Legrand 0 331 80 User Manual
Displayed below is the user manual for 0 331 80 by Legrand which is a product in the Keystone Modules category. This manual has pages.
Related Manuals
87045 LIMOGES Cedex
Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88
Cat. no(s).: 0 331 80
Technical data sheet: F01421EN/02 Updated on : 01/07/2020 Created on: 20/09/2011
1/4
Keystone RJ45 socket cat.5e
UTP
1. GENERAL CHARACTERISTICS
Category 5 RJ45 socket.
Enables high speed data transmission (Gigabit Ethernet).
2. PRESENTATION
Colour code and
Contact number
Category colour code: Cat. 5 grey
Identification
number
UTP : SK01
12
3. TECHNICAL CHARACTERISTICS
3.1 Material characteristics
Contacts: gold/nickel, thickness of gold > 0.8 µm min.
Metal parts: bronze, nickel, platinum, gold
PBT polycarbonate
3.2 Electrical characteristics
Breakdown voltage ≥ 1000 V.
Contact resistance ≤ 20 mΩ.
Insulation resistance ≥ 500 MΩ at 100 V DC.
Compatible remote powering “PoE“ up to 100w. (IEEE 802.3af, IEEE 802.3at,
IEEE 802.3bt)
3.3 Mechanical characteristics
Max. number of connections and disconnections: 5 without refreshing
the cable
Endurance: 2500 movements (plug insertion/withdrawal)
IK03
3.4 Climatic characteristics
Operating temperature: - 40°C to + 70°C
Humid heat cycle 21 days
4. OVERALL DIMENSIONS
17,8
26,7
30,1
CONTENTS Page
1. General characteristics.............1
2. Presentation .....................1
3. Technical characteristics ...........1
4. Overall dimensions................1
5. Usual connection of RJ45 sockets....2
6. Standards and approvals ...........2
7. Performance...................3-4
2/4
Cat. no(s).: 0 331 80
Keystone RJ45 socket cat.5e
Technical data sheet: F01421EN/02 Updated on : 01/07/2020 Created on: 20/09/2011
This system allows the wire pairs to be spread easily before attaching
them to the connector.
Spreading the wires ensures that pairs are separated by the required
13 mm.
Spreading the pairs at 90° in relation to the cable ensures the best
performance levels.
6. STANDARDS AND APPROVALS
Conforms to standards: ISO/IEC 11801 Edition 2
CENELEC EN 50173-1 2007
ANSI/TIA 568.2-C
IEC series 60603-7
IEEE 802.3bt : PoE++
5. USUAL CONNECTION OF RJ45 SOCKETS
Accepts the following cable connectors:
RJ11 (4 contacts), RJ12 (6 contacts), RJ45 (9 contacts).
Double colour code EIA - TIA 568 A and B on terminals:
- UTP 8 contacts
Conductors supported:
- Single-core/Multicore: 0.4 to 0.65 mm, AWG 26 to 22
- Polyethylene conductor insulation: Ø 0.85 to 1.7 mm on insulation
The RJ45 connectors are equipped with a rotating locking system that
does not require special tools and enables rewiring in the event of error.
EIA 568 A
12345678 12345678
EIA 568 B
12
4
5
67
3
OK
3/4
Cat. no(s).: 0 331 80
Keystone RJ45 socket cat.5e
Technical data sheet: F01421EN/02 Updated on : 01/07/2020 Created on: 20/09/2011
7. PERFORMANCE
7.1 Performance of components (RJ 45 connectors)
Return loss
Attenuation
NEXT (Near end Crosstalk Attenuation)
0 dB
20
40
60
80
100 dB
1 MHz 10 100 125 MHz
0 dB
0.10
0.20
0.30
0.5 dB 1 MHz 10 100 125 MHz
0 dB
20
40
60
80
100 dB
1 MHz 10 100 125 MHz
1 MHz 10 100 125 MHz
0 dB
20
40
60
80
100 dB
0 dB
70
30
60
50
40
20
10
0 MHz 20 120 140 MHz
40 60 80 100
0 dB
25
20
15
10
5
0 MHz 20 120 140 MHz
40 60 80 100
7. PERFORMANCE (continued)
7.1 Performance of components (RJ 45 connectors) (continued)
FEXT (Far end Crosstalk Attenuation)
7.2 Performance of permanent link with F/UTP cable
Return loss
Attenuation
0.40
4/4
Cat. no(s).: 0 331 80
Keystone RJ45 socket cat.5e
Technical data sheet: F01421EN/02 Updated on : 01/07/2020 Created on: 20/09/2011
7. PERFORMANCE (continued)
7.2 Performance of permanent link with F/UTP cable (continued)
ELFEXT (Equal Level Far End Crosstalk Attenuation)
7. PERFORMANCE (continued)
7.2 Performance of permanent link with F/UTP cable (continued)
NEXT (Near end Crosstalk Attenuation)
PS NEXT (Power Sum NEXT)
ACR (Attenuation to Crosstalk Ratio)
0 MHz 20 120 140 MHz
40 60 80 100
0 dB
100
80
60
40
20
120
0 MHz 20 120 140 MHz
40 60 80 100
0 dB
50
40
30
20
10
0 MHz 20 120 140 MHz
40 60 80 100
0 dB
100
80
60
40
20
120
0 MHz 20 120 140 MHz
40 60 80 100
0 dB
100
80
60
40
20
120
60
70
80
90