Fujitsu ASYG07KGTA User Manual
Displayed below is the user manual for ASYG07KGTA by Fujitsu which is a product in the Split-System Air Conditioners category. This manual has pages.
Related Manuals
En-1
AIR CONDITIONER
Wall Mounted Type
OPERATING MANUAL
Before using this product, read these instructions thoroughly and keep this manual for future reference.
Safety Precautions
To prevent personal injury, or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classied as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED. This mark denotes an action that is COMPULSORY.
• Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant is leaked and exposed to an external
ignition source, there is a risk of re.
CAUTION This symbol shows that the operation manual should be read carefully.
CAUTION This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
CAUTION This symbol shows that information is available such as the operating manual or installation manual.
WARNING
• This product contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
• In the event of refrigerant leakage, be sure to keep away
from re or any ammables, and consult authorized service
personnel.
• In the event of a thunder storm or any prior sign of a lightning
strike, turn off the air conditioner via the remote controller,
and refrain from touching the product or the power source to
prevent any electrical hazards.
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
• The appliance shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical
damage from occurring.
• Disposing of the product shall be done properly, in
compliance with national or regional regulations.
• During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
ammable gas to leak during operation).
• This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
• Do not start or stop the operation of this product by inserting or
pulling out the power plug, or by turning on or off the circuit breaker.
• Do not use ammable gases near this product.
• Do not expose yourself directly to the cooling airow for
many hours.
• Do not insert your ngers or any other objects into outlet
port, open panel, or intake grille.
• Do not operate with wet hands.
• Do not install the unit in area lled with mineral oil such as a
factory or area containing a large amount of splashed oil or
steam such as a kitchen.
• Do not use means to accelerate the defrosting process or to
clean the appliance, other than those recommended by the
manufacturer.
• Do not pierce or burn.
Contents
Safety Precautions ............................................................... 1
Indoor Unit Overview and Operations .................................. 3
Remote Controller Overview and Operations ....................... 4
Timer Operation.................................................................... 6
Human Sensor (Energy Saving) ........................................... 8
General Information on Operation ........................................ 9
Cleaning and Care.............................................................. 10
Troubleshooting .................................................................. 12
PART No. 9387602005-02 [Original instructions]
EnglishDeutschFrançaisEspañolItalianoEλληvIkάPortuguêsРусскийTürkçe
9387602005-02_OM.indb 1 25/01/2019 13:22:38
En-2 OPERATING MANUAL
Indoor unit accessories
Remote
controller
Batteries Air cleaning lters Filter holders
Remote controller
holder
Tapping screws
Remote controller holder installation
321
Screws
Insert
Slide up
WARNING
Take care to prevent infants and young children from acciden-
tally swallowing the batteries.
CAUTION
• Do not attempt to recharge dry batteries.
• Do not use dry batteries that has been recharged.
Battery (R03/LR03/AAA × 2) loading and remote controller preparation
4
2
3
16
7
8
5
9
5 Press the "CLOCK ADJUST" button to start clock setting.
6 Set the day of the week by pressing "SELECT" button (Monday
to Sunday). *By pressing the "TEMP." ( / ) buttons, the time
indicator can be changed from a 24-hour to a 12-hour clock.
7 Press "NEXT" button to continue.
8 Set the time by pressing "SELECT" button.
Pressing or changes the value by the minute.
Pressing down on or changes the value by 10 minutes.
9 To complete, press the "SEND" button close to the indoor unit.
Settings may not be properly sent if pressed from a distance.
NOTES:
• Use specied type of batteries only.
• Do not mix different types or new and used batteries together.
• Batteries can be used about 1 year in ordinary use.
• If the remote control range noticeably shortens, replace the batter-
ies, and press the "RESET" button as shown in page 5.
CAUTION
• Provide occasional ventilation during use.
• Always operate the unit with air lters installed.
• Ensure that any electronic equipment is at least 1 m (40 in)
away from either the indoor unit or outdoor unit.
• Disconnect all the power supply when you are not using this
product for extended periods.
• After a long period of use, ensure to get the mounting of the
indoor unit checked to prevent this product from falling down.
• The airow direction and the room temperature should be
carefully considered when you use this product in a room
with infants, children, elderly or sick persons.
• Do not place any other electrical products or household
belongings under this product.
Dripping condensation from this product might get them wet,
and may cause damage or malfunction of your property.
• Do not expose this product directly to water.
• Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects. This
may cause quality deterioration of those items.
• Do not expose animals or plants to the direct airow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable to disconnect the plug.
• Do not touch the aluminum ns of heat exchanger built-in
this product to avoid personal injury when you maintain the
unit.
• Do not stand on unstable steps when operating or cleaning
this product. It may overturn and can cause injury.
• Do not direct the airow at replaces or heating apparatus.
• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator ns.
• Do not climb on, place objects on, or hang objects from this
product.
This product contains uorinated greenhouse gases.
9387602005-02_OM.indb 2 25/01/2019 13:22:41
En-3
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
1 Intake grille
Before starting operation, make sure that the intake grille has been
shut completely. Incomplete closing may have an effect on the proper
function or performance of the product.
2 "MANUAL AUTO" button
Use when the remote controller is lost or there is a malfunction.
Status Action Mode or operation
In operation Press more than 3 seconds. Stop
Stopping Press more than 3 seconds and
less than 10 seconds. Auto
Press more than 10 seconds.
(Only for servicing.*) Forced cooling
After cleaning Press less than 3 seconds. Filter indicator reset
*:To stop the Forced cooling, press this button or Start/Stop button on
the remote controller.
3 Front panel
See page 8
4 Human Sensor
Used for Energy Saving Function. Controls temperature setting by
detecting people in the room.
5 Vertical airow direction louver
Each time you press the "SET" button on the remote controller, the
angle of the vertical airow direction louver moves as follows:
1
2
3
4
56
Cooling or Dry
mode Heating mode
1 2 365
* *
4
*: Default setting in each mode.
• Do not adjust by hand.
• At the beginning of Auto or Heating mode, they may stay on position
1 for a while for adjustment.
• If the angle is set to position 4-6 for more than 30 minutes in Cooling
or Dry mode, the louver will automatically return to position 3.
• Keeping the position 4-6 during Cooling or Dry mode may cause
condensation to form, and the drops may damage your property.
6 Drain hose
7 Remote controller signal receiver
CAUTION
For appropriate signal transmission between remote controller
and indoor unit, keep the signal receiver away from the follow-
ing items:
- Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous uorescent lights, such as
inverter type ones, the signal may not be transmitted properly.
In such a case, consult the store of purchase.
6
9
8
10
13
1
2
3
4
4
4
5
7
12
11
8
Economy indicator (green)
Lights in the Economy operation and in the 10 °C Heat operation.
9
Timer indicator (orange)
Lights in the Timer operation, and blinks slowly when the timer setting
error is detected.
For details, refer to “Auto-restart function” on page 9.
10 Operation indicator (green)
Lights in the normal operation, and blinks slowly in the Automatic
defrosting operation.
11
Horizontal airow direction louvers
CAUTION
Before you adjust the horizontal airow direction, make sure
that the vertical airow direction louver has been stopped
completely.
Adjust two knobs by hand.
See page 10
12
Air lter
See page 11
13
Air cleaning lters
Purify or deodorize the air, and provide fresh airow.
Indoor Unit Overview and Operations
9387602005-02_OM.indb 3 25/01/2019 13:22:42
En-4 OPERATING MANUAL
CAUTION
• To prevent malfunction or damage of the remote controller:
- Place remote controller at where will not be exposed to
direct sunlight or excessive heat.
- Remove batteries if the product is not going to be used for
an extended period.
- Exhausted batteries must be removed immediately, and
be disposed according to the local laws and regulations of
your region.
• If leaking battery uid comes in contact with your skin, eyes,
or mouth, immediately rinse with plenty of clean water, and
consult your physician.
• Obstacles such as a curtain or wall between the remote
controller and the indoor unit may affect the appropriate
signal transmission.
• Do not apply strong shocks to the remote controller.
• Do not pour water on the remote controller.
Remote Controller Overview and Operations
22
19
20
18
23
2
10
15
14
21
3
1
5
6
7
8
9
12
11
16
13
4
24
17
You can quickly start operation with the following 3 steps:
1 Start/Stop button
2 "MODE" button
Switches operation mode in following order.
AUTO COOL DRY FAN HEAT
Notes in the Heating mode:
• At the beginning of the operation, the indoor unit operates at very
low fan speed for about 3–5 minutes for preparation, then switches
to the selected fan speed.
• The Automatic defrosting operation overrides the heating operation
when necessary.
Note in the Cooling mode:
Indoor unit fan may stop from time to time to perform Indoor unit fan
control for energy saving that enables power-saving operation by
stopping the rotation of the indoor unit fan when the outdoor unit is
stopped.
3 "TEMP." (temperature) buttons
Sets the desired temperature.
The temperature can be set in 0.5°C increments.
In the Cooling or Dry mode, the temperature needs to be set lower
than the current room temperature. In the Heating mode, the
temperature needs to be set higher than the current room temperature.
Otherwise, corresponding operation mode may not start.
Temperature setting range
Auto/Cooling/Dry 18.0–30.0 °C
Heating 16.0–30.0 °C
NOTES: Temperature control is not available in the Fan mode.
4 Remote controller display
In this section, all the possible indicators are displayed for description.
In actual operation, the display is linked with the button operation, and
only shows the necessary indicators for each setting.
5 "POWERFUL" button
Activates the Powerful operation.
The unit will operate at maximum power and strong air ow to quickly
cool down or warm up the room.
When activated, the indoor unit will emit 2 short beeps.
To turn off, press the "POWERFUL" button again. The indoor unit will
then emit 1 short beep.
The Powerful operation is automatically turned off in the following
situations:
• Adjusted room temperature reaches the set temperature in Cooling,
Dry, or Heating mode.
• 20 minutes have passed after the Powerful operation mode has
been set.
Even in situations above, the Powerful operation will not automatically
turn off unless it has run for a certain amount of time.
NOTES:
• The air ow direction and the fan speed are controlled automatically.
• This operation cannot be performed simultaneously with the
Economy operation.
• The Powerful operation will override the Outdoor Unit Low Noise or
Energy Saving functions. These functions, if set, will start after the
Powerful operation is turned off.
6 "10 °C HEAT" button
Starts the 10 °C Heat operation that maintains the room temperature
at 10 °C so as to prevent the room temperature to drop too low.
After pressing the button to start the 10 °C Heat operation, the indoor
unit emits 2 short beeps and the Economy indicator (green) will turn
on.
To turn off, press the Start/Stop button. The Economy indicator will
turn off.
NOTES:
• In the 10 °C Heat operation mode, only the vertical air ow direction
can be adjusted by using the "SET" button.
• The Heating mode will not be performed if the room temperature is
warm enough.
(continued)
9387602005-02_OM.indb 4 25/01/2019 13:22:43
En-5
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
Remote Controller Overview and Operations (continued)
7 Signal transmitter
Aim at the signal receiver of the indoor unit properly.
• Signal transmit indicator on the remote controller display shows
that the signal from the remote controller is being transmitted.
• Operating range is approximately 7 m.
• You will hear a beep if the transmitted signal has been sent properly.
If there is no beep, press the button on the remote controller again.
8 "FAN" button
Controls the fan speed.
(Auto) (High) (Med) (Low) (Quiet)
• When "AUTO" is selected, the fan speed is automatically adjusted
according to the operation mode.
9 "SWING" button
Starts or stops automatic swing of the vertical airow direction louver.
• Each time you press the button, the vertical airow direction louver
swings as follows:
Cooling, Dry, or Fan
mode Heating or Fan mode
1 2 34
36
5
4
1
2
3
4
56
NOTES:
• The Swing operation may stop temporarily when the fan in the unit
is rotating at very low speed or stopping.
• In the Fan mode, either of swing direction 1 ↔ 4 or 3 ↔ 6 is
performed in accordance with the vertical airow direction previously
set before you start the Swing operation.
See page 3
10
"SET" button
Adjusts the vertical airow direction.
See page 7
11
"WEEKLY" timer button
Activates the Weekly timer for a maximum of 4 on or off programs per
day, each day of the week.
See page 6
12
"SLEEP" timer button
Activates the Sleep timer that helps you to fall asleep comfortably with
gradual temperature control.
See page 6
13
"ON/OFF" timer button
Activates the On/Off timer.
14
"NEXT" button
Used for adjusting the timer setting.
15
"BACK" button
Used for adjusting the timer setting.
16
"RESET" button
When you press the "RESET" button, press it gently by using the tip
of a ballpoint pen or other small object in correct direction as shown in
this gure.
RESET
17
“TEST RUN” button
Only used for the initial test in the unit installation.
Do not press this button under normal use because it will cause
incorrect operation.
• During the test run, the Operation indicator and the Timer indicator
blink simultaneously.
• To quit the test run that is started unintentionally, you need to turn
off the air conditioner by pressing the Start/Stop button.
See page 2
18
"CLOCK ADJUST" button
Used for adjusting the clock.
19
"SEND" button
Used for sending the clock or timer setting.
See page 6
20
"TIMER SETTING" button
Used to enter the timer setting mode.
21
"SELECT" button
Used for adjusting the clock or timer.
22
"OUTDOOR UNIT LOW NOISE" button
Starts or stops the Outdoor Unit Low Noise operation that lowers
noise generated from the outdoor unit by cutting down the rotation
number of the compressor, and suppressing the fan speed.
Once the operation is set, the setting is preserved until you press this
button again to stop the operation, even if the indoor unit operation is
stopped.
"LOW NOISE" indicator on the remote controller display shows that
the unit is in the Outdoor Unit Low Noise mode.
NOTES:
• This operation cannot be performed simultaneously with the Fan,
Dry and Powerful operation modes.
23
"ECONOMY" button
Starts or stops the Economy operation that saves more electricity
than other operation modes by changing the set temperature to a
moderate setting.
By pressing the "ECONOMY" button, the Economy indicator on the
indoor unit turns on.
• In the Cooling or Dry mode, the room temperature will be adjusted a
few degrees higher than the set temperature.
• In the Heating mode, the room temperature will be adjusted a few
degrees lower than the set temperature.
NOTES:
• In the Cooling, Heating, or Dry mode, the maximum output of this
operation is approximately 70 % of usual air conditioning operation.
• This operation cannot be performed during temperature monitoring
by the Auto mode.
See page 8
24
"SENSOR" button (ENERGY SAVING PROGRAM)
Activates or deactivates the energy saving function.
* The Energy Saving function is On at the time of purchase.
: The setting must be done while the setting screen is displayed for
each function.
: The button is controllable only when the air conditioner is on.
9387602005-02_OM.indb 5 25/01/2019 13:22:45
En-6 OPERATING MANUAL
Timer Operation
(continued)
Remote Controller Overview and Operations (continued)
1
Press the Start/Stop button until only the clock is
displayed on the remote controller display.
2 Press the “MODE” button for at least 5 seconds to
display the current custom code (initially set to A).
3 Press the “TEMP." (∧/∨) buttons to change the
custom code between A↔B↔C↔D. Match the
code on the display to the air conditioner custom code.
4 Press the “MODE” button again to return to the clock display.
The custom code will be changed.
If no buttons are pressed within 30 seconds after the
custom code is displayed, the system returns to the
original clock display. In this case, start again from step 1.
The air conditioner custom code is set to “A” prior to ship-
ment. Contact your retailer to change the custom code.
Depending on the remote controller, the custom code may
return to custom code A when the batteries are replaced.
In this case, if you use a code other than A, reset the code
after replacing the batteries. If you do not know the air
conditioner custom code setting, try each of the custom
codes (A→B→C→D) until you nd the code which oper-
ates the air conditioner.
To set the program timer, conduct the same steps 1 to 5 for the On/
Off timer. (Select On⇔Off in Step 2)
NOTES:
• If you change the setting value for the timer after the Program timer
is set, the counting down of the timer will be reset at that moment.
• Time setting for each combination should be within a span of 24 hours
.
Sleep timer
To set the Sleep timer, rst follow steps 1 to 3 for the On/Off timer.
4 Adjust the time by pressing the "SELECT" button while the
"CLOCK" indicator is blinking.
Each time you press the button, the time changes as follows:
9H
00M
7H
00M
5H
00M
3H
00M
2H
00M
1H
00M
0H
30M
hours
(30 min.)
5 Press the "SEND" button.
To cancel the Sleep timer, press the "SLEEP" button while the
"SLEEP" indicator is on. (Erases the indicator)
To help you to fall asleep comfortably and prevent excessive warming
or cooling in sleep, the Sleep timer controls the temperature setting
automatically in accordance with the set time shown as follows. The
air conditioner completely turns off after the set time has elapsed.
In Heating mode
Set
temperature
Set time
1 hour
Set time
1 hour
1.5 hour
30 min.
1 °C 2 °C 3 °C 4 °C
2 °C
1 °C
In Cooling or Dry mode
Fan control for energy saving
When the set temperature is reached during
The Cooling operation, the fan operates
intermittently and power is saved.
Fan control for energy saving function is On at
the time of purchase.
To use this function, use the following steps;
1. Turn off the indoor unit by pressing the Start/
Stop button.
2. Press the "FAN" button for at least 5 seconds
until the current Fan Control “FC” status is
displayed.
3. Press the "TEMP." (∧/∨) buttons to switch between "ON" or "OFF".
4. Press the Start/Stop button to send the setting to the indoor unit. After
the status is sent, the display will automatically return to the original
screen.
If no buttons are pressed within 30 seconds after the “FC” status is
displayed, the system returns to the original clock display. In this case,
start again from step 1.
Remote controller custom code setting
When two or more air conditioners are installed in a room and the
remote controller is operating an air conditioner other than the one you
wish to set, change the custom code of the remote controller to operate
only the air conditioner you wish to set (4 selections possible).
When two or more air conditioners are installed in a room, please
contact your retailer to set the individual air conditioner custom codes.
Use the following steps to select the custom code of the remote
controller. (Note that the air conditioner cannot receive a signal if it has
not been set for the matching custom code.)
Note for timer settings:
Any interruption of the power supply, such as a blackout or cutting off of a circuit breaker, makes the set internal clock go wrong.
In such a case, the Timer indicator on the indoor unit blinks, and you need to readjust the setting.
On timer or Off timer
You can set the On timer or Off timer with the following steps.
1 Press the "TIMER SETTING" button to start the setting.
The "WEEKLY" indicator on the remote controller will be blinking.
2 Press the "SELECT" button to choose the desired mode. The
mode will change as follows:
WEEKLY ON/OFF
(On) ON/OFF
(Off) ON/OFF
(On
⇔
Off) SLEEP
(Off)
3 Press the "NEXT" button. Continue to setting for each mode.
* To cancel timer setting during the setting process, press the
"TIMER SETTING" button again.
4 Adjust the time by pressing the "SELECT" button while the
"CLOCK" indicator is blinking. Each time you press the button,
the time will change by +5/-5 minutes. Pressing down will change
the time by +10/-10 minutes.
5 Press the "SEND" button.
To redo the timer setting, perform the steps 1 to 5 again.
To cancel the On/Off timer, press the "ON/OFF" button while the "ON/
OFF" indicator is on. (Erases the indicator)
Program timer (combined use of the On timer and the Off timer)
You can set an integrated On→Off or Off→On timer.
Either of the timer whose congured starting time is closer to the
current time works rst, and the order of the timer operation is
displayed as follows:
Timer Indicator on remote controller display
On→Off timer
Off→On timer
9387602005-02_OM.indb 6 25/01/2019 13:22:45
En-7
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
Timer Operation (continued)
Weekly timer
On and Off timer can be combined, and up to 4 reservations (program
) per day and 28 reservations per week.
Before setting the program, please set the week and time of the air con-
ditioner rst.
If the week and time are not set, the weekly timer will not operate cor-
rectly at the set time.
Please refer to "remote controller preparation" (page 2).
Example of Weekly timer 1
No timer settings
Program
9:00 Off
Program
11:00 Off
Program
17:00 Off
Program
23:00 Off
Monday to
Friday
Saturday
Sunday
Program
7:00 On 26°C
Program
9:00 Off
Wake up Leave for work
Program
17:00 On 28°C
Program
23:00 Off
Come back home Go to sleep
On On On On
Example of Weekly timer 2
You can specify a given temperature in the On setting in Weekly timer.
Program
7:00 On 28°C
Program
9:00 On 26°C
Program
17:00 On 27°C
Program
23:00 On 28°C
* You can set the temperature for the Auto, Cooling, or Dry mode within
the range of 18-30°C, for the Heating mode the range is 10 or 16-30°C.
Even if you set to 10, 16, or 17°C, if you run the product on the Auto,
Cooling, or Dry mode, it will run at 18°C.
NOTES:
●
Operations modes other than the temperature setting will be the
same at the last time operation was stopped, so Cooling → Heating
→ Cooling → Heating type of operations cannot be automatically set.
● If you set the On timer and Off timer on the same time, the air con-
ditioner will run the On timer. If two On timer are set at the same
time, the air conditioner will run in the order of the program number.
● If there is a power interruption, such as due to a power outage
during the Weekly timer setting or a circuit breaker cutting out, the
internal timer of the air conditioner will be incorrect. (See page
9 "Auto-restart function".) In such a case, the main timer lamp
will notify you of this by blinking, so carry out matching of the time
and date. (See page 2 "remote controller preparation".)
● You cannot use the Weekly timer together with the other timers.
If you want to run the product on Weekly timer after using the On/
Off timer, Program timer, or Sleep timer while the Weekly timer is
running, you need to activate the Weekly timer again.
To set the Weekly timer, first follow steps 1 to 3 on page 6
for the On/Off timer.
4 Select the program number and the day using the "SELECT"
button.
Program 1Week Program Monday Program Tuesday Program Sunday
Program 1Week Program Monday Program Saturday Program Sunday
Press the "NEXT" button, when the program number and day you
want to set are blinking.
5 Press the "SELECT" button to select the operation mode (On
timer, Off timer, or No timer operation).
To operate without a timer
1. Press the "NEXT" button to go back to step 4 and con gure
the next setting.
2. Press the "SEND" button to nish.
Press the "NEXT" button.
6 Press the "SELECT" button to set the desired On time or Off
time.
If you selected Off in step 5
1. Press the "NEXT" button to go back to step 4 and con gure
the next setting.
2. Press the "SEND" button.
Press the "NEXT" button.
7 Press the "SELECT" button to set the temperature.
If you want to move on to the next setting, press the "NEXT"
button, return to step 4 and con gure the next setting.
8 To complete the setting, press the "SEND" button.
If you want to cancel the setting midway, please press the
"TIMER SETTING" button instead of pressing the "SEND"
button.
NOTES:
● When canceling the Weekly timer, select the No timer operation in
Step 5 in the Weekly timer setting.
● If you want to go back to the previous step when con guring set-
tings, press the "BACK" button.
● Press the "SEND" button, when you are close to the main unit. If
you do so when far from the main unit, the signal may not get prop-
erly sent, and the settings may not get properly con gured.
● To check the schedule, repeat steps 1 to 3 to enter the Weekly
timer mode, then use the "SELECT" button to browse through the
Weekly timer settings in the order shown in step 4.
● To cancel the Weekly timer, press the "WEEKLY" timer button while
the "WEEKLY" indicator is on. (The indicator will turn off)
9387602005-02_OM.indb 7 25/01/2019 13:22:48
En-8 OPERATING MANUAL
Human Sensor (Energy Saving)
To prevent waste of electricity, this function controls the temperature
setting when no one is occupying the room. Energy Saving function is
on at the time of purchase.
1 To activate the Energy Saving function, press the "SENSOR"
button.
"ENERGY SAVING" indicator on the remote controller will blink.
2 To deactivate the Energy Saving function, press the "SENSOR"
button again.
"ENERGY SAVING" indicator on the remote controller will turn
off.
About the Energy Saving Function
If no one enters the room for approximately 20 minutes, the set
temperature will be automatically controlled.
(When someone comes back into the room, the human sensor will
detect this, and automatically revert to the original settings.)
Operation
mode
Operating details
(if there is no one in the room for a while)
Cooling/Dry The set temperature will be increased by a maximum of
approximately 2˚C.
Heating The set temperature will be decreased by a maximum
of approximately 4˚C.
Auto This runs the Energy Saving function automatically for
the selected mode (Cooling/ Heating/ Dry).
● When using together with the Sleep timer (page 6), the Sleep
timer will be prioritized.
● During the 10°C Heat operation, if there is no one in the room the
set temperature will not be changed.
● Application range is as follows.
Vertical angle 90° (Side view) Horizontal angle 100° (Top view)
6 m
6 m 90° 50° 50°
Energy Saving function may not work when the room temperature is
very different from the temperature dened in temperature setting, such
as when immediately after starting the operation.
About the HUMAN SENSOR
Details about detection with the human sensor
● The human sensor detects whether there are people in the room
by looking for movement by people in the room.
Since the human sensor detects infrared light given out by
people, there may be cases where this detection is incorrect.
Situations in which the sensor will detect no people in the
room, even when there is someone there
When the temperature is high and the difference with be-
tween people’s body temperature is small.
(Such as during the summer when the temperature is 30°C
or higher.)
When there is someone in the room, but they do not move
for a long period of time.
When someone is hidden behind a sofa, other furniture,
glass, or in similar situations.
When someone is wearing extremely thick clothing and has
their back facing the sensor.
Situations in which the sensor will incorrectly detect people
in the room, even when there is no one there
When there is a dog or a cat moving around in the room.
When the wind is making curtains or plants move.
When there are heating units, humidiers, or electric appli-
ances such as oscillating electric fans operating.
NOTES
9387602005-02_OM.indb 8 25/01/2019 13:22:48
En-9
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
General Information on Operation
Automatic defrosting operation
When outdoor temperature is very low with high humidity, frost
may form on the outdoor unit during the Heating operation, and
it could reduce the operating performance of the product.
For frost protection, a microcomputer-controlled automatic
defrost function is equipped in this air conditioner.
If frost forms, the air conditioner will temporarily stop, and
defrost circuit will operate briey (maximum of 15 minutes.)
The Operation indicator on the indoor unit blinks during this
operation.
If frost forms on the outdoor unit after the Heating operation,
the outdoor unit will stop automatically after it operates for a few
minutes. Then the Automatic defrosting operation starts.
Auto-restart function
In event of power interruption such as a blackout, the air
conditioner stops once. But it restarts automatically and
performs previous operation when the power supply is resumed.
If any power interruption occurs after the timer is set, counting
down of the timer will be reset.
After the power supply is resumed, the Timer indicator on the
indoor unit blinks to notify you that there has been a timer fault.
In such a case, reset the timer for your opportune time.
Heating performance
This air conditioner operates on the heat-pump principle,
absorbing heat from air outdoors and transferring that heat
to the indoor unit. As a result, the operating performance is
reduced as outdoor air temperature drops. If you feel that the
heating performance is insufcient, we recommend you to use
this air conditioner in conjunction with other kinds of heating
appliance.
Group Control (optional)
One remote controller can control up to 16 air conditioners.
All of the air conditioners will be operated with the same
settings.
Malfunctions caused by other electrical devices:
Use of other electrical appliances such as an electric shaver or
nearby use of a wireless radio transmitter may cause the malfunction
of the air conditioner.
If you encounter such a malfunction, turn off the circuit breaker once.
Then turn it on again, and resume operation by using the remote
controller.
Wired remote controller (option)
The optional wired remote controller can be used.
When you use remote controller, there are following different points
as compared with using wireless remote controller.
[The additional functions for wired remote controller]
• Temperature set back timer
You can use both wired and wireless remote controller
simultaneously. (But function is limited.)
When the restricted functions on the remote controller are used, a
beeping sound will be heard, and the Operation, Timer, and Economy
indicators of the indoor unit will blink.
[The restricted functions for wireless remote controller]
<Wired remote controller (Non-polar 2-wired)>
• Outdoor unit low noise
• 10°C Heat
• Weekly timer
• Powerful
Wireless LAN control (option)
The optional wireless LAN control can be used.
9387602005-02_OM.indb 9 25/01/2019 13:22:48
En-10 OPERATING MANUAL
Cleaning and Care
CAUTION
• Before cleaning this product, be sure to turn it off and disconnect all the power supply.
• Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an
effect on the proper working or performance of the air conditioner.
• Do not touch the aluminum ns of heat exchanger built-in the indoor unit to avoid personal injury when you maintain the unit.
• Do not expose the indoor unit to liquid insecticides or hair sprays.
• Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.
Daily care
When cleaning the indoor unit body, mind the following:
• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or
thinner.
• Wipe the unit gently by using a soft cloth.
Cleaning the intake grille
1 Hold the intake grille with both hands at side, then pull to the front
until it becomes hooked. Keeping the intake grille in a horizontal
position, pull the mounting shaft on the left and right to release.
Mounting
shaft
Intake grille
Mounting
shaft
2 Wash the intake grille gently with water or wipe it gently with a
soft cloth moisten with warm water.
Then wipe it with a dry and soft cloth.
3 Attach the left and right mounting shaft in the direction of the
arrow to the panel top bearing while supporting the intake grille
horizontally. Press this until it clicks so that each shaft snaps into
place.
Mounting
shaft
Mounting
shaft
Intake grille
Bearing
Bearing
4 Press 4 places on the intake grille to close it completely.
Cleaning the air lters
1 Open the intake grille, and remove the air lters.
Lift up the air lter’s handle, disconnect the two hooks, and pull
out.
Air Filter handle
Hooks (2 places)
2 Remove dust with a vacuum cleaner or by washing.
After washing, allow to dry thoroughly in a shaded place.
3 Replace the air lter and close the intake grille.
(1) Align the sides of the air lter with the panel, and push in fully,
making sure the two hooks are returned properly to their holes
in the panel.
Hooks (2 places)
(2) Close the intake grille.
• Dust can be cleaned from the air lter either with a vacuum cleaner,
or by washing the lter in a solution of mild detergent and warm
water. If you wash the lter, be sure to allow it to dry thoroughly in a
shady place before reinstalling.
• If dirt is allowed to accumulate on the air lter, airow will be
reduced, lowering operating efciency and increasing noise.
• During periods of normal use, the air lters should be cleaned every
two weeks.
• Do not operate the air conditioner with the intake grille open.
9387602005-02_OM.indb 10 25/01/2019 13:22:49
En-11
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
Cleaning and Care (continued)
Air cleaning lter installation
1 Open the intake grille and remove the air lters.
Air lter (Right & Left)
2 Install the air cleaning lter set (set of 2).
(1) Set the air cleaning lter into the air cleaning lter frame.
Air cleaning lter
Air cleaning lter frame
(2) Engage the latch at each corners of the lter with the four
hooks at the rear of the air cleaning lter frame.
Hook (4 places at the rear)
Latch (4 places)
Take care that the air cleaning lter does not project beyond the
frame.
3 Install the two air lters and close the intake grille.
• When air cleaning lters are used, the effect will increased by
setting the fan speed to High.
Replacing dirty air cleaning lters
Replace lters with the following components (purchased separately).
• Apple-catechin lter: UTR-FA16
• Ion deodorization lter: UTR-FA16-2
1 Open the intake grille and remove the air lters.
2 Replace them by two new air cleaning lters.
(1) Remove the old air cleaning lters in reverse order of their
installation.
(2) Install in the same way as for installation of the air cleaning
lter set.
3 Install the two air lters and close the intake grille.
[In regard to the air cleaning lters]
Apple-catechin lter (1 sheet)
• The lters are disposable lters. (They cannot be washed and
reused.)
• For storage of the lters, use the lters as soon as possible after the
package has been opened.
(The air cleaning effect decreases when the lters are left in the
opened package)
• Generally, the lters should be exchanged about every 3 months.
Please buy dedicated Apple-catechin lter (UTR-FA16) (Sold
separately) to exchange the used dirty air cleaning lters.
Ion deodorization lter (1 sheet) - light blue
• The lters should be exchanged about every 3 years so as to
maintain the deodorizing effect.
Please buy dedicated Ion deodorization lter (UTR-FA16-2) (Sold
separately) when exchanging the lters.
[Maintenance of Ion deodorization lter]
In order to maintain the deodorizing effect, please clean the lter in the
following way every 3 months.
1. Remove the lter.
2. Clean with water and dry in the air.
(1) Flush the lters with high-pressure hot water until the surface
of the lters are covered with water. Please ush with diluent
neutral detergent.
(Never wash by reaming or rubbing, otherwise it will damage
the deodorizing effect.)
(2) Rinse with water ow.
(3) Dry in shade.
3. Reinstall the lter.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the
Fan operation for half a day to dry the internal parts throughly before
you perform normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may
reduce the product performance even if you have maintained the unit
with instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.
Filter reset
This function can be used if set correctly during installation. Please
consult authorized service personnel to activate this function.
• The Economy indicator lights on when it is time to clean the air
lters.
• After turning the power on, press the "MANUAL AUTO" button on
the indoor unit for 3 seconds or less.
9387602005-02_OM.indb 11 25/01/2019 13:22:50
En-12 OPERATING MANUAL
WARNING
In the following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel.
As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off.
• Unit smells of something burning or emits smoke
• Water leaks from the unit
Following symptoms do not indicate product malfunction, but they are normal functions or characteristics of this product.
Symptom Cause See page
Operation is delayed after
restart.
To prevent blowout of the fuse, the compressor will not operate while the protection circuit is working
for about 3 minutes after sudden Off→On operation of the power supply. –
Noise is heard. • During operation or immediately after stopping the air conditioner, refrigerant owing sound may be
heard. Also it may be particularly noticeable for 2–3 minutes after starting operation.
• During the operation, a slight squeaking sound produced by the minute expansion and contraction
of the front panel caused by temperature change may be heard.
–
During the Heating operation, a sizzling sound produced by the Automatic defrosting operation may
be heard. 9
Smell coming from the unit. Various smells generated from interior textile, furniture, or cigarette smoke absorbed into the air
conditioner may be emitted. –
Mist or steam is emitted from
the unit.
In the Cooling or Dry mode, a thin mist generated by condensation formed with sudden cooling pro-
cess may be emitted. –
During the Heating operation, the fan built-in the outdoor unit may stop and rising steam generated by
the Automatic defrosting operation may be seen. 9
Airow is weak or stops. • Immediately after the Heating operation is started, the fan speed stays very low temporarily to
warm up the internal parts of the unit.
• In the Heating mode, the outdoor unit stops and the indoor unit operates at very low fan speed if
the room temperature rises above the set temperature.
–
In the Heating mode, the indoor unit temporarily stops for maximum of 15 minutes to perform the
Automatic defrosting operation while the Operation indicator is blinking. 9
In the Dry mode, the indoor unit operates at low fan speed to adjust the room humidity, and may stop
from time to time. –
When the fan speed is set to Quiet, the fan rotates at very low speed and the airow is reduced. –
In the Cooling mode, the indoor unit fan may stop from time to time when the outdoor unit is stopped. 4
When the monitoring operation is performed in the Auto mode, the fan rotates at very low speed. –
Outdoor unit emits water. During the Heating operation, the outdoor unit may emit water generated by the Automatic defrosting
operation. 9
Before you call for or request servicing, troubleshoot a problem by performing following checks:
Symptom Diagnostic See page
Does not operate at all. Has the circuit breaker been turned off?
Has there been a power outage?
Has a fuse blown out or the circuit breaker been tripped?
–
Is the timer operating? 6
Poor cooling or heating perfor-
mance.
Is the air lter dirty? 10
Is the intake grille or outlet port of indoor unit blocked? –
Is the room temperature adjusted appropriately? 4
Is a window or door left opened?
Is direct or strong sunlight shinning into the room in the Cooling operation?
Are there other heating apparatus or computers operating, or too many people in the room in the
Cooling operation?
–
Is the fan speed set to Quiet?
When the fan speed setting is set to Quiet, noise reduction is prioritized and the air-conditioning
performance may become lower. If the volume of provided airow is not agreeable to your prefer-
ence, set the fan speed to Low or higher fan speed.
5
Has the Outdoor Unit Low Noise mode been set? 5
The unit operates differently
from the remote controller
setting.
Are the batteries used in the remote controller exhausted?
Are the batteries used in the remote controller loaded properly? 2
Immediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or diagnostics.
• The Operation indicator and Timer indicator blink while the Economy indicator is blinking fast.
Troubleshooting
9387602005-02_OM.indb 12 25/01/2019 13:22:50