ATEN Altusen™
SN3001 / SN3001P
SN3002 / SN3002P
RS-232 Secure Device Server
Secure Device Server User Manual
ii
EMC Information
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE
STATEMENT
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC Caution
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.
Warning
Operation of this equipment in a residential environment could cause radio
interference.
Achtung
Der Gebrauch dieses Geräts in Wohnumgebung kann Funkstörungen
verursachen.
KCC Statement:
Industry Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
Secure Device Server User Manual
iii
RoHS
This product is RoHS compliant.
About This Manual
This manual is provided to help you get the most out of your Secure Device
Server. It covers all aspects of the device, including installation, configuration,
and operation.
The Secure Device Server models covered in this user manuals include:
An overview of the information found in the manual is provided below.
Chapter 1, Introduction, introduces Secure Device Server. Its purpose,
features and benefits are presented, and its front and back panel components
are described.
Chapter 2, Hardware Setup, provides step-by-step instructions for setting
up Secure Device Server.
Chapter 3, Network Configuration and Login, explains how to log into
the Secure Device Server from a web browser.
Chapter 4, Web Console, explains the administrative procedures that are
employed to configure the Secure Device Server’s working environment.
Chapter 5, User Management, details login accounts and third-party
authentication services supported, such as RADIUS.
Chapter 6, Port Operating Modes, introduces the Secure Device Server’s
operating modes, and explains the purpose of each.
Chapter 7, Port Access, describes how to access the COM ports of the
Secure Device Server and start SNViewer.
Models Product Names
SN3001 1-Port RS-232 Secure Device Server
SN3001P 1-Port RS-232 Secure Device Server with PoE
SN3002 2-Port RS-232 Secure Device Server
SN3002P 2-Port RS-232 Secure Device Server with PoE
Secure Device Server User Manual
iv
Chapter 8, Remote Terminal Operation, describes how the Secure
Device Server can be accessed via remote terminal sessions, such as Telnet,
SSH, and PuTTY.
Chapter 9, Virtual Serial Port Manager, shows how to install the virtual
COM port driver and to set up and manage the virtual COM port.
Chapter 10, Serial Network Device Manager, explains how to use the
Serial Network Device Management utility to create and maintain device
groups for easy management of the serial ports on your installation; and as an
AP alternative to the browser-based management utilities.
Appendix, provides technical and troubleshooting information at the end of
the manual.
Conventions
This manual uses the following conventions:
Monospaced Indicates text that you should key in.
[ ] Indicates keys you should press. For example, [Enter] means to
press the Enter key. If keys need to be chorded, they appear
together in the same bracket with a plus sign between them:
[Ctrl+Alt].
1. Numbered lists represent procedures with sequential steps.
♦Bullet lists provide information, but do not involve sequential
steps.
>Indicates selecting an option (such as on a menu or dialog box),
that comes next. For example, Start
>
Run means to open the
Start menu, and then select Run.
Indicates critical information.
Secure Device Server User Manual
v
Package Contents
SN3001 / SN3002
The standard SN3001 / SN3002 package consists of:
1 Secure Device Server (SN3001 / SN3002)
1 power adapter
1 terminal block
1 foot pad set (4 pcs)
1 DIN rail mount kit
1 user instructions*
SN3001P / SN3002P
The standard SN3001P / SN3002P package consists of:
1 Secure Device Server with PoE (SN3001P / SN3002P)
1 terminal block
1 foot pad set (4 pcs)
1 DIN rail mount kit
1 user instructions*
Check to make sure that all of the components are present and in good order.
If anything is missing, or was damaged in shipping, contact your dealer for
assistance.
Read this manual thoroughly and follow the installation and operation
procedures carefully to avoid any damage to the Secure Device Server or to any
other devices on the Secure Device Server installation.
*Features may have been added to the Secure Device Server since this manual
was released. Please visit our website to download the most up to date
version of the manual.
Secure Device Server User Manual
vi
Product Information
For information about all ATEN products and how they can help you connect
without limits, visit ATEN on the web or contact an ATEN authorized reseller.
Visit ATEN on the web for a list of locations and telephone numbers:
User Information
Online Registration
Be sure to register your product at our online support center:
Telephone Support
For telephone support, call this number:
International http://www.aten.com
North America http://www.aten-usa.com
International http://eservice.aten.com
International 886-2-8692-6959
China 86-400-810-0-810
Japan 81-3-5615-5811
Korea 82-2-467-6789
North America 1-888-999-ATEN ext 4988
1-949-428-1111
Secure Device Server User Manual
vii
User Notice
All information, documentation, and specifications contained in this manual
are subject to change without prior notification by the manufacturer. The
manufacturer makes no representations or warranties, either expressed or
implied, with respect to the contents hereof and specifically disclaims any
warranties as to merchantability or fitness for any particular purpose. Any of
the manufacturer's software described in this manual is sold or licensed as is.
Should the programs prove defective following their purchase, the buyer (and
not the manufacturer, its distributor, or its dealer), assumes the entire cost of all
necessary servicing, repair and any incidental or consequential damages
resulting from any defect in the software.
The manufacturer of this system is not responsible for any radio and/or TV
interference caused by unauthorized modifications to this device. It is the
responsibility of the user to correct such interference.
The manufacturer is not responsible for any damage incurred in the operation
of this system if the correct operational voltage setting was not selected prior
to operation. PLEASE VERIFY THAT THE VOLTAGE SETTING IS
CORRECT BEFORE USE.
Secure Device Server User Manual
viii
Contents
EMC Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
SN3001 / SN3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
SN3001P / SN3002P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vi
User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vi
Online Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vi
Telephone Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .vi
User Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Chapter 1.
Introduction
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Serial-to-Ethernet Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SN3001 / SN3001P / SN3002 / SN3002P Front View . . . . . . . . . . . . . . . . 4
SN3001 / SN3001P / SN3002 / SN3002P Rear View . . . . . . . . . . . . . . . . 4
SN3001 / SN3001P / SN3002 / SN3002P Top View . . . . . . . . . . . . . . . . . 5
Chapter 2.
Hardware Setup
Before you Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Placement Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wall Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DIN Rail Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Parallel DIN Rail Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Perpendicular DIN Rail Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Rack Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Serial Port Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chapter 3.
Network Configuration and Login
IP Address Determination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Secure Device Server User Manual
ix
IP Installer Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Without IP Installer (non-DHCP only) . . . . . . . . . . . . . . . . . . . . . . . . .18
Logging In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Quick Setup Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Serial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Chapter 4.
Web Console
Web Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Serial Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Editing Serial Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Port Buffering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
General Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Notification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
SMTP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Syslog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Advanced. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Access Protection (IP Filter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Security Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Account Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Security Certificate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Update & Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Firmware Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Backup & Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
User Accounts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Chapter 5.
User Management
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
User. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Adding Users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Editing Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Deleting Users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Secure Device Server User Manual
x
Online Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Authentication Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
RADIUS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Chapter 6.
Port Operating Modes
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Selecting Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Real COM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
TCP Server & Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
TCP Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
TCP Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Serial Tunneling Server & Client. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
UDP Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Console Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Console Management Direct. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Chapter 7.
Port Access
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Telnet / SSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
SNViewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Control Panel Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Data Import . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Encode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Terminal Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Chapter 8.
Remote Terminal Operation
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Terminal Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Telnet Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
SSH Login (Linux). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Third-party Utility (Windows). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Terminal Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Chapter 9.
Virtual Serial Port Manager
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Secure Device Server User Manual
xi
Real COM Port Management — Virtual Serial Port Manager. . . . . . . . . . 72
Utility Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Menu and Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Target Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Target List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Port List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Port Mapping and Unmapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
Port Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Mapped COM Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Port Unmapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Real COM Port Management — Linux Commands . . . . . . . . . . . . . . . . . 78
Mapping / Unmapping Virtual Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Virtual Port Naming Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Appendix
Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
DC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
International. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
North America . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Clear Login Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Limited Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Secure Device Server User Manual
xii
This Page Intentionally Left Blank
1
Chapter 1
Introduction
Overview
The Secure Device Server provides security-assuring, IP-based LAN
connectivity for RS-232 serial devices and supports a wide range of operation
modes. It empowers everyday RS-232 serial device — PLCs, meters, and
sensors — to be connected to a network, and allowing them to be accessed and
managed from anywhere over the network.
Equipped with extensive security features, such as Secure Real COM, Secure
TCP Client and Server, Secure Serial Tunneling, and Secure Console
Management, the Secure Device Server is the ideal solution for managing RS-
232 serial device in a wide range of security-critical applications.
Fully compatible with existing serial communication software, the Secure
Device Server ensures that your former investments in software development
are protected. Software designed to work with COM or TTY ports can access
the serial devices connected over a TCP/IP network by utilizing the Secure
Device Server’s Real COM or TTY drivers. This feature also breaks through
the port number and distance limitation barriers encountered with PC
hardware.
With SSL and SSH protocol support — for encrypting data transmission — the
Secure Device Server ensures secured data transmission over both private and
public networks.
Installing the Secure Device Server is fast and easy: plugging cables into their
appropriate ports is all that is entailed. It also offers a browser-based GUI,
Telnet / SSH console sessions, and a Windows software utility, making
configuration and operation swift and smooth.
SN3001P / SN3002P provides PoE function, IEEE 802.3af compliant, thus can
be powered through an Ethernet cable, by a PoE switch/adapter, without
requiring an additional power supply.
All in all, with its advanced features and ease of operation, the Secure Device
Server is the most convenient, reliable, and cost-effective way to remotely
manage your serial devices.
Secure Device Server User Manual
2
Features
Serial-to-Ethernet Connectivity
1 or 2 RS-232 serial ports for secured serial data over Ethernet
transmission
Secured operation modes — Secured Real COM, Secured TCP Server/
Client, Secured Serial Tunneling, Console Management (SSH), and
Console Management Direct (SSH)
Standard operation modes — Real COM, TCP Server/Client, Serial
Tunneling, UDP, Console Management (Telnet), and Console
Management Direct (Telnet)
Real COM, Real TTY, and Fixed TTY drivers for Windows, Linux, and
UNIX
Convenient console management access via Java viewer (SSH/Telnet) or
third-party clients such as PuTTY
Easy console port access via Java viewer and Sun Solaris ready (“break-
free”)
Multiple users can simultaneously access the same port — up to 16
connections per port
Hardware
Redundant power input (power jack and terminal block) for fail-safe
power
IEEE 802.3af-compliant PoE power device equipment (SN3001P /
SN3002P only)
Surge protection for serial, Ethernet, and power
Wall and DIN-rail mounting, rack mounting (optional kit VE-RMK1U
required), and desktop installation available
Supports baud rates of 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800,
7200, 9600, 19200, 38400, 57600, 115200, 230.4k, 460.8k, 921.6k bps
Chapter 1. Introduction
3
Security
Supports secured login from browsers with TLS 1.2 data encryption and
RSA 2048-bit certificates
Configurable user permissions for port access and control
Local and remote authentication and login
Third-party authentication (e.g. RADIUS)
IP address filter for security protection
System Management
Browser access with an intuitive GUI
Web-based quick setup wizard for fast configuration
Terminal-based access with a menu-driven UI via Telnet / SSH
Online / offline detection of connected serial devices (including terminal
blocks) — automatically send event notifications when the devices are
offline (e.g. power failure) for device status monitoring
System event logs will be saved to internal memory or Syslog server
Port logs will be saved to internal memory or Syslog server
SNMP agent (v1/v2c)
Event notification — supports notification of SMTP email and SNMP trap
(v1/v2c)
Backup / restore system configuration and upgradable firmware
64 Kbyte port buffer prevents data loss when the network is down
NTP for time server synchronization
Multi-language web-based GUI
Secure Device Server User Manual
4
SN3001 / SN3001P / SN3002 / SN3002P Front View
SN3001 / SN3001P / SN3002 / SN3002P Rear View
No. Component Description
1 RS-232 serial
port 1
Connects to an RS-232 serial device.
2 RS-232 serial
port 2
Connects to a second RS-232 serial device. (SN3002 /
SN3002P only)
No. Component Description
1 LAN port Connects the Secure Device Server to the network. For
SN3001P / SN3002P (PoE 802.3af compliant), it can be
simultaneously supplied power through a PoE switch.
2 reset button Pressing and holding for less than three seconds performs
a system restart. Pressing and holding for more than three
seconds returns its settings (excluding user account
settings and privileges) to their default status.
3 power terminal Connects the Secure Device Server to power via DC
electric leads and the terminal block provided.
4 power jack Connects the Secure Device Server to power using a power
adapter.
32
42 5
3
Chapter 1. Introduction
5
SN3001 / SN3001P / SN3002 / SN3002P Top View
No. Component Description
1 grounding
terminal
Grounds the unit by connecting to a suitable grounded
object using a grounding wire.
2 serial port 1
LED
Lights green or orange when data is being sent or received
via the unit’s RS-232 serial port 1.
3 serial port 2
LED
Lights green or orange when data is being sent or received
via the unit’s RS-232 serial port 2. (SN3002 / SN3002P
only)
4 status LED Lights or blinks yellow/green respectively for normal
operation or startup, and lights red when an error (i.e.
hardware failure and DHCP irregularity) occurs.
5 power LED Lights green when the Secure Device Server is powered
and ready.
532 64
Secure Device Server User Manual
6
This Page Intentionally Left Blank
7
Chapter 2
Hardware Setup
Before you Begin
Placement Options
For flexibility and convenience, Secure Device Server can be mounted onto a
wall or DIN rail, as described below.
Wall Mount
To wall mount the Secure Device Server, doe the following:
Using 4 self-supplied screws, users can mount the unit onto a wall via the screw
holes at its sides, as shown below.
1. Important safety information regarding the placement of this
device is provided on page 79. Please review it before
proceeding.
2. Make sure the power of all devices to be connected have been
turned off.
Secure Device Server User Manual
8
DIN Rail Mount
Use the DIN rail mount kit included to mount the Secure Device Server onto a
DIN rail, as instructed below:
Parallel DIN Rail Mount
1. To mount the unit parallel to the DIN rail, attach 2 DIN rail mount brackets
onto the unit with the 4 screws provided, via its center screw holes.
2. Hang the unit onto the DIN rail.
Chapter 2. Hardware Setup
9
Perpendicular DIN Rail Mount
1. Attach the L-shape mounting bracket onto the unit with 2 M3x6 screws,
via its center screw holes at the side opposite to its grounding terminal.
2. Using 2 of the 4 screws enclosed, attach 1 DIN rail mount bracket onto the
side of the L-shape mounting bracket.
3. Hang the unit onto the DIN rail.
Secure Device Server User Manual
10
Rack Mount
The Rack Mount Kit (VE-RMK1U) is required for mounting the Secure
Device Server onto a rack, as instructed below:
1. Place the device onto the mounting plate while latching one of its rack ears
onto the plate’s protruded dot, as illustrated below.
2. Secure the device to the mounting plate using the hexagon head screw
supplied. Users can secure the Secure Device Server either with its serial
port(s) facing inward or outward.
Mounting Plate
Protruded dot
Protruded dot
Chapter 2. Hardware Setup
11
3. Position and align the holes on the VE-RMK1U frame with that of the
rack, and secure the frame onto the rack with 2 self-supplied screws, as
illustrated below.
Secure Device Server User Manual
12
4. Align the device and mounting plate assembly to one of the slots on the
VE-RMK1U frame, and then secure the mounting plate to the frame with
the plastic captive screw provided.
Note: Up to 4 Secure Device Servers can be secured onto a VE-RMK1U frame.
VE-RMK1U Frame
slot 1
slot 2 slot 3 slot 4
Chapter 2. Hardware Setup
13
Installation
To install the Secure Device Server, follow the steps below and refer to the
diagram on the following page (the number labels correspond to the installation
steps).
1. Use a grounding wire to ground the unit by connecting one end of the
grounding terminal and the other end to a suitable grounded object.
Note: Do not omit this step. Proper grounding helps prevent damage to the
unit from power surges and static electricity.
2. Connect the unit’s RS-232 serial port(s) to one or up to two serial
device(s).
3. Connect the unit’s LAN port to the network using a Cat 5e/6 cable. For
SN3001P / SN3002P (PoE 802.3af compliant), users can simultaneously
supply power to the unit through a PoE switch and skip 4.
2
3
ST.343ST.343
Secure Device Server User Manual
14
4. Connect the unit to power, thereby turning it on, by doing one, or both of
the following for power redundancy:
Plug the power adapter provided (not included for SN3001P /
SN3002P) into an AC power source, and plug its cable into the unit’s
power jack.
Note: The temperature tolerance of the power adapter is 0 – 40 °C. If
your environment temperature is 40 – 60 °C, you can only power
the device via the power terminal.
Connect DC + and - wires (DC 9 – 48 V) to the unit’s power terminal
with the terminal block provided.
5. After supplying power, wait for about 50 seconds for the Secure Device
Server to be ready and lights its status LED in constant green.
Note: When more than one power supply is connected, the additional power
connections maintain operation when the other is interrupted. For example, if
you have the device connected to power via both its power jack and power
terminal, the power terminal maintains operation when the power from the
power jack fails, and vice versa.
4 5
QpxfsQpxfsOfuxpsl
Chapter 2. Hardware Setup
15
Serial Port Pin Assignments
The pin assignments of Secure Device Server’s RS-232 serial ports are
provided below:
Pin
Configuration
RS-232
1 DCD
2RxD
3TxD
4DTR
5GND
6DSR
7RTS
8CTS
Secure Device Server User Manual
16
This Page Intentionally Left Blank
17
Chapter 3
Network Configuration and Login
IP Address Determination
Before you start, make sure the PC you’re using is within the same LAN as the
Secure Device Server.
There are two methods for determining / setting the IP address of your Secure
Device Server, one through the IP Installer Utility on a Windows PC, and one
just using a PC (only applicable to non-DHCP network), as described below:
IP Installer Utility
Using a Windows PC, users can search for Secure Device Server’s IP address
or assign an IP address to it, in a DHCP or non-DHCP network, with the IP
Installer Utility.
1. Download IP Installer zip file under the Support and Downloads tab from
the product web page.
2. Extract and execute IPInstaller.exe. A dialog box similar to the one below
appears.
Secure Device Server User Manual
18
3. :Select the Secure Device Server in the Device List.
Note: 1. If the list is empty, or your device doesn't appear, double-check
that you have the correct network adapter selected and click
Enumerate to refresh the Device List.
2. If there is more than one device in the list, use the MAC address
to distinguish your device. The Secure Device Server’s MAC
address is located on its bottom panel.
4. To check the IP address of the Secure Device Server or set an IP address
for it, respectively select Obtain an IP address automatically or Use the
following IP address.
For setting an IP address, fill in the required IP address, subnet mask
and gateway information according to your network environment.
5. Click Set IP. The IP address of the Secure Device Server is displayed in
the Device List.
6. Click Exit to close the program.
Without IP Installer (non-DHCP only)
On a non-Windows system, under non-DHCP network, users can assign a static
IP address to the Secure Device Server, different from its default of
192.168.0.60, by following the steps below.
1. Set your PC’s IP address to 192.168.0.XXX, where XXX can be any
number except for 10.
2. Type the device’s default IP address — 192.168.0.60 — in your browser’s
URL location bar.
3. Log in with a valid username and password (see page 19).
4. On the Secure Device Server’s web interface, assign a fixed IP address for
it according to your network environment.
5. Save the settings and log out. After you log out, make sure to reset your
PC’s IP address to its original value.
Chapter 3. Network Configuration and Login
19
Logging In
To access Secure Device Server from a web browser, do the following:
1. Open your browser and specify the IP address of the Secure Device Server
you want to access in the browser's URL location bar.
Note: If you are the administrator, and are logging in for the first time, the
various ways to determine the Secure Device Server's IP address are
described in IP Address Determination (see page 17).
2. If a Security Alert dialog box appears, accept the certificate — it can be
trusted (see Security Certificate, page 43, for details). If a second
certificate appears, accept it as well.
3. On the login page that appears, provide a valid username and password
to log in. The default Username and Password are administrator and
password, respectively.
4. Once successfully logged in, the main screen of the Secure Device Server
appears. Upon first-time login, users are required to change the login
password of the Secure Device Server.
5. Upon first-time login, users are required to change the login password of
the Secure Device Server.
6. Once logged in, the Quick Setup Wizard is displayed, which takes you
through the basic settings of the Secure Device Server.
Secure Device Server User Manual
20
Quick Setup Wizard
The Quick Setup Wizard gets you started with the basic settings of the Secure
Device Server.
General
Item Description
Device name Displays the name of the Secure Device Server. Change the
device name if needed.
Current time Displays the current time of the device.
Time settings Sets the time settings of the device. For details, refer to Time,
page 36.
Secure Device Server User Manual
22
Serial
Note: Settings on the Serial tab applies to all serial ports of the Secure Device
Server.
Click Save for the settings to take effect.The Secure Device Server’s web
console main screen is displayed. See Web Console for details.
Item Description
Mode Selects the operation mode for the Secure Device Server’s
serial port(s). See Port Operating Modes.
Secure transfer Check for secured data transmission.
Baud rate Selects the serial ports’ data transfer speed.
Parity Selects to check the integrity of the data transmitted, which
shall match the parity setting of the serial device(s) connected
Data bits Selects the number of bits used to transmit one character of
data, and matching the data bit setting of the serial device(s)
connected.
Stop bits Selects the stopping bit, indicating a character has been
transmitted, and matching the stop bit setting of the serial
device(s) connected.
23
Chapter 4
Web Console
Web Interface
The web interface of the Secure Device Server and its components are shown
and explained below:
No. Item Description
A Sidebar Menu Provides a selection of configuration pages. Click to select
a configuration page and/or expand submenus.
B Task Bar Contains access to the Quick Setup Wizard, user settings
(including logout) and the device info.
C Interactive Display
Panel
Displays the configuration page currently selected.
1 Quick Setup
Wizard
Takes users through the basic settings of the Secure
Device Server. See p. 20.
2 Personal Click to display the user currently logged in, the time of
login, user preference option, change password, and
logout options.
Click Preferences to change the language of the interface.
Click Change password to change the password for the
current user account.
3 About Click to display the model number and the firmware
version of the device.
A
B
C
231
Secure Device Server User Manual
24
Serial Ports
The Serial Ports page provides an overview of the Secure Device Server’s
serial COM ports, including its settings and the serial devices connected.
Editing Serial Ports
Click the EDIT button to modify the settings of a serial COM port. The edit
window, with Properties, Operating Mode, and Port Buffering tabs, appears.
Item Description
Indicates whether the serial port is online or offline.
Port Name Displays the name of the serial port.
Operating Mode Displays the current operating mode of the serial port.
See Operating Mode, page 27.
Ethernet Port Displays the network port value of the serial port.
Baud Rate Displays the baud rate of the serial port.
Online Indicates whether the serial port is online or offline.
In Use Indicates whether the serial port has active data transmission.
Action
Edit: Click to edit the serial port’s settings.
Dump Buffer: Click to download the port activity logs of the
serial port from the device as a .txt file. This function is only
available when the port activity logs are saved to the
device’s memory. See Port Buffering, page 26.
Telnet / SSH: Click to configure the Secure Device Server or
access and control the connected serial device via Telnet /
SSH protocol. This function is only available when the port’s
operating mode is set to Console Management.
See Operating Mode, page 27, and Telnet / SSH, page 62.
Note: The maximum number of simultaneous connections to
any one serial port is 16.
Chapter 4. Web Console
25
Properties
Click Save for the changes to take effect.
Optionally click Save & Apply All to apply the same settings to all of the
Secure Device Server’s serial ports.
Item Description
Port number Displays the number of the serial port.
Port name Sets the name of the serial port.
Baud rate Selects the serial ports’ data transfer speed. Default = “9600”
Parity Selects to check the integrity of the data transmitted, which
shall match the parity setting of the serial device connected.
Default = “None”
Data bits Selects the number of bits used to transmit one character of
data, and matching the data bit setting of the serial device
connected. Default = “8”
Stop bits Selects the stopping bit, indicating a character has been
transmitted, and matching the stop bit setting of the serial
device connected. Default = “1”
Flow control Selects how the data flow is controlled, and matching the flow
control setting of the serial device connected. Default = “None”
Secure Device Server User Manual
26
Port Buffering
Port buffering creates a log of the activities conducted when a port is accessed.
You can save the log to the internal memory of the Secure Device Server, for
up to 128 KB, or a Syslog server.
To enable Port Buffering, select Memory or Syslog Server from the drop-
down list in the Port Buffering tab. Optionally check Time Stamps to add time
stamps to the logs created.
Click Save for the changes to take effect.
Note: Before Syslog can be selected, make sure to enable Syslog server, see
Syslog, page 39.
Optionally click Save & Apply All to apply the same settings to all of the
Secure Device Server’s serial ports.
Chapter 4. Web Console
27
Operating Mode
The Operating Mode tab determines how the serial COM port of the Secure
Device Server is accessed.
Note: The maximum number of simultaneous connections to any one serial
port is 16.
For detailed information of the various port operating modes, see Chapter 6,
Port Operating Modes.
Real COM
Check Secure transfer to encrypt all data being transfered, using SSL, through
the serial COM port.
Note: Real COM operating mode must be used in conjunction with ATEN’s
Virtual COM Port Utility, see Virtual Serial Port Manager, page 71.
TCP Server
Item Description
Secure transfer Check to encrypt all data being transferred between Secure
Device Servers’ serial COM ports via TCP Server-Client
modes, using SSL.
Secure Device Server User Manual
28
TCP Client
Item Description
Secure transfer Check to encrypt all data being transferred between Secure
Device Servers’ serial COM ports via TCP Client-Server
modes, using SSL.
Destination host Enter the IP address and service port of a destination host for
data transmission. The device can simultaneously send data
to up to 16 destination hosts.
Chapter 4. Web Console
29
UDP
Item Description
Destination host Enter the range of IP address(es) and the port values for
connections to destination hosts via the UDP protocol. The
Secure Device Server can simultaneously connect to up to 16
destination hosts.
Secure Device Server User Manual
30
Serial Tunneling Server
Serial Tunneling Client
Item Description
TCP port Sets the TCP/IP port value of the serial port operating as a
serial tunneling server.
Secure transfer Check to encrypt all data being transferred through the serial
COM ports between two Secure Device Server via Serial
Tunneling Server-Client., using SSL.
Item Description
Destination Enter the IP address and port value of the serial tunneling
server for sending data to.
Secure transfer Check to encrypt all data being transferred through the serial
COM ports between two Secure Device Servers via Serial
Tunneling Client-Server, using SSL.
Chapter 4. Web Console
31
Console Management
Disable
Select to disable the use of the serial port.
Item Description
Connection protocol Check / uncheck to enable / disable SSH and Telnet
connection protocols.
Direct connection Select for Console Management Direct operating mode. For
detailed information on the various available operating modes,
see Chapter 6, Port Operating Modes.
Logout timeout
(0 ~ 180 min)
Automatically logs out user(s) accessing when there is no
input by the user for the amount of time set. “0” means the
user will never be automatically logged out.
Suspend character The suspend character is used to bring up the Suspend Menu
in Telnet sessions. Valid characters include A – Z, except for
H, I, J, and M.
Exit Macro Sets the Exit Macro that will be executed upon exiting the
serial device.
Map <CR-LF> Select to send Carriage Return (CR) and/or Line Feed (LF)
signals.
Secure Device Server User Manual
32
Network
The Network page contains the network settings of the Secure Device Server,
as described in the table below.
Item Description
Configuration Selects the type of configuration for setting the Secure Device
Server’s IP address, from DHCP or Static IP.
IP address
Subnet mask
Default gateway
For static IP, set the IP address, subnet mask, and gateway of
the device according to your network environment.
DNS Selects the method of obtaining DNS server, from Obtain
automatically or Set manually.
Preferred DNS server
Alternate DNS server
For setting the DNS server manually, type the preferred and
alternate DNS server address for the device.
Chapter 4. Web Console
33
System
Click to expand the System submenu for all of the system related settings of
the Secure Device Server, including General settings, Notification, Security,
and Update & Restore.
Secure Device Server User Manual
34
General Settings
The General Settings contains 2 tabs: General and Time.
General
Item Description
Device name Sets the device name for the Secure Device Server.
Description Enter a description for the device if needed.
MFG Displays the MFG (Manufacturing Number) of the device.
Note: The Manufacturing Number is an internal serial number
used by ATEN’s factory and technical support staff to identify
products.
MAC Displays the MAC address of the Secure Device Server.
Uptime Displays the amount of time the device has been running for.
Power source Displays the device’s current power source.
Chapter 4. Web Console
35
Click Save for the changes to take effect.
Login session timeout
(0 ~ 180 min)
Automatically logs out user(s) when there are no actions done
on the Secure Device Server’s web interface for the amount of
time set. “0” means the user will never be automatically logged
out.
Reboot System Reboots the Secure Device Server.
Service ports Sets the service port values for the following:
HTTP: used for browser access (default = 80)
HTTPS: used for secure browser access (default = 443)
SSH: used for SSH access (default = 22)
Telnet: used for Telnet access. (default = 23)
Base socket: used for receiving and accepting TCP
connections (default = 5001). For example, when the
base socket value is 5001, the device’s TCP port value
for Port 1/2 via Telnet and SSH will be 5001/5002 and
5101/5102, respectively.
Note:
1. Valid entries for all service ports are from 1 – 65535.
2. A system restart is required when any of the service
port settings have been changed.
IP Installer
Configuration
Select to determine if the IP Installer utility can detect for and/
or change the Secure Device Server‘s IP address.
Enabled: IP Installer can detect for and change the
unit’s IP address.
View Only: IP Installer can only detect for but unable to
change the unit’s IP address.
Disabled: IP Installer cannot detect for and change the
unit’s IP address.
Item Description
Secure Device Server User Manual
36
Time
The Time tab contains the time settings of the Secure Device Server, as
described in the table below.
Item Description
Time zone Select one of the following to set the time of the Secure Device
Server.
Synchronize with computer time: Synchronizes with the
time of the client PC.
Set manually: Manually set a desired time for the
device.
Synchronize with NTP Server: Synchronizes the time of
the device using an NTP server.
Note: If you use Synchronize with computer time or Set
manually, the time settings must be reconfigured whenever the
Secure Device Server is restarted.
Chapter 4. Web Console
37
Notification
The Notification page contains 4 tabs: SMTP, SNMP, Syslog, and Advanced.
SMTP
Item Description
Enable SMTP service Check to enable SMTP service for sending event notifications
via email, as specified by the Advanced tab (see page 40).
Server Address / Port Enter the SMTP server’s address and service port value.
Email Enter the sender’s email address.
My server requires
authentication
Check if your SMTP server requires authentication and enter a
valid username and password.
Recipient Enter the recipient’s email address.
Secure Device Server User Manual
38
SNMP
Note: Before SNMP can be used, make sure to Enable SNMP Agent service
in System > Security > Security Level.
Item Description
Send SNMP traps Check to enable SNMP service for sending SNMP trap event
notifications, as specified by the Advanced tab (see page 40).
SNMP v1 and v2c are supported.
IP/Server Address Enter the IP/server address to receive the SNMP trap events.
Port Enter the service port of the server to receive SNMP trap
events.
Community Enter the SNMP community.
SNMP Agent Enter the service port and community for an SNMP agent.
Secure Device Server User Manual
40
Advanced
The Advanced tab sets the types of event notifications to be sent via SMTP,
SNMP, and/or Syslog server. Options include but are not limited to the
example given below
Check the SMTP / SNMP / Syslog checkboxes next to each event type for
sending SMTP / SNMP / Syslog notifications when those events occur.
Note: For the specified notifications to be sent, make sure the required SMTP
/ SNMP / Syslog service have been properly configured.
Chapter 4. Web Console
41
Security
The Security page contains the security settings and certificate information of
the Secure Device Server, distributed into 4 tabs: Access Protection, Security
Level, Account Policy, and Certificate.
Access Protection (IP Filter)
The Access Protection function sets IP filters to allow remote access only from
the IP address(es) added, and denying all other remote access.
To enable exclusive access only for certain IP address(es), check Enable IP
filter, and click the ADD button to add the desired IP address(es).
Click Save for the changes to take effect.
Secure Device Server User Manual
42
Security Level
Account Policy
Item Description
Enable Telnet / SNMP
Agent / ICMP / SSH
service
Check or uncheck to enable or disable Telnet / SNMP Agent /
ICMP / SSH service.
Note: A system restart is required when the SNMP Agent
setting has been changed.
Enable HTTP and
redirect to HTTPS
Check to enable HTTP and automatically redirect all HTTP
access to HTTPS, for secured web browser access.
Note: A system restart is required when this setting has been
changed.
Item Description
Minimum length for
username / password
Sets the minimum number of characters required for all newly
set login usernames / passwords. Default = “6”
Password must
contain at least
Check to require at least one uppercase / lowercase / number
/ special character for all newly set passwords.
Chapter 4. Web Console
43
Security Certificate
The Security Certificate tab displays the information of the security certificate
used.
For enhanced security, users can use their own private encryption key and
signed certificate, rather than the default ATEN certificate.
There are two methods for establishing your private certificate:
Generating a Self-Signed Certificate
If you wish to create your own self-signed certificate, a free utility —
openssl.exe — is available for download over the web.
Obtaining a CA-Signed SSL Server Certificate
To ensure security, it is reco mmend ed to u se a third-party C A -signed SSL
certificate obtained from a CA (Certificate Authority) we bsite. Make sure
to save the obtained certificate and its private encryption key on the PC.
Secure Device Server User Manual
44
Update & Restore
The Update & Restore page can upgrade the Secure Device Server’s firmware
and back up and/or restore its device settings.
Firmware Update
Item Description
Import Certificate Imports a private or CA-signed security certificate from the PC.
Restore Defaults Reverts to using the default ATEN certificate.
Item Description
Firmware version Displays the current firmware version.
Upgrade with newer
firmware version only
Check to only permit firmware upgrades with newer firmware
versions.
Choose File Selects the firmware update file to be used for upgrading.
UPGRADE Upgrades the device firmware with the firmware file selected.
Chapter 4. Web Console
45
Backup & Restore
The Backup & Restore page allows users to back up or restore the system
settings of the Secure Device Server.
Backing up System Settings
To back up the system settings of the Secure Device Server, enter a Password,
which will be used for restoring, and click Backup to save the system setting
backup file, as System.conf, to the PC, which also include account-related
settings, such as passwords and user privileges.
Restoring System Settings
To restore a previously backed up system settings file, enter its Password, click
Choose File to locate it on the PC, and click Restore.
Secure Device Server User Manual
46
User Accounts
The User Accounts submenu consists of User and Authentication Services
pages, which allow users to add/edit login accounts or utilize third-party
authentication services for managing the user accounts of the Secure Device
Server, respectively.
For details on configuring user accounts and third-party authentication
services, see Chapter 5, User Management.
Chapter 4. Web Console
47
Logs
The Logs page lists all of the system log information of the Secure Device
Server.
Up to 2048 logs can be stored and displayed on this page.
Item Description
Export Exports and downloads the logs onto the PC as a log.txt file.
Clear All Clears all log information.
Secure Device Server User Manual
48
This Page Intentionally Left Blank
49
Chapter 5
User Management
Overview
This chapter takes users through how to add or edit the login accounts of Secure
Device Server, including the administrator, as well as using third-party
authentication services.
User
The Secure Device Server supports up to 16 user accounts, with two types of
users, as described below:
User Type Role
Administrator Able to access and configure all serial ports, and manage
other login accounts
User Only able to access and/or configure the authorized serial
ports, as permitted by the administrator, and unable to
configure any of the device’s system settings.
Item Description
Name Displays the username of the user account.
Type Displays the account type, Administrator or User.
Description Additional information used to describe the user account.
Status Displays the status of the user account, which includes:
Normal: The account functions normally.
Password Expired: The account’s password has expired
and must be changed.
Secure Device Server User Manual
50
Adding Users
1. Click User Accounts > User > Users on the web interface of the Secure
Device Server.
2. Click Add. The Add User window’s General tab appears. Enter the
required fields, as described in the table below.
Item Description
Username From 1 to 32 characters are allowed depending on the
Account Policy settings. See Account Policy, page 42.
Password From 1 to16 characters are allowed depending on the
Account Policy settings. See Account Policy, page 42.
Confirm Password Match the Password field to confirm the password entry.
Description Additional information about the user that you may wish to
include.
User type Select Administrator for full access and configuration rights
or select User permit only the access and configuration
rights of the serial ports, as set.
User cannot change
account password
Check to restrict the user from changing the account’s
password
User must change
password at next
login
Check to require the user to change his password upon next
login.
Chapter 5. User Management
51
3. Only for user types — User, click the Device tab to permit access and/or
configure rights for each serial port, as described in the table below.
4. Click Save to finish.
5. When the Operation Succeeded message appears, click OK.
Editing Users
To edit a user account, select it and click Edit.
In the Edit User window, make your changes by referring to Adding Users,
page 50, then click Save.
Password expires
on
Specifies the date on which the password of the login
account shall expire, and be redefined.
Note: After a user’s password expires, he can still log in with
the old password, but will be forced to change it upon login.
Item Description
No Access Select to restrict access to the serial port.
View Only Select to only allow view access to the serial port, while
restricting Telnet and SSH sessions.
Full Access Select to allow full access to the serial port.
Configuration Check to allow configuration for the serial port, including its
Properties, Operating Mode, and Port Buffering settings.
See Editing Serial Ports, page 24.
Item Description
Secure Device Server User Manual
52
Deleting Users
To delete user account(s), select them and click Delete.
When asked Are you sure to delete?, Click OK to confirm.
Online Users
The Online Users tab displays the user accounts that are currently accessing
the Secure Device Server.
The administrator can check to select any other user accounts currently logged
in, and click Disconnect to terminate those users’ access sessions.
Chapter 5. User Management
53
Authentication Services
The Secure Device Server allows external, third-party authentication services,
namely RADIUS for managing and authenticating its user accounts.
Note: When using RADIUS for authentication, only PAP is supported.
To enable such services, click User Accounts > Authentication Services on
its web interface.
RADIUS
1. To use authentication via RADIUS, enable the service on the Secure
Device Server, by referring to the table below.
Item Description
Preferred server IP/
address and server
port
Fill in the IP address and service port of the primary
(preferred) RADIUS server.
Alternate server IP/
address and server
port
Fill in the IP address and service port of the alternate
RADIUS server.
Timeout Sets the time, in seconds, that the Secure Device Server
shall wait for the RADIUS server for.
Retries Sets the number of allowed RADIUS retries.
Shared Secret (at
least 6 characters)
Enter the character string that you want to use for
authentication between the Secure Device Server and the
RADIUS server.
Secure Device Server User Manual
54
2. On the RADIUS server, set the access rights for each according to the
attribute information provided in the following table.
Example:
U, T, 1
The user can access and configure port 1.
Note: 1. The characters are not case sensitive, i.e. uppercase and lowercase
work equally well, and comma-separated.
2. An invalid character in the string will prohibit access to the Secure
Device Server for the user.
Attribute Description
U(User) The user has the authority to access and configure
some ports. This attribute must be specified for all users who
access the device.
T(True) The user has the authority to access and configure
the ports that are specified with it.
F (False) The user cannot configure any ports.
A (All) The user has the authority to access and configure all
ports.
55
Chapter 6
Port Operating Modes
Overview
To cover a broad range of serial applications, the Secure Device Server’s
COM port supports several po rt operating mode s.
These include Real COM, TCP Server & Client, UDP, and Serial Tunneling
Server & Client modes for serial-to-Ethernet connectivity, Console
Management, and Console Management Direct for device control, as well as
applications that require COM ports, serial tunneling, or where TCP/UDP
socket functionality is needed.
Note: The maximum number of simultaneous connections to any one serial
port is 16.
Selecting Operating Mode
The following are some of the questions to consider when selecting the
operating mode.
Secure Device Server User Manual
56
The Operating Mo de is selectable from Serial Ports > Edit > Oper ating
Mode, as shown below..
From this page, users can set the serial ports of the Secure Device Server to
the various Port Operating modes available, as explained below
Chapter 6. Port Operating Modes
57
Operating Mode
To configure the serial ports’ operating mode, see Operating Mode, page 27.
Real COM
This mode is used in conjunction with a virtual COM port driver installed on a
remote PC. (See Chapter 9, Virtual Serial Port Manager) When the Secure
Device Server’s COM port is set to this mode, the device connected appears as
if it were directly connected to a COM port on the remote PC.
This mode is useful with devices such POS terminals, bar code readers, serial
printers, etc. since it allows users to use software that was written for pure serial
communication applications. .
The Secure Device Server comes with Real COM drivers for Windows systems
(Virtual Serial Port Utility) and TTY drivers for Linux systems.
TCP Server & Client
TCP (Transmission Control Protocol) provides a reliable transport layer for
transmitting serial data over the TCP protocol via socket programming.
TCP Server
In TCP Server mode, data transmission is bidirectional. In this mode, the host
computer initiates contact with the Secure Device Server and requests a
connection to its serial port.
Once the connection is established, the host receives data from the serial
device. From this point on, data can be transmitted between the host and the
device in both directions. SSL data encryption is supported in this operating
mode.
The Secure Device Server supports simultaneous connections from up to 16
host computers in this mode, allowing multiple computers to communicate
with the serial device at the same time.
Secure Device Server User Manual
58
Note: Be sure that the Base socket entry specified on the General Settings
page corresponds to the port that the device listens on. 5001 is the
Secure Device Server’s default setting. (See General, page 34.)
TCP Client
In TCP Client mode, when serial data comes into the serial port, the Secure
Device Server initiates contact with the host computer and begins sending
serial data to the to the host. The Secure Device Server can send data to up to
16 host computers simultaneously, and supports SSL data encryption in this
operating mode.
For configuring the serial port’s operating mode, see Operating Mode, page
27.
Serial Tunneling Server & Client
Serial Tunneling involves establishing a direct connection between two Secure
Device Servers over Ethernet, working in a Client-Server relationship. One
unit is designated as the Serial Tunneling Client, while the other designated as
the Serial Tunneling Server.
Note: In this configuration, it doesn’t matter which is designated as the Client
and/or Server.
The COM port of one of the two units connects to the COM port of a computer,
while the COM port of the other unit connects to the serial device to be
accessed.
The two units then communicate with each other via their IP and port
addresses, and supports SSL data encryption. The port address is set by the
Base socket entry on the General Settings page. See General, page 34, for
details.
UDP Mode
UDP (User Datagram Protocol) Mode is faster and more efficient at
communications than TCP. In UDP mode, communications are bilateral. A
Chapter 6. Port Operating Modes
59
serial device can send data to, and receive data from, up to 16 host computers
via the Secure Device Server’s COM port.
Because it doesn’t perform error checking in the thorough way that TCP does,
UDP is more suitable for real time applications (such as message display) than
the slower TCP, which is optimized for data accuracy.
Console Management
Console Management allows users to establish Telnet and/or SSH sessions to
the Secure Device Server for managing and controlling the serial devices
connected. Users can log in using Java SNViwer application via Telnet or SSH,
or remotely via Telnet, SSH, or PuTTY.
Note: 1. Be sure that the Base socket entry specified on the General Settings
page corresponds to the port that the device listens on. 5001 is the
Secure Device Server’s default setting (see General, page 34).
2. In this mode, the Secure Device Server can also be connected to a
Cisco Network Switch using the Cisco console cable (DB-9 to RJ-
45).
Console Management Direct
When the Direct option under Console Management mode is enabled, users
can establish a Telnet or SSH session directly from a PC to a serial device
connected to the Secure Device Server without requiring to log in via a web
browser. Users can log in to a connected serial device using Telnet, SSH, or
PuTTY directly from a PC.
For configuring the serial port’s operating mode, see Operating Mode, page
27.
61
Chapter 7
Port Access
Overview
Upon login of the Secure Device Server’s web interface, the Serial Ports page
appears. Use the buttons, described below, to access and control the device’s
serial COM ports.
Note: Buttons are only active for the functions that the user is authorized to
perform.
Button Function
Edits the serial port’s settings. See Editing Serial Ports, page 24.
Opens a Telnet session with the Secure Device Server using
SNViewer to access either its configuration menu, or a serial device
connect to its COM port. See Telnet / SSH, page 62, for details.
Opens an SSH session with the Secure Device Server using
SNViewer to access either its configuration menu, or a serial device
connect to its COM port. See Telnet / SSH, page 62, for details.
Downloads the port activity logs (up to 128 KB) of the serial port as a
log.txt file. See Port Buffering, page 26.
Secure Device Server User Manual
62
Telnet / SSH
To access the Secure Device Server’s configuration menu, or a serial device
connected to its COM port via Telnet or SSH, click the Telnet or SSH button
on the Serial Ports page. A Java application — SNViewer — appears and opens
a Telnet / SSH session, as exemplified below.
Note: 1. JRE 8 must be installed to run SNViewer.
2. In order for the Telnet / SSH buttons to appear, the Secure Device
Server’s COM port must be set to Console Management mode (see
Operating Mode, page 27).
SNViewer
The SNViewer is a Java application used to access serial devices connected to
the Secure Device Server on the web via Telnet / SSH protocol.
Moving the mouse cursor over the SNViewer brings up its control panel, which
consists of three rows: an icon row and two text rows.
By default, the upper text row shows the width and height of the window.
As the mouse cursor moves over the icons in the control panel, the
information in the upper text row changes to indicate the icon’s function.
The lower row shows the IP address and port of the device you are
accessing, along with the current connection status.
Chapter 7. Port Access
63
Control Panel Functions
The Control Panel functions are described in the table below and the sections
that follow.
Icon Function
Pins / unpins the Control Panel to appear Always On Top or Auto
Hide mode.
Copies the selected text on the screen.
Copies all text displayed on the screen.
Pastes the copied text.
Toggles Logging on / Logging off. This starts a log file of characters
sent from the serial device to the SNViewer. You must first create
and import a text-based log file (see Logs, page 47).
Browses for data files to import (see Data Import, page 64).
Changes the page encoding (see Encode, page 64).
Resets the terminal to its default settings.
Changes the font, color and other display settings of the SNViewer
(see Terminal Settings, page 64).
Adjusts the width of the SNViewer window.
Exits the viewer.
Secure Device Server User Manual
64
Data Import
The Data Import option opens a standard browse menu to import data files, as
shown below.
Encode
The Encode option selects the type of encoding to be used, as illustrated below.
Terminal Settings
The Terminal Settings option allows users to change the display parameters
and settings of the terminal session, as described below.
Chapter 7. Port Access
65
Category Description
Font Configures the SNViewer’s font settings, including the font type, size,
and style. An example of the setting is displayed on the right.
Color Changes the Foreground, Background, Cursor Text, and/or Cursor
colors.
Use the HSL, Swatches, and HSV tabs to make detailed adjustments
and select the colors.
Below the tab is a Preview of how the color changes will look like.
Click OK to save the changes; Cancel to remove the changes and
exit; or Reset to revert to default color settings.
Size The size of the window determines the amount of information
displayed. Change the SNViewer’s window size by configuring the
Column and Row sizes.
Others Use this section to set the following:
Implicit CR in every LF: Checking this box adds an extra Carriage
Return when the [Enter] key is used, so the cursor returns aligned
on the left margin. Use this function if the text is not lining up on
the left margin after you hit [Enter].
Backspace is Delete Key
Local echo: An echo is a response from the serial device of
character(s) that have been inputted.
Auto: Characters that are typed in are echoed but not
displayed on the screen.
Force On: Characters that are typed in are echoed and
displayed on the screen as they are entered. Passwords are
displayed when enabled.
Force Off: Characters are not echoed from the serial device.
Buffer Size: This is the maximum size of the Log file.
Log File: The log file generates a log of characters sent from the
connected serial device to the SNViewer. The log must first be
created as a text file using an external editor such as Note or
Microsoft Word, then opened here. Next, you must enable Logging
on from the SNViewer Control Panel (see Control Panel
Functions, page 63).
Secure Device Server User Manual
66
This Page Intentionally Left Blank
67
Chapter 8
Remote Terminal Operation
Overview
The Secure Device Server can be accessed via remote terminal sessions via
several methods, including Telnet, SSH, or PuTTY, as described in the sections
that follow.
Terminal Login
Aside from using a web browser, users can also log in remotely using a text-
based terminal application, such as Telnet, SSH, or PuTTY.
Telnet Login
Start a terminal (command line) session and type the IP address of the Secure
Device Server in the following format:
telnet [IP Address]
Press [Enter]
Note: The default telnet port is 23. To control a device connected to the
Secure Device Server’s COM port — rather than opening its main
menu — specify the port number as set by the Base socket entry in
General Settings (see General Settings, page 34).For example:
telnet 192.168.0.605001
A login prompt appears:
For first-time login, type the default username — administrator, press
[Enter], then type the default password — password, and press [Enter]
again to log in.
Secure Device Server User Manual
68
SSH Login (Linux)
Start a terminal (command line) session and type the IP address of the Secure
Device Server in the following format:
ssh [username@IP Address]
Press [Enter] then enter the password of the Secure Device Server to log in.
Note: The default SSH port is 22. To control a device connected to the Secure
Device Server’s COM port — rather than opening its main menu —
specify the port number that was sby the Base socket entry in General
Settings (see General Settings, page 34). For example:
ssh
administrator@192.168.0.60-P5001.
Third-party Utility (Windows)
SSH sessions can also be accessed on Windows with the use of third-party
utilities, such as PuTTY — a free implementation of Telnet and SSH for Win32
and Unix platforms. To make an SSH connection via PuTTY, do the following:
1. Under Host Name, enter IP address of the Secure Device Server.
2. Select SSH under Protocol and click Open.
3. Once connected, provide a valid username and password to log in to the
Secure Device Server.
Note: If the login fails, the SSH protocol doesn't allow you to try again.
You must close the PuTTY and start over.
Chapter 8. Remote Terminal Operation
69
Terminal Main Menu
Once logged in, the following text-based main menu appears.
The terminal session main menus contain text-based configurations similar to
that of the web browser previously described, but with a few limitations, such
as unable to perform firmware upgrade and setting backup & restore.
Users can refer to the information provided in the browser version (see Web
Console, page 23) while working through the submenus.
Note: As with the browser version, access to many of these submenus are
restricted to the administrator or users with COM port access
permissions. If you select a submenu that you are not authorized for,
nothing will happen.
Users can access the serial devices connected to the Secure Device Server via
4. Device Access.
Note: To access a connected serial device, the Operating Mode of the serial
port must be set to Console Management (see Operating Mode,
page 27).
To close the terminal session, bring up the Main Menu and press [Q] to log out.
Then close the window.
Secure Device Server User Manual
70
This Page Intentionally Left Blank
71
Chapter 9
Virtual Serial Port Manager
Overview
The Secure Device Server offers a Virtual COM port driver for Windows, Real
TTY driver for Linux, and Fixed TTY driver for OpenServer, Solaris,
FreeBSD, AIX, and Mac.
By running the driver on a PC, devices connected to the Secure Device Server’s
COM ports, appear as if they were directly connected to the COM ports of that
PC.
Note: The Operating Mode of the serial ports must be set as Real COM to be
configured as a virtual port (see Operating Mode, page 27).
Data transmission takes place over the Ethernet between the PC’s virtual COM
port and the devices connected to the Secure Device Server’s COM ports.
Users can download and install the driver corresponding to their PC OS from
the Secure Device Server’s product web page.
Secure Device Server User Manual
72
Real COM Port Management — Virtual Serial Port
Manager
The Virtual Serial Port Manager is a utility that provides a convenient interface
for COM port mapping.
Note: The Virtual Serial Port Manager only supports Windows and Linux with
Kernel 4.15.0-43 and 4.2.0-27. For other versions of Linux systems, see
Real COM Port Management — Linux Commands, page 78.
Start Virtual Serial Port Manager (Start
>
Virtual Port Management Utility
>
Virtual Serial Port Manager). The following dialog box appears.
Utility Interface
The Virtual Serial Port Manager’s interface is laid out as follows:
The menu and button bars allow the automatic enumeration and listing of
devices and ports.
Below the menu and button bars is an area to input the required
information for manually listing devices if the target device doesn’t appear
using the automatic enumeration method.
All devices found through enumeration or manually entered are listed in
the left panel.
All ports found on the device selected are enumerated in the central panel.
The right panel displays any virtual COM port mapping that have been
made.
Chapter 9. Virtual Serial Port Manager
73
Menu and Toolbar
The Virtual Serial Port Manager menu and toolbar consist of the same
functions. Users can either click the menu items or buttons to invoke the
desired function, as described in the table below.
Target Information
The Target Information fields allow users to install (map) ports on an offline
target device, as described below.
Item Action
Enum Targets This function searches and lists all SN devices within the LAN
— these include Secure Device Server, as well as ATEN
Serial Console Servers. The results are shown in the Target
List panel (see Target List, page 74, for details). Beware that
all devices listed in the Target List will be deleted when the
delete function is invoked. Be sure to remove any devices
from the list that you don’t want to delete before invoking the
delete function.
Enum Ports This function lists the existing ports for the target device
currently selected in the Target List. The results are shown in
the Port List panel.
Map After selecting a port from the Port List panel, selecting this
function maps the device’s COM port to a virtual COM port on
the user’s PC.
Unmap After selecting a port from the Mapped Ports list, selecting this
function removes the mapping between the PC and the
device’s COM port.
Field Action
Target IP Address Input the IP address of the target that you want to map COM
ports to.
Base Socket Port The base socket port of the target device. For Real COM port
operation, the default base socket port is 5200.
Target Name The name of the target. If it is different from the target’s real
name, will be replaced by the real one. Note that the name is
not related to the mapping / unmapping process. Only the IP
address, socket port and target type are relevant.
Target Type The type of target to be mapped. SN3001 / SN3002 and ATEN
Serial Console Servers are valid target types.
Note: SN3001 includes SN3001P, and SN3002 includes
SN3002P.
Add Target Creates an entry in the Target List based on the above
information.
Delete Target Remove the currently selected target from the Target List.
Secure Device Server User Manual
74
Target List
The left panel displays all the devices that were found with the Enumeration
function, as well as any devices that were manually added with the Target
Information fields.
Note: Double-clicking an item in the list invokes the same function as
selecting Enum Ports, which displays the numbers and working modes
of the selected target’s ports in the Port List column.
If a device was automatically listed as a result of the Enumeration
procedure, the icon to its left is drawn with green dots and lines to show
that the target is online and ready to be mapped.
If a device was added to the list manually and is offline, the icon to its left
is drawn with black dots and lines. Double-clicking a manually added item
shall display its information in the Port List, but the working mode
information is not accurate and we must assume that all the device’s ports
are in Real COM mode. See Operating Mode, page 27, for details about
port modes.
If the target is offline or is online but does not respond within 2 seconds of
asking to enumerate its ports, the working mode information is not
accurate and we must assume that all the device’s ports are in Real COM
mode. See Operating Mode, page 27, for details about port modes.
Chapter 9. Virtual Serial Port Manager
75
Port List
This list displays the port information of the selected target (only one target can
be selected at a time).
The left column lists the target’s port number, the second column shows
the COM port it is mapped to (if any), the third column shows its working
mode, and the right column shows its status.
Note: The working mode refers to the operating mode that the serial port
is set as. See Operating Mode, page 27, for details.
Double-clicking a port in the Port List brings up the Port Mapping dialog
box. See Port Mapping, page 76 for mapping details.
Note: The Port Mapping dialog box can also be invoked either by clicking
MapTo… on the toolbar or selecting MapTo… from the menu.
Secure Device Server User Manual
76
Port Mapping and Unmapping
Port Mapping
To map a virtual COM port:
1. Double-click your Target item in the Port List to brings up the Port
Mapping dialog box:
2. From the drop-down list, select the desired COM port to map the Target
port to.
3. Click OK.
Note: If a warning dialog box comes up, you can safely ignore it. Click
Continue Anyway to complete the operation
Mapped COM Port
The far-right panel on the Virtual Port Management displays the mapped COM
port. The entry is generated as soon as the application starts, and is updated
whenever the mapped COM port configuration changes as a result of
installations and removals.
Up to 256 ports can be mapped on a Windows system.
Chapter 9. Virtual Serial Port Manager
77
Port Unmapping
To unmap a virtual COM port, do the following:
1. Select the mapped COM port (in the far-right panel) to bring up the Port
Unmapping dialog box:
Note: If the dialog box doesn’t come up, either click Unmap… on the
button bar, or select Unmap… from the menu.
2. Click OK to complete the operation.
Secure Device Server User Manual
78
Real COM Port Management — Linux Commands
Mapping / Unmapping Virtual Ports
To map or unmap virtual ports, do the following:
1. As root, go to the /usr/lib/AtenVPort directory.
2. Issue the following command:
/AtenVPMapping
The process can run in either Interactive mode or Fast mode. With Interactive
mode, users are not required to specify any parameters on the command line.
They make mapping/unmapping choices based on questions generated as the
program runs.
With Fast mode, users must specify parameters on the command line to
indicate their mapping/unmapping choices — as shown in the following
examples:
1. Mapping (input should be all within one line):
./AtenVPMapping map(1) PCPort(0-255) TargetIP(a.b.c.d)
TargetPort(1-48) NumberofMapping(1-48)
2. Unmapping (input should be all within one line):
./AtenVPMapping unmap(0) PCPort(0-255) NumberofUnMapping(1-48)
Up to 256 ports can be mapped on a Linux system.
Virtual Port Naming Rules
All of the ATEN SN virtual ports under Linux have the prefix ttya.
Mapped virtual ports can be found in the /dev dir. They all have a prefix of ttya
(ttya000, ttya001, etc.). The range is from ttya000 – ttya255.
79
Appendix
Safety Instructions
General
Read all of these instructions. Save them for future reference.
This product is for indoor use only.
Follow all warnings and instructions marked on the device.
Do not place the device on any unstable surface (cart, stand, table, etc.). If
the device falls, serious damage will result.
Do not use the device near water.
Do not place the device near, or over, radiators or heat registers.
The device cabinet is provided with slots and openings to allow for
adequate ventilation. To ensure reliable operation, and to protect against
overheating, these openings must never be blocked or covered.
The device should never be placed on a soft surface (bed, sofa, rug, etc.) as
this will block its ventilation openings. Likewise, the device should not be
placed in a built in enclosure unless adequate ventilation has been provided.
Never spill liquid of any kind on the device.
Unplug the device from the wall outlet before cleaning. Do not use liquid
or aerosol cleaners. Use a damp cloth for cleaning.
The device should be operated from the type of power source indicated on
the marking label. If you are not sure of the type of power available,
consult your dealer or local power company.
To prevent damage to your installation it is important that all devices are
properly grounded.
Do not allow anything to rest on the power cord or cables. Route the
power cord and cables so that they cannot be stepped on or tripped over.
Position system cables and power cables carefully; Be sure that nothing
rests on any cables.
Never push objects of any kind into or through cabinet slots. They may
touch dangerous voltage points or short out parts resulting in a risk of fire
or electrical shock.
Do not attempt to service the device yourself. Refer all servicing to
qualified service personnel.
Secure Device Server User Manual
80
When connecting or disconnecting power to hot-pluggable power
supplies, follow the guidelines below:
Install the power supply before connecting the power cable to the
power supply.
Unplug the power cable before removing the power supply.
If the system has multiple sources of power, disconnecting power from
the system by unplugging all power cables from the power supplies.
If the following conditions occur, unplug the device from the wall outlet
and bring it to qualified service personnel for repair.
The power cord or plug has become damaged or frayed.
Liquid has been spilled into the device.
The device has been exposed to rain or water.
The device has been dropped, or the cabinet has been damaged.
The device exhibits a distinct change in performance, indicating a need
for service.
The device does not operate normally when the operating instructions
are followed.
Only adjust those controls that are covered in the operating instructions.
Improper adjustment of other controls may result in damage that will
require extensive work by a qualified technician to repair.
The socket-outlet shall be installed near the equipment and shall be easily
accessible.
Appendix
81
DC Power
The system relies on the protective devices in the building installation for
protection against short-circuit, overcurrent, and earth (grounding) fault.
Ensure that the protective devices in the building installation are properly
rated to protect the system, and that they comply with national and local
codes.
Ensure that there is a readily accessible disconnect device incorporated in
the building's installation wiring.
A separate protective earthing terminal is provided on this product and
shall be permanently connected to earth.
For the DC supply circuit, select a DC supply cable that is certified by UL,
AWM VW-1 Style 1015, minimum 16 AWG, minimum 105º C, minimum
300 V.
CAUTION: This equipment is designed to permit the connection of
the earthed conductor of the DC supply circuit to the earthing conductor at
the equipment. If this connection is made, all of the following conditions
must be met:
This equipment shall be connected directly to the DC supply system
earthing electrode conductor or to a bonding jumper from an earthing
terminal bar or bus to which the DC supply system earthing electrode
conductor is connected.
This equipment shall be located in the same immediate area (such as
adjacent cabinets) as any other equipment that has a connection
between the earthed conductor of the same DC supply circuit and the
earthing conductor, and also the point of earthing of the DC system.
The DC system shall not be earthed elsewhere.
The DC supply source is to be located within the same premises as this
equipment.
Switching or disconnecting devices shall not be in the earthed circuit
conductor between the DC source and the point of connection of the
earthing electrode conductor.
WARNING: This unit is intended for installation in restricted access
areas. A restricted access area (server room, data center, etc.) is where
access can only be gained by service personnel through the use of a special
tool, lock and key, or other means of security, and is controlled by the
authority responsible for the location.
Secure Device Server User Manual
82
Rack Mounting
Before working on the rack, make sure that the stabilizers are secured to
the rack, extended to the floor, and that the full weight of the rack rests on
the floor. Install front and side stabilizers on a single rack or front
stabilizers for joined multiple racks before working on the rack.
Always load the rack from the bottom up, and load the heaviest item in the
rack first.
Make sure that the rack is level and stable before extending a device from
the rack.
Use caution when pressing the device rail release latches and sliding a
device into or out of a rack; the slide rails can pinch your fingers.
After a device is inserted into the rack, carefully extend the rail into a
locking position, and then slide the device into the rack.
Do not overload the AC supply branch circuit that provides power to the
rack. The total rack load should not exceed 80 percent of the branch circuit
rating.
Make sure that all equipment used on the rack – including power strips and
other electrical connectors — is properly grounded.
Ensure that proper airflow is provided to devices in the rack.
Ensure that the operating ambient temperature of the rack environment
does not exceed the maximum ambient temperature specified for the
equipment by the manufacturer
Do not step on or stand on any device when servicing other devices in a
rack.
Appendix
83
Technical Support
International
For online technical support – including troubleshooting, documentation,
and software updates: http://support.aten.com
For telephone support, see Telephone Support, page vi.
North America
When you contact us, please have the following information ready beforehand:
Product model number, serial number, and date of purchase.
Your computer configuration, including operating system, revision level,
expansion cards, and software.
Any error messages displayed at the time the error occurred.
The sequence of operations that led up to the error.
Any other information you feel may be of help.
Email Support support@aten-usa.com
Online
Technical
Support
Troubleshooting
Documentation
Software Updates
http://support.aten.com
Telephone Support 1-888-999-ATEN ext 4988
1-949-428-1111
Secure Device Server User Manual
84
Specifications
Function Specification
Connectors Serial 1 x DB-9 Male (Black)
1 x DB-9 Male (Black; SN3002 / SN3002P only)
Network 1 x RJ-45 Female (Black)
Power PWR1 1 x DC Jack (Balck)
PWR2 1 x 3-pole Terminal (Green)
PWR3 1 x RJ-45 PoE, IEEE 802.3af
(SN3001P / SN3002P only)
Switches Reset 1 x Semi-recessed button
LEDs Power 1 x Green
Status 1 x Yellow Green / Red
Port 1 / Port 2 1 x Green / Orange
1 x Green / Orange (SN3002 / SN3002P only)
10 / 100 Mbps 1 x Green
1 x Orange
Power Input Power Jack 9 V DC
Power Terminal 9 - 48 V DC
PoE 48 V DC (SN3001P / SN3002P only)
Power Consumption
SN3001
DC 9 V : 0.634 W : 3 BTU
DC 48 V : 0.804 W : 4 BTU
SN3002
DC 9 V : 0.769 W : 4 BTU
DC 48 V : 0.939 W : 4 BTU
SN3001P
DC 9 V : 0.805 W : 4 BTU
DC 48 V : 0.975 W : 5 BTU
PoE: 1.22 W : 6 BTU
SN3002P
DC 9 V : 0.94 W : 4 BTU
DC 48 V : 1.11 W : 5 BTU
PoE: 1.39 W : 7 BTU
Appendix
85
Interfaces Serial Standards RS-232
Baud Rate 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800,
7200, 9600, 19200, 38400, 57600, 115200, 230400,
460800, 921600
RS-232 Signals TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Parity None, Even, Odd, Mark, Space
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Flow Control RTS/CTS, DTR/DSR, XON/XOFF, None
Network Standards 10/100BaseTX; Autosensing
Protection 1.5 KV Magnetic Isolation
Protocols ARP, DHCP, DNS, HTTP, HTTPS, ICMP, IP, TCP,
UDP, NTP, PPP, RADIUS, Telnet, SNMP, SNMP
Trap, SMTP, SSH
Standard and Compliance EMC EN55032/35
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 2 kV (Power
Adapter), 1 kV (Terminal Block); Signal: 1 kV
IEC 61000-4-6 CS: 150 kHz to 10 MHz: 3 V/m; 10
kHz to 30 MHz: 3 to 1 V/m; 30 kHz to 80 MHz: 1 V/
m
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
Safety UL 60950-1 and UL 62368-1 standards compliant
RoHS
Environment Operating Temp. 0 – 60
o
C
Storage Temp. -40 – 75
o
C
Humidity 5 – 95% RH, Non-condensing
Physical
Properties
Housing Metal
Weight SN3001 0.20 kg
SN3002 0.21 kg
SN3001P 0.21 kg
SN3002P 0.22 kg
Dimensions (L x W x H) 9.80 x 11.7 x 2.60 cm
Secure Device Server User Manual
86
Clear Login Information
If you are unable to perform an Administrator login (such as due to login
credentials being corrupted or lost) you can clear the login information by
doing the following.
Note: Performing this procedure also reverts all settings back to their factory
default.
1. Power off the Secure Device Server and remove its housing.
2. Use a jumper cap to short the jumper labeled J1 (DEFAULT PASSWORD).
3. Power on the Secure Device Server.
4. When the Status LED flashes, power off the device.
5. Remove the jumper cap from J1.
6. Close the housing and start the device.
After powering on, you can use the default Administrator username and
password to log in, see Logging In, page 19.
You will be prompted to change the password upon your first-time login after
performing this procedure.
Appendix
87
Troubleshooting
Operation problems can be due to a variety of causes. The first step in solving
them is to make sure that all cables are securely attached and seated completely
in their sockets.
In addition, updating the product’s firmware may solve problems that have
been discovered and resolved since the prior version was released. If your
product is not running the latest firmware version, we strongly recommend that
you upgrade. See Firmware Update, page 44, for upgrade details.
Secure Device Server User Manual
88
Limited Warranty
ATEN warrants its hardware in the country of purchase against flaws in
materials and workmanship for a Warranty Period of two [2] years (warranty
period may vary in certain regions/countries) commencing on the date of
original purchase. This warranty period includes the LCD panel of ATEN LCD
KVM switches. Select products are warranted for an additional year (see A+
Warranty for further details). Cables and accessories are not covered by the
Standard Warranty.
What is covered by the Limited Hardware Warranty
ATEN will provide a repair service, without charge, during the Warranty
Period. If a product is detective, ATEN will, at its discretion, have the option
to (1) repair said product with new or repaired components, or (2) replace the
entire product with an identical product or with a similar product which fulfills
the same function as the defective product. Replaced products assume the
warranty of the original product for the remaining period or a period of 90 days,
whichever is longer. When the products or components are replaced, the
replacing articles shall become customer property and the replaced articles
shall become the property of ATEN.
To learn more about our warranty policies, please visit our website:
http://www.aten.com/global/en/legal/policies/warranty-policy/
Copyright © 2021 ATEN® International Co., Ltd.
Released: 2021-04-21
ATEN and the ATEN logo are registered trademarks of ATEN International Co., Ltd. All rights reserved. All
other brand names and trademarks are the registered property of their respective owners.