8 DDR4 DIMM can be mixed within channel.
NOTE: Mix of Intel Data center persistent memory module operating modes (App Direct, Memory Mode) is not supported within
socket or across sockets.
Storage controller specications
The PowerEdge R740 system supports:
• Internal storage controller cards: PowerEdge RAID Controller (PERC) H330, PERC H730P, PERC H740P, HBA330, S140, and Boot
Optimized Server Storage (BOSS-S1).
The BOSS card is a simple RAID solution card designed specically for booting a server's operating system. The card supports up to
two 6 Gbps M.2 SATA drives. The BOSS adapter card has a x8 connector using PCIe gen 2.0 x2 lanes, available only in the low-prole
and half-height form factor.
• External storage controller cards: PERC H840 and 12Gbps SAS HBA.
Drive specications
Drives
The PowerEdge R740 system supports SAS, SATA, Nearline SAS hard drives or SSDs.
Table 23. Supported drive options for the PowerEdge R740 system
Drives Supported conguration
Eight drives system Up to eight 3.5 inch or 2.5 inch (SAS, SATA or Nearline SAS) front
accessible drives in slots 0 through 7
Sixteen drives system Up to sixteen 2.5 inch (SAS, SATA or Nearline SAS) front accessible drives
in slots 0 through 15
Optical drive
The PowerEdge R740 system supports one optional slim SATA DVD-ROM drive or DVD +/-RW drive.
Ports and connectors specications
USB ports
The PowerEdge R740 system supports:
Technical specications 37
• Two USB 2.0-compliant ports on the front of the system
• One internal USB 3.0-compliant port
• One optional USB 3.0-compliant port on the front of the system
• One micro USB 2.0-compliant port in the front of the system for iDRAC Direct
• Two USB 3.0-compliant ports on the back of the system
NIC ports
The PowerEdge R740 system supports up to four Network Interface Controller (NIC) ports that are integrated on the network daughter
card (NDC), and are available in the following congurations:
• Four RJ-45 ports that support 10, 100 and 1000 Mbps
• Four RJ-45 ports that support 100 M, 1 G and 10 Gbps
• Four RJ-45 ports, where two ports support maximum of 10 G and the other two ports maximum of 1 G
• Two RJ-45 ports that support up to 1 Gbps and 2 SFP+ ports that support up to 10 Gbps
• Four SFP+ ports that support up to 10 Gbps
• Two SFP28 ports that support up to 25 Gbps
NOTE: You can install up to eight PCIe add-on NIC cards.
VGA ports
The Video Graphic Array (VGA) port enables you to connect the system to a VGA display. The PowerEdge R740 system supports two 15-
pin VGA ports on the front and back panels.
Serial connector
The PowerEdge R740 system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE),
16550-compliant.
Internal Dual SD Module or vFlash card
The PowerEdge R740 system supports Internal Dual SD module (IDSDM) and vFlash card. In 14th generation of PowerEdge servers,
IDSDM and vFlash card are combined into a single card module, and are available in these congurations:
• vFlash or
• IDSDM or
• vFlash and IDSDM
The IDSDM/vFlash card sits in the back of the system, in a Dell-proprietary slot. IDSDM/vFlash card supports three micro SD cards (two
cards for IDSDM and one card for vFlash). Micro SD cards capacity for IDSDM are 16/32/64 GB while for vFlash the microSD card
capacity is 16 GB.
Video specications
The PowerEdge R740 system supports integrated Matrox G200eW3 graphics controller with 16 MB of video frame buer.
38 Technical specications
Table 24. Supported video resolution options
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32
NOTE: 1920 x 1080 and 1920 x 1200 resolutions are only supported in reduced blanking mode.
Environmental specications
NOTE: For additional information about environmental certications, please refer to the Product Environmental Datasheet
located with the Manuals & Documents on www.dell.com/poweredgemanuals.
Table 25. Temperature specications
Temperature Specications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117
ft)
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Table 26. Relative humidity specications
Relative humidity Specications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be
non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
Table 27. Maximum vibration specications
Maximum vibration Specications
Operating 0.26 Grms at 5 Hz to 350 Hz (all three axes).
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Technical specications 39
Table 28. Maximum shock specications
Maximum shock Specications
Operating Six consecutively executed shock pulses in the positive and negative x, y,
and z axes of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y,
and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 29. Maximum altitude specications
Maximum altitude Specications
Operating 3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Table 30. Operating temperature de-rating specications
Operating temperature de-rating Specications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m
(3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m
(3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m
(3,117 ft).
Standard operating temperature
Table 31. Standard operating temperature specications
Standard operating temperature Specications
Continuous operation (for altitude less than 950 m or 3117
ft)
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Humidity percentage range 10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point.
Expanded operating temperature
Table 32. Expanded operating temperature specications
Expanded operating temperature Specications
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to
35°C), the system can operate continuously in temperatures as low
as 5°C and as high as 40°C.
40 Technical specications
Expanded operating temperature Specications
For temperatures between 35°C to 40°C, de-rate maximum allowable
temperature by 1°C per 175 m above 950 m (1°F per 319 ft).
≤ 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature (10°C to
35°C), the system can operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-rate maximum allowable
temperature by 1°C per 125 m above 950 m (1°F per 228 ft).
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event
Log.
Expanded operating temperature restrictions
• 128 GB LRDIMM is not supported for FAC.
• Do not perform a cold startup below 5°C.
• The operating temperature specied is for a maximum altitude of 3050 m (10,000 ft).
• 150 W/8 core, 165 W/12 core and higher wattage processor [Thermal Design Power (TDP)>165 W] are not supported.
• Redundant power supply unit is required.
• Non-Dell qualied peripheral cards and/or peripheral cards greater than 25 W are not supported.
• PCIe SSD is not supported.
• NVDIMM-Ns are not supported.
• DCPMMs are not supported.
• GPU is not supported.
• Tape backup unit is not supported.
Thermal restrictions
Following table lists the conguration required for ecient cooling.
Table 33. Thermal restrictions conguration
Conguration Number of
processors
Heatsink Processor/DIMM
blank
DIMM
blanks
Type of air
shroud
Fan
PowerEdge
R740
1 One 1U standard heat sink for
CPU ≤ 125 W
Required Not
required
Standard Four standard
fans and one
blank to cover
two fan slots
One 2U standard heat sink for
CPU > 125 W
PowerEdge
R740
2 Two 1U standard heat sink for
CPU ≤ 125 W
Not required Not
required
Standard Six standard fans
Two 2U standard heat sink for
CPU > 125 W
Technical specications 41
Conguration Number of
processors
Heatsink Processor/DIMM
blank
DIMM
blanks
Type of air
shroud
Fan
PowerEdge
R740 with GPU
2 Two 1U high performance
heat sink
Not required Not
required
GPU air shroud Six high
performance
fans
Ambient temperature limitations
The following table lists congurations that require ambient temperature less than 35°C.
NOTE: The ambient temperature limit must be adhered to ensure proper cooling and to avoid excess CPU throttling, which may
impact system performance.
Table 34. Conguration based ambient temperature restrictions
System Front backplane Processor
Thermal Design
Power (TDP)
Processor heat
sink
Fan type GPU Ambient
restriction
PowerEdge
R740
8 x 3.5 inch SAS/
SATA
150 W/8 core, 165
W/12 core, 200
W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
8 x 2.5 inch SAS/
SATA
150 W/8 core, 165
W/12 core, 200
W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
16 x 2.5 inch SAS/
SATA
150 W/8 core, 165
W/12 core, 200
W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
Particulate and gaseous contamination specications
The following table denes the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If
the levels of particulate or gaseous pollution exceed the specied limitations and result in equipment damage or failure, you may need to
rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 35. Particulate contamination specications
Particulate contamination Specications
Air ltration Data center air ltration as dened by ISO Class 8 per ISO 14644-1 with a
95% upper condence limit.
NOTE: The ISO Class 8 condition applies to data center
environments only. This air ltration requirement does not apply to
IT equipment designed to be used outside a data center, in
environments such as an oce or factory oor.
NOTE: Air entering the data center must have MERV11 or MERV13
ltration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive
particles.
NOTE: This condition applies to data center and non-data center
environments.
42 Technical specications
Particulate contamination Specications
Corrosive dust • Air must be free of corrosive dust.
• Residual dust present in the air must have a deliquescent point less than
60% relative humidity.
NOTE: This condition applies to data center and non-data center
environments.
Table 36. Gaseous contamination specications
Gaseous contamination Specications
Copper coupon corrosion rate <300 Å/month per Class G1 as dened by ANSI/ISA71.04-2013.
Silver coupon corrosion rate <200 Å/month as dened by ANSI/ISA71.04-2013.
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Technical specications 43
Initial system setup and conguration
Setting up your system
Perform the following steps to set up your system:
1 Unpack the system.
2 Install the system into the rack. For more information about installing the system into the rack, see the Rail Installation Guide at
www.dell.com/poweredgemanuals.
3 Connect the peripherals to the system.
4 Connect the system to its electrical outlet.
5 Power on the system by pressing the power button or by using iDRAC.
6 Power on the attached peripherals.
For more information about setting up your system, see the Getting Started Guide that shipped with your system.
iDRAC conguration
The Integrated Dell Remote Access Controller (iDRAC) is designed to make system administrators more productive and improve the overall
availability of Dell systems. iDRAC alerts administrators about system issues and enables them to perform remote system management.
This reduces the need for physical access to the system.
Options to set up iDRAC IP address
To enable communication between your system and iDRAC, you must rst congure the network settings based on your network
infrastructure.
NOTE: For static IP conguration, you must request for it at the time of purchase.
This option is set to DHCP by Default. You can set up the IP address by using one of the following interfaces:
Interfaces Document/Section
iDRAC Settings
utility
Dell Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals
Dell Deployment
Toolkit
Dell Deployment Toolkit User’s Guide at www.dell.com/openmanagemanuals > OpenManage Deployment Toolkit
Dell Lifecycle
Controller
Dell Lifecycle Controller User’s Guide at www.dell.com/poweredgemanuals
Server LCD panel LCD panel section
iDRAC Direct and
Quick Sync 2
(optional)
See Dell Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals
NOTE: To access iDRAC, ensure that you connect the ethernet cable to the iDRAC9 dedicated network port. You can also access
iDRAC through the shared LOM mode, if you have opted for a system that has the shared LOM mode enabled.
4
44 Initial system setup and conguration
Log in to iDRAC
You can log in to iDRAC as:
• iDRAC user
• Microsoft Active Directory user
• Lightweight Directory Access Protocol (LDAP) user
If you have opted for secure default access to iDRAC, you must use the iDRAC secure default password available on the system
Information tag. If you have not opted for secure default access to iDRAC, then use the default user name and password –root and
calvin. You can also log in by using your Single Sign-On or Smart Card.
NOTE: You must have the iDRAC credentials to log in to iDRAC.
NOTE: Ensure that you change the default user name and password after setting up the iDRAC IP address.
NOTE: The Intel Quick Assist Technology (QAT) on the Dell EMC PowerEdge R740 is supported with chipset integration and is
enabled through an optional license. The license les are enabled on the sleds through iDRAC.
For more information about drivers, documentation, and white papers on the Intel QAT, see https://01.org/intel-quickassist-technology.
For more information about logging in to the iDRAC and iDRAC licenses, see the latest Integrated Dell Remote Access Controller User's
Guide at www.dell.com/poweredgemanuals.
You can also access iDRAC by using RACADM. For more information, see the RACADM Command Line Interface Reference Guide at
www.dell.com/poweredgemanuals.
Options to install the operating system
If the system is shipped without an operating system, install a supported operating system by using one of the following resources:
Table 37. Resources to install the operating system
Resources Location
iDRAC www.dell.com/idracmanuals
Lifecycle Controller www.dell.com/idracmanuals > Lifecycle Controller
OpenManage Deployment Toolkit www.dell.com/openmanagemanuals > OpenManage Deployment
Toolkit
Dell certied VMware ESXi www.dell.com/virtualizationsolutions
Installation and How-to videos for supported operating systems on
PowerEdge systems
Supported Operating Systems for Dell EMC PowerEdge systems
Methods to download rmware and drivers
You can download the rmware and drivers by using any of the following methods:
Initial system setup and conguration 45
Table 38. Firmware and drivers
Methods Location
From the Dell EMC support site www.dell.com/support/home
Using Dell Remote Access Controller Lifecycle Controller (iDRAC
with LC)
www.dell.com/idracmanuals
Using Dell Repository Manager (DRM) www.dell.com/openmanagemanuals > Repository Manager
Using Dell OpenManage Essentials (OME) www.dell.com/openmanagemanuals > OpenManage Essentials
Using Dell Server Update Utility (SUU) www.dell.com/openmanagemanuals > Server Update Utility
Using Dell OpenManage Deployment Toolkit (DTK) www.dell.com/openmanagemanuals > OpenManage Deployment
Toolkit
Using iDRAC virtual media www.dell.com/idracmanuals
Downloading drivers and rmware
Dell EMC recommends that you download and install the latest BIOS, drivers, and systems management rmware on your system.
Prerequisite
Ensure that you clear the web browser cache before downloading the drivers and rmware.
Steps
1 Go to www.dell.com/support/home.
2 In the Drivers & Downloads section, type the Service Tag of your system in the Enter a Service Tag or product ID box, and then click
Submit.
NOTE: If you do not have the Service Tag, select Detect Product to allow the system to automatically detect the
Service Tag, or click View products, and navigate to your product.
3 Click Drivers & Downloads.
The drivers that are applicable to your system are displayed.
4 Download the drivers to a USB drive, CD, or DVD.
46 Initial system setup and conguration
Pre-operating system management applications
You can manage basic settings and features of a system without booting to the operating system by using the system rmware.
Topics:
• Options to manage the pre-operating system applications
• System Setup
• Dell Lifecycle Controller
• Boot Manager
• PXE boot
Options to manage the pre-operating system
applications
Your system has the following options to manage the pre-operating system applications:
• System Setup
• Dell Lifecycle Controller
• Boot Manager
• Preboot Execution Environment (PXE)
System Setup
By using the System Setup screen, you can congure the BIOS settings, iDRAC settings, and device settings of your system.
NOTE: Help text for the selected eld is displayed in the graphical browser by default. To view the help text in the text browser,
press F1.
You can access system setup by one of the following:
• Standard graphical browser—The browser is enabled by default.
• Text browser—The browser is enabled by using Console Redirection.
Viewing System Setup
To view the System Setup screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
5
Pre-operating system management applications 47
System Setup details
The System Setup Main Menu screen details are explained as follows:
Option Description
System BIOS Enables you to congure BIOS settings.
iDRAC Settings Enables you to congure the iDRAC settings.
The iDRAC settings utility is an interface to set up and congure the iDRAC parameters by using UEFI (Unied
Extensible Firmware Interface). You can enable or disable various iDRAC parameters by using the iDRAC settings
utility. For more information about this utility, see Integrated Dell Remote Access Controller User’s Guide at
www.dell.com/poweredgemanuals.
Device Settings Enables you to congure device settings.
System BIOS
You can use the System BIOS screen to edit specic functions such as boot order, system password, and setup password, set the SATA
and PCIe NVMe RAID mode, and enable or disable USB ports.
Viewing System BIOS
To view the System BIOS screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If the operating system begins to load before you press F2, wait for the system to nish booting, and then
restart the system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
System BIOS Settings details
The System BIOS Settings screen details are explained as follows:
Option Description
System Information Provides information about the system such as the system model name, BIOS version, and Service Tag.
Memory Settings Provides information and options related to the installed memory.
Processor Settings Provides information and options related to the processor such as speed and cache size.
SATA Settings Provides options to enable or disable the integrated SATA controller and ports.
NVMe Settings Provides options to change the NVMe settings. If the system contains the NVMe drives that you want to
congure in a RAID array, you must set both this eld and the Embedded SATA eld on the SATA Settings menu
to RAID mode. You might also need to change the Boot Mode setting to UEFI. Otherwise, you should set this eld
to Non-RAID mode.
Boot Settings Provides options to specify the Boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS boot settings.
48 Pre-operating system management applications
Option Description
Network Settings Provides options to manage the UEFI network settings and boot protocols.
Legacy network settings are managed from the Device Settings menu.
Integrated Devices Provides options to manage integrated device controllers and ports, species related features and options.
Serial
Communication
Provides options to manage the serial ports, their related features and options.
System Prole
Settings
Provides options to change the processor power management settings, and memory frequency.
System Security Provides options to congure the system security settings, such as system password, setup password, Trusted
Platform Module (TPM) security, and UEFI secure boot. It also manages the power button on the system.
Redundant OS
Control
Sets the redundant OS information for redundant OS control.
Miscellaneous
Settings
Provides options to change the system date and time.
System Information
You can use the System Information screen to view system properties such as Service Tag, system model name, and BIOS version.
Viewing System Information
To view the System Information screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click System Information.
System Information details
The System Information screen details are explained as follows:
Option Description
System Model
Name
Species the system model name.
System BIOS
Version
Species the BIOS version installed on the system.
System
Management
Engine Version
Species the current version of the Management Engine rmware.
System Service Tag Species the system Service Tag.
Pre-operating system management applications 49
Option Description
System
Manufacturer
Species the name of the system manufacturer.
System
Manufacturer
Contact
Information
Species the contact information of the system manufacturer.
System CPLD
Version
Species the current version of the system complex programmable logic device (CPLD) rmware.
UEFI Compliance
Version
Species the UEFI compliance level of the system rmware.
Memory Settings
You can use the Memory Settings screen to view all the memory settings and enable or disable specic memory functions, such as system
memory testing and node interleaving.
Viewing Memory Settings
To view the Memory Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If the operating system begins to load before you press F2, wait for the system to nish booting, and then
restart the system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Memory Settings.
Memory Settings details
The Memory Settings screen details are explained as follows:
Option Description
System Memory
Size
Species the memory size in the system.
System Memory
Type
Species the type of memory installed in the system.
System Memory
Speed
Species the system memory speed.
System Memory
Voltage
Species the system memory voltage.
Video Memory Species the amount of video memory.
System Memory
Testing
Species whether the system memory tests are run during system boot. Options are Enabled and Disabled. This
option is set to Disabled by default.
Memory Operating
Mode
Species the memory operating mode. The options available are Optimizer Mode, Single Rank Spare Mode, Multi
Rank Spare Mode, Mirror Mode, and Dell Fault Resilient Mode. This option is set to Optimizer Mode by default.
50 Pre-operating system management applications
Option Description
NOTE: The Memory Operating Mode option can have dierent default and available options based on the
memory conguration of your system.
NOTE: The Dell Fault Resilient Mode option establishes an area of memory that is fault resilient. This
mode can be used by an operating system that supports the feature to load critical applications or
enables the operating system kernel to maximize system availability.
Current State of
Memory Operating
Mode
Species the current state of the memory operating mode.
Node Interleaving Species if Non-Uniform Memory Architecture (NUMA) is supported. If this eld is set to Enabled, memory
interleaving is supported if a symmetric memory conguration is installed. If this eld is set to Disabled, the system
supports NUMA (asymmetric) memory congurations. This option is set to Disabled by default.
ADDDC Setting Enables or disables ADDDC Setting feature. When Adaptive Double DRAM Device Correction (ADDDC) is enabled,
failing DRAM's are dynamically mapped out. When set to Enabled it can have some impact to system performance
under certain workloads. This feature is applicable for x4 DIMMs only. This option is set to Enabled by default.
Opportunistic Self-
Refresh
Enables or disables opportunistic self-refresh feature. This option is set to Disabled by default.
Persistent Memory This eld controls Persistent Memory on the system. This option is only available if the persistent memory module
is installed in the system.
Persistent Memory details
The Persistent Memory screen details can be found in the NVDIMM-N User Guide and DCPMM User Guideat www.dell.com/
poweredgemanuals.
Processor Settings
You can use the Processor Settings screen to view the processor settings and perform specic functions such as enabling virtualization
technology, hardware prefetcher, logical processor idling.
Viewing Processor Settings
To view the Processor Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Processor Settings.
Processor Settings details
The Processor Settings screen details are explained as follows:
Pre-operating system management applications 51
Option Description
Logical Processor Enables or disables the logical processors and displays the number of logical processors. If this option is set to
Enabled, the BIOS displays all the logical processors. If this option is set to Disabled, the BIOS displays only one
logical processor per core. This option is set to Enabled by default.
CPU Interconnect
Speed
Enables you to govern the frequency of the communication links among the processors in the system.
NOTE: The standard and basic bin processors support lower link frequencies.
The options available are Maximum data rate, 10.4 GT/s, and 9.6 GT/s. This option is set to Maximum data rate
by default.
Maximum data rate indicates that the BIOS runs the communication links at the maximum frequency supported by
the processors. You can also select specic frequencies that the processors support, which can vary.
For best performance, you should select Maximum data rate. Any reduction in the communication link frequency
aects the performance of non-local memory accesses and cache coherency trac. In addition, it can slow access
to non-local I/O devices from a particular processor.
However, if power saving considerations outweigh performance, you might want to reduce the frequency of the
processor communication links. If you do this, you should localize memory and I/O accesses to the nearest NUMA
node to minimize the impact to system performance.
Virtualization
Technology
Enables or disables the virtualization technology for the processor. This option is set to Enabled by default.
Adjacent Cache
Line Prefetch
Optimizes the system for applications that need high utilization of sequential memory access. This option is set to
Enabled by default. You can disable this option for applications that need high utilization of random memory
access.
Hardware
Prefetcher
Enables or disables the hardware prefetcher. This option is set to Enabled by default.
Software
Prefetcher
Enables or disables the software prefetcher. This option is set to Enabled by default.
DCU Streamer
Prefetcher
Enables or disables the Data Cache Unit (DCU) streamer prefetcher. This option is set to Enabled by default.
DCU IP Prefetcher Enables or disables the Data Cache Unit (DCU) IP prefetcher. This option is set to Enabled by default.
Sub NUMA Cluster Enables or disables the Sub NUMA Cluster. This option is set to Disabled by default.
UPI Prefetch Enables you to get the memory read started early on DDR bus. The Ultra Path Interconnect (UPI) Rx path will
spawn the speculative memory read to Integrated Memory Controller (iMC) directly. This option is set to Enabled
by default.
Logical Processor
Idling
Enables you to improve the energy eciency of a system. It uses the operating system core parking algorithm and
parks some of the logical processors in the system which in turn allows the corresponding processor cores to
transition into a lower power idle state. This option can only be enabled if the operating system supports it. It is set
to Disabled by default.
Congurable TDP Enables you to congure the TDP level. The available options are Nominal, Level 1, and Level 2. This option is set
to Nominal by default.
NOTE: This option is only available on certain stock keeping units (SKUs) of the processors.
SST-Performance
Prole
Enables you to recongure the processor using Speed Select Technology.
x2APIC Mode Enables or disables the x2APIC mode. This option is set to Disabled by default.
52 Pre-operating system management applications
Option Description
Dell Controlled
Turbo
Controls the turbo engagement. Enable this option only when System Prole is set to Disabled.
NOTE: Depending on the number of installed processors, there might be up to two processor listings.
Dell AVX Scaling
Technology
Enables you to congure the Dell AVX scaling technology. This option is set to 0 by default.
Number of Cores
per Processor
Controls the number of enabled cores in each processor. This option is set to All by default.
Processor Core
Speed
Species the maximum core frequency of the processor.
Processor Bus
Speed
Displays the bus speed of the processor.
Processor n NOTE: Depending on the number of processors, there might be up to two processors listed.
The following settings are displayed for each processor installed in the system:
Option Description
Family-Model-
Stepping
Species the family, model, and stepping of the processor as dened by Intel.
Brand Species the brand name.
Level 2 Cache Species the total L2 cache.
Level 3 Cache Species the total L3 cache.
Number of Cores Species the number of cores per processor.
Maximum Memory
Capacity
Species the maximum memory capacity per processor.
Microcode Species the microcode.
SATA Settings
You can use the SATA Settings screen to view the settings of SATA devices and enable SATA and PCIe NVMe RAID mode on your system.
Viewing SATA Settings
To view the SATA Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click SATA Settings.
Pre-operating system management applications 53
SATA Settings details
The SATA Settings screen details are explained as follows:
Option Description
Embedded SATA Enables the embedded SATA option to be set to AHCI Mode, or RAID Mode. This option is set to AHCI Mode by
default.
Security Freeze
Lock
Enables you to send Security Freeze Lock command to the embedded SATA drives during POST. This option is
applicable only for AHCI mode. This option is set to Enabled by default.
Write Cache Enables or disables the command for the embedded SATA drives during POST. This option is set to Disabled by
default.
Port n Enables you to set the drive type of the selected device.
For AHCI Mode or RAID Mode, BIOS support is always enabled.
Option Description
Model Species the drive model of the selected device.
Drive Type Species the type of drive attached to the SATA port.
Capacity Species the total capacity of the drive. This eld is undened for removable media
devices such as optical drives.
NVMe Settings
The NVMe settings enable you to set the NVMe drives to either RAID mode or Non-RAID mode.
NOTE: To congure these drives as RAID drives, you must set the NVMe drives and the Embedded SATA option in the SATA
Settings menu to RAID mode. If not, you must set this eld to Non-RAID mode.
Viewing NVMe Settings
To view the NVMe Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click NVMe Settings.
NVMe Settings details
The NVMe Settings screen details are explained as follows:
Option Description
NVMe Mode Enables you to set the NVMe mode. This option is set to Non RAID by default.
54 Pre-operating system management applications
Boot Settings
You can use the Boot Settings screen to set the boot mode to either BIOS or UEFI. It also enables you to specify the boot order.
•UEFI: The Unied Extensible Firmware Interface (UEFI) is a new interface between operating systems and platform rmware. The
interface consists of data tables with platform related information, boot and runtime service calls that are available to the operating
system and its loader. The following benets are available when the Boot Mode is set to UEFI:
– Support for drive partitions larger than 2 TB.
– Enhanced security (e.g., UEFI Secure Boot).
– Faster boot time.
NOTE: You must use only the UEFI boot mode in order to boot from NVMe drives.
•BIOS: The BIOS Boot Mode is the legacy boot mode. It is maintained for backward compatibility.
Viewing Boot Settings
To view the Boot Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Boot Settings.
Boot Settings details
The Boot Settings screen details are explained as follows:
Option Description
Boot Mode Enables you to set the boot mode of the system.
CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not
installed in the same boot mode.
If the operating system supports UEFI, you can set this option to UEFI. Setting this eld to BIOS enables
compatibility with non-UEFI operating systems. This option is set to UEFI by default.
NOTE: Setting this eld to UEFI disables the BIOS Boot Settings menu.
Boot Sequence
Retry
Enables or disables the Boot Sequence Retry feature. If this option is set to Enabled and the system fails to boot,
the system re-attempts the boot sequence after 30 seconds. This option is set to Enabled by default.
Hard-Disk Failover Species the drive that is booted in the event of a drive failure. The devices are selected in the Hard-Disk Drive
Sequence on the Boot Option Setting menu. When this option is set to Disabled, only the rst drive in the list is
attempted to boot. When this option is set to Enabled, all drives are attempted to boot in the order selected in the
Hard-Disk Drive Sequence. This option is not enabled for UEFI Boot Mode. This option is set to Disabled by
default.
Generic USB Boot Enables or disables the USB boot option. This option is set to Disabled by default.
Hard-disk Drive
Placeholder
Enables or disables the Hard-disk drive placeholder option. This option is set to Disabled by default.
Pre-operating system management applications 55
Option Description
BIOS Boot Settings Enables or disables BIOS boot options.
NOTE: This option is enabled only if the boot mode is BIOS.
UEFI Boot Settings Enables or disables UEFI Boot options.
The Boot options include IPv4 PXE and IPv6 PXE. This option is set to IPv4 by default.
NOTE: This option is enabled only if the boot mode is UEFI.
UEFI Boot
Sequence
Enables you to change the boot device order.
Boot Options
Enable/Disable
Enables you to select the enabled or disabled boot devices.
Choosing system boot mode
System Setup enables you to specify one of the following boot modes for installing your operating system:
• BIOS boot mode is the standard BIOS-level boot interface.
• UEFI boot mode (the default), is an enhanced 64-bit boot interface.
1 From the System Setup Main Menu, click Boot Settings, and select Boot Mode.
2 Select the UEFI boot mode you want the system to boot into.
CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not installed in
the same boot mode.
3 After the system boots in the specied boot mode, proceed to install your operating system from that mode.
NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit operating systems
do not support UEFI and can only be installed from the BIOS boot mode.
NOTE: For the latest information about supported operating systems, go to www.dell.com/ossupport.
Changing boot order
About this task
You may have to change the boot order if you want to boot from a USB key or an optical drive. The following instructions may vary if you
have selected BIOS for Boot Mode.
Steps
1 On the System Setup Main Menu screen, click System BIOS > Boot Settings > UEFI/BIOS Boot Settings > UEFI/BIOS Boot
Sequence.
2 Click Boot Option Settings > BIOS > Boot Sequence.
3 Click Exit, and then click Yes to save the settings on exit.
Network Settings
You can use the Network Settings screen to modify UEFI PXE, iSCSI, and HTTP boot settings. The network settings option is available
only in the UEFI mode.
NOTE: BIOS does not control network settings in the BIOS mode. For the BIOS boot mode, the option ROM of the network
controllers handles the network settings.
56 Pre-operating system management applications
Viewing Network Settings
To view the Network Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Network Settings.
Network Settings screen details
The Network Settings screen details are explained as follows:
Option Description
UEFI PXE Settings Options Description
PXE Device n (n =
1 to 4)
Enables or disables the device. When enabled, a UEFI PXE boot option is created for the
device.
PXE Device n
Settings(n = 1 to 4)
Enables you to control the conguration of the PXE device.
UEFI HTTP
Settings Options Description
HTTP Device (n = 1
to 4)
Enables or disables the device. When enabled, a UEFI HTTP boot option is created for the
device.
HTTP Device n
Settings (n = 1 to 4)
Enables you to control the conguration of the HTTP device.
Table 39. HTTP Device n Settings screen details
Option Description
Interface Species the NIC interface used for this device.
Protocol Enables you to select protocol IPv4 or IPv6. This is set
to IPv4 by default.
VLAN Enables or Disable VLAN. This is set to Disabled by
default.
VLAN ID This is set to 1.
VLAN Priority This is set to 0.
URI (will obtain from DHCP server if not specied)
UEFI iSCSI Settings Enables you to control the conguration of the iSCSI device.
Pre-operating system management applications 57
Option Description
Table 40. UEFI iSCSI Settings screen details
Option Description
Connection 1 Species the name of the iSCSI initiator in IQN format.
Connection 2 Enables or disables the iSCSI device. When disabled, a
UEFI boot option is created for the iSCSI device
automatically. This is set to Disabled by default.
Connection 1 Settings Enables you to control the conguration of the iSCSI
device.
Connection 2 Settings Enables you to control the conguration of the iSCSI
device.
Connection order
Integrated Devices
You can use the Integrated Devices screen to view and congure the settings of all integrated devices including the video controller,
integrated RAID controller, and the USB ports.
Viewing Integrated Devices
To view the Integrated Devices screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Integrated Devices.
Integrated Devices details
The Integrated Devices screen details are explained as follows:
Option Description
User Accessible
USB Ports
Congures the user accessible USB ports. Selecting Only Back Ports On disables the front USB ports; selecting
All Ports O disables all front and back USB ports; selecting All Ports O (Dynamic) disables all front and back
USB ports during POST and front ports can be enabled or disabled dynamically by an authorized user or authorized
users without resetting the system.
The USB keyboard and mouse function in certain USB ports during the boot process, depending on the selection.
After the boot process is complete, the USB ports will be enabled or disabled as per the setting.
Internal USB Port Enables or disables the internal USB port. This option is set to On or O. This option is set to On by default.
NOTE: The Internal SD Card Port on the PCIe riser is controlled by Internal USB Port.
58 Pre-operating system management applications
Option Description
iDRAC Direct USB
Port
The iDRAC Direct USB port is managed by iDRAC exclusively with no host visibility. This option is set to ON or
OFF. When set to OFF, iDRAC does not detect any USB devices installed in this managed port. This option is set
to On by default.
Integrated RAID
Controller
Enables or disables the integrated RAID controller. This option is set to Enabled by default.
Integrated Network
Card 1
Enables or disables the integrated network card (NDC). When set to Disabled, the NDC is not available to the
operating system (OS). This option is set to Enabled by default.
NOTE: If set to Disabled (OS), the Integrated NICs might still be available for shared network access by
iDRAC.
I/OAT DMA Engine Enables or disables the I/O Acceleration Technology (I/OAT) option. I/OAT is a set of DMA features designed to
accelerate network trac and lower CPU utilization. Enable only if the hardware and software support the
feature.This option is set to Disabled by default.
Embedded Video
Controller
Enables or disables the use of Embedded Video Controller as the primary display. When set to Enabled, the
Embedded Video Controller is used as the primary display even if add-in graphic cards are installed. When set to
Disabled, an add-in graphics card is used as the primary display. BIOS will output displays to both the primary add-
in video and the embedded video during POST and pre-boot environment. The embedded video is disabled before
the operating system boots. This option is set to Enabled by default.
NOTE: When there are multiple add-in graphic cards installed in the system, the rst card discovered
during PCI enumeration is selected as the primary video. You might have to re-arrange the cards in the
slots in order to control which card is the primary video.
Current State of
Embedded Video
Controller
Displays the current state of the embedded video controller. The Current State of Embedded Video Controller
option is a read-only eld. If the Embedded Video Controller is the only display capability in the system (that is, no
add-in graphics card is installed), then the Embedded Video Controller is automatically used as the primary display
even if the Embedded Video Controller setting is set to Enabled.
SR-IOV Global
Enable
Enables or disables the BIOS conguration of Single Root I/O Virtualization (SR-IOV) devices. This option is set to
Disabled by default.
Internal SD Card
Port
Enables or disables the internal SD card port of the Internal Dual SD Module (IDSDM). This option is set to On by
default.
Internal SD Card
Redundancy
Congures the redundancy mode of the Internal Dual SD Module (IDSDM). When set to Mirror Mode, data is
written on both SD cards. After failure of either card and replacement of the failed card, the data of the active card
is copied to the oine card during the system boot.
When Internal SD Card Redundancy is set to Disabled, only the primary SD card is visible to the OS. This option is
set to Disabled by default.
Internal SD Primary
Card
By default, the primary SD card is selected to be SD Card 1. If SD Card 1 is not present, then the controller selects
SD Card 2 to be the primary SD card.
OS Watchdog
Timer
If your system stops responding, this watchdog timer aids in the recovery of your operating system. When this
option is set to Enabled, the operating system initializes the timer. When this option is set to Disabled (the
default), the timer does not have any eect on the system.
Empty Slot Unhide Enables or disables the root ports of all the empty slots that are accessible to the BIOS and OS. This option is set
to Disabled by default.
Memory Mapped
I/O above 4 GB
Enables or disables the support for the PCIe devices that need large amounts of memory. Enable this option only
for 64-bit operating systems. This option is set to Enabled by default.
Memory Mapped
I/O Base
When set to 12 TB, the system maps the MMIO base to 12 TB. Enable this option for an OS that requires 44 bit
PCIe addressing. When set to 512 GB, the system maps the MMIO base to 512 GB, and reduces the maximum
support for memory to less than 512 GB. Enable this option only for the 4 GPU DGMA issue. This option is set to
56 TB by default.
Slot Disablement Enables or disables the available PCIe slots on your system. The slot disablement feature controls the conguration
of the PCIe cards installed in the specied slot. Slots must be disabled only when the installed peripheral card
Pre-operating system management applications 59
Option Description
prevents booting into the operating system or causes delays in system startup. If the slot is disabled, both the
Option ROM and UEFI drivers are disabled. Only slots that are present on the system are available for control.
Table 41. Slot Disablement
Option Description
Slot 1 Enables or disables the PCIe slot 1. This option is set to
Enabled by default.
Slot 3 Enables or disables or only the boot driver is disabled
for the PCIe slot 3. This option is set to Enabled by
default.
Slot 4 Enables or disables or only the boot driver is disabled
for the PCIe slot 4. This option is set to Enabled by
default.
Slot 5 Enables or disables or only the boot driver is disabled
for the PCIe slot 5. This option is set to Enabled by
default.
Slot 6 Enables or disables or only the boot driver is disabled
for the PCIe slot 6. This option is set to Enabled by
default.
Slot 7 Enables or disables or only the boot driver is disabled
for the PCIe slot 7. This option is set to Enabled by
default.
Slot 8 Enables or disables or only the boot driver is disabled
for the PCIe slot 8. This option is set to Enabled by
default.
Slot Bifurcation Allows Platform Default Bifurcation, Auto Discovery of Bifurcation and Manual Bifurcation Control. The default
is set to Platform Default Bifurcation. The slot bifurcation eld is accessible when set to Manual Bifurcation
Control and is disabled when set to Platform Default Bifurcation or Auto Discovery of Bifurcation.
NOTE: Slot Bifurcation options vary depend on the Riser congurations.
Table 42. Slot Bifurcation
Option Description
Auto Discovery Bifurcation Mode The option is set to Platform Default Bifurcation.
Slot 1 Bifurcation x16 or x8 or x4 or x4x4x8 or x8x4x4 Bifurcation
Slot 3 Bifurcation x16 or x8 or x4 or x4x4x8 or x8x4x4 Bifurcation
Slot 4 Bifurcation x16 or x8 or x4 or x4x4x8 or x8x4x4 Bifurcation
Slot 5 Bifurcation x4 or x8 Bifurcation
Slot 6 Bifurcation x4 or x8 Bifurcation
Slot 7 Bifurcation x4 or x8 Bifurcation
60 Pre-operating system management applications
Option Description
Option Description
Slot 8 Bifurcation x16 or x8 or x4 or x4x4x8 or x8x4x4 Bifurcation
Serial Communication
You can use the Serial Communication screen to view the properties of the serial communication port.
Viewing Serial Communication
To view the Serial Communication screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Serial Communication.
Serial Communication details
The Serial Communication screen details are explained as follows:
Option Description
Serial
Communication Enables you to select serial communication devices (Serial Device 1 and Serial Device 2) in BIOS. BIOS console
redirection can also be enabled, and the port address can be specied. This option is set to Auto by default.
Serial Port Address Enables you to set the port address for serial device. This eld sets the serial port address to either COM1 or
COM2 (COM1=0x3F8, COM2=0x2F8). This option is set to Serial Device1=COM2 or Serial Device 2=COM1 by
default.
NOTE: You can use only Serial Device 2 for the Serial Over LAN (SOL) feature. To use console
redirection by SOL, congure the same port address for console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The serial
MUX setting can independently be changed in iDRAC. Loading the BIOS default settings from within the
BIOS setup utility may not always revert the serial MUX setting to the default setting of Serial Device 1.
External Serial
Connector Enables you to associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote Access
Device by using this option. This option is set to Serial Device 1 by default.
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console redirection by SOL,
congure the same port address for console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The serial
MUX setting can independently be changed in iDRAC. Loading the BIOS default settings from within the
BIOS setup utility may not always revert this setting to the default setting of Serial Device 1.
Pre-operating system management applications 61
Option Description
Failsafe Baud Rate Species the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate
automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed. This
option is set to 115200 by default.
Remote Terminal
Type
Enables you to set the remote console terminal type. This option is set to VT100/VT220 by default.
Redirection After
Boot
Enables or disables the BIOS console redirection when the operating system is loaded. This option is set to
Enabled by default.
System Prole Settings
You can use the System Prole Settings screen to enable specic system performance settings such as power management.
Viewing System Prole Settings
To view the System Prole Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click System Prole Settings.
System Prole Settings details
The System Prole Settings screen details are explained as follows:
Option Description
System Prole Sets the system prole. If you set the System Prole option to a mode other than Custom, the BIOS automatically
sets the rest of the options. You can only change the rest of the options if the mode is set to Custom.This option is
set to Performance Per Watt Optimized (DAPC) by default. DAPC is Dell Active Power Controller.
NOTE: All the parameters on the system prole setting screen are available only when the System Prole
option is set to Custom.
CPU Power
Management
Sets the CPU power management. This option is set to System DBPM (DAPC) by default. DBPM is Demand-
Based Power Management.
Memory Frequency Sets the speed of the system memory. You can select Maximum Performance, Maximum Reliability, or a specic
speed. This option is set to Maximum Performance by default.
Turbo Boost Enables or disables the processor to operate in the turbo boost mode. This option is set to Enabled by default.
C1E Enables or disables the processor to switch to a minimum performance state when it is idle. This option is set to
Enabled by default.
C States Enables or disables the processor to operate in all available power states. This option is set to Disabled by default
for performance prole and is set to Enabled by default for all other proles.
Write Data CRC Enables or disables the Write Data CRC. This option is set to Disabled by default.
62 Pre-operating system management applications
Option Description
Memory Patrol
Scrub
Sets the memory patrol scrub frequency. This option is set to Standard by default.
Memory Refresh
Rate
Sets the memory refresh rate to either 1x or 2x. This option is set to 1x by default.
Uncore Frequency Enables you to select the Processor Uncore Frequency option.Dynamic mode enables the processor to optimize
power resources across cores and uncores during runtime. The optimization of the uncore frequency to either save
power or optimize performance is inuenced by the setting of the Energy Eciency Policy option.
Energy Ecient
Policy
Enables you to select the Energy Ecient Policy option.
The CPU uses the setting to manipulate the internal behavior of the processor and determines whether to target
higher performance or better power savings. This option is set to Balanced Performance by default.
Number of Turbo
Boost Enabled
Cores for Processor
1
NOTE: If there are two processors installed in the system, you will see an entry for Number of Turbo
Boost Enabled Cores for Processor 2.
Controls the number of turbo boost enabled cores for Processor 1. The maximum number of cores is enabled by
default.
Monitor/Mwait Enables the Monitor/Mwait instructions in the processor. This option is set to Enabled for all system proles,
except Custom by default.
NOTE: This option can be disabled only if the C States option in the Custom mode is set to disabled.
NOTE: When C States is set to Enabled in the Custom mode, changing the Monitor/Mwait setting does
not impact the system power or performance.
CPU Interconnect
Bus Link Power
Management
Enables or disables the CPU Interconnect Bus Link Power Management. This option is set to Enabled by default.
PCI ASPM L1 Link
Power
Management
Enables or disables the PCI ASPM L1 Link Power Management. This option is set to Enabled by default.
Intel Persistent
Memory CR QoS
Enables you to select the tunning Recipe 1 for QoS knobs and is recommended for 2-2-2 memory conguration in
active directory, Recipe 2 for QoS knobs and is recommended for other memory conguration in active directory
or Recipe 3 for QoS knobs and is recommended for 1 DIMM per channel conguration. This option is set to
Disabled by default.
Intel Persistent
Memory
Performance
Setting
Enables you to select the NVMe performance settings depending on the workload behavior. If this option is set to
BW Optimized, the performance is optimized for DDR and DDRT bandwidth. If this option is set to Latency
Optimized, the performance is better DDR latency. This option is set to BW Optimized by default.
Pre-operating system management applications 63
System Security
You can use the System Security screen to perform specic functions such as setting the system password, setup password and disabling
the power button.
Viewing System Security
To view the System Security screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click System Security.
System Security Settings details
The System Security Settings screen details are explained as follows:
Option Description
CPU AES-NI Improves the speed of applications by performing encryption and decryption by using the Advanced Encryption
Standard Instruction Set (AES-NI). This option is set to Enabled by default.
System Password Enables you to set the system password. This option is set to Enabled by default and is read-only if the password
jumper is not installed in the system.
Setup Password Enables you to set the system setup password. This option is read-only if the password jumper is not installed in
the system.
Password Status Enables you to lock the system password. This option is set to Unlocked by default.
TPM Security NOTE: The TPM menu is available only when the TPM module is installed.
Enables you to control the reporting mode of the TPM. The TPM Security option is set to O by default. You can
only modify the TPM Status TPM Activation, and the Intel TXT elds if the TPM Status eld is set to either On
with Pre-boot Measurements or On without Pre-boot Measurements.
When TPM 1.2 is installed, the TPM Security option is set to O, On with Pre-boot Measurements, or On
without Pre-boot Measurements.
When TPM 2.0 is installed, the TPM Security option is set to On or O. This option is set to O by default.
TPM Information Enables you to change the operational state of the TPM. This option is set to No Change by default.
TPM Status Species the TPM status.
TPM Command Controls the Trusted Platform Module (TPM). When set to None, no command is sent to the TPM. When set to
Activate, the TPM is enabled and activated. When set to Deactivate, the TPM is disabled and deactivated. When
set to Clear, all the contents of the TPM are cleared. This option is set to None by default.
CAUTION: Clearing the TPM results in the loss of all keys in the TPM. The loss of TPM keys may aect
booting to the operating system.
64 Pre-operating system management applications
Option Description
This eld is read-only when TPM Security is set to O. The action requires an additional reboot before it can take
eect.
TPM Advanced
Settings
This setting is enabled only when TPM Security is set to ON.
Intel(R) TXT Enables you to set the Intel Trusted Execution Technology (TXT) option. To enable the Intel TXT option,
virtualization technology and TPM Security must be enabled with Pre-boot measurements. This option is set to O
by default.
When TPM 2.0 is installed, TPM 2 Algorithm option is available. It enables you to select a hash algorithm from
those supported by the TPM (SHA1, SHA256). TPM 2 Algorithm option must be set to SHA256, to enable TXT.
Power Button Enables you to set the power button on the front of the system. This option is set to Enabled by default.
AC Power Recovery Sets how the system behaves after AC power is restored to the system. This option is set to Last by default.
AC Power Recovery
Delay
Enables you to set the time that the system should take to power up after AC power is restored to the system.
This option is set to Immediate by default.
User Dened Delay
(60 s to 600 s)
Enables you to set the User Dened Delay option when the User Dened option for AC Power Recovery Delay is
selected.
UEFI Variable
Access
Provides varying degrees of securing UEFI variables. When set to Standard (the default), UEFI variables are
accessible in the operating system per the UEFI specication. When set to Controlled, selected UEFI variables are
protected in the environment, and new UEFI boot entries are forced to be at the end of the current boot order.
In-Band
Manageability
Interface
When set to Disabled, this setting will hide the Management Engine's (ME), HECI devices, and the system's IPMI
devices from the operating system. This prevents the operating system from changing the ME power capping
settings, and blocks access to all in-band management tools. All management should be managed through out-of-
band. This option is set to Enabled by default.
NOTE: BIOS update requires HECI devices to be operational and DUP updates require IPMI interface to
be operational. This setting needs to be set to Enabled to avoid updating errors.
Secure Boot Enables Secure Boot, where the BIOS authenticates each pre-boot image by using the certicates in the Secure
Boot Policy. Secure Boot is set to Disabled by default.
Secure Boot Policy When Secure Boot policy is set to Standard, the BIOS uses the system manufacturer key and certicates to
authenticate pre-boot images. When Secure Boot policy is set to Custom, the BIOS uses the user-dened key and
certicates. Secure Boot policy is set to Standard by default.
Secure Boot Mode Enables you to congure how the BIOS uses the Secure Boot Policy Objects (PK, KEK, db, dbx).
If the current mode is set to Deployed Mode, the available options are User Mode and Deployed Mode. If the
current mode is set to User Mode, the available options are User Mode, Audit Mode, and Deployed Mode.
Options Description
User Mode In User Mode, PK must be installed, and BIOS performs signature verication on
programmatic attempts to update policy objects.
BIOS allows unauthenticated programmatic transitions between modes.
Audit Mode In Audit mode, PK is not present. BIOS does not authenticate programmatic updates to
the policy objects, and transitions between modes.
Audit Mode is useful for programmatically determining a working set of policy objects.
Pre-operating system management applications 65
Option Description
Options Description
BIOS performs signature verication on pre-boot images and logs the results in the image
Execution Information Table, but approves the images whether they pass or fail
verication.
Deployed Mode Deployed Mode is the most secure mode. In Deployed Mode, PK must be installed and
the BIOS performs signature verication on programmatic attempts to update policy
objects.
Deployed Mode restricts the programmatic mode transitions.
Secure Boot Policy
Summary
Species the list of certicates and hashes that secure boot uses to authenticate images.
Secure Boot
Custom Policy
Settings
Congures the Secure Boot Custom Policy. To enable this option, set the Secure Boot Policy to Custom.
Creating a system and setup password
Prerequisite
Ensure that the password jumper is enabled. The password jumper enables or disables the system password and setup password features.
For more information, see the System board jumper settings section.
NOTE: If the password jumper setting is disabled, the existing system password and setup password are deleted and you need
not provide the system password to boot the system.
Steps
1 To enter System Setup, press F2 immediately after turning on or rebooting your system.
2 On the System Setup Main Menu screen, click System BIOS > System Security.
3 On the System Security screen, verify that Password Status is set to Unlocked.
4 In the System Password eld, type your system password, and press Enter or Tab.
A message prompts you to reenter the system password.
5 Reenter the system password, and click OK.
6 In the Setup Password eld, type your setup password and press Enter or Tab.
A message prompts you to reenter the setup password.
7 Reenter the setup password, and click OK.
8 Press Esc to return to the System BIOS screen. Press Esc again.
A message prompts you to save the changes.
NOTE: Password protection does not take eect until the system reboots.
Using your system password to secure the system
About this task
If you have assigned a setup password, the system accepts your setup password as an alternate system password.
66 Pre-operating system management applications
Steps
1 Power on or reboot your system.
2 Type the system password and press Enter.
Next step
When Password Status is set to Locked, type the system password and press Enter when prompted at reboot.
NOTE: If an incorrect system password is typed, the system displays a message and prompts you to reenter your password. You
have three attempts to type the correct password. After the third unsuccessful attempt, the system displays an error message
that the system has stopped functioning and must be turned o. Even after you turn o and restart the system, the error
message is displayed until the correct password is entered.
Deleting or changing system and setup password
Prerequisite
NOTE: You cannot delete or change an existing system or setup password if the Password Status is set to Locked.
Steps
1 To enter System Setup, press F2 immediately after turning on or restarting your system.
2 On the System Setup Main Menu screen, click System BIOS > System Security.
3 On the System Security screen, ensure that Password Status is set to Unlocked.
4 In the System Password eld, change or delete the existing system password, and then press Enter or Tab.
5 In the Setup Password eld, alter or delete the existing setup password, and then press Enter or Tab.
NOTE: If you change the system password or setup password, a message prompts you to reenter the new password. If
you delete the system password or setup password, a message prompts you to conrm the deletion.
6 Press Esc to return to the System BIOS screen. Press Esc again, and a message prompts you to save the changes.
Operating with setup password enabled
If Setup Password is set to Enabled, type the correct setup password before modifying the system setup options.
If you do not type the correct password in three attempts, the system displays the following message:
Invalid Password! Number of unsuccessful password attempts: <x> System Halted! Must power down.
Even after you restart the system, the error message is displayed until the correct password is typed. The following options are exceptions:
• If System Password is not set to Enabled and is not locked through the Password Status option, you can assign a system password.
For more information, see the System Security Settings details section.
• You cannot disable or change an existing system password.
NOTE: You can use the password status option with the setup password option to protect the system password from
unauthorized changes.
Pre-operating system management applications 67
Redundant OS Control
In the Redundant OS Control screen you can set the redundant OS information. This enables you to set up a physical recovery disk on the
system.
Viewing Redundant OS Control
To view the Redundant OS Control screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Redundant OS Control.
Redundant OS Control screen details
The Redundant OS Control screen details are explained as follows:
Option Description
Redundant OS
Location
Enables you to select a backup disk from the following devices:
•None
•IDSDM
•Internal SD card
•SATA Ports in AHCI mode
•BOSS PCIe Cards (Internal M.2 Drives)
•Internal USB
NOTE: RAID congurations and NVMe cards not are included as BIOS does not have the ability to
distinguish between individual drives in those congurations.
Redundant OS
State NOTE: This option is disabled if Redundant OS Location is set to None.
When set to Visible, the backup disk is visible to the boot list and OS. When set to Hidden, the backup disk is
disabled and is not visible to the boot list and OS. This option is set to Visible by default.
NOTE: BIOS will disable the device in hardware, so it cannot be accessed by the OS.
Redundant OS Boot NOTE: This option is disabled if Redundant OS Location is set to None or if Redundant OS State is set to
Hidden.
When set to Enabled, BIOS boots to the device specied in Redundant OS Location. When set to Disabled, BIOS
preserves the current boot list settings. This option is set to Disabled by default.
68 Pre-operating system management applications
Miscellaneous Settings
You can use the Miscellaneous Settings screen to perform specic functions such as updating the asset tag and changing the system
date and time.
Viewing Miscellaneous Settings
To view the Miscellaneous Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Miscellaneous Settings.
Miscellaneous Settings details
The Miscellaneous Settings screen details are explained as follows:
Option Description
System Time Enables you to set the time on the system.
System Date Enables you to set the date on the system.
Asset Tag Species the asset tag and enables you to modify it for security and tracking purposes.
Keyboard NumLock Enables you to set whether the system should boot with the NumLock enabled or disabled. This option is set to On
by default.
NOTE: This option does not apply to 84-key keyboards.
F1/F2 Prompt on
Error
Enables or disables the F1/F2 prompt on error. This option is set to Enabled by default. The F1/F2 prompt also
includes keyboard errors.
Load Legacy Video
Option ROM
Enables you to determine whether the system BIOS loads the legacy video (INT 10H) option ROM from the video
controller. Selecting Enabled in the operating system does not support UEFI video output standards. This eld is
available only for UEFI boot mode. You cannot set the option to Enabled if UEFI Secure Boot mode is enabled.
This option is set to Disabled by default.
Dell Wyse P25/P45
BIOS Access
Enables or disables the Dell Wyse P25/P45 BIOS Access. This option is set to Enabled by default.
Power Cycle
Request
Enables or disables the Power Cycle Request. This option is set to None by default.
iDRAC Settings utility
The iDRAC settings utility is an interface to set up and congure the iDRAC parameters by using UEFI. You can enable or disable various
iDRAC parameters by using the iDRAC settings utility.
NOTE: Accessing some of the features on the iDRAC settings utility needs the iDRAC Enterprise License upgrade.
Pre-operating system management applications 69
For more information about using iDRAC, see Dell Integrated Dell Remote Access Controller User's Guide at www.dell.com/
poweredgemanuals.
Device Settings
Device Settings enables you to congure the below device parameters:
• Controller Conguration Utility
• Embedded NIC Port1-X Conguration
• NICs in slotX, Port1-X Conguration
• BOSS Card conguration
Dell Lifecycle Controller
Dell Lifecycle Controller (LC) provides advanced embedded systems management capabilities including system deployment, conguration,
update, maintenance, and diagnosis. LC is delivered as part of the iDRAC out-of-band solution and Dell system embedded Unied
Extensible Firmware Interface (UEFI) applications.
Embedded system management
The Dell Lifecycle Controller provides advanced embedded system management throughout the lifecycle of the system. The Dell Lifecycle
Controller can be started during the boot sequence and can function independently of the operating system.
NOTE: Certain platform congurations may not support the full set of features provided by the Dell Lifecycle Controller.
For more information about setting up the Dell Lifecycle Controller, conguring hardware and rmware, and deploying the operating system,
see the Dell Lifecycle Controller documentation at www.dell.com/poweredgemanuals.
Boot Manager
The Boot Manager screen enables you to select boot options and diagnostic utilities.
Viewing Boot Manager
About this task
To enter Boot Manager:
Steps
1 Power on, or restart your system.
2 Press F11 when you see the following message:
F11 = Boot Manager
If your operating system begins to load before you press F11, allow the system to complete the booting, and then restart your system
and try again.
70 Pre-operating system management applications
Boot Manager main menu
Menu item Description
Continue Normal
Boot
The system attempts to boot to devices starting with the rst item in the boot order. If the boot attempt fails, the
system continues with the next item in the boot order until the boot is successful or no more boot options are
found.
One-shot Boot
Menu
Enables you to access boot menu, where you can select a one-time boot device to boot from.
Launch System
Setup
Enables you to access System Setup.
Launch Lifecycle
Controller
Exits the Boot Manager and invokes the Dell Lifecycle Controller program.
System Utilities Enables you to launch System Utilities menu such as System Diagnostics and UEFI shell.
One-shot UEFI boot menu
One-shot UEFI boot menu enables you to select a boot device to boot from.
System Utilities
System Utilities contains the following utilities that can be launched:
• Launch Diagnostics
• BIOS Update File Explorer
• Reboot System
PXE boot
You can use the Preboot Execution Environment (PXE) option to boot and congure the networked systems, remotely.
To access the PXE boot option, boot the system and then press F12 during POST instead of using standard Boot Sequence from BIOS
Setup. It does not pull any menu or allows managing of network devices.
Pre-operating system management applications 71
Installing and removing system components
Safety instructions
WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system by
yourself.
WARNING: Opening or removing the system cover while the system is powered on may expose you to a risk of electric shock.
CAUTION: Do not operate the system without the cover for a duration exceeding ve minutes. Operating the system without the
system cover can result in component damage.
CAUTION: Many repairs may only be done by a certied service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
NOTE: It is recommended that you always use an antistatic mat and antistatic strap while working on components inside the
system.
CAUTION: To ensure proper operation and cooling, all bays in the system and system fans must be always populated with a
component or a blank.
Before working inside your system
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Turn o the system, including all attached peripherals.
2 Disconnect the system from the electrical outlet and disconnect the peripherals.
3 If applicable, remove the system from the rack.
For more information, see the Rack Installation Guide at www.dell.com/poweredgemanuals.
4 Remove the system cover.
After working inside your system
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Install the system cover.
2 If applicable, install the system into the rack.
For more information, see the Rack Installation Guide at www.dell.com/poweredgemanuals.
3 Reconnect the peripherals and connect the system to the electrical outlet.
4 Turn on the attached peripherals and then turn on the system.
6
72 Installing and removing system components
Recommended tools
You need the following tools to perform the removal and installation procedures:
• Key to the bezel lock
The key is required only if your system includes a bezel.
• Phillips #1 screwdriver
• Phillips #2 screwdriver
• Torx #T30 screwdriver
• 1/4 inch at blade screwdriver
• Wrist-grounding strap connected to the ground
• ESD Mat
You need the following tools to assemble the cables for a DC power supply unit:
• AMP 90871-1 hand-crimping tool or equivalent
• Tyco Electronics 58433-3 or equivalent
• Wire-stripper pliers to remove insulation from size 10 AWG solid or stranded, insulated copper wire
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding).
Optional front bezel
Front bezel details
An optional metal bezel is mounted on the front of the system to display system branding. A lock on the bezel is used to protect
unauthorized access to the drives. There are two versions of bezel available:
• With LCD panel
• Without LCD panel
For bezels with LCD panel, the system status can be viewed on the LCD panel. For more information, see the LCD panel section.
The LCD bezel is hot pluggable and can be used in any server of the same branding even if that system was originally not ordered with that
LCD bezel.
Removing the front bezel
The procedure to remove the front bezel with and without the LCD panel is the same.
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Unlock the bezel by using the bezel key.
2 Press the release button, and pull the left end of the bezel.
3 Unhook the right end, and remove the bezel.
Installing and removing system components 73
Figure 24. Removing the optional front bezel with the LCD panel
Next step
Install the front bezel.
Installing the front bezel
The procedure to install the front bezel with and without the LCD panel is the same.
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Locate and remove the bezel key.
NOTE: The bezel key is part of the LCD bezel package.
2 Align and insert the right end of the bezel onto the system.
3 Press the bezel until the button clicks in place and t the left end of the bezel onto the system.
4 Lock the bezel by using the key.
74 Installing and removing system components
Figure 25. Installing the optional front bezel with the LCD panel
System cover
Removing the system cover
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Turn o the system, including any attached peripherals.
3 Disconnect the system from the electrical outlet and disconnect the peripherals.
Steps
1 Using a 1/4 inch at head or a Phillips #2 screwdriver, rotate the latch release lock counter clockwise to the unlocked position.
2 Lift the latch till the system cover slides back and the tabs on the system cover disengage from the guide slots on the system.
3 Hold the cover on both sides, and lift the cover away from the system.
Installing and removing system components 75
Figure 26. Removing the system cover
Next step
Install the system cover.
Installing the system cover
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Ensure that all internal cables are routed correctly and connected, and no tools or extra parts are left inside the system.
Steps
1 Align the tabs on the system cover with the guide slots on the system.
2 Push the system cover latch down.
The system cover slides forward, the tabs on the system cover engage with the guide slots on the system and the system cover latch
locks into place.
3 Using a 1/4 inch at head or Phillips #2 screwdriver, rotate the latch release lock clockwise to the locked position.
76 Installing and removing system components
Figure 27. Installing system cover
Next steps
1 Reconnect the peripherals and connect the system to the electrical outlet.
2 Turn on the system, including any attached peripherals.
Backplane cover
Removing the backplane cover
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Slide the backplane cover in the direction of the arrows marked on the backplane cover.
2 Lift the backplane cover away from the system.
Installing and removing system components 77
Figure 28. Removing backplane cover
Next step
Install the backplane cover.
Installing the backplane cover
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the tabs on the backplane cover with the guide slots on the system.
2 Slide the backplane cover toward the front of the system until the cover locks into place.
78 Installing and removing system components
Figure 29. Installing the backplane cover
Next step
Follow the procedure listed in After working inside your system.
Inside the system
CAUTION: Many repairs may only be done by a certied service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Installing and removing system components 79
Figure 30. Inside the system
1drive backplane 2 backplane expander card
3 cooling fan in the cooling fan assembly (6) 4 memory module
5 CPU2 processor and heat sink module socket (with dust cover) 6 expansion card riser 3
7 network daughter card 8 expansion card riser 2
9 system board 10 expansion card riser 1
11 integrated storage controller card 12 CPU1 processor and heat sink module
80 Installing and removing system components
Figure 31. Inside the system – Conguration showing air shroud with optional NVDIMM-N battery
1drive backplane 2 backplane expander card
3 cooling fan (6) in the cooling fan assembly 4 air shroud
5 expansion card riser 3 6 network daughter card
7 expansion card riser 2 8 system board
9 expansion card riser 1 10 integrated storage controller card
11 NVDIMM-N battery
Air shroud
Removing the air shroud
Prerequisites
CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in
shutdown of the system and loss of data.
Installing and removing system components 81
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If installed, remove the full length PCIe cards.
4 If applicable, remove the GPU cards.
5 If NVDIMM-N battery is installed, disconnect the cables from the NVDIMM-N battery.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure
that your system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before
disconnecting the NVDIMM-N battery cables.
Step
Hold the air shroud at both ends and lift it away from the system.
Figure 32. Removing air shroud
Next step
If applicable, install the air shroud.
Installing the air shroud
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 If applicable, route the cables inside the system along the system wall and secure the cables by using the cable latch.
Steps
1 Align the tabs on the air shroud with the slots on the system.
2 Lower the air shroud into the system until it is rmly seated.
When rmly seated, the memory socket numbers marked on the air shroud align with the respective memory sockets.
82 Installing and removing system components
Figure 33. Installing air shroud
Next steps
1 If removed, install the full length PCIe cards.
2 If applicable, install the GPU cards.
3 If applicable, connect the cables to the NVDIMM-N battery.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure
that your system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before
connecting the NVDIMM-N battery cables.
4 Follow the procedure listed in After working inside your system.
Cooling fan assembly
Removing the cooling fan assembly
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Lift the release levers to unlock the cooling fan assembly from the system.
2 Hold the release levers, and lift the cooling fan assembly away from the system.
Installing and removing system components 83
Figure 34. Removing the cooling fan assembly
Next step
Install the cooling fan assembly.
Installing the cooling fan assembly
Prerequisite
Follow the safety guidelines listed in Safety instructions.
CAUTION: Ensure that the cables inside the system are correctly installed and retained by the cable retention bracket before
installing the cooling fan assembly. Incorrectly installed cables may get damaged.
Steps
1 Align the guide rails on the cooling fan assembly with the standos on the system.
2 Lower the cooling fan assembly into the system until the cooling fan connectors engage with the connectors on the system board.
3 Press the release levers to lock the cooling fan assembly into the system.
84 Installing and removing system components
Figure 35. Installing the cooling fan assembly
Next step
Follow the procedure listed in After working inside your system.
Cooling fans
Cooling fan details
The cooling fans are integrated into the system to dissipate the heat generated by the functioning of the system. These fans provide
cooling for the processors, expansion cards, and memory modules.
Your system supports up to six standard or high performance hot swappable cooling fans.
For single processor systems, only four standard cooling fans are required. Fan bays one and two are covered by a fan blank.
CAUTION: Mixing of standard and high performance cooling fans is not supported.
NOTE: Each fan is listed in the systems management software, referenced by the respective fan number. If there is a problem
with a particular fan, you can easily identify and replace the proper fan by noting the fan numbers on the cooling fan assembly.
Installing and removing system components 85
Removing a cooling fan
The procedure for removing standard and high performance fans is identical.
Prerequisites
WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise
utmost care while removing or installing cooling fans.
CAUTION: The cooling fans are hot swappable. To maintain proper cooling while the system is on, replace only one fan at a time.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Step
Press the release tab and lift the cooling fan out of the cooling fan assembly.
Figure 36. Removing cooling fan
Next step
If applicable, install the cooling fan.
Installing a cooling fan
The procedure for installing standard and high performance fans is identical.
Prerequisites
WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise
utmost care while removing or installing cooling fans.
CAUTION: The cooling fans are hot swappable. To maintain proper cooling while the system is on, replace only one fan at a time.
Follow the safety guidelines listed in Safety instructions.
Steps
1 Holding the release tab, align the connector at the base of the cooling fan with the connector on the system board.
86 Installing and removing system components
Figure 37. Installing cooling fan
2 Slide the cooling fan into the cooling fan assembly until the release tab locks into place.
Next step
Follow the procedure listed in After working inside your system.
Intrusion switch
Removing an intrusion switch
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the cooling fan assembly.
Step
Press the intrusion switch and slide it out of the intrusion switch slot.
Installing and removing system components 87
Figure 38. Removing an intrusion switch
Next step
Install an intrusion switch.
Installing an intrusion switch
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the tabs on the intrusion switch with the slots on the cooling fan assembly.
2 Push the intrusion switch until it locks in place.
88 Installing and removing system components
Figure 39. Installing an intrusion switch
Next steps
1Install the cooling fan assembly.
2 Follow the procedure listed in After working inside your system.
NVDIMM-N battery
NVDIMM-N battery details
NVDIMM-N battery can be installed on both regular and GPU air shrouds.
Removing the NVDIMM-N battery from the air shroud
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure that your
system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before removing the NVDIMM-N
battery.
CAUTION: To avoid damage to the battery connector, you must rmly support the connector while installing or removing a
battery.
Steps
1 Disconnect the cables from the NVDIMM-N battery.
2 Using Phillips #2 screwdriver, remove the screw securing the NVDIMM-N battery.
3 Holding the edges, lift the NVDIMM-N battery at an angle to disengage it from the slot on the air shroud.
4 Lift the NVDIMM-N battery away from the system.
Installing and removing system components 89
Figure 40. Removing the NVDIMM-N battery from the air shroud
Next step
Install the NVDIMM-N battery into the air shroud.
Installing NVDIMM-N battery into air shroud
Prerequisites
Follow the safety guidelines listed in Safety instructions.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure that your
system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before installing the NVDIMM-N
battery.
CAUTION: To avoid damage to the battery connector, you must rmly support the connector while installing or removing a
battery.
Steps
1 Incline the NVDIMM-N battery at an angle and place the battery on the air shroud slot.
2 Using Phillips #2 screwdriver, tighten the screw to secure the NVDIMM-N battery.
3 Connect the cables to the NVDIMM-N battery.
90 Installing and removing system components
Figure 41. Installing NVDIMM-N battery into air shroud
Next step
Follow the procedure listed in After working inside your system.
Removing NVDIMM-N battery from mid drive tray
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure that your
system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before removing the NVDIMM-N
battery.
CAUTION: To avoid damage to the battery connector, you must rmly support the connector while installing or removing a
battery.
Steps
1 Lift the drive tray handles 90 degrees upward.
2 Using Phillips #2 screwdriver, remove the screw securing the NVDIMM-N battery.
3 Slide the NVDIMM-N battery to disengage it from the drive tray.
4 Disconnect the cables from the NVDIMM-N battery.
5 Holding the edges, lift the NVDIMM-N battery away from the system.
Installing and removing system components 91
Figure 42. Removing NVDIMM-N battery from mid drive tray
Next step
Install NVDIMM-N battery into mid drive tray.
Installing NVDIMM-N battery into mid drive tray
Prerequisites
Follow the safety guidelines listed in Safety instructions.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure that your
system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before installing the NVDIMM-N
battery.
CAUTION: To avoid damage to the battery connector, you must rmly support the connector while installing or removing a
battery.
Steps
1 Connect the cables to the NVDIMM-N battery.
2 Slide the NVDIMM-N battery to engage the battery with the drive tray.
3 Using Phillips #2 screwdriver, tighten the screw to secure the NVDIMM-N battery.
4 Lower the drive tray handle.
92 Installing and removing system components
Figure 43. Installing NVDIMM-N battery into mid drive tray
Next step
Follow the procedure listed in After working inside your system.
Removing NVDIMM-N battery from the bracket
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure that your
system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before removing the NVDIMM-N
battery.
CAUTION: To avoid damage to the battery connector, you must rmly support the connector while installing or removing a
battery.
Step
Press the release tab and slide out the NVDIMM-N battery to disengage the tab on the battery from the slot on the bracket.
Installing and removing system components 93
Figure 44. Removing NVDIMM-N battery from the bracket
Next step
Install NVDIMM-N battery into the bracket..
Installing NVDIMM-N battery into the bracket
Prerequisites
Follow the safety guidelines listed in Safety instructions.
CAUTION: NVDIMM-N battery is not hot swappable. To prevent data loss and potential damage to your system, ensure that your
system, LEDs on system, LEDs on NVDIMM-N and LEDs on NVDIMM-N battery are turned o before installing the NVDIMM-N
battery.
CAUTION: To avoid damage to the battery connector, you must rmly support the connector while installing or removing a
battery.
Steps
1 Align the tab on the NVDIMM-N battery with the slot on the bracket.
2 Insert the battery into the bracket until it is rmly seated.
94 Installing and removing system components
Figure 45. Installing NVDIMM-N battery into the bracket
Next step
Follow the procedure listed in After working inside your system.
Drives
Drive guidelines
Drives are supplied in hot swappable drive carriers that t in the drive slots.
CAUTION: Before attempting to remove or install a drive while the system is running, see the documentation for the storage
controller card to ensure that the host adapter is congured correctly.
CAUTION: Do not turn o or restart your system while a drive is being formatted. Doing so can cause a drive failure.
When you format a drive, allow enough time for the formatting to complete. Be aware that high-capacity drives can take a long time to
format.
Removing a drive blank
The procedure for removing 2.5 inch and 3.5 inch drive blanks is identical.
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 If installed, remove the front bezel.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not supported.
Step
Press the release button, and slide the drive blank out of the drive slot.
Installing and removing system components 95
Figure 46. Removing a drive blank
Next step
1Install a drive or a drive blank
Installing a drive blank
The procedure for installing 2.5 inch and 3.5 inch drive blanks is identical.
Prerequisite
Follow the safety guidelines listed in Safety instructions.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not supported.
Step
Insert the drive blank into the drive slot, and push the blank until the release button clicks into place.
Figure 47. Installing a drive blank
Next step
If removed, install the front bezel.
Removing a drive carrier
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 If applicable, remove the front bezel.
96 Installing and removing system components
3 Using the management software, prepare the drive for removal.
If the drive is online, the green activity or fault indicator ashes while the drive is turning o. When the drive indicators are o, the
drive is ready for removal. For more information, see the documentation for the storage controller.
CAUTION: Before attempting to remove or install a drive while the system is running, see the documentation for the
storage controller card to ensure that the host adapter is congured correctly to support drive removal and insertion.
CAUTION: Mixing drives from previous generations of PowerEdge servers is not supported.
CAUTION: To prevent data loss, ensure that your operating system supports drive installation. See the documentation
supplied with your operating system.
Steps
1 Press the release button to open the drive carrier release handle.
2 Holding the handle, slide the drive carrier out of the drive slot.
Figure 48. Removing a drive carrier
Next steps
1Install a drive carrier.
2 If you are not replacing the drive immediately, insert a drive blank in the empty drive slot to maintain proper system cooling.
Installing a drive carrier
Prerequisites
CAUTION: Before attempting to remove or install a drive while the system is running, see the documentation for the storage
controller card to ensure that the host adapter is congured correctly to support drive removal and insertion.
CAUTION: Mixing drives from previous generations of PowerEdge servers is not supported.
CAUTION: Combining SAS and SATA drives in the same RAID volume is not supported.
CAUTION: When installing a drive, ensure that the adjacent drives are fully installed. Inserting a drive carrier and attempting to
lock its handle next to a partially installed carrier can damage the partially installed carrier's shield spring and make it unusable.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation
supplied with your operating system.
Installing and removing system components 97
CAUTION: When a replacement hot swappable drive is installed and the system is powered on, the drive automatically begins to
rebuild. Ensure that the replacement drive is blank or contains data that you wish to overwrite. Any data on the replacement
drive is immediately lost after the drive is installed.
1 Follow the safety guidelines listed in Safety instructions.
2 If applicable, remove the drive blank.
Steps
1 Press the release button on the front of the drive carrier to open the release handle.
2 Insert the drive carrier into the drive slot and slide until the drive connects with the backplane.
3 Close the drive carrier release handle to lock the drive in place.
Figure 49. Installing a drive carrier
Next step
If removed, install the front bezel.
Removing a 2.5 inch drive from the 3.5 inch drive adapter
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove 3.5 inch drive adapter from the 3.5 inch drive carrier.
NOTE: A 2.5 inch hot swappable drive is installed in a 3.5 inch drive adapter, which is then installed in the 3.5 inch hot swappable
drive carrier.
Steps
1 Using a Phillips #2 screwdriver, remove the screws from the side of the 3.5 inch drive adapter.
2 Remove the drive from the 3.5 inch drive adapter.
98 Installing and removing system components
Figure 50. Removing a 2.5 inch drive from the 3.5 inch drive adapter
Next step
Install a 2.5 inch drive into the 3.5 inch drive adapter.
Installing a 2.5 inch drive into the 3.5 inch drive adapter
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the screw holes on the 2.5 inch drive with the screw holes on the 3.5 inch drive adapter.
2 Using a Phillips #2 screwdriver, install the screws to secure the drive to the 3.5 inch drive adapter.
Installing and removing system components 99
Figure 51. Installing a 2.5 inch drive into the 3.5 inch drive adapter
Next steps
1Install a 3.5 inch adapter into the 3.5 inch drive carrier.
2 Follow the procedure listed in After working inside your system.
Removing a 3.5 inch adapter from a 3.5 inch drive carrier
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the 3.5 inch drive carrier from the system.
Steps
1 Remove the screws from the rails on the drive carrier.
2 Lift the 3.5 inch drive adapter out of the drive carrier.
100 Installing and removing system components
Figure 52. Removing a 3.5 inch adapter from a 3.5 inch drive carrier
Next step
Install a 3.5 inch adapter into a 3.5 inch drive carrier.
Installing a 3.5 inch adapter into a 3.5 inch drive carrier
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Insert the 3.5 inch drive adapter into the drive carrier with the connector end of the drive toward the back of the drive carrier.
2 Align the screw holes on the drive with the holes on the drive carrier.
3 Install the screws to secure the drive to the drive carrier.
Installing and removing system components 101
Figure 53. Installing a 3.5 inch adapter into a 3.5 inch drive carrier
Next steps
1Install a 3.5 inch drive carrier into the system.
2 Follow the procedure listed in After working inside your system.
Removing the drive from the drive carrier
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the safety guidelines listed in Before working inside your system.
CAUTION: Mixing drives from previous generations of PowerEdge servers is not supported.
Steps
1 Using a Phillips #1 screwdriver, remove the screws from the slide rails on the drive carrier.
2 Lift the drive out of the drive carrier.
102 Installing and removing system components
Figure 54. Removing the drive from the drive carrier
Next step
If applicable, install the drive into the drive carrier.
Installing a drive into the drive carrier
Prerequisites
Follow the safety guidelines listed in Safety instructions.
CAUTION: Mixing drive carriers from other generations of PowerEdge servers is not supported.
NOTE: When installing a drive into the drive carrier, ensure that the screws are torqued to 4 in-lbs.
Steps
1 Insert the drive into the drive carrier with the connector end of the drive towards the back of the carrier.
2 Align the screw holes on the drive with the screws holes on the drive carrier.
When aligned correctly, the back of the drive is ush with the back of the drive carrier.
3 Using a Phillips #1 screwdriver, secure the drive to the drive carrier with screws.
Installing and removing system components 103
Figure 55. Installing a drive into the drive carrier
System memory
System memory guidelines
The PowerEdge systems support DDR4 Registered DIMMs (RDIMMs), Load Reduced DIMMs (LRDIMMs), Non-Volatile DIMMs
(NVDIMM-Ns), and DCPMM. System memory holds the instructions that are executed by the processor.
Your system contains 24 memory sockets split into two sets of 12 sockets, one set per processor. Each 12-socket set is organized into six
channels. Six memory channels are allocated to each processor. In each channel, the release tabs of the rst socket are marked white, and
the second socket black.
104 Installing and removing system components
Figure 56. Memory socket locations
Memory channels are organized as follows:
Table 43. Memory channels
Processor Channel 0 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5
Processor 1 Slots A1 and A7 Slots A2 and A8 Slots A3 and A9 Slots A4 and A10 Slots A5 and A11 Slots A6 and A12
Processor 2 Slots B1 and B7 Slots B2 and B8 Slots B3 and B9 Slots B4 and B10 Slots B5 and B11 Slots B6 and B12
Installing and removing system components 105
General memory module installation guidelines
To ensure optimal performance of your system, observe the following general guidelines when conguring your system memory. If your
system's memory congurations fail to observe these guidelines, your system might not boot, stop responding during memory
conguration, or operate with reduced memory.
The memory bus may operate at frequency can be 2933 MT/s, 2666 MT/s, 2400 MT/s, or 2133 MT/s depending on the following factors:
• System prole selected (for example, Performance Optimized, or Custom [can be run at high speed or lower])
• Maximum supported DIMM speed of the processors. For memory frequency of 2933 MT/s, one DIMM per channel is supported.
• Maximum supported speed of the DIMMs
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
The system supports Flexible Memory Conguration, enabling the system to be congured and run in any valid chipset architectural
conguration. The following are the recommended guidelines for installing memory modules:
• All DIMMs must be DDR4.
• RDIMMs and LRDIMMs must not be mixed.
• NVDIMMs and LRDIMMs must not be mixed.
• NVDIMMs and RDIMMs can be mixed.
• 64 GB LRDIMMs that are DDP (Dual Die Package) LRDIMMs must not be mixed with 128 GB LRDIMMs that are TSV (Through Silicon
Via/3DS) LRDIMMs.
• x4 and x8 DRAM based memory modules can be mixed.
• Up to two RDIMMs can be populated per channel regardless of rank count.
• Up to two LRDIMMs can be populated per channel regardless of rank count.
• A maximum of two dierent ranked DIMMs can be populated in a channel regardless of rank count.
• If memory modules with dierent speeds are installed, they will operate at the speed of the slowest installed memory module(s).
• Populate memory module sockets only if a processor is installed.
– For single-processor systems, sockets A1 to A12 are available.
– For dual-processor systems, sockets A1 to A12 and sockets B1 to B12 are available.
• Populate all the sockets with white release tabs rst, followed by the black release tabs.
• When mixing memory modules with dierent capacities, populate the sockets with memory modules with the highest capacity rst.
For example, if you want to mix 8 GB and 16 GB memory modules, populate 16 GB memory modules in the sockets with white release
tabs and 8 GB memory modules in the sockets with black release tabs.
• Memory modules of dierent capacities can be mixed provided other memory population rules are followed.
For example, 8 GB and 16 GB memory modules can be mixed.
• In a dual-processor conguration, the memory conguration for each processor must be identical.
For example, if you populate socket A1 for processor 1, then populate socket B1 for processor 2, and so on.
• Mixing of more than two memory module capacities in a system is not supported.
• Unbalanced memory congurations will result in a performance loss so always populate memory channels identically with identical
DIMMs for best performance.
• Populate six identical memory modules per processor (one DIMM per channel) at a time to maximize performance.
• To ensure proper system cooling, memory module blanks must be installed in memory sockets that are not occupied.
DIMM population update for Performance Optimized mode with quantity of 4 and 8 DIMMs per processor.
• When the DIMM quantity is 4 per processor, the population is slot 1, 2, 4, 5.
• When the DIMM quantity is 8 per processor, the population is slot 1, 2, 4, 5, 7, 8, 10, 11.
106 Installing and removing system components
NVDIMM-N memory module installation guidelines
The following are the recommended guidelines for installing NVDIMM-N memory modules:
• Each system supports memory congurations with 1, 2, 4, 6, or 12 NVDIMM-Ns.
• Supported congurations have dual processors and a minimum of 12x RDIMMs.
• Maximum of 12 NVDIMM-Ns can be installed in a system.
• NVDIMM-Ns or RDIMMs must not be mixed with LRDIMMs.
• DDR4 NVDIMM-Ns must be populated only on the black release tabs on processor 1 and 2.
• All slots on congurations 3, 6, 9, and 12 can be used, but a maximum of 12 NVDIMM-Ns can be installed in a system.
For more information on the supported NVDIMM-N congurations, see the NVDIMM-N User Guide at www.dell.com/poweredgemanuals.
Table 44. Supported NVDIMM-N for dual processor congurations
Conguration Description Memory population rules
RDIMMs NVDIMM-N
Conguration 1 12x 16 GB RDIMMs, 1x
NVDIMM-N Processor1 {A1, 2, 3, 4, 5, 6}
Processor2 {B1, 2, 3, 4, 5, 6}
Processor1 {A7}
Conguration 2 12x 32 GB RDIMMs, 1x
NVDIMM-N
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7}
Conguration 3 23x 32 GB RDIMMs, 1x
NVDIMM-N Processor1 {A1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11, 12}
Processor2 {B1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11}
Processor2 {B12}
Conguration 4 12x 16 GB RDIMMs, 2x
NVDIMM-Ns
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7}
Processor2 {B7}
Conguration 5 12x 32 GB RDIMMs, 2x
NVDIMM-Ns
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7}
Processor2 {B7}
Conguration 6 22x 32 GB RDIMMs, 2x
NVDIMM-Ns Processor1 {A1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11}
Processor2 {B1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11}
Processor1 {A12}
Processor2 {B12}
Conguration 7 12x 16 GB RDIMMs, 4x
NVDIMM-Ns
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7, A8}
Processor2 {B7, B8}
Conguration 8 22x 32 GB RDIMMs, 4x
NVDIMM-Ns
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7, A8}
Processor2 {B7, B8}
Installing and removing system components 107
Conguration Description Memory population rules
RDIMMs NVDIMM-N
Conguration 9 20x 32 GB RDIMMs, 4x
NVDIMM-Ns Processor1 {A1, 2, 3, 4, 5, 6, 7, 8,
9, 10}
Processor2 {B1, 2, 3, 4, 5, 6, 7, 8,
9, 10}
Processor1 {A11, 12}
Processor2 {B11, 12}
Conguration 10 12x 16 GB RDIMMs, 6x
NVDIMM-Ns
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7, 8, 9}
Processor2 {B7, 8, 9}
Conguration 11 12x 32 GB RDIMMs, 6x
NVDIMM-Ns
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7, 8, 9}
Processor2 {B7, 8, 9}
Conguration 12 18x 32 GB RDIMMs, 6x
NVDIMM-Ns Processor1 {1, 2, 3, 4, 5, 6, 7, 8,
9}
Processor2 {1, 2, 3, 4, 5, 6, 7, 8,
9}
Processor1 {A10, 11, 12}
Processor2 {B10, 11, 12}
Conguration 13 12x 16 GB RDIMMs, 12x
NVDIMM-Ns
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7, 8, 9, 10, 11, 12}
Processor2 {B7, 8, 9, 10, 11, 12}
Conguration 14 12x 32 GB RDIMMs, 12x
NVDIMM-Ns
Same for all 12x RDIMM
congurations. See
Conguration 1.
Processor1 {A7, 8, 9, 10, 11, 12}
Processor2 {B7, 8, 9, 10, 11, 12}
DCPMM installation guidelines
The following are the recommended guidelines for installing data center persistent memory module (DCPMM) memory modules:
• Each system supports maximum of one DCPMM memory module per channel.
NOTE: If two dierent DIMMs are mixed, an F1/F2 warning is displayed as the conguration is not
supported.
• DCPMM can be mixed with RDIMM, LRDIMM, and 3DS LRDIMM.
• Mixing of DDR4 DIMM types (RDIMM, LRDIMM, and 3DS LRDIMM), within channels, for Integrated Memory Controller (iMC), or
across sockets are not supported.
• Mixing of DCPMM operating modes (App Direct, Memory Mode) is not supported.
• If only one DIMM is populated on a channel, it should always go to the rst slot in that channel (white slot).
• If a DCPMM and a DDR4 DIMM are populated on the same channel, always plug DCPMM on second slot (black slot).
• If the DCPMM is congured in Memory Mode, the recommended DDR4 to DCPMM capacity ratio is 1:4 to 1:16 per iMC.
• DCPMMs cannot be mixed with other DCPMMs or NVDIMMs
• Mixing dierent capacities of RDIMMs and LRDIMMs are not allowed when DCPMM is installed.
• DCPMMs of dierent capacities are not allowed.
For more information about the supported DCPMM congurations, see the DCPMM User Guide at https://www.dell.com/support/
home/us/en/19/products/server_int/server_int_poweredge.
108 Installing and removing system components
Table 45. DCPMM specications
Modes DCPMM
size
DCPMM per
processor
DRAM
DIMM type
DRAM
DIMM size
DRAM
DIMMs per
processor
Total
capacity per
processor
Dual
processors OS
capacity
Memory mode
congurations
128 GB 6 RDIMM 32 GB 6 960 GB 1.5 TB
256 GB 6 RDIMM 32 GB 6 1.68 TB 3 TB
256 GB 6 RDIMM/
LRDIMM
64 GB 6 1.87 TB 3 TB
512 GB 6 RDIMM/
LRDIMM
64 GB 6 2.37 TB 6 TB
512 GB 6 LRDIMM 128 GB 6 3.75 TB 6 TB
Application direct mode
congurations
128 GB 6 RDIMM 32 GB 6 960 GB 1.87 TB
128 GB 6 RDIMM/
LRDIMM
64 GB 6 1.12 TB 2.25 TB
128 GB 6 LRDIMM 128 GB 6 1.5 TB 3 TB
256 GB 4 RDIMM 32 GB 6 1.18 TB 2.37 TB
256 GB 6 RDIMM 32 GB 6 1.68 TB 3.37 TB
256 GB 4 RDIMM/
LRDIMM
64 GB 6 1.37 TB 2.75 TB
256 GB 6 RDIMM/
LRDIMM
64 GB 6 1.87 TB 3.75 TB
256 GB 6 LRDIMM 128 GB 6 2.25 TB 4.5 TB
512 GB 4 RDIMM 32 GB 6 2.18 TB 4.37 TB
512 GB 6 RDIMM 32 GB 6 3.18 TB 6.37 TB
512 GB 4 RDIMM/
LRDIMM
64 Gb 6 2.37 TB 4.75 TB
512 GB 6 RDIMM/
LRDIMM
64 GB 6 3.37 TB 6.75 TB
512 GB 6 LRDIMM 128 GB 6 3.75 TB 7.5 TB
Mode-specic guidelines
The congurations allowed depend on the memory mode selected in the System BIOS.
Table 46. Memory operating modes
Memory Operating Mode Description
Optimizer Mode The Optimizer Mode if enabled, the DRAM controllers operate
independently in the 64-bit mode and provide optimized memory
performance.
Installing and removing system components 109
Memory Operating Mode Description
NOTE: DCPMM supports only Optimizer mode.
Mirror Mode The Mirror Mode if enabled, the system maintains two identical
copies of data in memory, and the total available system memory is
one half of the total installed physical memory. Half of the installed
memory is used to mirror the active memory modules. This feature
provides maximum reliability and enables the system to continue
running even during a catastrophic memory failure by switching
over to the mirrored copy. The installation guidelines to enable
Mirror Mode require that the memory modules be identical in size,
speed, and technology, and they must be populated in sets of 6 per
processor.
Single Rank Spare Mode Single Rank Spare Mode allocates one rank per channel as a spare.
If excessive correctable errors occur in a rank or channel, while the
operating system is running, they are moved to the spare area to
prevent errors from causing an uncorrectable failure. Requires two
or more ranks to be populated in each channel.
Multi Rank Spare Mode Multi Rank Spare Mode allocates two ranks per channel as a spare.
If excessive correctable errors occur in a rank or channel, while the
operating system is running, they are moved to the spare area to
prevent errors from causing an uncorrectable failure. Requires three
or more ranks to be populated in each channel.
With single rank memory sparing enabled, the system memory
available to the operating system is reduced by one rank per
channel.
For example, in a dual-processor conguration with 24x 16 GB dual-
rank memory modules, the available system memory is: 3/4 (ranks/
channel) × 24 (memory modules) × 16 GB = 288 GB, and not 24
(memory modules) × 16 GB = 384 GB. For multi rank sparing, the
multiplier changes to 1/2 (ranks/channel).
NOTE: To use memory sparing, this feature must be
enabled in the BIOS menu of System Setup.
NOTE: Memory sparing does not oer protection against a
multi-bit uncorrectable error.
Dell Fault Resilient Mode The Dell Fault Resilient Mode if enabled, the BIOS creates an area
of memory that is fault resilient. This mode can be used by an OS
that supports the feature to load critical applications or enables the
OS kernel to maximize system availability.
Optimizer Mode
This mode supports Single Device Data Correction (SDDC) only for memory modules that use x4 device width. It does not impose any
specic slot population requirements.
• Dual processor: Populate the slots in round robin sequence starting with processor 1.
NOTE: Processor 1 and processor 2 population should match.
110 Installing and removing system components
Table 47. Memory population rules
Processor Conguration Memory population Memory population information
Single processor Optimizer (Independent
channel) population order
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,
12 • DIMMs must be populated in the order
specied.
• Odd number of DIMM population is allowed
NOTE: Odd number of DIMMs will
result in unbalanced memory
congurations, which in turn will
result in performance loss. It is
recommended to populate all
memory channels identically with
identical DIMMs for best
performance.
• Optimizer population order is not traditional for
4 and 8 DIMM installations of single processor.
– For 4 DIMMs: A1, A2, A4, A5
– For 8 DIMMs: A1, A2, A4, A5, A7, A8, A10,
A11
Mirror population order {1, 2, 3, 4, 5, 6} {7, 8, 9, 10,
11, 12}
Mirroring is supported with 6 or 12 DIMMs per
processor.
Single rank sparing
population order
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,
12 • DIMMs must be populated in the order
specied.
• Requires two ranks or more per channel.
Multi rank sparing
population order
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,
12 • DIMMs must be populated in the order
specied.
• Requires three ranks or more per channel.
Fault resilient population
order
{1, 2, 3, 4, 5, 6} {7, 8, 9, 10,
11, 12}
Supported with 6 or 12 DIMMs per processor.
Dual processor (Start
with processor1.
processor1 and
processor 2 population
should match)
Optimized (Independent
channel) population order A{1}, B{1},
A{2}, B{2},
A{3}, B{3},
A{4}, B{4},
A{5}, B{5},
A{6}, B{6}
Odd number of DIMM population per processor is
allowed.
NOTE: Odd number of DIMMs will result in
unbalanced memory congurations, which
in turn will result in performance loss. It is
recommended to populate all memory
channels identically with identical DIMMs
for best performance.
Optimizer population order is not traditional for 8
and 16 DIMMs installations for dual processor.
• For 8 DIMMs: A1, A2, A4, A5, B1, B2, B4, B5
• For 16 DIMMs:
A1, A2, A4, A5, A7, A8, A10, A11
B1, B2, B4, B5, B7, B8, B10, B11
Mirroring population order A{1, 2, 3, 4, 5, 6},
B{1, 2, 3, 4, 5, 6},
A{7, 8, 9, 10, 11, 12},
B{7, 8, 9, 10, 11, 12}
Mirroring is supported with 6 or 12 DIMMs per
processor.
Installing and removing system components 111
Processor Conguration Memory population Memory population information
Single rank sparing
population order A{1}, B{1},
A{2}, B{2},
A{3}, B{3},
A{4}, B{4},
A{5}, B{5},
A{6}, B{6}
• DIMMs must be populated in the order
specied.
• Requires two ranks or more per channel.
Multi rank sparing
population order A{1}, B{1},
A{2}, B{2},
A{3}, B{3},
A{4}, B{4},
A{5}, B{5},
A{6}, B{6}
• DIMMs must be populated in the order
specied.
• Requires three ranks or more per channel.
Fault resilient population
order A{1, 2, 3, 4, 5, 6},
B{1, 2, 3, 4, 5, 6},
A{7, 8, 9, 10, 11, 12},
B{7, 8, 9, 10, 11, 12}
Supported with 6 or 12 DIMMs per processor.
Removing a memory module
The procedure for removing a DIMM module and an NVDIMM-N module is identical.
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If applicable, remove the air shroud
WARNING: Allow the memory modules to cool after you power o the system. Handle the memory modules by the card edges
and avoid touching the components or metallic contacts on the memory module.
CAUTION: To ensure proper system cooling in congurations with mid drive tray, memory module blanks must be installed in any
memory socket that is not occupied. Remove memory module blanks only if you intend to install memory modules in those
sockets.
NOTE: You must follow the thermal restriction while using DIMM blank. For information about thermal restriction, see the
Thermal restrictions section.
Steps
1 Locate the appropriate memory module socket.
CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the memory
module or metallic contacts.
2 Push the ejectors outward on both ends of the memory module socket to release the memory module from the socket.
3 Lift and remove the memory module from the system.
112 Installing and removing system components
Figure 57. Removing a memory module
Next step
1Install the memory module.
NOTE: For single processor systems, install processor/DIMM blank on CPU2 socket.
Installing a memory module
The procedure for installing a DIMM module and an NVDIMM-N module is identical.
Prerequisites
Follow the safety guidelines listed in Safety instructions.
CAUTION: Ensure that you install the NVDIMM-N battery if you are using NVDIMM-N.
CAUTION: To prevent data loss and potential damage to your system, ensure that your system, LEDs on system, LEDs on
NVDIMM-N and LEDs on NVDIMM-N battery are turned o before installing the NVDIMM-N battery.
Steps
1 Locate the appropriate memory module socket.
CAUTION: Handle each memory module only by the card edges, ensuring not to touch the middle of the memory
module or metallic contacts.
CAUTION: To prevent damage to the memory module or the memory module socket during installation, do not bend or
ex the memory module. You must insert both ends of the memory module simultaneously.
2 Open the ejectors on the memory module socket outward to allow the memory module to be inserted into the socket.
3 Align the edge connector of the memory module with the alignment key of the memory module socket, and insert the memory module
in the socket.
CAUTION: Do not apply pressure at the center of the memory module; apply pressure at both ends of the memory
module evenly.
NOTE: The memory module socket has an alignment key that enables you to install the memory module in the socket in
only one orientation.
4 Press the memory module with your thumbs until the socket levers rmly click into place.
Next steps
1Install the air shroud
2 Follow the procedure listed in After working inside your system.
Installing and removing system components 113
3 To verify if the memory module has been installed properly, press F2 and navigate to System Setup Main Menu > System BIOS >
Memory Settings. In the Memory Settings screen, the System Memory Size must reect the updated capacity of the installed
memory.
4 If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory module is rmly
seated in the memory module socket.
5 Run the system memory test in system diagnostics.
Processors and heat sinks
Removing a processor and heat sink module
Prerequisites
WARNING: The heat sink may be hot to touch for some time after the system is powered down. Allow the heat sink to cool
before removing it.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If applicable, remove the air shroud
4 If applicable, close the PCIe card holder latch on the air shroud to release the full length card.
Steps
1 Using a Torx #T30 screwdriver, loosen the screws on the heat sink in the order below:
a Loosen the rst screw three turns.
b Loosen the second screw completely.
c Return to the rst screw and loosen it completely.
NOTE: It is normal for the heat sink to slip o the blue retention clips when the screws are partially
loosened, continue to loosen the screw(s).
2 Pushing both blue retention clips simultaneously, lift the processor and heat sink module (PHM) out of the system.
3 Set the PHM aside with the processor side facing up.
Figure 58. Removing a processor and heat sink module (2U)
114 Installing and removing system components
Next step
Install the processor and heat sink module.
Removing the processor from the processor and heat sink
module
Prerequisites
NOTE: Only remove the processor from the processor and heat sink module if you are replacing the processor or heat sink. This
procedure is not required when replacing a system board.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the processor and heat sink module.
Steps
1 Place the heat sink with the processor side facing up.
2 Insert a at blade screwdriver into the release slot marked with a yellow label. Twist (do not pry) the screwdriver to break the thermal
paste seal.
3 Push the retaining clips on the processor bracket to unlock the bracket from the heat sink.
Figure 59. Loosening the processor bracket
4 Lift the bracket and the processor away from the heat sink, and place the processor connector side down on the processor tray.
5 Flex the outer edges of the bracket to release the bracket from the processor.
NOTE: Ensure that the processor and the bracket are placed in the tray after you remove the heat sink.
Installing and removing system components 115
Figure 60. Removing the processor bracket
Next step
Install the processor into a processor and heat sink module.
Installing the processor into a processor and heat sink module
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Place the processor in the processor tray.
NOTE: Ensure that the pin 1 indicator on the processor tray is aligned with the pin 1 indicator on the processor.
2 Flex the outer edges of the bracket around the processor ensuring that the processor is locked into the clips on the bracket.
NOTE: Ensure that the pin 1 indicator on the bracket is aligned with the pin 1 indicator on the processor before placing
the bracket on the processor.
NOTE: Ensure that the processor and the bracket are placed in the tray before you install the heat sink.
116 Installing and removing system components
Figure 61. Installing the processor bracket
3 If you are using an existing heat sink, remove the thermal grease from the heat sink by using a clean lint-free cloth.
4 Use the thermal grease syringe included with your processor kit to apply the grease in a quadrilateral design on the top of the
processor.
CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and contaminating the
processor socket.
NOTE: The thermal grease syringe is intended for single use only. Dispose the syringe after you use it.
Figure 62. Applying thermal grease on top of the processor
Installing and removing system components 117
5 Place the heat sink on the processor and push down on the base of the heat sink until the bracket locks onto the heat sink.
NOTE:
• Ensure that the two guide pin holes on the bracket match the guide holes on the heat sink.
• Do not press on the heat sink ns.
• Ensure that the pin 1 indicator on the heat sink is aligned with the pin 1 indicator on the bracket before placing the heat
sink onto the processor and bracket.
Figure 63. Installing the heat sink onto the processor
Next step
Install the processor and heat sink module.
Installing a processor and heat sink module
Prerequisites
CAUTION: Never remove the heat sink from a processor unless you intend to replace the processor. The heat sink is necessary to
maintain proper thermal conditions.
WARNING: The heat sink may be hot to touch for some time after the system has been powered down. Allow the heat sink to
cool before removing it.
1 Follow the safety guidelines listed in Safety instructions.
2 If installed, remove the processor blank and CPU dust cover.
The procedure to remove the processor/DIMM blank is similar to that of the memory module.
Steps
1 Align the pin 1 indicator of the heat sink to the system board and then place the processor and heat sink module (PHM) on the
processor socket.
118 Installing and removing system components
CAUTION: To avoid damaging the ns on the heat sink, do not press down on the heat sink
ns.
NOTE: Ensure that the PHM is held parallel to the system board to prevent damaging the components.
2 Push the blue retention clips inward to allow the heat sink to drop into place.
3 Using the Torx #T30 screwdriver, tighten the screws on the heat sink in the order below:
a Partially tighten the rst screw (approximately 3 turns).
b Tighten the second screw completely.
c Return to the rst screw and tighten it completely.
If the PHM slips o the blue retention clips when the screws are partially tightened, follow these steps to secure the PHM:
a Loosen both the heat sink screws completely.
b Lower the PHM on to the blue retention clips, following the procedure described in step 2.
c Secure the PHM to the system board, following the replacement instructions listed in this step above. 4.
NOTE: The processor and heat sink module retention screws should not be tightened to more than 0.13 kgf-m (1.35 N.m
or 12 in-lbf).
Figure 64. Installing the processor and heat sink module (2U)
Next steps
1 If applicable, install the air shroud.
NOTE: If applicable, open the PCIe card holder latch on the air shroud to install the full length card.
2 Follow the procedure listed in After working inside your system.
Expansion cards and expansion card risers
Expansion card installation guidelines
NOTE: A System Event Log (SEL) event is logged if an expansion card riser is not supported or missing. It does not prevent your
system from turning on. However, if a F1/F2 pause occurs and an error message is displayed.
Installing and removing system components 119
The PowerEdge R740 system supports up to eight PCI express (PCIe) generation 3 expansion cards, that can be installed on the system
board using expansion card risers. The following table provides detailed information about the expansion card riser specications:
Table 48. Expansion card riser specications
Riser
conguration
and supported
risers
Slot description PCIe slots on
riser 1 (Height
and length)
Processor
connection
PCIe slots on riser
2 (Height and
length)
Processor
connection
PCIe slots on
riser 3 (Height
and length)
Processor
connection
Riser
conguration 0
(No riser)
No PCIe slots
(only rear
storage)
N/A N/A N/A N/A N/A N/A
Riser
conguration 1
(1B+2B)
Four x8 slots
Slot 1: x8 full-
height, full length
Processor 1
Slot 4: x8 low
prole, half length Processor 1 N/A N/A
Slot 2: x8 full-
height, full length
Processor 1
Slot 3: x8 full-
height, half length
Processor 1
Riser
conguration 2
(1B+2C)
Three x8 and
one x16 slots
Slot 1: x8 full-
height, full length
Processor 1
Slot 4: x16 low
prole, half length Processor 2 N/A N/A
Slot 2: x8 full-
height, full length
Processor 1
Slot 3: x8 full-
height, half length
Processor 1
Riser
conguration 3
(1A+2A)
Two x8 and
three x16 slots
Slot 1: x16 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2
N/A N/A
N/A N/A Slot 5: x8 full-
height, full length
Processor 2
Slot 3: x16 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Riser
conguration 4
(1A+2A+3A)
Three x8 and
four x16 slots
Slot 1: x16 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2 Slot 7: x8 full-
height, full length
Processor
2
N/A N/A Slot 5: x8 full-
height, full length
Processor 2 Slot 8: x16 full-
height, full length
Processor
2
Slot 3: x16 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Riser
conguration 5
(1B+2A+3A)
Six x8 and two
x16 slots
Slot 1: x8 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2 Slot 7: x8 full-
height, full length
Processor
2
Slot 2: x8 full-
height, full length
Processor 1 Slot 5: x8 full-
height, full length
Processor 2 Slot 8: x16 full-
height, full length
Processor
2
Slot 3: x8 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Riser
conguration 6
(1D+2A+3A)
Five x8 and
three x16 slots
Slot1: x16 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2 Slot 7: x8 full-
height, full length
Processor
2
Slot 2: x8 full-
height, full length
Processor 1 Slot 5: x8 full-
height, full length
Processor 2 Slot 8: x16 full-
height, full length
Processor
2
120 Installing and removing system components
Riser
conguration
and supported
risers
Slot description PCIe slots on
riser 1 (Height
and length)
Processor
connection
PCIe slots on riser
2 (Height and
length)
Processor
connection
PCIe slots on
riser 3 (Height
and length)
Processor
connection
Slot 3: x8 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Riser
conguration 9
(1A+2D+3A)
Three x8 and
four x16 slots
Slot 1: x16 full-
height, full length
Processor 1 Slot 4: x16 full-
height, full length
Processor 2 Slot 7: x8 full-
height, full length
Processor
2
N/A N/A Slot 5: x8 full-
height, full length
Processor 2 Slot 8: x16 full-
height, full length
Processor
2
Slot 3: x16 full-
height, half length
Processor 1 Slot 6: x8 low
prole, half length
Processor 1
Table 49. Riser congurations with 4 PCIe slots [Riser conguration 1 (1B+2B) and Riser conguration 2 (1B+2C)]
Card Type Slot priority Maximum number of cards
GPU (double width) N/A N/A
GPU (single width) N/A N/A
PCIe Bridge 4 1
Internal storage adapter 4 1
Express Flash NVMe PCIe SSD adapter 1, 2, 3, 4 4
HCA EDR 4 1
100 GB NIC 4 1
100 G OPA 4 1
HCA FDR 4 1
40 GB NIC 1, 2, 3 3
40 GB NIC 4 1
HBA FC32 1, 2, 3 3
HBA FC32 4 1
25 GB NIC 1, 2, 3 3
25 GB NIC 4 1
HBA FC16 1, 2, 3 3
HBA FC16 4 1
10 GB NIC 1, 2, 3 3
10 GB NIC 4 1
HBA FC8 1, 2, 3 3
HBA FC8 4 1
1 GB NIC 1, 2, 3 3
1 GB NIC 4 1
External storage adapter 1, 2, 3 3
Installing and removing system components 121
Card Type Slot priority Maximum number of cards
External storage adapter 4 1
BOSS 1, 2, 3 1
BOSS 4 1
ACLR (Full Height DW) NA 0
Table 50. Riser congurations with greater than 4 PCIe slots [Riser conguration 3 (1A+2A), Riser conguration 4 (1A+2A+3A), Riser
conguration 5 (1B+2A+3A), Riser conguration 6 (1D+2A+3A) and Riser conguration 9 (1A+2D+3A)]
Card Type Slot priority Maximum number of cards
GPU (double width) 1, 8, 4 3
GPU (single width) 1, 8, 4, 7, 2, 5 6
PCIe Bridge 1, 3, 4, 8 3
Internal storage adapter 6, 5 1
Express Flash NVMe PCIe SSD adapter 7, 2, 3, 5, 1, 8, 4, 6 6
HCA EDR 1, 8, 4 3
100 GB NIC 1, 8, 4 3
100 G OPA 1, 8, 4 3
HCA FDR 6 1
40 GB NIC 7, 2, 3, 5, 1, 8, 4 7
40 GB NIC 6 1
HBA FC32 7, 2, 3, 5, 1, 8, 4 7
HBA FC32 6 1
25 GB NIC 7, 2, 3, 5, 1, 8, 4 3
25 GB NIC 6 1
HBA FC16 7, 2, 3, 5, 1, 8, 4 7
HBA FC16 6 1
10 GB NIC 7, 2, 3, 5, 1, 8, 4 7
10 GB NIC 6 1
HBA FC8 7, 2, 3, 5, 1, 8, 4 7
HBA FC8 6 1
1 GB NIC 7, 2, 3, 5, 1, 8, 4 7
1 GB NIC 6 1
External storage adapter 7, 2, 3, 5, 1, 8, 4 7
External storage adapter 6 1
BOSS 7, 2, 3, 5, 1, 8, 4 1
BOSS 6 1
Internal storage 7, 2, 3, 5, 1, 8, 4, 6 6
122 Installing and removing system components
Card Type Slot priority Maximum number of cards
ACLR (Full Height DW) 1,8,4 3
NOTE: For information about slot form factor, see the Expansion card riser congurations table.
NOTE: The expansion card slots are not hot-swappable.
NOTE: Double width GPUs are supported only on riser conguration 4, and single width GPUs are supported only on riser
conguration 6.
NOTE: Ensure that x16 cards are installed only in x16 slots. Depending on the riser conguration slots 2, 7, or 8 may not be
available.
NOTE: Only half length PCIe cards are supported on riser 2 when NVDIMM-Ns with NVDIMM-N battery are installed on the air
shroud.
NOTE: For congurations that support GPU, maximum four single-wide and two double-wide GPUs are supported when
NVDIMM-Ns with NVDIMM-N battery are installed. Since NVDIMM-N battery is installed on the GPU shroud, GPUs are not
supported on riser 2.
Opening and closing the PCIe card holder latch
Before installing or removing a full length PCIe card, the PCIe card holder latch must be closed. When the full length PCIe card is installed,
open the PCIe card holder latch.
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 To open the PCIe card holder latch, press the release tab.
Installing and removing system components 123
Figure 65. Opening the PCIe card holder latch
2 To close the PCIe card holder latch, push the latch until it locks.
124 Installing and removing system components
Figure 66. Closing the PCIe card holder latch
Next step
Follow the procedure listed in After working inside your system.
Removing expansion card from the expansion card riser
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If applicable, remove the air shroud.
4 If applicable, disconnect the cables from the expansion card.
5 When removing a card from riser 2 or 3, ensure that the PCIe card holder latch is closed.
Steps
1 Pull the expansion card latch out of the slot.
2 Hold the expansion card by its edges, and pull the card until the card edge connector disengages from the expansion card connector
on the riser.
Installing and removing system components 125
Figure 67. Removing the expansion card from expansion card riser 1
Figure 68. Removing the expansion card from expansion card riser 2B
126 Installing and removing system components
Figure 69. Removing the expansion card from expansion card riser 2
Figure 70. Removing the expansion card from expansion card riser 3
Next steps
1Install the expansion card into the expansion card riser.
2 If you are removing the card permanently, install a metal ller bracket over the empty expansion slot opening and push the expansion
card latch.
NOTE: You must install a ller bracket over an empty expansion card slot to maintain Federal Communications
Commission (FCC) certication of the system. The brackets also keep dust and dirt out of the system and aid in
proper cooling and airow inside the system.
Installing and removing system components 127
Installing expansion card into the expansion card riser
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 If installing a new expansion card, unpack it and prepare the card for installation.
NOTE: For instructions, see the documentation accompanying the card.
3 When installing a card into riser 2 or 3, open the PCIe card holder latch.
Steps
1 Pull the expansion card latch.
2 If installed, remove the ller bracket.
NOTE: Store the ller bracket for future use. Filler brackets must be installed in empty expansion card slots to maintain
Federal Communications Commission (FCC) certication of the system. The brackets also keep dust and dirt out of the
system and aid in proper cooling and airow inside the system.
3 Hold the card by its edges, and align the card edge connector with the expansion card connector on the riser.
4 Insert the card edge connector rmly into the expansion card connector until the card is fully seated.
5 Push the expansion card latch.
Figure 71. Installing expansion card into expansion card riser 1
128 Installing and removing system components
Figure 72. Installing expansion card into expansion card riser 2B
Figure 73. Installing expansion card into expansion card riser 2
Installing and removing system components 129
Figure 74. Installing expansion card into expansion card riser 3
Next steps
1 If applicable, connect the cables to the expansion card.
2 If applicable, install the air shroud.
3 Follow the procedure listed in After working inside your system.
4 Install any device drivers required for the card as described in the documentation for the card.
Removing riser 2 and 3 blank
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
Steps
1 Using Phillips #2 screwdriver, loosen the screws (3) that secure the blank to the system.
2 Press the release tab, and holding the blank by its edges, lift the blank away from the system.
130 Installing and removing system components
Figure 75. Removing riser 2 and 3 blank
Next step
Install the riser 2 and 3 blank.
Installing riser 2 and 3 blank
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the screw and guide rail on the riser blank with the screw hole and stando on the system.
2 Lower the blank into the system until the release tab clicks into place.
3 Tighten the screws to secure the riser blank to the system.
Installing and removing system components 131
Figure 76. Installing riser 2 and 3 blank
Next steps
1Install the air shroud.
2 Follow the procedure listed in After working inside your system.
Removing riser 3 blank
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Using Phillips #2 screwdriver, loosen the screw that secures the blank to the system.
2 Lift the blank away from the system.
132 Installing and removing system components
Figure 77. Removing riser 3 blank
Next step
Install the riser 3 blank.
Installing riser 3 blank
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the screw on the riser with the screw hole on the system.
2 Using Phillips #2 screwdriver, tighten the screw to secure the blank to the system.
Installing and removing system components 133
Figure 78. Installing riser 3 blank
Next step
Follow the procedure listed in After working inside your system.
Removing expansion card riser 1
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If installed, remove the expansion cards from the riser.
4 Disconnect any cables connected to the riser.
Step
Press the release latches, and lift the riser from the riser connector on the system board.
134 Installing and removing system components
Figure 79. Removing expansion card riser 1
Next step
Install the expansion card riser 1.
Installing expansion card riser 1
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the guide rails on the riser with the standos on the side of the system.
2 Lower the riser into the system until the riser connector engages with the connector on the system board.
Installing and removing system components 135
Figure 80. Installing expansion card riser 1
Next steps
1 If removed, install expansion cards into the riser.
2 Follow the procedure listed in After working inside your system.
3 Install any device drivers required for the card as described in the documentation for the card.
Removing expansion card riser 2
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If applicable, close the PCIe card holder latch on the air shroud to release the full length card.
4 If installed, remove expansion cards installed on the riser.
5Remove the air shroud.
6 Disconnect any cables connected to the riser.
Steps
1 To remove expansion card riser 2A:
a Using Phillips #2 screwdriver, loosen the screws that secure the riser to the system.
b Press the release tab, and holding the riser by its edges, lift the riser from the riser connector on the system board.
136 Installing and removing system components
Figure 81. Removing expansion card riser 2A
2 To remove expansion card riser 2B or 2C, hold the riser by its edges and lift the riser from the riser connector on the system board.
Figure 82. Removing expansion card riser 2
Next step
Install the expansion card riser 2.
Installing expansion card riser 2
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 To install expansion card riser 2A:
a Align the screw and tab on the riser with the screw hole and slot on the system.
Installing and removing system components 137
b Lower the riser into the system until the riser connector engages with the connector on the system board.
c Using Phillips #2 screwdriver, tighten the screws to secure the riser to the system.
Figure 83. Installing expansion card riser 2A
2 To install expansion card riser 2B or 2C:
a Align the slot on the riser with the stando on the system.
b Lower the riser into the system until the riser card connector engages with the connector on the system board.
Figure 84. Installing expansion card riser 2
Next steps
1Install the air shroud.
2 If removed, install expansion cards into the riser.
3 If applicable, open the PCIe card holder latch on the air shroud to install the full length card.
4 Follow the procedure listed in After working inside your system.
5 Install any device drivers required for the card as described in the documentation for the card.
138 Installing and removing system components
Removing expansion card riser 3
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
NOTE: If applicable, close the PCIe card holder latch on the air shroud to release the full length card.
4 If installed, remove expansion cards installed on the riser.
5 Disconnect any cables connected to the riser card.
Steps
1 Using Phillips #2 screwdriver, loosen the screw that secures the riser to the system.
2 Press the release tab, and holding the riser by its edges, lift the riser from the riser connector on the system board.
Figure 85. Removing expansion card riser 3
Next step
Install expansion card riser 3.
Installing expansion card riser 3
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the tab on the riser with the slot on the system, and guide rails on the riser with the standos on the side of the system.
2 Lower the riser into the system until the riser edge connector engages with the connector on the system board.
The riser card edge engages with the riser guide on the system.
Installing and removing system components 139
3 Using Phillips #2 screwdriver, tighten the screw to secure the riser to the system.
Figure 86. Installing expansion card riser 3
Next steps
1 If removed, install expansion cards into the riser.
2Install the air shroud.
NOTE: If applicable, open the PCIe card holder latch on the air shroud to install the full length card.
3 Follow the procedure listed in After working inside your system.
4 Install any device drivers required for the card as described in the documentation for the card.
GPU card installation guidelines
• Ensure that both the processors are installed.
• The processor must use a GPU kit low-prole processor and heat sink module.
• To ensure adequate cooling when one or more GPUs are installed, the ambient inlet temperature is restricted to 30°C for CPU 150 W/8
C, 165 W/12 C, 200 W, 205 W. For more information, see the ambient temperature limitations section.
• Ensure that the GPU enablement kit is available.
The GPU enablement kit includes:
– GPU air shroud
– Mylar
– Riser 3A
– GPU cable for riser 3A
– GPU cable for riser 2A
– Riser 2A
– Riser 1A or 1D
– GPU cable for riser 1A or 1D
– Two 1U processor and heat sink modules and two CPU clips
140 Installing and removing system components
– Six high performance cooling fans
• All GPUs must be of the same type and model.
• You can install up to three double-wide or six single-wide GPUs.
• The ller bracket on the GPU air shroud must be removed before installing the GPU.
• Ensure that high performance fans and GPU air shroud are installed.
NOTE: When using systems with GPU, ensure that you install PSUs with 1100 W or higher, and set the PSU conguration to non-
redundant mode.
Removing a GPU
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Press the blue tabs on either sides of the shroud and remove the top cover of the GPU air shroud.
Figure 87. Removing the top cover of GPU air shroud
Steps
1 Lift the expansion card latch.
2 Close the PCIe card holder latch on the GPU air shroud.
3 Hold the GPU by its edges and slide out the GPU at an angle to release it from the connector on the riser.
Installing and removing system components 141
Figure 88. Removing GPU 1
Figure 89. Removing GPU 2 and 3
4 Disconnect the GPU power cable from the GPU and system board.
5 If you are removing the GPU permanently, install a ller bracket over the empty slot opening, and close the expansion card latch.
NOTE: You must install a ller bracket over an empty expansion card slot to maintain Federal Communications
Commission (FCC) certication of the system. The brackets also keep dust and dirt out of the system and aid in proper
cooling and airow inside the system. The ller bracket is necessary to maintain proper thermal conditions.
Next step
Install the GPU card.
142 Installing and removing system components
Installing a GPU
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2Remove the air shroud.
3Remove the heat sink.
4Remove the cooling fans and replace them with Install the cooling fans.
5 Unpack the GPU cards and the GPU kit.
6Install the heat sink from the kit.
7Install the risers.
8 Install the GPU air shroud on the system.
Figure 90. Installing GPU air shroud
9 Press the blue tabs on either sides of the shroud and remove the top cover of the shroud.
Installing and removing system components 143
Figure 91. Removing the top cover of the shroud
10 If applicable, remove the shroud ller from the GPU air shroud slots.
NOTE: Shroud llers are available in the GPU air shroud for GPUs installed on riser 2 and
3.
Figure 92. Removing the shroud ller from GPU air shroud slots
NOTE: Shroud llers are available in the GPU air shroud for GPUs installed only on risers 2 and
3.
NOTE: Ensure that the PCIe card holder latches on GPU air shroud and risers are closed before installing the GPU.
Full-length GPU do not require the PCIe card holder latch on the risers to secure the GPU in place.
144 Installing and removing system components
NOTE: Ensure that you install the rst GPU on riser
1.
NOTE: While installing a GPU on riser 3, place the GPU on the system with the GPU label side facing up.
Steps
1 Connect the GPU power cable to the connector on the system board.
NOTE:
While installing a GPU on riser 1, connect the GPU power cable to the connector on riser 1 and route the cable through the
slot on the GPU air shroud.
While installing a GPU on risers 2 or riser 3, connect the GPU power cable to the connector on the system board.
2 Connect the other end of the GPU power cable to the GPU.
3 Lift the expansion card latch and remove the ller bracket.
NOTE: You must install a ller bracket over an empty expansion card slot to maintain Federal Communications
Commission (FCC) certication of the system. The brackets also keep dust and dirt out of the system and aid in proper
cooling and airow inside the system.
NOTE: The ller bracket is necessary to maintain proper thermal conditions.
4 Align the connector on the GPU with the connector on the riser.
5 Insert the GPU into the riser until it is fully seated.
6 Press the PCIe lock on the GPU air shroud and riser to release the PCIe card holder latch.
NOTE: Ensure that the GPU edges are seated properly in the GPU air shroud slot and PCIe card holder latch to secure
the GPU in place.
7 Close the expansion card latch.
Figure 93. Installing GPU 1
Installing and removing system components 145
Figure 94. Securing GPU 1
146 Installing and removing system components
Figure 95. Installing GPU 2 and 3
Installing and removing system components 147
Figure 96. Securing GPU 2 and 3
Next steps
1 Install the top cover of the GPU air shroud.
If available, remove the plastic cover xed on the memory socket numbers marked on the air shroud.
Figure 97. Installing the top cover of GPU air shroud
2 To install mylar foam on the system cover:
a Place the system cover with the Service Information Label (SIL) side facing up.
148 Installing and removing system components
b For easier handling, peel o a small section of the adhesive cover and align the mylar foam with the system cover.
c Remove rest of the adhesive cover and install mylar foam on the system cover.
d Press along the length of the mylar foam to ensure that it is rmly axed to the system cover.
Figure 98. Installing mylar foam on the system cover
3 Follow the procedure listed in After working inside your system.
M.2 SSD module
Removing the M.2 SSD module
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
4 Remove the BOSS card.
NOTE: Removing the BOSS card is similar to the procedure for removing an expansion card riser.
Steps
1 Loosen the screws and lift the retention straps that secure the M.2 SSD module on the BOSS card.
2 Pull the M.2 SSD module away from the BOSS card.
Installing and removing system components 149
Figure 99. Removing the M.2 SSD module
Next step
Install the M.2 SSD module.
Installing the M.2 SSD module
Prerequisite
1 Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the M.2 SSD module connectors with the connectors on the BOSS card.
2 Push the M.2 SSD module until the module is seated rmly on the BOSS card.
3 Secure the M.2 SSD module on the BOSS card with the retention straps and screws.
150 Installing and removing system components
Figure 100. Installing the M.2 SSD module
Next steps
1 Install the BOSS card.
NOTE: Installing the BOSS card is similar to installing the expansion card riser.
2Install the air shroud .
3 Follow the procedure listed in After working inside your system.
Optional IDSDM or vFlash module
Removing the MicroSD and vFlash card
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Locate the MicroSD card slot on the vFlash/IDSDM module, and press the card to partially release it from the slot.
To locate IDSDM/vFlash module, see the System board jumpers and connectors section.
2 Hold the MicroSD card and remove it from the slot.
NOTE: Temporarily label each MicroSD card with its corresponding slot number after removal.
Installing and removing system components 151
Next step
Install the MicroSD card.
Installing the MicroSD and vFlash card
Prerequisites
Follow the safety guidelines listed in Safety instructions.
NOTE: To use an MicroSD card with your system, ensure that the Internal SD Card Port is enabled in System Setup.
NOTE: If reinstalling, ensure that you install the MicroSD cards into the same slots based on the labels you had marked on the
cards during removal.
Steps
1 Locate the MicroSD card connector on the IDSDM/vFlash module. Orient the MicroSD card appropriately and insert the contact-pin
end of the card into the slot.
To locate IDSDM/vFlash, see the System board jumpers and connectors section.
NOTE: The slot is keyed to ensure correct insertion of the card.
2 Press the card into the card slot to lock it into place.
152 Installing and removing system components
Next step
Follow the procedure listed in After working inside your system.
Removing the optional IDSDM or vFlash module
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If applicable, remove the full-height PCIe cards.
4 If you are replacing the IDSDM/vFlash card, remove the MicroSD cards.
NOTE: Temporarily label each MicroSD card with its corresponding slot number after removal.
Steps
1 Locate the IDSDM/vFlash connector on the system board.
To locate IDSDM/vFlash connector, see the System board jumpers and connectors section.
2 Holding the pull tab, lift the IDSDM/vFlash card out of the system.
Installing and removing system components 153
Figure 101. Removing the optional IDSDM/vFlash module
NOTE: There are two dip switches on the IDSDM/vFlash card for write-protection.
Next step
Install the optional IDSDM/vFlash module.
Installing optional IDSDM or vFlash card
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Locate the IDSDM/vFlash connector on the system board.
To locate IDSDM/vFlash connector, see the System board jumpers and connectors section.
2 Align the IDSDM/vFlash card with the connector on the system board.
3 Push the IDSDM/vFlash card until it is rmly seated on the system board.
154 Installing and removing system components
Figure 102. Installing optional IDSDM/vFlash card
Next steps
1Install the MicroSD cards.
NOTE: Reinstall the MicroSD cards into the same slots based on the labels you had marked on the cards during
removal.
2 If applicable, install the full height PCIe card.
3 Follow the procedure listed in After working inside your system.
Network daughter card
Removing the network daughter card
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If applicable, remove the expansion card riser 2.
Steps
1 Using a Phillips #2 screwdriver, loosen the captive screws that secure the network daughter card (NDC) to the system board.
2 Hold the NDC by the edges on either side of the touch points, and lift to remove it from the connector on the system board.
3 Slide the NDC towards the front of the system until the Ethernet connectors are clear of the slot in the back panel.
Installing and removing system components 155
Figure 103. Removing network daughter card
Next step
Install the Network Daughter Card.
Installing the network daughter card
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Orient the NDC so that the Ethernet connectors t through the slot in the chassis.
2 Align the captive screws at the back-end of the card with the screw holes on the system board.
3 Press the touch points on the card until the card connector is rmly seated on the system board connector.
4 Using a Phillips #2 screwdriver, tighten the captive screws to secure the NDC to the system board.
156 Installing and removing system components
Figure 104. Installing the network daughter card
Next steps
1 If applicable, install the expansion card riser 2.
2 Follow the procedure listed in After working inside your system.
Integrated storage controller card
Removing integrated storage controller card
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
4Remove the expansion card riser 1.
Steps
1 Using Phillips #2 screwdriver, loosen the screws that secure the integrated storage controller cable to the system board.
2 Lift the integrated storage controller cable away from the integrated storage controller.
Installing and removing system components 157
Figure 105. Removing integrated storage controller cable
3 Lift one end of the card and angle it to disengage the card from the integrated storage controller card holder on the system board.
4 Lift the card out of the system.
5 Hold the interposer board by its edges, and pull the board until the connector on the board disengages from the connector on the
system board.
Figure 106. Removing integrated storage controller card
Next step
Install the integrated storage controller card.
Installing integrated storage controller card
Prerequisite
Follow the safety guidelines listed in Safety instructions.
158 Installing and removing system components
Steps
1 Hold the interposer board by its edges, and align the interposer board connector with the connector on the system board.
2 Press the touch point on the interposer board until the interposer board connector is rmly seated on the system board connector.
3 Angle the card to engage the card with the integrated storage controller card holder on the system board.
4 Lower the card into place until the card is fully seated in the integrated storage controller card holder.
Figure 107. Installing integrated storage controller card
5 Align the screws on the integrated storage controller card cable with the screw holes on the system board.
6 Using Phillips #2 screwdriver, tighten the screws to secure the integrated storage controller card cable to the system board.
Figure 108. Installing integrated storage controller card cable
Next steps
1Install the expansion card riser 1.
2Install the air shroud.
3 Follow the procedure listed in After working inside your system.
Installing and removing system components 159
Backplane
Backplane details
Depending on your system conguration, the backplanes supported in PowerEdge R740 are listed here:
Table 51. Supported backplane options for PowerEdge R740 systems.
System Supported backplane options
PowerEdge R740
2.5 inch (x16) SAS/SATA backplane, or
2.5 inch (x8) SAS/SATA backplane, or
3.5 inch (x8) SAS/SATA backplane
Figure 109. Back view of 16 x 2.5 inch drive backplane
1signal connector (J_BP_SIG) 2 power connector (J_BP_PWR)
Figure 110. Back view of 8 x 2.5 inch drive backplane
1SAS connector (BP SAS B) 2 SAS connector (BP SAS A)
3 power connector (J_BP_PWR) 4 signal connector (J_BP_SIG)
160 Installing and removing system components
Figure 111. Back view of 8 x 3.5 inch drive backplane
1 SAS connector (BP SAS B) 2 signal connector (J_BP_SIG)
3 SAS connector (BP SAS A) 4 power connector (J_BP_PWR_A)
Removing the backplane
The procedure to remove the backplane is identical for all backplane congurations.
Prerequisites
CAUTION: To prevent damage to the drives and backplane, remove the drives from the system before removing the backplane.
CAUTION: Note the number of each drive and temporarily label them before you remove the drive so that you can replace them
in the same locations.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
4Remove the cooling fan assembly.
5Remove the backplane cover.
6Remove all drives.
7 Disconnect all the cables from the backplane.
Step
Press the release tabs and lift the backplane to disengage the backplane from the hooks on the system.
Installing and removing system components 161
Figure 112. Removing the backplane
Next step
Install the backplane.
Installing the backplane
The procedure to install the backplane is identical for all backplane congurations.
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Use the hooks on the system as guides to align the backplane.
2 Lower the backplane until the release tabs snap into place.
Figure 113. Installing the backplane
162 Installing and removing system components
Next steps
1 Connect all the cables to the backplane.
2Install all the drives.
3Install the backplane cover.
4Install the cooling fan assembly.
5Install the air shroud.
6 Follow the procedure listed in After working inside your system.
Cable routing
Figure 114. Cable routing – 8 x 2.5 inch drive backplane with mini PERC
1backplane 2 backplane power cable (BP: BP1 to MB: BP1 )
3 backplane signal cable (BP: BPSIG1 to MB: BPSIG1) 4 system board
5 mini PERC 6 SAS cable (BP: BP SAS A, BP SAS B to adapter PERC)
Installing and removing system components 163
Figure 115. Cable routing – 8 x 2.5 inch drive backplane with adapter PERC
1backplane 2 backplane signal cable (BP: BPSIG1 to MB: BPSIG1)
3 backplane power cable (BP: BP1 to MB: BP1) 4 system board
5 adapter PERC 6 SAS cable (BP: BP SAS A, BP SAS B to MB: RISER 2)
164 Installing and removing system components
Figure 116. Cable routing – 8 x 3.5 inch drive backplane with on board SATA
1backplane 2 backplane power cable (BP: BP1 to MB: BP1)
3 backplane signal cable (BP: BPSIG1 to MB: BPSIG1) 4 system board
5 SATA B cable (BP: BP SAS B to MB: J_BP_SIG1) 6 SATA A cable (BP: BP SAS A to MB: BP 12C RVYPM)
Installing and removing system components 165
Figure 117. Cable routing – 8 x 3.5 inch drive backplane with mini PERC
1backplane 2 backplane power cable (BP: BP to MB: BP1)
3 backplane signal cable (BP: BPSIG1 to MB: BPSIG1) 4 system board
5 mini PERC 6 SAS cable (BP: BP SAS A0, BP SAS B0 to MB:
J_STORAGE1)
166 Installing and removing system components
Figure 118. Cable routing – 8 x 3.5 inch drive backplane with adapter PERC
1backplane 2 backplane power cable (BP: BP1 to MB: BP1)
3 backplane signal cable (BP: BPSIG1 to MB: BPSIG1) 4 system board
5 adapter PERC 6 SAS A cable (BP: BP SAS A0 to MB: J_BP_PWR_A1)
7 SAS B cable (BP: BP SAS B0 to MB: J_BP_SIG1)
Installing and removing system components 167
Figure 119. Cable routing – 16 x 2.5 inch drive backplane with mini PERC
1backplane 2 backplane expander
3 backplane power cable (BP: BP1 to MB: BP1) 4 backplane signal cable (BP: BPSIG1 to MB: BPSIG1)
5 system board 6 mini PERC
7 SAS cable (BP: BP SAS A0, BP SAS BO to MB: J_STORAGE1)
168 Installing and removing system components
Figure 120. Cable routing – 16 x 2.5 inch drive backplane with adapter PERC
1backplane 2 backplane expander
3 backplane power cable (BP: BP1 to MB: BP1) 4 backplane signal cable (BP: BPSIG1 to MB: BPSIG1)
5 system board 6 adapter PERC
7 SAS cable (BP: J_SAS_BO, J_SAS_A0 to MB: J_STORAGE1)
System battery
Replacing the system battery
Prerequisites
WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or
equivalent type recommended by the manufacturer. For more information, see the safety information that shipped with your
system.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If applicable, close the PCIe card holder latch on the air shroud to release the full length card.
4 If applicable, disconnect the power or data cables from expansion card(s).
5Remove the expansion card riser 1A.
Steps
1 Locate the battery socket. For more information, see the System board jumpers and connectors section.
Installing and removing system components 169
CAUTION: To avoid damage to the battery connector, you must rmly support the connector while installing or
removing a battery.
2 Use a plastic scribe to pry out the system battery.
Figure 121. Removing the system battery
3 To install a new system battery, hold the battery with the positive side facing up and slide it under the securing tabs.
4 Press the battery into the connector until it snaps into place.
Figure 122. Installing the system battery
Next steps
1Install the expansion card riser 1A.
2 If applicable, connect the cables to the expansion card(s).
3 If applicable, open the PCIe card holder latch on the air shroud to secure the full length expansion card.
4 Follow the procedure listed in After working inside your system.
5 While booting, press F2 to enter the System Setup and ensure that the battery is operating properly.
6 Enter the correct time and date in the System Setup Time and Date elds.
7 Exit the System Setup.
USB 3.0 module
USB 3.0 module details
An additional USB 3.0 port can be added to the front of the system. The USB 3.0 module cable connects to the internal USB port on the
system board. In this scenario, the default internal USB port is available under the backplane cover.
NOTE: The position of the USB 3.0 module and default internal USB port may vary depending on the conguration of your
system.
170 Installing and removing system components
Removing USB 3.0 module
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the backplane cover.
4Remove the cooling fan assembly.
5Remove the air shroud.
6Remove the internal USB memory key.
NOTE: The position of the USB 3.0 module may vary depending on the conguration of your
system.
NOTE: Ensure that you note the routing of the cables as you remove them from the system board. Route these cables
properly when you replace them to prevent them from being pinched or crimped.
Steps
1 Disconnect the cables from the system board.
2 Using Phillips #2 screwdriver, loosen the screw on the USB 3.0 module.
3 Slide the USB 3.0 module out of the system.
Figure 123. Removing USB 3.0 module
Next step
Install the USB 3.0 module.
Installing USB 3.0 module
Prerequisite
Follow the safety guidelines listed in Safety instructions.
NOTE: The position of the USB 3.0 module may vary depending on the conguration of your system.
Installing and removing system components 171
Steps
1 Route the power and the USB cables on the USB 3.0 module through the USB 3.0 module slot on the front panel.
2 Insert the USB 3.0 module into the slot on the front panel.
3 Align the screws on the module with the screw holes on the system.
4 Using the Phillips #2 screwdriver, tighten the screw to secure the module to the system.
5 Route and connect the USB cable to internal USB port and power cable to the backplane 3 power connector on the system board.
To locate the connector, see the System board jumpers and connectors section.
Figure 124. Installing USB 3.0 module
Next steps
1Install the internal USB memory key.
2Install the air shroud.
3Install the cooling fan assembly.
4Install the backplane cover.
5 Follow the procedure listed in After working inside your system.
Optional internal USB memory key
Optional internal USB memory key details
An optional USB memory key can be installed in the internal USB 3.0 port.
NOTE: To locate the internal USB port on the system board, see the System board jumpers and connectors section.
For congurations that support USB 3.0 module, the USB 3.0 module cable connects to the internal USB port on the system board. In this
scenario, the default internal USB port is available under the backplane cover. The position of the default internal USB port may vary
depending on the conguration of your system.
172 Installing and removing system components
Replacing the optional internal USB memory key
Prerequisites
CAUTION: To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory
key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Locate the USB port or USB memory key on the system board.
To locate the USB port, see the internal USB memory key details section.
2 If installed, remove the USB memory key from the USB port.
3 Insert the replacement USB memory key into the USB port.
Next steps
1 Follow the procedure listed in After working inside your system.
2 While booting, press F2 to enter System Setup and verify that the system detects the USB memory key.
Optional optical drive
Removing the optional optical drive
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the backplane cover.
4Remove the air shroud.
5 Disconnect the power and data cables from the back of the drive.
NOTE: Ensure that you note the routing of the power and data cable on the side of the system as you remove them
from the system board and drive. Route these cables properly when you replace them to prevent them from being
pinched or crimped.
Steps
1 Press the release tab to release the optical drive.
2 Slide the optical drive out of the system.
Installing and removing system components 173
Figure 125. Removing the optional optical drive
Next steps
1 If you are not adding a new optical drive, install the optical drive blank.
The procedure to install the optical drive blank is the same as the optical drive.
2Install the optional optical drive.
Installing the optional optical drive
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the optical drive with the optical drive slot on the front of the system.
2 Slide in the optical drive until the release tab snaps into place.
174 Installing and removing system components
Figure 126. Installing the optional optical drive
Next steps
1 Connect the power and data cables to the optical drive and system board.
NOTE: Route the cable properly on the side of the system to prevent it from being pinched or crimped.
2Install the air shroud.
3Install the backplane cover.
4 Follow the procedure listed in After working inside your system.
Power supply units
Power supply unit details
Your system supports one of the following:
• Two 2400 W, 2000 W, 1600 W, 1100 W, 750 W, or 495 W AC PSUs
• Two 1100 W DC PSUs
• Two 1100 W or 750 W Mixed Mode HVDC PSUs
NOTE: For more information, see the Technical specications section.
CAUTION: If two PSUs are installed, both the PSUs must have the same type of label. For example, Extended Power
Performance (EPP) label. Mixing PSUs from previous generations of PowerEdge servers is not supported, even if the PSUs have
the same power rating. Mixing PSUs will result in mismatch condition or failure to turn the system on.
NOTE: Titanium PSU is nominally rated for 200 V AC to 240 V AC input only.
Installing and removing system components 175
NOTE: When two identical PSUs are installed, power supply redundancy (1+1 – with redundancy or 2+0 – without redundancy) is
congured in system BIOS. In redundant mode, power is supplied to the system equally from both PSUs when Hot Spare is
disabled. When Hot Spare is enabled, one of the PSUs is put into the sleep mode when system utilization is low in order to
maximize eciency.
NOTE: If two PSUs are used, they must be of the same maximum output power.
Hot spare feature
Your system supports the hot spare feature that signicantly reduces the power overhead associated with power supply unit (PSU)
redundancy.
When the hot spare feature is enabled, one of the redundant PSUs is switched to the sleep state. The active PSU supports 100 percent of
the system load, thus operating at higher eciency. The PSU in the sleep state monitors output voltage of the active PSU. If the output
voltage of the active PSU drops, the PSU in the sleep state returns to an active output state.
If having both PSUs active is more ecient than having one PSU in the sleep state, the active PSU can also activate the sleeping PSU.
The default PSU settings are as follows:
• If the load on the active PSU is more than 50 percent of PSU rated power wattage, then the redundant PSU is switched to the active
state.
• If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to the sleep
state.
You can congure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC User’s Guide available at
www.dell.com/poweredgemanuals.
Removing a power supply unit blank
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Step
If you are installing a second power supply unit (PSU), remove the PSU blank in the bay by pulling the blank outward.
CAUTION: To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a non-redundant
conguration. Remove the PSU blank only if you are installing a second PSU.
Figure 127. Removing a power supply unit blank
Next step
Install the PSU blank.
176 Installing and removing system components
Installing a power supply unit blank
Prerequisite
1 Follow the safety guidelines listed in Safety instructions.
NOTE: Install the power supply unit (PSU) blank only in the second PSU bay.
Step
Align the PSU blank with the PSU slot and push it into the PSU slot until it clicks into place.
Figure 128. Installing a power supply unit blank
Removing a power supply unit
The procedure for removing AC and DC PSUs is identical.
Prerequisites
CAUTION: The system needs one power supply unit (PSU) for normal operation. On power-redundant systems, remove and
replace only one PSU at a time in a system that is powered on.
1 Follow the safety guidelines listed in Safety instructions.
2 Disconnect the power cable from the power source and from the PSU you intend to remove, and then remove the cable from the
strap on the PSU handle.
3 Unlatch and lift the optional cable management arm if it interferes with the PSU removal.
For information about the cable management arm, see the system’s rack documentation at www.dell.com/poweredgemanuals.
Step
Press the orange release latch and slide the PSU out of the system by using the PSU handle.
Installing and removing system components 177
Figure 129. Removing a power supply unit
Next step
Install the PSU or PSU blank.
Installing a power supply unit
The procedure for installing AC and DC PSUs is identical.
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 For systems that support redundant PSU, ensure that both the PSUs are of the same type and have the same maximum output
power.
NOTE: The maximum output power (shown in watts) is listed on the PSU label.
Step
Slide the PSU into the system until the PSU is fully seated and the release latch snaps into place.
178 Installing and removing system components
Figure 130. Installing a power supply unit
Next steps
1 If you have unlatched the cable management arm, relatch it. For information about the cable management arm, see the system’s rack
documentation at www.dell.com/poweredgemanuals.
2 Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION: When connecting the power cable to the PSU, secure the cable to the PSU with the strap.
NOTE: When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds for the system to recognize the
PSU and determine its status. The PSU redundancy may not occur until discovery is complete. Wait until the new PSU
is discovered and enabled before you remove the other PSU. The PSU status indicator turns green to signify that the
PSU is functioning properly.
Wiring instructions for a DC power supply unit
Your system supports up to two –(48–60) V DC power supply units (PSUs).
WARNING: For equipment using –(48–60) V DC power supply units (PSUs), a qualied electrician must perform all connections
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring
must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
CAUTION: Wire the unit with copper only, unless otherwise specied, use only 10 American Wire Gauge (AWG) wire rated
minimum 90ºC for source and return. Protect the –(48–60) V DC (1 wire) with a branch circuit over-current protection rated 50
A for DC with a high interrupt current rating.
CAUTION: Connect the equipment to a –(48–60) V DC supply source that is electrically isolated from the AC source (reliably
grounded –(48–60) V DC SELV source). Ensure that the –(48–60) V DC source is eciently secured to earth (ground).
NOTE: A readily accessible disconnect device that is suitably approved and rated shall be incorporated in the eld wiring.
Input requirements
• Supply voltage: –(48–60) V DC
Installing and removing system components 179
• Current consumption: 32 A (maximum)
Kit contents
• Dell part number 6RYJ9 terminal block or equivalent (1)
• #6-32 nut equipped with lock washer (1)
Required tools
Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire.
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding).
Required wires
• One UL 10 AWG, 2 m maximum (stranded) black wire [–(48–60) V DC].
• One UL 10 AWG, 2 m maximum (stranded) red wire (V DC return).
• One UL 10 AWG, 2 m maximum, green with a yellow stripe, stranded wire (safety ground).
Assembling and connecting safety ground wire
Prerequisite
WARNING: For equipment using –(48–60) V DC power supply units (PSUs), a qualied electrician must perform all connections
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring
must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
Steps
1 Strip the insulation from the end of the green or yellow wire, exposing approximately 4.5 mm (0.175 inch) of copper wire.
2 Using a hand-crimping tool (Tyco Electronics, 58433-3 or equivalent), crimp the ring-tongue terminal (Jeeson Terminals Inc., R5-4SA
or equivalent) to the green and yellow wire (safety ground wire).
3 Connect the safety ground wire to the grounding post on the back of the system by using a #6-32 nut equipped with a locking
washer.
Assembling DC input power wires
Prerequisite
WARNING: For equipment using –(48–60) V DC power supply units (PSUs), a qualied electrician must perform all connections
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring
must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
Steps
1 Strip the insulation from the ends of the DC power wires, exposing approximately 13 mm (0.5 inch) of copper wire.
WARNING: Reversing polarity when connecting DC power wires can permanently damage the power supply or the
system.
2 Insert the copper ends into the mating connectors and tighten the captive screws at the top of the mating connector using a Phillips
#2 screwdriver.
180 Installing and removing system components
WARNING: To protect the power supply from electrostatic discharge, the captive screws must be covered with the
rubber cap before inserting the mating connector into the power supply.
3 Rotate the rubber cap clockwise to x it over the captive screws.
4 Insert the mating connector into the power supply.
System board
Removing system board
Prerequisites
CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted to create a
recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you replace this system
board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on
your drives.
CAUTION: Do not attempt to remove the TPM plug-in module from the system board. Once the TPM plug-in module is installed,
it is cryptographically bound to that specic system board. Any attempt to remove an installed TPM plug-in module breaks the
cryptographic binding, and it cannot be re-installed or installed on another system board.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Remove the following:
aAir shroud
bCooling fan assembly
cPower supply units
dExpansion cards and expansion card risers
eIntegrated storage controller card
fOptional IDSDM or vFlash card
gOptional internal USB memory key (if installed)
hUSB 3.0 module (if installed)
iProcessor and heat sink module
j Processor blank (if installed)
CAUTION: To prevent damage to the processor socket when replacing a faulty system board, ensure that
you cover the processor socket with the processor dust cover.
kMemory modules and memory module blanks
lNetwork daughter card
Steps
1 Disconnect all cables from the system board.
CAUTION: Take care not to damage the system identication button while removing the system board from the system.
CAUTION: Do not lift the system board by holding a memory module, processor, or other components.
2 Holding the system board holder, pull the blue release pin, and slide the system board toward the front of the system to disengage the
connectors from the slots on the system.
3 Incline the system board at an angle, and lift the system board out of the system.
Installing and removing system components 181
Figure 131. Removing system board
Next step
Install the system board.
Installing system board
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Unpack the replacement system board assembly.
CAUTION: Do not lift the system board by holding a memory module, processor, or other components.
CAUTION: Take care not to damage the system identication button while placing the system board into the system.
2 Holding the system board holder and blue release pin, incline the system board, and lower the system board into the system.
3 Slide the system board toward the back of the system until the release pin clicks into place.
182 Installing and removing system components
Figure 132. Installing system board
Next steps
1 Replace the following:
aTrusted Platform Module
NOTE: The TPM plug-in module is attached to the system board and cannot be removed. A replacement
TPM plug-in module will be provided for all system board replacements where a TPM plug-in module was
installed.
bIntegrated storage controller card
cOptional internal USB memory key (if applicable)
dUSB 3.0 module (if applicable)
eOptional IDSDM or vFlash module
fExpansion cards and expansion card risers
gProcessor and heat sink module
h Processor blank (if applicable)
iMemory modules and memory module blanks
jNetwork daughter card
kCooling fan assembly
lAir shroud
mPower supply units
2 Reconnect all cables to the system board.
NOTE: Ensure that the cables inside the system are routed along the chassis wall and secured using the cable securing
bracket.
3 Follow the procedure listed in After working inside your system.
4 Ensure that you:
a Use the Easy Restore feature to restore the Service Tag. For more information, see Restoring the Service Tag using Easy
Restore.
b If the Service Tag is not backed up in the backup ash device, enter the Service Tag manually. For more information, see
Entering the system Service Tag by using System Setup.
c Update the BIOS and iDRAC versions.
d Re-enable the Trusted Platform Module (TPM). For more information, see Upgrading the Trusted Platform Module.
5 Import your new or existing iDRAC Enterprise license.
For more information, see Integrated Dell Remote Access Controller User's Guide, at www.dell.com/poweredgemanuals.
Installing and removing system components 183
Restoring the Service Tag using Easy Restore
The easy restore feature allows you to restore your service tag, license, UEFI conguration, and the system conguration data after
replacing the system board. All data is backed up in a backup ash device automatically. If BIOS detects a new system board, and the
service tag in the backup ash device, BIOS prompts the user to restore the backup information.
Below is a list of options available:
• Restore the service tag, license, and diagnostics information, press Y
• Navigate to the Lifecycle Controller based restore options, press N.
• Restore data from a previously created Hardware Server Prole, press F10
NOTE: When the restore process is complete, BIOS prompts to restore the system conguration
data.
• To restore the system conguration data, press Y
• To use the default conguration settings, press N
NOTE: After the restore process is complete, system reboots.
Manually update the Service Tag
After replacing a system board, if Easy Restore fails, follow this process to manually enter the Service Tag, using System Setup.
About this task
If you know the system service tag, use the System Setup menu to enter the service tag.
Steps
1 Turn on the system.
2 To enter the System Setup, press F2.
3 Click Service Tag Settings.
4 Enter the service tag.
NOTE: You can enter the service tag only when the Service Tag eld is empty. Ensure that you enter the correct service
tag. Once the service tag is entered, it cannot be updated or changed.
5 Click OK.
Entering the system Service Tag by using System Setup
If Easy Restore fails to restore the Service Tag, use System Setup to enter the Service Tag.
1 Turn on the system.
2 Press F2 to enter System Setup.
3 Click Service Tag Settings.
4 Enter the Service Tag.
NOTE: You can enter the Service Tag only when the Service Tag eld is empty. Ensure that you enter the correct
Service Tag. After the Service Tag is entered, it cannot be updated or changed.
5 Click OK.
6 Import your new or existing iDRAC Enterprise license.
For more information, see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals.
Trusted Platform Module
184 Installing and removing system components
Upgrading the Trusted Platform Module
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
NOTE:
• Ensure that your operating system supports the version of the TPM module being installed.
• Ensure that you download and install the latest BIOS rmware on your system.
• Ensure that the BIOS is congured to enable UEFI boot mode.
About this task
CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted to create a
recovery key during program or System Setup. Work with the customer to create and safely store this recovery key. When
replacing this system board, you must supply the recovery key when you restart your system or program before you can access
the encrypted data on your hard drives.
CAUTION: Once the TPM plug-in module is installed, it is cryptographically bound to that specic system board. Any attempt to
remove an installed TPM plug-in module breaks the cryptographic binding, the removed TPM cannot be reinstalled or installed on
another system board.
Removing the TPM
1 Locate the TPM connector on the system board.
2 Press to hold the module down and remove the screw using the security Torx 8-bit shipped with the TPM module.
3 Slide the TPM module out from its connector.
4 Push the plastic rivet away from the TPM connector and rotate it 90° counterclockwise to release it from the system board.
5 Pull the plastic rivet out of its slot on the system board.
Installing the TPM
Steps
1 To install the TPM, align the edge connectors on the TPM with the slot on the TPM connector.
2 Insert the TPM into the TPM connector such that the plastic rivet aligns with the slot on the system board.
3 Press the plastic rivet until the rivet snaps into place.
Installing and removing system components 185
Figure 133. Installing the TPM
4 Replace the screw that secures the TPM to the system board.
Next steps
1Install the system board.
2 Follow the procedure listed in After working inside your system.
Initializing TPM for BitLocker users
Initialize the TPM.
For more information, see .
The TPM Status changes to Enabled, Activated.
Initializing the TPM 1.2 for TXT users
1 While booting your system, press F2 to enter System Setup.
2 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
3 From the TPM Security option, select On with Pre-boot Measurements.
4 From the TPM Command option, select Activate.
5 Save the settings.
6 Restart your system.
7 Enter System Setup again.
8 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
9 From the Intel TXT option, select On.
Initializing the TPM 2.0 for TXT users
1 While booting your system, press F2 to enter System Setup.
2 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
3 From the TPM Security option, select On.
4 Save the settings.
5 Restart your system.
6 Enter System Setup again.
186 Installing and removing system components
7 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
8 Select the TPM Advanced Settings option.
9 From the TPM2 Algorithm Selection option, select SHA256, then go back to System Security Settings screen.
10 On the System Security Settings screen, from the Intel TXT option, select On.
11 Save the settings.
12 Restart your system.
Control panel
Control panel details
Your system supports:
• Left control panel: Contains status LEDs, system ID button, and iDRAC Quick Sync 2 (optional).
• Right control panel: Contains power button, USB 2.0 port, VGA port micro USB for iDRAC Direct, and status LED for iDRAC Direct.
Removing the left control panel
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the cooling fan assembly.
4Remove the air shroud
Steps
1 Pull the cable latch and disconnect the control panel cable from the system board connector.
2 Using a Phillips #1 screwdriver, remove the screws to remove the cable cover, which secure the lest control panel and cable tube to
the system.
3 Holding the control panel and cable tube by its sides, remove the control panel and cable tube away from the system.
Installing and removing system components 187
Figure 134. Removing left control panel
Next step
Install the left control panel.
Installing the left control panel
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Route the control panel cable through the side wall of the system.
2 Align the left control panel assembly with the control panel slot on the system and place the assembly in the slot on the system.
3 Connect the control panel cable to the system board connector and secure it using cable latch.
4 Using a Phillips #1 screwdriver, install the screws that secure the control panel and cable tube to the system.
188 Installing and removing system components
Figure 135. Installing left control panel
Next steps
1Install the air shroud.
2Install the cooling fan assembly.
3 Follow the procedure listed in After working inside your system.
Removing the right control panel
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
4Remove the cooling fan assembly.
Steps
1 Disconnect the VGA cable from the system board.
2 Pull the cable latch and disconnect the control panel cable from the system board connector.
3 Using Phillips #1 screwdriver, remove the screws that secure the control panel and cable tube to the system.
4 Holding the control panel and cable tube by its sides, remove the control panel and cable tube away from the system.
Installing and removing system components 189
Figure 136. Removing right control panel
Next step
Install the right control panel.
Installing the right control panel
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Route the control panel cable and VGA cable through the side wall of the system.
2 Align the control panel with the control panel slot on the system and attach the control panel to the system.
3 Connect the VGA cable to the system board.
4 Connect the control panel cable to the connector on the system board and lower the cable latch to secure the cable in place.
5 Using a Phillips #1 screwdriver, install the screw that secures the control panel and cable tube to the system.
190 Installing and removing system components
Using system diagnostics
If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of
running system diagnostics is to test your system hardware without using additional equipment or risking data loss. If you are unable to x
the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.
Dell Embedded System Diagnostics
NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics.
The Embedded System Diagnostics provides a set of options for particular device groups or devices allowing you to:
• Run tests automatically or in an interactive mode
• Repeat tests
• Display or save test results
• Run thorough tests to introduce additional test options to provide extra information about the failed device(s)
• View status messages that inform you if tests are completed successfully
• View error messages that inform you of problems encountered during testing
Running the Embedded System Diagnostics from Boot
Manager
Run the Embedded System Diagnostics (ePSA) if your system does not boot.
1 When the system is booting, press F11.
2 Use the up arrow and down arrow keys to select System Utilities > Launch Diagnostics.
3 Alternatively, when the system is booting, press F10, select Hardware Diagnostics > Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts
executing the tests on all the detected devices.
Running the Embedded System Diagnostics from the Dell
Lifecycle Controller
1 As the system boots, press F10.
2 Select Hardware Diagnostics → Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts
executing the tests on all the detected devices.
7
192 Using system diagnostics
System diagnostic controls
Menu Description
Conguration Displays the conguration and status information of all detected devices.
Results Displays the results of all tests that are run.
System health Provides the current overview of the system performance.
Event log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event
description is recorded.
Using system diagnostics 193
Jumpers and connectors
This topic provides specic information about the jumpers. It also provides some basic information about jumpers and switches and
describes the connectors on the various boards in the system. Jumpers on the system board help to disable the system and setup
passwords. You must know the connectors on the system board to install components and cables correctly.
Topics:
• System board jumpers and connectors
• System board jumper settings
• Disabling forgotten password
8
194 Jumpers and connectors
System board jumpers and connectors
Figure 138. System board jumpers and connectors
Table 52. System board jumpers and connectors
Item Connector Description
1 J_ODD Optical drive power connector
2 A7, A1, A8, A2, A9, A3 Memory module sockets
3 J_FAN2U_6 Cooling fan 6 connector
4 J_BP3 Backplane 3 power connector
5 J_FAN2U_5 Cooling fan 5 connector
6 A6, A12, A5, A11, A4, A10 Memory module sockets
7 J_FAN2U_4 Cooling fan 4 connector
Jumpers and connectors 195
Item Connector Description
8 INTRUSION_DET Intrusion switch connector
9 B7, B1, B8, B2, B9, B3 Memory module sockets
10 J_FAN2U_3 Cooling fan 3 connector
11 J_FAN2U_2 Cooling fan 2 connector
12 J_BP_SIG1 Backplane 1 signal connector
13 B6, B12, B5, B11, B4, B10 Memory module sockets
14 J_BP1 Backplane 1 power connector
15 J_FAN2U_1 Cooling fan 1 connector
16 P_LFT_CP Left control panel connector
17 CPU2 CPU2 processor and heat sink module socket (with dust
cover)
18 J_R3_X24 Riser 3 connector
19 J_BP_SIG2 Backplane 2 signal connector
20 J_BP_SIG0 Backplane 0 signal connector
21 J_BP0 (RSR3_225W) Backplane 0 power connector (Riser 3 PCIe 225 W power)
22 J_BP2 (RSR2_225W) Backplane 2 power connector (Riser 2 PCIe 225 W power)
23 J_BATT_SIG NVDIMM-N battery signal connector
24 J_BATT_PWR NVDIMM-N battery power connector
25 PWRD_EN Reset BIOS password
26 NVRAM_CLR Clear NVRAM
27 J_USB_INT Internal USB connector
28 J_IDSDM IDSDM/vFlash connector
29 J_NDC NDC connector
30 J_R2_X24_IT9 Riser 2 connector
31 J_R2_3R_X8_IT9 Riser 2 connector
32 LEDs System board diagnostic LED indicators
33 BATTERY Battery connector
34 J_FRONT_VIDEO Video connector
35 J_R1_SS82_3 and J_R1_SS60_1 Riser 1 connector
36 J_TPM_MODULE TPM connector
37 J_SATA_B SATA B connector
38 J_R1_SS82_1 Riser 1 connector (Mini PERC option)
39 J_SATA_A SATA A connector
40 J_SATA_C SATA C connector (Optical drive SATA connector)
41 CPU1 CPU1 processor and heat sink module
42 P_RGT_CP Right control panel connector
196 Jumpers and connectors
System board jumper settings
For information on resetting the password jumper to disable a password, see the Disabling a forgotten password section.
Table 53. System board jumper settings
Jumper Setting Description
PWRD_EN The BIOS password feature is enabled.
The BIOS password feature is disabled. iDRAC local access is
unlocked at next AC power cycle. iDRAC password reset is enabled
in F2 iDRAC settings menu.
NVRAM_CLR The BIOS conguration settings are retained at system boot.
The BIOS conguration settings are cleared at system boot.
Disabling forgotten password
The software security features of the system include a system password and a setup password. The password jumper enables or disables
password features and clears any password(s) currently in use.
Prerequisite
CAUTION: Many repairs may only be done by a certied service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Steps
1 Power o the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Remove the system cover.
3 Move the jumper on the system board jumper from pins 2 and 4 to pins 4 and 6.
4 Install the system cover.
The existing passwords are not disabled (erased) until the system boots with the jumper on pins 4 and 6. However, before you assign a
new system and/or setup password, you must move the jumper back to pins 2 and 4.
NOTE: If you assign a new system and/or setup password with the jumper on pins 4 and 6, the system disables the new
password(s) the next time it boots.
5 Reconnect the system to its electrical outlet and power on the system, including any attached peripherals.
6 Power o the system, including any attached peripherals, and disconnect the system from the electrical outlet.
7 Remove the system cover.
8 Move the jumper on the system board jumper from pins 4 and 6 to pins 2 and 4.
9 Install the system cover.
10 Reconnect the system to its electrical outlet and power on the system, including any attached peripherals.
11 Assign a new system and/or setup password.
Jumpers and connectors 197
Getting help
Topics:
• Contacting Dell EMC
• Documentation feedback
• Accessing system information by using QRL
• Receiving automated support with SupportAssist
• Recycling or End-of-Life service information
Contacting Dell EMC
Dell EMC provides several online and telephone based support and service options. If you do not have an active internet connection, you
can nd contact information about your purchase invoice, packing slip, bill, or Dell EMC product catalog. Availability varies by country and
product, and some services may not be available in your area. To contact Dell EMC for sales, technical assistance, or customer service
issues:
1 Go to www.dell.com/support/home.
2 Select your country from the drop-down menu on the lower right corner of the page.
3 For customized support:
a Enter your system Service Tag in the Enter your Service Tag eld.
b Click Submit.
The support page that lists the various support categories is displayed.
4 For general support:
a Select your product category.
b Select your product segment.
c Select your product.
The support page that lists the various support categories is displayed.
5 For contact details of Dell EMC Global Technical Support:
a Click Global Technical Support.
b The Contact Technical Support page is displayed with details to call, chat, or e-mail the Dell EMC Global Technical Support
team.
Documentation feedback
You can rate the documentation or write your feedback on any of our Dell EMC documentation pages and click Send Feedback to send
your feedback.
Accessing system information by using QRL
You can use the Quick Resource Locator (QRL) located on the information tag in the front of the R740, to access the information about
the Dell EMC PowerEdge R740.
Prerequisites
Ensure that your smartphone or tablet has the QR code scanner installed.
9
198 Getting help
The QRL includes the following information about your system:
• How-to videos
• Reference materials, including the Installtion and Service Manual, LCD diagnostics, and mechanical overview
• Your system service tag to quickly access your specic hardware conguration and warranty information
• A direct link to Dell to contact technical assistance and sales teams
Steps
1 Go to www.dell.com/qrl and navigate to your specic product or
2 Use your smartphone or tablet to scan the model-specic Quick Resource (QR) code on your system or in the Quick Resource
Locator section.
Quick Resource Locator for PowerEdge R740 and R740xd
systems
Figure 139. Quick Resource Locator for PowerEdge R740 and R740xd systems
Receiving automated support with SupportAssist
Dell EMC SupportAssist is an optional Dell EMC Services oering that automates technical support for your Dell EMC server, storage, and
networking devices. By installing and setting up a SupportAssist application in your IT environment, you can receive the following benets:
•Automated issue detection — SupportAssist monitors your Dell EMC devices and automatically detects hardware issues, both
proactively and predictively.
•Automated case creation — When an issue is detected, SupportAssist automatically opens a support case with Dell EMC Technical
Support.
•Automated diagnostic collection — SupportAssist automatically collects system state information from your devices and uploads it
securely to Dell EMC. This information is used by Dell EMC Technical Support to troubleshoot the issue.
•Proactive contact — A Dell EMC Technical Support agent contacts you about the support case and helps you resolve the issue.
The available benets vary depending on the Dell EMC Service entitlement purchased for your device. For more information about
SupportAssist, go to www.dell.com/supportassist.
Recycling or End-of-Life service information
Take back and recycling services are oered for this product in certain countries. If you want to dispose of system components, visit
www.dell.com/recyclingworldwide and select the relevant country.
Getting help 199