Tripp Lite OMNIVSX650A User Manual
Displayed below is the user manual for OMNIVSX650A by Tripp Lite which is a product in the Uninterruptible Power Supplies (UPSs) category. This manual has pages.
Related Manuals
1
UPS Systems
Model:
OMNIVSX650A
(Series Number: AG-04F0)
Important Safety Instructions ................. 2
Quick Installation ...................................4
Basic Operation .....................................5
UPS On/Off ..........................................5
LED Indicators .....................................5
Features ................................................6
UPS Features ......................................6
Battery Replacement ............................7
Storage and Service ..............................7
Regulatory Compliance ..........................8
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2020 Tripp Lite. All rights reserved.
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of this
product. Failure to heed these warnings may affect the warranty.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight.
• Operating Temperature: 0°C to 40°C
• Storage Temperature: -15°C to 45°C
• Humidity: 0% to 90% R.H.
• Operating Altitude: 0 m to 2,000 m
• Storage Altitude: 0 m to 3,000 m
• Pollution: PD2
• Overvoltage Category: II for normal mode, I for stored energy mode
• Leave adequate space around all sides of the UPS for proper ventilation.
• Only set the UPS upright on a sturdy flat surface. Do not block fans or ventilation holes, as this will seriously inhibit the unit's internal cooling
and cause product damage not covered under warranty.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.
• Do not modify the UPS plug, and do not use an adapter that would eliminate the UPS ground connection.
• Do not use extension cords to connect the UPS to an AC outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.
• The mains socket outlet that supplies the UPS should be easily accessible and located near the UPS.
• For use on a TN power distribution system of input power supply. The UPS stored energy output device provides a TN power system.
Equipment Connection Warnings
Short Circuit backup protection and overcurrent protection is provided by the building installation.
To reduce the risk of fire, connect only to a circuit provided branch circuit overcurrent protection. The plug on the power
supply cord is intended to serve as the disconnect device. Be sure the socket-outlet is installed near the equipment and
is made easily accessible.
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life
support equipment or to significantly affect its safety or effectiveness is not recommended.
• Do not connect surge protectors or extension cords to the output of your UPS. This might damage the UPS and may affect the surge
protector and UPS warranties.
• Connect the UPS to an outlet that is adequately protected against excess currents, short circuits and earth faults as part of the building
installation.
Model Number
Agency Series
Number
Dimensions
(H x W x D) Weight AC Fuse/Breaker
Output Short-
Circuit Current
OMNIVSX650A AG-04F0 142 x 101 x 300 mm 4.8 kg Fuse: T5AL, 250VAC Approx. 66.2A Peak
Important Safety Instructions
3
Important Safety Instructions
Battery Warnings
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. There are no user-
serviceable parts inside the UPS. Do not open the UPS except to perform battery replacement. Do not open or mutilate batteries. Do not
short or bridge the battery terminals with any object. Do not dispose of batteries in a fire, the batteries may explode. Released electrolyte is
harmful to the skin and eyes and may be toxic. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated
handles. Battery replacement should be performed only by authorised service personnel using the same number and type of batteries
(sealed lead acid). The batteries are recyclable. Refer to your local codes for disposal requirements or visit www.rbrc.com for recycling
information. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at
tripplite.com/products/battery-finder to locate the specific replacement battery for your UPS.
CAUTION: A battery can present a risk of electrical shock and high short-circuit current. Contact with any part of a
grounded battery can result in electrical shock. The following precautions should be observed when working on batteries:
• Remove watches, rings or other metal objects.
• Use tools with insulated handles.
• Wear rubber gloves and boots.
• Do not lay tools or metal parts on top of batteries.
• Disconnect charging source and load prior to installing or maintaining the battery.
• Remove battery grounds during installation and maintenance to reduce likelihood of shock.
• Remove the connection from ground if any part of the battery is determined to be grounded.
• Unplug the UPS from the AC mains receptacle. Disconnect all cables, including the equipment plugged into the UPS.
• Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and required precautions.
• When replacing batteries, replace with the same type and number of batteries or battery packs.
• CAUTION: Do not dispose of batteries in a fire. The batteries may explode.
• CAUTION: Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
UPS and Battery Recycling
Please recycle Tripp Lite Products. The batteries used in Tripp Lite products are sealed lead acid batteries. These batteries are highly
recyclable. Please refer to local codes for disposal requirements.
Call Tripp Lite for recycling info at +1.773.869.1234.
Go to the Tripp Lite Website for up-to-date information on recycling the batteries or any Tripp Lite product.
Please follow this link: tripplite.com/support/recycling-program/
4
STEP 1: Plug the UPS into
a properly grounded outlet.
After plugging the UPS into a wall outlet, press the power button to turn on the UPS
(See Basic Operation).
Note: The UPS will not turn on automatically in the presence of live utility power.
STEP 2: Plug your equipment into the UPS.
Outlets marked BATTERY & SURGE offer UPS battery backup support during power
failures. Connect your vital computer equipment into these outlets.
Your UPS is designed to support electronic equipment only. You will overload the UPS if
the total volt-amp (VA) ratings for all the equipment connected to the BATTERY/SURGE
PROTECTED outlets exceed the UPS output capacity. To find your equipment’s VA ratings,
look on their nameplates. If the equipment is listed in amps (A), multiply the number
of amps by 230 to determine VA. For example: 1A × 230 = 230VA. If you suspect
you have overloaded the outlets, check Load Meter screens (see Display UPS/Power
Conditions in Basic Operation).
If the on-line AC power icon does not illuminate when the UPS is turned ON, try the
following:
1. Make sure that the UPS is plugged into a live AC outlet.
2. Press the power button to turn on the UPS. A beep should sound when the UPS
starts.
3. If the UPS still does not start, contact Tripp Lite Tech Support for assistance.
Quick Installation
5
Basic Operation
UPS ON/OFF
• Plug the UPS into a live, grounded outlet.
The green LED will illuminate, the battery charger will engage as necessary and the SURGE PROTECTED outlets will begin passing power.
• Plug equipment into the UPS: You will overload the UPS if the total volt-amp (VA) ratings for all the equipment connected to the BATTERY/
SURGE PROTECTED outlets exceed the UPS output capacity. To find your equipment’s VA ratings, look on their nameplates. If the equipment
is listed in amps (A), multiply the number of amps by 230 to determine VA. For example: 1A × 230 = 230VA.
• Turn the UPS on: Press the power button . The UPS alarm will beep for 2 seconds. The BATTERY/SURGE PROTECTED outlets will begin
passing AC line power. The UPS will automatically recharge internal batteries as needed. Once turned on, your UPS is ready to protect
connected equipment from blackouts, brownouts, overvoltages and transient surges.
• Turn the UPS off: Press the power button .
LED Indicators
Description Fault LED (Red) Battery LED (Amber) Online LED (Green) Alarm
Line Mode Off Off On Off
Battery Mode Off
Flashes Every 10 Seconds
Off Off
Battery Low On Flashes Every 1 Second Off Sounds Every 1 Second
Overload Alarm - Line Mode Off Off On
Sounds Every 0.5 Second
Overload Alarm - Battery Mode Off Flashes Every 1 second Off
Sounds Every 0.5 Second
Overload - Line Mode On Off Off Sounds Continuously
Overload - Battery Mode Off Off Off Off
Replace Battery Flashes Every Minute Off On Sounds Every Minute
Fault Condition On Off Off Sounds Continuously
6
Features
1 ON/OFF Button: When the UPS is on, press this button to turn the UPS off.
2 LED Indicators: Provides current status of the UPS. See LED Indicators for detailed description.
3 Battery Backup/Surge Protected Outlets: These outlets offer battery backup support and premium surge suppression for critical
devices requiring battery backup support.
4 AC Power Input: Use the Australian power cord to connect the OMNIVSX650A to the main power source.
5 Replaceable Input Fuse: Protects your electrical circuit from overcurrent draw from the UPS load. If the fuse has blown, remove some of
the load, then replace the fuse. The fuse is rated for 5A/250V AC.
UPS Features
Front Panel 1
4
5
2
3
Rear Panel
7
Storage
To avoid battery drain, all connected equipment should be turned off and disconnected from the UPS. Press and hold the power button for
one second and disconnect the unit from AC power. Your UPS will be completely turned off (deactivated), and will be ready for storage. If you
plan on storing your UPS for an extended period, fully recharge the UPS batteries every three months. Plug the UPS into a live AC outlet, turn
it on by pressing and holding the power button for one second, and allow the batteries to recharge for 4 to 6 hours. If you leave your UPS
batteries discharged for a long period of time, they will suffer a permanent loss of capacity.
Service
A variety of Extended Warranty and On-Site Service Programs are available from Tripp Lite. For more information on service, visit
tripplite.com/support. Before returning your product for service, follow these steps:
1. Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of
the instructions.
2. If the problem continues, do not contact or return the product to the dealer. Instead, visit tripplite.com/support.
3. If the problem requires service, visit tripplite.com/support and click the Product Returns link. From here you can request a Returned Material
Authorisation (RMA) number, which is required for service. This simple on-line form will ask for your unit’s model and serial numbers, along
with other general purchaser information. The RMA number, along with shipping instructions will be emailed to you. Any damage (direct,
indirect, special or consequential) to the product incurred during shipment to Tripp Lite or an authorised Tripp Lite service centre is not
covered under warranty. Products shipped to Tripp Lite or an authorised Tripp Lite service centre must have transportation charges prepaid.
Mark the RMA number on the outside of the package. If the product is within its warranty period, enclose a copy of your sales receipt.
Return the product for service using an insured carrier to the address given to you when you request the RMA.
Storage and Service
Battery Replacement
Under normal conditions, the original battery in your UPS will last several years. Battery replacement should only be performed by qualified
personnel. Refer to Battery Warnings in for complete battery safety information.
Model OMNIVSX650A requires one 12V DC, 7AH replacement battery.
For further information about replacement compatibility and ordering, visit tripplite.com/products/battery-finder.
Battery replacement must be performed using the same battery type and quantity: 12V DC sealed lead acid (SLA),
6 cell, and in compliance with UL 1989.
Risk of energy hazard. Before replacing batteries, remove conductive jewelry such as chains, wrist watches and rings.
High energy passing through conductive materials may cause severe burns.
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
20-02-311 93-3C68_RevA
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number
can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this
product, always refer to the series number. The series number should not be confused with the marketing name or model number of the product.
EMC Specifications for Models with EMC Category C2 Approval (Select Models):
WARNING: This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required
to take additional measures.
WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)
Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when customers buy new electrical and electronic
equipment from Tripp Lite they are entitled to:
• Send old equipment for recycling on a one-for-one, like-for-like basis (this varies depending on the country)
• Send the new equipment back for recycling when this ultimately becomes waste
Tripp Lite has a policy of continuous improvement. Product specifications are subject to change without notice.
Regulatory Compliance
Note on Labeling
Two symbols are used on the label.
V~ : AC Voltage
V : DC Voltage