Manual Revision: May 22, 2020
Product Diagram (IMC1GSFP30W)
Component Function
1DIP Switches
DIP Switch Position Function
DIP 1 (Left Side)
Up 100 Mbps
installations
Down 1000 Mbps
installations
DIP 2 (Right Side)
Up
Link Fault
Pass Through
enabled
Down
Link Fault
Pass Through
disabled
(default
setting)
2Power Input
Port
• Connect a Power Source
• DC power range is from 48V to 56V
Note: Ensure the input voltage is always within this range.
Industrial RJ45 to Open SFP Mini PoE Media Converter - 1000 Mbps (1G) - 30W
3LED
Indicators
LED Type Status Indication
PWR On Power detected
O Power not detected
LK/Act
On SFP detected
Flashing Fiber data is transmitting
and receiving
4RJ45 Port
• Connect a UTP/STP Cat 5e (or higher) Network Cable
LED
Type Status Indication
LNK
On Network connection is detected
Flashing Network data is transmitting and
receiving
POE On
Power Source Equipment (PSE) is
activated and Powered Device (PD) is
detected
Flashing PD not detected
5SFP Slot • Insert a 100/1000Base-X SFP Transceiver Module
Requirements
For the latest requirements, please visit www.startech.com/IMC1GSFP30W.
• Network Equipment (e.g. Router, Network Switch) x 1
• MSA-Compliant 100/1000Base-X SFP Transceiver Module x 1
• RJ45 Terminated UTP/STP Cat 5e (or better) Network Cable x 1
• Terminated Fiber Optic Cable (dependent on the chosen SFP Module) x 1
• Industrial DC Power Supply Unit or Universal Power Adapter with Type N
(OD: 5.5 mm, ID: 2.5 mm) Barrel Connector x 1
• Flat Head Screwdriver x 1
• (Optional - for mounting) Phillips Head Screwdriver x 1
• (Optional - for mounting) Screws x 2
Installation
Connecting the Media Converter
1. Insert an MSA-Compliant SFP Transceiver Module (sold separately) into the SFP
Slot on the Media Converter.
5
1
4
2
3
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modications not expressly approved by StarTech.com could void the user’s authority to operate the equipment.
Industry Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du Canada.
CAN ICES-3 (A)/NMB-3(A)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two
conditions:
(1) This device may not cause interference, and (2) This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.
Use of Trademarks, Registered Trademarks, and other Protected Names and Symbols
This manual may make reference to trademarks, registered trademarks, and other protected names and/or symbols of third-
party companies not related in any way to StarTech.com. Where they occur these references are for illustrative purposes only
and do not represent an endorsement of a product or service by StarTech.com, or an endorsement of the product(s) to which
this manual applies by the third-party company in question. StarTech.com hereby acknowledges that all trademarks, registered
trademarks, service marks, and other protected names and/or symbols contained in this manual and related documents are the
property of their respective holders.
PHILLIPS® is a registered trademark of Phillips Screw Company in the United States or other countries.
Warranty Information
This product is backed by a two-year warranty.
For further information on product warranty terms and conditions, please refer to www.startech.com/warranty.
Limitation of Liability
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their ocers, directors, employees or
agents) for any damages (whether direct or indirect, special, punitive, incidental, consequential, or otherwise), loss of prots,
loss of business, or any pecuniary loss, arising out of or related to the use of the product exceed the actual price paid for the
product. Some states do not allow the exclusion or limitation of incidental or consequential damages. If such laws apply, the
limitations or exclusions contained in this statement may not apply to you.
Safety Measures
• If product has an exposed circuit board, do not touch the product under power.
Mesures de sécurité
• Si l’un des circuits imprimés du produit est visible, ne pas touchez le produit lorsqu’il est sous tension.
安全対策
• 製品に露出した状態の回路基盤が含まれる場合、電源が入っている状態で製品に触らないでください。
Misure di sicurezza
• Se il prodotto ha un circuito stampato visibile, non toccare il prodotto quando è acceso.
Säkerhetsåtgärder
• Rör aldrig vid enheter med oskyddade kretskort när strömmen är påslagen.
FR: startech.com/fr
DE: startech.com/de
ES: startech.com/es
NL: startech.com/nl
IT: startech.com/it
JP: startech.com/jp
StarTech.com Ltd.
45 Artisans Cres
London, Ontario
N5V 5E9
Canada
StarTech.com Ltd.
Unit B, Pinnacle 15
Gowerton Rd,
Brackmills
Northampton
NN4 7BW
United Kingdom
StarTech.com LLP
2500 Creekside
Parkwy
Lockbourne, Ohio
43137
U.S.A.
Power Adapter to the Terminal Block to Barrel Power Connector Adapter.
Mounting the Media Converter
Wall Mounting
1. Align the holes in the Wall Mount Brackets with the holes in the back of the Media
Converter.
2. Insert two Phillips Head Screws through the Wall Mount Brackets and into the
Media Converter.
3. Tighten the Phillips Head Screws using a Phillips Head Screwdriver (sold
separately).
Note: Be careful not to over-tighten the Screws.
4. Insert two Screws (sold separately) through the Wall Mount Brackets and into the
Mounting Surface.
5. Tighten the Screws using the appropriate Screwdriver.
DIN Rail Mounting
1. Align the holes in the DIN Rail Bracket with the holes in the back of the Media
Converter.
2. Insert three Phillips Head Screws through the DIN Rail Bracket and into the Media
Converter.
3. Tighten the Phillips Head Screws using a Phillips Head Screwdriver.
Note: Be careful not to over-tighten the Screws.
4. Hang the top of the DIN Rail Bracket (the section with the two metal clips) onto a
Top Hat style DIN Rail.
5. Press the DIN Rail Bracket down and forward to lock the bottom section onto the
DIN Rail.
2. Remove the Dust Cover from the SFP Module.
3. Connect a Fiber Optic Cable (sold separately) to the Fiber Optic Port on the SFP
Module and to the Fiber-Network Device.
4. Connect a Network Cable (sold separately) to the RJ45 Port on the Media
Converter and to the Network Equipment.
Powering the Media Converter
Connecting and installing the 3-pin Terminal Block must be completed by a licensed
Electrician.
Notes: Make sure that you turn o the power source before connecting the power wire
to the Terminal Block.
Do Not exceed the recommend power source voltage as it may result in personal or
product damage.
Connect the Industrial DC Power Supply Unit (sold separately) to the Terminal Block.
• Connect the Positive Wire to V+
• Connect the Negative Wire to V-
• Connect the Neutral Wire to Ground
• Secure the Wires by tightening the Screws in the Terminal Block with a Flat Head
Screwdriver
--or--
Connect a Type N (OD: 5.5 mm, ID: 2.5 mm) Barrel Connector from a Universal