Table of Contents
- Dell PowerEdge T320 Systems Owner's Manual
- About Your System
- Front-Panel Features And Indicators—Tower Mode
- Front-Panel Features And Indicators—Rack Mode
- LCD Panel Features
- Diagnostic Indicators
- Hard-Drive Indicator Patterns
- Back-Panel Features And Indicators
- NIC Indicator Codes
- Power Indicator Codes For Redundant Power Supply
- Power Indicator Codes For Non-Redundant Power Supply
- Other Information You May Need
- Using The System Setup And Boot Manager
- Installing System Components
- Recommended Tools
- Front Bezel (Optional)
- System Feet—Tower Mode
- Wheel Assembly (Optional)—Tower Mode
- Opening And Closing The System
- Inside The System
- Optical Drives And Tape Drives (Optional)
- Cooling Shroud
- Hard Drives—Hot-Swappable
- Removing A Hot-Swap Hard Drive
- Installing A Hot-Swap Hard Drive
- Removing A 2.5 Inch Hard-Drive Blank
- Installing A 2.5 Inch Hard-Drive Blank
- Removing A 3.5 Inch Hard-Drive Blank
- Installing A 3.5 Inch Hard-Drive Blank
- Removing A 2.5 Inch Hard Drive From A 3.5 Inch Hard-Drive Adapter
- Installing A 2.5 Inch Hard Drive Into A 3.5 Inch Hard-Drive Adapter
- Removing A Hard Drive Or A Hard-Drive Adapter From A Hard-Drive Carrier
- Installing A Hard Drive Or A Hard-Drive Adapter Into A Hard-Drive Carrier
- Hard Drives—Cabled
- Hard-Drive Backplane
- Four-Slot Hard-Drive Blank
- System Memory
- Cooling Fans
- Internal USB Memory Key (Optional)
- PCIe Card Holder (Optional)
- Expansion Cards
- iDRAC Ports Card
- Internal Dual SD Module
- Internal SD Card
- Processors
- Redundant AC Power Supply
- Non-Redundant AC Power Supply
- Power Distribution Board And Power Interposer Board
- System Battery
- Control-Panel Assembly
- Removing The Control-Panel Assembly
- Installing The Control-Panel Assembly
- Removing The Control Panel
- Installing The Control Panel
- Removing The Control-Panel Board For Systems With LCD Modules
- Installing The Control-Panel Board For Systems With LCD Modules
- Removing The Control-Panel Board For Systems With Diagnostic Indicators
- Installing The Control-Panel Board For Systems With Diagnostic Indicators
- Removing The LCD Module
- Installing The LCD Module
- Removing The VGA Module—Rack Mode
- Installing The VGA Module—Rack Mode
- System Board
- Converting The System From Tower Mode To Rack Mode
- Troubleshooting Your System
- Safety First—For You And Your System
- Troubleshooting System Startup Failure
- Troubleshooting External Connections
- Troubleshooting The Video Subsystem
- Troubleshooting A USB Device
- Troubleshooting A Serial I/O Device
- Troubleshooting A NIC
- Troubleshooting A Wet System
- Troubleshooting A Damaged System
- Troubleshooting The System Battery
- Troubleshooting A Non-Redundant Power Supply
- Troubleshooting Redundant Power Supplies
- Troubleshooting Cooling Problems
- Troubleshooting Cooling Fans
- Troubleshooting System Memory
- Troubleshooting An Internal USB Key
- Troubleshooting An SD Card
- Troubleshooting An Optical Or Tape Drive
- Troubleshooting A Hard Drive
- Troubleshooting Expansion Cards
- Troubleshooting Processor
- Using System Diagnostics
- Jumpers And Connectors
- Technical Specifications
- System Messages
- Getting Help
DELL T320 User Manual
Displayed below is the user manual for T320 by DELL which is a product in the Servers category. This manual has pages.
Related Manuals
Dell PowerEdge T320 Systems
Owner's Manual
Regulatory Model: E20S Series
Regulatory Type: E20S001
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the
problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2013 Dell Inc. All Rights Reserved.
Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™,
PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™, Venue™ and Vostro™ are trademarks
of Dell Inc. Intel®, Pentium®, Xeon®, Core® and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries.
AMD® is a registered trademark and AMD Opteron™, AMD Phenom™ and AMD Sempron™ are trademarks of Advanced Micro
Devices, Inc. Microsoft®, Windows®, Windows Server®, Internet Explorer®, MS-DOS®, Windows Vista® and Active Directory® are
either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat® and
Red Hat® Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® and SUSE®
are registered trademarks of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle
Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix
Systems, Inc. in the United States and/or other countries. VMware®, vMotion®, vCenter®, vCenter SRM™ and vSphere® are registered
trademarks or trademarks of VMware, Inc. in the United States or other countries. IBM® is a registered trademark of International
Business Machines Corporation.
2013 - 11
Rev. A04
Contents
1 About Your System......................................................................................................................9
Front-Panel Features And Indicators—Tower Mode...............................................................................................9
Front-Panel Features And Indicators—Rack Mode...............................................................................................14
LCD Panel Features.................................................................................................................................................15
Home Screen....................................................................................................................................................16
Setup Menu......................................................................................................................................................16
View Menu....................................................................................................................................................... 17
Diagnostic Indicators..............................................................................................................................................17
Hard-Drive Indicator Patterns................................................................................................................................ 19
Back-Panel Features And Indicators..................................................................................................................... 20
NIC Indicator Codes................................................................................................................................................22
Power Indicator Codes For Redundant Power Supply...........................................................................................22
Power Indicator Codes For Non-Redundant Power Supply...................................................................................23
Other Information You May Need...........................................................................................................................24
2 Using The System Setup And Boot Manager.......................................................................25
Choosing The System Boot Mode.......................................................................................................................... 25
Entering System Setup............................................................................................................................................26
Responding To Error Messages.......................................................................................................................26
Using The System Setup Navigation Keys.......................................................................................................26
System Setup Options.............................................................................................................................................27
System Setup Main Screen..............................................................................................................................27
System BIOS Screen........................................................................................................................................27
System Information Screen..............................................................................................................................27
Memory Settings Screen................................................................................................................................. 28
Processor Settings Screen.............................................................................................................................. 28
SATA Settings Screen......................................................................................................................................30
Boot Settings Screen....................................................................................................................................... 30
Integrated Devices Screen.............................................................................................................................. 31
Serial Communications Screen........................................................................................................................31
System Profile Settings Screen........................................................................................................................32
System Security Screen...................................................................................................................................33
Miscellaneous Settings....................................................................................................................................34
System And Setup Password Features.................................................................................................................. 34
Assigning A System And/Or Setup Password..................................................................................................35
Deleting Or Changing An Existing System And/Or Setup Password................................................................35
Using Your System Password To Secure Your System....................................................................................36
Operating With A Setup Password Enabled.................................................................................................... 36
Entering The UEFI Boot Manager...........................................................................................................................36
Using The Boot Manager Navigation Keys......................................................................................................37
Boot Manager Screen......................................................................................................................................37
UEFI Boot Menu............................................................................................................................................... 38
Embedded System Management............................................................................................................................38
iDRAC Settings Utility..............................................................................................................................................38
Entering The iDRAC Settings Utility..................................................................................................................38
Changing The Thermal Settings.......................................................................................................................38
3 Installing System Components................................................................................................41
Recommended Tools.............................................................................................................................................. 41
Front Bezel (Optional)............................................................................................................................................. 41
Installing The Front Bezel.................................................................................................................................41
Removing The Front Bezel................................................................................................................................42
System Feet—Tower Mode....................................................................................................................................42
Removing The System Feet..............................................................................................................................43
Installing The System Feet............................................................................................................................... 43
Wheel Assembly (Optional)—Tower Mode............................................................................................................43
Removing The Wheel Assembly.......................................................................................................................44
Installing The Wheel Assembly........................................................................................................................45
Opening And Closing The System...........................................................................................................................45
Opening The System........................................................................................................................................ 45
Closing The System..........................................................................................................................................46
Inside The System...................................................................................................................................................46
Optical Drives And Tape Drives (Optional).............................................................................................................48
Removing The Optical Drive Or Tape Drive......................................................................................................49
Installing The Optical Drive Or Tape Drive.......................................................................................................52
Cooling Shroud....................................................................................................................................................... 52
Removing The Cooling Shroud.........................................................................................................................52
Installing The Cooling Shroud.......................................................................................................................... 53
Hard Drives—Hot-Swappable ...............................................................................................................................54
Removing A Hot-Swap Hard Drive...................................................................................................................54
Installing A Hot-Swap Hard Drive.................................................................................................................... 55
Removing A 2.5 Inch Hard-Drive Blank............................................................................................................56
Installing A 2.5 Inch Hard-Drive Blank............................................................................................................. 56
Removing A 3.5 Inch Hard-Drive Blank............................................................................................................56
Installing A 3.5 Inch Hard-Drive Blank............................................................................................................. 57
Removing A 2.5 Inch Hard Drive From A 3.5 Inch Hard-Drive Adapter............................................................57
Installing A 2.5 Inch Hard Drive Into A 3.5 Inch Hard-Drive Adapter...............................................................58
Removing A Hard Drive Or A Hard-Drive Adapter From A Hard-Drive Carrier................................................ 58
Installing A Hard Drive Or A Hard-Drive Adapter Into A Hard-Drive Carrier...................................................59
Hard Drives—Cabled..............................................................................................................................................59
Removing The Internal Hard-Drive Bay........................................................................................................... 60
Installing The Internal Hard-Drive Bay.............................................................................................................61
Removing A Cabled Hard Drive........................................................................................................................61
Installing A Cabled Hard Drive.........................................................................................................................62
Hard-Drive Backplane............................................................................................................................................ 63
Removing The Hard-Drive Backplane..............................................................................................................63
Installing The Hard-Drive Backplane...............................................................................................................69
Four-Slot Hard-Drive Blank.....................................................................................................................................70
Removing A Four-Slot Hard-Drive Blank..........................................................................................................70
Installing A Four-Slot Hard-Drive Blank...........................................................................................................71
System Memory......................................................................................................................................................71
General Memory Module Installation Guidelines............................................................................................ 73
Mode-Specific Guidelines................................................................................................................................73
Sample Memory Configurations.......................................................................................................................74
Removing Memory Modules............................................................................................................................ 75
Installing Memory Modules............................................................................................................................. 76
Cooling Fans............................................................................................................................................................78
Removing The Internal Cooling Fan................................................................................................................. 78
Installing The Internal Cooling Fan...................................................................................................................80
Removing The External Cooling Fan ................................................................................................................80
Installing The External Cooling Fan..................................................................................................................82
Internal USB Memory Key (Optional)..................................................................................................................... 82
Replacing The Internal USB Key......................................................................................................................83
PCIe Card Holder (Optional)....................................................................................................................................84
Removing The PCIe Card Holder......................................................................................................................84
Installing The PCIe Card Holder.......................................................................................................................85
Expansion Cards..................................................................................................................................................... 85
Expansion Card Installation Guidelines............................................................................................................85
GPU Card Installation Guidelines.....................................................................................................................86
Removing An Expansion Card.......................................................................................................................... 86
Installing An Expansion Card........................................................................................................................... 87
Removing A GPU Card......................................................................................................................................88
Installing A GPU Card.......................................................................................................................................89
iDRAC Ports Card....................................................................................................................................................90
Removing The iDRAC Ports Card......................................................................................................................90
Installing The iDRAC Ports Card.......................................................................................................................91
Replacing An SD vFlash Card...........................................................................................................................92
Internal Dual SD Module........................................................................................................................................ 92
Removing An Internal Dual SD Module............................................................................................................92
Installing An Internal Dual SD Module.............................................................................................................93
Internal SD Card..................................................................................................................................................... 94
Removing An Internal SD Card.........................................................................................................................94
Installing An Internal SD Card..........................................................................................................................94
Processors..............................................................................................................................................................95
Removing A Processor.....................................................................................................................................95
Installing A Processor......................................................................................................................................97
Redundant AC Power Supply..................................................................................................................................98
Removing A Redundant AC Power Supply.......................................................................................................98
Installing A Redundant AC Power Supply........................................................................................................99
Removing The Power Supply Blank............................................................................................................... 100
Installing The Power Supply Blank................................................................................................................ 100
Replacing The Power Supply Divider.............................................................................................................101
Non-Redundant AC Power Supply .......................................................................................................................102
Removing A Non-Redundant AC Power Supply.............................................................................................102
Installing A Non-Redundant AC Power Supply..............................................................................................104
Power Distribution Board And Power Interposer Board......................................................................................104
Removing The Power Interposer Board.........................................................................................................104
Installing The Power Interposer Board..........................................................................................................106
Replacing The Power Distribution Board.......................................................................................................106
System Battery..................................................................................................................................................... 106
Replacing The System Battery.......................................................................................................................106
Control-Panel Assembly....................................................................................................................................... 107
Removing The Control-Panel Assembly.........................................................................................................108
Installing The Control-Panel Assembly..........................................................................................................111
Removing The Control Panel..........................................................................................................................111
Installing The Control Panel........................................................................................................................... 113
Removing The Control-Panel Board For Systems With LCD Modules...........................................................113
Installing The Control-Panel Board For Systems With LCD Modules............................................................114
Removing The Control-Panel Board For Systems With Diagnostic Indicators..............................................115
Installing The Control-Panel Board For Systems With Diagnostic Indicators...............................................116
Removing The LCD Module............................................................................................................................116
Installing The LCD Module............................................................................................................................. 117
Removing The VGA Module—Rack Mode.....................................................................................................118
Installing The VGA Module—Rack Mode......................................................................................................119
System Board........................................................................................................................................................119
Removing The System Board.........................................................................................................................119
Installing The System Board.......................................................................................................................... 120
4 Converting The System From Tower Mode To Rack Mode............................................. 123
Safety Instructions................................................................................................................................................123
Preparing A System For Conversion From Tower Mode To Rack Mode..............................................................123
Rack Installation................................................................................................................................................... 125
5 Troubleshooting Your System...............................................................................................127
Safety First—For You And Your System............................................................................................................... 127
Troubleshooting System Startup Failure.............................................................................................................. 127
Troubleshooting External Connections.................................................................................................................127
Troubleshooting The Video Subsystem................................................................................................................127
Troubleshooting A USB Device............................................................................................................................ 127
Troubleshooting A Serial I/O Device.................................................................................................................... 128
Troubleshooting A NIC..........................................................................................................................................128
Troubleshooting A Wet System............................................................................................................................129
Troubleshooting A Damaged System................................................................................................................... 129
Troubleshooting The System Battery................................................................................................................... 130
Troubleshooting A Non-Redundant Power Supply...............................................................................................130
Troubleshooting Redundant Power Supplies.......................................................................................................131
Troubleshooting Cooling Problems.......................................................................................................................131
Troubleshooting Cooling Fans.............................................................................................................................. 131
Troubleshooting System Memory.........................................................................................................................131
Troubleshooting An Internal USB Key..................................................................................................................132
Troubleshooting An SD Card................................................................................................................................ 133
Troubleshooting An Optical Or Tape Drive...........................................................................................................133
Troubleshooting A Hard Drive.............................................................................................................................. 134
Troubleshooting Expansion Cards........................................................................................................................134
Troubleshooting Processor.................................................................................................................................. 135
6 Using System Diagnostics.....................................................................................................137
Dell Online Diagnostics.........................................................................................................................................137
Dell Embedded System Diagnostics.....................................................................................................................137
When To Use The Embedded System Diagnostics........................................................................................137
Running The Embedded System Diagnostics.................................................................................................137
System Diagnostic Controls........................................................................................................................... 138
7 Jumpers And Connectors......................................................................................................139
System Board Jumper Settings............................................................................................................................139
System Board Connectors....................................................................................................................................140
Disabling A Forgotten Password.......................................................................................................................... 141
8 Technical Specifications....................................................................................................... 143
9 System Messages...................................................................................................................149
LCD Messages......................................................................................................................................................149
Viewing LCD Messages................................................................................................................................. 149
Removing LCD Messages...............................................................................................................................149
System Error Messages........................................................................................................................................149
Warning Messages...............................................................................................................................................165
Diagnostic Messages...........................................................................................................................................165
Alert Messages.....................................................................................................................................................165
10 Getting Help............................................................................................................................167
Contacting Dell..................................................................................................................................................... 167
1
About Your System
Front-Panel Features And Indicators—Tower Mode
Figure 1. Front-Panel Features and Indicators—2.5 Inch Hot-Swappable Hard-Drive Chassis
9
Figure 2. Front-Panel Features and Indicators—3.5 Inch Hot-Swappable Hard-Drive Chassis
Item Indicator, Button, or
Connector Icon Description
1 Tape drive (optional) One optional 5.25 inch tape drive.
NOTE: If your system is installed with a double-width
GPU card, the system supports only one 5.25 inch
removable media storage device.
2 Optical drive 2 (optional) Up to two optional SATA DVD-ROM drive or DVD+/-RW
drive.
NOTE: If your system is installed with a double-width
GPU card, the system supports only one 5.25 inch
removable media storage device.
3 Optical drive 1 (optional)
10
Item Indicator, Button, or
Connector Icon Description
4 Power-on indicator, power
button
The power-on indicator lights when the system power is
on. The power button controls the power supply output to
the system.
NOTE: On Advanced Configuration and Power
Interface (ACPI)-compliant operating systems,
turning off the system using the power button causes
the system to perform a graceful shutdown before
power to the system is turned off.
5 NMI button Used to troubleshoot software and device driver errors
when running certain operating systems. This button can
be pressed using the end of a paper clip.
Use this button only if directed to do so by qualified
support personnel or by the operating system
documentation.
6 System identification button The identification buttons on the front and back panels of
the system can be used to locate a particular system
within a rack. When one of these buttons is pressed, the
LCD panel on the front and the system status indicator on
the back flash until one of the buttons is pressed again.
Press to toggle the system ID on and off.
If the system stops responding during POST, press and
hold the system ID button for more than five seconds to
enter BIOS progress mode.
To reset integrated Dell Remote Access Controller
(iDRAC) (if not disabled in F2 iDRAC setup), press and hold
for more than 15 seconds.
7 LCD menu buttons Allow you to navigate the control panel LCD menu.
8 Information tag A slide-out label panel which allows you to record system
information such as Service Tag, NIC, MAC address, and
so on.
9 LCD panel Displays system ID, status information, and system error
messages. The LCD lights blue during normal system
operation. The LCD lights amber when the system needs
attention, and displays an error code followed by
descriptive text.
NOTE: If the system is connected to a power source
and an error is detected, the LCD lights amber
regardless of whether the system is turned on or off.
10 USB connectors (2) Allow you to connect USB devices to the system. The
ports are USB 2.0-compliant.
11 Hard drives Your system supports one of the following configurations:
• Up to eight 3.5 inch hot-swappable hard drives
• Up to eight 2.5 inch hot-swappable hard drives
installed in the 3.5 inch hard-drive carriers
11
Item Indicator, Button, or
Connector Icon Description
• Up to sixteen 2.5 inch hot-swappable hard drives
Figure 3. Front-Panel Features and Indicators—3.5 Inch Cabled Hard-Drive Chassis
NOTE: Cabled hard-drive systems are not rackable.
Item Indicator, Button, or
Connector Icon Description
1 Tape drive (optional) One optional 5.25 inch tape drive.
2 Optical drive (optional) One optional SATA DVD-ROM drive or DVD+/-RW drive.
12
Item Indicator, Button, or
Connector Icon Description
3 Power-on indicator, power
button
The power-on indicator lights when the system power is
on. The power button controls the power supply output to
the system.
NOTE: On ACPI-compliant operating systems, turning
off the system using the power button causes the
system to perform a graceful shutdown before power
to the system is turned off.
4 NMI button Used to troubleshoot software and device driver errors
when running certain operating systems. This button can
be pressed using the end of a paper clip.
Use this button only if directed to do so by qualified
support personnel or by the operating system
documentation.
5 System identification button The identification buttons on the front and back panels of
the system can be used to locate a particular system
within a rack. When one of these buttons is pressed, the
LCD panel on the front chassis and the system status
indicator on the back chassis flash until one of the buttons
is pressed again.
Press to toggle the system ID on and off.
If the system stops responding during POST, press and
hold the system ID button for more than five seconds to
enter BIOS progress mode.
To reset iDRAC (if not disabled in F2 iDRAC setup), press
and hold for more than 15 seconds.
6 Information tag A slide-out label panel which allows you to record system
information such as Service Tag, NIC, MAC address, and
so on.
7 Diagnostic indicators The diagnostic indicators light up to display error status.
8 USB connectors (2) Allow you to connect USB devices to the system. The
ports are USB 2.0-compliant.
13
Front-Panel Features And Indicators—Rack Mode
Figure 4. Front-Panel Features and Indicators
NOTE: Only systems with hot-swappable hard drives are rackable.
Item Indicator, Button, or
Connector Icon Description
1 Power-on indicator, power
button
The power-on indicator lights when the system power is
on. The power button controls the power supply output to
the system.
NOTE: On ACPI-compliant operating systems, turning
off the system using the power button causes the
system to perform a graceful shutdown before power
to the system is turned off.
2 NMI button Used to troubleshoot software and device driver errors
when running certain operating systems. This button can
be pressed using the end of a paper clip.
Use this button only if directed to do so by qualified
support personnel or by the operating system
documentation.
3 System identification button The identification buttons on the front and back panels
can be used to locate a particular system within a rack.
When one of these buttons is pressed, the LCD panel on
the front and the system status indicator on the back flash
until one of the buttons is pressed again.
Press to toggle the system ID on and off.
If the system stops responding during POST, press and
hold the system ID button for more than five seconds to
enter BIOS progress mode.
To reset iDRAC (if not disabled in F2 iDRAC setup) press
and hold for more than 15 seconds.
14
Item Indicator, Button, or
Connector Icon Description
4 LCD menu buttons Allow you to navigate the control panel LCD menu.
5 Information tag A slide-out label panel which allows you to record system
information such as Service Tag, NIC, MAC address, and
so on.
6 LCD panel Displays system ID, status information, and system error
messages. The LCD lights blue during normal system
operation. The LCD lights amber when the system needs
attention, and the LCD panel displays an error code
followed by descriptive text.
NOTE: If the system is connected to a power source
and an error is detected, the LCD lights amber
regardless of whether the system is turned on or off.
7 Video connector Allows you to connect a VGA display to the system.
8 USB connectors (2) Allow you to connect USB devices to the system. The
ports are USB 2.0-compliant.
9 Optical drive 1 (optional) Up to two optional SATA DVD-ROM drive or DVD+/-RW
drive.
NOTE: If your system is installed with a double-width
GPU card, the system supports only one 5.25 inch
removable media storage device.
10 Optical drive 2 (optional)
11 Tape drive (optional) One 5.25 inch optional tape drive.
NOTE: If your system is installed with a double-width
GPU card, the system supports only one 5.25 inch
removable media storage device.
12 Hard drives Your system supports one of the following configurations:
• Up to eight 3.5 inch hot-swappable hard drives.
• Up to eight 2.5 inch hot-swappable hard drives
installed in 3.5 inch hard-drive carriers.
• Up to sixteen 2.5 inch hot-swappable hard drives.
LCD Panel Features
NOTE: The LCD panel is supported only on systems with hot-swappable hard drives.
The system's LCD panel provides system information and status and error messages to indicate when the system is
operating correctly or when the system needs attention. See System Error Messages for information about specific
error codes.
• The LCD backlight lights blue during normal operating conditions and lights amber to indicate an error condition.
• The LCD backlight is off when the system is in standby mode and can be turned on by pressing either the Select,
Left, or Right indicator button on the LCD panel.
15
• The LCD backlight remains off if LCD messaging is turned off through the iDRAC utility, the LCD panel, or other tools.
Figure 5. LCD Panel Features
Item Button Description
1 Left Moves the cursor back in one-step increments.
2 Select Selects the menu item highlighted by the cursor.
3 Right Moves the cursor forward in one-step increments.
During message scrolling:
• Press once to increase scrolling speed.
• Press again to stop.
• Press again to return to default scrolling speed.
• Press again to repeat the cycle.
Home Screen
The Home screen displays user-configurable information about the system. This screen is displayed during normal
system operation when there are no status messages or errors. When the system is in standby mode, the LCD backlight
turns off after five minutes of inactivity if there are no error messages. Press one of the three navigation buttons (Select,
Left, or Right) to view the Home screen.
To navigate to the Home screen from another menu, continue to select the up arrow until the Home icon is
displayed, and then select the Home icon.
From the Home screen, press the Select button to enter the main menu.
Setup Menu
NOTE: When you select an option in the Setup menu, you must confirm the option before proceeding to the next
action.
Option Description
iDRAC Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available
fields are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view
domain addresses. Two separate DNS entries are available.
Set error Select SEL to display LCD error messages in a format that matches the IPMI description in the
SEL. This is useful when trying to match an LCD message with an SEL entry.
Select Simple to display LCD error messages in a simplified user-friendly description. See
System Error Messages for a list of messages in this format.
16
Option Description
Set home Select the default information to be displayed on the LCD Home screen. See View Menu to see
the options and option items that can be set as the default on the Home screen.
View Menu
NOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next
action.
Option Description
iDRAC IP Displays the IPv4 or IPv6 addresses for the iDRAC7. Addresses include DNS (Primary and
Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).
MAC Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Name Displays the name of the Host, Model, or User String for the system
Number Displays the Asset tag or the Service tag for the system.
Power Displays the power output of the system in BTU/hr or Watts. The display format can be
configured in the Set home submenu of the Setup menu.
Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format can be
configured in the Set home submenu of the Setup menu.
Diagnostic Indicators
NOTE: Systems with cabled hard drives support diagnostic indicators.
The diagnostic indicators on the system front panel display error status during system startup.
NOTE: No diagnostic indicators are lit when the system is switched off. To start the system, plug it into a working
power source and press the power button.
The following section describes system conditions and possible corrective actions associated with these indicators:
Health Indicator
Condition Corrective Action
If the system is on,
and in good health,
the indicator lights
solid blue.
None required.
The indicator blinks
amber if the system
is on or in standby,
and any error exists
(for example, a failed
fan or hard drive)
See the System Event Log or system messages for the specific issue.
Invalid memory configurations can cause the system to halt at
startup without any video output. See Getting Help.
17
Hard-drive Indicator
Condition Corrective Action
The indicator lights
green to indicate
hard-drive activity.
None required.
Electrical Indicator
Condition Corrective Action
The indicator blinks
amber if the system
experiences an
electrical error (for
example, voltage out
of range, or a failed
power supply or
voltage regulator).
See the System Event Log or system messages for the specific issue.
If it is due to a problem with the power supply, check the LED on the
power supply. Re-seat the power supply by removing and reinstalling
it. If the problem persists, see Getting Help.
Temperature Indicator
Condition Corrective Action
The indicator blinks
amber if the system
experiences a
thermal error (for
example, a
temperature out of
range or fan failure).
Ensure that none of the following conditions exist:
• A cooling fan is removed or has failed.
• System cover, cooling shroud, EMI filler panel, memory-module
blank, or back-filler bracket is removed.
• Ambient temperature is too high.
• External airflow is obstructed.
See Getting Help.
Memory Indicator
Condition Corrective Action
The indicator blinks
amber if a memory
error occurs.
See the system event log or system messages for the location of the
failed memory. Reinstall the memory device. If the problem persists,
see Getting Help.
18
PCIe Indicator
Condition Corrective Action
The indicator blinks
amber if a PCIe card
experiences an
error.
Restart the system. Update any required drivers for the PCIe card.
Re-install the card. If the problem persists, see Getting Help.
Hard-Drive Indicator Patterns
Figure 6. Hard-Drive Indicators
1. hard-drive activity indicator (green)
2. hard-drive status indicator (green and amber)
NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side)
does not function and remains off.
Drive-Status
Indicator Pattern
(RAID Only)
Condition
Blinks green two
times per second
Identifying drive or preparing for removal
Off Drive ready for insertion or removal
NOTE: The drive status indicator remains off until all hard drives are initialized after the
system is turned on. Drives are not ready for insertion or removal during this time.
Blinks green, amber,
and off
Predicted drive failure
Blinks amber four
times per second
Drive failed
Blinks green slowly Drive rebuilding
Steady green Drive online
19
Drive-Status
Indicator Pattern
(RAID Only)
Condition
Blinks green three
seconds, amber three
seconds, and off six
seconds
Rebuild aborted
Back-Panel Features And Indicators
Figure 7. Back-Panel Features and Indicators
20
Item Indicator, Button, or
Connector Icon Description
1 Power supplies (PSU1 and
PSU2) Redundant power
supply
Up to two 495 W or 750 W AC
redundant power supplies.
Non-redundant
power supply
One 350 W non-redundant AC
power supply.
NOTE: Non-redundant power
supply is supported in
systems with cabled hard
drives and systems with an
x8 backplane.
2 PCIe expansion card slots
(5)
Allow you to connect up to five full-height PCIe expansion
cards.
3 vFlash media card slot Allows you to insert a vFlash media card.
4 iDRAC7 Enterprise port Dedicated management port.
NOTE: The port is available for use only if the iDRAC7
Enterprise license is installed on your system.
5 System identification button The identification buttons on the front and back panels
can be used to locate a particular system within a rack.
When one of these buttons is pressed, the LCD panel on
the front and the system status indicator on the back flash
until one of the buttons is pressed again.
Press to toggle the system ID on and off.
If the system stops responding during POST, press and
hold the system ID button for more than five seconds to
enter the BIOS progress mode.
To reset iDRAC (if not disabled in F2 iDRAC setup), press
and hold for more than 15 seconds.
6 System identification
connector
Allows you to connect the optional system status indicator
assembly through the optional cable management arm.
7 USB connectors (6) Allow you to connect USB devices to the system. The
ports are USB 2.0-compliant.
8 Ethernet connectors (2) Two integrated 10/100/1000 Mbps NIC connectors.
9 Video connector Allows you to connect a VGA display to the system.
10 Serial connector Allows you to connect a serial device to the system.
11 External cooling fan power
cable slot
Slot for routing the power cable of the optional external
cooling fan into the chassis.
21
NIC Indicator Codes
Figure 8. NIC Indicator
1. link indicator
2. activity indicator
Indicator Indicator Code
Link and activity
indicators are off
The NIC is not connected to the network.
Link indicator is
green
The NIC is connected to a valid network at its maximum port speed (1 Gbps or 10 Gbps).
Link indicator is
amber
The NIC is connected to a valid network at less than its maximum port speed.
Activity indicator is
blinking green
Network data is being sent or received.
Power Indicator Codes For Redundant Power Supply
Each redundant AC power supply has an illuminated translucent handle to show whether power is present or whether a
power fault has occurred.
Figure 9. Redundant AC Power Supply Status Indicator
1. AC power supply status handle
22
Power Indicator
Pattern
Condition
Not lit Power is not connected.
Green A valid power source is connected to the power supply and the power supply is operational.
Flashing amber Indicates a problem with the power supply.
CAUTION: When correcting a power supply mismatch, replace only the power supply with
the flashing indicator. Swapping the opposite power supply to make a matched pair can
result in an error condition and unexpected system shutdown. To change from a High
Output configuration to a Low Output configuration or vice versa, you must power down
the system.
CAUTION: AC power supplies support both 220 V and 110 V input voltages. When two
identical power supplies receive different input voltages, they can output different
wattages, and trigger a mismatch.
CAUTION: If two power supplies are used, they must be of the same type and have the
same maximum output power.
Flashing green When hot-adding a power supply, this indicates that the power supply is mismatched with the
other power supply (in terms of efficiency, feature set, health status, and supported voltage).
Replace the power supply that has the flashing indicator with a power supply that matches the
capacity of the other installed power supply.
Power Indicator Codes For Non-Redundant Power Supply
Press the self-diagnostic button to perform a quick health check on the non-redundant power supply of the system.
Diagnostic Indicator
Pattern
Condition
Not lit Power is not connected or power supply is faulty.
Green A valid power source is connected to the power supply and the power supply is operational.
23
Figure 10. Non-Redundant AC Power Supply Status Indicator and Self-Diagnostic Button
1. self-diagnostic button
2. AC power supply status indicator
Other Information You May Need
WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be
included within this document or as a separate document.
• The
Getting Started Guide
provides an overview of setting up your system, and technical specifications. This
document is available online at www.dell.com/support/manuals.
• The rack documentation included with your rack solution describes how to install your system into a rack, if
required.
• Any media that ships with your system that provides documentation and tools for configuring and managing your
system, including those pertaining to the operating system, system management software, system updates, and
system components that you purchased with your system.
• For the full name of an abbreviation or acronym used in this document, see the Glossary at www.dell.com/support/
manuals.
NOTE: Always check for updates on www.dell.com/support/manuals and read the updates first because they often
supersede information in other documents.
24
2
Using The System Setup And Boot Manager
System Setup enables you to manage your system hardware and specify BIOS-level options.
The following keystrokes provide access to system features during startup:
Keystroke Description
<F2> Enters the System Setup.
<F10> Enters System Services, which opens the Dell Lifecycle
Controller 2 (LC2). The Dell LC2 supports systems
management features such as operating system
deployment, hardware diagnostics, firmware updates, and
platform configuration, using a graphical user interface.
The exact LC2 feature set is determined by the iDRAC
license purchased. For more information, see the Dell LC2
documentation.
<F11> Enters the BIOS Boot Manager or the Unified Extensible
Firmware Interface (UEFI) Boot Manager, depending on
the system's boot configuration
.
<F12> Starts Preboot Execution Environment (PXE) boot.
From the System Setup, you can:
• Change the NVRAM settings after you add or remove hardware
• View the system hardware configuration
• Enable or disable integrated devices
• Set performance and power management thresholds
• Manage system security
You can access the System Setup using the:
• Standard graphical browser, which is enabled by default
• Text browser, which is enabled using Console Redirection
To enable Console Redirection, in System Setup, select System BIOS → Serial Communication screen → Serial
Communication, select On with Console Redirection.
NOTE: By default, help text for the selected field is displayed in the graphical browser. To view the help text in the
text browser, press <F1>.
Choosing The System Boot Mode
System Setup enables you to specify the boot mode for installing your operating system:
• BIOS boot mode (the default) is the standard BIOS-level boot interface.
25
• UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface (UEFI)
specifications that overlays the system BIOS.
You must select the boot mode in the Boot Mode field of the Boot Settings screen of System Setup. Once you specify the
boot mode, the system boots in the specified boot mode and you then proceed to install your operating system from that
mode. Thereafter, you must boot the system in the same boot mode (BIOS or UEFI) to access the installed operating
system. Trying to boot the operating system from the other boot mode will cause the system to halt at startup.
NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit
operating systems do not support UEFI and can only be installed from the BIOS boot mode.
NOTE: For the latest information on supported operating systems, go to dell.com/ossupport.
Entering System Setup
1. Turn on or restart your system.
2. Press <F2> immediately after you see the following message:
<F2> = System Setup
If your operating system begins to load before you press <F2>, allow the system to finish booting, and then restart
your system and try again.
Responding To Error Messages
If an error message is displayed while the system is booting, make a note of the message. For more information, see
System Error Messages.
NOTE: After installing a memory upgrade, it is normal for your system to display a message the first time you start
your system.
Using The System Setup Navigation Keys
Keys Action
Up arrow Moves to the previous field.
Down arrow Moves to the next field.
<Enter> Allows you to type in a value in the selected field (if applicable) or follow the link in the field.
Spacebar Expands or collapses a drop-down menu, if applicable.
<Tab> Moves to the next focus area.
NOTE: For the standard graphics browser only.
<Esc> Moves to the previous page till you view the main screen. Pressing <Esc> in the main screen
displays a message that prompts you to save any unsaved changes and restarts the system.
<F1> Displays the System Setup help file.
NOTE: For most of the options, any changes that you make are recorded but do not take
effect until you restart the system.
26
System Setup Options
System Setup Main Screen
NOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings.
Menu Item Description
System BIOS This option is used to view and configure BIOS settings.
iDRAC Settings This option is used to view and configure iDRAC settings.
Device Settings This option is used to view and configure device settings.
System BIOS Screen
NOTE: The options for System Setup change based on the system configuration.
NOTE: System Setup defaults are listed under their respective options in the following sections, where applicable.
Menu Item Description
System Information Displays information about the system such as the system model name, BIOS version, Service
Tag, and so on.
Memory Settings Displays information and options related to installed memory.
Processor Settings Displays information and options related to the processor such as speed, cache size, and so
on.
SATA Settings Displays options to enable or disable the integrated SATA controller and ports.
Boot Settings Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS
boot settings.
Integrated Devices Displays options to enable or disable integrated device controllers and ports, and to specify
related features and options.
Serial Communication Displays options to enable or disable the serial ports and specify related features and options.
System Profile
Settings
Displays options to change the processor power management settings, memory frequency,
and so on.
System Security Displays options to configure the system security settings like, system password, setup
password, TPM security, and so on. It also enables or disables support for local BIOS update,
the power and NMI buttons on the system.
Miscellaneous
Settings
Displays options to change the system date, time, and so on.
System Information Screen
Menu Item Description
System Model Name Displays the system model name.
27
Menu Item Description
System BIOS Version Displays the BIOS version installed on the system.
System Service Tag Displays the system Service Tag.
System Manufacturer Displays the name of system manufacturer.
System Manufacturer
Contact Information
Displays the contact information of the system manufacturer.
Memory Settings Screen
Menu Item Description
System Memory Size Displays the amount of memory installed in the system.
System Memory Type Displays the type of memory installed in the system.
System Memory
Speed
Displays the system memory speed.
System Memory
Voltage
Displays the system memory voltage.
Video Memory Displays the amount of video memory.
System Memory
Testing
Specifies whether system memory tests are run during system boot. Options are Enabled and
Disabled. By default, the System Memory Testing option is set to Disabled.
Memory Operating
Mode
Specifies the memory operating mode. The options available depending on the memory
configuration of your system are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare
Mode, Spare with Advanced ECC Mode, and Dell Fault Resilient Mode. By default, the Memory
Operating Mode option is set to Optimizer Mode.
NOTE: The Memory Operating Mode can have different defaults and available options
based on the memory configuration.
NOTE: The Dell Fault Resilient Mode establishes an area of memory that is fault resilient.
This mode can be used by an operating system that supports the feature to load critical
applications or enables the operating system kernel to maximize system availability.
Node Interleaving If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is
installed. If Disabled, the system supports Non-Uniform Memory architecture (NUMA)
(asymmetric) memory configurations. By default, Node Interleaving option is set to Disabled.
Processor Settings Screen
Menu Item Description
Logical Processor Allows you to enable or disable logical processors and display the number of logical
processors. If the Logical Processor option is set to Enabled, the BIOS displays all the logical
processors. If this option is set to Disabled, the BIOS only displays one logical processor per
core. By default, the Logical Processor option is set to Enabled.
QPI Speed Allows you to set the QuickPath Interconnect data rate settings. By default, the QPI Speed
option is set to Maximum data rate.
28
Menu Item Description
NOTE: The QPI speed option displays only when both the processors are installed.
Alternate RTID
(Requestor
Transaction ID)
Setting
Allows you to allocate more RTIDs to the remote socket increasing cache performance
between the sockets or work in normal mode for NUMA. By default, the Alternate RTID
(Requestor Transaction ID) Setting is set to Disabled.
Virtualization
Technology
Allows you to enable or disable the additional hardware capabilities provided for virtualization.
By default, the Virtualization Technology option is set to Enabled.
Adjacent Cache Line
Prefetch
Allows you to optimize the system for applications that require high utilization of sequential
memory access. By default, the Adjacent Cache Line Prefetch option is set to Enabled. You can
disable this option for applications that require high utilization of random memory access.
Hardware Prefetcher Allows you to enable or disable hardware prefetcher. By default, the Hardware Prefetcher
option is set to Enabled.
DCU Streamer
Prefetcher
Allows you to enable or disable Data Cache Unit streamer prefetcher. By default, the DCU
Streamer Prefetcher option is set to Enabled.
DCU IP Prefetcher Allows you to enable or disable Data Cache Unit IP prefetcher. By default, the DCU IP
Prefetcher option is set to Enabled.
Execute Disable Allows you enable or disable execute disable memory protection technology. By default, the
Execute Disable option is set to Enabled.
Logical Processor
Idling
Allows you to enable or disable the OS capability to put logical processors in the idling state in
order to reduce power consumption. By default, the option is set to Disabled.
Number of Cores per
Processor
Allows you to control the number of enabled cores in each processor. By default, the Number
of Cores per Processor option is set to All.
Processor 64-bit
Support
Specifies if the processor(s) support 64-bit extensions.
Processor Core
Speed
Displays the maximum core frequency of the processor.
Processor Bus Speed Displays the bus speed of the processors.
NOTE: The processor bus speed option displays only when both the processors are
installed.
Processor 1 NOTE: The following settings are displayed for each processor installed in the system.
Family-Model-
Stepping
Displays the family, model and stepping of the processor as defined by Intel.
Brand Displays the brand name reported by the processor.
Level 2 Cache Displays the total L2 cache.
Level 3 Cache Displays the total L3 cache.
Number of Cores Displays the number of cores per processor.
29
SATA Settings Screen
Menu Item Description
Embedded SATA Allows the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By default, the
Embedded SATA option is set to AHCI.
Port A Auto enables BIOS support for the device attached to SATA port A. Off disables BIOS support
for the device. By default, Port A is set to Auto.
Port B Auto enables BIOS support for the device attached to SATA port B. Off disables BIOS support
for the device. By default, Port B is set to Auto.
Port C Auto enables BIOS support for the device attached to SATA port C. Off disables BIOS support
for the device. By default, Port C is set to Auto.
Port D Auto enables BIOS support for the device attached to SATA port D. Off disables BIOS support
for the device. By default, Port D is set to Auto.
Port E Auto enables BIOS support for the device attached to SATA port E. Off disables BIOS support
for the device. By default, Port E is set to Auto.
Port F Auto enables BIOS support for the device attached to SATA port F. Off disables BIOS support
for the device. By default, Port F is set to Auto.
Boot Settings Screen
Menu Item Description
Boot Mode Allows you to set the boot mode of the system.
CAUTION: Switching the boot mode may prevent the system from booting if the operating
system is not installed in the same boot mode.
If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS
allows compatibility with non-UEFI operating systems. By default, the Boot Mode option is set
to BIOS.
NOTE: Setting this field to UEFI disables BIOS Boot Settings menu. Setting this field to
BIOS disables the UEFI Boot Settings menu.
Boot Sequence Retry Allows you to enable or disable the boot sequence retry feature. If this field is enabled and the
system fails to boot, the system reattempts the boot sequence after 30 seconds. By default, the
Boot Sequence Retry option is set to Disabled.
BIOS Boot Settings Allows you to enable or disable BIOS Boot options.
NOTE: This option is enabled only if the boot mode is BIOS.
UEFI Boot Settings Allows you to enable or disable UEFI Boot options. The Boot options include IPv4 PXE and IPv6
PXE. By default, the UEFI PXE boot protocol is set to IPv4.
NOTE: This option is enabled only if the boot mode is UEFI.
One-Time Boot Allows you to enable or disable a one-time boot from a selected device.
30
Integrated Devices Screen
Menu Item Description
User Accessible USB
Ports
Allows you enable or disable the user accessible USB ports. Selecting Only Back Ports On
disables the front USB ports and selecting All Ports Off disables both front and back USB ports.
By default, the User Accessible USB Ports option is set to All Ports On.
Internal USB Port Allows you to enable or disable the internal USB port. By default, the Internal USB Port option
is set to On.
Internal SD Card Port Enables or disables the system’s internal SD card port. By default, Internal SD Card Port option
is set to On.
NOTE: This option is displayed only if IDSDM is installed on the system board.
Internal SD Card
Redundancy
If set to Mirror mode, data is written on both SD cards. If any one of the SD card fails, data is
written to the active SD card. Data from this card is copied to the replacement SD card at the
next boot. By default, Internal SD Card Redundancy option is set to Mirror.
NOTE: This option is displayed only if IDSDM is installed on the system board.
Embedded NIC1 &
NIC2
Allows you to enable or disable Embedded NIC1 & NIC2. By default, the Embedded NIC1 &
NIC2 option is set to Enabled.
OS Watchdog Timer Allows you to enable or disable the OS watchdog timer. When this field is enabled, the
operating system initializes the timer and the OS watchdog timer helps in recovering the
operating system. By default, the OS Watchdog Timer option is set to Disabled.
Embedded Video
Controller
Allows you to enable or disable the Embedded Video Controller. By default, the embedded
video controller is Enabled.
SR-IOV Global Enable Allows you to enable or disable the BIOS configuration of Single Root I/O Virtualization (SR-
IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.
Memory Mapped I/O
above 4GB
Allows you to enable support for PCIe devices that require large amounts of memory. By
default, the option is set to Enabled.
Slot Disablement Allows you to enable or disable available PCIe slots on your system. The Slot Disablement
feature controls the configuration of PCIe cards installed in the specified slot.
CAUTION: Slot disablement must be used only when the installed peripheral card is
preventing booting into the Operating System or causing delays in system startup. If the
slot is disabled, both the Option ROM and UEFI driver are disabled.
Serial Communications Screen
Menu Item Description
Serial Communication Allows you to select serial communication devices (Serial Device 1 and Serial Device 2) in the
BIOS. BIOS console redirection can also be enabled and the port address used can be
specified. By default, Serial Communication option is set to On without Console Redirection.
31
Menu Item Description
Serial Port Address Allows you to set the port address for serial devices. By default, the Serial Port Address option
is set to Serial Device 1=COM2, Serial Device 2=COM1.
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console
redirection by SOL, configure the same port address for console redirection and the serial
device.
External Serial
Connector
Allows you to associate the external serial connector to serial device 1, serial device 2, or
remote access device. By default, the External Serial Connector option is set to Serial Device1.
NOTE: Only Serial Device 2 can be used for SOL. To use console redirection by SOL,
configure the same port address for console redirection and the serial device.
Failsafe Baud Rate Displays the failsafe baud rate for console redirection. The BIOS attempts to determine the
baud rate automatically. This failsafe baud rate is used only if the attempt fails and the value
must not be changed. By default, the Failsafe Baud Rate option is set to 11520.
Remote Terminal
Type
Allows you to set the remote console terminal type. By default, the Remote Terminal Type
option is set to VT 100/VT 220.
Redirection After
Boot
Allows you to enable or disable to the BIOS console redirection when the operating system is
loaded. By default, the Redirection After Boot option is set to Enabled.
System Profile Settings Screen
Menu Item Description
System Profile Allows you to set the system profile. If you set the System Profile option to a mode other than
Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the
options if the mode is set to Custom. By default, the System Profile option is set to Performance
Per Watt Optimized (DAPC). DAPC is Dell Active Power Controller.
NOTE: The following parameters are available only when the System Profile is set to
Custom.
CPU Power
Management
Allows you to set the CPU power management. By default, the CPU Power Management option
is set to System DBPM (DAPC). DBPM is Demand-Based Power Management.
Memory Frequency Allows you to set the memory frequency. By default, the Memory Frequency option is set to
Maximum Performance.
Turbo Boost Allows you to enable or disable the processor to operate in turbo boost mode. By default, the
Turbo Boost option is set to Enabled.
C1E Allows you to enable or disable the processor to switch to a minimum performance state when
it is idle. By default, the C1E option is set to Enabled.
C States Allows you to enable or disable the processor to operate in all available power states. By
default, the C States option is set to Enabled.
Monitor/Mwait Allows you to enable Monitor/Mwait instructions in the processor. By default, the Monitor/
Mwait option is set to Enabled for all system profiles, except Custom.
NOTE: This option can be disabled only if the C States option in Custom mode is disabled.
32
Menu Item Description
NOTE: When C States is enabled in Custom mode, changing the Monitor/Mwait setting
does not impact system power/performance.
Memory Patrol Scrub Allows you to set the memory patrol scrub frequency. By default, the Memory Patrol Scrub
option is set to Standard.
Memory Refresh Rate Allows you to set the memory refresh rate. By default, the Memory Refresh Rate option is set to
1x.
Memory Operating
Voltage
Allows you to set the DIMM voltage selection. When set to Auto, the system automatically sets
the system voltage to the optimal setting based on the DIMM capacity and the number of
DIMMs installed. By default, the Memory Operating Voltage option is set to Auto.
Collaborative CPU
Performance Control
When set to enabled, the CPU power management is controlled by the OS DBPM and the
System DBPM (DAPC). By default, the option is set to Disabled
System Security Screen
Menu Item Description
Intel AES-NI The Intel AES-NI option improves the speed of applications by performing encryption and
decryption using the Advanced Encryption Standard Instruction Set and is set to Enabled by
default.
System Password Allows you to set the system password. This option is set to Enabled by default and is read-only
if the password jumper is not installed in the system.
Setup Password Allows you to set the setup password. This option is read-only if the password jumper is not
installed in the system.
Password Status Allows you to lock the system password. By default, the Password Status option is set to
Unlocked.
TPM Security Allows you to control the reporting mode of the Trusted Platform Module (TPM). By default, the
TPM Security option is set to Off. You can only modify the TPM Status, TPM Activation , and
Intel TXT fields if the TPM Status field is set to either On with Pre-boot Measurements or On
without Pre-boot Measurements.
TPM Activation Allows you to change the operational state of the TPM. By default, the TPM Activation option is
set to No Change.
TPM Status Displays the TPM status.
TPM Clear CAUTION: Clearing the TPM results in loss of all keys in the TPM. The loss of TPM keys
may affect booting to the operating system.
Allows you to clear all the contents of the TPM. By default, the TPM Clear option is set to No.
Intel TXT Allows you enable or disable Intel Trusted Execution Technology. To enable Intel TXT,
Virtualization Technology must be enabled and TPM Security must be Enabled with Pre-boot
measurements. By default, the Intel TXT option is set to Off.
Power Button Allows you to enable or disable the power button on the front of the system. By default, the
Power Button option is set to Enabled.
33
Menu Item Description
NMI Button Allows you to enable or disable the NMI button on the front of the system. By default, the NMI
Button option is set to Disabled.
AC Power Recovery Allows you to set how the system reacts after AC power is restored to the system. By default,
the AC Power Recovery option is set to Last.
AC Power Recovery
Delay
Allows you to set how the system supports staggering of power up after AC power is restored
to the system. By default, the AC Power Recovery Delay option is set to Immediate.
User Defined Delay
(60s to 240s)
Allows you to set the User Defined Delay when the User Defined option for AC Power Recovery
Delay is selected.
Miscellaneous Settings
Menu Item Description
System Time Allows you to set the time on the system.
System Date Allows you to set the date on the system.
Asset Tag Displays the asset tag and allows you to modify it for security and tracking purposes.
Keyboard NumLock Allows you to set whether the system boots with the NumLock enabled or disabled. By default
the Keyboard NumLock is set to On.
NOTE: This field does not apply to 84-key keyboards.
Report Keyboard
Errors
Allows you to set whether keyboard-related error messages are reported during system boot.
By default, the Report Keyboard Errors field is set to Report.
F1/F2 Prompt on Error Allows you to enable or disable the F1/F2 prompt on error. By default, F1/F2 Prompt on Error is
set to Enabled.
System And Setup Password Features
You can create a system password and a setup password to secure your system. To enable creation of the system and
setup password, the password jumper must be set to enabled. For more information on the password jumper settings,
see System Board Jumper Settings.
System password This is the password that you must enter before you can boot your system.
Setup password This is the password that you must enter to access and make changes to the BIOS or UEFI
settings of your system.
CAUTION: The password features provide a basic level of security for the data on your system.
CAUTION: Anyone can access the data stored on your system if the system is running and unattended.
NOTE: Your system is shipped with the system and setup password feature disabled.
34
Assigning A System And/Or Setup Password
NOTE: The password jumper enables or disables the System Password and Setup Password features. For more
information on the password jumper settings, see System Board Jumper Settings.
You can assign a new System Password and/or Setup Password or change an existing System Password and/or Setup
Password only when the password jumper setting is enabled and Password Status is Unlocked. If the Password Status
is Locked, you cannot change the System Password and/or Setup Password.
If the password jumper setting is disabled, the existing System Password and Setup Password is deleted and you need
not provide the system password to boot the system.
To assign a system and/or setup password:
1. To enter System Setup, press <F2> immediately after a power-on or reboot.
2. In the System Setup Main Menu, select System BIOS and press <Enter>.
The System BIOS screen is displayed.
3. In the System BIOS screen, select System Security and press <Enter>.
The System Security screen is displayed.
4. In the System Security screen, verify that Password Status is Unlocked.
5. Select System Password , enter your system password, and press <Enter> or <Tab>.
Use the following guidelines to assign the system password:
– A password can have up to 32 characters.
– The password can contain the numbers 0 through 9.
– Only lower case letters are valid, upper case letters are not allowed.
– Only the following special characters are allowed: space, (”), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`).
A message prompts you to re-enter the system password.
6. Re-enter the system password that you entered earlier and click OK.
7. Select Setup Password, enter your system password and press <Enter> or <Tab>.
A message prompts you to re-enter the setup password.
8. Re-enter the setup password that you entered earlier and click OK.
9. Press <Esc> to return to the System BIOS screen. Press <Esc> again, and a message prompts you to save the
changes.
NOTE: Password protection does not take effect until the system reboots.
Deleting Or Changing An Existing System And/Or Setup Password
Ensure that the Password jumper is set to enabled and the Password Status is Unlocked before attempting to delete or
change the existing System and/or Setup password. You cannot delete or change an existing System or Setup password
if the Password Status is Locked.
To delete or change the existing System and/or Setup password:
1. To enter System Setup, press <F2> immediately after a power-on or restart.
2. In the System Setup Main Menu, select System BIOS and press <Enter>.
The System BIOS screen is displayed.
3. In the System BIOS Screen, select System Security and press <Enter>.
The System Security screen is displayed.
35
4. In the System Security screen, verify that Password Status is Unlocked.
5. Select System Password, alter or delete the existing system password and press <Enter> or <Tab>.
6. Select Setup Password, alter or delete the existing setup password and press <Enter> or <Tab>.
NOTE: If you change the System and/or Setup password a message prompts you to re-enter the new
password. If you delete the System and/or Setup password, a message prompts you to confirm the deletion.
7. Press <Esc> to return to the System BIOS screen. Press <Esc> again, and a message prompts you to save the
changes.
NOTE: You can disable password security while logging on to the system. To disable the password security, turn on
or reboot your system, type your password and press <Ctrl><Enter>.
Using Your System Password To Secure Your System
NOTE: If you have assigned a setup password, the system accepts your setup password as an alternate system
password.
1. Turn on or reboot your system.
2. Type your password and press <Enter>.
When Password Status is Locked, type the password and press <Enter> when prompted at reboot.
If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password.
You have three attempts to enter the correct password. After the third unsuccessful attempt, the system displays an
error message that the system has halted and must be powered down.
Even after you shut down and restart the system, the error message is displayed until the correct password is entered.
NOTE: You can use the Password Status option in conjunction with the System Password and Setup Password
options to protect your system from unauthorized changes.
Operating With A Setup Password Enabled
If Setup Password is Enabled, enter the correct setup password before modifying most of the System Setup options.
If you do not enter the correct password in three attempts, the system displays the message
Invalid Password! Number of unsuccessful password attempts: <x> System Halted!
Must power down.
Even after you shut down and restart the system, the error message is displayed until the correct password is entered.
The following options are exceptions:
• If System Password is not Enabled and is not locked through the Password Status option, you can assign a system
password.
• You cannot disable or change an existing system password.
NOTE: You can use the Password Status option in conjunction with the Setup Password option to protect the
system password from unauthorized changes.
Entering The UEFI Boot Manager
NOTE: Operating systems must be 64-bit UEFI-compatible (for example, Microsoft Windows Server 2008 x64
version) to be installed from the UEFI boot mode. DOS and 32-bit operating systems can only be installed from the
BIOS boot mode.
The Boot Manager enables you to:
36
• Add, delete, and arrange boot options.
• Access System Setup and BIOS-level boot options without restarting.
To enter the Boot Manager:
1. Turn on or restart your system.
2. Press <F11> after you see the following message:
<F11> = UEFI Boot Manager
If your operating system begins to load before you press <F11>, allow the system to finish booting, and then restart
your system and try again.
Using The Boot Manager Navigation Keys
Key Description
Up arrow Moves to the previous field.
Down arrow Moves to the next field.
<Enter> Allows you to type in a value in the selected field (if applicable) or follow the link in the field.
Spacebar Expands or collapses a drop-down list, if applicable.
<Tab> Moves to the next focus area.
NOTE: For the standard graphics browser only.
<Esc> Moves to the previous page till you view the main screen. Pressing <Esc> in the main screen
exits the Boot Manager and proceeds with system boot.
NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the
system.
Boot Manager Screen
Menu Item Description
Continue Normal
Boot
The system attempts to boot to devices starting with the first item in the boot order. If the boot
attempt fails, the system continues with the next item in the boot order until the boot is
successful or no more boot options are found.
BIOS Boot Menu Displays the list of available BIOS boot options (marked with asterisks). Select the boot option
you wish to use and press <Enter>.
UEFI Boot Menu Displays the list of available UEFI boot options (marked with asterisks). Select the boot option
you wish to use and press <Enter>. The UEFI Boot Menu enables you to Add Boot Option,
Delete Boot Option, or Boot From File.
Driver Health Menu Displays a list of the drivers installed on the system and their health status.
Launch System Setup Enables you to access the System Setup.
System Utilities Enables you to access the BIOS Update File Explorer, run the Dell Diagnostics program, and
reboot the system.
37
UEFI Boot Menu
Menu Item Description
Select UEFI Boot
Option
Displays the list of available UEFI boot options (marked with asterisks), select the boot option
you wish to use and press <Enter>.
Add Boot Option Adds a new boot option.
Delete Boot Option Deletes an existing boot option.
Boot From File Sets a one-time boot option not included in the boot option list.
Embedded System Management
The Dell Lifecycle Controller provides advanced embedded systems management throughout the server’s lifecycle. The
Lifecycle Controller can be started during the boot sequence and can function independently of the operating system.
NOTE: Certain platform configurations may not support the full set of features provided by the Lifecycle Controller.
For more information about setting up the Lifecycle Controller, configuring hardware and firmware, and deploying the
operating system, see the Lifecycle Controller documentation at dell.com/support/manuals.
iDRAC Settings Utility
The iDRAC Settings utility is an interface to setup and configure the iDRAC parameters using UEFI. You can enable or
disable various iDRAC parameters using the iDRAC Settings Utility.
NOTE: Accessing some of the features on the iDRAC Settings Utility requires the iDRAC7 Enterprise License
upgrade.
For more information on using iDRAC, see the
iDRAC7 User's Guide
under Software → Systems Management → Dell
Remote Access Controllers, at dell.com/support/manuals.
Entering The iDRAC Settings Utility
1. Turn on or restart the managed system.
2. Press <F2> during Power-on Self-test (POST).
3. In the System Setup Main Menu page, click iDRAC Settings.
The iDRAC Settings screen is displayed.
Changing The Thermal Settings
The iDRAC Settings utility enables you to select and customize the thermal control settings for your system.
1. Enter the iDRAC Settings utility.
2. Under iDRAC Settings → Thermal → User Option, select between the following options:
– Default
– Maximum Exhaust Temperature
– Fan Speed Offset
38
NOTE: When the User Option is set to the default Auto setting, the user option cannot be modified.
3. Set the Maximum Air Exhaust Temperature or the Fan Speed Offset fields.
4. Click Back → Finish → Yes.
39
40
3
Installing System Components
Recommended Tools
You may need the following items to perform the procedures in this section:
• Key to the system keylock
• #1 and #2 Phillips screwdrivers
• Wrist grounding strap connected to ground
Front Bezel (Optional)
Installing The Front Bezel
1. Insert the bezel tabs into the bezel tab slots in the chassis.
2. Press the top end of the bezel into the chassis until the bezel locks into place.
3. Insert the bezel key in the keylock.
4. Keeping the keylock pressed with the bezel key, rotate the keylock to the locked position.
NOTE: The bezel key can be found taped to the inside of the bezel.
41
Figure 11. Removing and Installing the Front Bezel
1. system
2. front bezel
3. keylock
4. release latch
Removing The Front Bezel
1. Insert the bezel key in the keylock.
2. Keeping the keylock pressed with the bezel key, rotate the keylock to the unlocked position.
3. Press down on the release latch at the top of the bezel.
4. Rotate the top end of the bezel away from the system.
5. Unhook the bezel tabs from the slots on the front of the chassis.
System Feet—Tower Mode
The system feet provide stability to the system in the tower mode.
42
Removing The System Feet
NOTE: It is recommended that you remove the system feet only when you are converting the system from the tower
mode to the rack mode, or when you are replacing the system feet with the wheel assembly.
1. Rotate the system feet inward.
2. Lay the system on its side on a flat, stable surface.
3. Remove the screws securing the system feet to the base of the tower.
Figure 12. Removing and Installing the System Feet
1. base of the tower
2. system feet (4)
3. screws (4)
Installing The System Feet
1. Lay the system on its side on a flat, stable surface.
2. Secure the system feet to the base of the tower using the screws.
3. Place the system upright on a flat, stable surface and turn the system feet outward.
Wheel Assembly (Optional)—Tower Mode
The wheel assembly provides mobility to the system in the tower mode.
The wheel assembly consists of the following:
43
• Wheel assembly units (front and back)
• Two screws for the wheel assembly units
• Support unit with two screws
Removing The Wheel Assembly
1. Lay the system on a sturdy, stable surface with the wheel assembly extending off the edge of the surface.
2. Remove the two screws securing the support unit to the base of the chassis and pull out the support unit.
3. Remove the screw securing the front wheel assembly unit to the base of the chassis.
4. Offset the front wheel assembly unit slightly to the back of the system to release the retention hooks, and pull out
the front wheel assembly unit.
5. Remove the screw securing the back wheel assembly unit to the base of the chassis.
6. Offset the back wheel assembly unit slightly to the front of the system to release the retention hooks, and pull out
the back wheel assembly unit.
7. If you are not replacing the wheel assembly, install the system feet.
8. Place the system on a sturdy, stable surface and if applicable, rotate the system feet outward.
Figure 13. Removing and Installing the Wheel Assembly
1. support unit
2. screws for support unit (2)
3. slots on base of the tower (4)
4. wheel assembly unit (2)
5. screws for wheel assembly (2)
44
Installing The Wheel Assembly
1. If applicable, rotate the system feet inward.
2. Lay the system on its side on a sturdy, stable surface with the base of the system extending off the edge of the
surface.
3. If applicable, remove the system feet.
4. Align the two retention hooks on the back wheel assembly unit with the two slots on the base of the chassis, and
insert the hooks into the slots.
5. Offset the back wheel assembly slightly to the back of the system and secure the unit in place using a single screw.
6. Align the two retention hooks on the front wheel assembly with the two slots on the base of the chassis, and insert
the hooks into the slots.
7. Offset the front wheel assembly slightly to the front and secure the unit in place using a screw.
8. Using two screws, install the support unit on the base of the chassis.
9. Place the system upright on a sturdy, stable surface.
Opening And Closing The System
WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the
system by yourself.
WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric
shock.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: Do not operate the system without the cover for a duration exceeding five minutes.
Opening The System
NOTE: It is recommended that you always use a static mat and static strap while working on components in the
interior of the system.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy surface with
the wheel assembly extending off the edge of the surface.
3. Using a screwdriver, rotate the latch release lock on the system cover counter clockwise to the unlocked position.
4. Press the cover release latch and lift the cover away from the system.
45
Figure 14. Opening and Closing the System
1. cover release latch
2. latch release lock
3. system cover
4. system feet (4)
Closing The System
1. Ensure that all internal cables are connected and placed out of the way and that no tools or extra parts are left
inside the system.
2. Place the bottom edge of the system cover into the corresponding slots of the system chassis.
3. Lower the system cover onto the chassis.
4. Press the latch end of the system cover into the chassis until the latch locks into place.
5. Turn the latch release lock clockwise to the locked position.
6. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Inside The System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
46
NOTE: Components that are hot-swappable are marked orange and touch-points on the components are marked
blue.
Figure 15. Inside the System—Hot-Swappable Hard Drives
1. power interposer board
2. PCIe card holder (optional)
3. cooling shroud
4. internal cooling fan
5. external cooling fan (optional)
6. system feet (4)
7. expansion card slots (5)
8. processor heat sink
9. hard-drive backplane
47
Figure 16. Inside the System—Cabled Hard Drives
1. cabled power supply
2. PCIe card holder (optional)
3. cooling shroud
4. internal cooling fan
5. system feet (4)
6. expansion card slots (5)
7. processor heat sink
8. internal hard-drive bay
Optical Drives And Tape Drives (Optional)
Your system supports one of the following configurations:
• Systems with cabled hard drives support one optical drive and one tape drive.
• Systems with hot-swappable hard drives support up to two optical drives and one tape drive.
NOTE: If your system is installed with a double-width GPU card, the system supports only one 5.25 inch removal
media storage.
NOTE: An optical drive may be replaced by a Dell PowerVault RD1000 removable media device.
For systems with hot-swappable hard drives, the optical and tape drives can be configured as follows:
Slot 1 SATA optical drive or PowerVault RD1000
Slot 2 SATA optical drive or PowerVault RD1000 or blank
Slot 3 SAS tape drive or blank
48
Removing The Optical Drive Or Tape Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Disconnect the power and data cable from the back of the drive.
Note the routing of the power and data cable inside the chassis as you remove them from the system board and the
drive. You must route these cables properly when you replace them to prevent them from being pinched or
crimped.
5. To remove the drive, push the release latch towards the bottom of the system.
6. Slide the drive out of the system until it is free of the drive bay.
NOTE: If the drive is being permanently removed, install a blank in the slot.
NOTE: Filler brackets must be installed over empty optical drive or tape drive slots to maintain FCC
certification of the system. The brackets also keep dust and dirt out of the system and aid in proper cooling
and airflow inside the system.
7. Close the system.
8. If applicable, install the front bezel.
9. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
49
Figure 17. Removing and Installing the Optical Drive or Tape Drive
1. optical drive
2. tape drive
3. release latch
50
Figure 18. Cabling—Optical Drive and Tape Drive
1. connector for power cable extension
2. mini-SAS connector on PERC card
3. ODD2/TBU connector on system board
4. ODD1/TBU connector on system board
5. power connector on x8 backplane
6. SAS tape drive data/power connector
7. optical drive2 power connector
8. optical drive2 data connector
9. optical drive1 power connector
10. optical drive1 data connector
51
Installing The Optical Drive Or Tape Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Unpack and prepare the drive for installation.
For instructions, see the documentation that accompanied the drive.
If you are installing a SAS tape drive, you must have an internal SAS expansion card installed. See Installing An
Expansion Card.
2. If installed, remove the front bezel.
3. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
4. If applicable, rotate the system feet inward and lay the system on it side on a flat and stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
5. Open the system.
6. If applicable, remove the old drive or the drive blank.
7. Align the drive with the drive bay.
8. Slide the drive into the slot until the latch snaps into place.
9. Connect the power and data cable to the back of the drive.
10. Connect the power and data cables to the backplane and the system board.
The system board connectors are ODD1/TBU and ODD2/TBU. The system can connect up to two optical drives, or
one optical drive with one SATA tape backup unit, and one SAS tape backup unit using Dell OpenManage IT
Assistant.
NOTE: For systems configured with software RAID and installed with PowerVault RD1000 , connect the
PowerVault RD1000 data cable to ODD1/TBU (SATA_E) port and the optical drive data cable to ODD2/TBU
(SATA_F) port on the system board respectively.
11. Close the system.
12. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
13. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
14. If applicable, install the front bezel.
Cooling Shroud
Removing The Cooling Shroud
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
52
CAUTION: Never operate your system with the cooling shroud removed. The system may get overheated quickly,
resulting in shutdown of the system and loss of data.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Lift the cooling shroud away from the system.
Figure 19. Removing and Installing the Cooling Shroud
1. cooling shroud
2. chassis intrusion-switch
3. slots (2)
4. tabs on the system cooling fan (2)
5. chassis intrusion-switch connector on the
system board
Installing The Cooling Shroud
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
53
CAUTION: Do not operate the system with the cover removed for a duration exceeding 5 minutes.
NOTE: For proper seating of the cooling shroud in the system chassis, ensure that the cables inside the system are
routed along the chassis wall and secured using the cable securing clips.
1. Align the two slots on the cooling shroud with the tabs on the internal cooling fan.
2. Lower the cooling shroud into the chassis until the two slots on the cooling shroud are flush with the tabs on the
internal cooling fan.
NOTE: When the cooling shroud is properly seated, the chassis intrusion-switch on the cooling shroud
connects to the chassis intrusion-switch connector on the system board.
3. Close the system.
4. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Hard Drives—Hot-Swappable
Your system supports one of the following configurations:
• Up to eight 3.5 inch (SAS, SATA, or SSD) hot-swappable hard drives
• Up to eight 2.5 inch (SAS, SATA, or SSD) hot-swappable hard drives installed in 3.5 inch hard-drive adapters, which
are then installed in the 3.5 inch hard-drive carriers
• Up to sixteen 2.5 inch (SAS, SATA, or SSD) hot-swappable hard drives
CAUTION: Before attempting to remove or install a hot-swappable hard drive while the system is running, see the
documentation for the storage controller card to ensure that the host adapter is configured correctly to support
hot-swap hard drive removal and insertion.
CAUTION: Do not turn off or reboot your system while the hard drive is being formatted. Doing so can cause a hard
drive failure. Be aware that high-capacity hard drives can take a number of hours to format.
NOTE: All hot-swappable hard drives connect to the system board through the hard-drive backplane. Hard drives
are supplied in hot-swappable hard-drive carriers that fit in the hard-drive slots.
NOTE: Use only hot-swappable hard drives that have been tested and approved for use with the hard-drive
backplane.
Removing A Hot-Swap Hard Drive
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the
documentation supplied with your operating system.
1. From the management software, prepare the hard drive for removal. Wait until the indicators on the hard-drive
carrier signal that the hard drive can be removed safely. For more information, see the documentation for the
storage controller.
If the hard drive is online, the green activity/fault indicator flashes as the drive is turned off. When the hard-drive
indicators are off, the hard drive is ready for removal.
2. Press the release button to open the hard-drive carrier release handle.
3. Slide the hard-drive carrier out until it is free of the hard-drive slot.
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive blanks
installed.
4. Insert a hard-drive blank in the empty hard-drive slot.
54
Figure 20. Removing and Installing a Hot-Swap Hard Drive
1. release button
2. hard drive
3. hard-drive carrier handle
Installing A Hot-Swap Hard Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: Use only hard drives that have been tested and approved for use with the hard-drive backplane.
CAUTION: Combining SAS and SATA hard drives in the same RAID volume is not supported.
CAUTION: When installing a hard drive, ensure that the adjacent drives are fully installed. Inserting a hard-drive
carrier and attempting to lock its handle next to a partially installed carrier can damage the partially installed
carrier's shield spring and make it unusable.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the
documentation supplied with your operating system.
CAUTION: When a replacement hot-swappable hard drive is installed and the system is powered on, the hard drive
automatically begins to rebuild. Make absolutely sure that the replacement hard drive is blank or contains data that
you wish to have over-written. Any data on the replacement hard drive is immediately lost after the hard drive is
installed.
1. If a hard-drive blank is installed in the hard-drive slot, remove it.
2. Install a hard drive in the hard-drive carrier.
3. Press the release button on the front of the hard-drive carrier and open the hard-drive carrier handle.
4. Insert the hard-drive carrier into the hard-drive slot until the carrier connects with the backplane.
5. Close the hard-drive carrier handle to lock the hard drive in place.
55
Removing A 2.5 Inch Hard-Drive Blank
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive blanks installed.
1. If installed, remove the front bezel.
2. Press the release button and slide the hard-drive blank out until it is free of the hard-drive slot.
Figure 21. Removing and Installing a 2.5 Inch Hard-Drive Blank
1. hard-drive blank
2. release button
Installing A 2.5 Inch Hard-Drive Blank
1. If installed, remove the front bezel.
2. Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.
3. If applicable, install the front bezel.
Removing A 3.5 Inch Hard-Drive Blank
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have drive blanks installed.
1. If installed, remove the front bezel.
2. Grasp the front of the hard-drive blank, press the release button and slide the blank out until it is free of the hard-
drive slot.
56
Figure 22. Removing and Installing a 3.5 Inch Hard-Drive Blank
1. hard-drive blank
2. release button
Installing A 3.5 Inch Hard-Drive Blank
1. If installed, remove the front bezel.
2. Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.
3. If applicable, install the front bezel.
Removing A 2.5 Inch Hard Drive From A 3.5 Inch Hard-Drive Adapter
NOTE: A 2.5 inch hard drive is installed into a 3.5 inch hard-drive adapter, which is then installed in the 3.5 inch
hard-drive carrier
1. Remove the two screws from the side of the 3.5 inch hard-drive adapter.
2. Remove the hard-drive away from the hard-drive adapter.
Figure 23. Removing and Installing a 2.5 Inch Hard Drive Into a 3.5 Inch Hard-Drive Adapter
57
1. screws (2)
2. 3.5 inch hard-drive adapter
3. 2.5 inch hard drive
Installing A 2.5 Inch Hard Drive Into A 3.5 Inch Hard-Drive Adapter
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Align the screw holes on the 2.5 inch hard drive with the screw holes on the 3.5 inch hard-drive adapter.
2. Install the screws to secure the hard drive to the hard-drive adapter.
Removing A Hard Drive Or A Hard-Drive Adapter From A Hard-Drive Carrier
1. Remove the screws from the slide rails on the hard-drive carrier.
2. Lift the hard-drive adapter out of the hard-drive carrier.
Figure 24. Removing and Installing a Hot-Swap Hard Drive Into a Hard-Drive Carrier
1. hard-drive carrier
2. screws (4)
3. hard drive
4. screw holes (4)
58
Figure 25. Removing and Installing a Hard-Drive Adapter Into a 3.5 Inch Hard-Drive Carrier
1. hard-drive carrier
2. screws (5)
3. hard-drive adapter
4. 2.5 inch hard drive
Installing A Hard Drive Or A Hard-Drive Adapter Into A Hard-Drive Carrier
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Insert the hard-drive adapter into the hard-drive carrier with the connector end of the hard drive toward the back.
2. Align the screw holes on the hard drive with the back set of holes on the hard-drive carrier.
When aligned correctly, the back of the hard drive is flush with the back of the hard-drive carrier.
3. Attach the screws to secure the hard drive to the hard-drive carrier.
Hard Drives—Cabled
Your system supports up to four 3.5 inch (SAS or SATA) cabled hard drives. Cabled hard drives are installed in an
internal hard-drive bay.
59
CAUTION: Do not turn off or reboot your system while the hard drive is being formatted. Doing so can cause a hard
drive failure.
NOTE: Use only hard drives that have been tested and approved for use with your system.
Removing The Internal Hard-Drive Bay
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Disconnect the data and power cable(s) from the hard drive(s).
5. Loosen the two captive screws securing the internal hard-drive bay to the chassis.
6. Lift the internal hard-drive bay up and out of the chassis.
Figure 26. Installing and Removing the Internal Hard-Drive Bay
1. cabled hard drives (4)
2. captive screws (2)
60
3. internal hard-drive bay
Installing The Internal Hard-Drive Bay
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Align the internal hard-drive bay with the tabs on the chassis and slide the internal hard-drive bay into the chassis.
2. Secure the internal hard-drive bay to the chassis using the two captive screws.
3. Connect the data and power cable(s) to the hard drive(s).
4. Close the system.
5. Place the system upright on a flat, stable surface and if applicable, rotate the system feet outward.
6. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Removing A Cabled Hard Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the power and data cable(s) from the hard drive(s) in the internal hard-drive bay.
5. Remove the internal hard-drive bay.
6. Remove the four screws securing the hard drive to the internal hard-drive bay.
7. Remove the hard drive from the internal hard-drive bay.
8. Install the internal hard-drive bay into the chassis.
9. If applicable, connect the power and data cable(s) to the remaining hard drive(s) in the internal hard-drive bay.
61
Figure 27. Removing and Installing a Cabled Hard Drive
1. hard drive connector
2. hard drive
3. internal hard-drive bay
4. screws (4)
Installing A Cabled Hard Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Disconnect the power and data cable(s) from the hard drive(s) in the internal hard-drive bay.
5. Remove the internal hard-drive bay.
6. Insert the hard drive into the internal hard-drive bay with the hard-drive connector facing outward.
7. Secure the hard drive to the internal hard-drive bay with the four screws.
62
8. Install the internal hard-drive bay into the chassis.
9. Connect the power and data cable(s) to the hard drive(s).
10. Close the system.
11. Place the system upright on a flat, stable surface and if applicable, rotate the system feet outward.
12. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
13. Enter the System Setup and ensure that the hard drive's controller is enabled.
14. Exit the System Setup program and reboot the system.
15. Install any software required for the hard drive operation as described in the documentation for the hard drive.
Hard-Drive Backplane
Your system supports one of the following configurations:
• x8 SAS/SATA backplane for 3.5 inch hard drives
NOTE: The x8 backplane also supports up to eight 2.5 inch (SAS, SATA, or SSD) hot-swappable hard drives
installed in 3.5 inch hard-drive adapters, which are then installed in the 3.5 inch hard-drive carriers.
• x16 SAS/SATA backplane for 2.5 inch hard drives
NOTE: Your system backplane can also support SAS/SATA SSDs.
NOTE: Hard-drive backplanes are supported in systems with hot-swappable hard drives only.
Removing The Hard-Drive Backplane
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
CAUTION: To prevent damage to the drives and backplane, you must remove the hard drives from the system
before removing the backplane.
CAUTION: You must note the slot number of each hard drive and temporarily label them before removal so
that you can replace them in the same locations.
3. Remove all hard drives.
4. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
5. Open the system.
6. Disconnect the SAS, power, signal, and I2C cables from the hard-drive backplane.
NOTE: For the x8 backplane, press the SAS connector and push the connector toward the top of the system to
release the SAS cable from the backplane.
7. Pull the release pin and lift the backplane out of the system.
63
Figure 28. Removing and Installing an x8 Hard-Drive Backplane
1. x8 hard-drive backplane
2. release pin
3. hooks (11)
64
Figure 29. Connectors on an x8 Hard-Drive Backplane
1. SAS B connector
2. power connector for optical drive and tape
drive
3. backplane power connector
4. SAS A connector
5. I2C connector
65
Figure 30. Cabling—x8 Hard-Drive Backplane
1. power connector
2. SAS A connector on system board
3. I2C connector on system board
4. I2C connector on backplane
5. SAS A connector on backplane
6. backplane power connector
66
Figure 31. Removing and Installing an x16 Hard-Drive Backplane
1. x16 hard-drive backplane
2. release pin
3. hooks (7)
67
Figure 32. Connectors on an x16 Hard-Drive Backplane
1. backplane power connector
2. backplane
3. power connector for optical drive and tape
drive
4. I2C connector
5. primary SAS connectors (A and B)
6. secondary SAS connectors (A1 and B1)
68
Figure 33. Cabling—x16 Hard-Drive Backplane With Expansion Card
1. power connector on power distribution board
2. SAS B connector on PowerEdge RAID
Controller (PERC) card
3. SAS A connector on PERC card
4. I2C connector on system board
5. SAS A connector on backplane
6. SAS B connector on backplane
7. backplane power connector
8. I2C connector on backplane
Installing The Hard-Drive Backplane
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Use the hooks at the back of the hard-drive bay as guides to align the hard-drive backplane.
2. Slide down the hard-drive backplane until the release pin locks into the slot.
3. Connect the SAS, power, signal, and I2C cables to the hard-drive backplane.
4. Install the hard drives in their original locations.
69
5. Close the system.
6. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
8. If applicable, install the front bezel.
Four-Slot Hard-Drive Blank
Systems with x8 hard-drive backplanes configured for software RAID support only four hard drives. The remaining hard-
drive slots are pre-installed with the four-slot hard-drive blank, and are not available for software RAID.
Removing A Four-Slot Hard-Drive Blank
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive blanks installed.
NOTE: This is a service only procedure.
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
CAUTION: To prevent damage to the hard drives and backplane, you must remove the hard drives from the
system before removing the backplane.
CAUTION: You must note the slot number of each hard drive and temporarily label them before removal so
that you can replace them in the same location(s).
3. Remove all hard drives.
4. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy surface with
the wheel assembly extending off the edge of the surface.
5. Open the system.
6. Remove the cooling shroud.
7. Remove the x8 hard-drive backplane.
8. Using a screwdriver, push the release tabs on the four corners of the blank from inside the system, to unlock the
four-slot hard-drive blank from the chassis.
9. From the front of the system, pull the four-slot hard-drive blank at the corners until it is free of the hard-drive slot.
70
Figure 34. Installing and Removing the Four-Slot Hard-Drive Blank
1. four-slot hard-drive blank
2. release tab
3. screwdriver
Installing A Four-Slot Hard-Drive Blank
1. Locate the hard drive slots numbered from four to seven.
2. Insert the four-slot hard-drive blank into the hard-drive slot, and push it until the release tabs click into place.
3. Close the system.
4. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
5. If applicable, install the front bezel.
6. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
System Memory
Your system supports DDR3 unbuffered ECC DIMMs (ECC UDIMMs), and registered DIMMs (RDIMMs). It supports DDR3
and DDR3L voltage specifications.
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
Memory bus operating frequency can be 1600 MT/s, 1333 MT/s, 1066 MT/s, or 800 MT/s depending on:
• DIMM type (UDIMM or RDIMM)
• DIMM configuration (number of ranks)
• maximum frequency of the DIMMs
71
• number of DIMMs populated per channel
• DIMM operating voltage
• system profile selected (for example, Performance Optimized, Custom, or Dense Configuration Optimized)
• maximum supported DIMM frequency of the processor
The system contains six memory sockets organized into three channels. In each channel, the release levers of the first
socket are marked white and the second socket black.
Figure 35. Memory Socket Locations
Memory channels are organized as follows:
• channel 1: memory sockets A1 and A4
• channel 2: memory sockets A2 and A5
• channel 3: memory sockets A3 and A6
The following table shows the memory populations and operating frequencies for the supported configurations.
DIMM Type DIMMs
Populated/
Channel
Operating Frequency (in MT/s) Maximum DIMM Rank/
Channel
1.5 V 1.35 V
UDIMM ECC 1 1333, 1066, and 800 1333, 1066, and 800 Dual rank
2 1333, 1066, and 800 1333, 1066, and 800 Dual rank
72
DIMM Type DIMMs
Populated/
Channel
Operating Frequency (in MT/s) Maximum DIMM Rank/
Channel
1.5 V 1.35 V
RDIMM 1 1333, 1066, and 800
1333, 1066, and 800
1333, 1066, and 800
1066 and 800
Dual rank
Quad rank
21600, 1333, 1066, and 800
1066 and 800
1333, 1066, and 800
1066 and 800
Dual rank
Quad rank
General Memory Module Installation Guidelines
NOTE: Memory configurations that fail to observe these guidelines can prevent your system from booting, hanging
during memory configuration, or operating with reduced memory.
This system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset
architectural configuration. The following are the recommended guidelines for best performance:
• UDIMMs and RDIMMs must not be mixed.
• x4 and x8 DRAM based DIMMs can be mixed.
For more information, see Mode-Specific Guidelines.
• A maximum of two UDIMMs can be populated in a channel.
• A maximum of two single- or dual-rank RDIMMs can be populated in a channel.
• Populate all sockets with white release tabs first, and then black.
• Populate the sockets by highest rank count in the following order - first in sockets with white release levers, and
then black.
For example, if you want to mix quad-rank and dual-rank DIMMs, populate quad-rank DIMMs in the sockets with
white release tabs and dual-rank DIMMs in the sockets with black release tabs.
• Memory modules of different sizes can be mixed provided that other memory population rules are followed.
For example, 2 GB and 4 GB memory modules can be mixed.
• Depending on mode-specific guidelines, populate two or three DIMMs per processor (one DIMM per channel) at a
time to maximize performance.
For more information, see Mode-Specific Guidelines.
• If memory modules with different speeds are installed, they will operate at the speed of the slowest installed
memory module(s) or slower depending on system DIMM configuration.
Mode-Specific Guidelines
The allowable configurations depend on the memory mode selected.
NOTE: x4 and x8 DRAM based DIMMs can be mixed providing support for RAS features. However, all guidelines for
specific RAS features must be followed. x4 DRAM based DIMMs retain Single Device Data Correction (SDDC) in
either memory optimized (independent channel) or Advanced ECC modes. x8 DRAM based DIMMs require
Advanced ECC mode to gain SDDC.
The following sections provide additional slot population guidelines for each mode.
Advanced ECC (Lockstep)
Advanced ECC mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This protects against single
DRAM chip failures during normal operation.
Memory sockets A1 and A4 are disabled and you can populate DIMMs in memory sockets A2, A3, A5, and A6.
73
NOTE: Advanced ECC with Mirroring is not supported.
Memory Optimized (Independent Channel) Mode
This mode supports SDDC only for memory modules that use x4 device width and does not impose any specific slot
population requirements.
Memory Sparing
NOTE: To use memory sparing, this feature must be enabled in the System Setup.
In this mode, one rank per channel is reserved as a spare. If persistent correctable errors are detected on a rank, the
data from this rank is copied to the spare rank and the failed rank is disabled.
With memory sparing enabled, the system memory available to the operating system is reduced by one rank per
channel. For example, in a system with three 8 GB dual-rank DIMMs, the available system memory is: 1/2 (ranks/
channel) × 3 (DIMMs) × 8 GB = 12 GB, and not 3 (DIMMs) × 8 GB = 24 GB.
NOTE: Memory sparing does not offer protection against a multi-bit uncorrectable error.
NOTE: Both Advanced ECC/Lockstep and Optimizer modes support Memory Sparing.
Memory Mirroring
Memory Mirroring offers the strongest DIMM reliability mode compared to all other modes, providing improved
uncorrectable multi-bit failure protection. In a mirrored configuration, the total available system memory is one half of
the total installed physical memory. Half of the installed memory is used to mirror the active DIMMs. In the event of an
uncorrectable error, the system will switch over to the mirrored copy. This ensures SDDC and multi-bit protection.
Memory installation guidelines:
• Memory sockets A1 and A4 are disabled and you can populate DIMMs in memory sockets A2, A3, A5, and A6.
• DIMMs installed in memory sockets with white release tabs must be identical and similar rule applies for sockets
with black release tabs. For example, DIMMs installed in sockets A2 and A3 must be identical.
Sample Memory Configurations
The following table shows sample memory configurations for a single processor configuration that follow the
appropriate memory guidelines stated in this section.
NOTE: 16 GB quad-rank RDIMMs are not supported.
NOTE: 1R and 2R in the following tables indicate single- and dual-rank DIMMs respectively.
Table 1. Memory Configurations
System Capacity (in
GB) DIMM Size (in GB) Number of DIMMs DIMM Rank,
Organization, and
Frequency
DIMM Slot Population
2 2 1 1R, x8, 1333 MT/s, A1
1R, x8, 1600 MT/s
4 2 2 1R, x8, 1333 MT/s, A1, A2
1R, x8, 1600 MT/s
8 2 4 1R, x8, 1333 MT/s, A1, A2, A3, A4
74
System Capacity (in
GB) DIMM Size (in GB) Number of DIMMs DIMM Rank,
Organization, and
Frequency
DIMM Slot Population
1R, x8, 1600 MT/s
12 4 3 2R, x8, 1333 MT/s, A1, A2, A3
2R, x8, 1600 MT/s
24 8 3 2R, x4, 1333 MT/s, A1, A2, A3
2R, x4, 1600 MT/s
48 16 3 2R, x4, 1333 MT/s, A1, A2, A3
2R, x4, 1600 MT/s
96 16 6 2R, x4, 1333 MT/s, A1, A2, A3, A4, A5, A6
2R, x4, 1600 MT/s
128 32 4 4R x4, 1066 MT/s A1, A2, A3, A4
192 32 6 4R x4, 1066 MT/s A1, A2, A3, A4, A5, A6
Removing Memory Modules
WARNING: The memory modules are hot to the touch for some time after the system has been powered down.
Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges
and avoid touching the components or metallic contacts on the memory module.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is
not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. Open the system.
3. Remove the cooling shroud.
4. Locate the appropriate memory-module socket(s).
5. To release the memory-module blank from the socket, simultaneously press the ejectors on both ends of the
memory module socket.
CAUTION: Handle each memory module only on the card edges, making sure not to touch the middle of the
memory module or metallic contacts. To avoid damaging the memory module, handle only one memory
module at a time.
75
Figure 36. Ejecting The Memory Module
1. memory module
2. memory-module socket ejectors (2)
3. memory-module socket
6. If a memory module or a memory-module blank is installed in the socket, remove it.
NOTE: Retain removed memory-module blank(s) for future use.
Figure 37. Removing The Memory Module
1. memory module/memory-module blank
7. Install the cooling shroud.
8. Close the system.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing Memory Modules
WARNING: The memory modules are hot to the touch for some time after the system has been powered down.
Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges
and avoid touching the components or metallic contacts on the memory module.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
76
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is
not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2. Open the system.
3. If applicable, remove the cooling shroud.
4. Locate the memory-module sockets.
CAUTION: Handle each memory module only by the card edges, making sure not to touch the middle of the
memory module or metallic contacts. To avoid damaging the memory module, handle only one memory
module at a time.
5. If a memory module or a memory-module blank is installed in the socket, remove it.
NOTE: Retain removed memory-module blank(s) for future use.
6. Align the memory-module's edge connector with the alignment key of the memory-module socket, and insert the
memory module in the socket.
NOTE: The memory-module socket has an alignment key that allows you to install the memory module in the
socket in only one orientation.
CAUTION: To prevent damage to the memory-module socket during installation, apply pressure at both ends
of the memory module evenly. Do not apply pressure to the center of the memory module.
7. Press down on the memory module with your thumbs until the memory module snaps into place.
Figure 38. Installing The Memory Module
1. memory module
2. memory-module ejectors
3. memory-module socket alignment key
4. memory-module alignment key
NOTE: When the memory module is properly seated in the socket, the levers on the memory-module socket
align with the levers on the other identical sockets that have memory modules installed.
8. Repeat step 4 through step 7 of this procedure to install the remaining memory modules.
9. Replace the cooling shroud.
10. Close the system.
77
11. Reconnect the system to its electrical outlet and turn on the system, including any attached peripherals.
12. Press <F2> to enter the System Setup, and check the memory settings.
The system should have already changed the value to reflect the newly installed memory.
13. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 4 through
step 7 of this procedure, checking to ensure that the memory modules are firmly seated in their sockets.
14. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Cooling Fans
The system supports the following:
• An internal cooling fan
• An optional external cooling fan at the back of the chassis
NOTE: When selecting or upgrading your system configuration, verify the system power consumption with the Dell
Energy Smart Solution Advisor at dell.com/ESSA to ensure optimum power utilization.
Removing The Internal Cooling Fan
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: Never operate your system with the internal cooling fan removed. System can overheat and result in
shutdown of the system and loss of data.
CAUTION: Do not operate the system with the cover removed for a duration exceeding 5 minutes.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the cooling shroud.
5. Disconnect the internal cooling fan power cable from the system board.
6. Release the internal cooling fan power cable from the securing clips on the chassis and system board.
CAUTION: Do not remove or install the internal cooling fan by holding the blades.
7. Press the release tab on the internal cooling fan and, holding the internal cooling fan by the sides, slide it out in the
direction of the arrow marked on the fan.
78
Figure 39. Removing and Installing the Internal Cooling Fan
1. arrow
2. internal cooling fan
3. internal cooling fan power cable
4. release tab
Figure 40. Cabling—Internal Cooling Fan
1. FAN1 power connector on system board
2. internal cooling fan power cable
3. securing clip on system board
4. securing clip on chassis
79
5. internal cooling fan
Installing The Internal Cooling Fan
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: Do not operate the system with the cover removed for a duration exceeding 5 minutes.
1. Hold the system cooling fan by the sides with the cable end facing the bottom of the chassis.
CAUTION: Do not remove or install the internal cooling fan by holding the blades.
2. Align the four tabs of the internal cooling fan with the four slots on the inside of the chassis.
3. Press and slide the internal cooling fan into the slots till the release tab locks into place.
CAUTION: Do not remove or install the internal cooling fan by holding the blades.
4. Route the internal cooling fan power cable along the side of the chassis and secure the cable using the clips.
5. Connect the internal cooling fan power cable to the FAN1 connector on the system board.
6. Replace the cooling shroud.
7. Close the system.
8. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Removing The External Cooling Fan
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: Do not operate the system with the cover removed for a duration exceeding 5 minutes.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the cooling shroud.
5. Disconnect the external cooling fan power cable from the system board and free the power cable from the clips.
6. Remove the four screws that secure the external cooling fan to the chassis.
7. Rotate the top of the external cooling fan away from the system until the hooks are free of the slots and remove the
fan.
8. Remove the external cooling fan power cable from of the system through the slot in the back of the chassis.
9. Install the cooling shroud.
10. Close the system.
80
11. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
12. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Figure 41. Removing and Installing the External Cooling Fan
1. back of the system chassis
2. lower hooks (2)
3. external cooling fan
4. screws (4)
5. upper hook
6. external cooling fan power cable slot
7. external cooling fan power cable
Figure 42. Cabling—External Cooling Fan
1. external cooling fan power cable 2. securing clip on system board
81
3. FAN2 power connector on system board
4. securing clip on chassis
5. external cooling fan
Installing The External Cooling Fan
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: Do not operate the system with the cover removed for a duration exceeding 5 minutes.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the cooling shroud.
5. Route the external cooling fan power cable into the system through the slot at the back of the chassis.
6. Align and insert the two lower hooks on the external cooling fan into the corresponding slots on the back of the
chassis.
7. Rotate the top of the external cooling fan toward the chassis till the upper hook locks into place.
8. Use the four screws to secure the external cooling fan to the chassis.
9. Secure the external cooling fan power cable using the clips inside the chassis.
10. Connect the external cooling fan power cable to the FAN2 connector on the system board.
11. Install the cooling shroud.
12. Close the system.
13. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
14. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Internal USB Memory Key (Optional)
An optional USB memory key installed inside your system can be used as a boot device, security key, or mass storage
device. The USB connector must be enabled by the Internal USB Port option in the Integrated Devices screen of the
System Setup.
To boot from the USB memory key, configure the USB memory key with a boot image and then specify the USB memory
key in the boot sequence in the System Setup.
NOTE: To locate the internal USB connector (INT USB) on the system board, see System Board Connectors.
82
Replacing The Internal USB Key
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Locate the USB connector (INT USB) or the USB key on the system board.
5. If applicable, remove the USB key.
6. Insert the new USB key into the USB connector.
7. Close the system.
8. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
10. Enter the System Setup and verify that the USB key is detected by the system.
Figure 43. Replacing the Internal USB Key
1. USB key
83
2. USB connector
PCIe Card Holder (Optional)
Removing The PCIe Card Holder
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Press the tabs and pull the PCIe card holder from the chassis.
5. Lift the PCIe card holder out of the chassis.
6. Close the system.
7. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
8. If applicable, reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
Figure 44. Removing and Installing the PCIe Card Holder
84
1. slots (2)
2. tabs (2)
3. PCIe card holder
Installing The PCIe Card Holder
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Align the PCIe card holder with the slots on the chassis and push it down until seated.
5. Close the system.
6. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Expansion Cards
Expansion Card Installation Guidelines
Table 2. Supported PCI Express Expansion Cards
Expansion Card Slot Processor Connection Height Length Link Width Slot Width
1 Platform Controller Hub Full Height Half Length x4 x8
2 Platform Controller Hub Full Height Full Length x1 x8
3 Processor 1 Full Height Full Length x16 x16
4 Processor 1 Full Height Full Length x4 x8
6 Processor 1 Full Height Half Length x4 x8
NOTE: Slot 5 is not applicable.
NOTE: Only slot 3, 4, and 6 support Generation 3 PCIe expansion cards.
NOTE: The expansion cards are not hot-swappable.
The following table provides a guide for installing expansion cards to ensure proper cooling and mechanical fit. The
expansion cards with the highest priority must be installed first using the slot priority indicated. All other expansion
cards must be installed in card priority and slot priority order.
85
Table 3. Expansion Card Installation Order
Card Priority Card Type Slot Priority Maximum Allowed
1 GPU 3 1
2 External RAID 1, 4, 3, 6 1
3 Internal RAID 6, 4, 3, 1 1
4 10 Gb NICs 4, 3, 6 3
5 FC8 HBA 4, 3, 1, 6 4
6 CNAs 4, 3, 1, 6 4
7 1 Gb NICs 2, 4, 3, 1, 6 5
8 Non-RAID 4, 3, 1, 6 1
9 Internal tape adapter 2, 4, 3, 1, 6 1
NOTE: If you are installing a double-width GPU card in slot 3, you cannot install an expansion card in slot 2.
GPU Card Installation Guidelines
• Ensure that the GPU cable is available.
• The system supports one single- or double-width GPU card in PCIe slot 3.
• Only single-width GPU Q4000 and dual-width GPU Q6000 are supported.
• Systems installed with the double-width GPU card supports only one 5.25 inch removable media storage device.
• The GPU card must be installed on a system with a redundant 750 W AC power supply.
• The GPU card power cable must be connected to the GPU power connector CN11 on the power distribution board.
Removing An Expansion Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. If applicable, remove the PCIe card holder.
5. If applicable, press and disconnect the two SAS cables from the expansion card.
6. If applicable, disconnect the P3 power cable from the system board.
7. From inside the system, press and push out the expansion card release latch to open it.
8. Holding the card by its edge, pull the card to disengage from the connector and lift the card out of the chassis.
9. If you are removing the card permanently, install a filler bracket in the empty card slot.
86
NOTE: Filler brackets must be installed over empty expansion-card slots to maintain FCC certification of the
system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the
system.
10. From outside the system, rotate the expansion card latch toward the system until it snaps into place.
11. If applicable, install the PCIe card holder.
12. Close the system.
13. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
14. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Figure 45. Removing and Installing the Expansion Card
1. expansion card latch
2. expansion card connector
3. expansion card
Installing An Expansion Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Unpack the expansion card and prepare it for installation.
For instructions, see the documentation accompanying the card.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
4. Open the system.
87
5. If applicable, remove the PCIe card holder.
6. From inside the system, press and push out the expansion card release latch to open it.
7. If you are installing a new expansion card, remove the filler bracket.
NOTE: Keep the filler bracket in case you need to remove the expansion card. Filler brackets must be installed
over empty expansion-card slots to maintain FCC certification of the system. The brackets also keep dust and
dirt out of the system and aid in proper cooling and airflow inside the system.
8. Holding the card by its edges, position the card so that the card-edge connector aligns with the expansion card
connector.
9. Insert the card-edge connector into the expansion card connector until the card is fully seated.
10. From outside the system, rotate the expansion card latch toward the system until it snaps into place.
11. If applicable, connect the two SAS cables to the expansion card.
12. If applicable, connect the P3 power cable to the system board.
13. If applicable, install the PCIe card holder.
14. Close the system.
15. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
16. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Removing A GPU Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the PCIe card holder.
CAUTION: Do not use excessive force when removing the cables as it can damage the connectors.
5. Disconnect the cables from the GPU card.
6. From inside the system, press and push out the expansion card release latch securing the GPU card.
NOTE: If you are removing a double-width GPU card, you must open the two expansion card latches securing
the card.
7. Holding the card by its edge, pull the card to disengage from the connector and lift the card out of the chassis.
8. Install the filler brackets, if you are not replacing the GPU card.
NOTE: Filler brackets must be installed over empty expansion-card slots to maintain FCC certification of the
system. The brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the
system.
9. From outside the system, rotate the expansion card latch(es) toward the system until it snaps into place.
10. Install the PCIe card holder.
11. Close the system.
12. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
88
13. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Figure 46. Removing and Installing the GPU Card
1. GPU card (double-width)
2. SLI data connector
3. 6–pin GPU card power connector
4. 8–pin GPU card power connector
5. x16 connector
6. expansion-card latches (2)
Installing A GPU Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the PCIe card holder.
5. Locate the x16 slot on the system board.
6. From inside the system, press and push out the expansion card release latch for the x16 slot.
89
NOTE: If you are installing a double-width GPU card, you must open the two expansion card latches to secure
the card.
7. If applicable, remove the filler brackets.
8. Insert the GPU card into the x16 slot.
9. From outside the system, rotate the expansion card latch(es) toward the system until it snaps into place.
10. Connect the cables to the GPU card.
11. Install the PCIe card holder.
12. Close the system.
13. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
14. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
iDRAC Ports Card
The iDRAC ports card consists of the SD vFlash card slot and an iDRAC port. The iDRAC ports card is used for advanced
management of the system.
An SD vFlash card is a Secure Digital (SD) card that plugs into the SD vFlash card slot in the system. It provides
persistent on-demand local storage and a custom deployment environment that allows automation of server
configuration, scripts, and imaging. It emulates USB device(s). For more information, see the
iDRAC7 User's Guide
at
dell.com/support/manuals.
Removing The iDRAC Ports Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the cooling shroud.
5. Remove the screw securing the iDRAC ports card to the back of the chassis.
6. Pull the iDRAC ports card to disengage it from the iDRAC ports card connector and remove the card from the
chassis.
7. If you are not replacing the iDRAC ports card, insert the filler bracket and secure it with a screw.
NOTE: Filler brackets must be installed over empty card slots to maintain FCC certification of the system. The
brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside the system.
8. Install the cooling shroud.
9. Close the system.
10. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
11. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
90
Figure 47. Removing and Installing the iDRAC Ports Card
1. screw
2. iDRAC ports card
3. iDRAC ports card connector
Installing The iDRAC Ports Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the cooling shroud.
5. If there is a filler bracket in the iDRAC ports card slot, remove the screw and lift the filler bracket out of the system.
6. Insert the iDRAC ports card into the connector on the system board.
7. Secure the iDRAC ports card using the screw.
8. Install the cooling shroud.
91
9. Close the system.
10. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
11. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Replacing An SD vFlash Card
1. Locate the SD vFlash card slot on the system.
2. To remove the installed SD vFlash card, push inward on the card to release it, and pull the card from the card slot.
Figure 48. Removing and Installing the SD vFlash Card
1. SD vFlash card
2. SD vFlash card slot
3. To install the SD vFlash card, hold the card with the label side facing up and insert the contact-pin end of the card
into the SD vFlash card slot.
NOTE: The slot is keyed to ensure correct insertion of the card.
4. Press inward on the SD vFlash card to lock it into the slot.
Internal Dual SD Module
NOTE: When the Redundancy option is set to Mirror Mode in the Integrated Devices screen of the System Setup,
the information is replicated from one SD card to another.
Removing An Internal Dual SD Module
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Locate the internal dual SD module on the system board.
92
5. If applicable, remove the SD card(s).
6. Pull out the internal dual SD module from the system board.
7. Close the system.
8. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Figure 49. Removing and Installing the Internal Dual SD Module
1. SD card connector on system board
2. SD card slot 1
3. SD card slot 2
4. SD card
Installing An Internal Dual SD Module
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Locate the internal dual SD module connector on the system board.
5. Align the connectors on the system board with the connectors on the internal dual SD module.
6. Press the internal dual SD module until it is seated on the system board.
7. Close the system.
8. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
93
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Internal SD Card
Removing An Internal SD Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Locate the SD card slot on the internal dual SD module.
5. Press inward on the SD card to release it from the slot and remove the card.
6. Close the system.
7. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Installing An Internal SD Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: To use an SD card with your system, ensure that the Internal SD Card Port is enabled in the System Setup.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Locate the SD card slot on the internal dual SD module.
5. Orient the SD card appropriately and insert the contact-pin end of the card into the slot.
NOTE: The slot is keyed to ensure correct insertion of the card.
6. Press the card into the card slot to lock it into place.
7. Close the system.
8. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
94
Processors
Your system supports one of the following processors:
• One Intel Xeon processor E5-2400 product family
• One Intel Xeon processor E5-1410
• One Intel Pentium processor 1400
Use the procedures in this section to replace or upgrade your processor.
NOTE: When selecting or upgrading your system configuration, verify the system power consumption with the Dell
Energy Smart Solution Advisor at dell.com/ESSA to ensure optimum power utilization.
Removing A Processor
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If you are upgrading your system, download the latest system BIOS version from dell.com/support and follow the
instructions included in the compressed download file to install the update on your system.
NOTE: You can update the system BIOS using the Lifecycle Controller.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3. When disconnected from the power source, press and hold the power button for 3 seconds to fully drain the system
of stored power prior to removing the cover.
4. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
5. Open the system.
6. Remove the cooling shroud.
WARNING: The heat sink and processor are hot to the touch for some time after the system has been
powered down. Allow the heat sink and processor to cool before handling them.
CAUTION: Never remove the heat sink from a processor unless you intend to remove the processor. The heat
sink is necessary to maintain proper thermal conditions.
7. Loosen the first screw that secures the heat sink to the system board.
8. Wait 30 seconds for the heat sink to loosen from the processor and remove the screw diagonally opposite the first
screw.
9. Repeat steps 7 and 8 for the other pair of screws.
10. Lift the heat sink up from the processor and set the heat sink aside upside-down (thermal grease side facing up).
95
Figure 50. Removing and Installing the Heat Sink
1. heat sink
2. captive screws (4)
3. processor shield
4. standoffs (4)
CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can
spring up suddenly if not firmly grasped.
11. Position your thumb firmly over the processor socket-release lever and release the lever from the locked position
by pushing down and out from under the tab. Rotate the lever 90 degrees upwards.
12. Rotate the processor shield upward and out of the way.
CAUTION: The socket pins are fragile and can be permanently damaged. Be careful not to bend the pins in the
socket when removing the processor out of the socket.
13. Lift the processor out of the socket and leave the release lever up so that the socket is ready for the new
processor.
96
Figure 51. Removing and Installing a Processor
1. socket release lever
2. processor
3. processor shield
4. ZIF socket
5. socket keys (2)
6. notch
NOTE: After removing the processor, place it in an antistatic container for reuse, return, or temporary storage.
Do not touch the bottom of the processor. Touch only the edges of the processor.
Installing A Processor
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If you are upgrading your system, download the latest system BIOS version from dell.com/support and follow the
instructions included in the compressed download file to install the update on your system.
NOTE: You can update the system BIOS using the Lifecycle Controller.
2. Unpack the new processor.
If the processor has previously been used in a system, remove any remaining thermal grease from the processor
using a lint-free cloth.
3. Align the processor with the socket keys on the ZIF socket.
4. To install the processor in the socket:
97
CAUTION: Positioning the processor incorrectly can permanently damage the system board or the processor.
Be careful not to bend the pins in the socket.
a) With the release lever on the processor socket in the open position, align the processor with the socket keys
and set the processor lightly in the socket.
CAUTION: Do not use force to seat the processor. When the processor is positioned correctly, it engages
easily into the socket.
b) Close the processor shield.
c) Rotate the socket release lever down until it snaps into place.
5. Install the heat sink:
CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and
contaminating the processor socket.
a) If applicable, open the grease applicator included with your processor kit and apply all of the thermal grease in
the applicator to the center of the topside of the new processor.
b) Place the heat sink onto the processor.
c) Tighten the four screws to secure the heat sink to the system board.
NOTE: Do not over-tighten the heat sink retention screws when installing the heat sink. To prevent over-
tightening, tighten the retention screw until resistance is felt, and stop once the screw is seated. The
screw tension should be no more than 6 in-lb (6.9 kg-cm).
6. Install the cooling shroud.
7. Close the system.
8. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
10. Press <F2> to enter the System Setup and check that the processor information matches the new system
configuration.
11. Run the system diagnostics to verify that the new processor operates correctly.
Redundant AC Power Supply
Your system supports up to two 495 W or 750 W redundant AC power supplies.
When two identical power supplies are installed, the power supply configuration is redundant (1 + 1). In redundant
mode, power is supplied to the system equally from both power supplies to maximize efficiency.
When only one power supply is installed, the power supply configuration is non-redundant (1 + 0). Power is supplied to
the system only by the single power supply.
NOTE: If two power supplies are used, they must be of the same type and have the same maximum output power.
NOTE: Redundant power supplies are supported on systems with hot-swappable hard drives only.
NOTE: When selecting or upgrading your system configuration, verify the system power consumption with the Dell
Energy Smart Solution Advisor at dell.com/ESSA to ensure optimum power utilization.
Removing A Redundant AC Power Supply
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
98
CAUTION: The system requires at least one power supply for normal operation. On power-redundant systems,
remove and replace only one power supply at a time in a system that is powered on.
NOTE: For systems in rack mode, you may have to unlatch and lift the optional cable management arm if it
interferes with power supply removal. For information about the cable management arm, see the system’s rack
documentation.
1. Disconnect the power cable from the power source.
2. Remove the power cables from the cable strap of the power supply that you intend to remove.
3. Disconnect the power cable from the power supply.
4. Press the release latch and slide the power supply out of the chassis.
Figure 52. Removing and Installing a Redundant AC Power Supply
1. connector
2. redundant AC power supply
3. release latch
4. power supply handle
Installing A Redundant AC Power Supply
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Verify that both the power supplies are the same type and have the same maximum output power.
NOTE: The maximum output power (shown in Watts) is listed on the power supply label.
2. If applicable, remove the power supply blank.
3. Slide the new power supply into the chassis until the power supply is fully seated and the release latch snaps into
place.
NOTE: The systems configured in rack-mode, re-latch the cable management arm if you unlatched it. For
information about the cable management arm, see the system’s rack documentation.
99
4. Connect the power cable to the power supply and plug the cable into a power outlet.
CAUTION: When connecting the power cable, secure the cable with the cable strap.
NOTE: When installing, hot-swapping, or hot-adding a new power supply, allow several seconds for the
system to recognize the power supply and determine its status. The power-supply status indicator or handle
turns green to signify that the power supply is functioning properly.
Removing The Power Supply Blank
CAUTION: To ensure proper system cooling, the power supply blank must be installed in the second power supply
bay in a non-redundant configuration. Remove the power supply blank only if you are installing a second power
supply.
If you are installing a second power supply, remove the power supply blank in the bay by pulling outward on the
blank.
Figure 53. Removing and Installing the Power Supply Blank
1. power supply blank
Installing The Power Supply Blank
NOTE: Install the power supply blank only in the second power supply bay.
To install the power supply blank, align the blank with the power supply bay and insert it into the chassis until it clicks
into place.
100
Replacing The Power Supply Divider
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. Remove the redundant power supply module(s) or power supply blank as applicable.
3. Remove the screw securing the power-supply divider to the chassis.
4. Slide out the power-supply divider and rotate clockwise to free the tabs on the power-supply divider from the slots
of the power supply unit cage .
5. Slide the power-supply divider out of the chassis.
6. Align the tabs of the new power-supply divider with the slots of the power supply unit cage .
7. Rotate the power-supply divider counter-clockwise and slide it in until the power-supply divider is seated in the
slots of the power supply unit cage .
8. Secure the power supply divider to the chassis using the screw.
9. Install the redundant power supply module(s) or power supply blank as applicable.
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Figure 54. Removing and Installing the Power-Supply Divider
1. power supply divider
2. tabs (4)
101
3. screw
Non-Redundant AC Power Supply
Your system supports a non-redundant 350 W AC power supply.
NOTE: Non-redundant power supply is supported in systems with cabled hard drives and systems with an x8
backplane.
NOTE: When selecting or upgrading your system configuration, verify the system power consumption with the Dell
Energy Smart Solution Advisor at dell.com/ESSA to ensure optimum power utilization.
Removing A Non-Redundant AC Power Supply
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Disconnect the power cable from the power source.
4. Disconnect the power cable from the power supply and remove the power cables from the cable strap.
5. Open the system.
6. Disconnect all the power cables from the power supply to the system board, hard-drive backplane, hard drives, and
optical drives, as applicable.
7. Remove the screw securing the power supply to the chassis and slide the power supply out of the power supply
unit cage.
102
Figure 55. Removing and Installing a Non-Redundant AC Power Supply
1. screw
2. power supply unit cage
3. non-redundant power supply
4. standoff on the chassis
5. P1 cable connector
6. P2 cable connector
7. P3 cable connector
8. backplane connector
103
Installing A Non-Redundant AC Power Supply
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Unpack the new power supply.
2. Open the system.
3. Slide the new power supply into the power supply unit cage until the power supply is fully seated.
4. Tighten the screw to secure the power supply to the chassis.
5. Connect all the power cables to the system board, hard-drive backplane, hard drives, and optical drives, as
applicable.
6. Close the system.
7. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Power Distribution Board And Power Interposer Board
The power distribution board and the power interposer board are only supported in systems with redundant power
supplies.
NOTE: The power distribution board is installed on the power interposer board and then installed into the system.
Removing The Power Interposer Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
CAUTION: To prevent damage to the power interposer board, you must remove the power supply module(s) or
power supply blank from the system before removing the power interposer board or power distribution board.
2. Remove the power supply module(s) or power supply blank from the back of the chassis.
3. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
4. Open the system.
5. Disconnect the power cables from the hard-drive backplane and the system board.
NOTE: If applicable, remove the expansion card to enable removing the P3 power cable from the system
board.
6. Remove the four screws securing the power distribution board to the chassis.
7. Press the release latch on the power interposer board to release the power interposer board from the hooks on the
power supply unit cage.
8. Lift the power interposer board along with the power distribution board up and out of the chassis.
104
Figure 56. Removing and Installing the Power Interposer Board and the Power Distribution Board
1. power distribution board
2. slots on power interposer board (4)
3. GPU power connector
4. power interposer board
5. hooks (4)
6. release latch
7. P6 cable connector
8. P1 cable connector
9. P2 cable connector
10. P3 cable connector
11. GPU power connector
12. backplane connector
13. screws (4)
105
Installing The Power Interposer Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If applicable, install the power distribution board onto the power interposer board.
2. Align the power interposer board with the hooks on the power supply cage and slide it into place.
3. Install the four screws that secure the power distribution board to the chassis.
4. Route the power cables through the securing clips as applicable, and connect the power cables to the system
board.
5. Route the P3 power cable through the securing clip on the system board and connect power cable to the hard-
drive backplane.
6. Install the power supply module(s) or power supply blank in their original locations.
7. Close the system.
8. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
Replacing The Power Distribution Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Remove the power interposer board and the power distribution board together from the system.
2. Slide out the power distribution board from the power interposer board and replace with the new power
distribution board.
3. Install the power interposer board and the power distribution board together in the system.
System Battery
Replacing The System Battery
WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with
the same or equivalent type recommended by the manufacturer. See your safety information for additional
information.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
106
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Locate the battery socket.
CAUTION: To avoid damage to the battery connector, you must firmly support the connector while installing or
removing a battery.
5. To remove the battery, support the battery connector by pressing down firmly on the positive side of the connector.
Figure 57. Removing and Installing the System Battery
1. positive side of battery connector
2. system battery
6. Lift the battery out of the securing tabs at the negative side of the connector.
7. To install a new system battery, support the battery connector by pressing down firmly on the positive side of the
connector.
8. Hold the battery with the "+" facing up and slide it under the securing tabs at the positive side of the connector.
9. Press the battery straight down into the connector until it snaps into place.
10. Install the cooling shroud.
11. Close the system.
12. If applicable, place the system upright on a flat, stable surface and turn the system feet outward.
13. Reconnect the system to the electrical outlet and turn the system on, including any attached peripherals.
14. Enter the System Setup to confirm that the battery is operating properly.
15. Enter the correct time and date in the System Setup Time and Date fields.
16. Exit the System Setup.
Control-Panel Assembly
The control-panel assembly consists of the following:
• Control-panel board
• Control panel with LCD module or diagnostic indicators
• VGA module (For systems in rack mode only)
107
The control-panel assembly with diagnostic indicators is supported on systems with cabled hard drives and systems
with an x8 backplane. The control-panel assembly with LCD module is supported on systems with hot-swappable hard
drives only.
Removing The Control-Panel Assembly
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3. Open the system.
4. Remove the screw on the side of the chassis that secures the control-panel assembly to the chassis.
5. Slide the control-panel assembly out of the chassis.
CAUTION: Do not use excessive force when removing the control panel cable as it can damage the
connectors.
6. Remove the control panel cable and if applicable, the VGA module cable from the control-panel assembly.
NOTE: Ensure that the control panel cable and if applicable, the VGA module cable, does not slip back into the
chassis.
Figure 58. Removing and Installing the Control-Panel assembly With an LCD Module in a Tower-Mode System
1. LCD module ZIF connector 2. control-panel assembly connector
108
3. control-panel assembly cable connector
4. screw
5. control-panel assembly
6. control panel
Figure 59. Removing and Installing the Control-Panel Assembly With Diagnostic Indicators in a Tower-Mode System
1. control panel board
2. control-panel assembly connector
3. control-panel assembly cable connector
4. screw
109
Figure 60. Removing and Installing the Control-Panel Assembly in a Rack-Mode System
1. LCD module ZIF connector
2. VGA module connector
3. VGA module cable connector
4. control-panel assembly connector
5. control-panel assembly cable connector
6. screw
7. control-panel board
8. VGA module
9. control panel for rack mode
7. If you are replacing the control-panel assembly, remove the information tag by following the steps below:
a) Locate the tabs on the information tag.
b) Use a flat screwdriver to press the tabs on the tag one at a time.
c) Pull the information tag out of the slot to remove it from the control-panel assembly.
NOTE: Retain the information tag for replacement in the new control-panel assembly.
Figure 61. Removing and Installing the Information Tag
1. information tag
2. tabs (2)
110
3. slot
Installing The Control-Panel Assembly
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Connect the control panel cable and if applicable, the VGA module cable to the control-panel assembly.
2. Align and insert the control-panel assembly into the slot in the chassis.
NOTE: Ensure that you do not crimp the cables as you insert the control-panel assembly into the slot.
3. Push the control-panel assembly so that it is flush with the back of the slot in the chassis.
4. Secure the control-panel assembly to the chassis using the screw on the side of the chassis.
5. Replace the blank information tag in the new control panel with the information tag retained from the old control
panel.
NOTE: Information tag lists system information such as Service Tag, NIC, MAC address, and so on.
6. Close the system.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
8. If applicable, install the front bezel.
Removing The Control Panel
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3. Offset the control panel from the control-panel assembly.
4. Slide the control panel out of the control-panel assembly.
111
Figure 62. Removing and Installing the Control Panel for Systems With an LCD Module
1. control panel
2. control-panel board
3. LCD module
4. control-panel assembly
5. tabs (3)
Figure 63. Removing and Installing the Control Panel for Systems With Diagnostic Indicators
1. control panel
2. control-panel board
112
3. control-panel assembly
4. tabs (3)
Installing The Control Panel
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Align the three tabs on the inside of the control panel with the slots on the control-panel assembly.
2. Slide the control panel into the control-panel assembly until it locks into place.
3. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
4. If applicable, install the front bezel.
Removing The Control-Panel Board For Systems With LCD Modules
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3. Open the system.
4. Remove the control-panel assembly.
5. Remove the three screws securing the control-panel board to the control-panel assembly.
6. Remove the LCD ZIF cable from the LCD module ZIF connector on the control-panel board.
NOTE: The LCD module connector is a ZIF (zero insertion force) connector. Ensure that the locking tab on the
connector is released before removal and insertion. The locking tab must be engaged after insertion.
7. Lift the control-panel board away from the control-panel assembly.
8. If you are replacing the control-panel board in a system in rack mode, remove the VGA module from the control-
panel board.
113
Figure 64. Removing and Installing the Control-Panel Board With LCD Module
1. LCD ZIF cable
2. LCD module ZIF connector
3. control-panel board
4. screws (3)
5. control-panel assembly
Installing The Control-Panel Board For Systems With LCD Modules
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Using the screw holes, align the control-panel board with the control-panel assembly.
2. Secure the control-panel board to the control-panel assembly using the three screws.
3. Connect the LCD ZIF cable to the LCD module ZIF connector on the control-panel board.
NOTE: The LCD module connector is a ZIF (zero insertion force) connector. Ensure that the locking tab on the
connector is released before removal and insertion. The locking tab must be engaged after insertion.
4. If you are replacing the control-panel board in a system in rack mode, install the VGA module on the control-panel
board.
5. Install the control-panel assembly in the chassis.
6. Close the system.
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
8. If applicable, install the front bezel.
114
Removing The Control-Panel Board For Systems With Diagnostic Indicators
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: The control-panel assembly with diagnostic indicators is supported on systems with cabled hard drives and
systems with an x8 backplane.
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3. Open the system.
4. Remove the control-panel assembly.
5. Remove the three screws securing the control-panel board to the control-panel assembly.
6. Lift the control-panel board away from the control-panel assembly.
Figure 65. Removing and Installing the Control-Panel Board With Diagnostic Indicators
1. control-panel board
2. screws (3)
3. control-panel assembly
115
Installing The Control-Panel Board For Systems With Diagnostic Indicators
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: The control-panel assembly with diagnostic indicators is supported on systems with cabled hard drives and
systems with an x8 backplane.
1. Using the screw holes, align the control-panel board with the control-panel assembly.
2. Secure the control-panel board to the control-panel assembly using the three screws.
3. Install the control-panel assembly in the chassis.
4. Close the system.
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
6. If applicable, install the front bezel.
Removing The LCD Module
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3. Open the system.
4. Remove the control-panel assembly.
5. Remove the control panel from the control-panel assembly.
6. Remove the LCD ZIF cable from the LCD module ZIF connector on the control-panel board.
NOTE: The LCD module connector is a ZIF (zero insertion force) connector. Ensure that the locking tab on the
connector is released before removal and insertion. The locking tab must be engaged after insertion.
7. Remove the screw connecting the LCD module to the control-panel assembly and slide out the LCD module.
116
Figure 66. Removing and Installing the LCD Module
1. LCD module
2. screw
3. LCD module ZIF connector
4. LCD ZIF cable
Installing The LCD Module
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Align and insert the LCD module with the LCD module slot on the control-panel assembly.
2. Secure the LCD module into the control-panel assembly using the screw.
3. Connect the LCD ZIF cable to the LCD module ZIF connector on the control-panel board.
NOTE: The LCD module connector is a ZIF (zero insertion force) connector. Ensure that the locking tab on the
connector is released before removal and insertion. The locking tab must be engaged after insertion.
4. Install the control-panel board on the control-panel assembly.
5. Install the control-panel assembly into the chassis.
6. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
7. If applicable, install the front bezel.
117
Removing The VGA Module—Rack Mode
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If installed, remove the front bezel.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3. Open the system.
4. Remove the control panel assembly.
5. Lift the VGA module from the securing tabs on the control-panel board.
6. Remove the VGA cable from the control-panel assembly.
Figure 67. Removing and Installing the VGA Module
1. control panel
2. control-panel board
3. VGA module
4. securing tabs (2)
5. control-panel assembly
118
Installing The VGA Module—Rack Mode
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Align the VGA module with the securing tabs on the control-panel board.
2. Install the VGA module by pressing down the VGA module until it is fully seated in the securing tabs.
3. Connect the VGA cable to the control-panel assembly.
4. Install the control panel for rack mode in the control-panel assembly.
5. Install the control-panel assembly.
6. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
7. If applicable, install the front bezel.
System Board
Removing The System Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: If you are using the Trusted Program Module (TPM) with an encryption key, you may be prompted to
create a recovery key during program or system setup. Be sure to create and safely store this recovery key. If you
replace this system board, you must supply the recovery key when you restart your system or program before you
can access the encrypted data on your hard drives.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. Open the system.
4. Remove the following as applicable:
a) cooling shroud
b) system cooling fan
c) PCIe card holder
d) iDRAC ports card
e) all expansion cards
WARNING: The heat sink and processor are hot to the touch for some time after the system has been
powered down. Allow the heat sink and processor to cool before handling them.
f) heat sink and processor
g) memory modules
h) internal dual SD module
i) internal USB key
119
5. Disconnect all cables from the system board.
CAUTION: Take care not to damage the system identification button while removing the system board from
the chassis.
6. Remove the 11 screws that secure the system board to the chassis.
7. Grasp the system-board holders and slide the system board towards the front of the system.
CAUTION: Do not lift the system board assembly by grasping a memory module, processor, or other
components.
Figure 68. Removing the System Board
1. screws (11)
2. system-board holders (2)
3. system board
Installing The System Board
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
120
CAUTION: If you are using the Trusted Program Module (TPM) with an encryption key, you may be prompted to
create a recovery key during program or system setup. Be sure to create and safely store this recovery key. If you
replace this system board, you must supply the recovery key when you restart your system or program before you
can access the encrypted data on your hard drives.
1. Unpack the new system board assembly.
CAUTION: Do not lift the system board assembly by grasping a memory module, processor, or other
components.
2. Using the system-board holders, lower the system board into the chassis while aligning the guiding slot on the
system board with the tab in the chassis.
NOTE: The guiding slot on the system board is located on the edge of the system board and near the memory
modules.
3. Push the system board towards the back of the chassis until the system board clicks into place.
4. Secure the system board to the chassis using the eleven screws.
NOTE: It is recommended that you install screws from diagonally opposite corners.
5. Install the following, as applicable:
a) heat sink and processor
b) memory modules
c) internal dual SD module
d) internal USB key
e) expansion cards
f) iDRAC ports card
g) PCIe card holder
h) system cooling fan
i) cooling shroud
6. Reconnect all cables to the system board.
7. Close the system.
8. If applicable, place the system upright on a flat, stable surface and rotate the system feet outward.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
10. Import your new or existing iDRAC Enterprise license. For more information, see
iDRAC7 User's Guide
, at dell.com/
support/manuals.
121
122
4
Converting The System From Tower Mode To
Rack Mode
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: Only systems with hot-swappable hard drives are rackable.
Safety Instructions
NOTE: For specific caution statements and procedures, see the rack installation documentation that shipped with
your system and the rack kit. For complete safety and regulatory information, see the safety instructions that
shipped with your system.
Observe the following precautions for stability and safety of the system in rack mode:
• Your rack kit has been approved only for the rack cabinet provided. Ensure that installation of the equipment into any
other rack complies with all applicable standards. Dell disclaims all liability and warranties with respect to
combinations of equipment with any other rack.
• Before installing your equipment in a rack, install all front and side stabilizers. Failure to install stabilizers can allow
the rack to tip over.
• Always load from the bottom up, and load the heaviest items first.
• Do not overload the AC power supply branch circuit that provides power to the rack.
• Do not stand or step on any components in the rack.
Preparing A System For Conversion From Tower Mode To Rack
Mode
You require the following items to convert your system from tower to rack mode:
• Rack ears (left and right) with three screws each
• VGA module
• Control panel for rack mode
• #2 Phillips screwdriver
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
2. If applicable, rotate the system feet inward and lay the system on its side on a flat, stable surface.
NOTE: For systems installed with the wheel assembly, ensure that you lay the system on a sturdy, stable
surface with the wheel assembly extending off the edge of the surface.
3. If applicable, remove the system feet or wheel assembly.
123
4. Open the system.
5. Remove the system top cover by following the steps below:
a) Using a #2 Phillips screwdriver, remove the three screws on the side of the system that secure the system top
cover to the system chassis.
b) Slide the top panel toward the back of the system until the panel hooks clear the chassis slots.
c) Rotate the free side of the panel outward about 15 degrees and pull the panel clear of the system.
Figure 69. Removing and Installing The System Top Cover
1. system top cover
2. screws (3)
6. Remove the control panel assembly from the chassis.
7. Remove the control panel for tower mode from the control panel assembly.
8. Install the VGA module on the control panel assembly.
9. Install the control panel for rack mode.
10. Install the control panel assembly into the chassis.
11. To attach the rack ears, follow the steps below:
a) Align the three screw holes on the right rack ear with the screw holes on the right side of the rack system.
b) Install the three screws using a #2 Phillips screwdriver.
c) Repeat step a and step b to install the left rack ear.
124
Figure 70. Removing and Installing the Rack Ears
1. front panel
2. rack ears (2)
3. screws for each rack ear (3)
12. Close the system.
Rack Installation
To install the system in a rack, see the system’s Rack Installation Guide.
125
126
5
Troubleshooting Your System
Safety First—For You And Your System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
Troubleshooting System Startup Failure
If you boot the system to the BIOS boot mode after installing an operating system from the UEFI Boot Manager, the
system hangs. The reverse is also true. You must boot to the same boot mode in which you installed the operating
system.
For all other startup issues, note the system messages that appear on the screen.
Troubleshooting External Connections
Ensure that all external cables are securely attached to the external connectors on your system before troubleshooting
any external devices.
Troubleshooting The Video Subsystem
1. Check the system and power connections to the monitor.
2. Check the video interface cabling from the system to the monitor.
3. Run the appropriate diagnostic test.
If the tests run successfully, the problem is not related to video hardware.
If the tests fail, see Getting Help.
Troubleshooting A USB Device
Use the following steps to troubleshoot a USB keyboard/mouse. For other USB devices, go to step 7.
1. Disconnect the keyboard and mouse cables from the system briefly and reconnect them.
2. Connect the keyboard/mouse to the USB port(s) on the opposite side of the system.
3. If the problem is resolved, restart the system, enter the System Setup, and check if the non-functioning USB ports
are enabled.
4. Replace the keyboard/mouse with another working keyboard/mouse.
5. If the problem is resolved, replace the faulty keyboard/mouse.
6. If the problem is not resolved, proceed to the next step to begin troubleshooting the other USB devices attached to
the system.
127
7. Power down all attached USB devices and disconnect them from the system.
8. Restart the system and, if your keyboard is functioning, enter the System Setup. Verify that all USB ports are
enabled on the Integrated Devices screen, in the System Setup options.
If your keyboard is not functioning, you can also use remote access. If the system is not accessible, reset the
NVRAM_CLR jumper inside your system and restore the BIOS to the default settings.
9. Reconnect and power on each USB device one at a time.
10. If a device causes the same problem, power down the device, replace the USB cable with a known good cable, and
power up the device.
If all troubleshooting fails, see Getting Help.
Troubleshooting A Serial I/O Device
1. Turn off the system and any peripheral devices connected to the serial port.
2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.
If the problem is resolved, replace the interface cable with a known good cable.
3. Turn off the system and the serial device, and swap the device with a comparable device.
4. Turn on the system and the serial device.
If the problem persists, see Getting Help.
Troubleshooting A NIC
1. Run the appropriate diagnostic test. See Using System Diagnostics for available diagnostic tests.
2. Restart the system and check for any system messages pertaining to the NIC controller.
3. Check the appropriate indicator on the NIC connector:
– If the link indicator does not light, check all cable connections.
– If the activity indicator does not light, the network driver files might be damaged or missing.
Remove and reinstall the drivers if applicable. See the NIC's documentation.
– If applicable, change the autonegotiation setting.
– Use another connector on the switch or hub.
4. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.
5. Enter the System Setup and confirm that the NIC ports are enabled on the Integrated Devices screen.
6. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed and
duplex. See the documentation for each network device.
7. Ensure that all network cables are of the proper type and do not exceed the maximum length.
If all troubleshooting fails, see Getting Help.
128
Troubleshooting A Wet System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2. Open the system.
3. Disassemble components from the system:
– Hard drives
– Hard-drive backplane
– USB memory key
– Cooling shroud
– Expansion-card risers (if present)
– Expansion cards
– Power supply(s)
– Cooling fans
– Processor and heat sink
– Memory modules
4. Let the system dry thoroughly for at least 24 hours.
5. Reinstall the components you removed in step 3.
6. Close the system.
7. Turn on the system and attached peripherals.
If the system does not start properly, see Getting Help.
8. If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed.
9. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
If the tests fail, see Getting Help.
Troubleshooting A Damaged System
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2. Open the system.
3. Ensure that the following components are properly installed:
– Cooling shroud
– Expansion-card risers (if present)
– Expansion cards
– Power supply(s)
– Cooling fans
129
– Processor and heatsink
– Memory modules
– Hard-drive carriers
– Hard-drive backplane
4. Ensure that all cables are properly connected.
5. Close the system.
6. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
If the tests fail, see Getting Help.
Troubleshooting The System Battery
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system
configuration information. This situation is caused by a defective battery.
1. Re-enter the time and date in the System Setup.
2. Turn off the system and disconnect it from the electrical outlet for at least one hour.
3. Reconnect the system to the electrical outlet and turn on the system.
4. Enter the System Setup.
If the date and time are not correct in the System Setup, check the SEL for system battery messages.
If the problem is not resolved, see Getting Help.
NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate
normally except for the time kept in the System Setup, the problem may be caused by software rather than by a
defective battery.
Troubleshooting A Non-Redundant Power Supply
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Press the self-diagnostic button on the power supply.
2. If the power supply status indicator is not lit, turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
3. Open the system.
4. Reseat the power supply and the cables.
5. Close the system.
6. If the problem persists, see Getting Help.
130
Troubleshooting Redundant Power Supplies
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Reseat the power supply by removing and reinstalling it.
NOTE: After installing a power supply, allow several seconds for the system to recognize the power supply
and to determine if it is working properly.
2. If the problem persists, see Getting Help.
Troubleshooting Cooling Problems
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
Ensure that none of the following conditions exist:
• System cover, cooling shroud, EMI filler panel, memory-module blank, or back-filler bracket is removed.
• Ambient temperature is too high.
• External airflow is obstructed.
• A cooling fan is removed or has failed.
• The expansion card installation guidelines have not been followed.
Troubleshooting Cooling Fans
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Open the system.
2. Reseat the fan or the fan's power cable.
3. If the fan functions properly, close the system.
If the problem persists, see Getting Help.
Troubleshooting System Memory
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. If the system is operational, run the appropriate diagnostic test. See Using System Diagnostics for available
diagnostic tests.
131
If diagnostics indicates a fault, follow the corrective actions provided by the diagnostic program.
2. If the system is not operational, turn off the system and attached peripherals, and unplug the system from the
power source. Wait at least 10 seconds and then reconnect the system to power.
3. Turn on the system and attached peripherals and note the messages on the screen.
If an error message is displayed indicating a fault with a specific memory module, go to step 12.
4. Enter the System Setup and check the system memory setting. Make any changes to the memory settings, if
needed.
If the memory settings match the installed memory but a problem is still indicated, go to step 12.
5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6. Open the system.
7. Check the memory channels and ensure that they are populated correctly.
8. Reseat the memory modules in their sockets.
9. Close the system.
10. Enter the System Setup and check the system memory setting.
If the problem is not resolved, proceed with the next step.
11. Open the system.
12. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module
with a known good memory module.
13. To troubleshoot an unspecified faulty memory module, replace the memory module in the first DIMM socket with a
module of the same type and capacity.
If an error message is displayed on the screen, this may indicate a problem with the installed DIMM type(s),
incorrect DIMM installation, or defective DIMM(s). Follow the on-screen instructions to resolve the problem. For
more information, see General Memory Module Installation Guidelines.
14. Close the system.
15. As the system boots, observe any error message that is displayed and the diagnostic indicators on the front of the
system.
16. If the memory problem is still indicated, repeat step 12 through step 15 for each memory module installed.
If the problem persists after all memory modules have been checked, see Getting Help.
Troubleshooting An Internal USB Key
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Enter the System Setup and ensure that the USB key port is enabled from the Integrated Devices screen.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Open the system.
4. Locate the USB key and reseat it.
5. Close the system.
6. Turn on the system and attached peripherals and check if the USB key is functioning.
7. If the problem is not resolved, repeat step 2 and step 3.
8. Insert a different USB key that you know works properly.
9. Close the system.
132
If the problem is not resolved, see Getting Help.
Troubleshooting An SD Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: Certain SD cards have a physical write-protect switch on the card. If the write-protect switch is turned on
then the SD card is not writeable.
1. Enter the System Setup and ensure that the Internal SD Card Port is enabled.
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3. Open the system.
CAUTION: If the Internal SD Card Redundancy option is set to Mirror Mode in the Integrated Devices screen
of the System Setup, you must follow the instructions in step 4 through step 7 to avoid loss of data.
NOTE: When an SD card failure occurs, the internal dual SD module controller notifies the system. On the next
reboot, the system displays a message indicating the failure.
4. If the Internal SD Card Redundancy option is set to Disabled, replace the failed SD card with a new SD card.
5. If SD card 1 has failed, remove the card from SD card slot 1. If SD card 2 has failed, install a new SD card in SD
card slot 2 and proceed to step 7.
6. Remove the card present in SD card slot 2 and insert it into SD card slot 1.
7. Insert the new SD card into SD card slot 2.
8. Close the system.
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
10. Enter the System Setup and ensure that the Internal SD Card Port and Internal SD Card Redundancy mode is
enabled.
11. Check if the SD card is functioning properly.
If the problem persists, see Getting Help.
Troubleshooting An Optical Or Tape Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Try using a different CD or DVD.
2. Enter the System Setup and ensure that the integrated SATA controller and the drive's SATA port are enabled.
3. Run the appropriate diagnostic test.
4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
5. Open the system.
6. Remove the front bezel.
7. Ensure that the interface cable is securely connected to the drive and to the controller.
8. Ensure that a power cable is properly connected to the drive.
9. Close the system.
133
If the problem is not resolved, see Getting Help.
Troubleshooting A Hard Drive
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
CAUTION: This troubleshooting procedure can erase data stored on the hard drive. Before you proceed, back up
all files on the hard drive.
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Depending on the results of the diagnostics test, proceed as needed through the following steps.
2. If your system has a RAID controller and your hard drives are configured in a RAID array, perform the following
steps:
a) Restart the system and press <F10> during system startup to run the Lifecycle Controller, and then run the
Hardware Configuration wizard to check the RAID configuration.
See the Lifecycle Controller documentation or online help for information on RAID configuration.
b) Ensure that the hard drive(s) have been configured correctly for the RAID array.
c) Take the hard drive offline and reseat the drive.
d) Exit the configuration utility and allow the system to boot to the operating system.
3. Ensure that the required device drivers for your controller card are installed and are configured correctly. See the
operating system documentation for more information.
4. Restart the system and enter the System Setup.
5. Verify that the controller is enabled and the drives are displayed in the System Setup.
If the problem persists, try troubleshooting the expansion cards or see Getting Help.
Troubleshooting Expansion Cards
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the
expansion card.
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Open the system.
4. Ensure that each expansion card is firmly seated in its connector.
5. Close the system.
6. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the
electrical outlet.
7. Open the system.
8. Remove all expansion cards installed in the system.
9. Close the system.
134
10. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
If the tests fail, see Getting Help.
11. For each expansion card you removed in step 8, perform the following steps:
a) Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
b) Open the system.
c) Reinstall one of the expansion cards.
d) Close the system.
e) Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
If a problem is still indicated, see Getting Help.
Troubleshooting Processor
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Run the appropriate diagnostics test. See Using System Diagnostics for available diagnostic tests.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Open the system.
4. Ensure that the processor and heat sink are properly installed.
5. Close the system.
6. Run the appropriate diagnostic test. For more information , see Using System Diagnostics.
If a problem is still indicated, see Getting Help.
135
136
6
Using System Diagnostics
If you experience a problem with your system, run the system diagnostics before contacting Dell for technical
assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional
equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the
diagnostics results to help you solve the problem.
Dell Online Diagnostics
Dell Online Diagnostics, a stand-alone suite of diagnostic programs or test modules, allows you to run diagnostic tests
on the systems in a production environment, and helps you ensure maximum uptime of your systems. Online Diagnostics
allows you to run diagnostic tests on chassis and storage components such as hard drives, physical memory, and
network interface cards (NICs). You can use the graphical user interface (GUI) or the command line interface (CLI) to run
diagnostic tests on the hardware that Online Diagnostics discovers on your system. For information about using
diagnostics, see the
Dell Online PowerEdge Diagnostics User’s Guide
under Software → Serviceability Tools, at
dell.com/support/manuals.
Dell Embedded System Diagnostics
NOTE: Also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics.
The embedded system diagnostics provides a set of options for particular device groups or devices allowing you to:
• Run tests automatically or in an interactive mode
• Repeat tests
• Display or save test results
• Run thorough tests to introduce additional test options to provide extra information about the failed device(s)
• View status messages that inform you if tests are completed successfully
• View error messages that inform you of problems encountered during testing
When To Use The Embedded System Diagnostics
If a major component or device in the system does not operate properly, running the embedded system diagnostics may
indicate component failure.
Running The Embedded System Diagnostics
The embedded system diagnostics program is run from the Dell Lifecycle Controller.
CAUTION: Use the embedded system diagnostics to test only your system. Using this program with other systems
may cause invalid results or error messages.
1. As the system boots, press <F11>.
2. Use the up and down arrow keys to select System Utilities → Launch Dell Diagnostics .
137
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The
diagnostics starts executing the tests on all the detected devices.
System Diagnostic Controls
Menu Description
Configuration Displays the configuration and status information of all detected devices.
Results Displays the results of all tests that are executed.
System Health Provides the current overview of the system performance.
Event Log Displays a time-stamped log of the results of all tests run on the system. This is displayed if at
least one event description is recorded.
For information about embedded system diagnostics, see the
Dell Enhanced Pre-boot System Assessment User Guide
at
dell.com/support/manuals.
138
7
Jumpers And Connectors
System Board Jumper Settings
For information on resetting the password jumper to disable a password, see Disabling A Forgotten Password.
Table 4. System Board Jumper Settings
Jumper Setting Description
PWRD_EN
(default)
The password feature is enabled (pins 2–4).
The password feature is disabled (pins 4–6). iDRAC local
access is unlocked at the next AC power cycle.
NVRAM_CLR
(default)
The configuration settings are cleared at the next system
boot (pins 3–5).
The configuration settings are retained at system boot
(pins 1–3).
139
System Board Connectors
Figure 71. System Board Jumpers and Connectors
Item Connector Description
1 PWR_CONN/P1 Power connector
2 CTRL PNL Control panel interface connector
3 FRONT VGA Video connector
4 SLOT1 PCIE-G2-X4(CPH) PCIe card connector 1
5 SLOT2 PCIE-G2-X1(CPH) PCIe card connector 2
6 SLOT3 PCIE-G3-X16(CPU1) PCIe card connector 3
7 SLOT4 PCIE-G3-X4(CPU1) PCIe card connector 4
8 SLOT6 PCIE-G3-X4(CPU1) PCIe card connector 6
9 iDRAC_ENT iDRAC connector
10 ID_BTN System identification button
11 CMA_JACK System identification connector
12 USB4 top/USB5/USB6 BOT USB connector
140
Item Connector Description
13 USB1 top/USB2/USB3 BOT USB connector
14 NIC1 TOP/NIC2 BOT NIC connector
15 COM TOP/VGA BOT Serial connector/video connector
16 INTRUSION Chassis intrusion switch connector
17 12V_2/P2 Power connector
18 12V_1/P3 Power connector
19 A1, A2, A3, A4, A5, A6 Memory module sockets
20 CPU1 Processor socket
21 FAN2 External cooling fan connector
22 BP_CONN Backplane connector
23 BATTERY System battery connector
24 INT USB Internal USB connector
25 FAN1 Internal cooling fan connector
26 PDB_I2C/P6 Power distribution board connector
27 ODD2/TBU SATA_F connector for optical disk drive 2 or SATA
tape backup unit
28 ODD1/TBU SATA_E connector for optical disk drive 1 or, tape
backup unit in software RAID-configured systems
29 SATA_A SATA connector
30 JUMPER Jumper
31 IDSDM IDSDM connector
32 PERC card CONN HDD activity connector
Disabling A Forgotten Password
The system's software security features include a system password and a setup password. The password jumper
enables these password features or disables them and clears any password(s) currently in use.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2. Open the system.
3. Move the jumper on the system-board jumper from pins 2 and 4 to pins 4 and 6.
4. Close the system.
The existing passwords are not disabled (erased) until the system boots with the Jumper on pins 4 and 6. However,
before you assign a new system and/or setup password, you must move the jumper back to pins 2 and 4.
141
NOTE: If you assign a new system and/or setup password with the jumper on pins 4 and 6, the system disables
the new password(s) the next time it boots.
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
6. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
7. Open the system.
8. Move the jumper on the system-board jumper from pins 4 and 6 to pins 2 and 4.
9. Close the system.
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
11. Assign a new system and/or setup password.
142
8
Technical Specifications
Processor
Processor type • One Intel Xeon processor E5-2400 and E5-2400 v2
product family, or
• One Intel Xeon processor E5-1400 and E5-1400 v2
product family, or
• One Intel Pentium processor 1400 and 1400 v2
product family
Expansion Bus
Bus type PCI Express Generation 3 and 2
Expansion slots
(Slot 1) One full-height, half-length x4 PCIe Gen2 card slot
connected to Platform Controller Hub (PCH)
(Slot 2) One full-height, full-length x1 PCIe Gen2 card slot
connected to PCH
(Slot 3) One full-height, full-length x16 PCIe Gen3 card
slot connected to processor
(Slot 4) One full-height, full-length x4 PCIe Gen3 card slot
connected to processor
(Slot 5) Not applicable
(Slot 6) One full-height, half-length x4 PCIe Gen3 card slot
connected to processor
Memory
Architecture 800 MT/s, 1066 MT/s, 1333 MT/s, or 1600 MT/s DDR3
registered or unbuffered Error Correcting Code (ECC)
DIMMs
Support for advanced ECC or memory optimized
operation
Memory module sockets Six 240-pin
Memory module capacities
RDIMMs 2 GB (single-rank), 4 GB (single- and dual-rank), 8 GB
(single- and dual-rank), 16 GB (dual-rank), and 32 GB
(quad-rank)
143
Memory
UDIMMs 2 GB (single-rank) and 4 GB (single- and dual-rank)
Minimum RAM 2 GB
Maximum RAM
RDIMMs 192 GB
UDIMMs 24 GB
Drives
Hard drives
Four hard-drive systems Up to four 3.5 inch, internal, cabled SATA, nearline SAS,
or SAS hard drives.
Eight hard-drive systems Up to eight 3.5 inch, internal, hot-swappable SATA,
nearline SAS, SAS hard drives.
NOTE: 2.5 inch drives in 3.5 inch carriers are
supported for SAS, SATA SSD or SAS SSD drives.
Sixteen hard-drive systems Up to sixteen 2.5 inch, internal, hot-swappable SATA,
nearline SAS, SAS , SAS SSD, or SATA SSD drives.
Optical drive Up to two optional SATA DVD-ROM drive or DVD+/-RW
drive.
NOTE: If your system is installed with a double-width
GPU card, the system supports only one 5.25 inch
removable media storage device.
Tape drive One optional 5.25 inch tape drive.
NOTE: If your system is installed with a double-width
GPU card, the system supports only one 5.25 inch
removable media storage device.
Connectors
Back
NIC Two 10/100/1000 Mbps
Serial 9-pin, DTE, 16550-compatible
USB Six 4-pin USB 2.0-compliant
Video 15-pin VGA
iDRAC 7 One iDRAC 7 port
SD vFlash One SD vFlash card slot
Front
USB Two 4-pin USB Host
144
Connectors
Video 15-pin VGA, for systems in rack mode only
Internal
USB One 4-pin, USB 2.0-compliant
Internal Dual SD Module Two optional flash memory card slots with the internal SD
module
NOTE: One card slot is dedicated for redundancy.
Video
Video type Integrated Matrox G200
Video memory 16 MB shared
Expanded Operating Temperature
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on
the LCD and in the System Event Log.
< 10% of annual operating hours 5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.
NOTE: Outside the standard operating temperature
(10 °C to 35 °C), the system can operate down to 5 °C
or up to 40 °C for a maximum of 10% of its annual
operating hours.
For temperatures between 35 °C and 40 °C, de-rate
maximum allowable dry bulb temperature by 1 °C per 175
m above 950 m (1 °F per 319 ft).
< 1% of annual operating hours –5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.
NOTE: Outside the standard operating temperature
(10 °C to 35 °C), the system can operate down to –5
°C or up to 45 °C for a maximum of 1% of its annual
operating hours.
For temperatures between 40 °C and 45 °C, de-rate
maximum allowable dry bulb temperature by 1 °C per 125
m above 950 m (1 °F per 228 ft).
Expanded Operating Temperature Restrictions • Both the internal cooling fan and the external cooling
fan must be installed.
• The operating temperature specified is for a
maximum altitude of 3048 m (10,000 ft).
• GPU is not supported.
• Non-redundant power supplies are not supported.
• Non Dell qualified peripheral cards and/or peripheral
cards greater than 25 W are not supported.
145
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Maximum Temperature Gradient (Operating and Storage) 20 °C/h (36 °F/h)
Storage Temperature Limits –40 °C to 65 °C (–40 °F to 149 °F)
Temperature (Continuous Operation)
Temperature Ranges (for altitude less than 950 m or 3117
ft)
10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on
the equipment.
Humidity Percentage Range 10% to 80% Relative Humidity with 26 °C (78.8 °F)
maximum dew point.
Relative Humidity
Storage 5% to 95% RH with 33 °C (91 °F) maximum dew point.
Atmosphere must be non-condensing at all times.
Maximum Vibration
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides
tested).
Maximum Shock
Operating One shock pulse in the positive z axis of 31 G for 2.6 ms
in all operational orientations.
Storage Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms.
Maximum Altitude
Operating 3048 m (10,000 ft).
Storage 12,000 m (39,370 ft).
Operating Altitude De-rating
Up to 35 °C (95 °F) Maximum temperature is reduced by 1 °C/300 m (1
°F/547 ft) above 950 m (3,117 ft).
35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1 °C/175 m (1
°F/319 ft) above 950 m (3,117 ft).
40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1 °C/125 m (1
°F/228 ft) above 950 m (3,117 ft).
Particulate Contamination
146
Environmental
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and
gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits
specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you
to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of
environmental conditions will be the responsibility of the customer.
Air Filtration
NOTE: Applies to data center environments only. Air
filtration requirements do not apply to IT equipment
designed to be used outside a data center, in
environments such as an office or factory floor.
Data center air filtration as defined by ISO Class 8 per
ISO 14644-1 with a 95% upper confidence limit.
NOTE: Air entering the data center must have
MERV11 or MERV13 filtration.
Conductive Dust
NOTE: Applies to data center and non-data center
environments.
Air must be free of conductive dust, zinc whiskers, or
other conductive particles.
Corrosive Dust
NOTE: Applies to data center and non-data center
environments.
• Air must be free of corrosive dust.
• Residual dust present in the air must have a
deliquescent point less than 60% relative humidity.
Gaseous Contamination
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Copper Coupon Corrosion Rate <300 Å/month per Class G1 as defined by ANSI/
ISA71.04-1985.
Silver Coupon Corrosion Rate <200 Å/month as defined by AHSRAE TC9.9.
147
148
9
System Messages
LCD Messages
NOTE: Applicable only if your system has an LCD display.
The LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For
information on the SEL and configuring system management settings, see the systems management software
documentation.
NOTE: If your system fails to boot, press the System ID button for at least 5 seconds until an error code is displayed
on the LCD. Record the code, then see System Error Messages.
Viewing LCD Messages
If a system error occurs, the LCD screen will turn amber. Press the Select button to view the list of errors or status
messages. Use the Left and Right buttons to highlight an error number, and press the Select button to view the error.
Removing LCD Messages
For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically
removed when that sensor returns to a normal state. For other faults, you must take action to remove the message from
the display:
• Clear the SEL — You can perform this task remotely, but you will lose the event history for the system.
• Power cycle — Turn off the system and disconnect it from the electrical outlet; wait approximately 10 seconds,
reconnect the power cable, and restart the system.
System Error Messages
System messages appear on the monitor to notify you of a possible problem with the system. These messages refer to
events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings,
see the systems management software documentation.
Some messages are also displayed in an abbreviated form on the system's LCD, if the system includes that feature.
NOTE: The LCD error messages listed here are displayed in the simple format. See Setup Menu to select the format
in which the messages are displayed.
NOTE: If you receive a system message not listed here, check the documentation of the application that was
running when the message was displayed or the operating system's documentation for an explanation of the
message and recommended action.
NOTE: In some messages, a particular system component is identified by name (“<name>”) component number
(“<number>”), or location (“bay”).
149
Error Code Message Information
AMP0302 Message The system board <
name
> current is greater than the upper warning
threshold.
Details System board <
name
> current is outside of the optimum range.
Action 1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
AMP0303 Message The system board <
name
> current is greater than the upper critical
threshold.
LCD Message System board <
name
> current is outside of range.
Details System board <
name
> current is outside of the optimum range.
Action 1. Review system power policy.
2. Check system logs for power related failures.
3. Review system configuration changes.
4. If the issue persists, see Getting Help.
ASR0000 Message The watchdog timer expired.
Details The operating system or an application failed to communicate within
the time-out period.
Action Check the operating system, application, hardware, and system event
log for exception events.
ASR0001 Message The watchdog timer reset the system.
Details The operating system or an application failed to communicate within
the time-out period. The system was reset.
Action Check the operating system, application, hardware, and system event
log for exception events.
ASR0002 Message The watchdog timer powered off the system.
Details The operating system or an application failed to communicate within
the time-out period. The system was shut down.
Action Check the operating system, application, hardware, and system event
log for exception events.
150
Error Code Message Information
ASR0003 Message The watchdog timer power cycled the system.
Details The operating system or an application failed to communicate within
the time-out period. The system was power-cycled.
Action Check the operating system, application, hardware, and system event
log for exception events.
BAT0002 Message The system board battery has failed.
LCD Message The system board battery has failed. Check battery.
Details The system board battery is either missing or bad.
Action See Getting Help.
BAT0017 Message The <
name
> battery has failed.
LCD Message The <
name
> battery has failed. Check battery.
Details The <
name
> battery is either missing, bad, or unable to charge due to
thermal issues.
Action Check system fans. If the problem persists, see Getting Help.
CPU0000 Message CPU <
number
> has an internal error (IERR).
LCD Message CPU <
number
> has an internal error (IERR).
Details System Event Log and Operating System Logs may indicate that the
exception is external to the processor.
Action Review System Event Log and Operating System Logs. If the issue
persists, see Getting Help.
CPU0001 Message CPU <
number
> has a thermal trip (over-temperature) event.
LCD Message CPU <
number
> has a thermal trip. Check CPU heat sink.
Details The processor temperature increased beyond the operational range.
Action Review the logs for fan failures. If no fan failures are detected, check
inlet temperature (if available) and reinstall processor heat sink. If the
problem persists, see Getting Help.
CPU0005 Message CPU <
number
> configuration is unsupported.
LCD Message CPU <
number
> configuration is unsupported. Check CPU or BIOS
revision.
Details System is unable to boot or may run in a degraded state.
151
Error Code Message Information
Action Review the technical specifications for supported processor types.
CPU0010 Message CPU <
number
> is throttled.
Details The CPU is throttled due to thermal or power conditions.
Action Review system logs for power or thermal exceptions.
CPU0023 Message CPU <
number
> is absent.
LCD Message CPU <
number
> is absent. Check CPU.
Action Verify processor installation. If present, re-seat the processor.
CPU0204 Message CPU <
number
> <
name
> voltage is outside of range.
LCD Message CPU <
number
> <
name
> voltage is outside of range. Re-seat CPU.
Details Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
Action 1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see Getting Help.
CPU0700 Message CPU <
number
> initialization error detected.
LCD Message CPU <
number
> initialization error detected. Power cycle system.
Details System BIOS was unable to initialize the processor.
Action 1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see Getting Help.
CPU0701 Message CPU <
number
> protocol error detected.
LCD Message CPU <
number
> protocol error detected. Power cycle system.
Details System event log and operating system logs may indicate that the
exception is external to the processor.
Action 1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
152
Error Code Message Information
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see Getting Help.
CPU0702 Message CPU bus parity error detected.
LCD Message CPU bus parity error detected. Power cycle system.
Details System event log and operating system logs may indicate that the
exception is external to the processor.
Action 1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see Getting Help.
CPU0703 Message CPU bus initialization error detected.
LCD Message CPU bus initialization error detected. Power cycle system.
Details System event log and operating system logs may indicate that the
exception is external to the processor.
Action 1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see Getting Help.
CPU0704 Message CPU <
number
> machine check error detected.
LCD Message CPU <
number
> machine check error detected. Power cycle system.
Details System event log and operating system logs may indicate that the
exception is external to the processor.
Action 1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
153
Error Code Message Information
5. If the issue persists, see Getting Help.
FAN0000 Message Fan <
number
> RPM is less than the lower warning threshold.
Details Fan operating speed is out of range.
Action Remove and reinstall the fan. If the issue persists, see Getting Help.
FAN0001 Message Fan <
number
> RPM is less than the lower critical threshold.
LCD Message Fan <
number
> RPM is outside of range. Check fan.
Details Fan operating speed is out of range.
Action Remove and reinstall the fan. If the issue persists, see Getting Help.
FAN1201 Message Fan redundancy is lost.
LCD Message Fan redundancy is lost. Check fans.
Details Fan has failed.
Action Remove and reinstall failed fans or install additional fans.
HWC1001 Message The <
name
> is absent.
LCD Message The <
name
> is absent. Check hardware.
Details The absent device may be necessary for proper operation. System
functionality may be degraded.
Action Reinstall or reconnect the hardware.
HWC2003 Message The storage <
name
> cable is not connected, or is improperly
connected.
LCD Message Storage <
name
> cable or interconnect failure. Check connection.
Details The cable may be necessary for proper operation. System
functionality may be degraded.
Action Check if the cable is present, then reinstall or reconnect.
HWC2005 Message The system board <
name
> cable is not connected, or is improperly
connected.
LCD Message System board <
name
> cable connection failure. Check connection.
Details The cable may be necessary for proper operation. System
functionality may be degraded.
154
Error Code Message Information
Action Check if the cable is present, then reinstall or reconnect.
MEM0000 Message Persistent correctable memory errors detected on a memory device
at location(s) <
location
>.
Details This is an early indicator of a possible future uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help .
MEM0001 Message Multi-bit memory errors detected on a memory device at location(s)
<
location
>.
LCD Message Multi-bit memory error on <
location
>. Re-seat memory.
Details The memory module has encountered an uncorrectable error. System
performance may be degraded. The operating system and/or
applications may fail as a result.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0007 Message Unsupported memory configuration; check memory device at location
<
location
>.
LCD Message Unsupported memory configuration. Check memory <
location
>.
Details The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.
Action Check the memory configuration. Re-seat the memory modules. If the
issue persists, see Getting Help.
MEM0701 Message Correctable memory error rate exceeded for <
location
>.
Details The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM0702 Message Correctable memory error rate exceeded for <
location
>.
LCD Message Correctable memory error rate exceeded for <
location
>. Re-seat
memory.
Details The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM1205 Message Memory mirror redundancy is lost. Check memory device at
location(s) <
location
>.
155
Error Code Message Information
LCD Message Memory mirror lost on <
location
>. Power cycle system.
Details The memory may not be seated correctly, misconfigured, or has
failed.
Action Check the memory configuration. Re-seat the memory modules. If the
issue persists, see Getting Help.
MEM1208 Message Memory spare redundancy is lost. Check memory device at location
<
location
>.
LCD Message Memory spare lost on <
location
>. Power cycle system.
Details Memory sparing is no longer available.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
MEM8000 Message Correctable memory error logging disabled for a memory device at
location <
location
>.
LCD Message SBE log disabled on <
location
>. Re-seat memory.
Details Errors are being corrected but no longer logged.
Action Review system logs for memory exceptions. Reinstall memory at
location <
location
>.
PCI1302 Message A bus time-out was detected on a component at bus <
bus
>
device<
device
> function <
func
>.
Details System performance may be degraded. The device has failed to
respond to a transaction.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1304 Message An I/O channel check error was detected.
LCD Message I/O channel check error detected. Power cycle system.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1308 Message A PCI parity error was detected on a component at bus
<
bus
>device<
device
>function <
func
>.
LCD Message PCI parity error on bus <
bus
> device <
device
> function <
func
>.
Power cycle system.
Details System performance may be degraded, PCI device may fail to
operate, or system may fail to operate.
156
Error Code Message Information
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1320 Message A bus fatal error was detected on a component at bus
<
bus
>device<
device
>function <
func
>.
LCD Message Bus fatal error on bus <
bus
> device <
device
> function <
func
>. Power
cycle system.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1342 Message A bus time-out was detected on a component at slot <
number
>.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1348 Message A PCI parity error was detected on a component at slot <
number
>.
LCD Message PCI parity error on slot <
number
>. Re-seat PCI card.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1360 Message A bus fatal error was detected on a component at slot <
number
>.
LCD Message Bus fatal error on slot <
number
>. Re-seat PCI card.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PDR0001 Message Fault detected on drive <
number
>.
LCD Message Fault detected on drive <
number
>. Check drive.
Details The controller detected a failure on the disk and has taken the disk
offline.
Action Remove and re-seat the failed disk. If the issue persists, see Getting
Help.
PDR1016 Message Drive <
number
> is removed from disk drive bay <
bay
>.
157
Error Code Message Information
LCD Message Drive <
number
> removed from disk drive bay <
bay
>. Check drive.
Details The controller detected that the drive was removed.
Action Verify drive installation. Re-seat the failed drive. If the issue persists,
see Getting Help.
PST0128 Message No memory is detected.
LCD Message No memory is detected. Inspect memory devices.
Details System BIOS was unable to detect memory in the system.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
PST0129 Message Memory is detected, but is not configurable.
LCD Message Memory is detected, but is not configurable. Check memory devices.
Details System BIOS detected memory, but was unable to configure the
memory for system operation.
Action Compare system memory installation to supported system memory
configurations.
PSU0001 Message Power supply <
number
> failed.
LCD Message PSU <
number
> failed. Check PSU.
Action Remove and reinstall the power supply. If the issue persists, see
Getting Help.
PSU0002 Message A predictive failure detected on power supply <
number
>.
LCD Message Predictive failure on PSU <
number
>. Check PSU.
Details System performance and power redundancy may be degraded or
lost.
Action Remove and reinstall the power supply at the next service window. If
the issue persists, see Getting Help.
PSU0003 Message The power input for power supply <
number
> is lost.
LCD Message Power input for PSU <
number
> is lost. Check PSU cables.
Details The power supply is installed correctly but an input source is not
connected or is not functional.
Action Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.
158
Error Code Message Information
PSU0006 Message Power supply <
number
> type mismatch.
LCD Message Power supply <
number
> is incorrectly configured. Check PSU.
Details Power supplies should be of the same input type and power rating.
Action Install matched power supplies and review proper configuration in
this manual.
PSU0016 Message Power supply <
number
> is absent.
LCD Message PSU <
number
> is absent. Check PSU.
Details The power supply has been removed or has failed.
Action 1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see Getting Help.
PSU0031 Message Cannot communicate with power supply <
number
>.
LCD Message Cannot communicate with PSU <
number
>. Re-seat PSU.
Details The power supply may operate, however power supply monitoring is
degraded. System performance may be degraded.
Action Remove and reinstall the power supply. If the issue persists, see
Getting Help.
PSU0032 Message The temperature for power supply <
number
> is in a warning range.
Details System performance may be degraded.
Action Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
PSU0033 Message The temperature for power supply <
number
> is outside of the
allowable range.
LCD Message PSU <
number
> temperature outside of range. Check PSU.
Details System performance may be degraded.
Action Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
159
Error Code Message Information
PSU0034 Message An under voltage fault detected on power supply <
number
>.
LCD Message An under voltage fault detected on PSU <
number
>. Check power
source.
Details This failure may be the result of an electrical issue with cables or
subsystem components in the system.
Action 1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see Getting Help.
PSU0035 Message An over voltage fault detected on power supply <
number
>.
LCD Message Over voltage fault on PSU <
number
>. Check PSU.
Action Check input power or reinstall the power supply. If the issue persists,
see Getting Help.
PSU0036 Message An over current fault detected on power supply <
number
>.
LCD Message An over current fault detected on PSU <
number
>. Check PSU.
Details This failure may be the result of an electrical issue with cables or
subsystem components in the system.
Action 1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see Getting Help.
PSU0037 Message Fan failure detected on power supply <
number
>.
LCD Message Fan failure detected on PSU <
number
>. Check PSU.
Action Check for fan blockage. If the problem persists, see Getting Help.
PSU0076 Message A power supply wattage mismatch is detected; power supply
<
number
> is rated for <
value
> watts.
LCD Message PSU wattage mismatch; PSU <
number
> = <
value
>watts
Details Power supplies should be of the same input type and power rating.
Action Install matched power supplies and review this manual for proper
configuration.
160
Error Code Message Information
PSU1201 Message Power supply redundancy is lost.
Details The power supply tries to operate in a degraded state. System
Performance and power redundancy may be degraded or lost.
Action Check input power. Reinstall the power supply. If the issue persists,
see Getting Help.
PSU1204 Message The power supplies are not redundant. Insufficient resources to
maintain normal operations.
LCD Message PSU redundancy degraded. Check PSU cables.
Details The current power operational mode is non-redundant because of a
power supply exception, a power supply inventory change, or a
system power inventory change.
Action Check the event log for power supply failures. Review system
configuration and power consumption.
PWR1004 Message The system performance degraded because power capacity has
changed.
Details The system may power down or operate in a performance degraded
state.
Action Check the event log for power supply failures. Review system
configuration and power consumption and upgrade or install power
supplies accordingly.
PWR1005 Message The system performance degraded because the user-defined power
capacity has changed.
Details The user-defined power settings have affected system operation.
Action If unintended, review system configuration changes and power
policy.
PWR1006 Message The system halted because system power exceeds capacity.
LCD Message System power demand exceeds capacity. System halted.
Details The system halted because system power exceeds capacity.
Action Review system configuration, upgrade power supplies or reduce
system power consumption.
RFM1008 Message Failure detected on Removable Flash Media <
name
>.
LCD Message Removable Flash Media <
name
> failed. Check SD Card.
161
Error Code Message Information
Details An error was reported during a SD card read or write.
Action Reseat the flash media. If the problem persists, see Getting Help.
RFM1014 Message Removable Flash Media <
name
> is write protected.
LCD Message Removable Flash Media <
name
> is write protected. Check SD Card.
Details The card is write-protected by the physical latch on the SD card. A
write-protected card cannot be used.
Action If unintended, remove the media and disable write protection.
RFM1201 Message Internal Dual SD Module redundancy is lost.
LCD Message Internal Dual SD Module redundancy is lost. Check SD Card.
Details Either one or both the SD cards are not functioning properly.
Action See Getting Help.
RFM2001 Message Internal Dual SD Module <
name
> is absent.
LCD Message Internal Dual SD Module <
name
> is absent. Check SD Card.
Details The SD card module is not detected or not installed.
Action If unintended, reinstall the SD module.
RFM2002 Message Internal Dual SD Module <
name
> is offline.
Details The SD card module is installed but may be improperly installed or
configured incorrectly.
Action Reinstall the SD module.
RFM2004 Message Failure detected on Internal Dual SD Module <
name
>.
LCD Message Internal Dual SD Module <
name
> failed. Check SD Card.
Details The SD card module is installed but improperly configured or failed to
initialize.
Action Reinstall the SD module and remove and reinstall SD cards.
RFM2006 Message Internal Dual SD Module <
name
> is write protected.
Details The module is write-protected. Changes may not be written to the
media.
Action If unintended, remove the media and disable write protection.
162
Error Code Message Information
SEC0031 Message The chassis is open while the power is on.
LCD Message Intrusion detected. Check chassis cover.
Details The chassis is open. System performance may be degraded, and
security may be compromised.
Action Close the chassis. Check system logs.
SEC0033 Message The chassis is open while the power is off.
LCD Message Intrusion detected. Check chassis cover.
Details The chassis was opened while the power was off. System security
may have been compromised.
Action Close the chassis and verify hardware inventory. Check system logs.
SEL0006 Message All event logging is disabled.
Details This message is displayed when all event logging has been disabled
by the user.
Action If unintended, re-enable logging.
SEL0008 Message Log is full.
Details When the event log is full, additional events are not written to the log.
Older events may be overwritten and lost. This message may also
appear if the user disabled event logging.
Action Backup and clear log.
SEL0012 Message Could not create or initialize the system event log.
Details If the system event log fails to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
Action Reboot the management controller or iDRAC. Cycle system input
power. If problem persists call support.
SEL1204 Message An unknown system hardware failure detected.
LCD Message Unknown system hardware failure.
Details If the system event log failed to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
163
Error Code Message Information
Action Re-configure system to the minimum supported configuration. If
issues persists, contact support.
TMP0118 Message The system inlet temperature is less than the lower warning
threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0119 Message The system inlet temperature is less than the lower critical threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0120 Message The system inlet temperature is greater than the upper warning
threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
TMP0121 Message The system inlet temperature is greater than the upper critical
threshold.
LCD Message System inlet <
name
> temperature is outside of range. Check Fans.
Details Ambient air temperature is too warm or one or more fans may have
failed.
Action Check the system operating environment and review event log for fan
failures.
VLT0204 Message The system board <
name
> voltage is outside of the allowable range.
LCD Message System board voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
164
Error Code Message Information
Action 1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
3. If the issue persists, see Getting Help.
Warning Messages
A warning message alerts you to a possible problem and prompts you to respond before the system continues a task.
For example, before you format a hard drive, a message warns you that you may lose all data on the hard drive. Warning
messages usually interrupt the task and require you to respond by typing y (yes) or n (no).
NOTE: Warning messages are generated by either the application or the operating system. For more information,
see the documentation that accompanied the operating system or application.
Diagnostic Messages
The system diagnostic utilities may issue messages if you run diagnostic tests on your system. See “Using System
Diagnostics” chapter for more information about system diagnostics.
Alert Messages
Systems management software generates alert messages for your system. Alert messages include information, status,
warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems
management software documentation.
165
166
10
Getting Help
Contacting Dell
NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice,
packing slip, bill, or Dell product catalog.
Dell provides several online and telephone-based support and service options. Availability varies by country and
product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer
service issues:
1. Visit dell.com/support
2. Select your support category.
3. Verify your country or region in the Choose a Country/Region drop-down menu at the top of page.
4. Select the appropriate service or support link based on your need.
167