Table of Contents
- Dell PowerEdge R630 Owner's Manual
- About your system
- Performing initial system configuration
- Pre-operating system management applications
- Navigation keys
- About System Setup
- Entering System Setup
- System Setup Main Menu
- System BIOS screen
- System Information screen details
- Memory Settings screen details
- Processor Settings screen details
- SATA Settings screen details
- Boot Settings screen details
- Network Settings screen details
- Integrated Devices screen details
- Serial Communication screen details
- System Profile Settings screen details
- System Security settings screen details
- Miscellaneous Settings screen details
- About Boot Manager
- Changing the boot order
- Choosing the system boot mode
- Assigning a system and setup password
- Deleting or changing an existing system password and setup password
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Front bezel (optional)
- Removing the system cover
- Installing the system cover
- Inside the system
- Cooling shroud
- System memory
- Hard drives
- Removing a 2.5 inch hard-drive blank
- Installing a 2.5 inch hard-drive blank
- Removing a 1.8 inch hard-drive blank
- Installing a 1.8 inch hard-drive blank
- Removing a hot-swap hard drive
- Installing a hot-swap hard drive
- Removing a hard drive from a hard-drive carrier
- Installing a hard drive into a hard-drive carrier
- Removing a 1.8 inch hard drive from a hard-drive carrier
- Installing a 1.8 inch hard drive into a hard-drive carrier
- Optical drive (optional)
- Cooling fans
- Internal USB memory key (optional)
- Expansion cards and expansion-card risers
- SD vFlash media card
- Internal dual SD module
- Internal SD card
- Integrated storage controller card
- Network daughter card
- Processors
- Power supply units
- System battery
- Hard-drive backplane
- Control Panel Assembly
- Removing the control panel board–8 hard drive system
- Installing the control panel board–8 hard drive system
- Removing the control panel–8 hard–drive system
- Installing the control panel–8 hard drive system
- Removing the control panel–10 hard–drive and 24–hard drive system
- Installing the control panel–10 hard–drive system and 24 hard–drive system
- VGA Module
- System board
- Trusted Platform Module
- Troubleshooting your system
- Safety first—for you and your system
- Troubleshooting system startup failure
- Troubleshooting external connections
- Troubleshooting the video subsystem
- Troubleshooting a USB device
- Troubleshooting iDRAC Direct (USB XML configuration)
- Troubleshooting iDRAC Direct (laptop connection)
- Troubleshooting a serial I/O device
- Troubleshooting a NIC
- Troubleshooting a wet system
- Troubleshooting a damaged system
- Troubleshooting the system battery
- Troubleshooting power supply units
- Troubleshooting cooling problems
- Troubleshooting cooling fans
- Troubleshooting system memory
- Troubleshooting an internal USB key
- Troubleshooting an SD card
- Troubleshooting an optical drive
- Troubleshooting a tape backup unit
- Troubleshooting a hard drive
- Troubleshooting a storage controller
- Troubleshooting expansion cards
- Troubleshooting processors
- System messages
- Using system diagnostics
- Jumpers and connectors
- Technical specifications
- Getting help
DELL R630 User Manual
Displayed below is the user manual for R630 by DELL which is a product in the Servers category. This manual has pages.
Related Manuals
Dell PowerEdge R630
Owner's Manual
Regulatory Model: E26S Series
Regulatory Type: E26S001
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you
how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and
intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other
jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2014 - 09
Rev. A00
Contents
1 About your system................................................................................................ 8
Supported configurations..................................................................................................................... 8
Front-panel features and indicators.....................................................................................................8
LCD panel features.............................................................................................................................. 13
Home screen................................................................................................................................. 14
Setup menu....................................................................................................................................14
View menu..................................................................................................................................... 15
Diagnostic indicators...........................................................................................................................15
Hard-drive indicator codes................................................................................................................. 17
iDRAC Direct LED indicator codes......................................................................................................18
Quick Sync indicator codes................................................................................................................ 19
Back-panel features and indicators................................................................................................... 20
NIC indicator codes............................................................................................................................ 23
Power indicator codes........................................................................................................................23
Documentation matrix........................................................................................................................26
Quick Resource Locator .............................................................................................................. 27
2 Performing initial system configuration ....................................................... 28
Setting up your system....................................................................................................................... 28
Methods of setting up and configuring the iDRAC IP address .........................................................28
Information about logging in to iDRAC............................................................................................. 29
Methods of installing the operating system.......................................................................................29
Remote management ........................................................................................................................29
Downloading and installing drivers and firmware............................................................................. 29
3 Pre-operating system management applications........................................ 31
Navigation keys....................................................................................................................................31
About System Setup............................................................................................................................32
Entering System Setup.................................................................................................................. 32
System Setup Main Menu..............................................................................................................32
System BIOS screen...................................................................................................................... 32
System Information screen details............................................................................................... 33
Memory Settings screen details....................................................................................................34
Processor Settings screen details................................................................................................. 35
SATA Settings screen details.........................................................................................................36
Boot Settings screen details..........................................................................................................39
Network Settings screen details................................................................................................... 40
Integrated Devices screen details................................................................................................ 40
Serial Communication screen details...........................................................................................42
System Profile Settings screen details..........................................................................................42
System Security settings screen details........................................................................................44
Miscellaneous Settings screen details..........................................................................................46
About Boot Manager...........................................................................................................................47
Entering Boot Manager ................................................................................................................ 47
Boot Manager main menu............................................................................................................ 47
Changing the boot order.................................................................................................................... 47
Choosing the system boot mode...................................................................................................... 48
Assigning a system and setup password............................................................................................48
Deleting or changing an existing system password and setup password........................................49
4 Installing and removing system components...............................................50
Safety instructions...............................................................................................................................50
Before working inside your system....................................................................................................50
After working inside your system....................................................................................................... 50
Recommended tools...........................................................................................................................51
Front bezel (optional).......................................................................................................................... 51
Removing the front bezel..............................................................................................................51
Installing the front bezel............................................................................................................... 52
Removing the system cover............................................................................................................... 52
Installing the system cover................................................................................................................. 53
Inside the system.................................................................................................................................54
Cooling shroud................................................................................................................................... 56
Removing the cooling shroud...................................................................................................... 56
Installing the cooling shroud........................................................................................................ 57
System memory...................................................................................................................................57
General memory module installation guidelines.........................................................................59
Mode-specific guidelines..............................................................................................................59
Sample memory configurations....................................................................................................61
Removing memory modules........................................................................................................ 63
Installing memory modules.......................................................................................................... 65
Hard drives.......................................................................................................................................... 66
Removing a 2.5 inch hard-drive blank..........................................................................................67
Installing a 2.5 inch hard-drive blank............................................................................................67
Removing a 1.8 inch hard-drive blank......................................................................................... 68
Installing a 1.8 inch hard-drive blank........................................................................................... 68
Removing a hot-swap hard drive................................................................................................. 69
Installing a hot-swap hard drive....................................................................................................71
Removing a hard drive from a hard-drive carrier.........................................................................71
Installing a hard drive into a hard-drive carrier............................................................................ 72
Removing a 1.8 inch hard drive from a hard-drive carrier...........................................................72
Installing a 1.8 inch hard drive into a hard-drive carrier.............................................................. 73
Optical drive (optional)........................................................................................................................73
Removing the optical drive........................................................................................................... 73
Installing the optical drive............................................................................................................. 74
Removing the slim optical drive blank..........................................................................................75
Installing the slim optical drive blank............................................................................................76
Cooling fans........................................................................................................................................ 76
Removing a cooling fan.................................................................................................................77
Installing a cooling fan.................................................................................................................. 78
Internal USB memory key (optional).................................................................................................. 78
Replacing the internal USB key.....................................................................................................78
Expansion cards and expansion-card risers.......................................................................................79
Expansion card installation guidelines..........................................................................................79
Removing an expansion card....................................................................................................... 80
Installing an expansion card..........................................................................................................81
Removing expansion-card risers..................................................................................................82
Installing expansion card risers.....................................................................................................84
SD vFlash media card..........................................................................................................................85
Replacing a SD vFlash card...........................................................................................................85
Internal dual SD module..................................................................................................................... 85
Removing the internal dual SD module ...................................................................................... 86
Installing the internal dual SD module ........................................................................................ 88
Internal SD card.................................................................................................................................. 88
Removing an internal SD Card..................................................................................................... 88
Installing an internal SD card........................................................................................................89
Integrated storage controller card.....................................................................................................89
Removing the integrated storage controller card....................................................................... 89
Installing the integrated storage controller card..........................................................................91
Network daughter card....................................................................................................................... 91
Removing the network daughter card..........................................................................................91
Installing the network daughter card........................................................................................... 93
Processors........................................................................................................................................... 93
Removing a processor.................................................................................................................. 93
Installing a processor.................................................................................................................... 97
Power supply units..............................................................................................................................99
Hot Spare feature.......................................................................................................................... 99
Removing the power supply unit blank..................................................................................... 100
Installing the power supply unit blank........................................................................................101
Removing an AC power supply unit........................................................................................... 101
Installing an AC power supply unit.............................................................................................102
Wiring instructions for a DC power supply unit.........................................................................103
Removing a DC power supply unit.............................................................................................104
Installing a DC power supply unit...............................................................................................105
System battery...................................................................................................................................105
Replacing the system battery......................................................................................................105
Hard-drive backplane........................................................................................................................107
Removing the hard-drive backplane.......................................................................................... 107
Installing the hard-drive backplane.............................................................................................113
Control Panel Assembly.................................................................................................................... 114
Removing the control panel board–8 hard drive system..........................................................114
Installing the control panel board–8 hard drive system............................................................ 115
Removing the control panel–8 hard–drive system................................................................... 116
Installing the control panel–8 hard drive system.......................................................................117
Removing the control panel–10 hard–drive and 24–hard drive system..................................118
Installing the control panel–10 hard–drive system and 24 hard–drive system....................... 119
VGA Module...................................................................................................................................... 120
Removing the VGA module........................................................................................................ 120
Installing the VGA module...........................................................................................................121
System board.....................................................................................................................................122
Removing the system board....................................................................................................... 122
Installing the system board.........................................................................................................124
Trusted Platform Module..................................................................................................................126
Installing the Trusted Platform Module .....................................................................................126
Re-enabling the TPM for BitLocker users...................................................................................127
Re-enabling the TPM for TXT users............................................................................................127
5 Troubleshooting your system........................................................................ 129
Safety first—for you and your system...............................................................................................129
Troubleshooting system startup failure........................................................................................... 129
Troubleshooting external connections............................................................................................129
Troubleshooting the video subsystem.............................................................................................129
Troubleshooting a USB device......................................................................................................... 129
Troubleshooting iDRAC Direct (USB XML configuration)............................................................... 130
Troubleshooting iDRAC Direct (laptop connection)........................................................................131
Troubleshooting a serial I/O device..................................................................................................131
Troubleshooting a NIC...................................................................................................................... 131
Troubleshooting a wet system......................................................................................................... 132
Troubleshooting a damaged system................................................................................................133
Troubleshooting the system battery................................................................................................ 133
Troubleshooting power supply units............................................................................................... 134
Power source problems..............................................................................................................134
Power supply unit problems....................................................................................................... 134
Troubleshooting cooling problems..................................................................................................135
Troubleshooting cooling fans...........................................................................................................135
Troubleshooting system memory.................................................................................................... 136
Troubleshooting an internal USB key............................................................................................... 137
Troubleshooting an SD card............................................................................................................. 137
Troubleshooting an optical drive..................................................................................................... 138
Troubleshooting a tape backup unit................................................................................................ 138
Troubleshooting a hard drive........................................................................................................... 139
Troubleshooting a storage controller..............................................................................................140
Troubleshooting expansion cards....................................................................................................140
Troubleshooting processors............................................................................................................. 141
System messages.............................................................................................................................. 142
Warning messages...................................................................................................................... 142
Diagnostic messages...................................................................................................................142
Alert messages.............................................................................................................................142
6 Using system diagnostics................................................................................143
Dell Embedded System Diagnostics.................................................................................................143
When to use the Embedded System Diagnostics......................................................................143
Running the Embedded System Diagnostics from Boot Manager............................................143
Running the Embedded System Diagnostics from the Dell Lifecycle Controller.....................143
System diagnostic controls.........................................................................................................144
7 Jumpers and connectors................................................................................ 145
System board jumper settings.......................................................................................................... 145
System board connectors.................................................................................................................146
Disabling a forgotten password........................................................................................................148
8 Technical specifications..................................................................................149
9 Getting help.......................................................................................................155
Contacting Dell..................................................................................................................................155
Locating your system service tag..................................................................................................... 155
Documentation feedback................................................................................................................. 155
Quick Resource Locator .................................................................................................................. 155
1
About your system
The Dell PowerEdge R630 is a rack server that support up to two processors based on the Intel Xeon
E5-2600 v3 processor family, up to 24 DIMMs, and storage capacity of up to 28 drive slots.
NOTE: The Dell PowerEdge R630 system supports only internal, hot-swappable hard drives.
Supported configurations
PowerEdge R630 Systems Configurations
Eight-hard-drive systems Up to eight 2.5 inch hard drives
Ten-hard-drive systems Up to ten 2.5 inch hard drives
Twenty four-hard-drive systems Up to twenty four 1.8 hard drives
Front-panel features and indicators
Figure 1. Front-panel features and indicators–8 hard-drive system
Item Indicator, Button, or
Connector Icon Description
1 Power-on indicator,
power button
The power-on indicator lights when the system
power is on. The power button controls the power
supply output to the system.
8
Item Indicator, Button, or
Connector Icon Description
NOTE: On ACPI-compliant operating systems,
turning off the system using the power button
causes the system to perform a graceful
shutdown before power to the system is
turned off.
2 NMI button Used to troubleshoot software and device driver
errors when running certain operating systems.
This button can be pressed using the end of a
paper clip.
Use this button only if directed to do so by
qualified support personnel or by the operating
system documentation.
3 System identification
button
The identification buttons on the front and back
panels can be used to locate a particular system
within a rack. When one of these buttons is
pressed, the LCD panel on the front and the
system status indicator on the back flashes blue
until one of the buttons is pressed again.
Press to toggle the system ID to ON or OFF. If the
system stops responding during POST, press and
hold the system ID button for more than five
seconds to enter BIOS progress mode.
To reset the iDRAC (if not disabled in F2 iDRAC
setup) press and hold the button for more than 15
seconds.
4 USB management port/
iDRAC Direct (2)
Allows you to connect USB devices to the system
or provides access to the iDRAC Direct features.
For more information, see the Integrated Dell
Remote Access Controller User's Guide at
dell.com/esmmanuals. The ports are USB 2.0-
compliant.
5 Optical drive (optional) One optional SATA DVD-ROM drive or DVD+/-RW
drive.
NOTE: DVD devices are data only.
6 SD vFlash media card
slot
Allows you to insert a vFlash media card.
7 LCD menu buttons Allows you to navigate the control panel LCD
menu.
8 Information tag A slide-out label panel, which allows you to record
system information, such as Service Tag, NIC, and
MAC address.
9
Item Indicator, Button, or
Connector Icon Description
9 LCD panel Displays system ID, status information, and system
error messages. The LCD lights blue during normal
system operation. When the system needs
attention, the LCD lights amber and the LCD panel
displays an error code followed by descriptive text.
NOTE: If the system is connected to AC
power and an error is detected, the LCD lights
amber regardless of whether the system is
turned on or off.
10 Video connector Allows you to connect a VGA display to the
system.
11 Hard drives (8) Up to eight 2.5 inch hot-swappable hard drives.
12. Quick Sync Indicates a Quick Sync enabled system. The Quick
Sync feature is optional and requires a Quick Sync
bezel. This feature allows management of the
system using mobile devices. This feature
aggregates hardware/firmware inventory and
various system level diagnostic/error information
that can be used in troubleshooting the system.
For more information, see the Integrated Dell
Remote Access Controller User’s Guide at
dell.com/esmmanuals.
Figure 2. Front-panel features and indicators–10 hard-drive system
Item Indicator, Button, or
Connector Icon Description
1 Diagnostic indicators The diagnostic indicators light up to display error
status.
2 System health indicator The system health indicator blinks amber when a
system fault is detected.
10
Item Indicator, Button, or
Connector Icon Description
3 Power-on indicator,
power button
The power-on indicator lights when the system
power is on. The power button controls the power
supply output to the system.
NOTE: On ACPI-compliant operating systems,
turning off the system using the power button
causes the system to perform a graceful
shutdown before power to the system is
turned off.
4 NMI button Used to troubleshoot software and device driver
errors when running certain operating systems.
This button can be pressed using the end of a
paper clip.
Use this button only if directed to do so by
qualified support personnel or by the operating
system documentation.
5 System identification
button
The identification buttons on the front and back
panels can be used to locate a particular system
within a rack. When one of these buttons is
pressed, the system status indicator on the back
flashes until one of the buttons is pressed again.
Press to toggle the system ID on and off.
If the system stops responding during POST, press
and hold the system ID button for more than five
seconds to enter BIOS progress mode.
To reset the iDRAC (if not disabled in F2 iDRAC
setup) press and hold the button for more than 15
seconds.
6 Mini USB connector/
iDRAC Direct
Allows you to connect USB devices to the system
or provides access to the iDRAC Direct features.
For more information, see the Integrated Dell
Remote Access Controller User's Guide at
dell.com/esmmanuals. The port is USB 2.0-
compliant.
7 Information tag A slide-out label panel, which allows you to record
system information, such as Service Tag, NIC, and
MAC address as per your need.
8 Hard drives (10) Up to ten 2.5 inch hot-swappable hard drives. Up
to six 2.5 hot-swappable hard drives and up to four
2.5 inch Dell PowerEdge Express Flash devices
(PCIe SSDs).
9 Quick Sync Indicates a Quick Sync enabled system. The Quick
Sync feature is optional and requires a Quick Sync
11
Item Indicator, Button, or
Connector Icon Description
bezel. This feature allows management of the
system using mobile devices. This feature
aggregates hardware/firmware inventory and
various system level diagnostic/error information
that can be used in troubleshooting the system.
For more information, see the Integrated Dell
Remote Access Controller User’s Guide at
dell.com/esmmanuals.
Figure 3. Front-panel features and indicators–24 hard-drive system
Item Indicator, Button, or
Connector Icon Description
1 Diagnostic indicators The diagnostic indicators light up to display error
status.
2 System health indicator The system health indicator blinks amber when a
system fault is detected.
3 Power-on indicator,
power button
The power-on indicator lights when the system
power is on. The power button controls the
power supply output to the system.
NOTE: On ACPI-compliant operating
systems, turning off the system using the
power button causes the system to perform
a graceful shutdown before power to the
system is turned off.
4 NMI button Used to troubleshoot software and device driver
errors when running certain operating systems.
This button can be pressed using the end of a
paper clip.
12
Item Indicator, Button, or
Connector Icon Description
Use this button only if directed to do so by
qualified support personnel or by the operating
system documentation.
5 System identification
button
The identification buttons on the front and back
panels can be used to locate a particular system
within a rack. When one of these buttons is
pressed, the system status indicator on the back
flashes until one of the buttons is pressed again.
Press to toggle the system ID on and off.
If the system stops responding during POST, press
and hold the system ID button for more than five
seconds to enter BIOS progress mode.
To reset the iDRAC (if not disabled in F2 iDRAC
setup) press and hold the button for more than 15
seconds.
6 Mini USB connector Allows you to connect USB devices to the system
or provides access to the iDRAC Direct features.
For more information, see the Integrated Dell
Remote Access Controller User's Guide at
dell.com/esmmanuals. The port is USB 2.0-
compliant.
7 Information tag A slide-out label panel, which allows you to
record system information, such as Service Tag,
NIC, MAC address, and so on as per your need.
8 Hard drives (24) Up to 24 1.8 inch hot-swappable hard drives.
9 Quick Sync Indicates a Quick Sync enabled system. The
Quick Sync feature is optional and requires a
Quick Sync bezel. This feature allows
management of the system using mobile devices.
This feature aggregates hardware/firmware
inventory and various system level diagnostic/
error information that can be used in
troubleshooting the system. For more
information, see the Integrated Dell Remote
Access Controller User’s Guide at dell.com/
esmmanuals.
LCD panel features
The LCD panel of your system provides system information and status and error messages to indicate if
the system is operating correctly or if the system needs attention. For more information on error
messages, see the Dell Event and Error Messages Reference Guide at dell.com/esmmanuals.
• The LCD backlight lights blue during normal operating conditions and lights amber to indicate an
error condition.
13
• The LCD backlight is off when the system is in standby mode and can be turned on by pressing either
the Select, Left, or Right button on the LCD panel.
• The LCD backlight remains off if LCD messaging is turned off through the iDRAC utility, the LCD
panel, or other tools.
Figure 4. LCD panel features
Item Button Description
1 Left Moves the cursor back in one-step increments.
2 Select Selects the menu item highlighted by the cursor.
3 Right Moves the cursor forward in one-step increments.
During message scrolling:
• Press and hold the button to increase scrolling speed.
• Release the button to stop.
NOTE: The display will stop scrolling when the button is
released. After 45 seconds of inactivity the display will start
scrolling.
Home screen
The Home screen displays user-configurable information about the system. This screen is displayed
during normal system operation when there are no status messages or errors. When the system is in
standby mode, the LCD backlight turns off after five minutes of inactivity if there are no error messages.
Press one of the three navigation buttons (Select, Left, or Right) to view the Home screen.
To navigate to the Home screen from another menu, continue to select the up arrow until the Home
icon is displayed, and then select the Home icon.
From the Home screen, press the Select button to enter the main menu.
Setup menu
NOTE: When you select an option in the Setup menu, you must confirm the option before
proceeding to the next action.
14
Option Description
iDRAC Select DHCP or Static IP to configure the network mode. If Static IP is selected,
the available fields are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to
enable DNS and to view domain addresses. Two separate DNS entries are available.
Set error Select SEL to display LCD error messages in a format that matches the IPMI
description in the SEL. This is useful when trying to match an LCD message with an
SEL entry.
Select Simple to display LCD error messages in a simplified user-friendly
description. For more information on error messages, see the Dell Event and Error
Messages Reference Guide at dell.com/esmmanuals.
Set home Select the default information to be displayed on the LCD Home screen. See View
menu to see the options and option items that can be set as the default on the
Home screen.
View menu
NOTE: When you select an option in the View menu, you must confirm the option before
proceeding to the next action.
Option Description
iDRAC IP Displays the IPv4 or IPv6 addresses for iDRAC8. Addresses include DNS (Primary
and Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).
MAC Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Name Displays the name of the Host, Model, or User String for the system.
Number Displays the Asset tag or the Service tag for the system.
Power Displays the power output of the system in BTU/hr or Watts. The display format can
be configured in the Set home submenu of the Setup menu.
Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format
can be configured in the Set home submenu of the Setup menu.
Diagnostic indicators
The diagnostic indicators on the system front panel display error status during system startup.
NOTE: The diagnostic indicators are not present if the system is equipped with an LCD display.
NOTE: The diagnostic indicators are present only on the 10-hard drive and the 24–hard drive
systems.
NOTE: No diagnostic indicators are lit when the system is switched off. To start the system, plug it
into a working power source and press the power button.
15
Icon Description Condition Corrective action
Health
indicator
If the system is on, and in
good health, the indicator
lights solid blue.
None required.
The indicator blinks amber if
the system is on or in
standby, and if any error
exists (for example, a failed
fan or hard drive).
See the System Event Log or system
messages for the specific issue. For more
information on error messages, see the Dell
Event and Error Messages Reference Guide
at dell.com/esmmanuals.
Invalid memory configurations can cause
the system to halt at startup without any
video output. See Getting help.
Hard-drive
indicator
The indicator blinks amber if
a hard drive experiences an
error.
See the System Event Log to determine the
hard drive that has an error. Run the
appropriate Online Diagnostics test. Restart
system and run embedded diagnostics
(ePSA). If the hard drives are configured in a
RAID array, restart the system and enter the
host adapter configuration utility program.
Electrical
indicator
The indicator blinks amber if
the system experiences an
electrical error (for example,
voltage out of range, or a
failed power supply or
voltage regulator).
See the System Event Log or system
messages for the specific issue. If it is due to
a problem with the power supply, check the
LED on the power supply. Re-seat the
power supply by removing and reinstalling
it. If the problem persists, see Getting help.
Temperatur
e indicator
The indicator blinks amber if
the system experiences a
thermal error (for example, a
temperature out of range or
fan failure).
Ensure that none of the following
conditions exist:
• A cooling fan is removed or has failed.
• System cover, cooling shroud, EMI filler
panel, memory-module blank, or back-
filler bracket is removed.
• Ambient temperature is too high.
• External airflow is obstructed.
See Getting help.
Memory
indicator
The indicator blinks amber if
a memory error occurs.
See the system event log or system
messages for the location of the failed
memory. Reinstall the memory device. If the
problem persists, see Getting help.
PCIe
indicator
The indicator blinks amber if
a PCIe card experiences an
error.
Restart the system. Update any required
drivers for the PCIe card. Re-install the card.
If the problem persists, see Getting help.
NOTE: For more information on
supported PCIe cards, see Expansion
Card Installation Guidelines.
16
Hard-drive indicator codes
Figure 5. Hard-drive indicators
1. hard-drive activity indicator 2. hard-drive status indicator
3. hard drive
NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator
(on the right side) does not function and remains off.
Drive-status indicator pattern (RAID only) Condition
Blinks green two times per second Identifying drive or preparing for removal.
Off Drive ready for insertion or removal.
NOTE: The drive status indicator remains off until
all hard drives are initialized after the system is
turned on. Drives are not ready for insertion or
removal during this time.
Blinks green, amber, and turns off Predicted drive failure
Blinks amber four times per second Drive failed
Blinks green slowly Drive rebuilding
Steady green Drive online
Blinks green three seconds, amber three
seconds, and turns off six seconds
Rebuild aborted
17
iDRAC Direct LED indicator codes
NOTE: The iDRAC Direct LED indicator does not light up for the USB mode.
Figure 6. iDRAC Direct LED indicator
1. iDRAC Direct status indicator
The table below displays iDRAC Direct activity when configuring iDRAC Direct by using the management
port (USB XML Import).
Convention iDRAC Direct
LED indicator
pattern
Condition
A Green Lights green for a minimum of 2 seconds at the beginning and end
of a file transfer.
B Flashing green Indicates file transfer or any operation tasks.
C Green and turns
off
Indicates that the file transfer is complete.
D Not lit Indicates that the USB is ready to be removed or that a task is
complete.
The table below displays iDRAC Direct activity when configuring iDRAC Direct using your laptop and
cable (Laptop Connect).
iDRAC Direct LED
indicator pattern Condition
Solid green for two
seconds
Indicates that the laptop is connected.
Flashing green (on
for two seconds and
off for two seconds)
Indicates that the laptop connected is recognized.
Turns off Indicates that the laptop is unplugged..
18
Quick Sync indicator codes
Figure 7. Quick Sync indicator codes
1. Quick Sync status indicator 2. Quick Sync activation button
Power indicator pattern Condition
Slow blink Quick Sync is waiting to be configured from iDRAC.
Solid Quick Sync is ready to transfer.
Blinks three times rapidly and then turns off Quick Sync feature is disabled from iDRAC.
Blinks continuously when the mobile device
touches the antenna
Indicates data transfer activity.
Blinks rapidly five times and turns off for one
second when the activation button is pressed.
This pattern is repeated until the activation
button is pressed again.
Quick Sync hardware is not responding properly.
Reseat the bezel. the problem persists, see Getting
help.
Off Indicates that the Quick Sync feature is turned off.
Use the activation button to activate it. If pressing the
activation button does not turn on the LEDs, it
indicates that power is not delivered to the Quick
Sync bezel.
NOTE: For security purposes, Quick Sync turns
off after thirty seconds of in-activity after the
activation button is pressed. Once timed-out,
the user is expected to press the activation
button again to activate Quick Sync.
19
Back-panel features and indicators
Figure 8. Back-panel features and indicators—8 hard-drive system (2 PCIe expansion cards)
Item Indicator, Button, or
Connector Icon Description
1 System identification
button
The identification buttons on the front and back
panels can be used to locate a particular system
within a rack. When one of these buttons is
pressed, the LCD panel on the front and the
system status indicator on the back blink until one
of the buttons is pressed again.
Press to toggle the system ID on and off. If the
system stops responding during POST, press and
hold the system ID button for more than five
seconds to enter BIOS progress mode.
To reset iDRAC (if not disabled in F2 iDRAC setup)
press and hold for more than 15 seconds.
2 System identification
connector
Allows you to connect the optional system status
indicator assembly through the optional cable
management arm.
3 iDRAC8 Enterprise port Dedicated management port.
NOTE: The port is available for use only if the
iDRAC87 Enterprise license is installed on your
system.
4 PCIe expansion card slot
(riser 1)
Allows you to connect a low profile PCIe
expansion card.
5 Serial connector Allows you to connect a serial device to the
system.
6 Video connector Allows you to connect a VGA display to the system.
7 USB connectors (2) Allows you to connect USB devices to the system.
The ports are USB 3.0-compliant.
20
Item Indicator, Button, or
Connector Icon Description
8 PCIe expansion card slot
(riser 2)
Allows you to connect a full height three-fourth
length PCIe expansion card.
9 Ethernet connectors (4) Four integrated 10/100/1000 Mbps NIC
connectors
or
Four integrated connectors:
• Two integrated 10/100/1000 Mbps NIC
connectors
• Two integrated 100 Mbps/1 Gbps/10 Gbps SFP
+ connectors
10 Power supply (PSU1) AC 495 W, 750 W, or 1100 W
Or
DC 750 W or 1100 W
11 Power supply (PSU2)
Figure 9. Back-panel features and indicators—24 hard-drive system, 10 hard-drive system, and 8 hard-drive
system (3 PCIe expansion cards)
Item Indicator, Button, or
Connector Icon Description
1 System identification
button
The identification buttons on the front and back
panels can be used to locate a particular system
within a rack.
10/24 Hard-
Drive System
When one of these buttons
is pressed, the system status
indicator on the back flashes
until one of the buttons is
pressed again.
8 Hard-Drive
System
When one of these buttons
is pressed, the LCD panel on
the front and the system
status indicator on the back
21
Item Indicator, Button, or
Connector Icon Description
flashes until one of the
buttons is pressed again.
Press to toggle the system ID on and off. If the
system stops responding during POST, press and
hold the system ID button for more than five
seconds to enter BIOS progress mode.
To reset iDRAC (if not disabled in F2 iDRAC setup)
press and hold for more than 15 seconds.
2 System identification
connector
Allows you to connect the optional system status
indicator assembly through the optional cable
management arm.
3 iDRAC8 Enterprise port Dedicated management port.
NOTE: The port is available for use only if the
iDRAC8 Enterprise license is installed on your
system.
4 LP PCIe expansion card
slot (riser 1)
Allows you to connect a low profile PCIe
expansion card.
5 Serial connector Allows you to connect a serial device to the
system.
6 LP PCIe expansion card
slot (riser 2)
Allows you to connect a low profile PCIe
expansion card.
7 Video connector Allows you to connect a VGA display to the system.
8 USB connectors (2) Allows you to connect USB devices to the system.
The ports are USB 3.0-compliant.
9 LP PCIe expansion card
slot (riser 3)
Allows you to connect a LP PCIe expansion card.
10 Ethernet connectors (4) Four integrated 10/100/1000 Mbps NIC
connectors
or
Four integrated connectors:
• Two integrated 10/100/1000 Mbps NIC
connectors
• Two integrated 100 Mbps/1 Gbps/10 Gbps SFP
+ connectors
11 Power supply (PSU1) AC 495 W, 750 W, or 1100 W
Or
DC 750 W or 1100 W
12 Power supply (PSU2)
22
NIC indicator codes
Figure 10. NIC indicators
1. link indicator 2. activity indicator
Indicator Indicator code
Link and activity indicators are off The NIC is not connected to the network.
Link indicator is green The NIC is connected to a valid network at its
maximum port speed (1 Gbps or 10 Gbps).
Link indicator is amber The NIC is connected to a valid network at less
than its maximum port speed.
Activity indicator is blinking green Network data is being sent or received.
Power indicator codes
Each AC power supply unit (PSU) has an illuminated translucent handle and each DC power supply unit
(when available) has an LED that serves as an indicator to show whether power is present or a power fault
has occurred.
23
Figure 11. AC power supply unit status indicator
1. AC power supply unit status indicator/handle
Convention Power indicator
pattern Condition
A Green The handle indicator lights green indicating that a valid power
source is connected to the power supply unit and that the power
supply unit is operational.
B Flashing green When updating the firmware of the power supply unit, the power
supply unit handle flashes green.
C Flashing green
and turns off
When hot-adding a power supply unit (PSU), the power supply unit
handle flashes green five times at 4 Hz rate and turns off. This
indicates that the power supply unit is mismatched with the other
power supply unit (in terms of efficiency, feature set, health status,
and supported voltage). Replace the power supply unit that has the
flashing indicator with a power supply unit that matches the capacity
of the other installed power supply unit.
NOTE: For AC power supplies, use only PSUs with the Extended
Power Performance (EPP) label on the back. Mixing PSUs from
previous generations of servers can result in a PSU mismatch
condition or failure to power on.
D Flashing amber Indicates a problem with the power supply unit.
24
Convention Power indicator
pattern Condition
CAUTION: When correcting a power supply unit mismatch,
replace only the power supply unit with the flashing indicator.
Swapping the opposite power supply unit to make a matched
pair can result in an error condition and unexpected system
shutdown. To change from a High Output configuration to a
Low Output configuration or vice versa, you must power
down the system.
CAUTION: AC power supplies support both 220 V and 110 V
input voltages with the exception of Titanium power supplies,
which support only 220 V. When two identical power supplies
receive different input voltages, they can output different
wattages, and trigger a mismatch.
CAUTION: If two power supplies are used, they must be of the
same type and have the same maximum output power.
CAUTION: Combining AC and DC power supplies is not
supported and triggers a mismatch.
E Not lit Power is not connected.
Figure 12. DC power supply unit status indicator
1. DC power supply unit status indicator
25
Convention Power indicator
pattern Condition
A Green The handle/LED indicator lights green indicating that a valid power
source is connected to the power supply unit and that the power
supply unit is operational.
B Flashing green When hot-adding a power supply unit, power supply unit LED
flashes green. This indicates that the power supply unit is
mismatched with the other power supply unit (in terms of
efficiency, feature set, health status, and supported voltage).
Replace the power supply unit that has the flashing indicator with a
power supply unit that matches the capacity of the other installed
power supply unit.
C Flashing amber Indicates a problem with the power supply unit.
CAUTION: When correcting a power supply unit mismatch,
replace only the power supply unit with the flashing
indicator. Swapping the opposite power supply unit to make
a matched pair can result in an error condition and
unexpected system shutdown. To change from a High
Output configuration to a Low Output configuration or vice
versa, you must power down the system.
CAUTION: AC power supplies support both 220 V and 110 V
input voltages with the exception of Titanium power
supplies, which support only 220 V. When two identical
power supplies receive different input voltages, they can
output different wattages, and trigger a mismatch.
CAUTION: If two power supplies are used, they must be of
the same type and have the same maximum output power.
CAUTION: Combining AC and DC power supplies is not
supported and triggers a mismatch.
D Not lit Power is not connected.
Documentation matrix
The documentation matrix provides information on documents that you can refer to for setting up and
managing your system.
To... Refer to...
Install your system into a rack Rack documentation included with your rack
solution
Set up your system and know the system technical
specifications
Getting Started With Your System that shipped with
your system or see dell.com/poweredgemanuals
Install the operating system Operating system documentation at dell.com/
operatingsystemmanuals
26
To... Refer to...
Get an overview of the Dell Systems Management
offerings
Dell OpenManage Systems Management Overview
Guide at dell.com/openmanagemanuals
Configure and log in to iDRAC, set up managed
and management system, know the iDRAC
features and troubleshoot using iDRAC
Integrated Dell Remote Access Controller User's
Guide at dell.com/esmmanuals
Know about the RACADM subcommands and
supported RACADM interfaces
RACADM Command Line Reference Guide for
iDRAC and CMC at dell.com/esmmanuals
Launch, enable and disable Lifecycle Controller,
know the features, use and troubleshoot Lifecycle
Controller
Dell Lifecycle Controller User’s Guide at dell.com/
esmmanuals
Use Lifecycle Controller Remote Services Dell Lifecycle Controller Remote Services Quick
Start Guide at dell.com/esmmanuals
Set up, use, and troubleshoot OpenManage Server
Administrator
Dell OpenManage Server Administrator User’s
Guide at dell.com/openmanagemanuals
Install, use and troubleshoot OpenManage
Essentials
Dell OpenManage Essentials User’s Guide at
dell.com/openmanagemanuals
Know the features of the storage controller cards,
deploy the cards, and manage the storage
subsystem
Storage controller documentation at dell.com/
storagecontrollermanuals
Check the event and error messages generated by
the system firmware and agents that monitor
system components
Dell Event and Error Messages Reference Guide at
dell.com/esmmanuals
Quick Resource Locator
Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to
videos. This can be done by visiting dell.com/QRL or by using your smartphone or tablet and a model
specific Quick Resource (QR) code located on your Dell PowerEdge system. To try out the QR code, scan
the following image.
27
2
Performing initial system configuration
After you receive your PowerEdge system, you must set up your system, install the operating system, and
set up and configure the system iDRAC IP address for system management.
Setting up your system
1. Unpack the server.
2. Install the server into the rack. For more information on installing the server into the rack, see your
system's Rack Installation Placemat at dell.com/poweredgemanuals.
3. Connect any peripherals to the system.
4. Connect the system to its electrical outlet.
5. Turn the system on by pressing the power button or using iDRAC.
6. Turn on the attached peripherals.
Methods of setting up and configuring the iDRAC IP
address
You can set up the Integrated Dell Remote Access Controller (iDRAC) IP address by using one of the
following interfaces:
1. iDRAC Settings utility.
2. Lifecycle Controller.
3. Dell Deployment Toolkit.
4. Server LCD panel.
5. Quick Sync (optional)
You can configure iDRAC IP using:
1. iDRAC Web Interface.
For more information, see the Integrated Dell Remote Access Controller User's Guide.
2. Remote Access Controller ADMin (RACADM).
For more information, see the RACADM Command Line Interface Reference Guide and the
Integrated Dell Remote Access Controller User's Guide.
3. Remote Services that includes Web Services Management (WS-Man). For more information, see the
Lifecycle Controller Remote Services Quick Start Guide.
For more information on setting up and configuring iDRAC, see the Integrated Dell Remote Access
Controller User's Guide at dell.com/esmmanuals.
28
Information about logging in to iDRAC
You can log in to iDRAC as an iDRAC local user, as a Microsoft Active Directory user, or as a Lightweight
Directory Access Protocol (LDAP) user. You can also log in using Single Sign-On or Smart Card. The
default user name is root and password is calvin. For more information on logging in to iDRAC and
iDRAC licenses, see the Integrated Dell Remote Access Controller User's Guide at dell.com/esmmanuals.
You can also access the iDRAC using RACADM. For more information, see the RACADM Command Line
Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide available at
dell.com/esmmanuals.
Methods of installing the operating system
If the server is shipped without an operating system, install the supported operating system on the server
using the following methods:
• Dell Systems Management Tools and Documentation media. See the operating system
documentation at dell.com/operatingsystemmanuals.
• Dell Lifecycle Controller. See the Lifecycle Controller documentation at dell.com/esmmanuals.
• Dell OpenManage Deployment Toolkit. See the OpenManage documentation at dell.com/
openmanagemanuals.
For information on the list of operating systems supported on your system, see the operating systems
support matrix at dell.com/ossupport.
Remote management
To perform out-of-band systems management using iDRAC, you must configure iDRAC for remote
accessibility, set up the management station and managed system, and configure the supported Web
browsers. For more information, see the Integrated Dell Remote Access Controller User’s Guide at
dell.com/esmmanuals.
You can also remotely monitor and manage the server, using the Dell OpenManage Server Administrator
(OMSA) software and OpenManage Essentials (OME) systems management console. For more
information, see dell.com/openmanagemanuals.
Downloading and installing drivers and firmware
It is recommended that you download and install the latest BIOS, drivers, and systems management
firmware on your system.
Prerequisites
NOTE: Ensure that you clear the web browser cache.
Steps
1. Go to dell.com/support/drivers.
2. In the Product Selection section, enter the service tag of your system in the Service Tag or Express
Service Code field.
29
NOTE: If you do not have the service tag, select Automatically detect my Service Tag for me to
allow the system to automatically detect your service tag, or select Choose from a list of all
Dell products to select your product from the Product Selection page.
3. Click Get drivers and downloads.
The drivers that are applicable to your selection are displayed.
4. Download the drivers that you require to a diskette drive, USB drive, CD, or DVD.
30
3
Pre-operating system management
applications
The pre-operating system management applications for your PowerEdge system help you manage
different settings and features of your system without booting to the operating system.
Your PowerEdge system has the following pre-operating system management applications:
• System Setup
• Boot Manager
• Dell Lifecycle Controller
Dell Lifecycle Controller allows you to perform useful tasks such as configuring BIOS and hardware
settings, deploying operating system, updating drivers, changing RAID settings, and saving hardware
profiles. For more information about Dell Lifecycle Controller, see the documentation at dell.com/
esmmanuals.
Navigation keys
The navigation keys can help you access the pre-operating system management applications.
Key Description
<PgUp> Moves to the previous screen.
<PgDn> Moves to the next screen.
Up arrow Moves to the previous field.
Down
arrow
Moves to the next field.
<Enter> Enables you to type a value in the selected field (if applicable) or follow the link in the field.
Spacebar Expands or collapses a drop-down list, if applicable.
<Tab> Moves to the next focus area.
NOTE: This feature is applicable for the standard graphics browser only.
<Esc> Moves to the previous page till you view the main screen. Pressing <Esc> in the main
screen exits System BIOS/IDRAC Settings/Device Settings/Service Tag Settings and
proceeds with system boot.
<F1> Displays the System Setup help text.
31
About System Setup
Using System Setup, you can configure the BIOS settings, iDRAC settings, and device settings of your
system.
You can access System Setup in two ways:
• Standard Graphical Browser— This is enabled by default.
• Text Browser— This is enabled using Console Redirection.
NOTE: By default, help text for the selected field is displayed in the graphical browser. To view the
help text in the text browser, press <F1>.
Entering System Setup
1. Turn on or restart your system.
2. Press <F2> immediately after you see the following message:
<F2> = System Setup
If your operating system begins to load before you press <F2>, allow the system to finish booting,
and then restart your system and try again.
System Setup Main Menu
Option Description
System BIOS Enables you to configure BIOS settings.
iDRAC Settings Enables you to configure iDRAC settings.
The iDRAC Settings utility is an interface to set up and configure the iDRAC
parameters using UEFI. You can enable or disable various iDRAC parameters by
using the iDRAC Settings utility. For more information about this utility, see the
Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals.
Device Settings Enables you to configure device settings.
System BIOS screen
You can use the System BIOS screen to view BIOS settings as well as edit specific functions such as boot
order, system password, setup password, setting RAID mode, and enabling or disabling USB ports.
In the System Setup Main Menu, click System BIOS.
The System BIOS screen details are explained below.
Example
Menu Item Description
System
Information
Displays information about the system such as the system model name, BIOS
version, Service Tag, and so on.
Memory Settings Displays information and options related to installed memory.
32
Menu Item Description
Processor Settings Displays information and options related to the processor such as speed, cache
size, and so on.
SATA Settings Displays options to enable or disable the integrated SATA controller and ports.
Boot Settings Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify
UEFI and BIOS boot settings.
Integrated
Devices
Displays options to enable or disable integrated device controllers and ports, and to
specify related features and options.
Serial
Communication
Displays options to enable or disable the serial ports and specify related features
and options.
System Profile
Settings
Displays options to change the processor power management settings, memory
frequency, and so on.
System Security Displays options to configure the system security settings like, system password,
setup password, TPM security, and so on. It also enables or disables support for the
power and NMI buttons on the system.
Miscellaneous
Settings
Displays options to change the system date, time, and so on.
System Information screen details
You can use the System Information screen allows to view system properties such as Service Tag, system
model, and BIOS version.
You can view the System Information screen by clicking System Setup Main Menu → System BIOS →
System Information.
The System Information screen details are explained as follows:
Example
Menu Item Description
System Model
Name
Displays the system model name.
System BIOS
Version
Displays the BIOS version installed on the system.
System
Management
Engine Version
Displays the current revision of the Management Engine firmware.
System Service
Tag
Displays the system Service Tag.
System
Manufacturer
Displays the name of the system manufacturer.
System
Manufacturer
Displays the contact information of the system manufacturer.
33
Menu Item Description
Contact
Information
System CPLD
Version
Displays the current revision of the system CPLD firmware.
UEFI Compliance
Version
Displays the system firmware UEFI compliance level.
Memory Settings screen details
You can use the Memory Settings screen to view all the memory settings as well as to enable or disable
specific memory functions such as system memory testing and node interleaving.
You can view the Memory Setting screen by clicking System Setup Main Menu → System BIOS →
Memory Settings.
The Memory Settings screen details are explained as follows:
Example
Menu Item Description
System Memory
Size
Displays the amount of memory installed in the system.
System Memory
Type
Displays the type of memory installed in the system.
System Memory
Speed
Displays the system memory speed.
System Memory
Voltage
Displays the system memory voltage.
Video Memory Displays the amount of video memory.
System Memory
Testing
Specifies whether system memory tests are run during system boot. Options are
Enabled and Disabled. By default, the System Memory Testing option is set to
Disabled.
Memory
Operating Mode
Specifies the memory operating mode. The options available are Optimizer Mode,
Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode,
and Dell Fault Resilient Mode. By default, the Memory Operating Mode option is
set to Optimizer Mode.
NOTE: The Memory Operating Mode can have different defaults and available
options based on the memory configuration of your system.
NOTE: The Dell Fault Resilient Mode establishes an area of memory that is
fault resilient. This mode can be used by an operating system that supports the
feature to load critical applications or enables the operating system kernel to
maximize system availability.
Node Interleaving Specifies if Non-Uniform Memory architecture (NUMA) is supported. If this field is
Enabled, memory interleaving is supported if a symmetric memory configuration is
34
Menu Item Description
installed. If Disabled, the system supports NUMA (asymmetric) memory
configurations. By default, Node Interleaving option is set to Disabled.
Snoop Mode Specifies the Snoop Mode options. Snoop Mode options available are Home
Snoop, Early Snoop, Cluster on Die. By default, the Snoop Mode option is set to
Early Snoop. The field is only available when Node Interleaving is Disabled.
Processor Settings screen details
You can use the Processor Settings screen to view the processor settings and perform specific functions
such as enabling virtualization technology, hardware prefetcher, and logical processor idling.
You can view the Processor Settings screen by clicking System Setup Main Menu → System BIOS →
Processor Settings.
The Processor Settings screen details are explained as follows:
Example
Menu Item Description
Logical Processor Enables or disables the logical processors and displays the number of logical
processors. If the Logical Processor option is set to Enabled, the BIOS displays all
the logical processors. If this option is set to Disabled, the BIOS only displays one
logical processor per core. By default, the Logical Processor option is set to
Enabled.
Alternate RTID
(Requestor
Transaction ID)
Setting
Enables you to allocate more RTIDs to the remote socket, thereby increasing
cache performance between the sockets or easing work in normal mode for
NUMA. By default, the Alternate RTID (Requestor Transaction ID) Setting is set to
Disabled.
Virtualization
Technology
Enables or disables the additional hardware capabilities provided for virtualization.
By default, the Virtualization Technology option is set to Enabled.
Address
Translation
Service (ATS)
Defines the Address Translation Cache (ATC) for devices to cache the DMA
transactions. This field provides an interface to a chipset's Address Translation and
Protection Table to translate DMA addresses to host addresses. By default, the
option is set to Enabled.
Adjacent Cache
Line Prefetch
Optimizes the system for applications that require high utilization of sequential
memory access. By default, the Adjacent Cache Line Prefetch option is set to
Enabled. You can disable this option for applications that require high utilization of
random memory access.
Hardware
Prefetcher
Enables or disables the hardware prefetcher. By default, the Hardware Prefetcher
option is set to Enabled.
DCU Streamer
Prefetcher
Allows you to enable or disable the Data Cache Unit (DCU) streamer prefetcher. By
default, the DCU Streamer Prefetcher option is set to Enabled.
DCU IP Prefetcher Enables or disables the Data Cache Unit (DCU) IP prefetcher. By default, the DCU
IP Prefetcher option is set to Enabled.
Execute Disable Enables or disables the execute disable memory protection technology. By default,
the Execute Disable option is set to Enabled.
35
Menu Item Description
Logical Processor
Idling
Enables or disables the operating system capability to put logical processors in the
idling state in order to reduce power consumption. By default, the option is set to
Disabled.
Configurable TDP Allows reconfiguration of Thermal Design Power (TDP) to lower levels.
TDP refers to the maximum amount of power the cooling system is required to
dissipate.
X2Apic Mode Enables or disables the X2Apic mode.
Dell Controlled
Turbo NOTE: Depending on the number of installed CPUs, there may be up to four
processor listings.
Controls the turbo engagement. Enable this option only when System Profile is set
to Performance.
Number of Cores
per Processor
Controls the number of enabled cores in each processor. By default, the Number
of Cores per Processor option is set to All.
Processor 64-bit
Support
Specifies if the processor(s) support 64-bit extensions.
Processor Core
Speed
Displays the maximum core frequency of the processor.
Processor 1 NOTE: Depending on the number of installed CPUs, there may be up to four
processor listings. The following settings are displayed for each processor
installed in the system.
Family-Model-
Stepping
Displays the family, model and stepping of the processor as defined by Intel.
Brand Displays the brand name reported by the processor.
Level 2 Cache Displays the total L2 cache.
Level 3 Cache Displays the total L3 cache.
Number of Cores Displays the number of cores per processor.
SATA Settings screen details
You can use the SATA Settings screen to view the SATA settings of SATA devices and enable RAID on
your system.
You can view the SATA Settings screen by clicking System Setup Main Menu → System BIOS → SATA
Settings.
The SATA Settings screen details are explained below.
36
Example
Menu Item Description
Embedded SATA Enables the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By
default, the Embedded SATA option is set to AHCI.
Security Freeze
Lock
Sends Security Freeze Lock command to the Embedded SATA drives during POST.
This option is only applicable to ATA and AHCI mode.
Write Cache Enables or disables the command for Embedded SATA drives during POST.
Port A Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Port B Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Port C Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Port D Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
37
Menu Item Description
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Port E Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Port F Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Port G Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Port H Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
38
Menu Item Description
Port I Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Port J Sets the drive type of the selected device. For Embedded SATA settings in ATA
mode, set this field to Auto to enable BIOS support. Set it to OFF to turn off BIOS
support.
For AHCI mode or RAID mode, BIOS always enables support.
Model Displays the drive model of the selected device.
Drive Type Displays the type of drive attached to the SATA port.
Capacity Displays the total capacity of the hard drive. The field is undefined for removable
media devices such as optical drives.
Boot Settings screen details
You can use the Boot Settings screen to set the Boot mode to either BIOS or UEFI. It also allows you to
specify the boot order.
You can view the Boot Settings screen by clicking System Setup Main Menu → System BIOS → Boot
Settings.
The Boot Settings screen details are explained as follows:
Example
Menu Item Description
Boot Mode Enables you to set the boot mode of the system.
CAUTION: Switching the boot mode may prevent the system from booting if
the operating system is not installed in the same boot mode.
NOTE: Setting this field to UEFI disables BIOS Boot Settings menu. Setting this
field to BIOS disables the UEFI Boot Settings menu.
If the operating system supports UEFI, you can set this option to UEFI. Setting this
field to BIOS allows compatibility with non-UEFI operating systems. By default, the
Boot Mode option is set to BIOS.
Boot Sequence
Retry
Enables or disables the boot sequence retry feature. If this field is enabled and the
system fails to boot, the system reattempts the boot sequence after 30 seconds. By
default, the Boot Sequence Retry option is set to Enabled.
Hard Disk Failover Specifies which devices in the Hard-Disk Drive Sequence are attempted in the
boot sequence. When the option is Disabled, only the first hard disk device in the
39
Menu Item Description
list is attempted to boot. When set to Enabled, all hard disk devices are attempted
in order, as listed in the Hard-Disk Drive Sequence. This option is not enabled for
UEFI Boot Mode.
Boot Options
Settings
Configures the boot sequence and the boot devices.
Network Settings screen details
You can use the Network Settings screen to modify PXE device settings. Network Settings are only
available in UEFI boot mode. BIOS does not control network settings in the BIOS boot mode. For BIOS
boot mode, the network settings are handled by the network controllers option ROM.
You can view the Network Settings screen by clicking System Setup Main Menu → System BIOS →
Network Settings.
The Network Settings screen details are explained as follows:
Example
Menu Item Description
PXE Device n (n =
1 to 4)
Enables or disables the device. When enabled, a UEFI boot option is created for the
device.
PXE Device n
Settings (n = 1 to
4)
Allows you to control the configuration of the PXE device.
Integrated Devices screen details
You can use the Integrated Devices screen to view and configure the settings of all integrated devices
including the video controller, integrated RAID controller, and the USB ports.
You can view the Integrated Devices screen by clicking System Setup Main Menu → System BIOS →
Integrated Devices.
The Integrated Devices screen details are explained below.
Example
Menu Item Description
USB 3.0 Setting Enables or disables the USB 3.0 support. Enable this option only if your operating
system supports USB 3.0. If you disable this option, devices operate at USB 2.0
speed. USB 3.0 is disabled by default.
User Accessible
USB Ports
Enables or disables the USB ports. Selecting Only Back Ports On disables the front
USB ports, selecting All Ports Off disables all USB ports. The USB keyboard and
mouse operates during boot process in certain operating systems. After the boot
process is complete, the USB keyboard and mouse do not work if the ports are
disabled.
NOTE: Selecting Only Back Ports On and All Ports Off will disable the USB
management port and also restrict access to iDRAC features.
Internal USB Port Enables or disables the internal USB port. By default, the option is set to Enabled.
40
Menu Item Description
Integrated RAID
Controller
Enables or disables the integrated RAID controller. By default, the option is set to
Enabled.
Integrated
Network Card 1
Enables or disables the integrated network card.
Embedded NIC1
and NIC2 NOTE: The Embedded NIC1 and NIC2 option is only available on systems that
do not have Integrated Network Card 1.
Enables or disables the Embedded NIC1 and NIC2 . If set to Disabled, the NIC may
still be available for shared network access by the embedded management
controller. The embedded NIC1 and NIC2 option is only available on systems that
do not have NDCs. This option is mutually exclusive with the Integrated Network
Card 1 option. Configure this function using the NIC management utilities of the
system.
I/OAT DMA Engine Enables or disables the I/OAT option. Enable only if the hardware and software
support the feature.
Embedded Video
Controller
Enables or disables the Embedded Video Controller. By default, the embedded
video controller is Enabled. Current state of Embedded Video Controller is
Enabled. Current State of Embedded Video Controller is a read only field,
indicating the current state for the Embedded Video Controller. If the Embedded
Video Controller is the only display capability in the system (that is, no add-in
graphics card is installed), then the Embedded Video Controller is automatically
used as the primary display even if the Embedded Video Controller setting is
Disabled.
Current State of
Embedded Video
Controller
Displays the current state of the Embedded Video Controller. Current State of
Embedded Video Controller is a read only field, indicating the current state for the
Embedded Video Controller
SR-IOV Global
Enable
Enables or disables the BIOS configuration of Single Root I/O Virtualization (SR-
IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.
OS Watchdog
Timer
If your system stops responding, this watchdog timer aids in the recovery of your
operating system. When this field is set to Enabled, the operating system is allowed
to initialize the timer. When the option is set to Disabled (the default), the timer will
have no effect on the system.
Memory Mapped
I/O above 4GB
Enables or disables the support for PCIe devices that require large amounts of
memory. By default, the option is set to Enabled.
Slot Disablement Enables or disables the available PCIe slots on your system. The Slot Disablement
feature controls the configuration of PCIe cards installed in the specified slot. Slot
disablement must be used only when the installed peripheral card is preventing
booting into the operating system or causing delays in system startup. If the slot is
disabled, both the Option ROM and UEFI driver are disabled.
41
Serial Communication screen details
You can use the Serial Communication screen to view the properties of the serial communication port.
You can view the Serial Communication screen by clicking System Setup Main Menu → System BIOS →
Serial Communication.
The Serial Communication screen details are explained below.
Example
Menu Item Description
Serial
Communication
Selects serial communication devices (Serial Device 1 and Serial Device 2) in the
BIOS. BIOS console redirection can also be enabled and the port address can be
specified. By default, Serial Communication option is set to Auto.
Serial Port
Address
Enables you to set the port address for serial devices. By default, the Serial Port
Address option is set to Serial Device 1=COM2, Serial Device 2=COM1.
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use
console redirection by SOL, configure the same port address for console
redirection and the serial device.
External Serial
Connector
Enables you to associate the external serial connector to serial device 1, serial
device 2, or remote access device. By default, the External Serial Connector option
is set to Serial Device1.
NOTE: Only Serial Device 2 can be used for SOL. To use console redirection
by SOL, configure the same port address for console redirection and the serial
device.
Failsafe Baud Rate Displays the failsafe baud rate for console redirection. The BIOS attempts to
determine the baud rate automatically. This failsafe baud rate is used only if the
attempt fails and the value must not be changed. By default, the Failsafe Baud Rate
option is set to 115200.
Remote Terminal
Type
Sets the remote console terminal type. By default, the Remote Terminal Type
option is set to VT 100/VT 220.
Redirection After
Boot
Enables or disables the BIOS console redirection when the operating system is
loaded. By default, the Redirection After Boot option is set to Enabled.
System Profile Settings screen details
You can use the System Profile Settings screen to enable specific system performance settings such as
power management.
You can view the System Profile Settings screen by clicking System Setup Main Menu → System BIOS →
System Profile Settings.
The System Profile Settings screen details are explained as follows:
42
Example
Menu Item Description
System Profile Sets the system profile. If you set the System Profile option to a mode other than
Custom, the BIOS automatically sets the rest of the options. You can only change
the rest of the options if the mode is set to Custom. By default, the System Profile
option is set to Performance Per Watt Optimized (DAPC). DAPC is Dell Active
Power Controller.
NOTE: The following parameters are available only when the System Profile is
set to Custom.
CPU Power
Management
Sets the CPU power management. By default, the CPU Power Management option
is set to System DBPM (DAPC). DBPM is Demand-Based Power Management.
Memory
Frequency
Sets the speed of the system memory. You can select Maximum Performance,
Maximum Reliability, or a specific speed.
Turbo Boost Enables or disables the processor to operate in turbo boost mode. By default, the
Turbo Boost option is set to Enabled.
Energy Efficient
Turbo
Enables or disables the Energy Efficient Turbo.
Energy Efficient Turbo (EET) is a mode of operation where a processor’s core
frequency is adjusted within the turbo range based on workload.
C1E Enables or disables the processor to switch to a minimum performance state when
it is idle. By default, the C1E option is set to Enabled.
C States Enables or disables the processor to operate in all available power states. By
default, the C States option is set to Enabled.
Collaborative CPU
Performance
Control
Enables or disables the CPU power management. When set to Enabled, the CPU
power management is controlled by the OS DBPM and the System DBPM (DAPC).
By default, the option is set to Disabled.
Memory Patrol
Scrub
Sets the memory patrol scrub frequency. By default, the Memory Patrol Scrub
option is set to Standard.
Memory Refresh
Rate
Sets the memory refresh rate to either 1x or 2x. By default, the Memory Refresh
Rate option is set to 1x.
Uncore Frequency Selects the Processor Uncore Frequency.
Dynamic mode allows the processor to optimize power resources across the cores
and uncore during runtime. The optimization of the uncore frequency to either
save power or optimize performance is influenced by the setting of the Energy
Efficiency Policy.
Energy Efficient
Policy
Selects the Energy Efficient Policy.
The CPU uses the setting to manipulate the internal behavior of the processor and
determines whether to target higher performance or better power savings.
43
Menu Item Description
Number of Turbo
Boot Enabled
Cores for
Processor 1
NOTE: If there are two processors installed in the system, you see an entry for
Number of Turbo Boost Enabled Cores for Processor 2.
Controls the number of turbo boost enabled cores for processor 1. By default, the
maximum number of cores is enabled.
Monitor/Mwait Enables the Monitor/Mwait instructions in the processor. By default, the Monitor/
Mwait option is set to Enabled for all system profiles, except Custom.
NOTE: This option can be disabled only if the C States option in Custom
mode is disabled.
NOTE: When C States is enabled in Custom mode, changing the Monitor/
Mwait setting does not impact system power/performance.
System Security settings screen details
You can use the System Security screen to perform specific functions such as setting the system
password, setup password, and disabling the power button.
You can view the System Security screen by clicking System Setup Main Menu → System BIOS →
System Security Settings.
The System Security Settings screen details are explained as follows:
Example
Menu Item Description
Intel AES-NI Improves the speed of applications by performing encryption and decryption using
the Advanced Encryption Standard Instruction Set and is set to Enabled by default.
System Password Sets the system password. This option is set to Enabled by default and is read-only
if the password jumper is not installed in the system.
Setup Password Sets the setup password. This option is read-only if the password jumper is not
installed in the system.
Password Status Locks the system password. By default, the Password Status option is set to
Unlocked.
TPM Security NOTE: The TPM menu is available only when the TPM module is installed.
Allows you to control the reporting mode of the Trusted Platform Module (TPM).
By default, the TPM Security option is set to Off. You can only modify the TPM
Status, TPM Activation , and Intel TXT fields if the TPM Status field is set to either
On with Pre-boot Measurements or On without Pre-boot Measurements.
TPM Information Changes the operational state of the TPM. By default, the TPM Activation option is
set to No Change.
TPM Status Displays the TPM status.
TPM Command CAUTION: Clearing the TPM results in the loss of all keys in the TPM. The
loss of TPM keys may affect booting to the operating system.
44
Menu Item Description
Clears all the contents of the TPM. By default, the TPM Clear option is set to No.
Intel TXT Enables or disables the Intel Trusted Execution Technology (TXT). To enable Intel
TXT, Virtualization Technology must be enabled and TPM Security must be
Enabled with Pre-boot measurements. By default, the Intel TXT option is set to
Off.
Power Button Enables or disables the power button on the front of the system. By default, the
Power Button option is set to Enabled.
NMI Button Enables or disables the NMI button on the front of the system. By default, the NMI
Button option is set to Disabled.
AC Power
Recovery
Sets how the system reacts after AC power is restored to the system. By default,
the AC Power Recovery option is set to Last.
AC Power
Recovery Delay
Sets how the system supports staggering of power up after AC power is restored to
the system. By default, the AC Power Recovery Delay option is set to Immediate.
User Defined Delay
(60s to 240s)
Sets the User Defined Delay when the User Defined option for AC Power Recovery
Delay is selected.
UEFI Variable
Access
Provides varying degrees of securing UEFI variables. When set to Standard (the
default) UEFI variables are accessible in the Operating System per the UEFI
specification. When set to Controlled, selected UEFI variables are protected in the
environment and new UEFI boot entries are forced to be at the end of the current
boot order.
Secure Boot Enables Secure Boot, where the BIOS authenticates each pre-boot image using the
certificates in the Secure Boot Policy. Secure Boot is disabled by default.
Secure Boot Policy When Secure Boot policy is Standard, the BIOS uses the system manufacturer’s key
and certificates to authenticate pre-boot images. When Secure Boot policy is
Custom, the BIOS uses the user-defined key and certificates. Secure Boot policy is
Standard by default.
Secure Boot Policy
Summary
Views the list of certificates and hashes that secure boot uses to authenticated
images.
Secure Boot Custom Policy Settings
Secure Boot Custom Policy Settings is displayed only when Secure Boot Policy is set to Custom.
In the System Setup Main Menu, click System BIOS → System Security → Secure Boot Custom Policy
Settings.
The Secure Boot Custom Policy Settings screen details are explained as follows:
Example
Menu Item Description
Platform Key Imports, exports, deletes, or restores the platform key (PK).
Key Exchange Key
Database
Allows you to import, export, delete, or restore entries in the Key Exchange Key
(KEK) Database
45
Menu Item Description
Authorized
Signature
Database
Imports, exports, deletes, or restores entries in the Authorized Signature Database
(db).
Forbidden
Signature
Database
Imports, exports, deletes, or restores entries in the Forbidden Signature Database
(dbx).
Miscellaneous Settings screen details
You can use the Miscellaneous Settings screen to perform specific functions such as updating the asset
tag, and changing the system date and time.
You can view the Miscellaneous Settings screen by clicking System Setup Main Menu → System BIOS →
Miscellaneous Settings.
The Miscellaneous Settings screen details are explained as follows:
Example
Menu Item Description
System Time Enables you to set the time on the system.
System Date Enables you to set the date on the system.
Asset Tag Displays the asset tag and enables you to modify it for security and tracking
purposes.
Keyboard
NumLock
Enables you to set whether the system boots with the NumLock enabled or
disabled. By default the Keyboard NumLock is set to On.
NOTE: This option does not apply to 84-key keyboards.
F1/F2 Prompt on
Error
Enables or disables the F1/F2 prompt on error. By default, F1/F2 Prompt on Error is
set to Enabled. The F1/F2 prompt also includes keyboard errors.
Load Legacy
Video Option
ROM
Enables you to determine whether the system BIOS loads the legacy video (INT
10H) option ROM from the video controller. Selecting Enabled in the operating
system does not support UEFI video output standards. This field is only for UEFI
boot mode. You cannot set this to Enabled if UEFI Secure Boot mode is enabled.
In-System
Characterization
This option enables or disables In-System Characterization. By default, In-System
Characterization is set to Disabled. The two other options are Enabled and
Enabled - No Reboot.
NOTE: The default setting for In-System Characterization is subject to change
in future BIOS releases.
When enabled, In-System Characterization (ISC) executes during POST upon
detecting relevant change(s) in system configuration to optimize system power and
performance. ISC takes about 20 seconds to execute, and system reset is required
for ISC results to be applied. The Enabled - No Reboot option executes ISC and
continues without applying ISC results until the next time system reset occurs. The
Enabled option executes ISC and forces an immediate system reset so that ISC
46
Menu Item Description
results can be applied. It takes the system longer to be ready due to the forced
system reset. When disabled, ISC does not execute.
About Boot Manager
Boot Manager enables you to add, delete, and arrange boot options. You can also access System Setup
and boot options without restarting the system.
Entering Boot Manager
The Boot Manager screen allows you to select boot options and diagnostic utilities.
1. Turn on or restart your system.
2. Press <F11> when you see the message <F11> = Boot Manager.
If your operating system begins to load before you press <F11>, allow the system to finish booting,
and then restart your system and try again.
Boot Manager main menu
Menu Item Description
Continue Normal
Boot
The system attempts to boot to devices starting with the first item in the boot
order. If the boot attempt fails, the system continues with the next item in the boot
order until the boot is successful or no more boot options are found.
One Shot Boot
Menu
Takes you to the boot menu where you can select a one time boot device to boot
from.
Launch System
Setup
Enables you to access the System Setup.
Launch Lifecycle
Controller
Exits the Boot Manager and invokes the Lifecycle Controller program.
System Utilities Launches system utilities menu such as system diagnostics and UEFI shell.
Changing the boot order
You may have to change the boot order if you want to boot from a USB key or an optical drive.
About this task
NOTE: The instructions given below may vary if you have selected BIOS for Boot Mode.
Steps
1. In the System Setup Main Menu, click System BIOS → Boot Settings.
2. Click Boot Option Settings → Boot Sequence.
3. Use the arrow keys to select a boot device, and use the + and - keys to move the device down or up
in the ordering.
4. Click Exit, click Yes to save the settings on exit.
47
Choosing the system boot mode
System Setup enables you to specify the boot mode for installing your operating system:
• BIOS boot mode (the default) is the standard BIOS-level boot interface.
• UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface
(UEFI) specifications that overlays the system BIOS.
You must select the boot mode in the Boot Mode field of the Boot Settings screen of System Setup.
Once you specify the boot mode, the system boots in the specified boot mode and you then proceed to
install your operating system from that mode. Thereafter, you must boot the system in the same boot
mode (BIOS or UEFI) to access the installed operating system. Trying to boot the operating system from
the other boot mode will cause the system to halt at startup.
NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS
and 32-bit operating systems do not support UEFI and can only be installed from the BIOS boot
mode.
NOTE: For the latest information on supported operating systems, go to dell.com/ossupport.
Assigning a system and setup password
Prerequisites
NOTE: The password jumper enables or disables the System Password and Setup Password
features. For more information about the password jumper settings, see System Board Connectors.
You can assign a new System Password and Setup Password or change an existing System Password
and Setup Password only when the password jumper setting is enabled and Password Status is
Unlocked.
If the password jumper setting is disabled, the existing System Password and Setup Password are deleted
and you need not provide the system password to boot the system.
About this task
To assign a System Password and Setup Password, follow the steps below:
Steps
1. To enter System Setup, press <F2> immediately after a power-on or reboot.
2. From the System Setup Main Menu, select System BIOS and press <Enter>.
The System BIOS screen is displayed.
3. On the System BIOS screen, select System Security and press <Enter>.
The System Security screen is displayed.
4. On the System Security screen, verify that Password Status is Unlocked.
5. Select System Password, enter your system password, and press <Enter> or <Tab>.
Use the following guidelines to assign the system password:
• A password can have up to 32 characters.
• The password can contain the numbers 0 through 9.
• Only the following special characters are allowed: space, (”), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`).
A message prompts you to re-enter the system password.
48
6. Re-enter the system password, and click OK.
7. Select Setup Password, enter your system password and press <Enter> or <Tab>.
A message prompts you to re-enter the setup password.
8. Re-enter the setup password, and click OK.
9. Press <Esc> to return to the System BIOS screen. Press <Esc> again.
A message prompts you to save the changes.
NOTE: Password protection does not take effect until the system reboots.
Deleting or changing an existing system password and
setup password
Prerequisites
Ensure that the Password jumper is set to enabled and the Password Status is Unlocked before
attempting to delete or change the existing System and/or Setup password. You cannot delete or change
an existing System or Setup password if the Password Status is Locked.
Steps
1. To enter System Setup, press <F2> immediately after a power on or restart.
2. From the System Setup Main Menu, select System BIOS and press <Enter>.
The System BIOS screen is displayed.
3. On the System BIOS Screen, select System Security and press <Enter>.
The System Security screen is displayed.
4. On the System Security screen, verify that Password Status is Unlocked.
5. Select System Password, alter or delete the existing system password and press <Enter> or <Tab>.
6. Select Setup Password, alter or delete the existing setup password and press <Enter> or <Tab>.
If you change the System and Setup password a message prompts you to re-enter the new
password. If you delete the System and Setup password, a message prompts you to confirm the
deletion.
7. Press <Esc> to return to the System BIOS screen. Press <Esc> again, and a message prompts you to
save the changes.
49
4
Installing and removing system
components
Safety instructions
WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not
attempt to lift the system by yourself.
WARNING: Opening or removing the system cover when the system is on may expose you to a
risk of electric shock.
CAUTION: Do not operate the system without the cover for a duration exceeding five minutes.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: It is recommended that you always use a static mat and static strap while working on
components inside the system.
NOTE: To ensure proper operation and cooling, all bays in the system must be populated at all
times with either a module or with a blank.
Before working inside your system
1. Turn off the system, including any attached peripherals.
2. Disconnect the system from the electrical outlet and disconnect the peripherals.
3. If installed, remove the front bezel.
For more information, see Removing the front bezel.
4. Remove the system cover.
For more information, see Removing the system cover.
After working inside your system
1. Install the system cover.
For more information, see Installing the system cover.
2. Install the optional bezel.
3. Reconnect the system to its electrical outlet and peripherals.
4. Turn the system on, including any attached peripherals.
50
Recommended tools
You need the following tools to perform the removal and installation procedures:
• Key to the bezel lock. This is only required when you have a bezel.
• #2 Phillips screwdriver
• #1 Phillips screwdriver
• T6, T8, T10, and T15 Torx screwdrivers
The following tools are required for assembling cables for a DC power supply unit (PSU):
• AMP 90871-1 hand-crimping tool or equivalent
• Tyco Electronics 58433-3 or equivalent
• Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated
copper wire
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding).
Front bezel (optional)
Removing the front bezel
1. Unlock the bezel lock at the left end of the bezel.
2. Lift the release latch next to the bezel lock.
3. Pull the left end of the bezel, unhook the right end and remove the bezel.
51
Figure 13. Removing and installing the front bezel
Installing the front bezel
1. Hook the right end of the bezel onto the chassis.
2. Fit the free end of the bezel onto the system.
3. Secure the bezel with the keylock.
Removing the system cover
Prerequisites
1. Ensure that you read the Safety instructions.
2. Turn off the system, including any attached peripherals.
3. Disconnect the system from the electrical outlet and peripherals.
4. Remove the optional bezel. For more information, see Removing the front bezel.
Steps
1. Turn the latch release lock to the unlock position.
2. Lift the cover release latch and remove the system cover.
52
Figure 14. Removing and installing the system
1. latch release lock 2. system cover
3. latch
Installing the system cover
Prerequisites
Ensure that you read the Safety instructions.
Steps
1. Align the slots of the system cover with the tabs on the chassis.
2. Press the cover release latch, and push the cover toward the front of the chassis until the latch locks
into place.
3. Turn the latch release lock clockwise to the locked position.
4. Install the optional bezel.
5. Reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
53
Inside the system
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: Components that are hot-swappable are marked orange and touch points on the
components are marked blue.
Figure 15. Inside the system—8 hard-drive system
1. control panel assembly 2. cooling fans (7)
3. processor 1 4. DIMMs (6)
5. PSU connector 6. power supply (2)
7. riser card 3 8. network daughter card
54
9. riser card 2 10. riser card 1
11. DIMMs (6) 12. processor 2
13. DIMMs (12) 14. hard-drive backplane
15. hard drive
Figure 16. Inside the system—24 hard-drive system and 10 hard-drive system
1. control panel assembly 2. cooling fans (7)
3. processor 1 4. DIMMs (6)
5. PSU connector 6. power supply (2)
7. riser card 3 8. network daughter card
9. riser card 1 10. riser card 2
11. DIMMs (6) 12. processor 2
13. DIMMs (12) 14. expander board
55
15. hard drive
Cooling shroud
Removing the cooling shroud
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: Never operate your system with the cooling shroud removed. The system may get
overheated quickly, resulting in shutdown of the system and loss of data.
Steps
Hold the touch points and lift the shroud away from the system.
Figure 17. Removing and installing the cooling shroud
1. cooling shroud
Next steps
1. Replace the cooling shroud.
2. Follow the procedure listed in After working inside your system.
56
Installing the cooling shroud
Prerequisites
• Ensure that you read the Safety instructions.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: For proper seating of the cooling shroud in the chassis, ensure that the cables inside the
system are routed along the chassis wall and secured using the cable securing bracket.
Steps
1. Align the tabs on the cooling shroud with the securing slots on the chassis.
2. Lower the cooling shroud into the chassis until it is firmly seated.
Next steps
Follow the procedure listed in After working inside your system.
System memory
Your system supports DDR4 registered DIMMs (RDIMMs), and load reduced DIMMs (LRDIMMs).
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
Memory bus operating frequency can be 1333 MT/s, 1600 MT/s, 1866 MT/s, or 2133 MT/s depending on
the following factors:
• DIMM type (RDIMM or LRDIMM)
• Number of DIMMs populated per channel
• System profile selected (for example, Performance Optimized, Custom, or Dense Configuration
Optimized)
• Maximum supported DIMM frequency of the processors
The system contains 24 memory sockets split into two sets of 12 sockets, one set per processor. Each 12-
socket set is organized into four channels. In each channel, the release levers of the first socket are
marked white, the second socket black, and the third socket green.
NOTE: DIMMs in sockets A1 to A12 are assigned to processor 1 and DIMMs in sockets B1 to B12 are
assigned to processor 2.
57
Figure 18. Memory socket locations
Memory channels are organized as follows:
Processor 1 channel 0: slots A1, A5, and A9
channel 1: slots A2, A6, and A10
channel 2: slots A3, A7, and A11
channel 3: slots A4, A8, and A12
Processor 2 channel 0: slots B1, B5, and B9
channel 1: slots B2, B6, and B10
channel 2: slots B3, B7, and B11
58
channel 3: slots B4, B8, and B12
The following table shows the memory populations and operating frequencies for the supported
configurations.
DIMM Type DIMMs Populated/
Channel Operating Frequency (in
MT/s) Maximum DIMM Rank/Channel
1.2 V
RDIMM 1 2133, 1866, 1600, 1333 Dual rank or single rank
2 2133, 1866, 1600, 1333 Dual rank or single rank
3 1866, 1600, 1333 Dual rank or single rank
LRDIMM 1 2133, 1866, 1600, 1333 Quad rank
2 2133, 1866, 1600, 1333 Quad rank
3 1866, 1600, 1333 Quad rank
General memory module installation guidelines
This system supports Flexible Memory Configuration, enabling the system to be configured and run in
any valid chipset architectural configuration. The following are the recommended guidelines for installing
memory modules:
• RDIMMs and LRDIMMs must not be mixed.
• x4 and x8 DRAM based DIMMs can be mixed. For more information, see Mode-specific guidelines.
• Up to three dual- or single-rank RDIMMs can be populated per channel.
• Up to three LRDIMMs can be populated per channel regardless of rank count.
• Populate DIMM sockets only if a processor is installed. For single-processor systems, sockets A1 to
A12 are available. For dual-processor systems, sockets A1 to A12 and sockets B1 to B12 are available.
• Populate all sockets with white release tabs first, then black, and then green.
• Populate the sockets by highest rank count in the following order — first in sockets with white release
levers, then black, and then green. For example, if you want to mix single-rank and dual-rank DIMMs,
populate dual-rank DIMMs in the sockets with white release tabs and single-rank DIMMs in the
sockets with black release tabs.
• When mixing memory modules with different capacities, populate the sockets with memory modules
with highest capacity first. For example, if you want to mix 4 GB and 8 GB DIMMs, populate 8 GB
DIMMs in the sockets with white release tabs and 4 GB DIMMs in the sockets with black release tabs.
• In a dual-processor configuration, the memory configuration for each processor should be identical.
For example, if you populate socket A1 for processor 1, then populate socket B1 for processor 2, and
so on.
• Memory modules of different capacities can be mixed provided other memory population rules are
followed (for example, 4 GB and 8 GB memory modules can be mixed).
• Mixing of more than two DIMM capacities in a system is not supported.
• Populate four DIMMs per processor (one DIMM per channel) at a time to maximize performance.
Mode-specific guidelines
Four memory channels are allocated to each processor. The allowable configurations depend on the
memory mode selected.
59
NOTE: You can mix x4 and x8 DRAM based DIMMs to support RAS features. However, all guidelines
for specific RAS features must be followed. x4 DRAM based DIMMs retain Single Device Data
Correction (SDDC) in memory optimized (independent channel) mode. x8 DRAM based DIMMs
require Advanced ECC mode to gain SDDC.
The following sections provide additional slot population guidelines for each mode:
Advanced ECC (lockstep)
Advanced ECC mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This
protects against single DRAM chip failures during normal operation.
Memory installation guidelines:
• Memory modules must be identical in size, speed, and technology.
• DIMMs installed in memory sockets with white release tabs must be identical and similar rule applies
for sockets with black and green release tabs. This ensures that identical DIMMs are installed in
matched pairs - for example, A1 with A2, A3 with A4, A5 with A6, and so on.
NOTE: Advanced ECC with Mirroring is not supported.
Memory optimized (independent channel) mode
This mode supports SDDC only for memory modules that use x4 device width, and the mode does not
impose any specific slot population requirements.
Memory sparing
NOTE: To use memory sparing, this feature must be enabled in the System Setup.
In this mode, one rank per channel is reserved as a spare. If persistent correctable errors are detected on
a rank, the data from this rank is copied to the spare rank and the failed rank is disabled.
With memory sparing enabled, the system memory available to the operating system is reduced by one
rank per channel. For example, in a dual-processor configuration with sixteen 4 GB dual-rank DIMMs, the
available system memory is: 3/4 (ranks/channel) × 16 (DIMMs) × 4 GB = 48 GB, and not 16 (DIMMs) × 4
GB = 64 GB.
NOTE: Memory sparing does not offer protection against a multi-bit uncorrectable error.
NOTE: Both Advanced ECC/Lockstep and Optimizer modes support Memory Sparing.
Memory mirroring
Memory Mirroring offers the strongest DIMM reliability mode compared to all other modes, providing
improved uncorrectable multi-bit failure protection. In a mirrored configuration, the total available
system memory is one half of the total installed physical memory. Half of the installed memory is used to
mirror the active DIMMs. In the event of an uncorrectable error, the system switches over to the mirrored
copy. This ensures SDDC and multi-bit protection.
Memory installation guidelines:
• Memory modules must be identical in size, speed, and technology.
• DIMMs installed in memory sockets with white release levers must be identical and similar rule applies
for sockets with black and green release tabs. This ensures that identical DIMMs are installed in
matched pairs - for example, A1 with A2, A3 with A4, A5 with A6, and so on.
60
Sample memory configurations
The following tables show sample memory configurations for one and two processor configurations that
follow the appropriate memory guidelines.
NOTE: 1R, 2R, and 4R in the following tables indicate single-, dual-, and quad-rank DIMMs
respectively.
Table 1. Memory configurations—single processor
System
capacity (in
GB)
DIMM size
(in GB) Number of
DIMMs DIMM rank,
organization, and
frequency
DIMM slot population
4 4 1 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1
8 4 2 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2
16 4 4 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2, A3, A4
8 2 2R, x8, 2133 MT/s,
2R, x8, 1866 MT/s
A1, A2
24 4 6 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6
48 4 12 1R, x8, 1866 MT/s
1R, x8, 1600 MT/s
A1, A2, A3, A4, A5, A6, A7, A8, A9,
A10, A11, A12
8 6 2R, x8, 2133 MT/s,
2R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6
96 8 12 2R, x8, 1866 MT/s
2R, x8 1600 MT/s
A1, A2, A3, A4, A5, A6, A7, A8, A9,
A10, A11, A12
16 6 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s
A1, A2, A3, A4, A5, A6
128 16 8 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s,
A1, A2, A3, A4, A5, A6, A7, A8
144 16 and 8 10 2R, x4 and 2R, x8, 1866
MT/s
A1, A2, A3, A4, A5, A6, A7, A8, A9,
A11
61
System
capacity (in
GB)
DIMM size
(in GB) Number of
DIMMs DIMM rank,
organization, and
frequency
DIMM slot population
2R, x4 and 2R, x8, 1600
MT/s NOTE: 16 GB DIMMs must
be installed in slots
numbered A1, A2, A3, A4, A5,
A6, A7, and A8 and 8 GB
DIMMs must be installed in
slots A9 and A11.
384 32 12 LRDIMM, x4, 1866 MT/s
LRDIMM, x4, 1600 MT/s
A1, A2, A3, A4, A5, A6, A7, A8, A9,
A10, A11, A12
Table 2. Memory configurations—two processors
System
capacity (in
GB)
DIMM size (in
GB) Number of
DIMMs DIMM rank,
organization, and
frequency
DIMM slot population
16 4 4 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2, B1, B2
32 4 8 1R, x8, 2133 MT/s,
1R, x8, 1866 MT/s
A1, A2, A3, A4, B1, B2, B3, B4
64 4 16 1R, x8, 2133 MT/s
1R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6, A7, A8,
B1, B2, B3, B4, B5, B6, B7, B8
8 8 2R, x8, 2133 MT/s,
2R, x8, 1866 MT/s
A1, A2, A3, A4, B1, B2, B3, B4
96 4 24 1R, x8, 1866 MT/s
1R, x8, 1600 MT/s
A1, A2, A3, A4, A5, A6, A7, A8,
A9, A10, A11, A12, B1, B2, B3, B4,
B5, B6, B7, B8, B9, B10, B11, B12
8 12 2R, x8, 2133 MT/s,
2R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6, B1, B2,
B3, B4, B5, B6
128 8 16 2R, x8, 2133 MT/s
2R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6, A7, A8,
B1, B2, B3, B4, B5, B6, B7, B8
16 8 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s
A1, A2, A3, A4, B1, B2, B3, B4
62
System
capacity (in
GB)
DIMM size (in
GB) Number of
DIMMs DIMM rank,
organization, and
frequency
DIMM slot population
160 8 20 2R, x8, 1866 MT/s
2R, x8, 1600 MT/s
A1, A2, A3, A4, A5, A6, A7, A8,
A9, A11, B1, B2, B3, B4, B5, B6,
B7, B8, B9, B11
16 and 8 12 2R, x4, 2133 MT/s,
2R, x8, 2133 MT/s,
2R, x4, 1866 MT/s
2R, x8, 1866 MT/s
A1, A2, A3, A4, A5, A6, B1, B2,
B3, B4, B5, B6
NOTE: 16 GB DIMMs must
be installed in slots
numbered A1, A2, A3, A4,
B1, B2, B3, and B4 and 8
GB DIMMs must be
installed in slots A5, A6, B5,
and B6.
192 8 24 2R, x8, 1866 MT/s
2R, x8, 1600 MT/s
A1, A2, A3, A4, A5, A6, A7, A8,
A9, A10, A11, A12, B1, B2, B3, B4,
B5, B6, B7, B8, B9, B10, B11, B12
16 12 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s
A1, A2, A3, A4, A5, A6, B1, B2,
B3, B4, B5, B6
256 16 16 2R, x4, 2133 MT/s,
2R, x4, 1866 MT/s,
A1, A2, A3, A4, A5, A6, A7, A8,
B1, B2, B3, B4, B5, B6, B7, B8
384 16 24 2R, x4, 1866 MT/s,
2R, x4, 1600 MT/s,
A1, A2, A3, A4, A5, A6, A7, A8,
A9, A10, A11, A12, B1, B2, B3, B4,
B5, B6, B7, B8, B9, B10, B11, B12
32 12 LRDIMM, 4R, x4, 2133
MT/s
A1, A2, A3, A4, A5, A6, B1, B2,
B3, B4, B5, B6
512 32 16 LRDIMM, 4R, x4, 2133
MT/s
A1, A2, A3, A4, A5, A6, A7, A8,
B1, B2, B3, B4, B5, B6, B7, B8
768 32 24 LRDIMM, 4R, x4, 1866
MT/s
LRDIMM, 4R, x4, 1600
MT/s
A1, A2, A3, A4, A5, A6, A7, A8,
A9, A10, A11, A12, B1, B2, B3, B4,
B5, B6, B7, B8, B9, B10, B11, B12
Removing memory modules
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
63
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
WARNING: The memory modules are hot to the touch for some time after the system has been
powered down. Allow time for the memory modules to cool before handling them. Handle the
memory modules by the card edges and avoid touching the components or metallic contacts on
the memory module.
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any
memory socket that is not occupied. Remove memory-module blanks only if you intend to install
memory modules in those sockets.
Steps
1. Locate the appropriate memory module socket.
CAUTION: Handle each memory module only by the card edges, making sure not to touch
the middle of the memory module or gold contacts.
2. To release the memory module from the socket, simultaneously press the ejectors on both ends of
the memory-module socket.
Figure 19. Removing and installing a memory module
1. memory-module 2. memory-module socket
3. memory module socket ejector (2)
64
Installing memory modules
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
4. Removing the cooling-fan assembly.
WARNING: The memory modules are hot to the touch for some time after the system has been
powered down. Allow time for the memory modules to cool before handling them. Handle the
memory modules by the card edges and avoid touching the components or metallic contacts on
the memory module.
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any
memory socket that is not occupied. Remove memory-module blanks only if you intend to install
memory modules in those sockets.
Steps
1. Locate the appropriate memory-module socket.
CAUTION: Handle each memory module only by the card edges, making sure not to touch
the middle of the memory module or gold contacts.
2. If a memory module or a memory-module blank is installed in the socket, remove it.
NOTE: Retain the removed memory-module blank(s) for future use.
CAUTION: To prevent damage to the memory module or the memory-module socket during
installation, do not bend or flex the memory module; insert both ends of the memory module
simultaneously.
3. Align the edge connector of the memory module with the alignment key of the memory module
socket, and insert the memory module in the socket.
NOTE: The memory-module socket has an alignment key that allows you to install the memory
module in the socket in only one orientation.
CAUTION: Do not apply pressure at the center of the memory module; apply pressure at both
ends of the memory module evenly.
4. Press the memory module with your thumbs until the socket levers firmly click into place.
65
Figure 20. Installing the memory module
1. memory module 2. alignment key
3. memory-module socket ejector (2)
When the memory module is properly seated in the socket, the levers on the memory module socket
align with the levers on the other sockets that have memory modules installed.
5. Repeat steps 4 and 5 of this procedure to install the remaining memory modules.
Next steps
1. Install the cooling shroud.
2. Follow the procedure listed in After working inside your system.
3. Press <F2> to enter System Setup, and check the System Memory setting.
The system should have already changed the value to reflect the installed memory.
4. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat
step 4 through step 7 of this procedure, checking to ensure that the memory modules are firmly
seated in their sockets.
5. Run the system memory test in the system diagnostics.
Hard drives
All hard drives connect to the system board through the hard-drive backplane. Hard drives are supplied in
hot-swappable hard-drive carriers that fit in the hard-drive slots.
CAUTION: Before attempting to remove or install a hard drive while the system is running, see the
documentation for the storage controller card to ensure that the host adapter is configured
correctly to support hot-swap hard drive removal and insertion.
CAUTION: Do not turn off or reboot your system while the hard drive is being formatted. Doing
so can cause a hard drive failure.
66
NOTE: Use only hard drives that have been tested and approved for use with the hard-drive
backplane.
When you format a hard drive, allow enough time for the formatting to be completed. Be aware that
high-capacity hard drives can take a number of hours to format.
Removing a 2.5 inch hard-drive blank
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive
blanks installed.
1. Ensure that you read the Safety instructions.
2. If installed, remove the bezel.
Steps
Press the release button and slide the hard-drive blank out of the hard-drive slot.
Figure 21. Removing and installing a 2.5 inch hard-drive blank
1. hard-drive blank 2. release button
Installing a 2.5 inch hard-drive blank
Prerequisites
1. Ensure that you read the Safety instructions.
2. If installed, remove the front bezel.
67
Steps
Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.
Next steps
If applicable, install the front bezel.
Removing a 1.8 inch hard-drive blank
Prerequisites
1. Ensure that you read the Safety instructions.
2. If installed, remove the front bezel.
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive
blanks installed.
Steps
Press the release button and slide the hard-drive blank out of the hard-drive slot.
Figure 22. Removing and installing a 1.8 inch hard-drive blank
1. hard-drive blank 2. release button
Next steps
If applicable, install the front bezel.
Installing a 1.8 inch hard-drive blank
Prerequisites
1. Ensure that you read the Safety instructions.
2. If installed, remove the front bezel.
68
Steps
Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.
Next steps
If applicable, install the front bezel.
Removing a hot-swap hard drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. If applicable, remove the bezel.
3. Using the management software, prepare the hard drive for removal. Wait until the indicators on the
hard-drive carrier signal that the hard drive can be removed safely. For more information, see the
documentation for the storage controller.
If the hard drive is online, the green activity/fault indicator flashes as the drive is turned off. When the
hard-drive indicators are off, the hard drive is ready for removal.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive
installation. See the documentation supplied with your operating system.
Steps
1. Press the release button to open the hard-drive carrier release handle.
2. Slide the hard-drive carrier out of the hard-drive slot.
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-
drive blanks installed.
3. If you are not replacing the hard drive immediately, insert a hard-drive blank in the empty hard-drive
slot.
69
Figure 23. Removing and installing a hot-swap hard drive
1. release button 2. hard-drive carrier
3. hard-drive carrier handle
Figure 24. Removing and installing a 1.8 inch hot-swap hard drive
1. release button 2. hard-drive carrier
3. hard-drive carrier handle
70
Installing a hot-swap hard drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
CAUTION: Use only hard drives that have been tested and approved for use with the hard-drive
backplane.
CAUTION: Combining SAS and SATA hard drives in the same RAID volume is not supported.
CAUTION: When installing a hard drive, ensure that the adjacent drives are fully installed.
Inserting a hard-drive carrier and attempting to lock its handle next to a partially installed carrier
can damage the partially installed carrier's shield spring and make it unusable.
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive
installation. See the documentation supplied with your operating system.
CAUTION: When a replacement hot-swappable hard drive is installed and the system is powered
on, the hard drive automatically begins to rebuild. Make absolutely sure that the replacement
hard drive is blank or contains data that you wish to have over-written. Any data on the
replacement hard drive is immediately lost after the hard drive is installed.
Steps
1. If a hard-drive blank is installed in the hard-drive slot, remove it.
2. Install a hard drive in the hard-drive carrier. For more information, see Installing a hard drive into a
hard-drive carrier.
3. Press the release button on the front of the hard-drive carrier and open the hard-drive carrier handle.
4. Insert the hard-drive carrier into the hard-drive slot until the carrier connects with the backplane.
5. Close the hard-drive carrier handle to lock the hard drive in place.
Next steps
Install the optional front bezel.
Removing a hard drive from a hard-drive carrier
Prerequisites
1. Keep the #1 Phillips screwdriver handy.
2. Remove the hard-drive carrier from the system.
Steps
1. Remove the screws from the slide rails on the hard-drive carrier.
2. Lift the hard drive out of the hard-drive carrier.
71
Figure 25. Removing and installing a hard drive into a hard-drive carrier
1. screw (4) 2. hard drive
3. hard-drive carrier
Installing a hard drive into a hard-drive carrier
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Keep the #1 Phillips screwdriver handy.
Steps
1. Insert the hard drive into the hard-drive carrier with the connector end of the hard drive toward the
back.
2. Align the screw holes on the hard drive with the set of screw holes on the hard-drive carrier.
When aligned correctly, the back of the hard drive is flush with the back of the hard-drive carrier.
3. Attach the screws to secure the hard drive to the hard-drive carrier.
Removing a 1.8 inch hard drive from a hard-drive carrier
Prerequisites
1. Ensure that you read the Safety instructions.
2. Remove the hard-drive carrier from the system.
Steps
1. Turn the hard-drive carrier.
2. Pull the rails of the hard-drive carrier and lift the hard drive out of the hard-drive carrier.
72
Figure 26. Removing and installing a 1.8 hard drive into a hard-drive carrier
1. hard drive carrier 2. hard-drive
Installing a 1.8 inch hard drive into a hard-drive carrier
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
Insert the hard drive into the hard-drive carrier with the connector end of the hard drive toward the
back.
When aligned correctly, the back of the hard drive is flush with the back of the hard-drive carrier.
Optical drive (optional)
Removing the optical drive
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
73
NOTE: This procedure applies only to the 8-hard drive system.
Steps
1. Disconnect the power/data cable from the back of the drive.
Note the routing of the power/data cable on the side of the system as you remove them from the
system board and drive. You must route these cables properly when you replace them to prevent
them from being pinched or crimped.
2. To release the optical drive, press the release tab.
3. Slide the optical drive out of the system until it is free of the optical-drive slot.
4. If you are not adding a new optical drive, install the optical drive blank.
Figure 27. Removing and installing the optical drive
1. optical drive
2. power and data cable
3. release tab
Next steps
Follow the procedure listed in After working inside your system.
Installing the optical drive
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
NOTE: This procedure applies only to PowerEdge R730 systems.
74
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: This procedure applies only to the 8-hard drive system.
Steps
1. Align the optical drive with the optical drive slot on the front of the chassis.
2. Slide in the optical drive until the release tab snaps into place.
3. Connect the power/data cable to the optical drive and system board.
NOTE: You must route the cable properly on the side of the system to prevent it from being
pinched or crimped.
Next steps
Follow the procedure listed in After working inside your system.
Removing the slim optical drive blank
Follow the same procedure to remove the slim optical drive.
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the touch point for the slim optical drive blank lock inside the system.
2. Press the lock and pull the slim optical drive blank out of the chassis.
75
Figure 28. Removing and installing the slim optical drive blank
1. slim optical drive blank 2. optical drive blank lock
Installing the slim optical drive blank
Prerequisites
Ensure that you read the Safety instructions.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Align the slim optical drive blank with the slim optical drive bay.
2. Slide the optical drive blank into the optical drive bay until the lock clicks into place.
Next steps
Follow the procedure listed in After working inside your system.
Cooling fans
Your system supports hot-swappable cooling fans.
NOTE: In the event of a problem with a particular fan, the fan number is referenced by the system
management software, allowing you to easily identify and replace the proper fan by noting the fan
numbers on the cooling-fan assembly.
76
Removing a cooling fan
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
WARNING: Opening or removing the system cover when the system is ON may expose you to a
risk of electric shock. Exercise utmost care while removing or installing cooling fans.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: The cooling fans are hot-swappable. To maintain proper cooling while the system is
on, replace only one fan at a time.
CAUTION: Do not operate the system with the cover removed for a duration exceeding five
minutes.
NOTE: The procedure for removing each fan is identical.
Steps
Hold the fan and lift it out of the system.
Next steps
Figure 29. Removing and installing a cooling fan
1. cooling fans (7) 2. cooling fan connectors (7)
77
Installing a cooling fan
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: Your system supports seven hot-swappable cooling fans.
Steps
1. Align the plug at the base of the cooling fan with the connector on the system board.
2. Slide the cooling fan into the securing slots until the tabs lock into place.
Next steps
Follow the procedure listed in After working inside your system.
Internal USB memory key (optional)
An optional USB memory key installed inside your system can be used as a boot device, security key, or
mass storage device. The USB connector must be enabled by using the Internal USB Port option in the
Integrated Devices screen of the System Setup menu.
To boot from the USB memory key, configure the USB memory key with a boot image and then specify
the USB memory key in the boot sequence in the System Setup.
NOTE: To locate the internal USB connector (J_USB_INT) on the system board, see System Board
Connectors.
Replacing the internal USB key
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the USB connector or USB key on the system board.
NOTE: To locate the internal USB connector on the system board, see System board
connectors.
2. If installed, remove the USB key.
78
3. Insert the new USB key into the USB connector.
Figure 30. Replacing the internal USB key
1. USB memory key 2. USB memory key connector
Next steps
1. Follow the procedure listed in After working inside your system.
2. While booting, press <F2> to enter the System Setup and verify that the USB key is detected by the
system.
Expansion cards and expansion-card risers
NOTE: A missing or an unsupported expansion-card riser logs an SEL event. It does not prevent
your system from powering on and no BIOS POST message or F1/F2 pause is displayed.
Expansion card installation guidelines
Your system supports PCI Express Generation 3 expansion cards.
Table 3. Systems supporting three PCIe expansion cards
Riser PCIe Slot Processor
Connection Height Length Link
Width Slot Width
1 1 Processor 2 Low Profile Half Length x16 x16
1 2 Processor 2 Low Profile Half Length x8 x16
3 3 Processor 1 Low Profile Half Length x16 x16
NOTE: Both the processors must be installed to use riser 1 slots.
79
Table 4. Systems supporting two PCIe expansion cards
Riser PCIe Slot Processor
Connection Height Length Link
Width Slot Width
2 1 Processor 1 Low Profile Half Length x8 x16
Processor 2 Low Profile Half Length x16 x16
3 2 Processor 1 Full height Three-fourth
Length
x16 x16
NOTE: Only a three-fourth length card is supported for the PCIe expansion card slot (slot 2) on riser
3.
NOTE: For a server with three PCIe cards, only MiniSAS HD third party cards are supported in slot 3.
For a server with two PCIe cards, only MiniSAS HD third party cards are supported in slot 1.
NOTE: You can install expansion cards only on one slot on riser 2.
NOTE: Both the processors must be installed to use the x16 link on the riser 2 slot.
The following table provides a guide for installing expansion cards to ensure proper cooling and
mechanical fit. The expansion cards with the highest priority must be installed first using the slot priority
indicated. All other expansion cards must be installed in the specified card priority and slot priority order.
Table 5. Expansion-card installation priority
Card Priority Card Type Systems Supporting up to 2
PCIe Expansion Cards Systems Supporting up to 3 PCIe
Expansion Cards
Slot Priority Max Allowed Slot Priority Max Allowed
1 PCIe Bridge N/A N/A 1 1
2 RAID 1 1 3, 1 2
3 40 G NICs 2, 1 1 3,2 1
4 10 Gb NICs 2, 1 2 3, 2, 1 3
5 FC16 HBA 2, 1 1 3, 2, 1 1
6 FC8 HBA 2, 1 1 3, 2, 1 3
7 FC4 HBA 2, 1 1 3, 2, 1 3
8 FC16 HBA 2,1 1 N/A N/A
9 1 Gb NICs 2, 1 1 3, 2, 1 3
10 Non-RAID 2 1 N/A N/A
11 Integrated RAID Integrated Slot 1 Integrated Slot 1
12 NDC Integrated Slot 1 Integrated Slot 1
Removing an expansion card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
80
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Disconnect any cables connected to the expansion card or expansion card riser.
2. To remove the expansion card, lift the expansion-card latch.
3. Grasp the expansion card by its edges and remove it from the expansion-card connector on the
riser.
4. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot
opening and close the expansion-card latch.
NOTE: You must install a filler bracket over an empty expansion slot to maintain Federal
Communications Commission (FCC) certification of the system. The brackets also keep dust
and dirt out of the system and aid in proper cooling and airflow inside the system.
Figure 31. Removing and installing the expansion card
1. expansion connector 2. expansion card latch
3. expansion-card 4. expansion-card latch
Next steps
Follow the procedure listed in After working inside your system.
Installing an expansion card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
81
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: The expansion-card riser 1 and the x16 link on the riser 2 slot can be used only when both
the processors are installed.
Steps
1. Unpack the expansion card and prepare it for installation.
For instructions, see the documentation accompanying the card.
2. Locate the expansion-card connector on the system board/riser.
3. Open the expansion-card latch and remove the filler bracket.
4. Holding the card by its edges, position the card so that the card-edge connector aligns with the
expansion-card connector.
5. Insert the card-edge connector firmly into the expansion-card connector until the card is fully
seated.
6. Slide the expansion-card latch into position.
Next steps
1. Follow the procedure listed in After working inside your system.
2. Install any device drivers required for the card as described in the documentation for the card.
Removing expansion-card risers
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: The expansion-card riser 1 and the x16 link on the riser 2 slot can be used only when both
the processors are installed.
Steps
1. Holding the touch points, lift the expansion-card riser from the riser connector on the system board.
82
Figure 32. Removing and installing the expansion card riser 1
1. expansion-card riser 1 2. connector
3. riser guide pin
83
Figure 33. Removing and installing the expansion card riser 3
1. connector 2. expansion card riser 3
3. expansion card release latch
2. If applicable, remove or install an expansion card on the riser.
3. Replace the expansion-card riser.
Next steps
Follow the procedure listed in After working inside your system.
Installing expansion card risers
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. If applicable, reinstall the expansion card(s) into the expansion card riser.
2. Align the expansion-card riser with the connector and the riser guide pin on the system board.
3. Lower the expansion-card riser into place until the expansion-card riser connector is fully seated in
the connector.
84
Next steps
1. Follow the procedure listed in After working inside your system.
2. Install any device drivers required for the card as described in the documentation for the card.
SD vFlash media card
A vFlash SD card is a Secure Digital (SD) card that plugs into the vFlash SD card slot in the system. It
provides persistent on-demand local storage and a custom deployment environment that allows
automation of server configuration, scripts, and imaging. It emulates USB device(s). For more information,
see the Integrated Dell Remote Access Controller User’s Guide at dell.com/esmmanuals.
Replacing a SD vFlash card
Prerequisites
NOTE: This procedure applies only to the 8-hard drive system.
Steps
1. Locate the vFlash media slot on the system.
2. To remove the installed SD vFlash card, push inward on the card to release it and pull the card from
the card slot.
Figure 34. Removing and installing the SD vFlash card
1. SD vFlash card 2. SD vFlash card slot
3. To install the SD vFlash card, with the label side facing up, insert the contact-pin end of the SD card
into the card slot on the module.
NOTE: The slot is keyed to ensure correct insertion of the card.
4. Press inward on the card to lock it into the slot.
Internal dual SD module
NOTE: When the Redundancy option is set to Mirror Mode in the Integrated Devices screen of the
System Setup, the information is replicated from one SD card to another.
85
Removing the internal dual SD module
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the internal dual SD module the system board.
2. If installed, remove the SD card(s).
3. Hold the plastic pull tab and pull the dual SD module out of the system board.
86
Figure 35. Removing and installing the Internal Dual SD Module (IDSDM)
1. Internal Dual SD module 2. LED status indicator (2)
3. SD card (2) 4. SD card slot 2
5. SD card slot 1 6. IDSDM connector
The following table describes the IDSDM indicator codes.
Convention IDSDM indicator code Condition
A Green Indicates that the card is online
B Flashing green Indicates rebuild or activity
87
Convention IDSDM indicator code Condition
C Flashing amber Indicates card mismatch or that the card has
failed
D Amber Indicates that the card is offline, has failed, or is
write protected
E Not lit Indicates that the card is missing or is booting
Next steps
Follow the procedure listed in After working inside your system.
Installing the internal dual SD module
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the IDSDM connector on the system board.
2. Align the connectors on the system board and the dual SD module.
3. Push the dual SD module until it is firmly seated on the system board.
Next steps
1. Install the SD vFlash media card(s).
2. Follow the procedure listed in After working inside your system.
Internal SD card
Removing an internal SD Card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
88
Steps
Locate the SD card slot on the internal dual SD module or the backplane expander board and press
inward on the card to release it from the slot and remove the card.
Next steps
Follow the procedure listed in After working inside your system.
Installing an internal SD card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: To use an SD card with your system, ensure that the internal SD card port is enabled in the
System Setup.
Steps
1. Locate the SD card connector on the internal dual SD module or the backplane expander board.
With the label side facing up, insert the contact-pin end of the card into the slot.
NOTE: The slot is keyed to ensure correct insertion of the card.
2. Press the card into the card slot to lock it into place.
Next steps
Follow the procedure listed in After working inside your system.
Integrated storage controller card
Your system includes a dedicated expansion-card slot on the system board for an integrated controller
card that provides the integrated storage subsystem for your system’s internal hard drives. The controller
supports SAS and SATA hard drives and also enables you to set up the hard drives in RAID configurations
as supported by the version of the storage controller included with your system.
Removing the integrated storage controller card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
4. Remove the expansion-card riser 1.
5. Keep the #2 Phillips screwdriver handy.
89
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Loosen the screws that secure the integrated storage controller cable to the integrated storage-
controller card connector on the system board.
2. Lift the integrated storage controller cable out.
3. Lift one end of the card and angle it to disengage the card from the integrated storage-controller
card holder on system board.
4. Lift the card out of the chassis.
Figure 36. Removing and installing the integrated storage controller card
1. integrated storage controller cable 2. integrated storage controller card
3. integrated storage-controller card
connector on the system board 4. integrated storage controller card
holder
Next steps
1. Replace the expansion-card riser 1.
90
2. Replace the cooling shroud.
3. Follow the procedure listed in After working inside your system.
Installing the integrated storage controller card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
4. Remove the expansion-card riser 1.
5. Keep the #2 Phillips screwdriver handy.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Align the end of the integrated storage-controller card opposite the connector with the integrated
storage-controller card holder.
2. Lower the connector side of the integrated storage-controller card into the integrated storage-
controller card connector on the system board.
Ensure that the tabs on the system board align with the screw holes on the integrated storage-
controller card.
3. Align the screws on the integrated storage-controller card cable with the screw holes on the
connector.
4. Tighten the screws to secure the integrated storage-controller card cable with the integrated
storage-controller card connector on the system board.
Next steps
1. Replace the expansion-card riser 1.
2. Replace the cooling shroud.
3. Follow the procedure listed in After working inside your system.
Network daughter card
CAUTION: If the GPU card is installed, you cannot install the 10 GbE network daughter card.
Removing the network daughter card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #2 Philips screwdriver handy.
91
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Remove the expansion-card riser 3.
2. Using a #2 Phillips screwdriver, loosen the two captive screws that secure the network daughter card
to the system board.
3. Hold the network daughter card by the edges on either side of the touch points and lift to remove it
from the connector on the system board.
4. Slide the network daughter card away from the back of the system until the Ethernet connectors are
clear of the slot in the back panel.
5. Lift the network daughter card out of the system.
Example
Figure 37. Removing and installing the network daughter card
1. captive screw socket (2) 2. connector on the system board
92
3. captive screw (2) 4. touch point (2)
5. network daughter card 6. back panel slots for Ethernet connectors
Installing the network daughter card
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #1 Philips screwdriver handy.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: If the server has three PCIe cards, ensure that you install the PCIe cooling shroud in your
system.
Steps
1. Angle the card so that the Ethernet connectors fit through the slot in the back panel.
2. Align the captive screws at the back-end of the card with the screw holes on the system board.
3. Press the touch point on the card to ensure that the connector on the card is in contact with the
connector on the system board.
4. Using a #2 Phillips screwdriver, tighten the two captive screws to secure the network daughter card
to the system board.
5. Install the expansion-card riser 3.
Next steps
Follow the procedure listed in After working inside your system.
Processors
Use the following procedure when:
• Installing an additional processor
• Replacing a processor
NOTE: To ensure proper system cooling, you must install a processor blank and a heat-sink blank in
any empty processor socket.
Removing a processor
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: To ensure proper system cooling, you must install a processor blank in any empty processor
socket.
93
1. Ensure that you read the Safety instructions.
2. Keep the #2 Phillips screwdriver handy.
3. If you are upgrading your system, download the latest system BIOS version from dell.com/support
and follow the instructions included in the compressed download file to install the update on your
system.
NOTE: You can update the system BIOS using the Lifecycle Controller.
4. Follow the procedure listed in Before working inside your system.
5. If installed, remove the full-length PCIe card(s).
6. Remove the cooling shroud.
WARNING: The heat sink and processor are hot to the touch for some time after the system has
been powered down. Allow the heat sink and processor to cool before handling them.
CAUTION: Never remove the heat sink from a processor unless you intend to remove the
processor. The heat sink is necessary to maintain proper thermal conditions.
Steps
1. To remove the heat sink:
a. Loosen one of the screws that secure the heat sink to the system board.
Wait 30 seconds for the heat sink to loosen from the processor.
b. Remove the screw diagonally opposite the screw you first removed.
c. Repeat the procedure for the remaining two screws.
d. Remove the heat sink.
Figure 38. Removing and installing a processor heat sink
1. captive screw (4) 2. heat sink
3. processor socket 4. slot (4)
94
CAUTION: The processor is held in its socket under strong pressure. Be aware that the
release lever can spring up suddenly if not firmly grasped.
Figure 39. Processor shield
1. close first socket release lever 2. lock icon
3. processor 4. open first socket release lever
5. unlock icon
2. To remove the processor:
a. Release the open first socket-lever near the unlock icon by pushing the lever down and out
from under the tab.
b. Similarly, release the close first socket-release lever near the lock icon by pushing the lever
down and out from under the tab. Lift the lever 90 degrees upward.
c. Lower the open first socket-release lever to lift the processor shield.
95
Figure 40. Removing and installing a processor
1. close first socket-release lever 2. pin-1 indicator of processor
3. processor 4. slot (4)
5. processor shield 6. open first socket-release lever
7. socket 8. socket keys (4)
d. Hold the tab on the processor shield and lift the processor shield until the open first socket-
release lever lifts up.
CAUTION: The socket pins are fragile and can be permanently damaged. Be careful not to
bend the pins in the socket when removing the processor out of the socket.
e. Lift the processor out of the socket and leave the open first socket-release lever up.
NOTE: If you are permanently removing the processor, you must install a socket protective
cap in the vacant socket to protect the socket pins and keep the socket free of dust.
NOTE: After removing the processor, place it in an anti-static container for reuse, return, or
temporary storage. Do not touch the bottom of the processor. Touch only the side edges of
the processor.
Next steps
1. Replace the heat sink(s) and processor(s). See Installing a processor.
2. Follow the procedure listed in After working inside your system.
96
Installing a processor
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1. Ensure that you read the Safety instructions.
2. Keep the #2 Phillips screwdriver handy.
3. If you are upgrading your system, download the latest system BIOS version from dell.com/support
and follow the instructions included in the compressed download file to install the update on your
system.
NOTE: You can update the system BIOS using the Lifecycle Controller.
4. Follow the procedure listed in Before working inside your system.
5. Remove the cooling shroud.
WARNING: The heat sink and processor are hot to the touch for some time after the system
has been powered down. Allow the heat sink and processor to cool before handling them.
CAUTION: Never remove the heat sink from a processor unless you intend to remove the
processor. The heat sink is necessary to maintain proper thermal conditions.
NOTE: If you are installing a single processor, it must be installed in socket CPU1.
Steps
1. Remove the heat sink.
2. Unpack the new processor.
If the processor has previously been used in a system, remove any remaining thermal grease from
the processor using a lint-free cloth.
3. Locate the processor socket.
4. If applicable, remove the socket protective cap.
5. Release the open first socket-release lever near the unlock icon by pushing the lever down and
out from under the tab.
6. Similarly, release the close first socket-release lever near the lock icon by pushing the lever down
and out from under the tab. Lift the lever 90 degrees upward.
7. Hold the tab near the lock symbol on the processor shield and lift it up and out of the way.
8. To install the processor in the socket:
CAUTION: Positioning the processor incorrectly can permanently damage the system board
or the processor. Be careful not to bend the pins in the socket.
CAUTION: While removing or reinstalling the processor, wipe your hands of any
contaminants. Contaminants on the processor pins such as thermal grease or oil can damage
the processor.
a. Align the processor with the socket keys.
97
CAUTION: Do not use force to seat the processor. When the processor is positioned
correctly, it engages easily into the socket.
b. Align the pin-1 indicator of the processor with the triangle on the socket .
c. Place the processor on the socket such that the slots on the processor align with the socket keys.
CAUTION: Do not use force to seat the processor. When the processor is positioned
correctly, it engages easily into the socket.
d. Close the processor shield.
e. Lower the close first socket-release lever near the lock icon and push it under the tab to lock
it..
f. Similarly, lower the open first socket-release lever near the unlock icon and push it under the
tab to lock it.
9. To install the heat sink:
a. If applicable, remove the existing thermal grease from the heat sink using a clean lint-free cloth.
b. Apply thermal grease on the top of the processor. Use the thermal-grease syringe included with
your processor kit to apply the grease in a thin spiral on the top of the processor as shown in the
figure.
CAUTION: Applying too much thermal grease can result in excess grease coming in
contact with and contaminating the processor socket.
Figure 41. Applying thermal grease on the top of the processor
1. processor 2. thermal grease
98
3. thermal-grease syringe
NOTE: The thermal-grease is intended for one-time use only. Dispose of the syringe after
you use it.
c. Place the heat sink onto the processor.
d. Tighten the four screws to secure the heat sink to the system board.
NOTE: Tighten the screws diagonally opposite to each other. Do not over-tighten the heat
sink retention screws when installing the heat sink. To prevent over-tightening, tighten the
retention screw until resistance is felt, and stop once the screw is seated. The screw tension
should be no more than 6 in-lb (6.9 kg-cm).
Next steps
1. Install the cooling shroud.
2. Follow the procedure listed in After working inside your system.
3. While booting, press <F2> to enter the System Setup and check that the processor information
matches the new system configuration.
4. Run the system diagnostics to verify that the new processor operates correctly.
Power supply units
Your system supports one of the following:
• Two 495 W, 750 W, or 1100 W AC power supply modules or
• Two 1100 W DC power supply modules or
• Two 750 W mixed mode power supply modules
NOTE: Titanium power supply unit is nominally rated for 200 VAC to 240 VAC input only.
NOTE: When two identical power supplies are installed, power supply redundancy (1+1 – with
redundancy or 2+0 – without redundancy) is configured in system BIOS. In redundant mode, power
is supplied to the system equally from both power supplies when Hot Spare is disabled. When Hot
Spare is enabled, one of the PSUs will be put into standby when system utilization is low in order to
maximize efficiency.
NOTE: If two power supply units are used, they must be of the same maximum output power.
NOTE: For AC power supply units, use only power supply units with the Extended Power
Performance (EPP) label on the back. Mixing power supply units from previous generations of
servers can result in a power supply unit mismatch condition or failure to power on.
Hot Spare feature
Your system supports the Hot Spare feature that significantly reduces the power overhead associated
with power supply redundancy.
When the Hot Spare feature is enabled, one of the redundant power supplies is switched to a sleep state.
The active power supply supports 100% of the load, thus operating at higher efficiency. The power supply
in the sleep state monitors output voltage of the active power supply. If the output voltage of the active
power supply drops, the power supply in the sleep state returns to an active output state.
99
If having both power supplies active is more efficient than having one power supply in a sleep state, the
active power supply can also activate a sleeping power supply.
The default power supply settings are as follows:
• If the load on the active power supply is more than 50%, then the redundant power supply is switched
to the active state.
• If the load on the active power supply falls below 20%, then the redundant power supply is switched
to the sleep state
You can configure the Hot Spare feature using the iDRAC settings. For more information on iDRAC
settings, see the Integrated Dell Remote Access Controller User’s Guide at dell.com/support/manuals.
Removing the power supply unit blank
If you are installing a second power supply unit, remove the power supply unit blank in the bay by
pulling the blank outward.
CAUTION: To ensure proper system cooling, the power supply blank must be installed in the
second power supply bay in a non-redundant configuration. Remove the power supply blank
only if you are installing a second power supply.
100
Figure 42. Removing and installing the power supply blank
1. power supply blank 2. power supply bay
Installing the power supply unit blank
Install the power supply unit blank only in the second power supply unit bay.
To install the power supply unit blank, align the blank with the power supply unit bay and push it into
the chassis until it clicks into place.
Removing an AC power supply unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: The system requires one power supply for normal operation. On power-redundant
systems, remove and replace only one power supply at a time in a system that is powered on.
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with
power supply removal. For information about the cable management arm, see the system’s rack
documentation.
Steps
1. Disconnect the power cable from the power source and from the power supply unit you intend to
remove and remove the cables from the strap.
2. Press the release latch and slide the power supply unit out of the chassis.
101
Figure 43. Removing and installing an AC power supply unit
1. release latch 2. power supply unit cable connector
3. power supply unit 4. connector
5. power supply unit handle
Installing an AC power supply unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Verify that both the power supply units are the same type and have the same maximum output
power.
NOTE: The maximum output power (shown in watts) is listed on the power supply label.
2. If applicable, remove the power supply unit blank.
3. Slide the new power supply unit into the chassis until the power supply unit is fully seated and the
release latch snaps into place.
NOTE: If you unlatched the cable management arm, re-latch it. For information about the cable
management arm, see the system’s rack documentation.
4. Connect the power cable to the power supply unit and plug the cable into a power outlet.
CAUTION: When connecting the power cable, secure the cable with the strap.
102
NOTE: When installing, hot-swapping, or hot-adding a new power supply unit, wait for 15
seconds for the system to recognize the power supply unit and determine its status. The power
supply redundancy may not occur until discovery is complete. Wait until the new power supply
unit is discovered and enabled before you remove the other power supply unit. The power-
supply unit status indicator turns green to signify that the power supply unit is functioning
properly.
Wiring instructions for a DC power supply unit
Your system supports up to two –(48–60) V DC power supplies (when available).
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must
perform all connections to DC power and to safety grounds. Do not attempt connecting to DC
power or installing grounds yourself. All electrical wiring must comply with applicable local or
national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
CAUTION: Wire the unit with copper only, unless otherwise specified, use only 10 American Wire
Gauge (AWG) wire rated minimum 90 ºC for source and return. Protect the –(48–60) V DC (1
wire) with a branch circuit over-current protection rated 50 A for DC with a high interrupt
current rating.
CAUTION: Connect the equipment to a –(48–60) V DC supply source that is electrically isolated
from the AC source (reliably grounded –(48–60) V DC SELV source). Ensure that the –(48–60) V
DC source is efficiently secured to earth (ground).
NOTE: A readily accessible disconnect device that is suitably approved and rated shall be
incorporated in the field wiring.
Input requirements
• Supply voltage: –(48–60) V DC
• Current consumption: 32 A (maximum)
Kit contents
• Dell part number 6RYJ9 terminal block or equivalent (1)
• #6-32 nut equipped with lock washer (1)
Required tools
Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper
wire
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding)
Required wires
• One UL 10 AWG, 2 m maximum (stranded) black wire [–(48–60) V DC]
• One UL 10 AWG, 2 m maximum (stranded) red wire (V DC return)
• One UL 10 AWG, 2 m maximum green/yellow, green with a yellow stripe, stranded wire (safety
ground)
103
Removing a DC power supply unit
Prerequisites
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must
perform all connections to DC power and to safety grounds. Do not attempt connecting to DC
power or installing grounds yourself. All electrical wiring must comply with applicable local or
national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
CAUTION: The system requires one power supply for normal operation. On power-redundant
systems, remove and replace only one power supply at a time in a system that is powered on.
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with
power supply removal. For information about the cable management arm, see the system’s rack
documentation.
Steps
1. Disconnect the power wires from the power source and the connector from the power supply you
intend to remove.
2. Disconnect the safety ground wire.
3. Press the release latch and slide the power supply out of the chassis.
Figure 44. Removing and installing a DC power supply
1. release latch 2. power supply status indicator
3. power supply 4. connector
5. power supply handle
104
Installing a DC power supply unit
Prerequisites
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must
perform all connections to DC power and to safety grounds. Do not attempt connecting to DC
power or installing grounds yourself. All electrical wiring must comply with applicable local or
national codes and practices. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow all safety instructions that came with the product.
Steps
1. Verify that both the power supplies are of the same type and have the same maximum output power.
NOTE: The maximum output power (shown in watts) is listed on the power supply label.
2. If installed, remove the power supply blank.
3. Slide the new power supply unit into the chassis until the power supply unit is fully seated and the
release latch snaps into place.
NOTE: If you unlatched the cable management arm, relatch it. For information about the cable
management arm, see the system’s rack documentation.
4. Connect the safety ground wire.
5. Install the DC power connector in the power supply unit.
CAUTION: When connecting the power wires, secure the wires with the strap to the power
supply handle.
6. Connect the wires to a DC power source.
NOTE: When installing, hot-swapping, or hot-adding a new power supply, wait for 15 seconds
for the system to recognize the power supply and determine its status. The power-supply
status indicator turns green to signify that the power supply is functioning properly.
System battery
Replacing the system battery
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the cooling shroud.
WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the
battery only with the same or equivalent type recommended by the manufacturer. See your
safety information for additional information.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Locate the battery socket. For more information, see System Board Connectors.
105
CAUTION: To avoid damage to the battery connector, you must firmly support the connector
while installing or removing a battery.
2. Place your finger between the securing tabs at the negative side of the battery connector and lift the
battery out of the socket.
Figure 45. Removing the system battery
1. positive side of the battery connector
2. system battery
3. negative side of the battery connector
3. To install a new system battery, hold the battery with the "+" facing up and slide it under the securing
tabs.
4. Press the battery into the connector until it snaps into place.
106
Figure 46. Installing the system battery
1. system battery 2. positive side of the battery connector
Next steps
1. Install the cooling shroud.
2. Follow the procedure listed in After working inside your system.
3. While booting, press <F2> to enter the System Setup and ensure the battery is operating properly.
4. Enter the correct time and date in the System Setup Time and Date fields.
5. Exit the System Setup.
Hard-drive backplane
Depending on your configuration,
8–Hard-drive
system
supports
2.5 inch (x4) SAS/SATA backplane
10–Hard-drive
system
supports
2.5 inch (x10) SAS/SATA backplane that supports X10 and 4 (PCIe SSDs) + 6
24–Hard-drive
system
supports
1.8 inch (x24) SAS/SATA backplane
Removing the hard-drive backplane
Prerequisites
1. Ensure that you read the Safety instructions.
107
2. Follow the procedure listed in Before working inside your system.
3. Remove all hard drives.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: To prevent damage to the hard drives and hard-drive backplane, you must remove the
hard drives from the system before removing the hard-drive backplane.
CAUTION: You must note the number of each hard drive and temporarily label them before
removal so that you can replace them in the same locations.
Steps
1. Disconnect the SAS/SATA/SSD data cable(s) and power cable from the backplane.
2. If applicable, disconnect the power/data cable from the optical drive.
3. Push the backplane blue release tabs in the direction of the arrows and lift the backplane upwards.
4. Pull the backplane away from the system until the securing slots on the backplane are free from the
tabs on the chassis.
Figure 47. Removing and installing the 2.5 Inch (x8) hard-drive backplane
1. backplane 2. backplane signal cable
3. backplane signal cable 4. SAS A cable
5. release tabs (2) 6. SAS B cable
7. SAS hard-drive connector on backplane
108
Figure 48. Cabling diagram—2.5 Inch (x8) systems
1. SAS backplane 2. signal connector on system board
3. system board 4. SAS A connector on system board
5. SAS B connector on system board
109
Figure 49. Removing and installing the 2.5 Inch (x10) hard-drive backplane
1. SD signal cable 2. SD signal cable connector
3. SAS cables(2) 4. SAS cable connector (2)
5. guide pin 6. guide pin slot
7. hard-drive connector 8. SAS backplane
110
Figure 50. Cabling diagram—2.5 Inch (x10) systems
1. SAS backplane expander card 2. signal cable connector on the system
board
3. system board 4. integrated storage controller card
111
Figure 51. Removing and installing the 1.8 Inch (x24) hard-drive backplane
1. SD signal cable (3) 2. SD signal cable connector (2)
3. SAS cables(4) 4. SAS cable connector (4)
5. guide pin 6. guide pin slot
7. SAS backplane 8. release tab (2)
112
Figure 52. Cabling diagram—1.8 Inch (x24) systems
1. SAS backplane 2. SD signal cable connector
3. SAS backplane expander card 4. SD signal cable connector
5. SD signal cable connector 6. system board
7. integrated storage controller card 8. SAS connector on system board
9. SAS connector on system board
Installing the hard-drive backplane
Prerequisites
1. Ensure that you read the Safety instructions.
113
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Use the hooks on the chassis as guides to align the hard-drive backplane.
2. Lower the hard-drive backplane until the release tabs snap into place.
3. Connect the SAS/SATA/SSD data, signal, and power cable(s) to the backplane.
Next steps
1. Install the hard drives in their original locations.
2. Follow the procedure listed in After working inside your system.
Control Panel Assembly
Removing the control panel board–8 hard drive system
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #2 Philips screwdriver ready.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure that the
locking tab on the connector is released before removal and insertion. The locking tab must be
engaged after insertion.
Steps
1. Disconnect the control panel and display module cables from the control panel board.
2. Using a #2 Phillips screwdriver, remove the two screws that secure the control panel board to the
chassis.
3. Slide the control panel board toward the back and out of the system.
114
Figure 53. Removing and installing the control panel board
1. control panel board 2. screws (2)
3. control-panel cable 4. display module cable
Installing the control panel board–8 hard drive system
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Keep the #2 Philips screwdriver ready.
Steps
1. Align the screw holes on the control panel board with the standoffs on the chassis.
2. Using a #2 Phillips screwdriver, replace the two screws that secure the control panel board to the
chassis.
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure
that the locking tab on the connector is released before removal and insertion. The locking
tab must be engaged after insertion.
3. Connect control panel and display module cables to the control panel board.
4. If required, route the power/data cables along the chassis wall.
115
Next steps
Follow the procedure listed in After working inside your system.
Removing the control panel–8 hard–drive system
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #1 Philips screwdriver ready.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure that the
locking tab on the connector is released before removal and insertion. The locking tab must be
engaged after insertion.
Steps
1. Disconnect the display module cable from the control panel board.
2. Using a #1 Philips screwdriver, remove the screw (located at the bottom of the chassis) that secures
the control module to the chassis.
NOTE: Apart from the screw, the control panel has three tabs (one on the left and two tabs on
top) that secure it to the chassis.
CAUTION: Applying excessive force while pulling upward may damage the control panel.
3. Hold the top edge of the control panel at the corners and pull upward until the control panel tabs are
released.
4. Hold the right edge of the control panel and rotate it toward the left until it is released from the
chassis.
5. Pull the control panel away from the chassis.
116
Figure 54. Removing and installing the control panel
1. control panel 2. notch on chassis front wall (2)
3. display module ZIF connector 4. display module cable
Installing the control panel–8 hard drive system
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Keep the #1 Philips screwdriver ready.
Steps
1. Slide the left side of the control panel into the chassis so that the left tab on the control panel aligns
with the slot on the chassis wall and the top left tab aligns with the slot on the top of the chassis.
2. Pull the display module cable through the opening and into the chassis.
3. Push the right side of the control panel until the top right tab aligns with the top of the chassis and
the panel snaps into place.
4. Using a #1 Philips screwdriver, replace the screw (located at the bottom of the chassis) that secures
the control module to the chassis.
117
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure
that the locking tab on the connector is released before removal and insertion. The locking
tab must be engaged after insertion.
5. Connect the display module cable to the control panel board.
Next steps
Follow the procedure listed in After working inside your system.
Removing the control panel–10 hard–drive and 24–hard drive system
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Keep the #1 Philips screwdriver ready.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Using a #1 Philips screwdriver, remove the screw (located at the bottom of the chassis) that secures
the control panel to the chassis.
2. Remove the control panel cable from the connectors on the system board (J_CP and J_FP_USB) and
the hard-drive expander card.
NOTE: To locate the connectors on the system board, see System Board Connectors.
3. Press the control panel latch and slide the control panel out of the chassis.
4. Disconnect the control panel cable from the control panel.
118
Next steps
Figure 55. Removing and installing the control panel
1. control panel release latch 2. cable securing clip
3. control panel cable connecting to system
board 4. J_FP_USB connector cable
5. screw 6. control panel
Installing the control panel–10 hard–drive system and 24 hard–drive system
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Keep the #1 Philips screwdriver ready.
Steps
1. Route the control panel cable through the chassis and connect the control panel cable to the
control panel.
2. Push the control panel into the chassis till it snaps into place.
119
3. Using a #1 Philips screwdriver, replace the screw (located at the bottom of the chassis) that secures
the control panel to the chassis.
4. Locate the connectors J_CP and J_FP_USB on the system board.
NOTE: To locate the connectors on the system board, see System Board Connectors.
5. Connect the control panel cable to the connectors on the system board (J_CP and J_FP_USB) and
the hard-drive expander card.
NOTE: Ensure that the control panel cable inside the system is routed along the chassis wall
and secured using the cable securing bracket.
Next steps
Follow the procedure listed in After working inside your system.
VGA Module
NOTE: Only the 8-hard drive system has a VGA module on the front panel.
Removing the VGA module
Prerequisites
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: This procedure applies only to the 8-hard drive system.
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure that the
locking tab on the connector is released before removal and insertion. The locking tab must be
engaged after insertion.
Steps
1. Disconnect the display module cable from the control panel board.
2. Remove the control panel.
3. Disconnect the VGA module cable from the VGA module.
4. Using a #2 Philips screwdriver, remove the screw that secures the VGA module to the chassis.
5. Slide the VGA module out of the chassis.
120
Figure 56. Removing and Installing the VGA Module
1. screw 2. VGA module cable
3. VGA module 4. control panel
Installing the VGA module
Prerequisites
NOTE: This procedure applies only to the 8-hard drive system.
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Push the VGA module into the chassis and align the threaded screw hole on the VGA module with
the screw hole on the chassis.
2. Using a #2 Philips screwdriver, replace the screw (at the bottom of the chassis) that secures the VGA
module to the chassis.
3. Replace the control panel.
4. Connect the VGA module cable to the VGA module.
121
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure
that the locking tab on the connector is released before removal and insertion. The locking
tab must be engaged after insertion.
5. Connect the display module cables to the control panel board.
Next steps
Follow the procedure listed in After working inside your system.
System board
Removing the system board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: If you are using the Trusted Platform Module (TPM) with an encryption key, you may
be prompted to create a recovery key during program or System Setup. Be sure to create and
safely store this recovery key. If you replace this system board, you must supply the recovery key
when you restart your system or program before you can access the encrypted data on your hard
drives.
CAUTION: Do not attempt to remove the TPM plug-in module from the motherboard. Once the
TPM plug-in module is installed, it is cryptographically bound to that specific motherboard. Any
attempt to remove an installed TPM plug-in module breaks the cryptographic binding, and it
cannot be re-installed or installed on another motherboard.
1. Ensure that you read the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the following:
a. cooling shroud
b. memory modules
c. cooling fans
d. power supply(s)
e. all expansion-card risers and expansion cards
WARNING: The heat sink is hot to touch for some time after the system has been
powered down. Ensure that you do not touch the heat sink(s) while removing the
system board.
f. heat sink(s)/heat-sink blanks and processors(s)/processor blanks
CAUTION: To prevent damage to the processor pins when replacing a faulty system
board, ensure that you cover the processor socket with the processor protective cap.
g. integrated storage controller card
h. network daughter card
i. internal dual SD module
122
j. internal USB key (if installed)
k. hot-swap hard drives
l. hard-drive backplane
CAUTION: To avoid damaging the mini SAS cable and connector, follow the correct
procedure when removing the mini SAS cable from the system board.
Steps
1. Disconnect the mini SAS cable from the system board:
a. Push the mini SAS cable connector to slide it further into the connector on the system board.
b. Press down and hold the metal tab on the mini SAS cable connector.
c. Pull the mini SAS cable out of the connector on the system board.
2. Disconnect all other cables from the system board.
CAUTION: Take care not to damage the system identification button while removing the
system board from the chassis.
3. Grasp the system-board holder, lift the blue release pin, slide the system board toward the front of
the system, and lift the system board out of the chassis.
CAUTION: Do not lift the system board assembly by grasping a memory module, processor,
or other components.
123
Figure 57. Removing and Installing the System Board
1. system board holder 2. system-board
3. release pin
Installing the system board
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
124
Steps
1. Unpack the new system board assembly.
CAUTION: Do not lift the system board assembly by grasping a memory module, processor,
or other components.
CAUTION: Take care not to damage the system identification button while placing the
system board into the chassis.
2. Hold the touch points and lower the system board into the chassis.
3. Push the system board toward the back of the chassis until the board is seated correctly.
Next steps
1. Install the Trusted Platform Module (TPM). For information on how to install TPM, Installing the
Trusted Platform Module. For more information on TPM, see Trusted Platform Module.
2. Replace the following:
a. cable retention bracket
b. PCIe card holder
c. integrated storage controller card
d. internal USB key (if installed)
e. internal dual SD module
f. all expansion-card risers
g. heat sink(s)/heat-sink blank(s) and processors(s)/processor blank(s)
h. memory modules and memory module blanks
i. network daughter card
j. cooling-fan assembly
k. cooling shroud
l. power supply unit(s)
3. Reconnect all cables to the system board.
NOTE: Ensure that the cables inside the system are routed along the chassis wall and secured
using the cable securing bracket.
4. Follow the procedure listed in After working inside your system.
5. Import your new or existing iDRAC Enterprise license. For more information, see the Integrated Dell
Remote Access Controller User's Guide, at dell.com/esmmanuals.
6. Ensure that you:
a. Use the Easy Restore feature to restore the service tag. For more information, see Easy
Restore.
b. If the service tag is not backed up in the backup flash device, enter the system service tag
manually. For more information, see Entering the system service tag.
c. Update the BIOS and iDRAC versions.
d. Re-enable the Trusted Platform Module (TPM). For more information, see Re-enabling the TPM
for BitLocker users or Re-enabling the TPM for Intel TXT users.
125
Entering the system service tag using System Setup
If you know the system service tag, use the System Setup menu to enter the service tag.
1. Turn on the system.
2. Press <F2> to enter the System Setup.
3. Click Service Tag Settings.
4. Enter the service tag.
NOTE: You can enter the service tag only when the Service Tag field is empty. Ensure that you
enter the correct service tag. Once the service tag is entered, it cannot be updated or changed.
5. Click Ok.
Restoring the service tag using Easy Restore
Use the Easy Restore feature if you do not know the service tag of your system. The Easy Restore feature
allows you to restore your system’s service tag, license, UEFI configuration, and the system configuration
data after replacing the system board. All data is backed up in a backup flash device automatically. If BIOS
detects a new system board and the service tag in the backup flash device, BIOS prompts the user to
restore the backup information.
1. Turn on the system.
If BIOS detects a new system board, and if the service tag is present in the backup flash device, BIOS
displays the service tag, the status of the license, and the UEFI Diagnostics version.
2. Do one of the following:
• Press Y to restore the service tag, license, and diagnostics information.
• Press N to navigate to the Lifecycle Controller based restore options.
• Press <F10> to restore data from a previously created Hardware Server Profile.
After the restore process is complete, BIOS prompts to restore the system configuration data.
3. Do one of the following:
• Press Y to restore the system configuration data.
• Press N to use the default configuration settings.
After the restore process is complete, the system reboots.
Trusted Platform Module
The Trusted Platform Module (TPM) is used to generate/store keys, protect/authenticate passwords, and
create/store digital certificates. TPM can also be used to enable the BitLocker hard drive encryption
feature in Windows Server.
Installing the Trusted Platform Module
Prerequisites
Ensure that you read the Safety instructions.
CAUTION: Do not remove an installed Trusted Platform Module (TPM). Any attempt to remove an
installed TPM from the system board may damage the TPM.
126
Steps
1. Align the edge connectors on the TPM with the slot on the TPM connector.
2. Insert the TPM into the TPM connector such that the plastic bolt aligns with the slot on the system
board.
3. Press the plastic bolt until the bolt snaps into place.
Figure 58. Installing the TPM
1. TPM 2. TPM connector
3. slot on the TPM connector 4. plastic bolt
5. slot on the system board
Re-enabling the TPM for BitLocker users
Initialize the TPM.
For more information on initializing the TPM, see http://technet.microsoft.com/en-us/library/
cc753140.aspx.
The TPM Status changes to Enabled, Activated.
Re-enabling the TPM for TXT users
1. While booting your system, press <F2> to enter System Setup.
2. In the System Setup Main Menu, click System BIOS → System Security Settings.
3. In the TPM Security option, select On with Pre-boot Measurements.
4. In the TPM Command option, select Activate.
5. Save the settings.
6. Reboot your system.
127
7. Enter System Setup again.
8. In the System Setup Main Menu, click System BIOS → System Security Settings.
9. In the Intel TXT option, select On.
128
5
Troubleshooting your system
Safety first—for you and your system
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Troubleshooting system startup failure
If you boot the system to the BIOS boot mode after installing an operating system from the UEFI Boot
Manager, the system hangs. The reverse is also true. You must boot to the same boot mode in which you
installed the operating system.
For all other startup issues, note the system messages that appear on the screen.
Troubleshooting external connections
Ensure that all external cables are securely attached to the external connectors on your system before
troubleshooting any external devices.
Troubleshooting the video subsystem
1. Check the system and power connections to the monitor.
2. Check the video interface cabling from the system to the monitor.
3. Run the appropriate diagnostic test.
If the tests run successfully, the problem is not related to video hardware.
If the tests fail, see Getting Help.
Troubleshooting a USB device
About this task
Use the following steps to troubleshoot a USB keyboard/mouse. For other USB devices, go to step 7.
Steps
1. Disconnect the keyboard and mouse cables from the system and reconnect them.
2. If the problem persists, connect the keyboard/mouse to the USB port(s) on the opposite side of the
system.
129
3. If the problem is resolved, restart the system, enter the System Setup, and check if the non-
functioning USB ports are enabled.
Check if USB 3.0 is enabled in System Setup. If enabled, disable it and see if the issue is resolved
(older operating systems may not support USB 3.0).
4. In the IDRAC Settings Utility, ensure the USB Management Port Mode is configured as Automatic or
Standard OS Use.
5. Replace the keyboard/mouse with a working keyboard/mouse.
If the problem is not resolved, proceed to the next step to begin troubleshooting other USB devices
attached to the system.
6. Power down all attached USB devices and disconnect them from the system.
7. Reboot the system and, if your keyboard is functioning, enter the System Setup.
8. Verify that all USB ports are enabled on the Integrated Devices screen, in the System Setup options.
9. Check if USB 3.0 is enabled in System Setup. If it is enabled, disable it and restart your system.
If your keyboard is not functioning, you can also use remote access.
10. If the system is not accessible, reset the NVRAM_CLR jumper inside your system and restore the
BIOS to the default settings.
11. In the IDRAC Settings Utility, ensure the USB Management Port Mode is configured as Automatic or
Standard OS Use.
12. Reconnect and power on each USB device one at a time.
13. If a USB device causes the same problem, power down the device, replace the USB cable with a
known good cable, and power up the device.
Next steps
If all troubleshooting fails, see Getting Help.
Troubleshooting iDRAC Direct (USB XML configuration)
For information on USB storage device and server configuration, see the Integrated Dell Remote Access
Controller User's Guide at dell.com/esmanuals.
Steps
1. Ensure your USB storage device is connect to the front USB Management Port, identified by
icon.
2. Ensure your USB storage device is configured with an NTFS or a FAT32 file system with only one
partition.
3. Verify that the USB storage device is configured correctly. For more information on configuring the
USB storage device, see the Integrated Dell Remote Access Controller User's Guide at dell.com/
esmanuals.
4. In the IDRAC Settings Utility, ensure the USB Management Port Mode is configured as Automatic or
iDRAC Direct Only.
5. Make sure the iDRAC Managed: USB XML Configuration option is either Enabled or Enabled only
when the server has default credential settings.
6. Remove and re-insert the USB storage device.
7. If import operation does not work, try with a different USB storage device.
Next steps
If all troubleshooting fails, see Getting help.
130
Troubleshooting iDRAC Direct (laptop connection)
For information on USB laptop connection and server configuration, see the Integrated Dell Remote
Access Controller User's Guide at dell.com/esmanuals.
Steps
1. Make sure your laptop is connected to the front USB Management Port, identified by icon with
a USB Type A/A cable.
2. In the IDRAC Settings Utility, ensure the USB Management Port Mode is configured as Automatic or
iDRAC Direct Only.
3. If the laptop is running the Windows operating system, ensure the iDRAC Virtual USB NIC device
driver is installed.
4. If the driver is installed, ensure you are not connected to any network through WiFi or cabled
ethernet as iDRAC Direct uses a non-routable address.
Next steps
If all troubleshooting fails, see Getting help.
Troubleshooting a serial I/O device
Steps
1. Turn off the system and any peripheral devices connected to the serial port.
2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.
If the problem is resolved, replace the interface cable with a known good cable.
3. Turn off the system and the serial device, and swap the serial device with a comparable device.
4. Turn on the system and the serial device.
Next steps
If the problem persists, see Getting Help.
Troubleshooting a NIC
Steps
1. Run the appropriate diagnostic test. See Using System Diagnostics for available diagnostic tests.
2. Reboot the system and check for any system messages pertaining to the NIC controller.
3. Check the appropriate indicator on the NIC connector:
• If the link indicator does not light, check all cable connections.
• If the activity indicator does not light, the network driver files might be damaged or missing.
Remove and reinstall the drivers if applicable. See the NIC's documentation.
• If applicable, change the autonegotiation setting.
• Use another connector on the switch or hub.
4. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's
documentation.
5. Enter the System Setup and confirm that the NIC ports are enabled on the Integrated Devices
screen.
6. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission
speed and duplex. See the documentation for each network device.
131
7. Ensure that all network cables are of the proper type and do not exceed the maximum length.
Next steps
If all troubleshooting fails, see Getting Help.
Troubleshooting a wet system
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2. Remove the system cover.
3. Remove the following components from the system:
• hard drives
• hard-drive backplane
• USB memory key
• hard-drive tray
• cooling shroud
• expansion-card risers (if present)
• expansion cards
• power supply unit(s)
• cooling-fan assembly (if present)
• cooling fans
• processor(s) and heat sink(s)
• memory modules
4. Let the system dry thoroughly for at least 24 hours.
5. Reinstall the components you removed in step 3.
6. Install the system cover.
7. Turn on the system and attached peripherals.
If the system does not start properly, see Getting Help.
8. If the system starts properly, shut down the system, and reinstall all the expansion cards that you
removed.
9. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Next steps
If the tests fail, see Getting Help.
132
Troubleshooting a damaged system
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2. Remove the system cover.
3. Ensure that the following components are properly installed:
• Cooling shroud
• Expansion-card risers (if present)
• Expansion cards
• Power supply(s)
• Cooling-fan assembly (if present)
• Cooling fans
• Processor(s) and heat sink(s)
• Memory modules
• Hard-drive carriers
• Hard-drive backplane
4. Ensure that all cables are properly connected.
5. Install the system cover.
6. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Next steps
If the tests fail, see Getting Help.
Troubleshooting the system battery
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may
lose its system configuration information. This situation is caused by a defective battery.
NOTE: Some software may cause the system time to speed up or slow down. If the system seems
to operate normally except for the time kept in the System Setup, the problem may be caused by
software rather than by a defective battery.
133
Steps
1. Re-enter the time and date in the System Setup.
2. Turn off the system and disconnect it from the electrical outlet for at least one hour.
3. Reconnect the system to the electrical outlet and turn on the system.
4. Enter the System Setup.
If the date and time are not correct in the System Setup, check the SEL for system battery messages.
Next steps
If the problem persists, see Getting Help.
Troubleshooting power supply units
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Power source problems
1. Press the power button to ensure that your system is turned on. If the power indicator does not light
up when the power button is pressed, press the power-on button firmly.
2. Plug in another working device to ensure that the system board is not faulty.
3. Ensure that no loose connections exist.
For example, loose power cables.
4. Ensure that the power source meets applicable standards.
5. Ensure that there are no short circuits.
6. Have a qualified electrician check the line voltage to ensure that it meets the required specifications.
Power supply unit problems
1. Ensure that no loose connections exist.
For example, loose power cables.
2. Ensure that the power supply handle/LED indicates that the power supply is working properly.
For more information on power supply indicators, see Power indicator codes.
3. If you have recently upgraded your system, ensure that the power supply unit has enough power to
support the new system.
4. If you have a redundant power supply configuration, ensure that both the power supply units are of
the same type and wattage.
If the LED You may have to upgrade to a higher wattage power supply unit.
5. Ensure that you use only power supply units with the Extended Power Performance (EPP) label on
the back.
6. Reseat the power supply unit.
NOTE: After installing a power supply unit, allow several seconds for the system to recognize
the power supply unit and determine if it is working properly.
If the problem persists, see Getting Help.
134
Troubleshooting cooling problems
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Ensure that the following conditions exist:
• System cover, cooling shroud, EMI filler panel, or back-filler bracket is not removed.
• Ambient temperature is not too high.
• External airflow is not obstructed.
• A cooling fan is not removed or has not failed.
• The expansion card installation guidelines have been followed.
Additional cooling can be added by one of the following methods:
From the iDRAC Web GUI:
1. Click Hardware → Fans → Setup.
2. From the Fan Speed Offset drop-down list, select the cooling level needed or set the minimum fan
speed to a custom value.
From F2 System Setup
1. Select iDRAC Settings → Thermal, and set a higher fan speed from the fan speed offset or minimum
fan speed.
From RACADM commands
1. Run the command racadm help system.thermalsettings
For more information, see the Integrated Dell Remote Access Controller User's Guide at dell.com/
esmmanuals.
Troubleshooting cooling fans
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: In the event of a problem with a particular fan, the fan number is referenced by the system’s
management software, allowing you to easily identify and replace the proper fan by noting the fan
numbers on the cooling fan assembly.
Steps
1. Remove the system cover.
2. Reseat the fan or the fan's power cable.
135
3. If the fan functions properly, install the system cover.
Next steps
If the problem persists, see Getting Help.
Troubleshooting system memory
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. If the system is operational, run the appropriate diagnostic test. See Using system diagnostics for
available diagnostic tests.
If diagnostics indicate a fault, follow the corrective actions provided by the diagnostic program.
2. If the system is not operational, turn off the system and attached peripherals, and unplug the system
from the power source. Wait at least 10 seconds and then reconnect the system to the power
source.
3. Turn on the system and attached peripherals and note the messages on the screen.
If an error message is displayed indicating a fault with a specific memory module, go to step 12.
4. Enter the System Setup and check the system memory setting. Make any changes to the memory
settings, if needed.
If the memory settings match the installed memory but the problem still persists, go to step 12.
5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6. Remove the system cover.
7. Check the memory channels and ensure that they are populated correctly.
NOTE: See the system event log or system messages for the location of the failed memory
module. Reinstall the memory device.
8. Reseat the memory modules in their sockets.
9. Install the system.
10. Enter the System Setup and check the system memory setting.
If the problem is not resolved, proceed with the next step.
11. Remove the system cover.
12. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace
the module with a known good memory module.
13. To troubleshoot an unspecified faulty memory module, replace the memory module in the first
DIMM socket with a module of the same type and capacity.
If an error message is displayed on the screen, this may indicate a problem with the installed DIMM
type(s), incorrect DIMM installation, or defective DIMM(s). Follow the on-screen instructions to
resolve the problem. For more information, see General memory module installation guidelines.
14. Install the system cover.
15. As the system boots, observe any error message that is displayed and the diagnostic indicators on the
front of the system.
16. If the memory problem persists, repeat step 12 through step 15 for each memory module installed.
136
Next steps
If the problem persists after all memory modules have been checked, see Getting Help.
Troubleshooting an internal USB key
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Enter the System Setup and ensure that the USB key port is enabled on the Integrated Devices
screen.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Locate the USB key and reseat it.
5. Install the system cover.
6. Turn on the system and attached peripherals and check if the USB key is functioning.
7. If the problem is not resolved, repeat step 2 and step 3.
8. Insert a different USB key that you know works properly.
9. Install the system cover.
Next steps
If the problem is not resolved, see Getting Help.
Troubleshooting an SD card
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: Certain SD cards have a physical write-protect switch on the card. If the write-protect switch
is turned on, the SD card is not writeable.
Steps
1. Enter the System Setup and ensure that the Internal SD Card Port is enabled.
2. Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
3. Remove the system cover.
NOTE: When an SD card failure occurs, the internal dual SD module controller notifies the
system. On the next reboot, the system displays a message indicating the failure. If redundancy
is enabled at the time of SD card failure, a critical alert will be logged and chassis health will
degrade.
4. Replace the failed SD card with a new SD card.
137
5. Install the system cover.
6. Reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
7. Enter the System Setup and ensure that the Internal SD Card Port and Internal SD Card Redundancy
mode is set to the required mode.
Verify that correct SD slot is set as Primary SD Card.
8. Check if the SD card is functioning properly.
9. If the Internal SD Card Redundancy option is set to Enabled at the time of the SD card failure, the
system will prompt you to perform a rebuild.
NOTE: The rebuild will always be sourced from the primary SD card to the secondary SD card.
Perform the rebuild of the SD card as necessary.
Troubleshooting an optical drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Try using a different CD or DVD.
2. Enter the System Setup and ensure that the integrated SATA controller and the drive's SATA port are
enabled.
3. Run the appropriate diagnostic test.
4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
5. If installed, remove the front bezel.
6. Remove the system cover.
7. Ensure that the interface cable is securely connected to the optical drive and to the controller.
8. Ensure that a power cable is properly connected to the drive.
9. Install the system cover.
Next steps
If the problem is not resolved, see Getting Help.
Troubleshooting a tape backup unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
138
Steps
1. Use a different tape cartridge.
2. Ensure that the device drivers for the tape backup unit are installed and are configured correctly. See
your tape drive documentation for more information about device drivers.
3. Reinstall the tape-backup software as instructed in the tape-backup software documentation.
4. Ensure that the interface cable of the tape drive is connected to the external port on the controller
card.
5. Perform the following steps to ensure that the controller card is properly installed:
a. Turn off the system and attached peripherals, and disconnect the system from the electrical
outlet.
b. Remove the system cover.
c. Reseat the controller card in the expansion card slot.
d. Install the system cover.
e. Turn on the system and attached peripherals.
6. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Next steps
If you cannot resolve the problem, see Getting Help.
Troubleshooting a hard drive
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
CAUTION: This troubleshooting procedure can erase data stored on the hard drive. Before you
proceed, back up all files on the hard drive.
Steps
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Depending on the results of the diagnostics test, proceed as needed through the following steps.
2. If your system has a RAID controller and your hard drives are configured in a RAID array, perform the
following steps:
a. Reboot the system and press <F10> during system startup to run the Lifecycle Controller, and
then run the Hardware Configuration wizard to check the RAID configuration.
See the Lifecycle Controller documentation or online help for information on RAID configuration.
b. Ensure that the hard drive(s) are configured correctly for the RAID array.
c. Take the hard drive offline and reseat the drive.
d. Exit the configuration utility and allow the system to boot to the operating system.
3. Ensure that the required device drivers for your controller card are installed and are configured
correctly. See the operating system documentation for more information.
4. Reboot the system and enter the System Setup.
5. Verify that the controller is enabled and the drives are displayed in the System Setup.
Next steps
If the problem persists, try troubleshooting the expansion cards or see Getting Help.
139
Troubleshooting a storage controller
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: When troubleshooting a SAS or PERC controller, see the documentation for your operating
system and the controller.
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Verify that the installed expansion cards are compliant with the expansion card installation
guidelines.
5. Ensure that each expansion card is firmly seated in its connector.
6. Install the system cover.
7. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
8. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
9. Remove the system cover.
10. Remove all expansion cards installed in the system.
11. Install the system cover.
12. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.
13. Run the appropriate diagnostic test. For more information, see Using System Diagnostics. If the tests
fail, see Getting Help.
14. For each expansion card you removed in step 10, perform the following steps:
a. Turn off the system and attached peripherals, and disconnect the system from the electrical
outlet.
b. Remove the system cover.
c. Reinstall one of the expansion cards.
d. Install the system cover.
e. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
If the tests fail, see Getting Help.
Troubleshooting expansion cards
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE: When troubleshooting an expansion card, see the documentation for your operating system
and the expansion card.
140
Steps
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Ensure that each expansion card is firmly seated in its connector.
5. Install the system cover.
6. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the
system from the electrical outlet.
7. Remove the system cover.
8. Remove all expansion cards installed in the system.
9. Install the system cover.
If the tests fail, see Getting Help.
10. For each expansion card you removed in step 8, perform the following steps:
a. Turn off the system and attached peripherals, and disconnect the system from the electrical
outlet.
b. Remove the system cover.
c. Reinstall one of the expansion cards.
d. Install the system cover.
e. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Next steps
If the problem persists, see Getting Help.
Troubleshooting processors
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Run the appropriate diagnostics test. See Using System Diagnostics for available diagnostic tests.
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
3. Remove the system cover.
4. Ensure that the processor and heat sink are properly installed.
5. Install the system cover.
6. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
Next steps
If the problem persists, see Getting Help.
141
System messages
For a list of event and error messages generated by the system firmware and agents that monitor system
components, see the Dell Event and Error Messages Reference Guide at dell.com/esmmanuals.
Warning messages
A warning message alerts you to a possible problem and prompts you to respond before the system
continues a task. For example, before you format a hard drive, a message warns you that you may lose all
data on the hard drive. Warning messages usually interrupt the task and require you to respond by typing
y (yes) or n (no).
NOTE: Warning messages are generated by either the application or the operating system. For more
information, see the documentation that accompanied the operating system or application.
Diagnostic messages
The system diagnostic utilities may issue messages if you run diagnostic tests on your system. See the
Using system diagnostics for more information about system diagnostics.
Alert messages
The systems management software generates alert messages for your system. Alert messages include
information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For
more information, see the systems management software documentation.
142
6
Using system diagnostics
If you experience a problem with your system, run the system diagnostics before contacting Dell for
technical assistance. The purpose of running system diagnostics is to test your system hardware without
requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service
and support personnel can use the diagnostics results to help you solve the problem.
Dell Embedded System Diagnostics
NOTE: The Dell Embedded System Diagnostics is also known as Enhanced Pre-boot System
Assessment (ePSA) diagnostics.
The embedded system diagnostics provides a set of options for particular device groups or devices
allowing you to:
• Run tests automatically or in an interactive mode
• Repeat tests
• Display or save test results
• Run thorough tests to introduce additional test options to provide extra information about the failed
device(s)
• View status messages that inform you if tests are completed successfully
• View error messages that inform you of problems encountered during testing
When to use the Embedded System Diagnostics
If a major component or device in the system does not operate properly, running the embedded system
diagnostics may indicate component failure.
Running the Embedded System Diagnostics from Boot Manager
1. As the system boots, press <F11>.
2. Use the up and down arrow keys to select System Utilities → Launch Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the
system. The diagnostics starts executing the tests on all the detected devices.
Running the Embedded System Diagnostics from the Dell Lifecycle
Controller
1. As the system boots, press <F11>.
2. Select Hardware Diagnostics → Run Hardware Diagnostics.
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the
system. The diagnostics starts executing the tests on all the detected devices.
143
System diagnostic controls
Menu Description
Configuration Displays the configuration and status information of all detected devices.
Results Displays the results of all tests that are executed.
System health Provides the current overview of the system performance.
Event log Displays a time-stamped log of the results of all tests run on the system. This is
displayed if at least one event description is recorded.
For information about embedded system diagnostics, see the ePSA Diagnostics Guide (Notebooks,
Desktops and Servers) at dell.com/support/manuals.
144
7
Jumpers and connectors
System board jumper settings
For information on resetting the password jumper to disable a password, see Disabling a forgotten
password.
Table 6. System board jumper settings
Jumper Setting Description
PWRD_EN
(default)
The password feature is enabled (pins 4–6).
The password feature is disabled (pins 2–4). iDRAC
local access is unlocked at the next AC power
cycle.
NVRAM_CLR
(default)
The configuration settings are retained at system
boot (pins 1–3).
The configuration settings are cleared at the next
system boot (pins 3–5).
145
System board connectors
Figure 59. System board connectors and jumpers
Item Connector Description
1. J_BP_SIG1 Backplane signal connector 1
2. J_PS2 PSU 2 power connector
3. J_BP_SIG0 Backplane signal connector 0
4 J_SATA_CD Optical drive SATA connector
5. J_SATA_TBU SATA tape backup unit connector
6. J_BP0 Backplane power connector
7. J_TBU Tape backup unit power connector
8 J_PS1 PSU 2 power connector
9. J_IDSDM Internal dual SD module connector
10. J_NDC Network daughter card connector
146
Item Connector Description
11 J_USB USB connector
12 J_VIDEO_REAR Video connector
13 J_COM1 Serial connector
14 J_IDRAC_RJ45 iDRAC7 connector
15 J_CYC System identification connector
16 CYC_ID System identification button
17 J_RISER_2AX Riser 2 connector
18 J_RISER_1AX Riser 1 connector
19 J_RISER_2BX Riser 2 connector
20 J_RISER_1BX Riser 1 connector
21 J_RISER_3AX Riser 3 connector
22 J_SATA_B SATA connector
23 J_QS Quick Sync connector
24 J_RISER_3BX Riser 3 connector
25 J_USB_INT Internal USB connector
26 J_STORAGE Storage controller card connector
27 J_SATA_A SATA connector
28 BAT Battery connector
29 CPU2 Processor socket 2
30 J_FAN1U_7 Cooling fan connector
31 B1, B5, B9, B2, B6, B10 Memory module sockets
32 J_BP3 Hard-drive backplane power connector
33 J_FAN1U_6 Cooling fan connector
34 J_BP_SIG2 Backplane signal connector 2
35 J_FAN1U_5 Cooling fan connector
36 J_BATT_SIG Battery signal connector
37 J_FAN1U_4 Cooling fan connector
38 A1, A5, A9, A2, A6, A10, B3, B7, B11, B4, B8,
B12
Memory module sockets
39 J_FAN1U_3 Cooling fan connector
40 J_FAN2U Cooling fan connector
41 J_FAN1U_2 Cooling fan connector
42 A12, A8, A4, A7, A11, A3 Memory module sockets
147
Item Connector Description
43 J_FAN1U_1 Cooling fan connector
44 J_CTRL_PNL Control panel connector
45 CPU1 Processor socket 1
46 J_FP_USB Front panel USB connector
Disabling a forgotten password
The system's software security features include a system password and a setup password. The password
jumper enables these password features or disables them and clears any password(s) currently in use.
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1. Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
2. Open the system.
3. Move the jumper on the system-board jumper from pins 4 and 6 to pins 2 and 4.
4. Close the system.
The existing passwords are not disabled (erased) until the system boots with the jumper on pins 2
and 4. However, before you assign a new system and/or setup password, you must move the jumper
back to pins 4 and 6.
NOTE: If you assign a new system and/or setup password with the jumper on pins 2 and 4, the
system disables the new password(s) the next time it boots.
5. Reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
6. Turn off the system, including any attached peripherals, and disconnect the system from the
electrical outlet.
7. Open the system.
8. Move the jumper on the system-board jumper from pins 2 and 4 to pins 4 and 6.
9. Close the system.
10. Reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
11. Assign a new system and/or setup password.
148
8
Technical specifications
Processor
Processor type One or two Intel Xeon processor E5-2600 v3
product family
Expansion Bus
Bus type PCI Express Generation 3
Expansion cards For a list of supported expansion cards, see
Expansion card installation guidelines.
Expansion slots using riser card:
Riser 1 (Slot 1) One half-height, three fourth-length x8
link
(Slot 2) One half-height, half-length x16 link
Riser 2 (Slot 1) One half-height, half-length x8 link or one
half-height, half-length x8 link
NOTE: Both processors must be installed to
use the slots on riser 1 and the x16 link on
riser 2.
(Slot 2) One half-height, half-length x8 link or one
half-height, half-length x16 link
Riser 3 (Slot 2) One half-height, half-length x8 link or one
half-height, half-length x16 link
Power
AC power supply (per power supply)
Wattage 495 W, 750 W, or 1100 W
Heat dissipation
NOTE: Heat dissipation is calculated using
the power supply wattage rating.
1908 BTU/hr maximum (495 W power supply)
2891 BTU/hr maximum (750 W power supply)
2843 BTU/hr maximum (750 W Titanium power
supply)
4100 BTU/hr maximum (1100 W power supply)
Voltage 100–240 V AC, autoranging, 50/60 Hz
or
149
Power
NOTE: This system is also designed to be
connected to IT power systems with a phase
to phase voltage not exceeding 230 V.
200–240 V AC, autoranging, 50/60 Hz, for 750 W
Titanium power supply
Memory
Architecture 1866 MT/ and 2133 MT/s registered Error
Correcting Code (ECC) DIMMs
Support for Advanced ECC or memory-optimized
operation
Support for LRDIMMs
Memory module sockets Twenty-four 288-pin
Memory module capacities
LRDIMM 4 GB, 8 GB, 16 GB, or 32 GB single-, dual-, or
quad-ranked
RDIMM 4 GB, 8 GB, or 32 GB single-, dual-, or quad-
ranked
16 GB single- or dual-ranked
Minimum RAM 2 GB with a single processor
4 GB with two processors
Maximum RAM
LRDIMM Up to 768 GB
RDIMM Up to 512 GB
Drives
Hard drives
8–hard-drive systems Up to eight 2.5 inch, internal, hot-swappable SAS,
SATA, or Nearline SAS hard drives
10–hard-drive systems Up to ten 2.5 inch, internal, hot-swappable SAS,
SATA, or Nearline SAS hard drives
24–hard-drive systems Up to 24 1.8 inch, internal, hot-swappable SAS,
SATA, or Nearline SAS hard drives
Optical drive
(8 hard-drive systems only)
One optional SATA DVD-ROM drive or DVD+/-
RW drive
NOTE: DVD devices are data only.
150
Connectors
Back
NIC Four 10/100/1000 Mbps or two 10/100/1000
Mbps and two 100 Mbps/1 Gbps/10 Gbps
Serial DB-9 Serial Port connector
USB Two 4-pin, USB 3.0-compliant
Video 15-pin VGA
Front
8 hard-drive systems
USB Two 4-pin, USB 3.0-compliant
Video 15-pin VGA
External vFlash card vFlash memory card slot
NOTE: The card slot is available for use only if
the iDRAC8 Enterprise license is installed on
your system.
10 hard-drive systems
USB One mini USB 3.0-compliant
Internal
USB One 4-pin, USB 3.0-compliant
Internal Dual SD Module (IDSDM) Two optional flash memory card slots with the
internal SD module
NOTE: One card slot is dedicated for
redundancy.
Video
Video type Integrated VGA controller
Video memory 16 MB shared
Expanded Operating Temperature
NOTE: When operating in the expanded temperature range, system performance may be impacted.
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be
reported on the LCD and in the System Event Log.
< 10% of annual operating hours Continuous Operation 5°C to 40°C at 5% to 85%
RH with 29°C dew point.
151
Expanded Operating Temperature
NOTE: Outside the standard operating
temperature (10°C to 35°C), the system can
operate continuously down to 5°C or as high
as 40°C.
For temperatures between 35°C and 40°C, de-
rate maximum allowable temperature by 1°C per
175 m above 950 m (1°F per 319 ft).
< 1% of annual operating hours –5°C to 45°C at 5% to 90% RH with 29°C (84.2°F)
maximum dew point.
NOTE: Outside the standard operating
temperature (10°C to 35°C), the system can
operate down to –5°C or up to 45°C for a
maximum of 1% of its annual operating hours.
For temperatures between 40 °C and 45 °C, de-
rate maximum allowable dry bulb temperature by
1°C per 125 m above 950 m (1°F per 228 ft).
Expanded Operating Temperature Restrictions • Do not perform a cold startup below 5°C.
• The operating temperature specified is for a
maximum altitude of 3048 m (10,000 ft).
• PCIe SSD and 1.8 inch SSDs are not supported.
• GPU is not supported.
• 145 W and Workstation CPU (160 W)
processors are not supported.
• Two power supply units are required and one
power supply unit failure is not supported.
• Non Dell qualified peripheral cards and/or
peripheral cards greater than 25 W are not
supported.
Environmental
NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.
Temperature
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Storage temperature limits –40°C to 65°C (–40°F to 149°F)
Relative humidity
Storage 5% to 95% RH with 33°C (91 °F) maximum dew
point. Atmosphere must be non-condensing at
all times.
Temperature (continuous operation)
152
Environmental
Temperature ranges (for altitude less than 950 m
or 3117 ft)
10°C to 35°C (50°F to 95°F) with no direct
sunlight on the equipment.
Humidity percentage range 10% to 80% Relative Humidity with 26°C
(78.8°F) maximum dew point.
Maximum vibration
Operating 0.26 Grms at 5 Hz to 350 Hz (all operation
orientations).
Storage 1.87 Grms at 10 Hz to 500 Hz for 15 min (all six
sides tested).
Maximum shock
Operating One shock pulse in the positive z axis of 31 G
for 2.6 ms in all operational orientations.
Storage Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2
ms.
Maximum altitude
Operating 3,048 m (10,000 ft)
Storage 12,000 m (39,370 ft).
Operating altitude de-rating
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300
m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m
(1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m
(1°F/228 ft) above 950 m (3,117 ft).
Particulate contamination
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from
particulates and gaseous contamination. If it is determined that levels of particulates or gaseous
pollution are beyond the limits specified below and are the reason for the damage and/or failures
to your equipment, it may be necessary for you to re-mediate the environmental conditions that
are causing the damage and/or failures. Re-mediation of environmental conditions will be the
responsibility of the customer.
Air filtration Data center air filtration as defined by ISO Class
8 per ISO 14644-1 with a 95% upper confidence
limit.
NOTE: Air entering the data center must
have MERV11 or MERV13 filtration.
153
Environmental
NOTE: Applies to data center environments
only. Air filtration requirements do not apply
to IT equipment designed to be used outside
a data center, in environments such as an
office or factory floor.
Conductive dust
NOTE: Applies to data center and non-data
center environments.
Air must be free of conductive dust, zinc
whiskers, or other conductive particles.
Corrosive dust
NOTE: Applies to data center and non-data
center environments.
• Air must be free of corrosive dust.
• Residual dust present in the air must have a
deliquescent point less than 60% relative
humidity.
Gaseous contamination
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
Copper coupon corrosion rate <300 Å/month per Class G1 as defined by ANSI/
ISA71.04-1985.
Silver coupon corrosion rate <200 Å/month as defined by AHSRAE TC9.9.
154
9
Getting help
Contacting Dell
About this task
NOTE: Dell provides several online and telephone-based support and service options. If you do not
have an active Internet connection, you can find contact information on your purchase invoice,
packing slip, bill, or Dell product catalog. Availability varies by country and product, and some
services may not be available in your area.
To contact Dell for sales, technical support, or customer-service issues:
Steps
1. Go to dell.com/support.
2. Select your country from the drop-down menu on the top left corner of the page.
3. For customized support:
a. Enter your system service tag in the Enter your Service Tag field.
b. Click Submit.
The support page that lists the various support categories is displayed.
4. For general support:
a. Select your product category.
b. Select your product segment.
c. Select your product.
The support page that lists the various support categories is displayed.
Locating your system service tag
Your system is identified by a unique Express Service Code and Service Tag number. The Express Service
Code and Service Tag are found on the front of the system by pulling out the information tag.
Alternatively, the information may be on a sticker on the chassis of the system. This information is used
by Dell to route support calls to the appropriate personnel.
Documentation feedback
If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you
can click on the Feedback link in any of the Dell documentation pages, fill out the form, and click Submit
to send your feedback.
Quick Resource Locator
Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to
videos. This can be done by visiting dell.com/QRL or by using your smartphone or tablet and a model
155
specific Quick Resource (QR) code located on your Dell PowerEdge system. To try out the QR code, scan
the following image.
156