Samsung AM056FNJDEH User Manual
Displayed below is the user manual for AM056FNJDEH by Samsung which is a product in the Split-System Air Conditioners category. This manual has pages.
Related Manuals
2
Contents
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g.
charger, headset, USB cable) should not be disposed of with other household waste at the end of their working
life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please
separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of
material resources.
Household users should contact either the retailer where they purchased this product, or their local government
office, for details of where and how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This
product and its electronic accessories should not be mixed with other commercial wastes for disposal.
For information on Samsung’s environmental commitments and product specific regulatory obligations e.g.
REACH visit: samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html
Safety Information 4
Viewing your air conditioner before use 11
Basic Operation 15
Auto
Cool
Dry
Fan
Heat
Turning the air conditioner on
Selecting the operation mode
Adjusting the temperature
Selecting the fan speed
Selecting air flow direction
Advanced Operation 19
Setting the On timer
Setting the Off timer
Using the Purity function
Controlling Indoor Units
Cleaning and Maintaining the air conditioner 24
Appendix 29
Installation part 32
3
ENGLISH
Safety Information
Before using your new air conditioner, please read this manual
thoroughly to ensure that you know how to safely and efficiently
operate the extensive features and functions of your new appliance.
Because the following operating instructions cover various models,
the characteristics of your air conditioner may differ slightly from
those described in this manual. If you have any questions, call your
nearest contact centre or find help and information online at www.
samsung.com.
WARNING
Hazards or unsafe practices that may result in severe personal
injury or death.
CAUTION
Hazards or unsafe practices that may result in minor personal
injury or property damage.
Follow directions. Do NOT attempt.
Make sure the machine is grounded to prevent electric shock.
Cut off the power supply. Do NOT disassemble.
FOR INSTALLATION
WARNING
Use the power line with the power specifications of the
product or higher and use the power line for this appliance
only. In addition, do not use an extension line.
• Extending the power line may result in electric shock or fire.
• Do not use an electric transformer. This may result in electric
shock or fire.
4
• If the voltage/frequency/rated current condition is different,
it may cause fire.
The installation of this appliance must be performed by a
qualified technician or service company.
• Failing to do so may result in electric shock, fire, explosion,
problems with the product, or injury and may also void
warranty on the installed product.
Install an Isolation Switch next to the Air Conditioner (but
not on the panels of the Air Conditioner) and circuit breaker
dedicated to the air conditioner.
• Failing to do so may result in electric shock or fire.
Fix the outdoor unit firmly so that the electric part of the
outdoor unit is not exposed.
• Failing to do so may result in electric shock, fire, explosion,
or problems with the product.
Do not install this appliance near a heater, or inflammable material.
Do not install this appliance in a humid, oily or dusty location, in a
location exposed to direct sunlight and water (rain drops). Do not
install this appliance in a location where gas may leak.
• This may result in electric shock or fire.
Never install the outdoor unit in a location such as on a high
external wall where it could fall.
• If the outdoor unit falls, it may result in injury, death or
property damage.
This appliance must be properly grounded. Do not ground the
appliance to a gas pipe, plastic water pipe, or telephone line.
• Failure to do so may result in electric shock, fire, an
explosion, or other problems with the product.
• Make sure to use a socket-outlet with ground.
Safety Information
5
ENGLISH
CAUTION
Please cover the air conditioner with PE BAG after installation,
and remove it when you start to run air conditioner.
Install your appliance on a level and hard floor that can
support its weight.
• Failing to do so may result in abnormal vibrations, noise, or
problems with the product.
Install the drain hose properly so that water drains correctly.
• Failing to do so may result in water overflowing and
property damage. Avoid adding drain to waste pipes as
odours may arise in the future.
When installing the outdoor unit, make sure to connect the
drain hose so that draining is performed correctly.
• The water generated during the heating operation in the
outdoor unit may overflow and result in property damage.
In particular, in winter, if a block of ice falls, it may result in
injury, death or property damage.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest
service centre.
Do not pull or excessively bend the power line. Do not twist
or tie the power line. Do not hook the power line over a metal
object, place a heavy object on the power line, insert the
power line between objects, or push the power line into the
space behind the appliance.
• This may result in electric shock or fire.
6
CAUTION
When not using the air conditioner for a long period of time or
during a thunder/lightning storm, cut the power at the circuit
breaker.
• Failing to do so may result in electric shock or fire.
FOR USING
WARNING
If the appliance is flooded, please contact your nearest service
centre.
• Failing to do so may result in electric shock or fire.
If the appliance generates a strange noise, a burning smell or
smoke, cut off the power supply immediately and contact the
nearest service centre.
• Failing to do so may result in electric shock or fire.
In the event of a gas leak (such as propane gas, LP gas, etc.),
ventilate immediately without touching the power line. Do not
touch the appliance or power line.
• Do not use a ventilating fan.
• A spark may result in an explosion or fire.
To reinstall the air conditioner, please contact your nearest
service centre.
• Failing to do so may result in problems with the product,
water leakage, electric shock, or fire.
• Delivery service for the product is not provided. If you
reinstall the product in another location, additional
construction expenses and an installation fee will be charged.
Safety Information
7
ENGLISH
• Especially, when you wish to install the product in an
unusual location such as in an industrial area or near the
seaside where it is exposed to salt in the air, please contact
your nearest service centre.
Do not touch the circuit breaker with wet hands.
• This may result in electric shock.
Do not turn the air conditioner off with the circuit breaker
while it is operating.
• Turning the air conditioner off and then on again with the
circuit breaker may cause a spark and result in electric shock
or fire.
After unpacking the air conditioner, keep all packaging
materials well out of the reach of children, as packaging
materials can be dangerous to children.
• If a child places a bag over its head, it may result in
suffocation.
Do not touch the front panel with your hands or fingers during
the heating operation.
• This may result in electric shock or burns.
Do not insert your fingers or foreign substances into the air
inlet/outlet of the air conditioner.
• Take special care that children do not injure themselves by
inserting their fingers into the product.
Do not strike or pull the air conditioner with excessive force.
• This may result in fire, injury, or problems with the product.
Do not place an object near the outdoor unit that allows
children to climb onto the machine.
• This may result in children seriously injuring themselves.
8
Do not use this air conditioner for long periods of time in badly
ventilated locations or near infirm people.
• Since this may be dangerous due to a lack of oxygen, open a
window at least once an hour.
If any foreign substance such as water has entered the appliance,
cut the power by unplugging the power plug and turning the
circuit breaker off and then contact your nearest service centre.
• Failing to do so may result in electric shock or fire.
Do not attempt to repair, disassemble, or modify the appliance
yourself.
• Do not use any fuse (such as copper, steel wire, etc.) other
than the standard fuse.
• Failing to do so may result in electric shock, fire, problems
with the product, or injury.
CAUTION
Do not place objects or devices under the indoor unit.
• Water dripping from the indoor unit may result in fire or
property damage.
Check that the installation frame of the outdoor unit is not
broken at least once a year.
• Failing to do so may result in injury, death or property
damage.
Max current is measured according to IEC standard for safety
and current is measured according to ISO standard for energy
efficiency.
Do not stand on top of the appliance or place objects (such as
laundry, lighted candles, lighted cigarettes, dishes, chemicals,
metal objects, etc.) on the appliance.
Safety Information
9
ENGLISH
• This may result in electric shock, fire, problems with the
product, or injury.
Do not operate the appliance with wet hands.
• This may result in electric shock.
Do not spray volatile material such as insecticide onto the
surface of the appliance.
• As well as being harmful to humans, it may also result in
electric shock, fire or problems with the product.
Do not drink the water from the air conditioner.
• The water may be harmful to humans.
Do not apply a strong impact to the remote control and do not
disassemble the remote control.
Do not touch the pipes connected with the product.
• This may result in burns or injury.
Do not use this air conditioner to preserve precision
equipment, food, animals, plants or cosmetics, or for any other
unusual purposes.
• This may result in property damage.
Avoid directly exposing humans, animals or plants to the air
flow from the air conditioner for long periods of time.
• This may result in harm to humans, animals or plants.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, without supervision
or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
10
For use in Europe : This appliance can be used by children aged from
8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
FOR CLEANING
WARNING
Do not clean the appliance by spraying water directly onto it.
Do not use benzene, thinner, alcohol or acetone to clean the
appliance.
• This may result in discolouration, deformation, damage,
electric shock or fire.
Before cleaning or performing maintenance, cut off the power
supply and wait until the fan stops.
• Failing to do so may result in electric shock or fire.
CAUTION
Take care when cleaning the surface of the heat exchanger of
the outdoor unit since it has sharp edges.
• This should be done by a qualified technician. Please contact
your installer or service centre.
Do not clean the inside of the air conditioner by yourself.
• For cleaning inside the appliance, contact your nearest
service centre.
• When cleaning the filter, refer to the descriptions in the
‘Cleaning at a Glance’ section.
• Failing to do so may result in damage, electric shock or fire.
Safety Information
11
ENGLISH
viewing your air conditioner before use
Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air
conditioner and stay cool or warm with optimal efficiency.
Please read the user manual to get started and to make the best use of the air conditioner.
CHECKING THE INDOOR UNIT
Carefully unpack your air conditioner, and check the unit to make sure it is not damaged.
Main parts
Your air conditioner may slightly look different from illustration shown above depending on your model.
Mode indicator and Control button
Air intake
Mode indicator and
Control button
Air outlet
(Cooling/Heating)
Air outlet
(Heating)
Blade pin lever
Blade pin lever
Ionizer indicator
Fan mode indicator
Timer indicator
Remote control sensor
Power indicator
Power button
Deice indicator
12
viewing your air conditioner before use
REMOVING THE FRONT PANEL
Grab the top portion of the front panel and pull the front cover towards yourself. Unhook the safety string
and lift up the front panel.
Viewing the power button and parts under the panel
You may locate the Power button among with the mode indicators. When the front panel is open, you may
locate the temperature sensor and the Air flow switch. Temperature sensor is located on the top left side of
the air conditioner just above the anti-allergy/deodorizing filter slot and the Air flow switch is located on the
top right corner of the air conditioner.
You can turn on the air conditioner in Auto mode by pressing the Power button.
When you set the Air flow switch on Auto, it will open the bottom air outlet in Cool, Heat and Fan modes.
However, in Silence mode, the bottom air outlet will be closed. Also, in Cool mode, the bottom air outlet will
be closed within an hour. When you set the Air flow switch on Off, the bottom air outlet will be closed.
The room temperature sensor measures indoor room temperature.
Auto Off
Auto Off
Auto Off
Air flow switch
Power button
Room temperature sensor
13
ENGLISH
01
05
06
07
08
09
16
17
18
20
21
02
03
04
11
12
13
19
14
15
10
01 Set temperature indicator
02 Timer option indicator
03 Operation mode indicator
04 Options indicator
05 Low battery indicator
06 Transmit indicator
07 Fan speed indicator
08 Vertcal air swing indicator
09 Horizontal air swing indicator
NOTE
• This function is not available in this model.
10 Settings indicator
11 Power button
12 Temperature button
13 Options button
14 Timer button
15 Direction button/Selection button
16 Vertical air swing button
17 Mode button
18 Fan speed button
19 Horizontal air swing button
NOTE
• This function is not available in this model.
20 Settings button
21 SET button
NOTE
• The air conditioner may not be operated by
the remote control if the controller is placed
close to strong light such as a fluorescent
lamp or neon sign. In this case, use the
remote control right in front of the remote
control receiver of the indoor unit.
• If other electrical products are operated by the
remote control, call your nearest service center.
• To silence the beep sound, press the
Settings → <, > or Settings → (Beep)
blinking → SET button. When you press
the Settings → <, > or Settings → (Beep)
blinking → SET button again, the beep
sound will be active again.
14
viewing your air conditioner before use
Replacing batteries
When the icon appears in the remote control
display, replace the batteries with new ones.
Two 1.5V AAA type batteries are required.
Correct disposal of batteries in this product
(Applicable in countries with separate collection systems)
This marking on the battery, manual or packaging indicates that the batteries in this product should not be
disposed of with other household waste at the end of their working life. Where marked, the chemical symbols
Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC
Directive 2006/66. If batteries are not properly disposed of, these substances can cause harm to human health
or the environment.
To protect natural resources and to promote material reuse, please separate batteries from other types of waste
and recycle them through your local, free battery return system.
Storing the remote control
If the remote control will not be used for an
extended period of time, store it in the remote
control holder with the batteries removed.
CAUTION
• Make sure that water does not come into the
remote control.
two 1.5V AAA type batteries
15
ENGLISH
Basic Operation
Auto
In Auto mode, the air conditioner will automatically adjust
the temperature and fan speed to maintain your fresh
environment.
• When the indoor temperature is too high, the powerful
cool breeze is generated and when the indoor room
becomes cool enough, the soft breeze is generated.
Cool
The Cool mode is frequently used and you can freely control
the temperature, fan speed, and air flow direction in Cool
mode.
• When you select the Heat mode while the Cool mode is on,
the Cool mode is cancelled.
Dry
The air conditioner in Dry mode acts like a dehumidifier by
removing moisture from the indoor air. The Dry mode will
provide you with fresh air even on a rainy day.
Fan
The Fan mode provides you with a breeze just like a fan to
make fresh environment for you.
16
Heat
In Heat mode, you can warm your room even in fall and
winter.
• The fan may not commence immediately to avoid
generating a cold breeze.
• In Heat mode, defrost operation may be performed to
remove the frost formed on the outdoor unit. (When the
frost is removed by the defrost operation in Heat mode,
steam is generated from the outdoor unit.)
• If you stop operating the air conditioner after heating
operation, the fan will operate for some time to cool the
indoor unit.
• When you select the Cool mode while the Heat mode is on,
the Heat mode is cancelled.
NOTE
• When the outdoor temperature is relatively low and the
humidity is relatively high in Heat mode, the outdoor unit's
heating capacity may decrease due to the frost formed on
the outdoor heat exchanger. The defrost operation removes
the frost formed on the heat exchanger of the outdoor unit
for 5 to 12 minutes. During the defrost operation, the indoor
unit does not generate breeze in order to prevent cold breeze
blowing out.
– The interval between defrost operations can decrease
depending on the amount of the frost formed on the
outdoor unit.
– The interval between defrost operations can also decrease
depending on the humidity level in the air.
Basic Operation
17
ENGLISH
Turning the air conditioner on
Press the button to operate the air conditioner.
Selecting the operation mode
Press the button to select an operation mode.
►►►
►
Adjusting the temperature
Press the button to adjust the temperature.
Mode Temperature control
Auto/Cool/
Dry Adjust by 1 °C between 18 °C and 30 °C.
Heat Adjust by 1 °C between 16 °C and 30 °C.
Fan Temperature cannot be adjusted.
Selecting the fan speed
Press the button to adjust the fan speed.
Mode Available fan speeds
Auto/Dry (Auto)
Cool/Heat (Auto), (Low), (Med), (High)
Fan (Low), (Med), (High)
18
Selecting air flow direction
Keep the air flow in a constant direction by stopping the
movements of the vertical and horizontal air flow blades.
In operation ►
NOTE
• If you adjust the vertical air flow blade manually, it may not
close completely when you turn off the air conditioner.
Horizontal air flow (manual)
Keep the horizontal air flow in a constant direction by
changing the directions of the horizontal air flow blades
manually.
NOTE
• Although you press the
button, this function does not
work.
CAUTION
• To prevent personal injury, make sure that you change the
directions of the horizontal air flow blades after stopping the
movements of the vertical air flow blade.
Remote control display
Basic Operation
19
ENGLISH
You can set the air conditioner to be turned on or off automatically at the desired time.
Setting the On timer
When the air conditioner is turned off:
1. Press the button to select (On).
• The (On) indicator will keep blinking and you can set the time.
2. Press the or button to set the time.
• You can set the time in half hour intervals from
30minutes (0.5 on the display) to 3in hour intervals
from 3 to 24 hours.
• The time can be set from minimum 30 minutes to
maximum 24hours.
3. Press the button to complete the On timer setting.
• The (On) indicator and the set time of the timer will be
displayed on the remote control display.
• On timer setting will be cancelled if you don't press the
button within 10seconds after setting the time.
Therefore, check for the (On) indicator on the remote
control display.
Cancel
Press the button ► select (On) ► press
the or button ► set the timer to
► press the button
Remote control display
Additional options available in the On timer
Select the mode in the following order: (Auto) ► (Cool) ► (Dry) ► (Fan) and ► (Heat).
You can adjust the temperature after timer setting is completed.
Temperature adjustment is only available in Auto, Cool, Dry, and Heat modes. In Fan
mode, the temperature cannot be adjusted.
NOTE
• When On timer setting is completed, the setting will be displayed for 3 seconds, and then only the
(On) indicator will remain on the remote control display.
• You cannot set the Fan speed when setting the On timer.
Advanced Operation
20
Setting the Off timer
When the air conditioner is turned on:
1. Press the button to select (Off).
• The (Off) indicator will keep blinking and you can set the time.
2. Press the or button to set the time.
• You can set the time in half hour intervals from
30minutes (0.5 on the display) to 3 hours and in hour
intervals from 3 to 24 hours.
• The time can be set from minimum 30 minutes to
maximum 24 hours.
3. Press the button to complete the Off timer setting.
• The (Off) indicator and the set time of the timer will be
displayed on the remote control display.
• Off timer setting will be cancelled if you don't press the
button within 10seconds after setting the time.
Therefore, check for the (Off) indicator on the remote
control display.
Cancel
Press the button ► select (Off) ► press
the or button ► set the timer to
► press the button
NOTE
• Only the latest timer setting will be applied between the Off
timer and good’ sleep off timer functions.
Remote control display
Combining On timer and Off timer
When the air conditioner is turned off When the air conditioner is turned on
When the set time on On timer is less than that on
Off timer
e.g. On timer: 3hours, Off timer: 5hours
• The air conditioner will be turned on after
3hours from the moment you have set the
timer and the air conditioner will remain on for
2hours and then be turned off automatically.
When the set time on On timer is greater than that
on Off timer
e.g. On timer: 3hours, Off timer: 1hour
• The air conditioner will be turned off after
1hour from the moment you have set the
timer and will be automatically turned on after
2hours from the moment it was turned off.
NOTE
• The set times for the On timer and the Off timer should be different from each other.
• After the On timer or the Off timer is set, the setting can be cancelled by pressing the button.
Advanced Operation
21
ENGLISH
Using the Purity function
When the air conditioner is turned on
1. Press the button.
2. Press the , or button until the
( )
indicator starts blinking.
3. Press the button to set the Purity function.
( ) ( ) indicator will be displayed on the remote controller
display and Ionizer function will begin.
Cancel
Press the button ► press the , or
to make the
( ) i
indicator blink and press the
button.
NOTE
• You may select the purity function additionally during
Auto/Cool/Dry/Heat mode and you can adjust the
temperature.
• If the purity function is selected additionally in fan mode,
the temperature cannot be adjusted.
• When the air conditioner and the purity function are
turned on simultaneously and you press the Power
button, both air conditioner and purity function will stop
operation.
• You can still use the purity function when the On timer is
set with the air conditioner is turned off.
• There will not be much difference on energy consumption
and operating noise when the purity function is selected
additionally while the air conditioner is turned on.
Remote control display
Purity function will remove harmful materials in the air to provide you clean and healthy
environment.
You can select this function additionally while the air conditioner is in operation.
22
Advanced Operation
When the air conditioner is turned off
1. Press the button.
2. Press the button when ( ) indicator blinks to
begin purity function.
• ( ) ( ) indicator will be displayed on the remote
controller display and Ionizer function will begin.
Cancel Press the button to make the ( )
indicator blink and press the button.
Remote control display
23
ENGLISH
You can individually select and operate indoor units among 4 indoor units.
Controlling Indoor Units
When the air conditioner is turned on:
1. Press the button.
2. Press the , or button until the (Zone)
indicator starts blinking.
3. Press the button to select the indoor unit to operate.
• You can select individual units in order of 1 to 4 or select
all indoor units at one time.
Remote control display
24
CLEANING THE EXTERIOR
1. Wipe the surface of the unit with a slightly wet or dry cloth when
needed.
Do not use Benzene, Thinner or CloroxTM.
They may damage the surface of the air conditioner and can create
a risk of fire.
CLEANING THE FILTER
When cleaning the filter, make sure to unplug the power from the unit. No special tools are needed to clean
it.
Air filter
Washable air filter captures large particles from the air. The filter is cleaned with a vacuum or by
hand washing. Filter clean indicator will light up when air filter need to be cleaned.
1. Open the front panel.
Grab the top portion of the front panel and
pull the front cover towards yourself. Unhook
the safety string and lift up the front panel.
2. Grab the handle and slightly
press the air filter down to bent
the air filter. Then, pull the Air
filter towards you and lift it up to
remove the Air filter.
3. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
• For the best conditions, repeat every two weeks.
• If the Air filter dries in a confined (or humid) area, odors may generate. If it occurs,
re-clean and dry it in a well-ventilated area.
4. Insert the Air filter back in its original position.
5. Close the front panel.
Grab the side of the front panel and place the bottom first, then push the panel.
Auto Off
Auto Off
CAUTION
cleaning and maintaining the air conditioner
25
ENGLISH
Anti-allergy filter
Washable Anti-allergy filter leads to reduction in allergens that thrive in polluted air. The filter is cleaned
with a vacuum or by hand washing.
1. Open the front panel.
Grab the top portion of the front panel and pull
the front cover towards yourself. Unhook the
safety string and lift up the front panel.
2. Grab the handle and slightly press the air filter down to bent the air filter. Then, pull the Air filter
towards you and lift it up to remove the Air filter.
3. Pull and slide out the Anti-allergy filter.
4. Clean the Anti-allergy filter with a vacuum cleaner or soft brush. Then rinse it with running water
and dry it in a ventilated area.
5. Install the Anti-allergy filter back in position.
6. Close the front panel.
Grab the side of the front panel and place the bottom first, then push the panel.
Clean the Anti-allergy filter every 3 months. The cleaning term may differ on usage and
environmental conditions.
26
REPLACING THE FILTER
Replacement filter may be purchased from the retail store or ordered from the dealer where you purchased
the unit. If you cannot find one, please call a contact center.
Deodorizing filter
Deodorizing filter absorbs efficiently cigarette smoke, pet odors and other unpleasant smells.
Deodorizing filter cleaning is simple, just remove old filter and install a new one.
1. Open the front panel.
Grab the top portion of the front panel and
pull the front cover towards yourself. Unhook
the safety string and lift up the front panel.
2. Grab the handle and slightly press the air filter down to bent the air filter. Then, pull the Air
filter towards you and lift it up to remove the Air filter.
3. Pull and slide out the Deodorizing filter.
4. Install the new Deodorizing filter back in position.
5. Close the front panel.
Grab the side of the front panel and place the bottom first, then push the panel.
• The replacement timing of the Deodorizing filter differs depending on usage and
environmental conditions.
• Even if Deodorizing and Anti-allergy filters are installed in an inverted position it will not
significantly affect its filtration system.
cleaning and maintaining the air conditioner
27
ENGLISH
MAINTAINING YOUR AIR CONDITIONER
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in
best condition.
1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect
the power plug. There may be internal damage if moisture is left in components.
2. Before using the air conditioner again, dry the inner components of the air conditioner again
by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated
from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type Description Monthly Every 4
months
Once a
year
Indoor unit
Clean the air filter (1)
Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the condensate drain pipe (2)
Replace the remote control batteries (1)
Outdoor unit
Clean the heat exchanger on the outside of
the unit (2)
Clean the heat exchanger on the inside of
the unit (2)
Clean the electric components with jets of
air (2)
Verify that all the electric components are
firmly tightened (2)
Clean the fan (2)
Verify that all the fan assembly is firmly
tightened (2)
Clean the condensate drain pan (2)
The checks and maintenance operations described are essential to guarantee the
efficiency of the air conditioner. The frequency of these operations varies according to the
characteristics of the area, the amount of dust, etc.
(1) The described operations should be performed more frequently if the area of installation
is very dusty.
(2) These operations must always be performed by qualified personnel. For more detailed
information, see the Installation Manual.
28
MAINTAINING YOUR AIR CONDITIONER
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type Description
Against cold air
The internal fan will be off to against cold air when the heat pump is
heating.
De-ice cycle
The internal fan will be off to against cold air when the heat pump is
heating.
Anti-protection of
internal battery
The compressor will be off to protect internal battery when the air
conditioner operates in Cool mode.
Protect compressor
The air conditioner does not start operating immediately to protect the
compressor of the outdoor unit after it has been started.
If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from
an outdoor unit that may have deposited at low temperatures.
The internal fan is switched off automatically and restarted only after the de-ice cycle is
completed.
cleaning and maintaining the air conditioner
29
ENGLISH
Appendix
TROUBLESHOOTING
Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary
expenses.
PROBLEM SOLUTION
The air conditioner does
not operate immediately
after it has been
restarted.
• Because of the protective mechanism, the appliance does not start
operating immediately to keep the unit from overloading.
The air conditioner will start in 3 minutes.
The air conditioner does
not work at all.
• Check that the power plug is properly connected. Insert the power plug
into the wall socket correctly.
• Check if the circuit breaker is switched off.
• Check if there is a power failure.
• Check your fuse. Make sure it is not blown out.
The temperature does
not change.
• Check if you selected Fan mode.
Press the Mode button on the remote control to select another mode.
The cool(warm) air does
not come out of the air
conditioner.
• Check if the set temperature is higher (lower) than the current
temperature. Press the Temperature button on the remote control to
change the set temperature. Press the Temperature or button to
increase or decrease the temperature.
• Check if the air filter is blocked by dirt. Clean the Air filter every two weeks.
• Check if the air conditioner has just been turned on. If so, wait 3 minutes.
The fan speed does not
change.
• Check if you selected Auto or Dry mode.
The air conditioner automatically adjusts the fan speed to Auto in Auto/Dry
mode.
Timer function does not
set.
• Check if you press the Set/Cancel button on the remote control after you
have set the time.
Odors permeate in the
room during operation.
• Check if the appliance is running in a smoky area or if there is a smell
entering from outside. Operate the air conditioner in Fan mode or open
the windows to air out the room.
The air conditioner
makes a bubbling sound.
• A bubbling sound may be heard when the refrigerant is circulating through
the compressor. Let the air conditioner operate in a selected mode.
Water is dripping from
the air flow blades.
• Check if the air conditioner has been cooling for an extended period of
time with the air flow blades pointed downwards. Condensation may
generate due to the difference in temperature.
Remote control is not
working.
• Check if your batteries are depleted.
• Make sure batteries are correctly installed.
• Make sure nothing is blocking your remote control sensor.
• Check that there are strong lighting apparatus near the air conditioner.
Strong light which comes from fluorescent bulbs or neon signs may
interrupt the electric waves.
30
OPERATION RANGES
The table below indicates the temperature and humidity ranges the air conditioner can be operated within.
Refer to the table for efficient use.
MODE OPERATIONAL TEMPERATURE INDOOR HUMIDITY IF OUT OF CONDITIONS
INDOOR OUTDOOR
COOLING 18˚C to 32˚C -5˚C to 48˚ 80% or less
Condensation may occur on
the indoor unit with risk to have
either water blow off or drops on
the floor.
HEATING 27˚C or less -20˚C to 28˚C - Internal protection triggers and
the air conditioner will stop.
DRYING 18˚C to 32˚C -5˚C to 48˚C -
Condensation may occur on
the indoor unit with risk to have
either water blow off or drops on
the floor.
The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below,
the heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.
Dimension and weight
Type Model Net dimension (WxDxH) (mm) Net weight (kg)
Indoor unit
AM028FNJDEH/EU 720*620*199 16
AM036FNJDEH/EU 720*620*199 16
AM056FNJDEH/EU 720*620*199 16
AM022KNJDEH/EU 720*620*199 15.5
AM045KNJDEH/EU 720*620*199 16
Model specification (Dimension and weight)
Appendix
31
ENGLISH
Memo
32
Performing Leak Test & Insulation
LEAK TEST WITH NITROGEN(before opening valves)
In order to detect basic refrigerant leaks, before recreating the
vacuum and recirculating the R410A, it’s responsible of installer
to pressurize the whole system with nitrogen(using a pressure
regulator) at a pressure above 4.1MPa(gauge).
LEAK TEST WITH R410A(after opening valves)
Before opening valves, discharge all the nitrogen into the
system and create vacuum. After opening valves check leaks
using a leak detector for refrigerant R410A.
Leak test
6. The pipes & cable should be gone through the bottom
back hole.
7.
Hanging the indoor unit on the Bracket Hanger, then x the
Indoor Unit by using 4 Screws.
Case 1. Installing on the floor : Must fix 4 screws on the wall,
make the indoor not to fall down(For safety installation).
Case 2. Hanging on the wall : Follow the installation guide
supplied in the accessory part.
Screw positions are specified on the installation guide.
1. When you install the indoor with side-pipe connection,
please make space more than 300mm from the wall.
2. When you install the indoor at the inclined floor, please
lean the set toward the drain hose and pipe connection to
prevent water overflowing.
3. Please remove the items when set is installed.
AM028/036FNJD : 6 Items
AM056FNJD : 7 Items.
4. The body front should be opened to connect pipes.
Please release the 4 screws of body front and then pull it
out from the bottom of the set.
5. Make a hole on the wall.
300mm 300mm
Position
of drain
Position
of drain
Screw Hole
Screw Hole
Indoor Unit Installation
It is recommended to install the Y- joint before installing the
indoor unit.
Installation Part
Drain hose
Outside room
Inside room
75mm
Ø60~65mm
Less than 70mm Discharge all the nitrogen to create a vacuum and
charge the system.
33
ENGLISH
1. To avoid condensation problems, place T13.0 or thicker
Acrylonitrile Butadien Rubber separately around each
refrigerant pipe.
Always make the seam of pipes face upwards.
Note
2. Wind insulating tape around the pipes and drain hose
avoiding to compress the insulation too much.
3. Finish wrapping insulating tape around the rest of the
pipes leading to the outdoor unit.
4. The pipes and electrical cables connecting the indoor unit
with the outdoor unit must be fixed to the wall with
suitable ducts.
Once you have checked that there are no leaks in the system,
you can insulate the piping and hose.
Insulation
No gap
NBR(T13.0 or thicker)
5. Select the insulation of the refrigerant pipe.
Insulate the gas side and liquid side pipe referring to the
thickness according to the pipe size.
The thickness according to the pipe size is a standard of
the indoor temperature of 27°C and humidity of 80%.
If installing in an unfavorable conditions, use thicker one.
Insulator’s heat-resistance temperature should be more
than 120°C.
Pipe size
(mm)
Minimum thickness
of insulation (mm) Remarks
PE foam
EPDM
foam
Ø6.35~Ø15.88 13 10 If you install the pipe
underground, at the seaside,
a spa or on the lake, use 1 grade
thicker one according to the
pipe size.
-25 19
Insulation cover pipe
Indoor unit
Be sure to overlap
the insulation
Drain hose installation
When installing the drain hose for the indoor unit,
check if condensation draining is adequate.
When passing the drain hose through the 65mm hole drilled
in the wall, check the following:
The hose must
NOT slant upwards.
The end of the drain hose must
NOT be placed under water.
Do NOT bend the hose in
different directions.
Keep a clearance of at least
5cm between the end of the
hose and the ground.
5cm
less
Do NOT place the end of the
drain hose in a hollow.
Ditch
Must fit tightly against body
without any gap.
All refrigerant connection must be accessible, in order
to permit either unit maintenance or removing it
completely.
Install the insulation not to get wider and use the
adhesives on the connection part of it to prevent
moisture from entering.
Wind the refrigerant pipe with insulation tape
if it is exposed to outside sunlight.
Install the refrigerant pipe respecting that the
insulation does not get thinner on the bent part or
hanger of pipe.
Add the additional insulation if the insulation
plate gets thinner.
Additional insulation
Refrigerant pipe insulation
a×3
a
Hanger
34
Wiring Work
Silver solder
Selecting compressed ring terminal
Norminal
dimensions
for cable
(mm
2
)
Norminal
dimensions
for screw
(mm)
B D d1 E F L d2 t
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm) Min. Min. Max.
Standard
dimension
(mm)
Allowance
(mm) Min.
1.5 46.6 ±0.2 3.4 +0.3
-0.2 1.7 ±0.2 4.1 616 4.3 +0.2
00.7
4 8
2.5 46.6 ±0.2 4.2 +0.3
-0.2 2.3 ±0.2 6 6 17.5 4.3 +0.2
00.8
48.5
4 4 9.5 ±0.2 5.6 +0.3
-0.2 3.4 ±0.2 6 5 20 4.3 +0.2
00.9
Specification of electronic wire
Power supply MCCB ELB or ELCB Power
cable
Earth
cable
Communication
cable
Max : 242V
Min : 198V XA X A, 30mmA
0.1 s 2.5mm
2
2.5mm
2
0.75~1.5mm
2
Decide the capacity of ELCB(or MCCB+ELB) by below formula.
Power supply cords of parts of appliances for outdoor use shall not
be lighter than polychloroprene sheathed flexible cord.
(Code designation IEC:60245 IEC 57 / CENELEC: H05RN-F or
IEC:60245 IEC 66 / CENELEC: H07RN-F
)
The capacity of ELCB(or MCCB+ELB) X [A] = 1.25 X 1.1 X ∑Ai
X
: The capacity of ELCB(or MCCB+ELB).
∑
Ai : Sum of Rating currents of each indoor unit.
Refer to each installation manual about the rating current of indoor unit.
Decide the power cable specification and maximum length
within 10% power drop among indoor units.
Coef: 1.55
Lk: Distance among each indoor unit[m],
Ak: Power cable specification[mm
2
], ik: Running current of each unit[A]
∑ ( Coef×35.6×Lk×ik) < 10% of input
voltage[V]
1000×Ak
n
k=1
1. If necessary, connect the 2 meter extension drain hose to
the drain hose.
2. If you use the extension drain hose, insulate the inside of
the extension drain hose with a shield.
3. Fit the drain hose into 1 of 2 drain hose holes, then fix the
end of the drain hose tightly with a clamp.
If you don’t use the other drain hose hole, block it with a
rubber stopper.
4. Pass the drain hose under the refrigerant pipe, keeping the
drain hose tight.
5. Pass the drain hose through the hole in the wall.
Check if it slants downwards as seen in the picture.
The hose will be fixed permanently into position
after finishing the installation and the gas leak test.
Shield
Drain hose Extension drain hose
(No default resource)
Drain hose installation
6-Ways to connect Drain Hose and Pipe
Knock out
➡
1. Before wiring work, you must turn off all power source.
2. Indoor unit power should be supplied through the
breaker(ELCB or MCCB+ELB) separated by the outdoor
power.
ELCB: Earth Leakage Circuit Breaker
MCCB:Molded Case Circuit Breaker
ELB:Earth Leakage Breaker
3. The power cable should be used only copper wires.
4. Connect the power cable{1(L), 2(N)} among the units within
maximum length and communication cable(F1, F2) each.
5. Connect F3, F4(for communication) when installing the
wired remote Control.
Power and communication cable connection
N L
N L N L N L
ELCB
MCCB+
ELB
V1 V2
Indoor Unit 1
Outdoor
Unit
Wired Remote
Control
220-240V~
ELCB : Essential Installation
Ceiling, wall-mounted indoor unit.
Indoor Unit 2 Indoor Unit 3
Indoor Unit 4 Indoor Unit 5 Indoor Unit 6
EEV kit
WARNING
Power off before connecting any wires;
Indoor PBA will be damaged while V1,V2,F3,F4
short each other.
or
35
ENGLISH
Set the indoor unit address and installation option with remote controller option.
Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting option at the same
time. You need to set twice when setting indoor unit address and installation option.
The procedure of option setting
Step 1. Entering mode to set option
1. Remove batteries from the remote controller.
2. Insert batteries and enter the option setting mode while pressing High Temp button and Low Temp button .
3. Check if you have entered the option setting status.
Step 2. The procedure of option setting
After entering the option setting status, select the option as listed below.
Option setting is available from SEG1 to SEG 24
SEG1, SEG7, SEG13, SEG19 are not set as page option.
Set the SEG2~SEG6, SEG8~SEG12 as ON status and SEG14~18, SEG20~24 as OFF status.
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
0XXXXX1XXXXX
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
2 X X X X X 3 X X X X X
On(SEG1~12) O(SEG13~24)
Setting an indoor unit address and installation option
Mode
Selects operation mode.
Air ow direction (Left and right)
Adjusts the air ow direction left and right.
Fan speed
Adjusts the fan speed.
Air ow direction (Up and down)
Adusts the air ow direction up and down (Not
applicable to Duct type models).
SET
Selects or cancels an option.
Settings
Selects settings.
Power
Turns the air conditioner on or o.
Temperature
Adjusts the temperature.
Options
Selects options during operation.
Direction
Moves to select and set an option.
Timer
Sets timer option.
36
Setting an indoor unit address and installation option
Option setting Status
1. Setting SEG2, SEG3 option
Press Low Fan button(
∨
) to enter SEG2 value.
Press High Fan button(
∧
) to enter SEG3 value.
Each time you press the button,
…
will be selected in rotation.
2. Setting Cool mode
Press Mode button to be changed to Cool mode in the ON status.
3. Setting SEG4, SEG5 option
Press Low Fan button(
∨
) to enter SEG4 value.
Press High Fan button(
∧
) to enter SEG5 value.
Each time you press the button,
…
will be selected in rotation.
4. Setting Dry mode
Press Mode button to be changed to DRY mode in the ON status.
5. Setting SEG6, SEG8 option
Press Low Fan button(
∨
) to enter SEG6 value.
Press High Fan button(
∧
) to enter SEG8 value.
Each time you press the button,
…
will be selected in rotation.
6. Setting Fan mode
Press Mode button to be changed to FAN mode in the ON status.
7. Setting SEG9, SEG10 option
Press Low Fan button(
∨
) to enter SEG9 value.
Press High Fan button(
∧
) to enter SEG10 value.
Each time you press the button,
…
will be selected in rotation.
8. Setting Heat mode
Press Mode button to be changed to HEAT mode in the ON status.
9. Setting SEG11, SEG12 option
Press Low Fan button(
∨
) to enter SEG11 value.
Press High Fan button(
∧
) to enter SEG12 value.
Each time you press the button,
…
will be selected in rotation.
10. Setting Auto mode
Press Mode button to be changed to AUTO mode in the OFF status.
11. Setting SEG14, SEG15 option
Press Low Fan button(
∨
) to enter SEG14 value.
Press High Fan button(
∧
) to enter SEG15 value.
Each time you press the button,
…
will be selected in rotation.
SEG2 SEG3
SEG4
SEG6
SEG9
SEG11
SEG14
SEG5
SEG8
SEG10
SEG12
SEG15
37
ENGLISH
Setting an indoor unit address and installation option
Option setting Status
12. Setting Cool mode
Press Mode button to be change to Cool mode in the OFF status.
13. Setting SEG16, SEG17 option
Press Low Fan button(
∨
) to enter SEG16 value.
Press High Fan button(
∧
) to enter SEG17 value.
Each time you press the button,
…
will be selected in rotation.
14. Setting Dry mode
Press Mode button to be change to Dry mode in the OFF status.
15. Setting SEG18, SEG20 option
Press Low Fan button(
∨
) to enter SEG18 value.
Press High Fan button(
∧
) to enter SEG20 value.
Each time you press the button,
…
will be selected in rotation.
16. Setting Fan mode
Press Mode button to be change to Fan mode in the OFF status.
17. Setting SEG21, SEG22 option
Press Low Fan button(
∨
) to enter SEG21 value.
Press High Fan button(
∧
) to enter SEG22 value.
Each time you press the button,
…
will be selected in rotation.
18. Setting Heat mode
Press Mode button to be change to HEAT mode in the OFF status.
19. Setting SEG23, SEG24 mode
Press Low Fan button(
∨
) to enter SEG23 value.
Press High Fan button(
∧
) to enter SEG24 value.
Each time you press the button,
…
will be selected in rotation.
SEG16
SEG18
SEG21
SEG23
SEG17
SEG20
SEG22
SEG24
Step 4. Input option
Press operation button with the direction of remote control for set.
For the correct option setting, you must input the option twice.
Step 5. Check operation
1. Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit.
2. Take the batteries out of the remote controller and insert them again and then press the operation button.
Step 3. Check the option you have set
After setting option, press button to check whether the option code you input is correct or not.
38
Setting an indoor unit address and installation option
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power
supply in the indoor unit.
2. The panel(display) should be connected to an indoor unit to receive option.
3. Before installing the indoor unit, assign an address to the indoor unit according
to the air conditioning system plan.
Setting an indoor unit address (MAIN/RMC)
Option No. : 0AXXXX-1XXXXX-2XXXXX-3XXXXX
Indoor Unit
1(L) F2
F1
2(N)
4. Assign an indoor unit address by wireless remote controller.
- The initial setting status of indoor unit ADDRESS(MAIN/RMC) is “0A0000-100000-200000-300000”.
When “A”~”F” is entered to SEG5~6, the indoor unit MAIN ADDRESS is not changed.
If you set the SEG 3 as 0, the indoor unit will maintain the previous MAIN ADDRESS even if you input the option value of SEG5~6.
If you set the SEG 9 as 0, the indoor unit will maintain previous RMC ADDRESS even if you input the option value of SEG11~12.
You cannot set SEG11 and SEG12 as F value at the same time.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE Setting Main address 100-digit of indoor
unit address 10-digit of indoor unit The unit digit of an
indoor unit
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 A
0No Main
address
0~9 100-digit 0~9 10-digit 0~9 A unit
digit
1
Main
address
setting
mode
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE
_
Setting RMC address
_
Group channel(*16) Group address
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
1
0No RMC
address
RMC1 0~F RMC2 0~F
1
RMC
address
setting
mode
39
ENGLISH
Setting an indoor unit address and installation option
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power
supply in the indoor unit.
2. The panel(display) should be connected to an indoor unit to receive option.
3. Set the installation option according to the installation condition of an air
conditioner.
- The default setting of an indoor unit installation option is
“020010-100000- 200000-300000”.
- Individual control of a remote controller(SEG20) is the function that controls an
indoor unit individually when there is more than one indoor unit.
Setting an indoor unit installation option (suitable for the condition of each installation location)
Indoor Unit
1(L) F2
F1
2(N)
4. Set the indoor unit option by wireless remote controller.
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
0 2 -
External room
temperature sensor
/ Minimizing fan
operation when
thermostat is o
Central control FAN RPM
compensation
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1Drain pump Hot water heater -EEV Step when
heating stops -
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2External control
External control output
/ External heater On or
O signal
S-Plasma ion Buzzer Number of hours using
lter
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3Individual control of a
remote controller
Heating setting
compensation /
Removing condensated
water in heating mode
EEV Step of
stopped unit during
oil return/defrost
mode
Motion detect sensor -
02 series installation option
1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to ‘USE + 3minute delay’ even if the drain pump is set to 0.
1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using filter(SEG18) will be set to ‘1000hour’ even if the SEG18 is set to
except for 2 or 6.
When setting the option other than above SEG values, the option will be set as “0”.
SEG5 central control option is basically set as 1 (Use), so you don’t need to set the central control option additionally.
However, if the central control is not connected but it doesn’t indicate an error message, you need to set the central control
option as 0 (Disuse) to exclude the indoor unit from the central control.
40
Setting an indoor unit address and installation option
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
02 series installation option(Detailed)
F4
F3
F1 F2
V2
V1
1(L) 2(N)
2
1
HOT
COIL
AC
POWER
OUTDOOR
COMMUNICATION
Wire Remote
Controller
DC 12V
* The output of hot coil terminal is AC 220 V / 230 V
(The same as Indoor Unit’s input Power)
COM1 COM2
(+) L N
(-)
The external output of SEG15 is generated by MIM-B14 connection. (Refer to the manual of MIM-B14.)
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE Use of robot cleaning
Use of external room temperature sensor /
Minimizing fan operation when thermostat
is o
Use of central control FAN RPM compensation
Indication
and Details
Indication Details Indication Details Indication Details Indication
Details
Indication Details Indication Details
Use of
External room
temperature
sensor
Minimizing fan
operation when
thermostat is o
0 2
0Disuse
0Disuse Disuse
0Disuse
0Disuse
1Use Disuse 1
RPM
compensation
1Use 2Disuse Use
(*1)
1Use 2High ceiling
KIT
3Use Use
(*1)
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE Use of drain pump Use of hot water
heater
EEV Step when heating
stops
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
1
0Disuse 0Disuse 0Default value
1Use 1Use
(*2)
1
Noise
decreasing
setting
2
When an
indoor unit
stops, drain
pump will
operate for
3min
2--
3Use
(*2)
The output of hot water heater in SEG9 is generated from the hot coil part of the terminal board in duct models.
41
ENGLISH
Setting an indoor unit address and installation option
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation PAGE Use of external
control
Setting the output of external control /
External heater On/O signal S-Plasma ion Buzzer control Hours of lter usage
Indication and
Details
Indication Details Indication Details Indication
Details
Indication Details Indication Details Indication Details
Setting the
output of
external
control
External heater On/
O signal
2
0 Disuse 0 Thermo on - 0 Disuse 0 Use buzzer 2 1000 Hour
1ON/OFF
control 1 Operation
on -
1Use
1 Disuse buzzer
6 2000 Hour
2OFF
control 2 - Use (*3)
3
Window
ON/OFF
control
3 - Use (*3)
Option SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
Explanation PAGE Individual control of a
remote controller
Heating setting compensation /
Removing condensated water in heating mode
EEV Step of stopped
unit during oil return/
defrost mode
Motion detect sensor -
Indication and
Details
Indication Details Indication Details Indication
Details
Indication Details Indication Details
Heating Setting
Compensation
Removing Condensated
Water in Heating Mode
3
0 or 1 channel 1 0 Default (*4) Disuse 0Default
value
0 Disuse
1Turn out in 30min.
without motion
2 channel 2 1 2 °C Disuse
1
Oil return
or Noise
decreasing
in defrost
mode
2Turn out in 60min.
without motion
3 channel 3 2 5 °C Disuse 3
Turn out in
120min. without
motion
4 channel 4
3 Default (*4) Use (*5) 4
Turn out in
180min. without
motion
4 2 °C Use (*5) 5
Turn out in 30min.
without motion
or *advanced
function
55 °C (9 °F Use (*5)
6
Turn out in 60min.
without motion
or *advanced
function
7
Turn out in
120min. without
motion or *ad-
vanced function
8
Turn out in
180min. without
motion or *ad-
vanced function
42
Setting an indoor unit address and installation option
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
0 5
Use of Auto Change Over
for HR only in Auto mode
(When setting SEG3)
Standard heating temp.
Oset
(When setting SEG3)
Standard cooling temp.
Oset
(When setting SEG3)
Standard for mode change
Heating → Cooling
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1
(When setting SEG3)
Standard for mode change
Cooling → Heating
(When setting SEG3)
Time required for mode
change
Compensation option
for Long pipe
or height dierence
between indoor units
- -
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2 - - - -
Control variables when using
hot water / external heater
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3 - - - - -
05 series installation option
* Advanced function: Controlling cooling/heating current or power saving with motion detect.
(*1) Minimizing fan operation when thermostat is o
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
(*2) 1: Fan is turned on continually when the hot water heater is turned on,
3: Fan is turned o when the hot water heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option,install the Mode Select switch(MCM-C200) on the outdoor unit and x it as cool mode.
(*3) When the following 2 or 3 is used as external heater On/O signal, the signal for monitoring external contact control will not be output.
2: Fan is turned on continually when the external heater is turned on,
3: Fan is turned o when the external heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option,install the Mode Select switch(MCM-C200) on the outdoor unit and x it as cool mode.
· If Fan is set to o for cooling only indoor unit by setting the SEG9=3 or SEG15=3, you need to use an external sensor or wired remote
controller sensor to detect indoor temperature exactly.
(*4) Default setting value
- 4Way Cassette, Mini 4Way Cassette: 5 °C
- Other indoor units: 2 °C
(*5) This function can be applied to 4 Way Cassette and Mini 4 Way Cassette only. If the air conditioner operates the heating mode immediately after
nishing the cooling mode, the condensated water in the drain pan becomes water vapor by the heat of the indoor unit heat exchanger. Since
the water vapor might be condensed on the indoor unit, which may fall into a living space, use this function to get rid of the water vapor out of
the indoor unit by operating the fan (for maximum 20 minutes) even when the indoor unit is turned o after cooling mode is turned to heating
mode .
Air Flow
Suction side Discharge side
Electronic heater should
not be installed.
• Do not install the electronic heater in the ow channel of the indoor unit fan.
Duct Indoor unit
43
ENGLISH
Setting an indoor unit address and installation option
Option No. : 05XXXX-1XXXXX-2XXXXX-3XXXXX
05 series installation option(Detailed)
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE
Use of Auto Change
Over for HR only in
Auto mode
(When setting SEG3)
Standard heating temp.
Oset
(When setting SEG3)
Standard cooling temp.
Oset
(When setting SEG3)
Standard for mode
change
Heating
→
Cooling
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 5
0
Follow
product
option
0 0 0 0 0 1
1
Use Auto
Change
Over for
HR only
10.5 10.5 11.5
2 1 2 1 2 2
31.5 31.5 32.5
4 2 4 2 4 3
52.5 52.5 53.5
6 3 6 3 6 4
73.5 73.5 74.5
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE
(When setting SEG3)
Standard for
mode change
Cooling
→
Heating
(When setting SEG3)
Time required
for mode change
Compensation option
for Long pipe or height
diference between
indoor units
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
1
0 1 0 5 min. 0Use default
value
11.5 17 min.
1
1) Height
difference1)
is more
than 30m
or
2) Distance2)
is longer
than 110m
2 2 2 9 min.
32.5 311 min.
4 3 4 13 min.
2
1) Height
difference1)
is 15~30m
or
2) Distance2)
is 50~110m
53.5 515 min.
6 4 6 20 min.
74.5 730 min.
44
(*1) Height dierence : The dierence of the height between the corresponding indoor uint and the indoor unit installed at the lowest place.
For example, When the indoor unit is installed 40m higher than the indoor unit installed at the lowest place, select the option
"1".
(*2) Distance : The dierence between the pipe length of the indoor unit istalled at farthest place from an outdoor unit and the pipe length of the
corresponding indoor unit from an outdoor unit.
For example, when the farthest pipe length is 100m and the corresponding indoor unit is 40m away from an outdoor unit, select the
option "2".
(100 - 40 = 60m)
(*3) Heater operation when the SEG9 of 02 series installation option is set to using hot water heater or when SEG15 is set to using external heater
e.g. 1) Setting 02 series SEG9 =”1” / Setting 05 series SEG18 = “0”: Hot water heater is turned on at the same time as the heating thermostat is
on, and turned o when the heating thermostat is o.
e.g. 2) Setting 02 series SEG15 =”2” / Setting 05 series SEG18 =”A”:
Room temp. ≤ set temp. + f(heating compensation temp.)
- External heater is turned on when the temperature is maintained as 4.5 °C for 10 minutes.
Room temp. > set temp. + f(heating compensation temp.)
- External heater is turned o when the temperature is maintained as 4.5 °C + 1 °C (1 °C is the Hysteresis for On/O selection.)
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
(*3)
Explanation Control variables when using hot water / external heater
Indication and
Details
Indication Details
Set temp. for heater On/O
Delay time for heater On
2
0At the same time as thermo on No delay
1At the same time as thermo on 10 minutes
2At the same time as thermo on 20 minutes
31.5 °C No delay
41.5 °C 10 minutes
51.5 °C 20 minutes
63.0 °C No delay
73.0 °C 10 minutes
83.0 °C 20 minutes
94.5 °C No delay
A4.5 °C 10 minutes
B4.5 °C 20 minutes
C6.0 °C No delay
D6.0 °C 10 minutes
E6.0 °C 20 minutes
Setting an indoor unit address and installation option
45
ENGLISH
Setting an indoor unit address and installation option
Changing a particular option
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE The option mode
you want to change
The tens’ digit of an
option SEG you will
change
The unit digit of an
option SEG you will
change
The changed value
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 D Option
mode 1~6 Tens’ digit
of SEG 0~9 Unit digit of
SEG 0~9
The
changed
value
0~F
You can change each digit of set option.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE The option mode
you want to change
The tens’ digit of an
option SEG you will
change
The unit digit of an
option SEG you will
change
The changed value
Indication 0 D 2 1 7 1
• Whenchangingadigitofanindoorunitaddresssettingoption,settheSEG3as‘A’.
• Whenchangingadigitofindoorunitinstallationoption,settheSEG3as‘2’.
Ex) When setting the ‘buzzer control’ into disuse status.
Note
SEG 3, 4, 5, 6, 8, 9 additional information
When the SEG 3 is set as "1" and follow Auto Change Over for HR only operation, it will operate as follows.
Cooling/Heating mode can be changed when Thermo O status is maintained during the time with SEG9.
A : Set with SEG4(˚C)
B : Set with SEG5(˚C)
C : Set with SEG6(˚C)
D : Set with SEG8(˚C)
Cooling Thermo O
Heating Thermo O
Cooling Thermo On
Heating Thermo On
B C
D
Ts
A
c
a
Temp.
d
b
Standard temp.
for Heating
Standard temp.
for Cooling
Standard temp. for
Heating
→
Cooling
Standard temp.
for Cooling
→
Heating
Set temp.
for Auto mode
QUESTIONS OR COMMENTS?
DB68-03631A-13
SAMSUNG ELECTRONICS CO.,LTD.
No.501 Suhong East Road,Suzhou Industrial Park,Jiangsu Province,P.R.China
SUZHOU SAMSUNG ELECTRONICS CO.,LTD EXPORT
No.218 Jiepu Road,Suzhou Industry Park,Jiangsu Province,P.R.China
Samsung Electronics
Service Department
PO Box 12987, Blackrock, Co. Dublin. Ireland
or
Blackbushe Business Park, Yateley, GU46 6GG. UK
COUNTRY CALL
OR VISIT US ONLINE AT
AUSTRIA
0800-SAMSUNG (0800-7267864)
[Only for KNOX customers] 0800
400848
[Only for Premium HA] 0800-366661
[Only for Dealers] 0810-112233
[Only for E-Store] 0800 100 232
www.samsung.com/at/support
BELGIUM 02-201-24-18
www.samsung.com/be/support
(Dutch)
www.samsung.com/be_fr/support
(French)
BOSNIA 055 233 999
www.samsung.com/support
BULGARIA
*3000 Цена в мрежата
0800 111 31 , Безплатна телефонна
линия
www.samsung.com/bg/support
CROATIA 072 726 786
www.samsung.com/hr/support
CZECH 800 - SAMSUNG (800-726786)
www.samsung.com/cz/support
DENMARK 707 019 70
www.samsung.com/dk/support
FINLAND 030-6227 515
www.samsung.com//support
FRANCE 01 48 63 00 00
www.samsung.com/fr/support
GERMANY 06196 77 555 66 *HHP
06196 77 555 77 *OTH
www.samsung.com/de/support
CYPRUS 8009 4000 only from landline, toll free
www.samsung.com/gr/support
GREECE
80111-SAMSUNG (80111 726 7864) only from
land line
(+30) 210 6897691 from mobile and land line
HUNGARY 0680SAMSUNG (0680-726-7864)
www.samsung.com/hu/support
ITALIA 800-SAMSUNG (800.7267864)
www.samsung.com/it/support
LUXEMBURG
261 03 710
www.samsung.com/support
MONTENEGRO
020 405 888
www.samsung.com/support
SLOVENIA
080 697 267 (brezplačna številka)
www.samsung.com/si/support
NETHERLANDS
088 90 90 100
www.samsung.com/nl/support
NORWAY 21629099
www.samsung.com/no/support
POLAND
801-172-678* lub +48 22 607-93-33*
Dedykowana infolinia do obsługi zapytań
dotyczńcych telefonów komórkowych:
801-672-678* lub +48 22 607-93-33*
* (opłata według taryfy operatora)
www.samsung.com/pl/support
PORTUGAL 808 20 7267
www.samsung.com/pt/support
ROMANIA
*8000 (apel in retea)
08008-726-78-64 (08008-SAMSUNG) Apel
GRATUIT
www.samsung.com/ro/support
SERBIA 011 321 6899
www.samsung.com/rs/support
SLOVAKIA 0800 - SAMSUNG(0800-726 786)
www.samsung.com/sk/support
SPAIN 0034902172678
[HHP] 0034902167267
www.samsung.com/es/support
SWEDEN 0771 726 786
www.samsung.com/se/support
SWITZERLAND
0848 726 78 64 (0800-SAMSUNG)
www.samsung.com/ch/support
(German)
www.samsung.com/ch_fr/support
(French)
U.K 0330 SAMSUNG (7267864)
www.samsung.com/uk/support
IRELAND
(EIRE) 0818 717100
www.samsung.com/ie/support
LITHUANIA 8-800-77777
www.samsung.com/lt/support
LATVIA 8000-7267
www.samsung.com/lv/support
ESTONIA 800-7267
www.samsung.com/ee/support
RUSSIA
8-800-555-55-55 (VIP care 8-800-555-
55-88)
www.samsung.com/ru/support
GEORGIA
0-800-555-555
www.samsung.com/support
ARMENIA
0-800-05-555
www.samsung.com/support
AZERBAIJAN
0-88-555-55-55
www.samsung.com/support
KAZAKHSTAN
8-10-800-500-55-500(GSM: 7799, VIP care 7700)
www.samsung.com/support
UZBEKISTAN
00-800-500-55-500 (GSM: 7799)
www.samsung.com/support
KYRGYZSTAN
00-800-500-55-500 (GSM: 9977)
www.samsung.com/kz_ru/support
TAJIKISTAN
8-10-800-500-55-500 (GSM: 8888)
www.samsung.com/support
MONGOLIA
1800-25-55
www.samsung.com/support
BELARUS 810-800-500-55-500
www.samsung.com/support
UKRAINE
0-800-502-000
www.samsung.com/ua/support
(Ukrainian)
www.samsung.com/ua_ru/support
(Russian)
COUNTRY CALL
OR VISIT US ONLINE AT
MOLDOVA
0-800-614-40
www.samsung.com/support
U.A.E
800-SAMSUNG (800 - 726 7864)
www.samsung.com/ae/support (English)
www.samsung.com/ae_ar/support (Arabic)
OMAN
800-SAM CS (800-72627)
KUWAIT
183-CALL (183-2255)
BAHRAIN
8000-GSAM (8000-4726)
QATAR 800-CALL (800-2255)
EGYPT
08000-726786
16580
www.samsung.com/eg/support
ALGERIA 3004
www.samsung.com/n_africa/support
PAKISTAN 0800-Samsung (72678)
www.samsung.com/pk/support
TUNISIA 80 1000 12
www.samsung.com/n_africa/support
JORDAN
0800-22273
06 5777444
www.samsung.com/Levant/support
SYRIA 962 5777444
Lebanon 1299
Iraq 80010080
IRAN
021-8255 [CE]
021-42132 [HHP]
www.samsung.com/iran/support
MOROCCO
080 100 2255
www.samsung.com/n_africa/support
SAUDI ARABIA
(+966) 8002474357 (800 24/7 HELP)
www.samsung.com/sa_en/
support(English)
www.samsung.com/sa/support(Arabic)
TURKEY 444 77 11
www.samsung.com/tr/support
Israel *6963
www.samsung.com/il/support/
ARGENTINA 0800-555-SAMSUNG(7267)
www.samsung.com/ar
URUGUAY 0800-SAMS(7267)
www.samsung.com/uy
PARAGUAY 0800-11-SAMS(7267)
www.samsung.com/py
BRAZIL
0800-124-421 (Demais cidades e regiões)
4004-0000 (Capitais e grandes centros)
www.samsung.com/br/support
CHILE 800-SAMSUNG(726-7864)
[HHP] 02-24828200 www.samsung.com/cl/support
BOLIVIA 800-10-7260 www.samsung.com/cl/support
COLOMBIA
Bogotá en el 600 12 72
Sin costo en todo el pais 01 8000 112 112
Y desde tu celular #726
www.samsung.com/co/support
COSTA RICA 00-800-1-SAMSUNG (726-7864)
www.samsung.com/latin/support (Spanish)
www.samsung.com/latin_en/support
(English)
DOMINICAN
REPUBLIC 1-809-200-7264
ECUADOR 1-800-SAMSUNG (72-6786)
EL SALVADOR 8000-SAMSUNG (726-7864)
GUATEMALA 1-800-299-0033
HONDURAS 800-2791-9111
JAMAICA 1-800-SAMSUNG (726-7864)
www.samsung.com/latin_en/support
(English)
MEXICO 01-800-SAMSUNG(726-7864) www.samsung.com/mx/
support
NICARAGUA 001-800-5077267
www.samsung.com/latin/support (Spanish)
www.samsung.com/latin_en/support
(English)
PANAMA 800-0101
PUERTO RICO 1-800-682-3180
TRINIDAD &
TOBAGO
1-800-SAMSUNG(726-7864)
PERU 080077708 Desde teléfonos fijos,
públicos o celulares
www.samsung.com/pe/support
VENEZUELA 0-800-SAMSUNG (726-7864)
www.samsung.com/latin/support
(Spanish)
www.samsung.com/latin_en/support
(English)
AUSTRALIA 1300 362 603 (Other)
1300 425 299 (HHP)
www.samsung.com/au/support
PHILIPPINES
Only for HHP PRODUCT :
02-422-2177 [ Standard Landline ]
OTH PRODUCT :
1-800-10-726-7864 [ PLDT Toll Free ]
1-800-8-726-7864 [ Globe Landline and
Mobile ]
02-422-2111 [ Standard Landline ]
www.samsung.com/ph/support
SINGAPORE
1800 7267864 | 1800-SAMSUNG (Other)
1800 4252997 | 1800-GALAXYS (HHP)
www.samsung.com/sg/support
Air Conditioner
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
Console Type Series
Floor : AMNJD