Philips CoreLine Batten User Manual
Displayed below is the user manual for CoreLine Batten by Philips which is a product in the Ceiling Lighting category. This manual has pages.
Related Manuals
BN126C EL
.Max
0 °C
Min.
35 °C
IK04
50 Hz
60 Hz
220 V
240 V
BN126C LED52S/840 PSU ELB3 TW1 L1500
kg
System light
output (Lm)
5200
BN126C LED41S/840 PSU ELB3 TW1 L1200 4100
System light
output
Emergency
mode (Lm)
GLOW
WIRE
850 °C
CoreLine
Batten
Printed in Hungary
Data subject to change without notice
Keep for future reference: www.philips.com/lighting
1/6
444316022561 - 01
© 03 / 2020 Signify Holding All rights reserved
A B C D H L W
BN126C L1200 960 40 1073 600 65 1135 65
BN126C L1500 972 40 1073 600 65 1450 65
Type
Dimension (mm)
1x 1x
4x
4x
1,8
2,1
A/B:
Fixed Mounting Holes
C:
Suspension Mounting Holes
D:
BESA Holes
D
A
C
36
4-5
36
B
420
420
IP40
IP20
L 65
Ta
°C
25
P1
indoor LIFE
L70B50
50K hrs
IP
IP
20
40
Unit: mm
O 6mm
18
3x
T20
T10
2b
2/6
3
UN-SWITCHED / NON-MAINTAINED LINE
SWITCHED / MAINTAINED LINE
or
1x 2x
2x
2x
2x
2x
O 5,5
BESA
4x
SW N
Mounted with BESA
Suspend Mounted
12a
O 5,5
O 5,5
Wiring from end hole
SWN - Switched neutral
45
30 8
SWL - Switched line
L- Unswitched line
L
SWL
SWN
SWN
L
2c
N - Unswitched neutral
Optional
2x 2x
2x
2x
P1
0,5 Nm
P1
0,5 Nm
P1
0,5 Nm
0,5 Nm
O6-12mm
q0,75-2,5mm²
Surface mounted - optional
12
The luminaire shall be installed by a qualied electrican and
wired in accordance with the latest IEE electrical regulations
or the national requirements.
A T T E N T I O N
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE
DEVICES
Max.number of connected
luminaire 10x
T10
3/6
9
Wiring from back hole
L
N
SWL
SWN
L
N
SWL
SWN
1x
2x
3x
L
N
SWL
SWN
L
N
SWL
SWN
The end face of the first
luminaire and the last luminaire
1x
2x 3x
1x 2x 3x
P1
0,5 Nm
4
5 6
78
Vertical
10
4/6
A T T E N T I O N
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE
DEVICES
Reflector:A2 It can be fixed either on
one side or on both sides
Reflector A2 Reflector A1
or
Item Installation mode 12NC Description
1 suspension 911401776802 BN126Z SC
2 surface or suspension 911401776822 BN126Z REF A1 L1200
3 surface or suspension 911401776832 BN126Z REF A1 L1500
4 surface or suspension 911401776862 BN126Z REF A2 L1200
5 surface or suspension 911401776872 BN126Z REF A2 L1500
1m
4x
Reflector A1 Suspension Wire
Status LED indication shown on page 6
Do not touch electronic components!
Electronic components maybe under high voltage.
Caution, risk of electric shock
P1
0,5 Nm
SERVICE
The light source of this luminaire is not
replaceable; when the light source reaches
it's end of life the whole luminaire shall be
replaced.
LED driver is not serviceable. When it
reaches it's end of life the whole luminaire
shall be replaced.
Luminaire must not be used or stored in
corrosive environment where hazardous
materials such as sulphur, chlorine,
phthalates, etc, are present.
Reflector A2
5/6
10
A T T E N T I O N
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE
DEVICES
The batteries have a life time expectancy of 4 years.
Do not touch electronic components!
Electronic components may be under high voltage.
Ipeak [A]
Tref [μs]
Drivers / MCB 16A type B [max.]
Drivers / MCB 10A type B [max.]
Drivers / MCB 16A type C [max.]
Drivers / MCB 10A type C [max.]
5,16
47
5,56
47
60
37
102
62
45
28
76
46
Max. Nr of products
LED41S LED52S
T20
Light intensity distribution curves
Emergency mode
x2
6/6
Maintenance instructions
To assure the lighting quality of this unique LED lighting concept there are only a few
instructions regarding the maintenance of this LED luminaire:
* Do not stare into LED light beam.
* The luminaire shall be installed by a qualified electrician and wired in accordance with
the latest IEE electrical regulations or the national requirements.
* Above average concentracion of sulfur effects the useful lifetime of the product.
E.g: Light color changes from white to blue. Typically in chicken & pig farms.
Functional Notice for Emergency Lighting
Automatic emergency time selection
After installation and power up the driver will detect the battery and start the automatic detection process.
• During automatic detection, the indicator LED will light up with short green flashes.
• Between minimum 6 and maximum 30 seconds the TrustSight driver will set the battery type (number of cells)
and will set the emergency output power accordingly.
After that, the system is defined and fully operational. The
battery type definition has influence on the performance
during the self-test and on the battery charge method. When the
automatic battery detection process is disrupted,
e.g. by switching off the permanent mains, the detection process is
stopped and the TrustSight emergency driver
will go into emergency mode with the lowest output power. At a next
power up, the automatic detection process
will start again.
Periodic testing
Periodic tests of emergency lighting luminaires must b
e performed according to EN50172 clause 7.2.3 and 7.2.4.
Switch on in the emergency mode each month by simulation of a failure of the supply to the normal lighting for
a period sufficient to ensure that each lamp is illuminated. Twice per year, each lumina
ire shall be tested for its
full rated duration (at least 3hrs).
For more information please consult the TrustSight Gen 3 Design in guide. The latest version is available online.