Peerless PSTK-028-W User Manual
Displayed below is the user manual for PSTK-028-W by Peerless which is a product in the Projector Mounts category. This manual has pages.
Related Manuals
Models: PSTA-028, PSTA-028-W, PSTK-028, PSTK-028-W
Installation and Assembly:
Universal Projector Wall Arm
ISSUED: 03-23-09 SHEET #:055-9260-8 04-25-13
2300 White Oak Circle • Aurora, Il 60502 • (800) 865-2112 • Fax: (800) 359-6500 • www.peerless-av.com
Max UL Load Capacity: 50 lb (22.7 kg)
Visit the Peerless Web Site at www.peerless-av.com ISSUED: 03-23-09 SHEET #:055-9260-9 05-23-14
2 of 9
Note: Read entire instruction sheet before you start installation and assembly.
Tools Needed for Assembly
• stud nder ("edge to edge" stud nder recommended)
• level
• drill
• 5/32" drill bit for wood studs
• 5/16" dill bit for solid concrete and cinder block
• phillips screwdriver
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings
contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US
customers please call Peerless customer care at 1-800-865-2112, for all international customers, please contact
your local distributor.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building
construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Never exceed the Maximum Load Capacity. See page one.
• If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of
an "edge to edge" stud nder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws rmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding
power.
• This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal
injury.
• This product was designed to be installed on the following wall construction only;
WALL CONSTRUCTION HARDWARE REQUIRED
•Wood Stud Included
• Wood Beam Included
• Solid Concrete Included
• Cinder Block Included
WARNING
Table of Contents
Parts List.................................................................................................................................................................................3
Installation to Wood Stud .................................................................................................................................................... 4,6
Installation to Solid Concrete/Cinder Block ....................................................................................................................... 5,7
Assembly of Adjustment Tube ...............................................................................................................................................8
Installing Projector Mount ......................................................................................................................................................8
Routing Cables .......................................................................................................................................................................9
Visit the Peerless Web Site at www.peerless-av.com ISSUED: 03-23-09 SHEET #:055-9260-9 05-23-14
3 of 9
AB
Before you start check the parts list to ensure all of the parts shown are included.
IMPORTANT: Read instruction sheet before you start installation and assembly.
NOTE: Some parts may appear slightly different than illustrated.
EF
D
G
C
H
J
I
KLM
Parts List PSTA-028
Part #
PSTA-028-W
Part #
PSTK-028
Part #
PSTK-028-W
Description Qty Part #
Awall arm 1 055-1909 055-2909 055-1909 055-2909
Bcarriage 1 056-1332 056-2332 056-1332 056-2332
C4 mm allen wrench 1 560-9646 560-9646 560-9646 560-9646
DM5 x 10 mm serrated socket pin screw 4 520-1063 520-2063 520-1063 520-2063
E#14- x 2.5 wood screw 4 5S1-015-C03 5S1-015-C04 5S1-015-C03 5S1-015-C04
Ftube cap 1590-1274 590-1274 590-1274 590-1274
Gconcrete anchor 4 590-0320 590-0320 590-0320 590-0320
H1/4"-20 socket pin screw 2 520-1054 520-2069 520-1054 520-2069
I1/4"-20 at washer 2540-1078 540-2078 540-1078 540-2078
Jprojector mount 1PRGS-UNV PRGS-UNV-W PRGS-UNV PRGS-UNV-W
Kwall plate 1 — — 055-1923 055-2923
L5/16 -18 x 1/2 carriage bolt 4 — — 520-9207 520-2047
M5/16 - 18 serrated anged lock nut 4 — — 530-1016 530-2016
Visit the Peerless Web Site at www.peerless-av.com ISSUED: 03-23-09 SHEET #:055-9260-9 05-23-14
4 of 9
Note: For PSTK-028 models, refer to page 6.
Use a stud nder to locate the edges of the stud. Use of an edge-to-edge stud nder is highly recommended.
Based on its edges, draw a vertical line down the stud’s center. Place wall arm (A) on wall as a template. Mark the
center of the four mounting holes. Drill four 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Secure wall arm (A) to
wood stud using four #14 x 2-1/2" wood screws (E) as shown.
Optional: Rotate wall arm 180° to position the arm closer to the ceiling.
Skip to Step 2.
1
E
A
Installation to Wood Stud Walls for PSTA-028, PSTA-028-W Models
• When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the
wood studs are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8".
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud nder
is highly recommended.
WARNING
Visit the Peerless Web Site at www.peerless-av.com ISSUED: 03-23-09 SHEET #:055-9260-9 05-23-14
5 of 9
Note: For PSTK-028 models, refer to page 6.
Drill four 5/16" (8 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Insert anchors (G) in
holes ush with wall as shown. Attach wall arm
(A) using four #14 x 2 -1/2" wood screws (E) as
shown in Illustration A and 1, 2, and 3. Tighten
all fasteners. Optional: Rotate wall arm 180° to
position the arm closer to the ceiling.
Skip to Step 2.
1
E
G
Illustration A
A
Installation to Solid Concrete or Cinder Block Wall
for PSTA-028, PSTA-028-W Models
• Tighten wood screws rmly, but do not overtighten.
Overtightening can damage the screws, greatly
reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
1
3
G
Drill holes and insert anchors (G).
Place plate (A) over anchors (G) and secure with screws (E).
Tighten all fasteners.
2
G
A
E
concrete
surface
SOLID CONCRETE CINDER
BLOCK
• When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum
compressive strength of 2000 psi.
• When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90 specications
and have a minimum nominal width of 8".
• Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the
side of the block. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Never attach concrete expansion anchors to concrete or cinder block covered with plaster, drywall or other nishing
material.
WARNING
Visit the Peerless Web Site at www.peerless-av.com ISSUED: 03-23-09 SHEET #:055-9260-9 05-23-14
6 of 9
K
L
M
E
Installation to Wood Stud Wall for PSTK-028, PSTK-028-W
K
A
Secure wall arm (A) to wall plate (K) using four carriage bolts (L) and lock nuts (M).
Installation to Wall Plate For PSTK-028, PSTK-028-W Models
Use a stud nder to locate the edges of the stud. Use of an edge-to-edge stud nder is highly recommended.
Based on its edges, draw a vertical line down the stud’s center. Place wall plate (K) on wall as a template. Mark
the center of the four mounting holes. Drill four 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Secure wall plate
(K) to wood stud using four #14 x 2-1/2" wood screws (E) as shown.
Optional: Rotate wall arm 180° to position the arm closer to the ceiling.
1-1
1
• When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the
wood studs are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8".
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that wall plate is rmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud nder
is highly recommended.
WARNING
Visit the Peerless Web Site at www.peerless-av.com ISSUED: 03-23-09 SHEET #:055-9260-9 05-23-14
7 of 9
E
G
Illustration A
K
Installation to Solid Concrete or Cinder Block Wall
for PSTK-028, PSTK-028-W
Drill four 5/16" (8 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Insert anchors (G) in
holes ush with wall as shown. Attach wall plate
(K) using four #14 x 2 -1/2" wood screws (E) as
shown in Illustration A and 1, 2, and 3. Tighten all
fasteners.
Optional: Rotate wall arm 180° to position the arm
closer to the ceiling.
• Tighten wood screws rmly, but do not overtighten.
Overtightening can damage the screws, greatly
reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
1
3
G
Drill holes and insert anchors (G).
Place plate (K) over anchors (G) and secure with screws (E).
Tighten all fasteners.
2
G
K
E
concrete
surface
1
SOLID CONCRETE
CINDER
BLOCK
• When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum
compressive strength of 2000 psi.
• When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90 specications
and have a minimum nominal width of 8".
• Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the
side of the block. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Never attach concrete expansion anchors to concrete or cinder block covered with plaster, drywall or other nishing
material.
WARNING
Visit the Peerless Web Site at www.peerless-av.com ISSUED: 03-23-09 SHEET #:055-9260-9 05-23-14
8 of 9
Slide carriage (B) over wall arm (A) and adjust to the desired projector throw distance as shown. Lock carriage
(B) into place using four M5 x 10 mm screws (D).
B
A
Assembly of Adjustment Tube
Installing PRGS projector mount to wall arm assembly: Attach PRGS projector mount (J) to carriage (B) using
two 1/4-20 phillips screws (H) and two at washers (I) as shown below.
D
Installing PRGS Projector Mount
B
2
3
H
I
J
Visit the Peerless Web Site at www.peerless-av.com ISSUED: 03-23-09 SHEET #:055-9260-9 05-23-14
9 of 9
Routing Cables
Routing Cables through PRGS projector mount and wall arm assembly: Guide projector cables into
openings in projector mount and wall arm assembly as shown below. Insert Tube Cap (F) into end of wall arm (A).
Note: Cables must be removed from projector before routing through wall arm.
Note: Follow projector mount (PRGS) instructions to install projector.
F
A
PROJECTOR CABLES
© 2013, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Peerless Industries, Inc.
2300 White Oak Circle
Aurora, Il 60502
www.peerless-av.com
4