Table of Contents
- Dell PowerEdge R530 Owner's Manual
- About your system
- Performing initial system configuration
- Pre-operating system management applications
- Navigation keys
- About System Setup
- Entering System Setup
- System Setup Main Menu
- System BIOS screen
- System Information screen
- Memory Settings screen
- Processor Settings screen
- SATA Settings screen
- Boot Settings screen
- Network Settings screen
- Integrated Devices screen details
- Serial Communication screen
- System Profile Settings screen
- System Security Settings screen
- Miscellaneous Settings screen
- About Boot Manager
- About Dell Lifecycle Controller
- Changing the boot order
- Choosing the system boot mode
- Assigning a system and setup password
- Using your system password to secure your system
- Deleting or changing an existing system and/or setup password
- Operating with a setup password enabled
- Embedded system management
- iDRAC Settings utility
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Front bezel (optional)
- Removing and installing the system cover
- Inside the system
- Cooling shroud
- System memory
- Hard drives
- Removing a hot-swap hard drive
- Installing a hot-swap hard drive
- Removing a 3.5 inch hard-drive blank
- Installing a 3.5 inch hard-drive blank
- Removing a 2.5 inch hard drive from a 3.5 inch hard-drive adapter
- Installing a 2.5 inch hard drive into a 3.5 inch hard-drive adapter
- Removing a hard-drive adapter from a hard-drive carrier
- Installing a hard-drive adapter into a hard-drive carrier
- Removing a hard drive from a hard-drive carrier
- Installing a hard drive into a hard-drive carrier
- Optical drive (optional)
- Cooling fans
- Internal USB memory key (optional)
- Expansion cards and expansion-card riser (optional)
- Expansion-card installation guidelines
- Removing an expansion card from the system board
- Installing an expansion card on the system board
- Removing the (optional) expansion-card riser
- Installing the (optional) expansion-card riser
- Removing an expansion card from the expansion-card riser
- Installing an expansion card into the expansion-card riser
- iDRAC ports card (optional)
- SD vFlash media card
- Internal dual SD module
- Integrated storage controller card
- Processors
- Power supplies
- Hot Spare feature
- Removing the power supply unit blank
- Installing the power supply unit blank
- Removing an AC power supply unit
- Installing an AC power supply unit
- Non-redundant AC power supply (cabled)
- Wiring instructions for a DC power supply unit
- Removing a DC power supply unit
- Installing a DC power supply unit
- Power interposer board
- System battery
- Hard-Drive Backplane
- Control panel and I/O module
- System board
- Trusted Platform Module
- Troubleshooting your system
- Safety first—for you and your system
- Troubleshooting system startup failure
- Troubleshooting external connections
- Troubleshooting the video subsystem
- Troubleshooting a USB device
- Troubleshooting a serial I/O device
- Troubleshooting a NIC
- Troubleshooting a wet system
- Troubleshooting a damaged system
- Troubleshooting the system battery
- Troubleshooting power supply units
- Power source problems
- Power supply unit problems
- Troubleshooting cooling problems
- Troubleshooting cooling fans
- Troubleshooting system memory
- Troubleshooting an internal USB key
- Troubleshooting an SD card
- Troubleshooting an optical drive
- Troubleshooting a hard drive
- Troubleshooting a storage controller
- Troubleshooting expansion cards
- Troubleshooting processors
- System messages
- Using system diagnostics
- Jumpers and connectors
- Technical specifications
- Getting help
DELL R530 User Manual
Displayed below is the user manual for R530 by DELL which is a product in the Servers category. This manual has pages.
Related Manuals
Dell PowerEdge R530
Owner's Manual
Regulatory Model: E29S Series
Regulatory Type: E29S001
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and
intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other
jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2014 - 11
Rev. A00
Contents
1 About your system................................................................................................ 8
Front-panel features and indicators.....................................................................................................8
LCD panel features..............................................................................................................................10
Home screen................................................................................................................................. 10
Setup menu.................................................................................................................................... 11
View menu......................................................................................................................................11
Hard-drive indicator patterns..............................................................................................................12
Back-panel features and indicators.................................................................................................... 13
NIC indicator codes.............................................................................................................................15
Power supply unit indicator codes..................................................................................................... 15
Power indicator codes for AC and DC redundant power supply unit.........................................15
Indicator codes for non-redundant power supply...................................................................... 18
Documentation matrix........................................................................................................................ 19
Quick Resource Locator (QRL)...........................................................................................................20
2 Performing initial system configuration ........................................................21
Setting up your system........................................................................................................................21
Setting up and configuring the iDRAC IP address .............................................................................21
Logging in to iDRAC............................................................................................................................ 21
Installing the operating system...........................................................................................................22
Managing your system remotely........................................................................................................ 22
Downloading and installing drivers and firmware............................................................................. 22
3 Pre-operating system management applications........................................24
Navigation keys................................................................................................................................... 24
About System Setup............................................................................................................................24
Entering System Setup.................................................................................................................. 25
System Setup Main Menu..............................................................................................................25
System BIOS screen...................................................................................................................... 25
System Information screen...........................................................................................................26
Memory Settings screen............................................................................................................... 26
Processor Settings screen.............................................................................................................27
SATA Settings screen.....................................................................................................................28
Boot Settings screen......................................................................................................................31
Network Settings screen............................................................................................................... 31
Integrated Devices screen details.................................................................................................32
Serial Communication screen...................................................................................................... 33
System Profile Settings screen......................................................................................................34
System Security Settings screen................................................................................................... 35
Miscellaneous Settings screen......................................................................................................37
About Boot Manager...........................................................................................................................38
Entering Boot Manager ................................................................................................................38
Boot Manager main menu............................................................................................................ 38
About Dell Lifecycle Controller.......................................................................................................... 38
Changing the boot order....................................................................................................................39
Choosing the system boot mode.......................................................................................................39
Assigning a system and setup password............................................................................................39
Using your system password to secure your system........................................................................40
Deleting or changing an existing system and/or setup password.................................................... 41
Operating with a setup password enabled.........................................................................................41
Embedded system management....................................................................................................... 42
iDRAC Settings utility.......................................................................................................................... 42
Entering the iDRAC Settings utility............................................................................................... 42
Changing the Thermal Settings.................................................................................................... 42
4 Installing and removing system components...............................................43
Safety instructions...............................................................................................................................43
Before working inside your system.................................................................................................... 43
After working inside your system....................................................................................................... 43
Recommended tools.......................................................................................................................... 44
Front bezel (optional)..........................................................................................................................44
Removing the front bezel............................................................................................................. 44
Installing the front bezel............................................................................................................... 45
Removing and installing the system cover........................................................................................ 45
Removing the system cover......................................................................................................... 46
Installing the system cover........................................................................................................... 46
Inside the system.................................................................................................................................47
Cooling shroud................................................................................................................................... 49
Removing the cooling shroud......................................................................................................49
Installing the cooling shroud.........................................................................................................51
System memory...................................................................................................................................51
General memory module installation guidelines.........................................................................53
Mode-specific guidelines..............................................................................................................53
Sample memory configurations................................................................................................... 54
Removing a memory module.......................................................................................................56
Installing memory modules.......................................................................................................... 58
Hard drives.......................................................................................................................................... 60
Removing a hot-swap hard drive.................................................................................................60
Installing a hot-swap hard drive....................................................................................................61
Removing a 3.5 inch hard-drive blank......................................................................................... 62
Installing a 3.5 inch hard-drive blank........................................................................................... 63
Removing a 2.5 inch hard drive from a 3.5 inch hard-drive adapter..........................................64
Installing a 2.5 inch hard drive into a 3.5 inch hard-drive adapter..............................................65
Removing a hard-drive adapter from a hard-drive carrier..........................................................65
Installing a hard-drive adapter into a hard-drive carrier............................................................. 66
Removing a hard drive from a hard-drive carrier........................................................................ 66
Installing a hard drive into a hard-drive carrier............................................................................ 67
Optical drive (optional)........................................................................................................................67
Removing the optical drive........................................................................................................... 67
Installing the optical drive.............................................................................................................68
Cooling fans........................................................................................................................................ 69
Removing a cooling fan................................................................................................................69
Installing a cooling fan...................................................................................................................71
Internal USB memory key (optional)...................................................................................................71
Replacing the internal USB key..................................................................................................... 71
Expansion cards and expansion-card riser (optional)........................................................................72
Expansion-card installation guidelines.........................................................................................73
Removing an expansion card from the system board.................................................................75
Installing an expansion card on the system board...................................................................... 76
Removing the (optional) expansion-card riser.............................................................................77
Installing the (optional) expansion-card riser...............................................................................78
Removing an expansion card from the expansion-card riser..................................................... 79
Installing an expansion card into the expansion-card riser.........................................................81
iDRAC ports card (optional)................................................................................................................82
Removing the iDRAC ports card...................................................................................................82
Installing the iDRAC ports card.....................................................................................................84
SD vFlash media card..........................................................................................................................84
Replacing an SD vFlash media card..............................................................................................84
Internal dual SD module..................................................................................................................... 85
Removing an internal SD card...................................................................................................... 85
Installing an internal SD card........................................................................................................86
Removing the internal dual SD module ...................................................................................... 87
Installing the internal dual SD module ........................................................................................ 89
Integrated storage controller card.....................................................................................................90
Removing the integrated storage controller card....................................................................... 90
Installing the integrated storage controller card......................................................................... 92
Processors........................................................................................................................................... 92
Removing a processor.................................................................................................................. 93
Installing a processor.................................................................................................................... 97
Power supplies..................................................................................................................................100
Hot Spare feature........................................................................................................................100
Removing the power supply unit blank..................................................................................... 100
Installing the power supply unit blank........................................................................................101
Removing an AC power supply unit........................................................................................... 101
Installing an AC power supply unit.............................................................................................102
Non-redundant AC power supply (cabled)................................................................................103
Wiring instructions for a DC power supply unit.........................................................................105
Removing a DC power supply unit.............................................................................................108
Installing a DC power supply unit...............................................................................................109
Power interposer board.................................................................................................................... 110
Removing the power interposer board...................................................................................... 110
Installing the power interposer board.........................................................................................112
System battery................................................................................................................................... 112
Replacing the system battery...................................................................................................... 112
Hard-Drive Backplane....................................................................................................................... 114
Removing the hard-drive backplane.......................................................................................... 114
Installing the hard-drive backplane............................................................................................ 116
Control panel and I/O module..........................................................................................................117
Removing the control-panel board............................................................................................ 117
Installing the control-panel board..............................................................................................118
Removing the control panel........................................................................................................119
Installing the control panel.........................................................................................................120
System board..................................................................................................................................... 121
Removing the system board........................................................................................................121
Installing the system board......................................................................................................... 123
Restoring the Service Tag using Easy Restore............................................................................125
Entering the system Service Tag using System Setup................................................................125
Trusted Platform Module..................................................................................................................126
Installing the Trusted Platform Module .....................................................................................126
Re-enabling the TPM for BitLocker users...................................................................................127
Re-enabling the TPM for TXT users............................................................................................127
5 Troubleshooting your system........................................................................ 128
Safety first—for you and your system...............................................................................................128
Troubleshooting system startup failure........................................................................................... 128
Troubleshooting external connections............................................................................................128
Troubleshooting the video subsystem.............................................................................................128
Troubleshooting a USB device......................................................................................................... 128
Troubleshooting a serial I/O device................................................................................................. 129
Troubleshooting a NIC......................................................................................................................129
Troubleshooting a wet system......................................................................................................... 130
Troubleshooting a damaged system................................................................................................ 131
Troubleshooting the system battery.................................................................................................131
Troubleshooting power supply units................................................................................................132
Power source problems....................................................................................................................132
Power supply unit problems.............................................................................................................132
Troubleshooting cooling problems..................................................................................................133
Troubleshooting cooling fans...........................................................................................................133
Troubleshooting system memory.................................................................................................... 134
Troubleshooting an internal USB key...............................................................................................135
Troubleshooting an SD card.............................................................................................................135
Troubleshooting an optical drive..................................................................................................... 136
Troubleshooting a hard drive............................................................................................................137
Troubleshooting a storage controller...............................................................................................137
Troubleshooting expansion cards....................................................................................................138
Troubleshooting processors.............................................................................................................139
System messages.............................................................................................................................. 139
Warning messages.......................................................................................................................139
Diagnostic messages...................................................................................................................139
Alert messages............................................................................................................................ 140
6 Using system diagnostics................................................................................141
Dell Embedded System Diagnostics.................................................................................................141
When to use the Embedded System Diagnostics...................................................................... 141
Running the Embedded System Diagnostics............................................................................. 141
System diagnostic controls.........................................................................................................142
7 Jumpers and connectors................................................................................ 143
System board jumper settings.......................................................................................................... 143
System board connectors.................................................................................................................144
Disabling a forgotten password........................................................................................................145
8 Technical specifications..................................................................................147
9 Getting help.......................................................................................................153
Contacting Dell..................................................................................................................................153
Locating your system Service Tag....................................................................................................153
Documentation feedback................................................................................................................. 153
Quick Resource Locator (QRL).........................................................................................................153
1
About your system
The Dell PowerEdge R530 is a rack server that supports up to two processors based on the Intel E5-2600
v3 product family, up to 12 DIMMs, and up to eight drive bays for hard drives/ SSDs.
The PowerEdge R530 system is available in the following configurations:
• Redundant power supply configuration
• Non-redundant power supply configuration
Front-panel features and indicators
Figure 1. Front-panel features and indicators
Item Indicator, Button, or
Connector Icon Description
1 Power-on indicator,
power button
The power-on indicator lights when the system is
powered on. The power button controls the power
supply output to the system.
NOTE: On ACPI-compliant operating systems,
turning off the system using the power button
causes the system to perform a graceful
shutdown before power to the system is
turned off.
2 NMI button Used to troubleshoot software and device driver
errors when using certain operating systems. This
8
Item Indicator, Button, or
Connector Icon Description
button can be pressed using the end of a paper
clip.
Use this button only if directed to do so by
qualified support personnel or by the operating
system's documentation.
3 System identification
button
The identification buttons on the front and back
panels can be used to locate a particular system
within a rack. When one of these buttons is
pushed, the LCD panel on the front and the system
status indicator on the back flash blue until one of
the buttons is pushed again.
Press to toggle the system ID ON and OFF. If the
system hangs during POST, press and hold the
system ID button for more than five seconds to
enter BIOS progress mode.
To reset the iDRAC (if not disabled in F2 iDRAC
setup) press and hold for more than 15 seconds.
4 Video connector Connects a VGA display to the system.
5 LCD menu buttons Allows you to navigate the control panel LCD
menu.
6 LCD panel Displays system ID, status information, and system
error messages. See LCD panel features.
7 USB management port/
iDRAC Direct
Allows you to connect USB devices to the system
or provides access to the iDRAC Direct features.
For more information, see the Integrated Dell
Remote Access Controller User’s Guide at
dell.com/esmmanuals. The USB management port
is USB 2.0-compliant.
8 USB connector Allows you to connect USB devices to the system.
The ports are USB 2.0 compliant.
9 Information tag A slide-out label panel, which allows you to record
system information, such as Service Tag, NIC
addresses, MAC address, and so on, for your
reference.
10 Optical drive (optional) One optional SATA DVD-ROM drive or DVD+/-RW
drive.
NOTE: DVD devices are data only.
11 Hard drives/SSDs bay Up to eight 2.5 inch or 3.5 inch hot-swappable
hard drives/SSDs.
9
LCD panel features
The system's LCD panel provides system information and status and error messages to indicate if the
system is operating correctly or if the system needs attention. For more information on error messages,
see the Dell Event and Error Messages Reference Guide at dell.com/esmmanuals.
• The LCD backlight lights blue during normal operating conditions.
• When the system needs attention, the LCD lights amber, and displays an error code followed by
descriptive text.
NOTE: If the system is connected to a power source and an error is detected, the LCD lights
amber regardless of whether the system is turned on or off.
• The LCD backlight turns OFF when the system is in standby mode and can be turned on by pressing
either the Select, Left, or Right button on the LCD panel.
• The LCD backlight remains OFF if LCD messaging is turned off through the iDRAC utility, the LCD
panel, or other tools.
Figure 2. LCD panel features
Item Button Description
1 Left Moves the cursor back in one-step increments.
2 Select Selects the menu item highlighted by the cursor.
3 Right Moves the cursor forward in one-step increments.
During message scrolling:
• Press once to increase scrolling speed
• Press again to stop
• Press again to return to the default scrolling speed
• Press again to repeat the cycle
Home screen
The Home screen displays user-configurable information about the system. This screen is displayed
during normal system operation when there are no status messages or errors. When the system is in
standby mode, the LCD backlight turns off after five minutes of inactivity if there are no error messages.
Press one of the three navigation buttons (Select, Left, or Right) to view the Home screen.
To navigate to the Home screen from another menu, follow the steps below.
1. Press and hold the up arrow until the Home icon is displayed.
10
2. Select the Home icon.
3. From the Home screen, press the Select button to enter the main menu.
Setup menu
NOTE: When you select an option in the Setup menu, you must confirm the option before
proceeding to the next action.
Option Description
iDRAC Select DHCP or Static IP to configure the network mode. If Static IP is selected,
the available fields are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to
enable DNS and to view domain addresses. Two separate DNS entries are available.
Set error Select SEL to display LCD error messages in a format that matches the IPMI
description in the SEL. This is useful when trying to match an LCD message with an
SEL entry.
Select Simple to display LCD error messages in a simplified user-friendly
description. For more information on error messages, see the Dell Event and Error
Messages Reference Guide at dell.com/esmmanuals.
Set home Select the default information to be displayed on the LCD Home screen. See View
menu to see the options and option items that can be set as the default on the
Home screen.
View menu
NOTE: When you select an option in the View menu, you must confirm the option before
proceeding to the next action.
Option Description
iDRAC IP Displays the IPv4 or IPv6 addresses for iDRAC8. Addresses include DNS (Primary
and Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).
MAC Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Name Displays the name of the Host, Model, or User String for the system.
Number Displays the Asset tag or the Service tag for the system.
Power Displays the power output of the system in BTU/hr or Watts. The display format can
be configured in the Set home submenu of the Setup menu.
Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format
can be configured in the Set home submenu of the Setup menu.
11
Hard-drive indicator patterns
Figure 3. Hard-drive indicators
1. hard-drive activity indicator 2. hard-drive status indicator
3. hard drive
NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator
(on the right side) does not function and remains OFF.
Drive-status indicator
pattern (RAID only) Condition
Blinks green two times per
second
Identifying the drive or preparing for removal.
OFF Drive ready for insertion or removal.
NOTE: The drive status indicator remains OFF until all hard drives are
initialized after the system is turned on. Drives are not ready for
insertion or removal during this time.
Blinks green, amber, and
off
Predicted drive failure
Blinks amber four times per
second
Drive failed
Blinks green slowly Drive rebuilding
Steady green Drive online
12
Drive-status indicator
pattern (RAID only) Condition
Blinks green three seconds,
amber three seconds, and
OFF six seconds
Rebuild aborted
Back-panel features and indicators
Figure 4. Back-panel features and indicators for a non-redundant power supply unit chassis and a redundant
power supply unit chassis
Item Indicator, button, or
connector Icon Description
1 Serial connector Connects a serial device to the system.
2 Ethernet connectors (2) Integrated 10/100/1000 Mbps NIC connector
3 vFlash media card slot
(Optional)
Allows you to insert a vFlash media card.
4 iDRAC port (Optional) Dedicated management port for the iDRAC Ports
Card.
5 Full Height PCIe
expansion card slots (2)
PCIe cards located on the optional expansion-card
riser
6 Redundant Power
Supply Unit AC 495 W EPP, 750 W EPP or
1100 W EPP
Or
DC 750 W
13
Item Indicator, button, or
connector Icon Description
7 Non-Redundant Power
Supply Unit
450 W
8 Half Height PCIe
expansion card slots (5)
Allows you to connect PCIe expansion cards.
9 Ethernet connectors (2) Integrated 10/100/1000 Mbps NIC connector
10 System identification
connector
Connects the optional system status indicator
assembly through the optional cable management
arm.
11 System identification
button
The identification buttons on the front and back
panels can be used to locate a particular system
within a rack. When one of these buttons is
pushed, the LCD panel on the front and the system
status indicator on the back blink until one of the
buttons is pushed again.
Press to toggle the system ID on and off. If the
system hangs during POST, press and hold the
system ID button for more than five seconds to
enter BIOS progress mode.
To reset the iDRAC (if not disabled in System
Setup) press and hold for more than 15 seconds.
12 USB connector Connects USB devices to the system. This port is
USB 3.0-compliant.
13 USB connector Connects USB devices to the system. This port is
USB 2.0-compliant.
14 Video connector Connects a VGA display to the system.
14
NIC indicator codes
Figure 5. NIC indicators
1. link indicator 2. activity indicator
Convention Indicator pattern Description
A Link and activity indicators
are OFF
The NIC is not connected to the network.
B Link indicator is green The NIC is connected to a valid network at its maximum
port speed (1 Gbps).
C Link indicator is yellow The NIC is connected to a valid network at less than its
maximum port speed.
D Activity indicator is blinking
green
Network data is being sent or received.
Power supply unit indicator codes
Power indicator codes for AC and DC redundant power supply unit
Each AC power supply unit (PSU) has an illuminated translucent handle and each DC PSU (when
available) has an LED that serves as an indicator to show whether power is present or a power fault has
occurred.
15
Figure 6. AC power supply unit status indicator
Convention Power indicator
pattern Condition
A Green The handle indicator lights green indicating that a valid power
source is connected to the PSU and that the PSU is operational.
B Flashing green When updating the firmware of thePSU, the PSU handle flashes
green.
CAUTION:
Do not disconnect the power cord or unplug the PSU when
updating firmware. If firmware update is interrupted, the PSUs will
not function. You must roll back the power supply firmware by using
Life cycle controller. See Dell Lifecycle Controller User’s Guide at
dell.com/esmmanuals
C Flashes green
and turns off
When hot-adding a PSU, the handle of the new power supply unit
flashes green five times at 4 Hz rate and turns off. This indicates that
the new PSU is mismatched with the PSU that is installed (in terms of
efficiency, feature set, health status, and supported voltage). Use a
PSU that matches the capacity of the PSU that is installed.
NOTE: For AC power supplies, use only PSUs with the Extended
Power Performance (EPP) label on the back. Mixing PSUs from
previous generations of servers can result in a PSU mismatch
condition or failure to power on.
D Flashing amber Indicates a problem with the power supply unit.
16
Convention Power indicator
pattern Condition
CAUTION: When correcting a PSU mismatch, replace only the
PSU with the flashing indicator. Swapping the opposite power
supply unit to make a matched pair can result in an error
condition and unexpected system shutdown. To change from
a High Output configuration to a Low Output configuration or
vice versa, you must power down the system.
CAUTION: AC power supplies support both 220 V and 110 V
input voltages with the exception of Titanium power supplies,
which support only 220 V. When two identical power supplies
receive different input voltages, they can output different
wattages, and trigger a mismatch.
CAUTION: If two power supplies are used, they must be of the
same type and have the same maximum output power.
CAUTION: Combining AC and DC power supplies is not
supported and triggers a mismatch.
E Not lit Power is not connected.
Figure 7. DC power supply unit status indicator
17
Convention Power indicator
pattern Condition
A Green The handle/LED indicator lights green indicating that a valid power
source is connected to the PSU and that the PSU is operational.
B Flashing green When hot-adding a PSU, the handle of the new power supply unit
flashes green five times at 4 Hz rate and turns off. This indicates
that the new PSU is mismatched with the PSU that is installed (in
terms of efficiency, feature set, health status, and supported
voltage). Use a PSU that matches the capacity of the PSU that is
installed.
C Flashing amber Indicates a problem with the PSU.
CAUTION: When correcting a PSU mismatch, replace only
the PSU with the flashing indicator. Swapping the opposite
PSU to make a matched pair can result in an error condition
and unexpected system shutdown. To change from a High
Output configuration to a Low Output configuration or vice
versa, you must power down the system.
CAUTION: If two power supplies are used, they must be of
the same type and have the same maximum output power.
CAUTION: Combining AC and DC power supplies is not
supported and triggers a mismatch.
D Not lit Power is not connected.
Indicator codes for non-redundant power supply
Press the self-diagnostic button to perform a quick health check on the non-redundant power supply of
the system.
Figure 8. Non-redundant AC power supply status indicator and self-diagnostic button
1. self-diagnostic button 2. AC power supply status indicator
18
Diagnostic Indicator Pattern Description
Not lit Power is not connected or power supply is faulty.
Green A valid power source is connected to the power supply and
the power supply is operational.
Documentation matrix
The documentation matrix provides information on documents that you can refer to for setting up and
managing your system.
To... Refer to...
Install your system into a rack Rack documentation included with your rack
solution
Set up your system and know the system technical
specifications
Getting Started With Your System that shipped with
your system or see dell.com/poweredgemanuals
Install the operating system Operating system documentation at dell.com/
operatingsystemmanuals
Get an overview of the Dell Systems Management
offerings
Dell OpenManage Systems Management Overview
Guide at dell.com/openmanagemanuals
Configure and log in to iDRAC, set up managed
and management system, know the iDRAC
features and troubleshoot using iDRAC
Integrated Dell Remote Access Controller User's
Guide at dell.com/esmmanuals
Know about the RACADM subcommands and
supported RACADM interfaces
RACADM Command Line Reference Guide for
iDRAC and CMC at dell.com/esmmanuals
Launch, enable and disable Lifecycle Controller,
know the features, use and troubleshoot Lifecycle
Controller
Dell Lifecycle Controller User’s Guide at dell.com/
esmmanuals
Use Lifecycle Controller Remote Services Dell Lifecycle Controller Remote Services Quick
Start Guide at dell.com/esmmanuals
Set up, use, and troubleshoot OpenManage Server
Administrator
Dell OpenManage Server Administrator User’s
Guide at dell.com/openmanagemanuals
Install, use and troubleshoot OpenManage
Essentials
Dell OpenManage Essentials User’s Guide at
dell.com/openmanagemanuals
Know the features of the storage controller cards,
deploy the cards, and manage the storage
subsystem
Storage controller documentation at dell.com/
storagecontrollermanuals
Check the event and error messages generated by
the system firmware and agents that monitor
system components
Dell Event and Error Messages Reference Guide at
dell.com/esmmanuals
19
Quick Resource Locator (QRL)
Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to
videos. This can be done by visiting www.dell.com/QRL or by using your smartphone or tablet and a
model specific Quick Resource (QR) code located on your Dell PowerEdge system. To try out the QR
code, scan the following image.
20
2
Performing initial system configuration
After you receive your PowerEdge system, you must set up your system, install the operating system if it
is not pre-installed, and set up and configure the system iDRAC IP address.
Setting up your system
1. Unpack the server.
2. Install the server into the rack. For more information on installing the server into the rack, see your
system Rack Installation Placemat at dell.com/poweredgemanuals.
3. Connect the peripherals to the system.
4. Connect the system to its electrical outlet.
5. Turn the system on by pressing the power button or using iDRAC.
6. Turn on the attached peripherals.
Setting up and configuring the iDRAC IP address
You can set up the Integrated Dell Remote Access Controller (iDRAC) IP address by using one of the
following interfaces:
• iDRAC Settings utility
• Lifecycle Controller
• Dell OpenManage Deployment Toolkit
• Server LCD panel
You can configure iDRAC IP address by using the following interfaces:
• iDRAC Web interface. For more information, see the Integrated Dell Remote Access Controller User's
Guide.
• Remote Access Controller ADMin (RACADM). For more information, see the RACADM Command Line
Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide.
• Remote Services that includes Web Services Management (WS-Man). For more information, see the
Lifecycle Controller Remote Services Quick Start Guide.
For more information on setting up and configuring iDRAC, see the Integrated Dell Remote Access
Controller User's Guide at dell.com/esmmanuals.
Logging in to iDRAC
You can log in to iDRAC as an iDRAC local user, a Microsoft Active Directory user, or a Lightweight
Directory Access Protocol (LDAP) user. You can also log in by using Single Sign-On or a Smart Card. The
21
default user name is root and password is calvin. For more information on logging in to iDRAC and
iDRAC licenses, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmmanuals.
You can also access iDRAC using RACADM. For more information, see the RACADM Command Line
Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide available at
dell.com/esmmanuals.
Installing the operating system
If the server is shipped without an operating system, install the supported operating system on the server
by using one of the following methods:
• Dell Systems Management Tools and Documentation media. See the operating system
documentation at dell.com/operatingsystemmanuals.
• Dell Lifecycle Controller. See the Lifecycle Controller documentation at dell.com/esmmanuals.
• Dell OpenManage Deployment Toolkit. See the OpenManage documentation at dell.com/
openmanagemanuals.
For information on the list of operating systems supported on your system, see the operating systems
support matrix at dell.com/ossupport.
Managing your system remotely
To perform out-of-band systems management using iDRAC, you must configure iDRAC for remote
accessibility, set up the management station and managed system, and configure the supported Web
browsers. For more information, see the Integrated Dell Remote Access Controller User’s Guide at
dell.com/esmmanuals.
You can also remotely monitor and manage the server by using the Dell OpenManage Server
Administrator (OMSA) software and OpenManage Essentials (OME) systems management console. For
more information, see dell.com/openmanagemanuals.
Downloading and installing drivers and firmware
It is recommended that you download and install the latest BIOS, drivers, and systems management
firmware on your system.
Prerequisites
Ensure that you clear the web browser cache.
Steps
1. Go to dell.com/support/drivers.
2. In the Product Selection section, enter the Service Tag of your system in the Service Tag or Express
Service Code field.
NOTE: If you do not have the Service Tag, select Automatically detect my Service Tag for me
to allow the system to automatically detect your Service Tag, or select Choose from a list of all
Dell products to select your product from the Product Selection page.
3. Click Get drivers and downloads.
The drivers that are applicable to your selection are displayed.
22
4. Download the drivers you require to a diskette drive, USB drive, CD, or DVD.
23
3
Pre-operating system management
applications
The pre-operating system management applications for your PowerEdge system help you manage
different settings and features of your system without booting to the operating system.
Your PowerEdge system has the following pre-operating system management applications:
• System Setup
• Boot Manager
• Dell Lifecycle Controller
Navigation keys
The navigation keys can help you access the pre-operating system management applications.
Key Description
<Page Up> Moves to the previous screen.
<Page
Down>
Moves to the next screen.
Up arrow Moves to the previous field.
Down
arrow
Moves to the next field.
<Enter> Enables you to type a value in the selected field (if applicable) or follow the link in the field.
Spacebar Expands or collapses a drop-down list, if applicable.
<Tab> Moves to the next focus area.
NOTE: This feature is applicable for the standard graphical browser only.
<Esc> Moves to the previous page until you view the main screen. Pressing <Esc> in the main
screen exits System BIOS/iDRAC Settings/Device Settings/Service Tag Settings and
proceeds with system boot.
<F1> Displays the System Setup help.
About System Setup
Using System Setup, you can configure the BIOS settings, iDRAC settings, and device settings of your
system.
You can access System Setup in two ways:
24
• Standard Graphical Browser — This is enabled by default.
• Text Browser — This is enabled using Console Redirection.
NOTE: By default, help text for the selected field is displayed in the graphical browser. To view the
help text in the text browser, press <F1>.
Entering System Setup
1. Turn on or restart your system.
2. Press <F2> immediately after you see the following message:
<F2> = System Setup
If your operating system begins to load before you press <F2>, allow the system to finish booting,
and then restart your system and try again.
System Setup Main Menu
Option Description
System BIOS Enables you to configure BIOS settings.
iDRAC Settings Enables you to configure iDRAC settings.
The iDRAC Settings utility is an interface to set up and configure the
iDRAC parameters by using UEFI. You can enable or disable various
iDRAC parameters by using the iDRAC Settings utility. For more
information about this utility, see the Integrated Dell Remote Access
Controller User’s Guide at dell.com/esmmanuals.
Device Settings Enables you to configure device settings.
System BIOS screen
By using the System BIOS screen you can view the BIOS settings as well as edit specific functions such as
Boot Order, System Password, Setup Password, setting the RAID mode, and enabling or disabling USB
ports.
In the System Setup Main Menu, click System BIOS.
Menu Item Description
System Information Displays information about the system such as the system model name,
BIOS version and Service Tag.
Memory Settings Displays information and options related to the installed memory.
Processor Settings Displays information and options related to the processor such as speed,
cache size, and so on.
SATA Settings Displays options to enable or disable the integrated SATA controller and
ports.
Boot Settings Displays options to specify the boot mode (BIOS or UEFI). Enables you to
modify UEFI and BIOS boot settings.
Network Settings Displays options to change the network settings.
Integrated Devices Displays options to enable or disable integrated device controllers and
ports, and to specify related features and options.
25
Menu Item Description
Serial Communication Displays options to enable or disable the serial ports and specify related
features and options.
System Profile Settings Displays options to change the processor power management settings,
memory frequency, and so on.
System Security Displays options to configure the system security settings like, system
password, setup password, TPM security, and so on. It also enables or
disables support for the power and NMI buttons on the system.
Miscellaneous Settings Displays options to change the system date, time, and so on.
System Information screen
You can use the System Information screen to view system properties such as Service Tag, system
model, and the BIOS version.
To view the System Information click System Setup Main Menu → System BIOS → System Information.
Menu Item Description
System Model Name Displays the system model name.
System BIOS Version Displays the BIOS version installed on the system.
System Management
Engine Version
Displays the current revision of the Management Engine firmware.
System Service Tag Displays the system Service Tag.
System Manufacturer Displays the name of the system manufacturer.
System Manufacturer
Contact Information
Displays the contact information of the system manufacturer.
System CPLD Version Displays the current revision of the system CPLD firmware.
UEFI Compliance Version Displays the system firmware UEFI compliance level.
Memory Settings screen
You can use the Memory Settings screen to view all the memory settings as well as enable or disable
specific memory functions such as system memory testing and node interleaving.
To view theMemory Setting screen, click System Setup Main Menu → System BIOS → Memory Settings.
Menu Item Description
System Memory Size Displays the amount of memory installed in the system.
System Memory Type Displays the type of memory installed in the system.
System Memory Speed Displays the system memory speed.
System Memory Voltage Displays the system memory voltage.
Video Memory Displays the amount of video memory utilized.
System Memory Testing Specifies whether system memory tests are run during system boot.
Options are Enabled and Disabled. By default, the System Memory
Testing option is set to Disabled.
Memory Operating Mode Specifies the memory operating mode. The options available are
Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare Mode, and
26
Menu Item Description
Spare with Advanced ECC Mode. By default, the Memory Operating
Mode option is set to Optimizer Mode.
NOTE: The Memory Operating Mode can have different defaults
and available options based on the memory configuration of your
system.
Node Interleaving Specifies if Non-Uniform Memory architecture (NUMA) is supported. If
this field is Enabled, memory interleaving is supported if a symmetric
memory configuration is installed. If Disabled, the system supports
NUMA (asymmetric) memory configurations. By default, Node
Interleaving option is set to Disabled.
Snoop Mode Specifies the Snoop Mode options. Snoop Mode options available are
Home Snoop, Early Snoop, and Cluster on Die. By default, the Snoop
Mode option is set to Early Snoop. The field is only available when Node
Interleaving is Disabled.
Processor Settings screen
You can use the Processor Settings screen to view the processor settings and perform specific functions
such as enabling virtualization technology, hardware prefetcher, and logical processor idling.
To view the Processor Settings screen, click System Setup Main Menu → System BIOS → Processor
Settings.
Menu Item Description
Logical Processor Enables or disables the logical processors and displays the number of
logical processors. If the Logical Processor option is set to Enabled, the
BIOS displays all the logical processors. If this option is set to Disabled,
the BIOS displays only one logical processor per core. By default, the
Logical Processor option is set to Enabled.
Alternate RTID (Requestor
Transaction ID) Setting
Enables you to allocate more RTIDs to the remote socket, thereby
increasing cache performance between the sockets or easing work in
normal mode for NUMA. By default, the Alternate RTID (Requestor
Transaction ID) Setting is set to Disabled.
Virtualization Technology Enables or disables the additional hardware capabilities provided for
virtualization. By default, the Virtualization Technology option is set to
Enabled.
Address Translation Service
(ATS)
Defines the Address Translation Cache (ATC) for devices to cache the
DMA transactions. This field provides an interface to a chipset's Address
Translation and Protection Table to translate DMA addresses to host
addresses. By default, the option is set to Enabled.
Adjacent Cache Line
Prefetch
Optimizes the system for applications that require high utilization of
sequential memory access. By default, the Adjacent Cache Line Prefetch
option is set to Enabled. You can disable this option for applications that
require high utilization of random memory access.
Hardware Prefetcher Enables or disables the hardware prefetcher. By default, the Hardware
Prefetcher option is set to Enabled.
DCU Streamer Prefetcher Allows you to enable or disable the Data Cache Unit (DCU) streamer
prefetcher. By default, the DCU Streamer Prefetcher option is set to
Enabled.
27
Menu Item Description
DCU IP Prefetcher Enables or disables the Data Cache Unit (DCU) IP prefetcher. By default,
the DCU IP Prefetcher option is set to Enabled.
Execute Disable Enables or disables the execute disable memory protection technology.
By default, the Execute Disable option is set to Enabled.
Logical Processor Idling Enables or disables the operating system capability to put logical
processors in the idling state in order to reduce power consumption. By
default, the option is set to Disabled.
Configurable TDP Allows reconfiguration of Thermal Design Power (TDP) to lower levels.
TDP refers to the maximum amount of power the cooling system is
required to dissipate.
X2Apic Mode Enables or disables the X2Apic mode.
Number of Cores per
Processor
Controls the number of enabled cores in each processor. By default, the
Number of Cores per Processor option is set to All.
Processor 64-bit Support Specifies if the processor(s) support 64-bit extensions.
Processor Core Speed Displays the maximum core frequency of the processor.
Processor Bus Speed Displays the bus speed of the processor.
NOTE: The processor bus speed option displays only when both
processors are installed.
Processor 1 NOTE: Depending on the number of installed CPUs, there may be
up to two processor listings. The following settings are displayed for
each processor installed in the system.
Family-Model-Stepping Displays the family, model and stepping of the processor as defined by
Intel.
Brand Displays the brand name reported by the processor.
Level 2 Cache Displays the total L2 cache.
Level 3 Cache Displays the total L3 cache.
Number of Cores Displays the number of cores per processor.
SATA Settings screen
You can use the SATA Settings screen to view the SATA settings of SATA devices and enable RAID on
your system.
To view the SATA Settings screen click System Setup Main Menu → System BIOS → SATA Settings.
Menu Item Description
Embedded SATA Enables the embedded SATA to be set to Off, ATA, AHCI, or RAID modes.
By default, the Embedded SATA option is set to AHCI.
Security Freeze Lock Sends Security Freeze Lock command to the Embedded SATA drives
during POST. This option is applicable only to ATA and AHCI mode.
Write Cache Enables or disables the command for Embedded SATA drives during
POST.
28
Menu Item Description
Port A Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port B Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port C Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port D Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port E Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
29
Menu Item Description
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port F Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port G Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port H Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port I Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Port J Sets the drive type of the selected device. For Embedded SATA settings
in ATA mode, set this field to Auto to enable BIOS support. Set it to OFF
to turn off BIOS support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
30
Menu Item Description
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for
removable media devices such as optical drives.
Boot Settings screen
You can use the Boot Settings screen to set the Boot mode to either BIOS or UEFI. It also allows you to
specify the boot order.
To view the Boot Settings screen click System Setup Main Menu → System BIOS → Boot Settings.
Menu Item Description
Boot Mode Enables you to set the boot mode of the system.
CAUTION: Switching the boot mode may prevent the system from
booting if the operating system is not installed in the same boot
mode.
NOTE: Setting this field to UEFI disables the BIOS Boot Settings
menu. Setting this field to BIOS disables the UEFI Boot Settings
menu.
If the operating system supports UEFI, you can set this option to UEFI.
Setting this field to BIOS allows compatibility with non-UEFI operating
systems. By default, the Boot Mode option is set to BIOS.
Boot Sequence Retry Enables or disables the Boot Sequence Retry feature. If this field is
enabled and the system fails to boot, the system reattempts the boot
sequence after 30 seconds. By default, the Boot Sequence Retry option
is set to Enabled.
Hard-Disk Failover Specifies which devices in the Hard-Disk Drive Sequence are attempted
in the boot sequence. When the option is Disabled, only the first hard
disk device in the list is attempted to boot. When set to Enabled, all hard
disk devices are attempted in order, as listed in the Hard-Disk Drive
Sequence. This option is not enabled for UEFI Boot Mode.
Boot Option Settings Configures the boot sequence and the boot devices.
Network Settings screen
You can use the Network Settings screen to modify PXE device settings. Network Settings are only
available in UEFI boot mode. BIOS does not control network settings in the BIOS boot mode. For BIOS
boot mode, the network settings are handled by the network controllers option ROM.
To view the Network Settings click System Setup Main Menu → System BIOS → Network Settings.
Menu Item Description
PXE Device n (n = 1 to 4) Enables or disables the device. When enabled, a UEFI boot option is
created for the device.
PXE Device n Settings (n = 1
to 4)
Allows you to control the configuration of the PXE device.
31
Integrated Devices screen details
The Integrated Devices screen allows you to view and configure the settings of all integrated devices
including the video controller, integrated RAID controller, and the USB ports.
In the System Setup Main Menu, click System BIOS → Integrated Devices.
Menu Item Description
USB 3.0 Setting Allows you to enable or disable the USB 3.0
support. Enable this option only if your operating
system supports USB 3.0. Disabling this allows
devices to operate at USB 2.0 speed. USB 3.0 is
disabled by default.
User Accessible USB Ports Allows you to enable or disable the USB ports.
Selecting Only Back Ports On disables the front
USB ports and selecting All Ports Off disables all
USB ports. The USB keyboard and mouse operates
during boot process in certain operating systems.
After the boot process is complete, the USB
keyboard and mouse do not work if the ports are
disabled.
NOTE: Selecting Only Back Ports On and All
Ports Off will disable the USB management
port and also restrict access to iDRAC
features.
Internal USB Port Allows you to enable or disable the internal USB
port. By default, the Internal USB Port option is set
to Enabled.
Integrated RAID Controller Enables or disables the integrated RAID controller.
By default, the option is set to Enabled.
Embedded NIC1 and NIC2 Allows you to enable or disable the Embedded
NIC1 and NIC2. If set to Disabled, the NIC may still
be available for shared network access by the
embedded management controller. Configure this
function using the NIC management utilities of the
system.
Embedded NIC3 and NIC4 Allows you to enable or disable the Embedded
NIC3 and NIC4 .If set to Disabled, the NIC may still
be available for shared network access by the
embedded management controller. Configure this
function using the NIC management utilities of the
system.
I/OAT DMA Engine Allows you to enable or disable the I/OAT option.
Enable only if the hardware and software supports
the feature.
Embedded Video Controller Allows you to enable or disable the Embedded
Video Controller. By default, the embedded video
controller is Enabled. If the Embedded Video
Controller is the only display capability in the
system (that is, no add-in graphics card is
installed), then the Embedded Video Controller is
32
automatically used as the primary display even if
the Embedded Video Controller setting is Disabled.
Current State of Embedded Video Controller Displays the current state of the Embedded Video
Controller. Current State of Embedded Video
Controller is a read only field, indicating the
current state for the Embedded Video Controller.
SR-IOV Global Enable Allows you to enable or disable the BIOS
configuration of Single Root I/O Virtualization (SR-
IOV) devices. By default, the SR-IOV Global Enable
option is set to Disabled.
OS Watchdog Timer If your system stops responding, this watchdog
timer aids in the recovery of your operating
system. When this field is set to Enabled, the
operating system is allowed to initialize the timer.
When is the field is set to Disabled (the default),
the timer will have no effect on the system.
Memory Mapped I/O above 4 GB Allows you to enable support for PCIe devices that
require large amounts of memory. By default, the
option is set to Enabled.
Slot Disablement Allows you to enable or disable the available PCIe
slots on your system. The Slot Disablement feature
controls the configuration of PCIe cards installed
in the specified slot. Slot disablement must be used
only when the installed peripheral card is
preventing booting into the operating system or
causing delays in system startup. If the slot is
disabled, both the Option ROM and UEFI driver are
disabled.
Serial Communication screen
You can use the Serial Communication screen to view the properties of the serial communication port.
To view the Serial Communication click System Setup Main Menu → System BIOS → Serial
Communication.
Menu Item Description
Serial Communication Selects serial communication devices (Serial Device 1 and Serial Device 2)
in the BIOS. BIOS console redirection can also be enabled and the port
address can be specified. By default, Serial Communication option is set
to Auto.
Serial Port Address Enables you to set the port address for serial devices. By default, the
Serial Port Address option is set to Serial Device 1=COM2, Serial Device
2=COM1
NOTE: You can use only Serial Device 2 for the Serial Over LAN
(SOL) feature. To use console redirection by SOL, configure the
same port address for console redirection and the serial device.
33
Menu Item Description
NOTE: Every time the system boots, the BIOS syncs the serial MUX
setting saved in iDRAC. The serial MUX setting can independently be
changed in iDRAC. Therefore, loading the BIOS default settings from
within the BIOS setup utility may not always revert this setting to the
default setting of Serial Device 1.
External Serial Connector You can associate the External Serial Connector to Serial Device 1, Serial
Device 2, or the Remote Access Device using this field.
NOTE: Only Serial Device 2 can be used for (Serial Over LAN) SOL.
To use console redirection by SOL, configure the same port address
for console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX
setting saved in iDRAC. The serial MUX setting can independently be
changed in iDRAC. Therefore, loading the BIOS default settings from
within the BIOS setup utility may not always revert this setting to the
default setting of Serial Device 1.
Failsafe Baud Rate Displays the failsafe baud rate for console redirection. The BIOS attempts
to determine the baud rate automatically. This failsafe baud rate is used
only if the attempt fails, and the value must not be changed. By default,
the Failsafe Baud Rate option is set to 115200.
Remote Terminal Type Sets the remote console terminal type. By default, the Remote Terminal
Type option is set to VT 100/VT 220.
Redirection After Boot Enables or disables the BIOS console redirection when the operating
system is loaded. By default, the Redirection After Boot option is set to
Enabled.
System Profile Settings screen
You can use the System Profile Settings screen to enable specific system performance settings such as
power management.
To view the System Profile Settings click System Setup Main Menu → System BIOS → System Profile
Settings.
Menu Item Description
System Profile Sets the system profile. If you set the System Profile option to a mode
other than Custom, the BIOS automatically sets the rest of the options.
You can only change the rest of the options if the mode is set to Custom.
By default, the System Profile option is set to Performance Per Watt
Optimized (DAPC). DAPC is Dell Active Power Controller.
NOTE: The following parameters are available only when the System
Profile is set to Custom.
CPU Power Management Sets the CPU power management. By default, the CPU Power
Management option is set to System DBPM (DAPC). DBPM is Demand-
Based Power Management.
Memory Frequency Sets the speed of the system memory. You can select Maximum
Performance, Maximum Reliability, or a specific speed.
Turbo Boost Enables or disables the processor to operate in turbo boost mode. By
default, the Turbo Boost option is set to Enabled.
34
Menu Item Description
Energy Efficient Turbo Enables or disables the Energy Efficient Turbo.
Energy Efficient Turbo (EET) is a mode of operation where a processor’s
core frequency is adjusted within the turbo range based on workload.
C1E Enables or disables the processor to switch to a minimum performance
state when it is idle. By default, the C1E option is set to Enabled.
C States Enables or disables the processor to operate in all available power states.
By default, the C States option is set to Enabled.
Collaborative CPU
Performance Control
Enables or disables the CPU power management. When set to Enabled,
the CPU power management is controlled by the OS DBPM and the
System DBPM (DAPC). By default, the option is set to Disabled.
Memory Patrol Scrub Sets the memory patrol scrub frequency. By default, the Memory Patrol
Scrub option is set to Standard.
Memory Refresh Rate Sets the memory refresh rate to either 1x or 2x. By default, the Memory
Refresh Rate option is set to 1x.
Uncore Frequency Selects the Processor Uncore Frequency.
Dynamic mode allows the processor to optimize power resources across
the cores and uncore during runtime. The optimization of the uncore
frequency to either save power or optimize performance is influenced by
the setting of the Energy Efficiency Policy.
Energy Efficient Policy Enables you to selects the Energy Efficient Policy.
The CPU uses the setting to manipulate the internal behavior of the
processor and determines whether to target higher performance or
better power savings.
Number of Turbo Boot
Enabled Cores for Processor
1
NOTE: If there are two processors installed in the system, you see an
entry for Number of Turbo Boost Enabled Cores for Processor 2.
Controls the number of turbo boost enabled cores for processor 1. By
default, the maximum number of cores is enabled.
Monitor/Mwait Enables the Monitor/Mwait instructions in the processor. By default, the
Monitor/Mwait option is set to Enabled for all system profiles, except
Custom.
NOTE: This option can be disabled only if the C States option in
Custom mode is disabled.
NOTE: When C States is enabled in Custom mode, changing the
Monitor/Mwait setting does not impact system power/performance.
System Security Settings screen
You can use the System Security screen to perform specific functions such as setting the system
password, setup password and disabling the power button.
To view the System Security click System Setup Main Menu → System BIOS → System Security Settings.
35
Menu Item Description
Intel AES-NI Improves the speed of applications by performing encryption and
decryption using the Advanced Encryption Standard Instruction Set and is
set to Enabled by default.
System Password Sets the system password. This option is set to Enabled by default and is
read-only if the password jumper is not installed in the system.
Setup Password Sets the setup password. This option is read-only if the password jumper
is not installed in the system.
Password Status Locks the system password. By default, the Password Status option is set
to Unlocked.
TPM Security NOTE: The TPM menu is available only when the TPM module is
installed.
Allows you to control the reporting mode of the Trusted Platform
Module (TPM). By default, the TPM Security option is set to Off. You can
only modify the TPM Status, TPM Activation , and Intel TXT fields if the
TPM Status field is set to either On with Pre-boot Measurements or On
without Pre-boot Measurements.
TPM Information Changes the operational state of the TPM. By default, the TPM Activation
option is set to No Change.
TPM Status Displays the TPM status.
TPM Command CAUTION: Clearing the TPM results in the loss of all keys in the
TPM. The loss of TPM keys may affect booting to the operating
system.
Clears all the contents of the TPM. By default, the TPM Clear option is set
to No.
Intel TXT Enables or disables the Intel Trusted Execution Technology (TXT). To
enable Intel TXT, Virtualization Technology must be enabled and TPM
Security must be Enabled with Pre-boot measurements. By default, the
Intel TXT option is set to Off
Power Button Enables or disables the power button on the front of the system. By
default, the Power Button option is set to Enabled.
NMI Button Enables or disables the NMI button on the front of the system. By default,
the NMI Button option is set to Disabled.
AC Power Recovery Sets how the system reacts after AC power is restored to the system. By
default, the AC Power Recovery option is set to Last.
AC Power Recovery Delay Sets how the system supports staggering of power up after AC power is
restored to the system. By default, the AC Power Recovery Delay option
is set to Immediate.
User Defined Delay (60s to
240s)
Sets the User Defined Delay when the User Defined option for AC Power
Recovery Delay is selected.
UEFI Variable Access Provides varying degrees of securing UEFI variables. When set to
Standard (the default) UEFI variables are accessible in the Operating
System per the UEFI specification. When set to Controlled, selected UEFI
variables are protected in the environment and new UEFI boot entries are
forced to be at the end of the current boot order.
36
Menu Item Description
Secure Boot Enables Secure Boot, where the BIOS authenticates each pre-boot image
using the certificates in the Secure Boot Policy. Secure Boot is disabled
by default.
Secure Boot Policy When Secure Boot policy is Standard, the BIOS uses the system
manufacturer’s key and certificates to authenticate pre-boot images.
When Secure Boot policy is Custom, the BIOS uses the user-defined key
and certificates. Secure Boot policy is Standard by default.
Secure Boot Policy
Summary
Displays the list of certificates and hashes that secure boot uses to
authenticate images.
Secure Boot Custom Policy Settings screen
Secure Boot Custom Policy Settings is displayed only when Secure Boot Policy is set to Custom.
In the System Setup Main Menu, click System BIOS → System Security → Secure Boot Custom Policy
Settings.
Menu Item Description
Platform Key Imports, exports, deletes, or restores the platform
key (PK).
Key Exchange Key Database Allows you to import, export, delete, or restore
entries in the Key Exchange Key (KEK) Database.
Authorized Signature Database Imports, exports, deletes, or restores entries in the
Authorized Signature Database (db).
Forbidden Signature Database Imports, exports, deletes, or restores entries in the
Forbidden Signature Database (dbx).
Miscellaneous Settings screen
You can use the Miscellaneous Settings screen to perform specific functions such as updating the asset
tag, and changing the system date and time.
To view the Miscellaneous Settings click System Setup Main Menu → System BIOS → Miscellaneous
Settings.
Menu Item Description
System Time Enables you to set the time on the system.
System Date Enables you to set the date on the system.
Asset Tag Displays the asset tag and enables you to modify it for security and
tracking purposes.
Keyboard NumLock Enables you to set whether the system boots with the NumLock enabled
or disabled. By default the Keyboard NumLock is set to On.
NOTE: This option does not apply to 84-key keyboards.
F1/F2 Prompt on Error Enables or disables the F1/F2 prompt on error. By default, F1/F2 Prompt
on Error is set to Enabled. The F1/F2 prompt also includes keyboard
errors.
Load Legacy Video Option
ROM
Enables you to determine whether the system BIOS loads the legacy
video (INT 10H) option ROM from the video controller. Selecting Enabled
37
Menu Item Description
in the operating system does not support UEFI video output standards.
This field is only for UEFI boot mode. You cannot set this to Enabled if
UEFI Secure Boot mode is enabled.
About Boot Manager
Boot Manager enables you to add, delete, and arrange boot options. You can also access System Setup
and boot options without restarting the system.
Entering Boot Manager
The Boot Manager screen allows you to select boot options and diagnostic utilities.
1. Turn on or restart your system.
2. Press <F11> when you see the message <F11> = Boot Manager.
If your operating system begins to load before you press <F11>, allow the system to finish booting,
and then restart your system and try again.
Boot Manager main menu
Menu Item Description
Continue Normal Boot The system attempts to boot to devices starting
with the first item in the boot order. If the boot
attempt fails, the system continues with the next
item in the boot order until the boot is successful
or no more boot options are found.
One Shot Boot Menu Takes you to the boot menu where you can select
a one time boot device to boot from.
Launch System Setup Enables you to access the System Setup.
Launch Lifecycle Controller Exits the Boot Manager and invokes the Lifecycle
Controller program.
System Utilities Launches system utilities menu such as system
diagnostics and UEFI shell.
About Dell Lifecycle Controller
Dell Lifecycle Controller allows you to perform useful tasks such as configuring BIOS and hardware
settings, deploying an operating system, updating drivers, changing RAID settings, and saving hardware
38
profiles. For more information about Dell Lifecycle Controller, see the documentation at dell.com/
esmmanuals.
Changing the boot order
You may have to change the boot order if you want to boot from a USB key or an optical drive. The
instructions given below may vary if you have selected BIOS for Boot Mode.
1. In the System Setup Main Menu, click System BIOS → Boot Settings.
2. Click Boot Option Settings → Boot Sequence.
3. Use the arrow keys to select a boot device, and use the <+> and <-> keys to move the device down
or up in the order.
4. Click Exit, click Yes to save the settings on exit.
Choosing the system boot mode
System Setup enables you to specify the boot mode for installing your operating system:
• BIOS boot mode (the default) is the standard BIOS-level boot interface.
• UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface
(UEFI) specifications that overlays the system BIOS.
To choose the system Boot Mode:
1. In System Setup click Boot Settings and select Boot Mode.
2. Select the Boot Mode you want the system to boot into.
NOTE: After the system boots in the specified boot mode, proceed to install your operating system
from that mode.
CAUTION: Trying to boot the operating system from the other boot mode will cause the system
to halt at startup.
NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS
and 32-bit operating systems do not support UEFI and can only be installed from the BIOS boot
mode.
NOTE: For the latest information on supported operating systems, go to dell.com/ossupport .
Assigning a system and setup password
Prerequisites
NOTE: The password jumper enables or disables the System Password and Setup Password
features..
You can assign a new System Password and Setup Password or change an existing System Password
and Setup Password only when the password jumper setting is Enabled and Password Status is
Unlocked.
If the password jumper setting is disabled, the existing System Password and Setup Password is deleted
and you need not provide the system password to boot the system.
39
About this task
To assign a System Password and Setup Password, follow the steps below:
Steps
1. To enter System Setup, press <F2> immediately after a power-on or reboot.
2. From the System Setup Main Menu, select System BIOS and press <Enter>.
The System BIOS screen is displayed.
3. On the System BIOS screen, select System Security and press <Enter>.
The System Security screen is displayed.
4. On the System Security screen, verify that Password Status is Unlocked.
5. Select System Password, enter your system password, and press <Enter> or <Tab>.
Use the following guidelines to assign the system password:
• A password can have up to 32 characters.
• The password can contain the numbers 0 through 9.
• Only the following special characters are allowed: space, (”), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`).
A message prompts you to re-enter the system password.
6. Re-enter the system password, and click OK.
7. Select Setup Password, enter your setup password and press <Enter> or <Tab>.
A message prompts you to re-enter the setup password.
8. Re-enter the setup password, and click OK.
9. Press <Esc> to return to the System BIOS screen. Press <Esc> again.
A message prompts you to save the changes.
NOTE: Password protection does not take effect until the system reboots.
Related Links
System board connectors
Using your system password to secure your system
Prerequisites
NOTE: If you have assigned a setup password, the system accepts your setup password as an
alternate system password.
Steps
1. Turn on or reboot your system.
2. Type your password and press <Enter>.
Next steps
When Password Status is Locked, type the password and press <Enter> when prompted at reboot.
If an incorrect system password is entered, the system displays a message and prompts you to re-enter
your password. You have three attempts to enter the correct password. After the third unsuccessful
attempt, the system displays an error message that the system has halted and must be powered down.
Even after you shut down and restart the system, the error message is displayed until the correct
password is entered.
40
NOTE: You can use the Password Status option in conjunction with the System Password and
Setup Password options to protect your system from unauthorized changes.
Deleting or changing an existing system and/or setup
password
Prerequisites
Ensure that the Password jumper is set to enabled and the Password Status is set to Unlocked before
attempting to delete or change the existing System and/or Setup password. You cannot delete or change
an existing System or Setup password if the Password Status is Locked.
Steps
1. To enter System Setup, press <F2> immediately after a power-on or restart.
2. In the System Setup Main Menu, select System BIOS and press <Enter>.
The System BIOS screen is displayed.
3. In the System BIOS Screen, select System Security and press <Enter>.
The System Security screen is displayed.
4. In the System Security screen, verify that Password Status is set to Unlocked.
5. Select System Password, alter or delete the existing system password and press <Enter> or <Tab>.
6. Select Setup Password, alter or delete the existing setup password and press <Enter> or <Tab>.
NOTE: If you change the System and/or Setup password, a message prompts you to re-enter
the new password. If you delete the System and/or Setup password, a message prompts you to
confirm the deletion.
7. Press <Esc> to return to the System BIOS screen. Press <Esc> again, and a message prompts you to
save the changes.
Operating with a setup password enabled
If Setup Password is Enabled, enter the correct setup password before modifying most of the System
Setup options.
If you do not enter the correct password in three attempts, the system displays the message
Invalid Password! Number of unsuccessful password attempts: <x> System Halted!
Must power down.
Even after you shut down and restart the system, the error message is displayed until the correct
password is entered. The following options are exceptions:
• If System Password is not Enabled and is not locked through the Password Status option, you can
assign a system password.
• You cannot disable or change an existing system password.
NOTE: You can use the Password Status option in conjunction with the Setup Password option to
protect the system password from unauthorized changes.
41
Embedded system management
The Dell Lifecycle Controller provides advanced embedded systems management throughout the
server’s lifecycle. The Lifecycle Controller can be started during the boot sequence and can function
independently of the operating system.
NOTE: Certain platform configurations may not support the full set of features provided by the
Lifecycle Controller.
For more information about setting up the Lifecycle Controller, configuring hardware and firmware, and
deploying the operating system, see the Lifecycle Controller documentation at dell.com/support/home.
iDRAC Settings utility
The iDRAC Settings utility is an interface to set up and configure the iDRAC parameters using UEFI. You
can enable or disable various iDRAC parameters using the iDRAC Settings Utility.
NOTE: Accessing some of the features on the iDRAC Settings utility requires the iDRAC Enterprise
License upgrade.
For more information on using iDRAC, see the iDRAC User's Guide at dell.com/esmmanuals.
Entering the iDRAC Settings utility
1. Turn on or restart the managed system.
2. Press <F2> during Power-on Self-test (POST).
3. In the System Setup Main Menu page, click iDRAC Settings.
The iDRAC Settings screen is displayed.
Changing the Thermal Settings
The iDRAC Settings utility enables you to select and customize the thermal control settings for your
system.
1. Enter the iDRAC Settings utility.
2. Under iDRAC Settings → Thermal → User Option, select between the following options:
• Default
• Maximum Exhaust Temperature
• Fan Speed Offset
NOTE: When the User Option is set to the default Auto setting, the user option cannot be
modified.
3. Set the Maximum Air Exhaust Temperature or the Fan Speed Offset fields.
4. Click Back → Finish → Yes.
42
4
Installing and removing system
components
Safety instructions
WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not
attempt to lift the system by yourself.
WARNING: Opening or removing the system cover while the system is powered on may expose
you to a risk of electric shock.
CAUTION: Do not operate the system without the cover for a duration exceeding five minutes.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: It is recommended that you always use a static mat and static strap while working on
components inside the system.
NOTE: To ensure proper operation and cooling, all bays in the system must be populated at all
times with either a module or with a blank.
Before working inside your system
1. Turn off the system, including any attached peripherals.
2. Disconnect the system from the electrical outlet and disconnect the peripherals.
3. If installed, remove the front bezel.
4. Remove the system cover.
Related Links
Removing the front bezel
Removing the system cover
After working inside your system
1. Install the system cover.
2. If applicable, install the front bezel.
3. Reconnect the system to its electrical outlet.
4. Turn the system on, including any attached peripherals.
43
Related Links
Installing the system cover
Installing the front bezel
Recommended tools
You need the following tools to perform the removal and installation procedures:
• Key to the front bezel lock. This is required only if you have a front bezel.
• #1 Phillips screwdriver
• #2 Phillips screwdriver
The following tools are required for assembling the cables for a DC power supply unit (PSU):
• AMP 90871-1 or Tyco Electronics 58433-3 or equivalent hand-crimping tool
• Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated
copper wire
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding).
Front bezel (optional)
Removing the front bezel
1. Unlock the bezel.
2. Lift the release latch next to the lock.
3. Rotate the left end of the bezel away from the front panel.
4. Unhook the right end of the bezel and pull the bezel away from the system.
44
1. bezel lock 2. front bezel
Installing the front bezel
1. Hook the right end of the bezel onto the chassis.
2. Fit the free end of the bezel onto the system.
3. Lock the bezel.
Figure 9. Removing and installing the front bezel
1. release latch 2. keylock
3. front bezel
Removing and installing the system cover
WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not
attempt to lift the system by yourself.
WARNING: Installing or removing the system cover when the system is on may expose you to a
risk of electric shock.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: Do not operate the system without the cover for a duration exceeding five minutes.
45
Removing the system cover
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
Steps
1. On top of the system, locate the latch release lock and rotate the lock to the unlocked position.
2. Lift the latch and slide the cover back. The system cover slides back and the tabs on the system cover
disengages from the slots on the chassis.
3. Hold the cover on both sides and lift the cover away from the system.
Figure 10. Opening and closing the system
1. system cover 2. latch
3. latch release lock
Next steps
1. Install the system cover.
2. Follow the procedure listed in After working inside your system..
Related Links
Installing the system cover
Installing the system cover
Prerequisites
Ensure that you read the Safety instructions.
46
Steps
1. Align the slots of the system cover with the tabs on the chassis.
2. Press the cover release latch, and push the cover toward the front of the chassis until the latch locks
into place.
3. Turn the cover latch release lock clockwise to the locked position.
Next steps
1. Install the bezel (optional).
2. Follow the procedure listed in After working inside your system.
Related Links
Installing the front bezel
Inside the system
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: Components that are hot-swappable are marked orange, and touch-points on the
components are marked blue.
47
Figure 11. Inside the System—Redundant Power Supply Unit Chassis
1. control-panel board 2. hard-drive backplane
3. cooling fan (5) 4. power-interposer board
5. power supply (redundant) 6. optional expansion-card riser
7. processor (2) 8. DIMM (12)
48
Figure 12. Inside the System—Non-Redundant Power Supply Unit Chassis
1. control-panel board 2. hard-drive backplane
3. cooling fans (5) 4. power supply ( non redundant)
5. optional expansion-card riser 6. processor (2)
7. DIMM (12)
Cooling shroud
Removing the cooling shroud
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
49
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. If applicable, disconnect the power or data cables from expansion card (s).
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full-
length card.
4. If installed, remove the expansion-card riser
CAUTION: Never operate your system with the cooling shroud removed. The system may get
overheated quickly, resulting in shutdown of the system and loss of data.
Steps
Hold and lift the cooling shroud away from the system.
Figure 13. Removing and installing the cooling shroud
1. cooling shroud 2. chassis intrusion switch
3. chassis intrusion switch connector on
system board 4. cooling shroud alignment slots
5. cooling shroud alignment pins
Next steps
1. Install the optional PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full-length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the (optional) expansion-card riser
Removing an expansion card from the expansion-card riser
Installing an expansion card into the expansion-card riser
50
Installing the (optional) expansion-card riser
Installing the cooling shroud
Installing the cooling shroud
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: For proper seating of the cooling shroud in the chassis, ensure that the cables inside the
system are routed along the chassis wall and secured using the cable securing bracket.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
Steps
1. Align the tabs on the cooling shroud with the securing holes at the back of the chassis.
2. Lower the cooling shroud into the chassis until it is firmly seated.
Next steps
1. Install the optional PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. If applicable open the expansion-card latch on the cooling shroud to secure the full-length
expansion card.
4. Follow the procedure listed in After working inside your system.
Related Links
Installing an expansion card into the expansion-card riser
Installing the (optional) expansion-card riser
System memory
Your system supports DDR4 registered DIMMs (RDIMMs). It supports DDR4 voltage specifications.
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
Memory bus operating frequency can be 2133 MT/s, 1866 MT/s, 1600 MT/s, or 1333 MT/s depending on:
• System profile selected (for example, Performance Optimized, Custom, or Dense Configuration
Optimized)
• Maximum supported DIMM frequency of the processors
Your system contains 12 memory sockets split into four sets— two sets of 4 sockets and two sets of 2
sockets each. DIMMs in sockets A1 to A8 are assigned to processor 1 and DIMMs in sockets B1 to B4 are
assigned to processor 2. Each 4-socket set is organized into two channels and each 2–socket set is
organized into one channel. In each channel of the 4-socket set, the release levers of the first socket are
marked white and those of the second socket are marked black. In the 2-socket set, each release lever is
marked white.
51
Figure 14. Memory socket locations
Memory channels are organized as follows:
Processor 1 channel 0: slots A1 and A5
channel 1: slots A2 and A6
channel 2: slots A3 and A7
channel 3: slots A4 and A8
Processor 2 channel 0: slot B1
channel 1: slot B2
channel 2: slot B3
52
channel 3: slot B4
The following table shows the memory populations and operating frequencies for the supported
configurations.
DIMM Type DIMMs Populated/
Channel Operating Frequency (in
MT/s) Maximum DIMM Rank/Channel
1.2 V
RDIMM 12133, 1866, 1600, and 1333 Single rank or dual rank
2
General memory module installation guidelines
Your system supports Flexible Memory Configuration, enabling the system to be configured and run in
any valid chipset architectural configuration. The following are the recommended guidelines for installing
memory modules:
• x4 and x8 DRAM based DIMMs can be mixed. For more information, see Mode-specific guidelines.
• Up to two dual- or single-rank RDIMMs can be populated per channel.
• Populate DIMM sockets only if a processor is installed. For single-processor systems, sockets A1 to A8
are available. For dual-processor systems, sockets A1 to A8 and sockets B1 to B4 are available.
• Populate all sockets with white release levers first, and then all the sockets with black release levers.
• When mixing memory modules with different capacities, populate the sockets with memory modules
with highest capacity first. For example, if you want to mix 4 GB and 8 GB DIMMs, populate 8 GB
DIMMs in the sockets with white release levers and 4 GB DIMMs in the sockets with black release
levers.
• In a dual-processor configuration, the memory configuration for each processor should be identical
through the first eight slots. For example, if you populate socket A1 for processor 1, then populate
socket B1 for processor 2, and so on.
• Memory modules of different capacities can be mixed provided other memory population rules are
followed (for example, 4 GB and 8 GB memory modules can be mixed).
• Mixing of more than two DIMM capacities in a system is not supported.
• Populate two DIMMs per processor (one DIMM per channel) at a time to maximize performance.
Mode-specific guidelines
Four memory channels are allocated to each processor. The allowable configurations depend on the
memory mode selected.
NOTE: You can mix x4 and x8 DRAM based DIMMs to support RAS features. However, all guidelines
for specific RAS features must be followed. x4 DRAM based DIMMs retain Single Device Data
Correction (SDDC) in memory optimized (independent channel) mode. x8 DRAM based DIMMs
require Advanced ECC mode to gain SDDC.
The following sections provide additional slot population guidelines for each mode:
Advanced ECC (lockstep)
Advanced ECC mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This
protects against single DRAM chip failures during normal operation.
Memory installation guidelines:
53
• Memory modules must be identical in size, speed, and technology.
• DIMMs installed in memory sockets with white release levers must be identical and similar rule applies
for sockets with black release levers. This ensures that identical DIMMs are installed in matched pairs -
for example, A1 with A2, A3 with A4, A5 with A6, and so on.
NOTE: Advanced ECC with Mirroring is not supported.
Memory optimized (independent channel) mode
This mode supports SDDC only for memory modules that use x4 device width, and the mode does not
impose any specific slot population requirements.
Memory sparing
NOTE: To use memory sparing, this feature must be enabled in the System Setup.
In this mode, one rank per channel is reserved as a spare. If persistent correctable errors are detected on
a rank, the data from this rank is copied to the spare rank and the failed rank is disabled.
With memory sparing enabled, the system memory available to the operating system is reduced by one
rank per channel. For example, in a dual-processor configuration with sixteen 4 GB dual-rank DIMMs, the
available system memory is: 3/4 (ranks/channel) × 16 (DIMMs) × 4 GB = 48 GB, and not 16 (DIMMs) × 4
GB = 64 GB.
NOTE: Memory sparing does not offer protection against a multi-bit uncorrectable error.
NOTE: Both Advanced ECC/Lockstep and Optimizer modes support Memory Sparing.
Sample memory configurations
The following tables show sample memory configurations for one and two processor configurations that
follow the appropriate memory guidelines.
NOTE: 1R and 2R in the following tables indicate single- and dual-rank DIMMs respectively.
Table 1. Memory configurations—single processor
System
Capacity (in
GB)
DIMM Size
(in GB) Number of
DIMMs DIMM Rank,
Organization, and
Frequency
DIMM Slot Population
4 4 1 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1
8 4 2 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2
16 4 4 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2, A3, A4
8 2 2R, x8, 2133 MT/s,
2R, x8, 1866 MT/s
A1, A2
54
System
Capacity (in
GB)
DIMM Size
(in GB) Number of
DIMMs DIMM Rank,
Organization, and
Frequency
DIMM Slot Population
24 4 6 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6
48 8 6 2R, x8, 2133 MT/s,
2R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6
96 16 6 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s
A1, A2, A3, A4, A5, A6
128 16 8 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s,
A1, A2, A3, A4, A5, A6, A7, A8
192 32 6 RDIMM, 2R, x4, 2133
MT/s
RDIMM, 2R, x4, 1866
MT/s
A1, A2, A3, A4, A5, A6
Table 2. Memory configurations—two processors
System
Capacity (in
GB)
DIMM Size (in
GB) Number of
DIMMs DIMM Rank,
Organization, and
Frequency
DIMM Slot Population
16 4 4 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2, B1, B2
32 4 8 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2, A3, A4, B1, B2, B3, B4
64 8 8 2R, x8, 2133 MT/s,
2R, x8, 1866 MT/s
A1, A2, A3, A4, B1, B2, B3, B4
96 8 12 2R, x8, 2133 MT/s,
2R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6,A7,A8, B1,
B2, B3, B4
128 16 8 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s
A1, A2, A3, A4, B1, B2, B3, B4
160 16 and 8 12 2R, x4, 2133 MT/s,
2R, x8, 2133 MT/s,
2R, x4, 1866 MT/s
A1, A2, A3, A4, A5, A6,A7,A8, B1,
B2, B3, B4
55
System
Capacity (in
GB)
DIMM Size (in
GB) Number of
DIMMs DIMM Rank,
Organization, and
Frequency
DIMM Slot Population
2R, x8, 1866 MT/s NOTE: 16 GB DIMMs must
be installed in slots
numbered A1, A2, A3, A4,
B1, B2, B3, and B4 and 8
GB DIMMs must be
installed in slots A5, A6, A7,
and A8.
192 16 12 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s
A1, A2, A3, A4, A5, A6,A7,A8, B1,
B2, B3, B4
384 32 12 RDIMM, 2R, x4, 2133
MT/s
RDIMM, 2R, x4, 1866
MT/s
A1, A2, A3, A4, A5, A6,A7,A8, B1,
B2, B3, B4
Removing a memory module
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full-
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser.
WARNING: The memory modules are hot to the touch for some time after the system has been
powered down. Allow time for the memory modules to cool before handling them. Handle the
memory modules by the card edges and avoid touching the components or metallic contacts on
the memory module.
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any
memory socket that is not occupied. Remove memory-module blanks only if you intend to install
memory modules in those sockets.
Steps
1. Locate the appropriate memory module socket.
CAUTION: Handle each memory module only by the card edges, making sure not to touch
the middle of the memory module or metallic contacts.
2. To release the memory module from the socket, simultaneously press the ejectors on both ends of
the memory-module socket.
56
3. Lift the memory module out of the system.
Figure 15. Removing and installing a memory module
1. memory-module 2. memory-module socket
3. memory module socket ejector (2)
Next steps
1. If you are removing the memory module permanently, install a memory module blank.
2. If applicable, install the PCIe expansion-card riser.
3. If applicable, connect the required power or data cables to the expansion card(s).
4. Reinstall the cooling shroud.
5. If applicable open the expansion-card latch on the cooling shroud to secure the full-length
expansion card.
6. Follow the procedure listed in After working inside your system.
Related Links
Removing the (optional) expansion-card riser
Removing an expansion card from the expansion-card riser
Removing the cooling shroud
Installing memory modules
Installing an expansion card into the expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
57
Installing memory modules
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. If applicable, remove the PCIe expansion-card riser
4. Remove the cooling shroud.
WARNING: The memory modules are hot to the touch for some time after the system has been
powered down. Allow time for the memory modules to cool before handling them. Handle the
memory modules by the card edges and avoid touching the components or metallic contacts on
the memory module.
Steps
1. Locate the appropriate memory-module socket.
CAUTION: Handle each memory module only by the card edges, making sure not to touch
the middle of the memory module or metallic contacts.
2. If a memory module or a memory-module blank is installed in the socket, remove it.
NOTE: Retain the removed memory-module blank(s) for future use.
CAUTION: To prevent damage to the memory module or the memory-module socket during
installation, do not bend or flex the memory module; insert both ends of the memory module
simultaneously.
3. Align the edge connector of the memory module with the alignment key of the memory module
socket, and insert the memory module in the socket.
NOTE: The memory-module socket has an alignment key that allows you to install the memory
module in the socket in only one orientation.
CAUTION: Do not apply pressure at the center of the memory module; apply pressure at both
ends of the memory module evenly.
4. Press the memory module with your thumbs until the socket levers firmly click into place.
58
Figure 16. Installing the memory module
1. memory module 2. alignment key
3. memory-module socket ejector (2)
When the memory module is properly seated in the socket, the levers on the memory module socket
align with the levers on the other sockets that have memory modules installed.
5. Repeat steps 3 and 4 of this procedure to install the remaining memory modules.
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. Reinstall the cooling shroud.
3. Follow the procedure listed in After working inside your system.
4. Press <F2> to enter System Setup, and check the System Memory setting.
The system should have already changed the value to reflect the installed memory.
5. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat
steps 2 and 3 of Removing a memory module procedure, checking to ensure that the memory
modules are firmly seated in their sockets.
6. Run the system memory test in the system diagnostics.
Related Links
Removing the (optional) expansion-card riser
Removing an expansion card from the expansion-card riser
Removing the cooling shroud
Installing an expansion card into the expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
59
Hard drives
Your system supports up to eight 3.5 inch or 2.5 inch hot-swappable hard disk drives/SSDs.
All hard drives connect to the system board through the hard-drive backplane. Hot-swappable hard
drives are supplied in hot-swappable hard-drive carriers that fit in the hard-drive slots.
CAUTION: Before attempting to remove or install a hard drive while the system is running, see the
documentation for the storage controller card to ensure that the host adapter is configured
correctly to support hot-swap hard drive removal and insertion.
CAUTION: Do not turn off or reboot your system while the hard drive is being formatted. Doing
so can cause a hard drive failure.
NOTE: Use only hard drives that have been tested and approved for use with the hard-drive
backplane.
When you format a hard drive, allow enough time for the formatting to be completed. Be aware that
high-capacity hard drives can take a number of hours to format.
Removing a hot-swap hard drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. If installed, remove the front bezel.
3. Using the management software, prepare the hard drive for removal. For more information, see the
documentation for the storage controller.
If the hard drive is online, the green activity/fault indicator flashes as the drive is turned off. You can
remove the hard-drive when the hard-drive indicators turn off.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive
installation. See the documentation supplied with your operating system.
Steps
1. Press the release button to open the hard-drive carrier release handle.
2. Slide the hard-drive carrier out of the hard-drive slot.
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-
drive blanks installed.
3. If you are not replacing the hard drive immediately, insert a hard-drive blank in the empty hard-drive
slot.
60
Figure 17. Removing and installing a hot-swap hard drive
1. release button 2. hard-drive carrier
3. hard-drive carrier handle
Next steps
If removed, install the front bezel.
Related Links
Removing the front bezel
Installing the front bezel
Installing a hot-swap hard drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. If applicable, remove the front bezel.
CAUTION: Use only hard drives that have been tested and approved for use with the hard-drive
backplane.
CAUTION: Combining SAS and SATA hard drives in the same RAID volume is not supported.
CAUTION: When installing a hard drive, ensure that the adjacent drives are fully installed.
Inserting a hard-drive carrier and attempting to lock its handle next to a partially installed carrier
can damage the partially installed carrier's shield spring and make it unusable.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive
installation. See the documentation supplied with your operating system.
61
CAUTION: When a replacement hot-swappable hard drive is installed and the system is powered
on, the hard drive automatically begins to rebuild. Make absolutely sure that the replacement
hard drive is blank or contains data that you wish to have over-written. Any data on the
replacement hard drive is immediately lost after the hard drive is installed.
Steps
1. If a hard-drive blank is installed in the hard-drive slot, remove it.
2. Install a hard drive in the hard-drive carrier.
3. Press the release button on the front of the hard-drive carrier and open the hard-drive carrier handle.
4. Insert the hard-drive carrier into the hard-drive slot until the carrier connects with the backplane.
5. Close the hard-drive carrier handle to lock the hard drive in place.
Next steps
Install the optional front bezel.
1. Follow the procedure listed in After working inside your system.
2. Install the optional front bezel.
Related Links
Removing the front bezel
Installing a hot-swap hard drive
Installing the front bezel
Removing a 3.5 inch hard-drive blank
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have drive blanks
installed.
1. Ensure that you read the Safety instructions.
2. If installed, remove the front bezel.
Steps
Press the release button and slide the blank out of the hard-drive slot.
62
Figure 18. Removing and installing a 3.5 inch hard-drive blank
1. hard-drive blank 2. release button
Next steps
If applicable, install the front bezel.
Related Links
Removing the front bezel
Installing the front bezel
Installing a 3.5 inch hard-drive blank
Prerequisites
1. Ensure that you read the Safety instructions.
2. If applicable, remove the front bezel.
Steps
Insert the hard-drive blank into the hard-drive slot following the sequence in the image below and
push the hard-drive blank until the release button clicks into place.
63
Figure 19. Hard-drive blank installation sequence
Next steps
If applicable, install the front bezel.
Related Links
Removing the front bezel
Installing the front bezel
Removing a 2.5 inch hard drive from a 3.5 inch hard-drive adapter
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Keep the #2 Phillips screwdriver ready.
NOTE: A 2.5 inch hard drive is installed in a 3.5 inch hard-drive adapter, which is then installed in the
3.5 inch hard-drive carrier.
Steps
1. Remove the screws from the side of the 3.5 inch hard-drive adapter.
2. Remove the hard drive from the hard-drive adapter.
64
Installing a 2.5 inch hard drive into a 3.5 inch hard-drive adapter
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Keep the #2 Phillips screwdriver ready.
Steps
1. Align the screw holes on the 2.5 inch hard drive with the screw holes on the 3.5 inch hard-drive
adapter.
2. Install the screws to secure the hard drive to the hard-drive adapter.
Figure 20. Removing and installing a 2.5 inch hard drive into a 3.5 inch hard-drive adapter
1. 2.5 inch hard drive 2. 3.5 inch hard-drive adapter
3. screw (2)
Removing a hard-drive adapter from a hard-drive carrier
Prerequisites
1. Ensure that you read the Safety instructions.
2. Keep the #2 Phillips screwdriver ready.
Steps
1. Remove the screws from the slide rails on the hard-drive carrier.
2. Lift the hard-drive adapter out of the hard-drive carrier.
65
Installing a hard-drive adapter into a hard-drive carrier
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Keep the #2 Phillips screwdriver ready.
Steps
1. Insert the hard-drive adapter into the hard-drive carrier with the connector end of the hard drive
toward the back of the hard-drive carrier.
2. Align the screw holes on the hard drive with the holes on the hard-drive carrier.
3. Install the screws to secure the hard drive to the hard-drive carrier.
Figure 21. Removing and installing a hard-drive adapter into a 3.5 inch hard-drive carrier
1. 3.5 inch hard-drive carrier 2. screw (5)
3. hard-drive adapter 4. 2.5 inch hard drive
Removing a hard drive from a hard-drive carrier
Prerequisites
1. Keep the #2 Phillips screwdriver ready.
2. Remove the hard-drive carrier from the system.
Steps
1. Remove the screws from the slide rails on the hard-drive carrier.
2. Lift the hard drive out of the hard-drive carrier.
66
Figure 22. Removing and installing a hard drive into a hard-drive carrier
1. screw (4) 2. hard drive
3. hard-drive carrier
Installing a hard drive into a hard-drive carrier
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Keep the #2 Phillips screwdriver ready.
Steps
1. Insert the hard drive into the hard-drive carrier with the connector end of the hard drive toward the
back of the hard-drive carrier.
2. Align the screw holes on the hard drive with the screw holes on the hard-drive carrier.
When aligned correctly, the back of the hard drive is flush with the back of the hard-drive carrier.
3. Attach the screws to secure the hard drive to the hard-drive carrier.
Optical drive (optional)
Removing the optical drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
67
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
Steps
1. Disconnect the power/data cable from the back of the optical drive.
NOTE: Note the routing of the power/data cable as you remove them from the system board
and drive. You must route these cables properly when you replace them to prevent them from
being pinched or crimped.
2. Press down and push the blue release tab toward the front of the system.
3. Slide the optical drive out of the system until it is free of the drive bay.
Figure 23. Removing and installing the optical drive
1. optical drive 2. power cable
3. data cable 4. release tab
Next steps
1. If you are not adding a new optical drive, install the optical drive blank.
2. Install the optional front bezel
3. Follow the procedure listed in After working inside your system.
Installing the optical drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
68
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
Steps
1. If installed, remove the optical drive blank, and then press the blue release tab at the back of the
blank and push the blank out of the system.
2. Align the optical drive with the optical drive slot on the front of the chassis.
3. Slide the optical drive into the slot until the latch snaps into place.
4. Connect the power/data cable to the back of the drive.
5. Route the power/data cable through the cable routing guides on the system chassis.
Next steps
1. Follow the procedure listed in After working inside your system.
Cooling fans
Your system supports five cooling fans. A fan blank is pre-installed on the first cooling fan slot (FAN1).
NOTE: Hot-swap removal or installation of the fans is not supported.
NOTE: Each fan is listed in the system’s management software, referenced by the respective fan
number. If there is a problem with a particular fan, you can easily identify and replace the proper fan
by noting the fan numbers on the cooling fan assembly.
Listed below is the Fan configuration table which lists out the various fan configurations based on the
CPU configuration in the server.
Table 3. Fan configuration table
CPU Type CPU 1 CPU 2 PSU Type FAN1 FAN2 FAN3 FAN4 FAN5 FAN6
55W-120W
Y N Redundant /
Cabled
N Y Y Y Y N
Y Y Redundant /
Cabled
N Y Y Y Y Y
Removing a cooling fan
Prerequisites
WARNING: Opening or removing the system cover when the system is ON may expose you to a
risk of electric shock. Exercise utmost care while removing or installing cooling fans.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: The procedure for removing each cooling fan is the same.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
69
3. If applicable, remove the expansion-card riser.
4. Remove the cooling shroud.
Steps
1. Remove the fan cable connector from the system board by pressing the release tab on the system
board end of the connector, and lifting it away from the system board.
2. Free the cable from the cable holders on the fan bracket.
3. Press the release tab on the cooling fan and lift the fan away from the chassis.
Figure 24. Removing and installing a cooling fan
1. cooling fans (5) 2. cooling fan release tab
3. cooling fan cable connector 4. cooling fan connector on the system
board
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. Reinstall the cooling shroud.
3. Follow the procedure listed in After working inside your system.
70
Installing a cooling fan
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
Steps
1. Align the fan with the cable end of the fan toward the system board connector.
2. Lower the fan into the fan bracket until it clicks into position.
3. Connect the fan's power cable to the corresponding power connector on the system board.
4. Route the cable through the cable holders on the fan bracket.
Next steps
Follow the procedure listed in After working inside your system.
Internal USB memory key (optional)
An optional USB memory key installed inside your system can be used as a boot device, security key, or
mass storage device. The USB connector must be enabled by the Internal USB Port option in the
Integrated Devices screen of the System Setup.
To boot from the USB memory key, configure the USB memory key with a boot image, and then specify
the USB memory key in the boot sequence in the System Setup.
NOTE: To locate the internal USB connector (INT_USB) on the system board, see System board
connectors.
Replacing the internal USB key
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. If applicable, remove the PCIe expansion-card riser
4. If applicable, remove the full length PCIe expansion card.
5. Remove the cooling shroud.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the USB connector/USB key on the system board.
71
NOTE: To locate the internal USB connector on the system board, see System board
connectors.
2. If installed, remove the USB key.
3. Insert the new USB key into the USB connector.
Figure 25. Replacing the internal USB key
1. USB memory key 2. USB memory key connector
Next steps
1. If applicable, install the full length PCIe expansion card.
2. If applicable, install the PCIe expansion-card riser.
3. Reinstall the cooling shroud.
4. Follow the procedure listed in After working inside your system.
5. While booting, press <F2> to enter the System Setup and verify that the USB key is detected by the
system.
Related Links
Removing the (optional) expansion-card riser
Removing an expansion card from the expansion-card riser
Removing the cooling shroud
Installing an expansion card into the expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Expansion cards and expansion-card riser (optional)
NOTE: A missing or an unsupported expansion-card riser logs an SEL event. It does not prevent
your system from powering on and no BIOS POST message or F1/F2 pause is displayed.
72
Expansion-card installation guidelines
Your system supports PCI Express Generation 2 and Generation 3 expansion cards.
Use the following table as a guide for installing expansion cards to ensure proper cooling and mechanical
fit. The expansion cards with the highest priority must be installed first using the slot priority indicated. All
other expansion cards must be installed in card priority and slot priority order.
Table 4. Expansion card slots available on system board only
Location PCIe
slot Processor connection Height Length Link
width Slot
width
System board 1 Processor 2 Low
Profile
Half
Length
x8 x8
System board 2 Processor 1 Low
Profile
Half
Length
x16 x16
System board 3 Processor 1 Low
Profile
Half
Length
x16 x16
System board 4 Platform Controller Hub
(Mapped to Processor 1)
Low
Profile
Half
Length
x1 x1
System board 5 Platform Controller Hub
(Mapped to Processor 1)
Low
Profile
Half
Length
x4 x8
Table 5. Expansion card slots available on system board and optional expansion-card riser
Location PCIe
slot Processor connection Height Length Link
width Slot
width
Expansion-card riser 1 Processor 1 Full height Full
Length
x16 x16
Expansion-card riser 2 Processor 1 Full height Half
Length
x8 x8
System board 3 Processor 1 Low
Profile
Half
Length
x16 x16
System board 4 Platform Controller Hub
(Mapped to Processor 1)
Low
Profile
Half
Length
x1 x1
System board 5 Platform Controller Hub
(Mapped to Processor 1)
Low
Profile
Half
Length
x4 x8
NOTE: The optional expansion card riser is installed on PCIe slot 2 on the system board.
NOTE: When your system is installed with the optional expansion card riser in PCIe slot 2 on the
system board, you cannot install an expansion card in PCIe slot 1 of the system board.
NOTE: When x16 card installed in PCIe Slot 1 on expansion card riser the PCIe Slot 2 on the
expansion card will not function. The expansion card riser can be used only with two x8 PCIe cards
or with one x16 PCIe card on PCIE slot 1.
73
NOTE: Only slots 1, 2 and 3 support Generation 3 PCIe expansion cards.
NOTE: The expansion cards are not hot-swap.
Table 6. Expansion-card installation priority on system board only
Card Priority Category Slot Priority Max Allowed
1 GPU NA 0
2RAID Integrated storage Integrated Slot 1
RAID External storage 3,2,1 3
3 40G NICs 3,2,1 3
4 FC16 HBA 3,2,1 3
5 10Gb NICs 3,2,1,5 4
6 FC8 HBA 3,2,1,5 4
7
1Gb NICs (Broadcom Dual
Port)
3,2,1,5,4 5
1Gb NICs 3,2,1,5 4
8 Non-RAID 3,2,1 3
Table 7. Expansion-card installation priority on system board and optional expansion-card riser
Card Priority Category Slot Priority Max Allowed
1 GPU 1 1
2 RAID Integrated storage Integrated Slot 1
3
RAID External storage (Low
profile)
3 1
RAID External storage (Full
height)
2,1 2
440G NICs (Low profile) 3 1
40G NICs (Full height) 2,1 2
5FC16 HBA (Low profile) 3 1
FC16 HBA (Full height) 2,1 2
610Gb NICs (Low profile) 3,5 2
10Gb NICs (Full height) 2,1 2
7 FC8 HBA (Low profile) 3,5 2
FC8 HBA (Full height) 2,1 2
8
1Gb NICs (Low profile)
(Broadcom Dual Port)
3,5,4 3
1Gb NICs (Low profile) 3,5 2
74
Card Priority Category Slot Priority Max Allowed
1Gb NICs (Full height) 2,1 2
9Non-RAID (Low profile) 3 1
Non-RAID (Full height) 2,1 2
Removing an expansion card from the system board
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. If installed, disconnect the data / power cables from the expansion card.
2. Pull the expansion card retention latch lock and lift the latch up to open it.
3. Hold the expansion card by its edge, pull the card up to remove it from the expansion card
connector and out of the system.
4. If the expansion card is not going to be replaced, install a filler bracket by performing the following
steps:
a. Align the slot on the filler bracket with the tab on the expansion card slot.
b. Press the expansion card latch till the filler bracket locks into place.
NOTE: Filler brackets must be installed over empty expansion-card slots to maintain FCC
certification of the system. The brackets also keep dust and dirt out of the system and aid in
proper cooling and airflow inside the system.
75
1. expansion card retention latch lock 2. expansion card retention latch
3. expansion card 4. expansion card connector
Next steps
1. If applicable, connect the data / power cables to the expansion card.
2. Follow the procedure listed in After working inside your system.
Installing an expansion card on the system board
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Unpack the expansion card and prepare it for installation.
For instructions, see the documentation accompanying the card.
2. Open the expansion card retention latch.
3. If you are installing a new card, remove the filler bracket.
76
NOTE: Keep this bracket in case you need to remove the expansion card. Filler brackets must
be installed in empty expansion-card slots to maintain FCC certification of the system. The
brackets also keep dust and dirt out of the system and aid in proper cooling and airflow inside
the system.
4. Holding the card by its edges, position the card so that the card’s edge connector aligns with the
expansion card connector.
5. Insert the card’s edge connector firmly into the expansion card connector until the card is fully
seated.
6. Close the expansion card retention latch by pushing the latch down until the latch snaps into place.
7. Connect any cables to the expansion card.
Next steps
1. Install the expansion card holder.
2. Follow the procedure listed in After working inside your system.
Removing the (optional) expansion-card riser
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
Steps
Holding the touch points, lift the expansion-card riser from the riser connector on the system board.
77
Figure 26. Removing and installing the expansion card riser
1. expansion-card riser cage 2. riser guide on riser cage
3. riser guide on chassis
Next steps
1. If applicable, install an expansion card on the riser.
2. If applicable, reinstall the expansion-card riser.
3. Install the cooling shroud.
4. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Installing an expansion card into the expansion-card riser
Installing the cooling shroud
Installing the (optional) expansion-card riser
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. If applicable, reinstall the expansion card(s) into the expansion-card riser.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
78
Steps
1. Align the expansion-card riser with the PCIe connector on the system board and the riser guides on
the system board and chassis.
2. Lower the expansion-card riser into place until the expansion-card riser is fully seated in the
connector.
Next steps
1. Follow the procedure listed in After working inside your system.
2. Install any device drivers required for the expansion-card as described in the documentation for the
card.
Related Links
Installing an expansion card into the expansion-card riser
Removing an expansion card from the expansion-card riser
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. Disconnect any cables connected to the expansion card.
5. Remove the expansion card riser out of the server.
Steps
1. Press the expansion-card retention latch down and turn the latch counterclockwise to open.
2. If you want to remove the expansion card permanently, install a metal filler bracket over the empty
expansion slot opening and close the expansion-card latch.
3. Close the expansion-card retention latch.
NOTE: You must install a filler bracket over an empty expansion slot to maintain Federal
Communications Commission (FCC) certification of the system. The brackets also keep dust
and dirt out of the system and aid in proper cooling and airflow inside the system.
79
Figure 27. Removing and installing an expansion card from the expansion-card riser
1. expansion-card riser 2. expansion-card riser cage
3. expansion-card retention latch 4. expansion card
Figure 28. Removing and installing a full height, full length expansion card from the expansion-card
riser
1. full height, full length expansion card
latch (on cooling shroud) 2. full height, full length expansion card
3. expansion card riser cage 4. expansion card retention latch
80
Next steps
1. If applicable, install an expansion card.
2. Install the expansion-card riser.
3. Install the cooling shroud.
4. If applicable, open the expansion-card latch on the cooling shroud to support a full length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing an expansion card into the expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Installing an expansion card into the expansion-card riser
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable close the expansion-card latch on the cooling shroud to release the ful -
length card.
4. Remove the expansion-card riser.
5. Unpack the expansion card and prepare it for installation.
NOTE: For instructions, see the documentation accompanying the expansion card.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Press the expansion-card retention latch and rotate the latch clockwise.
2. Holding the card by its edges, position the card so that the card’s edge connector aligns with the
expansion card connector.
3. Insert the card’s edge connector firmly into the expansion card connector until the card is fully
seated.
4. Close the expansion-card retention latch.
5. If applicable, close the expansion-card latch on the cooling shroud.
Next steps
1. If applicable, install an expansion card.
2. Install the expansion-card riser.
3. If applicable, connect the required power or data cables to the expansion card.
4. Install the cooling shroud.
81
5. If applicable press the expansion-card latch on the cooling shroud to secure the expansion-card in
position
6. Follow the procedure listed in After working inside your system.
7. Install any device drivers required for the expansion-card as described in the documentation for the
card.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing an expansion card into the expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
iDRAC ports card (optional)
The iDRAC ports card consists of the SD vFlash card slot and an iDRAC port. The iDRAC ports card is used
for advanced management of the system.
An SD vFlash card is a Secure Digital (SD) card that plugs into the SD vFlash card slot in the system. It
provides persistent on-demand local storage and a custom deployment environment that allows
automation of server configuration, scripts, and imaging. It emulates USB device(s). For more information,
see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmmanuals.
Removing the iDRAC ports card
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full-
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. Remove the expansion-card riser.
6. Keep the #2 Phillips screwdriver ready.
Steps
1. Disconnect the management network cable from the iDRAC port.
2. Loosen the two screws securing the iDRAC ports card holder to the system board.
3. Pull the iDRAC ports card up and toward the front of the system to disengage it from the connector
and remove the card from the chassis.
82
Figure 29. Removing and installing the iDRAC ports card
1. iDRAC ports card holder 2. iDRAC port
3. SD vFlash media card reader 4. iDRAC ports card
5. screws (2) 6. iDRAC ports card connector on system
board
Next steps
1. Install the expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Install the cooling shroud.
4. If applicable, open the expansion-card latch on the cooling shroud to secure the full-length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
83
Installing the iDRAC ports card
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full-
length card.
4. If applicable, disconnect the power or data cables from expansion-card (s).
5. If applicable, remove the expansion-card riser
Steps
1. Align and insert the tabs on the iDRAC ports card on the slots on the chassis wall.
2. Insert the iDRAC ports card into the connector on the system board.
3. Secure the iDRAC ports card using screws.
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable, open the expansion-card latch on the cooling shroud to secure the full-length
expansion-card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
SD vFlash media card
A vFlash SD card is a Secure Digital (SD) card that plugs into the vFlash SD card slot in the system. It
provides persistent on-demand local storage and a custom deployment environment that allows
automation of server configuration, scripts, and imaging. It emulates USB device(s). For more information,
see the Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals.
Replacing an SD vFlash media card
1. Locate the SD vFlash media slot at the back of the chassis.
2. To remove the SD vFlash media card, push the card inward to release it, and pull the card from the
card slot.
84
Figure 30. Removing and installing the SD vFlash media card
1. SD vFlash media card 2. SD vFlash media-card slot
3. To install an SD vFlash media card, insert the contact-pin end of the SD vFlash media card into the
card slot on the module.
NOTE: The slot is keyed to ensure correct insertion of the card.
4. Press the card inward to lock it into the slot.
Internal dual SD module
The Internal Dual SD Module (IDSDM) card provides two SD card slots. This card offers the following
features:
• Dual card operation — maintains a mirrored configuration using SD cards in both slots and provides
redundancy.
NOTE: When the Redundancy option is set to Mirror Mode in the Integrated Devices screen of
System Setup, the information is replicated from one SD card to another.
• Single card operation — single card operation is supported, but without redundancy.
Removing an internal SD card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
85
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
Locate the SD card slot on the internal dual SD module and press the card to release it from the slot.
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card.
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Installing an internal SD card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: To use an SD card with your system, ensure that the Internal SD Card Port is enabled in the
System Setup.
Steps
1. Locate the SD card connector on the internal dual SD module. Align the SD card appropriately and
insert the contact-pin end of the card into the slot.
NOTE: The slot is keyed to ensure correct insertion of the card.
2. Press the card into the card slot to lock it into place.
86
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Removing the internal dual SD module
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the internal dual SD module on the system board.
2. If installed, remove the SD card(s).
3. Hold the plastic pull tab and pull the dual SD module out of the system board.
87
Figure 31. Removing and installing the Internal Dual SD Module (IDSDM)
1. Internal Dual SD module 2. LED status indicator (2)
3. SD card (2) 4. SD card slot 2
5. SD card slot 1 6. IDSDM connector
The following table describes the IDSDM indicator codes.
Convention IDSDM indicator code Condition
A Green Indicates that the card is online
B Flashing green Indicates rebuild or activity
C Flashing amber Indicates card mismatch or that the card has
failed
D Amber Indicates that the card is offline, has failed, or is
write protected
88
Convention IDSDM indicator code Condition
E Not lit Indicates that the card is missing or is booting
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Installing the internal dual SD module
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the IDSDM connector on the system board.
2. Align the connectors on the system board and the dual SD module.
3. Push the dual SD module until it is firmly seated on the system board.
Next steps
1. Install the SD media card(s).
2. If applicable, install the PCIe expansion-card riser.
3. If applicable, connect the required power or data cables to the expansion card(s).
4. Reinstall the cooling shroud.
5. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
6. Follow the procedure listed in After working inside your system.
Related Links
89
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing an internal SD card
Installing the (optional) expansion-card riser
Installing the cooling shroud
Integrated storage controller card
Your system supports an integrated storage controller card that provides the integrated storage
subsystem for your system’s internal hard drives. The controller supports SAS/SATA and SSD drives and
also enables you to set up the hard drives in RAID configurations as supported by the version of the
storage controller included with your system.
Removing the integrated storage controller card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
6. Keep the #2 Phillips screwdriver ready.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Loosen the screws that secure the integrated storage controller cable to the integrated storage-
controller card connector on the system board.
2. Lift the integrated storage controller cable out and move it away from the integrated storage
controller card.
3. Lift one end of the card at an angle to disengage the card from the integrated storage-controller
card holder on system board.
4. Lift the card out of the chassis.
90
Figure 32. Removing and installing the integrated storage controller card
1. integrated storage controller cable 2. integrated storage controller card
3. integrated storage-controller card
connector on the system board 4. integrated storage controller card
holder
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
91
Installing the integrated storage controller card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
6. Keep the #2 Phillips screwdriver ready.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Align the end of the integrated storage-controller card opposite the connector with the integrated
storage-controller card holder.
2. Lower the connector side of the integrated storage-controller card into the integrated storage-
controller card connector on the system board.
Ensure that the tabs on the system board align with the screw holes on the integrated storage-
controller card.
3. Align the screws on the integrated storage-controller card cable with the screw holes on the
connector.
4. Tighten the screws to secure the integrated storage-controller card cable with the integrated
storage-controller card connector on the system board.
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Processors
Use the following procedure when:
92
• Installing an additional processor
• Replacing a processor
NOTE: To ensure proper system cooling, you must install a processor blank in any empty processor
socket.
Removing a processor
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: To ensure proper system cooling, you must install a processor blank in any empty processor
socket.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
6. Keep the #2 Phillips screwdriver ready.
7. If you are upgrading your system, download the latest system BIOS version from dell.com/support
and follow the instructions included in the compressed download file to install the update on your
system.
NOTE: You can update the system BIOS using the Lifecycle Controller.
WARNING: The heat sink and processor are hot to the touch for some time after the system has
been powered down. Allow the heat sink and processor to cool before handling them.
CAUTION: Never remove the heat sink from a processor unless you intend to remove the
processor. The heat sink is necessary to maintain proper thermal conditions.
Steps
1. To remove the heat sink:
a. Loosen one of the screws that secure the heat sink to the system board.
Wait 30 seconds for the heat sink to loosen from the processor.
b. Remove the screw diagonally opposite the screw you first removed.
c. Repeat the procedure for the remaining two screws.
d. Lift the heat sink out of the system.
93
Figure 33. Removing and installing a processor heat sink
1. captive screw (4) 2. heat sink
3. processor socket 4. slot (4)
CAUTION: The processor is held in its socket under strong pressure. Be aware that the
release lever can spring up suddenly if not grasped firmly.
94
Figure 34. Processor shield
1. close first socket release lever 2. lock icon
3. processor 4. open first socket release lever
5. unlock icon
2. To remove the processor:
a. Release the open first socket-lever near the unlock icon by pushing the lever down and out
from under the tab.
b. Similarly, release the close first socket-release lever near the lock icon by pushing the lever
down and out from under the tab. Lift the lever 90 degrees upward.
c. Lower the open first socket-release lever to lift the processor shield.
95
Figure 35. Removing and installing a processor
1. close first socket-release lever 2. pin-1 indicator of processor
3. processor 4. slot (4)
5. processor shield 6. open first socket-release lever
7. socket 8. socket keys (4)
d. Hold the tab on the processor shield and lift the processor shield until the open first socket-
release lever lifts up.
CAUTION: The socket pins are fragile and can be permanently damaged. Be careful not to
bend the pins in the socket when removing the processor out of the socket.
e. Lift the processor out of the socket and leave the open first socket-release lever up.
NOTE: If you are permanently removing the processor, you must install a socket protective
cap in the vacant socket to protect the socket pins and keep the socket free of dust.
NOTE: After removing the processor, place it in an anti-static container for reuse, return, or
temporary storage. Do not touch the bottom of the processor. Touch only the side edges of
the processor.
Next steps
1. Replace the heat sink(s) and processor(s).
2. If applicable, install the PCIe expansion-card riser.
3. If applicable, connect the required power or data cables to the expansion card(s).
96
4. Reinstall the cooling shroud.
5. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
6. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing a processor
Installing the (optional) expansion-card riser
Installing the cooling shroud
Installing a processor
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
6. Keep the #2 Phillips screwdriver ready.
7. If you are upgrading your system, download the latest system BIOS version from dell.com/support
and follow the instructions included in the compressed download file to install the update on your
system.
NOTE: You can update the system BIOS using the Lifecycle Controller.
CAUTION: Never remove the heat sink from a processor unless you intend to remove the
processor. The heat sink is necessary to maintain proper thermal conditions.
NOTE: If you are installing a single processor, it must be installed in socket CPU1.
Steps
1. Remove the heat sink.
2. Unpack the new processor.
If the processor has previously been used in a system, remove any remaining thermal grease from
the processor using a lint-free cloth.
3. Locate the processor socket.
4. If applicable, remove the socket protective cap.
5. Release the open first socket-release lever near the unlock icon by pushing the lever down and
out from under the tab.
97
6. Similarly, release the close first socket-release lever near the lock icon by pushing the lever down
and out from under the tab. Lift the lever 90 degrees upward.
7. Hold the tab near the lock symbol on the processor shield and lift it up and out of the way.
8. To install the processor in the socket:
CAUTION: Positioning the processor incorrectly can permanently damage the system board
or the processor. Be careful not to bend the pins in the socket.
CAUTION: While removing or reinstalling the processor, wipe your hands of any
contaminants. Contaminants on the processor pins such as thermal grease or oil can damage
the processor.
a. Align the processor with the socket keys.
CAUTION: Do not use force to seat the processor. When the processor is positioned
correctly, it engages easily into the socket.
b. Align the pin-1 indicator of the processor with the triangle on the socket.
c. Place the processor on the socket such that the slots on the processor align with the socket keys.
CAUTION: Do not use force to seat the processor. When the processor is positioned
correctly, it engages easily into the socket.
d. Close the processor shield.
e. Lower the close first socket-release lever near the lock icon and push it under the tab to lock
it.
f. Similarly, lower the open first socket-release lever near the unlock icon and push it under the
tab to lock it.
9. To install the heat sink:
a. If applicable, remove the existing thermal grease from the heat sink using a clean lint-free cloth.
b. Apply thermal grease on the top of the processor. Use the thermal-grease syringe included with
your processor kit to apply the grease in a thin spiral on the top of the processor as shown in the
figure.
CAUTION: Applying too much thermal grease can result in excess grease coming in
contact with and contaminating the processor socket.
98
Figure 36. Applying thermal grease on the top of the processor
1. processor 2. thermal grease
3. thermal-grease syringe
NOTE: The thermal-grease is intended for one-time use only. Dispose of the syringe after
you use it.
c. Place the heat sink onto the processor.
d. Tighten the four screws to secure the heat sink to the system board.
NOTE: Tighten the screws diagonally opposite to each other. Do not over-tighten the heat
sink retention screws when installing the heat sink. To prevent over-tightening, tighten the
retention screw until resistance is felt, and stop once the screw is seated. The screw tension
should be no more than 6 in-lb (6.9 kg-cm).
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Follow the procedure listed in After working inside your system.
6. While booting, press <F2> to enter the System Setup and check that the processor information
matches the new system configuration.
7. Run the system diagnostics to verify that the new processor operates correctly.
Related Links
99
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Power supplies
Your system supports:
• Two 495 W, 750 W, or 1100 W AC power supply modules
• One cabled 450 W power supply module (non-redundant)
• Two 750 W DC power supply modules
– When two identical power supplies are installed, the power supply configuration is redundant (1 +
1). In redundant mode, power is supplied to the system equally from both power supplies to
maximize efficiency.
– When only one power supply is installed, the power supply configuration is non-redundant (1 + 0).
Power is supplied to the system only by the single power supply.
– When configured in a 2+0 configuration, 1+1 redundancy will not be supported.
NOTE: If two power supplies are used, they must be of the same type and must have the same
maximum output power.
Hot Spare feature
Your system supports the Hot Spare feature that significantly reduces the power overhead associated
with power supply redundancy.
When the Hot Spare feature is enabled, one of the redundant power supplies is switched to a sleep state.
The active power supply supports 100% of the load, thus operating at higher efficiency. The power supply
in the sleep state monitors output voltage of the active power supply. If the output voltage of the active
power supply drops, the power supply in the sleep state returns to an active output state.
If having both power supplies active is more efficient than having one power supply in a sleep state, the
active power supply can also activate a sleeping power supply.
The default power supply settings are as follows:
• If the load on the active power supply is more than 50%, then the redundant power supply is switched
to the active state.
• If the load on the active power supply falls below 20%, then the redundant power supply is switched
to the sleep state
You can configure the Hot Spare feature using the iDRAC settings. For more information on iDRAC
settings, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/support/home.
Removing the power supply unit blank
If you are installing a second power supply unit, remove the power supply unit blank in the bay by
pulling the blank outward.
100
CAUTION: To ensure proper system cooling, the power supply blank must be installed in the
second power supply bay in a non-redundant configuration. Remove the power supply blank
only if you are installing a second power supply.
Figure 37. Removing and installing the power supply blank
1. power supply blank 2. power supply bay
Installing the power supply unit blank
Install the power supply unit blank only in the second power supply unit bay.
To install the power supply unit blank, align the blank with the power supply unit bay and push it into
the chassis until it clicks into place.
Removing an AC power supply unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: The system requires one power supply for normal operation. On power-redundant
systems, remove and replace only one power supply at a time in a system that is powered on.
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with
power supply removal. For information about the cable management arm, see the system’s rack
documentation.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
101
Steps
1. Disconnect the power cable from the power source and from the power supply unit you intend to
remove and remove the cables from the strap.
2. Press the release latch and slide the power supply unit out of the chassis.
Figure 38. Removing and installing an AC power supply unit
1. release latch 2. power supply unit cable connector
3. power supply unit 4. connector
5. power supply unit handle
Next steps
1. Install the AC power supply unit.
2. Follow the procedure listed in After working inside your system.
Related Links
Installing an AC power supply unit
Installing an AC power supply unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Verify that both the power supply units are the same type and have the same maximum output
power.
102
NOTE: The maximum output power (shown in watts) is listed on the power supply label.
2. If applicable, remove the power supply unit blank.
3. Slide the new power supply unit into the chassis until the power supply unit is fully seated and the
release latch snaps into place.
NOTE: If you unlatched the cable management arm, re-latch it. For information about the cable
management arm, see the system’s rack documentation.
4. Connect the power cable to the power supply unit and plug the cable into a power outlet.
CAUTION: When connecting the power cable, secure the cable with the strap.
NOTE: When installing, hot-swapping, or hot-adding a new power supply unit, wait for 15
seconds for the system to recognize the power supply unit and determine its status. The power
supply redundancy may not occur until discovery is complete. Wait until the new power supply
unit is discovered and enabled before you remove the other power supply unit. The power-
supply unit status indicator turns green to signify that the power supply unit is functioning
properly.
Non-redundant AC power supply (cabled)
Your system supports a cabled non-redundant 450 W AC power supply.
NOTE: When selecting or upgrading your system configuration, verify the system power
consumption with the Dell Energy Smart Solution Advisor at dell.com/ESSA to ensure optimum
power utilization.
Removing a non-redundant AC power supply (cabled)
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
6. Keep the #2 Phillips screwdriver ready.
Steps
1. Disconnect the power cable from the power source.
2. Disconnect the power cable from the power supply and remove the power cables from the cable
strap.
3. Disconnect all the power cables from the power supply to the system board and hard-drive
backplane.
4. Remove the screw securing the power supply to the chassis and slide the power supply out of the
power supply unit cage.
103
Figure 39. Removing and installing a non-redundant AC power supply (cabled)
1. screw 2. power supply unit cage
3. non-redundant power supply 4. standoff on the chassis
5. P1 cable connector 6. P2 cable connector
7. P3 cable connector 8. backplane connector
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Connect the power cable to the back of the power supply unit and secure the power cables to the
cable strap.
6. Reconnect the power cable to the power source.
7. Follow the procedure listed in After working inside your system.
Related Links
104
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Installing a non-redundant AC power supply (cabled)
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
6. Keep the #2 Phillips screwdriver ready.
Steps
1. Unpack the new power supply.
2. Slide the new power supply into the power supply unit cage until the power supply is fully seated.
3. Tighten the screw to secure the power supply to the chassis.
4. Connect all the power cables to the system board and hard-drive backplane.
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Follow the procedure listed in After working inside your system.
Wiring instructions for a DC power supply unit
Your system supports up to two –(48–60) V DC power supplies (when available).
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must
perform all connections to DC power and to safety grounds. Do not attempt connecting to DC
power or installing grounds yourself. All electrical wiring must comply with applicable local or
national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
CAUTION: Wire the unit with copper only, unless otherwise specified, use only 10 American Wire
Gauge (AWG) wire rated minimum 90 ºC for source and return. Protect the –(48–60) V DC (1
wire) with a branch circuit over-current protection rated 50 A for DC with a high interrupt
current rating.
105
CAUTION: Connect the equipment to a –(48–60) V DC supply source that is electrically isolated
from the AC source (reliably grounded –(48–60) V DC SELV source). Ensure that the –(48–60) V
DC source is efficiently secured to earth (ground).
NOTE: A readily accessible disconnect device that is suitably approved and rated shall be
incorporated in the field wiring.
Input requirements
• Supply voltage: –(48–60) V DC
• Current consumption: 32 A (maximum)
Kit contents
• Dell part number 6RYJ9 terminal block or equivalent (1)
• #6-32 nut equipped with lock washer (1)
Required tools
Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper
wire
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding)
Required wires
• One UL 10 AWG, 2 m maximum (stranded) black wire [–(48–60) V DC]
• One UL 10 AWG, 2 m maximum (stranded) red wire (V DC return)
• One UL 10 AWG, 2 m maximum green/yellow, green with a yellow stripe, stranded wire (safety
ground)
Assembling and connecting the safety ground wire
Prerequisites
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must
perform all connections to DC power and to safety grounds. Do not attempt connecting to DC
power or installing grounds yourself. All electrical wiring must comply with applicable local or
national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
Steps
1. Strip the insulation from the end of the green/yellow wire, exposing approximately 4.5 mm (0.175
inch) of copper wire.
2. Using a hand-crimping tool (Tyco Electronics, 58433-3 or equivalent), crimp the ring-tongue
terminal (Jeeson Terminals Inc., R5-4SA or equivalent) to the green/yellow wire (safety ground wire).
3. Connect the safety ground wire to the grounding post on the back of the system using a #6-32 nut
equipped with a locking washer.
106
Figure 40. Assembling and connecting the safety ground wire
1. #6-32 nut 2. spring washer
3. locking washer 4. safety ground wire
5. grounding post
Assembling the DC input power wires
Prerequisites
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must
perform all connections to DC power and to safety grounds. Do not attempt connecting to DC
power or installing grounds yourself. All electrical wiring must comply with applicable local or
national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
Steps
1. Strip the insulation from the ends of the DC power wires, exposing approximately 13 mm (0.5 inch)
of copper wire.
WARNING: Reversing polarity when connecting DC power wires can permanently damage
the power supply or the system.
2. Insert the copper ends into the mating connectors and tighten the captive screws at the top of the
mating connector using a #2 Phillips screwdriver.
WARNING: To protect the power supply from electrostatic discharge, the captive screws
must be covered with the rubber cap before inserting the mating connector into the power
supply.
3. Rotate the rubber cap clockwise to fix it over the captive screws.
4. Insert the mating connector into the power supply.
107
Figure 41. Assembling the DC input power wires
1. wire RTN 2. DC power connector
3. captive screws (2) 4. rubber cap
5. DC power socket 6. wire –48 V
Removing a DC power supply unit
Prerequisites
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must
perform all connections to DC power and to safety grounds. Do not attempt connecting to DC
power or installing grounds yourself. All electrical wiring must comply with applicable local or
national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
CAUTION: The system requires one power supply for normal operation. On power-redundant
systems, remove and replace only one power supply at a time in a system that is powered on.
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with
power supply removal. For information about the cable management arm, see the system’s rack
documentation.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
Steps
1. Disconnect the power wires from the power source and the connector from the power supply you
intend to remove.
2. Disconnect the safety ground wire.
3. Press the release latch and slide the power supply out of the chassis.
108
Figure 42. Removing and installing a DC power supply
1. release latch 2. power supply status indicator
3. power supply 4. connector
5. power supply handle
Next steps
• Follow the procedure listed in After working inside your system.
Installing a DC power supply unit
Prerequisites
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must
perform all connections to DC power and to safety grounds. Do not attempt connecting to DC
power or installing grounds yourself. All electrical wiring must comply with applicable local or
national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Verify that both the power supplies are of the same type and have the same maximum output
power.
NOTE: The maximum output power (shown in watts) is listed on the power supply label.
Steps
1. If installed, remove the power supply blank.
2. Slide the new power supply unit into the chassis until the power supply unit is fully seated and the
release latch snaps into place.
109
NOTE: If you unlatched the cable management arm, relatch it. For information about the cable
management arm, see the system’s rack documentation.
3. Connect the safety ground wire.
4. Install the DC power connector in the power supply unit.
CAUTION: When connecting the power wires, secure the wires with the strap to the power
supply handle.
5. Connect the wires to a DC power source.
NOTE: When installing, hot-swapping, or hot-adding a new power supply, wait for 15 seconds
for the system to recognize the power supply and determine its status. The power-supply
status indicator turns green to signify that the power supply is functioning properly.
Next steps
• Follow the procedure listed in After working inside your system.
Power interposer board
The power interposer board (PIB) is only supported in systems with redundant power supplies.
Removing the power interposer board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
CAUTION: To prevent damage to the power interposer board, you must remove the power supply
module(s) or power supply blank from the system before removing the power interposer board or
power distribution board.
Steps
1. Remove the power supply module(s) from the back of the chassis.
2. Disconnect the power cables from the hard-drive backplane and the system board.
3. Press the release latch on the PIB to release it from the hooks on the power supply unit cage.
4. Lift the PIB up and out of the chassis.
110
Figure 43. Removing and installing the power interposer board
1. GPU power connector 2. power interposer board
3. release latch 4. hooks (4)
5. locking slots (4)
Next steps
1. Install the replacement power interposer board and connect all the required cables to the system
board and the hard drive backplane.
2. If applicable, install the PCIe expansion-card riser.
3. If applicable, connect the required power or data cables to the expansion card(s).
4. Reinstall the cooling shroud.
5. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
6. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the power interposer board
Installing the (optional) expansion-card riser
Installing the cooling shroud
111
Installing the power interposer board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
Steps
1. Align the locking slots on the power interposer board with the hooks on the power supply cage and
slide it into place.
2. Route the power cables as applicable, and connect the power cables to the system board and hard
drive backplane.
3. Install the power supply module(s) in their original locations.
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
5. Follow the procedure listed in After working inside your system.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
System battery
Replacing the system battery
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
112
NOTE: If applicable, close the expansion-card latch on the cooling shroud to release the full
length card.
4. If applicable, disconnect the power or data cables from expansion card (s).
5. If applicable, remove the expansion-card riser
WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the
battery only with the same or equivalent type recommended by the manufacturer. See your
safety information for additional information.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the battery socket, see System board connectors.
CAUTION: To avoid damage to the battery connector, you must firmly support the connector
while installing or removing a battery.
2. To eject the battery, press firmly on the edge of the positive side of the battery in the direction of the
arrow as shown in the illustration below.
1. positive side of battery 2. socket
3. To install a new system battery, hold the battery with the positive side facing up and slide it under the
securing tabs.
4. Press the battery into the connector until it snaps into place.
Next steps
1. If applicable, install the PCIe expansion-card riser.
2. If applicable, connect the required power or data cables to the expansion card(s).
3. Reinstall the cooling shroud.
4. If applicable, open the expansion-card latch on the cooling shroud to secure the full length
expansion card.
113
5. Follow the procedure listed in After working inside your system.
6. While booting, press <F2> to enter the System Setup and ensure that the battery is operating
properly.
7. Enter the correct time and date in the System Setup Time and Date fields.
8. Exit the System Setup.
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Installing the (optional) expansion-card riser
Installing the cooling shroud
Hard-Drive Backplane
Removing the hard-drive backplane
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: To prevent damage to the hard drives and hard-drive backplane, you must remove the
hard drives from the system before removing the hard-drive backplane.
CAUTION: You must note the number of each hard drive and temporarily label them before
removal so that you can replace them in the same locations.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
Steps
1. Disconnect the SAS/SATA/SSD hard drives, data cable(s) and power cable from the hard-drive
backplane.
2. Press the hard-drive backplane release tabs to disengage the backplane from the chassis.
3. Pull the hard-drive backplane away from the system until the securing hooks on the system chassis
are free from the slots on the hard-drive backplane.
Figure 44. Removing and installing the hard-drive backplane
1. release tab (2) 2. SAS A connector
3. backplane signal connector 4. backplane power connector
114
5. SAS B connector 6. hard-drive connectors (8)
Figure 45. Cabling diagram of the hard-drive backplane using the onboard controller
1. system board 2. SATA A cable connector on system
board
3. SATA B cable connector on system board 4. signal cable connector on system board
5. hard-drive backplane 6. SAS B cable connector on backplane
7. signal cable connector on backplane 8. SAS A cable connector on backplane
115
Figure 46. Cabling diagram of the hard-drive backplane using the integrated storage controller
1. system board 2. integrated storage controller connector
3. integrated storage controller 4. signal cable connector on system board
5. hard-drive backplane 6. SAS B cable connector on backplane
7. signal cable connector on backplane 8. SAS A cable connector on backplane
Next steps
1. Reconnect the data cable(s) and power cable to the hard-drive backplane
2. Install all SAS/SATA/SSD hard drives into their original locations.
3. Follow the procedure listed in After working inside your system.
Related Links
Removing a hot-swap hard drive
Installing a hot-swap hard drive
Installing the hard-drive backplane
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Disconnect the data, signal and power cables to the backplane.
4. Remove all SAS/SATA/SSD hard drives.
116
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Use the hooks on the chassis as guides to align the hard-drive backplane.
2. Lower the hard-drive backplane until the release tabs snap into place.
3. Connect the SAS/SATA/SSD data, signal, and power cable(s) to the backplane.
Next steps
1. Install all SAS/SATA/SSD hard drives in their original locations.
2. Reconnect the data, signal and power cables to the backplane.
3. Follow the procedure listed in After working inside your system.
Related Links
Removing a hot-swap hard drive
Installing a hot-swap hard drive
Control panel and I/O module
Removing the control-panel board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure that the
locking tab on the connector is released before removal and insertion. The locking tab must be
engaged after insertion.
NOTE: To prevent damage to the LCD display module cable, do not bend the control panel flex
cable after it is inserted into the connector.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #2 Phillips screwdriver ready.
Steps
1. Disconnect the USB cable, control panel cable, and the LCD display module cable from the control-
panel board.
2. Using a #2 Phillips screwdriver, remove the two screws that secure the control-panel board to the
chassis.
3. Slide the control-panel board toward the back and lift it out of the system.
117
Figure 47. Removing and installing the control-panel board
1. control-panel board 2. screws (2)
3. control-panel data cable 4. LCD display module cable
5. USB cable
Next steps
1. Reconnect the USB cable, control panel cable, and the LCD display module cable to the control-
panel board.
2. Follow the procedure listed in After working inside your system.
Installing the control-panel board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #2 Phillips screwdriver ready.
118
Steps
1. Fit the control-panel board in the chassis, while aligning the screw holes on the control-panel board
with the standoffs on the chassis.
2. Secure the control-panel board to the chassis with the two screws.
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure
that the locking tab on the connector is released before removal and insertion. The locking
tab must be engaged after insertion.
3. Connect the USB cable, control panel cable, and the display module cable to the control-panel
board.
4. Route the power/data cables through the cable retention bracket.
Next steps
1. Follow the procedure listed in After working inside your system.
Removing the control panel
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #2 Phillips screwdriver ready.
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure
that the locking tab on the connector is released before removal and insertion. The locking
tab must be engaged after insertion.
Steps
1. Disconnect the display module cable from the control-panel board.
NOTE: The control panel has seven tabs that secure it to the chassis.
CAUTION: Applying excessive force may damage the control panel.
2. Slide the display module cable out of the plastic cable guide.
3. Remove the cable guide after unscrewing the two retaining screws.
4. Hold the top edge of the control panel at the corners and pull upward until the control panel tabs
release.
5. Pull the control panel away from the chassis.
119
Figure 48. Removing and installing the control panel
a. locks on the control panel (7)
b. control panel
c. cable guide retaining screw (2)
d. cable guide
e. display module cable
Next steps
1. Reconnect the display module cable to the control-panel board
2. Follow the procedure listed in After working inside your system.
Installing the control panel
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #2 Phillips screwdriver ready.
120
Steps
1. Slide the left side of the control panel into the chassis so that the left tab on the control panel aligns
with the slot on the chassis wall and the top left tab aligns with the slot on the top of the chassis.
2. Pull the display module cable through the opening slot in the front and into the chassis.
3. Slide the display module cable into the plastic cable guide.
4. Fix the cable guide to the chassis by screwing the two retaining screws.
5. Push the right side of the control panel until the top right tab aligns with the top of the chassis and
the control panel snaps into place.
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure
that the locking tab on the connector is released before removal and insertion. The locking
tab must be engaged after insertion.
6. Connect the display module cable to the control panel board.
Next steps
• Follow the procedure listed in After working inside your system.
System board
Removing the system board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: If you are using the Trusted Program Module (TPM) with an encryption key, you may
be prompted to create a recovery key during program or System Setup. Be sure to create and
safely store this recovery key. If you replace this system board, you must supply the recovery key
when you restart your system or program before you can access the encrypted data on your hard
drives.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove / disconnect the following components:
a. cooling shroud
b. cooling fans
c. power supply(s)
d. the expansion-card riser
e. integrated storage controller card
f. internal dual SD module
g. internal USB key (if installed)
h. heat sink(s)/heat-sink blank(s)
i. processors(s)/processor blank(s)
CAUTION: To prevent damage to the processor pins when replacing a faulty system
board, ensure that you cover the processor socket with the processor protective cap.
121
j. memory modules and memory module blanks
4. Keep the #2 Phillips screwdriver ready.
Steps
1. Disconnect the SAS cable from the system board.
2. Disconnect all other data and power cables from the system board.
CAUTION: Take care not to damage the system identification button while removing the
system board from the chassis.
CAUTION: Do not lift the system board assembly by holding a memory module, processor, or
other components.
3. Remove the screws securing the system board to the chassis.
Figure 49. Screw location on the system board
a. system board screw (9)
b. system board holder
4. Hold the system-board holder, lift the system board and slide it toward the front of the chassis.
122
Figure 50. Removing and installing the system board
1. system board 2. system-board holder
Related Links
Removing the cooling shroud
Removing the (optional) expansion-card riser
Removing an AC power supply unit
Removing the integrated storage controller card
Removing the internal dual SD module
Replacing the internal USB key
Removing a processor
Removing a memory module
Installing the system board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
123
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #2 Phillips screwdriver ready.
Steps
1. Unpack the new system board assembly.
CAUTION: Do not lift the system board assembly by holding a memory module, processor, or
other components.
CAUTION: Take care not to damage the system identification button while placing the
system board into the chassis.
2. Hold the touch points and lower the system board into the chassis.
3. Push the system board toward the back of the chassis until the board clicks into place.
Next steps
1. Install the Trusted Platform Module (TPM). For more information on TPM, see Trusted Platform
Module.
2. Install / connect the following components:
a. integrated storage controller card
b. internal USB key (if installed)
c. internal dual SD module
d. the expansion-card riser
e. heat sink(s)/heat-sink blank(s) and processors(s)/processor blank(s)
f. memory modules and memory module blanks
g. cooling-fans
h. cooling shroud
i. power supply unit(s)
3. Reconnect all cables to the system board.
NOTE: Ensure that the cables inside the system are routed along the chassis wall .
4. Follow the procedure listed in After working inside your system.
5. Ensure that you:
a. Use the Easy Restore feature to restore the service tag.
b. If the service tag is not backed up in the backup flash device, enter the system service tag
manually.
c. Import your new or existing iDRAC Enterprise license. For more information, see Integrated Dell
Remote Access Controller 8 (iDRAC8) User's Guide, at dell.com/esmmanuals.
d. Update the BIOS and iDRAC versions.
e. Re-enable the Trusted Platform Module (TPM).
Related Links
Installing the Trusted Platform Module
Installing the integrated storage controller card
Replacing the internal USB key
Installing the internal dual SD module
Installing the (optional) expansion-card riser
Installing a processor
124
Installing memory modules
Installing the cooling shroud
Installing an AC power supply unit
Restoring the Service Tag using Easy Restore
Entering the system Service Tag using System Setup
Re-enabling the TPM for BitLocker users
Re-enabling the TPM for TXT users
Restoring the Service Tag using Easy Restore
Use the Easy Restore feature if you do not know the Service Tag of your system. The Easy Restore feature
allows you to restore your system’s Service Tag, license, UEFI configuration, and the system configuration
data after replacing the system board. All data is backed up in a backup flash device automatically. If BIOS
detects a new system board and the Service Tag in the backup flash device, BIOS prompts the user to
restore the backup information.
1. Turn on the system.
If BIOS detects a new system board, and if the Service Tag is present in the backup flash device, BIOS
displays the Service Tag, the status of the license, and the UEFI Diagnostics version.
2. Do one of the following:
• Press Y to restore the Service Tag, license, and diagnostics information.
• Press N to navigate to the Lifecycle Controller based restore options.
• Press <F10> to restore data from a previously created Hardware Server Profile.
After the restore process is complete, BIOS prompts to restore the system configuration data.
3. Do one of the following:
• Press Y to restore the system configuration data.
• Press N to use the default configuration settings.
After the restore process is complete, the system restarts.
Entering the system Service Tag using System Setup
If you know the system Service Tag, use the System Setup menu to enter the Service Tag.
1. Turn on the system.
2. Press <F2> to enter the System Setup.
3. Click Service Tag Settings.
4. Enter the Service Tag.
NOTE: You can enter the only when the Service Tag field is empty. Ensure that you enter the
correct Service Tag. Once the Service Tag is entered, it cannot be updated or changed.
5. Click Ok.
6. Import your new or existing iDRAC Enterprise license.
For more information, see Integrated Dell Remote Access Controller User's Guide, at dell.com/
esmmanuals.
125
Trusted Platform Module
The Trusted Platform Module (TPM) is used to generate/store keys, protect/authenticate passwords, and
create/store digital certificates. TPM can also be used to enable the BitLocker hard drive encryption
feature in Windows Server.
CAUTION: Do not attempt to remove the Trusted Platform Module (TPM) from the system board.
Once the TPM is installed, it is cryptographically bound to that specific system board. Any
attempt to remove an installed TPM breaks the cryptographic binding, and it cannot be re-
installed or installed on another system board.
Installing the Trusted Platform Module
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Do not remove an installed Trusted Platform Module (TPM). Any attempt to remove an
installed TPM from the system board may damage the TPM.
Steps
1. Align the edge connectors on the TPM with the slot on the TPM connector.
2. Insert the TPM into the TPM connector such that the plastic bolt aligns with the slot on the system
board.
3. Press the plastic bolt until the bolt snaps into place.
Figure 51. Installing the TPM
1. TPM 2. TPM connector
126
3. slot on the TPM connector 4. plastic bolt
5. slot on the system board
Next steps
Follow the procedure listed in After working inside your system.
Re-enabling the TPM for BitLocker users
Initialize the TPM.
For more information on initializing the TPM, see http://technet.microsoft.com/en-us/library/
cc753140.aspx.
The TPM Status changes to Enabled, Activated.
Re-enabling the TPM for TXT users
1. While booting your system, press <F2> to enter System Setup.
2. In the System Setup Main Menu, click System BIOS → System Security Settings.
3. In the TPM Security option, select On with Pre-boot Measurements.
4. In the TPM Command option, select Activate.
5. Save the settings.
6. Restart your system.
7. Enter System Setup again.
8. In the System Setup Main Menu, click System BIOS → System Security Settings.
9. In the Intel TXT option, select On.
127
5
Troubleshooting your system
Safety first—for you and your system
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Troubleshooting system startup failure
If you boot the system to the BIOS boot mode after installing an operating system from the UEFI Boot
Manager, the system hangs. The reverse is also true. You must boot to the same boot mode in which you
installed the operating system.
For all other startup issues, note the system messages that appear on the screen.
Troubleshooting external connections
Ensure that all external cables are securely attached to the external connectors on your system before
troubleshooting any external devices.
Troubleshooting the video subsystem
1. Check the system and power connections to the monitor.
2. Check the video interface cabling from the system to the monitor.
3. Run the appropriate diagnostic test.
If the tests run successfully, the problem is not related to video hardware.
If the tests fail, see Getting Help.
Troubleshooting a USB device
About this task
Use the following steps to troubleshoot a USB keyboard/mouse. For other USB devices, go to step 7.
Steps
1. Disconnect the keyboard and mouse cables from the system and reconnect them.
2. If the problem persists, connect the keyboard/mouse to the USB port(s) on the opposite side of the
system.
128
3. If the problem is resolved, restart the system, enter the System Setup, and check if the non-
functioning USB ports are enabled.
Check if USB 3.0 is enabled in System Setup. If enabled, disable it and see if the issue is resolved
(older operating systems may not support USB 3.0).
4. In the IDRAC Settings Utility, ensure the USB Management Port Mode is configured as Automatic or
Standard OS Use.
5. Replace the keyboard/mouse with a working keyboard/mouse.
If the problem is not resolved, proceed to the next step to begin troubleshooting other USB devices
attached to the system.
6. Power down all attached USB devices and disconnect them from the system.
7. Restart the system and, if your keyboard is functioning, enter the System Setup.
8. Verify that all USB ports are enabled on the Integrated Devices screen, in the System Setup options.
9. Check if USB 3.0 is enabled in System Setup. If it is enabled, disable it and restart your system.
If your keyboard is not functioning, you can also use remote access.
10. If the system is not accessible, reset the NVRAM_CLR jumper inside your system and restore the
BIOS to the default settings.
11. In the IDRAC Settings Utility, ensure the USB Management Port Mode is configured as Automatic or
Standard OS Use.
12. Reconnect and power on each USB device one at a time.
13. If a USB device causes the same problem, power down the device, replace the USB cable with a
known good cable, and power up the device.
Next steps
If all troubleshooting fails, see Getting Help.
Troubleshooting a serial I/O device
Steps
1. Turn off the system and any peripheral devices connected to the serial port.
2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.
If the problem is resolved, replace the interface cable with a known good cable.
3. Turn off the system and the serial device, and swap the device with a comparable device.
4. Turn on the system and the serial device.
Next steps
If the problem persists, see Getting Help.
Troubleshooting a NIC
Steps
1. Run the appropriate diagnostic test. See Using System Diagnostics for available diagnostic tests.
2. Reboot the system and check for any system messages pertaining to the NIC controller.
3. Check the appropriate indicator on the NIC connector:
• If the link indicator does not light, check all cable connections.
• If the activity indicator does not light, the network driver files might be damaged or missing.
129
Remove and reinstall the drivers if applicable. See the NIC's documentation.
• If applicable, change the autonegotiation setting.
• Use another connector on the switch or hub.
4. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's
documentation.
5. Enter the System Setup and confirm that the NIC ports are enabled on the Integrated Devices
screen.
6. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission
speed and duplex. See the documentation for each network device.
7. Ensure that all network cables are of the proper type and do not exceed the maximum length.
Next steps
If all troubleshooting fails, see Getting Help.
Troubleshooting a wet system
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2. Remove the system cover.
3. Remove the following components from the system:
• hard drives
• hard-drive backplane
• USB memory key
• hard-drive tray
• cooling shroud
• expansion-card risers (if present)
• expansion cards
• power supply unit(s)
• cooling-fan assembly (if present)
• cooling fans
• processor(s) and heat sink(s)
• memory modules
4. Let the system dry thoroughly for at least 24 hours.
5. Reinstall the components you removed in step 3.
6. Install the system cover.
7. Turn on the system and attached peripherals.
If the system does not start properly, see Getting Help.
8. If the system starts properly, shut down the system, and reinstall all the expansion cards that you
removed.
130
9. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Next steps
If the tests fail, see Getting Help.
Troubleshooting a damaged system
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2. Remove the system cover.
3. Ensure that the following components are properly installed:
• Cooling shroud
• Expansion-card risers (if present)
• Expansion cards
• Power supply(s)
• Cooling-fan assembly (if present)
• Cooling fans
• Processor(s) and heat sink(s)
• Memory modules
• Hard-drive carriers
• Hard-drive backplane
4. Ensure that all cables are properly connected.
5. Install the system cover.
6. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Next steps
If the tests fail, see Getting Help.
Troubleshooting the system battery
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may
lose its system configuration information. This situation is caused by a defective battery.
131
Steps
1. Re-enter the time and date in the System Setup.
2. Turn off the system and disconnect it from the electrical outlet for at least one hour.
3. Reconnect the system to the electrical outlet and turn on the system.
4. Enter the System Setup.
If the date and time are not correct in the System Setup, check the SEL for system battery messages.
Next steps
If the problem persists, see Getting Help.
NOTE: Some software may cause the system time to speed up or slow down. If the system seems
to operate normally except for the time kept in the System Setup, the problem may be caused by
software rather than by a defective battery.
Troubleshooting power supply units
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Power source problems
1. Press the power button to ensure that your system is turned on. If the power indicator does not light
up when the power button is pressed, press the power-on button firmly.
2. Plug in another working device to ensure that the system board is not faulty.
3. Ensure that no loose connections exist.
For example, loose power cables.
4. Ensure that the power source meets applicable standards.
5. Ensure that there are no short circuits.
6. Have a qualified electrician check the line voltage to ensure that it meets the required specifications.
Power supply unit problems
1. Ensure that no loose connections exist.
For example, loose power cables.
2. Ensure that the power supply handle/LED indicates that the power supply is working properly.
3. If you have recently upgraded your system, ensure that the power supply unit has enough power to
support the new system.
4. If you have a redundant power supply configuration, ensure that both the power supply units are of
the same type and wattage.
If the LED You may have to upgrade to a higher wattage power supply unit.
5. Ensure that you use only power supply units with the Extended Power Performance (EPP) label on
the back.
6. Reseat the power supply unit.
132
NOTE: After installing a power supply unit, allow several seconds for the system to recognize
the power supply unit and determine if it is working properly.
If the problem persists, see Getting Help.
Troubleshooting cooling problems
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Ensure that the following conditions exist:
• System cover, cooling shroud, EMI filler panel, memory-module blank, or back-filler bracket is not
removed.
• Ambient temperature is not too high.
• External airflow is not obstructed.
• A cooling fan is not removed or has not failed.
• The expansion card installation guidelines have been followed.
Additional cooling can be added by one of the following methods:
From the iDRAC Web GUI
1. Click Hardware → Fans → Setup.
2. From the Fan Speed Offset drop-down list, select the cooling level needed or set the minimum fan
speed to a custom value.
From F2 System Setup
1. Select iDRAC Settings → Thermal, and set a higher fan speed from the fan speed offset or minimum
fan speed.
From RACADM commands
1. Run the command racadm help system.thermalsettings
For more information, see the Integrated Dell Remote Access User’s Guide at dell.com/esmmanuals.
Troubleshooting cooling fans
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: In the event of a problem with a particular fan, the fan number is referenced by the system’s
management software, allowing you to easily identify and replace the proper fan by noting the fan
numbers on the cooling fan assembly.
133
Steps
1. Remove the system cover.
2. Reseat the fan or the fan's power cable.
3. Install the system cover.
4. Restart your system.,
Next steps
If the problem persists, see Getting Help.
Troubleshooting system memory
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. If the system is operational, run the appropriate diagnostic test. See Using system diagnostics for
available diagnostic tests.
If diagnostics indicate a fault, follow the corrective actions provided by the diagnostic program.
2. If the system is not operational, turn off the system and attached peripherals, and unplug the system
from the power source. Wait at least 10 seconds and then reconnect the system to the power
source.
3. Turn on the system and attached peripherals and note the messages on the screen.
If an error message is displayed indicating a fault with a specific memory module, go to step 12.
4. Enter the System Setup and check the system memory setting. Make any changes to the memory
settings, if needed.
If the memory settings match the installed memory but the problem still persists, go to step 12.
5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6. Remove the system cover.
7. Check the memory channels and ensure that they are populated correctly.
NOTE: See the system event log or system messages for the location of the failed memory
module. Reinstall the memory device.
8. Reseat the memory modules in their sockets.
9. Install the system.
10. Enter the System Setup and check the system memory setting.
If the problem is not resolved, proceed with the next step.
11. Remove the system cover.
12. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace
the module with a known good memory module.
13. To troubleshoot an unspecified faulty memory module, replace the memory module in the first
DIMM socket with a module of the same type and capacity.
If an error message is displayed on the screen, this may indicate a problem with the installed DIMM
type(s), incorrect DIMM installation, or defective DIMM(s). Follow the on-screen instructions to
resolve the problem.
134
14. Install the system cover.
15. As the system boots, observe any error message that is displayed and the diagnostic indicators on the
front of the system.
16. If the memory problem persists, repeat step 12 through step 15 for each memory module installed.
Next steps
If the problem persists after all memory modules have been checked, see Getting Help.
Troubleshooting an internal USB key
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Enter the System Setup and ensure that the USB key port is enabled on the Integrated Devices
screen.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Locate the USB key and reseat it.
5. Install the system cover.
6. Turn on the system and attached peripherals and check if the USB key is functioning.
7. If the problem is not resolved, repeat step 2 and step 3.
8. Insert a different USB key that you know works properly.
9. Install the system cover.
Next steps
If the problem is not resolved, see Getting Help.
Troubleshooting an SD card
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: Certain SD cards have a physical write-protect switch on the card. If the write-protect switch
is turned on, the SD card is not writeable.
Steps
1. Enter the System Setup and ensure that the Internal SD Card Port is enabled.
2. Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
3. Remove the system cover.
135
NOTE: When an SD card failure occurs, the internal dual SD module controller notifies the
system. On the next restart, the system displays a message indicating the failure. If redundancy
is enabled at the time of SD card failure, a critical alert will be logged and chassis health will
degrade.
4. Replace the failed SD card with a new SD card.
5. Install the system cover.
6. Reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
7. Enter the System Setup and ensure that the Internal SD Card Port and Internal SD Card Redundancy
mode is set to the required mode.
Verify that correct SD slot is set as Primary SD Card.
8. Check if the SD card is functioning properly.
9. If the Internal SD Card Redundancy option is set to Enabled at the time of the SD card failure, the
system will prompt you to perform a rebuild.
NOTE: The rebuild will always be sourced from the primary SD card to the secondary SD card.
Perform the rebuild of the SD card as necessary.
Troubleshooting an optical drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Try using a different CD or DVD.
2. Enter the System Setup and ensure that the integrated SATA controller and the drive's SATA port are
enabled.
3. Run the appropriate diagnostic test.
4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
5. If installed, remove the front bezel.
6. Remove the system cover.
7. Ensure that the interface cable is securely connected to the optical drive and to the controller.
8. Ensure that a power cable is properly connected to the drive.
9. Install the system cover.
Next steps
If the problem is not resolved, see Getting Help.
136
Troubleshooting a hard drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: This troubleshooting procedure can erase data stored on the hard drive. Before you
proceed, back up all files on the hard drive.
Steps
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Depending on the results of the diagnostics test, proceed as needed through the following steps.
2. If your system has a RAID controller and your hard drives are configured in a RAID array, perform the
following steps:
a. Reboot the system and press <F10> during system startup to run the Lifecycle Controller, and
then run the Hardware Configuration wizard to check the RAID configuration.
See the Lifecycle Controller documentation or online help for information on RAID configuration.
b. Ensure that the hard drive(s) are configured correctly for the RAID array.
c. Take the hard drive offline and reseat the drive.
d. Exit the configuration utility and allow the system to boot to the operating system.
3. Ensure that the required device drivers for your controller card are installed and are configured
correctly. See the operating system documentation for more information.
4. Reboot the system and enter the System Setup.
5. Verify that the controller is enabled and the drives are displayed in the System Setup.
Next steps
If the problem persists, try troubleshooting the expansion cards or see Getting Help.
Troubleshooting a storage controller
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: When troubleshooting a SAS or PERC controller, see the documentation for your operating
system and the controller.
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Verify that the installed expansion cards are compliant with the expansion card installation
guidelines.
5. Ensure that each expansion card is firmly seated in its connector.
6. Install the system cover.
137
7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
8. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
9. Remove the system cover.
10. Remove all expansion cards installed in the system.
11. Install the system cover.
12. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13. Run the appropriate diagnostic test. For more information, see Using System Diagnostics. If the tests
fail, see Getting Help.
14. For each expansion card you removed in step 10, perform the following steps:
a. Turn off the system and attached peripherals, and disconnect the system from the electrical
outlet.
b. Remove the system cover.
c. Reinstall one of the expansion cards.
d. Install the system cover.
e. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
If the tests fail, see Getting Help.
Troubleshooting expansion cards
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: When troubleshooting an expansion card, see the documentation for your operating system
and the expansion card.
Steps
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics .
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Open the system.
4. Ensure that each expansion card is firmly seated in its connector.
5. Close the system.
6. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
7. Open the system.
8. Remove all expansion cards installed in the system.
9. Close the system.
10. Run the appropriate diagnostic test. For more information, see Using System Diagnostics .
If the tests fail, see Getting Help.
11. For each expansion card you removed in step 8, perform the following steps:
a. Turn off the system and attached peripherals, and disconnect the system from the electrical
outlet.
b. Open the system.
138
c. Reinstall one of the expansion cards.
d. Close the system.
e. Run the appropriate diagnostic test. For more information, see Using System Diagnostics .
Next steps
If the problem persists, see Getting Help.
Troubleshooting processors
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Run the appropriate diagnostics test. See Using System Diagnostics for available diagnostic tests.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Open the system.
4. Ensure that the processor and heat sink are properly installed.
5. Close the system.
6. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Next steps
If the problem persists, see Getting Help.
System messages
Warning messages
A warning message alerts you to a possible problem and prompts you to respond before the system
continues a task. For example, before you format a hard drive, a message warns you that you may lose all
data on the hard drive. Warning messages usually interrupt the task and require you to respond by typing
y (yes) or n (no).
NOTE: Warning messages are generated by either the application or the operating system. For more
information, see the documentation that accompanied the operating system or application.
Diagnostic messages
The system diagnostic utilities may issue messages if you run diagnostic tests on your system. See Using
system diagnostics. for more information about system diagnostics.
139
Alert messages
Systems management software generates alert messages for your system. Alert messages include
information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For
more information, see the systems management software documentation.
140
6
Using system diagnostics
If you experience a problem with your system, run the system diagnostics before contacting Dell for
technical assistance. The purpose of running system diagnostics is to test your system hardware without
requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service
and support personnel can use the diagnostics results to help you solve the problem.
Dell Embedded System Diagnostics
NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System
Assessment (ePSA) diagnostics.
The embedded system diagnostics provides a set of options for particular device groups or devices
allowing you to:
• Run tests automatically or in an interactive mode
• Repeat tests
• Display or save test results
• Run thorough tests to introduce additional test options to provide extra information about the failed
device(s)
• View status messages that inform you if tests are completed successfully
• View error messages that inform you of problems encountered during testing
When to use the Embedded System Diagnostics
If a major component or device in the system does not operate properly, running the embedded system
diagnostics may indicate component failure.
Running the Embedded System Diagnostics
The embedded system diagnostics program is run from the Dell Lifecycle Controller.
Prerequisites
CAUTION: Use the embedded system diagnostics to test only your system. Using this program
with other systems may cause invalid results or error messages.
Steps
1. As the system boots, press <F11>.
2. Use the up and down arrow keys to select System Utilities → Launch Dell Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the
system. The diagnostics starts executing the tests on all the detected devices.
141
System diagnostic controls
Menu Description
Configuration Displays the configuration and status information of all detected devices.
Results Displays the results of all tests that are executed.
System health Provides the current overview of the system performance.
Event log Displays a time-stamped log of the results of all tests run on the system. This is
displayed if at least one event description is recorded.
For information about embedded system diagnostics, see the ePSA Diagnostics Guide (Notebooks,
Desktops and Servers) at dell.com/support/home.
142
7
Jumpers and connectors
System board jumper settings
For information on resetting the password jumper to disable a password, see Disabling a Forgotten
Password.
Table 8. System board jumper settings
Jumper Setting Description
PWRD_EN The password reset feature is enabled (pins 2–4).
The password reset feature is disabled (pins 4–6).
The iDRAC local access is unlocked at the next AC
power cycle.
NVRAM_CLR The configuration settings are retained at the next
system boot (pins 3–5).
The configuration settings are cleared at system
boot (pins 1–3).
143
System board connectors
Figure 52. System board connectors and jumpers
Item Connector Description
1 PCIE_G2_X1 and PCIE _G2_X4 PCIE Slot 5 (x4) and Slot 4 (x1)
2 PCIE_G3_X16 and PCIE_G3_X16 PCIE Slot 3 (next to Slot 4) and Slot 2 (next to
Slot 1)
3 PCIE_G3_X8 PCIE card Slot 1
4 BATTERY System battery connector
5 B1, B2 DIMMS for CPU2 channels 0&1
6 J-AMEA iDrac ports card connector
7 CPU2 Processor socket 2
8 B3, B4 DIMMS for CPU2 channels 2&3
9 CPU2_PWR_C (P3) CPU2 power connector
10 IDSDM Internal Dual SD Module
144
Item Connector Description
11 INTRUSION Intrusion switch connector
12 FAN6 Cooling fan 6 connector
13 A1,A5,A2,A6 DIMMS for CPU1 channels 0&1
14 FAN5 Cooling fan 5 connector
15 CPU1 Processor socket 1
16 FAN4 Cooling fan 4 connector
17 PWR_CONN B(P2) CPU1 power connector
18 A8,A4,A7,A3 DIMMS for CPU1 channels 2&3
19 FAN3 Cooling fan 3 connector
20 FAN2 Cooling fan 2 connector
21 MINI PERC C-Stack Mini PERC C-Stack connector
22 BP_SIG Backplane signal connector
23 ODD_PWR Power for the optical drive
24 SYS_PWR_CONN(P1) 24-pin power connector
25 FP_USB Front USB connector
26 SATA_CDROM Optical drive SATA connector
27 PIB_CONN Power interface board signal connector
28 SATA_TBU Tape backup unit SATA connector
29 SW_RAID_B Internal SATA B connector
30 CTRL_PNL Control panel signal connector
31 SW_RAID_A Internal SATA A connector
32 INT_ USB3.0 Internal USB3 port
33 TPM_MODULE Trusted Platform Module connector
34 J_PSWD_NVRAM Clear password / NVRAM jumpers. See
System board jumper settings.
Disabling a forgotten password
The system's software security features include a system password and a setup password. The password
jumper enables these password features or disables them and clears any password(s) currently in use.
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
145
Steps
1. Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
2. Open the system.
3. Move the jumper on the system-board jumper from pins 4 and 6 to pins 2 and 4.
4. Close the system.
The existing passwords are not disabled (erased) until the system boots with the jumper on pins 2
and 4. However, before you assign a new system and/or setup password, you must move the jumper
back to pins 4 and 6.
NOTE: If you assign a new system and/or setup password with the jumper on pins 2 and 4, the
system disables the new password(s) the next time it boots.
5. Reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
6. Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
7. Open the system.
8. Move the jumper on the system-board jumper from pins 2 and 4 to pins 4 and 6.
9. Close the system.
10. Reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
11. Assign a new system and/or setup password.
146
8
Technical specifications
Processor
Processor type One or two Intel Xeon processors E5-2600 v3
product family
Expansion Bus
Bus type PCI Express Generation 2 and PCI Express Generation 3
expansion slots with an optional riser card
Expansion slots (with optional
expansion card riser)
Riser 1 (Plug in Slot 2) (Slot 1) One full-height, full-length x16 link
(Slot 2) One full -height, half -length x8 link
NOTE: When a x16 card is installed in PCIe Slot 1 on
expansion card riser, the PCIe Slot 2 on the expansion
card will not function. The expansion card riser can be
used with either two x8 PCIe cards or with one x16 PCIe
card on PCIE slot 1.
(Slot 3) One half-length, low-profile x16
(Slot 4) One half-length, low-profile x1
(Slot 5) One half-length, low-profile x4
Expansion slots (without expansion
card riser)
(Slot 1) One half-length, low-profile x8
(Slot 2) One half-length, low-profile x16
(Slot 3) One half-length, low-profile x16
(Slot 4) One half-length, low-profile x1
(Slot 5) One half-length, low-profile x4
Memory
Architecture 1333 MT/s, 1600 MT/s, 1866 MT/s or 2133 MT/s DDR4 registered,
Error Correcting Code (ECC) Spare Rank, Single Device Data
Correction (SDDC) DIMMs
Support for advanced ECC or memory optimized operation
Memory module sockets Twelve 288-pin
147
Memory
Memory module capacities
RDIMMs 4 GB/8 GB/16 GB/32 GB
Minimum RAM 4 GB with a single processor
8 GB with a dual processor (minimum one memory module per
processor)
Maximum RAM Up to 256 GB with a single processor
Up to 384 GB with a dual processor
Power Supply Unit Capacity
Power rating per power supply unit (hot
swap)
1100 W (Platinum) AC (100-240 V, 50/60 Hz, 12 A-6.5 A)
750 W (Platinum) AC (100-240 V, 50/60 Hz, 10 A-5 A)
750 W (Platinum) DC (240 V DC, 4.5 A) *(For China only)
495 W (Platinum) AC (100-240 V, 50/60 Hz, 6.5 A-3 A)
Power rating per power supply unit (cabled) 450 W (Bronze) AC (100-240 V, 50/60 Hz, 6.5 A-3.5 A)
Heat dissipation
NOTE: Heat dissipation is calculated
using the power supply wattage rating.
1871 BTU/hr maximum (450 W power supply)
1908 BTU/hr maximum (495 W power supply)
2891 BTU/hr maximum (750 W power supply)
4100 BTU/hr maximum (1100 W power supply)
Voltage
NOTE: This system is also designed to
be connected to IT power systems with
a phase to phase voltage not exceeding
230 V.
100–240 V AC, autoranging, 50/60 Hz
Storage Controller
Storage Controller PERC H330, PERC H730, PERC H730P, PERC H830, and
12Gb SAS HBA
Drives
Hard drives Up to eight 3.5 inch or 2.5 inch, internal, hot-swappable SAS,
SATA, or Nearline SAS hard drives
SSD Up to eight 3.5 inch or 2.5 inch, internal, hot-swappable
SATA SSDs
Optical drive One optional SATA DVD-ROM drive or DVD+/-RW drive.
NOTE: DVD devices are data only.
148
Connectors
Back
NIC Four 10/100/1000 LAN ports
Serial 9-pin, DTE, 16550-compatible
USB Two USB ports, 1 USB 3.0-compliant port and 1
USB2.0–compliant port
Video 15-pin VGA
iDRAC8 one optional 1GbE Ethernet
External vFlash card One optional vFlash memory card slot with
iDRAC8 Enterprise card
NOTE: The card slot is available for use only if
the iDRAC8 Enterprise license is installed on
your system.
Front
USB Two 4-pin, USB 2.0-compliant
One USB management port/iDRAC Direct
Video 15-pin VGA
Internal
SATA Two Mini-SAS connectors
Two SATA port
USB One 9-pin, USB 3.0-compliant
Internal Dual SD Module Two optional flash memory card slots with the
internal SD module
NOTE: One card slot is dedicated for
redundancy.
Video
Video type Integrated Matrox G200
Video memory 16 MB shared
Physical
Height 8.68cm(3.41 inch)
Width 48.24 cm (18.99)
Depth 64.6 (25.43 inch) (with Bezel)
Maximum configuration weight 28.2Kg / 62lb
Empty weight 14.2Kg / 31.2lb
149
Environmental specifications
NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.
Temperature
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950
m or 3117 ft)
10°C to 35°C (50°F to 95°F) with no direct
sunlight on the equipment.
Fresh air For information on fresh air, see Expanded
Operating Temperature section.
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Relative humidity
Storage 5% to 95% RH with 33°C (91°F) maximum dew
point. Atmosphere must be non-condensing at all
times.
Operating 10% to 80% Relative Humidity with 29°C (84.2°F)
maximum dew point.
Maximum vibration
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation
orientations).
Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six
sides tested).
Maximum shock
Operating Six consecutively executed shock pulses in the
positive and negative x, y, and z axes of 40 G for
up to 2.3 ms.
Storage Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2
ms.
Maximum altitude
Operating 3048 m (10,000 ft).
Storage 12,000 m (39,370 ft).
Operating temperature de-rating
Up to 35 °C (95 °F) Maximum temperature is reduced by 1°C/300 m
(1°F/547 ft) above 950 m (3,117 ft).
35 °C to 40 °C (95 °F to 104 °F) Maximum temperature is reduced by 1°C/175 m
(1°F/319 ft) above 950 m (3,117 ft).
150
Environmental specifications
40 °C to 45 °C (104 °F to 113 °F) Maximum temperature is reduced by 1°C/125 m
(1°F/228 ft) above 950 m (3,117 ft).
Particulate contamination
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from
particulates and gaseous contamination. If it is determined that levels of particulates or gaseous
pollution are beyond the limits specified below and are the reason for the damage and/or failures
to your equipment, it may be necessary for you to re-mediate the environmental conditions that
are causing the damage and/or failures. Re-mediation of environmental conditions will be the
responsibility of the customer.
Air filtration
NOTE: Applies to data center environments
only. Air filtration requirements do not
apply to IT equipment designed to be used
outside a data center, in environments such
as an office or factory floor.
Data center air filtration as defined by ISO Class 8
per ISO 14644-1 with a 95% upper confidence
limit.
NOTE: Air entering the data center must
have MERV11 or MERV13 filtration.
Conductive dust
NOTE: Applies to data center and non-data
center environments.
Air must be free of conductive dust, zinc whiskers,
or other conductive particles.
Corrosive dust
NOTE: Applies to data center and non-data
center environments.
• Air must be free of corrosive dust.
• Residual dust present in the air must have a
deliquescent point less than 60% relative
humidity.
Gaseous contamination
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/
ISA71.04-1985.
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.
Expanded operating temperature
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be
reported on the LCD and in the System Event Log.
Continuous operation 5°C to 40°C at 5% to 85% RH with 29°C dew point.
NOTE: Outside the standard operating
temperature (10°C to 35°C), the system can
operate continuously down to 5°C or as high
as 40°C.
151
Expanded operating temperature
For temperatures between 35°C and 40°C, de-
rate maximum allowable temperature by 1°C per
175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C dew
point.
NOTE: Outside the standard operating
temperature (10°C to 35°C), the system can
operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40°C and 45°C, de-
rate maximum allowable temperature by 1°C per
125 m above 950 m (1°F per 228 ft).
Expanded Operating Temperature Restrictions • Do not perform a cold startup below 5°C.
• The operating temperature specified is for a
maximum altitude of 3050 m (10,000 ft).
• Only support TDP to 120W
• Tape Backup Unit (TBU) is not supported in
Fresh Air.
• Redundant power supplies are required.
• Non Dell qualified peripheral cards and/or
peripheral cards greater than 25 W are not
supported.
• PCIe SSD is not supported.
152
9
Getting help
Contacting Dell
Dell provides several online and telephone-based support and service options. If you do not have an
active Internet connection, you can find contact information on your purchase invoice, packing slip, bill,
or Dell product catalog. Availability varies by country and product, and some services may not be
available in your area. To contact Dell for sales, technical support, or customer-service issues:
1. Go to dell.com/support.
2. Select your country from the drop-down menu on the bottom right corner of the page.
3. For customized support:
a. Enter your system Service Tag in the Enter your Service Tag field.
b. Click Submit.
The support page that lists the various support categories is displayed.
4. For general support:
a. Select your product category.
b. Select your product segment.
c. Select your product.
The support page that lists the various support categories is displayed.
Locating your system Service Tag
Your system is identified by a unique Express Service Code and Service Tag number. The Express Service
Code and Service Tag are found on the front of the system by pulling out the information tag.
Alternatively, the information may be on a sticker on the chassis of the system. This information is used
by Dell to route support calls to the appropriate personnel.
Documentation feedback
If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you
can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit
to send your feedback.
Quick Resource Locator (QRL)
Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to
videos. This can be done by visiting www.dell.com/QRL or by using your smartphone or tablet and a
model specific Quick Resource (QR) code located on your Dell PowerEdge system. To try out the QR
code, scan the following image.
153
154