Remove the SFPInstall the SFP
TL-SM311 Series Mini GBIC Module
©2017 TP-Link 7106507673 REV3.0.1
For more information, please visit our website:
http://www.tp-link.com
1. Wear an ESD-preventive wrist or ankle strap to prevent ESD damage to
the transceiver.
2. Insert the SFP into the SFP slot and rmly press it into place.
3. Remove the protective dust plug from the SFP.
4. Plug a ber-optic cable into the SFP. Note that the SFP works without
any additional conguration.
1. Wear an ESD-preventive wrist or ankle strap to prevent ESD damage
to the transceiver.
2. Disconnect the network ber-optic cable from the SFP.
4. Reinstall the protective dust plug in the SFP’s optical bores and place it
on antistatic mat or a static shielding bag.
3. Pull the safety latch downwards to release the SFP, and then pull it out
from the slot.
Installation Guide
TL-SM311LS/TL-SM311LM
Note:
1. Do not touch the output pins on the transceiver with your hand.
2. Always keep the protective dust plug on the SFP’s optical bores until you are ready to make a connection.
Caution:
DO NOT point or stare directly into the beam or into the optical port of the transceiver when it is operating, as this can injure your eyesight.
Only use the same transceiver model between switches for fast and reliable connectivity.
Connection
Port Type
Fiber Type
Data Rate
Wave Length 1310nm
IEEE 802.3z, CSMA/CD, TCP/IP
Single-mode Fiber Multi-mode Fiber
9/125 um Single-mode 50/125 um or 62.5/125
um Multi-mode
10km 550m
1.25Gbps
LC
3.3V
FCC, CE
850nm
Standards and Protocols
Operation Temperature 0˚C to 70˚C (32˚F to 158˚F)
Storage Temperature -40˚C to 80˚C (-40˚F to 176˚F)
Storage Humidity 5% to 90% RH, Non-condensing
Operation Humidity
Cable
10% to 90% RH, Non-condensing
Normal TL-SM311LMTL-SM311LS
General Specications Environmental and Physical Specications
Max. Cable Length
Power Support
Safety & Emission
TP-Link Compatible Products
Note:
The SFP modules may be incompatible with other vendors’ devices. We
recommend that you use only TP-Link SFP modules on your TP-Link devices.
Specications
Switch Switch
TL-SM311-LS
Fiber
TL-SM311-LS
TP-Link Switches with gigabit SFP Slots
MC220L
For technical support and other information, please visit
http://www.tp-link.com/support, or simply scan the QR code.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired
operation.
Any changes or modications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC STATEMENT
This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may
be required to take adequate measures.
CE Mark Warning
Industry Canada Statement
CAN ICES-3 (B)/NMB-3(B)
EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant
provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC and 2011/65/EU.
The original EU declaration of conformity may be found at http://www.tp-link.com/en/ce
Safety Information
•Keep the device away from water, re, humidity or hot environments.
•Do not attempt to disassemble, repair, or modify the device.
• Do not use damaged charger or USB cable to charge the device.
•Do not use any other chargers than those recommended.
•Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.
BSMI Notice
安全諮詢及注意事項
請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。
清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。
注意防潮,請勿將水或其他液體潑灑到本產品上。
插槽與開口供通風使用,以確保本產品的操作可靠並防止過熱,請勿堵塞或覆蓋開口。
請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不可放在密閉位置中。
請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。
限用物質含有情況標示聲明書
產品元件名稱
PCB
外殼
產品元件名稱
PCB
外殼
限用物質及其化學符號
備考: "○"系指該項限用物質之百分比含量未超出百分比含量基準值。
鉛
Pb
○
○
鎘
Cd
○
○
汞
Hg
○
○
六價鉻
CrVI
○
○
多溴聯苯
PBB
○
○
多
溴二苯醚
PBDE
○
○
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам нормативних
документів та вимогам, що передбачені чинними законодавчими актами України.