Chief FMSWA User Manual
Displayed below is the user manual for FMSWA by Chief which is a product in the Monitor Mount Accessories category. This manual has pages.
Related Manuals
INSTALLATION INSTRUCTIONS
FMSWA
FMSWM
Fusion Modular Wall-Mounting Uprights
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
FMSWM / FMSWA
FMSWM / FMSWA Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively “Milestone”), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
Snaptoggle® is a registered trademark of Mechanical Plastics
Corp.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all mounting systems /
accessories are properly assembled and installed using the
instructions provided.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to mounting system does not
exceed the weight capacity listed in Table 1.
Table 1: Weight Capacities
IMPORTANT ! : The FMSWM/FMSWA is designed to be
mounted to a:
• bare 8" thick solid concrete wall;
• 3/4" CDX plywood-backed, 2" x 4" 25 ga minimum
steel stud wall covered with 1/2" or 5/8" drywall;
• 2" x 4" 25 ga minimum steel stud wall covered with
1/2" or 5/8" drywall; or
• 2" x 4" wood stud (16" on-center) wall covered with
drywall having a maximum thickness of 5/8".
--SAVE THESE INSTRUCTIONS--
MODEL Maximum Weight Allowed
FMSWM /
FMSWA
200 lbs (90.7 kg)
[16" on-center wood studs, or concrete
installations]
125 lbs (56.7 kg)
[16" on-center steel or wood studs with 3/4"
plywood overlay]
75 lbs (34.0 kg)
[16" on-center steel studs]
Installation Instructions FMSWM / FMSWA
3
DIMENSIONS
15.25
387.4
0.63
15.9
7.00
177.8
0.34
8.7
C/L OF
EXTRUSION
HEIGHT ADJUST
SCREW
1.00
25.4
DEPTH ADJUST
2.00
50.8
HEIGHT ADJUST
1.00
25.4
MAXIMUM
DEPTH
2.87
72.9
DISTANCE TO
BACK OF
EXTRUSION
SHOWN WITH HEIGHT ADJUST
AT CENTE R
MINIMUM
DEPTH
DIMENSIONS: INCHES
FMSWM
[MILLIMETERS]
15.25
387.4
0.63
15.9
14.00
355.6
MAXIMUM
DEPTH
2.87
72.9
DISTANCE TO
BACK OF
EXTRUSION
MINIMUM
DEPTH
SHOWN WITH HEIGHT
ADJUST AT CENTER
FMSWA
DIMENSIONS: INCHES
[MILLIMETERS]
FMSWM / FMSWA Installation Instructions
4
LEGEND
TOOLS REQUIRED FOR INSTALLATION
PARTS
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
7/32" - wood
#2
1/2"
3/8" - concrete
}
1/2" - 1/4-20" anchor
D (4)
5/16 x 1/2" E (2)
5/16 x 2-3/4"
F (2)
UX10x60R
G (2)
5/16"
[Slotted washer]
A (1)
[FMSWM - B (1)
[FMSWA - C (1)
[Height adjust
plate]
Wall Attachment Hardware Kit
Outside wall upright] Center wall upright]
Hardware required - not included*
(for steel stud walls)
Installing BETWEEN steel studs into 3/4"
CDX plywood (covered in 1/2" or 5/8"
drywall)
• 1/4-20 BB Snaptoggle® anchor** (Qty 2)
Installing into 3/4" CDX plywood (covered
in 1/2" or 5/8" drywall) AND steel stud
• 1/4-20 BB Snaptoggle® anchor** (Qty 2)
Installing into steel stud covered with 1/2"
minimum thickness drywall
•1/4-20 BB Snaptoggle® anchor** (Qty 2)
* Installer may also purchase Kit FCAT1,
which includes:
• 4--Snaptoggler BB
• 4--1/4-20 x 2-1/2" Grade 5 bolts
•4--1/4" Grade 2 flat washers
** Use, at a minimum, a 2-1/2" long Grade 5
screw with each anchor.
Installation Instructions FMSWM / FMSWA
5
INSTALLATION
NOTE: The FMSWM outside wall uprights (A) ship assembled
to allow height adjustment from the bottom. The
uprights may be changed to allow height adjustment
from above the menu boards. See following
instructions for changing the wall uprights.
If leaving wall uprights with height adjustment at the
bottom, proceed to ATTACH WALL UPRIGHTS
section.
Adjust Wall Uprights
If the installation requires height adjustment from above the
menu boards, adjust the wall uprights (A) BEFORE attaching
uprights to the wall.
IMPORTANT ! : Keep all hardware that is removed
during this adjustment process.
1. Remove flanged nut and washer from top of wall upright. (A)
(See Figure 1)
2. Remove hex head screw from bottom of wall upright.
Figure 1
3. Remove one button head screw, spring washer and flat
washer from four locations on side of wall upright. (See
Figure 2)
Figure 2
4. Remove wall upright assembly from outer bracket, while
removing one shoulder washer and one steel washer from
between outer bracket and wall upright assembly in four
locations. (See Figure 3)
Figure 3
5. Remove four button head screws and nuts, and one small
metal plate from lower side within wall upright. (See Figure 4)
6. Reinstall metal plate at top of wall upright using same
hardware removed in Step 5. (See Figure 4)
Figure 4
1
2
(A)
3
Spring
washer
Flat
washer
Steel
Shoulder
Outer bracket
Steel and shoulder
washers removed
from four locations
washer
washer
Remove
steel and
shoulder washers
4
x 4
5
6
Re-install
plate
FMSWM / FMSWA Installation Instructions
6
7. Rotate wall assembly so that height-adjust screw is at top of
wall upright assembly. (See Figure 5)
8. Insert one shoulder washer and one steel washer between
outer bracket and wall upright assembly in four locations.
9. Insert wall upright assembly into outer bracket by placing
wall upright assembly onto threaded pem at top of outer
bracket.
Figure 5
10. Fasten one button head screw, spring washer and flat
washer into four locations on sides of wall upright.
11. Fasten hex head screw into bottom of wall upright.
12. Replace and tighten flanged nut and washer onto threaded
pem at top of wall upright. (See Figure 5)
Attach Wall Uprights
1. Use the FMSWM outside wall upright (A) or FMSWA center
wall upright (B) as a model to mark upper and lower pilot
hole placement for 2 outside wall uprights (and center wall
upright if required) following wall placement information in
Modular Systems installation instructions.
Figure 6
IMPORTANT ! : See Parts drawing, Table 2 and
Installing to Wood Stud Walls section, Installing to
Concrete Walls section, or Installing to Steel Stud
Walls section for details on installing wall brackets.
Table 2: Fastener Information
7
9
9
Height-adjust
screw
Threaded pem
8
Shoulder washer
Steel washer
Outer bracket
10
x 4
Spring
washer
Flat
washer
12
11
WALL
TYPE
PILOT
HOLE
FASTENERS (see PARTS drawing)
Wood stud
(2" x 4")
7/32" x 3"
5/16 x 2-3/4" hex head lag (E) &
5/16" slotted washer (G). Fasteners
placed at stud locations.
Concrete 3/8" x 3" 5/16 x 2-3/4" hex head lag (E) &
Fischer UX10x60 anchor (F).
Steel stud
1/2"
1/2"
1/2"
-- Installing BETWEEN steel studs
into 3/4" CDX plywood (covered in
1/2" or 5/8" drywall)
1/4-20 BB Snaptoggle anchor* (2 ea)
--
Installing into 3/4" CDX plywood
(covered in 1/2" or 5/8" drywall) AND
steel stud
1/4-20 BB Snaptoggle anchor
*
(2 ea)
-- Installing into steel stud covered
with 1/2" or 5/8" drywall
1/4-20 BB Snaptoggle anchor
*
(2 ea)
*
Use, at a minimum, a 2-1/2" long
Grade 5 screw with each anchor.
NOTE: Installer may also purchase
Kit FCAT1 (1/4-20 Grade 5 Toggler
Kit)
1
(A)
(B)
Installation Instructions FMSWM / FMSWA
7
Installing to Wood Stud Walls
1. Drill one 7/32" (5.5mm) pilot hole in stud at upper mounting
slot. (See Figure 7)
2. Partially install one 5/16 x 2-3/4" flanged lag bolt (E) into
pilot hole but do not tighten to wall.
3. Hang outside wall upright (A) [or center wall upright (B)]
aligning upper mounting slot over lag bolt and level upright.
4. Place one slotted washer (G) over flanged lag bolt. (See
Figure 7)
5. Tighten lag bolt to secure wall upright (A or B) to wall at
upper mounting slot. (See Figure 7)
Figure 7
6. Mark the attachment point for the lower mounting slot,
making sure the attachment point is located on the stud.
(See Figure 7)
7. Drill 7/32" (5.5mm) pilot hole at marking for lower mounting
hole. (See Figure 7)
8. Use one 5/16 x 2-3/4" flanged lag bolt (E) and one 5/16"
slotted washer (G) to attach each wall upright to the wall
through the lower mounting hole. (See Figure 7)
9. Repeat Steps 1 through 8 for remaining wall upright(s).
10. Adjust depth of wall uprights, if necessary, so that the face
of the wall uprights are all in the same plane across the
width of wall upright installation: (See Figure 7)
• Loosen button head screws (4 places)
• Adjust depth along depth-adjust slots.
• Tighten button head screws.
IMPORTANT ! : Be sure to securely tighten depth-adjust
screws after adjustment.
11. Proceed to Mounting Rails section.
Installing to Concrete Walls
1. Drill one 3/8" x 3-1/2" (9.5mm x 88.9mm) pilot hole at each
marking. (See Figure 8)
2. Install one anchor (F) into each pilot hole using a hammer,
making sure that the anchor is flush with the wall.
3. Partially install one 5/16 x 2-3/4" flanged lag bolt (E) into
pilot hole but do not tighten to wall.
4. Hang outside wall upright (A) [or center wall upright (B)]
aligning upper mounting slot over lag bolt and level upright.
5. Place one slotted washer (G) over each flanged lag bolt.
(See Figure 8)
6. Tighten lag bolt to secure wall upright (A or B) to wall at
upper mounting slot.
Figure 8
7. Mark the attachment point for the lower mounting slot. (See
Figure 8)
8. Drill 3/8" x 3-1/2" (9.5mm x 88.9mm) pilot holes at marking
for lower mounting hole. (See Figure 8)
9. Install an anchor (F) into each pilot hole using a hammer,
making sure that the anchor is flush with the wall.
10. Use one 5/16 x 2-3/4" flanged lag bolt (E) and one 5/16"
slotted washer (G) to attach the wall upright to the wall
through the lower mounting hole. (See Figure 8)
11. Repeat Steps 1 through 10 for remaining wall upright(s).
12. Adjust depth of wall uprights, if necessary, so that the face
of the wall uprights are all in the same plane across the
width of wall upright installation: (See Figure 8)
• Loosen button head screws (4 places)
• Adjust depth along depth-adjust slots.
• Tighten button head screws.
IMPORTANT ! : Be sure to securely tighten depth-adjust
screws after adjustment.
13. Proceed to Mounting Rails section.
(G)
4
(E) x 2
5
(A)
8
81
7
6
Depth-adjust
screws x 4
10
2
(F) x 2
1
8
9
(E) x 2
6
10
(A)
7
(G)
Depth-adjust
screws x 4
12
FMSWM / FMSWA Installation Instructions
8
Installing to Steel Stud Walls
1.
Installing BETWEEN steel studs into 3/4" CDX plywood (covered in 1/2" or 5/8" drywall)
:
Use two 1/4-20 BB Snaptoggle
anchors with two minimum 2-1/2" long, minimum Grade 5 screws through wall upright into plywood. (Hardware not included.) (See
Figure 9)
2. Installing into CDX plywood (covered in 1/2" or 5/8" drywall) AND steel stud: Use two 1/4-20 BB Snaptoggle anchors with
two minimum 2-1/2" long, minimum Grade 5 screws through wall upright and into plywood and steel stud. (Hardware not
included.) (See Figure 9)
3. Installing into steel stud (covered in 1/2" or 5/8" drywall): Use two 1/4-20 BB Snaptoggle anchors with two minimum 2-1/2"
long, minimum Grade 5 screws through wall upright and into drywall and steel stud. (Hardware not included.) (See Figure 9)
Figure 9
FRONT
There must be a minimum of
1-7/8" (48mm) clearance
inside wall
16" or 24" (on center) Studs
If back side of wall is unfinished, drywall must
5/8" maximum
drywall thickness
(Drywall only on back of stud)
3/4" CDX Plywood
3/4" minimum thickness
CDX plywood covered
with drywall having
maximum thickness of 5/8"
1/2" or 5/8"
drywall thickness
(Drywall on both sides of stud)
be installed to a minimum of one stud left and
right of the stud(s) being used to install the
mount. Drywall must be secured to studs with
screws a maximum of 12" (305mm) apart
down center of stud.
Steel Stud with
Drywall only
Steel Stud with
Plywood and Drywall
Steel Stud (2 x 4 / 25ga minimum)
Stud type and structural strength must conform to the North American Specification for the
Design of Cold-Formed Steel Structural Members. [362 S 125 18, C-Shaped, S-Stud Section]
Installation Instructions FMSWM / FMSWA
9
Installing in Steel Stud or in Wood Stud Walls
Between Studs
IMPORTANT ! : See Site Requirements section before
proceeding with Steel Studs installation to ensure installation
site meets requirements! The drywall must have a minimum
thickness of 1/2"!
1. Drill one 1/2" x 1" hole at marked location on wall. (See
Figure 10)
Figure 10
2. Hold metal channel on
Toggler® 1/4-20 Snap-Toggle
(not
included) flat alongside plastic straps and slide channel
through hole. (See Figure 11)
Figure 11
3. Holding plastic straps on anchor, pull anchor away from wall
until channel rests flush behind wall making sure anchor
channel is positioned vertically on steel stud (if present).
(See Figure 12)
4. Slide plastic cap on anchor towards wall until flange of cap
is flush with wall. (See Figure 12)
Figure 12
5. Snap off plastic straps on anchor at wall by pushing side to
side, snapping off straps level with flange of plastic cap.
(See Figure 13)
Figure 13
6. Place wall bracket over anchor and align mounting hole in
wall bracket with hole in anchor. (See Figure 14)
7. Insert minimum Grade 5 minimum 2-1/2" long screw (not
included) through Grade 2 or better 1/4" washer (not
included), corresponding mounting hole on wall bracket and
into Snap-Toggle (not included) and tighten until flush against
mount. DO NOT over tighten! (See Figure 14)
Figure 14
8. Level wall bracket using attached bubble level.
9. Make any necessary corrections to remaining mounting
hole marking(s).
10. Repeat Steps 2 through 8 for remaining mounting hole(s).
11. Adjust depth of wall uprights, if necessary, so that the face
of the wall uprights are all in the same plane across the
width of wall upright installation: (See Figure 10)
• Loosen button head screws (4 places)
• Adjust depth along depth-adjust slots.
• Tighten button head screws.
IMPORTANT ! : Be sure to securely tighten depth-adjust
screws after adjustment.
12. Proceed to Mounting Rails section.
1
x 2
Depth-adjust
screws x 4
11
x 2
Drywall
Plastic Straps
2
anchor x 2
Plastic Cap
Drywall
Anchor Metal Channel (side view)
4
Steel Stud
3
(if present)
Plastic Straps
Drywall
Anchor Metal Channel
Plastic Cap
5
Steel Stud (if present)
(side view)
Drywall
Anchor Metal Channel
(G)
x 4
7
Steel Stud (if present)
x 4
(side view)
FMSWM / FMSWA Installation Instructions
10
Mounting Rails
1. Slide height adjust plates (C) into open end of mounting rail.
(See Figure 15)
Figure 15
2. Hook height adjust plates (C) over wall uprights (A or B).
(See Figure 16)
NOTE: Hook all height adjust plates (C) over wall uprights (A
or B), and approximately center mounting rail over the
span of the wall uprights (A or B) BEFORE proceeding
to next step.
3. Fasten mounting rail to wall uprights using four 5/16 x 1/2"
Phillips flat head screws (D) through height adjust plate (C)
and into wall uprights (A or B) and tighten all screws. (See
Figure 16)
Figure 16
4. Attach one remaining end cap following FMSECAP
installation instructions.
Figure 17
Adjust and Level Mounting Rail
1. Adjust the height of the mounting rail via the wall upright, as
necessary, to level the mounting rail on the wall. (See
Figure 18)
• Turn the wall upright height-adjust screw clockwise
(viewed from bottom) to raise the mounting rail.
• Turn the wall upright height-adjust screw counter-
clockwise (viewed from bottom) to lower the mounting
rail.
2. Adjust the depth of the mounting rail via the wall upright, as
necessary, to make the mounting rail distance from the wall
consistent.
• Loosen depth-adjust button head screws, and move
mounting rail away or toward the wall, as necessary.
• Tighten depth-adjust button head screws.
IMPORTANT ! : Be sure to securely tighten depth-adjust
screws after adjustment.
Figure 18
1
(C)
Mounting rail
(front view of rail)
3
(D) x 4
2
2
(C)
(A)
(front view of rail)
(back view of rail)
Height-adjust
screw
Depth-adjust
screws x 4
(Front view)
Installation Instructions FMSWM / FMSWA
11
FMSWM / FMSWA Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
Chief, a products division of
Milestone AV Technologies
8800-003031 Rev00
2018 Milestone AV Technologies
www.milestone.com
07/18