Table of Contents
- N2225 and N2226 SAS/SATA HBAs User's Guide
- Table of Contents
- Safety
- Safety statements
- N2225 and N2226 SAS/SATA HBAs
- Appendix A: Getting Help and Technical Assistance
- Appendix B: Notices
- B.1 Trademarks
- B.2 Important notes
- B.3 Recycling information
- B.4 Telecommunication regulatory statement
- B.5 Electronic emission notices
- B.5.1 Federal Communications Commission (FCC) statement
- B.5.2 Industry Canada Class A emission compliance statement
- B.5.3 Australia and New Zealand Class A statement
- B.5.4 European Union EMC Directive conformance statement
- B.5.5 Germany Class A statement
- B.5.6 Japan VCCI Class A statement
- B.5.7 Korea Communications Commission (KCC) statement
- B.5.8 Russia Electromagnetic Interference (EMI) Class A statement
- B.5.9 People's Republic of China Class A electronic emission statement
- B.5.10 Taiwan Class A compliance statement
Lenovo N2226 User Manual
Displayed below is the user manual for N2226 by Lenovo which is a product in the Interface Cards/Adapters category. This manual has pages.
Related Manuals
N2225 and N2226 SAS/SATA HBAs
User’s Guide
Part Number: 00FH247
Second Edition (October 2015)
© Copyright Lenovo 2014, 2015. All rights reserved.
LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant a General Services Administration
“GSA” contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925.
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
- 1 -
Table of Contents
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Table of Contents
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
N2225 and N2226 SAS/SATA HBAs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2 HBA Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.1 N2225 HBA Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2 N2226 HBA Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 Functional Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.1 PCIe Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2 SAS Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Operating System Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 HBA Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1 Flash. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2 LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.3 Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.4 Physical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.5 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.6 Thermal and Atmospheric Limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6 HBAs Certifications and Safety Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7 Hardware Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
8 Replaceable HBA Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Appendix A: Getting Help and Technical Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
A.1 Before You Call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
A.2 Using the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
A.3 Getting Help and Information from the World Wide Web . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
A.4 Software service and support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
A.5 Hardware service and support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
A.6 Taiwan product service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Appendix B: Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
B.1 Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
B.2 Important notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
B.3 Recycling information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
B.4 Telecommunication regulatory statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
B.5 Electronic emission notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
B.5.1 Federal Communications Commission (FCC) statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
B.5.2 Industry Canada Class A emission compliance statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
B.5.3 Australia and New Zealand Class A statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
B.5.4 European Union EMC Directive conformance statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
B.5.5 Germany Class A statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
B.5.6 Japan VCCI Class A statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
B.5.7 Korea Communications Commission (KCC) statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
B.5.8 Russia Electromagnetic Interference (EMI) Class A statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
B.5.9 People's Republic of China Class A electronic emission statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
B.5.10 Taiwan Class A compliance statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
- 2 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Safety
Safety
- 3 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Safety
- 4 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Safety statements
Safety statements
- 5 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Safety statements
- 6 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Safety statements
- 7 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Safety statements
Statement 28:
CAUTION:
The battery is a lithium ion battery. To avoid possible explosion, do not burn the
battery. Exchange it only with the approved part. Recycle or discard the battery
as instructed by local regulations.
- 8 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
N2225 and N2226 SAS/SATA HBAs
Overview
N2225 and N2226 SAS/SATA HBAs
1Overview
The N2225 and N2226 SAS/SATA HBAs are Serial Attached SCSI (SAS) host bus adapters (HBAs) that provide
high-performance external storage connectivity for servers and workstations. The N2225 HBA provides eight lanes of
12Gb/s SAS connectivity and is matched with eight lanes of PCI Express® (PCIe®) 3.0 8Gb/s performance. The N2226
HBA provides sixteen lanes of 12Gb/s SAS connectivity and is matched with eight lanes of PCIe 3.0 8Gb/s
performance.
These HBAs are based on the Fusion-MPT™-architected LSI SAS 3008 controller that integrates the latest
enhancements in PCIe 3.0 technology and 12Gb/s SAS technology. The HBAs have onboard Flash memory for the
firmware.
2HBA Features
The following sections list the features for these HBAs.
2.1 N2225 HBA Features
Implements one LSI® SAS 3008 eight-port 12Gb/s SAS to PCIe 3.0 controller
Supports eight-lane, full-duplex PCIe 3.0 performance
Supports eight external 12Gb/s SATA+SAS ports
Supports SATA link rates of 3Gb/s and 6Gb/s
Supports SAS link rates of 3Gb/s, 6Gb/s, and 12Gb/s
Provides two x4 external mini-SAS HD connectors (SFF-8644)
Supports passive copper cables
Supports up to 1024 SATA or SAS end devices
Offered with a full-height bracket and a low-profile vented bracket
Provides one heartbeat LED
2.2 N2226 HBA Features
Implements two LSI SAS 3008 eight-port 12Gb/s SAS to PCIe 3.0 controllers
Supports eight-lane, full-duplex PCIe 3.0 performance
Supports sixteen external 12Gb/s SATA+SAS ports
Supports SATA link rates of 3Gb/s and 6Gb/s
Supports SAS link rates of 3Gb/s, 6Gb/s, and 12Gb/s
Provides four x4 external mini-SAS HD connectors (SFF-8644)
Supports passive copper cables
Supports up to 1024 SATA or SAS end devices
Offered with a full-height bracket
Provides two heartbeat LEDs
- 9 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
N2225 and N2226 SAS/SATA HBAs
Functional Descriptions
3 Functional Descriptions
3.1 PCIe Interface
PCIe is a high-speed standard local bus for point-to-point interfacing of I/O components to the processor and the
memory subsystems in high-end computers and servers. The N2225 HBA uses one LSI SAS 3008 controller chip and
one PCIe switch to provide high-bandwidth interconnection ability. The N2226 HBA uses two LSI SAS 3008 controller
chips and one PCIe switch to provide high-bandwidth interconnection ability.
Both the HBAs supports eight-lane PCIe performance up to 64Gb/s single direction and up to 128Gb/s dual direction.
3.2 SAS Interface
The LSI SAS 3008 controller chip contains the SATA+SAS functionality for the HBAs. The following table shows the
LSI SAS 12Gb/s SAS performance.
4 Operating System Support
To check for the latest list of supported operating systems and to download the device drivers for those operating
systems, see http://www.ibm.com/systems/support/.
5HBA Characteristics
5.1 Flash
The N2225 HBA provides one 4-M × 16-bit Flash ROMs to store the firmware and the BIOS.
The N2226 HBA provides two 4-M × 16-bit Flash ROMs to store the firmware and the BIOS.
5.2 LED
The N2225 HBA Heartbeat LED, CR1, blinks green to indicate the HBA is capable of general activity.
The N2226 HBA Heartbeat LEDs, CR3 and CR4, blink green to indicate the HBA is capable of general activity.
Half Duplex Full Duplex
Narrow port (one lane), 1200 MB/s Narrow port (one lane), 2400 MB/s
Wide port (four lanes), 4800 MB/s Wide port (four lanes), 9600 MB/s
- 10 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
N2225 and N2226 SAS/SATA HBAs
HBA Characteristics
5.3 Connectors
PCIe Connector (EC1). The N2226 and N2225 HBAs support a x8 interface. The PCIe host interface connection is
through the edge connector, EC1, which provides connections on both the top (EC1 B) and bottom (EC1 A) of the
board. The signal definitions and pin numbers conform to the PCIe specification.
SATA+SAS Connectors
—N2225 SATA+SAS (J6)– The N2225 HBA supports SATA and SAS connectors through connectors that are
SFF-8644 mini-SAS HD, external connectors. See Figure 1 for the connector locations.
—N2226 SATA+SAS (J6, J7) – The N2226 HBA supports SATA and SAS connectors through connectors that are
SFF-8644 mini-SAS HD, external connectors. See Figure 2 for the connector locations.
Auxiliary Power Connector (J5). The N2226 HBA provides a 6-pin PCIe power connector.
5.4 Physical Characteristics
5.4.1 N2225 HBA Physical Characteristics
The N2225 SAS HBA is a 6.6-in. × 2.7-in., low-profile board. The component height on the top and bottom of the HBA is
in accordance with the PCIe specification. The following figure shows the HBA board layout.
Figure 1 N2225 SAS/SATA HBA Board Layout
EC1 – PCIe x8 board edge connector
CR1 – Heartbeat LED
J6 – SFF-8644 mini-SAS HD, external, right-angle connectors
/6,6$6
(& B
&5
3RUW
-
3RUW
- 11 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
N2225 and N2226 SAS/SATA HBAs
HBA Characteristics
5.4.2 N2226 HBA Physical Characteristics
The N2226 SAS HBA is a 6.6-in. × 4.4-in board. The component height on the top and bottom of the HBA is in
accordance with the PCIe specification. The following figure shows the HBA board layout.
Figure 2 N2226 SAS/SATA HBA Board Layout
EC1 – PCIe x8 board edge connector
CR3, CR4 – Heartbeat LEDs
J5 – Auxiliary power connector
J6, J7 – SFF-8644 mini-SAS HD, external, right-angle connectors
5.5 Electrical Characteristics
5.5.1 N2225 HBA Electrical Characteristics
The power requirements for the N2225 HBA under normal operation are as follows:
PCIe 12.0 V = 1.07 A
Power values:
—Nominal = 14.5 W
—Worst case = 22.5 W
5.5.2 N2226 HBA Electrical Characteristics
The power requirements for the N2226 HBA under normal operation are as follows:
PCIe 12.0 V = 2.35 A
PCIe 3.3 V = 0.13 A
Power values:
—Nominal = 28.6 W
—Worst case = 35.4 W
5.6 Thermal and Atmospheric Limits
The atmospheric limits for the HBAs are as follows:
Temperature range: 0 °C to 55 °C (32 °F to 131 °F) (dry bulb)
(& B
3RUW
-
3RUW
3RUW
-
3RUW
-
/6,6$6
/6,6$6
&5
&5
- 12 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
N2225 and N2226 SAS/SATA HBAs
HBAs Certifications and Safety Characteristics
Relative humidity range: 5% to 90% noncondensing
Maximum dew point temperature: 32 °C (89.6 °F)
Minimum airflow
—N2225 HBA:
200 linear feet per minute
—N2226 HBA:
220 LFPM at 35 °C inlet temperature
270 LFPM at 45 °C inlet temperature
350 LFPM at 55 °C inlet temperature
The following limits define the storage and transit environment for the HBAs:
Temperature range: –45 °C to +105 °C (–49 °F to +221 °F) (dry bulb)
Relative humidity range: 5% to 90% noncondensing
6 HBAs Certifications and Safety Characteristics
The HBAs meet or exceed the requirements of UL flammability rating 94V-0. Each bare board is marked with the
supplier’s name or trademark, type, and UL flammability rating. Because these boards are installed in a PCIe bus slot,
all voltages are less than the SELV 42.4-V limit.
The design and implementation of the HBAs minimize electromagnetic emissions, susceptibility to radio frequency
energy, and the effects of electrostatic discharge.
The HBAs meet the following integrated electromagnetic interference (EMI) compliance labels:
CE mark
CISPR Class B
C-Tick mark
Canadian Compliance Statement
FCC Class B, marked with the FCC Self-Certification logo
Japan VCCI
Korean KCC
Taiwan BSMI
The HBAs meet the following environmental directives:
RoHS
WEEE
- 13 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
N2225 and N2226 SAS/SATA HBAs
Hardware Installation Instructions
7 Hardware Installation Instructions
To install the HBAs, follow these steps:
1. Unpack the HBA and inspect if for damage. If it appears damaged, or if any of the following items are missing,
contact your place of purchase. The HBA is shipped with the following items:
A CD containing an electronic version of this User’s Guide and other related documentation.
Warranty information
ATTENTION Make a backup of your data before changing your system configuration to avoid the risk of
data loss.
- 14 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
N2225 and N2226 SAS/SATA HBAs
Hardware Installation Instructions
2. Prepare the computer. Turn off the computer, and disconnect the power cord from the rear of the power supply.
3. Remove the cover from the chassis.
4. Check the mounting bracket on the HBA (system-dependent). If required for your system, replace the
full-height mounting bracket that ships on the HBA with the low-profile bracket supplied.
5. Insert the HBA into an available PCIe slot.
a. For N2225 ONLY. Locate an empty x8 PCIe slot. Remove the blank bracket panel on the rear of the computer
that aligns with the empty PCIe slot. Save this bracket screw, if applicable. Align the HBA to a PCIe slot. Press
down gently, but firmly, to seat the HBA correctly in the slot. The following figures show how to insert the
HBA into a PCIe slot.
Figure 3 Install an N2225 HBA in a PCIe Slot
a. For N2226 ONLY. Locate an empty x8 PCIe slot. The N2226 is a high power HBA and must be installed in a
75W slot, or an external power connector cable must be installed from the N2226 to the server. Remove the
blank bracket panel on the rear of the computer that aligns with the empty PCIe slot. Save this bracket screw,
if applicable. Align the HBA to a PCIe slot. Press down gently, but firmly, to seat the HBA correctly in the slot.
The following figures show how to insert the HBA into a PCIe slot.
CAUTION Disconnect the computer from the power supply and from any networks to which you will
install the HBA, or you risk damaging the system or experiencing electrical shock.
NOTE The shape, size, and locations of the components on your HBAs and its bracket might vary from this
illustration. The HBAs require a x8 PCIe slot.
NOTE The shape, size, and locations of the components on your HBAs and its bracket might vary from this
illustration. The HBAs require a x8 PCIe slot.
B
(GJHRI+RVW%RDUG
%LW6ORWV
92QO\
3&,([SUHVV
[6ORW
%LW6ORW
92QO\
%UDFNHW
6FUHZ
3UHVV
+HUH
3UHVV
+HUH
7R'ULYH
(QFORVXUHV
0LQL6$6+'
([WHUQDO
&RQQHFWRUV
- 15 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
N2225 and N2226 SAS/SATA HBAs
Replaceable HBA Components
Figure 4 Install an N2226 HBA in a PCIe Slot
6. Secure the HBA bracket to the system’s chassis. Install the bracket screw, if applicable, or engage the system
retention mechanism to secure the HBA to the system’s chassis.
7. Replace the cover of the chassis.
8. Connect SAS cables between the HBA and the SAS enclosure that contains SATA or SAS devices. The N2225
HBA has two, SFF-8644, external x4 mini-SAS HD connectors. The N2226 HBA has four SFF-8644, external x4
mini-SAS HD connectors. Use a cable with an external mini-SAS HD connector (SFF-8644) on one end (to connect
to the HBA) and the appropriate connector to attach to the enclosure that contains SAS or SATA devices on the
other end.
9. Replace the cover and any power cords, and power up the system. Replace the chassis’s cover, reconnect any
power cords, and reconnect any network cables. Turn on the power.
The hardware installation of your SAS HBAs is complete.
8 Replaceable HBA Components
The field replaceable unit (FRU) part number for the N2225 HBA is 00AE914.
The field replaceable unit (FRU) part number for the N2226 HBA is 00AE918.
B
(GJHRI+RVW%RDUG
3&,([SUHVV[6ORW
%UDFNHW
6FUHZ
3UHVV
+HUH
3UHVV
+HUH
7R'ULYH
(QFORVXUHV
0LQL6$6+'
([WHUQDO
&RQQHFWRUV
- 16 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix A: Getting Help and Technical Assistance
Before You Call
Appendix A: Getting Help and Technical Assistance
A.1 Before You Call
- 17 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix A: Getting Help and Technical Assistance
Using the Documentation
A.2 Using the Documentation
A.3 Getting Help and Information from the World Wide Web
- 18 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix A: Getting Help and Technical Assistance
Software service and support
A.4 Software service and support
A.5 Hardware service and support
A.6 Taiwan product service
- 19 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix B: Notices
Appendix B: Notices
- 20 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix B: Notices
Trademarks
B.1 Trademarks
B.2 Important notes
- 21 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix B: Notices
Recycling information
B.3 Recycling information
B.4 Telecommunication regulatory statement
B.5 Electronic emission notices
B.5.1 Federal Communications Commission (FCC) statement
- 22 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix B: Notices
Electronic emission notices
B.5.2 Industry Canada Class A emission compliance statement
B.5.3 Australia and New Zealand Class A statement
B.5.4 European Union EMC Directive conformance statement
- 23 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix B: Notices
Electronic emission notices
B.5.5 Germany Class A statement
- 24 -
N2225 and N2226 SAS/SATA HBAs User’s Guide
October 2015
Appendix B: Notices
Electronic emission notices
B.5.6 Japan VCCI Class A statement
B.5.7 Korea Communications Commission (KCC) statement
B.5.8 Russia Electromagnetic Interference (EMI) Class A statement
B.5.9 People's Republic of China Class A electronic emission statement
B.5.10 Taiwan Class A compliance statement