Philips C240P4QPYEW/96 User Manual
Displayed below is the user manual for C240P4QPYEW/96 by Philips which is a product in the Computer Monitors category. This manual has pages.
Related Manuals
www.philips.com/welcome
C240P4
EN User manual 1
Customer care and warranty 41
Troubleshooting & FAQs 46
Table of Contents
1. Important ...............................................1
1.1 Power adapter safety Information .......1
1.2 EMC information ..........................................2
1.3 Safety precautions and maintenance .6
1.4 Notational Descriptions ............................7
1.5 Disposal of product and packing
material ...............................................................8
1.6 AntiMicrobial housing .................................9
2. Setting up the monitor .....................10
2.1 Installation ......................................................10
2.2 Operating the monitor ...........................11
2.3 Remove the Base Assembly for VESA
Mounting .........................................................14
3. Image Optimization ...........................15
3.1 SmartImageCLINIC ........................................15
3.2 Philips SmartControl Premium ..........16
3.3 SmartDesktop Guide ..............................23
4. PowerSensor™ ..................................28
7HFKQLFDO6SHFLÀFDWLRQV ....................29
5.1 Resolution & Preset Modes .................32
6. Power Management ...........................33
7. Regulatory Information .....................34
8. Customer care and warranty ..........41
8.1 Philips’ Flat Panel Monitors Pixel
Defect Policy .................................................41
8.2 Customer Care & Warranty ...............43
9. Troubleshooting & FAQs ..................46
9.1 Troubleshooting ..........................................46
9.2 SmartControl Premium FAQs ...........47
9.3 General FAQs ..............................................48
9.4 Medical FAQ .................................................50
1
1
. Importan
t
1. Important
The monitor is intended for use with Medical
Equipment to display alpha, numerical and
graphical data. The subject equipment Philips
monitor is powered by an external recognized
AC/DC adaptor. (IEC/EN60601-1).
1.1 Power adapter safety Information
Power adapter
This adapter (Manufacture: Philips, Model:
PMP60-13-1-HJ-S) is a forming part of the
monitor.
The connection of external equipments
External equipment intended for connection to
signal input/output or other connectors, shall
comply with relevant UL / IEC standard (e.g.
UL 60950 for IT equipment, UL 60601-1-1 and
ANSI/AAMI ES60601-1 / IEC 60601 series for
systems – shall comply with the standard IEC
60601-1-1, Safety requirements for medical
electrical systems.
Disconnecting Device
The mains plug or appliance coupler is used as
the disconnect device, the disconnect device
shall remain readily operable. Always completely
disconnect the power cord set from your
product whenever you are working or cleaning
on it. Do not make connections while the
power is on, because a sudden rush of power
can damage sensitive electronic components.
&ODVVLÀFDWLRQ
Degree of protection against the ingress of
water: IPX0
Equipment not suitable for use in the
presence of a flammable anesthetic mixture
with air or with oxygen or nitrous oxide.
(Non AP or APG Category)
Mode of operation: Continuous
Type of protection against electric shock:
Class I ME Equipment
No Applied part.
Shutdown Procedure
We strongly recommended that you should
shut down the system before you start to clean
any single components.
Please follow the steps below.
Close all application programs
Close operating software
Turn off power switch
Disconnect power cord set
Remove all devices
Safety Symbol Description
The following safety symbols are the further
explanations for your reference.
WLWKUHVSHFWWRHOHFWULFVKRFNÀUHDQG
mechanical hazards only in accordance with
ANSI/AAMI ES60601-1, and CAN/CSA C22.2
NO. 60601-1
Attention, consult ACCOMPANYING
DOCUMENTS.
Type of Current- AC
Dircet Current
European Community Approval,
The monitor complies with the 93/42/EEC and
2007/47/EC and conforms to the applicable
following standards: EN60601-1, EN 60601-1-2,
EN 61000-3-2 and EN 61000-3-3.
TUV Type Testing Approval,
The monitor complies with the EN60601-1
and IEC60601-1 of European Standards.
Power "ON"
Power "OFF"
Medical Equipment With respect to electric
VKRFNÀUHDQGPHFKDQLFDOKD]DUGVRQO\LQ
accordance with ANSI/AAMI ES 60601-1:2005,
and CAN/CSA C22.2 NO.60601-1:2008
Note
Caution: Use suitable mounting apparatus
to avoid risk of injury.
Use a power cord that matches the voltage
of the power outlet, which has been
approved and complies with the safety
standards of your particular country.
Make sure user does not contact SIP/SOPs
and the patient at the same time.
2
1
. Importan
t
1.2 EMC information
Guidance and manufacturer’s declaration – electromagnetic emissions – for all EQUIPMENT and
SYTEMS
7KHPRQLWRULVLQWHQGHGIRUXVHLQWKHHOHFWURPDJQHWLFHQYLURQPHQWVSHFLÀHGEHORZ7KHFXVWRPHURUWKHXVHURI
the monitor should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment – guidance
RF emissions
CISPR 11 Group 1
The monitor uses RF energy only for its internal function. Therefore, its
RF emissions are very low and are not likely to cause any interference in
nearby electronic equipment.
RF emissions
CISPR 11 Class B
The monitor is suitable for use in all establishments, including domestic
establishments and those directly connected to the public low-voltage
power supply network that supplies buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2 Class D
9ROWDJHÁXFWXDWLRQV
ÁLFNHUHPLVVLRQV
IEC 61000-3-3
Complies
3
1
. Importan
t
Guidance and manufacturer’s declaration – electromagnetic immunity – for all EQUIPMENT and
SYTEMS:
7KHPRQLWRULVLQWHQGHGIRUXVHLQWKHHOHFWURPDJQHWLFHQYLURQPHQWVSHFLÀHGEHORZ7KHFXVWRPHURUWKHXVHURI
the monitor should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment –
guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
6 kV contact
8 kV air
6 kV contact
8 kV air
Floors should be wood, concrete or
FHUDPLFWLOH,IÁRRUVDUHFRYHUHGZLWK
synthetic material, the relative humidity
should be at least 30%.
Electrical fast
transient/burst
IEC 61000-4-4
2 kV for power supply
lines
1 kV for input/output
lines
2 kV for power supply
lines
1 kV for input/output
lines
Mains power quality should be that
of a typical commercial or hospital
environment.
Surge
IEC 61000-4-5
1 kV line(s) to line(s)
2 kV line(s) to earth
1 kV line(s) to line(s)
2 kV line(s) to earth
Mains power quality should be that
of a typical commercial or hospital
environment.
interruptions and
voltage variations
on power supply
input lines
IEC 61000-4-11
<5 % UT (>95 % dip in
UT) for 0.5 cycle
40 % UT (60 % dip in
UT) for 5 cycles
70 % UT (30 % dip in
UT) for 25 cycles
<5 % UT (>95 % dip in
UT) for 5 sec
<5 % UT (>95 % dip in
UT) for 0.5 cycle
40 % UT (60 % dip in
UT) for 5 cycles
70 % UT (30 % dip in
UT) for 25 cycles
<5 % UT (>95 % dip in
UT) for 5 sec
Mains power quality should be that
of a typical commercial or hospital
environment. If the user of the monitor
requires continued operation during
power mains interruptions, it is
recommended that the monitor be
powered from an uninterruptible power
supply or a battery.
Power frequency
(50/60 Hz)
PDJQHWLFÀHOG
IEC 61000-4-8
3 A/m 3 A/m 3RZHUIUHTXHQF\PDJQHWLFÀHOGVVKRXOG
be at levels characteristic of a typical
location in a typical commercial or
hospital environment.
Note
UT is the a.c. mains voltage prior to application of the test level.
4
1
. Importan
t
Guidance and manufacturer’s declaration – electromagnetic immunity – for EQUIPMENT and
SYSTEMS that are not LIFE-SUPPORTING:
7KHPRQLWRULVLQWHQGHGIRUXVHLQWKHHOHFWURPDJQHWLFHQYLURQPHQWVSHFLÀHGEHORZ7KHFXVWRPHURUWKHXVHURI
the monitor should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment – guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3 Vrms
150 kHz to 80 MHz
3 V/m
80 MHz to 2.5 GHz
3 Vrms
3 V/m
Portable and mobile RF communications equipment
should be used no closer to any part of the monitor,
including cables, than the recommended separation
distance calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distance:
d = 1.2 ¥P
d = 1.2 ¥P 80 MHz to 800 MHz
d = 1.2 ¥P 800 MHz to 2.5 GHz
where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).
)LHOGVWUHQJWKVIURPÀ[HG5)WUDQVPLWWHUVDVGHWHUPLQHG
by an electromagnetic site survey:
a. Should be less than the compliance level in each
frequency range.
b. Interference may occur in the vicinity of equipment
marked with the following symbol:
Note
At 80 MHz and 800 MHz, the higher frequency range applies.
These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones
and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be
predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF
transmitters, an electromagnetic site survey should be considered. If the measured field strength
in the location in which the monitor is used exceeds the applicable RF compliance level above,
the monitor should be observed to verify normal operation. If abnormal performance is observed,
additional measures may be necessary, such as reorienting or relocating the monitor.
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
5
1
. Importan
t
Recommended separation distances between portable and mobile RF communications equipment
and the EQUIPMENT or SYSTEM – for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING:
The monitor is intended for use in an electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the monitor can help prevent electromagnetic interference
by maintaining a minimum distance between portable and mobile RF communications equipment
(transmitters) and the monitor as recommended below, according to the maximum output power of
the communications equipment.
Rated maximum output
power of transmitter (W)
Separation distance according to frequency of transmitter (Meter)
150 kHz to 80 MHz
d = 1.2 ¥P
80 MHz to 800 MHz
d = 1.2 ¥P
800 MHz to 2.5 GHz
d = 2.3 ¥P
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
Note
For transmitters rated at a maximum output power not listed above, the recommended
separation distance d in metres (m) can be estimated using the equation applicable to the
frequency of the transmitter, where P is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer.
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
6
1
. Importan
t
1.3 Safety precautions and
maintenance
Warnings
We strongly recommended that you should
shut down the system before you start to
clean any single components.
1RPRGLÀFDWLRQRIWKLVHTXLSPHQWLV
allowed.
Use of controls, adjustments or procedures
RWKHUWKDQWKRVHVSHFLÀHGLQWKLV
documentation may result in exposure to
shock, electrical hazards and/or mechanical
hazards.
Read and follow these instructions when
connecting and using your computer
monitor.
Operation
Please keep the monitor out of direct
sunlight, very strong bright lights and away
from any other heat source. Lengthy
exposure to this type of environment may
result in discoloration and damage to the
monitor.
Remove any object that could fall into
ventilation holes or prevent proper cooling
of the monitor’s electronics.
Do not block the ventilation holes on the
cabinet.
When positioning the monitor, make
sure the power plug and outlet are easily
accessible.
If turning off the monitor by detaching the
power cable or DC power cord, wait for 6
seconds before attaching the power cable
or DC power cord for normal operation.
Please use approved power cord provided
by Philips all the time. If your power cord
is missing, please contact with your local
service center. (Please refer to Customer
Care Consumer Information Center)
Do not subject the monitor to severe
vibration or high impact conditions during
operation.
Do not knock or drop the monitor during
operation or transportation.
Maintenance
To protect your monitor from possible
damage, do not put excessive pressure
on the monitor panel. When moving your
monitor, grasp the frame to lift; do not lift
the monitor by placing your hand or fingers
on the monitor panel.
Unplug the monitor if you are not going to
use it for an extensive period of time.
Unplug the monitor if you need to clean it
with a slightly damp cloth. The screen may
be wiped with a dry cloth when the power
is off. However, never use organic solvent,
such as, alcohol, or ammonia-based liquids
to clean your monitor.
To avoid the risk of shock or permanent
damage to the set, do not expose the
monitor to dust, rain, water, or excessive
moisture environment.
If your monitor gets wet, wipe it with dry
cloth as soon as possible.
If foreign substance or water gets in
your monitor, please turn the power off
immediately and disconnect the power
cord. Then, remove the foreign substance
or water, and send it to the maintenance
center.
Do not store or use the monitor in
locations exposed to heat, direct sunlight or
extreme cold.
In order to maintain the best performance
of your monitor and use it for a longer
lifetime, please use the monitor in a
location that falls within the following
temperature and humidity ranges.
Temperature: 10°C to 40°C
Humidity: 30% to 75%
Atmospheric pressure: 700 to 1060 hPa
7
1
. Importan
t
Important information for Burn-in/Ghost
image
Always activate a moving screen saver
program when you leave your monitor
unattended. Always activate a periodic
screen refresh application if your monitor
will display unchanging static content.
Uninterrupted display of still or static
images over an extended period may cause
“burn in”, also known as “after-imaging” or
“ghost imaging”, on your screen.
“Burn-in”, “after-imaging”, or “ghost imaging”
is a well-known phenomenon in LCD panel
technology. In most cases, the “burned in”
or “after-imaging” or “ghost imaging” will
disappear gradually over a period of time
after the power has been switched off.
Warning
Failure to activate a screen saver, or a periodic
screen refresh application may result in severe
“burn-in” or “after-image” or “ghost image”
symptoms that will not disappear and cannot be
repaired. The damage mentioned above is not
covered under your warranty.
Service
The casing cover should be opened only by
qualified service personnel.
If there is any need for any document for
repair or integration, please contact with
your local service center. (please refer to
the chapter of “Consumer Information
Center”)
For transportation information, please refer
to “Technical Specifications”.
Do not leave your monitor in a car/trunk
under direct sun light.
Note
Consult a service technician if the monitor
does not operate normally, or you are not sure
what procedure to take when the operating
instructions given in this manual have been
followed.
1.4 Notational Descriptions
The following subsections describe notational
conventions used in this document.
Notes, Cautions and Warnings
Throughout this guide, blocks of text may be
accompanied by an icon and printed in bold or
italic type. These blocks contain notes, cautions
or warnings. They are used as follows:
Note
This icon indicates important information and
tips that help you make better use of your
computer system.
Caution
This icon indicates information that tells you
how to avoid either potential damage to
hardware or loss of data.
Warning
This icon indicates the potential for bodily harm
and tells you how to avoid the problem.
Some warnings may appear in alternate formats
and may not be accompanied by an icon. In such
FDVHVWKHVSHFLÀFSUHVHQWDWLRQRIWKHZDUQLQJLV
mandated by the relevant regulatory authority.
Do not modify this equipment without
authorization of the manufacturer.
The monitor shall not be used for critical
diagnosis purpose or for life supporting system.
WARNING
TO AVOID RISK OF ELECTRIC SHOCK, THIS
EQUIPMENT MUST ONLY BE CONNECTED
TO A SUPPLY MAINS WITH PROTECTIVE
EARTH.
8
1
. Importan
t
1.5 Disposal of product and packing
material
Waste Electrical and Electronic Equipment-
WEEE
This marking on the product or on its
packaging illustrates that, under European
Directive 2012/19/EU governing used electrical
and electronic appliances, this product may
not be disposed of with normal household
waste. You are responsible for disposal of
this equipment through a designated waste
electrical and electronic equipment collection.
To determine the locations for dropping off
such waste electrical and electronic, contact
\RXUORFDOJRYHUQPHQWRIÀFHWKHZDVWHGLVSRVDO
organization that serves your household or the
store at which you purchased the product.
Your new monitor contains materials that can
be recycled and reused. Specialized companies
can recycle your product to increase the
amount of reusable materials and to minimize
the amount to be disposed of.
All redundant packing material has been
omitted. We have done our utmost to make the
packaging easily separable into mono materials.
3OHDVHÀQGRXWDERXWWKHORFDOUHJXODWLRQVRQ
how to dispose of your old monitor and packing
from your sales representative.
This symbol on the product or on its packaging
indicates that this product must not be
disposed of with your other household waste.
Instead, it is your responsibility to dispose of
your waste equipment by handing it over to
a designated collection point for the recycling
of waste electrical and electronic equipment.
The separate collection and recycling of your
waste equipment at the time of disposal will
help to conserve natural resources and ensure
that it is recycled in a manner that protects
human health and the environment. For more
information about where you can drop off
your waste equipment for recycling, please
FRQWDFW\RXUORFDOFLW\RIÀFH\RXUKRXVHKROG
waste disposal service or the shop where you
purchased the product
Taking back/Recycling Information for
Customers
Philips establishes technically and economically
viable objectives to optimize the environmental
performance of the organization's product,
service and activities.
From the planning, design and production
stages, Philips emphasizes the important of
making products that can easily be recycled. At
Philips, end-of-life management primarily entails
participation in national take-back initiatives
and recycling programs whenever possible,
preferably in cooperation with competitors,
which recycle all materials (products and related
packaging material) in accordance with all
Environmental Laws and taking back program
with the contractor company.
Your display is manufactured with high quality
materials and components which can be
recycled and reused.
To learn more about our recycling
program please visit: http://www.philips.
com/sites/philipsglobal/about/sustainability/
ourenvironment/productrecyclingservices.page.
MMD Monitors & Displays Nederland B.V.
3ULQV%HUQKDUGSOHLQWKÁRRU
1097 JB Amsterdam, The Netherlands
Disposal of Waste Equipment by Users in
Private Household in the European Union.
9
1
. Importan
t
1.6 AntiMicrobial housing
Germs have become a growing problem in
hospitals and clinical environments worldwide as
they can cause life-threatening infections. Philips
clinical review displaytake care of this challenge
by using JIS z2801 compliant antimicrobial
additive in its housing material making it an
integral part of the display housing. Your well
being along with your patients is now assured
by this protective shield that impedes the
growth of most common microorganisms such
as “Staphylococcus aureus (Gastroenteritis)”,
“Escherichia coli (EColi)” and “Klebsiella
(Pneumonia)”, for example.
Note
Alcohol should not be used to clean the
monitor as it has potential to damage or deform
the plastics and LCD screen and its relevant
coatings.
10
2. Setting up the monito
r
2. Setting up the monitor
2.1 Installation
Package contents
VGA (Optional)
DVI (Optional)
C240P4
AC/DC Adapter
Audio cable
©
2
0
1
3
K
o
n
i
n
k
l
i
j
k
e
P
h
i
l
i
p
s
N
.
V
.
A
l
l
r
i
g
h
t
s
r
e
s
e
r
v
e
d
.
U
n
a
u
t
h
o
r
i
z
e
d
d
u
p
l
i
c
a
t
i
o
n
i
s
a
v
i
o
l
a
t
i
o
n
o
f
a
p
p
l
i
c
a
b
l
e
l
a
w
s
.
M
a
d
e
a
n
d
p
r
i
n
t
e
d
i
n
C
h
i
n
a
.
V
e
r
s
i
o
n
Philips and the Philips’ Shield Emblem are registered trademarks of
Koninklijke Philips N.V. and are used under license from Koninklijke
Philips N.V.
Monitor drivers
SmartControl software
User’s Manual
使用 前请阅读使用说明
保留备用
Install the base
1. Place the monitor face down on a smooth
surface. Pay attention not to scratch or
damage the screen.
2. Snap in the base in the VESA mount area.
11
2. Setting up the monito
r
Connecting to your PC
1
2
3
4
2
34
8
5
5
6
9
6
7
USB
1 Kensington anti-theft lock
2 Audio input
3 VGA input
4 DVI input
5 DisplayPort
6 AC-DC Adapter
7 USB downstream
8 USB upstream
9 Earphone jack
Connect to PC
1. Connect the power cord to the back of
WKHPRQLWRUÀUPO\
2. Turn off your computer and unplug its
power cable.
3. Connect the monitor signal cable to the
video connector on the back of your
computer.
4. Plug the power cord of your computer
and your monitor into a nearby outlet.
5. Turn on your computer and monitor. If the
monitor displays an image, installation is
complete.
2.2 Operating the monitor
Description of the control buttons
7625 4
3
1
Switch monitor’s power ON and
OFF.
Access the OSD menu
.
&RQÀUPWKH26'DGMXVWPHQW
Adjust the OSD menu.
Set the sensor level for backlight
automatic control.
Change display format.
Return to previous OSD level.
SmartImageCLINIC
hot key
. There
are 6 modes to select: Clinical
D-Image, Text, sRGB image, Video,
Standard, Off.
12
2. Setting up the monito
r
Description of the On Screen Display
What is On-Screen Display (OSD)?
On-Screen Display (OSD) is a feature in all
Philips LCD monitors. It allows an end user to
adjust screen performance or select functions
of the monitors directly through an on-screen
instruction window. A user friendly on screen
display interface is shown as below:
2
Q
2II
Basic and simple instruction on the control
keys
In the OSD shown above, you can press
buttons at the front bezel of the monitor
to move the cursor, and press OK button to
FRQÀUPWKHFKRLFHRUFKDQJH
The OSD Menu
Below is an overall view of the structure of
the On-Screen Display. You can use this as a
reference when you want to work your way
around the different adjustments later on.
Main menu Sub menu
Picture
OSD Settings
Setup
Language
Color
Audio
Input
Power Sensor
Picture Format
Brightness
Contrast
BlackLevel
SmartResponse
Horizontal
Vertical
Transparency
OSD Time Out
Auto
V.Position
Phase
Clock
Resolution Notification
Reset
Information
Color Temperature
sRGB
User Define
VGA
DVI
DisplayPort
On
Off
SmartTxt
Pixel Orbiting
OverScan
Volume
Stand-Alone
Power On Logo
DP Audio
Mute
H.Position
Power LED
Wide Screen, 4:3
0~100
0~100
0~100
0~100
off, Fast, Faster, Fastest
0~100
0~100
Off, 1, 2, 3, 4
0, 1, 2, 3, 4
5s, 10s, 20s, 30s, 60s
On, Off
Yes, No
0~100
0~100
0~100
5000K, 6500K, 7500K,
8200K, 9300K, 11500K
Red: 0~100
Green: 0~100
Blue: 0~100
Off, On
Off, On
Off, On
Off, On
Off, On
Off, On
DP, Audio In
0~100
0, 1, 2, 3, 4
English Español, Français, Deutsch, Italiano,
Português, Русский ࿒፩ၭĭ Türkçe,
Nederlands, Svenska, Suomi, Polski, Čeština
한국어, 日本語, Maryar, Українська,
Português do Brasil,
ǼȜȜȘȞȚțȒ 㑷儊ѣᮽ
13
2. Setting up the monito
r
5HVROXWLRQQRWLÀFDWLRQ
This monitor is designed for optimal
performance at its native resolution, 1920
× 1200 @ 60 Hz. When the monitor is
powered on at a different resolution, an
alert is displayed on screen: Use 1920 ×
1200 @ 60 Hz for best results.
Display of the native resolution alert can be
switched off from Setup in the OSD (On
Screen Display) menu.
Physical Function
Tilt
20
-5
Swivel
+65
-65
Height adjustment
130mm
Pivot
3
90
0
14
2. Setting up the monito
r
2.3 Remove the Base Assembly for
VESA Mounting
Before you start disassembling the monitor base,
please follow the instructions below to avoid
any possible damage or injury.
1. Place the monitor face down on a smooth
surface. Pay attention not to scratch or
damage the screen.
2. Remove the base assembly.
Note
This monitor accepts a 100mm x 100mm
mounting interface.
(Screw type: M4x10)
100mm
100mm
15
3
. Image Optimization
3. Image Optimization
3.1 SmartImageCLINIC
What is it?
SmartImageCLINIC provides presets that
optimize display for different types of content,
dynamically adjusting brightness, contrast, color
and sharpness in real time. Whether you're
working with text applications, displaying images
or watching a video, Philips SmartImageCLINIC
delivers great optimized monitor performance.
Why do I need it?
You want a monitor that delivers optimized
display all your favorite types of content,
SmartImageCLINIC software dynamically adjust
brightness, contrast, color and sharpness in
real time to enhance your monitor viewing
experience.
How does it work?
SmartImageCLINIC is an exclusive, leading edge
Philips technology that analyzes the content
displayed on your screen. Based on a scenario
you select, SmartImageCLINIC dynamically
enhances the contrast, color saturation and
sharpness of images to enhance the contents
being displayed - all in real time with the press
of a single button.
How to enable SmartImageCLINIC
1. Press to launch the SmartImageCLINIC on
screen display.
2. Keep pressing to toggle among Clinical
D-Image, Text, sRGB image, Video, Standard,
Off.
3. The SmartImageCLINIC on screen display will
remain on screen for 5 seconds, or you can
DOVRSUHVV2.WRPDNHFRQÀUPDWLRQ
There are six modes to select: Clinical D-Image,
Text, sRGB image, Video, Standard, Off.
CLINIC
Clinical D-image
Text
Off
Video
Standard
sRGB image
l
v &OLQLFDO',PDJH
J
Monitors must show medical images
consistently with high quality in order
to achieve reliable interpretations. The
rendering of medical Grayscale images on
standard monitors is mostly inconsistent
at best, making them unsuitable for usage
in a clinical environment. Philips clinical
review displays with clinical D-image preset
are factory calibrated to give DICOM part
14 compatible Grayscale standard display
performance. By using high quality LCD
panels with LED technology, Philips offers
you consistent and reliable performance
16
3
. Image Optimization
at an affordable price point. For more
information on DICOM please visit http://
medical.nema.org/
v 7H[WIt helps improve reading of text
based application like PDF ebooks. By
using a special algorithm which increases
the contrast and boundary sharpness
of text content, the display is optimized
for a stress-free reading by adjusting the
brightness, contrast and color temperature
of the monitor.
v V5*%LPDJHsRGB is an industry standard
supported by major companies that
ensures the best possible match between
the colors displayed on your screen and
those in your printouts. The sRGB color
space is well specified and is designed to
match typical home and office viewing
conditions, rather than the darker
environment typically used for commercial
color matching.
v 9LGHRThis mode boosts up luminance
(brightness), deepens color saturation and
activates dynamic contrast. Pictures become
razor sharp. Details in darker areas of
your videos are now visible, without the
associated color washout in brighter areas,
giving you ultimate viewing experience.
v 6WDQGDUGThis preset mode switches the
Philips display to a factory standard image
default mode.
v 2IINo optimization by SmartImageCLINIC.
3.2 Philips SmartControl Premium
The new SmartControl Premium software
by Philips allows you to control your monitor
via an easy to use on-screen graphic interface.
Complicated adjustments are a thing of the
past as this user friendly software guides you
through ÀQHWXQLQJUHVROXWLRQ&RORUFDOLEUDWLRQ
Clock/Phase adjustments, RGB White point
adjustment, etc.
Equipped with latest technology in core
algorithm for fast processing and response, this
Windows compliant eye catching animated
Icon based software is ready to enhance your
experience with Philips monitors!
Installation
Follow the instruction and complete the
installation.
You can launch after installation is
completed.
If you want to launch later, you can either
click the shortcut on desktop or toolbar.
First launch -Wizard
The first time after installation of
SmartControl Premium, it will automatically
go to Wizard for first time launch.
The wizard will guide you through
adjustment your monitor performance step
by step.
You can go to Plug-in menu to launch
wizard later on as well.
17
3
. Image Optimization
You can adjust more options without
wizard by Standard pane.
Start with Standard pane
Adjust menu
Adjust Menu allows you to adjust
Brightness, Contrast, and Resolution.
You can follow the instruction and do the
adjustment.
Cancel prompts user if you want to cancel
installation.
18
3
. Image Optimization
Color menu
Color Menu allows you to adjust RGB,
Black Level, White Point, Calibration.
You can follow the instruction and do the
adjustment.
Refer to below table for sub-menu item
base on your input.
Example for Color Calibration.
1. "Show Me" starts color calibration tutorial.
2. Start - starts the 6-step color calibration
sequence.
3. Quick View loads the before/after images.
4. To return to Color home pane, click the
&DQFHO button.
5. Enable color calibration - by default is on.
If unchecked, does not allow for color
calibration to happen, dimes out start and
quick view buttons.
6. Must have patent info in calibration screen.
19
3
. Image Optimization
First Color Calibration Screen
Previous button is disabled until the second
color screen.
Next goes to the succeeding target
(6-targets).
Final next goes File > Presets pane.
Cancel closes the UI and returns to the
plug in page.
Eco Power menu
20
3
. Image Optimization
Options menu
2SWLRQV!3UHIHUHQFHV - Will only be active
when selecting Preferences from the drop-
down Options menu. On a non-supported
display capable of DDC/CI, only the Help and
Options tabs are available.
Displays current preference settings.
A checked box enables the feature. The
check box is a toggle.
Enable Context Menu on desktop is
checked (On) by default. Enable Context
menu displays SmartControl Premium
selections for Select Preset and Tune
Display in the desktop right-click context
menu. Disabled removes SmartControl
Premium from the right click context menu.
Enable Task Tray icon is checked (On) by
default. Enable context menu shows the
task tray menu for SmartControl Premium.
A right click on the task tray icon displays
the menu options for Help, Technical
Support. Check for Update, About, and Exit.
When Enable task tray menu is disabled,
the task tray icon will only display Exit.
Run at Startup is checked (On) by default.
When disabled, SmartControl Premium
will not launch at start or be in the task
tray. The only way to launch SmartControl
Premium is either from the desktop short
cut or from the program file. Any preset
set to run at startup will not load when
this box is unchecked (Disabled).
Enable transparency mode (Windows 7,
Windows 8, Vista, XP). Default is 0%
Opaque.
2SWLRQV!$XGLR - Will only be active when
selecting Volume from the drop-down Options
menu.
On a non-supported display capable of DDC/
CI, only the Help and Options tabs are available.
Option>Auto Pivot.
2SWLRQV!,QSXW - Will only be active when
selecting Input from the drop-down Options
menu. On a non-supported display capable of
DDC/CI, only the Help and Options tabs are
21
3
. Image Optimization
available. All other SmartControl Premium tabs
are not available.
Display the Source instruction pane and
current input source setting.
On single input displays, this pane will not
be visible.
2SWLRQV!7KHIW'HWHUUHQFH - Theft Deterrence
Pane will only be active when selecting Theft
Deterrence Mode from the drop-down Plug-in
menu.
To enable Theft Deterrence, click on On button
to bring up the following screen:
User can enter PIN between 4 and 9 digits
numbers only.
After entering PIN, Accept button takes
user to the pop-up dialog box on the
following page.
Minimum minutes set to 5. Slider set to 5
by default.
Does not require the display be attached
to a different host to go into Theft
Deterrence mode.
After creating PIN, the Theft Deterrence pane
will indicate Theft Deterrence Enabled and
provide PIN Options button:
Theft Deterrence Enabled is displayed.
Disable Theft Deterrence Mode opens
pane screen on next page.
PIN Options button only available after
user creates PIN, button opens secure PIN
web site.
Help menu
+HOS!8VHU0DQXDO - Will only be active when
selecting User Manual from the drop-down
Help menu. On a non-supported display
capable of DDC/CI, only the Help and Options
tabs are available.
22
3
. Image Optimization
+HOS!9HUVLRQ - Will only be active when
selecting Version from the drop- down Help
menu. On a non-supported display capable of
DDC/CI, only the Help and Options tabs are
available.
Context Sensitive menu
The Context Sensitive menu is Enabled by
default. If Enable Context Menu has been
checked in the Options>Preferences pane, then
the menu will be visible.
The Context Menu has four entries:
v 6PDUW&RQWURO3UHPLXP - When selected
the About screen is displayed.
v 6HOHFW3UHVHW - Provides a hierarchical
menu of saved presets for immediate use.
A check mark shows the currently selected
preset. Factory Preset can also be called
from the drop-down menu.
v 7XQH'LVSOD\ - Opens the SmartControl
Premium control panel.
v 6PDUW,PDJH&/,1,& - Check current settings:
Off, Clinical D-Image, Text, sRGB image,
Video, Standard.
Task Tray Menu Enabled
The task tray menu can be displayed by right-
clicking on the SmartControl Premium icon
from the task tray. Left Click will launch the
application.
7KHWDVNWUD\KDVÀYHHQWULHV
v +HOS - Access to User Manual file: Open
User Manual file using the default browser
window.
v 7HFKQLFDO6XSSRUW - Displays the tech
support page.
v &KHFNIRU8SGDWH - Takes the user to
PDI Landing and checks the user’s version
against the most current available.
v $ERXW - Displays detailed reference
information: product version, release
information, and product name.
v ([LW - Close SmartControl Premium.
To run SmartControl Premium again, either
select SmartControl Premium from Program
menu, double-click the desktop PC icon, or
restart the system.
23
3
. Image Optimization
Task Tray Menu Disabled
When the Task Tray is disabled in the preference
folder, only the Exit selection is available. To
completely remove SmartControl Premium
from the task tray, disable Run at Startup in
Options>Preferences.
Note
All the illustrations in this section are for
reference only. SmartControl software version
PLJKWEHFKDQJHGZLWKRXWQRWLÀFDWLRQ3OHDVH
DOZD\VFKHFNRIÀFLDO3RUWUDLWZHEVLWHwww.
portrait.com/dtune/phl/enu/index to download
the latest version of SmartControl software.
3.3 SmartDesktop Guide
SmartDesktop
SmartDesktop is in SmartControl Premium.
Install SmartControl Premium and select
SmartDesktop from Options.
Align to partition check box will enable
automatic alignment for the window when
dragged into the defined partition.
Select the desired partition by clicking on
the icon. The partition will be applied to
the desktop and the icon will be high-
lighted.
Identify provides a quick way to view the
grid.
Drag and Drop Windows
2QFHWKHSDUWLWLRQVDUHFRQÀJXUHGDQG$OLJQ
to partition is selected a window can be
dragged into the region and it will automatically
24
3
. Image Optimization
align. When the window and mouse cursor
are within the region, the region will become
highlighted.
Note
If the outline of the region is not visible when
dragging the window, “Show windows contents
while dragging” is disabled. To enable:
1. In Control Panel, click System.
2. Click Advanced system settings (For Vista ,
Win7, Win8 OS, this is located on the left
sidebar).
3. In Performance section, click Settings.
4. In the box, check Show window contents
while dragging, and click OK.
Other alternative path:
Vista:
Control Panel > Personalization > Window
Color and Appearance > Click "Open Classic
appearance properties for more color options"
> Click "Effects" button > check Show window
contents while dragging.
XP:
Display Properties>Appearance>Effects...>
check Show window contents while dragging.
Win 7:
No other alternative path available.
Win 8:
Windows 8 is to right click on the lower left
hand corner then select System > Advanced
System Settings (Left side bar) > Performance
section - Settings > Show Windows contents
while dragging.
Title Bar Options
Desktop partition can be accessed from the title
bar of the active window. This provides a quick
and easy way to manage the desktop as well as
sending any window to any partition without
having to drag and drop. Move the cursor into
the active window’s title bar to access the drop
down menu.
Right Click Menu
Right click on the Desktop Partition icon to
view the drop down menu.
)LQG:LQGRZV – In some cases, the user
may have sent multiple windows to the
same partition. Find Windows will show
all open windows and move the selected
window to the forefront.
'HVNWRS3DUWLWLRQ – Desktop Partition
shows the current selected partition and
allows the user to quickly change to any of
the partitions shown in the drop down.
Note
If more than one display is attached, the user
can select the targeted display to change the
partition. The highlighted icon represents the
current active partition.
25
3
. Image Optimization
,GHQWLI\3DUWLWLRQ – Displays the outline
grid on the desktop for the current parti-
tion.
$OLJQ2Q$OLJQ2II – Enables/disables the
drag and drop auto align feature.
([LW – Closes Desktop Partition and Dis-
play Tune. To re-initialize, launch Display
Tune from the start menu or short cut on
the desktop.
Left Click Menu
Left click on the Desktop Partition icon to
quickly send the active window to any partition
without having to drag and drop. Releasing the
mouse will send the window to the highlighted
partition.
Task Tray Right Click
The task tray also contains most of the features
supported in the title bar (with the exception
of automatically sending a window to any
partition).
)LQG:LQGRZV – In some cases, the user
may have sent multiple windows to the
same partition. Find Windows will show
all open windows and move the selected
window to the forefront.
'HVNWRS3DUWLWLRQ – Desktop Partition
shows the current selected partition and
allows the user to quickly change to any of
the partitions shown in the drop down.
,GHQWLI\3DUWLWLRQ – Displays the outline
grid on the desktop for the current parti-
tion.
$OLJQ2Q$OLJQ2II – Enables/disables the
drag and drop auto align feature.
26
3
. Image Optimization
6PDUW'HVNWRS3DUWLWLRQ'HÀQLWLRQV
Name Description Image
Full Desktop Applies all settings to the entire desktop.
Vertical Assesses the screen resolution and divides the display
into two evenly sized vertical regions.
)RUPDLQWDLQYHUWLFDOFRQÀJXUDWLRQ
Horizontal Assesses the screen resolution and divides the display
into two evenly sized horizontal regions.
)RUPDLQWDLQKRUL]RQWDOFRQÀJXUDWLRQ
Vertical Triple Assesses the screen resolution and divides the display
into three evenly sized vertical regions.
For 90 Partition 1 horizontal top Partition 2 horizontal
center Partition 3 horizontal bottom.
For 270 Partition 3 horizontal top Partition 2 horizontal
center Partition 1 horizontal bottom.
Vertical Split Left Assesses the screen resolution and divides the display
into two vertical regions, the left hand side is a single
region, the right hand side is split into two evenly sized
regions.
For 90 Partition 1 on top Partition 2&3 on bottomFor
270 Partition 1 on bottom Partition 2&3 on top.
27
3
. Image Optimization
Name Description Image
Vertical Split Right Assesses the screen resolution and divides the display
into two vertical regions, the right hand side is a single
region, the left hand side is split into two evenly sized
regions.
For 90 Partition 1&2 on top Partition 3 on bottom.For
270 Partition 3 on top Partition 1&2 on bottom.
Horizontal Split Top Assesses the screen resolution and divides the display
into two evenly sized horizontal regions, the top region
is single, the bottom region is spilt into two evenly sized
regions
For 90 Partition 1 on right side Vertical Partition 2&3
on left side Vertical.
For 270 Partition 1 on left side Vertical Partition 2&3 on
right side Vertical.
Horizontal Split
Bottom
Assesses the screen resolution and divides the display
into two evenly sized horizontal regions, the bottom
region is single, the top region is spilt into two evenly
sized regionsFor 90 Partition 1&2 on right side Vertical
Partition 3 on left side Vertical.For 270 Partition 1&2 on
left side Vertical Partition 3 on right side Vertical.
Even Split Assesses the screen resolution and divides the display
into four evenly sized regions.
28
4.
4.
P
owerSensor
™
4. PowerSensor™
How does it work?
PowerSensor works on principle of
transmission and reception of harmless
“infrared” signals in order to detect user-
presence.
When the user is in front of the monitor
the monitor operates normally, at the
predetermined settings that the user has
set- i.e. Brightness, contrast, color, etc
Assuming that the monitor was set to
100% of brightness for example, when the
user leaves his seat and is no longer in front
of the monitor, the monitor automatically
reduces the power consumption down to
80%.
User present in front User not present
ttaW
ttaW
Power consumption as illustrated above is for reference purpose only
Setting
Default settings
PowerSensor is designed to detect the presence
of the user located between 30 and 100 cm (12
DQGLQFKHVIURPWKHGLVSOD\DQGZLWKLQÀYH
degrees left or right of the monitor.
Custom settings
If you prefer to be in a position outside the
perimeters listed above, choose a higher
VWUHQJWKVLJQDOIRURSWLPDOGHWHFWLRQHIÀFLHQF\
The higher the setting, the stronger the
detection signal. For maximum PowerSensor
HIÀFLHQF\DQGSURSHUGHWHFWLRQSOHDVHSRVLWLRQ
yourself directly in front of your monitor.
If you choose to position yourself more
than 100 cm or 40 inches from the
monitor use the maximum detection signal
for distances up to 120 cm or 47 inches.
(Setting 4)
Since some dark colored clothing tends to
absorb infrared signals even when the user
is within 100 cm or 40 inches of the display,
step up signal strength when wearing black
or other dark clothes.
Hot key Sensor distance
3
Landscape/Portrait mode
Above illustrations are for reference purpose only
How to adjust settings
If PowerSensor is not operating correctly
inside or outside the default range, here’s how
to fine-tune detection:
Press the PowerSensor hot key
You will find the adjustment bar.
Adjust the PowerSensor detection
adjustment to Setting 4 and press OK.
Test the new setup to see if PowerSensor
properly detects you in your current
position.
PowerSensor function is designed to work
in Landscape mode (horizontal position)
only. After PowerSensor turn on it, it will
automatically turn Off if the monitor
is used in Portrait mode (90 degree/
vertical position); it will automatically turn
ON if monitor is returned to its default
Landscape position.
Note
A manually selected PowerSensor mode
will remain operational unless and until it is
readjusted or the default mode is recalled. If
\RXÀQGWKDWWKH3RZHU6HQVRULVH[FHVVLYHO\
sensitive to nearby motion for some reason,
please adjust to a lower signal strength.
29
7HFKQLFDO6SHFLÀFDWLRQ
V
5. Technical Specifications
Picture/Display
Monitor Panel Type IPS LCD
Backlight LED
Panel Size 24" W (61cm)
Aspect Ratio 16:10
Pixel Pitch 0.270 x 0.270 mm
Brightness 300 cd/m²
Contrast Ratio (typ.) 1000:1
Response time 14ms
Optimum Resolution 1920 x 1200 @ 60Hz
Viewing Angle 178° (H) / 178° (V) @ C/R > 10
Display Colors 16.7M
Vertical Refresh Rate 48 Hz - 85 Hz
Horizontal Frequency 24 kHz - 94 kHz
sRGB YES
Connectivity
Signal Input DVI(Digital), VGA( Analog), Display Port 1.2, USB2.0 x 4
Input Signal Separate Sync, Sync on Green
Audio In/Out PC audio-in,headphone out
Convenience
DICOM compatible curve Clinical D-image
Built-in speakers 2W x 2
User Convenience
OSD Languages
English, French, German, Spanish, Italian, Russian,
Simplified Chinese, Portuguese, Turkish, Dutch, Swedish, Finnish,
Polish, Czech, Korean, Japanese, Hungarian, Ukraine, Brazil
Portuguese, Greek, Traditional Chinese
Other Convenience Kensington Lock
Plug & Play Compatibility DDC/CI, sRGB, Windows 8/7/Vista/XP, Mac OSX, Linux
Stand
Tilt -5 / +20
Swivel -65/+65
Height adjustment 130mm
Pivot 90 degree
Power
On Mode 22.5 W (typ.) 48 W (Max)
Energy Consumption
(EnergyStar test method)
AC Input Voltage
at 100VAC, 50Hz
AC Input Voltage
at 115VAC, 60Hz
AC Input Voltage
at 230VAC, 50Hz
Normal Operation (typ.) 17.4 W 17.4 W 17.4 W
Sleep (Standby) 0.4 W (typ.) 0.4 W (typ.) 0.4 W (typ.)
Off (AC switch) 0W (typ.) 0W (typ.) 0W (typ.)
30
7HFKQLFDO6SHFLÀFDWLRQ
V
Heat Dissipation* AC Input Voltage
at 100VAC , 50Hz
AC Input Voltage
at 115VAC , 60Hz
AC Input Voltage
at 230VAC , 50Hz
Normal Operation 59.37 BTU/hr 59.37 BTU/hr 59.37 BTU/hr
Sleep (Standby) 1.37 BTU/hr 1.37 BTU/hr 1.37 BTU/hr
Off (AC switch) 0 BTU/hr 0 BTU/hr 0 BTU/hr
Power LED indicator On mode: White, Standby/Sleep mode: White (blinking)
Power Supply
External AC/DC Adapter: Philips/PMP60-13-1-HJ-S
Input: 100-240Vac, 47-63Hz, 1.22-0.68A
Output: 17-21Vdc, 3.53A
Monitor DC Input: 17-21Vdc, 3.53A
Dimension
Product with stand (WxHxD) 555.0X550.3X244.0 mm
Product without stand
(WxHxD) 555.0X388.0X64.8 mm
Weight
Product with stand 6.82 kg
Product without stand 4.48 kg
Product with packaging 9.65 kg
Operating Condition
Operation Condition
Temperature: 10ºC to 40ºC
Humidity: 30% to 75% RH
Atmospheric pressure: 700 to 1060 hPa
Non-operation Condition
Temperature: -20ºC to +60ºC
Humidity: 10% to 90% RH
Atmospheric pressure: 500 to 1060 hPa
MTBF 30,000hrs
Environmental
ROHS YES
EPEAT Gold (www.epeat.net)
Packaging 100% recyclable
6SHFLÀF6XEVWDQFHV 100% PVC BFR free housing
EnergyStar YES
Anti-Microbial
Anti-microbial housing / JIS Z2801 Anti-microbial housing
Compliance and standards
Regulatory Approvals &(0DUN7&2&HUWLÀHG789*6789(UJR:(((-,6=
IEC/EN60601-1-2,UL/cUL, C-Tick, IEC/EN60601-1, ISO13485
Cabinet
Color White
Finish Texture
31
7HFKQLFDO6SHFLÀFDWLRQ
V
Note
1. EPEAT Gold or Silver is valid only where Philips registers the product. Please visit www.epeat.net
for registration status in your country.
2. This data is subject to change without notice. Go to www.philips.com/support to download the
ODWHVWYHUVLRQRIOHDÁHW
32
7HFKQLFDO6SHFLÀFDWLRQ
V
5.1 Resolution & Preset Modes
Maximum Resolution
1920 x 1200 @ 60 Hz (analog input)
1920 x 1200 @ 60 Hz (digital input)
Recommended Resolution
1920 x 1200 @ 60 Hz (digital input)
H. freq (kHz) Resolution V. freq (Hz)
31.47 720x400 70.09
31.47 640x480 59.94
35.00 640x480 66.67
37.86 640x480 72.81
37.50 640x480 75.00
37.88 800x600 60.32
46.88 800x600 75.00
48.36 1024x768 60.00
60.02 1024x768 75.03
44.77 1280x720 59.86
63.89 1280x1024 60.02
79.98 1280x1024 75.03
55.94 1440x900 59.89
70.64 1440x900 74.98
64.67 1680x1050 59.88
65.29 1680x1050 59.95
66.59 1920x1080 59.93
74.04 1920x1200 59.95
67.50 1920x1080 60.00
75.00 1600x1200 60.00
Note
Please notice that your display works best at
native resolution of 1920 x 1200 @ 60Hz. For
best display quality,please follow this resolution
recommendation.
33
6
.
P
ower
M
anagemen
t
6. Power Management
If you have VESA DPM compliance display card
or software installed in your PC, the monitor
can automatically reduce its power consumption
when not in use. If an input from a keyboard,
mouse or other input device is detected,
the monitor will 'wake up' automatically. The
following table shows the power consumption
and signaling of this automatic power saving
feature:
3RZHU0DQDJHPHQW'HÀQLWLRQ
VESA
Mode Video H-sync V-sync Power Used LED Color
Active ON Yes Yes 22.5 W (typ.) White
Sleep
(Standby) OFF No No 0.4 W (typ.) White
(blink)
Switch Off OFF - - 0 W (AC switch) OFF
The following setup is used to measure power
consumption on this monitor.
Native resolution: 1920 x 1200
Contrast: 50%
Brightness: 300 nits
Color temperature: 6500k with full white
pattern
Note
This data is subject to change without notice.
34
7
. Regulatory Infomatio
n
7. Regulatory Information
Congratulations!
7KLVSURGXFWLV7&2&HUWLÀHGIRU6XVWDLQDEOH,7
7&2&HUWLÀHGLVDQLQWHUQDWLRQDOWKLUGSDUW\
VXVWDLQDELOLW\FHUWLÀFDWLRQIRU,7
SURGXFWV7&2&HUWLÀHGHQVXUHV
that the manufacture, use and
UHF\FOLQJRI,7SURGXFWVUHÁHFWHQYLURQPHQWDO
social and economic responsibility. Every TCO
&HUWLÀHGSURGXFWPRGHOLVYHULÀHGE\DQ
accredited independent test laboratory.
7KLVSURGXFWKDVEHHQYHULÀHGWRPHHWDOOWKH
FULWHULDLQ7&2&HUWLÀHGLQFOXGLQJ
Corporate Social Responsibility
Socially responsible production - working
conditions and labor law in manufacturing
country
(QHUJ\(IÀFLHQF\
Energy efficiency of product and power supply.
Energy Star compliant, where applicable
Environmental Management System
Manufacturer must be certified according to
either ISO 14001 or EMAS
Minimization of Hazardous Substances
Limits on cadmium, mercury, lead & hexavalent
chromium including requirements for mercury-
free products, halogenated substances and
hazardous flame retardants
Design for Recycling
Coding of plastics for easy recycling. Limit on
the number of different plastics used.
Product Lifetime, Product Take Back
Minimum one-year product warranty. Minimum
three-year availability of spare parts. Product
takeback
Packaging
Limits on hazardous substances in product
packaging. Packaging prepared for recycling
Ergonomic, User-centered design
Visual ergonomics in products with a display.
Adjustability for user comfort (displays,
headsets) Acoustic performance – protection
against sound spikes (headsets) and fan noise
(projectors, computers) Ergonomically designed
keyboard (notebooks)
Electrical Safety, minimal electro-magnetic
Emissions Third Party Testing
All certified product models have been tested
in an independent, accredited laboratory.
A detailed criteria set is available for download
at www.tcodevelopment.com, where you can
DOVRÀQGDVHDUFKDEOHGDWDEDVHRIDOO7&2
&HUWLÀHG,7SURGXFWV
TCO Development, the organization behind
7&2&HUWLÀHGKDVEHHQDQLQWHUQDWLRQDO
GULYHULQWKHÀHOGRI6XVWDLQDEOH,7IRU\HDUV
&ULWHULDLQ7&2&HUWLÀHGDUHGHYHORSHGLQ
collaboration with scientists, experts, users
and manufacturers. Organizations around the
ZRUOGUHO\RQ7&2&HUWLÀHGDVDWRROWRKHOS
them reach their sustainable IT goals. We are
RZQHGE\7&2DQRQSURÀWRUJDQL]DWLRQ
UHSUHVHQWLQJRIÀFHZRUNHUV7&2'HYHORSPHQW
is headquartered in Stockholm, Sweden, with
regional presence in North America and Asia.
For more information, please visit
ww.tcodevelopment.com
Technology for you and the planet
(Only for selective models)
The OFF mode of Smartimage is used for
7&2&HUWLÀHGFRPSOLDQFH
35
7
. Regulatory Infomatio
n
Lead-free Product
Lead free display promotes
environmentally sound recovery
and disposal of waste from electrical
and electronic equipment. Toxic
substances like Lead has been eliminated
and compliance with European community’s
stringent RoHs directive mandating restrictions
on hazardous substances in electrical and
electronic equipment have been adhered to
in order to make Philips monitors safe to use
throughout its life cycle.
EPEAT
(www.epeat.net)
The EPEAT (Electronic
Product Environmental
Assessment Tool) program
evaluates computer
desktops, laptops, and monitors based on 51
environmental criteria developed through
an extensive stakeholder consensus process
supported by US EPA.
EPEAT system helps purchasers in the public
and private sectors evaluate, compare and
select desktop computers, notebooks and
monitors based on their environmental
attributes. EPEAT also provides a clear and
consistent set of performance criteria for the
design of products, and provides an opportunity
for manufacturers to secure market recognition
for efforts to reduce the environmental impact
of its products.
%HQHÀWVRI(3($7
Reduce use of primary materials
Reduce use of toxic materials
Avoid the disposal of hazardous waste EPEAT’S
requirement that all registered products meet
(1(5*<67$5·VHQHUJ\HIÀFLHQF\VSHFLÀFDWLRQV
means that these products will consume less
energy throughout their life.
CE Declaration of Conformity
This product is in conformity with the following
standards
EN60950-1:2006+A11:2009+A1:20
10+A12:2011 (Safety requirement of
Information Technology Equipment)
EN55022:2010 (Radio Disturbance
requirement of Information Technology
Equipment)
EN55024:2010 (Immunity requirement of
Information Technology Equipment)
EN61000-3-2:2006 +A1:2009+A2:2009
(Limits for Harmonic Current Emission)
EN61000-3-3:2008 (Limitation of Voltage
Fluctuation and Flicker) following provisions
of directives applicable.
EN60601-1-2:2007 (Medical electrical
equipment. General requirements for
safety Collateral standard, Electromagnetic
compatibility Requirements and tests)
2006/95/EC (Low Voltage Directive)
2004/108/EC (EMC Directive)
2009/125/EC (ErP Directive, EC No.
1275/2008 Implementing Directive
for Standby and Off mode power
consumption)
2011/65/EU (RoHS Directive)
and is produced by a manufacturing organization
on ISO9000 level.
ISO9241-307:2008 (Ergonomic
requirement, Analysis and compliance test
methods for electronic visual displays)
GS EK1-2000:2013 (GS mark requirement)
TUV IEC60601-1 (EN 60601-1:2006
Medical electrical equipment - Part 1:
General requirements for basic safety and
essential performance)
EN 60601-1-2:2007 Medical electrical
equipment - Part 1-2: General
requirements for basic safety and
essential performance - Collateral
standard: Electromagnetic compatibility -
Requirements and tests
36
7
. Regulatory Infomatio
n
Energy Star Declaration
(www.energystar.gov)
As an ENERGY STAR® Partner, we
have determined that this product
meets the ENERGY STAR®
JXLGHOLQHVIRUHQHUJ\HIÀFLHQF\
1RWH
We recommend you switch off the monitor
when it is not in use for a long time.
However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does cause
harmful interference to radio or television
reception, which can be determined by
turning the equipment off and on, the
user is encouraged to try to correct
the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the
equipment and receiver.
Connect the equipment into an outlet on
a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced
radio/TV technician for help.
&KDQJHVRUPRGLÀFDWLRQVQRWH[SUHVVO\
approved by the party responsible for
compliance could void the user's authority
to operate the equipment.
Use only RF shielded cable that was supplied
with the monitor when connecting this monitor
to a computer device.
7RSUHYHQWGDPDJHZKLFKPD\UHVXOWLQÀUHRU
shock hazard, do not expose this appliance to
rain or excessive moisture.
THIS CLASS B DIGITAL APPARATUS MEETS
ALL REQUIREMENTS OF THE CANADIAN
INTERFERENCE-CAUSING EQUIPMENT
REGULATIONS.
FCC Declaration of Conformity
Declaration of Conformity for Products Marked
with FCC Logo,
United States Only
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Commission Federale de la Communication
(FCC Declaration)
Cet équipement a été testé et déclaré
conforme auxlimites des appareils
numériques de class B,aux termes de
l'article 15 Des règles de la FCC. Ces
limites sont conçues de façon à fourir
une protection raisonnable contre les
interférences nuisibles dans le cadre d'une
installation résidentielle.
CET appareil produit, utilise et peut émettre
des hyperfréquences qui, si l'appareil n'est
pas installé et utilisé selon les consignes
données, peuvent causer des interférences
nuisibles aux communications radio.
Cependant, rien ne peut garantir l'absence
d'interférences dans le cadre d'une
installation particulière. Si cet appareil est
la cause d'interférences nuisibles pour
la réception des signaux de radio ou de
télévision, ce qui peut être décelé en
fermant l'équipement, puis en le remettant
en fonction, l'utilisateur pourrait essayer de
corriger la situation en prenant les mesures
suivantes:
Réorienter ou déplacer l’antenne de
réception.
Augmenter la distance entre l’équipement
et le récepteur.
37
7
. Regulatory Infomatio
n
Brancher l’équipement sur un autre circuit
que celui utilisé par le récepteur.
Demander l’aide du marchand ou d’un
technicien chevronné en radio/télévision.
7RXWHVPRGLÀFDWLRQVQD\DQWSDVUHoX
l'approbation des services compétents
en matière de conformité est susceptible
d'interdire à l'utilisateur l'usage du présent
équipement.
N'utiliser que des câbles RF armés pour
les connections avec des ordinateurs ou
périphériques.
CET APPAREIL NUMERIQUE DE LA CLASSE
B RESPECTE TOUTES LES EXIGENCES DU
REGLEMENT SUR LE MATERIEL BROUILLEUR
DU CANADA.
EN 55022 Compliance (Czech Republic Only)
3ROLVK&HQWHUIRU7HVWLQJDQG&HUWLÀFDWLRQ
Notice
The equipment should draw power from a
socket with an attached protection circuit (a
three-prong socket). All equipment that works
together (computer, monitor, printer, and so on)
should have the same power supply source.
The phasing conductor of the room's electrical
installation should have a reserve short-circuit
protection device in the form of a fuse with a
nominal value no larger than 16 amperes (A).
To completely switch off the equipment, the
power supply cable must be removed from the
power supply socket, which should be located
near the equipment and easily accessible.
$SURWHFWLRQPDUN%FRQÀUPVWKDWWKH
equipment is in compliance with the protection
usage requirements of standards PN-93/T-42107
and PN-89/E-06251.
North Europe (Nordic Countries) Information
Placering/Ventilation
9$51,1*
FÖRSÄKRA DIG OM ATT HUVUDBRYTARE
OCH UTTAG ÄR LÄTÅTKOMLIGA, NÄR
DU STÄLLER DIN UTRUSTNING PÅPLATS.
Placering/Ventilation
$'9$56(/
SØRG VED PLACERINGEN FOR, AT
NETLEDNINGENS STIK OG STIKKONTAKT
ER NEMT TILGÆNGELIGE.
Paikka/Ilmankierto
9$52,786
SIJOITA LAITE SITEN, ETTÄ VERKKOJOHTO
VOIDAAN TARVITTAESSA HELPOSTI
IRROTTAA PISTORASIASTA.
Plassering/Ventilasjon
$'9$56(/
NÅR DETTE UTSTYRET PLASSERES, MÅ
DU PASSE PÅ AT KONTAKTENE FOR
STØMTILFØRSEL ER LETTE Å NÅ.
BSMI Notice (Taiwan Only)
38
7
. Regulatory Infomatio
n
Ergonomie Hinweis (nur Deutschland)
Der von uns gelieferte Farbmonitor entspricht
den in der "Verordnung über den Schutz vor
Schäden durch Röntgenstrahlen" festgelegten
Vorschriften.
$XIGHU5FNZDQGGHV*HUlWHVEHÀQGHWVLFK
ein Aufkleber, der auf die Unbedenklichkeit der
Inbetriebnahme hinweist, da die Vorschriften
über die Bauart von Störstrahlern nach Anlage
,,,ʔ$EVGHU5|QWJHQYHURUGQXQJHUIOOWVLQG
Damit Ihr Monitor immer den in der Zulassung
geforderten Werten entspricht, ist darauf zu
achten, daß
1. Reparaturen nur durch Fachpersonal
durchgeführt werden.
2. nur original-Ersatzteile verwendet werden.
3. bei Ersatz der Bildröhre nur eine
bauartgleiche eingebaut wird.
Aus ergonomischen Gründen wird empfohlen,
die Grundfarben Blau und Rot nicht auf
dunklem Untergrund zu verwenden (schlechte
Lesbarkeit und erhöhte Augenbelastung bei zu
geringem Zeichenkontrast wären die Folge).
Der arbeitsplatzbezogene Schalldruckpegel
nach DIN 45 635 beträgt 70dB (A) oder
weniger.
ACHTUNG: BEIM AUFSTELLEN
DIESES GERÄTES DARAUF
ACHTEN, DAß NETZSTECKER UND
NETZKABELANSCHLUß LEICHT
ZUGÄNGLICH SIND.
Restriction on Hazardous Substances
statement (India)
This product complies with the “India E-waste
Rule 2011” and prohibits use of lead, mercury,
hexavalent chromium, polybrominated
biphenyls or polybrominated diphenyl ethers
in concentrations exceeding 0.1 weight % and
0.01 weight % for cadmium, except for the
exemptions set in Schedule 2 of the Rule.
E-Waste Declaration for India
This symbol on the product or on its packaging
indicates that this product must not be
disposed of with your other household waste.
Instead it is your responsibility to dispose of
your waste equipment by handing it over to
a designated collection point for the recycling
of waste electrical and electronic equipment .
The separate collection and recycling of your
waste equipment at the time of disposal will
help to conserve natural resources and ensure
that it is recycled in a manner that protects
human health and the environment. For more
information about where you can drop off your
waste equipment for recycling in India please
visit the below web link.
http://www.india.philips.com/about/sustainability/
recycling/index.page
39
7
. Regulatory Infomatio
n
Information for U.K. only
WARNING - THIS APPLIANCE MUST BE
EARTHED.
Important:
This apparatus is supplied with an approved
moulded 13A plug. To change a fuse in this type
of plug proceed as follows:
1. Remove fuse cover and fuse.
2. Fit new fuse which should be a BS 1362
5A,A.S.T.A. or BSI approved type.
3. Retit the fuse cover.
,IWKHÀWWHGSOXJLVQRWVXLWDEOHIRU\RXUVRFNHW
outlets, it should be cut off and an appropriate
SLQSOXJÀWWHGLQLWVSODFH
If the mains plug contains a fuse, this should
have a value of 5A. If a plug without a fuse is
used, the fuse at the distribution board should
not be greater than 5A.
NOTE: The severed plug must be destroyed
to avoid a possible shock hazard
should it be inserted into a 13A socket
elsewhere.
(A)
(B)
How to connect a plug
The wires in the mains lead are coloured in
accordance with the following code:
BLUE -“NEUTRAL”(“N”)
BROWN -“LIVE”(“L”)
GREEN&YELLOW -“EARTH”(“E”)
1. The GREEN&YELLOW wire must be
connected to the terminal in the plug
which is marked with the letter "E" or by
the Earth symbol or coloured GREEN or
GREEN&YELLOW.
2. The BLUE wire must be connected to the
terminal which is marked with the letter
"N" or coloured BLACK.
3. The BROWN wire must be connected
to the terminal which is marked with the
letter "L" or coloured RED.
Before replacing the plug cover, make certain
that the cord grip is clamped over the sheath of
the lead - not simply over the three wires.
㧊ٻ₆₆⓪ٻṖ㩫㣿ڃڝ ڄٻ㩚㧦䕢ٻ 㩗䞿ٻ ₆
₆⪲㍲ٻ㭒⪲ٻṖ㩫㠦㍲ٻ㌂㣿䞮⓪ٻộ㦚ٻ⳿
㩗㦒⪲ٻ䞮Ⳇڇٻ⳾✶ٻ㰖㡃㠦㍲ٻ ㌂㣿䞶ٻ 㑮ٻ
㧞㔋┞┺ډ
40
7
. Regulatory Infomatio
n
VCCI-B
౾Ȃ·ρΑCૂ༭ܿ౾ȃ
౾Ȃزೳ۪ޏঀဥ
࿒എȂ౾ρΐ
ΞτΫΐοϋܥ߃୪ঀဥ
Ȃવٺ֨ܳ
ȃ
৾ե୰ྶୃ৾ե
ئȃ
粗分類
化学物質表
Pb Hg Cd Cr6+ PBBs PBDEs
前面ベゼル OOOOOO
背面カバー OOOOOO
スタンド OOOOOO
LCDパネル
WLED 適用除
外の OOOOO
CCFL 適用除
外の
適用除
外の OOOO
PCBA 適用除
外の OOOOO
ケーブル&ワイヤ 適用除
外の OOOOO
リモコン 適用除
外の OOOOO
*:PCBAはベア印刷回路基板、で構成され、はんだ付けおよび抵抗器、コンデ
ンサ、アレー、コネクタ、チップなど、その表面実装エレメントで構成されま
す。
注1:「O」は、計算される物質の含有率が参照含有率を超えていないことを示
します。
注2:「適用除外」項目は、特定の化学物質がJISC0950の規格により適用除外
とされた項目に対応することを意味します。
JISC0950
China RoHS
The People's Republic of China released a
regulation called "Management Methods for
Controlling Pollution by Electronic Information
Products" or commonly referred to as China
RoHS. All products produced and sold for China
market have to meet China RoHS request.
ѝഭ⭥ᆀؑӗ૱⊑ḃ᧗ࡦḷ䇶㾱≲ѝഭ
RoHS⌅㿴ḷ⽪㾱≲ӗ૱ѝᴹ∂ᴹᇣ⢙䍘ᡆ
ݳ㍐Ⲵ〠৺䟿
䜘Ԧ〠
ᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐
䫵
(Pb)
⊎
(Hg)
䭹
(Cd)
ޝԧ䬜
(Cr6+)
ཊⓤ㚄㤟
(PBB)
ཊⓤҼ㤟䟊
(PBDE)
ཆ༣ OOO O O O
⏢Ღᱮ⽪ቿ⚟㇑ XOO O O O
⭥䐟ᶯ㓴ԦXOO O O O
⭥Ⓚ䘲䝽㓯 XOO O O O
⭥Ⓚ㓯䘎᧕㓯 XOO O O O
*:
⭥䐟ᶯ㓴Ԧᤜঠࡧ⭥䐟ᶯ৺ަᶴᡀⲴ䴦䜘Ԧˈྲ⭥䱫ǃ⭥ᇩǃ䳶ᡀ⭥
䐟ǃ䘎᧕ಘㅹDŽ
O:
㺘⽪䈕ᴹ∂ᴹᇣ⢙䍘൘䈕䜘Ԧᡰᴹ൷䍘ᶀᯉѝⲴ䟿൷൘ljňŃİŕijķĶĸijĮ
ijıIJIJ㿴ᇊⲴ䲀䟿㾱≲ԕлDŽ
X:
㺘⽪䈕ᴹ∂ᴹᇣ⢙䍘㠣ቁ൘䈕䜘ԦⲴḀа൷䍘ᶀᯉѝⲴ䟿䎵ࠪňŃİ
ŕijķĶĸijĮijıIJIJ㿴ᇊⲴ䲀䟿㾱≲˗նᱟк㺘ѝᢃ“X”Ⲵ䜘Ԧˈㅖ⅗ⴏRoHS⌅
㿴㾱≲˄Ҿ䉱ݽⲴ䜘࠶˅DŽ
⧟؍֯⭘ᵏ䲀
↔ḷ䇶ᤷᵏ䲀ᒤ⭥ᆀؑӗ૱ѝᴹ
Ⲵᴹ∂ᴹᇣ⢙䍘ᡆݳ㍐൘↓ᑨ֯⭘ⲴᶑԦ
лнՊ⭏ཆ⋴ᡆケ⭥ᆀؑӗ૱⭘ᡧ
֯⭘䈕⭥ᆀؑӗ૱нՊሩ⧟ຳ䙐ᡀѕ䟽
⊑ḃᡆሩަӪ䓛ǃ䍒ӗ䙐ᡀѕ䟽ᦏᇣⲴᵏ
䲀DŽ
ljᓏᔳ⭥ಘ⭥ᆀӗ૱എ᭦༴⨶㇑⨶ᶑֻNJ
ᨀ⽪ᙗ䈤᰾
ѪҶᴤྭൠޣ⡡৺؍ᣔൠ⨳ˈᖃ⭘ᡧн
䴰㾱↔ӗ૱ᡆӗ૱ሯભ㓸→ᰦˈ䈧䚥ᆸഭ
ᇦᓏᔳ⭥ಘ⭥ᆀӗ૱എ᭦༴⨶ޣ⌅ᖻ⌅
㿴ˈሶަӔ㔉ᖃൠާᴹഭᇦ䇔Ⲵഎ᭦༴
⨶䍴䍘Ⲵল୶䘋㹼എ᭦༴⨶DŽ
41
8. Customer care and warranty
8. Customer care and
warranty
8.1 Philips’ Flat Panel Monitors Pixel
Defect Policy
Philips strives to deliver the highest quality
products. We use some of the industry's most
advanced manufacturing processes and practice
stringent quality control. However, pixel or
sub pixel defects on the TFT Monitor panels
XVHGLQÁDWSDQHOPRQLWRUVDUHVRPHWLPHV
unavoidable. No manufacturer can guarantee
that all panels will be free from pixel defects,
but Philips guarantees that any monitor with an
unacceptable number of defects will be repaired
or replaced under warranty. This notice explains
WKHGLIIHUHQWW\SHVRISL[HOGHIHFWVDQGGHÀQHV
acceptable defect levels for each type. In order
to qualify for repair or replacement under
warranty, the number of pixel defects on a TFT
Monitor panel must exceed these acceptable
levels. For example, no more than 0.0004% of
the sub pixels on a monitor may be defective.
Furthermore, Philips sets even higher quality
standards for certain types or combinations
of pixel defects that are more noticeable than
others. This policy is valid worldwide.
subpixel
pixel
Pixels and Sub pixels
A pixel, or picture element, is composed of
three sub pixels in the primary colors of red,
green and blue. Many pixels together form an
image. When all sub pixels of a pixel are lit, the
three colored sub pixels together appear as a
single white pixel. When all are dark, the three
colored sub pixels together appear as a single
black pixel. Other combinations of lit and dark
sub pixels appear as single pixels of other colors.
Types of Pixel Defects
Pixel and sub pixel defects appear on the screen
in different ways. There are two categories of
pixel defects and several types of sub pixel
defects within each category.
Bright Dot Defects
Bright dot defects appear as pixels or sub pixels
that are always lit or 'on'. That is, a bright dot is
a sub-pixel that stands out on the screen when
the monitor displays a dark pattern. There are
the types of bright dot defects.
One lit red, green or blue sub pixel.
Two adjacent lit sub pixels:
- Red + Blue = Purple
- Red + Green = Yellow
- Green + Blue = Cyan (Light Blue)
Three adjacent lit sub pixels (one white pixel).
42
8. Customer care and warranty
Note
A red or blue bright dot must be more than 50
percent brighter than neighboring dots while
a green bright dot is 30 percent brighter than
neighboring dots.
Black Dot Defects
Black dot defects appear as pixels or sub pixels
that are always dark or 'off'. That is, a dark dot is
a sub-pixel that stands out on the screen when
the monitor displays a light pattern. These are
the types of black dot defects.
Proximity of Pixel Defects
Because pixel and sub pixels defects of the
same type that are near to one another may be
PRUHQRWLFHDEOH3KLOLSVDOVRVSHFLÀHVWROHUDQFHV
for the proximity of pixel defects.
Pixel Defect Tolerances
In order to qualify for repair or replacement
due to pixel defects during the warranty period,
D7)70RQLWRUSDQHOLQD3KLOLSVÁDWSDQHO
monitor must have pixel or sub pixel defects
exceeding the tolerances listed in the following
tables.
BRIGHT DOT DEFECTS ACCEPTABLE LEVEL
1 lit subpixel 3
2 adjacent lit subpixels 1
3 adjacent lit subpixels (one white pixel) 0
Distance between two bright dot defects* >15mm
Total bright dot defects of all types 3
BLACK DOT DEFECTS ACCEPTABLE LEVEL
1 dark subpixel 5 or fewer
2 adjacent dark subpixels 2 or fewer
3 adjacent dark subpixels 0
Distance between two black dot defects* >15mm
Total black dot defects of all types 5 or fewer
TOTAL DOT DEFECTS ACCEPTABLE LEVEL
Total bright or black dot defects of all types 5 or fewer
Note
1. 1 or 2 adjacent sub pixel defects = 1 dot defect
2. This monitor is ISO9241-307 compliant. (ISO9241-307: Ergonomic requirement,analysis and
compliance test methods for electronic visual displays)
3. ISO9241-307 is the successor of formerly known ISO13406 standard, which is withdrawn by the
International Organisation for Standardisation (ISO) per: 2008-11-13.
43
8. Customer care and warranty
8.2 Customer Care & Warranty
For warranty coverage information and additional support requirement valid for your region, please visit
www.philips.com/support website for details. You may also contact your local Philips Customer Care
Center number listed below.
Contact Information for WESTERN EUROPE region:
&RXQWU\ &63 +RWOLQH1XPEHU 3ULFH 2SHQLQJ+RXUV
Austria RTS +43 0810 000206 € 0.07 Mon to Fri : 9am - 6pm
Belgium Ecare +32 078 250851 € 0.06 Mon to Fri : 9am - 6pm
Cyprus Alman 800 92 256 Free of charge Mon to Fri : 9am - 6pm
Denmark Infocare +45 3525 8761 Local call tariff Mon to Fri : 9am - 6pm
Finland Infocare +358 09 2290 1908 Local call tariff Mon to Fri : 9am - 6pm
France Mainteq +33 082161 1658 € 0.09 Mon to Fri : 9am - 6pm
Germany RTS +49 01803 386 853 € 0.09 Mon to Fri : 9am - 6pm
Greece Alman +30 00800 3122 1223 Free of charge Mon to Fri : 9am - 6pm
Ireland Celestica +353 01 601 1161 Local call tariff Mon to Fri : 8am - 5pm
Italy Anovo Italy +39 840 320 041 € 0.08 Mon to Fri : 9am - 6pm
Luxembourg Ecare +352 26 84 30 00 Local call tariff Mon to Fri : 9am - 6pm
Netherlands Ecare +31 0900 0400 063 € 0.10 Mon to Fri : 9am - 6pm
Norway Infocare +47 2270 8250 Local call tariff Mon to Fri : 9am - 6pm
Poland MSI +48 0223491505 Local call tariff Mon to Fri : 9am - 6pm
Portugal Mainteq 800 780 902 Free of charge Mon to Fri : 8am - 5pm
Spain Mainteq +34 902 888 785 € 0.10 Mon to Fri : 9am - 6pm
Sweden Infocare +46 08 632 0016 Local call tariff Mon to Fri : 9am - 6pm
Switzerland ANOVO CH +41 02 2310 2116 Local call tariff Mon to Fri : 9am - 6pm
United Kingdom Celestica +44 0207 949 0069 Local call tariff Mon to Fri : 8am - 5pm
Contact Information for China:
&RXQWU\ &DOOFHQWHU &RQVXPHUFDUHQXPEHU
China PCCW Limited 4008 800 008
Contact Information for NORTH AMERICA :
&RXQWU\ &DOOFHQWHU &RQVXPHUFDUHQXPEHU
U.S.A. EPI-e-center (877) 835-1838
Canada EPI-e-center (800)479-6696
44
8. Customer care and warranty
Contact Information for CENTRAL AND EASTERN EUROPE region:
&RXQWU\ &DOOFHQWHU &63 &RQVXPHUFDUHQXPEHU
Belarus NA IBA +375 17 217 3386
+375 17 217 3389
Bulgaria NA LAN Service +359 2 960 2360
Croatia NA MR Service Ltd +385 (01) 640 1111
Czech Rep. NA Asupport 420 272 188 300
Estonia NA FUJITSU +372 6519900(General)
+372 6519972(workshop)
Georgia NA Esabi +995 322 91 34 71
Hungary NA Profi Service
+36 1 814 8080(General)
+36 1814 8565(For AOC&Philips
only)
Kazakhstan NA Classic Service I.I.c. +7 727 3097515
Latvia NA ServiceNet LV +371 67460399
+371 27260399
Lithuania NA UAB Servicenet +370 37 400160(general)
+370 7400088 (for Philips)
Macedonia NA AMC +389 2 3125097
Moldova NA Comel +37322224035
Romania NA Skin +40 21 2101969
Russia NA CPS +7 (495) 645 6746
Serbia&Montenegro NA Kim Tec d.o.o. +381 11 20 70 684
Slovakia NA Datalan Service +421 2 49207155
Slovenia NA PC H.and +386 1 530 08 24
the republic of Belarus NA ServiceBy + 375 17 284 0203
Turkey NA Tecpro +90 212 444 4 832
Ukraine NA Topaz +38044 525 64 95
Ukraine NA Comel +380 5627444225
Contact Information for LATIN AMERICA region:
&RXQWU\ &DOOFHQWHU &RQVXPHUFDUHQXPEHU
Brazil Vermont 0800-7254101
Argentina 0800 3330 856
45
8. Customer care and warranty
Contact Information for APMEA region:
&RXQWU\ $63 &RQVXPHUFDUHQXPEHU 2SHQLQJKRXUV
Australia AGOS NETWORK PTY LTD 1300 360 386 Mon.~Fri. 9:00am-5:30pm
New Zealand Visual Group Ltd. 0800 657447 Mon.~Fri. 8:30am-5:30pm
Hong Kong
Macau
Company: Smart Pixels
Technology Ltd.
Hong Kong:
Tel: +852 2619 9639
Macau:Tel: (853)-0800-987
Mon.~Fri. 9:00am-6:00pm
Sat. 9:00am-1:00pm
India REDINGTON INDIA LTD Tel: 1 800 425 6396
SMS: PHILIPS to 56677 Mon.~Fri. 9:00am-5:30pm
Indonesia PT. CORMIC SERVISINDO
PERKASA
+62-21-4080-9086 (Customer
Hotline)
+62-8888-01-9086 (Customer
Hotline)
Mon.~Thu. 08:30-12:00;
13:00-17:30
Fri. 08:30-11:30; 13:00-17:30
Korea Alphascan Displays, Inc 1661-5003 Mon.~Fri. 9:00am-5:30pm
Sat. 9:00am-1:00pm
Malaysia R-Logic Sdn Bhd +603 5102 3336 Mon.~Fri. 8:15am-5:00pm
Sat. 8:30am-12:30am
Pakistan TVONICS Pakistan +92-213-6030100 Sun.~Thu. 10:00am-6:00pm
Singapore
Philips Singapore Pte Ltd
(Philips Consumer Care
Center)
(65) 6882 3966 Mon.~Fri. 9:00am-6:00pm
Sat. 9:00am-1:00pm
Taiwan FETEC.CO 0800-231-099 Mon.~Fri. 09:00 - 18:00
Thailand Axis Computer System Co.,
Ltd. (662) 934-5498 Mon.~Fri. 8:30am~05:30pm
South Africa Computer Repair Technologies 011 262 3586 Mon.~Fri. 8:00am~05:00pm
Israel Eastronics LTD 1-800-567000 Sun.~Thu. 08:00-18:00
Vietnam
FPT Service Informatic
Company Ltd. - Ho Chi Minh
City Branch
+84 8 38248007 Ho Chi Minh
City
+84 5113.562666 Danang City
+84 5113.562666 Can tho
Province
Mon.~Fri. 8:00-12:00, 13:30-
17:30,Sat. 8:00-12:00
Philippines EA Global Supply Chain
Solutions ,Inc. (02) 655-7777; 6359456 Mon.~Fri. 8:30am~5:30pm
Armenia
Azerbaijan
Georgia
Kyrgyzstan
Tajikistan
Firebird service centre +97 14 8837911 Sun.~Thu. 09:00 - 18:00
Uzbekistan Soniko Plus Private Enterprise
Ltd +99871 2784650 Mon.~Fri. 09:00 - 18:00
Turkmenistan Technostar Service Centre +(99312) 460733, 460957 Mon.~Fri. 09:00 - 18:00
Japan フィリップスモニター
・サポートセンター 0120-060-530 Mon.~Fri. 10:00 - 17:00
46
9. Troubleshooting & FAQ
s
9. Troubleshooting & FAQs
9.1 Troubleshooting
This page deals with problems that can be
corrected by a user. If the problem still persists
after you have tried these solutions, contact
Philips customer service representative.
Common Problems
No Picture (Power LED not lit)
Make sure the power cord is plugged into
the power outlet and into the back of the
monitor.
First, ensure that the power button on the
front of the monitor is in the OFF position,
then press it to the ON position.
No Picture (Power LED is White)
Make sure the computer is turned on.
Make sure the signal cable is properly
connected to your computer.
Make sure the monitor cable has no bent
pins on the connect side. If yes, repair or
replace the cable.
The Energy Saving feature may be activated
Screen says
Attention
Check cable connection
Make sure the monitor cable is properly
connected to your computer. (Also refer to
the Quick Start Guide).
Check to see if the monitor cable has bent
pins.
Make sure the computer is turned on.
AUTO button doesn't function
The auto function is applicable only in
VGA-Analog mode. If the result is not
satisfactory, you can do manual adjustments
via the OSD menu.
Note
The Auto Function is not applicable in DVI-
Digital mode as it is not necessary.
Visible signs of smoke or sparks
Do not perform any troubleshooting steps
Disconnect the monitor from mains power
source immediately for safety
Contact with Philips customer service
representative immediately.
Imaging Problems
Image is not centered
Adjust the image position using the “Auto”
function in OSD Main Controls.
Adjust the image position using the Phase/
Clock of Setup in OSD Main Controls. It is
valid only in VGA mode.
Image vibrates on the screen
Check that the signal cable is properly
securely connected to the graphics board
or PC.
9HUWLFDOÁLFNHUDSSHDUV
Adjust the image using the “Auto” function
in OSD Main Controls.
Eliminate the vertical bars using the Phase/
Clock of Setup in OSD Main Controls. It is
valid only in VGA mode.
+RUL]RQWDOÁLFNHUDSSHDUV
Adjust the image using the “Auto” function
in OSD Main Controls.
47
9. Troubleshooting & FAQ
s
Eliminate the vertical bars using the Phase/
Clock of Setup in OSD Main Controls. It is
valid only in VGA mode.
Image appears blurred, indistinct or too dark
Adjust the contrast and brightness on
On-Screen Display.
An "after-image", "burn-in" or "ghost image"
remains after the power has been turned off.
Uninterrupted display of still or static
images over an extended period may cause
"burn in", also known as "after-imaging "
or "ghost imaging", on your screen. "Burn-
in", "after-imaging", or "ghost imaging" is a
well-known phenomenon in LCD panel
technology. In most cases, the "burned in"
or "after-imaging" or "ghost imaging" will
disappear gradually over a period of time
after the power has been switched off.
Always activate a moving screen saver
program when you leave your monitor
unattended.
Always activate a periodic screen refresh
application if your LCD monitor will display
unchanging static content.
Failure to activate a screen saver, or a
periodic screen refresh application may
result in severe “burn-in” or “after-image”
or “ghost image” symptoms that will not
disappear and cannot be repaired. The
damage mentioned above is not covered
under your warranty.
Image appears distorted. Text is fuzzy or
blurred.
Set the PC’s display resolution to the same
mode as monitor’s recommended screen
native resolution.
Green, red, blue, dark, and white dots appears
on the screen
The remaining dots are normal
characteristic of the liquid crystal used in
today’s technology, Please refer the pixel
policy for more detail.
The "power on" light is too strong and is
disturbing
You can adjust “power on” light using the
power LED Setup in OSD main Controls.
For further assistance, refer to the Consumer
Information Centers list and contact Philips
customer service representative.
9.2 SmartControl Premium FAQs
Q1. I change the monitor on a PC to a
different one and the SmartControl
Premium becomes un-usable, what do
I do?
Ans.: Restart your PC and see if
SmartControl Premium can work.
Otherwise, you will need to remove
and re-install SmartControl Premium to
ensure proper driver is installed.
Q2. The SmartControl Premium functions
worked well before, but it does not
work anymore, what can I do?
Ans.: If the following actions were executed,
the monitor driver may need to be re-
installed.
Changed video graphic adapter to another
one
Updated video driver
Activities on OS, such as service pack or
patch
Run Windows Update and updated
monitor and/or video driver
Windows was booted with the monitor
power off or disconnected.
To find out, please right click My Computer
and click on Properties->Hardware->
Device Manager.
If you see “Plug and Play Monitor” shows
under Monitor, then you need to re-install.
Simply remove SmartControl Premium and
re-install it.
48
9. Troubleshooting & FAQ
s
Q3. After installing SmartControl Premium,
when clicking on SmartControl
Premium tab, nothing shows up after a
while or a failure message shows, what
happened?
Ans.: It might be your graphic adaptor is not
compatible with the SmartControl
Premium. If your graphic adaptor is one
of the above mentioned brands, try to
download the most updated graphic
adaptor driver from corresponding
companies’ web site. Install the driver.
Remove SmartControl Premium, and
re-install it once more.
If it is still not working, we are sorry that
the graphic adaptor is not supported.
Please visit Philips website and check
if an updated SmartControl Premium
driver is available.
Q4. When I click on Product Information,
only partial information is shown, what
happened?
Ans.: It might be your graphic card adaptor
driver is not the most updated
version which fully supporting DDC/
CI interface. Please try to download
the most updated graphic adaptor
driver from corresponding companies’
web site. Install the driver. Remove
SmartControl Premium and re-install it
once more.
Attention
Theft Deterrence is Enabled
Q5. I forgot my PIN for Theft Deterrence
Function. How can I do?
Ans.:Philips Service center has a right to
DVNIRUOHJLWLPDWHLGHQWLÀFDWLRQDQG
authorization, in order to establish
ownership of the monitor.
9.3 General FAQs
Q1: When I install my monitor what should
I do if the screen shows 'Cannot
display this video mode'?
Ans.: Recommended resolution for this
monitor: 1920 x 1200 @ 60 Hz.
Unplug all cables, then connect your PC to
the monitor that you used previously.
In the Windows Start Menu, select Settings/
Control Panel. In the Control Panel
Window, select the Display icon. Inside the
Display Control Panel, select the 'Settings'
tab. Under the setting tab, in box labelled
'desktop area', move the sidebar to 1920 x
1200 pixels.
Open 'Advanced Properties' and set the
Refresh Rate to 60 Hz, then click OK.
Restart your computer and repeat step 2
and 3 to verify that your PC is set at 1920
x 1200 @ 60 Hz.
Shut down your computer, disconnect your
old monitor and reconnect your Philips
LCD monitor.
Turn on your monitor and then turn on
your PC.
Q2: What is the recommended refresh
rate for LCD monitor?
Ans.: Recommended refresh rate in LCD
monitors is 60 Hz, In case of any
disturbance on screen, you can set it
up to 75 Hz to see if that removes the
disturbance.
4 :KDWDUHWKHLQIDQGLFPÀOHVRQWKH
CD-ROM? How do I install the drivers
(.inf and .icm)?
Ans.:7KHVHDUHWKHGULYHUÀOHVIRU\RXU
monitor. Follow the instructions in your
user manual to install the drivers. Your
computer may ask you for monitor
GULYHUVLQIDQGLFPÀOHVRUDGULYHU
GLVNZKHQ\RXÀUVWLQVWDOO\RXUPRQLWRU
Follow the instructions to insert the
companion CD-ROM included in this
49
9. Troubleshooting & FAQ
s
package. Monitor drivers (.inf and .icm
ÀOHVZLOOEHLQVWDOOHGDXWRPDWLFDOO\
Q4: How do I adjust the resolution?
Ans.: Your video card/graphic driver and
monitor together determine the
available resolutions. You can select the
desired resolution under Windows®
Control Panel with the "Display
properties".
Q5: What if I get lost when I am making
monitor adjustments via OSD?
Ans.: Simply press the OK button, then select
'Reset' to recall all of the original factory
settings.
Q6: Is the LCD screen resistant to
scratches?
Ans.: In general it is recommended that
the panel surface is not subjected to
excessive shocks and is protected from
sharp or blunt objects. When handling
the monitor, make sure that there is
no pressure or force applied to the
panel surface side. This may affect your
warranty conditions.
Q7: How should I clean the LCD surface?
Ans.: For normal cleaning, use a clean, soft
cloth. For extensive cleaning, please use
isopropyl alcohol. Do not use other
solvents such as ethyl alcohol, ethanol,
acetone, hexane, etc.
Q8: Can I change the color setting of my
monitor?
$QV Yes, you can change your color setting
through OSD control as the following
procedures,
Press "OK" to show the OSD (On Screen
Display) menu
Press "Down Arrow" to select the option
"Color" then press "OK" to enter color
setting, there are three settings as below.
Color Temperature: The six settings are
5000K, 6500K, 7500K, 8200K, 9300K
and 11500K. With settings in the 5000K
range the panel appears "warm, with a
red-white color tone", while a 11500K
temperature yields "cool, bluewhite
toning".
sRGB: This is a standard setting for
ensuring correct exchange of colors
between different device (e.g. digital
cameras, monitors, printers, scanners,
etc).
8VHU'HÀQH7KHXVHUFDQFKRRVHKLV
her preference color setting by adjusting
red, green blue color.
Note
A measurement of the color of light radiated
by an object while it is being heated. This
measurement is expressed in terms of
absolute scale, (degrees Kelvin). Lower Kevin
temperatures such as 2004K are red; higher
temperatures such as 9300K are blue. Neutral
temperature is white, at 6504K.
Q9: Can I connect my LCD monitor to any
PC, workstation or Mac?
$QV Yes. All Philips LCD monitors are fully
compatible with standard PCs, Macs
and workstations. You may need a cable
adapter to connect the monitor to
your Mac system. Please contact your
Philips sales representative for more
information.
Q10: Are Philips LCD monitors Plug-and-
Play?
$QV Yes, the monitors are Plug-and-Play
compatible with Windows 8/7/Vista/XP/
NT, Mac OSX, Linux
Q11: What is Image Sticking, or Image Burn-
in, or After Image, or Ghost Image in
LCD panels?
Ans.: Uninterrupted display of still or static
images over an extended period
50
9. Troubleshooting & FAQ
s
may cause "burn in", also known as
"after-imaging" or "ghost imaging", on
your screen. "Burn-in", "after-imaging",
or "ghost imaging" is a well-known
phenomenon in LCD panel technology.
In most cases, the "burned in" or
"atter-imaging" or "ghost imaging" will
disappear gradually over a period of
time after the power has been switched
off.
Always activate a moving screen saver
program when you leave your monitor
unattended.
Always activate a periodic screen
refresh application if your LCD monitor
will display unchanging static content.
Warning
Failure to activate a screen saver, or a periodic
screen refresh application may result in severe
“burn-in” or “after-image” or “ghost image”
symptoms that will not disappear and cannot be
repaired. The damage mentioned above is not
covered under your warranty.
Q12: Why is my Display not showing
sharp text, and is displaying jagged
characters?
Ans.: Your LCD monitor works best at its
native resolution of 1920 x 1200 @
60 Hz. For best display, please use this
resolution.
9.4 Medical FAQ
Q1: Can I use color image in Clinical D-image
mode?
$QV Clinical D-image mode is DICOM part-
14 calibrated for Grayscale performance
only.
Q2: Can I clean the monitor and will it affect
its Antimicrobial housing ?
$QV Yes, you can clean with normal monitor
cleaner or plain water. It will not affect
its Antimicrobial housing, as it is a
permanent part of the body (not a
coating)
Q3: Can I use alcohol to clean the monitor?
$QV Alcohol should not be used to clean the
monitor as it has potential to damage
or deform the plastics and LCD screen
and its relevant coatings.
Q4: Can I use the monitor in a patient
vicinity environment?
$QV Yes, this monitor can be used in the
patient vicinity environments for it
complies with MOPP of ANSI/AAMI
ES60601-1.
© 2013 Koninklijke Philips N.V. All rights reserved.
Philips and the Philips Shield Emblem are registered trademarks of
Koninklijke Philips N.V. and are used under license from
Koninklijke Philips N.V.
6SHFLÀFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH
Version: M4C240P4E1T