Mounting instructions
9MX056 MDU-PWR
Starter Set/Extension Set
IP20 CL I
Page/Seite
2
3
9MX056 MDU-PWR Extension Set
c
4
Retrofit/Nachrüstung
b
9MX056 MDU-PWR Starter Set
New Installation/Neuinstallation
a
9MX056 MDU-PWR Starter Set
3
Trunking
Tragschiene
Electrical unit
Lichtträger
Reflector
Reflektor
2
10
max.
3,5 Nm
B
A
B
Coupling
piece
Kupplung
No Internal
coupling piece
Keine Innenkupplung
New Installation/Neuinstallation
a
9MX056 MDU-PWR Starter Set
2
1
1
4
Cable Clip
Kabel-Clip
Coupling piece
Kupplung
9MX056 CP
AUTO
Operation mode
Betriebszustand
5
Manual actuation
Manuelle Betätigung:
Position « I » : permanent control ON
Position « O » : permanent control OFF
Position « AUTO » : electric control by switch
3
max. 2,5 mm
2
CLICK
8
max.
4
L1
L3
N
L2
NN
LL
+
L1
L3
N
L2
NN
LL
+
L1
L3
N
L2
NN
LL
+
CLICK
2
AUTO
4
3
2
3
Retrofit/Nachrüstung
b
9MX056 MDU-PWR Starter Set
Trunking
Tragschiene
Electrical unit
Lichtträger
Reflector
Reflektor
2
10
max.
3,5 Nm
B
A
B
Coupling
piece
Kupplung
No Internal
coupling piece
Keine Innenkupplung
5
Cable Clip
Kabel-Clip
Coupling piece
Kupplung
9MX056 CP
1
Operation mode
Betriebszustand
1
Manual actuation
Manuelle Betätigung:
Position « I » : permanent control ON
Position « O » : permanent control OFF
Position « AUTO » : electric control by switch
** Electrical connection must be
adjusted on site by the installer.
Elektrischer Anschluss muss
bauseits vom Installateur ange-
passt werden.
5
L1
L3
N
L2
NN
LL
+
L1
L3
N
L2
NN
LL
+
L1
L3
N
L2
NN
LL
+
CLICK
4
max. 2,5 mm
2
CLICK
8
max.
**
6
3
Extension Set Mounting/Extension Set montage
Klemmenbelegung Kabelfarbe Funktion
Pin/core Colour wire Function
1White/Weiss +12 V supply/Anschluss
2Black/Schwarz GND
3Red/Rot -
4Green/Grün Light sensor/Lichtsensor
5Yellow/Gelb +12 V supply/Anschluss
6Blue/Blau +12 V supply/Anschluss
RJ-12 (6p/6c)
1
2
3
6
5
4
LRM8117
Cable clip
Kabel-Clip
9MX056 ECC
4
9MX056 MDU-PWR Extension Set
c
Starter Set
1
CLICK
2
CLICK
CLICK
Extension Set
RJ-12 cable to be ordered seperally
RJ-12-Kabel muss separat bestellt werden
AWG 26 RJ-12 (6p/6c)
1
2
3
6
5
4
1
2
3
6
5
4
Supply Voltage *
Supply Current
“Signal” Output
12 to 24 VDC
8mA LED off
10mA LED on
Normally open
< 50 mA
* I short circuit < 1A
RH
20-85%
kg
0.055 kg
+
–
+
–
3
Technical Data/
Technische Daten
5
Distance between movement detectors for optimal coverage
Abtand zwischen den Bewegungssensoren für optimalen Anwendungsbereich
Maximum cable length between the Starter Set and the Extension Sets: 70 m.
Maximale Leitungslänge zwischen dem Starterset und den Erweiterungssensoren: 70 m
Mains
Netzanschluss
RADIAL R280 MOD766 RADIAL R280 MOD766
LRM 8117 LRM 8117 LRM 8117 LRM 8117
1,75 x H 1 x H 1 x H 1 x H 1 x H
Starter Set Extension Set
H=
5-15 m
40°
+
–
–40°
0°
+40°
+
–
1
+
–
2
–40° +40°
1,75 x H
40°
+
–
+
–
+
–
Maximum permissible number of electrical units with
LineSense per Phase in case of contemporay switch on
electrical Units per Phase.
Maximale Anzahl Leuchten je Phase bei gleichzeitigem
Einschalten. 36 W
4MX800 4x***LED
2x 36 W
4MX800 1x***LED
58 W
2x 58 W
4MX400 ***LED
4MX850 ***LED
4MX800 2x***LED
28
12
12
28
20
10
28
Power #
Circuit breaker type B16
Leitungsschutzschalter Typ B16
28 W
2x 54 W
2x 28 W
80 W
35 W
2x 80 W
2x 35 W
49 W
2x 49 W
54 W
12
8
8
12
12
8
18
12
12
8
Power #
Recommendation for mounting height of 5 m and length 70 m light line: 1 Starter Set plus 7 Extension Sets
Empfehlung bei Montagehöhe 5 m und Lichtbandlänge 70 m: 1 Starter Set plus 7 Extension Sets
Recommendation for mounting height of 15 m and length 70 m light line: 1 Starter Set plus 2 Extension Sets
Empfehlung bei Montagehöhe 15 m und Lichtbandlänge 70 m: 1 Starter Set plus 2 Extension Sets
LRM8117 Installation instructions
Philips Technologie GmbH
Supply Center Leuchten
Rathenaustraße 2-6
31832 Springe
Germany
Telephone +49(0)5041 75 0
6
default
Werkseinstellung
eingeschaltet
4321
On
321
= 1 min.
= 5 min.
= 35 min.
4
+ =
+ =
= 10 min.
= 15 min.
= 30 min.
= 25 min.
= 20 min.
LED
1
1
ON MORS
234
+
–
Indication LED
LED Anzeige
Time delay
Zeitververzögerung
default
Werkseinstellung
LRM 8117
t
Lux
*
Ref -
Ref +
+
+
-
3
Ref + Ref -
2
Daylight functionality/Tageslichtfunktion
+
-
+
When used with little or no natural light, leave
the reference light level potentiometer at maximum
(fully clockwise).
Bei Anwendung ohne oder mit wenig Tageslicht,
muss das Potentiometer auf seinem Maximalwert
(im Uhrzeigersinn bis zum Anschlag gedreht)
belassen werden. Damit ist die Tageslichtfunktion
außer Betrieb.
Daylight
functionality
Im Uhrzeigersinn
bis zum Anschlag
gedreht
fully clockwise
= aus
= off
Tageslicht-
funktion –
+
+ =
+ =
+ =