Chief ODAC0304B User Manual
Displayed below is the user manual for ODAC0304B by Chief which is a product in the TV Mount Accessories category. This manual has pages.
Related Manuals
I N S T A L L A T I O N I N S T R U C T I O N S
Outdoor Floor/Ceiling Pipe
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
ODAC SERIES
ODAC SERIES Installation Instructions
2
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
MOMENT: A MOMENT is a product of force and distance. It
is calculated by multiplying the force applied by install drop
length. See Dimensions drawings for further details.
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all accessories are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this accessory can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this accessory is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
accessory.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to mounting system cannot exceed
300 lbs (136 kg).
NOTE: "Moment" ratings have NOT been evaluated by UL.
WARNING: Exceeding the maximum moment can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the mounting system
does not exceed a moment of 2000 ft-lbs. See table below for
specific column specifications.
WARNING: The weight capacity of the ODA mounting
systems may be LIMITED to the lowest weight capacity of
any component located between the ODA330 ceiling plate
and the flat panel display(s).
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Use this mounting system with other outdoor
products only.
WARNING: Always use two people or a mechanical lifting
device to safely lift and position equipment.
WARNING: Due to exposure to outdoor elements such as
strong wind gusts, heavy snow, hail, rain, etc., the mounting
system and its supporting structure must be inspected at
least once per year and immediately following any major
weather event. If evidence of excessive wear, deterioration or
any other unsafe condition is observed this product must be
taken out of service immediately!
NOTE: The ODAC Series columns are intended to be used
with UL listed flat panel floor/ceiling mounts (not
included): OLCM1U, OXCM1U, OLCM2X1U,
OLCB1U, OXCB1U, OLCB2X1U and UL Listed ODA
Floor/Ceiling Plate ODA330 (not included).
--SAVE THESE INSTRUCTIONS--
COLUMN
MODEL
Weight
capacity
Moment
Length (IN)
(ML)
Max
Design
Moment
(FT-LBS)
(MDM)
ODAC0203B 300 lbs (136 kg) 23 min - 36 max 2000
ODAC0304B 300 lbs (136 kg) 33 min - 48 max 2000
ODAC0405B 300 lbs (136 kg) 45 min - 60 max 2000
ODAC0506B 300 lbs (136 kg) 57 min - 72 max 2000
ODAC0708B 300 lbs (136 kg) 81 min - 96 max 2000
Installation Instructions ODAC SERIES
3
DIMENSIONS
TOOLS REQUIRED FOR INSTALLATION
PARTS
1/2"
1/2"
nut driver
A (1)
[ODA Series pipe]
ODAC SERIES Installation Instructions
4
INSTALLATION
IMPORTANT ! : The following procedure assumes that
the UL Listed ODA330 assembly (not included) has been
properly installed following instructions provided with
ODA330 assembly.
1. OPTIONAL: Route cables/conduits through extension
column (A).
2. Insert column (A) in to ODA330 floor/ceiling plate (not
included) until holes align for installation. (See Figure 1)
Figure 1
3. Attach pipe (A) to ODA330 using hardware provided with
ODA330 plate. (See Figure )
IMPORTANT ! : Make sure spacers are properly oriented
to fit around pipe with the lines vertical.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to mounting system cannot exceed
300 lbs (136 kg).
4. Install outdoor ceiling mount and display to pipe (A)
following installation instructions included with mount.
(A)
ODA330
3
x 2
spacers positioned to
fit around pipe
lines vertical
(ODA330
hardware used)
Installation Instructions ODAC SERIES
5
ODAC SERIES Installation Instructions
6
Installation Instructions ODAC SERIES
7
ODAC SERIES Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
Chief, a products division of
Milestone AV Technologies
8800-003019 Rev00
2018 Milestone AV Technologies
www.milestone.com
07/18