Sophos AP 100X User Manual
Displayed below is the user manual for AP 100X by Sophos which is a product in the Wireless Access Points category. This manual has pages.
Related Manuals
Operating Instructions
Sophos Access Points
1Wireless Access Points
Operating Instructions
Foreword
We are pleased to welcome you as a new Sophos Access Point customer.
These operating instructions will help you install and configure the access
point and provide technical specifications of all Sophos access point models.
In addition, please also see the following documents that contain useful
information on safety, regulatory compliance, and configuration options:
Ì Sophos Access Points Safety Instructions and Regulatory Information
Ì Sophos UTM Administration Guide: Configuring the
UTM hardware and software appliance
The instructions must be read carefully prior to using the device and should
be kept in a safe place. You may download all user manuals and additional
documentation from the Sophos Knowledgebase at http://www.sophos.com/
en-us/support/knowledgebase.aspx.
Introduction
UTM Wireless Protection simplifies the operation of secure and reliable wireless
networks. It combines affordable and configuration-less access points through
a built-in wireless controller in the in Sophos UTM. The wireless controller itself
centrally manages all wireless access points; all you need to do is plug in the
device anywhere in your network. The access point will find the controller, fetch
its configuration and become operable within seconds. In addition, it easily
provides wireless guest Internet access during the initial setup, unless you
explicitly deny automatic configuration.
Installation
Preliminary steps
Please update your UTM appliance to the latest version available. Note that you
also need a valid UTM Wireless Protection subscription to operate the Sophos
Access Points.
Connect the access point to the internal network
Decide where you would prefer to place the access point, and put the access
point in that location. For mounting instructions, see below. Now connect the
access point to your internal network by plugging in the network cable to the
access point’s RJ45 or LAN (PoE) Ethernet interface, respectively.
2Wireless Access Points
Operating Instructions
Connect the access point to the power supply
The AP 15, AP 15C, AP 55, AP 55C, AP 100, AP 100C, and AP 100X can be
powered directly through the Power-over-Ethernet-injector. Note that it is also
possible to power them by a PoE-compliant switch. For more information on
PoE-injectors, see below.
Connect the AP 15 to the power supply. Please use the power supply from the
scope of supply. Note that the AP 15 can also be operated through a PoE-injector
or PoE-compliant switch.
Start the communication between the access point and the UTM
appliance
When connected to the network, the access point will try to receive an IP address
via DHCP. Therefore, you need either the UTM appliance (with a DHCP server
enabled and listening on the interface the access point is connected to) or any
other DHCP server to provide an IP address for the access point.
After successfully receiving an IP address, the access point will communicate
with the UTM appliance. For this to happen, the UTM appliance needs to be put
in the upstream of the access points, either being the default gateway of the
access points (which was provided by the DHCP service) or on the default route
(most likely your route to the Internet).
Please note that the actual Internet access is not necessary to use UTM Wireless
Protection. While waiting for DHCP and searching for the UTM appliance, the
access point’s power LED will blink slowly.
Enable UTM Wireless Protection on the UTM appliance
In WebAdmin, navigate to the Wireless Protection menu entry. On the Global
Settings tab, click the Enable button. When enabling Wireless Protection for the
first time, the Initial Setup frame will appear. It shows the configuration which will
be created: A separate Wireless “Guest” network using WPA2 personal with DHCP
for wireless clients, which will be allowed to use DNS on the UTM appliance and
the “Web Surfing” service.
The pre-shared key is auto-generated and will only be shown in this section. This
configuration is intended as a template, you can edit the settings at any time
on the Wireless Protection > Wireless Networks tab. You can also skip the initial
setup by ticking the checkbox on the bottom of the section.
3Wireless Access Points
Operating Instructions
Accepting the access point
The UTM appliance will start to communicate with the access point and they
will show up as “Pending” on the Wireless Protection > Access Points tab in
WebAdmin. The ID of the Access Points, shown in square brackets, is also printed
on the bottom of the device. It can be used to distinguish the access point. By
clicking the Accept button, you are given the option to select the channel this
access point will transmit on. When leaving the channel setting on “Auto”, the
access point will use the least used channel.
We also suggest to give the access point a meaningful location (e.g., “Meeting
Room”) as this will ease handling multiple access points. After clicking the Save
button, the access points will reboot. Upon reconnect, the access point will
check if a more recent firmware is available. If so, they will automatically perform
a firmware update. During the firmware update, the access point’s power LED will
blink rapidly.
Important note: Do not unplug the power while the firmware is updating.
Otherwise the access point will be rendered inoperable and must be returned to
the reseller.
The access point will then reboot to complete the firmware update. If no new
firmware is available, the access point is operational and appears as “Active” in
WebAdmin.
Country code selection usage (WLAN devices)
Note: According to FCC regulations, all WLAN devices marketed and sold in
the U.S. must be restricted to U.S. channels only. Therefore, the country code
selection is applicable to non-U.S. models only. So changing the country setting
of any Sophos AP sold in the U.S. will not modify authorized parameters such
as RF channels, which means that the Access Point will always operate in U.S.
authorized channels.
Resetting an access point (models APX320/530/740)
For a normal reboot, press the hardware reset button for 3-5 seconds. Any
configuration will be retained.
For a factory reset, press the hardware resest button for 15-20 seconds. Any
configuration will be removed and the access point needs to be newly registered.
4Wireless Access Points
Operating Instructions
AP 15
Scope of supply
Important note: Sophos AP 15 requires Sophos UTM V 9.207 to be installed.
Mounting instructions
The Sophos AP 15 can be mounted on the wall. Screws are included in delivery.
Controls
LED
Green - blinking slowly AP is booting
Green - blinking rapidly Network connectivity
Orange - blinking slowly No connection to the Sophos UTM
Orange - blinking rapidly Firmware update
Interfaces and buttons
12V DC-IN Power
LAN (PoE) 10/100/1000 Base-TX interface
Technical specifications
Sophos AP 15
Chassis Plastic housing, white
Maximum throughput 300 Mbit/s
LAN interfaces 1 x 10/100/1000 Base-TX
Supported WLAN standards 802.11 b/g/n 2.4 GHz
Antenna 2 x detachable dipole
antenna (2 dBi)
Connector type: RP-SMA
Frequencies / channels ETSI FCC
2.412–2.472 GHz (Channels 1-13) 2.412-2.462 GHz (channels 1-11)
Power supply 12 Vdc / 1 A
Power consumption 2.5 W (max.)
Power-over-Ethernet 802.3af
Dimensions W x H x D 194 x 32 x 115 mm
Weight 260g
Temperature range Operating: 0°C to 45°C Storage: -20°C to 60°C
Humidity (non-condensing) 0% to 90%
Mounting Desktop / wall
Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS)
Number of supported SSIDs 8
Regulatory compliance CE, FCC, IC, CB, cULus, SRRC
Sophos AP 15 Security Notes Power supply 2 Detachable
dipole antenna
2 screws
and dowels
Ethernet
cable
10/100/1000 Base-TX Power
5Wireless Access Points
Operating Instructions
AP 15 Mounting template
Do not shrink to fit when printing
12 cm (4,72 in)
6Wireless Access Points
Operating Instructions
AP 15C
Scope of supply
Important note: Sophos AP 15C requires Sophos UTM V 9.400 to be installed.
Mounting instructions
The Sophos AP 15C can be mounted on the ceiling. Screws are included in
delivery. Use the screws from the scope of supply or screws whose dimensions
correspond with the mounting holes in the bracket.
1. Mount the bracket on the ceiling.
Use the screws and anchors from the scope of supply.
2. Place the access point on the bracket.
Place the housing on the bracket and lock it by turning clockwise until stop.
Controls
LED
Green - blinking slowly AP is booting
Green - blinking rapidly Network connectivity
Orange - blinking slowly No connection to the Sophos UTM
Orange - blinking rapidly Firmware update
Interfaces and buttons
12V DC-IN Power
LAN (PoE) 10/100/1000 Base-TX interface
Security Notes Mounting
bracket
Ethernet
cable
Sophos AP 15C Screws and
T-rail clips
Console Power
10/100/1000 Base-TX
7Wireless Access Points
Operating Instructions
Technical specifications
Sophos AP 15C
Chassis Plastic, white
Physical security Kensington lock
Maximum theoretical
throughput
300 Mbps (5GHz / 802.11an) + 300 Mbps (2.4GHz / 802.11n)
LAN interfaces 1 x 10/100/1000 Base-TX
Supported WLAN standards 802.11a/b/g/n
Antenna 4 x internal antennas
Frequencies / channels ETSI
2.412–2.472 GHz (Channels 1-13) 5.180-5.240GHz
(channels 36-48)
FCC
2.412-2.462GHz (channels 1-11) U-NII-1:
5.180-5.240GHz
(channels 36-48)
U-NII-3:
5.745-5.825GHz
(channels 149-165)
MIC
2.412-2.472GHz (channels 1-13) W52:
5.180-5.240GHz
(channels 36-48)
Power supply 12 Vdc / 1 A
Power consumption 7 W (max.)
Power-over-Ethernet 802.3af
Dimensions W x H x D 176 x 29.86mm
Weight 265g
Temperature range Operating: 0°C to 50°C
Humidity (non-condensing) 0% to 90%
Mounting Ceiling
Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS)
Number of supported SSIDs 8
Regulatory compliance CB, CE, UL, FCC, IC, MIC, VCCI, RCM
8Wireless Access Points
Operating Instructions
AP 55
Scope of supply
Important note: Sophos AP 55 requires Sophos UTM V 9.308 to be installed.
Mounting instructions
The Sophos AP 55 can be mounted on the wall. A mounting kit is included in
delivery.
Controls
LED
Green - blinking slowly AP is booting
Green - blinking rapidly Network connectivity
Orange - blinking slowly No connection to the Sophos UTM
Orange - blinking rapidly Firmware update
Interfaces and buttons
12V DC-IN Power
LAN (PoE) 10/100/1000 Base-TX interface
Console Console access for debugging purposes
USB Currently not used; reserved for future use
Power USB
10/100/1000 Base-TX
Console
Security Notes Ethernet
cable
Sophos AP 55 2 Detachable
dipole antenna
4 screws, dowels
and metal plates
9Wireless Access Points
Operating Instructions
Technical specifications
Sophos AP 55
Chassis Plastic housing, white
Physical security Kensington lock
Maximum theoretical
throughput
867 Mbps (5GHz / 802.11ac) + 300 Mbps (2.4GHz / 802.11n)
LAN interfaces 1 x 10/100/1000 Base-TX
Supported WLAN standards 802.11a/b/g/n/ac
Antenna 2 x detachable dipole
antenna (2 dBi)
Connector type: RP-SMA
Frequencies / channels ETSI
2.412–2.472 GHz (Channels 1-13) RLAN sub-band 1:
5.180-5.320GHz
(channels 36-64)
RLAN sub-band 2:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
FCC
5.180-5.240GHz
(channels 36-48)
U-NII-1:
5.180-5.240GHz
(channels 36-48)
U-NII-2:
5.260-5.320GHz
(channels 52-64)
U-NII-2e:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
U-NII-3:
5.745-5.825GHz
(channels 149-165)
Power supply 12 Vdc / 4 A
Power consumption 17 W (max.)
Power-over-Ethernet 802.3at
Dimensions W x H x D 183 x 36 x 183 mm
Weight 500g
Temperature range Operating: 0°C to 50°C
Humidity (non-condensing) 0% to 90%
Mounting Desktop / wall
Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS)
Number of supported SSIDs 8 per radio (16 in total)
Regulatory compliance CE, FCC, IC, CB, cULus, MIC, VCCI
10Wireless Access Points
Operating Instructions
AP 55C
Scope of supply
Important note: Sophos AP 55C requires Sophos UTM V 9.308 to be installed.
Mounting instructions
The Sophos AP 55C can be mounted on the ceiling. Screws are included in
delivery. Use the screws from the scope of supply or screws whose dimensions
correspond with the mounting holes in the bracket.
1. Mount the bracket on the ceiling.
Use the screws and anchors from the scope of supply.
2. Place the access point on the bracket.
Place the housing on the bracket and lock it by turning clockwise until stop.
Controls
LED
Green - blinking slowly AP is booting
Green - blinking rapidly Network connectivity
Orange - blinking slowly No connection to the Sophos UTM
Orange - blinking rapidly Firmware update
Interfaces and buttons
12V DC-IN Power
LAN (PoE) 10/100/1000 Base-TX interface
Security Notes Mounting
bracket
Ethernet
cable
Sophos AP 55C Screws and
T-rail clips
Power
10/100/1000 Base-TX
11Wireless Access Points
Operating Instructions
Technical specifications
Sophos AP 55C
Chassis Top enclosure: plastic, white; bottom enclosure: metal, white
Physical security Kensington lock
Maximum theoretical
throughput
867 Mbps (5GHz / 802.11ac) + 300 Mbps (2.4GHz / 802.11n)
LAN interfaces 1 x 10/100/1000 Base-TX
Supported WLAN standards 802.11a/b/g/n/ac
Antenna 4 x internal antennas
Frequencies / channels ETSI
2.412–2.472 GHz (Channels 1-13) RLAN sub-band 1:
5.180-5.320GHz
(channels 36-64)
RLAN sub-band 2:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
FCC
2.412-2.462GHz (channels 1-11) U-NII-1:
5.180-5.240GHz
(channels 36-48)
U-NII-2:
5.260-5.320GHz
(channels 52-64)
U-NII-2e:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
U-NII-3:
5.745-5.825GHz
(channels 149-165)
Power supply 12 Vdc / 1.5 A
Power consumption 20 W (max.)
Power-over-Ethernet 802.3at
Dimensions W x H x D 200 x 37mm
Weight 630g
Temperature range Operating: 0°C to 50°C
Humidity (non-condensing) 0% to 90%
Mounting Ceiling
Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS)
Number of supported SSIDs 8 per radio (16 in total)
Regulatory compliance CE, FCC, IC, CB, cULus, SRRC, NCC, BSMI
12Wireless Access Points
Operating Instructions
AP 100
Scope of supply
Important note: Sophos AP 55 requires Sophos UTM V 9.308 to be installed.
Mounting instructions
The Sophos AP 55 can be mounted on the wall. A mounting kit is included in
delivery.
Controls
LED
Green - blinking slowly AP is booting
Green - blinking rapidly Network connectivity
Orange - blinking slowly No connection to the Sophos UTM
Orange - blinking rapidly Firmware update
Interfaces and buttons
12V DC-IN Power
LAN (PoE) 10/100/1000 Base-TX interface
Console Console access for debugging purposes
USB Currently not used; reserved for future use
Power USB
10/100/1000 Base-TX
Console
Security Notes Ethernet
cable
4 screws, dowels
and metal plates
Sophos AP 100 3 Detachable
dipole antenna
13Wireless Access Points
Operating Instructions
Technical specifications
Sophos AP 100
Chassis Plastic housing, white
Physical security Kensington lock
Maximum theoretical
throughput
1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n)
LAN interfaces 1 x 10/100/1000 Base-TX
Supported WLAN standards 802.11a/b/g/n/ac
Antenna 3 x detachable dipole
antenna (2 dBi)
Connector type: RP-SMA
Frequencies / channels ETSI
2.412–2.472 GHz (Channels 1-13) RLAN sub-band 1:
5.180-5.320GHz
(channels 36-64)
RLAN sub-band 2:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
FCC
2.412-2.462GHz (channels 1-11) U-NII-1:
5.180-5.240GHz
(channels 36-48)
U-NII-2:
5.260-5.320GHz
(channels 52-64)
U-NII-2e:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
U-NII-3:
5.745-5.825GHz
(channels 149-165)
Power supply 12 Vdc / 4 A
Power consumption 17 W (max.)
Power-over-Ethernet 802.3at
Dimensions W x H x D 183 x 36 x 183 mm
Weight 505g
Temperature range Operating: 0°C to 50°C
Humidity (non-condensing) 0% to 90%
Mounting Desktop / wall
Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS)
Number of supported SSIDs 8 per radio (16 in total)
Regulatory compliance CE, FCC, IC, CB, cULus
14Wireless Access Points
Operating Instructions
AP 100C
Scope of supply
Important note: Sophos AP 100C requires Sophos UTM V 9.308 to be installed.
Mounting instructions
The Sophos AP 100C can be mounted on the ceiling. Screws are included in
delivery. Use the screws from the scope of supply or screws whose dimensions
correspond with the mounting holes in the bracket.
1. Mount the bracket on the ceiling.
Use the screws and anchors from the scope of supply.
2. Place the access point on the bracket.
Place the housing on the bracket and lock it by turning clockwise until stop.
Controls
LED
Green - blinking slowly AP is booting
Green - blinking rapidly Network connectivity
Orange - blinking slowly No connection to the Sophos UTM
Orange - blinking rapidly Firmware update
Interfaces and buttons
12V DC-IN Power
LAN (PoE) 10/100/1000 Base-TX interface
Security Notes Mounting
bracket
Ethernet
cable
Sophos AP 100C Screws and
T-rail clips
Power
10/100/1000 Base-TX
15Wireless Access Points
Operating Instructions
Technical specifications
Sophos AP 100C
Chassis Top enclosure: plastic, white; bottom enclosure: metal, white
Physical security Kensington lock
Maximum theoretical
throughput
1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n)
LAN interfaces 1 x 10/100/1000 Base-TX
Supported WLAN standards 802.11a/b/g/n/ac
Antenna 6 x internal antennas
Frequencies / channels ETSI
2.412–2.472 GHz (Channels 1-13) RLAN sub-band 1
5.180-5.320GHz
(channels 36-64)
RLAN sub-band 2:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
FCC
2.412-2.462GHz (channels 1-11) U-NII-1:
5.180-5.240GHz
(channels 36-48)
U-NII-2:
5.260-5.320GHz
(channels 52-64)
U-NII-2e:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
U-NII-3:
5.745-5.825GHz
(channels 149-165)
Power supply 12 Vdc / 1.5 A
Power consumption 20 W (max.)
Power-over-Ethernet 802.3at
Dimensions W x H x D 200 x 37mm
Weight 630g
Temperature range Operating: 0°C to 50°C
Humidity (non-condensing) 0% to 90%
Mounting Ceiling
Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS)
Number of supported SSIDs 8 per radio (16 in total)
Regulatory compliance CE, FCC, IC, CB, cULus, NCC, BSMI
16Wireless Access Points
Operating Instructions
AP 100X
Scope of supply
Important note: Sophos AP 100X requires Sophos UTM V 9.308 to be installed.
Mounting instructions
The Sophos AP 100X can be mounted on a pole. A mounting kit is included in
delivery.
Warning: The equipment has a separate protective earthing terminal on the
chassis that must be permanently connected to earth ground to adequately
ground the chassis and protect the operator from electrical hazards.
Caution: Before equipment installation begins, ensure that a service personnel
has attached an appropriate grounding lug to the grounding cable that you supply.
Power installation must be performed with qualified electrician and followed with
National Electrical Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I, CSA
C22.1.
To connect earth ground to Unit:
1. Connect one end of the grounding cable to a proper earth ground.
2. Place the grounding lug attached to the grounding
cable over the protective earthing terminal.
3. Secure the grounding lug to the protective earthing
terminal with the washers and screws.
4. Dress the grounding cable and ensure that it does not
touch or block access to other components.
Warning: At first before powered on, connect the frame of the unit to earth. For
earthing wire, green-and-yellow insulation is required and the cross-sectional
area of the conductor must be more than 0.75mm2 or 18 AWG.
Connect a ground cable from the outdoor unit to an
appropriate grounding point.
10/100/1000 Base-TX
Security Notes Ethernet
cable
Sophos AP 100X 6 Detachable
dipole antenna
1 wall mount plate Grounding wire
4 wood screws
and wood/gyprock
plug, 4 M6 screws
and washers
1 M25
cable gland
2 metal straps
17Wireless Access Points
Operating Instructions
Controls
LED
Power (Green) - continuously on Power on
WLAN (Green) - blinking rapidly WLAN activity
WLAN (Green) - blinking regularly Firmware update
LAN (Green) - blinking rapidly Network connectivity
Interfaces and buttons
LAN (PoE) 10/100/1000 Base-TX interface
Reset Currently not supported
Technical specifications
Sophos AP 100X
Chassis Metal housing, white
IP Code 67
Maximum throughput 1.3 Gbps (5GHz / 802.11ac) + 450 Mbps (2.4GHz / 802.11n)
Number of radios 2
MIMO capabilities 3x3:3
LAN interfaces 1 x 10/100/1000 Base-TX
Antenna 6 x external dipole antenna Connector type: N-Type
Antenna gain 4 dBi @ 2.4GHz, 6 dBi @5GHz
Supported WLAN standards 802.11a/b/g/n/ac
Frequencies / channels ETSI
2.412-2.472GHz (channels 1-13) RLAN sub-band 2:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
FCC
2.412-2.462GHz (channels 1-11) U-NII-2:
5.260-5.320GHz
(channels 52-64)
U-NII-2e:
5.500-5.580GHz
(channels 100-116)
5.660-5.700GHz
(channels 132-140)
U-NII-3:
5.745-5.825GHz
(channels 149-165)
Power supply PoE only
Power consumption 17 W (max.)
Power-over-Ethernet 802.3at
Dimensions W x H x D 255 x 225 x 90 mm
Weight 2.5kg
Temperature range Operation: -20°C to 60°C Storage: -30°C to 60°C
Humidity (non-condensing) Operation: 0% to 90% Storage: 0% to 95%
Mounting Wall / Pole
Supported security standards WPA/WPA2, WEP, 802.1X (RADIUS)
Multiple SSIDs 8 per radio, 16 in total
Regulatory compliance CE, FCC, IC, CB, cULus
18Wireless Access Points
Operating Instructions
Power-over-Ethernet injector
Separate accessory to be used for the following Sophos Access
Points: AP 15C, AP 55, AP 55C, AP 100, AP 100C and AP 100X
The PoE injector converts alternating current (AC) to direct current (DC), which is
then provided over the Ethernet cable to power the Sophos Access Points.
Installation
Warning: Do not use crossover cable between the PoE injector’s output port and
the access point.
Before placing the PoE injector, please pay attention to the following safety
instructions:
Ì Do not cover the PoE injector or block the airflow to the PoE
with any foreign objects. Keep the PoE away from excessive
heat and humidity and free from vibration and dust.
Ì Ensure that the cable length from Ethernet network source to
the access point does not exceed 100 m (330 ft). The PoE is not
a repeater and does not amplify the Ethernet data signal.
To install the PoE injector, proceed as follows:
1. Connect an Ethernet cable to the Data & Power Out interface.
2. Connect the other end of this Ethernet cable to the
Ethernet interface of the access point.
3. Connect an Ethernet cable to the Data In interface.
4. Connect the other end of this Ethernet cable to your network switch.
5. Connect the AC power cord from the scope of supply to the PoE injector.
6. Connect the AC power cable to an AC outlet
(100-240 VAC).
Controls
LED display
Off Power off
Yellow continuously Power on
Green continuously A remote terminal is connected
Green blinking Overload state or short-circuit
Interfaces
Input (Data In) 1 x 10/100/1000 Base-TX
Output (Data & Power Out) 1 x 10/100/1000 Base TX, plus 55 VDC
Data &
Power
Out
LED
Data In
Power
19Wireless Access Points
Operating Instructions
Technical specifications
Power-over-Ethernet injector
Chassis Plastic housing
Input power AC Input Voltage: 100 to 240 VAC
AC Input Current: 0.8A @ 100-240 VAC
AC Frequency: 50 to 60 Hz
Power-over-Ethernet
output (max.)
Output power voltage: 55 VDC
Output power: 30 W
Supported PoE standard 802.3at compliant
Weight 200g
Dimensions W x H x D 1 x 10/100/1000 Base TX, plus 55 VDC
Mounting Desktop / wall
Temperature range Operation: 0°C to 40°C Storage: -20°C to 70°C
Humidity (non-condensing) 10% to 90%
Regulatory compliance CE, FCC, VCCI, UL, GS, RoHS, WEEE
Operating Instructions
United Kingdom and Worldwide Sales
Tel: +44 (0)8447 671131
Email: sales@sophos.com
North American Sales
Toll Free: 1-866-866-2802
Email: nasales@sophos.com
Australia and New Zealand Sales
Tel: +61 2 9409 9100
Email: sales@sophos.com.au
Asia Sales
Tel: +65 62244168
Email: salesasia@sophos.com
© Copyright 2017-18. Sophos Ltd. All rights reserved.
Registered in England and Wales No. 2096520, The Pentagon, Abingdon Science Park, Abingdon, OX14 3YP, UK
Sophos is the registered trademark of Sophos Ltd. All other product and company names mentioned are
trademarks or registered trademarks of their respective owners.
18-06-21 OINA (3035-DD)