APC 3000VA Filter - Marine User Manual
Displayed below is the user manual for 3000VA Filter - Marine by APC which is a product in the Uninterruptible Power Supplies (UPSs) category. This manual has pages.
Related Manuals
Addendum
SUR T/SURTD XLIM Pr oducts
Overview
The information in this addendum is for DNV certified SURT/SURTD XLIM UPS models and companion
EMI filters.
The APC UPS models listed in the table below meet DNV 2.4 Type Approval for Bridge, Control Room, and
Accomodation Zone s, wh en used with the appropriate companion filter. Compani on filter models are listed in
the ta ble below.
In addition to the standard pro duct i nventor y the fol lowing items will be included:
• Rail Kit
• Rack-Mount Hardware
• EPO Ferrite Bead
(SURTD2200XL IM/SURTD3000XLIM/SURT6000XLIM models only)
• One ground cable
UPS Model Filter Model
SURT1000XLIM SURT023M
SURTD2200XLIM SURT023M
SURTD3000XLIM SURT023M
SURT6000XLIM SURT024M
Addendum SURT/SURTD XLIM 2
Specifications
When the APC UPS models lis ted in the table above are use d w ith th e appropriate co mpanion fi lter the
specifications in thi s ad dendum supers ede the specif ications in the UPS user manua ls for the standard
SURT/SURTD produ cts.
Expe cted batte r y life drop s by 50% for every 10º increa se in the ambient te mper atures
above 25° C (77º F ).
Temperature
Operation
0º C to 40º C (32º F to 104º F) a t 100% rated output power
40 º C to 55º C (104º F to 131º F) derat e output power 2.5%/º C (1 .38%/º F)
Avoid operat ing this pr oduct at temperatures above 40º C (104º F).
Storage
0º C to 55º C (32º F to 131º F)
Maxim um recommended storage temperature 35º C (95º F)
Charge t he battery pe riodically to prevent permanent operating capacity loss. Charge frequency
requirements are de pendent on storage tempe rature. Batteries will cha r ge in 48 hours while the
UPS op e r at es o n AC pow er.
25º C (77º F) charge the batter y eve r y 12 months
30º C (86º F) charge the battery every 8 months
40º C (104º F) ch arge t he battery ev ery 4 mo nths
Beeper Signals An audible signal will accompany some LED indicator activity. Thi s a udible signal is not
cons idered an audible warning or al arm .
Safety
Certification
CE
DNV Certifi ca tion 2.4 Type Appro val, Bridge & Deck Zones
For DNV type approval certificate go to the APC Web site, www.apc.com.
Compass Safe
Distance per
IEC 60945
SURT 1000XLIM: 140 cm
SURT D2200XLIM/SURTD3000XLIM: 210 cm
SIURT6 000XLIM: 174 cm
Addendum SURT/SURTD XLIM 3
Installation
Rack-Mount
The cle ats will be fact ory install ed on some units.
The UPS is heavy. Remove the batteries before installing the UPS.
Refer to the UPS user manual for battery re mov al and battery install ation inst ructi ons.
Install the marine filter, the UPS, and the XLBP(s ) at or ne ar the bottom of the rack. Place the mar ine
filter above the UPS. Place the marine filter, and the UPS above the XLBP(s).
SURT1000XLIM models:
4
4
4
1 pair rack-mount brac kets
1 pair rai l cleats
suo0721a
suo0722a
Addendum SURT/SURTD XLIM 4
8842
1 pair rac k-mo unt brackets 1 pair rail cleats
suo0723a
suo0725a
suo0724a
Addendum SURT/SURTD XLIM 5
Connect the Emergency Power Off (optional)
The location of the emergency power off (EP O) switch may vary from the position dep icted in the
graphic below.
Wh er e a p pr o p r ia te, in stal l an E PO s w i tc h.
W ith installations ut ilizing a filter in compliance with DNV 2.4 req uirements, the supplied ferrite bea d must be
installed with the EPO feature.
Cap tur e eight loop s of wire when inst alling the fe r r ite bead. Ref er to the diagr am below.
suo0729a
Customer supp ort and warranty in formatio n is available at the APC Web site , www.apc.com.
© 2011 APC by Schneider Electric. APC, the APC logo, an d Smart-UPS ar e ow ned by Schneider
Electric Industri es S.A.S., A merican Power Conversion Corporation, or their affiliated companies.
Al l other trademarks are property of their respective owners. 990-3907B
06/2011