Samsung AM071JNVDKH User Manual
Displayed below is the user manual for AM071JNVDKH by Samsung which is a product in the Split-System Air Conditioners category. This manual has pages.
Related Manuals
Features of your new air conditioner
Turbo function
You can set the Turbo function to provide fast and powerful cooling (heating).
Easy Filter
There is no grille to remove before separating the lter from the air conditioner! Therefore, lter can
be cleaned easily, more frequently! Frequent lter cleaning will prevent dust from entering into the
product or accumulating on the lter.
Easy Installation
It’s so easy to install! You can easily hang the product on the wall and connect the pipes and wires
by opening the cover on the bottom of the product. Now you won’t have to tilt the product to
connect the pipe and the wires!
function
function will allow you to have deep, good night’s sleep by adjusting the
temperature, fan speed and air ow direction.
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in countries with separate collection systems)
This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be
disposed of with other household waste at the end of their working life. To prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how
they can take these items for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product and its electronic accessories
should not be mixed with other commercial wastes for disposal.
For information on Samsung’s environmental commitments and product specific regulatory obligations e.g. REACH visit: samsung.com/uk/aboutsamsung/
samsungelectronics/corporatecitizenship/data_corner.html
English-2
Contents
Preparation
Safety precautions ..........................................................................................................4
Checking before use ......................................................................................................10
Checking the name of the parts ...........................................................................................11
Using the remote controller ...............................................................................................12
Basic operation
Basic operation ...........................................................................................................15
Timer
Setting the On/O timer ..................................................................................................18
Setting the good'sleep mode..............................................................................................20
Options
Using the Turbo function ..................................................................................................22
Using the Purity function..................................................................................................23
Settings
Selecting an indoor unit...................................................................................................24
Selecting a blade..........................................................................................................24
Others
Cleaning the air conditioner............................................................................................... 25
Maintaining the air conditioner............................................................................................28
Troubleshooting ..........................................................................................................29
Appendix .................................................................................................................31
Installation parts
Installation parts ..........................................................................................................32
English-3
Safety precautions
Before using your new air conditioner, please read this manual thoroughly to ensure
that you know how to safely and eciently operate the extensive features and
functions of your new appliance.
Because the following operating instructions cover various models, the
characteristics of your air conditioner may dier slightly from those described in this
manual. If you have any questions, call your nearest contact center or nd help and
information online at www.samsung.com.
Important safety symbols and precautions:
WARNING
Hazards or unsafe practices that may result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor
personal injury or property damage.
Follow directions. Cut-o the power supply.
Do NOT attempt. Do NOT disassemble.
Make sure the machine is grounded to prevent electric shock.
FOR INSTALLATION
WARNING
Use the power line with the power specications of the product or higher
and use the power line for this appliance only. In addition, do not use an
extension line.
Extending the power line may result in electric shock or fire.
Do not use an electric transformer. It may result in electric shock or fire.
If the voltage/frequency/rated current condition is different, it may cause
fire.
The installation of this appliance must be performed by a qualied
technician or service company.
Failing to do so may result in electric shock, fire, explosion, problems with the
product, or injury and may also void warranty on the installed product.
Install a Isolation Switch next to the Air Conditioner (but not on the panels
of the Air Conditioner)and circuit breaker dedicated to the air conditioner.
Failing to do so may result in electric shock or fire.
Fix the outdoor unit rmly so that the electric part of the outdoor unit is not
exposed.
Failing to do so may result in electric shock, fire, explosion, problems with the
product.
English-4
Do not install this appliance near a heater, inammable material. Do
not install this appliance in a humid, oily or dusty location, in a location
exposed to direct sunlight and water (rain drops). Do not install this
appliance in a location where gas may leak.
This may result in electric shock or fire.
Never install the outdoor unit in a location such as on a high external wall
where it could fall.
If the outdoor unit falls, it may result in injury, death or property damage.
This appliance must be properly grounded. Do not ground the appliance to a
gas pipe, plastic water pipe, or telephone line.
Failure to do so may result in electric shock, fire, and explosion.
Make sure to use a socket-outlet with ground.
FOR INSTALLATION
CAUTION
Install your appliance on a level and hard oor that can support its weight.
Failing to do so may result in abnormal vibrations, noise, or problems with the
product.
Install the draining hose properly so that water is drained correctly.
Failing to do so may result in water overflowing and property damage. Avoid
adding drain to waste pipes as odours may arise in the future.
When installing the outdoor unit, make sure to connect the draining hose
so that draining is performed correctly.
The water generated during the heating operation by the outdoor unit may
overflow and result in property damage.
In particular, in winter, if a block of ice falls, it may result in injury, death or
property damage.
FOR POWER SUPPLY
WARNING
When the circuit breaker is damaged, contact your nearest service center.
Do not pull or excessively bend the power line. Do not twist or tie the
power line. Do not hook the power line over a metal object, place a heavy
object on the power line, insert the power line between objects, or push
the power line into the space behind the appliance.
This may result in electric shock or fire.
English-5
PREPARATION01
Safety precautions
FOR POWER SUPPLY
CAUTION
When not using the air conditioner for a long period of time or during a
thunder/lightning storm, cut the power at the circuit breaker.
Failing to do so may result in electric shock or fire.
FOR USING
WARNING
If the appliance is ooded, please contact your nearest service center.
Failing to do so may result in electric shock or fire.
If the appliance generates a strange noise, a burning smell or smoke, cut-
o the power supply immediately and contact the nearest service center.
Failing to do so may result in electric shock or fire.
In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate
immediately without touching the power line. Do not touch the appliance
or power line.
Do not use a ventilating fan.
A spark may result in an explosion or fire.
To reinstall the air conditioner, please contact your nearest service center.
Failing to do so may result in problems with the product, water leakage,
electric shock, or fire.
A delivery service for the product is not provided. If you reinstall the product in
another location, additional construction expenses and an installation fee will
be charged.
Especially, when you wish to install the product in an unusual location such as
in an industrial area or near the seaside where it is exposed to the salt in the air,
please contact your nearest service center.
Do not touch the circuit breaker with wet hands.
This may result in electric shock.
Do not turn the air conditioner o with the circuit breaker while it is
operating.
Turning the air conditioner off and then on again with the circuit breaker may
cause a spark and result in electric shock or fire.
After unpacking the air conditioner, keep all packaging materials well
out of the reach of children, as packaging materials can be dangerous to
children.
If a child places a bag over its head, it may result in suffocation.
English-6
Do not insert your ngers or foreign substances into the outlet when the air
conditioner is operating.
Take special care that children do not injure themselves by inserting their
fingers into the product.
Do not touch the air ow blade with your hands or ngers during the
heating operation.
This may result in electric shock or burns.
Do not insert your ngers or foreign substances into the air inlet/outlet of
the air conditioner.
Take special care that children do not injure themselves by inserting their
fingers into the product.
Do not strike or pull the air conditioner with excessive force.
This may result in fire, injury, or problems with the product.
FOR USING
WARNING
Do not place an object near the outdoor unit that allows children to climb
onto the machine.
This may result in children seriously injuring themselves.
Do not use this air conditioner for long periods of time in badly ventilated
locations or near inrm people.
Since this may be dangerous due to a lack of oxygen, Open a window at least
once an hour.
If any foreign substance such as water has entered the appliance, cut-o
the power supply and contact the nearest service center.
Failing to do so may result in electric shock or fire.
Do not attempt to repair, disassemble, or modify the appliance yourself.
Do not use any fuse (such as cooper, steel wire, etc.)other than the standard
fuse.
Failing to do so may result in electric shock, fire, problems with the product, or
injury.
English-7
PREPARATION01
Safety precautions
FOR USING
CAUTION
Do not place objects or devices under the indoor unit.
Water dripping from the indoor unit may result in fire or property damage.
(example electrical appliances)
Check that the installation frame of the outdoor unit is not broken at least
once a year.
Failing to do so may result in injury, death or property damage.
Max current is measured according to IEC standard for safety and current is
measured according to ISO standard for energy eciency.
Do not stand on top of the appliance or place objects (such as laundry,
lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.) on
the appliance.
This may result in electric shock, fire, problems with the product, or injury.
Do not operate the appliance with wet hands.
This may result in electric shock.
Do not spray volatile material such as insecticide onto the surface of the
appliance.
As well as being harmful to humans, it may also result in electric shock, fire or
problems with the product.
Do not drink the water from the air conditioner.
The water may be harmful to humans.
Do not apply a strong impact to the remote controller and do not
disassemble the remote controller.
Do not touch the pipes connected with the product.
This may result in burns or injury.
Do not use this air conditioner to preserve precision equipment, food,
animals, plants or cosmetics, or for any other unusual purposes.
This may result in property damage.
Avoid directly exposing humans, animals or plants from the air ow from
the air conditioner for long periods of time.
This may result in harm to humans, animals or plants.
English-8
• Please cover the air conditioner with PE BAG after installation, and remove it when
you start to run air conditioner.
CAUTION
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
For use in Europe : This appliance can be used by children aged from 8
years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children
without supervision.
FOR CLEANING
WARNING
Do not clean the appliance by spraying water directly onto it. Do not use
benzene, thinner or alcohol to clean the appliance.
This may result in discoloration, deformation, damage, electric shock or fire.
Before cleaning or performing maintenance, cut-o the power supply and
wait until the fan stops.
Failing to do so may result in electric shock or fire.
FOR CLEANING
CAUTION
Take care when cleaning the surface of the heat exchanger of the outdoor
unit since it has sharp edges.
This should be done by a qualified technician please contact your installer or
service center.
Do not clean the inside of the air conditioner by yourself.
For cleaning inside the appliance, contact your nearest service center.
When cleaning the internal filter, refer to the descriptions in the ‘Cleaning the
air conditioner’ section.
Failure to do may result in damage, electric shock or fire.
English-9
PREPARATION01
Checking before use
Operation ranges
The table below indicates the temperature and humidity ranges the air
conditioner can be operated within. Refer to the table for ecient use.
Maintaining your air conditioner
The standardized temperature for heating is 7˚C. If the outdoor temperature drops to 0˚C or below, the heating capacity can
be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C(indoor temperature), it does not cool at its full capacity.
Internal protections via the unit control system
This internal protection operates if an internal fault occurs in the air conditioner.
• If the heat pump is operating in Heat mode, defrost cycle is actuated to help remove frost from an outdoor unit that
may have deposited at low temperatures.
The internal fan is switched o automatically and restarted only after the defrost cycle is completed.
Type Description
Against cold air The internal fan will be o to prevent cold air when the heat pump is heating.
Defrost cycle
The internal fan will be o to defrost ice when the heat pump is heating.
Vertical air ow blade will be closed during defrost cycle and it will open again during
heating operation after defrost cycle.
Protect compressor The air conditioner does not start operating immediately to help protect the compressor
of the outdoor unit after it has been started.
MODE OPERATIONAL TEMPERATURE INDOOR HUMIDITY IF OUT OF CONDITIONS
INDOOR OUTDOOR
COOLING 16˚C to 32˚C -5˚C to 48˚ 80% or less
Condensation may occur on the indoor unit
with risk to have either water blow o or drops
on the oor.
HEATING 27˚C or less -20˚C to 24˚C -Internal protection triggers and the air
conditioner will stop.
DRYING 16˚C to 32˚C -5˚C to 48˚C -
Condensation may occur on the indoor unit
with risk to have either water blow o or drops
on the oor.
English-10
Main parts
Checking the name of the parts
Display
Power button/
Remote controller receiver Turbo indicator
Timer/Auto clean indicator
Power indicator
Air lter
Air ow blade
(up and down) Air ow blade
(left and right)
Air intake
Room
temperature
sensor
English-11
PREPARATION01
Using the remote controller
f Point the remote controller towards the remote controller receiver of the indoor unit.
f When you press the button on the remote controller correctly, you will hear beep sound from the indoor unit and a
transmit indicator( ) appears on the remote controller display.
Remote controller buttons
Mode
Selects operation mode.
Air ow direction (Left and right)
Adjusts the air ow direction left and right.
Power
Turns the air conditioner on or o.
Temperature
Adjusts the temperature.
Options
Selects options during operation.
Direction
Moves to select and set an option.
Fan speed
Adjusts the fan speed.
Air ow direction (Up and down)
Adusts the air ow direction up and down
(Not applicable to Duct type models).
SET
Selects or cancels an option.
Settings
Selects settings.
Timer
Sets timer option.
• In case you wish to cancel the options or settings that you have just set, press the Options or Settings button
again, then the most recently selected item will blink and you may simply cancel it by pressing the SET button
while selected item is blinking.
NOTE
English-12
Remote controller display
Operation mode
*Heat mode is applicable to
MR-EH00/MR-EH00U model
only.
Remote controller
transmission
Low battery
Fan speed
Air ow direction
Settings
Set temperature or on/o set
time with the timer function
On/O timer
Options
• For MR-EH00U/MR-EC00U model, the temperature unit will be indicated by "°F" on the display.
• When turning o and turning on the remote controller, the Timer, Options and Settings set before turning o
the remote controller are cancelled. However, the fan direction does not change.
NOTE
Battery changing time
When the battery is exhausted, ( ) will be displayed on the remote controller display. When the icon appears, change the
batteries.
The remote controller requires two 1.5V AAA type batteries.
Storing the remote controller
When you do not use the remote controller for a long time, remove the batteries from the remote controller
and store it in the remote controller holder.
English-13
PREPARATION01
Using the remote controller
Inserting the batteries
1. Open the battery cover of the remote controller.
- Press the ( ) part gently and lift it up in the arrow direction.
2. Insert the batteries.
- Check and match the (+)and (-) signs accordingly.
3. Close the battery cover.
- Match the cover and bottom part of the remote controller and press it until you hear click
sound.
CAUTION
• Make sure that water is not allowed to enter the remote controller.
• There is a possibility that the air conditioner will not operate by remote controller near strong light such as a
uorescent lamp or neon sign. In this case, use the remote controller in front of the remote controller receiver of
the indoor unit.
• If other electrical products are operated by the remote controller, call your nearest service center.
• Filter reset : When the lter reset indicator is turned on the indoor unit display, clean the lter and press the
Settings <, > or Settings (Filter Reset)blinking SET button.
• Beep o : To silence the beep sound, press the Settings <, > or Settings (Beep)blinking SET button. If
you press the Settings <, > or Settings (Beep) blinking SET button again, the beep sound
will ring again.
NOTE
Correct disposal of batteries in this product
(Applicable in countries with separate collection systems)
This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed
of with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb
indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If
batteries are not properly disposed of, these substances can cause harm to human health or the environment.
To protect natural resources and to promote material reuse, please separate batteries from other types of waste and
recycle them through your local, free battery return system.
English-14
Basic operation
Basic operation is an operation mode that can be selected by pressing the Mode button.
Auto
In Auto mode, the air conditioner will automatically adjust the temperature and fan speed to maintain your fresh
environment.
f When the indoor temperature is too high, the powerful cool breeze is generated and when the indoor room becomes
cool enough, the soft breeze is generated.
Cool
Cool mode is frequently used and you can freely control the temperature, fan speed, and air ow direction in Cool mode.
f When you select the Heat mode while the Cool mode is on, the Cool mode is cancelled.
Dry
The air conditioner in Dry mode acts like a dehumidier by removing moisture from the indoor air. The Dry mode will provide
you with fresh air even on a rainy day.
Fan
Fan mode provides you with a breeze just like a fan to make fresh environment for you.
Heat (MR-EH00/MR-EH00U)
In Heat mode, you can warm your room even in the fall and winter.
f The fan may not commence immediately to avoid generating a cold breeze.
f During the Heat mode, defrost operation may be performed to remove the frost formed on the outdoor unit. (When the
frost is removed by the defrost operation in Heat mode, steam is generated from the outdoor unit.)
f If you stop operating the air conditioner after heating operation, the fan will operate for some time to cool the indoor
unit.
f When you select the Cool mode while the Heat mode is on, the Heat mode is cancelled.
• When the outdoor temperature is low and humidity is high during the heat mode, the outdoor unit's heating
capacity may decrease due to the frost formed on the outdoor heat exchanger. The defrost operation removes
the frost formed on the heat exchanger of the outdoor unit for 5 ~ 12 minutes. During the defrost operation, the
indoor unit does not generate breeze in order to prevent cold breeze blowing out.
The interval between the defrost operation can decrease depending on the amount of the frost formed on the
outdoor unit.
The interval between defrost operation can also decrease by humidity level with rain or snow.
NOTE
English-15
BASIC OPERATION02
Basic operation
Turning the air conditioner on
Press the button to operate the air conditioner.
Selecting the operation mode
Press the button to select an operation mode.
Heat mode operates with MR-EH00/MR-EH00U model only.
Adjusting the temperature
Press the button to adjust the temperature.
Auto Temperature can be adjusted by 1°C(1°F) within the range of 18°C(65°F)~30°C(86°F).
Cool Temperature can be adjusted by 1°C(1°F) within the range of 18°C(65°F)~30°C(86°F).
Dry Temperature can be adjusted by 1°C(1°F) within the range of 18°C(65°F)~30°C(86°F).
Fan Temperature cannot be adjusted.
Heat Temperature can be adjusted by 1°C(1°F) within the range of 16°C(61°F) ~30°C(86°F).
Selecting the fan speed
Press the button to adjust the fan speed.
Auto (Auto)
Cool (Auto), (Low), (Med), (High)
Dry (Auto)
Fan (Low), (Med), (High)
Heat (Auto), (Low), (Med), (High)
English-16
Selecting air ow direction
This function allows you to shift the air ow direction up and down or left and right.
Press the or button to move the air ow direction up and down or left and right while
the air conditioner is turned on.
Remote controller display
f When the blade reaches the desired position, press the or button one
more time to set the air ow direction. The up/down and left/right tilting of the
blade will stop.
Duct type model cannot adjust air ow direction up and down.
button not available on RAC.
English-17
BASIC OPERATION02
Setting the On/O timer
You can set the air conditioner to be turned on or o automatically at desired time.
Setting the On timer
When the air conditioner is turned o.
Remote controller display
1. Press the Timer button to select (On).
- (On) indicator will keep blinking and you can set the time.
2. Press the < or > button to set the time.
- You can set the time in half hour unit from 30minutes (0.5 on the display) ~
3hours and hour unit from 3 ~ 24hours.
- Time can be set from minimum 30 minutes to maximum 24hours.
3. Press the SET button to complete the On timer setting.
- (On) indicator and the set time of the timer will be displayed on the remote
controller display.
- On timer setting will be cancelled if you don't press the SET button within
10seconds after setting the time. Therefore, check for the (On) indicator on the
remote controller display.
Cancel f Press the Timer button select (On) press the < or > button
set the timer to press the SET button.
Additional options available in On timer
Select the mode from (Auto) (Cool) (Dry) (Fan) and (Heat).
Heat mode operates with MR-EH00/MR-EH00U model only.
You can adjust the temperature after timer setting is completed.
Temperature adjustment is only available in Auto/Cool/Dry/Heat mode. In Fan mode, temperature cannot be
adjusted.
Heat mode operates with MR-EH00/MR-EH00U model only.
• When On timer setting is completed, the set status will be displayed for 3 seconds, and then only (On) indicator
will remain on the remote controller display thereafter.
NOTE
English-18
Setting the O timer
When the air conditioner is turned on
Remote controller display
1. Press the Timer button to select (O).
- (O) indicator will keep blinking and you can set the time.
2. Press the < or > button to set the time.
- You can set the time in half hour unit from 30minutes (0.5 on the display) ~
3hours and hour unit from 3 ~ 24hours.
- Time can be set from minimum 30 minutes to maximum 24 hours.
3. Press the SET button to complete the O timer setting.
- (O) indicator and the set time of the timer will be displayed on the remote
controller display.
- O timer setting will be cancelled if you don't press the SET button within
10seconds after setting the time. Therefore, check for the (O) indicator on the
remote controller display.
Cancel f Press the Timer button select (O) press the < or > button
set the timer to press the SET button.
• Only the latest setting timer will be applied between the O Timer and
good’ sleep o timer functions.
NOTE
Combining On timer and O timer
When the air conditioner is turned o When the air conditioner is turned on
When set time on On timer is shorter than O timer
e.g. On timer: 3hours, O timer: 5hours
• The air conditioner will be turned on after 3hours from the
moment you have set the timer and the air conditioner will
remain on for 2hours and then be turned o automatically.
When set time on On timer is longer than O timer
e.g. On timer: 3hours, O timer: 1hour
• The air conditioner will be turned o after 1hour from the
moment you have set the timer and will be turned on after
2hours from the moment it was turned o.
• Set time for the On timer and the O timer should be dierent from each other.
• When the On timer or the O timer is set, setting can be cancelled by pressing the Power button.
NOTE
English-19
TIMER03
Setting the good’sleep mode
For a comfortable sleep, the air conditioner will operate in 3 stages in order of ‘Fall asleep Sound sleep Wake up’ stages.
When the air conditioner is operating in Cool mode;
Remote controller display
1. Press the Timer button to select ( ).
- ( ) indicator will keep blinking and you can set the time.
2. Press the < or > button to set the time.
- You can set the time in half hour unit from 30minutes (0.5 on the display) ~
3hours and hour unit from 3 ~ 12hours.
- Time can be set from minimum 30minutes to maximum 12hours.
- Default time setting for the good'sleep mode is 8hours.
3. Press the SET button to complete the good'sleep mode setting.
- ( ) indicator and the set time of the good'sleep mode will be displayed on
the remote controller display.
- good'sleep mode will be cancelled if you don't press the SET button within
10seconds after setting the time. Therefore, check for the ( ) indicator on the
remote controller display.
Cancel f Press the Timer button select ( ) press the < or > button
set the timer to press the SET button.
Additional options available in good'sleep mode
Temperature can be adjusted by 1°C(1°F) within the range of 18°C(65°F)~30°C(86°F).
English-20
Temperature and Fan speed change in good’sleep mode
1. Fall asleep mode : Provides you with comfortable environment for a good sleep by rapid cooling and hypnagogue
expedition breeze.
2. Sound sleep mode : The sound sleep mode adjusts temperature and air ow in waves to maintain healthy skin
temperature while it aids deep sleep. According to the change of good’ sleep operation hours, the sound sleep hour can
be longer or shorter.
3. Wake up from good’sleep mode : Provides you with the air ow that adjusts your body temperature to wake you up in a
fresh status.
• Fan speed and the air ow direction will be adjusted automatically in good'sleep mode.
• Recommended set temperature is between25 °C(77°F) ~ 27°C (81°F) and 26°C(79°F) is the most ideal
temperature.
• If the set temperature is too low, you may feel cold during sleep or catch a cold.
• Optimal operation hour of good'sleep mode is 8 hours. Therefore, if the time is set too short or long, you may not
feel as comfortable as you would expect.
• If the good'sleep mode is set over 5 hours, Wake up stage will begin when 1 hour is remaining in the operation
time and the air conditioner will stop automatically.
• When the On timer and the good'sleep mode are set simultaneously, the air conditioner will only apply the
function that was set later.
• While good'sleep mode is operating, mode can be set additionally by pressing the Options button.
• If you press the Options button and select the Turbo/Quiet function, the good'sleep mode will be cancelled and
the selected mode will begin operation.
• If you press the Mode button, the good'sleep mode will be cancelled and the selected mode will begin
operation.
NOTE
English-21
TIMER03
Using the Turbo function
You can set the Turbo function to provide fast and powerful cooling (heating).
When the air conditioner is operating in Cool or Heat mode;
Remote controller display
1. Press the Options button.
2. Press the <, > or Options button until (Turbo) indicator starts to blink.
3. Press the SET button to set the Turbo function.
- (Turbo) (Turbo) indicator will be displayed on the remote controller display
and Turbo function will operate for 30 minutes.
Cancel f Press the Options button press the <, > or Options button to
make the (Turbo) indicator blink and press the SET button.
• Turbo function is only available in Cool/Heat mode.
Heat mode operates with MR-EH00/MR-EH00U model only.
• If the Turbo function is selected while Quiet function is on, the Quiet
function will be cancelled.
• Air ow direction can be adjusted with every direction.
Duct type model cannot adjust air ow direction up and down.
• Temperature and fan speed cannot be adjusted.
NOTE
English-22
Using the Purity function
Purity function will remove harmful materials in the air to provide you clean and healthy environment.
You can select this function additionally while the air conditioner is in operation.
When the air conditioner is turned on
Remote controller display
1. Press the Options button.
2. Press the <, > or Options button until ( ) indicator starts to blink.
3. Press the SET button to set the Purity function.
- ( ) ( ) indicator will be displayed on the remote controller display and
Ionizer function will begin.
Cancel f Press the Options button press the <, > or Options button to
make the ( ) indicator blink and press the SET button.
• You may select the purity function additionally during Auto/Cool/Dry/
Heat mode and you can adjust the temperature.
Heat mode operates with MR-EH00/MR-EH00U model only.
• If the purity function is selected additionally in fan mode, the temperature
cannot be adjusted.
• When the air conditioner and the purity function are turned on
simultaneously and you press the Power button, both air conditioner and
purity function will stop operation.
• You can still use the purity function when the On timer is set with the air
conditioner is turned o.
• There will not be much dierence on energy consumption and operating
noise when the purity function is selected additionally while the air
conditioner is turned on.
NOTE
When the air conditioner is turned o
Remote controller display
1. Press the Options button.
2. Press the SET button when ( ) indicator blinks to begin purity function.
- ( ) ( ) indicator will be displayed on the remote controller display and
Ionizer function will begin.
Cancel f Press the Options button to make the ( ) indicator blink and press
the SET button.
English-23
OPTIONS04
Selecting an indoor unit
You can select and operate individual indoor units out of 4 indoor units.
When the air conditioner is turned on
Remote controller display
1. Press the Settings button.
2. Press the <, > or Settings button until (Zone) indicator starts to blink.
3. Press the SET button to select the indoor unit you want to operate.
- You can select individual units in order (1~4) or select all indoor units at one time.
Before Selectiing an Indoor unit ,you need setting indoor zone .Reference
installation manual 02 series installation option.
Selecting a blade
You can select and operate individual blades out of 4 blades.
When the air conditioner is turned on
Remote controller display
1. Press the button.
- Blade 1234 will be displayed.
2. Press the Settings button.
3. Press the <, > or Settings button until (Blade) indicator starts to blink.
4. Press the SET button to select the blade you want to operate.
- You can select the individual blades in order (1~4) or select all blades at one time.
button not available on RAC.
• To cancel the selected blade, press the button.
• When selecting the blade individually, button will not work.
NOTE
English-24
Cleaning the air conditioner
Cleaning the indoor unit
Wipe the surface of the unit with a slightly damp micro ber cloth when needed.
• Contact the service center when you clean the indoor unit
heat exchanger because it needs to be disassembled.
• Since the panel of the indoor unit is easily scratched, you
should use a micro ber cloth to clean the panel.
When you use the micro ber cloth, slightly dampen the cloth
and remove any debris on the cloth to avoid scratches.
• Make sure to turn o the power of the indoor unit and cut-o
the power supply before cleaning the air conditioner.
CAUTION
• Do not clean the display using alkaline detergent.
• Do not use sulfuric acid, hydrochloric acid, organic solvents (such as
thinner, kerosene and acetone etc.) to clean the surface of the product
or put any stickers on it.
They may damage the surface of the air conditioner.
CAUTION
English-25
SETTINGS05
Removing the Air lter
There is a hole on the bottom right side of the lter. Put your
nger in that hole to get a grip on the lter and slightly push it up
to release the hooks from the bottom side. Then, pull it down to
remove the lter from the main body.
Cleaning the air lter
Washable foam based air lter captures large particles from the air. The lter is cleaned with a vacuum or by hand washing.
Remove the Air filter from the main body.
Insert the Air filter back in its original position. Dry the Air filter in a ventilated area.
Clean the Air filter with a vacuum cleaner or soft brush.
If dust is too heavy, rinse it with running water.
• Clean the Air lter every 2 weeks. Cleaning term may dier depending on the usage and environmental conditions.
In dusty area, clean it once a week.
• If the Air lter dries in a conned (or humid) area, odors may generate. If it occurs, re-clean and dry it in a
well-ventilated area.
• When the lter clean reminder is on, please press the 2nd F button and then press the Single User button on remote
controller.
Air lter
Cleaning the air conditioner
English-26
Reassembling the Air lter
1. Put the lter on the main body and insert the hooks which are
in the top of the Air lter into the main body.
Air lter
2. There’s one hook in both side of the lter, press the surface of
the Air lter softly and get the hooks into the main body.
3. Press the bottom of the lter lightly to securely x the main
body.
English-27
OTHERS06
Maintaining the air conditioner
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.
1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours
and cut-o the power supply. There may be internal damage if moisture is left
in components.
2. Before using the air conditioner again, dry the inner components of the air
conditioner again by running in Fan mode for 3 to 4 hours. This helps remove
odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type Description Every 2
weeks
Every 3
months
Every 4
months Once a year
Indoor
unit
Clean the air lter (1)
Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the cross fan (2)
Clean the condensate drain pipe (2)
Replace the remote controller batteries (1)
Outdoor
unit
Clean the heat exchanger on the outside of the unit (2)
Clean the heat exchanger on the inside of the unit (2)
Clean the electric components with jets of air (2)
Verify that all the electric components are rmly
tightened (2)
Clean the fan (2)
Verify that all the fan assembly is rmly tightened (2)
Clean the condensate drain pan (2)
: This check mark requires checking the indoor/outdoor unit periodically.
Follow the description to maintain the air conditioner properly.
(1) The described operations should be performed more frequently if
the area of installation is very dusty.
(2) These operations must always be performed by qualied personnel.
For more detailed information, see the installation part in the
manual.
CAUTION
English-28
Troubleshooting
Refer to the following chart if the air conditioner operates abnormally. This may save
time and unnecessary expenses.
PROBLEM SOLUTION
The air conditioner
does not work at all. • Check power status and then operate the air conditioner again.
• Plug in or switch on the circuit breaker and then operate the air
conditioner again.
• Ensure Isolator is switch on.
• Check if you have set the O Timer. Operate the air conditioner
again by pressing the Power button.
The temperature
adjustment is not
working.
• Check if you have selected Fan/Fast mode. In these modes, desired
temperature is set to auto and you cannot adjust the temperature.
Cool/Warm air does
not come out of the
air conditioner.
• Check if the set temperature is higher(during Cool mode)/
lower(during Heat mode) than the current temperature. Press the
Temp + or - button on the remote controller to change the set
temperature.
• Check if the Air lter is blocked by dirt. If there is a lot of dust on
the Air lter, cooling(heating) performance may decrease. Clean
them frequently.
• Check if the outdoor unit is covered or installed near the obstacle.
Take the cover o and take the obstacle away.
• Check if the air conditioner is operating in defrost mode. When the
ice formed in winter or the outdoor temperature is too low, the
air conditioner operates in defrost mode automatically. In defrost
mode, indoor fan stops and warm air does not come out.
• If the doors or windows are open, it may cause bad cooling
(heating) performance.
Close the doors and windows.
• Check if the air conditioner has just been turned on after stopping
cooling or heating operation. In this case, just a fan will run to
protect the outdoor unit compressor.
• Check if the pipe length is too long. When the pipe length exceeds
maximum allowable pipe length, cooling (heating) performance
may decrease.
Air ow adjustment
is not working.
• Check if you have selected mode. In cool mode, you
cannot adjust the air ow direction. (If the mode is
operating in Heat mode, you can adjust the air ow direction.)
English-29
OTHERS06
PROBLEM SOLUTION
Fan speed
adjustment is not
working.
• Check if you have selected Auto/Dry/ mode. In these
mode, fan speed is set to Auto and you cannot adjust the fan
speed.
Remote controller is
not working. • Check if your batteries are depleted.
• Make sure nothing is blocking your remote controller sensor.
• Check that there are strong lighting apparatus near the air
conditioner. Strong light which comes from uorescent bulbs or
neon signs may interrupt the electric waves.
Timer function does
not set. • Check if you press the Set/Cancel button on the remote
controller after you have set the time.
The indicator
is blinking
continuously.
• Press the Power button or disconnect the power plug/switch
o the auxiliary power switch.
If the indicator is still blinking, contact the service center.
Odors permeate in
the room during
operation.
• Check if the appliance is running in a smoky area. Ventilate the
room or operate the air conditioner in Fan mode for 1~2 hours.
(We do not use smelly components in the air conditioner.)
• Check the Drains have been cleared Regular Maintenance.
Error is indicated. • When an indoor unit indicator blinks, contact the nearest service
center. Please ensure the error code is passed onto the service
center when booking the service call.
Noise is generated. • Depending on the status of the air conditioner usage, noise can
be heard when refrigerant ow movement changes. It is normal.
Smoke is generated
from the outdoor
unit.
• If may not be a re but it can be a steam generated by the defrost
operation from outdoor heat exchanger during Heat mode in
winter.
Water is dropping
from the outdoor unit
piping connection.
• Water may be generated because of the temperature dierence.
It is normal.
Troubleshooting
To perform its antimicrobial function this product has been treated with the
biocide substance Silver zinc zeolite.
English-30
Model specication (
Dimension and weight)
Dimension and weight
Type Model Net dimension (WxDxH)
(mm)
Net weight
(kg)
Indoor unit
AM015JNVDKH 750*250*242 8.1
AM022JNVDKH 750*250*242 8.1
AM028JNVDKH 750*250*242 8.2
AM036JNVDKH 826*275*260 9.8
AM045JNVDKH 826*275*260 9.8
AM056JNVDKH 1063*317*294 14.6
AM071JNVDKH 1063*317*294 14.6
AM082JNVDKH 1063*317*294 14.6
AM015JNADKH 750*250*242 7.9
AM022JNADKH 750*250*242 7.9
AM028JNADKH 750*250*242 8.0
AM036JNADKH 826*275*260 9.5
AM045JNADKH 826*275*260 9.5
AM056JNADKH 1063*317*294 14.3
AM071JNADKH 1063*317*294 14.3
AM082JNADKH 1063*317*294 14.3
Appendix
English-31
OTHERS06
Installation parts
English-32
B
A
D
CB
A
D
C
B
A
D
C
Fixing the installation plate
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before xing
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
A
C
B
DD
Direction of pipe
3. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter
of 65mm so that it slants slightly downwards.
• Right (A)
• Left (B)
• Underside_right (C)
• Rear_right or left (D)
Wall
<20mm
Plastic
Anchor
4. Fix the indoor unit.
If you x the indoor unit on a wall
(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.
If you x the indoor unit on a window frame
(1) Determine the positions of the wooden uprights to be attached to the window frame.
(2) Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.
(3) Attach the installation plate to the wooden upright using tapping screws.
If you x the indoor unit on a gypsum board
(1) Use stud nder to nd out locations of the studs.
(2) Fix the plate hanger on two studs.
• If you mount the plate to a concrete wall using plastic anchors, make sure that gaps
between the wall and the plate, created by projected anchor, is less than 20mm.
• Make sure to drill only one hole after choosing the
direction of the pipe.
(Unit : mm)
Model A B C D
015/022/028 36 60 65 36
036/045
36 120 81 36
056/071/082 33 110 110 33
Pipe hole (Ø65 mm) Pipe hole (Ø65 mm)
1. Disassemble the cover panel as described in installation manual.
2. Remove the Hanger plate from the indoor unit.
(1) Unscrew 2 screws that xes the Hanger plate to the indoor unit.
(2) Push the hooks (on the bottom part of the indoor unit) up to release the installation plate from the hooks that holds it.
(3) Pull the installation plate to release it completely from the indoor unit.
Screw
Pipe hole (Ø65 mm)
English-33
INSTALLATION07
Assembling the hanger screw
Use 2 screws to x the indoor unit with hanger plate as shown
in the picture.
Screw
• Search for other spots if there are less than two studs, or the distance between the studs are dierent from the
plate hanger.
• Fix the installation plate without inclining to one side.
• Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not
strong enough to withstand the product weight, the unit could fall and cause injury.
Performing leak test & insulation
Insulation
Pipes
After checking for gas leaks in the system, insulate the pipe, hose and
cables. Then place the indoor unit on the installation plate.
1.
To avoid condensation problems, place heat-resistant polyethylene foam
separately around each refrigerant pipe in the lower part of the indoor unit.
2.
Wrap the refrigerant pipe and the drain hose in the rear of the indoor unit
with the absorbent pad.
Wind the pipe and hose three times to the end of the indoor unit with
the absorbent pad. (20mm interval)
3.
Wind the pipe, assembly cable and drain hose with insulation tape.
4.
Place the bundle (the pipe, assembly cable and drain hose) in the lower
part of the indoor unit carefully so it doesn’t project from the rear of the
indoor unit.
5.
Hook the indoor unit to the installation plate and move the unit to the
right and left until it is securely in place.
6.
Wrap the rest of the pipe with vinyl tape.
7.
Attach the pipe to the wall using clamps (optional).
Installation
plate
Connecting wires
Connecting
pipes
Vinyl tape
Drain hose
LEAK TEST WITH NITROGEN (before opening valves)
In order to detect basic refrigerant leaks, before recreating the vacuum and
recirculating the R410A, it’s responsible of installer to pressurize the whole
system with nitrogen (using a pressure regulator) at a pressure above
4.1MPa (gauge).
LEAK TEST WITH R410A (after opening valves)
Before opening valves, discharge all the nitrogen into the system and
create vacuum. After opening valves check leaks using a leak detector for
refrigerant R410A.
CD
Leak test
• Discharge all the nitrogen to create a vacuum and charge the
system.
Insulation
English-34
Installing and connecting the drain hose of the indoor unit
The drain hose must NOT
slant upwards.
The end of the drain hose
must NOT be placed under
water.
Keep a clearance of at least
5cm between the end of the
drain hose and the ground.
When installing the drain hose for the indoor unit, check if condensation draining is adequate.
When passing the drain hose through the 65 mm hole drilled in the wall, check the followings:
Drain hose installation
1. If necessary, connect the 2 meter extension drain hose to the drain hose.
2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.
3. Fit the drain hose into 1 of 2 drain hose holes, then x the end of the drain hose tightly with a clamp.
4. When extending the Drain Hose, hold the end of Drain Hose and Extended Hose,
rotate and insert the drain hose into Extended hose for 40~45 mm. Make sure the
two hoses are rmly connected, there is no water leakage.
5. Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the
each side of connection by 20 mm .
• If you do not use the other drain hose hole,
block it with a rubber stopper.
Drain hose hole
Wall
Indoor unit
Drain hose
The drain hose must not
be bent.
5cm
less
Do not place the end of the
drain hose in a hollow.
Ditch
After completing the
installation of the drain
hose, pour water into
the drain pan to check
whether the hose is well
drained.
1) Correct connection
Pipe
Drain hose
2) Incorrect connection
Pipe
Drain hose
•
Don’t tie drain hose to the assembly pipe which may lead to water leakage.
English-35
INSTALLATION07
Changing direction of the drain hose
• The hose will be xed permanently into position after nishing the installation and the gas leak test;
refer to page 22 for further details.
• Make sure the installed direction of the drain hose is correct.
Inadequate installation may cause condensate water leakage.
• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the
furniture or oors.
• DO NOT WALL UP THE DRAIN HOSE CONNECTION !
Drain hose connection must be easy accessible and serviceable.
• Make sure the indoor unit is in upright position when you pour water to check for leakage.
Make sure that the water does not overow onto the electrical part.
Change the direction only when it is necessary.
1. Detach the rubber cap with the pliers.
2. Detach the drain hose by pulling it and turning to the left.
3. Insert the drain hose by xing it with the screw into the groove of the drain
hose and the outlet of the drain pan.
4. Attach the rubber cap with a screwdriver by turning it to the right until it
xes to the end of the groove.
5. Check for leakage on both side of the drain outlet.
Drain hose
Screw hole
Screw
Rubber cap
Drain pan outlet
Pour the water in direction of arrow. Direction of the drained water
6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.
7. Pass the drain hose through the hole in the wall. Check if it slants
downwards as seen in the picture.
8. Using natural drainage method, check the drainage is normal.
Shield
Drain hose Extension drain hose
Drain hose Extension
drain hose Drain hose Extension
drain hose
40~45 mm
Foam Insulation
20 mm
or more 20 mm
or more
Vinyl Tape
English-36
Wiring work
N L
N L N L N L
ELCB
MCCB+
ELB
V1 V2
Indoor Unit 1 Indoor Unit 2 Indoor Unit 3
Indoor Unit 4 Indoor Unit 5 Indoor Unit 6
Outdoor Unit
Wired Remote
Control
EEV kit
Ceiling, wall-mounted indoor unit.
220-240V~
or
ELCB : Essential Installation
WARNING :
Power off before connecting any wires;
Indoor PBA will be damaged while V1,V2,F3,F4 short each
other.
Silver solder
Norminal
dimensions
for cable
(mm2)
Norminal
dimensions
for screw
(mm)
B D d1 E F L d2 t
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm)
Standard
dimension
(mm)
Allowance
(mm) Min. Min. Max.
Standard
dimension
(mm)
Allowance
(mm) Min.
1.5 46.6 ±0.2 3.4 +0.3
-0.2 1.7 ±0.2 4.1 616 4.3 +0.2
00.7
4 8
2.5 46.6 ±0.2 4.2 +0.3
-0.2 2.3 ±0.2 6 6 17.5 4.3 +0.2
00.8
48.5
4 4 9.5 ±0.2 5.6 +0.3
-0.2 3.4 ±0.2 6 5 20 4.3 +0.2
00.9
Power and communication cable connection
1.
Before wiring work, you must turn off all power source.
2. Indoor unit power should be supplied through the breaker( ELCB or MCCB+ELB ) separated by the outdoor power.
ELCB : Earth Leakage Circuit Breaker
MCCB : Molded Case Circuit Breaker
ELB : Earth Leakage Breaker
3.
The power cable should be used only copper wires.
4.
Connect the power cable{1(L), 2(N)} among the units within maximum length and communication
cable(F1, F2) each.
5.
Connect F3, F4(for communication) when installing the wired remote control.
Selecting compressed ring terminal
English-37
INSTALLATION07
Power supply MCCB ELB or ELCB Power cable Earth cable Communication cable
Max : 242V
Min : 198V XAXA, 30mmA
0.1 s 2.5mm22.5mm20.75~1.5mm2
Decide the capacity of ELCB(or MCCB+ELB) by below formula.
Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloro-
prene sheathed exible cord.
(Code designation IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC: H07RN-F )
The capacity of ELCB(or MCCB+ELB) X[A] = 1.25 X 1.1 X ∑Ai
X
:
The capacity of ELCB(or MCCB+ELB).
∑
Ai : Sum of Rating currents of each indoor unit.
Refer to each installation manual about the rating current of indoor unit.
Decide the power cable specification and maximum length within 10% power drop among
indoor units.
coef: 1.55
Lk: Distance among each indoor unit[m], Ak: Power cable specification[mm
2
]
ik: Running current of each unit[A]
∑ ( Coef×35.6×Lk×ik) < 10% of input voltage[V]
1000×Ak
n
k=1
Specication of electronic wire
English-38
Set the indoor unit address and installation option with remote controller option.
Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting
option at the same time. You need to set twice when setting indoor unit address and installation option.
Step 1. Entering mode to set option
1. Remove batteries from the remote controller.
2. Insert batteries and enter the option setting mode while pressing High Temp button and Low Temp button.
3.
On
Auto
Check if you have entered the option setting status.
Step 2. The procedure of option setting
After entering the option setting status, select the option as listed below.
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
0 X X X X X 1 X X X X X
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
2 X X X X X 3 X X X X X
On(SEG1~12) O(SEG13~24)
On
Auto Auto
Off
The procedure of option setting
• Option setting is available from SEG1 to SEG 24
• SEG1, SEG7, SEG13, SEG19 are not set as page option.
• Set the SEG2~SEG6, SEG8~SEG12 as ON status and SEG14~18, SEG20~24 as OFF status.
Setting an indoor unit address and installation option
Mode
Selects operation mode.
Air ow direction (Left and right)
Adjusts the air ow direction left and right.
Fan speed
Adjusts the fan speed.
Air ow direction (Up and down)
Adusts the air ow direction up and down
(Not applicable to Duct type models).
SET
Selects or cancels an option.
Settings
Selects settings.
Power
Turns the air conditioner on or o.
Temperature
Adjusts the temperature.
Options
Selects options during operation.
Direction
Moves to select and set an option.
Timer
Sets timer option.
English-39
INSTALLATION07
Option setting Status
1. Setting SEG2, SEG3 option
Press Low Fan button(
∨
) to enter SEG2 value.
Press High Fan button(
∧
) to enter SEG3 value.
Each time you press the button,
…
will be selected in rotation.
On
Auto
On
Auto
2. Setting Cool mode
Press Mode button to be changed to Cool mode in the ON status. On
Cool
3. Setting SEG4, SEG5 option
Press Low Fan button(
∨
) to enter SEG4 value.
Press High Fan button(
∧
) to enter SEG5 value.
Each time you press the button,
…
will be selected in rotation.
On
Cool
Cool
On
4. Setting Dry mode
Press Mode button to be changed to DRY mode in the ON status.
On
Dry
5. Setting SEG6, SEG8 option
Press Low Fan button(
∨
) to enter SEG6 value.
Press High Fan button(
∧
) to enter SEG8 value.
Each time you press the button,
…
will be selected in rotation.
On
Dry
On
Dry
6. Setting Fan mode
Press Mode button to be changed to FAN mode in the ON status.
On
Fan
7. Setting SEG9, SEG10 option
Press Low Fan button(
∨
) to enter SEG9 value.
Press High Fan button(
∧
) to enter SEG10 value.
Each time you press the button,
…
will be selected in rotation.
On
Fan
On
Fan
8. Setting Heat mode
Press Mode button to be changed to HEAT mode in the ON status.
On
Heat
9. Setting SEG11, SEG12 option
Press Low Fan button(
∨
) to enter SEG11 value.
Press High Fan button(
∧
) to enter SEG12 value.
Each time you press the button,
…
will be selected in rotation.
On
Heat
On
Heat
10. Setting Auto mode
Press Mode button to be changed to AUTO mode in the OFF status.
Auto
Off
11. Setting SEG14, SEG15 option
Press Low Fan button(
∨
) to enter SEG14 value.
Press High Fan button(
∧
) to enter SEG15 value.
Each time you press the button,
…
will be selected in rotation.
Auto
Off
Auto
Off
SEG2
SEG4
SEG6
SEG9
SEG11
SEG14
SEG3
SEG5
SEG8
SEG10
SEG12
SEG15
English-40
Option setting Status
12. Setting Cool mode
Press Mode button to be change to Cool mode in the OFF status.
Cool
Off
13. Setting SEG16, SEG17 option
Press Low Fan button(
∨
) to enter SEG16 value.
Press High Fan button(
∧
) to enter SEG17 value.
Each time you press the button,
…
will be selected in rotation.
Cool
Off
Cool
Off
14. Setting Dry mode
Press Mode button to be change to Dry mode in the OFF status. Off
Dry
15. Setting SEG18, SEG20 option
Press Low Fan button(
∨
) to enter SEG18 value.
Press High Fan button(
∧
) to enter SEG20 value.
Each time you press the button,
…
will be selected in rotation.
Off
Dry
Off
Dry
16. Setting Fan mode
Press Mode button to be change to Fan mode in the OFF status.
Off
Fan
17. Setting SEG21, SEG22 option
Press Low Fan button(
∨
) to enter SEG21 value.
Press High Fan button(
∧
) to enter SEG22 value.
Each time you press the button,
…
will be selected in rotation.
Off
Fan
Off
Fan
18. Setting Heat mode
Press Mode button to be change to HEAT mode in the OFF status. Off
Heat
19. Setting SEG23, SEG24 mode
Press Low Fan button(
∨
) to enter SEG23 value.
Press High Fan button(
∧
) to enter SEG24 value.
Each time you press the button,
…
will be selected in rotation.
Off
Heat
Off
Heat
SEG16
SEG18
SEG21
SEG23
SEG17
SEG20
SEG22
SEG24
Step 4. Input option
Press operation button with the direction of remote control for set.
For the correct option setting, you must input the option twice.
Step 5. Check operation
1. Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit.
2. Take the batteries out of the remote controller and insert them again and then press the operation button.
Step 3. Check the option you have set
After setting option, press button to check whether the option code you input is correct or not.
On
Auto
On
Cool
On
Dry
On
Fan
On
Heat
Auto
Off
Cool
Off
Off
Dry
Off
Fan
Off
Heat
Setting an indoor unit address and installation option
English-41
INSTALLATION07
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional
power supply in the indoor unit.
2. The panel(display) should be connected to an indoor unit to receive option.
3. Before installing the indoor unit, assign an address to the indoor unit according to the air
conditioning system plan.
4. Assign an indoor unit address by wireless remote controller.
- The initial setting status of indoor unit ADDRESS(MAIN/RMC) is “0A0000-100000-200000-300000”.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE Mode Setting Main address 100-digit of indoor
unit address
10-digit of indoor
unit
The unit digit of
an indoor unit
Remote
Controller
Display
Auto
On
On
Auto Cool
On
Cool
On On
Dry
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 A
0No Main
address
0~9 100-digit 0~9 10-digit 0~9 A unit
digit
1
Main
address
setting
mode
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE
__
Setting RMC address
__
Group channel(*16) Group address
Remote
Controller
Display
On
Fan
On
Heat
On
Heat
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
1
0No RMC
address
RMC1 0~F RMC2 0~F
1
RMC
address
setting
mode
Indoor Unit
1(L) F2
F1
2(N)
Setting an indoor unit address (MAIN/RMC)
• When “A”~”F” is entered to SEG5~6, the indoor unit MAIN ADDRESS is not changed.
• If you set the SEG 3 as 0, the indoor unit will maintain the previous MAIN ADDRESS even if you
input the option value of SEG5~6.
• If you set the SEG 9 as 0, the indoor unit will maintain previous RMC ADDRESS even if you input
the option value of SEG11~12.
• You cannot set SEG11 and SEG12 as F value at the same time.
Option No. : 0AXXXX-1XXXXX-2XXXXX-3XXXXX
English-42
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional
power supply in the indoor unit.
2. The panel(display) should be connected to an indoor unit to receive
option.
3. Set the installation option according to the installation condition of an air
conditioner.
- The default setting of an indoor unit installation option is
“020010-100000- 200000-300000”.
- Individual control of a remote controller(SEG20) is the function that controls an
indoor unit individually when there is more than one indoor unit.
4. Set the indoor unit option by wireless remote controller.
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
0 2 --
External room
temperature sensor
/ Minimizing fan
operation when
thermostat is o
Central control FAN RPM
compensation
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1Drain pump Hot water heater -- EEV Step when
heating stops --
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2External control
External control
output / External
heater On or O
signal
S-Plasma ion Buzzer Number of hours
using lter
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3Individual control of
a remote controller
Heating setting
compensation
/ Removing
condensated water in
heating mode
EEV Step of stopped
unit during oil return/
defrost mode
Motion detect
sensor --
1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to ‘USE + 3minute delay’ even if the drain
pump is set to 0.
1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using filter(SEG18) will be set to ‘1000hour’ even
if the SEG18 is set to exept for 2 or 6.
When setting the option other than above SEG values, the option will be set as “0”.
SEG5 central control option is basically set as 1 (Use), so you don’t need to set the central control
option additionally.
However, if the central control is not connected but it doesn’t indicate an error message, you need to
set the central control option as 0 (Disuse) to exclude the indoor unit from the central control.
Indoor Unit
1(L) F2
F1
2(N)
02 series installation option
Setting an indoor unit installation option
(suitable for the condition of each installation location)
Setting an indoor unit address and installation option
English-43
INSTALLATION07
02 series installation option(Detailed)
F4
F3
F1 F2
V2
V1
1(L) 2(N)
2
1
HOT
COIL
AC
POWER
OUTDOOR
COMMUNICATION
Wire Remote
Controller
DC 12V
* The output of hot coil terminal is AC 220 V / 230 V
(The same as Indoor Unit’s input Power)
COM1 COM2
(+) L N (-)
The external output of SEG15 is generated by MIM-B14 connection. (Refer to the manual of MIM-B14.)
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE Use of robot
cleaning
Use of external room temperature
sensor / Minimizing fan operation when
thermostat is o
Use of central control FAN RPM compensation
Remote
Controller
Display
Auto
On On
Auto Cool
On
Cool
On
On
Dry
Indication
and Details
Indication Details Indication Details Indication Details Indication
Details
Indication Details Indication Details
Use of
External
room
temperature
sensor
Minimizing fan
operation when
thermostat is o
0 2
0Disuse
0Disuse Disuse
0Disuse
0Disuse
1Use Disuse 1
RPM
compensation
1Use 2Disuse Use
(*1)
1Use 2High ceiling
KIT
3Use Use
(*1)
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE Use of drain pump Use of hot water
heater
EEV Step when heating
stops
Remote
Controller
Display
On
Dry
On
Fan
On
Heat
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
1
0Disuse 0Disuse 0Default
value
1Use 1Use
(*2)
1
Noise
decreasing
setting
2
When an indoor
unit stops, drain
pump will operate
for 3min
2--
3Use
(*2)
The output of hot water heater in SEG9 is generated from the hot coil part of the terminal board in duct models.
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
English-44
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
Explanation PAGE Use of external control Setting the output of external control /
External heater On/O signal S-Plasma ion Buzzer control Hours of lter usage
Remote
Controller
Display
Off
Auto
Off
Auto Cool
Off
Cool
Off
Off
Dry
Indication
and Details
Indication Details Indication Details Indication
Details
Indication Details Indication Details Indication Details
Setting the
output of
external
control
External
heater On/O
signal
2
0Disuse 0 Thermo on - 0 Disuse 0Use buzzer 21000 Hour
1ON/OFF
control 1 Operation
on -
1Use
1Disuse buzzer
62000 Hour
2OFF
control 2 - Use
(*3)
3
Window
ON/OFF
control
3 - Use
(*3)
Option SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
Explanation PAGE Individual control of a
remote controller
Heating setting compensation / Removing
condensated water in heating mode
EEV Step of stopped
unit during oil return/
defrost mode
Motion detect sensor -
Remote
Controller
Display
Off
Dry
Off
Fan
Off
Fan
Off
Heat
Indication
and Details
Indication Details Indication Details Indication
Details
Indication Details Indication Details
Heating Setting
Compensation
Removing
Condensated
Water in
Heating
Mode
3
0 or 1 channel 1 0Default
(*4)
Disuse 0Default
value
0Disuse
1Turn out in 30min.
without motion
2channel 2 12 °C Disuse
1
Oil return
or Noise
decreasing
in defrost
mode
2Turn out in 60min.
without motion
3channel 3 25 °C Disuse 3Turn out in 120min.
without motion
4channel 4
3Default
(*4)
Use
(*5)
4Turn out in 180min.
without motion
42 °C Use
(*5)
5
Turn out in 30min.
without motion or
*advanced function
55 °C Use
(*5)
6
Turn out in 60min.
without motion or
*advanced function
7
Turn out in 120min.
without motion or
*advanced function
8
Turn out in 180min.
without motion or
*advanced function
Setting an indoor unit address and installation option
English-45
INSTALLATION07
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
0 5
Use of Auto Change Over for
HR only in Auto mode
(When setting SEG3)
Standard heating temp.
Oset
(When setting SEG3)
Standard cooling temp.
Oset
(When setting SEG3)
Standard for mode change
Heating → Cooling
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1
(When setting SEG3)
Standard for mode change
Cooling → Heating
(When setting SEG3)
Time required for mode
change
Compensation option for
Long pipe or height
dierence between indoor
units
- -
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2 - - - -
Control variables when using
hot water / external heater
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3 - - - - -
05 series installation option
* Advanced function: Controlling cooling/heating current or power saving with motion detect.
(*1) Minimizing fan operation when thermostat is o
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
(*2) 1: Fan is turned on continually when the hot water heater is turned on,
3: Fan is turned o when the hot water heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option,install the Mode Select switch(MCM-C200) on the outdoor unit and x it as cool mode.
(*3) It isonly for wall-mounted indoor unit with EEV Integrated.
If any design condition meets either of the following below, please set SEG11 to “7”.
a) The total number of wall-mounted indoor units with EEV Integrated in one (modular) system is more than 20.
b) The total number of wall-mounted indoor units with EEV Integrated in one (modular) system is more than“thetotal of one(modular)
system’s capacity(kW) / 2”
(“thetotal of one(modular) system’s capacity(BTU/h) / 6800”).
ex)Outdoor capacity 28kW
→
28 /2 = 14. The total number of wall-mounted indoor units with EEV Integrated in one (modular) system
is more than 14.
Please refer to the EEV step table below for the system (for heating)at stop.
Indication 0 1 2 3 4 5 6 7 8 9 A B
Stopped
Unit's EEV
step
Wall Mounted
With EEV
80 090 100 110 120 130 160 200 250 300 400
Other Indoor Units
except for wall
mounted with EEV
Default 0
No Function
(*4) When the following 2 or 3 is used as external heater On/O signal, the signal for monitoring external contact control will not be output.
2: Fan is turned on continually when the external heater is turned on,
3: Fan is turned o when the external heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option,install the Mode Select switch(MCM-C200) on the outdoor unit and x it as cool mode.
· If Fan is set to o for cooling only indoor unit by setting the SEG9=3 or SEG15=3, you need to use an external sensor or wired remote
controller sensor to detect indoor temperature exactly.
(*5) Default setting value
- 4Way Cassette, Mini 4Way Cassette: 5 °C
- Other indoor units: 2 °C
(*6) This function can be applied to 4 Way Cassette and Mini 4 Way Cassette only. If the air conditioner operates the heating mode immediately
after nishing the cooling mode, the condensated water in the drain pan becomes water vapor by the heat of the indoor unit heat exchanger.
Since the water vapor might be condensed on the indoor unit, which may fall into a living space, use this function to get rid of the water vapor
out of the indoor unit by operating the fan (for maximum 20 minutes) even when the indoor unit is turned o after cooling mode is turned to
heating mode .
English-46
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE
Use of Auto Change
Over for HR only in
Auto mode
(When setting SEG3)
Standard heating
temp. Oset
(When setting SEG3)
Standard cooling temp.
Oset
(When setting SEG3)
Standard for mode
change
Heating
→
Cooling
Remote
Controller
Display
Auto
On On
Auto Cool
On
Cool
On On
Dry
Indication
and Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 5
0
Follow
product
option
00°C 00°C 01°C
1
Use Auto
Change
Over for
HR only
10.5°C 10.5°C 11.5°C
21°C 21°C 22°C
31.5°C 31.5°C 32.5°C
42°C 42°C 43°C
52.5°C 52.5°C 53.5°C
63°C 63°C 64°C
73.5°C 73.5°C 74.5°C
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE
(When setting SEG3)
Standard for mode
changing Cooling
→
Heating mode
(When setting SEG3)
Time required for
mode change
Compensation option
for Long pipe or height
diference between
indoor units
Remote
Controller
Display
On
Dry
On
Fan
On
Fan
Indication
and Details
Indication Details Indication Details Indication Details Indication Details
1
01°C 05 min. 0Use default
value
11.5°C 17 min.
1
1) Height
difference
1)
is more than
30m or
2) Distance
2)
is longer than
110m
22°C 29 min.
32.5°C 311 min.
43°C 413 min.
2
1) Height
difference
1)
is
15~30m or
2) Distance
2)
is
50~110m
53.5°C 515 min.
64°C 620 min.
74.5°C 730 min.
05 series installation option(Detailed)
Option No. : 05XXXX-1XXXXX-2XXXXX-3XXXXX
Setting an indoor unit address and installation option
English-47
INSTALLATION07
(*1) Height dierence : The dierence of the height between the corresponding indoor uint and the indoor unit installed at the lowest place.
For example, When the indoor unit is installed 40m higher than the indoor unit installed at the lowest place, select the
option "1".
(*2) Distance : The dierence between the pipe length of the indoor unit istalled at farthest place from an outdoor unit and the pipe length of the
corresponding indoor unit from an outdoor unit.
For example, when the farthest pipe length is 100m(328 ft) and the corresponding indoor unit is 40m away from an outdoor unit,
select the option "2".
(100 - 40 = 60m)
(*3) Heater operation when the SEG9 of 02 series installation option is set to using hot water heater or when SEG15 is set to using external heater
e.g. 1) Setting 02 series SEG9 =”1” / Setting 05 series SEG18 = “0”: Hot water heater is turned on at the same time as the heating thermostat
is on, and turned o when the heating thermostat is o.
e.g. 2) Setting 02 series SEG15 =”2” / Setting 05 series SEG18 =”A”:
Room temp. ≤ set temp. + f(heating compensation temp.)
- External heater is turned on when the temperature is maintained as 4.5 °C for 10 minutes.
Room temp. > set temp. + f(heating compensation temp.)
- External heater is turned o when the temperature is maintained as 4.5 °C + 1 °C (1 °C is the Hysteresis for On/O selection.)
Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
(*3)
Explanation Control variables when using hot water / external heater
Remote
Controller
Display
Off
Dry
Indication
and Details
Indication Details
Set temp. for heater On/O
Delay time for heater On
2
0At the same time as thermo on No delay
1At the same time as thermo on 10 minutes
2At the same time as thermo on 20 minutes
31.5 °C No delay
41.5 °C 10 minutes
51.5 °C 20 minutes
63.0 °C No delay
73.0 °C 10 minutes
83.0 °C 20 minutes
94.5 °C No delay
A4.5 °C 10 minutes
B4.5 °C 20 minutes
C6.0 °C No delay
D6.0 °C 10 minutes
E6.0 °C 20 minutes
English-48
SEG 3, 4, 5, 6, 8, 9 additional information
When the SEG 3 is set as "1" and follow Auto Change Over for HR only operation, it will operate as follows.
Cooling/Heating mode can be changed when Thermo O status is maintained during the time with SEG9.
A : Set with SEG4
B : Set with SEG5
C : Set with SEG6
D : Set with SEG8
Cooling Thermo O
Heating Thermo O
Cooling Thermo On
Heating Thermo On
B C
D
Ts
A
c
a
Temp.
d
b
Standard temp.
for Heating
Standard temp.
for Cooling
Standard temp. for
Heating
→
Cooling
Standard temp.
for Cooling
→
Heating
Set temp.
for Auto mode
Setting an indoor unit address and installation option
English-49
INSTALLATION07
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE The option mode
you want to change
The tens’ digit of an
option SEG you will
change
The unit digit of an
option SEG you will
change
Changed value
Remote
Controller
Display
On
Auto
On
Auto Cool
On
Cool
On On
Dry
Indication and
Details
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0 D Option
mode 1~6 Tens’ digit
of SEG 0~9 Unit digit
of SEG 0~9
The
changed
value
0~F
You can change each digit of set option.
NOTE
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE The option mode you
want to change
The tens’ digit of an
option SEG you will
change
The unit digit of an
option SEG you will
change
Changed value
Indication 0 D 2 1 7 1
• When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’.
• When changing a digit of indoor unit installation option, set the SEG3 as ‘2’.
Ex) When setting the ‘buzzer control’ into disuse status.
• If you are using heat pump model, mixed operation mode (two or more indoor units operating
in dierent operation mode simultaneously) is not available when the indoor units are
connected to same outdoor unit. If you set the master indoor unit with a remote controller,
outdoor unit will operate in the mode which was set in the master indoor unit.
Changing a particular option
QUESTIONS OR COMMENTS?
SAMSUNG ELECTRONICS CO.,LTD.
No.501 Suhong East Road,Suzhou Industrial Park,Jiangsu Province,P.R.China
SUZHOU SAMSUNG ELECTRONICS CO.,LTD EXPORT
No.218 Jiepu Road,Suzhou Industry Park,Jiangsu Province,P.R.China
Samsung Electronics
Service Department
PO Box 12987, Blackrock, Co. Dublin. Ireland
or
Blackbushe Business Park, Yateley, GU46 6GG. UK
COUNTRY CALL
OR VISIT US ONLINE AT
AUSTRIA 0800 72 67 864 (0800-SAMSUNG)
www.samsung.com/at/support
ALBANIA
045 620 202
www.samsung.com/al/support
BELGIUM 02-201-24-18
www.samsung.com/be/support (Dutch)
www.samsung.com/be_fr/support
(French)
BOSNIA 055 233 999
www.samsung.com/support
BULGARIA *3000 Цена на един градски разговор
0800 111 31 Безплатен за всички оператори
www.samsung.com/bg/support
CROATIA 072 726 786
www.samsung.com/hr/support
CZECH 800 - SAMSUNG (800-726786)
www.samsung.com/cz/support
DENMARK 707 019 70
www.samsung.com/dk/support
FINLAND 030-6227 515
www.samsung.com//support
FRANCE 01 48 63 00 00
www.samsung.com/fr/support
GERMANY 06196 77 555 77
www.samsung.com/de/support
CYPRUS 8009 4000 only from landline, toll free
www.samsung.com/gr/support
GREECE
80111-SAMSUNG (80111 726 7864) only from land line
(+30) 210 6897691 from mobile and land line
HUNGARY 0680SAMSUNG (0680-726-7864)
www.samsung.com/hu/support
ITALIA 800-SAMSUNG (800.7267864)
www.samsung.com/it/support
LUXEMBURG 261 03 710
www.samsung.com/be_fr/support
MONTENEGRO 020 405 888
www.samsung.com/support
SLOVENIA 080 697 267 (brezplačna številka)
www.samsung.com/si/support
NETHERLANDS 088 90 90 100
www.samsung.com/nl/support
NORWAY 21629099
www.samsung.com/no/support
North Macedonia 023 207 777
www.samsung.com/mk/support
POLAND
801-172-678* lub +48 22 607-93-33*
Specjalistyczna infolinia do obsługi zapytań
dotyczących telefonów komórkowych:
801-672-678*
* (opłata według taryfy operatora)
www.samsung.com/pl/support
PORTUGAL 808 20 7267
www.samsung.com/pt/support
ROMANIA
*8000 (apel in retea)
08008-726-78-64 (08008-SAMSUNG) Apel
GRATUIT
Atenţie: Dacă efectuaţi apelul din reţeaua
Digi (RCS/RDS), vă rugăm să ne contactaţi
formând numărul Telverde fără ultimele
două cifre, astfel: 0800872678.
www.samsung.com/ro/support
SERBIA 011 321 6899
www.samsung.com/rs/support
SLOVAKIA 0800 - SAMSUNG(0800-726 786)
www.samsung.com/sk/support
SPAIN 91 175 00 15
www.samsung.com/es/support
SWEDEN 0771 726 786
www.samsung.com/se/support
SWITZERLAND
0800 726 786 (0800-SAMSUNG)
www.samsung.com/ch/support
(German)
www.samsung.com/ch_fr/support
(French)
U.K 0333 000 0333
www.samsung.com/uk/support
IRELAND (EIRE) 0818 717100
www.samsung.com/ie/support
LITHUANIA 8-800-77777
www.samsung.com/lt/support
LATVIA 8000-7267
www.samsung.com/lv/support
ESTONIA 800-7267
www.samsung.com/ee/support
RUSSIA 8-800-555-55-55
www.samsung.com/ru/support
GEORGIA 0-800-555-555
www.samsung.com/support
ARMENIA 0-800-05-555
www.samsung.com/support
AZERBAIJAN 0-88-555-55-55
www.samsung.com/support
KAZAKHSTAN
8-10-800-500-55-500 (GSM: 7799)
www.samsung.com/kz_ru/support
UZBEKISTAN 00-800-500-55-500 (GSM: 7799)
www.samsung.com/support
KYRGYZSTAN 00-800-500-55-500 (GSM: 9977)
www.samsung.com/kz_ru/support
TAJIKISTAN 8-10-800-500-55-500 (GSM: 8888)
www.samsung.com/support
COUNTRY CALL
OR VISIT US ONLINE AT
MONGOLIA 1800-25-55
www.samsung.com/support
BELARUS 810-800-500-55-500
www.samsung.com/support
UKRAINE 0-800-502-000
www.samsung.com/ua/support (Ukrainian)
MOLDOVA +373-22-667-400
www.samsung.com/support
U.A.E 800-SAMSUNG (800 - 726 7864)
www.samsung.com/ae/support (English)
www.samsung.com/ae_ar/support (Arabic)
OMAN 800-SAM CS (800-72627)
KUWAIT 183-CALL (183-2255)
BAHRAIN 8000-GSAM (8000-4726)
QATAR 800-CALL (800-2255)
EGYPT 08000-726786
16580
www.samsung.com/eg/support
ALGERIA 3004
www.samsung.com/n_africa/support
TUNISIA 80 1000 12
MOROCCO 080 100 2255
PAKISTAN 0800-Samsung (72678)
www.samsung.com/pk/support
JORDAN 0800-22273
06 5777444
www.samsung.com/Levant/support
Lebanon 1299
Iraq 80010080
IRAN 021-8255
www.samsung.com/iran/support
SAUDI ARABIA (+966) 8002474357 (800 24/7 HELP)
www.samsung.com/sa_en/support(English)
www.samsung.com/sa/support(Arabic)
TURKEY 444 77 11
www.samsung.com/tr/support
Israel *6963
www.samsung.com/il/support/
ARGENTINA 0800-555-SAMSUNG(7267)
www.samsung.com/ar
URUGUAY 0800-SAMS(7267)
www.samsung.com/uy
PARAGUAY 0800-11-SAMS(7267)
www.samsung.com/py
BRAZIL
0800-124-421 (Demais cidades e regiões)
4004-0000 (Capitais e grandes centros)
www.samsung.com/br/support
CHILE 800-SAMSUNG(726-7864) www.samsung.com/cl/support
BOLIVIA 800-10-7260 www.samsung.com/cl/support
COLOMBIA
Bogotá en el 600 12 72
Sin costo en todo el pais 01 8000 112 112
Y desde tu celular #726
www.samsung.com/co/support
COSTA RICA 00-800-1-SAMSUNG (726-7864)
www.samsung.com/latin/support (Spanish)
www.samsung.com/latin_en/support
(English)
DOMINICAN
REPUBLIC 1-800-751-2676
ECUADOR 1-800-SAMSUN (72-6786)
EL SALVADOR 8000-SAMSUNG (726-7864)
GUATEMALA 1-800-299-0033
HONDURAS 800-2791-9111
JAMAICA 1-800-SAMSUNG (726-7864)
www.samsung.com/latin_en/support
(English)
MEXICO
01-800-SAMSUNG(726-7864)
www.samsung.com/mx/support
NICARAGUA 001-800-5077267
www.samsung.com/latin/support (Spanish)
www.samsung.com/latin_en/support
(English)
PANAMA 800-0101
PUERTO RICO 1-800-682-3180
TRINIDAD &
TOBAGO
1-800-SAMSUNG(726-7864)
VENEZUELA 0-800-100-5303
PERU 080077708 Desde teléfonos jos, públicos
o celulares
www.samsung.com/pe/support
AUSTRALIA 1300 362 603
www.samsung.com/au/support
PHILIPPINES
1-800-10-726-7864 [ PLDT Toll Free ]
1-800-8-726-7864 [ Globe Landline and Mobile ]
02-422-2111 [ Standard Landline ]
www.samsung.com/ph/support
SINGAPORE
1800 7267864 | 1800-SAMSUNG
www.samsung.com/sg/support
AR✴✴FSSSBWK Series
AR✴✴FSSSCUR Series
Air Conditioner
user & installation manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
This manual is made with 100% recycled paper.
AMJNVD Series
AMJNAD Series
Air Conditioner
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.