Samsung AM056FN4DEH User Manual
Displayed below is the user manual for AM056FN4DEH by Samsung which is a product in the Split-System Air Conditioners category. This manual has pages.
Related Manuals
Air Conditioner
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
Cassette Type Series
1 Way cassette : AM✴✴✴FN1DEH✴
AM✴✴✴HN1DEH✴
AM✴✴✴JN1DEH✴
2 Way cassette : AM✴✴✴FN2DEH✴
4 Way cassette : AM✴✴✴FN4DEH✴
AM✴✴✴KN4FEH✴
02_ features
features of your new
air conditioner
• Cool Summer Offer
On those hot sweltering summer days and long restless nights, there is no better escape
from the heat than the cool comforts of home. Your new air conditioner brings an end to
exhausting hot summer days and lets you rest. This summer, beat the heat with your own
air conditioner.
• Cost Efficient System
Your new air conditioner not only provides maximum cooling power in the summer, but can
also be an efficient heating method in the winter with the advanced “Heat pump” system.
This technology is up to 300 % more efficient than electrical heating, so you can further
reduce its running cost. Now, meet year-round needs with one air conditioner.
• A Look for Everywhere
The elegant and harmonious design gives priority to the esthetics of your space and
complements any of your existing interior décor. With its soft color and rounded-edge shape,
the new air conditioner adds class to any room. Enjoy what your air conditioner offers both
functionally and esthetically.
• Compact and easy-to-use Cassette type
Designed to be installed into most types of suspended ceiling, the cassette type air
conditioner is ideal for business and commercial accommodations. Fresh cool/warm air
can be provided through the controllable 1, 2 or 4 sides of the unit. All functions of the air
conditioner will be controlled easily via a remote control.
safety information _03
ENGLISH
safety information
To prevent electric shock, disconnect the power before
servicing, cleaning, and installing the unit.
SAFETY INFORMATION
Before using your new air conditioner, please read this
manual thoroughly to ensure that you know how to safely
and efficiently operate the extensive features and functions
of your new appliance.
Because the following operating instructions cover various
models, the characteristics of your air conditioner may differ
slightly from those described in this manual. If you have
questions, call your nearest contact center or find help and
information online at www.samsung.com.
What the icons and signs in this user manual
mean:
WARNING Risk of death or serious personal injury.
CAUTION
Potential risk of personal injury or material
damage.
CAUTION
To reduce the risk of fire, explosion,
electric shock, or personal injury when
using your air conditioner, follow these
basic safety instructions:
04_ safety information
safety information
Do NOT attempt.
Do NOT disassemble.
Do NOT touch.
Follow directions carefully.
Unplug the power plug from the wall socket.
Make sure the machine is grounded to
prevent electric shock.
Call the contact center for help.
Recommended instructions or useful
information for use.
These warning signs are here to prevent injury to
you and others.
Please follow them carefully.
After reading this section, keep it in a safe place
for future reference.
WARNING
SEVERE WARNING SIGNS
Do not place the air conditioner near hazardous
substances or equipment that releases free
flames to avoid fire, explosions or injuries.
• Potential risk of fire hazard or explosion.
Do not block or place items in front of the air
conditioner. Do not step, hang onto, or place
heavy items on the air conditioner.
• Potential risk of personal injury.
safety information _05
ENGLISH
Do not install the outdoor unit at an unstable
place or elevated surface where there is
potential risk of falling.
• If the outdoor unit falls, it may cause personal
injury or loss or property.
Any changes or modifications performed not
following by the installation manual, failure or
damage may occur on the condition. In this
case, user will be responsible for all the repair
expenses.
If any gas or impurities other than R-410A
refrigerant come into the refrigerant pipe,
serious problem may occur and it may cause
injury.
Do not spray flammable gases such as
insecticide near the air conditioner.
• Potential risk of electric shock, fire or unit
malfunction.
Do not insert anything such as fingers or
branches into the air conditioner vents.
• Keep children away from the air conditioner.
Potential risk of personal injury.
Do not cut the power plug and connect to a
different power cable.
Never attempt to lengthen the power cable.
• Potential risk of fire or electric shock.
Do not yank the power cable and touch the
power plug with hands.
• Potential risk of fire or electric shock.
06_ safety information
safety information
WARNING
SEVERE WARNING SIGNS
Never use a damaged power plug, power cable,
or loosened power receptacle.
• Potential risk of fire or electric shock.
The electric work must be done by qualified
service technician in accordance with the
national wiring regulations with rated cables.
• If the capacity of the power cable is insufficient
or electric work have not done properly, electric
shock or fire may occur.
You should connect the power cable into the
power cable terminal and fasten it with a clamp.
Do not connect the air conditioner with heating
apparatus or attempt to disassemble, remodel
or repair it by yourself.
• Potential risk of malfunction, electric shock or fire.
If repairs are needed, consult the contact center.
Consult the place of purchase or a contact
center to disassemble or reinstall the air
conditioner.
• Potential risk of unit malfunction, water leakage,
electric shock, or fire.
safety information _07
ENGLISH
Consult the place of purchase or contact center
to install the air conditioner.
• Improper installation carries a risk of unit
malfunction, water leakage, electric shock or fire.
• If installing in specialty areas, such as a factory
complex or saline coastal area, consult the
place of purchase or contact center for specific
installation details.
Install the air conditioner with the support
bracket securely fastened to use for an
extended period of time.
• If the air conditioner falls, it may cause personal
injury or loss of property.
If the indoor unit gets wet, turn the power off
immediately and call your nearest contact
center.
• Potential risk of fire or electric shock.
Install an exclusive circuit breaker and short-
circuit breaker for the air conditioner.
• Potential risk of electric shock or fire.
If the power cable is damaged, the manufacturer
or a qualified service technician must replace it.
Always make sure that the power supply is
compliant with current safety standards. Always
install the air conditioner in compliance with
current local safety standards.
Verify that the voltage and frequency of the
power supply comply with the specifications and
that the installed power is sufficient to ensure
the operation of any other domestic appliance
connected to the same electric lines.
08_ safety information
safety information
WARNING
SEVERE WARNING SIGNS
The air conditioner must be installed in
accordance with national wiring regulations and
safety regulations wherever applicable.
Install the supplied cables firmly. Fix them
securely so that external force is not exerted to
the terminal block.
• If the connection is loose, heat may generate and
cause electric shock or fire.
Use a rated circuit breaker only.
• Never use steel wires or copper wires as a circuit
breaker. It may cause fire or unit malfunction.
Use an exclusive power source for the air
conditioner.
• Potential risk of electric shock or fire.
Do not put undue stress or place heavy object
on the power cable.
Do not bend the power cable excessively.
• Potential risk of fire or electric shock.
Always verify that electric connections (cable
entry, section of leads, protections...) are
compliant with the electric specifications and
with the instructions provided in the wiring
scheme.
Always verify that all connections comply with
the standards applicable to the installation of air
conditioners.
safety information _09
ENGLISH
Use a receptacle that has a ground terminal.
The receptacle must be used exclusively for the
air conditioner.
• Improper electrical grounding may cause electric
shock or fire.
Be sure to ground the unit. Do not connect the
ground wire to gas or water pipes, lighting rods,
or telephone grounding lines.
• If the unit is not properly grounded, electric shock
may result.
Always verify that a suitable grounding
connection is available.
Disconnect the air conditioner from power
supply before it is repaired or disassembled.
CAUTION CAUTION SIGNS
Connect the refrigerant tubes first then the
electrical lines, when installing the unit.
Always disassemble the electric lines before the
refrigerant tubes.
Verify that the air conditioner is connected
to the power supply in accordance with the
instructions provided in the wiring diagram
included in the manual.
The manufacturer shall not be responsible for
damage originating from unauthorized changes
or the improper connection of electric and
hydraulic lines.
10_ safety information
safety information
CAUTION CAUTION SIGNS
Failure to comply with these instructions or to
comply with the requirements set forth in the
“Operating limits” table, included in the manual,
and shall immediately invalidate the warranty.
Ensure no water gets into the air conditioner.
• Potential risk or electric shock.
Turn off the air conditioner using the provided
remote control or control accessory (if
provided). Do not unplug to turn off the unit
(unless there is an immediate danger).
Do not open the front grille during operation.
• Potential risk of electric shock or unit malfunction.
Cool air should not flow directly towards people,
pets, and plants.
• It is harmful to your health, pets, and plants.
Do not run the air conditioner for an extended
period of time in a room with the door closed or
with babies, elderly or disabled people.
• Open the door or windows to ventilate your room
at least once an hour to prevent oxygen shortage.
Do not drink drain water coming out of the air
conditioner.
• Potential risk of health hazard.
Do not expose the dust filter to direct sunlight
while drying.
• Strong direct sunlight may deform the dust filter.
safety information _11
ENGLISH
Do not allow children to climb on the air
conditioner.
Use only rated accessories and install the air
conditioner with rated equipments.
• If you do not use the rated accessories, the air
conditioner may drop from its place, water may
leak or electric shock or fire may occur.
Do not use the air conditioner as a cooling
precision instrument for food, pets, plants,
cosmetics or machinery.
Do not give excessive shock to the air
conditioner.
• Potential risk of fire or unit malfunction.
Do not spray water directly on the air
conditioner or use benzene, thinner or alcohol
to clean the surface of the unit.
• Potential risk of electric shock or fire.
• Potential risk of damage to the air conditioner.
Do not place any objects, especially containers
with liquid.
Do not touch the pipe connected to the air
conditioner.
This appliance should be installed according to
the provided installation manual.
Install the shortest possible length of pipe.
• If the length of pipe gets unnecessarily long, the
life of air conditioner can be shorten and become
inefficient.
12_ safety information
safety information
CAUTION CAUTION SIGNS
Install the power cable and communication
cable of the indoor and outdoor unit at least 1m
away from the electric appliance.
Install the indoor unit away from lighting
apparatus using the ballast.
• If you use the wireless remote control, reception
error may occur due to the ballast of the lighting
apparatus.
For maximum safety, installers should always
carefully read the following warnings.
Do not install the air conditioner in following
places.
• Place where there is mineral oil or arsenic acid.
• Resin parts flame and the accessories may drop
or water may leak. The capacity of the heat
exchanger may reduce or the air conditioner may
be out of order.
• The place where corrosive gas such as sulfurous
acid gas generates from the vent pipe or air outlet.
• The copper pipe or connection pipe may corrode
and refrigerant may leak.
• The place where there is a machine that
generates electromagnetic waves.
The air conditioner may not operate normally due
to control system.
• The place where there is a danger of existing
combustible gas, carbon fiber of flammable dust.
safety information _13
ENGLISH
• The place where thinner or gasoline is handled
Gas may leak and it may cause fire.
If the air conditioner is installed in a small
room, measures must be taken to prevent the
refrigerant concentration in the room from
exceeding the safety limit in the event of
refrigerant leakage.
Consult a dealer regarding the appropriate
measures to prevent the allowable
concentration from being exceeded.
• If the refrigerant leaks, and cause the
concentration limit to be exceeded, hazards due
to lack of oxygen in the room may result.
Install the air conditioner away from direct
exposure to sunlight, heating apparatus, and
humid places.
• Hang curtains on windows to boost cooling
efficiency and to avoid the risk of electric shock.
The air conditioner is composed of moving
parts. Keep children away from the unit to avoid
physical injury.
Check for damage on delivery. If damaged, do
not install the air conditioner and call the place
of purchase immediately.
Insert the dust filter before operating the air
conditioner.
• If there is no dust filter inside the air conditioner,
accumulated dust may shorten the life of the air
conditioner and cause electricity waste.
14_ safety information
safety information
CAUTION CAUTION SIGNS
Keep indoor temperatures stable and not
extremely cold, especially where there are
children, elderly or disabled people.
Clean the dust filter every 2 weeks. Clean the
filter more frequently if the air conditioner is
operated in dusty areas.
The packaging material and used batteries
of the remote controller (optional) must be
disposed of in accordance with the national
standards.
The refrigerant used in the air conditioner must
be treated as chemical waste. Dispose the
refrigerant following national standards.
Have a qualified service technician install the air
conditioner and perform a trial operation.
Firmly connect the drain hose to the air
conditioner for proper water drainage.
Install the outdoor unit where operating noise
and vibration will not disturb your neighbor and
in a well-ventilated area with no obstacle.
• Potential risk of malfunction.
• Operating noise may disturb your neighbor.
safety information _15
ENGLISH
Make sure that children take precautions
against access to the air conditioner and they
do not play with the unit.
When using a wireless remote control, the
distance should not be more than 7 meters from
the air conditioner.
If the remote control is not used for a long
period of time, remove the batteries to prevent
leakage of electrolyte.
When cleaning the outdoor unit, touch the heat
exchanger radiator fins with extreme care.
• Wearing thick gloves can protect your hands.
Make sure that the condensed water dripping
from the drain hose runs out properly and safely.
Store the operation and installation manual in a
safe location and remember to hand it over to
the new owner if the air conditioner is sold or
transferred.
All the materials used for the manufacture and
packaging of the air conditioner are recyclable.
After completing the installation, always carry
out a functional test and provide the instructions
on how to operate the air conditioner to the
user.
16_ safety information
safety information
CAUTION CAUTION SIGNS
The appliance is not intended for use by young
children or infirm persons without supervision:
Young children should be supervised to ensure
that they do not play with the appliance.
Clean the air conditioner after the inner fan
stops operating.
• Potential risk of injury or electric shock.
Inspect the condition, electric connections,
pipes and external case of the air conditioner
regularly by a qualified service technician.
Do not open doors and windows in the room
being cooled during operation unless necessary.
Do not block the air conditioner vents. If objects
block the air flow, it may cause unit malfunction
or poor performance.
Make sure there are no obstacles under the
indoor unit.
• Potential risk of fire or loss of property.
safety information _17
ENGLISH
Make sure that there are no obstacles or covers
that block the air conditioner.
Allow sufficient space for air circulation.
• Insufficient ventilation may result in poor
performance.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety. Children should be
supervised to ensure that they do not play with
the appliance.
For use in Europe : This appliance can be used
by children aged from 8 years and above and
persons with reduced physical, sensory or
mental capabilities or lack of experience and
knowledge if they have been given supervision
or instruction concerning use of the appliance
in a safe way and understand the hazards
involved. Children shall not play with the
appliance. Cleaning and user maintenance shall
not be made by children without supervision.
18_ safety information
safety information
CAUTION CAUTION SIGNS
Make sure the voltage and frequency of the
electric system are compatible with the air
conditioner.
If a power outage occurs while the air
conditioner is working, turn off the power source
immediately.
Max current is measured according to IEC
standard for safety and current is measured
according to ISO standard for energy efficiency.
The unit must be plugged into an independent
circuit if applicable or connect the power cable
to the auxiliary circuit breaker. An all pole
disconnection from the power supply must be
incorporated in the fixed wiring with a contact
opening of >3mm.
After connecting the power cable between
the indoor/outdoor unit, attach the cover of
component box securely and make sure it is not
loose.
safety information _19
ENGLISH
Power supply cords of parts of appliances
for outdoor use shall not be lighter than
polychloroprene sheathed flexible cord.
(Code designation IEC:60245 IEC 57 /
CENELEC:H05RN-F or IEC:60245 IEC 66 /
CENELEC: H07RN-F)
The unbalanced power must be maintained
within 10 % of supply rating among whole
indoor units.
If the power is unbalanced greatly, it may
shorten the life of the condenser.
If the unbalanced power is exceeded over 10%
of supply rating, the indoor unit is protected,
stopped and the error mode indicates.
To protect the product from water and possible
shock, you should keep the power cable and
the connection cord of the indoor and outdoor
units in the protection tube.
Connect the power cable to the auxiliary circuit
breaker.
You must keep the cable in a protection tube.
Keep distances of 50mm or more between
power cable and communication cable.
Maximum length of power cable is decided
within 10 % of power drop. If it exceeds,
you must consider another power supplying
method.
20_ safety information
safety information
CAUTION CAUTION SIGNS
The circuit breaker (MCCB, ELB) should be
considered more capacity, if many indoor units
are connected from one breaker.
Use solderless ring terminal to connect the
power cable to the power terminal block.
Use an appropriate screwdriver for tightening
the terminal screws.
Over-tightening the terminal screws may break
them.
The air conditioner should be used only for the
applications for which it has been designed: the
indoor unit is not suitable to be installed in areas
used for laundry.
safety information _21
ENGLISH
Our units must be installed in compliance with
the spaces indicated in the installation manual
to ensure either accessibility from both sides
or ability to perform routine maintenance
and repairs. The units’ components must be
accessible and that can be disassembled
in conditions of complete safety either for
people or things. For this reason, where it is
not observed as indicated into the Installation
Manual, the cost necessary to reach and
repair the unit (in safety, as required by current
regulations in force) with slings, trucks,
scaffolding or any other means of elevation
won’t be considered in-warranty and charged to
end user.
22_ safety information
safety information
CAUTION CAUTION SIGNS
Ensure the off-on and protection switches are
properly installed.
Do not use the air conditioner if damaged. If
problems occur, immediately stop operation and
disconnect the plug from the power supply.
If the air conditioner will not be used for an
extended period of time (for example, over
several months), unplug the power from the
wall.
Call the place of purchase or a contact center if
repairs are needed.
• Potential risk of fire or electric shock if
disassembly or repairs are attempted by a non-
qualified service technician.
If you smell burning plastic, hear strange
sounds, or see smoke coming from the unit,
unplug the air conditioner immediately and call
a contact center.
• Potential risk of fire or electric shock.
contents _23
ENGLISH
contents
VIEWING YOUR AIR CONDITIONER
24
24 Slim 1 way cassette
25 2 way cassette
25 4 way cassette
USING YOUR AIR CONDITIONER
26
26 Tips on using your air conditioner
CLEANING AND MAINTAINING
THE AIR CONDITIONER
28
28 Cleaning the exterior
28 Cleaning the grille
28 Slim 1 way cassette
30 2 way cassette
31 4 way cassette
32 Cleaning the filter
32 Slim 1 way cassette
36 2 way cassette
37 4 way cassette
38 Maintaining your air conditioner
38 Periodical checks
39 Internal protections via the unit control
system
APPENDIX
40
40 Troubleshooting
43 Operation ranges
43 Model specification
(Weight and dimension)
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger,
headset, USB cable) should not be disposed of with other household waste at the end of their working life. To prevent
possible harm to the environment or human health from uncontrolled waste disposal, please separate these items from other
types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for
details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and
its electronic accessories should not be mixed with other commercial wastes for disposal.
INSTALLING YOUR
AIR CONDITIONER
44
44 Installation part
For information on Samsung’s environmental commitments and product specific regulatory obligations e.g. REACH visit:
samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html
24_ viewing your air conditioner
viewing your air conditioner
Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air
conditioner and stay cool or warm with optimal efficiency.
Please read the user manual to get started and to make the best use of the air conditioner.
SLIM 1 WAY CASSETTE
Main parts
X PC1NUSMAN
X PC1MWSKAN/PC1NWSMAN/PC1BWSMAN
X PC1NUPMAN
When operating an indoor unit (including Fan mode), SPi will not operate automatically.
So, press the [Super Fan] button on the wireless remote controller to operate SPi.
Air flow blade
Air intake
Panel
Air filter (under the grille)
Display
Remote control sensor
Timer indicator
Filter reset indicator
PC1NUSMAN/PC1MWSKAN/
PC1NWSMAN/PC1BWSMAN
- Model not equipped with S-Plasma ion:
Fan indicator
- Model equipped with S-Plasma ion:
Super Fan indicator
PC1NUPMAN: Super Fan Indicator
Heating and cooling model
Operation(Blue) / Defrost(Yellow)
Cooling only model
Operation indicator
Air flow blade
Air intake
Panel
Air filter (under the grille)
viewing your air conditioner _25
ENGLISH
Main parts
Air flow blade
Air intake
Air filter (under the grille)
Display
Display
Di
sp
la
y
Filter reset indicator
Fan indicator
Timer indicator
Power indicator
Power button
Remote control sensor
X PC2NUSMEN
2 WAY CASSETTE
Your air conditioner and display may look slightly different from the illustration shown above
depending on your model.
Your air conditioner and display may look slightly different from the illustration shown above
depending on your model.
Main parts
Display
Air flow blade
Air filter (under the grille)
Air intake
Indicator
Remote control sensor
Timer indicator
Removing frost indicator
On/Off operation indicator
Filter reset indicator
4 WAY CASSETTE
26_ using your air conditioner
using your air conditioner
TIPS ON USING AIR CONDITIONER
Here are some tips that you would follow when using your
air conditioner.
TOPIC RECOMMENDATION
Cooling • If current outside temperatures are
much higher than the selected indoor
temperature, it may take time to bring
the inner temperature to the desired
coolness.
• Avoid drastically turning down the
temperature. Energy is wasted and the
room does not cool faster.
Heating • Since the air conditioner heats the room
by taking heat energy from outdoor air,
the heating capacity may decrease when
outdoor temperatures are extremely low.
If you feel the air conditioner insufficiently
heats, using an additional heating
appliance in combination with the air
conditioner is recommended.
Frost & De-ice • When the air conditioner runs in Heat
mode, due to temperature difference
between the unit and the outside air, frost
will form.
If this happens:
- The air conditioner stops heating.
- The air conditioner will operate
automatically in De-ice mode for 10
minutes.
using your air conditioner _27
ENGLISH
Frost & De-ice - The steam produced on the outdoor unit
in De-ice mode is safe.
No intervention is required; after about
10 minutes, the air conditioner operates
again normally.
The unit will not operate when it starts
to de-ice.
Fan • Fan may not operate for about 3~5
minutes at the beginning to prevent any
cold blasts while the air conditioner is
warming up.
High indoor/
outdoor
temperatures
• If both indoor and outdoor temperatures
are high and the air conditioner is running
in Heat mode, the outdoor unit’s fan and
compressor may stop at times. This is
normal; wait until the air conditioner turns
on again.
Power failure • If a power failure occurs during the
operation of the air conditioner, the
operating immediately stops and unit
will be off. When power returns, the air
conditioner will run automatically.
Protection
mechanism
• If the air conditioner has just been turned
on after operation stops or being plugged
in, cool/warm air does not come out for 3
minutes to protect the compressor of the
outdoor unit.
28_ cleaning and maintaining
cleaning and maintaining the
air conditioner
For the best performance of your air conditioner, clean it
periodically. When cleaning, make sure to unplug the unit for
user’s safety.
CLEANING THE EXTERIOR
1. Wipe the surface of the unit with a slightly wet or dry cloth
when needed. Wipe off dirt of odd-shaped area by using a
soft brush.
Example : 4 way cassette
Do not use benzene or thinner.
They may damage the surface
of the air conditioner and can create a risk of fire.
CLEANING THE GRILLE
When cleaning the grille, make sure to unplug the unit. No
special tools are needed to clean it.
Slim 1 way cassette
1. Open the grille.
Press the [Push] signs (PC1NUSMAN : Located in 3 places) and open the grille.
X PC1NUPMAN
• When detaching the panel, grip the link part where the
panel and intake panel are connected ❶ and push up
the link at the panel part ❷ to disconnect as shown in
the picture (1).
• When power supply malfunctions, detach the panel by
using a driver at the marked point (2) and proceed with
the same method as shown in the picture (1) to detach
the panel and then check the power connection status.
CAUTION
X PC1NUSMAN
(2)
(1)
❶
❷
cleaning and maintaining _29
ENGLISH
2. Unhook the safety clips by holding the front grille.
3. Detach the front grille.
Hold the front grille at a 45° angle, lift it up slightly and then pull the grille forward.
Hold the grille to prevent dropping outside from
the opening of the front grille. If not, it may cause a
potential risk of personal injury.
Cleaning the grille is also available while being attached to the panel.
4. Pull out the Air filter.
Grab the Air filter and lift it upwards while pushing slightly, and then pull the Air filter forward.
5. Clean the grille with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
6. Insert the Air filter back in its original position.
7. Reattach the front grille.
Place the hook on the unit to the right place then push the front grille upward. Mount the
safety clips to its original position.
The illustration shown above may differ from yours depending on your model.
CAUTION
30_ cleaning and maintaining
cleaning and maintaining the
air conditioner
CLEANING THE GRILLE
2 way cassette
X PC2NUSMEN
1. Open the front grille.
Push the [W] tabs located in 3 places to unlock the groove on the front grille.
The grille automatically drops. Two safety clips are mounted to the inside front grille to
prevent dropping downward.
2. Unhook the safety clips by holding the front grille.
3. Detach the front grille.
Hold the front grille at a 45° angle, lift it up slightly and then pull the grille forward.
Hold the grille to prevent dropping outside from the
opening of the front grille. If not, izt may cause a
potential risk of personal injury.
Cleaning the grille is also available while being attached to the panel.
4. Pull out the Air filter.
Grab the Air filter and lift it upwards while pushing slightly, and then pull the Air filter forward.
5. Clean the grille with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
6. Insert the Air filter back in its original position.
7. Reattach the front grille.
Place the hook on the unit to the right place then push the front grille upward. Mount the
safety clips to its original position.
CAUTION
i t id f
H ld th ill t
cleaning and maintaining _31
ENGLISH
4 way cassette
X PC4NUSKAN / PC4NUSKEN / PC4NBSKAN
1. Open the front grille.
Open the blades on the left and right side of the
Samsung logo. Press both of the levers and pull the grille
downward. Two safety clips are mounted to the front
grille to prevent it from dropping.
2. Detach the front grille.
Remove the safety clip first and then remove
the hinge. Pull the green switch on the hinge
part down and then press and pull the hinge
part to remove the grillae. (There are two
hinges on the grille and you must apply this
step on both of them to remove the grille.)
❈
If you want to clean the filter only, you do
not have to detach the grille. Follow step 4 and 5
3.
Pull out the Air filter.
4.
Clean the grille and Air filter with a vacuum cleaner or soft brush.
If dust is too heavy, then rinse it with running water and dry it in a
ventilated area.
For best conditions, repeat every two weeks.
If the Air filter dries in a confined (or humid) area, odors may
generate. If it occurs, re-clean and dry it in a well-ventilated area.
5. Insert the Air filter back in its original position.
You will hear a click sound when the Air filter is properly placed.
6.
Attach the front grille.
Reverse the above steps to attach the front grille.
• The illustration shown above may differ from yours depending on your model.
• After cleaning the filter, press the Filter Reset button on the remote control for 2 seconds
to reset the filter schedule. Filter sign indicator will be on for cleaning time.
• If the angle on the air flow blades has been changed by user due to opening the front
grille for installation or maintenance, you must turn off the circuit breaker and turn it
on again before using the air conditioner. Otherwise, angles of the each angle can be
different or some of the blade may not close when the product is off.
32_ cleaning and maintaining
cleaning and maintaining the
air conditioner
CLEANING THE FILTER
When cleaning the filter, make sure to unplug the power
from the unit. Washable foam based Air filter captures large
particles from the air. The filter is cleaned with a vacuum or
by hand washing.
Slim 1 way cassette
1. Open the grille.
Press the [Push] signs (PC1NUSMAN : Located in 3 places) and open the grille.
X PC1NUPMAN
• When detaching the panel, grip the link part where the
panel and intake panel are connected ❶ and push up the
link at the panel part ❷ to disconnect as shown in the
picture (1).
• When power supply malfunctions, detach the panel by
using a driver at the marked point (2) and proceed with
the same method as shown in the picture (1) to detach
the panel and then check the power connection status.
2. Pull out the Air filter.
Grab the Air filter and lift it upwards while pushing
slightly, and then pull the Air filter forward.
When cleaning the filter you do not need to detach
the grille at all times. If you want to detach the front
grille, see step 2 and 3 on page 27 for instructions.
X PC1NUSMAN
(2)
(1)
❶
❷
cleaning and maintaining _33
ENGLISH
3. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
• For best conditions, repeat every two weeks.
• If the Air filter dries in a confined (or humid) area, odors may generate. If it occurs,
re-clean and dry it in a well-ventilated area.
4. Insert the Air filter back in its original position.
You will hear a click sound when the Air filter is properly placed.
5. Close the front grille by pushing it upward.
• The illustration shown above may differ from yours depending on your model.
• After cleaning the filter, press the Filter Reset button on the remote control for 2 seconds
to reset the filler schedule. Filter sign indicator will be on for cleaning time.
34_ cleaning and maintaining
cleaning and maintaining the
air conditioner
CLEANING THE FILTER
Slim 1 way cassette
1. Open the grille.
Pull the transparent part to open the grille.
Do not detach the grille since the filter can be detached while the grille is connected.
2. Detach the air filter.
Pull the filter handle to detach the filter.
3. Remove the dust on the filter with a vacuum cleaner or brush.
When there is too much dust on the filter, clean the filter softly with the tepid water in which a
neutral detergent is dissolved.
If you rub the filter together to wash it, the filter may get damaged.
Transparent part
X PC1MWSKAN X PC1NWSMAN/PC1BWSMAN
X PC1MWSKAN/PC1NWSMAN/PC1BWSMAN
cleaning and maintaining _35
ENGLISH
4. Dry the filter completely in the shade.
When drying the air filter, make sure the filter is not exposed to direct sunlight.
Otherwise, the form of the air filter may be changed.
5. Assemble the filter back and then close the grille.
If the center of the grille is not closed tightly,
press the center with hands to close the grille completely.
• When the indoor unit is used without the air filter,
the indoor unit may get damaged with dust.
• When opening the grille, you should grip the grille
until it hangs safely. Otherwise, the grille may fall
down, which may cause an injury.
• The grille is connected to the panel. Do not
forcibly detach the grille. If the connection
structure is broken, the grille may fall down,
which may cause an injury.
CAUTION
• Clean the air filter once in every 2 weeks. However, the cleaning period may differ
depending on the hours of filter use and service environment. Therefore, clean the filter
every week in a dusty area.
• If the filter reset indicator is turned on on the display ot the indoor unit, check and clean
the filter if it is dirty.
36_ cleaning and maintaining
cleaning and maintaining the
air conditioner
CLEANING THE FILTER
When cleaning the filter, make sure to unplug the power
from the unit. Washable foam based Air filter captures large
particles from the air. The filter is cleaned with a vacuum or
by hand washing.
2 way cassette
1. Open the front grille.
Push the [W] tabs located in 3 places to unlock the hook on the front grille.
The grille automatically drops. Two safety clips are mounted to the inside front grille to
prevent dropping downward.
2. Pull out the Air filter.
Grab the Air filter and lift it upwards while pushing slightly, and then pull the Air filter forward.
When cleaning the filter you do not need to detach the grille at all times. If you want to
detach the front grille, see step 2 and 3 on page 27 for instructions.
3. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
• For best conditions, repeat every two weeks.
• If the Air filter dries in a confined (or humid) area, odors may generate. If it occurs,
re-clean and dry it in a well-ventilated area.
4. Insert the Air filter back in its original position.
You will hear a click sound when the Air filter is properly placed.
cleaning and maintaining _37
ENGLISH
5. Close the front grille by pushing it upward.
After cleaning the filter, press the Filter Reset button on the remote control for 2 seconds
to reset the filler schedule. Filter sign indicator will be on for cleaning time.
4 way cassette
1. Push both of the tabs outwards to unlock the hook on the front grille.
The grille automatically drops. Two safety clips are mounted to the inside front grille to
prevent dropping downward.
2. Pull out the Air filter.
Grab the Air filter and lift it upwards while pushing slightly, and then pull the Air filter forward.
When cleaning the filter you do not need to detach the grille at all times. If you want to
detach the front grille, see step 2 and 3 on page 27 for instructions.
3. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
• For best conditions, repeat every two weeks.
• If the Air filter dries in a confined (or humid) area, odors may generate. If it occurs,
re-clean and dry it in a well-ventilated area.
4. Insert the Air filter back in its original position.
You will hear a click sound when the Air filter is properly placed.
5. Close the front grille by pushing it upward.
• The illustration shown above may differ from yours depending on your model.
• After cleaning the filter, press the Filter Reset button on the remote control for 2 seconds
to reset the filler schedule. Filter sign indicator will be on for cleaning time.
38_ cleaning and maintaining
cleaning and maintaining the
air conditioner
MAINTAINING YOUR AIR CONDITIONER
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in
best condition.
1. Dry the air conditioner thoroughly by operating
in Fan mode for 3 to 4 hours and disconnect the
power plug. There may be internal damage if
moisture is left in components.
2. Before using the air conditioner again, dry the inner
components of the air conditioner again by running
in Fan mode for 3 to 4 hours. This helps remove
odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type Description Monthly Every 4
months
Once a
year
Indoor unit
Clean the air filter (1)
O
Clean the condensate drain pan (2)
O
Thoroughly clean the heat exchanger (2)
O
Clean the condensate drain pipe (2)
O
Replace the remote control batteries (1)
O
Outdoor unit
Clean the heat exchanger on the outside of the
unit (2)
O
Clean the heat exchanger on the inside of the
unit (2)
O
Clean the electric components with jets of air (2)
O
Verify that all the electric components are firmly
tightened (2)
O
Clean the fan (2)
O
Verify that all the fan assembly is firmly
tightened (2)
O
Clean the condensate drain pan (2)
O
cleaning and maintaining _39
ENGLISH
The checks and maintenance operations described are essential to guarantee the
efficiency of the air conditioner. The frequency of these operations varies according to the
characteristics of the area, the amount of dust, etc.
(1) The described operations should be performed more frequently if the area of installation
is very dusty.
(2) These operations must always be performed
by qualified personnel. For more detailed
information, see the Installation Manual.
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type Description
Against cold air
The internal fan will be off to against cold air when the heat pump is
heating.
De-ice cycle
The internal fan will be off to against cold air when the heat pump is
heating.
Anti-protection of
internal battery
The compressor will be off to protect internal battery when the air con-
ditioner operates in Cool mode.
Protect compressor
The air conditioner does not start operating immediately to protect the
compressor of the outdoor unit after it has been started.
If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from
an outdoor unit that may have deposited at low temperatures.
The internal fan is switched off automatically and restarted only after the de-ice cycle is
completed.
40_ appendix
appendix
TROUBLESHOOTING
Refer to the following chart if the air conditioner operates
abnormally. This may save time and unnecessary expenses.
PROBLEM SOLUTION
The air
conditioner does
not operate
immediately
after it has been
restarted.
• Because of the protective
mechanism, the appliance does not
start operating immediately to keep
the unit from overloading.
The air conditioner will start in 3
minutes.
The air
conditioner does
not work at all.
• Check that the power plug is properly
connected. Insert the power plug into
the wall socket correctly.
• Check if the circuit breaker is
switched off.
• Check if there is a power failure.
• Check your fuse. Make sure it is not
blown out.
The temperature
does not change.
• Check if you selected Fan mode.
Press the Mode button on the remote
control to select another mode.
The cool (warm)
air does not
come out of the
air conditioner.
• Check if the set temperature is higher
(lower) than the current temperature.
Press the Temperature button on
the remote control to change the set
temperature. Press the Temperature
button to decrease or increase the
temperature.
• Check if the air filter is blocked by dirt.
Clean the air filter every two weeks.
appendix _41
ENGLISH
The cool (warm)
air does not
come out of the
air conditioner.
• Check if the air conditioner has just
been turned on. If so, wait 3 minutes.
Cool air does not come out to protect
the compressor of the outdoor unit.
• Check if the air conditioner is installed
in a place with a direct exposure to
sunlight. Hang curtains on windows
to boost cooling efficiency.
• Check if the cover or any obstacle is
not near the outdoor unit.
• Check if the refrigerant pipe is too
long.
• Check if the air conditioner is only
available in Cool mode.
• Check if the remote control is only
available for cooling model.
The fan speed
does not change.
• Check if you selected Auto or Dry
mode.
The air conditioner automatically
adjusts the fan speed to Auto in Auto/
Dry mode.
Timer function
does not set.
• Check if you press the Power button
on the remote control after you have set
the time.
Odors permeate
in the room
during operation.
• Check if the appliance is running in
a smoky area or if there is a smell
entering from outside. Operate the air
conditioner in Fan mode or open the
windows to air out the room.
The air
conditioner
makes a bubbling
sound.
• A bubbling sound may be heard
when the refrigerant is circulating
through the compressor. Let the air
conditioner operate in a selected
mode.
42_ appendix
appendix
PROBLEM SOLUTION
The air conditioner
makes a bubbling
sound.
• When you press the Power button on the
remote control, noise may be heard from
the drain pump inside the air conditioner.
Water is dripping
from the air flow
blades.
• Check if the air conditioner has been
cooling for an extended period of
time with the air flow blades pointed
downwards. Condensation may generate
due to the difference in temperature.
Remote control is
not working.
• Check if your batteries are depleted.
• Make sure batteries are correctly
installed.
• Make sure nothing is blocking your
remote control sensor.
• Check that there are strong lighting
apparatus near the air conditioner. Strong
light which comes from fluorescent bulbs
or neon signs may interrupt the electric
waves.
The air conditioner
does not turn on or
off with the wired
remote control.
• Check if you set the wired remote control
for group control.
The wired remote
control does not
operate.
• Check if TEST indicator is displayed on
the wired remote control. If so, turn off
the unit and switch off the circuit breaker.
Call your nearest contact center.
The indicators of
the digital display
flashes.
• Press the Power button on the remote
control to turn the unit off and switch
the circuit breaker off. Then, switch it on
again.
appendix _43
ENGLISH
OPERATION RANGES
The table below indicates the temperature and humidity
ranges the air conditioner can be operated within. Refer to
the table for efficient use.
MODE
Indoor temperature Outdoor temperature Indoor humidity
Cooling 18~32 °C -5~48 °C 80 % or less
Heating 27 °C or less -20~24 °C -
Drying 18~32 °C -5~48 °C -
MODEL SPECIFICATION (WEIGHT AND DIMENSION)
Type Model Net weight Net dimension (W x D x H)
Indoor unit
(NASA)
AM017HN1DEH/EU 8.0 kg 740 x 360 x 135 mm
AM022HN1DEH/EU 8.0 kg 740 x 360 x 135 mm
AM022FN1DEH/EU 10.5 kg 970 x 410 x 135 mm
AM028FN1DEH/EU 10.5 kg 970 x 410 x 135 mm
AM036FN1DEH/EU 10.5 kg 970 x 410 x 135 mm
AM056JN1DEH/EU 14.5 kg 1200 x 450 x 138 mm
AM071JN1DEH/EU 14.5 kg 1200 x 450 x 138 mm
AM056FN2DEH/EU 21.0 kg 890 x 575 x 230 mm
AM071FN2DEH/EU 21.0 kg 890 x 575 x 230 mm
AM045FN4DEH/EU 15.5 kg 840 x 840 x 204 mm
AM056FN4DEH/EU 15.5 kg 840 x 840 x 204 mm
AM071FN4DEH/EU 15.5 kg 840 x 840 x 204 mm
AM090FN4DEH/EU 15.5 kg 840 x 840 x 204 mm
AM112FN4DEH/EU 17.0 kg 840 x 840 x 246 mm
AM128FN4DEH/EU 19.0 kg 840 x 840 x 288 mm
AM140FN4DEH/EU 19.0 kg 840 x 840 x 288 mm
AM060KN4FEH/EU 21.0 kg 840 x 840 x 288 mm
AM071KN4FEH/EU 21.0 kg 840 x 840 x 288 mm
AM080KN4FEH/EU 21.0 kg 840 x 840 x 288 mm
44_ installing your air conditioner
Indoor Unit Installation
It is recommended to install the Y- joint before installing the indoor
unit.
1. Place the pattern sheet on the ceiling at the spot where you
want to install the indoor unit.
Since the diagram is made of paper, it may shrink
or stretch slightly due to temperature or humidity.
For this reason, before drilling the holes maintain
the correct dimensions between the markings.
Note
2. Insert bolt anchors, use existing ceiling supports or construct a
suitable support as shown in figure.
Concrete
Suspension bolt(Ø9.52 or M10)
Hole in anchor
Hole in plug
Insert
3. Install the suspension bolts depending on the ceiling type.
X
Ensure that the ceiling is strong enough to support
the weight of the indoor unit. Before hanging the
unit, test the strength of each attached suspension
bolt.
X
If the length of suspension bolt is more than 1.5 m, it
is required to prevent vibration.
X
If this is not possible, create an opening on the false
ceiling in order to be able to use it to perform the
required operations on the indoor unit.
Ceiling support
4. Screw eight nuts to the suspension bolts making space for
hanging the indoor unit.
You must install the suspension bolts more than four
when installing the indoor unit.
Nut
Washer
Rubber
Fasten the nut
CAUTION
CAUTION
5. Check the level of the indoor unit by using a leveler.
X A tilt of the indoor unit
may cause malfunction of
a built-in float switch and
water leaks.
Level
6. Adjust the height of the indoor unit by using the gauge of
dimensions.
X You should adjust the jigs and the pattern sheet to fit the
cutting dimensions of ceiling.
X Noise may occur if you do not adjust the location of the indoor
unit according to location of the jigs during installation.
- Adjust the location of the indoor unit according to the jigs.
X Make sure that the indoor unit is installed at a level if the
indoor unit slants too much, there can be water leaks.
X AM✴✴✴HN1DEH✴ models have installation guide on the
product. Make sure to adjust the height of the suspension bolt
so that surface of the ceiling and the installation guide on the
indoor unit is parallel to each other.
Slim 1 way cassette
Side view
Air inlet Air outlet
15 mm
15 mm
Jig Ceiling
AM777FN1DEH7/AM777JN1DEH7AM777HN1DEH7
❇ Make sure surface of the ceiling and the installation
guide is parallel to each other.
135 mm
155 mm
Installation guide
Location of the installation guide
NN NN
CeilingCeiling
Ceiling
17mm
20 mm
Indoor unit
Jig
2 way cassette 4 way cassette
AM777FN2DEH7AM777FN4DEH7/AM777KN4FEH7
7. Tighten the upper part nuts.
8. Remove the gauge of dimensions after installing the indoor
unit.
Performing Leak Test & Insulation
J The designs and shape are subject
to change according to the model.
LEAK TEST WITH NITROGEN(before opening valves)
In order to detect basic refrigerant leaks, before recreating the
vacuum and recirculating the R-410A, it’s responsible of installer
to pressurize the whole system with nitrogen(using a pressure
regulator) at a pressure above 4.1MPa(gauge).
LEAK TEST WITH R-410A(after opening valves)
Before opening valves, discharge all the nitrogen into the
system and create vacuum. After opening valves check leaks
using a leak detector for refrigerant R-410A.
Leak test
Discharge all the nitrogen to create a vacuum and
charge the system.
Installation Part
Leak check
installing your air conditioner _45
ENGLISH
1. To avoid condensation problems, place T13.0 or thicker
Acrylonitrile Butadien Rubber separately around each
refrigerant pipe.
Always make the seam of pipes face upwards.
Note
No gap
NBR(T13.0 or thicker)
2. Wind insulating tape around the pipes and drain hose avoiding
to compress the insulation too much.
Insulation cover pipe
Indoor unit
Be sure to overlap
the insulation
Insulation pipe
Must fit tightly against
body without any gap.
3. Finish wrapping insulating tape around the rest of the
pipes leading to the outdoor unit.
4. The pipes and electrical cables connecting the indoor unit
with the outdoor unit must be fixed to the wall with
suitable ducts.
Once you have checked that there are no leaks in the system,
you can insulate the piping and hose.
Insulation
Drain pipe and Drain Hose Installation
1. Install the drain pipe as shortly as possible.
X Give a slightly slant to the drainpipe for proper drainage of
condensate water.
X There must be no gap on the connected part so that the
drainpipe is not separated from the flexible hose.
2. Insulate the drainpipe, and then fix it as indicated.
X Whole drainpipe should be insulated by 5t(or more)
insulation to prevent water condensation.
Insulation drainpipe
Band Band
Flexible
hose
Drain
hose port
Drainpipe
Adhesives
Insulation cover band
Insulation cover drain
Band(Not supplied)
Indoor
Unit
All refrigerant connection must be accessible, in order
to permit either unit maintenance or removing it
completely.
X Install the insulation not to get wider and use the adhesives on the
connection part of it to prevent moisture from entering.
X Wind the refrigerant pipe with insulation tape if it is exposed to
outside sunlight.
X Install the refrigerant pipe respecting that the insulation does not
get thinner on the bent part or hanger of pipe.
X Add the additional insulation if the insulation plate gets thinner.
Additional insulation
Refrigerant pipe insulation
a×3
a
Hanger
5. Select the insulation of the refrigerant pipe.
X Insulate the gas side and liquid side pipe referring to the
thickness according to the pipe size.
X
Indoor temperature of 30 °C and humidity of 85% is the standard
condition. If installing in a high humidity condition, use one grade
thicker insulator by referring to the table below.
X Insulator’s heat-resistance temperature should be more
than 120 °C.
7When installing insulation in places and conditions below, use the
same insulation that is used for high humidity conditions.
<Geological condition>
- High humidity places such as shoreline, hot spring, near lake or
river, and ridge (when the part of the building is covered by earth
and sand.)
<Operation purpose condition>
- Restaurant ceiling, sauna, swimming pool etc.
<Building construction condition>
- The ceiling frequently exposed to moisture and cooling is not
covered.
e.g. The pipe installed at a corridor of a dormitory and studio or
near an exit that opens and closes frequently.
- The place where the pipe is installed is highly humid due to the
lack of ventilation system.
Pipe Pipe size
Insulation Type (Heating/Cooling)
Remarks
Standard
[30 °C, 85%]
High humidity
[30 °C, over 85%]
EPDM,NBR
Liquid
pipe
Ø6.35 ~ Ø9.52 9 t o
Internal
temperature
is higher than
120°C
Ø12.7 ~ Ø50.80 13 t o
Gas pipe
Ø6.35 13 t 19 t
Ø9.52 ~ Ø25.40 19 t 25 t
Ø28.58 ~ Ø44.45 32 t
Ø50.80 25 t 38 t
46_ installing your air conditioner
JFlexible hose Installation
1. The drain pipe should be installed within 100mm from the
flexible hose, lift up from 100mm to 550mm and lift down
20mm or more.
2. Install horizontal drainpipe with a slope of 1/100 or more
and fix it by hanger space of 1~1.5 m.
3. Install the air vent in the horizontal drainpipe to prevent
water flow back to the indoor unit.
You may not need to install it if there were proper
slope in the horizontal drainpipe.
Note
4. The flexible hose should not be installed upward position,
it may cause water flow back to the indoor unit.
5. Install U-trap at the end of the drainpipe to prevent a nasty
smell to reach the indoor unit.
Drainpipe Connection
Flexible hose
Air vent
300mm or less
Horizontal drainpipe
more than 1/100 slope
100~550mm
or less
1~1.5 m
100mm
or more
Ceiling
Hanger
1. Install main air vent at the front of the farthest indoor unit from
the main drain when installed indoor units are more than 3.
2. You may need to install individual air vent to prevent water
flow back at the top of each indoor unit drainpipe.
Centralized Drainage
Hanger
Main drainpipe Individual
air vent
Main air vent
Centralized horizontal drainpipe
(more than 1/100 slope)
550mm or less
1~1.5 m
X Install horizontally
Be horizontal
Indoor
Unit
Flexible hose
X Max. allowable axis gap
Max. 20mm
Indoor
Unit
X Max. allowable bending
angle
Max. 30˚
Indoor
Unit
X Handle with using adhesive not to
block the inside of flexible hose
Connect
to PVC
drain pipe
Connect to
indoor unit
Insulation
PVC
drain pipe
(Apply
adhesive on
the inside)
Insulation
Flexible hose
(Apply adhesive on
the outside)
Wiring Work
Silver solder
1. Before wiring work, you must turn off all power source.
2. Indoor unit power should be supplied through the
breaker(MCCB, ELB) separated by the outdoor power.
3. The power cable should be used only copper wires.
4. Connect the power cable{1(L), 2(N)} among the units within
maximum length and communication cable(F1, F2) each.
5. Connect F3, F4(for communication) when installing the
wired remote Control.
Power and communication cable connection
NL
NLNLNL
Indoor Unit 1
Outdoor
Unit
Wired Remote
Control
220-240V~
K ELB : Essential Installation
K Ceiling, wall-mounted indoor unit.
Indoor Unit 2 Indoor Unit 3
Indoor Unit 4 Indoor Unit 5 Indoor Unit 6
EEV kit
Selecting compressed ring terminal
Norminal
dimensions
for cable
(mm
2
)
Norminal
dimensions
for screw
(mm)
BDd1EFLd2t
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm) Min. Min. Max.
Standard
dimension
(mm)
Allowance
(mm) Min.
1.5 4 6.6 ±0.2 3.4 +0.3
-0.2 1.7 ±0.2 4.1 6 16 4.3 +0.2
00.7
48
2.5 4 6.6 ±0.2 4.2 +0.3
-0.2 2.3 ±0.2 6 6 17.5 4.3 +0.2
00.8
4 8.5
4 4 9.5 ±0.2 5.6 +0.3
-0.2 3.4 ±0.2 6 5 20 4.3 +0.2
00.9
Specification of electronic wire
Power supply MCCB ELB Power
cable
Earth
cable
Communication
cable
Max : 242 V
Min : 198 V XAXA, 30 mmA
0.1 s 2.5mm
2
2.5mm
2
0.75~1.5mm
2
X Decide the capacity of ELB and MCCB by below formula.
The capacity of ELB, MCCB X[A] = 1.25 X 1.1 X ∑Ai
7X
: The capacity of ELB, MCCB
7∑
Ai : Sum of Rating currents of each indoor unit.
7
Refer to each installation manual about the rating current of indoor unit.
X Decide the power cable specification and maximum length
within 10% power drop among indoor units.
7Coef: 1.55
7Lk: Distance among each indoor unit[m],
Ak: Power cable specification[mm
2
], ik: Running current of each unit[A]
∑ ( Coef×35.6×Lk×ik)< 10% of input
voltage[V]
1000×Ak
n
k=1
installing your air conditioner _47
ENGLISH
Setting an indoor unit address and installation option
Set the indoor unit address and installation option with remote controller option.
Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting option at the same
time. You need to set twice when setting indoor unit address and installation option.
The procedure of option setting
Step 1. Entering mode to set option
1. Remove batteries from the remote controller.
2. Insert batteries and enter the option setting mode while pressing High Temp button and Low Temp button.
3. Check if you have entered the option setting status.
Step 2. The procedure of option setting
After entering the option setting status, select the option as listed below.
Option setting is available from SEG1 to SEG 24
X SEG1, SEG7, SEG13, SEG19 are not set as page option.
X Set the SEG2~SEG6, SEG8~SEG12 as ON status and SEG14~18, SEG20~24 as OFF status.
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
0XXXXX1XXXXX
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
2XXXXX3XXXXX
On(SEG1~12) O(SEG13~24)
MR-DC00, MR-DH00
High Temp Button
High Fan Button
Mode change
Low Temp Button Low Fan Button
Entering mode for
option setting
Option setting
mode
MR-EC00, MR-EH00
High Temp Button
High Fan Button
Mode change
Low Temp Button Low Fan Button
Entering mode for
option setting
Option setting
mode
❋ The display of the remote controller may be dierent depending on the model.
48_ installing your air conditioner
Setting an indoor unit address and installation option
Option setting Status
1. Setting SEG2, SEG3 option
Press Low Fan button(
∨
) to enter SEG2 value.
Press High Fan button(
∧
) to enter SEG3 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG2 SEG3
2. Setting Cool mode
Press Mode button to be changed to Cool mode in the ON status.
3. Setting SEG4, SEG5 option
Press Low Fan button(
∨
) to enter SEG4 value.
Press High Fan button(
∧
) to enter SEG5 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG4 SEG5
4. Setting Dry mode
Press Mode button to be changed to DRY mode in the ON status.
5. Setting SEG6, SEG8 option
Press Low Fan button(
∨
) to enter SEG6 value.
Press High Fan button(
∧
) to enter SEG8 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG6 SEG8
6. Setting Fan mode
Press Mode button to be changed to FAN mode in the ON status.
7. Setting SEG9, SEG10 option
Press Low Fan button(
∨
) to enter SEG9 value.
Press High Fan button(
∧
) to enter SEG10 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG9 SEG10
8. Setting Heat mode
Press Mode button to be changed to HEAT mode in the ON status.
9. Setting SEG11, SEG12 option
Press Low Fan button(
∨
) to enter SEG11 value.
Press High Fan button(
∧
) to enter SEG12 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG11 SEG12
10. Setting Auto mode
Press Mode button to be changed to AUTO mode in the OFF status.
11. Setting SEG14, SEG15 option
Press Low Fan button(
∨
) to enter SEG14 value.
Press High Fan button(
∧
) to enter SEG15 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG14 SEG15
installing your air conditioner _49
ENGLISH
Option setting Status
12. Setting Cool mode
Press Mode button to be change to Cool mode in the OFF status.
13. Setting SEG16, SEG17 option
Press Low Fan button(
∨
) to enter SEG16 value.
Press High Fan button(
∧
) to enter SEG17 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG16 SEG17
14. Setting Dry mode
Press Mode button to be change to Dry mode in the OFF status.
15. Setting SEG18, SEG20 option
Press Low Fan button(
∨
) to enter SEG18 value.
Press High Fan button(
∧
) to enter SEG20 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG18 SEG20
16. Setting Fan mode
Press Mode button to be change to Fan mode in the OFF status.
17. Setting SEG21, SEG22 option
Press Low Fan button(
∨
) to enter SEG21 value.
Press High Fan button(
∧
) to enter SEG22 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG21 SEG22
18. Setting Heat mode
Press Mode button to be change to HEAT mode in the OFF status.
19. Setting SEG23, SEG24 mode
Press Low Fan button(
∨
) to enter SEG23 value.
Press High Fan button(
∧
) to enter SEG24 value.
Each time you press the button,
⋯
will be selected in rotation.
SEG23 SEG24
Step 4. Input option
Press the operation button with the direction of remote control for set.
For the correct option setting, you must input the option twice.
Step 5. Check operation
1. Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit.
2. Take the batteries out of the remote controller and insert them again and then press the operation button.
Step 3. Check the option you have set
After setting an option, press button to check whether the option code you input is correct or not.
50_ installing your air conditioner
Setting an indoor unit address and installation option
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power
supply in the indoor unit.
2. The panel(display) should be connected to an indoor unit to receive option.
3. Before installing the indoor unit, assign an address to the indoor unit according
to the air conditioning system plan.
Setting an indoor unit address (MAIN/RMC/MCU)
Indoor Unit
1(L) F2
F1
2(N)
X When “A”~”F” is entered to SEG5~6, the indoor unit MAIN ADDRESS is not changed.
X If you set the SEG 3 as 0, the indoor unit will maintain the previous MAIN ADDRESS even if you input the option value of SEG5~6.
X If you set the SEG 9 as 0, the indoor unit will maintain previous RMC ADDRESS even if you input the option value of SEG11~12.
X You cannot set SEG11 and SEG12 as F value at the same time.
X If the indoor unit is connected to the MCU, you can set the SEG 15~18.
Ex.) If you want to set the indoor unit to ‘A’ port of MCU #1. (0A0000 – 100000 – 20101A -30000)
Option No. : 0AXXXX-1XXXXX-2XXXXX-3XXXXX
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE Setting Main address 100-digit of indoor
unit address 10-digit of indoor unit The unit digit of an
indoor unit
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0A
0No Main
address
0~9 100-digit 0~9 10-digit 0~9 A unit
digit
1
Main
address
setting
mode
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE
-
Setting RMC address
-
Group channel(*16) Group address
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
1
0No RMC
address
RMC1 0~F RMC2 0~F
1
RMC
address
setting
mode
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation PAGE
-
Setting MCU PORT
address
10-digit of MCU
address
1-digit of MCU MCU PORT address
Indication
and Details
Indication Details
-
Indication Details Indication Details Indication Details Indication Details
2
0
No MCU
PORT
0~1 10-digit 0~9 1-digit A~F PORT
Location
1
MCU
PORT
address
setting
mode
4. Assign an indoor unit address by wireless remote controller.
- The initial setting status of indoor unit ADDRESS(MAIN/RMC/MCU port) is “0A0000-100000-200000-300000.”
• Also set the MCU and Indoor units address by using Add-on > Change address on S-NET Pro 2.
(For more information, see the S-NET Pro 2 Help.)
• From SEG13 to SEG18 is for setting MCU address.
- MCU models that can set address: MCU-S✴NEK2N, MCU-S4NEK3N, MCU-S1NEK1N
Note
installing your air conditioner _51
ENGLISH
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power
supply in the indoor unit.
2. The panel(display) should be connected to an indoor unit to receive option.
3. Set the installation option according to the installation condition of an air
conditioner.
- The default setting of an indoor unit installation option is
“020010-100000- 200000-300000”.
- Individual control of a remote controller(SEG20) is the function that controls an
indoor unit individually when there is more than one indoor unit.
Setting an indoor unit installation option (suitable for the condition of each installation location)
Indoor Unit
1(L) F2
F1
2(N)
4. Set the indoor unit option by wireless remote controller.
X 1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to ‘USE + 3minute delay’ even if the drain pump is set to 0.
X 1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using filter(SEG18) will be set to ‘1000hour’ even if the SEG18 is set to
except for 2 or 6.
X When setting the option other than above SEG values, the option will be set as “0”.
X SEG5 central control option is basically set as 1 (Use), so you don’t need to set the central control option additionally.
However, if the central control is not connected but it doesn’t indicate an error message, you need to set the central control
option as 0 (Disuse) to exclude the indoor unit from the central control.
X
The output of hot water heater in SEG9 is generated from the hot coil part of the terminal board in duct models.
F4
F3
F1 F2
V2
V1
1(L) 2(N)
2
1
HOT
COIL
AC
POWER
OUTDOOR
COMMUNICATION
Wire Remote
Controller
DC 12V
* The output of hot coil terminal is AC 220 V / 230 V
(The same as Indoor Unit’s input Power)
COM1 COM2
(+)
L N (-)
X
The external output of SEG15 is generated by MIM-B14 connection. (Refer to the manual of MIM-B14.)
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
0 2 Evaporator Drying
Use of external
room temperature
sensor / Minimizing
fan operation when
thermostat is o
Use of central control FAN RPM compensation
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1 Use of drain pump Use of hot water heater - EEV Step when
heating stops -
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2 Use of external control
Setting the output
of external control /
External heater signal
/ Cooling operation
signal / Free Cooling
control signal
S-Plasma ion Buzzer control Hours of lter usage
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3Individual control of a
remote controller
Heating setting
compensation /
Removing condensate
water in heating mode
Adjusted EEV step of
stopped unit during oil
return /defrost mode.
Motion detect sensor -
Q
02 series installation option
52_ installing your air conditioner
Setting an indoor unit address and installation option
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE Evaporator Drying
Use of external room temperature sensor /
Minimizing fan operation when thermostat
is o
Use of central
control FAN RPM compensation
Indication
and Details
Indication Details Indication Details Indication Details
Indication
Details
Indication Details Indication Details
Use of
External room
temperature
sensor
Minimizing fan
operation when
thermostat is o
02
0 Disuse
0 Default Default
0 Disuse
0 Disuse
1 Use Disuse
2 Disuse Use (Heating) (*2)
2 Use (5min) (*1)
3 Use Use (Heating) (*2)
4 Disuse Use (Cooling) (*2)
1
RPM
compensation
5 Use Use (Cooling) (*2)
4 Use (10min) (*1)
6 Disuse Use (Heating /
Cooling) (*2)
1Use
7Use
Use (Heating /
Cooling) (*2)
8 Disuse Use (Cooling Ultra
Low Fan ) (*2)
2
High ceiling
KIT (4way
model only)
6 Use (30min) (*1)
9Use
Use (Cooling Ultra
Low Fan ) (*2)
A Disuse
Use (Heating /
Cooling Ultra Low
Fan ) (*2)
BUse
Use (Heating /
Cooling Ultra Low
Fan ) (*2)
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE Use of drain pump Use of hot water heater EEV Step when
heating stops
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
1
0 Disuse 0 Disuse 0 Default
1 Use 1 Use (*3)
1
Adjusted
EEV Step
setting
2
When an
indoor
unit stops,
drain
pump will
operate
for 3min
3 Use (*3)
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation PAGE Use of external
control
Setting the output of external
control / External heater signal /
Cooling operation signal /
Free Cooling control signal
S-Plasma ion Buzzer control Hours of lter usage
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
2
0 Disuse 0 External control
(Thermo On)
0 Disuse 0 Use
buzzer 2 1000 Hour1"ON/OFF
control"
1External control
(Operation On)
2External heater
signal (*4)
2"OFF
control"
3External heater
signal (*4)
4Cooling operation
signal (*5)
1Use1
Disuse
buzzer 6 2000 Hour
3
"Window
ON/OFF
control"
5
Free Cooling control
(Cooling Thermo
On) (*6)
6
Free Cooling control
(Cooling/Dry
Thermo On) (*6)
Q
02 series installation option (Detailed)
installing your air conditioner _53
ENGLISH
Option SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
Explanation PAGE Individual control of a
remote controller
Heating setting compensation / Removing
condensate water in heating mode
Adjusted EEV step of
stopped unit during oil
return /defrost mode.
Motion detect sensor
Indication
and Details
Indication Details Indication Details Indication
Details
Indication Details Indication Details
Heating Setting
Compensation
Removing
Condensate
Water in
Heating
Mode
3
0 or 1 channel 1 0 Default Disuse
0 Default
0 Disuse
1 2 °C Disuse 1
Turn out in 30min. without motion
2 channel 2 2 5 °C Disuse 2
Turn out in 60min. without motion
3 Default Use (*7) 3
Turn out in 120min. without motion
3 channel 3
4
Turn out in 180min. without motion
4 2 °C Use (*7)
1
Adjusted
EEV
positon
5
Turn out in 30min. without motion
or *advanced function
4 channel 4
6
Turn out in 60min. without motion
& *advanced function
5 5 °C Use (*7)
7
Turn out in 120min. without motion
& *advanced function
8
Turn out in 180min. without motion
& *advanced function
* Advanced function: Controlling cooling/heating current or power saving with motion detect.
(*1) When Cooling or dry mode is o. The indoor fan operate in setting minutes.
(*2) Minimizing fan operation when thermostat is o
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
- Fan stops or operates Ultra low in Cooling when thermostat is o.
(*3) 1: Fan is turned on continually when the hot water heater is turned on,
3: Fan is turned o when the hot water heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option, install the Mode Select switch(MCM-C200) on the outdoor unit and x it as cool mode.
(*4) When the following 2 or 3 is used as external heater On/O signal, the signal for monitoring external contact control will not be output.
2: Fan is turned on continually when the external heater is turned on,
3: Fan is turned o when the external heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option, install the Mode Select switch(MCM-C200) on the outdoor unit and x it as cool mode.
- If Fan is set to o for cooling only indoor unit by setting the SEG9=3 or SEG15=3, you need to use an external sensor or wired remote
controller sensor to detect indoor temperature exactly.
(*5) When indoor unit is in cooling or Dry mode, The output signal is “ON”
(*6) For free cooling control, Economizer controller is required.
(*7) If the air conditioner operates the heating mode immediately after nishing the cooling mode, the condensate water in the drain pan becomes
water vapor by the heat of the indoor unit heat exchanger. Since the water vapor might be condensed on the indoor unit, which may fall into
a living space, use this function to get rid of the water vapor out of the indoor unit by operating the fan (for maximum 20 minutes) even when
the indoor unit is turned o after cooling mode is turned to heating mode .
X Do not install the electronic heater in the flow channel of the indoor unit fan.
Air Flow
Suction side Discharge side
Electronic heater should
not be installed.
Duct Indoor unit
54_ installing your air conditioner
Setting an indoor unit address and installation option
Option No. : 05XXXX-1XXXXX-2XXXXX-3XXXXX
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE
Use of Auto Change Over
for HR only in Auto mode /
Use of Cooling only indoor
unit of HR
(When setting SEG3)
Standard heating temp.
Oset
(When setting SEG3)
Standard cooling temp.
Oset
(When setting SEG3)
Standard for mode change
Heating → Cooling
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
05
0
Follow
product
option
0 0 °C 0 0 °C 0 1 °C
1 0.5 °C 1 0.5 °C 1 1.5 °C
1
Use Auto
Change Over
for HR only
2 1 °C 2 1 °C 2 2 °C
3 1.5 °C 3 1.5 °C 3 2.5 °C
4 2 °C 4 2 °C 4 3 °C
2
Use Cooling
only indoor
unit for HR
5 2.5 °C 5 2.5 °C 5 3.5 °C
6 3 °C 6 3 °C 6 4 °C
7 3.5 °C 7 3.5 °C 7 4.5 °C
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE
(When setting SEG3)
Standard for mode
change Cooling →
Heating
(When setting SEG3)
Time required for mode
change
Compensation option
for Long pipe or height
dierence between indoor
units
MTFC (*3)
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details
1
0 1 °C 0 5min 0 Default
0 Default
1 1.5 °C 1 7min
1
(*1) Height
dierence is
more than
30m or (*2)
Distance is
longer than
110m
2 2 °C 2 9min
3 2.5 °C 3 11min
4 3 °C 4 13min
2
(*1) Height
dierence is
15~30m or
(*2) Distance is
50~110m
2Use
5 3.5 °C 5 15min
6 4 °C 6 20min
7 4.5 °C 7 30min
Q
05 series installation option (Detailed)
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
05
Use of Auto Change Over
for HR only in Auto mode
/ Use of Cooling only
indoor unit of HR
(When setting SEG3)
Standard heating temp.
Oset
(When setting SEG3)
Standard cooling temp.
Oset
(When setting SEG3)
Standard for mode change
Heating
→
Cooling
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1
(When setting SEG3)
Standard for mode change
Cooling → Heating
(When setting SEG3) Time
required for mode change
Compensation option
for Long pipe or height
dierence between indoor
units
MTFC (*3) -
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2----
Control variables when
using hot water / external
heater (*4)
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3- - -
Forced FAN Operation for
Heating and Cooling -
Q
05 series installation option
installing your air conditioner _55
ENGLISH
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation Control variables when using hot water / external heater (*4)
Indication
and Details
Indication Details Indication Details
Set temp. for heater On/O
Delay time for heater On
2
0
At the same time as thermo on
No delay
1
At the same time as thermo on
10 minutes
2
At the same time as thermo on
20 minutes
3 1.5 °C No delay
4 1.5 °C 10 minutes
5 1.5 °C 20 minutes
6 3.0 °C No delay
7 3.0 °C 10 minutes
8 3.0 °C 20 minutes
9 4.5 °C No delay
A 4.5 °C 10 minutes
B 4.5 °C 20 minutes
C 6.0 °C No delay
D 6.0 °C 10 minutes
E 6.0 °C 20 minutes
Option SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
Explanation PAGE Forcing FAN Operation for Heating and Cooling
Indication
and Details
Indication Details Indication Details
Cooling Fan Setting Heating Fan Setting
3
0
Disuse Disuse
1
Disuse Use (Fan: User setting)
2
Disuse Use (Fan: High)
3
Disuse Use (Fan: Low)
4
Use (Fan: User
setting) Disuse
5
Use (Fan: User
setting) Use (Fan: User setting)
6
Use (Fan: User
setting) Use (Fan: High)
7
Use (Fan: User
setting) Use (Fan: Low)
8
Use (Fan: High) Disuse
9
Use (Fan: High) Use (Fan: User setting)
A
Use (Fan: High) Use (Fan: High)
B
Use (Fan: High) Use (Fan: Low)
C
Use (Fan: Low) Disuse
D
Use (Fan: Low) Use (Fan: User setting)
E
Use (Fan: Low) Use (Fan: High)
F
Use (Fan: Low) Use (Fan: Low)
(*1) Height dierence : The dierence of the height between the corresponding indoor unit and the indoor unit installed at the lowest place.
For example, When the indoor unit is installed 40m higher than the indoor unit installed at the lowest place, select the option
“1”.
(*2) Distance : The dierence between the pipe length of the indoor unit installed at farthest place from an outdoor unit and the pipe length of the
corresponding indoor unit from an outdoor unit.
For example, when the farthest pipe length is 100 m(328 ft.) and the corresponding indoor unit is 40 m away from an outdoor unit,
select the option “2”. (100 - 40 = 60m)
(*3) For MTFC option, MTFC(Multi Tenant Function Controller) kit is required.
(*4) Heater operation when the SEG9 of 02 series installation option is set to using hot water heater or when SEG15 is set to using external heater
e.g. 1) Setting 02 series SEG9 =”1” / Setting 05 series SEG18 = “0”: Hot water heater is turned on at the same time as the heating thermostat is
on, and turned o when the heating thermostat is o.
e.g. 2) Setting 02 series SEG15 =”2” / Setting 05 series SEG18 =”A”:Room temp. ≤ set temp. + f(heating compensation temp.)
- External heater is turned on when the temperature is maintained as 4.5 °C for 10 minutes. Room temp. > set temp. + f(heating
compensation temp.)
- External heater is turned o when the temperature is maintained as 4.5 °C + 1 °C (1 °C is the Hysteresis for On/O selection.)
56_ installing your air conditioner
Setting an indoor unit address and installation option
SEG 3, 4, 5, 6, 8, 9 additional information
When the SEG 3 is set as "1" and follow Auto Change Over for HR only operation, it will operate as follows.
Cooling/Heating mode can be changed when Thermo O status is maintained during the time with SEG9.
A : Set with SEG4(˚C)
B : Set with SEG5(˚C)
C : Set with SEG6(˚C)
D : Set with SEG8(˚C)
Cooling Thermo O
Heating Thermo O
Cooling Thermo On
Heating Thermo On
BC
D
Ts
A
c
a
Temp.
d
b
Standard temp.
for Heating
Standard temp.
for Cooling
Standard temp. for
Heating
→
Cooling
Standard temp.
for Cooling
→
Heating
Set temp.
for Auto mode
installing your air conditioner _57
ENGLISH
Changing a particular option
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE The option mode
you want to change
The tens’ digit of an
option SEG you will
change
The unit digit of an
option SEG you will
change
Changed value
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0D
Option
mode 1~6 Tens’ digit
of SEG 0~9 Unit digit of
SEG 0~9
The
changed
value
0~F
You can change each digit of set option.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE The option mode
you want to change
The tens’ digit of an
option SEG you will
change
The unit digit of an
option SEG you will
change
Changed value
Indication 0 D 2 1 7 1
• When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’.
• When changing a digit of indoor unit installation option, set the SEG3 as ‘2’.
Ex) When setting the ‘buzzer control’ into disuse status.
Note
58_ installing your air conditioner
Memo
installing your air conditioner _59
ENGLISH
Memo
QUESTIONS OR COMMENTS?
DB68-03568A-10
COUNTRY CALL OR VISIT US ONLINE AT
UK 0330 SAMSUNG (7267864) www.samsung.com/uk/support
IRELAND (EIRE) 0818 717100 www.samsung.com/ie/support
GERMANY 06196 77 555 77 *OTH www.samsung.com/de/support
FRANCE 01 48 63 00 00 www.samsung.com/fr/support
ITALIA 800-SAMSUNG (800.7267864) www.samsung.com/it/support
SPAIN 0034902172678 www.samsung.com/es/support
PORTUGAL 808 207 267 www.samsung.com/pt/support
LUXEMBURG 261 03 710 www.samsung.com/be_fr/support
NETHERLANDS 088 90 90 100 www.samsung.com/nl/support
BELGIUM 02-201-24-18 www.samsung.com/be/support (Dutch)
www.samsung.com/be_fr/support (French)
NORWAY 21629099 www.samsung.com/no/support
DENMARK ߨߡߨߡߢߪߨߡ www.samsung.com/dk/support
FINLAND 030-6227 515 иииࢋϑɇϑЇ˝ࢋʀͱࢥѣࢥϑЇΧΧͱθϩ
SWEDEN 0771 726 786 www.samsung.com/se/support
POLAND
801-172-678* lub +48 22 607-93-33*
Uʪʒцͱиɇɇ˙ͱɇʒͱͱɵϑЇ˝іɇΧцϩɇʒͱϩцʀіɦʀцʀ˵
telefonów komórkowych: 801-672-678* lub +48 22 607-93-33*
ࡐ࣍ͱΧɇϩɇиʪʒЇ˝ϩɇθц˙цͱΧʪθɇϩͱθɇ࣎
http://www.samsung.com/pl/support/
HUNGARY 0680SAMSUNG (0680-726-7864) www.samsung.com/hu/support
AUSTRIA
0800-SAMSUNG (0800-7267864)
[Only for KNOX customers] 0800 400848
[Only for Premium HA] 0800-366661
[Only for Dealers] 0810-112233
[Only for E-Store] 0800 100 232
www.samsung.com/at/support
SWITZERLAND 0800 726 78 64 (0800-SAMSUNG) www.samsung.com/ch/support (German)
www.samsung.com/ch_fr/support (French)
CZECH 800 - SAMSUNG (800-726786) иииࢋϑɇϑЇ˝ࢋʀͱࢥʀіࢥϑЇΧΧͱθϩ
SLOVAKIA 0800 - SAMSUNG (0800-726 786) www.samsung.com/sk/support
CROATIA 072 726 786 www.samsung.com/hr/support
BOSNIA 055 233 999 www.samsung.com/support
MONTENEGRO 020 405 888 www.samsung.com/support
SLOVENIA ߡߩߡߧߪߨߣߧߨ࣍ɵθʪіΧɇʄɇϕϩʪЭɇ࣎ www.samsung.com/si/support
SERBIA 011 321 6899 www.samsung.com/rs/support
ALBANIA 045 620 202 www.samsung.com/al/support
BULGARIA ࡐߤߡߡߡҬԧԸԜԟԷԼԧԨԜԾԜ
ߡߩߡߡߢߢߢߤߢࡡ҈ԧԪԺԵԜԾԸԜԾԧԵԧՂԹԸԸԜԵԬԸԬ՟ www.samsung.com/bg/support
ROMANIA *8000 (apel in retea)
08008-726-78-64 (08008-SAMSUNG) Apel GRATUIT www.samsung.com/ro/support
CYPRUS 8009 4000 only from landline, toll free
www.samsung.com/gr/support
GREECE 80111-SAMSUNG (80111 726 7864) only from land line
(+30) 210 6897691 from mobile and land line
LITHUANIA 8-800-77777 www.samsung.com/lt/support
LATVIA 8000-7267 иииࢋϑɇϑЇ˝ࢋʀͱࢥЭࢥϑЇΧΧͱθϩ
ESTONIA 800-7267 www.samsung.com/ee/support
SAMSUNG ELECTR ONICS CO., LTD .
107, Hanamsandan 6beon-ro, Gwangsan-gu, Gwangju-si, Korea 62218
Samsung Electronics
ƊʪθЭʀʪUʪΧɇθϩʪϩ
PO Box 12987, Blackrock, Co. Dublin. Ireland
or
Blackbushe Business Park, Yateley, GU46 6GG. UK