Safety
Read the following information before installing or operating your APC Rack Power
Distribution Unit (PDU).
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• The Rack PDU is intended to be installed and operated by a skilled person in a
controlled location.
• Do not operate the Rack PDU with the covers removed.
• This Rack PDU is intended for indoor use only.
• Do not install this Rack PDU where excessive moisture or heat is present.
• Never install any wiring, equipment, or Rack PDUs during a lightning storm.
• Plug this Rack PDU into a grounded power outlet only. The power outlet must be
connected to appropriate branch circuit/mains protection (fuse or circuit breaker).
Connection to any other type of power outlet may result in a shock hazard.
• Do not use extension cords or adapters with this Rack PDU.
• If a socket-outlet is not accessible to the equipment, a socket-outlet shall be
installed.
• Do not work alone under hazardous conditions.
• Check that the power cord, plug, and socket are in good condition.
• Disconnect the Rack PDU from the power outlet before you install or connect
equipment to reduce the risk of electric shock when you cannot verify grounding.
Reconnect the Rack PDU to the power outlet only after you make all connections.
• Do not handle any kind of metallic connector before the power has been removed.
• Use one hand, whenever possible, to connect or disconnect signal cables to avoid a
possible shock from touching two surfaces with different grounds.
• This unit does not have any user-serviceable parts. Repairs are to be performed only
by factory-trained service personnel.
• High leakage current from attached loads is possible. If total leakage current will
exceed 3.5mA, attach a ground wire from the Rack PDU supplementary ground (M5
thread) to a reliable ground in your facility before energizing the Rack PDU
Failure to follow these instructions will result in death or serious injury.
WARNING
FIRE HAZARD
• This equipment should be connected to a single-outlet dedicated circuit protected by
a circuit breaker or fuse with the same current rating as the Rack PDU.
• The plug or inlet serves as the disconnect for the Rack PDU. Make sure the utility
power outlet for the Rack PDU will be close to the Rack PDU and readily accessible.
Failure to follow these instructions can result in death or serious injury.
Easy PDU Metered-by-Outlet with Switching
Rack Power Distribution Unit Installation
Worldwide Customer Support
Customer support for this product is available at www.apc.com
© 2021 Schneider Electric.
APC and the APC logo are trademarks owned by Schneider Electric SE.
All other brands may be trademarks of their respective owners.
Overview
This sheet provides installation information for your Easy PDU. Read the instructions
carefully.
Receiving
Inspect the package and contents for shipping damage. Make sure all parts were sent.
Immediately report any shipping damage to the shipping agent. Report missing
contents, product damage, or other problems with the product to APC or your APC
reseller.
Material Recycling
The shipping materials are recyclable. Please save them for later use, or dispose of
them appropriately.
EPDU1116SMBO
EPDU1132SMBO EPDU1232SMBO
EPDU1216SMBO
990-91568 12/2021
Installation
Option 1 - Vertical Installation with Brackets
1. Install the two (2) brackets to the Rack PDU with the screws provided.
2. Install the PDU to the rack
with the provided four (4)
M5 x10 mm self-tapping
screws.
Option 2 - Toolless Mounting Pegs
The mounting pegs of the Rack PDU are
installed at the factory. Slide both mounting
pegs into the holes located in the channel in
the rear panel of the rack. Snap the Rack PDU
into place by pushing it downward until it locks
into position.
NOTE: When installing the Rack PDU, ensure
that the power cord plug is accessible and that
it is connected to a grounded outlet.
pd u0 89 1a
pd u0 888 a
pdu0890b
How to Activate Your Warranty with the mySchneider
APP
1. Download the mySchneider app from the iTunes® or Google Play® app stores.
2. Log in or register your account.
3. Select Catalog, then tap on the Search bar. Either enter your product model number/
commercial reference or scan the QR code on your product to find your product in the
catalogue.
4. Select Register Asset and follow the prompts to validate your product details.
Display Interface
To configure the network settings and access the Rack PDU
Connect the network cable to the Network port and apply power to the unit.
To access the Rack PDU software interface, enter the IP address in your browser
address field. You will be prompted for a user name and password. Enter the default
“apc” for each. See the User Guide for this device online at www.apc.com for more
detailed information.
Item Function Description
LCD Display Show information about the Rack PDU.
Scroll Button Use the Scroll button to move through displayed
information.
OK Button With a menu option highlighted, press the OK
button to display Rack PDU information.
RJ45 Serial Port
Port for connecting the Rack PDU to a terminal
emulator program for local access to the command
line interface.
Out Port RS485 port sharing connection.
USB Port Connect a flash drive for firmware upgrades or to
download data logs.
10/100 Base-T
Connector Connect the Rack PDU to the network.
In Port RS485 port sharing connection.
Temp/Humidity Port Temp/Humidity Sensor connection port.
Main Menu Button Press to view the Rack PDU electrical input.
Reset Button Reset the Rack PDU without affecting the status of
the outlets.
pdu1100a
R
OK
T/H
In
Out
Network
Serial
Specifications
EPDU1116SMBO EPDU1132SMBO EPDU1216SMBO EPDU1232SMBO
Electrical
Nominal Input
Voltage
200-240 VAC
1 PHASE 200-240 VAC
1 PHASE
200/346 V-240/
415 V
200/346 V-240/
415 V
Maximum Input
Current (Phase) 16 A 32 A 16 A 32 A
Input Frequency 50/60 Hz
Input Connection IEC309 16 A
2P+E
IEC309 32 A
2P+E
IEC309 16 A
3P+N+PE
IEC309 32 A
3P+N+PE
Output Voltage 200 - 240 VAC
Maximum Output
Current (Outlet) 10 A (C13), 16 A (C19)
Output
Connections
Twenty (20) C13
Four (4) C19
Bank 1:
Ten (10) C13,
Two (2) C19
Bank 2:
Ten (10) C13,
Two (2) C19
L1:
Six (6) C13,
Two (2) C19
L2:
Six (6) C13,
Two (2) C19
L3:
Six (6) C13,
Two (2) C19
L1 Bank 1:
Three (3) C13,
One (1) C19
L1 Bank 2:
Three (3) C13,
One (1) C19
L2 Bank 3:
Three (3) C13,
One (1) C19
L2 Bank 4:
Three (3) C13,
One (1) C19
L3 Bank 5:
Three (3) C13,
One (1) C19
L3 Bank 6:
Three (3) C13,
One (1) C19
Overcurrent
Protection None
Two (2) 16 A
1 Pole Hydraulic-
Magnetic Circuit
Breakers
None
Six (6) 16 A
1 Pole Hydraulic-
Magnetic Circuit
Breakers
Physical
Dimensions
(H x W x D)
1800 x 55 x 56 mm
(70.86 x 2.16 x 2.20 in)
Input Power
Cord Length 3 m (10 ft)
Shipping
Dimensions
(H x W x D)
2030 x 195 x 130 mm
(79.92 x 7.68 x 5.12 in)
Weight/
Shipping Weight
6.67 kg (14.70 lb)/
7.84 kg (17.28 lb)
7.42 kg (16.36
lb)/
8.59 kg (18.94 lb)
7.12 kg (15.70 lb)/
8.29 kg (18.28 lb)
8.68 kg (19.14 lb)/
9.85 kg (21.72 lb)
Environmental
Maximum
Elevation
(Above MSL)
Operating/
Storage
0–3000 m (0–10,000 ft) /
0–15000 m (0–50,000 ft)
Temperature:
Operating/
Storage
–5 to 45°C (23 to 113°F)/
–25 to 65°C (–13 to 149°F)
Humidity:
Operating/
Storage
5–95% RH, Non-condensing
Compliance
EMC Verification
EN55035, EN55032,EN61000-3-3,EN61000-3-2,
BS EN55035, BS EN55032,
BS EN61000-3-3, BS EN61000-3-2
Safety
Verifica-
tion CE, TUV (EN62368-1), RCM, UKCA
CE EU Contact
Address
Schneider Electric, 35 rue Joseph Monier
92500 Rueil Malmaison, France
Environmental RoHS & Reach
Life Support Policy
General Policy
Schneider Electric does not recommend the use of any of its products in the following situations:
• In life-support applications where failure or malfunction of the Schneider Electric product can
be reasonably expected to cause failure of the life-support device or to affect significantly its
safety or effectiveness.
• In direct patient care.
Schneider Electric will not knowingly sell its products for use in such applications unless it receives in
writing assurances satisfactory to Schneider Electric that (a) the risks of injury or damage have been
minimized, (b) the customer assumes all such risks, and (c) the liability of Schneider Electric is
adequately protected under the circumstances.
Examples of Life-support Devices
The term life-support device includes but is not limited to neonatal oxygen analyzers, nerve
stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices,
blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems,
peritoneal dialysis systems, neonatal ventilator incubators, ventilators (for adults and infants),
anesthesia ventilators, infusion pumps, and any other devices designated as “critical” by the U.S.
FDA.
Hospital-grade wiring devices and leakage current protection may be ordered as options on many
Schneider Electric UPS systems. Schneider Electric does not claim that units with these
modifications are certified or listed as hospital-grade Schneider Electric or any other organization.
Therefore these units do not meet the requirements for use in direct patient care.
Radio Frequency Interference
Changes or modifications to this unit not expressly approved by the party responsible for compliance
could void the user's authority to operate this equipment.
Two-Year Factory Warranty
This warranty applies only to the products you purchase for your use in accordance with this manual.
Terms of Warranty
Schneider Electric warrants its products to be free from defects in materials and workmanship for a
period of two years from the date of purchase. Schneider Electric will repair or replace defective
products covered by this warranty. This warranty does not apply to equipment that has been
damaged by accident, negligence or misapplication or has been altered or modified in any way.
Repair or replacement of a defective product or part thereof does not extend the original warranty
period. Any parts furnished under this warranty may be new or factory-remanufactured.
Non-Transferable Warranty
This warranty extends only to the original purchaser who must have properly registered the product.
The product may be registered at the Schneider Electric Web site, www.apc.com.
Exclusions
Schneider Electric shall not be liable under the warranty if its testing and examination disclose that
the alleged defect in the product does not exist or was caused by end user’s or any third person’s
misuse, negligence, improper installation or testing. Further, Schneider Electric shall not be liable
under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical
voltage or connection, inappropriate on-site operation conditions, corrosive atmosphere, repair,
installation, exposure to the elements, Acts of God, fire, theft, or installation contrary to Schneider
Electric recommendations or specifications or in any event if the Schneider Electric serial number has
been altered, defaced, or removed, or any other cause beyond the range of the intended use.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR
OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT
OR IN CONNECTION HEREWITH. SCHNEIDER ELECTRIC DISCLAIMS ALL IMPLIED
WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR
PURPOSE. SCHNEIDER ELECTRIC EXPRESS WARRANTIES WILL NOT BE ENLARGED,
DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF,
SCHNEIDER ELECTRIC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN
CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES
SET FORTH ABOVE CONSTITUTE SCHNEIDER ELECTRIC’S SOLE LIABILITY AND
PURCHASER’S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES.
SCHNEIDER ELECTRIC WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT
EXTENDED TO ANY THIRD PARTIES.
IN NO EVENT SHALL SCHNEIDER ELECTRIC, ITS OFFICERS, DIRECTORS, AFFILIATES OR
EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR
PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE
PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF
FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER SCHNEIDER ELECTRIC HAS
BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY,
SCHNEIDER ELECTRIC IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR
REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE,
LOSS OF DATA, COSTS OF SUBSTITUTES, CLAIMS BY THIRD PARTIES, OR OTHERWISE.
NO SALESMAN, EMPLOYEE OR AGENT OF SCHNEIDER ELECTRIC IS AUTHORIZED TO ADD
TO OR VARY THE TERMS OF THIS WARRANTY. WARRANTY TERMS MAY BE MODIFIED, IF AT
ALL, ONLY IN WRITING SIGNED BY A SCHNEIDER ELECTRIC OFFICER AND LEGAL
DEPARTMENT.
Warranty Claims
Customers with warranty claims issues may access the Schneider Electric customer support network
through the Support page of the Schneider Electric Web site, www.apc.com/support. Select your
country from the country selection pull-down menu at the top of the Web page. Select the Support tab
to obtain contact information for customer support in your region.