Philips AVENT SCF292/01 User Manual
Displayed below is the user manual for SCF292/01 by Philips AVENT which is a product in the Breast Pumps category. This manual has pages.
Related Manuals
1
Warnings and Cautions
TM
Handheld Electronic Breast Pump
ISIS UNO
Guide to Your Pump
When using electrical products,especially when children are present, basic safety
precautions should always be followed,including the following.
READ ALL INSTRUCTIONS BEFORE USING YOUR ISIS iQ UNO™ BREAST PUMP.
WARNING – To reduce the risk of fire, electrocution, or other personal injury:
• ISIS iQ UNO is intended for repeated use by a single user only.
• Always unplug from the electrical wall outlet immediately after use.
• Do not use while bathing.
• Do not place or store the product where it can fall or be pulled into a tub or sink.
• Do not place or drop the control handle, battery pack or wall plug cord into water or other liquids.
• Do not reach for a product that has fallen into water. Unplug from the wall outlet immediately.
• Close supervision is necessary when this product is used near children or persons with disabilities.
• Do not allow children or pets to play with the control handle,battery pack, wall plug cord or
accessories as these parts may pose a choking or strangulation danger.
• Before each use inspect the product, including wall plug cord, for signs of damage. Never operate
this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or
damaged, or has been submerged in water.
• Only use attachments recommended by AVENT.
• Do not use outdoors or where aerosol spray products are being used, or where oxygen is
being administered.
• Equipment not suitable for use in the presence of flammable anaesthetic mixture with
air, or with oxygen or nitrous oxide.
• Only use the wall plug cord and battery pack supplied with the product.
• There are no user serviceable parts inside the ISIS iQ UNO. Do not attempt to open,
service or repair the ISIS iQ UNO yourself.
• Keep cords away from heated surfaces.
• This product is a personal care item and should not be shared between mothers.
• Do not attempt to remove the pump body from your breast while under vacuum. Turn the unit
off and break the seal between your breast and the pump funnel with your finger,then remove
the pump from your breast.
• Do not operate unless control handle is connected to a pump body.
• Never use while pregnant, as pumping can induce labor.
• Never use when sleepy or drowsy.
CAUTION – To reduce the risks of injury, device malfunction or failure:
• The product should not be left unattended when plugged into an electrical outlet.
• Never drop or insert any foreign object into any opening.
• Make sure the voltage of the wall plug cord is compatible with the power source.
• Plug the end of the wall plug cord into the control handle first, then securely attach the
wall plug into the outlet.
• Although compliant with applicable EMC directives, this equipment may still be susceptible to
excessive emissions and/or may interfere with more sensitive material.
• Wash and sanitize the appropriate pump parts before each use.
• Do not continue pumping for more than five minutes at a time if no result is achieved.
• Do not use antibacterial cleaners or detergents when cleaning breast pump parts.
• Never put the control handle or battery pack, or cord in water or sterilizer, as you can cause
permanent damage to the pump.
• If the pressure generated is uncomfortable or causing pain, turn the unit off, break the seal
between the breast and the pump body with your finger and remove the pump from your breast.
2
ISIS iQ UNO Pump Parts Guide
Pump Parts
All you need to assemble and use ISIS iQ is shown here. If any of the parts
are missing, or if you have any questions, please call customer support at
1.800.54.AVENT or visit www.aventamerica.com
3
ISIS iQ UNO Pump Parts Guide – Detailed
Battery Pack
Power cable
On/Off switch
NEVER SANITIZE OR IMMERSE IN WATER
NEVER SANITIZE OR IMMERSE IN WATER
Control Handle
Only the following batteries are compatible with the ISIS
iQ UNO Battery Pack: Duracell Ultra M3, Duracell Plus,
Energiser Ultra Plus, Duracell Accu (NiMH), Ansmann
(NiMH) For Duracell Acc (NiMH) & Ansmann (NiMH) use /
charge in accordance with manufacturers guidelines.
Dispose of batteries as per manufacturers instructions.
One-touch
Memory Control
Light
Power socket
Control handle
Control handle
Silicone diaphragm
2 White valves
Pump body
Reusable bases (125 ml/
4oz and 260 ml/9 oz)
Stand (same as )
Let-down Massage
Cushion™
Funnel cover (same as )
Battery pack
Wall plug cord
1 Dome cap
1 Newborn nipple (0m+)
1 Screw ring
1 Travel cover
2 Sealing discs
f
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
h
j
i
d
e
f
g
h
a
c
b
Bottle Parts
k
l
n
o
m
4
Please take a few minutes to read through
this entire instruction leaflet before using
your ISIS iQ UNO for the first time.
PLEASE SAVE THESE INSTRUCTIONS.
Congratulations!
Congratulations! Soon you will discover what makes this ISIS iQ Breast Pump so
uniquely yours. ISIS iQ is designed with an electronic memory that learns and
continues your gentle pumping rhythm. It gives you complete control over your
comfort, which means that pumping with ISIS iQ always feels natural and exactly
right for you.
Intuitive and intelligent... It’s your iQ.
Let-down Massage Cushion™has petals that
flex in and out to gently massage the area
around your breast.This is intended to help
stimulate a fast, natural milk flow.
One-touch Memory Control gives you instant
control over comfort, right at your fingertips.
You stop, start or adjust the speed and suction
level without removing your hand from the pump.
Electronic Memory learns from you.
Just begin a comfortable pumping rhythm,
press a button and ISIS iQ automates it.
Pump, Store, Feed Convenience from
the AVENT Natural Feeding System. AVENT
products work together, so you never have
to transfer milk between containers.
Ultra Comfortable, Quiet and Effective
making it easier for you to continue giving
your baby the benefits of breast milk.
What’s Inside:
Pumping with ISIS iQ UNO
(Battery or Electric)
Warnings and Cautions 1
ISIS iQ UNO Pump Parts Guide 2-3
Disassembling ISIS iQ UNO 5
Cleaning and Sanitizing ISIS iQ UNO 6
Preparing to Pump 7-8
Assembling the Pump Body
of the ISIS iQ UNO 9-10
Connecting the Electronics
of ISIS iQ UNO 11-12
Pumping with ISIS iQ UNO 13-15
Manual Pumping with ISIS
ISIS Manual Pump Parts Guide 16
Cleaning the ISIS Manual Pump 16
Assembling the ISIS Manual Pump 17-18
Using the ISIS Manual Pump 19
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Keeping Parts Clean and
Compact for Travel 20
Storing Your Expressed Breast Milk 21
Technical Specifications 22
Troubleshooting Guide 23-24
HELPFUL TIP!
The AVENT Electronic, Electric and Microwave Steam
Sterilizers are designed to hold the washable components
of the ISIS iQ UNO and the entire ISIS Manual Pump.
6
Cleaning and Sanitizing ISIS iQ UNO
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
2
1
5
Disassembling ISIS iQ UNO
Before you use your breast pump for the first time and every time before use,
you must disassemble, wash and sanitize all the breast pump parts that come
into contact with your breast milk.
Disassembly
Turn the pump off, unplug from electrical wall
outlet and disconnect the wall plug cord or
battery pack from the control handle. Pull the
control handle directly upwards away from the
diaphragm then unhook it from the stem by
moving it towards the funnel.
Remove the silicone diaphragm by
pulling it away from the pump body.
3
4Remove the Let-down Massage Cushion™
by gently pulling it away from the funnel
on the pump body.
Remove the white valve from
the pump body.
Clean Before Every Use (including first use):
Silicone diaphragm (b)
White valve (c)
Pump body (d)
Reusable base (e)
Let-down Massage Cushion™ (g)
Funnel cover/White stand (h/f)
Cleaning Instructions:
These pump parts should be sanitized after every use.
Disassemble the pump before cleaning. Wash in warm soapy
water and rinse, or wash on the top rack of the dishwasher.
Sanitize in a steam sterilizer (Electronic, Electric or Microwave)
or by boiling in water for 10 minutes.
CAUTION: DO NOT USE ANTIBACTERIAL CLEANERS OR DETERGENTS
WHEN CLEANING BREAST PUMP PARTS.
Clean with a Damp Cloth when Necessary:
Control handle (a)
Battery pack (i)
Wall plug cord ( j)
These components DO NOT
come into contact with your breast milk.
You can wipe the control handle clean, using a soft cloth.
CAUTION: NEVER PUT THE CONTROL HANDLE, BATTERY PACK OR WALL PLUG CORD
IN WATER OR A STERILIZER, AS YOU CAN CAUSE PERMANENT DAMAGE TO THE PUMP
a
cdegh
ij
b
f
8
Preparing to Pump
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
7
Preparing to Pump
You can use ISIS iQ UNO as a:
Handheld Electric Pump
Manual Pump
(to use the ISIS Manual Pump, see pages 15-17)
When using the pump for the first time, your ISIS iQ will have retained factory settings
stored in the memory as a result of quality control testing. If the blue One-Touch
Memory Control is pressed prior to squeezing the control handle upon first use the
pump will operate at these settings, which may or may not be comfortable for you.
We recommend that prior to engaging the automatic mode, you establish
a comfortable rhythm manually, then press the blue One-Touch Memory Control
to continue your preferred rhythm.
If you find that you are not expressing a lot of milk the first few times you pump,
don’t be discouraged. Learning to express milk, like breastfeeding, takes practice.
Here are some tips that might make pumping easier:
1. Choose a time when you’re not rushed
and won’t be interrupted.
2. Look at a photograph of your baby to help
encourage let-down.
3. Place a warm cloth on your breasts for a few minutes
before you start pumping.This encourages milk
flow and can soothe painful breasts.
4. Warmth and relaxation can encourage milk
flow. Try expressing after a bath or shower.
5. Try expressing from one breast while your baby
is feeding on the other, or continue expressing
just after a feed.
6. Reposition the pump on your breasts from time
to time.This can stimulate your milk ducts.
How quickly will the milk flow begin?
When pumping with the ISIS iQ UNO, your milk should begin to flow after a
few compressions. If your milk does not begin to flow immediately, relax and
continue pumping.
CAUTION: DO NOT CONTINUE PUMPING FOR MORE THAN 5 MINUTES AT A TIME
IF NO RESULT IS ACHIEVED.
Stop, and try expressing milk at another time of day. If the process becomes
painful, stop and consult your lactation consultant or breastfeeding advisor.
How much milk can you expect?
On average you will need to pump for 10 minutes to express 60-120 mls
or 2-4 ounces of milk. However, this is just a guide and varies from woman
to woman. If you find that you regularly express more than 4 ounces of milk
per session, attach a 9 oz/260 ml AVENT reusable base to the pump body.
Handheld Battery-Powered Pump
Assembling the Pump Body of the ISIS iQ UNO
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
2
1
Click the white valve into the pump
body, so that it fits securely into the
small round hole. Make sure the pointed
side of the valve is facing down.
Fit the clear silicone diaphragm into the
pump body. Ensure a perfect seal around
the rim by pressing down with your fingers.
(This is easier if assembled while the
diaphragm is wet.)
10
Parts you will need for steps 1-4:
White valve Silicone diaphragm
4
Fit the Let-down Massage Cushion™ onto the
pump funnel. Secure the rim of the Let-down
Massage Cushion around the funnel, so that
there are no gaps. (This is easier if assembled
while the Let-down Massage Cushion is wet.)
Some women may prefer to use the pump
without the Let-down Massage Cushion.
Let-down Massage Cushion has petals that
flex in and out to gently massage the area
around the breast.This is intended to help
stimulate a fast, natural milk flow. When using
the breast pump without Let-down Massage
Cushion, the maximum vacuum level
achievable will be higher.
To ensure that the pump is
completely stable,insert the
pump base into the stand.
Let-down Massage Cushion™White stand
3
Screw the pump body onto the
reusable base until securely in place.
Pump body
Reusable base
9
Assembling the Pump Body of the ISIS iQ UNO
Before assembling, make sure that you have correctly washed and sanitized
the pump. See section titled ‘Cleaning and Sanitizing ISIS iQ’ on page 6.
HELPFUL TIP!
Batteries will last for approximately 6 hours. The light
on the control handle will display a slow pulsing
flash to warn you when it is time to replace them.
There will be enough power for approximately
1 more pumping session, with no drop-off in
performance, before the pump switches itself off.
HELPFUL TIP!
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
11
Connecting the Electronics of ISIS iQ UNO
5
Firmly push the control handle onto
the pump body so that it sits securely
on top of the silicone diaphragm.
6
For electric use connect the wall
plug cord to the control handle and
plug into an electrical wall outlet.
12
Connecting the Electronics of ISIS iQ UNO
7
For battery use, slide the top
off the battery pack and insert
4 x AA batteries.
Parts you will need for steps 5-9:
8
Connect the power cord to
the control handle.
9
Switch on using button found
on top of the battery pack.
Control handle
Battery pack
Wall plug cord
i
Assembled
pump body
(see pages 9-10)
Pumping with ISIS iQ UNO
14
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
13
Pumping with ISIS iQ UNO
Before you begin pumping, make sure that you have correctly washed, sanitized and
assembled the pump. Consult the ‘Preparing to Pump’ Section on page 7 for tips on
stimulating let-down and milk flow.
4
3
2
1
5
Wash your hands thoroughly and make sure your
breasts are clean.
Turn on Pump: (Either plug in the wall plug cord or
switch on at the on/off switch located on the battery
pack.) Press and hold the control button for a few
seconds.When the light turns GREEN, the pump
is ready to use.
If the light is flashing RED, refer to the
‘Troubleshooting Guide’ on page 21-22.
Form a Seal: Press the pump against your breast,
so that your nipple fits into the funnel. A seal should
form between the pump and your breast.
Let-down: Let-down is your body’s physiological
response to the suckling action of your baby on the
breast.This stimulates the breast to produce milk and
send it towards the nipple where it is available for baby.
To initiate Let-down, begin by squeezing the handle
with shallow quick strokes.This is intended to imitate
your baby’s natural suckling pattern. At the same time
you are doing this, you are enabling the petals on the
Let-down Massage Cushion™to flex in and out around
the areola, creating a massaging effect.This is intended
to help stimulate the natural Let-down reflex. Let-down
can occur immediately after a few strokes and should
not take longer than 5 minutes (refer to page 7 on
Preparing to Pump).You can choose to automate this
Let-down phase by pressing the blue One-touch
Memory Control or you can continue to pump manually.
Milk Expression: Milk Expression occurs after
Let-down is achieved and milk begins to flow.
It is the phase that is induced by the baby’s
deeper more comfortable sucking rhythm.
If you did not automate the Let-down rhythm,
please skip to Step 5. If you have automated
the Let-down phase in Step 3, press the blue
One-touch Memory Control to end the Let-
down rhythm. You can now begin to establish
a comfortable pumping rhythm and level of
suction that can be maintained throughout your
pumping session.
ISIS iQ Mimics Your Pumping:To create a natural
breastfeeding rhythm, we suggest you hold down
on the handle for 3 seconds, then release and repeat
the pattern for the next compression. Next, press
the blue One-touch Memory Control on the handle.
The mode light on the pump motor will change
from
GREEN
to
ORANGE
and ISIS iQ will mimic the
rhythm of the last two compressions.
Note: You do not need to compress the handle fully, only
until it feels comfortable.The further you compress the
handle,the more suction the pump will provide.If the
pressure is uncomfortable, stop the automated pumping
by pressing the One-touch Memory Control and break the
seal between your breast and pump funnel with your finger.
7
8
6
CONSULT THE GUIDELINES FOR STORING EXPRESSED BREAST MILK ON PAGE 19
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
15
Pumping with ISIS iQ UNO
Changing the Speed and Level of Suction: Press the
blue One-touch Memory Control on the handle again,
and the pump will revert to manual control. The light
will turn from ORANGE to GREEN. Establish a
comfortable speed and level of suction. Press the blue
One-touch Memory Control again, and ISIS iQ will
continue the same pumping rhythm.
Ending Pumping Session: Press the blue One-touch
Memory Control, break the seal between your breast
and pump funnel with your finger and remove the
pump from your breast.Turn the pump off and
unplug at the power source. ISIS iQ will remember
and save the speed and suction level of your last
two compressions. Unscrew the base after milk is
collected. If any milk remains in the pump body, pour
it into the base. Do Not overfill the base.Wash and
re-sanitize all necessary parts before the next use.
Next time you turn your pump on: Resuming Saved
Session? Turn on the pump as in Step 1. Complete
Step 2. Press the blue One-Touch Memory Control.
This engages the automatic pumping mode.The
pump will continue with the rhythm of the last two
saved compressions of the milk expression phase.
Continue pumping as described in Step 4. Need to
re-establish let-down? If you need to establish let-
down, turn on the pump as in Step 1. Complete
Step 2. Squeeze the handle with shallow quick
strokes and proceed as described in Step 3.
ISIS Manual Pump – Parts Guide
16
Clear pump cover
Forked handle
While the ISIS Manual Pump uses many of the same parts as the ISIS iQ UNO,
please note the parts shaded in green are specific to the ISIS Manual Pump.
Parts specific to the ISIS
Manual Pump are included
in a separate bag:
Cleaning the ISIS Manual Pump
CAUTION: DO NOT USE ANTIBACTERIAL CLEANERS OR DETERGENTS
WHEN CLEANING BREAST PUMP PARTS.
Every time before use (including first use):
Clean all parts of the ISIS Manual Pump on the top rack
of the dishwasher, or in warm soapy water and rinse.
The pump should be sanitized after every use. All parts
of the ISIS Manual Breast Pump are sterilizer safe. Sanitize
ISIS Manual in a Steam Sterilizer (Electronic, Electric or
Microwave), or by boiling in water for 10 minutes.
ISIS Manual Pump
u
u
w
c
d
e
f
g
h
w
b
b
c
d
e
f
g
h
Silicone diaphragm
White valve
Pump body
Reusable base (4oz/125ml)
Stand (same as )
Let-down Massage Cushion™
Funnel cover (same as )
h
f
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Assembling the ISIS Manual Pump
17
Assembling the ISIS Manual Pump
Wash and sanitize all parts before use. See section titled
‘Cleaning the ISIS Manual Pump’ on page 15.
18
1Wash your hands thoroughly. Click the white
valve into the pump body so that it fits
securely into the small round hole. Make sure
the pointed side of the valve is facing down.
2
3Twist the reusable base onto the pump
body until securely in place.To ensure
the pump is completely stable, insert
the pump base into the stand.
4Fit the Let-down Massage Cushion™onto the
pump funnel. Secure the rim of the Let-down
Massage Cushion around the funnel, so that
there are no gaps. (This is easier if assembled
while the Let-down Massage Cushion is wet.)
5Place the forked end of the handle
under the rounded tip of the
diaphragm stem. Push down gently
on the handle until it clicks into place.
6Click the pump cover onto the pump body.
Fit the silicone diaphragm into the pump
body. Ensure a perfect seal around the rim by
pressing down with your fingers. (This is easier
if assembled while the diaphragm is wet.)
white stand
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Before you begin pumping, make sure you have washed, sanitized and
carefully assembled the ISIS Manual Pump. Consult the ‘Preparing to Pump’
on pages 7-8 for tips about stimulating let-down and milk flow.
2019
Using the ISIS Manual Pump
2Initiate Let-down: Squeeze the handle with shallow,
quick strokes, until milk starts to flow. Do not use
full compression on the handle.
3Begin Pumping:When you see milk beginning to
flow, you can establish a comfortable pumping
rhythm and level of suction. Create a natural
breastfeeding rhythm by holding down on the
handle for 3 seconds, then releasing, and repeating
that pattern for each compression.
Note: You do not need to compress the handle fully, only
until it feels comfortable.The further you compress the
handle,the more suction the pump will provide.
4After milk is collected, unscrew the pump body
from the base.
CAUTION: DO NOT CONTINUE PUMPING FOR MORE THAN
FIVE MINUTES AT A TIME IF NO RESULT IS ACHIEVED.
TRY EXPRESSING AT ANOTHER TIME DURING THE DAY.
4After milk is collected, unscrew the pump body
from the base.
CAUTION: DO NOT CONTINUE PUMPING FOR MORE THAN
FIVE MINUTES AT A TIME IF NO RESULT IS ACHIEVED.
TRY EXPRESSING AT ANOTHER TIME DURING THE DAY.
1Wash your hands thoroughly and make sure your
breasts are clean.
Form a Seal: Press the pump against your breast,
so that your nipple fits into the funnel. A seal
should form between the pump and your breast.
AVENT Natural Shape Nipple
After sanitizing all parts, click the
nipple into the screw ring. Screw the
travel cover into the ring. Attach the
dome cap over the top of the nipple.
Dome cap (p)
Screw ring (r)
Nipple (q)
Travel cover (s)
Keeping Parts Clean & Compact for Travel
e
p
q
r
r
s
t
c
d
g
h
b
Pump
After sanitizing all parts, insert the white valve
and diaphragm into the pump body, then clip the
funnel cover over the Let-down Massage Cushion™.
Screw the travel cover onto the bottom of the
pump body, then put the assembled pump body
in the gray drawstring bag.
Travel cover (s) Silicone diaphragm (b)
Pump body (d) White valve (c)
Let-down Massage Cushion(g)
Funnel cover (h) (also used as a stand when pumping)
Storage Base
After sanitizing all parts, click the
sealing disc into the screw ring.
Screw the ring onto the
reusable base.
Screw ring (r)
Sealing disc (t)
Reusable base (e)
s
Storing Your Expressed Breast Milk
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
18
21
With AVENT, you never have to transfer milk
between containers because you pump,
store and feed with the same base.
By using the AVENT Natural Feeding System,
you preserve valuable nutrients that can get
lost if breast milk is transferred.
22
Technical Specifications
After expressing milk into the AVENT
reusable base, insert a sealing disc
into the screw ring and twist it onto
the base.To feed from the same base,
insert the AVENT Natural Shape
Nipple into the screw ring.
Guidelines for Storing Expressed Breast Milk
°Refrigerate breast milk immediately. Refrigerate for up to 48 hours in the
back of the refrigerator, not in the door.
°Freeze for up to 3 months, or 6 months in a zero-degree freezer.
°Frozen breast milk can be defrosted overnight in the refrigerator, thawed in
warm water or heated on the lowest setting of a bottle warmer or baby
food warmer.
°NEVER refreeze breast milk.
°
If you express small amounts of milk throughout the day, you can top up the
milk container by keeping it in the refrigerator and adding to it. Make sure the
milk is used within 48 hours of the first expression, or store it in the freezer.
°DO NOT add fresh breast milk to already frozen milk.
Note: Only milk collected with a clean pump should be stored to be fed to your
baby. Sanitize breast milk storage containers before use or express milk directly
into VIA disposable cups.
CAUTION: NEVER IMMERSE A FROZEN BOTTLE OR CUP IN BOILING WATER
AS THIS MAY CAUSE IT TO CRACK/SPLIT.
Key to product label
Symbols as featured on the rating label on the control handle.
Technical Specifications
• Mains Input Voltage 100 – 240 VAC
• Mains Input Frequency 50 – 60 Hz
• Supply voltage fluctuations not exceeding
+/- 10% of the nominal voltage
• Ambient Temperature range: +10˚C to +40˚C
• Atmospheric Pressure: 700 to 1060hPa
• Equipment rated for continuous operation
TYPE B APPLIED PART GENERAL WARNING
FOLLOW OPERATING
INSTRUCTIONS
ETL LISTED MARK –
CANADA/UNITED STATES
LISTED
3045297
CLASS II EQUIPMENT
FOR INDOOR USE ONLY
23 Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Lack of suction
No milk being
expressed
Pain when expressing
Milk is drawn up the
Let-down Massage
Cushion
Troubleshooting Guide
°Check that all the pump components have been assembled
correctly and that the white valve is positioned correctly.
°Ensure that the silicone diaphragm and Let-down Massage
Cushion™are fitted securely to the pump body and a perfect
seal is created, making sure to push the Let-down Massage
Cushion far enough down the center of the funnel.
°Make certain that the control handle is firmly in place.
°Ensure the pump is correctly assembled and that suction
is being created.
°Relax and try again, as expression may improve after practice.
°Refer to the ‘Preparing to Pump’ section on page 7.
°You may be squeezing too hard.You do not need to use
all the suction the pump can generate.Try compressing
the handle halfway.
°Try squeezing the handle more gently and remember the
2-3 second pumping rhythm.
°Consult your health professional/breastfeeding advisor.
°
Try leaning slightly forward.
°
Remove and re-fit the Let-down Massage Cushion to ensure
it is firmly attached and pushed far enough down the center
of the funnel.
°Some women may prefer to use the pump without the Let-down
Massage Cushion.The Let-down Massage Cushion has petals that
flex in and out to gently massage the area around the breast.
This is intended to stimulate a fast, natural milk flow.
24
Troubleshooting Guide
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
°
The pump must be switched off via the control button in order
to separate these parts. If the batteries go flat mid-pumping, you
may experience difficulty. Replace the batteries or connect the
pump to an electric outlet. Turn the pump on by holding down the
One-touch control for 2 seconds – the light will turn
GREEN.
Now
turn it off by holding the button for 2 seconds – the light will go off.
You can now disconnect the pump from the power supply and you
should be able to separate the parts.
°Avoid contact with antibacterial detergents/cleaners as they
can damage the plastic. Combinations of detergents, cleaning
products, sterilising solution, softened water and temperature
fluctuations may, under certain circumstances, cause the plastic
to crack. If this occurs, do not use. The pump body and breast milk
containers are dishwasher safe but food colorings may discolor
them. Follow guidelines in ‘Cleaning and Sanitizing
ISIS iQ UNO’ on pages 5-6.
Lost or broken parts °Contact AVENT for replacements.
Call 1.800.54.AVENT or visit www.aventamerica.com
°Ensure the pump is correctly assembled and switched on
with the power indicator illuminated GREEN.
°Make sure the cord between the electrical wall outlet
or battery pack and the pump is correctly connected.
Pump not responding
Pump light
flashing
°
3 flashes, delay, 3 flashes etc – if the pump stops working and the
power light is flashing RED the pump has detected a vacuum fault.
Disconnect the power and check the control handle and diaphragm
for obstructions or damage.
°
Pulsing flash – Low battery warning.You should consider replacing
the batteries.
Cracking or
discoloration
of pump parts
Difficulties in
separating the
control handle from
the pump body