Table of Contents
- Dell EMC PowerEdge T340 Installation and Service Manual
- About this document
- Dell EMC PowerEdge T340 system overview
- Initial system setup and configuration
- Pre-operating system management applications
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Front bezel
- System feet
- Caster wheels – optional
- System cover
- Air shroud
- Intrusion switch
- Drives
- Removing a drive blank
- Installing a drive blank
- Removing a drive carrier
- Installing the drive carrier
- Removing the drive from the drive carrier
- Installing the drive into the drive carrier
- Removing a 2.5-inch drive from the 3.5-inch drive adapter
- Installing a 2.5-inch drive into the 3.5-inch drive adapter
- Removing a 3.5-inch drive adapter from a 3.5-inch drive carrier
- Installing a 3.5-inch adapter into a 3.5-inch drive carrier
- Optical drive and tape drives
- Drive backplane
- Backplane cable routing
- Four-slot drive blank
- System memory
- Cooling fan
- Optional internal USB memory key
- Expansion cards
- M.2 SSD module
- Optional IDSDM or vFlash module
- Processor and heat sink
- Power supply unit
- Power interposer board
- System battery
- System board
- Trusted Platform Module
- Control panel
- Jumpers and connectors
- Technical specifications
- Chassis dimensions
- System weight
- Processor specifications
- Supported operating systems
- PSU specifications
- Cooling fan specifications
- System battery specifications
- Expansion card specifications
- Memory specifications
- Storage controller specifications
- Drive specifications
- Ports and connectors specifications
- Video specifications
- Environmental specifications
- System diagnostics and indicator codes
- Getting help
- Documentation resources
DELL T340 User Manual
Displayed below is the user manual for T340 by DELL which is a product in the Servers category. This manual has pages.
Related Manuals
Dell EMC PowerEdge T340
Installation and Service Manual
Regulatory Model: E60S
Regulatory Type: E60S001
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2018 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other
trademarks may be trademarks of their respective owners.
2019 - 06
Rev. A01
Contents
1 About this document...................................................................................................................................... 8
2 Dell EMC PowerEdge T340 system overview.................................................................................................9
Front view of the system.................................................................................................................................................10
Rear view of the system..................................................................................................................................................12
Inside the system.............................................................................................................................................................. 13
Locating the information tag of your system................................................................................................................ 15
System information label..................................................................................................................................................15
PowerEdge T340 – System information label........................................................................................................ 15
3 Initial system setup and conguration.......................................................................................................... 18
Setting up your system....................................................................................................................................................18
iDRAC conguration.........................................................................................................................................................18
Options to set up iDRAC IP address.........................................................................................................................18
Log in to iDRAC...........................................................................................................................................................18
Options to install the operating system......................................................................................................................... 19
Methods to download rmware and drivers........................................................................................................... 19
Downloading drivers and rmware.......................................................................................................................... 20
4 Pre-operating system management applications.......................................................................................... 21
Options to manage the pre-operating system applications.........................................................................................21
System Setup....................................................................................................................................................................21
Viewing System Setup............................................................................................................................................... 21
System Setup details.................................................................................................................................................22
System BIOS...............................................................................................................................................................22
iDRAC Settings utility................................................................................................................................................ 39
Device Settings.......................................................................................................................................................... 40
Dell Lifecycle Controller...................................................................................................................................................40
Embedded system management............................................................................................................................. 40
Boot Manager.................................................................................................................................................................. 40
Viewing Boot Manager..............................................................................................................................................40
Boot Manager main menu......................................................................................................................................... 41
One-shot UEFI boot menu........................................................................................................................................ 41
System Utilities........................................................................................................................................................... 41
PXE boot............................................................................................................................................................................41
5 Installing and removing system components................................................................................................ 42
Safety instructions...........................................................................................................................................................42
Before working inside your system................................................................................................................................42
After working inside your system...................................................................................................................................42
Recommended tools........................................................................................................................................................42
Front bezel........................................................................................................................................................................ 43
Contents 3
Removing the front bezel..........................................................................................................................................43
Installing the front bezel............................................................................................................................................44
System feet...................................................................................................................................................................... 44
Removing the system feet........................................................................................................................................44
Installing the system feet..........................................................................................................................................45
Caster wheels – optional................................................................................................................................................ 46
Removing caster wheels...........................................................................................................................................46
Installing caster wheels..............................................................................................................................................47
System cover....................................................................................................................................................................48
Removing the system cover.....................................................................................................................................48
Installing the system cover....................................................................................................................................... 49
Air shroud..........................................................................................................................................................................50
Removing the air shroud...........................................................................................................................................50
Installing the air shroud.............................................................................................................................................. 51
Intrusion switch................................................................................................................................................................52
Removing the intrusion switch.................................................................................................................................52
Installing the intrusion switch................................................................................................................................... 53
Drives.................................................................................................................................................................................54
Removing a drive blank............................................................................................................................................. 54
Installing a drive blank............................................................................................................................................... 55
Removing a drive carrier........................................................................................................................................... 56
Installing the drive carrier..........................................................................................................................................57
Removing the drive from the drive carrier............................................................................................................. 58
Installing the drive into the drive carrier..................................................................................................................58
Removing a 2.5-inch drive from the 3.5-inch drive adapter.................................................................................59
Installing a 2.5-inch drive into the 3.5-inch drive adapter.....................................................................................60
Removing a 3.5-inch drive adapter from a 3.5-inch drive carrier......................................................................... 61
Installing a 3.5-inch adapter into a 3.5-inch drive carrier......................................................................................62
Optical drive and tape drives..........................................................................................................................................63
Removing the optical or tape drive blank............................................................................................................... 63
Installing the optical or tape drive blank..................................................................................................................64
Removing the optical drive.......................................................................................................................................65
Installing the optical drive......................................................................................................................................... 66
Removing the tape drive...........................................................................................................................................67
Installing the tape drive............................................................................................................................................. 68
Drive backplane................................................................................................................................................................69
Drive backplane details..............................................................................................................................................69
Removing the drive backplane ................................................................................................................................ 70
Installing the drive backplane.................................................................................................................................... 71
Backplane cable routing.................................................................................................................................................. 72
Four-slot drive blank........................................................................................................................................................ 73
Removing a four-slot drive blank..............................................................................................................................73
Installing a four-slot drive blank................................................................................................................................ 74
System memory............................................................................................................................................................... 75
System memory guidelines....................................................................................................................................... 75
4Contents
General memory module installation guidelines...................................................................................................... 77
Removing a memory module.................................................................................................................................... 77
Installing a memory module.......................................................................................................................................78
Cooling fan........................................................................................................................................................................79
Removing the internal cooling fan............................................................................................................................79
Installing the internal cooling fan..............................................................................................................................80
Optional internal USB memory key.................................................................................................................................81
Replacing the optional internal USB memory key...................................................................................................81
Expansion cards .............................................................................................................................................................. 82
Expansion card guidelines......................................................................................................................................... 82
Removing an expansion card....................................................................................................................................83
Installing an expansion card...................................................................................................................................... 84
M.2 SSD module.............................................................................................................................................................. 86
Removing the M.2 SSD module...............................................................................................................................86
Installing the M.2 SSD module................................................................................................................................. 86
Optional IDSDM or vFlash module................................................................................................................................. 87
Removing the optional IDSDM or vFlash card........................................................................................................87
Installing optional IDSDM or vFlash card.................................................................................................................88
Removing the MicroSD card.................................................................................................................................... 89
Installing the MicroSD card.......................................................................................................................................89
Processor and heat sink..................................................................................................................................................90
Removing the heat sink............................................................................................................................................ 90
Removing the processor........................................................................................................................................... 92
Installing the processor............................................................................................................................................. 92
Installing the heat sink...............................................................................................................................................93
Power supply unit............................................................................................................................................................ 95
Removing the power supply unit blank................................................................................................................... 95
Installing the power supply unit blank......................................................................................................................96
Removing a redundant AC power supply unit........................................................................................................ 97
Installing a redundant AC power supply unit.......................................................................................................... 98
Removing a cabled power supply unit.....................................................................................................................99
Installing a cabled power supply unit......................................................................................................................100
Power interposer board..................................................................................................................................................101
Removing the power interposer board...................................................................................................................101
Installing the power interposer board.....................................................................................................................102
System battery .............................................................................................................................................................. 103
Replacing the system battery................................................................................................................................. 103
System board..................................................................................................................................................................104
Removing the system board................................................................................................................................... 104
Installing the system board......................................................................................................................................106
Trusted Platform Module...............................................................................................................................................108
Upgrading the Trusted Platform Module...............................................................................................................108
Initializing TPM for BitLocker users....................................................................................................................... 109
Initializing the TPM 1.2 for TXT users....................................................................................................................109
Initializing the TPM 2.0 for TXT users................................................................................................................... 109
Contents 5
Control panel....................................................................................................................................................................110
Removing the control panel assembly....................................................................................................................110
Installing the control panel assembly....................................................................................................................... 111
6 Jumpers and connectors ............................................................................................................................ 112
System board jumpers and connectors........................................................................................................................113
System board jumper settings....................................................................................................................................... 114
Disabling forgotten password........................................................................................................................................ 115
7 Technical specications.............................................................................................................................. 116
Chassis dimensions......................................................................................................................................................... 117
System weight................................................................................................................................................................. 117
Processor specications.................................................................................................................................................117
Supported operating systems........................................................................................................................................118
PSU specications.......................................................................................................................................................... 118
Cooling fan specications.............................................................................................................................................. 118
System battery specications........................................................................................................................................118
Expansion card specications........................................................................................................................................118
Memory specications....................................................................................................................................................119
Storage controller specications...................................................................................................................................119
Drive specications.........................................................................................................................................................119
Drives..........................................................................................................................................................................119
Optical drives............................................................................................................................................................ 120
Tape drives................................................................................................................................................................ 120
Ports and connectors specications............................................................................................................................120
USB ports specications......................................................................................................................................... 120
NIC ports specications.......................................................................................................................................... 120
Serial connector specications............................................................................................................................... 120
VGA ports specication...........................................................................................................................................120
IDSDM module...........................................................................................................................................................121
Video specications........................................................................................................................................................ 121
Environmental specications......................................................................................................................................... 121
Standard operating temperature............................................................................................................................ 123
Expanded operating temperature...........................................................................................................................123
Particulate and gaseous contamination specications........................................................................................ 124
8 System diagnostics and indicator codes .................................................................................................... 125
System health and system ID indicator codes............................................................................................................ 125
iDRAC Direct LED indicator codes............................................................................................................................... 125
NIC indicator codes........................................................................................................................................................126
Non-redundant cabled power supply unit indicator codes........................................................................................126
Power supply unit indicator codes................................................................................................................................127
Drive indicator codes......................................................................................................................................................128
Using system diagnostics.............................................................................................................................................. 129
Dell Embedded System Diagnostics.......................................................................................................................129
6Contents
9 Getting help................................................................................................................................................ 131
Recycling or End-of-Life service information...............................................................................................................131
Contacting Dell................................................................................................................................................................ 131
Accessing system information by using QRL...............................................................................................................131
Quick Resource Locator for Dell EMC PowerEdge T340 system...................................................................... 132
Receiving automated support with SupportAssist ....................................................................................................132
10 Documentation resources......................................................................................................................... 133
Contents 7
About this document
This document provides an overview about the system, information about installing and replacing components, technical specications,
diagnostic tools, and guidelines to be followed while installing certain components.
1
8 About this document
Dell EMC PowerEdge T340 system overview
The Dell EMC PowerEdge T340 system is a tower server that supports:
• One Intel Xeon Scalable processor
• Four DIMM slots
• Redundant and cabled AC power supply units
• Up to eight 3.5-inch or four 3.5-inch SAS, SATA drives or SSDs
For more information about supported drives, see the Drive specications section.
NOTE: All instances of SAS, SATA drives, and SSDs are referred to as drives in this document, unless specied otherwise.
Topics:
• Front view of the system
• Rear view of the system
• Inside the system
• Locating the information tag of your system
• System information label
2
Dell EMC PowerEdge T340 system overview 9
Front view of the system
Figure 1. Front view of 8 x 3.5-inch drive system
1Power button 2 Information tag
3 System health and system ID indicator 4 USB 3.0 port
5 iDRAC direct micro USB port 6 Optical drive (optional)
7 Drive (8)
10 Dell EMC PowerEdge T340 system overview
Figure 2. Front view of 4 x 3.5-inch drive system
1Power button 2 Information tag
3 System health and system ID indicator 4 USB 3.0 port
5 iDRAC direct micro USB port 6 Optical drive (optional)
7 Drive (4) 8 Four-slot drive blank
For more information about the ports, see the Ports and connectors specications section.
Dell EMC PowerEdge T340 system overview 11
Rear view of the system
Figure 3. Rear view of 8 x 3.5-inch drive system
1Power supply unit (PSU 1) 2 Power supply unit (PSU 2)
3 USB 2.0 port (4) 4 System Identication button
5 USB 3.0 port (2) 6 iDRAC dedicated NIC port
7 VGA port 8 Serial port
9 NIC port (Gb1) 10 NIC port (Gb2)
11 PCIe expansion card slots (4)
12 Dell EMC PowerEdge T340 system overview
Figure 4. Rear view of 4 x 3.5-inch drive system
1Cabled power supply unit (PSU) 2 USB 2.0 port (4)
3 System identication button 4 USB 3.0 port (2)
5 iDRAC dedicated NIC port 6 VGA port
7 Serial port 8 NIC port (Gb1)
9 NIC port (Gb2) 10 PCIe expansion card slots (4)
NOTE: For more information about the ports and connectors, see the Ports and connectors specications section.
Inside the system
NOTE: Components that are hot swappable are marked orange and touch points on the components are marked blue.
Dell EMC PowerEdge T340 system overview 13
Figure 5. Inside the system with cabled power supply unit (PSU)
1Optical drive or tape drive 2 Power supply unit (cabled)
3 PCIe Expansion card latch (4) 4 PCIe Expansion card slots (4)
5 Intrusion switch 6 Air shroud
7 Drive backplane
Figure 6. Inside the system with redundant power supply unit (PSU)
1Optical drive or tape drive 2 Power interposer board
3 PCIe Expansion card latch (4) 4 PCIe Expansion card slots (4)
14 Dell EMC PowerEdge T340 system overview
5 Intrusion switch 6 Fan
7 Memory module socket (4) 8 Processor and heat sink
9 System board 10 Drive backplane
Locating the information tag of your system
Your system is identied by a unique Express Service Code and Service Tag number. You can view the Express Service Code and Service
Tag by pulling out the information tag located on the front of the system. Alternatively, the information may be on the Mini Enterprise
Service Tag (MEST) label on the chassis, on the rear of the system. This information is used by Dell to route support calls to the
appropriate personnel.
Figure 7. Locating Service Tag of your system
1Information tag (top view) 2 Information tag (back view)
3 OpenManage Mobile (OMM) label 4 iDRAC MAC address and iDRAC secure password label
5 Service Tag, Express Service Code, QRL label
System information label
PowerEdge T340 – System information label
Figure 8. Mechanical overview
Dell EMC PowerEdge T340 system overview 15
Figure 9. Electrical overview
Figure 10. Icon legend
Figure 11. DVD and BOSS installation
Figure 12. CPU installation
16 Dell EMC PowerEdge T340 system overview
Figure 13. Heat sink installation
Figure 14. Internal cooling fan installation
Figure 15. Memory population
Figure 16. Quick resource locator
Dell EMC PowerEdge T340 system overview 17
Initial system setup and conguration
Setting up your system
Perform the following steps to set up your system:
1 Unpack the system.
2 Connect the peripherals to the system.
3 Connect the system to its electrical outlet.
4 Power on the system by pressing the power button or by using iDRAC.
5 Power on the attached peripherals.
For more information about setting up your system, see the Getting Started Guide that shipped with your system.
iDRAC conguration
The Integrated Dell Remote Access Controller (iDRAC) is designed to make system administrators more productive and improve the overall
availability of Dell systems. iDRAC alerts administrators about system issues and enables them to perform remote system management.
This reduces the need for physical access to the system.
Options to set up iDRAC IP address
To enable communication between your system and iDRAC, you must rst congure the network settings based on your network
infrastructure.
NOTE: For static IP conguration, you must request for it at the time of purchase.
This option is set to DHCP by Default. You can set up the IP address by using one of the following interfaces:
Interfaces Document/Section
iDRAC Settings
utility
Dell Integrated Dell Remote Access Controller User's Guide at Dell.com/poweredgemanuals
Dell Deployment
Toolkit
Dell Deployment Toolkit User’s Guide at Dell.com/openmanagemanuals > OpenManage Deployment Toolkit
Dell Lifecycle
Controller
Dell Lifecycle Controller User’s Guide at Dell.com/poweredgemanuals
NOTE: To access iDRAC, ensure that you connect the ethernet cable to the iDRAC9 dedicated network port. You can also access
iDRAC through the shared LOM mode, if you have opted for a system that has the shared LOM mode enabled.
Log in to iDRAC
You can log in to iDRAC as:
• iDRAC user
3
18 Initial system setup and conguration
• Microsoft Active Directory user
• Lightweight Directory Access Protocol (LDAP) user
If you have opted for secure default access to iDRAC, you must use the iDRAC secure default password available on the system
Information tag. If you have not opted for secure default access to iDRAC, then use the default user name and password –root and
calvin. You can also log in by using your Single Sign-On or Smart Card.
NOTE: You must have the iDRAC credentials to log in to iDRAC.
NOTE: Ensure that you change the default user name and password after setting up the iDRAC IP address.
NOTE: The Intel Quick Assist Technology (QAT) on the Dell EMC PowerEdge T340 is supported with chipset integration and is
enabled through an optional license. The license les are enabled on the sleds through iDRAC.
For more information about drivers, documentation, and white papers on the Intel QAT, see https://01.org/intel-quickassist-technology.
For more information about logging in to the iDRAC and iDRAC licenses, see the latest Integrated Dell Remote Access Controller User's
Guide at Dell.com/poweredgemanuals.
You can also access iDRAC by using RACADM. For more information, see the RACADM Command Line Interface Reference Guide at
Dell.com/poweredgemanuals.
Options to install the operating system
If the system is shipped without an operating system, install a supported operating system by using one of the following resources:
Table 1. Resources to install the operating system
Resources Location
iDRAC Dell.com/idracmanuals
Lifecycle Controller Dell.com/idracmanuals > Lifecycle Controller
OpenManage Deployment Toolkit Dell.com/openmanagemanuals > OpenManage Deployment Toolkit
Dell certied VMware ESXi Dell.com/virtualizationsolutions
Installation and How-to videos for supported operating systems on
PowerEdge systems
Supported Operating Systems for Dell EMC PowerEdge systems
Methods to download rmware and drivers
You can download the rmware and drivers by using any of the following methods:
Table 2. Firmware and drivers
Methods Location
From the Dell EMC support site Dell.com/support/home
Using Dell Remote Access Controller Lifecycle Controller (iDRAC
with LC)
Dell.com/idracmanuals
Using Dell Repository Manager (DRM) Dell.com/openmanagemanuals > Repository Manager
Using Dell OpenManage Essentials (OME) Dell.com/openmanagemanuals > OpenManage Essentials
Using Dell Server Update Utility (SUU) Dell.com/openmanagemanuals > Server Update Utility
Initial system setup and conguration 19
Methods Location
Using Dell OpenManage Deployment Toolkit (DTK) Dell.com/openmanagemanuals > OpenManage Deployment Toolkit
Using iDRAC virtual media Dell.com/idracmanuals
Downloading drivers and rmware
Dell EMC recommends that you download and install the latest BIOS, drivers, and systems management rmware on your system.
Prerequisite
Ensure that you clear the web browser cache before downloading the drivers and rmware.
Steps
1 Go to Dell.com/support/home.
2 In the Drivers & Downloads section, type the Service Tag of your system in the Enter a Service Tag or product ID box, and then click
Submit.
NOTE: If you do not have the Service Tag, select Detect Product to allow the system to automatically detect the
Service Tag, or click View products, and navigate to your product.
3 Click Drivers & Downloads.
The drivers that are applicable to your system are displayed.
4 Download the drivers to a USB drive, CD, or DVD.
20 Initial system setup and conguration
Pre-operating system management applications
You can manage basic settings and features of a system without booting to the operating system by using the system rmware.
Topics:
• Options to manage the pre-operating system applications
• System Setup
• Dell Lifecycle Controller
• Boot Manager
• PXE boot
Options to manage the pre-operating system
applications
Your system has the following options to manage the pre-operating system applications:
• System Setup
• Dell Lifecycle Controller
• Boot Manager
• Preboot Execution Environment (PXE)
System Setup
By using the System Setup screen, you can congure the BIOS settings, iDRAC settings, and device settings of your system.
NOTE: Help text for the selected eld is displayed in the graphical browser by default. To view the help text in the text browser,
press F1.
You can access system setup by one of the following:
• Standard graphical browser—The browser is enabled by default.
• Text browser—The browser is enabled by using Console Redirection.
Viewing System Setup
To view the System Setup screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
4
Pre-operating system management applications 21
System Setup details
The System Setup Main Menu screen details are explained as follows:
Option Description
System BIOS Enables you to congure BIOS settings.
iDRAC Settings Enables you to congure the iDRAC settings.
The iDRAC settings utility is an interface to set up and congure the iDRAC parameters by using UEFI (Unied
Extensible Firmware Interface). You can enable or disable various iDRAC parameters by using the iDRAC settings
utility. For more information about this utility, see Integrated Dell Remote Access Controller User’s Guide at
Dell.com/poweredgemanuals.
Device Settings Enables you to congure device settings.
System BIOS
You can use the System BIOS screen to edit specic functions such as boot order, system password, setup password, set the SATA mode,
and enable or disable USB ports.
Viewing System BIOS
To view the System BIOS screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If the operating system begins to load before you press F2, wait for the system to nish booting, and then
restart the system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
System BIOS Settings details
The System BIOS Settings screen details are explained as follows:
Option Description
System Information Species information about the system such as the system model name, BIOS version, and Service Tag.
Memory Settings Species information and options related to the installed memory.
Processor Settings Species information and options related to the processor such as speed and cache size.
SATA Settings Species options to enable or disable the integrated SATA controller and ports.
Boot Settings Species options to specify the Boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS boot settings.
Network Settings Species options to manage the UEFI network settings and boot protocols.
22 Pre-operating system management applications
Option Description
Legacy network settings are managed from the Device Settings menu.
Integrated Devices Species options to manage integrated device controllers and ports, species related features and options.
Serial
Communication
Species options to manage the serial ports, its related features and options.
System Prole
Settings
Species options to change the processor power management settings, memory frequency.
System Security Species options to congure the system security settings, such as system password, setup password, Trusted
Platform Module (TPM) security, and UEFI secure boot. It also manages the power button on the system.
Redundant OS
Control
Sets the redundant OS info for redundant OS control.
Miscellaneous
Settings
Species options to change the system date and time.
System Information
You can use the System Information screen to view system properties such as Service Tag, system model name, and BIOS version.
Viewing System Information
To view the System Information screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click System Information.
System Information details
The System Information screen details are explained as follows:
Option Description
System Model
Name
Species the system model name.
System BIOS
Version
Species the BIOS version installed on the system.
System
Management
Engine Version
Species the current version of the Management Engine rmware.
System Service Tag Species the system Service Tag.
System
Manufacturer
Species the name of the system manufacturer.
Pre-operating system management applications 23
Option Description
System
Manufacturer
Contact
Information
Species the contact information of the system manufacturer.
System CPLD
Version
Species the current version of the system complex programmable logic device (CPLD) rmware.
UEFI Compliance
Version
Species the UEFI compliance level of the system rmware.
Memory Settings
You can use the Memory Settings screen to view all the memory settings and enable or disable specic memory functions, such as system
memory testing and node interleaving.
Viewing Memory Settings
To view the Memory Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If the operating system begins to load before you press F2, wait for the system to nish booting, and then
restart the system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Memory Settings.
Memory Settings details
The Memory Settings screen details are explained as follows:
Option Description
System Memory
Size
Species the memory size in the system.
System Memory
Type
Species the type of memory installed in the system.
System Memory
Speed
Species the system memory speed.
System Memory
Voltage
Species the system memory voltage.
Video Memory Species the amount of video memory.
System Memory
Testing
Species whether the system memory tests are run during system boot. Options are Enabled and Disabled. This
option is set to Disabled by default.
Memory Operating
Mode
Species the memory operating mode. This option is set to Optimizer Mode by default.
NOTE: The Memory Operating Mode option can have dierent default and available options based on the
memory conguration of your system.
24 Pre-operating system management applications
Option Description
Current State of
Memory Operating
Mode
Species the current state of the memory operating mode.
Processor Settings
You can use the Processor Settings screen to view the processor settings, and perform specic functions such as enabling virtualization
technology, hardware prefetcher, and logical processor idling.
Viewing Processor Settings
To view the Processor Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Processor Settings.
Processor Settings details
The Processor Settings screen details are explained as follows:
Option Description
Logical Processor Enables or disables the logical processors and displays the number of logical processors. If this option is set to
Enabled, the BIOS displays all the logical processors. If this option is set to Disabled, the BIOS displays only one
logical processor per core. This option is set to Enabled by default.
Virtualization
Technology
Enables or disables the virtualization technology for the processor. This option is set to Enabled by default.
Adjacent Cache
Line Prefetch
Optimizes the system for applications that need high utilization of sequential memory access. This option is set to
Enabled by default. You can disable this option for applications that need high utilization of random memory
access.
Hardware
Prefetcher
Enables or disables the hardware prefetcher. This option is set to Enabled by default.
Logical Processor
Idling
Enables you to improve the energy eciency of a system. It uses the operating system core parking algorithm and
parks some of the logical processors in the system which in turn allows the corresponding processor cores to
transition into a lower power idle state. This option can only be enabled if the operating system supports it. It is set
to Disabled by default.
x2APIC Mode Enables or disables the x2APIC mode. This option is set to Disabled by default.
Number of Cores
per Processor
Controls the number of enabled cores in each processor. This option is set to All by default.
Processor Core
Speed
Species the maximum core frequency of the processor.
Pre-operating system management applications 25
Option Description
Processor 1 The following settings are displayed for each processor installed in the system:
Option Description
Family-Model-
Stepping
Species the family, model, and stepping of the processor as dened by Intel.
Brand Species the brand name.
Level 2 Cache Species the total L2 cache.
Level 3 Cache Species the total L3 cache.
Number of Cores Species the number of cores per processor.
Microcode Indicates the Microcode update signature.
SATA Settings
You can use the SATA Settings screen to view the SATA settings of SATA devices and enable SATA on your system.
Viewing SATA Settings
To view the SATA Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click SATA Settings.
SATA Settings details
The SATA Settings screen details are explained as follows:
Option Description
Embedded SATA Enables the embedded SATA option to be set to O, AHCI, or RAID modes. This option is set to AHCI Mode by
default.
Security Freeze
Lock
Sends Security Freeze Lock command to the embedded SATA drives during POST. This option is applicable only
for AHCI Mode. This option is set to Enabled by default.
Write Cache Enables or disables the command for the embedded SATA drives during POST. This option is set to Disabled by
default.
Port n Sets the drive type of the selected device.
For AHCI Mode or RAID Mode, BIOS support is always enabled.
Option Description
Model Species the drive model of the selected device.
26 Pre-operating system management applications
Option Description
Option Description
Drive Type Species the type of drive attached to the SATA port.
Capacity Species the total capacity of the drive. This eld is undened for removable media
devices such as optical drives.
Boot Settings
You can use the Boot Settings screen to set the boot mode to either BIOS or UEFI. It also enables you to specify the boot order.
•UEFI: The Unied Extensible Firmware Interface (UEFI) is a new interface between operating systems and platform rmware. The
interface consists of data tables with platform related information, boot and runtime service calls that are available to the operating
system and its loader. The following benets are available when the Boot Mode is set to UEFI:
– Support for drive partitions larger than 2 TB.
– Enhanced security (e.g., UEFI Secure Boot).
– Faster boot time.
•BIOS: The BIOS Boot Mode is the legacy boot mode. It is maintained for backward compatibility.
Viewing Boot Settings
To view the Boot Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Boot Settings.
Boot Settings details
The Boot Settings screen details are explained as follows:
Option Description
Boot Mode Enables you to set the boot mode of the system.
CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not
installed in the same boot mode.
If the operating system supports UEFI, you can set this option to UEFI. Setting this eld to BIOS allows
compatibility with non-UEFI operating systems. This option is set to UEFI by default.
NOTE: Setting this eld to UEFI disables the BIOS Boot Settings menu.
Boot Sequence
Retry
Enables or disables the Boot Sequence Retry feature. If this option is set to Enabled and the system fails to boot,
the system re-attempts the boot sequence after 30 seconds. This option is set to Enabled by default.
Hard-Disk Failover Species the drive that is booted in the event of a drive failure. The devices are selected in the Hard-Disk Drive
Sequence on the Boot Option Setting menu. When this option is set to Disabled, only the rst drive in the list is
attempted to boot. When this option is set to Enabled, all drives are attempted to boot in the order selected in the
Pre-operating system management applications 27
Option Description
Hard-Disk Drive Sequence. This option is not enabled for UEFI Boot Mode. This option is set to Disabled by
default.
Generic USB boot Enables or disables generic USB boot.
Hard-disk Drive
Placeholder
Enables or disables Hard-disk Drive Placeholder.
UEFI Boot Settings Enables or disables UEFI Boot options.
The Boot options include IPv4 PXE and IPv6 PXE. This option is set to IPv4 by default.
NOTE: This option is enabled only if the boot mode is UEFI.
Network Settings
You can use the Network Settings screen to modify UEFI PXE, iSCSI, and HTTP boot settings. The network settings option is available
only in the UEFI mode.
NOTE: BIOS does not control network settings in the BIOS mode. For the BIOS boot mode, the optional Boot ROM of the
network controllers handles the network settings.
Viewing Network Settings
To view the Network Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Network Settings.
Network Settings screen details
The Network Settings screen details are explained as follows:
Option Description
PXE Device n (n = 1
to 4)
Enables or disables the device. When enabled, a UEFI PXE boot option is created for the device.
PXE Device n
Settings(n = 1 to 4)
Enables you to control the conguration of the PXE device.
HTTP Device n (n =
1 to 4)
Enables or disables the device. When enabled, a UEFI HTTP boot option is created for the device.
HTTP Device n
Settings (n = 1 to 4)
Enables you to control the conguration of the HTTP device.
28 Pre-operating system management applications
UEFI iSCSI Settings
You can use the iSCSI Settings screen to modify iSCSI device settings. The iSCSI Settings option is available only in the UEFI boot mode.
BIOS does not control network settings in the BIOS boot mode. For the BIOS boot mode, the option ROM of the network controller
handles the network settings.
Viewing UEFI iSCSI Settings
To view the UEFI iSCSI Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Network Settings.
5 On the Network Settings screen, scroll down to view UEFI iSCSI Settings.
UEFI iSCSI Settings details
The UEFI iSCSI Settings screen details are explained as follows:
Option Description
iSCSI Initiator
Name
Species the name of the iSCSI initiator (iqn format).
iSCSI Device1 Enables or disables the iSCSI device. When enabled, a UEFI boot option is created for the iSCSI device
automatically.
iSCSI Device1
Settings
Enables you to control the conguration of the iSCSI device.
Integrated Devices
You can use the Integrated Devices screen to view and congure the settings of all integrated devices including the video controller,
integrated RAID controller, and the USB ports.
Viewing Integrated Devices
To view the Integrated Devices screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
Pre-operating system management applications 29
4 On the System BIOS screen, click Integrated Devices.
Integrated Devices details
The Integrated Devices screen details are explained as follows:
Option Description
User Accessible
USB Ports
Congures the user accessible USB ports. Selecting Only Back Ports On disables the front USB ports; selecting
All Ports O disables all front and back USB ports;
The USB keyboard and mouse still function in certain USB ports during the boot process, depending on the
selection. After the boot process is complete, the USB ports will be enabled or disabled as per the setting.
NOTE: Selecting Only Back Ports On and All Ports O disables the USB management port and also
restricts access to the iDRAC features.
Internal USB Port Enables or disables the internal USB port. This option is set to On or O. This option is set to On by default.
iDRAC Direct USB
Port
The iDRAC Direct USB port is managed by iDRAC exclusively with no host visibility. This option is set to ON or
OFF. When set to OFF, iDRAC does not detect any USB devices installed in this managed port. This option is set
to On by default.
Embedded NIC1
and NIC2 NOTE: The Embedded NIC1 and NIC2 options are only available on systems that do not have Integrated
Network Card 1.
Enables or disables the Embedded NIC1 and NIC2 options. If set to Disabled, the NIC may still be available for
shared network access by the embedded management controller. The embedded NIC1 and NIC2 options are only
available on systems that do not have Network Daughter Cards (NDCs). The Embedded NIC1 and NIC2 option is
mutually exclusive with the Integrated Network Card 1 option. Congure the Embedded NIC1 and NIC2 option by
using the NIC management utilities of the system.
I/OAT DMA Engine Enables or disables the I/O Acceleration Technology (I/OAT) option. I/OAT is a set of DMA features designed to
accelerate network trac and lower CPU utilization. Enable only if the hardware and software support the feature.
Embedded Video
Controller
Enables or disables the use of Embedded Video Controller as the primary display. When set to Enabled, the
Embedded Video Controller will be the primary display even if add-in graphic cards are installed. When set to
Disabled, an add-in graphics card will be used as the primary display. BIOS will output displays to both the primary
add-in video and the embedded video during POST and pre-boot environment. The embedded video will then be
disabled right before the operating system boots. This option is set to Enabled by default.
NOTE: When there are multiple add-in graphic cards installed in the system, the rst card discovered
during PCI enumeration is selected as the primary video. You might have to re-arrange the cards in the
slots in order to control which card is the primary video.
Current State of
Embedded Video
Controller
Displays the current state of the embedded video controller. The Current State of Embedded Video Controller
option is a read-only eld. If the Embedded Video Controller is the only display capability in the system (that is, no
add-in graphics card is installed), then the Embedded Video Controller is automatically used as the primary display
even if the Embedded Video Controller setting is set to Enabled.
OS Watchdog
Timer
If your system stops responding, this watchdog timer aids in the recovery of your operating system. When this
option is set to Enabled, the operating system initializes the timer. When this option is set to Disabled (the
default), the timer does not have any eect on the system.
Memory Mapped
I/O above 4 GB
Enables or disables the support for the PCIe devices that need large amounts of memory. Enable this option only
for 64-bit operating systems. This option is set to Enabled by default.
Slot Disablement Enables or disables the available PCIe slots on your system. The slot disablement feature controls the conguration
of the PCIe cards installed in the specied slot. Slots must be disabled only when the installed peripheral card
prevents booting into the operating system or causes delays in system startup. If the slot is disabled, both the
Option ROM and UEFI drivers are disabled. Only slots that are present on the system will be available for control.
30 Pre-operating system management applications
Option Description
Table 3. Slot Disablement
Option Description
Slot 1 Enables or disables or only the boot driver is disabled
for the PCIe slot 1. This option is set to Enabled by
default.
Slot 2 Enables or disables or only the boot driver is disabled
for the PCIe slot 2. This option is set to Enabled by
default.
Slot 3 Enables or disables or only the boot driver is disabled
for the PCIe slot 3. This option is set to Enabled by
default.
Slot 4 Enables or disables or only the boot driver is disabled
for the PCIe slot 4. This option is set to Enabled by
default.
Serial Communication
You can use the Serial Communication screen to view the properties of the serial communication port.
Viewing Serial Communication
To view the Serial Communication screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Serial Communication.
Serial Communication details
The Serial Communication screen details are explained as follows:
Option Description
Serial
Communication Selects serial communication devices (Serial Device 1 and Serial Device 2) in BIOS. BIOS console redirection can
also be enabled, and the port address can be specied. This option is set to Auto by default.
Serial Port Address Enables you to set the port address for serial devices. This eld sets the serial port address to either COM1 or
COM2 (COM1=0x3F8, COM2=0x2F8). This option is set to Serial Device1=COM2 or Serial Device 2=COM1 by
default.
Pre-operating system management applications 31
Option Description
NOTE: You can use only Serial Device 2 for the Serial Over LAN (SOL) feature. To use console
redirection by SOL, congure the same port address for console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The serial
MUX setting can independently be changed in iDRAC. Loading the BIOS default settings from within the
BIOS setup utility may not always revert the serial MUX setting to the default setting of Serial Device 1.
External Serial
Connector Enables you to associate the External Serial Connector to Serial Device 1, Serial Device 2, or the Remote Access
Device by using this option. This option is set to Serial Device 1 by default.
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console redirection by SOL,
congure the same port address for console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX setting saved in iDRAC. The serial
MUX setting can independently be changed in iDRAC. Loading the BIOS default settings from within the
BIOS setup utility may not always revert this setting to the default setting of Serial Device 1.
Failsafe Baud Rate Species the failsafe baud rate for console redirection. The BIOS attempts to determine the baud rate
automatically. This failsafe baud rate is used only if the attempt fails, and the value must not be changed. This
option is set to 115200 by default.
Remote Terminal
Type
Sets the remote console terminal type. This option is set to ANSIVT100/VT220 by default.
Redirection After
Boot
Enables or disables the BIOS console redirection when the operating system is loaded. This option is set to
Enabled by default.
System Prole Settings
You can use the System Prole Settings screen to enable specic system performance settings such as power management.
Viewing System Prole Settings
To view the System Prole Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click System Prole Settings.
System Prole Settings details
The System Prole Settings screen details are explained as follows:
Option Description
System Prole Sets the system prole. If you set the System Prole option to a mode other than Custom, the BIOS automatically
sets the rest of the options. You can only change the rest of the options if the mode is set to Custom. This option
is set to Performance Per Watt (OS) by default.
32 Pre-operating system management applications
Option Description
NOTE: All the parameters on the system prole setting screen are available only when the System Prole
option is set to Custom.
CPU Power
Management
Sets the CPU power management. This option is set to OS DBPM by default.
Memory Frequency Sets the speed of the system memory. You can select Maximum Performance, Maximum Reliability, or a specic
speed. This option is set to Maximum Performance by default.
Turbo Boost Enables or disables the processor to operate in the turbo boost mode. This option is set to Enabled by default.
C1E Enables or disables the processor to switch to a minimum performance state when it is idle. This option is set to
Enabled by default.
C States Enables or disables the processor to operate in all available power states. This option is set to Enabled by default.
Memory Refresh
Rate
Sets the memory refresh rate to either 1x or 2x. This option is set to 1x by default.
Uncore Frequency Enables you to select the Processor Uncore Frequency option.
Dynamic mode enables the processor to optimize power resources across the cores and uncore during runtime.
The optimization of the uncore frequency to either save power or optimize performance is inuenced by the
setting of the Energy Eciency Policy option.
Number of Turbo
Boost Enabled
Cores for Processor
1
NOTE: If there are two processors installed in the system, you will see an entry for Number of Turbo
Boost Enabled Cores for Processor 2.
Controls the number of turbo boost enabled cores for Processor 1. The maximum number of cores is enabled by
default.
Monitor/Mwait Enables the Monitor/Mwait instructions in the processor. This option is set to Enabled for all system proles,
except Custom by default.
NOTE: This option can be disabled only if the C States option in the Custom mode is set to disabled.
NOTE: When C States is set to Enabled in the Custom mode, changing the Monitor/Mwait setting does
not impact the system power or performance.
PCI ASPM L1 Link
Power
Management
Enables or disables the PCI ASPM L1 Link Power Management. This option is set to Enabled by default.
System Security
You can use the System Security screen to perform specic functions such as setting the system password, setup password and disabling
the power button.
Viewing System Security
To view the System Security screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
Pre-operating system management applications 33
4 On the System BIOS screen, click System Security.
System Security Settings details
The System Security Settings screen details are explained as follows:
Option Description
CPU AES-NI Improves the speed of applications by performing encryption and decryption by using the Advanced Encryption
Standard Instruction Set (AES-NI). This option is set to Enabled by default.
System Password Sets the system password. This option is set to Enabled by default and is read-only if the password jumper is not
installed in the system.
Setup Password Sets the setup password. This option is read-only if the password jumper is not installed in the system.
Password Status Locks the system password. This option is set to Unlocked by default.
TPM Security NOTE: The TPM menu is available only when the TPM module is installed.
Enables you to control the reporting mode of the TPM. The TPM Security option is set to O by default. You can
only modify the TPM Status, and TPM Activation elds if the TPM Status eld is set to either On with Pre-boot
Measurements or On without Pre-boot Measurements.
TPM Information Changes the operational state of the TPM. This option is set to No Change by default.
TPM Status Species the TPM status.
TPM Command Controls the Trusted Platform Module (TPM). When set to None, no command is sent to the TPM. When set to
Activate, the TPM is enabled and activated. When set to Deactivate, the TPM is disabled and deactivated. When
set to Clear, all the contents of the TPM are cleared. This option is set to None by default.
CAUTION: Clearing the TPM results in the loss of all keys in the TPM. The loss of TPM keys may aect
booting to the operating system.
This eld is read-only when TPM Security is set to O. The action requires an additional reboot before it can take
eect.
Intel(R) TXT Enables or disables the Intel Trusted Execution Technology (TXT) option. To enable the Intel TXT option,
virtualization technology and TPM Security must be enabled with Pre-boot measurements. This option is set to O
by default.
When TPM 2.0 is installed, TPM 2 Algorithm option is available. It enables you to select a hash algorithm from
those supported by the TPM (SHA1, SHA256). TPM 2 Algorithm option must be set to SHA256, to enable TXT.
Intel(R) SGX Enables or disables the Intel Software Guard Extension (SGX) option. This option is set to Software by default.
NOTE: The SGX menu is available, only when E-2186G/E-2176G/E-2174G CPU is installed
SGX Launch
Control Policy
Allows controlling the Launch Control Policy (LCP) of Software Guard Extensions (SGX) technology. This option is
set to Unlocked by default.
Power Button Enables or disables the power button on the front of the system. This option is set to Enabled by default.
AC Power Recovery Sets how the system behaves after AC power is restored to the system. This option is set to Last by default.
AC Power Recovery
Delay
Sets the time delay for the system to power up after AC power is restored to the system. This option is set to
Immediate by default.
User Dened Delay
(60 s to 240 s)User
Dened Delay (60 s
to 600 s)
Sets the User Dened Delay option when the User Dened option for AC Power Recovery Delay is selected.
34 Pre-operating system management applications
Option Description
UEFI Variable
Access
Provides varying degrees of securing UEFI variables. When set to Standard (the default), UEFI variables are
accessible in the operating system per the UEFI specication. When set to Controlled, selected UEFI variables are
protected in the environment and new UEFI boot entries are forced to be at the end of the current boot order.
In-Band
Manageability
Interface
When set to Disabled, this setting will hide the Management Engine's (ME), HECI devices, and the system's IPMI
devices from the operating system. This prevents the operating system from changing the ME power capping
settings, and blocks access to all in-band management tools. All management should be managed through out-of-
band. This option is set to Enabled by default.
NOTE: BIOS update requires HECI devices to be operational and DUP updates require IPMI interface to
be operational. This setting needs to be set to Enabled to avoid updating errors.
Secure Boot Enables Secure Boot, where the BIOS authenticates each pre-boot image by using the certicates in the Secure
Boot Policy. Secure Boot is set to Disabled by default.
Secure Boot Policy When Secure Boot policy is set to Standard, the BIOS uses the system manufacturer’s key and certicates to
authenticate pre-boot images. When Secure Boot policy is set to Custom, the BIOS uses the user-dened key and
certicates. Secure Boot policy is set to Standard by default.
Secure Boot Mode Congures how the BIOS uses the Secure Boot Policy Objects (PK, KEK, db, dbx).
If the current mode is set to Deployed Mode, the available options are User Mode and Deployed Mode. If the
current mode is set to User Mode, the available options are User Mode, Audit Mode, and Deployed Mode.
Options Description
User Mode In User Mode, PK must be installed, and BIOS performs signature verication on
programmatic attempts to update policy objects.
The BIOS allows unauthenticated programmatic transitions between modes.
Audit Mode In Audit mode, PK is not present. The BIOS does not authenticate programmatic updates
to the policy objects, and transitions between modes.
Audit Mode is useful for programmatically determining a working set of policy objects.
BIOS performs signature verication on pre-boot images and logs results in the image
Execution Information Table, but executes the images whether they pass or fail
verication.
Deployed Mode Deployed Mode is the most secure mode. In Deployed Mode, PK must be installed and
the BIOS performs signature verication on programmatic attempts to update policy
objects.
Deployed Mode restricts the programmatic mode transitions.
Secure Boot Policy
Summary
Species the list of certicates and hashes that secure boot uses to authenticate images.
Secure Boot
Custom Policy
Settings
Congures the Secure Boot Custom Policy. To enable this option, set the Secure Boot Policy to Custom option.
Pre-operating system management applications 35
Creating a system and setup password
Prerequisite
Ensure that the password jumper is enabled. The password jumper enables or disables the system password and setup password features.
For more information, see the System board jumper settings section.
NOTE: If the password jumper setting is disabled, the existing system password and setup password are deleted and you need
not provide the system password to boot the system.
Steps
1 To enter System Setup, press F2 immediately after turning on or rebooting your system.
2 On the System Setup Main Menu screen, click System BIOS > System Security.
3 On the System Security screen, verify that Password Status is set to Unlocked.
4 In the System Password eld, type your system password, and press Enter or Tab.
Use the following guidelines to assign the system password:
• A password can have up to 32 characters.
• The password can contain the numbers 0 through 9.
• Only the following special characters are allowed: space, (”), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`).
A message prompts you to reenter the system password.
5 Reenter the system password, and click OK.
6 In the Setup Password eld, type your setup password and press Enter or Tab.
A message prompts you to reenter the setup password.
7 Reenter the setup password, and click OK.
8 Press Esc to return to the System BIOS screen. Press Esc again.
A message prompts you to save the changes.
NOTE: Password protection does not take eect until the system reboots.
Using your system password to secure the system
About this task
If you have assigned a setup password, the system accepts your setup password as an alternate system password.
Steps
1 Power on or reboot your system.
2 Type the system password and press Enter.
Next step
When Password Status is set to Locked, type the system password and press Enter when prompted at reboot.
NOTE: If an incorrect system password is typed, the system displays a message and prompts you to reenter your password. You
have three attempts to type the correct password. After the third unsuccessful attempt, the system displays an error message
that the system has stopped functioning and must be turned o. Even after you turn o and restart the system, the error
message is displayed until the correct password is entered.
36 Pre-operating system management applications
Deleting or changing system and setup password
Prerequisite
NOTE: You cannot delete or change an existing system or setup password if the Password Status is set to Locked.
Steps
1 To enter System Setup, press F2 immediately after turning on or restarting your system.
2 On the System Setup Main Menu screen, click System BIOS > System Security.
3 On the System Security screen, ensure that Password Status is set to Unlocked.
4 In the System Password eld, change or delete the existing system password, and then press Enter or Tab.
5 In the Setup Password eld, alter or delete the existing setup password, and then press Enter or Tab.
NOTE: If you change the system password or setup password, a message prompts you to reenter the new password. If
you delete the system password or setup password, a message prompts you to conrm the deletion.
6 Press Esc to return to the System BIOS screen. Press Esc again, and a message prompts you to save the changes.
7 Select Setup Password, change, or delete the existing setup password and press Enter or Tab.
NOTE: If you change the system password or setup password, a message prompts you to reenter the new password. If
you delete the system password or setup password, a message prompts you to conrm the deletion.
Operating with setup password enabled
If Setup Password is set to Enabled, type the correct setup password before modifying the system setup options.
If you do not type the correct password in three attempts, the system displays the following message:
Invalid Password! Number of unsuccessful password attempts: <x> System Halted! Must power down.
Password Invalid. Number of unsuccessful password attempts: <x> Maximum number of password
attempts exceeded.System halted.
Even after you turn o and restart the system, the error message is displayed until the correct password is typed. The following options are
exceptions:
• If System Password is not set to Enabled and is not locked through the Password Status option, you can assign a system password.
For more information, see the System Security Settings screen section.
• You cannot disable or change an existing system password.
NOTE: You can use the password status option with the setup password option to protect the system password from
unauthorized changes.
Pre-operating system management applications 37
Redundant OS Control
In the Redundant OS Control screen you can set the redundant OS information. This enables you to set up a physical recovery disk on the
system.
Viewing Redundant OS Control
To view the Redundant OS Control screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Redundant OS Control.
Redundant OS Control screen details
The Redundant OS Control screen details are explained as follows:
Option Description
Redundant OS
Location
Enables you to select a backup disk from the following devices:
•None
•IDSDM
•SATA Ports in AHCI mode
•BOSS PCIe Cards (Internal M.2 Drives)
•Internal USB
NOTE: RAID congurations and NVMe cards not are included as BIOS does not have the ability to
distinguish between individual drives in those congurations.
Redundant OS
State NOTE: This option is disabled if Redundant OS Location is set to None.
When set to Visible, the backup disk is visible to the boot list and OS. When set to Hidden, the backup disk is
disabled and is not visible to the boot list and OS. This option is set to Visible by default.
NOTE: BIOS will disable the device in hardware, so it cannot be accessed by the OS.
Redundant OS Boot NOTE: This option is disabled if Redundant OS Location is set to None or if Redundant OS State is set to
Hidden.
When set to Enabled, BIOS boots to the device specied in Redundant OS Location. When set to Disabled, BIOS
preserves the current boot list settings. This option is set to Enabled by default.
38 Pre-operating system management applications
Miscellaneous Settings
You can use the Miscellaneous Settings screen to perform specic functions such as updating the asset tag and changing the system
date and time.
Viewing Miscellaneous Settings
To view the Miscellaneous Settings screen, perform the following steps:
1 Power on, or restart your system.
2 Press F2 immediately after you see the following message:
F2 = System Setup
NOTE: If your operating system begins to load before you press F2, wait for the system to nish booting, and then
restart your system and try again.
3 On the System Setup Main Menu screen, click System BIOS.
4 On the System BIOS screen, click Miscellaneous Settings.
Miscellaneous Settings details
The Miscellaneous Settings screen details are explained as follows:
Option Description
System Time Enables you to set the time on the system.
System Date Enables you to set the date on the system.
Asset Tag Species the asset tag and enables you to modify it for security and tracking purposes.
Keyboard NumLock Enables you to set whether the system boots with the NumLock enabled or disabled. This option is set to On by
default.
NOTE: This option does not apply to 84-key keyboards.
F1/F2 Prompt on
Error
Enables or disables the F1/F2 prompt on error. This option is set to Enabled by default. The F1/F2 prompt also
includes keyboard errors.
Load Legacy Video
Option ROM
Enables you to determine whether the system BIOS loads the legacy video (INT 10H) option ROM from the video
controller. Selecting Enabled in the operating system does not support UEFI video output standards. This eld is
available only for UEFI boot mode. You cannot set the option to Enabled if UEFI Secure Boot mode is enabled.
This option is set to Disabled by default.
Dell Wyse P25/P45
BIOS Access
Enables or disables the Dell Wyse P25/P45 BIOS Access. This option is set to Enabled by default.
Power Cycle
Request
Enables or disables the Power Cycle Request. This option is set to None by default.
iDRAC Settings utility
The iDRAC settings utility is an interface to set up and congure the iDRAC parameters by using UEFI. You can enable or disable various
iDRAC parameters by using the iDRAC settings utility.
NOTE: Accessing some of the features on the iDRAC settings utility needs the iDRAC Enterprise License upgrade.
Pre-operating system management applications 39
For more information about using iDRAC, see Dell Integrated Dell Remote Access Controller User's Guide at Dell.com/poweredgemanuals.
Device Settings
Device Settings enables you to congure the below device parameters:
• Controller Conguration Utility
• Embedded NIC Port1-X Conguration
• NICs in slotX, Port1-X Conguration
• BOSS Card conguration
Dell Lifecycle Controller
Dell Lifecycle Controller (LC) provides advanced embedded systems management capabilities including system deployment, conguration,
update, maintenance, and diagnosis. LC is delivered as part of the iDRAC out-of-band solution and Dell system embedded Unied
Extensible Firmware Interface (UEFI) applications.
Embedded system management
The Dell Lifecycle Controller provides advanced embedded system management throughout the lifecycle of the system. The Dell Lifecycle
Controller can be started during the boot sequence and can function independently of the operating system.
NOTE: Certain platform congurations may not support the full set of features provided by the Dell Lifecycle Controller.
For more information about setting up the Dell Lifecycle Controller, conguring hardware and rmware, and deploying the operating system,
see the Dell Lifecycle Controller documentation at Dell.com/poweredgemanuals.
Boot Manager
The Boot Manager screen enables you to select boot options and diagnostic utilities.
Viewing Boot Manager
About this task
To enter Boot Manager:
Steps
1 Power on, or restart your system.
2 Press F11 when you see the following message:
F11 = Boot Manager
If your operating system begins to load before you press F11, allow the system to complete the booting, and then restart your system
and try again.
40 Pre-operating system management applications
Boot Manager main menu
Menu item Description
Continue Normal
Boot
The system attempts to boot to devices starting with the rst item in the boot order. If the boot attempt fails, the
system continues with the next item in the boot order until the boot is successful or no more boot options are
found.
One-shot Boot
Menu
Enables you to access boot menu, where you can select a one-time boot device to boot from.
Launch System
Setup
Enables you to access System Setup.
Launch Lifecycle
Controller
Exits the Boot Manager and invokes the Dell Lifecycle Controller program.
System Utilities Enables you to launch System Utilities menu such as System Diagnostics and UEFI shell.
One-shot UEFI boot menu
One-shot UEFI boot menu enables you to select a boot device to boot from.
System Utilities
System Utilities contains the following utilities that can be launched:
• Launch Diagnostics
• BIOS Update File Explorer
• Reboot System
PXE boot
You can use the Preboot Execution Environment (PXE) option to boot and congure the networked systems, remotely.
To access the PXE boot option, boot the system and then press F12 during POST instead of using standard Boot Sequence from BIOS
Setup. It does not pull any menu or allows managing of network devices.
Pre-operating system management applications 41
Installing and removing system components
Safety instructions
WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the system by
yourself.
WARNING: Opening or removing the system cover while the system is powered on may expose you to a risk of electric shock.
CAUTION: Do not operate the system without the cover for a duration exceeding ve minutes. Operating the system without the
system cover can result in component damage.
CAUTION: Many repairs may only be done by a certied service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
CAUTION: To ensure proper operation and cooling, all bays in the system and system fans must be always populated with a
component or a blank.
NOTE: It is recommended that you always use an antistatic mat and antistatic strap while working on components inside the
system.
Before working inside your system
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Power o the system and all attached peripherals.
2 Disconnect the system from the electrical outlet, and disconnect the peripherals.
3 Remove the system cover.
After working inside your system
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Install the system cover.
2 Place the system upright on a at, stable surface.
3 Reconnect the peripherals and connect the system to the electrical outlet.
4 Power on the attached peripherals and then power on the system.
Recommended tools
You need the following tools to perform the removal and installation procedures:
• Key to the bezel lock
The key is required only if your system includes a bezel.
5
42 Installing and removing system components
• Phillips #1 screwdriver
• Phillips #2 screwdriver
• 5mm hex nut screwdriver
• Plastic scribe
• Wrist grounding strap connected to the ground
• ESD mat
Front bezel
Removing the front bezel
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Keep the bezel key handy.
Steps
1 Unlock the bezel.
2 Press the blue release latch at the top of the bezel to release the bezel from the system.
3 Unhook the bezel tabs from the slots at the bottom, and lift the bezel.
Figure 17. Removing the front bezel
Next step
1Replace the front bezel.
Installing and removing system components 43
Installing the front bezel
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Locate and remove the bezel key.
NOTE: The bezel key is part of the bezel package.
Steps
1 Align and insert the bezel tabs into the slots in the system.
2 Press the release latch, and push the bezel toward the system until the bezel locks into place.
3 Lock the bezel.
Figure 18. Installing the front bezel
System feet
Removing the system feet
Prerequisites
NOTE: It is recommended that you remove the system feet only when you are replacing the system feet with the wheel
assembly.
1 Follow the safety guidelines listed in Safety instructions..
2 Place the system on its side on a at, stable surface.
3 Rotate the system feet inward.
44 Installing and removing system components
Steps
1 Using the Phillips #2 screwdriver, remove the screw that secures the foot to the base of the system.
2 Repeat the preceding step to remove the remaining system feet.
Figure 19. Removing the system feet
Next step
1Replace the system feet or install the caster wheels.
Installing the system feet
Prerequisites
CAUTION: Install the feet on a stand-alone tower system to provide stability to the system. An unstable system might tip over
and cause injury to the user or damage to the system.
1 Follow the safety guidelines listed in Safety instructions.
2 Place the system on its side on a at, stable surface.
Steps
1 Align the three tabs on the system foot with the three slots on the base of the system.
2 Using the Phillips #2 screwdriver, secure the screw that secures the foot to the base of the system.
3 Repeat the above steps to install the remaining system feet.
Installing and removing system components 45
Figure 20. Installing the system feet
Next steps
1 Place the system upright on a at, stable surface, and rotate the system feet outward.
2 Follow the procedure listed in After working inside your system.
Caster wheels – optional
Removing caster wheels
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Place the system on its side on a at, stable surface.
Steps
1 Using the Phillips #2 screwdriver, loosen the captive screw that secures the front wheel unit to the base of the system.
2 Push the front wheel unit toward the rear of the system to release the retention hooks, and pull out the front wheel unit.
3 Loosen the screw that secures the back wheel unit to the base of the system.
4 Push the rear wheel unit toward the front of the system to release the retention hooks, and pull out the rear wheel unit.
46 Installing and removing system components
Next step
1Replace the caster wheels or replace the system feet, as applicable.
Installing caster wheels
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Place the system on its side on a at, stable surface.
3 If installed, remove the system feet.
Steps
1 Align the two retention hooks on the rear wheel unit with the two slots on the base of the system, and insert the hooks into the slots.
2 Push the rear wheel unit toward the back of the system and using a Phillips #2 screwdriver secure the unit in place using a single
screw.
3 Align the two retention hooks on the front wheel unit with the two slots on the base of the system, and insert the hooks into the slots.
4 Push the front wheel unit toward the front of the system and using a Phillips #2 screwdriver secure the unit in place using a single
screw.
Installing and removing system components 47
Figure 21. Installing caster wheels
Next step
1 Follow the procedure listed in After working inside your system.
System cover
Removing the system cover
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Power o the system and all attached peripherals.
3 Disconnect the system from the electrical outlet and disconnect the peripherals.
4 Place the system on a at, stable surface.
5Remove the front bezel.
Steps
1 Use a 1/4-inch at head or a Phillips #2 screwdriver to turn the cover release latch counterclockwise to the unlock position.
2 Press the cover release latch, and remove the system cover.
48 Installing and removing system components
Figure 22. Removing the system cover
Installing the system cover
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2Remove the front bezel.
3 Power o the system and all attached peripherals.
4 Disconnect the system from the electrical outlet and disconnect the peripherals.
5 Ensure that all internal cables are connected and placed out of the way and no tools or extra parts are left inside the system.
Steps
1 Align the tabs on the system cover with the slots on the system.
2 Press the cover release latch, and push the cover toward the system until the latch locks into place.
3 Using a 1/4-inch at head or a Phillips #2 screwdriver, rotate the cover release latch lock clockwise to the locked position.
Installing and removing system components 49
Figure 23. Installing the system cover
Next steps
1 Place the system upright on its feet on a at, stable surface.
2Install the front bezel.
3 Reconnect the peripherals, and connect the system to the electrical outlet.
4 Power on the system and all attached peripherals.
Air shroud
Removing the air shroud
Prerequisites
CAUTION: Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in
shutdown of the system and loss of data.
1Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the system cover.
Step
Holding the blue touch points, lift the air shroud out of the system.
50 Installing and removing system components
Figure 24. Removing the air shroud
Next step
1Replace the air shroud.
Installing the air shroud
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 If applicable, route the cables inside the system along the system wall and secure the cables by using the cable-securing bracket.
Steps
1 Align the tabs on the air shroud with the slots on the system.
2 Lower the air shroud into the system until it is rmly seated.
Installing and removing system components 51
Figure 25. Installing the air shroud
Next steps
1Install the system cover.
2 Follow the procedure listed in Before working inside your system.
Intrusion switch
Removing the intrusion switch
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Keep the plastic scribe ready.
Steps
1 Disconnect the intrusion switch cable connector from the system board.
NOTE: Observe the routing of the cable as you remove it from the system. Route the cable properly when you replace it
to prevent the cable from being pinched or crimped.
2 Using the plastic scribe, slide the intrusion switch out of the intrusion switch slot.
52 Installing and removing system components
Figure 26. Removing the intrusion switch
Next step
1Replace the intrusion switch.
Installing the intrusion switch
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Align and slide the intrusion switch into the slot in the system.
2 Connect the intrusion switch cable connector to the intrusion switch connector on the system board.
Installing and removing system components 53
Figure 27. Installing the intrusion switch
Next steps
1Install the air shroud.
2 Follow the procedure that is listed in After working inside your system.
Drives
Removing a drive blank
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not supported.
Step
Press the release tab, and slide the drive blank out.
54 Installing and removing system components
Figure 28. Removing a drive blank
NOTE: The procedure to remove a 2.5-inch or a 3.5-inch drive blank is the same.
Next step
1Replace the drive or a drive blank.
Installing a drive blank
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure in Before working inside your system.
3Remove the front bezel.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all empty drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not supported.
Step
Slide the drive blank into the drive slot until the release tab clicks into place.
Figure 29. Installing a drive blank
Next steps
1Replace the front bezel.
2 Follow the procedure listed in After working inside your system.
Installing and removing system components 55
Removing a drive carrier
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2Remove the front bezel.
3 Using the management software, prepare the drive for removal.
If the drive is online, the green activity or fault indicator ashes while the drive is turning o. When the drive indicators are o, the
drive is ready for removal. For more information, see the storage controller documentation.
CAUTION: Before attempting to remove or install a drive while the system is running, see the documentation for the
storage controller card to ensure that the host adapter is congured correctly to support drive removal and insertion.
CAUTION: To prevent data loss, ensure that your operating system supports drive installation. See the documentation
supplied with your operating system.
Steps
1 Press the release button to open the drive carrier release handle.
2 Holding the handle, slide the drive carrier out of the drive slot.
NOTE: If you are not replacing the drive immediately, install a drive blank in the empty drive slot to maintain proper
system cooling.
Figure 30. Removing a drive carrier
Next step
Replace the drive or a drive blank.
56 Installing and removing system components
Installing the drive carrier
Prerequisites
CAUTION: Before removing or installing a drive while the system is running, see the documentation for the storage controller
card to ensure that the host adapter is congured correctly to support drive removal and insertion.
CAUTION: Combining SAS and SATA drives in the same RAID volume is not supported.
CAUTION: When installing a drive, ensure that the adjacent drives are fully installed. Inserting a drive carrier and attempting to
lock its handle next to a partially installed carrier can damage the partially installed carrier's shield spring and make it unusable.
NOTE: Ensure that the drive carrier's release handle is in the open position before inserting the carrier into the slot.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation
supplied with your operating system.
CAUTION: When a replacement hot swappable drive is installed and the system is powered on, the drive automatically begins to
rebuild. Ensure that the replacement drive is blank or contains data that you wish to overwrite. Any data on the replacement
drive is immediately lost after the drive is installed.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
4 If installed, remove a drive blank.
Steps
1 Press the release button on the front of the drive carrier to open the release handle.
2 Insert the drive carrier into the drive slot and push until the drive connects with the backplane.
3 Close the drive carrier release handle to lock the drive in place.
NOTE: The procedure to install a 2.5-inch or a 3.5-inch drive are the same.
Figure 31. Installing a drive carrier
Installing and removing system components 57
Next steps
1Install the front bezel.
2 Follow the procedure listed in After working inside your system.
Removing the drive from the drive carrier
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
CAUTION: Mixing drive carriers from previous generations of PowerEdge servers is not supported.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
4Remove the drive carrier.
Steps
1 Using a Phillips #1 screwdriver, remove the screws from the slide rails on the drive carrier.
2 Lift the drive out of the drive carrier.
Figure 32. Removing the drive from the drive carrier
Next step
1Replace the drive into the drive carrier.
Installing the drive into the drive carrier
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
4Remove the drive carrier.
58 Installing and removing system components
CAUTION: Mixing drive carriers from other generations of PowerEdge servers is not supported.
Steps
1 Insert the drive into the drive carrier with the connector end of the drive towards the back of the carrier.
2 Align the screw holes on the drive with the screws holes on the drive carrier. When aligned correctly, the back of the drive is ush with
the back of the drive carrier.
3 Using a Phillips #1 screwdriver, replace the screws to secure the drive to the drive carrier.
NOTE: When installing a drive into the drive carrier, ensure that the screws are torqued to 4 in-pounds.
NOTE: Use the screws shipped with the drive carrier to secure the drive to the drive carrier.
Figure 33. Installing a drive into the drive carrier
Next steps
1Replace the drive carrier.
2Install the front bezel.
3 Follow the procedure listed in After working inside your system.
Removing a 2.5-inch drive from the 3.5-inch drive adapter
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove 3.5-inch drive adapter from the 3.5-inch drive carrier.
NOTE: A 2.5 inch hot swappable drive is installed in a 3.5-inch drive adapter, which is then installed in the 3.5-inch hot swappable
drive carrier.
Steps
1 Using a Phillips #1 screwdriver, remove the screws from the side of the 3.5-inch drive adapter.
2 Remove the drive from the 3.5-inch drive adapter.
Installing and removing system components 59
Figure 34. Removing a 2.5-inch drive from the 3.5-inch drive adapter
Next step
Replace a 2.5-inch drive into the 3.5-inch drive adapter.
Installing a 2.5-inch drive into the 3.5-inch drive adapter
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the screw holes on the 2.5-inch drive with the screw holes on the 3.5-inch drive adapter.
2 Using a Phillips #1 screwdriver, install the screws to secure the drive to the 3.5-inch drive adapter.
60 Installing and removing system components
Figure 35. Installing a 2.5-inch drive into the 3.5-inch drive adapter
Next steps
1Replace a 3.5-inch adapter into the 3.5-inch drive carrier.
2 Follow the procedure listed in After working inside your system.
Removing a 3.5-inch drive adapter from a 3.5-inch drive carrier
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the 3.5-inch drive carrier from the system.
Steps
1 Remove the screws from the rails on the drive carrier.
2 Lift the 3.5 inch drive adapter out of the drive carrier.
Installing and removing system components 61
Figure 36. Removing a 3.5-inch drive adapter from a 3.5-inch drive carrier
Next step
Replace a 3.5-inch adapter into a 3.5-inch drive carrier.
Installing a 3.5-inch adapter into a 3.5-inch drive carrier
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Insert the 3.5 inch drive adapter into the drive carrier with the connector end of the drive toward the back of the drive carrier.
2 Align the screw holes on the drive with the holes on the drive carrier.
3 Install the screws to secure the drive to the drive carrier.
62 Installing and removing system components
Figure 37. Installing a 3.5-inch drive adapter into the 3.5-inch drive carrier
Next steps
1Replace a 3.5-inch drive carrier into the system.
2 Follow the procedure listed in After working inside your system.
Optical drive and tape drives
Removing the optical or tape drive blank
Prerequisites
NOTE: The procedure to remove the optical drive blank is identical to removing a tape drive blank.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
Steps
1 Slide the release latch downwards to remove the drive blank.
2 Push the drive blank to slide it out of the drive bay.
Installing and removing system components 63
Figure 38. Removing the optical drive or tape drive blank
NOTE: Blanks must be installed on empty optical drive or tape drive slots to maintain FCC certication of the system.
The brackets also keep dust and dirt out of the system and aid in proper cooling and airow inside the system. Perform
the same steps to install blanks.
Next step
Replace the optical drive blank, or an optical drive, or a tape drive.
Installing the optical or tape drive blank
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2Remove the front bezel.
Steps
1 Align the guide on the drive blank with the slot on drive bay.
2 Slide the drive into the slot until the latch snaps into place.
64 Installing and removing system components
Figure 39. Installing the optical or tape drive blank
Next steps
1Install the front bezel.
2 Follow the procedure listed in After working inside your system.
Removing the optical drive
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
Steps
1 Disconnect the power and data cable connectors from the connectors on the optical drive.
NOTE: Observe the routing of the power and data cable inside the chassis as you remove them from the system board
and the drive. You must route these cables properly when you replace them to prevent them from being pinched or
crimped.
2 To remove the drive, slide the release latch downwards to release the drive.
3 Slide the drive out of the drive bay.
4 If you are not immediately replacing the tape drive, install the blank.
NOTE: Blanks must be installed on empty optical drive or tape drive slots to maintain FCC certication of the system.
The brackets also keep dust and dirt out of the system and aid in proper cooling and airow inside the system. Perform
the same steps to install blanks.
Installing and removing system components 65
Figure 40. Removing the optical drive
Next steps
1Replace the optical drive.
2 Follow the procedure listed in After working inside your system.
Installing the optical drive
Prerequisites
1 Ensure that you follow the procedure listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
4 If applicable, remove the optical drive blank.
NOTE: The procedure to remove the optical drive blank and the optical drive is similar.
Steps
1 Align the slide the optical drive into the slot until the latch clicks into place.
2 Connect the power and data cable connectors to the connectors on the optical drive.
3 Connect the power and data cable connectors to the backplane and the system board.
NOTE: Route the cables properly to prevent them from being pinched or crimped.
66 Installing and removing system components
Figure 41. Installing the optical drive
Next steps
1Install the front bezel.
2 Follow the procedure listed in After working inside your system.
Removing the tape drive
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
Steps
1 Disconnect the power and data cable connectors from the connectors on the tape drive.
NOTE: Observe the routing of the power and data cable connectors inside the chassis as you remove them from the
system board and the drive. You must route these cables properly when you replace them to prevent them from being
pinched or crimped.
2 Using the Phillips #2 screwdriver, remove the screw that secures the tape drive.
3 Push the release latch to release the drive.
4 Slide the drive out of the drive bay.
5 If you are not immediately replacing the tape drive, install the blank.
NOTE: Blanks must be installed on empty tape drive slots to maintain FCC certication of the system. The brackets also
keep dust and dirt out of the system and aid in proper cooling and airow inside the system. Perform the same steps to
install blanks.
Installing and removing system components 67
Figure 42. Removing the tape drive
Next steps
1Replace the tape drive.
2 Follow the procedure listed in After working inside your system.
Installing the tape drive
Prerequisites
1 Ensure that you follow the procedure listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
4 If applicable, remove the tape drive blank.
NOTE: The procedure to remove the tape drive blank and the tape drive is similar.
Steps
1 Align and slide the tape drive into the tape drive bay until it clicks into place.
2 Using the Phillips #2 screwdriver, secure the tape drive to the drive bay.
3 Connect the power and data cable connectors to the connectors on the tape drive.
4 Connect the power and data cable connectors to the backplane and the system board.
NOTE: Route the cables properly to prevent them from being pinched or crimped.
68 Installing and removing system components
Figure 43. Installing the tape drive
Next steps
1Install the front bezel.
2 Follow the procedure listed in After working inside your system.
Drive backplane
Drive backplane details
Your system supports the following backplane conguration:
• x8 SAS/SATA backplane for 3.5-inch drives
NOTE: The x8 backplane also supports up to eight 2.5-inch (SAS, SATA, or SSD) hot swappable drives that can be
installed in 3.5-inch drive adapters, which can be installed in the 3.5-inch drive carriers.
Installing and removing system components 69
Figure 44. x8 SAS/SATA backplane for 3.5-inch drives
1 ODD power connector (P1)
2 Backplane P4 power connector (BP_PWR)
3 Backplane sideband signal connector (BP_SIG)
4 Mini SAS SAS_A0
5 Mini SAS SAS_B0
Removing the drive backplane
Prerequisites
CAUTION: Note the number of each drive and temporarily label them before you remove the drive so that you can replace them
in the same location.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel.
4Remove all the drives.
CAUTION: To prevent damage to the drives and backplane, remove the drives from the system before removing the
backplane.
5Remove the air shroud.
Steps
1 Disconnect the data, signal, and power cables from the backplane.
2 Pull the release pin to disengage the backplane from the system.
3 Lift the backplane out of the system.
70 Installing and removing system components
Figure 45. Removing the drive backplane
Next steps
1Replace a drive backplane.
2 Follow the procedure listed in After working inside your system.
Installing the drive backplane
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the front bezel..
4Remove the air shroud.
5Remove all the drives.
Steps
1 Align the slots on the backplane with the hooks on the system.
2 Lower the drive backplane into the system until the release pin locks in place, securing the drive backplane to the system.
3 Connect the data, signal, and power cables to the backplane.
Installing and removing system components 71
Figure 46. Installing the drive backplane
Next steps
1Install the air shroud.
2Install the drives.
3Install the front bezel.
4 Follow the procedure listed in After working inside your system.
Backplane cable routing
Figure 47. Cable routing - 8 x 3.5-inch, SATA drive backplane
72 Installing and removing system components
Figure 48. Cable routing - 8 x 3.5-inch SAS/SATA drive backplane with PERC card
Four-slot drive blank
Systems with x8 drive backplanes congured for software RAID support only four drives. The remaining drive slots are pre-installed with
the four-slot drive blank, and cannot be upgraded for additional storage.
Removing a four-slot drive blank
Prerequisites
CAUTION: To maintain proper system cooling, all empty drive slots must have drive blanks installed.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
CAUTION: To prevent damage to the drives and backplane, you must remove the drives from the system before
removing the backplane.
CAUTION: Note the slot number of each drive and temporarily label the slots before removing the drives so that you
can replace them in the same locations.
3Remove the air shroud.
4Remove all the drives.
5Remove the drive backplane.
Steps
1 Using a screwdriver, push the release tabs on the corners of the blank from inside the system, to unlock the four-slot hard drive blank
from the chassis.
2 From the front of the system, pull the four-slot hard drive blank at the corners until it is free of the hard drive slot.
Installing and removing system components 73
Figure 49. Removing a four-slot drive blank
Next step
1Replace a four-slot drive blank.
Installing a four-slot drive blank
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Locate the drive slots numbered from four to seven.
2 Insert the four-slot drive blank into the drive slot, and push it until the release tabs click into place.
74 Installing and removing system components
Figure 50. Installing a four-slot drive blank
Next steps
1Install the drive backplane.
2Install the drives.
3Install the air shroud.
4 Follow the procedure listed in After working inside your system.
System memory
System memory guidelines
The system supports DDR4 unbuered DIMMs (UDIMMs). System memory holds the instructions that are executed by the processor.
Your system contains 4 memory sockets. Two memory channels are allocated to the processor.
Memory channels are organized as follows:
Installing and removing system components 75
Figure 51. System memory view
Table 4. Memory channels
Processor Channel 0 Channel 1
Processor 1 Slots A1, A3 Slots A2, A4
The following table shows the memory populations and operating frequencies for the supported congurations:
Table 5. Memory population
DIMM Type DIMMs Populated/
Channel Voltage Operating Frequency (in
MT/s)
Maximum DIMM Rank/Channel
UDIMM 1 1.2 V 2133, 2400, 2666 Dual rank or single rank
2 2133, 2400, 2666 Dual rank or single rank
76 Installing and removing system components
General memory module installation guidelines
To ensure optimal performance of your system, observe the following general guidelines when conguring your system memory. If your
system's memory congurations fail to observe these guidelines, your system might not boot, stop responding during memory
conguration, or operate with reduced memory.
The memory bus may operate at frequency can be 2666 MT/s, 2400 MT/s, or 2133 MT/s depending on the following factors:
• System prole selected (for example, Performance Optimized, or Custom [can be run at high speed or lower])
• Maximum supported DIMM speed of the processors
• Maximum supported speed of the DIMMs
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
The system supports Flexible Memory Conguration, enabling the system to be congured and run in any valid chipset architectural
conguration. The following are the recommended guidelines for installing memory modules:
• All DIMMs must be DDR4.
• A maximum of two dierent ranked DIMMs can be populated in a channel regardless of rank count.
• If memory modules with dierent speeds are installed, they will operate at the speed of the slowest installed memory module(s).
• Populate memory module sockets only if a processor is installed.
– For single-processor systems, sockets A1 to A4 are available.
– In Optimizer Mode, the DRAM controllers operate independently in the 64-bit mode and provide optimized memory performance.
Table 6. Memory population rules
Processor Conguration Memory population Memory population information
Single processor Optimizer (Independent channel)
population order
1, 2, 3, 4 Odd amount of DIMMs per processor
allowed.
• Populate all the sockets with white release tabs rst, followed by the black release tabs.
• When mixing memory modules with dierent capacities, populate the sockets with memory modules with the highest capacity rst.
For example, if you want to mix 8 GB and 16 GB memory modules, populate 16 GB memory modules in the sockets with white release
tabs and 8 GB memory modules in the sockets with black release tabs.
• Memory modules of dierent capacities can be mixed provided other memory population rules are followed.
For example, 8 GB and 16 GB memory modules can be mixed.
• Mixing of more than two memory module capacities in a system is not supported.
• Unbalanced memory congurations will result in a performance loss so always populate memory channels identically with identical
DIMMs for best performance.
• To ensure proper system cooling, memory module blanks must be installed in memory sockets that are not occupied.
Removing a memory module
Prerequisites
WARNING: Allow the memory modules to cool after you power o the system. Handle the memory modules by the edges and
avoid touching the components or metallic contacts on the memory module.
CAUTION: To ensure proper system cooling, when processor 1 and processor 2 are installed, memory module blanks must be
installed in memory sockets that are not occupied. Remove memory module blanks only if you intend to install memory modules
in those sockets.
1 Follow the safety guidelines listed in Safety instructions.
Installing and removing system components 77
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
Steps
1 Locate the appropriate memory module socket.
CAUTION: Handle each memory module only by the edges, ensuring not to touch the middle of the memory module or
metallic contacts.
2 Push the ejectors outward on both ends of the memory module socket to release the memory module from the socket.
3 Lift and remove the memory module from the system.
Figure 52. Removing a memory module
NOTE: If you are removing the memory module permanently, install a memory module blank. The procedure to install a
memory module blank is similar to that of the memory module.
Next step
1Replace the memory module.
Installing a memory module
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Install the air shroud.
Steps
1 Locate the appropriate memory module socket.
CAUTION: Handle each memory module only by the edges, ensuring not to touch the middle of the memory module or
metallic contacts.
CAUTION: To prevent damage to the memory module or the memory module socket during installation, do not bend or
ex the memory module. You must insert both ends of the memory module simultaneously.
2 Open the ejectors on the memory module socket outward to allow the memory module to be inserted into the socket.
3 Align the edge connector of the memory module with the alignment key of the memory module socket, and insert the memory module
in the socket.
CAUTION: Do not apply pressure at the center of the memory module. Apply pressure at both ends of the memory
module evenly.
78 Installing and removing system components
NOTE: The memory module socket has an alignment key that enables you to install the memory module in the socket in
only one orientation.
4 Press the memory module with your thumbs until the ejectors rmly click into place.
Figure 53. Installing a memory module
Next steps
1Install the air shroud.
2 Follow the procedure listed in After working inside your system.
3 Verify if the memory module has been installed properly, by pressing F2 and navigating to System Setup Main Menu > System BIOS >
Memory Settings . In the Memory Settings screen, the System Memory Size must reect the updated capacity of the installed
memory. If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory module
is rmly seated in the memory module socket. Run the system memory test in system diagnostics.
Cooling fan
Removing the internal cooling fan
Prerequisites
CAUTION: Never operate your system cover with the internal fan removed. The system can overheat and result in shutdown of
the system and loss of data.
CAUTION: Do not operate the system with the system cover removed for more than 5 minutes.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
Steps
1 Press the release tabs on the fan cable connector and disconnect it from the connector on the system board.
2 Holding the fan, press the release tab, and slide the fan out in the direction of the arrow marked on the fan.
Installing and removing system components 79
Figure 54. Removing the internal cooling fan
CAUTION: Do not remove or install the fan by holding the fan blades.
Next step
1Replace the internal fan.
Installing the internal cooling fan
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud
Steps
1 Align the four tabs on the fan with the four slots on the system wall.
2 Press and slide the fan into the slots until the release tab locks into place.
3 Connect the fan power cable connector to the connector on the system board.
80 Installing and removing system components
Figure 55. Installing the internal cooling fan
Next steps
1Install the air shroud.
2 Follow the procedure listed in After working inside your system.
Optional internal USB memory key
An optional USB memory key installed inside your system can be used as a boot device, security key, or mass storage device. To boot from
the USB memory key, congure the USB memory key with a boot image and then specify the USB memory key in the boot sequence in
System Setup.
An optional USB memory key can be installed in the internal USB 3.0 port.
NOTE: To locate the internal USB port on the system board, see the System board jumpers and connectors section.
Replacing the optional internal USB memory key
Prerequisites
CAUTION: To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory
key: 15.9 mm width x 57.15 mm length x 7.9 mm height.
1 Follow the safety guidelines listed in the Safety instructions.
2 Follow the procedure listed in the Before working inside your system.
3Remove the air shroud.
Steps
1 Locate the USB port or USB memory key on the system board.
To locate the USB port, see the System board jumpers and connectors section.
2 If installed, remove the USB memory key from the USB port.
3 Insert the replacement USB memory key into the USB port.
Installing and removing system components 81
Next steps
1 Follow the procedure that is listed in After working inside your system.
2 While booting, press F2 to enter System Setup and verify that the system detects the USB memory key.
Expansion cards
NOTE: A System Event Log (SEL) event is logged if an expansion card riser is not supported or missing. It does not prevent your
system from turning on. However, if a F1/F2 pause occurs with an error message, see
Troubleshooting expansion cards
section in
the
Dell EMC PowerEdge Servers Troubleshooting Guide
at Dell.com/poweredgemanuals.
Expansion card guidelines
The following table describes the installation order for installing expansion cards to ensure proper cooling and mechanical t. The expansion
cards with the highest priority must be installed rst by using the slot priority indicated.
NOTE: The expansion card slots are not hot-swappable.
Table 7. Expansion card slots supported on the system board
PCIe slot Processor Connection PCIe slot height PCIe slot length Slot width
Slot 1 (Gen3) Processor Full Height Half Length x8 link in x8 slot
Slot 2 (Gen3) Processor Full Height Half Length x8 link in x16 slot
Slot 3 (Gen3) Platform Controller Hub Full Height Half Length x1
Slot 4 (Gen3) Platform Controller Hub Full Height Half Length x4 link in x8 slot
Table 8. Expansion card installation order
Card
Priority
Category Card Type Form Factor Slot Priority Maximum
Allowed
1 Internal Adapter PowerEdge RAID Controller (PERC)
H730P+
Full Height 1,2 1
2 Internal Adapter PowerEdge RAID Controller (PERC)
H330+
Full Height 1,2 1
4 Internal Adapter HBA330 Full Height 1,2 1
6 External Adapter 12 GB SAS HBA Full Height 1,2 2
7 NIC 10 G NICs Dual Port (Intel) Full Height 1,2 2
8 NIC 10 GBT NICs (Intel) Full Height 1,2 2
9 HBA FC8 HBAs Full Height 1,2 2
10 Internal storage BOSS Full Height 1,2,4 1
11 Internal storage BOSS2 Full height 1,2,4 1
12 NIC 1 Gb NICs Quad Port (Broadcom) Full Height 1,2,4 3
13 NIC 1 Gb NICs Quad Port (Intel) Full Height 1,2,4 3
82 Installing and removing system components
Card
Priority
Category Card Type Form Factor Slot Priority Maximum
Allowed
14 NIC 1 Gb NICs Dual Port (Broadcom) Full Height 1,2,3,4 4
15 NIC 1 Gb NICs Quad Port (Intel) Full Height 1,2,4 3
Removing an expansion card
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
4 Disconnect any cables connected to the expansion card.
Steps
1 If installed, disconnect the data cables from the PERC card.
2 Press the expansion card retention latch and push the latch downwards to open it.
Figure 56. Removing an expansion card
Installing and removing system components 83
Figure 57. Removing the ller bracket
3 Hold the expansion card by its edges, and pull the card up to remove it from the expansion card connector and the system.
4 Install the ller bracket by performing the following steps:
a Align the expansion card ller bracket with the slot on the system.
b Push the expansion card ller bracket downwards until rmly seated.
c Close the blue expansion card retention latch by pushing the latch up until the latch snaps into place.
NOTE: Filler brackets must be installed in empty expansion-card slots to maintain FCC certication of the system. The
brackets also keep dust and dirt out of the system and aid in proper cooling and airow inside the system.
Next steps
1Replace an expansion card.
2Install the air shroud.
Installing an expansion card
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Open the expansion card retention latch.
2 Remove the existing expansion card or ller bracket from the slot.
NOTE: Store this bracket for future use. Filler brackets must be installed in empty expansion-card slots to maintain FCC
certication of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airow
inside the system.
3 Holding the card by its edges, align the card with the expansion card connector on the system board.
4 Insert the card rmly into the expansion card connector until the card is rmly seated.
5 Close the expansion card retention latch by pushing the latch down until the latch snaps into place.
84 Installing and removing system components
Figure 58. Installing an expansion card
Figure 59. Installing the ller bracket
6 Connect the data cables to the expansion card.
Next steps
1Install the air shroud.
2 Connect the cables to the expansion card.
3 Follow the procedure listed in After working inside your system.
Installing and removing system components 85
M.2 SSD module
Removing the M.2 SSD module
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
4 Remove the BOSS card.
NOTE: The procedure to remove the BOSS card is similar to removing an expansion card.
Steps
1 Using the Phillips #1 screwdriver, remove the screws securing the M.2 SSD module to the BOSS card.
2 Pull the M.2 SSD module to disconnect from the BOSS card connector.
Figure 60. Removing the M.2 SSD module
Next step
Replace the M.2 SSD module.
Installing the M.2 SSD module
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
86 Installing and removing system components
4 Remove the BOSS card.
NOTE: The procedure to remove the BOSS card is similar to the removing an expansion card.
Steps
1 Align the M.2 SSD module at an angle with the BOSS card connector.
2 Insert the M.2 SSD module until it is rmly seated in the BOSS card connector.
3 Using the Phillips #1 screwdriver, secure the M.2 SSD module on the BOSS card with the screw.
Figure 61. Installing the M.2 SSD module
Next steps
1 Install the BOSS card.
NOTE: The procedure to install the BOSS card is similar to removing an expansion card.
2Install the air shroud.
3 Follow the procedure listed in the After working inside your system.
Optional IDSDM or vFlash module
The IDSDM or vFlash module combines the IDSDM and/or vFlash features into a single module.
NOTE: The write-protect switch is on the IDSDM or vFlash module.
Removing the optional IDSDM or vFlash card
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
Installing and removing system components 87
4 If you are replacing the IDSDM/vFlash card, remove the MicroSD cards.
NOTE: Temporarily label each SD card with its corresponding slot number before removal. Reinstall the SD cards into
the corresponding slots.
Step
Holding the pull tab, lift the IDSDM/vFlash card out of the system.
Next step
NOTE: If you are replacing the IDSDM or vFlash module, remove the MicroSD cards.
1Replace the IDSDM/vFlash module.
Installing optional IDSDM or vFlash card
Prerequisites
1 Follow the safety guidelines listed in the Safety instructions.
2 Follow the procedure listed in the Before working inside your system.
3Remove the air shroud.
Steps
1 Locate the IDSDM/vFlash connector on the system board. To locate IDSDM/vFlash connector, see System board jumpers and
connectors section.
2 Align the IDSDM/vFlash card with the connector on the system board.
3 Push the IDSDM/vFlash card until it is rmly seated on the system board.
Figure 62. Installing optional IDSDM or vFlash card
Next steps
1Install the MicroSD cards.
NOTE: Reinstall the MicroSD cards into the same slots that are based on the labels you had marked on the cards
during removal.
2Install the air shroud.
88 Installing and removing system components
3 Follow the procedure that is listed in After working inside your system.
Removing the MicroSD card
Prerequisites
1 Follow the safety guidelines listed in the Safety instructions.
2 Follow the procedure listed in the Before working inside your system.
3Remove the air shroud.
4Remove the IDSDM or vFlash module.
Steps
1 Locate the MicroSD card slot on the vFlash/IDSDM module, and press the card to partially release it from the slot. To locate IDSDM/
vFlash module, see the System board jumpers and connectors section.
2 Hold the MicroSD card and remove it from the slot.
NOTE: Temporarily label each MicroSD card with its corresponding slot number after removal.
Figure 63. Removing the MicroSD card
Next step
1Replace the MicroSD cards.
Installing the MicroSD card
Prerequisites
1 Follow the safety guidelines listed in the Safety instructions.
Installing and removing system components 89
2 Follow the procedure listed in the Before working inside your system.
3Remove the air shroud.
4Remove the IDSDM or vFlash module.
NOTE: To use a MicroSD card with your system, ensure that the Internal SD Card Port is enabled in System Setup.
NOTE: If reinstalling, ensure that you install the MicroSD cards into the same slots based on the labels you had marked on the
cards during removal.
Steps
1 Locate the MicroSD card connector on the IDSDM/vFlash module. Orient the MicroSD card appropriately and insert the contact-pin
end of the card into the slot. To locate IDSDM/vFlash, see the System board jumpers and connectors section.
NOTE: The slot is keyed to ensure correct insertion of the card.
2 Press the card into the card slot to lock it into place.
Figure 64. Installing the MicroSD card
Next steps
1Install the IDSDM or vFlash module.
2 Follow the procedure listed in the After working inside your system.
Processor and heat sink
Removing the heat sink
Prerequisites
WARNING: The heat sink may be hot to touch for some time after the system is powered down. Allow the heat sink to cool
before removing it.
90 Installing and removing system components
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud
Steps
1 Using a Phillips #2 screwdriver, loosen the screws on the heat sink in the order below:
a Loosen the rst screw three turns.
b Loosen the second screw completely.
c Return to the rst screw and loosen it completely.
2 Repeat the procedure for the remaining screws.
3 Lift the heat sink from the system.
Figure 65. Removing the heat sink
Next steps
1 If you are removing a faulty heat sink, Replace the heat sink. Else, remove the processor.
2 Follow the procedure listed in After working inside your system.
Installing and removing system components 91
Removing the processor
Prerequisites
WARNING: The heat sink may be hot to touch for some time after the system has been powered down. Allow the heat sink to
cool before removing it.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the air shroud.
4Remove the heat sink.
Steps
1 Release the socket lever by pushing the lever down and out from under the tab on the processor shield.
2 Lift the lever until the processor shield is fully open.
3 Lift the processor from the socket.
Figure 66. Removing the processer
CAUTION: Do not touch the processor socket pins, they are fragile and can be permanently damaged. Be careful not to
bend the pins in the processor socket when removing the processor out of the socket.
Next steps
1Replace the processor into the processor and heat sink.
2 Follow the procedure listed in After working inside your system.
Installing the processor
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Align the pin1-indicator of the processor with the triangle on the system board.
CAUTION: Do not use force to seat the processor. When the processor is positioned correctly, it engages easily into the
socket.
2 Place the processor in the socket.
3 Close the processor shield by sliding it under the retention screw on the system board.
4 Lower the lever and push it under the tab to lock the processor shield.
92 Installing and removing system components
Figure 67. Installing the processor
Next steps
1Replace the heat sink.
2Replace the air shroud.
3 Follow the procedure listed in After working inside your system.
Installing the heat sink
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Install the processor.
Steps
1 If you are using an existing heat sink, remove the thermal grease from the heat sink by using a clean lint-free cloth.
2 Use the thermal grease syringe included with your processor kit to apply the grease in a thin spiral on the top of the processor as
shown in the following gure.
Installing and removing system components 93
Figure 68. Applying thermal grease on top of the processor
CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and contaminating the
processor socket.
NOTE: The thermal grease syringe is intended for one-time use only. Dispose of the syringe after you use it.
3 Align the screws on the heat sink with the standos on the system board.
CAUTION: When installing the heat sink, ensure that the airow arrow is pointed towards the rear of the
system.
4 Use a Phillips #2 screwdriver to tighten the screws to secure the heat sink to the system board.
a Tighten the rst screw three turns.
b Tighten the screw diagonally opposite to the screw you tightened.
c Return to the rst screw and tighten it completely.
5 Repeat the procedure for the remaining screws.
94 Installing and removing system components
Figure 69. Installing the heat sink
Next steps
1Replace the air shroud.
2 Follow the procedure listed in After working inside your system.
3 While booting, press F2 to enter System Setup and verify that the processor information matches the new system conguration.
4 Run the system diagnostics to verify that the new processor operates correctly.
Power supply unit
NOTE: For more information, see the Technical specications section.
Removing the power supply unit blank
Prerequisite
1 Follow the safety guidelines listed in Safety instructions.
Step
Remove the PSU blank in the bay by pulling the blank outward.
Installing and removing system components 95
CAUTION: To ensure proper system cooling, the PSU blank must be installed in the second PSU bay in a non-redundant
conguration. Remove the PSU blank only if you are installing a second PSU.
Figure 70. Removing the power supply unit blank
Next step
Install the PSU or PSU blank.
Installing the power supply unit blank
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
NOTE: Install the power supply unit (PSU) blank only in the second PSU bay.
2Remove the PSU.
Step
Align the PSU blank with the PSU slot and push it into the PSU slot until it clicks into place.
96 Installing and removing system components
Figure 71. Installing the power supply unit blank
Removing a redundant AC power supply unit
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Disconnect the power cable from the power outlet and from the PSU you want to remove, then remove the cable from the strap on
the PSU handle.
Step
Press the orange release latch and slide the PSU out of the system using the PSU handle.
Installing and removing system components 97
Figure 72. Removing a redundant power supply unit
Next step
Install the PSU or PSU blank.
Installing a redundant AC power supply unit
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 For systems that support redundant PSU, ensure that both the PSUs are of the same type and have the same maximum output
power.
NOTE: The maximum output power (shown in watts) is listed on the PSU label.
3Remove the PSU blank.
Step
Slide the PSU into the system until the PSU is fully seated.
98 Installing and removing system components
Figure 73. Installing a redundant power supply unit
Next step
1 Connect the power cable to the PSU, and plug the cable into a power outlet.
CAUTION: When connecting the power cable to the PSU, secure the cable to the PSU with the strap.
NOTE: When installing, hot swapping, or hot adding a new PSU, wait for 15 seconds for the system to recognize the
PSU and determine its status. The PSU redundancy may not occur until discovery is complete. The PSU status
indicator turns green to indicate that the PSU is functioning properly.
Removing a cabled power supply unit
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Disconnect all the power cables of the PSU from the system board and the drive backplane.
2 Remove the screw securing the PSU to the system and slide the PSU out of the PSU bay in the chassis.
Installing and removing system components 99
Figure 74. Removing a cabled power supply unit
Next step
1Replace a cabled PSU.
Installing a cabled power supply unit
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Unpack the replacement power supply unit (PSU).
Steps
1 Slide the PSU into the PSU bay in the chassis until the PSU is fully seated.
2 Tighten the screw to secure the PSU to the system.
3 Connect all the power cables from the PSU to the system board and the drive backplane.
100 Installing and removing system components
Figure 75. Installing a cabled power supply unit
Next step
1 Follow the procedure listed in After working inside your system.
Power interposer board
Removing the power interposer board
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the power supply units (PSUs).
CAUTION: To prevent damage to the power interposer board, you must remove the power supply units or PSU blank
from the system before removing the power interposer board (PIB).
Steps
1 Disconnect all cables connected from the power interposer board (PIB) to the system board, and remove the cables from the cable
retention brackets.
NOTE: Observe the routing of the cable as you remove it from the system. Route the cable properly when you replace it
to prevent the cable from being pinched or crimped.
2 Pressing the release latch on the PIB, lift the PIB to release it from the hooks on the PSU cage.
3 Lift the board and slide it out at an angle to disengage the guide pins on the board.
Installing and removing system components 101
Figure 76. Removing the power interposer board
Next step
1Replace the power interposer board (PIB).
Installing the power interposer board
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3Remove the power supply units.
4Remove the air shroud.
Steps
1 Align the slots on the power interposer board (PIB) with the hooks on the power supply unit (PSU) cage and slide the PIB until it
snaps into place.
2 Route the P3 power cable through the securing clip on the system board and connect the power cable to the drive backplane.
Figure 77. Installing the power interposer board
102 Installing and removing system components
Next steps
1Install the air shroud
2Replace the PSUs.
3 Follow the procedure that is listed in After working inside your system.
System battery
Replacing the system battery
Prerequisites
WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or
equivalent type that the manufacturer recommends. Discard used batteries according to the manufacturer's instructions. See
the safety instructions that came with your system for more information.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Locate the system battery on the system.
2 To remove the battery:
a Push the battery toward the positive side of the battery until the battery disengages from the connector.
b Lift the battery away from the system.
Figure 78. Removing the system battery
3 To install a new system battery:
a Hold the battery with the + sign facing the positive side of the battery connector.
NOTE: Ensure that you do not push the battery clip more than 3.2 millimeters or you might risk damaging
the part.
b Insert the battery down into the connector until the battery snaps into place.
Installing and removing system components 103
Figure 79. Installing the system battery
Next steps
1 Follow the procedure listed in After working inside your system.
2 Enter the System Setup to conrm that the battery is operating properly.
3 Enter the correct time and date in the System Setup's Time and Date elds.
4 Exit the System Setup.
5 To test the newly installed battery, remove the system from the enclosure, for at least an hour.
6 Reinstall the system into the enclosure, after an hour.
7 Enter the System Setup and if the time and date are still incorrect, see Getting help.
System board
Removing the system board
Prerequisites
CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may be prompted to create a
recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you replace this system
board, you must supply the recovery key when you restart your system or program before you can access the encrypted data on
your hard drives.
CAUTION: Do not attempt to remove the TPM plug-in module from the system board. Once the TPM plug-in module is installed,
it is cryptographically bound to that specic system board. Any attempt to remove an installed TPM plug-in module breaks the
cryptographic binding, and it cannot be reinstalled or installed on another system board.
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
3 Remove the following:
aAir shroud
bInternal cooling fan
cExpansion cards, if installed
104 Installing and removing system components
dvFlash/IDSDM module
eInternal USB key, if installed
fProcessors and heat sink
CAUTION: To prevent damage to the processor pins when replacing a faulty system board, ensure that you
cover the processor socket with the processor protective cap.
gMemory modules
Steps
1 Disconnect all cables from the system board.
CAUTION: Take care not to damage the system identication button while removing the system board from the system.
CAUTION: Do not lift the system board by holding a memory module, processor, or other components.
2 Using a Phillips #2 screwdriver, remove the screws that secure the system board to the system.
Figure 80. Removing the screws from the system board
3 Holding the post, incline the system board at an angle, and lift the system board out of the system.
Figure 81. Removing the system board
Installing and removing system components 105
Next step
1Replace or install the system board.
Installing the system board
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Unpack the new system board assembly.
CAUTION: Do not lift the system board by holding a memory module, processor, or other components.
CAUTION: Take care not to damage the system identication button while placing the system board into the system.
2 Holding the post, incline the system board, and lower the system board into the system.
3 Holding the system board holder, push the system board toward the back of the system such that the ports on the system board align
with the corresponding slots on the system.
4 Using the Phillips #2 screwdriver, secure the system board to the system with screws.
Figure 82. Installing the system board
106 Installing and removing system components
Next steps
1 Replace the following:
aTrusted Platform Module (TPM)
NOTE: The TPM plug-in module is attached to the system board and cannot be removed. A replacement
TPM plug-in module is provided for all system board replacements, where a TPM plug-in module was
installed.
bMemory modules
cProcessors and heat sink
dInternal USB key, if installed
evFlash/IDSDM module
fExpansion cards, if installed
gInternal cooling fan
hAir shroud
2 Reconnect all cables to the system board.
NOTE: Ensure that the cables inside the system are routed along the chassis wall and secured by using the cable
securing bracket.
3 Follow the procedure that is listed in Safety instructions.
4 Ensure that you:
a Use the Easy Restore feature to restore the Service Tag. For more information, see the Restoring the system using Easy Restore
section.
b If the Service Tag is not backed up in the backup ash device, enter the Service Tag manually. For more information, see the
Manually update the Service Tag section.
c Update the BIOS and iDRAC versions.
d Reenable the Trusted Platform Module (TPM). For more information, see the Upgrading the Trusted Platform Module section.
5 Import your new or existing iDRAC Enterprise license.
For more information, see iDRAC User's Guide, at Dell.com/poweredgemanuals
Restoring the system using Easy Restore
The easy restore feature enables you to restore your service tag, license, UEFI conguration, and the system conguration data after
replacing the system board. All data is backed up in a backup ash device automatically. If BIOS detects a new system board, and the
service tag in the backup ash device, BIOS prompts the user to restore the backup information.
Below is a list of options available:
• Restore the service tag, license, and diagnostics information, press Y
• Navigate to the Lifecycle Controller based restore options, press N.
• Restore data from a previously created Hardware Server Prole, press F10
NOTE: When the restore process is complete, BIOS prompts to restore the system conguration
data.
• To restore the system conguration data, press Y
• To use the default conguration settings, press N
NOTE: After the restore process is complete, system reboots.
Manually update the Service Tag
After replacing a system board, if Easy Restore fails, follow this process to manually enter the Service Tag, using System Setup.
About this task
If you know the system service tag, use the System Setup menu to enter the service tag.
Installing and removing system components 107
Steps
1 Power on the system.
2 To enter the System Setup, press F2.
3 Click Service Tag Settings.
4 Enter the service tag.
NOTE: You can enter the service tag only when the Service Tag eld is empty. Ensure that you enter the correct service
tag. Once the service tag is entered, it cannot be updated or changed.
5 Click OK.
Trusted Platform Module
Upgrading the Trusted Platform Module
Prerequisite
NOTE:
• Ensure that your operating system supports the version of the TPM module being installed.
• Ensure that you download and install the latest BIOS rmware on your system.
• Ensure that the BIOS is congured to enable UEFI boot mode.
About this task
CAUTION: Once the TPM plug-in module is installed, it is cryptographically bound to that specic system board. Any attempt to
remove an installed TPM plug-in module breaks the cryptographic binding, the removed TPM cannot be reinstalled or installed on
another system board.
Removing the TPM
1 Locate the TPM connector on the system board.
2 Press to hold the module down and remove the screw using the security Torx 8-bit shipped with the TPM module.
3 Slide the TPM module out from its connector.
4 Push the plastic rivet away from the TPM connector and rotate it 90° counterclockwise to release it from the system board.
5 Pull the plastic rivet out of its slot on the system board.
Installing the TPM
Steps
1 To install the TPM, align the edge connectors on the TPM with the slot on the TPM connector.
2 Insert the TPM into the TPM connector such that the plastic rivet aligns with the slot on the system board.
3 Press the plastic rivet until the rivet snaps into place.
4 Replace the screw that secures the TPM to the system board.
108 Installing and removing system components
Figure 83. Installing the TPM
Next steps
1Replace the system board.
2 Follow the procedure listed in After working inside your system.
3 To verify if the memory module has been installed properly, press F2 and navigate to System Setup Main Menu > System BIOS >
Memory Settings. In the Memory Settings screen, the System Memory Size must reect the updated capacity of the installed
memory.
4 If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory module is rmly
seated in the memory module socket.
5 Run the system memory test in system diagnostics.
Initializing TPM for BitLocker users
1 Initialize the TPM.
For more information, see initializing the TPM for Intel TXT users.
2 The TPM Status changes to Enabled, Activated.
Initializing the TPM 1.2 for TXT users
1 While booting your system, press F2 to enter System Setup.
2 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
3 From the TPM Security option, select On with Preboot Measurements.
4 From the TPM Command option, select Activate.
5 Save the settings.
6 Restart your system.
7 Enter System Setup again.
8 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
9 From the Intel TXT option, select On.
Initializing the TPM 2.0 for TXT users
1 While booting your system, press F2 to enter System Setup.
2 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
Installing and removing system components 109
3 From the TPM Security option, select On.
4 Save the settings.
5 Restart your system.
6 Enter System Setup again.
7 On the System Setup Main Menu screen, click System BIOS > System Security Settings.
8 Select the TPM Advanced Settings option.
9 From the TPM2 Algorithm Selection option, select SHA256, then go back to System Security Settings screen.
10 On the System Security Settings screen, from the Intel TXT option, select On.
11 Save the settings.
12 Restart your system.
Control panel
Removing the control panel assembly
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your system.
Steps
1 Using the Phillips #2 screwdriver, remove the screw that secures control panel to the system.
2 Disconnect the control panel cable and the control panel USB cable from the system board.
CAUTION: Do not use excessive force when removing the control panel cables as it can damage the connectors.
3 Slide the control panel out of the system.
4 To remove the information tag, perform the following steps:
a Locate and press the tabs on the information tag.
b Push the information tag out of the slot to remove it from the control panel.
Figure 84. Removing the control panel assembly
110 Installing and removing system components
NOTE: Retain the information tag to replace it in the new control panel.
Next step
1Replace the control panel assembly.
Installing the control panel assembly
Prerequisite
Follow the safety guidelines listed in Safety instructions.
Steps
1 Replace the blank information tag in the new control panel with the information tag retained from the old control panel.
2 To install the information tag, push the information tag into the control-panel slot.
3 Connect the control panel cable and the control panel USB cable to the control panel assembly.
4 Align and insert the control panel into the control panel slot in the system.
5 Secure the control panel to the system by using the screw.
6 Connect the control panel cable and the control panel USB cable to the system board.
Figure 85. Installing the control panel assembly
Next step
1 Follow the procedure listed in After working inside your system.
Installing and removing system components 111
Jumpers and connectors
This topic provides specic information about the jumpers. It also provides some basic information about jumpers and switches and
describes the connectors on the various boards in the system. Jumpers on the system board help to disable the system and setup
passwords. You must know the connectors on the system board to install components and cables correctly.
Topics:
• System board jumpers and connectors
• System board jumper settings
• Disabling forgotten password
6
112 Jumpers and connectors
System board jumpers and connectors
Figure 86. T340 system board jumpers and connectors
Table 9. System board connectors
Item Connector Description
1 FP_USB Front panel USB connector
2 PIB_CONN Power interposer board signal connector
3 BP_SIG Backplane signal connector
4 Slot 1 PCIE_G3_X8 CPU PCIe card connector 1
5 Slot 2 PCIE_G3_X8 CPU PCIe card connector 2
6 Slot 3 PCIE_G3_X1 PCH PCIe card connector 3
7 LEDs (7) System board diagnostic LED indicators
Jumpers and connectors 113
Item Connector Description
8 INT_USB_3.0 Internal USB
9 Slot 4 PCIE_G3_X4 PCH PCIe card connector 4
10 T_INTRUSION Intrusion switch connector
11 SYS_FAN Fan
12 P2 CPU power connector P2
13 A1, A2, A3, A4 Memory module sockets
14 P1 System power P1
15 SATA 0-3 Mini SAS connector
16 SATA_ODD/SSD Optical disk drive connector
17 PWR_EVNT Power event
18 J_SATA_2 SATA connector 2
19 CPU Processor
20 NVRAM_CLR NVRAM password Jumper
21 TPM Trusted Platform Module connector
22 PWRD_EN Reset BIOS password jumper
23 IDSDM+ vFlash IDSDM+VFlash connector
24 Coin cell battery Coin cell battery
25 CTRL_PNL Control panel
System board jumper settings
For information on resetting the password jumper to disable a password, see the Disabling a forgotten password section.
Table 10. System board jumper settings
Jumper Setting Description
PWRD_EN The BIOS password feature is enabled.
The BIOS password feature is disabled. iDRAC local access is
unlocked at next AC power cycle. iDRAC password reset is enabled
in F2 iDRAC settings menu.
NVRAM_CLR The BIOS conguration settings are retained at system boot.
The BIOS conguration settings are cleared at system boot.
114 Jumpers and connectors
Disabling forgotten password
The software security features of the system include a system password and a setup password. The password jumper enables or disables
password features and clears any password(s) currently in use.
Prerequisite
CAUTION: Many repairs may only be done by a certied service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Steps
1 Power o the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2 Remove the system cover.
3 Move the jumper on the system board jumper from pins 2 and 4 to pins 4 and 6.
4 Install the system cover.
The existing passwords are not disabled (erased) until the system boots with the jumper on pins 4 and 6. However, before you assign a
new system and/or setup password, you must move the jumper back to pins 2 and 4.
NOTE: If you assign a new system and/or setup password with the jumper on pins 4 and 6, the system disables the new
password(s) the next time it boots.
5 Reconnect the system to its electrical outlet and power on the system, including any attached peripherals.
6 Power o the system, including any attached peripherals, and disconnect the system from the electrical outlet.
7 Remove the system cover.
8 Move the jumper on the system board jumper from pins 4 and 6 to pins 2 and 4.
9 Install the system cover.
10 Reconnect the system to its electrical outlet and power on the system, including any attached peripherals.
11 Assign a new system and/or setup password.
Jumpers and connectors 115
Technical specications
The technical and environmental specications of your system are outlined in this section.
Topics:
• Chassis dimensions
• System weight
• Processor specications
• Supported operating systems
• PSU specications
• Cooling fan specications
• System battery specications
• Expansion card specications
• Memory specications
• Storage controller specications
• Drive specications
• Ports and connectors specications
• Video specications
• Environmental specications
7
116 Technical specications
Chassis dimensions
Figure 87. Chassis dimensions
Table 11. Dell EMC PowerEdge T340 chassis dimensions
Xa Xb Ya Yb Yc Za Zb Zc
218 mm (8.58
inches)
307.9 mm
(12.12 inches)
430.3 mm
(16.94 inches)
443.3 mm
(17.45 inches)
471.3 mm
(18.56 inches)
With bezel: 14.1
mm (0.56
inches)
545.4 mm
(21.47 inches)
589.1 mm
(23.19 inches)
System weight
Table 12. Dell EMC PowerEdge T340 system chassis weight
System conguration Maximum weight (with all drives/SSDs)
8 x 3.5-inch drives 25.25 Kg (55.67 lb)
Processor specications
Table 13. Dell EMC PowerEdge T340 processor specications
Supported processor Number of processors supported
Intel Xeon Scalable Processor One
Technical specications 117
Supported operating systems
The Dell EMC PowerEdge T340 supports the following operating systems:
• Canonical Ubuntu LTS
• Citrix XenServer
• Microsoft Windows Server
• Red Hat Enterprise Linux
• SUSE Linux Enterprise Server
• VMware ESXi
NOTE: For more information, go to Dell.com/ossupport.
NOTE: For more information about the specic versions and additions, go to https://www.dell.com/support/home/Drivers/
SupportedOS/poweredge-t340.
PSU specications
The Dell EMC PowerEdge T340 system supports up to two AC power supply units (PSUs).
Table 14. Dell EMC PowerEdge T340 PSU specications
PSU Class Heat
dissipation
(maximum)
Frequency Voltage AC DC Current
High line
(100–240 V)
Low line
(100–120 V)
495 W AC Platinum 1908 BTU/hr 50/60 Hz 100–240 V
AC,
autoranging
495 W NA N/A 6.5 A–3 A
350 W AC Bronze 1405 BTU/hr 50/60 Hz 100–240 V
AC,
autoranging
350 W NA N/A 5.5 A–3 A
Cooling fan specications
The Dell EMC PowerEdge T340 system supports one system cooling fan.
NOTE: When selecting or upgrading the system conguration, to ensure optimum power utilization, verify the system power
consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
System battery specications
The Dell EMC PowerEdge T340 system supports CR 2032 3.0-V lithium coin cell system battery.
Expansion card specications
The Dell EMC PowerEdge T340 system supports up to four PCI express (PCIe) Generation 3.
118 Technical specications
Table 15. Expansion card slots supported on the system board
PCIe slot Processor Connection PCIe slot height PCIe slot length Slot width
Slot 1 (Gen3) Processor Full Height Half Length x8 link in x8 slot
Slot 2 (Gen3) Processor Full Height Half Length x8 link in x16 slot
Slot 3 (Gen3) Platform Controller Hub Full Height Half Length x1
Slot 4 (Gen3) Platform Controller Hub Full Height Half Length x4 link in x8 slot
NOTE: The expansion cards are not hot swappable.
Memory specications
The Dell EMC PowerEdge T340 system supports the following memory specications for optimized operation:
Table 16. Memory specications
DIMM type DIMM rank DIMM capacity Minimum RAM Maximum RAM
UDIMM Single rank 8 GB 8 GB 32 GB
16 GB 16 GB 64 GB
Dual rank 8 GB 8 GB 32 GB
16 GB 16 GB 64 GB
Storage controller specications
The Dell EMC PowerEdge T340 system supports the following controller cards:
Table 17. Dell EMC PowerEdge T340 system controller cards
Internal controllers External controllers
• PERC H730P
• PERC H330
• S140
• HBA330
• 12Gbps SAS Ext. HBA
Drive specications
Drives
The Dell EMC PowerEdge T340 system supports:
• 4 x 3.5-inch SAS, SATA drives, 2.5-inch hotplug drives
• 8 x 3.5-inch SAS, SATA drives, 2.5-inch hotplug drives
NOTE: 2.5-inch drives in 3.5-inch carriers are supported for SAS, and SATA SSD drives.
Technical specications 119
Optical drives
The Dell EMC PowerEdge T340 system supports the following optical drives.
Table 18. Supported optical drive type
Supported drive type Supported number of drives
Dedicated SATA DVD-ROM drive or DVD +/-RW drive One
Tape drives
The Dell EMC PowerEdge T340 system supports up to two dedicated 5.25-inch tape drives.
Ports and connectors specications
USB ports specications
Table 19. Dell EMC PowerEdge T340 system USB port specications
Front panel Back panel Internal USB
• One USB 3.0-compliant port
• One iDRAC USB MGMT port (USB
2.0)
NOTE: The micro USB
2.0 compliant port can
only be used as an iDRAC
Direct or a management
port.
• Two USB 3.0-compliant ports
• Four USB 2.0-compliant ports
• One internal USB 3.0-compliant port
NIC ports specications
The Dell EMC PowerEdge T340 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports that are located
on the back panel.
Serial connector specications
The Dell EMC PowerEdge T340 system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal
Equipment (DTE), 16550-compliant.
VGA ports specication
The Dell EMC PowerEdge T340 system supports two 15-pin VGA ports, one each, on the front and back of the system.
120 Technical specications
IDSDM module
The Dell EMC PowerEdge T340 system supports optional Internal Dual SD module (IDSDM) module.
The module supports three microSD cards; two cards for IDSDM and one card for vFlash. In 14th generation of PowerEdge servers, the
IDSDM or vFlash module is combined into a single card module, and is available in the following congurations:
• vFlash or
• vFlash and IDSDM
Table 20. Supported microSD card storage capacity
IDSDM card vFlash card
• 16 GB
• 32 GB
• 64 GB
• 16 GB
NOTE: There are two dip switches on the IDSDM or vFlash module for write-protection.
NOTE: One IDSDM card slot is dedicated for redundancy.
NOTE: Use Dell EMC branded microSD cards that are associated with the IDSDM or vFlash congured systems.
Video specications
The Dell EMC PowerEdge T340 system supports Matrox G200eR2 graphics card with 16 MB capacity.
Table 21. Supported video resolution options
Resolution Refresh rate Color depth (bits)
640x480 60, 70 8, 16, 24
800x600 60, 75, 85 8, 16, 24
1024x768 60, 75, 85 8, 16, 24
1152x864 60, 75, 85 8, 16, 24
1280x1024 60, 75 8, 16, 24
Environmental specications
NOTE: For additional information about environmental certications, refer to the
Product Environmental Datasheet
located with
the Manuals & Documents on Dell.com/support/home.
Table 22. Temperature specications
Temperature Specications
Storage -40–65°C (-40–149°F)
Continuous operation (for altitude less than 950 m or
3117 ft)
10–35°C (50–95°F) with no direct sunlight on the equipment
Technical specications 121
Temperature Specications
Fresh air For information about fresh air, see the Expanded operating temperature section.
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Table 23. Relative humidity specications
Relative humidity Specications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point.
Atmosphere must be noncondensing at all times.
Operating 10% to 80% RH with 29°C (84.2°F) maximum dew point.
Table 24. Maximum vibration specications
Maximum vibration Specications
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Table 25. Maximum shock pulse specications
Maximum shock pulse Specications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z
axis of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z
axis (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 26. Maximum altitude specications
Maximum altitude Specications
Operating 3048 m (10,000 ft)
Storage 12,000 m (39,370 ft)
Table 27. Operating temperature derating specications
Operating temperature derating Specications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft), above 950 m (3,117
ft).
35–40°C (95–104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft), above 950 m (3,117
ft).
40–45°C (104–113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft), above 950 m (3,117
ft).
122 Technical specications
Standard operating temperature
Table 28. Standard operating temperature specications
Standard operating temperature Specications
Continuous operation (for altitude less than 950 m or 3117
ft)
10–35°C (50–95°F) with no direct sunlight on the equipment.
Expanded operating temperature
Table 29. Expanded operating temperature specications
Expanded operating temperature Specications
Continuous operation 5°C–40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating temperature
(10°C–35°C), the system can operate continuously in
temperatures as low as 5°C and as high as 40°C.
For temperatures 35°C– 40°C, derate maximum allowable
temperature by 1°C per 175 m (1°F per 319 ft) above 950 m (3,1171
ft).
≤ 1% of annual operating hours -5°C–45°C at 5% to 90% RH with 29°C dew point.
NOTE: Outside the standard operating temperature
(10°C–35°C), the system can operate down to -5°C or
up to 45°C for a maximum of 1% of its annual operating
hours.
For temperatures 40°C– 45°C, derate maximum allowable
temperature by 1°C per 125 m (1°F per 228 ft) above 950 m (3.117
ft).
NOTE: When operating in the expanded temperature range, the performance of the system may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the System
Event Log.
Expanded operating temperature restrictions
• Do not perform a cold startup of the system below 5°C.
• The operating temperature specied is for a maximum altitude of 950 m for Fresh Air cooling.
• Two redundant power supply units are required.
• Cooling redundancy is not supported due to single fan only in system.
• Support up to 80 W processor.
• One system fan is required.
• Non-Dell qualied peripheral cards and/or peripheral cards greater than 25 W are not supported.
• GPU is not supported.
Technical specications 123
• Tape backup unit is supported.
Particulate and gaseous contamination specications
The following table denes the limitations that help avoid any damages to the IT equipment and/or, or both failure from particulate and
gaseous contamination. If the levels of particulate or gaseous pollution exceed the specied limitations and results in equipment damage or
failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.
Table 30. Particulate contamination specications
Particulate contamination Specications
Air ltration Data center air ltration as dened by ISO Class 8 per ISO 14644-1
with a 95% upper condence limit.
NOTE: This condition applies to data center environments
only. Air ltration requirements do not apply to IT
equipment designed to be used outside a data center, in
environments such as an oce or factory oor.
NOTE: Air entering the data center must have MERV11 or
MERV13 ltration.
Conductive dust Air must be free of conductive dust, zinc whiskers, or other
conductive particles.
NOTE: This condition applies to data center and non-data
center environments.
Corrosive dust • Air must be free of corrosive dust.
• Residual dust present in the air must have a deliquescent point
less than 60% relative humidity.
NOTE: This condition applies to data center and non-data
center environments.
Table 31. Gaseous contamination specications
Gaseous contamination Specications
Copper Coupon Corrosion <300 Å/month per Class G1 as dened by ANSI/ISA71.04-1985.
Silver Coupon Corrosion <200 Å/month as dened by AHSRAE TC9.9.
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
124 Technical specications
System diagnostics and indicator codes
The diagnostic indicators on the system front panel display system status during system startup.
Topics:
• System health and system ID indicator codes
• iDRAC Direct LED indicator codes
• NIC indicator codes
• Non-redundant cabled power supply unit indicator codes
• Power supply unit indicator codes
• Drive indicator codes
• Using system diagnostics
System health and system ID indicator codes
The system health and system ID indicator is located on the front panel of your system.
Figure 88. System health and system ID indicator
Table 32. System health and system ID indicator codes
System health and system ID indicator
code
Condition
Solid blue Indicates that the system is turned on, system is healthy, and system ID mode is not active.
Press the system health and system ID button to switch to system ID mode.
Blinking blue Indicates that the system ID mode is active. Press the system health and system ID button to
switch to system health mode.
Solid amber Indicates that the system is in fail-safe mode. If the problem persists, see the Getting help
section.
Blinking amber Indicates that the system is experiencing a fault. Check the System Event Log for specic
error messages. For information about the event and error messages generated by the system
rmware and agents that monitor system components, see the Error Code Lookup page, at
qrl.dell.com
iDRAC Direct LED indicator codes
The iDRAC Direct LED indicator lights up to indicate that the port is connected and is being used as a part of the iDRAC subsystem.
You can congure iDRAC Direct by using a USB to micro USB (type AB) cable, which you can connect to your laptop or tablet. The
following table describes iDRAC Direct activity when the iDRAC Direct port is active:
8
System diagnostics and indicator codes 125
Table 33. iDRAC Direct LED indicator codes
iDRAC Direct LED
indicator code
Condition
Solid green for two seconds Indicates that the laptop or tablet is connected.
Flashing green (on for two
seconds and o for two
seconds)
Indicates that the laptop or tablet connected is recognized.
Powers o Indicates that the laptop or tablet is unplugged.
NIC indicator codes
Each NIC on the back of the system has indicators that provide information about the activity and link status. The activity LED indicator
indicates if data is owing through the NIC, and the link LED indicator indicates the speed of the connected network.
Figure 89. NIC indicator codes
1Link LED indicator 2 Activity LED indicator
Table 34. NIC indicator codes
Status Condition
Link and activity indicators are o. The NIC is not connected to the network.
Link indicator is green, and activity indicator is blinking
green.
The NIC is connected to a valid network at its maximum port speed, and
data is being sent or received.
Link indicator is amber, and activity indicator is blinking
green.
The NIC is connected to a valid network at less than its maximum port
speed, and data is being sent or received.
Link indicator is green, and activity indicator is o. The NIC is connected to a valid network at its maximum port speed, and
data is not being sent or received.
Link indicator is amber, and activity indicator is o. The NIC is connected to a valid network at less than its maximum port
speed, and data is not being sent or received.
Link indicator is blinking green, and activity is o. NIC identify is enabled through the NIC conguration utility.
Non-redundant cabled power supply unit indicator
codes
Press the self-diagnostic button to perform a quick health check on the non-redundant cabled power supply unit (PSU) of the system.
126 System diagnostics and indicator codes
Figure 90. Non-redundant cabled AC PSU status indicator and self-diagnostic button
1 Self-diagnostic button 2 AC PSU status indicator
Table 35. Non-redundant AC PSU status indicator
Power Indicator Pattern Condition
Not lit Power is not connected or PSU is faulty.
Green A valid power source is connected to the PSU and the PSU is operational.
Power supply unit indicator codes
AC power supply units (PSUs) have an illuminated translucent handle that serves as an indicator. The indicator shows whether power is
present or if a power fault has occurred.
Figure 91. AC PSU status indicator
1AC PSU status indicator/handle
Table 36. AC PSU status indicator codes
Power indicator codes Condition
Green A valid power source is connected to the PSU and the PSU is operational.
Blinking amber Indicates a problem with the PSU.
Not illuminated Power is not connected to the PSU.
Blinking green When the rmware of the PSU is being updated, the PSU handle blinks green.
System diagnostics and indicator codes 127
Power indicator codes Condition
CAUTION: Do not disconnect the power cord or unplug the PSU when updating rmware. If
rmware update is interrupted, the PSUs do not function.
Blinking green and turns o When hot-plugging a PSU, the PSU handle blinks green ve times at a rate of 4 Hz and turns o. This
indicates a PSU mismatch with respect to eciency, feature set, health status, or supported voltage.
CAUTION: If two PSUs are installed, both the PSUs must have the same type of label; for
example, Extended Power Performance (EPP) label. Mixing PSUs from previous generations of
PowerEdge servers is not supported, even if the PSUs have the same power rating. This results
in a PSU mismatch condition or failure to power on the system.
CAUTION: When correcting a PSU mismatch, replace only the PSU with the blinking indicator.
Swapping the PSU to make a matched pair can result in an error condition and unexpected
system shutdown. To change from a high output conguration to a low output conguration or
vice versa, you must power o the system.
CAUTION: AC PSUs support both 240 V and 120 V input voltages with the exception of Titanium
PSUs, which support only 240 V. When two identical PSUs receive dierent input voltages, they
can output dierent wattages, and trigger a mismatch.
CAUTION: If two PSUs are used, they must be of the same type and have the same maximum
output power.
Drive indicator codes
The LEDs on the drive carrier indicates the state of each drive. Each drive carrier in your system has two LEDs: an activity LED (green) and
a status LED (bicolor, green/amber). The activity LED ashes whenever the drive is accessed.
Figure 92. Drive indicators on the drive and the mid drive tray backplane
1Drive activity LED indicator 2 Drive status LED indicator
3 Drive Capacity Label
NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not turn on.
128 System diagnostics and indicator codes
Table 37. Drive indicator codes
Drive status indicator code Condition
Flashes green twice per second Identifying drive or preparing for removal.
O Drive ready for removal.
NOTE: The drive status indicator remains o until all drives are
initialized after the system is turned on. Drives are not ready
for removal during this time.
Flashes green, amber, and then turns o Predicted drive failure.
Flashes amber four times per second Drive failed.
Flashes green slowly Drive rebuilding.
Solid green Drive online.
Flashes green for three seconds, amber for three seconds, and
then turns o after six seconds
Rebuild stopped.
Using system diagnostics
If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of
running system diagnostics is to test your system hardware without using additional equipment or risking data loss. If you are unable to x
the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.
Dell Embedded System Diagnostics
NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics.
The Embedded System Diagnostics provides a set of options for particular device groups or devices allowing you to:
• Run tests automatically or in an interactive mode
• Repeat tests
• Display or save test results
• Run thorough tests to introduce additional test options to provide extra information about the failed device(s)
• View status messages that inform you if tests are completed successfully
• View error messages that inform you of problems encountered during testing
Running the Embedded System Diagnostics from Boot Manager
Run the Embedded System Diagnostics (ePSA) if your system does not boot.
1 When the system is booting, press F11.
2 Use the up arrow and down arrow keys to select System Utilities > Launch Diagnostics.
3 Alternatively, when the system is booting, press F10, select Hardware Diagnostics > Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts
executing the tests on all the detected devices.
System diagnostics and indicator codes 129
Running the Embedded System Diagnostics from the Dell Lifecycle
Controller
1 As the system boots, press F10.
2 Select Hardware Diagnostics → Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The diagnostics starts
executing the tests on all the detected devices.
System diagnostic controls
Menu Description
Conguration Displays the conguration and status information of all detected devices.
Results Displays the results of all tests that are run.
System health Provides the current overview of the system performance.
Event log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event
description is recorded.
130 System diagnostics and indicator codes
Getting help
Topics:
• Recycling or End-of-Life service information
• Contacting Dell
• Accessing system information by using QRL
• Receiving automated support with SupportAssist
Recycling or End-of-Life service information
Take back and recycling services are oered for this product in certain countries. If you want to dispose of system components, visit
Dell.com/recyclingworldwide and select the relevant country.
Contacting Dell
Dell provides several online and telephone based support and service options. If you do not have an active internet connection, you can nd
contact information about your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and
some services may not be available in your area. To contact Dell for sales, technical assistance, or customer service issues:
1 Go to Dell.com/support/home
2 Select your country from the drop-down menu on the lower right corner of the page.
3 For customized support:
a Enter your system Service Tag in the Enter your Service Tag eld.
b Click Submit.
The support page that lists the various support categories is displayed.
4 For general support:
a Select your product category.
b Select your product segment.
c Select your product.
The support page that lists the various support categories is displayed.
5 For contact details of Dell Global Technical Support:
a Click Global Technical Support
b The Contact Technical Support page is displayed with details to call, chat, or e-mail the Dell Global Technical Support team.
Accessing system information by using QRL
You can use the Quick Resource Locator (QRL) located on the information tag in the front of the T340, to access the information about
the Dell EMC PowerEdge T340.
Prerequisites
Ensure that your smartphone or tablet has the QR code scanner installed.
The QRL includes the following information about your system:
• How-to videos
• Reference materials, including the Installtion and Service Manual, and mechanical overview
9
Getting help 131
• Your system service tag to quickly access your specic hardware conguration and warranty information
• A direct link to Dell to contact technical assistance and sales teams
Steps
1 Go to Dell.com/qrl and navigate to your specic product or
2 Use your smartphone or tablet to scan the model-specic Quick Resource (QR) code on your system or in the Quick Resource
Locator section.
Quick Resource Locator for Dell EMC PowerEdge T340 system
Figure 93. Quick Resource Locator for Dell EMC PowerEdge T340 system
Receiving automated support with SupportAssist
Dell EMC SupportAssist is an optional Dell EMC Services oering that automates technical support for your Dell EMC server, storage, and
networking devices. By installing and setting up a SupportAssist application in your IT environment, you can receive the following benets:
•Automated issue detection — SupportAssist monitors your Dell EMC devices and automatically detects hardware issues, both
proactively and predictively.
•Automated case creation — When an issue is detected, SupportAssist automatically opens a support case with Dell EMC Technical
Support.
•Automated diagnostic collection — SupportAssist automatically collects system state information from your devices and uploads it
securely to Dell EMC. This information is used by Dell EMC Technical Support to troubleshoot the issue.
•Proactive contact — A Dell EMC Technical Support agent contacts you about the support case and helps you resolve the issue.
The available benets vary depending on the Dell EMC Service entitlement purchased for your device. For more information about
SupportAssist, go to Dell.com/supportassist.
132 Getting help
Documentation resources
This section provides information about the documentation resources for your system.
To view the document that is listed in the documentation resources table:
• From the Dell EMC support site:
a Click the documentation link that is provided in the Location column in the table.
b Click the required product or product version.
NOTE: To locate the product name and model, see the front of your system.
c On the Product Support page, click Manuals & documents.
• Using search engines:
– Type the name and version of the document in the search box.
Table 38. Additional documentation resources for your system
Task Document Location
Setting up your system For more information about installing and securing
the system into a rack, see the Rail Installation
Guide included with your rack solution.
For information about setting up your system, see
the Getting Started Guide document that is
shipped with your system.
Dell.com/poweredgemanuals
Conguring your system For information about the iDRAC features,
conguring and logging in to iDRAC, and managing
your system remotely, see the Integrated Dell
Remote Access Controller User's Guide.
For information about understanding Remote
Access Controller Admin (RACADM)
subcommands and supported RACADM interfaces,
see the RACADM CLI Guide for iDRAC.
For information about Redsh and its protocol,
supported schema, and Redsh Eventing
implemented in iDRAC, see the Redsh API Guide.
For information about iDRAC property database
group and object descriptions, see the Attribute
Registry Guide.
Dell.com/poweredgemanuals
For information about earlier versions of the iDRAC
documents.
To identify the version of iDRAC available on your
system, on the iDRAC web interface, click ? >
About.
Dell.com/idracmanuals
For information about installing the operating
system, see the operating system documentation.
Dell.com/operatingsystemmanuals
10
Documentation resources 133
Task Document Location
For information about updating drivers and
rmware, see the Methods to download rmware
and drivers section in this document.
Dell.com/support/drivers
Managing your system For information about systems management
software oered by Dell, see the Dell OpenManage
Systems Management Overview Guide.
Dell.com/poweredgemanuals
For information about setting up, using, and
troubleshooting OpenManage, see the Dell
OpenManage Server Administrator User’s Guide.
Dell.com/openmanagemanuals > OpenManage
Server Administrator
For information about installing, using, and
troubleshooting Dell OpenManage Essentials, see
the Dell OpenManage Essentials User’s Guide.
Dell.com/openmanagemanuals > OpenManage
Essentials
For information about installing and using Dell
SupportAssist, see the Dell EMC SupportAssist
Enterprise User’s Guide.
Dell.com/serviceabilitytools
For information about partner programs enterprise
systems management, see the OpenManage
Connections Enterprise Systems Management
documents.
Dell.com/openmanagemanuals
Working with the Dell
PowerEdge RAID controllers
For information about understanding the features
of the Dell PowerEdge RAID controllers (PERC),
Software RAID controllers, or BOSS card and
deploying the cards, see the Storage controller
documentation.
Dell.com/storagecontrollermanuals
Understanding event and error
messages
For information about the event and error
messages generated by the system rmware and
agents that monitor system components, see the
Error Code Lookup.
Dell.com/qrl
Troubleshooting your system For information about identifying and
troubleshooting the PowerEdge server issues, see
the Server Troubleshooting Guide.
Dell.com/poweredgemanuals
134 Documentation resources