Displayed below is the user manual for LTO-6 HH SAS by Overland-Tandberg which is a product in the Backup Storage Devices category. This manual has pages.
Related Manuals
1004080-000 Rev C
#1004080-000C#
1Tandberg Data Corporation
Bar Code Label Specification
2for LTO Ultrium
Cartridges
2 1004080
Copyright
Copyright 2000 – 2007 by Tandberg Data Corporation. All rights
reserved. This item and the information contained herein are the
property of Tandberg Data Corporation. No part of this document may
be reproduced, transmitted, transcribed, stored in a retrieval system, or
translated into any language or computer language in any form or by
any means, electronic, mechanical, magnetic, optical, chemical, manual,
or otherwise, without the express written permission of Tandberg Data
Corporation, 2108 55th Street, Boulder, Colorado 80301.
Disclaimer
Tandberg Data Corporation makes no representation or warranties with
respect to the contents of this document and specifically disclaims any
implied warranties of merchantability or fitness for any particular
purpose. Further, Tandberg Data Corporation reserves the right to revise
this publication without obligation to notify any person or organization
of such revision or changes.
Trademark Notices
Exabyte, the Exabyte Logo, EZ17, M2, VXA, and VXAtape are registered
trademarks; ExaBotics, MammothTape, and SmartClean are
trademarks; SupportSuite is a service mark.
Linear Tape-Open, LTO, the LTO Logo, Ultrium and the Ultrium Logo
are trademarks of HP, IBM, and Quantum in the US and other countries.
All other product names are trademarks or registered trademarks of their
respective owners.
Revision History
Tandberg Data Corporation
2108 55th Street
Boulder, Colorado USA 80301
www.tandbergdata.com/us
Revision Date Description
000 August 2000 Initial Release
B June 2004 Update address
C April 2007 Converted to Tandberg
1004080 3
Contents
“About this Specification” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
“Symbology” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
“Bar Code Characters” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
“Encodation” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
“Quiet Zone” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
“Optical Specification” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
“Label Dimensions” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
“Volume Identifier Formats” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
4 1004080
About this Specification
This document provides specifications for creating bar code labels
used on cartridges in Tandberg Data LTO Ultrium libraries. The
specifications are defined to both standardize labels and allow users
the option of purchasing or printing their own labels. This
specification contains the following information about the bar code
labels:
Symbology
Bar code characters
Encodations
Quiet zone
Optical specification
Label dimensions
Volume identifier formats
Symbology
The LTO Ultrium cartridge label uses the bar code symbology of
USS-39. A description and definition of this symbology is available
from the Automatic Identification Manufacturers (AIM)
specification Uniform Symbol Specification (USS-39) and the ANSI
MH10.8M-1993 ANSI Barcode specification.
1004080 5
Bar Code Characters
The bar code string consists of a start character, eight alphanumeric
characters, and the stop character. Quiet zones precede and follow
the start and stop characters. The first six characters may be any
combination of upper case A through Z or 0 through 9 (for example,
ABC123) to identify the cartridge volume. The last two characters are
determined by the LTO Ultrium cartridge media type (for example
“L” for LTO Ultrium and “1” for tape cartridge generation or drive
manufacturer-unique identifier).
Only upper case alpha A through Z or numeric 0 through 9
characters are allowed.
Human readable characters may be used, provided there is not a
conflict or interference with the automation code. The user specifies
the format, colors, and location of the human readable characters.
Encodation
Refer to the AIM Uniform Symbol USS-39 specification for the
description and format of the start character, identifier characters,
and stop character.
Quiet Zone
The quiet zones are the areas preceding the start and after the stop
characters. They are clear of any printing or reflective properties that
could cause spurious reflections. The quiet zones are further defined
in the AIM Uniform Symbol USS-39 specification.
6 1004080
Optical Specification
The optical specifications for the bar code labels are listed below.
Use the white calibration standard to calibrate the print contrast
of the Mcbeth PCMII. Be sure the filter select switch is on position
A for all calibration and measurements.
The reflectivity of the white background (RW) is the reflectivity
measured in the center of narrow spaces using the Mcbeth PCMII
print contrast meter. The RW must be between 70% and 85%. At
this measurement, isolated print defects and edge roughness are
avoided.
A spot is defined as an area anywhere within the white
background in which the reflectivity is less than 65%. Spots may
not be greater than 0.004 inches (0.102 mm) enclosed diameter.
There may be no more than five spots in the bar code area per
label. Spots may not be any closer to each other than 0.01 inches
(0.254 mm).
The reflectivity of the black areas (RB) may be measured anywhere
within any black area on the bar code. The print contrast signal
(PCS) is defined as (RW-RB)/RW and is measured using the
Mcbeth PCMII print contrast meter. PCS must be a minimum of
0.85. Using the PCS measurement will avoid isolated print defects
and edge roughness.
A void is an area within a black area where the PCS is less than
0.85. No voids may be greater than 0.004 inches (0.102 mm)
enclosed diameter. There may be no more than five voids in the
bar code area per label. Voids may not be any closer to each other
than 0.01 inches (0.254 mm).
Note: For additional optical requirements and measurement
techniques, refer to the AIM Uniform Symbol USS-39
specification.
1004080 7
Label Dimensions
The following figure shows the bar code label dimensions.
Note: Dimensions are given in inches with millimeters in
parentheses.
The following table lists the bar code label dimension specifications.
f
0
0
3
2
1
L1
0
Alphanumeric
characters
Bar code
3.110 +0/-.031
[79.00 +0/-.80]
2x .170 Minimum (Quiet zone)
[4.32]
2.917 0.015
[74.09 0.038]
0.437 Minimum
[11.10 Minimum]
.669 +0/-.031
[17.00 +0/-.80]
8 1004080
Note: The LTO Ultrium label dimensions are derived using the
AIM USS-39 specification.
Specification Dimension
Symbol height 0.44 inches (11.1 mm) minimum as measured to the
inside of the edge roughnessa
Wide to narrow ratio 1:2.75
Narrow element width 0.017 inches + 0.001/–0.003 inches (0.432 mm +0.03/
–0.076 mm)
Nominal width of wide
spaces and bars
0.047 inches (1.188 mm)
Inter character gap 0.017 inches +0.001/–0.003 inches (0.432 mm +0.03/
–0.076 mm)
Bar code element
width maximum
Measured to the outside of the edge roughnessa.
Space width is then the distance between bar maxima.
Quiet zone at the
beginning and end of
printed bar code string
10× narrow width = 0.17 inches (4.32 mm)
Total bar code string
length, including quiet
zones
Nominal 2.917 inches (74.088 mm)
Bar code string
direction
May be printed in either direction on the label but must
begin/end with a valid start/stop character (✱)
Edge roughnessa0.0015 inches (0.038 mm) maximum
Tolerances 0.XXX± 0.005 inches, 0.XX±.0.03 inches)
(0.XXX± 0.127 mm, 0.XX± 0.762 mm)
Variation between all
wide bars, white and
black
Less than ± 0.0015 inches (0.0381 mm)
Variation between all
narrow bars, white
and black
Less than ± 0.0015 inches (0.0381 mm)
1004080 9
Print side Print the bar code string on the label so it is on the side
of the label towards the hub
Label stock
dimensions
3.110 x 0.669 inches (79 × 17 mm)b
Minimum length for
quiet zones, start-stop
and data characters
Nominal 2.917 inches (74.088 mm)
Minimum width No less than 0.059 inches (1.5 mm) narrower than the
cartridge label recess width
Corner cut 0.059 inches (1.5 mm radius)
aThe edge roughness is defined as the transition encountered as a horizontal line is moved
vertically from all black to all white. The bar code edge is defined as the edge of all printed area
attached to the bar.
bMust fit within the label recess on the face of the cartridge without curling up on the sides or ends.
Specification Dimension (Continued)
10 1004080
Volume Identifier Formats
The volume identifier only uses ASCII characters A through Z (41h-
5Ah), 0 through 9 (30h-39h), and the combinations of “CLN” and
“DG{space}” as described below.
The prefix “CLNvnnL1”is reserved for cleaning cartridges. The “v”
field is an alphanumeric field to identify a drive-unique cleaning
cartridge. The “nn” alphanumeric field is used to track individual
cleaning cartridge activity (for example, usage and life). When the
drive requires cleaning, it will request loading of the unique type
cleaner cartridge.
Diagnostic/Service cartridges use the prefix “DG{space}vnnL1”.
The “v” field is an alphanumeric field to identify a drive-unique
diagnostic cartridge, if required. The “nn” alphanumeric field
identifies a specific diagnostic cartridge volume.
The volume identifier field consists of six left-justified
alphanumeric characters as specified in SCSI-3 Medium Changer
Commands (SMC) ANSI NCITS 314-199X.
The media identifier characters “Lg” are controlled characters. The
“L” designates the LTO Ultrium type of cartridge. The next
character “g” (alphanumeric) designates the generation of the
LTO Ultrium cartridge.
End of document