-562
560
14
11
110
-482
480
8
6.5
70
6
580
500
38
12
5
48
60
20
20
PAA 642 /I(WH) 12NC/Fx: F100511 GTIN (EAN) code:
8050147005118
DIMENSION MEASURE
APPLIANCE
Product width 580 mm
Product depth 500 mm
Radius of product corner 6 mm
Product height (MAX protrusion from the worktop) 48 mm
Underneath the bearing area of the appliance 38 mm
Distance between cut out and top frontal projection 14 mm
Distance between cut out and top lateral projection 11 mm
Plateau thickness 12 mm
Gas outlet positioning Rear right
Gas outlet X positioning 31 mm
Gas outlet Y positioning 20 mm
Power cable With
product
Power cable positioning Rear right
CUT OUT
MIN front distance from cut-out to end worktop 0 mm
MIN rear distance from cut out to wall/furniture 70 mm
MIN lateral distance from cut out to wall/furniture 110 mm
MIN height from worktop to above furniture 400 mm
MIN cut out width 560 mm
MAX cut out width 562 mm
MIN cut out depth 480 mm
MAX cut out depth 482 mm
MIN cut out radius 6.5 mm
MAX cut out radius 8 mm
FLUSH INSTALLATION
Indicates whether a flush installation is possible. Default is "N" No
MIN Milling rabbet width 0 mm
MAX Milling rabbet width 0 mm
MIN Milling rabbet depth 0 mm
MAX Milling rabbet depth 0 mm
Milling rabbet thickness 0 mm
Radius milling rabbet 0 mm
Flush installation KIT (2) N/A
Indicates the minum worktop thickness with standard installation for gas 20 mm
Indicates the maximum worktop thickness with standard installation for gas 60 mm
Indicates the minum worktop thickness with flush installation for gas 0 mm
Indicates the maximum worktop thickness with flush installation for gas 0 mm
WITH OVEN
Indicates whether the cooktop can be installed above oven. Default is "Y" Yes
MIN worktop thickness with oven 0 mm
MAX worktop thickness with oven 0 mm
DIMENSION MEASURE
Indicates whether a protection tray against heat or contact is needed with oven. Default is "N" No
Indicates whether a ventilation opening in the back side of cabinet is needed or not with oven.
Default is "Y"
No
Indicates the position of the opening in the back side of the cabinet with oven N/A
MIN Width of rear opening required with oven 0 mm
MIN Depth of rear opening required with oven. 0 mm
MIN AREA of rear opening required with oven 0 cm²
MIN distance from cabinet to rear wall, with oven 0 mm
Indicates whether a ventilation opening in the top front side of cabinet is needed or not with
oven. Default is "N"
No
MIN Frontal gap required, with oven (2) 0 mm
MIN frontal opening area required with oven 0 cm²
WITH CABINET
MIN worktop thickness with cabinet 0 mm
MAX worktop thickness with cabinet 0 mm
Indicates whether a protection tray against heat or contact is needed. Default is "Y" Yes
MIN distance from bottom line of appliance to protection tray 20 mm
Indicates whether a ventilation opening in the tray is needed or not with cabinet No
Recess dimension X 0 mm
Recess dimension Y 0 mm
Positioning dimension X by axis 0 mm
Distance of the tray from the back panel/wall 0 mm
Indicates whether a divider is available N/A
Indicates whether a ventilation opening in the back side of cabinet is needed or not. Default is
"Y"
No
Indicates the position of the opening in the back side of the cabinet. N/A
MIN Width of rear opening of the cabinet 0 mm
MIN Depth of rear opening of the cabinet 0 mm
MIN AREA of rear opening of the cabinet 0 cm²
MIN distance from cabinet to rear wall 0 mm
Indicates whether a ventilation opening in the top front side of cabinet is needed or not. Default
is "N"
No
MIN Frontal gap of the cabinet 0 mm
MIN frontal opening area of the cabinet 0 cm²
INSTALLATION SPACE
Depth of immersion underneath the appliance 5 mm
Width protruding area below bottom box 80 mm
Depth protruding area below bottom box 72 mm
Protruding area: X positioning 10 mm
Protruding area: Y positioning 3 mm
ACCESSORIES FOR INSTALLATION
Gasket Separate
KIT
Clips Separate
DIMENSION MEASURE
KIT
Injector KIT Separate
KIT
Elbow KIT N/A
COOKTOP HOOD INSTALLATION ONLY FOR GAS
MIN distance from cooktop to above furniture 750 mm
MIN distance between cabinets above the cooktop 600 mm