Samsung AM071FNMDEH User Manual
Displayed below is the user manual for AM071FNMDEH by Samsung which is a product in the Split-System Air Conditioners category. This manual has pages.
Related Manuals
02_ safety information
safety information
To prevent electric shock, disconnect the power before servicing, cleaning, and installing
the air conditioner.
SAFETY INFORMATION
Before using your new air conditioner, please read this manual thoroughly to ensure that
you know how to safely and efficiently operate the extensive features and functions of
your new appliance.
Because the following operating instructions cover various models, the characteristics
of your air conditioner may differ slightly from those described in this manual. If you have
any questions, call your nearest contact center or find help and information online at
www.samsung.com.
Important safety symbols and precautions:
WARNING
Hazards or unsafe practices that may result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor
personal injury or property damage.
CAUTION
To reduce the risk of fire, explosion, electric shock, or
personal injury when using your air conditioner, follow
these basic safety precautions:
Do NOT attempt.
Do NOT disassemble.
Do NOT touch.
Follow directions carefully.
Unplug the power plug from the wall socket.
Make sure the machine is grounded to prevent electric
shock.
Call the contact center for help.
Note.
These warning signs are here to prevent injury to you and others.
Please follow them carefully.
After reading this section, keep it in a safe place for future
reference.
safety information _03
ENGLISH
SEVERE WARNING SIGNS
Do not place the air conditioner near hazardous substances or
equipment that releases free flames to avoid fire, explosions or injuries.
• Potential risk of fire hazard or explosion.
Do not install the outdoor unit at an unstable place or elevated surface
where there is potential risk of falling.
• If the outdoor unit falls, it may cause personal injury or loss of property.
Failure or damage may occur if any changes or modification that is not
stated in the installation manual was performed. In this case, user will
be responsible for the repair expenses.
Install the air conditioner away from direct exposure to sunlight,
heating apparatus, and humid places.
• Hang curtains on windows to boost cooling efficiency and to avoid the
risk of electric shock.
Do not cut the power plug and connect to a different power cable.
Do not yank the power cable and touch the power plug with hands.
• Potential risk of fire or electric shock.
Never use a damaged or dusted power plug, power cable, or loosened
power receptacle.
• Potential risk of fire or electric shock.
Install an exclusive circuit breaker and short-circuit breaker for the air
conditioner.
• Potential risk of electric shock or fire.
Do not insert anything such as fingers or branches into the air
conditioner vents while the air conditioner is running.
• Keep the children away from the air conditioner to prevent them from
putting their finger on the air conditioner. Potential risk of personal injury.
Ensure no water gets into the air conditioner.
• Potential risk or electric shock.
• If the water gets into the air conditioner, stop and unplug the power
source immediately.
Turn off the air conditioner using the provided remote control or control
accessory (if provided). Do not unplug to turn off the unit (unless there
is an immediate danger).
Do not run the air conditioner for an extended period of time in a room
with the door closed or with babies, elderly or disabled people.
• Open the door or windows to ventilate your room at least once an hour to
prevent oxygen shortage.
The air conditioner is composed of moving parts. Keep children away
from the unit to avoid physical injury.
WARNING
04_ safety information
safety information
Make sure that children take precautions against access to the air
conditioner and they do not play with the unit.
Do not clean the interior of air conditioner on your own.
• You may damage the parts which can cause electric shock or fire
• Consult contact center for cleaning the interior of the air conditioner.
Do not Connect the air conditioner with heating apparatus or attempt to
disassemble,remodel or repair it yourself.
• Potential risk of malfunction, electric shock or fire. If repairs are needed,
consult the contact center.
Consult the place of purchase or contact to install,reinstall or
disassemble the aire conditioner.
• Improper installation carries a risk of unit malfunction, water leakage, electric
shock or fire.
• If installing in specialty areas, such as a factory complex or saline coastal
area, consult the place of purchase or contact center for specific installation
details.
• The units must be installed according to distances declared, in order to
permit accessibility from each side, either to guarantee correct operation of
maintenance or repairing products. The unit’s parts must be reachable and
removable completely under safety condition (for people or things).
Consult a dealer regarding the appropriate measures to prevent the
allowable concentration from being exceeded.
• If the refrigerant leaks, and cause the concentration limit to be exceeded,
hazards due to lack of oxygen in the room may result.
If the indoor unit gets wet, turn the power off immediately and call your
nearest contact center.
• Potential risk of fire or electric shock.
Always make sure that the power supply is compliant with current safety
standards. Always install the air conditioner in compliance with current
local safety standards.
Verify that the voltage and frequency of the power supply comply with
the specifications and that the installed power is sufficient to ensure
the operation of any other domestic appliance connected to the same
electric lines.
Use a rated circuit breaker only.
• Never use steel wires or copper wires as a circuit breaker. It may cause fire
or unit malfunctions.
Do not put undue stress or place heavy object on the power cable.
Do not bend the power cable excessively.
• Potential risk of fire or electric shock.
To protect the product from water and possible shock, you should keep
the power cable and the connection cord of the indoor and outdoor units
in the protection tube.
When opening or closing the front panel, use a stable stool and watch
your steps carefully.
safety information _05
ENGLISH
Disconnect the air conditioner from power supply before it is repaired or
disassembled.
Clean the air conditioner after the inner fan stops operating.
• Potential risk of injury or electric shock.
SEVERE WARNING SIGNS (CONT’D)
Use a receptacle that has a ground terminal. The receptacle must be
used exclusively for the air conditioner.
• Improper electrical grounding may cause electric shock or fire.
Be sure to ground the unit. Do not connect the ground wire to gas or
water pipes, lighting rods, or telephone grounding lines.
• If the unit is not properly grounded, electric shock may result.
If you smell burning plastic, hear strange sounds, or see smoke coming
from the unit, unplug the air conditioner immediately and call a contact
center.
• Potential risk of fire or electric shock.
CAUTION SIGNS
Do not block or place items in front of the air conditioner. Do not step,
hang onto, or place heavy items on the air conditioner.
• Potential risk of personal injury.
If failure or damage occurs on the conditions of improper use not
followed by the installation manual, there will be an extra labor charge
for installing and construction.
• Potential risk of malfunction, electric shock or fire if repairs or installations
are attempted by a non-qualified service technician.
Do not spray flammable gases such as insecticide near the air
conditioner.
• Potential risk of electric shock, fire or unit malfunction.
Do not open the front grille during operation.
• Potential risk of electric shock or unit malfunction.
Cool air should not flow directly towards people, pets, and plants.
• It is harmful to your health, pets, and plants.
Do not drink drain water coming out of the air conditioner.
• Potential risk of health hazard.
Do not allow children to climb on the air conditioner.
Do not use the air conditioner as a cooling precision instrument for
food, pets, plants, cosmetics or machinery.
Do not pull or give excessive shock to the air conditioner.
• Potential risk of fire, or unit malfunction and there are risk of personal
injury because unit may fall down.
Do not spray water directly on the air conditioner or use benzene,
thinner or alcohol to clean the surface of the unit.
• Potential risk of electric shock or fire.
• Potential risk of damage to the air conditioner.
Do not place any objects, especially containers with liquid.
WARNING
CAUTION
06_ safety information
safety information
Do not touch the pipe connected to the air conditioner.
Install the indoor unit (receiver) in a place far away from the lighting
equipment of the ballast.
• If you use the wireless remote control, reception error may occur due to
the ballast of the lighting apparatus.
Install the outdoor unit where operating noise and vibration will not
disturb your neighbor and in a well-ventilated area with no obstacle.
• Potential risk of malfunction.
• Operating noise may disturb your neighbor.
Make sure that there are no obstacles or covers that block the air
conditioner.
Allow sufficient space for air circulation.
• Insufficient ventilation may result in poor performance.
If the power cable is damaged, the manufacturer or a qualified service
technician must replace it.
If a power outage occurs while the air conditioner is working, turn off
the power source immediately.
Max current is measured according to IEC standard for safety and
current is measured according to ISO standard for energy efficiency.
Check for damage on delivery. If damaged, do not install the air
conditioner and call the place of purchase immediately.
Keep indoor temperatures stable and not extremely cold, especially
where there are children, elderly or disabled people.
The packaging material and used batteries of the remote controller
(optional) must be disposed of in accordance with the national
standards.
The refrigerant used in the air conditioner must be treated as chemical
waste. Dispose the refrigerant following national standards.
Have a qualified service technician install the air conditioner and
perform a trial operation.
Firmly connect the drain hose to the air conditioner for proper water
drainage.
Check for damages on the outdoor unit installation pad at least once a year.
• Potential risk of personal injury or property loss.
When using a wireless remote control, the distance should not be more
than 7 meters from the air conditioner.
If the remote control is not used for a long period of time, remove the
batteries to prevent leakage of electrolyte.
When cleaning the outdoor unit, touch the heat exchanger radiator fins
with extreme care.
• Wearing thick gloves can protect your hands.
Make sure that the condensed water dripping from the drain hose runs
out properly and safely.
safety information _07
ENGLISH
The appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety: Young children should be supervised to ensure that they
do not play with the appliance.
CAUTION SIGNS (CONT’D)
Inspect the condition, electric connections, pipes and external case of
the air conditioner regularly by a qualified service technician.
Do not open doors and windows in the room being cooled during
operation unless necessary.
Do not block the air conditioner vents. If objects block the air flow, it
may cause unit malfunction or poor performance.
Make sure there are no obstacles under the indoor unit.
• Potential risk of fire or loss of property.
The air conditioner should be used only for the applications for which
it has been designed: the indoor unit is not suitable to be installed in
areas used for laundry.
Our units must be installed in compliance with the spaces indicated
in the installation manual to ensure either accessibility from both
sides or ability to perform routine maintenance and repairs. The units’
components must be accessible and that can be disassembled in
conditions of complete safety either for people or things.
For this reason, where it is not observed as indicated into the
Installation Manual, the cost necessary to reach and repair the unit
(in safety, as required by current regulations in force) with slings,
trucks, scaffolding or any other means of elevation won’t be considered
in-warranty and charged to end user.
For use in Europe : This appliance can be used by children aged from 8
years and above and persons with reduced physical,sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
Ensure the off-on and protection switches are properly installed.
Do not use the air conditioner if damaged. If problems occur,
immediately stop operation and disconnect the plug from the power
supply.
If the air conditioner will not be used for an extended period of time
(for example, over several months), unplug the power from the wall.
Call the place of purchase or a contact center if repairs are needed.
• Potential risk of fire or electric shock if disassembly or repairs are
attempted by a non-qualified service technician.
If you smell burning plastic, hear strange sounds, or see smoke coming
from the unit, unplug the air conditioner immediately and call a contact
center.
• Potential risk of fire or electric shock.
CAUTION
08_ contents
contents
VIEWING YOUR AIR CONDITIONER
9
9 Slim duct type
9 MA/HSP duct type
USING YOUR AIR CONDITIONER
10
10 Tips on using your air conditioner
CLEANING AND MAINTAINING
THE AIR CONDITIONER
11
11 Cleaning the filter
11 Slim duct type
12 MA/HSP duct type
13 Maintaining your air conditioner
13 Periodical checks
14 Internal protections via the unit control
system
APPENDIX
15
15 Troubleshooting
16 Operation ranges
INSTALLING YOUR
AIR CONDITIONER
17
17 Installation part
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB
cable) should not be disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or
human health from uncontrolled waste disposal, please separate these items from other types of waste and recycle them responsibly to pro-
mote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and
how they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic
accessories should not be mixed with other commercial wastes for disposal.
For information on Samsung’s environmental commitments and product-specific regulatory obligations, e.g. REACH, WEEE, Batteries, visit:
www.samsung.com/uk/aboutsamsung/sustainability/environment/our-commitment/data/
viewing your air conditioner _9
ENGLISH
viewing your air conditioner
Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air
conditioner and stay cool or warm with optimal efficiency.
Please read the user manual to get started and to make the best use of the air conditioner.
SLIM DUCT TYPE
MA DUCT TYPE
Your air conditioner may look slightly different from the illustration shown above depending
on your model.
Air intake
Air outlet
Ceiling
Air filter (the return air side)
Air intake
Air outlet
Ceiling
Air filter (the return air side)
HSP DUCT TYPE
Air intake
Air outlet
Ceiling
10_ using your air conditioner
using your air conditioner
TIPS ON USING YOUR AIR CONDITIONER
Here are some tips that you would follow when using your air conditioner.
TOPIC RECOMMENDATION
Cooling • If current outside temperatures are much higher than the selected indoor
temperature, it may take time to bring the inner temperature to the desired
coolness.
• Avoid drastically turning down the temperature.
Energy is wasted and the room does not cool faster.
Heating • Since the air conditioner heats the room by taking heat energy
from outdoor air, the heating capacity may decrease when outdoor
temperatures are extremely low. If you feel the air conditioner insufficiently
heats, using an additional heating appliance in combination with the air
conditioner is recommended.
Frost & De-ice • When the air conditioner runs in Heat mode, due to temperature difference
between the unit and the outside air, frost will form.
If this happens:
- The air conditioner stops heating.
- The air conditioner will operate automatically in De-ice mode for
10 minutes.
- The steam produced on the outdoor unit in De-ice mode is safe.
No intervention is required; after about 10 minutes, the air conditioner
operates again normally.
The unit will not operate when it starts to de-ice.
Fan • Fan may not operate for about 3~5 minutes at the beginning to prevent
any cold blasts while the air conditioner is warming up.
High indoor/outdoor
temperatures
• If both indoor and outdoor temperatures are high and the air conditioner is
running in Heat mode, the outdoor unit’s fan and compressor may stop at
times. This is normal; wait until the air conditioner turns on again.
Power failure • If a power failure occurs during the operation of the air conditioner, the
operating immediately stops and unit will be off. When power returns, the
air conditioner will run automatically.
Protection mechanism • If the air conditioner has just been turned on after operation stops or being
plugged in, cool/warm air does not come out for 3 minutes to protect the
compressor of the outdoor unit.
cleaning and maintaining the air conditioner _11
ENGLISH
cleaning and maintaining the
air conditioner
For the best performance from your air conditioner, clean it periodically. When cleaning, make sure to
unplug from the unit for user’s safety.
CLEANING THE FILTER
When cleaning the filter, make sure to unplug the power from the unit. Washable foam based Air filter
captures large particles from the air. The filter is cleaned with a vacuum or by hand washing.
Slim duct type
1. Slide out the Air filter on the rear side panel to the right side.
2. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
• For best conditions, repeat every two weeks.
• If the Air filter dries in a confined (or humid) area, odors may generate. If it occurs,
re-clean and dry it in a ventilated area.
3. Insert the Air filter back in its original position.
• The illustration shown above may differ from your depending on your model.
• After cleaning the filter, press the Filter Reset button on the remote control for 2 seconds
to reset the filler schedule. Filter sign indicator will be on for cleaning time.
12_ cleaning and maintaining the air conditioner
cleaning and maintaining the
air conditioner
MA/HSP duct type
1. Slide out the Air filter on the rear side panel to the right side.
2. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with
running water and dry it in a ventilated area.
• For best conditions, repeat every two weeks.
• If the Air filter dries in a confined (or humid) area, odors may generate. If it occurs,
re-clean and dry it in a ventilated area.
3. Insert the Air filter back in its original position.
• The illustration shown above may differ from your depending on your model.
• After cleaning the filter, press the Filter Reset button on the remote control for 2 seconds
to reset the filler schedule. Filter sign indicator will be on for cleaning time.
cleaning and maintaining the air conditioner _13
ENGLISH
MAINTAINING YOUR AIR CONDITIONER
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in
best condition.
1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect
the power plug. There may be internal damage if moisture is left in components.
2. Before using the air conditioner again, dry the inner components of the air conditioner again
by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated
from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type Description Monthly Every 4
months
Once a
year
Indoor unit
Clean the air filter (1)
Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the condensate drain pipe (2)
Replace the remote control batteries (1)
Outdoor unit
Clean the heat exchanger on the outside of
the unit (2)
Clean the heat exchanger on the inside of
the unit (2)
Clean the electric components with jets of
air (2)
Verify that all the electric components are
firmly tightened (2)
Clean the fan (2)
Verify that all the fan assembly is firmly
tightened (2)
Clean the condensate drain pan (2)
The checks and maintenance operations described are essential to guarantee the
efficiency of the air conditioner. The frequency of these operations varies according to the
characteristics of the area, the amount of dust, etc.
(1) The described operations should be performed more frequently if the area of installation
is very dusty.
(2) These operations must always be performed by qualified personnel. For more detailed
information, see the Installation Manual.
14_ cleaning and maintaining the air conditioner
cleaning and maintaining the
air conditioner
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
Type Description
Against cold air
The internal fan will be off to against cold air when the heat pump is
heating.
De-ice cycle
The internal fan will be off to against cold air when the heat pump is
heating.
Anti-protection of
internal battery
The compressor will be off to protect internal battery when the air
conditioner operates in Cool mode.
Protect compressor
The air conditioner does not start operating immediately to protect the
compressor of the outdoor unit after it has been started.
If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from
an outdoor unit that may have deposited at low temperatures.
The internal fan is switched off automatically and restarted only after the de-ice cycle is
completed.
appendix _15
ENGLISH
appendix
TROUBLESHOOTING
Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary
expenses.
PROBLEM SOLUTION
The air conditioner does not
operate immediately after it
has been restarted.
• Because of the protective mechanism, the appliance does not start operating
immediately to keep the unit from overloading.
The air conditioner will start in 3 minutes.
The air conditioner does not
work at all.
• Check that the power plug is properly connected. Insert the power plug into the
wall socket correctly.
• Check if the circuit breaker is switched off.
• Check if there is a power failure.
• Check your fuse. Make sure it is not blown out.
The temperature does not
change.
• Check if you selected Fan mode.
Press the Mode button on the remote control to select another mode.
The cool (warm) air does
not come out of the air
conditioner.
• Check if the set temperature is higher (lower) than the current temperature. Press
the Temperature button on the remote control to change the set temperature.
Press the Temperature button to decrease or increase the temperature.
• Check if the air filter is blocked by dirt. Clean the air filter every two weeks.
• Check if the air conditioner has just been turned on. If so, wait 3 minutes. Cool air
does not come out to protect the compressor of the outdoor unit.
• Check if the air conditioner is installed in a place with a direct exposure to sunlight.
Hang curtains on windows to boost cooling efficiency.
• Check if the cover or any obstacle is not near the outdoor unit.
• Check if the refrigerant pipe is too long.
• Check if the air conditioner is only available in Cool mode.
• Check if the remote control is only available for cooling model.
The fan speed does not
change.
• Check if you selected Auto or Dry mode.
The air conditioner automatically adjusts the fan speed to Auto in Auto/Dry mode.
Timer function does not set. • Check if you press the Power button on the remote control after you have set the time.
Odors permeate in the room
during operation.
• Check if the appliance is running in a smoky area or if there is a smell entering from
outside. Operate the air conditioner in Fan mode or open the windows to air out the
room.
The air conditioner makes a
bubbling sound.
• A bubbling sound may be heard when the refrigerant is circulating through the
compressor. Let the air conditioner operate in a selected mode.
• When you press the Power button on the remote control, noise may be heard from
the drain pump inside the air conditioner.
Water is dripping from the
air flow blades.
• Check if the air conditioner has been cooling for an extended period of time with
the air flow blades pointed downwards. Condensation may generate due to the
difference in temperature.
Remote control is not
working.
• Check if your batteries are depleted.
• Make sure batteries are correctly installed.
• Make sure nothing is blocking your remote control sensor.
• Check that there are strong lighting apparatus near the air conditioner. Strong light
which comes from fluorescent bulbs or neon signs may interrupt the electric waves.
The air conditioner does not
turn on or off with the wired
remote control.
• Check if you set the wired remote control for group control.
The wired remote control
does not operate.
• Check if TEST indicator is displayed on the wired remote control. If so, turn off the
unit and switch off the circuit breaker. Call your nearest contact center.
The indicators of the digital
display flashes.
• Press the Power button on the remote control to turn the unit off and switch the
circuit breaker off. Then, switch it on again.
16_ appendix
appendix
OPERATION RANGES
The table below indicates the temperature and humidity ranges the air conditioner can be operated within.
Refer to the table for efficient use.
MODE OPERATIONAL TEMPERATURE INDOOR HUMIDITY IF OUT OF CONDITIONS
INDOOR OUTDOOR
COOLING 18˚C to 32˚C -5˚C to 48˚C 80% or less
Condensation may occur on
the indoor unit with risk to have
either water blow off or drops on
the floor.
HEATING 27˚C or less -20˚C to 24˚C - Internal protection triggers and
the air conditioner will stop.
DRYING 18˚C to 32˚C -5˚C to 48˚C -
Condensation may occur on
the indoor unit with risk to have
either water blow off or drops on
the floor.
The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below,
the heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.
Model specification (Dimension and weight)
Dimension and weight
Type Model Net dimension
(WxDxH) (mm)
Net weight
(kg) Model Net dimension
(WxDxH) (mm)
Net weight
(kg)
Indoor unit
AM017FNLDEH/EU 700*199*600 19 AM056FNMDEH/EU 900*260*480 29
AM022FNLDEH/EU 700*199*600 19 AM071FNMDEH/EU 900*260*480 29
AM028FNLDEH/EU 700*199*600 19 AM090FNMDEH/EU 1150*480*260 32
AM036FNLDEH/EU 700*199*600 19.5 AM112FNMDEH/EU 1150*320*480 36.5
AM045FNLDEH/EU 900*199*600 24.5 AM128FNMDEH/EU 1200*360*650 48.5
AM056FNLDEH/EU 900*199*600 24.5 AM140FNMDEH/EU 1200*360*650 48.5
AM071FNLDEH/EU 1100*199*600 30 AM112FNHDEH/EU 1200*360*650 57
AM090FNLDEH/EU 1300*295*690 40 AM128FNHDEH/EU 1200*360*650 57
AM112FNLDEH/EU 1300*295*690 40 AM140FNHDEH/EU 1200*360*650 57
AM128FNLDEH/EU 1300*295*690 41.5 AM160KNMDEH/EU 1200*360*650 50
AM140FNLDEH/EU 1300*295*690 41.5 AM017KNLDEH/EU 700*199*440 15.3
AM022FNMDEH/EU 900*199*600 23.5 AM022KNLDEH/EU 700*199*440 15.3
AM028FNMDEH/EU 900*199*600 23.5 AM028KNLDEH/EU 700*199*440 15.3
AM036FNMDEH/EU 900*199*600 23.5 AM036KNLDEH/EU 700*199*440 15.7
AM045FNMDEH/EU 900*260*480 29 AM045KNMDEH/EU 900*260*480 28.5
AM045KNLDEH/EU 900*199*600 25 AM056KNMDEH/EU 900*260*480 28.5
AM056KNLDEH/EU 900*199*600 25 AM071KNMDEH/EU 900*260*480 28.5
AM071KNLDEH/EU 1100*199*600 30.5 AM090KNMDEH/EU 1150*260*480 32.5
AM090KNLDEH/EU 1300*295*690 40.5 AM112KNMDEH/EU 1150*320*480 36
AM112KNLDEH/EU 1300*295*690 40.5 AM128KNMDEH/EU 1200*360*650 49
AM128KNLDEH/EU 1300*295*690 42 AM140KNMDEH/EU 1200*360*650 49
AM140KNLDEH/EU 1300*295*690 42 AM160KNHDEH1EU 1200*360*650 50.5
AM022KNMDEH/EU 900*199*600 24 AM036KNMDEH/EU 900*199*600 24
AM028KNMDEH/EU 900*199*600 24 AM045MNLDEH/EU 900*440*199 18.9
AM056MNLDEH/EU 900*440*199 18.9 AM071MNLDEH/EU 1100*440*199 22.3
installing your air conditioner _17
ENGLISH
Indoor Unit Installation
It is recommended to install the Y- joint before installing the
indoor unit.
1. Place the pattern sheet on the ceiling at the spot where you
want to install the indoor unit.
Since the diagram is made of paper, it may
shrink or stretch slightly due to temperature or
humidity. For this reason, before drilling the holes
maintain the correct dimensions between the
markings.
Pattern sheet is supplied depending on the
model type.
Note
2. Insert bolt anchors, use existing ceiling supports or
construct a suitable support as shown in figure.
3. Install the suspension bolts depending on the ceiling type.
Ensure that the ceiling is strong enough to
support the weight of the indoor unit.
Before hanging the unit, test the strength
of each attached suspension bolt.
If the length of suspension bolt is more than
1.5m, it is required to prevent vibration.
If this is not possible, create an opening on
the false ceiling in order to be able to use it
to perform the required operations on the
indoor unit.
4. Screw eight nuts to the suspension bolts making space for
hanging the indoor unit.
You must install the suspension bolts more than
four when installing the indoor unit.
5. Hang the indoor unit to the suspension bolts between two nuts.
Piping must be laid and connected inside the ceiling
when suspending the unit. If the ceiling is already con-
structed, lay the piping into position for connection to
the unit before placing the unit inside the ceiling.
Note
Concrete
Suspension bolt(Φ9.52 or M10)
Hole in anchor
Hole in plug
Insert
Ceiling support
6. Screw the nuts to suspend the unit.
7. Adjust level of the unit by using measurement plate for all 4 sides.
For proper drainage of condensate, give a
10mm(3mm) slant to the left or right side of the
unit which will be connected with the drain hose,
as shown in the figure. Make a tilt when you wish to
install the drain pump, too.
Note
Performing Leak Test & Insulation
LEAK TEST WITH NITROGEN(before opening valves)
In order to detect basic refrigerant leaks, before recreating the
vacuum and recirculating the R410A, it’s responsible of installer
to pressurize the whole system with nitrogen(using a pressure
regulator) at a pressure above 4.1MPa(gauge).
LEAK TEST WITH R410A(after opening valves)
Before opening valves, discharge all the nitrogen into the
system and create vacuum. After opening valves check leaks
using a leak detector for refrigerant R410A.
Leak test
Rubber
1. To avoid condensation problems, place T13.0 or thicker
Acrylonitrile Butadien Rubber separately around each
refrigerant pipe.
Always make the seam of pipes face upwards.
Note
Once you have checked that there are no leaks in the system,
you can insulate the piping and hose.
Insulation
No gap
NBR(T13.0 or thicker)
Installation Part
g AMNLD: 3mm
AM022/028/036NMD: 3mm
AMNMD / AMNHD: 10mm
Drain hose port
10mm(3mm)
AMNLD /
AM022/028/036NMD
Leak check
AM NMD / AM NHD
Leak check
Noise will increase 3~6 dB(A)
when the air flow enters from
the bottom side (Only for
Slim Duct/Home Duct Type
product). Air Flow
CAUTION
CAUTION
CAUTION
AM MNLEH
CAUTION
Discharge all the nitrogen to create a vacuum and
charge the system.
18_ installing your air conditioner
2. Wind insulating tape around the pipes and drain hose
avoiding to compress the insulation too much.
3. Finish wrapping insulating tape around the rest of the
pipes leading to the outdoor unit.
4. The pipes and electrical cables connecting the indoor unit with
the outdoor unit must be fixed to the wall with
suitable ducts.
Must fit tightly against
body without any gap.
Insulation cover pipe
Indoor unit
Be sure to overlap
the insulation
Insulation pipe
All refrigerant connection must be accessible, in order
to permit either unit maintenance or removing it
completely.
5. Select the insulation of the refrigerant pipe.
Insulate the gas side and liquid side pipe referring to the
thickness according to the pipe size.
Indoor temperature of 30°C and humidity of 85% is the stan-
dard condition.
If install in a high humidity condition,use one grade thicker
insulator by referring to the table below.
If installing in an unfavorable conditions,use thicker one.
Insulator’s heat-resistance temperature should be more than
120°C.
Install the insulation not to get wider and use the
adhesives on the connection part of it to prevent
moisture from entering.
Wind the refrigerant pipe with insulation tape
if it is exposed to outside sunlight.
Install the refrigerant pipe respecting that the
insulation does not get thinner on the bent part or
hanger of pipe.
Add the additional insulation if the insulation
plate gets thinner.
Additional insulation
Refrigerant pipe insulation
a×3
a
Hanger
Drain pipe and Drain Hose Installation
AMNLD / AM022/028/036NMD
AMNMD / AMNHD
Pipe Pipe size
Insulation Type(Heating/Cooling)
Remarks
Standard
[30°C
,85%
]
High humidity
[30°C
,over85%
]
EPDM,NBR
Liqued Φ6.35~Φ9.52 9t 9t
Internal temperature
is higher than 120°C
pipe Φ12.7~Φ50.80 13t 13t
Gas
Pipe
Φ6.35 13t 19t
Φ9.52
19t
25t
Φ12.70
Φ15.88
Φ19.05
Φ22.23
Φ25.40
Φ28.58
32t
Φ31.75
Φ38.10
Φ44.45
Φ50.80 25t 38t
1. Install the drain hose as short as possible.
In order to discharge condensation water, the
drain hose should keep tilted.
Fix the drain hose with Cable-Tie, so that it will
not separate from the machine.
The drain pump connection port is used when
using a drain pump.
Note
2. When there is no drain pump, Insulate and fix the drain
hose according to the figure.
Lock steel ring of the drain hose according to the
figure.
Wind and wrap steel ring and drain hose fully
with thermal insulation sponge; fix both ends of
external layer with ribbon for thermal insulation.
Note
A-A’
Large sealing pad
Metal clamp
Drain socket
Drain hose
Cable tie
Drain piping
Indoor
unit
A-A’
Large sealing pad
Metal clamp
Drain socket
Drain hose
Cable tie
Drain piping
Indoor
unit
Tighten the clamp to the maximum.
1Install the drain hose as short as possible.
note In order to discharge condensation water, the
drain hose should keep tilted.
Secure the drain hose with the cable-tie not to be
separated from the unit.
The drain pump connection port is used when using
a drain pump.
2When there is no draining pump, insulate the drain hose
and then fix it as a picture.
note Insert the drain hose to bottom of the outfall of water
basin.
Lock steel ring of the drain hose according to the figure.
Wind and wrap steel ring and drain hose fully with
thermal insulation sponge; fix both ends of external
layer with ribbon for thermal insulation.
After being installed, drain hose must be insulated fully
by heat insulating material.(To be provided at site.)
CAUTION
CAUTION
CAUTION
installing your air conditioner _19
ENGLISH
1. Install horizontal drainpipe with a slope of 1/100 or more and
fix it by hanger space of 1.0~1.5m.
2. Install U-trap at the end of the drainpipe to prevent a nasty
smell to reach the indoor unit.
3. Do not install the drainpipe to upward position.
It may cause water flow back to the unit.
Drainpipe Connection Wiring Work
Silver solder
1. Before wiring work, you must turn off all power source.
2. Indoor unit power should be supplied through the
breaker(ELCB or MCCB+ELB) separated by the outdoor
power.
ELCB: Earth Leakage Circuit Breaker
MCCB:Molded Case Circuit Breaker
ELB:Earth Leakage Breaker
3. The power cable should be used only copper wires.
4. Connect the power cable{1(L), 2(N)} among the units within
maximum length and communication cable(F1, F2) each.
5. Connect F3, F4(for communication) when installing the
wired remote Control.
Power and communication cable connection
Selecting compressed ring terminal
Norminal
dimensions
for cable
(mm
2
)
Norminal
dimensions
for screw
(mm)
B D d1 E F L d2 t
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm) Min. Min. Max.
Standard
dimension
(mm)
Allowance
(mm) Min.
1.5 46.6 ±0.2 3.4 +0.3
-0.2 1.7 ±0.2 4.1 616 4.3 +0.2
00.7
4 8
2.5 46.6 ±0.2 4.2 +0.3
-0.2 2.3 ±0.2 6 6 17.5 4.3 +0.2
00.8
48.5
4 4 9.5 ±0.2 5.6 +0.3
-0.2 3.4 ±0.2 6 5 20 4.3 +0.2
00.9
Specification of electronic wire
Power supply MCCB ELB or ELCB Power
cable
Earth
cable
Communication
cable
Max : 242V
Min : 198V XAXA, 30mmA
0.1 s 2.5mm
2
2.5mm
2
0.75~1.5mm
2
Decide the capacity of ELCB(or MCCB+ELB) by below formula.
Power supply cords of parts of appliances for outdoor use shall not
be lighter than polychloroprene sheathed flexible cord.
(Code designation IEC:60245 IEC 57 / CENELEC: H05RN-F or
IEC:60245 IEC 66 / CENELEC: H07RN-F
)
The capacity of ELCB(or MCCB+ELB) X[A] = 1.25 X 1.1 X ∑Ai
X
: The capacity of ELCB(or MCCB+ELB).
∑
Ai : Sum of Rating currents of each indoor unit.
Refer to each installation manual about the rating current of indoor unit.
Decide the power cable specification and maximum length
within 10% power drop among indoor units.
Coef: 1.55
Lk: Distance among each indoor unit[m],
Ak: Power cable specification[mm
2
], ik: Running current of each unit[A]
∑ ( Coef×35.6×Lk×ik) < 10% of input
voltage[V]
1000×Ak
n
k=1
Without the drain pump
1~1.5m
Horizontal drainpipe
more than 1/100 slope
Ceiling
Hanger
Flexible hose
With the drain pump
1. The drain pipe should be installed within 300mm to 550mm
from the flexible hose and then lift down 20mm or more.
2. Install horizontal drainpipe with a slope of 1/100 or more
and fix it by hanger space of 1.0~1.5m.
3Install the air vent in the horizontal drainpipe to prevent
water flow back to the indoor unit.
You may not need to install it if there were proper
slope in the horizontal drainpipe.
Note
4The flexible hose should not be installed upward position,
it may cause water flow back to the indoor unit.
1~1.5m
20mm
or more
200mm
or more
Hanger
Within
300~550mm
Air vent
300mm or less
Flexible hose
Horizontal drainpipe
more than 1/100 slope
Ceiling
1. Install horizontal drainpipe with a slope of 1/100 or more and
fix it by hanger space of 1.0~1.5m.
2. Install U-trap at the end of the drainpipe to prevent a nasty
smell to reach the indoor unit.
Centralized Drainage
Without the drain pump
100mm or more
Ceiling Horizontal drainpipe
more than 1/100 slope
1. Install main air vent at the front of the farthest indoor unit from
the main drain when installed indoor units are more than 3.
2. You may need to install individual air vent to prevent water
flow back at the top of each indoor unit drainpipe.
With the drain pump
Hanger
Main drainpipe
Individual
air vent
Main air vent
Centralized horizontal drainpipe
(more than 1/100 slope)
550mm
or less
1~1.5m
N L
N L N L N L
ELCB
MCCB+
ELB
V1 V2
Indoor Unit 1
Outdoor
Unit
Wired Remote
Control
220-240V~
h ELCB : Essential Installation
h Ceiling, wall-mounted indoor unit.
Indoor Unit 2 Indoor Unit 3
Indoor Unit 4 Indoor Unit 5 Indoor Unit 6
EEV kit
WARNING
Power off before connecting any wires;
Indoor PBA will be damaged while V1,V2,F3,F4
short each other.
or
20_ installing your air conditioner
Setting an indoor unit address and installation option
Set the indoor unit address and installation option with remote controller option.
Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting
option at the same time. You need to set twice when setting indoor unit address and installation option.
Step 1. Entering mode to set option
1. Remove batteries from the remote controller.
2. Insert batteries and enter the option setting mode while pressing High Temp button and Low Temp button.
3. Check if you have entered the option setting status.
Step 2. The procedure of option setting
After entering the option setting status, select the option as listed below.
The procedure of option setting
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
0XXXXX1XXXXX
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
2XXXXX3XXXXX
On(SEG1~12) O(SEG13~24)
• Option setting is available from SEG1 to SEG 24
• SEG1, SEG7, SEG13, SEG19 are not set as page option.
• Set the SEG2~SEG6, SEG8~SEG12 as ON status and SEG14~18, SEG20~24 as OFF status.
CAUTION
High Temp Button High Fan Button
Mode change
Low Temp Button Low Fan Button
Entering mode for
option setting
Option setting mode
installing your air conditioner _21
ENGLISH
Setting an indoor unit address and installation option
Option setting Status
1. Setting SEG2, SEG3 option
Press Low Fan button(
∨
) to enter SEG2 value.
Press High Fan button(
∧
) to enter SEG3 value.
Each time you press the button,
…
will be selected in rotation.
2. Setting Cool mode
Press Mode button to be changed to Cool mode in the ON status.
3. Setting SEG4, SEG5 option
Press Low Fan button(
∨
) to enter SEG4 value.
Press High Fan button(
∧
) to enter SEG5 value.
Each time you press the button,
…
will be selected in rotation.
4. Setting Dry mode
Press Mode button to be changed to DRY mode in the ON status.
5. Setting SEG6, SEG8 option
Press Low Fan button(
∨
) to enter SEG6 value.
Press High Fan button(
∧
) to enter SEG8 value.
Each time you press the button,
…
will be selected in rotation.
6. Setting Fan mode
Press Mode button to be changed to FAN mode in the ON status.
7. Setting SEG9, SEG10 option
Press Low Fan button(
∨
) to enter SEG9 value.
Press High Fan button(
∧
) to enter SEG10 value.
Each time you press the button,
…
will be selected in rotation.
8. Setting Heat mode
Press Mode button to be changed to HEAT mode in the ON status.
9. Setting SEG11, SEG12 option
Press Low Fan button(
∨
) to enter SEG11 value.
Press High Fan button(
∧
) to enter SEG12 value.
Each time you press the button,
…
will be selected in rotation.
10. Setting Auto mode
Press Mode button to be changed to AUTO mode in the OFF status.
11. Setting SEG14, SEG15 option
Press Low Fan button(
∨
) to enter SEG14 value.
Press High Fan button(
∧
) to enter SEG15 value.
Each time you press the button,
…
will be selected in rotation.
SEG2 SEG3
SEG4
SEG6
SEG9
SEG11
SEG14
SEG5
SEG8
SEG10
SEG12
SEG15
22_ installing your air conditioner
Step 4. Input option
Press operation button with the direction of remote control for set.
For the correct option setting, you must input the option twice.
Step 5. Check operation
1. Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit.
2. Take the batteries out of the remote controller and insert them again and then press the operation button.
Step 3. Check the option you have set
After setting option, press button to check whether the option code you input is correct or not.
Option setting Status
12. Setting Cool mode
Press Mode button to be change to Cool mode in the OFF status.
13. Setting SEG16, SEG17 option
Press Low Fan button(
∨
) to enter SEG16 value.
Press High Fan button(
∧
) to enter SEG17 value.
Each time you press the button,
…
will be selected in rotation.
14. Setting Dry mode
Press Mode button to be change to Dry mode in the OFF status.
15. Setting SEG18, SEG20 option
Press Low Fan button(
∨
) to enter SEG18 value.
Press High Fan button(
∧
) to enter SEG20 value.
Each time you press the button,
…
will be selected in rotation.
16. Setting Fan mode
Press Mode button to be change to Fan mode in the OFF status.
17. Setting SEG21, SEG22 option
Press Low Fan button(
∨
) to enter SEG21 value.
Press High Fan button(
∧
) to enter SEG22 value.
Each time you press the button,
…
will be selected in rotation.
18. Setting Heat mode
Press Mode button to be change to HEAT mode in the OFF status.
19. Setting SEG23, SEG24 mode
Press Low Fan button(
∨
) to enter SEG23 value.
Press High Fan button(
∧
) to enter SEG24 value.
Each time you press the button,
…
will be selected in rotation.
SEG16
SEG18
SEG21
SEG23
SEG17
SEG20
SEG22
SEG24
Setting an indoor unit address and installation option (Cont.)
installing your air conditioner _23
ENGLISH
Setting an indoor unit address and installation option (Cont.)
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional
power supply in the indoor unit.
2. The panel(display) should be connected to an indoor unit to receive option.
3. Before installing the indoor unit, assign an address to the indoor unit according to the air
conditioning system plan.
4. Assign an indoor unit address by wireless remote controller.
- The initial setting status of indoor unit ADDRESS(MAIN/RMC) is “0A0000-100000-200000-300000”.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE Mode Setting Main address 100-digit of indoor
unit address
10-digit of indoor
unit
The unit digit of
an indoor unit
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 A
0No Main
address
0~9 100-digit 0~9 10-digit 0~9 A unit
digit
1
Main
address
setting
mode
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE
__
Setting RMC address
__
Group channel(*16) Group address
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
1
0No RMC
address
RMC1 0~F RMC2 0~F
1
RMC
address
setting
mode
Indoor Unit
1(L) F2
F1
2(N)
Setting an indoor unit address (MAIN/RMC)
Option No. : 0AXXXX-1XXXXX-2XXXXX-3XXXXX
• When “A”~”F” is entered to SEG5~6, the indoor unit MAIN ADDRESS is not changed.
• If you set the SEG 3 as 0, the indoor unit will maintain the previous MAIN ADDRESS even if you
input the option value of SEG5~6.
• If you set the SEG 9 as 0, the indoor unit will maintain previous RMC ADDRESS even if you input
the option value of SEG11~12.
• You cannot set SEG11 and SEG12 as F value at the same time.
CAUTION
24_ installing your air conditioner
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional
power supply in the indoor unit.
2. The panel(display) should be connected to an indoor unit to receive
option.
3. Set the installation option according to the installation condition of an air
conditioner.
- The default setting of an indoor unit installation option is
“020010-100000- 200000-300000”.
- Individual control of a remote controller(SEG20) is the function that controls an
indoor unit individually when there is more than one indoor unit.
4. Set the indoor unit option by wireless remote controller.
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
0 2 --
External room
temperature sensor
/ Minimizing fan
operation when
thermostat is o
Central control FAN RPM
compensation
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1Drain pump Hot water heater -- EEV Step when
heating stops --
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2External control
External control
output / External
heater On or O
signal
S-Plasma ion Buzzer Number of hours
using lter
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3Individual control of
a remote controller
Heating setting
compensation
/ Removing
condensated water in
heating mode
EEV Step of stopped
unit during oil return/
defrost mode
Motion detect
sensor --
1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to ‘USE + 3minute delay’ even if the drain
pump is set to 0.
1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using filter(SEG18) will be set to ‘1000hour’ even
if the SEG18 is set to exept for 2 or 6.
When setting the option other than above SEG values, the option will be set as “0”.
SEG5 central control option is basically set as 1 (Use), so you don’t need to set the central control
option additionally.
However, if the central control is not connected but it doesn’t indicate an error message, you need to
set the central control option as 0 (Disuse) to exclude the indoor unit from the central control.
Indoor Unit
1(L) F2
F1
2(N)
02 series installation option
Setting an indoor unit installation option
(suitable for the condition of each
installation location)
Setting an indoor unit address and installation option (Cont.)
installing your air conditioner _25
ENGLISH
02 series installation option(Detailed)
The external output of SEG15 is generated by MIM-B14 connection. (Refer to the manual of MIM-B14.)
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE Use of robot
cleaning
Use of external room temperature
sensor / Minimizing fan operation when
thermostat is o
Use of central control FAN RPM compensation
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication Details Indication
Details
Indication Details Indication Details
Use of
External
room
temperature
sensor
Minimizing fan
operation when
thermostat is o
0 2
0Disuse
0Disuse Disuse
0Disuse
0Disuse
1Use Disuse 1
RPM
compensation
1Use 2Disuse Use
(
*1
)
1Use 2High ceiling
KIT
3Use Use
(
*1
)
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE Use of drain pump Use of hot water
heater
EEV Step when heating
stops
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
1
0Disuse 0Disuse 0Default
value
1Use 1Use
(
*2
)
1
Noise
decreasing
setting
2
When an indoor
unit stops, drain
pump will operate
for 3min
2--
3Use
(
*2
)
The output of hot water heater in SEG9 is generated from the hot coil part of the terminal board in duct models.
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
* The output of hot coil terminal is AC 220 V / 230 V
(The same as Indoor Unit’s input Power)
F4
F3
F1 F2
V2
V1
1(L) 2(N)
AC
POWER
OUTDOOR
COMMUNICATION
Wire Remote
Controller
DC 12V
COM1 COM2
(+) L N
(-)
Setting an indoor unit address and installation option (Cont.)
26_ installing your air conditioner
Setting an indoor unit address and installation option (Cont.)
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation PAGE Use of external
control
Setting the output of external control
/ External heater On/O signal S-Plasma ion Buzzer control Hours of lter usage
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication
Details
Indication Details Indication Details Indication Details
Setting the
output of
external
control
External
heater On/O
signal
2
0 Disuse 0 Thermo on - 0 Disuse 0 Use buzzer 2 1000 Hour
1ON/OFF
control 1 Operation
on -
1Use
1 Disuse buzzer
6 2000 Hour
2OFF
control 2 - Use
(*3)
3
Window
ON/OFF
control
3 - Use
(*3)
Option SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
Explanation PAGE Individual control of
a remote controller
Heating setting compensation / Removing
condensated water in heating mode
EEV Step of stopped
unit during oil return/
defrost mode
Motion detect sensor -
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication
Details
Indication Details Indication Details
Heating Setting
Compensation
Removing
Condensated
Water in
Heating
Mode
3
0 or 1 channel 1 0 Default
(*4)
Disuse 0Default
value
0 Disuse
1Turn out in 30min.
without motion
2 channel 2 1 2 °C Disuse
1
Oil return
or Noise
decreasing
in defrost
mode
2Turn out in 60min.
without motion
3 channel 3 2 5 °C Disuse 3Turn out in 120min.
without motion
4 channel 4
3 Default
(*4)
Use
(*5)
4Turn out in 180min.
without motion
4 2 °C Use
(*5)
5
Turn out in 30min.
without motion or
*advanced function
55 °C Use
(*5)
6
Turn out in 60min.
without motion or
*advanced function
7
Turn out in 120min.
without motion or
*advanced function
8
Turn out in 180min.
without motion or
*advanced function
installing your air conditioner _27
ENGLISH
Setting an indoor unit address and installation option (Cont.)
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
0 5
Use of Auto Change Over for
HR only in Auto mode
(When setting SEG3)
Standard heating temp.
Oset
(When setting SEG3)
Standard cooling temp.
Oset
(When setting SEG3)
Standard for mode change
Heating → Cooling
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1
(When setting SEG3)
Standard for mode change
Cooling → Heating
(When setting SEG3)
Time required for mode
change
Compensation option for
Long pipe or height
dierence between indoor
units
- -
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2 - - - -
Control variables when using
hot water / external heater
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3 - - - - -
05 series installation option
*
Advanced function: Controlling cooling/heating current or power saving with motion detect.
(*1) Minimizing fan operation when thermostat is o
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
(*2) 1: Fan is turned on continually when the hot water heater is turned on,
3: Fan is turned o when the hot water heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option,install the Mode Select switch(MCM-C200) on the outdoor unit and x it as cool mode.
(*3) When the following 2 or 3 is used as external heater On/O signal, the signal for monitoring external contact control will not be output.
2: Fan is turned on continually when the external heater is turned on,
3: Fan is turned o when the external heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option,install the Mode Select switch(MCM-C200) on the outdoor unit and x it as cool mode.
·
If Fan is set to o for cooling only indoor unit by setting the SEG9=3 or SEG15=3, you need to use an external sensor or wired remote
controller sensor to detect indoor temperature exactly.
(*4) Default setting value
- 4Way Cassette, Mini 4Way Cassette: 5 °C
- Other indoor units: 2 °C
(*5) This function can be applied to 4 Way Cassette and Mini 4 Way Cassette only. If the air conditioner operates the heating mode
immediately after nishing the cooling mode, the condensated water in the drain pan becomes water vapor by the heat of the indoor
unit heat exchanger. Since the water vapor might be condensed on the indoor unit, which may fall into a living space, use this function to
get rid of the water vapor out of the indoor unit by operating the fan (for maximum 20 minutes) even when the indoor unit is turned o
after cooling mode is turned to heating mode .
Air Flow
Suction side Discharge side
Electronic heater should
not be installed.
• Do not install the electronic heater in the ow channel of the indoor unit fan.
Duct Indoor unit
CAUTION
28_ installing your air conditioner
Setting an indoor unit address and installation option (Cont.)
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation
PAGE MODE
Use of Auto Change
Over for HR only in
Auto mode
(When setting SEG3)
Standard heating
temp. Oset
(When setting SEG3)
Standard cooling temp.
Oset
(When setting SEG3)
Standard for mode
change
Heating
→
Cooling
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 5
0
Follow
product
option
00°C 00°C 01°C
1
Use Auto
Change
Over for
HR only
10.5°C 10.5°C 11.5°C
21°C 21°C 22°C
31.5°C 31.5°C 32.5°C
42°C 42°C 43°C
52.5°C 52.5°C 53.5°C
63°C 63°C 64°C
73.5°C 73.5°C 74.5°C
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation
PAGE
(When setting SEG3)
Standard for mode
changing Cooling
→
Heating mode
(When setting SEG3)
Time required for
mode change
Compensation option
for Long pipe or height
diference between
indoor units
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
1
01°C 05 min. 0Use default
value
11.5°C 17 min.
1
1) Height
difference
1)
is more than
30m or
2) Distance
2)
is longer than
110m
22°C 29 min.
32.5°C 311 min.
43°C 413 min.
2
1) Height
difference
1)
is
15~30m or
2) Distance
2)
is
50~110m
53.5°C 515 min.
64°C 620 min.
74.5°C 730 min.
05 series installation option(Detailed)
Option No. : 05XXXX-1XXXXX-2XXXXX-3XXXXX
installing your air conditioner _29
ENGLISH
Setting an indoor unit address and installation option (Cont.)
(*1)
Height dierence : The dierence of the height between the corresponding indoor uint and the indoor unit installed at the lowest place.
For example, When the indoor unit is installed 40m higher than the indoor unit installed at the lowest place, select the
option "1".
(*2)
Distance : The dierence between the pipe length of the indoor unit istalled at farthest place from an outdoor unit and the pipe length of the
corresponding indoor unit from an outdoor unit.
For example, when the farthest pipe length is 100m(328 ft) and the corresponding indoor unit is 40m away from an outdoor unit,
select the option "2".
(100 - 40 = 60m)
(*3) Heater operation when the SEG9 of 02 series installation option is set to using hot water heater or when SEG15 is set to using external heater
e.g. 1) Setting 02 series SEG9 =”1” / Setting 05 series SEG18 = “0”: Hot water heater is turned on at the same time as the heating thermostat is
on, and turned o when the heating thermostat is o.
e.g. 2) Setting 02 series SEG15 =”2” / Setting 05 series SEG18 =”A”:
Room temp. ≤ set temp. + f(heating compensation temp.)
- External heater is turned on when the temperature is maintained as 4.5 °C for 10 minutes.
Room temp. > set temp. + f(heating compensation temp.)
- External heater is turned o when the temperature is maintained as 4.5 °C + 1 °C (1 °C is the Hysteresis for On/O selection.)
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
(*3)
Explanation Control variables when using hot water / external heater
Remote
Controller
Display
Indication
and Details
Indication Details
Set temp. for heater On/O
Delay time for heater On
2
0At the same time as thermo on No delay
1At the same time as thermo on 10 minutes
2At the same time as thermo on 20 minutes
31.5 °C No delay
41.5 °C 10 minutes
51.5 °C 20 minutes
63.0 °C No delay
73.0 °C 10 minutes
83.0 °C 20 minutes
94.5 °C No delay
A4.5 °C 10 minutes
B4.5 °C 20 minutes
C6.0 °C No delay
D6.0 °C 10 minutes
E6.0 °C 20 minutes
30_ installing your air conditioner
Changing a particular option
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE The option mode
you want to change
The tens’ digit of an
option SEG you will
change
The unit digit of an
option SEG you will
change
The changed value
Remote
Controller
Display
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 D Option
mode 1~6 Tens’ digit
of SEG 0~9 Unit digit of
SEG 0~9
The
changed
value
0~F
You can change each digit of set option.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE The option mode
you want to change
The tens’ digit of an
option SEG you will
change
The unit digit of an
option SEG you will
change
The changed value
Indication 0 D 2 1 7 1
• When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’.
• When changing a digit of indoor unit installation option, set the SEG3 as ‘2’.
Ex) When setting the ‘buzzer control’ into disuse status.
Note
SEG 3, 4, 5, 6, 8, 9 additional information
When the SEG 3 is set as "1" and follow Auto Change Over for HR only operation, it will operate as follows.
Cooling/Heating mode can be changed when Thermo O status is maintained during the time with SEG9.
A : Set with SEG4(˚C)
B : Set with SEG5(˚C)
C : Set with SEG6(˚C)
D : Set with SEG8(˚C)
Cooling Thermo O
Heating Thermo O
Cooling Thermo On
Heating Thermo On
B C
D
Ts
A
c
a
Temp.
d
b
Standard temp.
for Heating
Standard temp.
for Cooling
Standard temp. for
Heating
→
Cooling
Standard temp.
for Cooling
→
Heating
Set temp.
for Auto mode
Setting an indoor unit address and installation option (Cont.)
QUESTIONS OR COMMENTS?
Samsung,PO Box 12987, Blackrock, Co. Dublin. Ireland
or Blackbushe Business Park, Yateley, GU46 6GG. UK
COUNTRY CALL
OR VISIT US ONLINE AT
AUSTRIA
0800 72 67 864 (0800-SAMSUNG)
www.samsung.com/at/support
BELGIUM 02-201-24-18
www.samsung.com/be/support
(Dutch)
www.samsung.com/be_fr/support
(French)
BOSNIA 055 233 999
www.samsung.com/ba/support
BULGARIA
*3000 Цена на един градски разговор
0800 111 31 Безплатен за всички
оператори
www.samsung.com/bg/support
CROATIA 072 726 786
www.samsung.com/hr/support
CZECH 800 - SAMSUNG (800-726786)
www.samsung.com/cz/support
DENMARK 707 019 70
www.samsung.com/dk/support
FINLAND 030-6227 515
www.samsung.com//support
FRANCE 01 48 63 00 00
www.samsung.com/fr/support
GERMANY
06196 77 555 77
www.samsung.com/de/support
CYPRUS 8009 4000 only from landline, toll free
www.samsung.com/gr/support
GREECE
80111-SAMSUNG (80111 726 7864) only from
land line
(+30) 210 6897691 from mobile and land line
HUNGARY 0680SAMSUNG (0680-726-7864)
www.samsung.com/hu/support
ITALIA 800-SAMSUNG (800.7267864)
www.samsung.com/it/support
LUXEMBURG
261 03 710
www.samsung.com/be_fr/support
MONTENEGRO
020 405 888
www.samsung.com/support
SLOVENIA
080 697 267 (brezplačna številka)
www.samsung.com/si/support
NETHERLANDS
088 90 90 100
www.samsung.com/nl/support
NORWAY 21629099
www.samsung.com/no/support
POLAND
[IM]
801-172-678* lub +48 22 607-93-33*
Specjalistyczna infolinia do obsługi zapytań
dotyczących telefonów komórkowych:
801-672-678*
* (opłata według taryfy operatora)
[CE]
801-172-678* lub +48 22 607-93-33*
* (opłata według taryfy operatora)
www.samsung.com/pl/support
PORTUGAL 808 207 267
www.samsung.com/pt/support
ROMANIA
*8000 (apel in retea)
08008-726-78-64 (08008-SAMSUNG) Apel
GRATUIT
Atenţie: Dacă efectuaţi apelul din reţeaua
Digi (RCS/RDS), vă rugăm să ne contactaţi
formând numărul Telverde fără ultimele
două cifre, astfel: 0800872678.
www.samsung.com/ro/support
SERBIA 011 321 6899
www.samsung.com/rs/support
SLOVAKIA 0800 - SAMSUNG(0800-726 786)
www.samsung.com/sk/support
SPAIN 91 175 00 15
www.samsung.com/es/support
SWEDEN 0771 726 786
www.samsung.com/se/support
SWITZERLAND
0800 726 786
www.samsung.com/ch/support
(German)
www.samsung.com/ch_fr/support
(French)
UK 0333 000 0333
www.samsung.com/uk/support
IRELAND
(EIRE) 0818 717100
www.samsung.com/ie/support
LITHUANIA 8-800-77777
www.samsung.com/lt/support
LATVIA 8000-7267
www.samsung.com/lv/support
ESTONIA 800-7267
www.samsung.com/ee/support
RUSSIA 8-800-555-55-55
www.samsung.com/ru/support
GEORGIA
0-800-555-555
www.samsung.com/support
ARMENIA
0-800-05-555
www.samsung.com/support
AZERBAIJAN
0-88-555-55-55
www.samsung.com/support
KAZAKHSTAN
8-10-800-500-55-500 (GSM: 7799)
www.samsung.com/kz_ru/support
UZBEKISTAN
00-800-500-55-500 (GSM: 7799)
www.samsung.com/uz_ru/support
KYRGYZSTAN
00-800-500-55-500 (GSM: 9977)
www.samsung.com/support
TAJIKISTAN
8-10-800-500-55-500 (GSM: 8888)
www.samsung.com/support
MONGOLIA
1800-25-55
www.samsung.com/support
BELARUS 810-800-500-55-500
www.samsung.com/support
UKRAINE
0-800-502-000
www.samsung.com/ua/support
COUNTRY CALL
OR VISIT US ONLINE AT
MOLDOVA
+373-22-667-400
www.samsung.com/support
U.A.E
800-SAMSUNG (800 - 726 7864)
www.samsung.com/ae/support (English)
www.samsung.com/ae_ar/support
(Arabic)
OMAN
800-SAM CS (800-72627)
KUWAIT
183-CALL (183-2255)
BAHRAIN
8000-GSAM (8000-4726)
QATAR 800-CALL (800-2255)
EGYPT
08000-7267864
16580
www.samsung.com/eg/support
ALGERIA 3004
www.samsung.com/n_africa/support
PAKISTAN 0800-Samsung (72678)
www.samsung.com/pk/support
TUNISIA 80 1000 12
www.samsung.com/n_africa/support
JORDAN
0800-22273
06 5777444
www.samsung.com/levant/support
IRAN
021-8255 [CE]
021-42132 [HHP]
www.samsung.com/iran/support
MOROCCO
080 100 22 55
www.samsung.com/n_africa/support
SAUDI ARABIA
8002474357 (800 24/7 HELP) From
Inside Saudi Arabia
+966112974690 From outside Saudi
Arabia (May Call Charges will be applied)
www.samsung.com/sa_en/support
(English)
www.samsung.com/sa/support
(Arabic)
TURKEY 444 77 11
www.samsung.com/tr/support
ARGENTINA 0800-555-SAMS(7267)
www.samsung.com/ar
URUGUAY 0800-SAMS(7267)
www.samsung.com/uy
PARAGUAY 0800-11-SAMS(7267)
www.samsung.com/py
BRAZIL
0800 555 0000 (Demais cidades e regiões)
4004-0000 (Capitais e grandes centros)
www.samsung.com/br/support
CHILE 800 726 786
www.samsung.com/cl/support
BOLIVIA 800 107 260
www.samsung.com/cl/support
COLOMBIA
Bogotá en el 600 12 72
Sin costo en todo el pais 01 8000 112 112
Y desde tu celular #726
www.samsung.com/co/support
COSTA RICA 00-800-1-SAMSUNG (726-7864)
www.samsung.com/latin/support
(Spanish)
www.samsung.com/latin_en/
support (English)
DOMINICAN
REPUBLIC 1-800-751-2676
ECUADOR 1-800-SAMSUNG (72-6786)
EL SALVADOR 8000-SAMSUNG (726-7864)
GUATEMALA 1-800-299-0033
HONDURAS 800-2791-9111
JAMAICA 1-800-SAMSUNG (726-7864)
www.samsung.com/latin_en/
support (English)
NICARAGUA 001-800-5077267
www.samsung.com/latin/support
(Spanish)
www.samsung.com/latin_en/
support (English)
PANAMA 800-0101
PUERTO RICO 1-800-682-3180
TRINIDAD
& TOBAGO
1-800-SAMSUNG(726-7864)
PERU
080077708 Desde teléfonos jos, públicos
o celulares www.samsung.com/pe/support
VENEZUELA 0-800-100-5303
www.samsung.com/latin/support
(Spanish)
www.samsung.com/latin_en/
support (English)
AUSTRALIA 1300 362 603 (Other)
1300 425 299 (HHP)
www.samsung.com/au/support
PHILIPPINES
Only for HHP PRODUCT :
#GALAXY (just dial #425-299) [ PLDT / Globe /
Smart / Sun Toll Free ]
02-8-422-2177 [ Standard Landline ]
OTH PRODUCT :
1-800-10-726-7864 [ PLDT Toll Free ]
1-800-8-726-7864 [ Globe Landline and Mobile ]
02-8-422-2111 [ Standard Landline ]
www.samsung.com/ph/support
SINGAPORE
1800 7267864 | 1800-SAMSUNG (Other)
1800 4252997 | 1800-GALAXYS (HHP)
www.samsung.com/sg/support
DB68-03635A-16
Air Conditioner
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
Duct Type Series
Slim duct : AMNLD
AM022/028/036NMD
Ma duct : AMNMD
HSP duct : AMNHD
Home duct : AMMNLD