Fujitsu ASYG12KPCA User Manual
Displayed below is the user manual for ASYG12KPCA by Fujitsu which is a product in the Split-System Air Conditioners category. This manual has pages.
Related Manuals
En-1
1. SAFETY PRECAUTIONS
To prevent personal injury or property damage, read this section
carefully before you use this product, and be sure to comply
with the following safety precautions.
Incorrect operation due to failure to follow the instructions may
cause harm or damage, the seriousness of which is classifi ed
as follows:
WARNING
This mark warns of death or serious injury.
CAUTION
This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor
unit.
WARNING
This symbol shows that this product uses a fl ammable
refrigerant. If the refrigerant is leaked and exposed to
an external ignition source, there is a risk of fi re.
CAUTION
This symbol shows that the operating manual should
be read carefully.
CAUTION
This symbol shows that a service personnel should
be handling this equipment with reference to the
installation manual.
CAUTION
This symbol shows that information is available such
as the operating manual or installation manual.
WARNING
• This product contains no user-serviceable parts.
Always consult authorized service personnel for
repairing, installation, and relocation of this product.
Improper installation or handling will cause leakage,
electric shock, or fi
re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the
electrical breaker or disconnecting the power plug.
Then consult authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should be replaced only by
authorized service personnel in order to avoid a
hazard.
• In the event of refrigerant leakage, be sure to keep
away from fi re or any fl ammables, and consult
authorized service personnel.
• In the event of a thunder storm or any prior sign
of a lightning strike, turn off the air conditioner via
the remote controller, and refrain from touching the
product or the power source to prevent any electrical
hazards.
• This product shall be stored in a room without
continuously operating ignition sources (for example:
open fl ames, an operating gas appliance or an
operating electric heater).
• This product shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
Contents
1. SAFETY PRECAUTIONS .......................................... 1
2. NAME OF PARTS ..................................................... 2
2.1. Remote controller ............................................... 2
2.2. Indoor unit ........................................................... 4
3. BASIC OPERATIONS ............................................... 4
4. AIRFLOW SETTINGS ............................................... 4
4.1. Fan speed setting ............................................... 4
4.2. Airfl ow direction setting ....................................... 4
5. TIMER OPERATIONS ............................................... 5
5.1. On timer or Off timer ........................................... 5
5.2. Program timer ..................................................... 5
5.3. Sleep timer ........................................................ 5
6. ENERGY SAVING OPERATIONS ............................ 5
6.1. Economy operation ............................................. 5
7. OTHER OPERATIONS ............................................. 5
7.1. Powerful operation .............................................. 5
8. CLEANING AND CARE ............................................. 5
9. GENERAL INFORMATION ....................................... 6
10. OPTIONAL PARTS ................................................... 7
10.1. Wireless LAN control ........................................ 7
11. TROUBLESHOOTING .............................................. 8
OPERATING MANUAL
AIR CONDITIONER (Wall Mounted type)
MODEL:
*Please write down the model name.
(Refer to the rating label.)
Before using this product, read these instructions thoroughly
and keep this manual for future reference.
PART No. 9333892009
9333892009_OM.indb 19333892009_OM.indb 1 12/21/2018 2:34:03 PM12/21/2018 2:34:03 PM
En-2
WARNING
• This product shall be stored so as to prevent
mechanical damage from occurring.
• Disposing of the product shall be done properly, in
compliance with national or regional regulations.
• During transportation or relocation of the indoor unit,
pipes shall be covered with the wall hook bracket for
protection.
Do not move this product by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
fl ammable gas to leak during operation).
• This product is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of this product by a
person responsible for their safety. Children should
be supervised to ensure that they do not play with this
product.
• Dispose of the packing materials safely. Tear and
dispose of the plastic packing bags so that children
cannot play with them. There is danger of suff ocation
if children play with the original plastic bags.
• Do not install the unit in area fi lled with mineral oil
such as a factory or area containing a large amount of
splashed oil or steam such as a kitchen.
• Do not start or stop the operation of this product by
inserting or pulling out the power plug, or by turning
on or off the circuit breaker.
• Do not use fl ammable gases near this product.
• Do not expose yourself directly to the cooling airfl ow
for many hours.
• Do not insert your fi ngers or any other objects into
outlet port or inlet port.
• Do not operate with wet hands.
• Do not use means to accelerate the defrosting
process or to clean this product, other than those
recommended by the manufacturer.
• Do not pierce or burn.
CAUTION
• Provide occasional ventilation during use.
• Always operate this product with air fi lters installed.
• Ensure that any electronic equipment is at least 1 m (40
in) away from this product.
• Disconnect all the power supply when not using this
product for extended periods.
• After a long period of use, ensure to get the mounting
of the indoor unit checked to prevent this product from
falling down.
• The airfl ow direction and the room temperature should
be carefully considered when you use this product in a
room with infants, children, elderly or sick persons.
• Keep the surroundings of the outdoor unit clean and
tidy, and do not place items around it. Any objects
blocking or entering from the outlet ports may cause
product malfunction.
• Do not direct the airfl ow at fi replaces or heating apparatus.
• Do not block or cover the intake grille and the outlet port.
• Do not apply any heavy pressure to radiator fi ns.
• Do not climb on, place objects on, or hang objects
from this product.
• Do not place any other electrical products or
household belongings under this product. Dripping
condensation from this product might get them wet,
and may cause damage or malfunction of your
property.
• Do not expose this product directly to water.
CAUTION
• Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects.
This may cause quality deterioration of those items.
• Do not expose animals or plants to the direct airfl ow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable.
• Do not touch the aluminum fi ns of heat exchanger
built-in this product to avoid personal injury when you
maintain the unit.
• Do not stand on unstable steps when operating or
cleaning this product. It may overturn and can cause
injury.
This product contains fl uorinated greenhouse gases.
2. NAME OF PARTS
CAUTION
For appropriate signal transmission between the remote
controller and the indoor unit, keep the signal receiver
away from the following items:
- Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous fl uorescent lights, such as
inverter type ones, the signal may not be transmitted
properly. In such a case, consult the store of purchase.
2.1. Remote controller
WARNING
• Take care to prevent infants and young children from
accidentally swallowing the batteries.
CAUTION
• To prevent malfunction or damage of the remote controller:
- Place remote controller at where will not be exposed to
direct sunlight or excessive heat.
- Remove batteries if the product is not going to be used for
an extended period.
• Obstacles such as a curtain or wall between the remote
controller and the indoor unit may aff ect the appropriate
signal transmission.
• If leaking battery fl uid comes in contact with your skin, eyes,
or mouth, immediately rinse with plenty of clean water, and
consult your physician.
• Exhausted batteries must be removed immediately, and be
disposed according to the local laws and regulations of your
region.
• Do not apply strong shocks to the remote controller.
• Do not pour water on the remote controller.
• Do not attempt to recharge dry batteries.
• Do not use dry batteries that has been recharged.
9333892009_OM.indb 29333892009_OM.indb 2 12/21/2018 2:34:03 PM12/21/2018 2:34:03 PM
En-3
:The setting must be done while the setting screen is
displayed for each function.
: The button is controllable only when the air conditioner is
operating.
:The instruction is relating to the wireless LAN control
(optional).
Signal transmitter
Aim at the signal receiver of the indoor unit properly.
• Operating range is approximately 7 m.
• [ ] will appear when the signal is transmitted.
• The indoor unit will emit a beep when it receive the signal
properly. If there is no beep, press the button again.
Do not press this button in normal use.
It starts the test run (for use by authorized service personnel only).
NOTES: If the test run starts unintentionally, press to quit the
test run.
For Energy saving operation ........ Refer to page 5.
Activates or deactivates the Economy
operation.
For Powerful operation ................. Refer to page 5.
Activates or deactivates the Powerful
operation.
Replacing batteries (R03/LR03/AAA x 2)
RESET
4
1
3
2
1~3. Put batteries as shown in the fi gure above.
4. Press as shown in the fi gure above. Use a tip of a
ballpoint pen or other small object.
NOTES:
• Use specifi ed type of batteries only.
• Do not mix diff erent types or new and used batteries together.
• Batteries can be used about 1 year in ordinary use.
• If the remote control range noticeably shortens, replace the batteries.
Remote controller display
In this section, all the possible indicators are displayed for
description. In actual operation, the display is linked with the
button operation, and only shows the necessary indicators for
each setting.
For Basic operations ..................... Refer to page 4.
Starts or stops the air conditioner operation.
Changes the operation mode.
Adjusts the setting temperature.
For Airfl ow settings ....................... Refer to page 4.
Controls the fan speed.
Controls the vertical airfl ow direction.
Sets the automatic Swing operation.
For Timer operations ..................... Refer to page 5.
Activates or deactivates the Sleep timer.
Sets the Off timer.
Sets the On timer.
By pressed down, enters the wireless LAN
setting mode. (Refer to page 7.)
Cancels the timer setting.
By pressed down, activates or deactivates the
wireless LAN control. (Refer to page 8.)
Deactivates the timer setting.
9333892009_OM.indb 39333892009_OM.indb 3 12/21/2018 2:34:03 PM12/21/2018 2:34:03 PM
En-4
2.2. Indoor unit
: The instruction is relating to the wireless LAN control (optional).
Indicator lamps *2) Remote controller
signal receiver
Intake grille *1) W-LAN
adapter slot
Horizontal airfl ow
direction louvers
Drain hose
Air fi lter
Rating label
Front panel
For Manual Auto operation
and Filter indicator reset
(Refer to page 9.)
*1) Before starting operation, make sure that the intake grille is closed
completely. Incomplete closing may aff ect the proper function or
performance of the product.
*2) Indicator lamps light in the following conditions.
Name Color Operation or condition
Operation Green Normal operation
Timer Orange Timer operation
Economy Green Economy operation
W-LAN Orange Wireless LAN control is active.
3. BASIC OPERATIONS
■3 steps to start operation
1. Press to start or stop the operation.
2. Press to select the operation mode.
The operation mode changes as follows.
AUTO COOL DRY FAN HEAT
3. Press to set the desired temperature.
The temperature changes by 1 °C increments.
Temperature setting range
Auto/Cooling/Dry 18 - 30 °C
Heating 16 - 30 °C
NOTES:
• In the Cooling or Dry mode, set the temperature lower than the
current room temperature.
• In the Cooling mode, the indoor unit fan may stop from time to time
to perform Fan control for energy saving that enables power-saving
operation by stopping the rotation of the indoor unit fan when the
outdoor unit is stopped.
In initial setting, this function is activated.
To deactivate the function, consult the installer or authorized service
personnel.
• In the Heating mode,
- set the temperature higher than the current room temperature.
- at the beginning of the operation, the indoor unit fan rotates at very
low speed for 3-5 minutes.
- the Automatic defrosting operation overrides the Heating operation
when necessary.
• In the Fan mode, temperature control is not available.
4. AIRFLOW SETTINGS
4.1. Fan speed setting
) Press to control the fan speed.
The fan speed changes as follows.
AUTO HIGH MED LOW QUIET
When is selected, the fan speed depends on the operating
condition.
4.2. Airfl ow direction setting
For details of the airfl ow ranges, refer to "Airfl ow direction
range".
■Vertical airfl ow direction setting
) Press to adjust the vertical airfl ow direction.
■Horizontal airfl ow direction setting
CAUTION
Before you adjust the horizontal airfl ow direction, make sure
that the vertical airfl ow direction louver has been stopped
completely.
) Adjust two knobs by hand.
■Swing operation setting
) Press to start or stop the Swing operation.
NOTES:
● The Swing operation may stop temporarily when the indoor unit fan
is rotating at very low speed or is stopped.
■Airfl ow direction range
Vertical airfl ow direction
1
2
3
4
56
Change by 1⇄2⇄3⇄4⇄5⇄6
Swing operation by
Cooling, Dry 1 4
Heating 3 6
Fan * 1 4 or 3 6
* the Swing operation range depends on the airfl ow direction set before
the Swing operation.
NOTES:
• Do not adjust the airfl ow direction louvers by hand.
• In the Auto or Heating mode, the airfl ow direction stay position 1 for
a while from the start of the operation.
• In the Cooling or Dry mode, position 1-3 is recommended to prevent
condensation drips damaging your property. If position 4-6 keeps for
30 minutes or more in these modes, the airfl ow direction changes to
position 3 automatically.
• When using the mobile app (optional wireless LAN control is
necessary), the vertical airfl ow can be selected from 4 positions.
9333892009_OM.indb 49333892009_OM.indb 4 12/21/2018 2:34:03 PM12/21/2018 2:34:03 PM
En-5
5. TIMER OPERATIONS
NOTES: When [ ] indicator on the indoor unit blinks, set the clock
and timer again. This blinking shows that the internal clock go
wrong due to an interruption of the power supply. (Refer to
page 7.)
5.1. On timer or Off timer
The On timer starts the operation at your desired time.
The Off timer stops the operation at your desired time.
1. When you use the On timer, press .
When you use the Off timer, press .
2. Each time you press the button, the time changes as follows:
hours
0.5 1.0 1.5 2.0 ... 9.5 10 11 12
• When you use the On timer, set the time while the indicator on
the remote controller display is blinking.
• When you use the Off timer, set the time while the indicator on the
remote controller display is blinking.
• To deactivate the On/Off timer, press while [ ] or [ ]
is shown on the remote controller display.
The indicator will disappear.
5.2. Program timer
The Program timer operates as the combination of the On timer and Off
timer.
) Set On timer and Off timer. (Refer to "5.1. On timer or Off
timer").
First, the timer set earlier will operate.
After the time set by the earlier timer passed, the timer set later will
begin the counting down.
Timer Indicator on the remote controller display
On→Off timer
Off →On timer
NOTES: If you change the setting value for the timer after the Program
timer is set, the counting down of the timer will be reset at that
moment.
5.3. Sleep timer
The Sleep timer supports your comfortable sleep by moderating the air
conditioner operation gradually.
) Press .
Each time you press the button, the time changes as follows:
1.0 2.0 3.0 5.0 7.0
CANCEL hours
9.0
• Set the time while the indicator on the remote controller display
is blinking.
To repeat the timer, press the button when the indicator is not
displayed.
During the Sleep timer operation, the setting temperature changes as
the following fi gure.
In Heating mode
Set
temperature
Set time
1 hour
Set time
1 hour
1.5 hour
30 min.
1 °C 2 °C 3 °C 4 °C
2 °C
1 °C
In Cooling or Dry mode
After the set time has elapsed, the air conditioner operation turns off .
6. ENERGY SAVING OPERATIONS
6.1. Economy operation
It saves more electricity than other operation modes by changing the set
temperature to a moderate setting.
) Press to activate/deactivate the Economy
operation.
[ ] indicator on the indoor unit will turn on.
Operation
mode Room temperature
Cooling/Dry Few degrees higher than the set temperature
Heating Few degrees lower than the set temperature
NOTES:
• In the Cooling, Heating, or Dry mode, the maximum output of this
operation is approximately 70 % of usual operation.
• This operation cannot be performed during the temperature
monitoring by the Auto mode.
7. OTHER OPERATIONS
7.1. Powerful operation
In the Powerful operation, the air conditioner will operate at maximum
power and strong airfl ow to cool down or warm up the room quickly.
) Press to activate/deactivate the Powerful operation.
When activated, the indoor unit will emit 3 short beeps.
When deactivated, the indoor unit will emit 2 short beeps.
The Powerful operation will be turned off automatically in the following
situations:
• The Powerful operation runs for a certain amount of time and the
room temperature reaches the set temperature in the Cooling, Dry,
or Heating mode.
• 20 minutes after the Powerful operation has started.
NOTES:
• The airfl ow direction and the fan speed are controlled automatically.
• The Powerful operation cannot be performed simultaneously with
Economy operation.
8. CLEANING AND CARE
CAUTION
• Before cleaning this product, be sure to turn it off and
disconnect all the power supply.
• Before starting operation, make sure that the intake
grille has been shut completely. Incomplete closing
of the intake grille might have an eff ect on the proper
working or performance of the air conditioner.
• If the fi lter cleaning involves high-place work, please
consult the authorized service personnel.
• Do not touch the aluminum fi ns of heat exchanger
built-in the indoor unit to avoid personal injury when
you maintain the unit.
• Do not expose the indoor unit to liquid insecticides or
hair sprays.
• Do not stand on slippery, uneven or unstable surfaces
when you maintain the unit.
9333892009_OM.indb 59333892009_OM.indb 5 12/21/2018 2:34:04 PM12/21/2018 2:34:04 PM
En-6
Intake grille
Air fi lter
Indoor unit body
The frequency of the cleaning is as shown in the following table.
What to do Frequency
Cleaning indoor unit body When you notice
Cleaning air fi lter Every 2 weeks
Cleaning indoor unit body
NOTES:
• Do not use water hotter than 40 °C.
• Do not use scouring cleanser, volatile solvents such as benzene or
thinner.
1. Wipe the indoor unit body gently with a soft cloth moisten
with warm water.
2. Wipe the indoor unit body gently with a dry and soft cloth.
Cleaning air fi lter
1. Open the intake grille.
2. Remove the air fi lters.
Lift up the air fi lters' handle, disconnect the two lower tabs, and pull
out.
Air fi lter handle
Hooks (2 places)
3. Remove the dust in either of the following ways.
• Cleaning with vacuum cleaner.
• Washing with mild detergent and warm water. After washing, dry the
air fi lters thoroughly in shade.
4. Replace the air fi lters.
Align the sides of the air fi lter with the panel, and push in fully.
Make sure to the two lower tabs are returned to their holes in the
indoor unit properly.
5. Close the intake grille.
Press 4 places on the intake grille to close it completely.
NOTES: If dirt accumulates on the air fi lter, airfl ow will be reduced,
operating effi ciency will lower, and the noise will increase.
Removing and installing intake grille
■Removing intake grille
1. Open the intake grille.
2. While pressing the left and right mounting shafts outward
gently, pull the intake grille.
■Installing intake grille
1. While holding the intake grille horizontal, set the left and
right mounting shafts into the pillow blocks at the top of the
front panel.
Insert the shaft until it snaps to latch each shaft properly.
2. Close the intake grille.
3. Press 4 places on the intake grille to close it completely.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the
Fan mode operation for half a day to dry the internal parts thoroughly
before the normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may
reduce the performance even if you have maintained the unit properly.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.
Filter indicator reset (Special setting)
This function can be used if set correctly during installation. Please
consult authorized service personnel in order to use this function.
) Clean the air fi lter when the indicator lamp show the
following:
Indicator lamp Blinking pattern
Blinks 3 times, at intervals of 21 seconds
After cleaning, reset the fi lter indicator by pushing on the
indoor unit for 2 seconds or less.
9. GENERAL INFORMATION
■Heating performance
This air conditioner operates on the heat-pump principle, absorbing
heat from air outdoors and transferring that heat to the indoor unit. As a
result, the operating performance is reduced as outdoor air temperature
drops.
If you feel that the heating performance is insuffi cient, we recommend
you to use this air conditioner in conjunction with other kinds of heating
appliance.
9333892009_OM.indb 69333892009_OM.indb 6 12/21/2018 2:34:04 PM12/21/2018 2:34:04 PM
En-7
■ Automatic defrosting operation
When outdoor temperature is very low with high humidity, frost may
form on the outdoor unit during the heating operation, and it could
reduce the operating performance of the product.
For frost protection, a microcomputer-controlled automatic defrost
function is equipped in this air conditioner.
If frost forms, the air conditioner will temporarily stop, and defrost circuit
will operate briefl y (maximum of 15 minutes.)
[ ] indicator on the indoor unit blinks during this operation.
If frost forms on the outdoor unit after the Heating operation, the outdoor
unit will stop automatically after it operates for a few minutes. Then the
Automatic defrosting operation starts.
■ Auto-restart function
In event of power interruption such as a blackout, the air conditioner
stops once. But it restarts automatically and performs previous operation
when the power supply is resumed.
If any power interruption occurs after the timer is set, counting down of
the timer will be reset.
After the power supply is resumed, [ ] indicator on the indoor unit
blinks to notify you that there has been a timer fault. In such a case,
reset the clock and timer settings.
■Malfunctions caused by other electrical
devices
Use of other electrical appliances such as an electric shaver or nearby
use of a wireless radio transmitter may cause the malfunction of the air
conditioner.
If you encounter such a malfunction, turn off the circuit breaker once.
Then turn it on again, and resume operation by using the remote
controller.
■Indoor unit temperature and humidity range
Permissible ranges of temperature and humidity are as follows:
Indoor temperature Cooling/Dry [°C] 18 to 32
Heating [°C] 16 to 30
Indoor humidity [%] 80 or less *1)
*1) If the air conditioner is used continuously for many hours, water may
condense on the surface and drip.
• If the unit is operated under the conditions except the permissible
temperature range, the air conditioner operation may stop because
of the automatic protection circuit working.
• Depending on the operating conditions, the heat exchanger may
freeze, causing water leakage or other malfunction (in the Cooling
or Dry mode).
■Other information
• Do not use the air conditioner for any purpose other than room
cooling/dry, room heating or fan.
• For the permissible ranges of temperature and humidity for the
outdoor unit, refer to the outdoor unit installation manual.
10. OPTIONAL PARTS
10.1. Wireless LAN control
The optional wireless LAN control can be used.
For how to operate the mobile app, refer to the operating manual of the
mobile app.
Write down the SSID and the PIN code to the following table.
MAC:
SSID: AP-WF-
PIN:
Wireless LAN label
Connection
port
Information on W-LAN adapter
SSID
PIN
Google Play is a registered trademark of Google Inc.
App store is a service mark of Apple Inc., registered in the U.S. and
other countries.
Setting to use wireless LAN control
Step 1. Application software installation
1. Open “Google Play” or “App Store” depending on the type
of your smartphone or tablet PC.
2. Search for “FGLair”.
3. Install the application software (mobile app) following the
instructions on your screen.
Step 2. User registration
1. Open the installed mobile app.
2. Register the user (with either a smartphone or tablet PC) by
following the instructions in the create an account section of
the mobile app.
Step 3. Installing W-LAN adapter
CAUTION
• Be sure to turn off the power supply of the air
conditioner when installing or removing this product to
avoid the risk of electric shock.
• Do not put fi ngers, sticks etc. in the connection part of
this product and the connection slot of the indoor unit.
Otherwise, electric shock or damage to the product
may occur.
• Do not standing on an unstable platform when
installing or removing this product to avoid injury.
1. Be sure to turn air conditioner off and to disconnect all the
power supply.
2. Open the intake grille.
3. Open the W-LAN adapter cover until it snaps.
4. Plug the W-LAN adapter into the connection slot of the
indoor unit in the direction as shown in the fi gure.
Label side
5. Close the W-LAN adapter cover and the intake grille.
9333892009_OM.indb 79333892009_OM.indb 7 12/21/2018 2:34:05 PM12/21/2018 2:34:05 PM
En-8
Step 4. Air conditioner registration (pairing of W-LAN
adapter)
NOTES:
• Before starting this setting, reconnect the power supply of the air
conditioner and wait for 60 seconds or more.
• Check that the smartphone or tablet PC is linked to the wireless
router you are connecting the air conditioner. The setting will not
work if it is not connected to the same wireless router.
• To control 2 or more air conditioners with the same smartphone or
tablet PC, repeat the setup of the chosen mode.
) Register the air conditioner by following the instructions in
the online manual on FUJITSU GENERAL web site.
www.fujitsu-general.com/global/support/
<How to access the online manual>
1. Sign in to the mobile app.
2. Open the side menu of the mobile app then tap [Help].
3. Tap [WLAN Support].
When the registration is completed, [ ] indicator on the indoor unit
will turn on.
Temporary deactivation of wireless LAN
NOTES:
If you do not press any buttons of the remote controller for 60
seconds, the remote controller display will return to the original
display.
1. Press until the indicators on the
remote controller turn off .
2. Press down on the remote
controller for more than 5 seconds.
will be displayed on the remote controller
display.
3. Select using on the remote
controller. *
4. Press .
[ ] indicator on the indoor unit will turn off .
* If you want to activate wireless LAN again, select in step 2.
Initialization (reset)
Initialize (reset) this product in the following situations:
• Changing the wireless router
• Disposing this product
• Transferring this product to a third party
Unregister the air conditioner
Unregister the air conditioner by using the mobile app. (Refer to the
operating manual of the mobile app for details.)
Initialization of the W-LAN adapter
NOTES:
If you do not press any buttons of the remote controller for 60
seconds, the remote controller display will return to the original
display
.
1. Press until the indicators on the
remote controller turn off .
2. Press down on the remote controller
for more than 5 seconds.
will be displayed on the remote controller
display.
3. Select using on the remote
controller.
4. Press .
on the remote controller display will turn on.
5. Press .
[ ] indicator on the indoor unit will turn off after blinking fast.
To continue use
If you or third party wishes to continue use of the product, follow the
procedures in “Air conditioner registration (pairing of W-LAN adapter)”
to reconnect to a diff erent wireless router.
NOTES: Wireless LAN setup is not possible if the previous owner did
not unregister or initialize this product. In this case, please
contact your authorized service personnel.
11. TROUBLESHOOTING
WARNING
In the following events, immediately stop operation of
the air conditioner, and disconnect all the power supply
by turning off the electrical breaker or disconnecting
the power plug. Then consult your dealer or authorized
service personnel.
As long as the unit is connected to the power supply, it
is not insulated from the power supply even if the unit is
turned off .
• Unit smells of something burning or emits smoke
• Water leaks from the unit
Does not operate at all.
□Has there been a power outage?
In this case, the unit restarts automatically after the power supply
is resumed. (Refer to page 7.)
□Has the circuit breaker been turned off ?
Turn on the circuit breaker.
□Has a fuse blown out or the circuit breaker been tripped?
Replace the fuse or reset the circuit breaker.
□Is the timer operating?
To check or deactivate the timer setting, refer to page 5.
Poor cooling or heating performance.
□Is the unit operating under the conditions except the permissible
temperature range?
In this case, the air conditioner may stop because of the automatic
protection circuit working.
□Is the air fi lter dirty?
Clean the air fi lter. (Refer to page 6.)
□Is the intake grille or outlet port of indoor unit blocked?
Remove the obstructions.
□Is the room temperature adjusted appropriately?
To change the temperature setting, refer to page 4.
□Is a window or door left opened?
Close the window or the door.
□Is the fan speed set to Quiet?
To change the fan speed, refer to page 4.
□<In the Cooling mode> Is direct or strong sunlight shining into the
room?
Close the curtains.
□<In the Cooling mode> Are there other heating apparatus or com-
puters operating, or too many people in the room?
Turn the heating apparatus or computers off , or set the tem-
perature lower. (Refer to page 4.)
Airfl ow is weak or stops.
□Is the fan speed set to Quiet?
To change the fan speed, refer to page 4.
□<In the Heating mode> Have you just started the operation?
In this case, the fan rotates at very low speed temporarily to warm
up the internal parts of the unit.
□<In the Heating mode> Is the room temperature higher than the
set temperature?
In this case, the outdoor unit stops and the indoor unit fan rotates
at very low speed.
9333892009_OM.indb 89333892009_OM.indb 8 12/21/2018 2:34:05 PM12/21/2018 2:34:05 PM
En-9
□<In the Heating mode> Is [ ] indicator blinking?
In this case, the Automatic defrosting operation is working. The in-
door unit stops for maximum of 15 minutes. (Refer to page 7.)
□<In the Dry mode> The indoor unit operates at low fan speed to
adjust the room humidity, and may stop from time to time.
□<In the Auto mode> While the monitoring operation, the fan
rotates at very low speed.
Noise is heard.
□Is the unit operating, or immediate after stopping operation?
In this case, refrigerant fl owing sound may be heard. It may be
particularly noticeable for 2-3 minutes after starting operation.
□Do you hear a slight squeaking sound during the operation?
This sound is produced by the minute expansion and contraction
of the front panel caused by temperature change.
□<In the Heating mode> Do you hear a sizzling sound?
This sound is produced by the Automatic defrosting operation.
(Refer to page 7.)
Smell coming from the unit.
□The air conditioner may absorb various smells generated from
interior textile, furniture, or cigarette smoke. These smells may be
emitted during the operation.
Mist or steam is emitted from the unit.
□<In the Cooling or Dry mode> A thin mist may be generated by
condensation formed with sudden cooling process.
□<In the Heating mode> Is [ ] indicator on the indoor unit blinking?
In this case, steam may rise from the outdoor unit because of the
Automatic defrosting operation.(Refer to page 7.)
Outdoor unit emits water.
□<In the Heating mode> The outdoor unit may emit water gener-
ated by the Automatic defrosting operation. (Refer to page 7.)
The unit operates diff erently from the remote controller setting.
□Are the batteries in the remote controller exhausted?
Replace the batteries.
Operation is delayed after restart.
□Has the power supply turned from Off to On suddenly?
In this case, the compressor will not operate for about 3 minutes
to prevent a blowout of the fuse.
Immediately stop operation and turn off the electrical breaker in
following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or
diagnostics.
• On the indoor unit, [ ] and [ ] blink while [ ] is blinking fast.
NOTES: For any troubleshooting related to the W-LAN control, refer
to the setting manual for W-LAN adapter or the mobile app
installed in your smartphone or tablet PC.
■State of indicator lamps
: The instruction is relating to the wireless LAN control
(optional).
Lighting pattern: Off , On, Blinking, Any state
State Causes and solutions See
page
Automatic defrosting operation
Please wait until fi nishing the defrosting
(maximum of 15 minutes).
7
Filter indicator
Clean the air fi lter and reset the fi lter
sign. 6
Error code display
Consult authorized service personnel. -
Timer setting error because of Auto restart
Reset the clock and timer settings. 7
Test run operation (for authorized
personnel only)
Press to quit the test run.
3
(Slow)
The power to the wireless router is
not on. -
Check that the power to the wireless
router is on.
There is a possibility that the W-LAN
adapter is not properly connected to
the wireless router. 7
Disconnect the power supply to the air
conditioner (via breaker or plug), and
then re-connect.
The software of the W-LAN adapter
is being updated. -
During the air conditioner registration
(pairing of W-LAN adapter) 8
Restricted function
-
■ Manual Auto operation and Filter indicator
reset
You can operate the air conditioner with on the
indoor unit.
Status Length of pressing down Mode or operation
In operation More than 3 seconds Stop
Stopping 2 seconds or less Filter indicator reset
More than 3 seconds and
less than 10 seconds
Auto
More than 10 seconds
(Only for servicing.*)
Forced cooling
*: To stop the forced cooling, press this button or on the remote
controller.
(3 times)
(Fast)
9333892009_OM.indb 99333892009_OM.indb 9 12/21/2018 2:34:05 PM12/21/2018 2:34:05 PM