Chief PAC527LFCW User Manual
Displayed below is the user manual for PAC527LFCW by Chief which is a product in the Rack Cabinets category. This manual has pages.
Related Manuals
I N S T A L L A T I O N I N S T R U C T I O N S
PAC527L
PAC527LF
PAC527LFC
PAC527LFxP4
PAC527LFxP6
PAC527F-KIT
PAC527CVR-KIT
In-Wall Box w/LeverLock™ and Accessories
PAC527L Series
PAC527L Series Installation Instructions
2
DISCLAIMER
Legrand | AV and its affiliated corporations and subsidiaries
(collectively “Legrand | AV”), intend to make this manual
accurate and complete. However, Legrand | AV makes no claim
that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Legrand | AV
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Legrand | AV
assumes no responsibility for accuracy, completeness or
sufficiency of the information contained in this document.
Chief® is a registered trademark of Legrand AV Inc.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all accessories are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this accessory can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this accessory is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
accessory.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located in the accessory does not exceed
40 lbs (18.1 kg).
• Each PAC527L may hold up to 4 individual backplanes
(2 complete) and each individual backplane may hold a
maximum weight of 10 lbs (4.5 kg)
• A half backplane (after separation) may hold a
maximum weight of 5 lbs (2.3 kg).
WARNING: Use this accessory only for its intended use as
described in these instructions. Do not use attachments not
recommended by the manufacturer.
WARNING:
Never operate this accessory if it is damaged.
Return the accessory to a service center for examination and
repair.
WARNING: For indoor use only.
IMPORTANT ! : The PAC527L accessory is designed to be
mounted to either a 2" x 3" or 2" x 4" wood stud wall 16" or 24"
on center, or a 2" x 3"-25ga (minimum) or 2" x 4"-25ga
(minimum) steel studs wall.
NOTE: Spacings - Minimum spacings between the 120 Vac
power components and the A/V components shall be
maintained for safe operation of the equipment when
installed in accordance with the National Electric Code,
ANSI/NFPA 70.
NOTE: When selecting a Listed 120 Vac Receptacle for use as
the main power source for the PAC series boxes (to
power the A/V equipment), make sure that AC
Receptacle is rated at least 15A and it is used in the
building’s AC branch circuit that is connected to a
circuit breaker rated at least 15A. Do not connect more
than 12A from the Receptacle.
In the U.S., the equipment shall be installed per the applicable
requirements of the National Electrical Code, CSA C22.1.
In Canada, the equipment shall be installed per the applicable
requirements of the National Electrical Code, ANS/NFPA 70.
NOTE:
It is the installer’s responsibility to ensure that the
enclosure is bonded to the ground in the switch box, in
accordance with the National Electric Code, ANSI/NFPA
70 or Canadian Electrical Code, CSA C22.1. A green
grounding screw is provided in the enclosure for the
purpose, if required.
IMPORTANT ! : The PAC527L mounts are designed to
accommodate the following Chief power kits ONLY:
• PAC527P4-KIT
• PAC527P6-KIT
--SAVE THESE INSTRUCTIONS--
DIMENSION DRAWINGS are located at the end of these
Installation Instructions.
Installation Instructions PAC527L Series
3
ADDITIONAL SAFETY INSTRUCTIONS
SPECIFIC TO PAC527FxP4 / PAC527FxP6
READ ALL INSTRUCTIONS BEFORE USING THIS
PRODUCT!!!!
DANGER: TO REDUCE THE RISK OF
ELECTRIC SHOCK:
1. Always turn off power at source before installing the outlet.
WARNING: TO REDUCE THE RISK OF
BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS:
• Always turn off power at source before servicing or
removing the outlet.
• Do not use outdoors - For indoor use only.
• Route cables as shown in these installation
instructions.
• To disconnect, turn off power at source.
WARNING: RISK OF ELECTRIC SHOCK!
Make sure the outlet is properly grounded. See grounding
instructions.
CAUTION: This equipment must be installed
and assembled by qualified service personnel in accordance
with local building and electrical codes.
NOTE: Knockouts are provided for ease of installation. Any
unused knockouts that have been punched are to be
closed up with a metal plug.
Ambient Temperature - The manufacturer’s maximum ambient
temperature is 104°F (40°C) and minimum ambient
temperature is 30°F (-1°C) so that the installer is able to
determine acceptability of use of Accessories and components.
--SAVE THESE INSTRUCTIONS--
IMPORTANT ! : DIMENSION DRAWINGS are located at
the end of these Installation Instructions.
TABLE OF CONTENTS
IMPORTANT ! : DIMENSION DRAWINGS are located at the end of these Installation Instructions.
Installation Instructions PAC527L Series
4
LEGEND
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
Hex-Head Wrench
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Adjust
Ajustar
Einstellen
Ajustar
Regolare
Afstellen
Ajuster
Remove
Quitar
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Optional
Opcional
Optional
Opcional
Opzionale
Optie
En option
Security Wrench
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
PAC527L Series Installation Instructions
5
TOOLS REQUIRED FOR INSTALLATION
PARTS INCLUDED
3/16"
1/4" } OPTIONAL
E (1)
[PAC527]
F (1)
[Template/
A (4)
1/4 x 2-1/2"
C (8)
06 x 3/8"
B (8)
06-32"
D (4)
3/8"
Temporary Cover]
G (1)
[PAC527F]
F (1)
[Template/
A (4)
1/4 x 2-1/2"
C (8)
06 x 3/8"
B (8)
06-32"
D (4)
3/8"
Temporary Cover]
H (1)
[PAC527FC]
F (1)
[Template/
A (4)
1/4 x 2-1/2"
C (8)
06 x 3/8"
B (8)
06-32"
D (4)
3/8"
Temporary Cover]
PAC527L
PAC527LF
PAC527LFC
+ PACL2
and hardware
+ PACL2
and hardware
+ PACL2
and hardware
Installation Instructions PAC527L Series
6
PARTS - continued
J (1)
[PAC527LFxP4]
F (1)
[Template/
A (4)
1/4 x 2-1/2"
C (8)
06 x 3/8"
B (8)
06-32"
D (4)
3/8"
Temporary Cover]
PAC527LFxP4
K (1)
[PAC527LFxP6]
F (1)
[Template/
A (4)
1/4 x 2-1/2"
C (8)
06 x 3/8"
B (8)
06-32"
D (4)
3/8"
Temporary Cover]
PAC527LFxP6
L (1)
[Flange]
F (1)
[Template/
M (8)
10-24 x 1/4"
Temporary Cover]
PAC527F-KIT
N (1)
[Cover]
PAC527CVR-KIT P (2)
#06 x 1-1/4" Q (2)
#06 x 1-1/2"
S (2)
.259 x .156 x .625" T (2)
#06
R (1)
1/8"
[security]
PACL2
U (2)
[Backplane] W (4)
#10-24 x 5/8"
V (8)
[Adapter]
X (8)
#10-24 x 1/4"
+ PACL2
and hardware
+ PACL2
and hardware
(not used)
PAC527L Series Installation Instructions
7
OPTIONAL PARTS PER CUSTOM CONFIGURATION (NOT INCLUDED)
ADDITIONAL INFORMATION
Conduit pipe 1/2", 1" or 1-1/4"
Conduit connectors 3" x 2" Steel Old
Work Switch Box
(2" deep)
Raco #420 or
equivalent
Electrical
outlet Narrow Handy Box
Cover, Duplex
Raco #864 or
equivalent
NOTE: Grounding screw installed at factory in PAC527L, PAC527LF, PAC527LFC, PAC527LFxP4, and
10-32
grounding screw
Earthing symbol IEC 60418 No. 5019
affixed adjacent to grounding terminal
PAC527LFxP6 in-wall boxes. Grounding screw is located on one side of the PAC527L box.
ASSEMBLY AND INSTALLATION
IMPORTANT ! : In the following instructions, the
reference to PAC527L includes the following models:
• PAC527L
• PAC527LF
• PAC527LFC
• PAC527LFxP4
• PAC527LFxP6
The PAC527L is intended for use in both installations where an
existing finished drywall wall is present, and where the wall
surface has not been finished and the structural studs are
exposed. The wall then must be finished around the opening of
the box after the box has been installed.
Locating PAC527L
1. Identify a suitable wall location for the accessory.
2. Locate and mark studs using a stud sensor.
3. Identify possible structural conflicts (electrical wiring,
plumbing, gas lines, HVAC).
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES
CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY!
ALWAYS make certain area behind mounting surfaces is free
of electrical wires and cables before cutting, drilling or
installing fasteners.
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH
OR SERIOUS PERSONAL INJURY. ALWAYS make certain
area behind mounting surfaces is free of gas, water, waste or
any other plumbing before cutting, drilling or installing
fasteners.
4. Determine all additional/optional components required:
• Conduit pipe
• Conduit connectors (both large and small)
• Electrical box(es) (3" x 2")
• Steel electrical box cover(s)
• Electrical outlet(s)
WARNING: All wiring should be
performed by a licensed electrician following
all local codes and ordinances.
PAC527L Series Installation Instructions
8
INSTRUCTIONS FOR PAC527LFxP4 /
PAC527LFxP6 Only
Isolated Ground Receptacle
This product incorporates an isolated ground receptacle,
identified by the orange triangle on its face. This feature may be
useful to reduce common noise in the connected equipment. Its
intended use is to reduce electrical noise (electromagnetic
interference) by purposely insulating the grounding circuit from
any metallic wiring system. The ground pin of the receptacle is
connected to the green/yellow wire and is isolated from the
metal mounting yoke of the receptacle. The accessible metal of
the product is connected to the green wire. If it is not desired to
use this feature, connect the green/yellow and green wires
together.
References
Application Guide for Isolated Ground Wiring Devices 2007,
National Electrical Manufacturers Association (NEMA)
IEEE Std 1100™-2005, “IEEE Recommended Practice for
Powering and Grounding Electronic Equipment” (Emerald
Book), Section 8.5.3.2.
IEEE Std 142™-2007, “IEEE Recommended Practice for
Grounding of Industrial and Commercial Power Systems”
(Green Book), Sections 5.5.1, 5.5.2
NFPA-70, “National Electrical Code”, Article 250.146
Connecting Receptacle Grounding Terminal to Box.
• (D) Isolated Ground Receptacles. Where installed
for the reduction of electrical noise (electromagnetic
interference) on the grounding circuit, a receptacle
in which the grounding terminal is purposefully
insulated from the receptacle mounting means shall
be permitted. The receptacle grounding terminal
shall be connected to an insulated equipment
grounding conductor run with the circuit conductors.
This equipment grounding conductor shall be
permitted to pass through one or more panel boards
without a connection to the panel board grounding
terminal bar as permitted in 408.40, Exception, so
as to terminate within the same building or structure
directly at an equipment grounding conductor
terminal of the applicable derived system or service.
Where installed in accordance with the provisions of
this section, this equipment grounding conductor
shall also be permitted to pass through boxes, wire
ways, or other enclosures without being connected
to such enclosures.
• Informational Note: Use of an isolated equipment
grounding conductor does not relieve the
requirement for grounding the raceway system and
outlet box.
C22.2 No. 1, “Canadian Electrical Code, Part 1”, Rule 10-906
Bonding conductor connection to circuits and equipment.
• (6) A bonding jumper shall be installed to connect
the bonding conductor to the grounding terminal of
a receptacle and in such a manner that
disconnection or removal of the receptacle will not
interfere with, or interrupt grounding continuity.
• (7) In the case of metallically enclosed systems
where the grounding path is provided by the metal
enclosure, a bonding jumper shall be installed to
bond the grounding terminal of the receptacle to the
enclosure.
• (8) Notwithstanding Sub-rules (6) and (7), the
bonding jumper, in the case of receptacles having
grounding terminals isolated from the mounting
strap required for special equipment, shall be
permitted to be extended directly back to the
distribution panel.
WARNING: IMPROPER INSTALLATION CAN RESULT IN
DEATH OR SERIOUS PERSONAL INJURY! This enclosure
should be installed by qualified personnel.
NOTE: The PAC527LFxP4 and PAC527LFxP6 must be
connected to a 15 Amp branch circuit.
Prepare for Wiring
1. Remove and save three Phillips head screws holding power
kit within box. (See Figure 1)
2. Remove the power kit from the in-wall box. (See Figure 1)
Figure 1
1
x 3
2
(PAC527LFxP4
shown as example)
Lower tab
on power kit
Power kit
4
Fit slots in power kit
lower tab around
two fasteners
Installation Instructions PAC527L Series
9
3. Wire the outlet box(es) as required. Refer to Table 1 and
Table 2 for input and output specifications. (See Figure 2)
Table 1: Input Specifications
Table 2: Output Specifications
CAUTION: Isolated ground-mounting means NOT
grounded. Grounding wire connection required.
IMPORTANT ! : If a separate isolated green/yellow
ground wire is installed in the building wiring, attach it
separately to the green/yellow isolated ground wire on
box. If there is no separate green/yellow isolated ground
wire, connect green ground wire to both green/yellow
isolated ground wire and green box ground wire on box.
NOTE: The grounding conductors serving this outlet are to be
connected to earth ground at the service equipment or
other acceptable building earth ground such as the
building frame in the case of a high-rise steel-frame
structure. Connections should be made with minimum
AWG 14 copper wire intended for use on a 15 Amp
circuit. The conductors used to connect the outlet to the
line or bus and ground shall not be any longer than
necessary and shall avoid unnecessary bends.
NOTE: An insulated grounding conductor that is identical in
size and insulation material and thickness to the
grounded and ungrounded circuit supply conductors,
except that it is green with or without one or more
yellow stripes, is to be installed as part of the circuit that
supplies the outlet. Refer to Table 250-122 of the
National Electrical Code regarding the appropriate size
of the grounding conductor.
NOTE: Pressure terminal or pressure splicing connectors and
soldering lugs used in the installation of the outlet shall
be identified as being suitable for the material of the
conductors. Conductors of dissimilar metals shall not
be intermixed in a terminal or splicing connector where
physical contact occurs between dissimilar conductors
unless the device is identified for the purpose and
conditions of use.
Figure 2
4. Replace the power kit in the PAC527L, fitting the two slots
in the power kit lower tab around two fasteners in the
PAC527L. (See Figure 1) and (See Figure 2)
5. Tighten three Phillips screws to secure power kit in the
PAC527L. (See Figure 2)
Outlet Box Use
NOTE: The "PROTECTED" light indicates that the surge
protection circuitry is active and operational.
Figure 3
Input
Input voltage, frequency 125 V AC, 60 Hz
Input connection type 4x14 AWG stranded, UL Style
1015, CSA TEW
Input Wire colors Black - Line
White - Neutral
Green - Box Ground
Green/Yellow - Isolated Ground
Input wire length (ft.) 1 (with a 3/4" stripped end)
Output
Output 15 A, 1875 W
Power consumption <0.5 watt
Fuses Thermal current interrupting circuits
are in MOVs
Quantity/Type Duplex NEMA 5-15R Isolated Ground
Receptacle
Color/Markings Grey with protection symbol (Orange
triangle)
4
GREEN
(box ground)
5
x 3
(PAC527LFxP4
shown as example)
WHITE
(neutral)
BLACK
(line)
GREEN/YELLOW
(isolated ground)
Lower tab
on power kit
"PROTECTED"
indicator light
(PAC527LFxP4
shown as example)
PAC527L Series Installation Instructions
10
PAC527L Site Preparation
1. Using a level, draw a horizontal line at the lower edge of the
install site. (See Figure 4)
2. Create an exploratory hole to confirm edge of the studs.
3. Using the line drawn in Step 1 as lower edge and placing
between studs, use the enclosed template (F) to draw lines
around corners of template, and connect lines on bottom,
top and sides. (See Figure 4)
Figure 4
4. Cut along outside edge of line using a utility knife and
remove drywall.
5. Check stud depth within the wall.
• If 3-1/2" or greater, proceed to PAC527L Box
Preparation and Installation.
• If less than 3-1/2" deep, proceed to Step 6.
6. If present, remove box flange by loosening screws. (See
Figure 5)
CAUTION: Injury may occur on sharp edges. Carefully
discard the removable tabs. Avoid sharp edges.
7. Snap off removable tabs at perforations provided.
8. Reinstall box flange.
9. Fasten flange in place by tightening screws loosened in
Step 6.
Figure 5
PAC527L Box Preparation and Installation
1. Remove knock-outs as determined in Step 4 of Locating
PAC527L section. (See Figure 6)
Figure 6
3
1
3
3
(F)
6
x 8
Flange
6
8
9
1
Installation Instructions PAC527L Series
11
2. Loosely attach required conduit and conduit connectors,
switch boxes, outlets, etc (not included) to PAC527L to
enable fitting into the wall opening. (See Figure 7)
Figure 7
3. Feed conduit attached to PAC527L through cut-out in wall
and insert PAC527L into wall opening. Tighten component
connections.
4. Drill pilot holes (at least 2 on each side of PAC527L) into
studs through mounting holes in PAC527L.
• Wood studs: use 3/16" drill bit
• Steel studs: use 1/4" drill bit
5. Install PAC527L to studs using four 1/4 x 2-1/2" Phillips flat
head screws (A) and four 3/8" flat washers (D) through
PAC527L and pilot holes. (See Figure 8)
Figure 8
NOTE: If installing in a stud wall BEFORE the drywall is
installed, remove outer flange from PAC527L before
installing the PAC527L. (See Figure 9)
Figure 9
(C x 4)
2
Use four 06 x 3/8" Phillips
screws (C) and four 06-32"
nuts (B) to assemble switch
box from either inside or
outside the PAC527L.
(A) x 4
5
(D) x 4
4
x 2 (minimum)
each side
PAC527L Series Installation Instructions
12
Installing LeverLock™ Backplanes
1. Partially install #10-24 x 1/4" Phillips screws with external
tooth washers (X) into holes on sides of PAC box. (See
Figure 10)
2. Slide each adapter (V) inside PAC box. (See Figure 10)
3. Tighten #10-24 x 1/4" Phillips screws with external tooth
washers (X) to secure adapter (V) to PAC box. (See Figure
10)
Figure 10
4. Slide LeverLock™ backplanes (U) into adapter (V) slots on
one side of PAC527L box (A). (See Figure 11)
Figure 11
5. Slide LeverLock™ backplanes into adapter slots on
opposite side, making sure it "clicks" into place. (See Figure
12)
Figure 12
6. If required, break the LeverLock™ backplanes (U) along the
scored mid-line. (See Figure 13)
Figure 13
7. Attach components to LeverLock™ backplanes following
component manufacturer’s instructions.
2
1
(X)
(PACL2 shown)
3
start
tighten
(V)
4
4
4
(U)
(V)
lever lock™ latch lever
5
Mid-line
6
Installation Instructions PAC527L Series
13
Adding Template/Temporary Cover
NOTE: OPTIONAL: Install template (F), if necessary, as a
temporary cover to protect interior of PAC527L box
from debris.
1. Fold tabs of template (F) in and insert into PAC527L
opening. (See Figure 14)
Figure 14
PAC527F-KIT
1. Loosely install eight 10-24 x 1/4" Phillips head screws with
external teeth (M) into holes in PAC527L sides. (See Figure
15)
NOTE:
If the outer edge of the PAC527L needs to be removed,
use the inner hole for flange attachment. (See Figure 15)
Figure 15
2. Slide flange (L) into PAC527L over installed screws, and
tighten screws. (See Figure 16)
Figure 16
PAC527CVR-KIT
1. Break away the tab(s) on the cover (N) to allow wire exit
from the PAC527L, and to meet ventilation needs of the
components. (See Figure 17)
Figure 17
(F)
Outer hole
Inner hole
(M) x 8
(L)
2
2
(M) x 8
(N)
Break away tab(s)
1
PAC527L Series Installation Instructions
14
2. Gather all wires and route through the cover opening(s).
(See Figure 18)
3. Install cover (N) and fasten with two #6 x 1-1/4" Phillips self-
tapping screws (P) [#6 x 1-1/2" button head self-tapping
screws (Q) for security], two spacers (S) and two #6 lock
washers (T). (See Figure 18)
Figure 18
(N)
(S)
(P or Q) x 2
(T)
Installation Instructions PAC527L Series
15
DIMENSIONS
10.00
254.0
12.34
313.3
5.00
127.0
PANEL
SEPARATION
FEATURE
NOTE:
1. TWO PIECES (ONE PIECE SHOWN ABOVE),
INCLUDED WITH ENCLOSURE
A
A
14.25
362.0
3.94
100.0
6.37
161.9
0.34
8.6
MOUNTING
HOLE KNOCKOUT
22.00
558.8
BREAK-OFF
REGION FOR
2 1/2" WALL
INSTALLATION
2.38
60.3
2.38
60.3
2.00
50.8
0.88
22.2
TRADE CONDUIT SIZE 1/2"
METRIC CONDUIT SIZE 16mm
1.38
34.9
TRADE CONDUIT SIZE 1"
METRIC CONDUIT SIZE 27mm
1.73
44.0
TRADE CONDUIT SIZE 1-1/4"
METRIC CONDUIT SIZE 35mm
DETAIL A
SCALE 1 : 1.5
0.11
2.9
1.13
28.6
3.74
94.9
PAC527L
DIMENSIONS: INCHES
[MILLIMETERS]
PAC527L Series Installation Instructions
16
DIMENSIONS - continued
10.00
254.0
5.00
127.0
12.34
313.3
PANEL
SEPARATION
FEATURE
NOTE:
1. TWO PIECES (ONE PIECE SHOWN ABOVE),
INCLUDED WITH ENCLOSURE
23.26
590.9
15.40
391.1
F
F
0.34
8.6
MOUNTING
HOLE KNOCKOUT
22.00
558.8
BREAK-OFF
REGION FOR
2 1/2" WALL
INSTALLATION
2.38
60.3
2.38
60.3
2.00
50.8
0.88
22.2
TRADE CONDUIT SIZE 1/2"
METRIC CONDUIT SIZE 16mm
1.38
34.9
TRADE CONDUIT SIZE 1"
METRIC CONDUIT SIZE 27mm
1.73
44.0
TRADE CONDUIT SIZE 1-1/4"
METRIC CONDUIT SIZE 35mm
0.11
2.9
1.13
28.6
PAC527LF
DIMENSIONS: INCHES
[MILLIMETERS]
Installation Instructions PAC527L Series
17
DIMENSIONS - continued
10.00
254.0
5.00
127.0
12.34
313.3
PANEL
SEPARATION
FEATURE
LATCH LEVER
NOTE:
1. TWO PIECES (ONE PIECE SHOWN ABOVE),
INCLUDED WITH ENCLOSURE
23.26
590.9
15.40
391.1
F
F
0.34
8.6
MOUNTING
HOLE KNOCKOUT
1.74
44.1
2.00
50.8
11.00
279.4
0.88
22.2
TRADE CONDUIT SIZE 1/2"
METRIC CONDUIT SIZE 16mm
1.38
34.9
TRADE CONDUIT SIZE 1"
METRIC CONDUIT SIZE 27mm
1.73
44.0
TRADE CONDUIT SIZE 1-1/4"
METRIC CONDUIT SIZE 35mm
DETAIL A
SCALE 1 : 1.5
2.09
53.1
3.74
94.9
1.13
28.6
0.11
2.9
DETAIL B
SCALE 2 : 5
3.50
88.9
5.00
127.0
5.00
127.0
PAC527LFC
DIMENSIONS: INCHES
[MILLIMETERS]
PAC527L Series Installation Instructions
18
DIMENSIONS - continued
PAC527LFxPx
PAC527FxP6
NOTE:
TWO REMOVABLE PANELS INCLUDED WITH EACH ENCLOSURE
SHOWN HERE IN A STACKED CONFIGURATION
NOTE:
TWO REMOVABLE PANELS INCLUDED WITH EACH ENCLOSURE
SHOWN HERE IN A STACKED CONFIGURATION
PAC527LFxP4 PAC527LFxP6
PAC527LFxPx
DIMENSIONS: INCHES
[MILLIMETERS]
Installation Instructions PAC527L Series
19
DIMENSIONS - continued
23.26
590.9
15.40
391.1
13.90
353.0
21.76
552.8
4.75
120.7
0.43
11.0
PAC527F-KIT
DIMENSIONS: INCHES
[MILLIMETERS]
13.38
339.7
13.81
350.8
21.75
552.5
1.50
38.0
5.00
127.0
3.63
92.1
0.69
17.5
PAC527CVR-KIT
DIMENSIONS: INCHES
[MILLIMETERS]
PAC527L Series Installation Instructions
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P800.582.6480 / 952.225.6000
F877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P+31 (0) 495 580 852
F+31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P852 2145 4099
F852 2145 4477
8800-003183 Rev00
2020 Legrand | AV
www.legrandav.com
06/20