Mounting instructions
Suspension distances with coupling piece
Abhängeabstände mit Außenkupplung
X = 0,1 -0,7 m
D ≤ ..... m
4,70 m5,00 m 4,60 m 4,20 m 4,20 m 3,80 m
Maxos TL5 (16 mm Ø)
IP20
Facetted reflectors and optics
Facettenreflektoren und Optiken
Aluminium reflectors and optics
Aluminiumreflektoren und Aluprofilraster
kg
max. 30
kg
max. 30
kg
max. 30
kg
max. 30
Coupling
piece
Kupplung
L
D
X
DD
X
CL I
Length trunking sections
Maße Tragschiene
* 49 W-Länge = 35 W-Länge
= 80 W-Länge
* 49 W-length = 35 W-length
= 80 W-length
** 54 W-Länge = 28 W-Länge
** 54 W-length = 28 W-length
49* 1
1479 = 1 x 1479 mm
2958 = 2 x 1479 mm
49* 2
49* 3
4437 = 3 x 1479 mm
54** 1
1179 = 1 x 1179 mm
3537 = 3 x 1179 mm
54** 3
L
(mm)
Type
54** 2
2358 = 2 x 1179 mm
Electrical unit
Lichtträger
Trunking
Tragschiene
Mirror optic
Spiegel-Optik
Top reflector
Kopfspiegel
Facetted
reflector
Facetten-
reflektor
Reflector
Reflektor
Aluprofil optic
Aluprofilraster
Ø 10,4 max.
H07VV (NYM)
Ø10,4
L1
L3
N
L2
NN
LL
+
L1
L3
N
L2
NN
LL
+
L1
L3
N
L2
NN
LL
+
CLICK
max. 2,5 mm
2
CLICK
8
max.
2
Trunking/Tragschiene
Fixation/
Fixierung
- Bei Fest-
stellzunge
Disconnect
Entriegeln
B
A
B
B
Coupling
piece
Kupplung
10
max.
3,5 Nm
A
Suspension bracket/Abhänger
D
3
Xitanium 17W 0.3-0.7A
24V TE/I 230V
Xitanium 17W 0.3-0.7A
24V I 230V
Xitanium 25W 0.3-1A
36V TD/I
Inom (A) 0,15 0,15 0,2
Imax (A) 21 21 16
Tref (us) 400 400 400
MCB Nr Drivers Max
B-10A 7 7 17
B-16A 12 12 28
C-10A 13 13 28
C-16A 22 22 47
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
3-length/3-längig
NN/ /DA/Neutral/NS
LL/+/DA/Phase/LS
L3
N
L1
L2
L2 L3
L1
Specific electical unit
Spezieller Lichtträger
NN/ /DA/Neutral/NS
LL/+/DA/Phase/LS
L3
N
L1
L2
Phase selection/Phasenwahl
Additional terminal
Zusatzklemme
Emergency circuit
Notstromkreis
Emergency circuit
Notstromkreis
L1 L2 L3
=
NN/ /DA/Neutral/NS
LL/+/DA/Phase/LS
L3
N
L1
L2
DALI DALI
DALI
HFR-TD LS
NS
LN
NN
+
-
HFR 1-10 V
Emergency Light
Notlicht
Specific electrical unit
Spezieller Lichtträger
4
1
4
6
5
2
2
3
3
3
2
CLICK
CLICK
B
A
4
Optic/Raster
5
Optic/Raster C
AB
IN
*A
*A - Clip (optional)
Aluminium reflectors and optics
Aluminiumreflektoren und Aluprofilraster
L2 L3
L1
1
CHECK
Note:
For special reflectors!
Hinweis:
Bei Sonderreflektoren!
6
=
Turn page!
Siehe Rückseite!
Trunking
Tragschiene
Electrical unit
Lichtträger
Reflector
Reflektor
Aluprofil optic
Aluprofilraster
Bracket
Federbügel
3
3
5
2
2
4
4
1
*B
*B
2
3
4
To p
reflector
Kopfspiegel
5
Optic/Raster
IN
CLICK
CLICK
*B - Reflector coupling piece
Reflektor Verbinder
L2 L3
L1
1
CHECK
Facetted reflectors and optics
Facettenreflektoren und Optiken
=
Turn page!
Siehe Rückseite!
Trunking
Tragschiene
Electrical unit
Lichtträger
Top reflector
Kopfspiegel
Facetted
reflector
Facetten-
reflektor
Mirror optic
Spiegel-Optik
Bracket
Bügel
5
Philips Technologie GmbH
Supply Center Leuchten
Rathenaustraße 2-6
31832 Springe
Germany
Telephone +49(0)5041 750
CHECK
A
Reflectors/Reflektoren
GEALUX-Trunking/Tragschiene
Hook/Federhaken
Hook/Federhaken
GEALUX MAXOS
CLICK
Suspension brackets/Abhänger
10
8
97
65
l
432
1
217 557 00
217 540 00
556 762 99
556 786 99
557 073 99
571 970 99
571 925 99
107 919 00
107 827 00
107 933 00
107 841 00
107 940 00
107 858 00
571 994 99
538 669 99
107 971 00
551 088 99
572 007 99
571 949 99
571 963 99
571 918 99
571 901 99
chain bracket, adjustable (35mm), silver
chain bracket, adjustable (35mm), white
chain bracket, silver
chain bracket, white
chain bracket, zinc
mounting bracket for perforated suspension strip, silver
mounting bracket for perforated suspension strip, white
mounting bracket with suspension tube l=1250 mm, silver
mounting bracket with suspension tube l=1250 mm, white
mounting bracket with suspension wire
l=1250mm, silver
mounting bracket with suspension wire
l=1250mm, white
mounting bracket with suspension wire
l=3000mm, silver
mounting bracket with suspension wire
l=3000mm, white
mounting bracket for suspension wire (2mm), silver
mounting bracket for suspension wire (2mm), white
suspension wire fixation set (2 sleeves, 2 clamps)
suspension wire diameter 2mm / per meter
profile bracket for visible T-profiles, silver
profile bracket for visible T-profiles, white
mounting bracket for ceiling fixation, silver
mounting bracket for ceiling fixation, white
mounting bracket for ceiling fixation
with standard coupler, white
Kettenabhänger, höhenverstellbar (35mm), silber
Kettenabhänger, höhenverstellbar (35mm), weiß
Kettenabhänger, silber
Kettenabhänger, weiß
Kettenabhänger, zink
für Lochbandeisenmontage, silber
für Lochbandeisenmontage, weiß
Rohrpendelabhänger, l =1250 mm, silber
Rohrpendelabhänger, l =1250 mm, weiß
Universalabhänger mit Stahlseil 2 mm und Kausche,
l=1250mm, silber
Universalabhänger mit Stahlseil 2 mm und Kausche,
l=1250mm, weiß
Universalabhänger mit Stahlseil 2 mm und Kausche,
l=3000mm, silber
Universalabhänger mit Stahlseil 2 mm und Kausche,
l=3000mm, weiß
Universalabhänger für Stahlseil 2 mm, silber
Universalabhänger für Stahlseil 2 mm, weiß
Stahlseilbefestigung (2 Kauschen, 2 Klemmen)
Stahlseil Durchmesser 2mm (Länge in m)
Abhänger für sichtbares T-Profil, silber
Abhänger für sichtbares T-Profil, weiß
Abhänger für direkte Deckenmontage, silber
Abhänger für direkte Deckenmontage, weiß
Abhänger für direkte Deckenmontage,
bei Außenkupplung, weiß
Description Beschreibung EOC
9MX056 CBA SI
9MX056 CBA WH
9MX056 CB SI
9MX056 CB WH
9MX056 CB ZC
9MX056 MB-PS SI
9MX056 MB-PS WH
9MX056 MB-ST-L1250 SI
9MX056 MB-ST-L1250 WH
9MX056 MB-SW-L1250 SI
9MX056 MB-SW-L1250 WH
9MX056 MB-SW-L3000 SI
9MX056 MB-SW-L3000 WH
9MX056 MB-SW SI
9MX056 MB-SW WH
9MX056 SWF SET
9MX056 SW2
9MX056 PB SI
9MX056 PB WH
9MX056 MB SI
9MX056 MB WH
9MX056 WS DAH 64
1
2
3
4
5
6
7
7
8
9
10
a
b
Pos.
Disassembly of hook/Demontage des Federhaken
Mounting of electrical unit/Montage des Lichtträgers
Asymmetrical reflectors
Asymmetrische Reflektoren B
6
Technical Data/
Technische Daten
Maxos TL5 (16 mm Ø)
Note:
The maximum permissible suspen-
sion distance for MAXOS light-
lines are based on a static stability
under load of 30 kg (300 N) per
fixation point.
The industrial standards/norms
have to be followed when in-
Maximum permissible number of electrical units with
HF-gears in case of contemporary switch-on
Circuit breaker B 16 A
Circuit breaker B 16 A
Suspension distances
Recommended suspension
distances = 3,5 meter, maximum
permissible suspension distance for
MAXOS light-lines see chart.
The deflection of the trunking does
not exceed 10 mm between two
fixation points, at a maximum load
of 30 kg with a safety factor of 5
per suspension point.
The maximum overhang at the end
of the light-line should not be more
Free radiating/bare
1-lamp
HF-gear
Type 2-lamp
With reflector HF-gear
With reflector and louver HF-gear
5,0
4,6
4,2
4,7
4,2
3,8
Criteria:
Maximum permissible number of electrical units per
conductor/wire
Un=106 %
max. currant 16 A
max. voltage loss ≤ 5%
Balanced currents on light-lines (L1, L2, L3)
Maximum permissible suspension distance in meter (L):
stalling MAXOS light-lines.
In case of significant fluctuations
in temperature length-expanding
must be taken into account, the
expansions coefficient is
0,012 mm/°K m.
Note: Calculation of loop resistance has to be provided by
the customer!
HF-gear-type
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-gear HF-performer
128 TL5
228 TL5
135 TL5
235 TL5
149 TL5
249 TL5
154 TL5
254 TL5
180 TL5
30
28
30
28
30
12
30
12
12
HF-gear HF-regulator/Dali
128 TL5
228 TL5
135 TL5
235 TL5
149 TL5
249 TL5
154 TL5
254 TL5
180 TL5
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
28
28
28
12
28
12
28
12
12
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
2 HF-P
128 TL5
228 TL5
135 TL5
235 TL5
149 TL5
249 TL5
154 TL5
254 TL5
180 TL5
180 TL5
128 TL5
228 TL5
135 TL5
235 TL5
149 TL5
249 TL5
154 TL5
HF-R
HF-R
HF-R
HF-R
HF-R
HF-R
HF-R
HF-gear-type
wiring
1,5 mm22,5 mm2
HF-gear-type
36
30
33
24
29
20
28
53
40
43
32
37
27
36
wiring
1,5 mm22,5 mm2
43
30
35
24
29
21
32
22
23
16
56
40
45
32
38
27
41
28
30
21
Befestigungsabstände
Empfohlene Befestigungsab-
stände = 3,50 Meter.
Maximal zulässige Befestigungsab-
stände für Maxos-Lichtbänder
siehe Tabelle.
Die Durchbiegung der Tragschiene
ist nicht größer als 10 mm zwischen
2 Befestigungspunkten, bei einer
max. zulässigen Belastbarkeit von
30 kg bei 5facher Sicherheit pro
Befestigungspunkt.
Hinweis:
Alle zulässigen Befestigungsabstän-
de beruhen auf einer statischen
Belastbarkeit von 30 kg (300N)
pro Aufhänger.
Bei der Montage ist die Vorschrift
VDE 0100 Teil 559 zu beachten.
Bei der Montage von Maxos-
Lichtbändern ist darauf zu achten,
dass in Abhängigkeit von größeren
Temperaturänderungen Längen-
ausdehnungen auftreten können,
die bei der Montage entsprechend
berücksichtigt werden müssen.
Der Ausdehnungskoeffizient be-
trägt: 0,012 mm/°Km.
Freistrahlend
1-lampig
EVG
Typ 2-lampig
Reflektor EVG
Reflektor mit Raster EVG
5,0
4,6
4,2
4,7
4,2
3,8
Maximaler Befestigungsabstand in Meter (L):
Maximale Anzahl der Leuchten mit EVG bei
gleichzeitigem Einschalten
Absicherung durch
Leitungsschutzschalter B 16 A
Meß- und
Berechnungskriterien:
Maximale Anzahl der Lichtträger pro Außenleiter in
MAXOS-Lichtbändern mit Lampen TL5 (16 mm Ø)
Un=106 %
max. Außenleiterstrom 16 A
max. Spannungsfall ≤ 5%
Symmetrische Belastung der Lichtbänder
Hinweis: Die Berechnung des Schleifenwiderstandes muss bau-
seits erfolgen!
EVG HF-Regulator/Dali
128 TL5
228 TL5
135 TL5
235 TL5
149 TL5
249 TL5
154 TL5
254 TL5
180 TL5
EVG Typ
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
EVG HF-Performer
128 TL5
228 TL5
135 TL5
235 TL5
149 TL5
249 TL5
154 TL5
254 TL5
180 TL5
30
28
30
28
30
12
30
12
12
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
HF-R/D
28
28
28
12
28
12
28
12
12
128 TL5
228 TL5
135 TL5
235 TL5
149 TL5
249 TL5
154 TL5
HF-R
HF-R
HF-R
HF-R
HF-R
HF-R
HF-R
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
HF-P
2 HF-P
128 TL5
228 TL5
135 TL5
235 TL5
149 TL5
249 TL5
154 TL5
254 TL5
180 TL5
EVG-Typ
43
30
35
24
29
21
32
22
23
16
56
40
45
32
38
27
41
28
30
21
Durchverdrahtung
1,5 mm22,5 mm2
EVG-Typ
36
30
33
24
29
20
28
53
40
43
32
37
27
36
Durchverdrahtung
1,5 mm22,5 mm2
180 TL5
than half a lamp length, the minimum
overhang must be 100 mm. These
values are valid for normal position
of use of the light-lines.
When mounted directly to the
ceiling or usage of internal
coupling piece
(9MX056 CPI),
use one suspension per length of
electrical unit.
Der max. Überhang am Licht-
bandende soll 1
/2 Lampenlänge
nicht überschreiten, der min.
Überhang muss 100 mm betragen.
Die Werte gelten für normale
Gebrauchslage der Lichtbänder.
Bei direkter Deckenmontage, bzw.
Verwendung der Innenkupplung
(9MX056 CPI), ist für jede Licht-
bandeinheit (Lampenlänge) ein
Abhänger vorzusehen.