Vertiv Liebert APM User Manual
Displayed below is the user manual for Liebert APM by Vertiv which is a product in the Uninterruptible Power Supplies (UPSs) category. This manual has pages.
Related Manuals
Liebert® APM from 30 - 150 kW
The Compact Row-Based UPS With FlexPower TechnologyTM
AC Power for
Business-Critical Continuity™
2
Regardless of your size,
you can’t afford for your
critical business systems
to go down and you can’t
waste time recovering your
IT infrastructure after a
disruption.
Leave that to us, the experts
in business-critical continuity:
from grid to chip, from the
biggest to the smallest
data centers, we are ready
to serve your needs with the
solutions we have developed.
More standardization,
so you don’t need further
budget allocations to install it.
More simplication so you
don’t need to be a specialist
to get the best for your
business.
More support, so while you
are enjoying doing business,
we are protecting you.
Emerson Network Power, a division of Emerson, is a global company that combines technology
with design to supply innovative solutions for the benet of its customers.
Emerson Network Power is the leader in the “business-critical continuity” eld, thanks to the
company’s products and services.
Emerson Network Power’s broad technology base and global expertise support a full spectrum of
enterprise-wide solutions for today’s vital business needs.
3
4
Features and Performances
• Industry’s highest double
conversion efciency - up to
96%
• Flat efciency curve
• Highest power density in the
market
• Rack architecture
• Modular and scalable
• Hot- swappable power
modules
• Independent module control
system
• Unitary output power factor
and symmetrical power
factor diagram
• Integrated parallel and load
bus synchronization
• 4.5 kW battery charger per
power module
• Integrated autonomy for
ratings up to 90 kW
The Liebert® APM is a compact,
row-based, transformer-free
UPS designed to operate with a
maximum energy efciency of
up to 96% for the protection of
medium sized business-critical
applications.
Its modular rack conguration
houses both power and battery
modules inside the same UPS
cabinet, allowing for scalability
while delivering the ideal balance
of high availability, reliability and
efciency without increasing the
system footprint.
The in-built scalability of the
Liebert® APM also allows for
fast, simple increases in system
capacity through featured
FlexPower technology™. Each
30 kW power module combines
scalable power with independent
DSP control to auto-regulate
operation, thus enhancing overall
availability.
The Liebert® APM is able to reach a
total of 150 kW of active power in
a single unit and up to a maximum
of 600 kW in a complete parallel
conguration. At the same time
it delivers an excellent integrated
autonomy of up to 30 minutes
for a 30 kW conguration and
up to ve minutes in the 90 kW
conguration.
Liebert® APM from 30 - 150 kW
1
0
0
%
k
V
A
1
0
0
%
k
V
A
%
100
80
60
40
20
0
20
40
60
80
100
Cos φ 0.6
Cos φ 0.5
kVAr
Leading
Lagging
Cos φ 0.8
Cos φ 0.8
Cos φ 0.9
Cos φ 0.9
25 50 75
Cos φ 0.5
100 % kW
Cos φ 1
Liebert® APM - output power factor diagram
5
Enhanced Active Power
With its unitary output power
factor (kVA=kW), Liebert® APM
offers an increased level of active
power to support mission- critical
loads.
The added advantage of increased
active power allows customers to
select the most appropriate rating
for their critical application, sizing
the system based on the actual
active power requirements, thus
minimizing the initial investment
and maximizing TCO.
Liebert® APM provides enhanced
exibility to ensure superior
protection for all load types
(lagging or leading) without
derating.
Liebert® APM - efciency curve
27kW
24kW
21kW
18kW
0.9 Lead
0.8 Lead
0.7 Lead
0.6 Lead
15kW0.5 Lead
0.9 Lag
0.8 Lag
0.7 Lag
0.6 Lag
0.5 Lag
12kW
9kW
30kW
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
97%
96%
95%
94%
93%
92%
91%
90%
89%
88%
87%
86%
85%
Load%
Efficiency
30° 35° 40° Traditional 0.8 PF rated UPS
Ideal
Efficiency
Efciency
The Liebert® APM is capable of
reaching the industry’s highest
efciency level of up to 96% in true
online double conversion mode.
With its at efciency curve - the
Liebert® APM delivers maximum
efciency regardless of the load
level. It is capable of achieving
an efciency above 95% from
full load down to 30% as well as
maintaining an efciency above
94% down to 20% load. This level
of operating efciency results in
signicant cost savings while at
the same time contributing to
reducing the carbon footprint of
the installation and optimizing
power usage effectiveness (PUE).
Furthermore, whenever the input
conditions and load nature allow,
Liebert® APM is further able to
increase efciency to above 98%
by operating in Eco mode.
Efciently Protecting Mission-Critical Loads
6
The modular architecture of the Liebert® APM allows single unit capacity
to be scaled up to a maximum of 150 kW without impacting on the
system footprint or modifying the installation layout.
Increases in capacity and redundancy can be made both vertically and
horizontally by adding 30 kW power modules to an existing rack or,
alternatively by connecting up to four complete UPS systems in parallel in
order to reach a maximum of 600 kW of active power.
Parallel and Dual Bus Ready
Liebert® APM can be connected with up to four units in parallel. A single
unit can be set up to work in parallel through the use of a communication
cable set, allowing the system to be customized for the required
conguration. Additionally, Liebert® APM allows easy deployment of Tier 4
architecture through its integrated dual bus control.
Modular, Scalable Conguration
Dual Bus Configuration
Source One Source Two
Paralleling
Signal Cable
Dual
Bus
Signal
Cable
Critical load #1
Critical load #2
STS
STS
Single
Critical load
Configuration 1+N
Critical load
Dual Bus Configuration
Source One Source Two
Paralleling
Signal Cable
Dual
Bus
Signal
Cable
Critical load #1
Critical load #2
STS
STS
Single
Critical load
Configuration 1+N
Critical load
Dual Bus Configuration
Source One Source Two
Paralleling
Signal Cable
Dual
Bus
Signal
Cable
Critical load #1
Critical load #2
STS
STS
Single
Critical load
Configuration 1+N
Critical load
Liebert® APM - parallel and dual bus congurations
Flexible Battery Conguration
The exible battery conguration
of the Liebert® APM is designed
to meet individual installation
availability and back up time
requirements.
Liebert® APM is compatible with
numerous battery congurations
including internal and external
modular solutions, as well as
traditional external battery banks
with string lengths between 30
and 40 batteries.
In a parallel system batteries can
be installed in a common bank
to maximize cost effectiveness
and minimize oor space.
Alternatively, a single battery
bank can be dedicated to each
UPS, delivering full redundancy
and avoiding the possibility of a
single point of failure.
Extended battery life is further
ensured through a temperature
compensated charging algorithm
which prevents battery damage,
thus prolonging lifespan.
30 kW+30 kW redundancy
15’ back up time
90 kW+30 kW redundancy
15’ back up time
120 kW+30 kW redundancy
15’ back up time
60 kW+30 kW redundancy
15’ back up time
7
Communication
Liebert® APM features a large
multi-lingual LCD display giving
users access to key operating
information including alarm
status, conguration, start-up/
shutdown, transfer and advanced
metering.
The micro-processor based display
functions independently from
the system control and provides
access to:
• real-time meter readings of
system currents, voltages,
active and reactive power
• status reports and history les
• system power ow one-line
diagram
Liebert® APM also offers
communication features through
Web (HTTP), Modbus and SNMP
protocol.
Software Connectivity
Liebert® Nform™ network
communications system enables
customers to leverage the
distributed monitoring capabilities
of network connected equipment
for providing centralized
management of distributed
systems.
Liebert® SiteScan is a centralized
site monitoring system which
ensures maximum visibility and
availability of critical operations.
Liebert® SiteScan Web allows
users to monitor and control
virtually any piece of critical
support equipment. Its features
include real-time monitoring
and control, data analysis,
trend reporting, and event
management.
Serviceability and
Maintainability
The Liebert® APM is designed to
facilitate effortless installation
and simplify service with its
easy to remove power modules.
The hot-swappable module-
based architecture considerably
decreases the mean time to
repair (MTTR) and facilitates
maintenance operations by
allowing single modules to be
serviced while the remaining
modules continue to power the
load.
All power modules and critical
components are easily accessible
from the front of the unit.
Trellis™ Platform
Emerson Network Power’s
Trellis™ platform is a real-time
infrastructure optimization
platform that enables the unied
management of data centre IT
and facilities infrastructure.
The Trellis™ platform software
can manage capacity, track
inventory, plan changes, visualize
congurations, analyze and
calculate energy usage, and
optimize cooling and power
equipment as well as enable for
virtualization.
The Trellis™ platform monitors
the data center, providing a
thorough understanding of
system dependencies to help IT
and facilities organizations keep
the data center running at peak
performance. This unied and
complete solution, delivers the
power to see the real situation in
your data center, make the right
decision and take action with
condence.
In The Field
8
Servicing Critical Infrastructure
Maximize Availability
Minimize Downtime
Reduce Operating Costs
Proactive equipment maintenance reduces downtime and extends equipment life which in turn maximizes
return on investment and increases system availability. Emerson Network Power supports entire critical
infrastructures with an extensive service offering, guaranteeing network availability and total peace of mind
24/7.
Our approach to servicing critical infrastructure covers all aspects of availability and performance, from
single units to entire mission critical systems, providing customers with tailored services to meet their
individual business needs and further guaranteeing Business-Critical Continuity™.
Emerson Network Power’s service program is designed to ensure that your critical power protection
system is maintained in an optimum state of readiness at all times.
The LIFE™.net remote monitoring and diagnostic service provides early warning of UPS conditions and out of
tolerances. This allows effective proactive maintenance, fast incident response and remote trouble shooting,
giving customers complete security and peace of mind.
Pre-Emptive Maintenance
Regular preventive maintenance increases uptime. Emerson Network Power’s LIFE™.
net provides early warning of operating anomalies allowing real-time diagnosis and
swift identication and resolution.
Immediate Identication of Problems
Should an emergency condition arise, an engineer in the 24/7 manned LIFE™.net
service center carries out an immediate fault analysis and instigates appropriate
corrective action.
Superior Asset Management
Through comprehensive data collection and analysis, LIFE™.net’s detailed reporting
system provides valuable information on power and equipment trends,
over any selected period of time.
9
Technical Characteristics
Power (kVA) 30 60 90 120 150
Power (kW) 30 60 90 120 150
System Efciency
AC - AC on-line double conversion efciency (%) Between 95% and 96% for load >30%
AC - AC Eco mode efciency (%) >98%
Input Parameters
Rated input voltage 380/400/415 VAC, three-phase four-wire
Rated operating frequency (Hz) 50/60Hz
Input voltage range (Hz) 477V - 305V at full load, 477V - 228V at 70% load
Input frequency range 40Hz - 70Hz
Input power factor >0 .99 at full load, >0.98 at half load
Input THDI (%) <5%
DC Parameters
Battery number 30,32,34,36,38,40
Battery Compensation Yes
Maximum runtime with internal battery 30’ 10’ 5’ N/A N/A
DC ripple current ≤0.05C10
Output Parameter
Inverter output voltage 380/400/415 VAC, three-phase four-wire
Inverter output frequency (Hz) 50/60Hz
Output frequency stability (Hz) 50Hz/60Hz±0.02%
Voltage stability in steady state ±1%
Voltage stability in transient state Complies with IEC/EN 62040-3, class 1
Inverter overload capacity 1 hour for 105%, 10 mins for 125%, 1 min for 150%, 200ms for >150%
Phase Shift
With 100% balanced load <1°
With 100% unbalanced load <1.5°
THDv
100% linear load <1
100% non-linear load <4
Bypass Parameter
Bypass input voltage 380/400/415 VAC, three-phase four-wire
Bypass voltage range settable through software Default: -20% to + 15%, other values, such as -40%, -30%, -10% to + 10%, +15%
Bypass overload capacity 135% long term, 170% for 1 hour, 1000% for 100ms
Environmental Conditions
Operating temperature range (˚C) 0 - 40˚C*
Storage temperature (˚C) -25 to 70˚C
Maximum Operating altitude ≤1 000m, when operating at 1000>2000m, derated by 1% for every 100 m increase of altitude
Relative Humidity ≤95%
Noise (1m) 52 - 62 dBA, adjusted according to load rate and number of modules
Protection Level IP20
Standards
Low Voltage Directive 2006/95/EC with the Amendment Directive 93/68/EEC Directive for electromagnetic compatibility 2004/108/EC
General and safety requirements for UPS used in operator access areas IEC/EN 62040-1:2008
Electromagnetic compatibility (EMC) requirements for UPS IEC/EN 62040-2: Immunity category C2, Emission category C2
Dimensions and Weight
Dimension, w x h x d (mm) 600x1996x1100 mm
Weight (kg) 280 315 350 385 420
* conditions apply
Liebert® APM
Specications
10
Emerson Network Power Business-Critical ContinuityTM Expert
Today’s successful businesses depend on adaptable technologies to help them respond quickly
to market demands. Your data center must be built on a support infrastructure designed to
match the power and cooling needs of rapidly changing IT initiatives such as virtualization and
consolidation. Each IT change, move or addition will affect the entire support infrastructure
so you need products and support that ensure your IT systems will operate reliably in these
environments.
www.EmersonNetworkPower.eu
11
More than 35,000 organizations in 70 countries
depend on our Business - Critical ContinuityTM Promise:
your IT infrastructure stays up to support your
Business!
Ensuring The High Availability
Of Mission-Critical Data And Applications.
Emerson Network Power
The global leader in enabling Business-Critical Continuity™. EmersonNetworkPower.eu
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Infrastructure Management & Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Locations
Emerson Network Power
Via Leonardo Da Vinci 16/18
Zona Industriale Tognana
35028 Piove di Sacco (PD) Italy
Tel: +39 049 9719 111
Fax: +39 049 5841 257
Via Fornace, 30
40023 Castel Guelfo (BO) Italy
Tel: +39 0542 632 111
Fax: +39 0542 632 120
Marketing.NetworkPower.Emea@Emerson.com
United States
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Tel: +1 614 8880246
Asia
7/F, Dah Sing Financial Centre
108 Gloucester Road, Wanchai
Hong Kong
Tel: +852 2572220
Fax: +852 28029250
Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its afliated companies. ©2013 Emerson Electric Co.
About Emerson Network Power
Emerson Network Power, a business of Emerson (NYSE:EMR),
delivers software, hardware and services that maximize availability,
capacity and efciency for data centers, healthcare and industrial
facilities. A trusted industry leader in smart infrastructure
technologies, Emerson Network Power provides innovative data
center infrastructure management solutions that bridge the gap
between IT and facility management and deliver efciency and
uncompromised availability regardless of capacity demands. Our
solutions are supported globally by local Emerson Network Power
service technicians. Learn more about Emerson Network Power
products and services at
www.EmersonNetworkPower.eu
While every precaution has been taken to ensure accuracy and completeness
herein, Emerson assumes no responsibility, and disclaims all liability, for
damages resulting from use of this information or for any errors or omissions.
Specications subject to change without notice.
MKA4L0UKAPM Rev.2-05/2013