Manual Revision: June 10, 2020
5 Port Unmanaged Industrial-Grade Switch 10/100/1000 Mbps + 2 Open SFP & DIN Input
Product Diagram (IES1G52UPDIN)
Front View
Side View
Component Function
1Power (PW) LED
Indicators
• Color - Green
• DIN P3 (top), Terminal P2 (middle), Terminal P1
(bottom)
• On - PW1/2/3 is connected
• O - PW1/2/3 is not connected
2RLY LED Indicator
• Color - Amber
• On - Alarm Relay short
• O - Alarm Relay open
3F5/6 Port LED
Indicators
• Color - Green
• F5 (top), F6 (bottom)
• On - SFP link/connection is detected
• O - SFP link/connection is not detected
• Flashing - SFP is active
910 11
4PoE Ports
• Connect any Network Device to provide an Ethernet
Connection to up to 4 Network Devices
• Provide a Power over Ethernet (PoE) Connection to 4
Devices
• Maximum PoE power budget is 30W per port up to a
total overall power budget of 126W
5SFP Slots F6 (Left) and
F5 (Right) • Supports 100/1000Base-X SFP Transceiver Modules
6DIP Switches • Enable SFP Slot F5 or T5 Network Port
7Non-PoE Port
• Provide an Ethernet Connection to one Network
Device
• Connect using a Fiber or Copper Network Cable
8PoE Port LED
Indicators
• Indicates the link and PoE Powered Device (PD) status
LNK(Green)
• On - Network connection detected
• O - Network connection not detected
PoE (Amber)
• On - PoE PD is detected
• O - PoE PD is not detected
9DIN Power Port • Connect a DIN Connector Terminated Power Supply
10 Terminal Block Power
Input Port
• Provides power to the PoE Ports
• Supported power input voltage range is 48-56V
11 Grounding Screw • Attach a Grounding Wire to protect Network
Equipment
Requirements
For the latest requirements, please visit www.startech.com/IES1G52UPDIN.
• DC Power Supply x (up to) 2
• (Optional) DIN Connector Terminated Power Supply x 1
• PoE Powered Device x (up to) 4
• RJ45 Terminated UTP/STP Cat 5e (or better) Network Cable x (up to) 5
• MSA-Compliant 100/1000Base-X SFP Transceiver Module x (up to) 2
• Fiber Cable x (up to) 2
• Earth Ground Connection x 1
4
1
5 6
32
7 8
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modications not expressly approved by StarTech.com could void the user’s authority to operate the equipment.
Industry Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du Canada.
CAN ICES-3 (A)/NMB-3(A)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.
Use of Trademarks, Registered Trademarks, and other Protected Names and Symbols
This manual may make reference to trademarks, registered trademarks, and other protected names and/or symbols of third-
party companies not related in any way to StarTech.com. Where they occur these references are for illustrative purposes only
and do not represent an endorsement of a product or service by StarTech.com, or an endorsement of the product(s) to which
this manual applies by the third-party company in question. StarTech.com hereby acknowledges that all trademarks, registered
trademarks, service marks, and other protected names and/or symbols contained in this manual and related documents are the
property of their respective holders.
PHILLIPS® is a registered trademark of Phillips Screw Company in the United States or other countries.
Warranty Information
This product is backed by a two-year warranty.
For further information on product warranty terms and conditions, please refer to www.startech.com/warranty.
Limitation of Liability
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their ocers, directors, employees or
agents) for any damages (whether direct or indirect, special, punitive, incidental, consequential, or otherwise), loss of prots,
loss of business, or any pecuniary loss, arising out of or related to the use of the product exceed the actual price paid for the
product. Some states do not allow the exclusion or limitation of incidental or consequential damages. If such laws apply, the
limitations or exclusions contained in this statement may not apply to you.
Safety Measures
• If product has an exposed circuit board, do not touch the product under power.
Mesures de sécurité
• Si l’un des circuits imprimés du produit est visible, ne pas touchez le produit lorsqu’il est sous tension.
安全対策
• 製品に露出した状態の回路基盤が含まれる場合、電源が入っている状態で製品に触らないでください。
Misure di sicurezza
• Se il prodotto ha un circuito stampato visibile, non toccare il prodotto quando è acceso.
Säkerhetsåtgärder
• Rör aldrig vid enheter med oskyddade kretskort när strömmen är påslagen.
FR: startech.com/fr
DE: startech.com/de
ES: startech.com/es
NL: startech.com/nl
IT: startech.com/it
JP: startech.com/jp
StarTech.com Ltd.
45 Artisans Cres
London, Ontario
N5V 5E9
Canada
StarTech.com Ltd.
Unit B, Pinnacle 15
Gowerton Rd,
Brackmills
Northampton
NN4 7BW
United Kingdom
StarTech.com LLP
2500 Creekside
Parkwy
Lockbourne, Ohio
43137
U.S.A.
• Grounding Wire x 1
• (Optional - for power) Flat Head Screwdriver x 1
• (Optional - for mounting) #2 Phillips Head Screwdriver x 1
• (Optional - for mounting) Screws for Wall Mounting x 2
Installation
Grounding the Switch
Connect a Grounding Wire to the Grounding Point on the Switch and to the Earth
Ground Connection.
Connect the Redundant Power Sources
Terminal Block
Connecting and installing the Terminal Block must be completed by a licensed
Electrician.
Notes: Make sure that you turn o the power source before connecting the power wire
to the Terminal Block.
Do not exceed the recommend voltage as it may result in personal or product damage.
This unit includes an additional 24V@1A Relay Circuit. When two Terminal Power
Sources are connected the Relay stays in Open Mode. If only one Power Source is
connects the Relay switches to Short Mode.
1. Connect the Power Wires from a DC Power Source (48 - 56V DC) or the provided
Barrel Power Connector Adapter to the Terminal Block Connectors on the Switch.
The terminals are marked on the exterior of the Switch (connect the Positive Wire to
V+ and the Negative Wire to V-).
• Secure the Wires by tightening the Screws in the Terminal Block with a Flat
Head Screwdriver
2. (Optional) Repeat step 1 to add a redundant Power Source.
DIN Power
Connect a DIN Connector Terminated Power Supply to an available Power Source
and to the DIN Power Port on the Switch.
Power Pinout Diagram
Select the Default Function and Speed using the DIP Switches
Toggle the DIP Switches up and/or down to select the SFP Slot F5 (Right) or T5
Network Port and the Network Speed.
Note: If DIP 1 is set to T5 then DIP 2 must be set to 1000M.