Chief LW49UBP User Manual
Displayed below is the user manual for LW49UBP by Chief which is a product in the Signage Display Mounts category. This manual has pages.
Related Manuals
INSTALLATION INSTRUCTIONS
46"/47"/48"/49"/50"/55" Portrait Wall Kiosks
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
LW46/47/48/49/50/55UxP
LW46/47/48/49/50/55UxP Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively “Milestone”), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all mounting systems
are properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this mounting system can result in serious personal injury
or damage to equipment! It is the installer’s responsibility to
make sure the structure to which this mounting system is
attached can support five times the combined weight of all
equipment. Reinforce the structure as required before
installing the mounting system.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the weight of
components attached to swing door does not exceed:
•LW46/47/48UxP Models: 100 lbs (45.4 kg)
Removable storage panel capacity: 5 lbs (2.3 kg);
•LW49/50/55UxP Models: 125 lbs (56.7 kg)
Removable storage panel capacity: 15 lbs (6.8kg).
The hinge-open position is for installation and service only.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this mounting system outdoors.
IMPORTANT ! :
The LW46/47/48/49/50/55UxP portrait wall
kiosks are designed to be mounted to an:
• a bare 8" concrete or 8"x8"x16" concrete block wall; or
• a 2" x 4" wood studs (16" on center minimum) wall with
a maximum drywall thickness of 5/8"; or
• a steel stud (16" on center minimum to 24" on center
maximum) wall with a maximum drywall thickness of
5/8".
NOTE: The kiosks have an adjustable depth of 3" to 5".
--SAVE THESE INSTRUCTIONS--
Installation Instructions LW46/47/48/49/50/55UxP
3
DIMENSIONS
46.50
1181.1
27.50
698.5
22.50
571.5
LW46UxP
DIMENSIONS: INCHES
[MILLIMETERS]
46.50
1181.1
27.50
698.5
23.00
584.2
LW47UxP
DIMENSIONS: INCHES
[MILLIMETERS]
LW46/47/48/49/50/55UxP Installation Instructions
4
DIMENSIONS--continued
46.50
1181.1
27.50
698.5
23.50
596.9
LW48UxP
DIMENSIONS: INCHES
[MILLIMETERS]
LW49UxP
DIMENSIONS: INCHES
[MILLIMETERS]
Installation Instructions LW46/47/48/49/50/55UxP
5
DIMENSIONS--continued
LW50UxP
DIMENSIONS: INCHES
[MILLIMETERS]
54.25
1378.0
32.50
825.5
26.84
681.8
55U
DIMENSIONS: INCHES
[MILLIMETERS]
LW55UxP
LW46/47/48/49/50/55UxP Installation Instructions
6
LEGEND
TOOLS REQUIRED FOR INSTALLATION
PARTS
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
7/32" (wood studs)
#2
1/2"
5/32" (security)
5/16" (concrete)
1/2" (steel studs)
[included]
Hardware Bag -
Wall Hardware Hardware Bag - Monitor Interface Hardware
Hardware Bag -
Security/Swap Hardware
AA (8)
5/16 x 2-1/2"
AB (8)
5/16"
AC (4)
1/4-20
SnapToggle
AD (4)
AE (4)
1/4-20 x 1-3/4"
1/4"
BA (4)
M4 x 12mm
BD (4)
M5 x 12mm
BG (4)
M6 x 12mm
BJ (4)
M8 x 12mm
BB (4)
M4 x 25mm
BC (4)
M4 x 50mm
BE (4)
M5 x 25mm
BF (4)
M5 x 50mm
BH (4)
M6 x 25mm
BI (4)
M6 x 50mm
BK (4)
M8 x 25mm
BL (4)
M8 x 50mm
BM (8)
.750x.344x.500"
BO (4)
[universal
washer]
5/32"
(security)
CA (1)
10-24 x 3/8"
CB (4)
10-32 x 3/4"
CC (4)
10-32 x 5/16"
A (1)
[Enclosure assembly]
(LW49UxP shown
as example)
BN (8)
.750x.323x.250"
AF (8)
UX10x60R
CD (4)
10-24 x 2-3/4"
NOTE: Letters match markings on hardware bags
CE (4)
10-24 x 3-1/2"
[not used]
Installation Instructions LW46/47/48/49/50/55UxP
7
ASSEMBLY AND INSTALLATION
Preparing Wall Bracket
1. Remove kiosk from the packaging and place on a flat surface. (See Figure 1)
2. Open so that wall bracket is at a 90° angle from the swing door.
3. Keeping the wall bracket at 90°, slide the wall bracket about 1 inch towards bottom of kiosk until hinge pins clear the hinges, and
move the wall bracket away from the swing door. (See Figure 1)
Figure 1
3
2
Wall bracket
Swing door
NOTE: The kiosks ship with the removable storage panel
already in place in the lower of two mounting positions.
The panel may be removed to add components as
required, and then reinstalled in either location. (See
instructions included with the panel.)
The storage panel latch is spring-loaded. To remove
the panel, squeeze the latch on end tabs and slide the
panel sideways out of the slots on the wall bracket.
Pivot the panel and remove it from the slots on the
opposite side.
Install AV component(s) to the panel using the
hardware and instructions included with the
component(s). Either screws or cable ties may be
used to fasten component(s) to the panel.
To reinstall the panel, slide the panel end without
latches sideways into the slots on one side of the wall
bracket opening. Pivot panel in and slide it sideways
toward the slots on opposite side of the wall bracket
panel opening. The panel will snap into the slots,
securing it to the wall bracket.
IMPORTANT ! : The kiosks ship with the hinge located on
the left side. The hinge location may be switched, if
required, for installation or service. Before beginning the
installation, decide on which side the hinge should be
located and, if you require the kiosk be hinged on the
right side, switch the hinge before completing any other
installation steps. See Switching Hinge Location
section in Appendix.
Locate Mounting Site
WARNING:
IMPROPER INSTALLATION CAN LEAD TO
MOUNT FALLING CAUSING SEVERE PERSONAL INJURY
OR DAMAGE TO EQUIPMENT! It is the installers responsibility
to make certain the structure to which the mount is being
attached is capable of supporting five times the combined
weight of all
components attached to swing door
:
•LW46/47/48UxP Models: 100 lbs (45.4 kg)
Removable storage panel capacity: 5 lbs (2.3 kg).
(See Figure 2)
•LW49/50/55UxP Models: 125 lbs (56.7 kg)
Removable storage panel capacity: 15 lbs (6.8kg).
(See Figure 2)
Figure 2
LW46/47/48UxP
Weight Capacity:
5 lbs (2.3kg)
Weight Capacity:
15 lbs (6.8kg)
Removable storage panels: LW49/50/55UxP
LW46/47/48/49/50/55UxP Installation Instructions
8
Installing Wall Bracket
The LW
46/47/48/
49/50/55UxP wall kiosk mounts are designed
to be mounted to:
• a bare 8" concrete or 8"x8"x16" concrete block wall; or
• a 2" x 4" wood studs (16" on center minimum) wall with
a maximum drywall thickness of 5/8"; or
• a steel stud (16" on center minimum to 24" on center
maximum) wall with a maximum drywall thickness of
5/8".
Table 1: Fastener Information
1. Determine the horizontal center of the wall bracket, and
where it should be located on the wall. (See Figure 3)
• For wood or steel stud walls, use a level and mark the
two uppermost locations over studs for attachment a
minimum of 16" apart and a maximum of 24" apart.
(See Figure 3)
IMPORTANT ! : For maximum stability in a wood or steel
stud wall, mount the hinge side of kiosk as close as
possible to a stud.
• For concrete walls, use a level and mark the two
uppermost locations for attachment as far apart as
possible to provide maximum stability. (See Figure 3) Figure 3
2. Drill one pilot hole (see Table 1 for size) at both locations
marked in Step 1 (See Figure 3) and follow fastener
information (appropriate for wall type) located in Table 1.
IMPORTANT ! : Refer to Fastener Installation Methods
(located in Appendix at end of Installation Instructions)
for details on installing product into various wall types.
WALL
TYPE
PILOT
HOLE
FASTENERS (see PARTS
drawing)
Steel
stud /
Wood
stud
1/2"
7/32"
- 1/4-20 x 1-3/4" Phillips screw (AD)
- 1/4" washer (AE)
- 1/4-20 Snap toggler (AC)
- 5/16 x 2-1/2" hex head lag (AA)
- 5/16" washer (AB)
Concrete 5/16 x 3-1/4" - 5/16 x 2-1/2" hex head lag (AA)
- 5/16" washer (AB)
- Fischer Anchor UX10x60R (AF)
x 2
12
Wall
bracket
Uppermost attachment area
Center wall bracket over desired location on wall
1
Installation Instructions LW46/47/48/49/50/55UxP
9
IMPORTANT ! : Attaching the wall bracket requires a
minimum of 8 wall fasteners. For installation in a wood or
steel stud applications, the snap toggles are required
near the edge of the wall bracket hinge side if the hinge
side is not fastened to a stud. (See Figure 4) and (See
Figure 5)
Figure 4
3. Partially install fasteners into wall, but do not completely
tighten to wall.
4. Hang wall bracket, aligning upper mounting slot clearance
holes over fasteners and adjust side-to-side for proper
location. (See Figure 4)
5. Tighten fasteners to secure wall bracket to wall at upper
mounting slots.
6. Drill six remaining pilot holes (see Table 1 for size) at
attachment locations and follow fastener information
(appropriate for wall type) located in Table 1. (See Figure 4)
7. Tighten six fasteners to secure wall bracket to wall at middle
and lower mounting slots.
8. For Wood and Steel Stud walls: Insert four snap toggles
and related fasteners into hinge side of wall bracket. (See
Figure 5)
IMPORTANT ! : Refer to Fastener Installation Methods
(located in Appendix at end of Installation Instructions)
for details on installing snap toggles and related
fasteners into various wall types.
Figure 5
Attaching Flat Panel
1. Remove and SAVE four Phillips screws, loosen four thumb
nuts and remove hinged frame from swing door. (See
Figure 6)
Figure 6
5
6
x 2
7
[24" on-center attachment
shown as example only]
Clearance
holes
Mounting
slots
8
Insert snap-toggles at arrows
[For Wood and Steel Stud Walls Only]
1
x 4
Thumb
nut
1
Hinged
frame
Outer
frame
LW46/47/48/49/50/55UxP Installation Instructions
10
2. Carefully lay flat panel face down into the depth-adjustable
outer frame. (See Figure 7)
Figure 7
3. Center flat panel on opening within outer frame in both
vertical and horizontal directions.
NOTE: Measuring from inside edges to display edges assists
in centering the display within opening.
WARNING: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Using screws of
improper size may damage your display. Properly sized
screws will easily and completely thread into display
mounting holes. If spacers are required, be sure to use longer
screws of the same diameter.
4. Select screw diameter by examining hardware (BA-BL) and
comparing with mounting holes on flat panel.
5. Select spacers:
• Spacers are NOT required if mounting holes are not
recessed and hinged frame can lay flat against flat
panel.
•Spacers (BM, BN) ARE required if mounting holes are
recessed, or if protrusions prevent hinged frame from
laying flat.
• Spacers may also be used between the hinged frame
and flat panel to create more space for AV
components, or to accommodate thinner flat panels.
(See Depth Adjustment section for further
information.)
6. Select screw length:
• By hand, insert SHORTEST length screw of selected
diameter (BA, BD, BG, or BJ) through universal washer
(BO--if required), hinged frame, spacer (BM, BN--if
required), into flat panel mounting hole. Do NOT thread
screw into hole at this time.
IMPORTANT ! : The M8 screws do NOT require a
washer. Use the universal washer (BO) ONLY with the
M4, M5 or M6 screws.
• Proper screw length requires base of screw head to
protrude above flat washer a distance equal to or
greater than the screw diameter. If screw length is
inadequate, select longer screw. Select shortest screw
which will protrude the required distance.
7. Place hinged frame onto back of flat panel and match the
VESA pattern on flat panel to the hinged frame mounting
slots. Also match the threaded studs in outer frame to the
hooks on the hinged frame. (See Figure 8)
8. Use selected screws (BA-BL), washers (BO--if required),
and spacers (BM, BN--if required), to connect hinged frame
to back of flat panel. (See Figure 8)
Figure 8
NOTE: The outer frame depth may be adjusted between
3" - 5" to make room for a variety of different flat panel
thicknesses. (See Figure 9)
• This outer frame adjustable depth can also be used to
make more space between the back of the flat panel
and wall for AV component storage.
• The 4 Phillips screws removed in Step 1 can be
replaced with four 10-24 x 2-3/4" Phillips screws (CD)
for larger depth adjustments.
Figure 9
2
Depth-adjustable
outer frame
Flat panel
2
NOTE: Use universal washer (BO)
(BO)
(BM and/or BN)
8
(BA-BL) x 4
Outer
frame
ONLY with M4, M5 or
M6 screws.
9
Thumb nuts x 4
10
Previously
(CD) x 4
removed OR
[Flat panel not shown]
Two washers
should remain
between hook
and outside
panel
Installation Instructions LW46/47/48/49/50/55UxP
11
9. Tighten thumb nuts over threaded studs in four locations on
the hinged frame. (See Figure 9)
10. Replace and fasten four Phillips screws which were
removed in Step 1, OR replace the removed screws with
four 10-24 x 2-3/4" Phillips head screws (CD) to allow for a
larger depth adjustment of the outer frame. (See Figure 9)
11. Carefully lift (using two people) the swing door with attached
flat panel.
IMPORTANT ! : Be sure to keep swing door at a 90°
angle to the wall to enable a smooth installation.
12. Keeping the swing door at a 90° angle against the wall, slide
the swing door so that hinge pins are above hinges.
13. Lower swing door to engage hinge pins into hinges. (See
Figure 10)
NOTE: Some resistance is normal when the hinge pins drop
into the hinges.
Figure 10
14. Close swing door and add 10-24 x 3/8" button head security
screw (CA) in hole below latch to lock door. (See Figure 10)
Cabling
1. Cables may be placed through the center slot in the wall
bracket flanges. (See Figure 11)
IMPORTANT ! : Cables should not be placed OVER the
wall bracket flanges. Damage to cables may occur. (See
Figure 12)
Figure 11
Hinge pin
Hinge
13
12
14
(CA x 1)
Swing
door
Swing door must be closed before
Door
open
security screw (CA) is added
Be sure to keep swing door at a 90° angle to
the wall to enable a smooth installation.
Center
slot
1
Do NOT place
cables (dashed
Wall
flanges
Place cables through
center slot in wall
bracket flanges.
lines shown
above) in areas
over wall bracket
flanges as shown.
LW46/47/48/49/50/55UxP Installation Instructions
12
APPENDIX
Switching Hinge Location
1. Remove AND SAVE the hardware on the latch (right) side
of the wall bracket. (See Figure 12)
Figure 12
2. Remove and SAVE two lift-off hinges from hinged side of
wall bracket. (See Figure 13)
3. DISCARD the four fasteners from these hinge parts.
Figure 13
4. Remove and SAVE lift-off hinge and hinge spacer plate
from two locations on swing door. (See Figure 14)
5. DISCARD the four fasteners from these hinge parts.
Figure 14
1
Remove and SAVE
fasteners noted
all parts and
Wall
bracket
2
Remove and
SAVE two hinges
Wall
bracket
Hinge
4
Remove and
SAVE two hinges
and hinge
spacer plates
Spacer
plate
Hinge
Swing door
assembly
Installation Instructions LW46/47/48/49/50/55UxP
13
6. Replace two lift-off hinges and hinge spacer plates onto
opposite side (left) of swing door. (See Figure 15)
7. Fasten in place with four (two each hinge)
NEW
10-32 x 3/4"
button head cap screws (CB). (See Figure 15)
Figure 15
8. Move the lift-off hinges to the right side of the wall bracket.
(See Figure 16)
9. Fasten in place with four (two each hinge)
NEW
10-32 x 5/16"
button head cap screws (CC). (See Figure 16)
Figure 16
Lift-off
hinge
Hinge
spacer
plate
7
(CB) x 4
Wall bracket
9
(CC) x 4
Lift-off
hinge
LW46/47/48/49/50/55UxP Installation Instructions
14
10. Flip and install latch section on left side of wall bracket.
NOTE: Be sure that upper and lower tabs are slid into slots on
wall bracket. (See Figure 17)
11. Fasten in place with two washers and screws removed in
Step 1. (See Figure 17)
12. Re-install small horizontal tab removed from bottom of latch
section in Step 1, by fastening it onto the top of the latch
section. (See Figure 17)
13. Re-install outside latch using fastener removed in Step 1.
(See Figure 17)
14. Re-install inside latch: (See Figure 17)
a. Place spring on top of horizontal tab and compress
spring slightly.
b. Place latch over spring, lining up tabs on latch with slots
in wall bracket.
c. Fasten latch in place with button head cap screw and
washer removed earlier in Step 1.
Figure 17
Ta b s
x 2
11
Insert tab
at top and
into slot
bottom
10
12
Horizontal tab
13
Wall bracket
14a
14b
14c
x 1
Slots
Spring
Installation Instructions LW46/47/48/49/50/55UxP
15
Fastener Installation Methods
IMPORTANT ! : See Table 1 for appropriate hardware
and pilot hole sizes for various wall types.
Wood Stud
1. Use one 5/16" x 2-1/2" hex flange head lag bolt (AA) and
one 5/16" washer (AB) through product and into pilot hole.
(See Figure 18)
2. Repeat for remaining pilot holes.
Figure 18
Concrete
1. Install one UX10x60R anchor (AF) into each pilot hole using
a hammer, making sure that the anchor is flush with the wall.
(See Figure 19)
2. Use one 5/16" x 2-1/2" hex flange head lag bolt (AA) and
one 5/16" washer (AB) through product into each anchor in
wall. (See Figure 19)
3. Repeat for remaining pilot holes.
Figure 19
Steel Stud
IMPORTANT ! : See Site Requirements for Steel Stud
Installation section before proceeding with Steel Studs
installation to ensure installation site meets requirements!
The drywall must have a minimum thickness of 1/2"!
1. Hold metal channel on anchor (AC) flat alongside plastic
straps and slide channel through hole. (See Figure 20)
Figure 20
2. Holding plastic straps on anchor (AC), pull anchor away from
wall until channel rests flush behind wall making sure anchor
channel is positioned vertically on drywall, or steel stud (if
present). (See Figure 21)
3. Slide plastic cap on anchor (AC) towards wall until flange of
cap is flush with wall. (See Figure 21)
Figure 21
4. Snap off plastic straps on anchor at wall by pushing side to
side, snapping off straps level with flange of plastic cap.
(See Figure 22)
Figure 22
1
2
(AA) x 8
(AB) x 8
1
2
(AA)
(AF)
(AB)
(AC)
Drywall
Plastic straps
1
(AC)
Plastic cap
Drywall
Anchor metal channel
3
Steel stud
(side view)
2
(if present)
Plastic straps
Drywall
Anchor metal channel
Plastic cap
4
Steel stud
(side view)
(if present)
LW46/47/48/49/50/55UxP Installation Instructions
16
5. Line up anchor with attachment point.
6. Insert 1/4-20 x 1-3/4" Phillips pan head screw (AD) through
1/4" washer (AE), corresponding mounting hole in wall
bracket and into anchor (AC), and tighten until flush against
wall bracket. DO NOT over tighten! (See Figure 23)
Figure 23
Drywall
Anchor metal channel
(AD) x 4
6
Steel stud
(AE) x 4
(side view)
Wall bracket
(if present)
Site Requirements for Steel Stud Installation
Figure 24
Steel Stud (2 x 4 / 25ga minimum)
FRONT
There must be a minimum of
1-7/8" (48mm) clearance
inside wall
16" or 24" (on center) Studs
If back side of wall is unfinished,
to a minimum of one stud left
Stud type and structural strength must conform to the North American Specification for the
Drywall
**1/2" minimum
Drywall Thickness
(Both Sides of Stud)
**See Warning statement
on page 2!
Design of Cold-Formed Steel Structural Members. [362 S 125 18, C-Shaped, S-Stud Section]
drywall must be installed
and right of the stud(s) being used
to install the mount. Drywall must be
secured to studs with screws a
maximum of 12" (305mm) apart
down center of stud.
Installation Instructions LW46/47/48/49/50/55UxP
17
LW46/47/48/49/50/55UxP Installation Instructions
18
Installation Instructions LW46/47/48/49/50/55UxP
19
LW46/47/48/49/50/55UxP Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
Chief, a products division of
Milestone AV Technologies
8800-003095 Rev00
2018 Milestone AV Technologies
www.milestone.com
10/18