Table of Contents
- Contents
- Figures
- Tables
- Preface
- Chapter 1
- Overview
- Features
- 8100L Series Switches
- 8100S Twisted Pair Series Switches
- 8100S Fiber Optic Series Switches
- Back Panels
- Management Panels
- Model Naming Conventions
- 10/100Base-TX Twisted Pair Ports
- 10/100/1000Base-T Twisted Pair Ports
- SFP Slots
- Power Over Ethernet
- Stacking Ports
- eco-friendly Button
- LEDs
- Console Port
- Power Supplies
- Power Connectors
- Chapter 2
- Beginning the Installation
- Chapter 3
- Installing the Switch on a Table or in an Equipment Rack
- Chapter 4
- Cabling the Networking Ports
- Chapter 5
- Powering On the Switch
- Chapter 6
- Troubleshooting
- Appendix A
- Technical Specifications
Allied Telesis AT-8100S/48POE-30 User Manual
Displayed below is the user manual for AT-8100S/48POE-30 by Allied Telesis which is a product in the Network Switches category. This manual has pages.
Related Manuals
613-001382 Rev. E
8100L and 8100S Series
Fast Ethernet Switches
AT-8100L/8
AT-8100L/8POE
AT-8100L/8POE-E
AT-8100S/24C
AT-8100S/24
AT-8100S/24POE
AT-8100S/48
AT-8100S/48POE
AT-8100S/16F8-SC
AT-8100S/16F8-LC
AT-8100S/24F-LC
Stand-alone Switch Installation Guide
Copyright 2012 Allied Telesis, Inc.
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names,
logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior
written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for
any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related
to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the
possibility of such damages.
3
Electrical Safety and Emissions Standards
This product meets the following standards.
RFI Emissions: FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A,
C-TICK, CE
EMC (Immunity): EN55024
Electrical Safety: EN60950-1 (TUV), UL 60950-1 (CULUS)
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15
of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate
this equipment.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Warning: In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
Laser Safety EN60825
4
Translated Safety Statements
Important: The indicates that translations of the safety statement are available in the PDF
document “Translated Safety Statements” posted on the Allied Telesis website at
www.alliedtelesis.com.
5
Preface .............................................................................................................................................................................. 13
Document Conventions .......................................................................................................................................................14
Contacting Allied Telesis .....................................................................................................................................................15
Chapter 1: Overview ........................................................................................................................................................ 17
Features ..............................................................................................................................................................................18
8100L and 8100S Models ............................................................................................................................................18
10/100 Mbps Twisted Pair Ports ..................................................................................................................................18
Fiber Optic Ports ..........................................................................................................................................................18
Power over Ethernet.....................................................................................................................................................19
10/100/1000 Mbps Twisted Pair Ports .........................................................................................................................19
SFP Slots .....................................................................................................................................................................19
Stacking Ports ..............................................................................................................................................................20
LEDs.............................................................................................................................................................................20
Installation Options.......................................................................................................................................................20
MAC Address Table .....................................................................................................................................................20
Management Software and Interfaces .........................................................................................................................20
Management Methods..................................................................................................................................................20
Fanless Models ............................................................................................................................................................21
8100L Series Switches ........................................................................................................................................................22
Hardware Features.......................................................................................................................................................22
Front Panels .................................................................................................................................................................23
Front Panel Components .............................................................................................................................................23
8100S Twisted Pair Series Switches...................................................................................................................................24
Hardware Features.......................................................................................................................................................24
Front Panels .................................................................................................................................................................25
Front Panel Components .............................................................................................................................................26
8100S Fiber Optic Series Switches .....................................................................................................................................27
Hardware Features.......................................................................................................................................................27
Front Panels .................................................................................................................................................................28
Fiber Optic Ports ..........................................................................................................................................................29
Back Panels.........................................................................................................................................................................30
Management Panels............................................................................................................................................................32
Model Naming Conventions.................................................................................................................................................33
10/100Base-TX Twisted Pair Ports......................................................................................................................................35
Speed ...........................................................................................................................................................................35
Duplex Mode ................................................................................................................................................................35
Wiring Configuration.....................................................................................................................................................35
Maximum Distance.......................................................................................................................................................36
Power Over Ethernet....................................................................................................................................................36
Cable Requirements.....................................................................................................................................................36
Port Pinouts..................................................................................................................................................................36
10/100/1000Base-T Twisted Pair Ports ...............................................................................................................................37
Speed ...........................................................................................................................................................................37
Duplex Mode ................................................................................................................................................................37
Wiring Configuration.....................................................................................................................................................37
Maximum Distance.......................................................................................................................................................38
Power Over Ethernet....................................................................................................................................................38
Cable Requirements.....................................................................................................................................................38
Contents
Contents
6
Port Pinouts ................................................................................................................................................................. 38
SFP Slots............................................................................................................................................................................ 39
Power Over Ethernet .......................................................................................................................................................... 41
PoE Standards ............................................................................................................................................................ 41
Powered Device Classes............................................................................................................................................. 42
Power Budget .............................................................................................................................................................. 42
Port Prioritization ......................................................................................................................................................... 43
Wiring Implementation................................................................................................................................................. 44
Stacking Ports..................................................................................................................................................................... 45
eco-friendly Button.............................................................................................................................................................. 46
LEDs ................................................................................................................................................................................... 47
10/100Base-TX Twisted Pair Port LEDs...................................................................................................................... 47
10/100/1000Base-T Twisted Pair Port LEDs ............................................................................................................... 48
100Base-FX Port LEDs ............................................................................................................................................... 49
SFP Slot LED .............................................................................................................................................................. 50
Stacking Port LEDs ..................................................................................................................................................... 51
Stack ID LED ............................................................................................................................................................... 51
Console Port ....................................................................................................................................................................... 53
Power Supplies................................................................................................................................................................... 54
Power Connectors .............................................................................................................................................................. 55
Chapter 2: Beginning the Installation ............................................................................................................................ 57
Installation Procedures ....................................................................................................................................................... 58
Reviewing Safety Precautions ............................................................................................................................................ 59
Choosing a Site for the Switch............................................................................................................................................ 63
Unpacking the Switch ......................................................................................................................................................... 64
8100L Series Switches ................................................................................................................................................ 64
8100S Series Switches................................................................................................................................................ 66
AT-8100S/24C Switch ................................................................................................................................................. 67
Chapter 3: Installing the Switch on a Table or in an Equipment Rack ....................................................................... 69
Installing the Switch on a Table or Desktop........................................................................................................................ 70
Installing the Switch in an Equipment Rack........................................................................................................................ 71
Chapter 4: Cabling the Networking Ports ...................................................................................................................... 77
Cabling the Twisted Pair and Fiber Optic Ports .................................................................................................................. 78
Twisted Pair Ports ....................................................................................................................................................... 78
Fiber Optic Ports.......................................................................................................................................................... 79
General Guidelines...................................................................................................................................................... 79
Installing Optional SFP Transceivers.................................................................................................................................. 80
Chapter 5: Powering On the Switch ............................................................................................................................... 85
Powering On an AC Switch................................................................................................................................................. 86
Monitoring the Initialization Processes ........................................................................................................................ 87
Powering On a DC Switch .................................................................................................................................................. 91
Setting the Stack ID Number .............................................................................................................................................. 95
Starting a Local Management Session........................................................................................................................ 95
Starting a Telnet Management Session....................................................................................................................... 96
Changing the Stack ID Number................................................................................................................................... 97
Starting a Management Session......................................................................................................................................... 99
Local Management ...................................................................................................................................................... 99
Telnet Management..................................................................................................................................................... 99
Secure Shell Management ........................................................................................................................................ 100
Web Browser Management ....................................................................................................................................... 100
SNMP ........................................................................................................................................................................ 101
Specifying Ports in the Command Line Interface for Stand-alone Switches.............................................................. 101
Chapter 6: Troubleshooting .......................................................................................................................................... 103
Appendix A: Technical Specifications ......................................................................................................................... 107
Physical Specifications ..................................................................................................................................................... 107
Environmental Specifications............................................................................................................................................ 108
Power Specifications......................................................................................................................................................... 109
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
7
Certifications......................................................................................................................................................................110
Quality and Reliability ........................................................................................................................................................110
RJ-45 Twisted Pair Port Pinouts........................................................................................................................................111
Fiber Optic Port Specifications ..........................................................................................................................................112
RJ-45 Style Serial Console Port Pinouts ...........................................................................................................................114
Stacking Port Pinouts ........................................................................................................................................................114
Contents
8
9
Figure 1: Front Panels of the 8100L Series Switches...........................................................................................................23
Figure 2: Networking Ports and SFP Slots on the 8100L Series Switches...........................................................................23
Figure 3: Front Panels of the 8100S Twisted Pair Series Switches .....................................................................................25
Figure 4: Networking Ports and SFP Slots on the 8100S Series Switches ..........................................................................26
Figure 5: Front Panels of the 8100S Fiber Optic Series Switches........................................................................................28
Figure 6: Front Panels of the 8100S Fiber Optic Series Switches (Continued)....................................................................29
Figure 7: Back Panels of the Single Power Supply Switches ...............................................................................................30
Figure 8: Back Panels of the Dual Power Supply Switches..................................................................................................31
Figure 9: 8100L Series Management Panel .........................................................................................................................32
Figure 10: 8100S Series Management Panel.......................................................................................................................32
Figure 11: Model Naming Conventions for the Twisted Pair 8100L and 8100S Series Switches ........................................33
Figure 12: Model Naming Conventions of the Fiber Optic 8100S Series Switches..............................................................33
Figure 13: 10/100Base-TX Port LEDs ..................................................................................................................................47
Figure 14: 10/100/1000Base-T Port LEDs............................................................................................................................48
Figure 15: 100Base-FX Port LED.........................................................................................................................................49
Figure 16: SFP Slot LEDs ....................................................................................................................................................50
Figure 17: Stacking Port S1 and S2 LEDs............................................................................................................................51
Figure 18: Stack ID LED.......................................................................................................................................................52
Figure 19: Components of the 8100L Series Switches.........................................................................................................65
Figure 20: Components of the 8100S Series Switches ........................................................................................................66
Figure 21: Components of the AT-8100S/24C Switch..........................................................................................................67
Figure 22: Turning the Switch Upside Down ........................................................................................................................71
Figure 23: Removing the Rubber Feet .................................................................................................................................71
Figure 24: Attaching the Brackets to Install the Switch in an Equipment Rack ....................................................................72
Figure 25: Attaching the Brackets to Install the Switch in an Equipment Rack (Continued).................................................73
Figure 26: Attaching the Brackets to 8100L and AT-8100S/24C Switches for Equipment Rack Installation........................74
Figure 27: Attaching the Brackets to 8100L and AT-8100S/24C Switches for Equipment Rack Installation (Continued)....75
Figure 28: Mounting the Switch in an Equipment Rack........................................................................................................75
Figure 29: Removing the Dust Plug from an SFP Slot .........................................................................................................81
Figure 30: Installing an SFP Transceiver..............................................................................................................................81
Figure 31: Removing the Dust Cover from the SFP Module ................................................................................................82
Figure 32: Positioning the SFP Handle in the Upright Position ............................................................................................82
Figure 33: Connecting the Fiber Optic Cable to the SFP Module.........................................................................................83
Figure 34: Plugging in the AC Power Cord...........................................................................................................................86
Figure 35: Switch Initialization Messages.............................................................................................................................89
Figure 36: Switch Initialization Messages (Continued) .........................................................................................................90
Figure 37: DC Terminal Block...............................................................................................................................................92
Figure 38: Stripped Wire.......................................................................................................................................................92
Figure 39: Inserting Wires into the DC Terminal Block.........................................................................................................93
Figure 40: Connecting the Management Cable to the Console Port ....................................................................................95
Figure 41: AlliedWare Plus Command Line Prompt .............................................................................................................97
Figure 42: Moving to the Global Configuration Mode with the ENABLE and CONFIGURE TERMINAL Commands ..........97
Figure 43: STACK Command Confirmation Prompt .............................................................................................................98
Figure 44: PORT Parameter in the Command Line Interface.............................................................................................101
Figure 45: RJ-45 Socket Pin Layout (Front View) ..............................................................................................................111
Figure 46: Stacking Port Pin Layout (Front View)...............................................................................................................114
Figures
Figures
10
11
Tables
Table 1: Hardware Features of the 8100L Series Switches ................................................................................................22
Table 2: Hardware Features of the 8100S Twisted Pair Series ...........................................................................................24
Table 3: Hardware Features of the Fiber Optic 8100S Series Switches .............................................................................27
Table 4: General Specifications of the Fiber Optic Ports .....................................................................................................29
Table 5: Model Naming Conventions for the Twisted Pair 8100L and 8100S Series Switches ...........................................33
Table 6: Model Naming Conventions for the Fiber Optic 8100S Series Switches ...............................................................34
Table 7: Twisted Pair Cable Requirements for the 10/100Base-TX Ports ...........................................................................36
Table 8: Twisted Pair Cable for the 10/100/1000Base-T Ports ...........................................................................................38
Table 9: Combo Ports ..........................................................................................................................................................39
Table 10: IEEE Powered Device Classes ............................................................................................................................42
Table 11: 10/100Base-TX Port LEDs ..................................................................................................................................47
Table 12: 10/101000Base-T Port LEDs ...............................................................................................................................48
Table 13: 100Base-FX Port LED .........................................................................................................................................49
Table 14: SFP Slot LED ......................................................................................................................................................50
Table 15: Stacking Port S1 and S2 LEDs ............................................................................................................................51
Table 16: LEDs and Management Software Initialization ....................................................................................................88
Table 17: Product Dimensions ...........................................................................................................................................107
Table 18: Product Weights ................................................................................................................................................107
Table 19: Ventilation Requirements ...................................................................................................................................108
Table 20: Environmental Specifications for all Switches Except the AT-8100L/8POE-E Switch .......................................108
Table 21: Environmental Specifications for the AT-8100L/8POE-E Switch .......................................................................108
Table 22: Maximum Power Consumptions ........................................................................................................................109
Table 23: Input Voltages ....................................................................................................................................................109
Table 24: Product Certifications .........................................................................................................................................110
Table 25: MTBF .................................................................................................................................................................110
Table 26: Pin Signals for 10 and 100 Mbps .......................................................................................................................111
Table 27: Pin Signals for 1000 Mbps .................................................................................................................................112
Table 28: Fiber Optic Port Specifications for the AT-8100S/16F8-SC Switch ...................................................................112
Table 29: Fiber Optic Port Specifications for the AT-8100S/16F8-LC and AT-8100S/24F-LC Switches ..........................113
Table 30: RJ-45 Style Serial Console Port Pin Signals .....................................................................................................114
Table 31: Stacking Port Pin Signals ..................................................................................................................................114
Tables
12
13
Preface
This guide contains the installation instructions for the 8100L and 8100S
Series of Fast Ethernet switches. This manual explains how to install the
units as stand-alone devices. For instructions on how to install the 8100S
Series switches in a stack configuration, refer to the Stack Installation
Guide for the 8100S Series Switches.
This preface contains the following sections:
“Document Conventions” on page 14
“Contacting Allied Telesis” on page 15
Preface
14
Document Conventions
This document uses the following conventions:
Note
Notes provide additional information.
Caution
Cautions inform you that performing or omitting a specific action
may result in equipment damage or loss of data.
Warning
Warnings inform you that performing or omitting a specific action
may result in bodily injury.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
15
Contacting Allied Telesis
If you need assistance with this product, you may contact Allied Telesis
technical support by going to the Support & Services section of the Allied
Telesis web site at www.alliedtelesis.com/support. You can find links for
the following services on this page:
24/7 Online Support — Enter our interactive support center to
search for answers to your product questions in our knowledge
database, to check support tickets, to learn about RMAs, and to
contact Allied Telesis technical experts.
USA and EMEA phone support — Select the phone number that
best fits your location and customer type.
Hardware warranty information — Learn about Allied Telesis
warranties and register your product online.
Replacement Services — Submit a Return Merchandise
Authorization (RMA) request via our interactive support center.
Documentation — View the most recent installation and user
guides, software release notes, white papers, and data sheets for
your products.
Software Downloads — Download the latest software releases for
your managed products.
For sales or corporate information, go to www.alliedtelesis.com/
purchase and select your region.
Preface
16
17
Chapter 1
Overview
This chapter contains the following sections:
“Features” on page 18
“8100L Series Switches” on page 22
“8100S Twisted Pair Series Switches” on page 24
“8100S Fiber Optic Series Switches” on page 27
“Back Panels” on page 30
“Management Panels” on page 32
“Model Naming Conventions” on page 33
“10/100Base-TX Twisted Pair Ports” on page 35
“10/100/1000Base-T Twisted Pair Ports” on page 37
“SFP Slots” on page 39
“Power Over Ethernet” on page 41
“Stacking Ports” on page 45
“eco-friendly Button” on page 46
“LEDs” on page 47
“Console Port” on page 53
“Power Supplies” on page 54
“Power Connectors” on page 55
Note
This guide contains instructions on how to install the 8100L and
8100S Series switches as stand-alone switches. For instructions on
how to install the 8100S Series switches in a stack configuration,
refer to the Stack Installation Guide for the 8100S Series Switches.
Chapter 1: Overview
18
Features
Here is a list of the switches and their features:
8100L and 8100S
Models
Here are the 8100L and 8100S Series switches:
AT-8100L/8
AT-8100L/8POE
AT-8100L/8POE-E
AT-8100S/24C
AT-8100S/24
AT-8100S/24POE
AT-8100S/48
AT-8100S/48POE
AT-8100S/16F8-SC
AT-8100S/16F8-LC
AT-8100S/24F-LC
10/100 Mbps
Twisted Pair
Ports
Here are the basic features of the 10/100 Mbps twisted pair ports:
8, 24, or 48 ports per switch
10Base-T and 100Base-TX compliant
IEEE 802.3u Auto-Negotiation compliant
Auto-MDI/MDIX
100 meters (328 feet) maximum operating distance
IEEE 802.3x flow control in 10/100Base-TX full-duplex operation
IEEE 802.3x backpressure in 10/100Base-TX half-duplex
operation
Support for jumbo frames up to 10KB
RJ-45 connectors
Fiber Optic Ports Here are the basic features of the fiber optic ports:
16 or 24 ports per switch
100Base-FX compliant
Duplex SC or duplex LC
Maximum distance of 2 kilometers (1.24 miles) for the fiber optic
ports on the AT-8100S/16F8-LC, AT-8100S/16F8-SC, and
AT-8100S/24F-LC Switches
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
19
Power over
Ethernet
Here are the basic features of Power over Ethernet (PoE):
PoE and PoE+ supported on the 10/100Base-TX ports on the
AT-8100L/8POE, AT-8100L/8POE-E, AT-8100S/24POE, and
AT-8100S/48POE Switches
Powered device classes 0 to 4
Power budgets of 180 watts for the AT-8100L/8POE and
AT-8100L/8POE-E Switches and 370 watts for the AT-8100S/
24POE and AT-8100S/48POE Switches
Port prioritization
10/100/1000
Mbps Twisted
Pair Ports
Here are the basic features of the 10/100/1000 Mbps twisted pair ports:
Two ports per switch
10Base-T, 100Base-TX, and 1000Base-T compliant
IEEE 802.3u Auto-Negotiation compliant
Auto-MDI/MDIX
100 meters (328 feet) maximum operating distance
IEEE 802.3x flow control in 10/100Base-TX full-duplex mode
IEEE 802.3x backpressure in 10/100Base-TX half-duplex mode
IEEE 803.3z 1000Base-T flow control
Support for jumbo frames up to 10KB
RJ-45 connectors
SFP Slots Here are the basic features of the SFP slots:
Two slots per switch
Support 100Mbps 100Base-FX or 1000Mbps 1000Base-SX/LX
transceivers
Note
The SFP slots and 10/100/1000Base-TX twisted pair ports are
paired together to form combo ports. For information, refer to “SFP
Slots” on page 39.
Note
SFP transceivers must be purchased separately. For a list of
supported transceivers, contact your Allied Telesis distributor or
reseller.
Chapter 1: Overview
20
Stacking Ports Here are the basic features of the stacking ports on the 8100S Series
switches:
Two stacking ports per switch
10Gbps total bandwidth
High-definition Multimedia Interface (HDMI) connectors
LEDs Here are the port LEDs:
Duplex mode and link/activity LEDs for the twisted pair ports
Link/activity LEDs for the 100Base-FX fiber optic ports
Link/activity LEDs for the SFP slots
Link LEDs for the stacking ports
Stack ID number LED
eco-friendly button turns off the LEDs to conserve electricity
Installation
Options
Here are the installation options for stand-alone switches:
19-inch equipment rack
Desk or tabletop
MAC Address
Table
Here are the basic features of the MAC address tables of the switches:
Storage capacity of 16,000 MAC address entries
Automatic learning and aging
Management
Software and
Interfaces
Here are the management software and management interfaces:
AlliedWare Plus Management Software
Command line interface
Web browser interface
Management
Methods
Here are the methods for managing the switches:
Local management through the Console port
Remote Telnet and Secure Shell management
Remote HTTP and HTTPS web browser management
SNMPv1, v2c, and v3
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
21
Fanless Models Here are the 8100L and 8100S Series switches that do not have fans:
AT-8100L/8 Switch
AT-8100S/24 Switch
AT-8100S/24C Switch
AT-8100S/48 Switch
Chapter 1: Overview
22
8100L Series Switches
The three models in the 8100L Series are listed here:
AT-8100L/8
AT-8100L/8POE
AT-8100L/8POE-E
Hardware
Features
Table 1 lists the hardware features of the 8100L Series switches.
Note
The AT-8100L/8POE-E switch has an extended operating
temperature range, which is signified by the “-E” in the model name.
In all other respects, it is identical to the AT-8100L/8POE switch. The
operating temperature ranges of the models are listed in
“Environmental Specifications” on page 108.
Table 1. Hardware Features of the 8100L Series Switches
Feature 8 8POE 8POE-E
Number of 10/100Base-TX Ports 8 8 8
Number of 10/100/1000Base-T Ports 2 2 2
Number of SFP Slots for 100Mbps 100Base-FX or
1000Mbps 1000Base-SX/LX Transceivers1
222
Stacking Ports No No No
Power over Ethernet No Yes Yes
Power over Ethernet Budget (Watts) - 180 180
Powered Device Classes - 0 to 4 0 to 4
Number of Power Supplies 1 1 1
Power Supply Type AC AC AC
Console Management Port Yes Yes Yes
Ventilation Fan No Yes Yes
1. The SFP transceiver slots and 10/100/1000Base-T ports are paired together to form combo ports. Refer to
“SFP Slots” on page 39 for background information.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
23
Front Panels The front panels of the 8100L Series switches are shown in Figure 1.
Figure 1. Front Panels of the 8100L Series Switches
Front Panel
Components
Figure 2 identifies the Fast and Gigabit Ethernet networking ports and the
SFP slots on the 8100L Series switches.
Figure 2. Networking Ports and SFP Slots on the 8100L Series Switches
AT-8100L/8
AT-8100L/8POE
AT-8100L/8POE-E
10/100Base-TX
Combo 10/100/1000Base-T
Ports and SFP Slots
Ports
Management
Panel
Chapter 1: Overview
24
8100S Twisted Pair Series Switches
The five twisted pair models in the 8100S Series are listed here:
AT-8100S/24C
AT-8100S/24
AT-8100S/24POE
AT-8100S/48
AT-8100S/48POE
For information on the fiber optic models, refer to “8100S Fiber Optic
Series Switches” on page 27.
Hardware
Features
Table 2 lists the hardware features of the twisted pair models of the 8100S
Series switches.
Table 2. Hardware Features of the 8100S Twisted Pair Series
Feature 24C 24 24POE 48 48POE
Number of 10/100Base-TX Ports 24 24 24 48 48
Number of 10/100/1000Base-T Ports 22222
Number of SFP Slots for 100Mbps
100Base-FX or 1000Mbps
1000Base-SX/LX Transceivers1
22222
Stacking Ports Yes Yes Yes Yes Yes
Power over Ethernet No No Yes No Yes
Power over Ethernet Budget (Watts) - - 370 - 370
Powered Device Classes - - 0 to 4 - 0 to 4
Number of Power Supplies 12222
Power Supply Type AC AC or
DC
AC AC AC
Console Management Port Yes Yes Yes Yes Yes
Ventilation Fan No No Yes No Yes
1. The SFP transceiver slots are paired with the 10/100/1000Base-T ports to form combo ports. Refer to “SFP
Slots” on page 39 for background information.
Chapter 1: Overview
26
Front Panel
Components
Figure 4 identifies the Fast and Gigabit Ethernet networking ports and the
SFP slots on the 8100S Series switches.
Figure 4. Networking Ports and SFP Slots on the 8100S Series Switches
10/100Base-TX Ports
Combo
Ports and SFP Slots
10/100/1000Base-T
Management
Panel
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
27
8100S Fiber Optic Series Switches
The three fiber optic models in the 8100S Series are listed here:
AT-8100S/16F8-SC
AT-8100S/16F8-LC
AT-8100S/24F-LC
Hardware
Features
Table 3 lists the hardware features of the fiber optic 8100S Series
switches.
Table 3. Hardware Features of the Fiber Optic 8100S Series Switches
Feature 16F8-SC 16F8-LC 24F-LC
Number of 100Base-FX Fiber Optic Ports 16 16 24
Connectors Duplex SC Duplex LC Duplex LC
Maximum Distance per Port 2 kilometers
(1.24 miles)
2 kilometers
(1.24 miles)
2 kilometers
(1.24 miles)
Number of 10/100Base-TX Ports 8 8 0
Number of 10/100/1000Base-T Ports 2 2 2
Number of SFP Slots for 100Mbps 100Base-FX or
1000Mbps 1000Base-SX/LX Transceivers1
222
Stacking Ports Yes Yes Yes
Power over Ethernet No No No
Number of Power Supplies 2 2 2
Power Supply Type AC AC AC
Console Management Port Yes Yes Yes
Ventilation Fan Yes Yes Yes
1. The SFP transceiver slots and the 10/100/1000Base-T ports are paired together to form combo ports, as
explained in “SFP Slots” on page 39.
Chapter 1: Overview
28
Front Panels The front panels of the fiber optic switches are shown in Figure 5 and
Figure 6 on page 29.
Figure 5. Front Panels of the 8100S Fiber Optic Series Switches
AT-8100S/16F8-SC
AT-8100S/16F8-LC
100Base-FX Fiber
Combo
Ports and SFP Slots
Optic Ports with
10/100Base-TX
Twisted Pair
Duplex SC Connectors Ports
10/100/1000Base-T
Management
Panel
100Base-FX Fiber
Combo
Ports and SFP Slots
Optic Ports with
10/100Base-TX
Twisted Pair
Duplex LC Connectors Ports
10/100/1000Base-T
Management
Panel
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
29
Figure 6. Front Panels of the 8100S Fiber Optic Series Switches
(Continued)
Fiber Optic Ports Table 4 lists the general specifications of the fiber optic ports on the fiber
optic switches.
AT-8100S/24-LC
100Base-FX Fiber
Combo
Ports and SFP Slots
Optic Ports with
Duplex LC Connectors
10/100/1000Base-T
Management
Panel
Table 4. General Specifications of the Fiber Optic Ports
Feature 16F8-SC 16F8-LC 24F-LC
Number of Fiber Optic Ports 16 16 24
Connector Duplex SC Duplex LC Duplex LC
Wavelength Transmit and
receive: 1310 nm
Transmit and
receive: 1310 nm
Transmit and
receive: 1310 nm
Standard 100Base-FX 100Base-FX 100Base-FX
Speed 100 Mbps 100 Mbps 100 Mbps
Maximum Distance 2 kilometers
(1.24 miles)
2 kilometers
(1.24 miles)
2 kilometers
(1.24 miles)
Fiber Optic Cable 50/125 or 62.5/
125 µm (core/
cladding)
multimode fiber
optic cable
50/125 or 62.5/
125 µm
multimode fiber
optic cable
50/125 or 62.5/
125 µm
multimode fiber
optic cable
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
31
Figure 8 shows the back panels of the dual power supply switches.
Figure 8. Back Panels of the Dual Power Supply Switches
AC Power
Connector
AC Power
Connector
(Power Supply 2) (Power Supply 1)
DC Power
Connector
DC Power
Connector
(Power Supply 2) (Power Supply 1)
Dual AC Power Supply Models
Dual DC Power Supply Models
Chapter 1: Overview
32
Management Panels
Figure 9 identifies the components in the management panel on the 8100L
Series switches.
Figure 9. 8100L Series Management Panel
Figure 10 identifies the components in the management panel on the
8100S Series switches.
Figure 10. 8100S Series Management Panel
Console
eco-friendly
Button
Stack ID
Port
LED
Management
Console
eco-friendly
Button
Stack ID
Port
LEDs
Management
Stacking Ports
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
33
Model Naming Conventions
The hardware features of the switches are represented by the letters and
numbers in the model names. The conventions for the twisted pair 8100L
and 8100S Series switches are identified in Figure 11.
Figure 11. Model Naming Conventions for the Twisted Pair 8100L and
8100S Series Switches
The conventions are defined in Table 5.
The letter “C” in the AT-8100S/24C model name denotes that the unit,
which has just one power supply, has a smaller, more compact size than
the other 8100S Series switches.
The “-E” in the AT-8100L/8POE-E model name indicates that the switch
has an extended operating temperature range. For details, refer to
“Environmental Specifications” on page 108.
The model naming conventions for the fiber optic 8100S Series switches
are identified in Figure 12.
Figure 12. Model Naming Conventions of the Fiber Optic 8100S Series
Switches
Table 5. Model Naming Conventions for the Twisted Pair 8100L and
8100S Series Switches
Convention Definition
1 This is the product name.
2 The letter “S” indicates that the model is stackable.
The letter “L” indicates that the model is not stackable.
3 This is the number of 10/100Base-TX ports.
4 The letters “POE” indicate support for Power over
Ethernet.
Chapter 1: Overview
34
The conventions are defined in Table 6.
Table 6. Model Naming Conventions for the Fiber Optic 8100S Series
Switches
Convention Definition
1 This is the product name.
2 The letter “S” indicates that the model is stackable.
3 This is the number of 100Base-FX fiber optic ports.
4 The letter “F” signifies fiber optic.
5 This is the number of 10/100Base-TX ports. The fiber
optic switches that have 10/100Base-TX ports are the
AT-8100S/16F8-SC and AT-8100S/16F8-LC
Switches.
6 This identifies the type of fiber optic connector. The
connectors are listed here:
SC - Duplex SC
LC - Duplex LC
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
35
10/100Base-TX Twisted Pair Ports
The switches have 8, 24, or 48 10/100Base-TX ports.
Speed The ports can operate at either 10 or 100 Mbps. The speeds may be set
manually using the management software or automatically with Auto-
Negotiation (IEEE 802.3u), the default setting.
Duplex Mode The twisted pair ports can operate in either half- or full-duplex mode. The
duplex mode determines the manner in which a port transmits data. A port
set to half-duplex can either transmit or receive data at one time, while a
port operating in full-duplex can transmit and receive data at the same
time. The best network performance is achieved with the full-duplex
setting, but not all network equipment is designed to support that duplex
mode.
The duplex modes, like port speeds, may be set manually using the
management software or automatically with Auto-Negotiation (IEEE
802.3u), the default setting.
The speed and duplex mode settings of a port may be set independently
of each other. For example, a port may be configured such that its speed
is set manually while its duplex mode is established through Auto-
Negotiation.
Note
A switch port that is connected to a network device that does not
support Auto-Negotiation and has a fixed duplex mode of full-duplex
should not set its duplex mode with Auto-Negotiation. A duplex-
mode mismatch in which a switch port and a network device operate
at different duplex modes, may occur. The duplex modes of switch
ports that are connected to network devices that do not support
Auto-Negotiation should be set manually through the management
software.
Wiring
Configuration
The wiring configuration of a port can be MDI or MDI-X. The wiring
configurations of a switch port and a network device connected with
straight-through twisted pair cabling have to be opposite, such that one
device is using MDI and the other MDI-X. For instance, a switch port has
to be set to MDI-X if it is connected to a network device set to MDI.
You may set the wiring configurations of the ports manually or let the
switch configure them automatically with auto-MDI/MDI-X (IEEE 802.3ab-
compliant). This feature enables the switch to negotiate with network
devices to establish the proper settings, so that the ports on the devices
are using different wiring configurations.
Chapter 1: Overview
36
Maximum
Distance
The ports have a maximum operating distance of 100 meters (328 feet).
Power Over
Ethernet
The 10/100Base-TX ports on the AT-8100S/24POE and AT-8100S/
48POE Switches support Power over Ethernet (PoE), which is a standard
whereby DC power is provided by the switch to network devices over the
network twisted pair cables. The switches support PoE (IEEE 802.3af) and
PoE+ (IEEE 802.3at). For background information, refer to “Power Over
Ethernet” on page 41.
Cable
Requirements
The cable requirements of the ports are given in Table 7.
Port Pinouts Refer to Table 26 on page 111 for the port pinouts of the 10/100Base-TX
twisted pair ports.
Table 7. Twisted Pair Cable Requirements for the 10/100Base-TX Ports
Cable Type
10Mbps 100Mbps
Non-
PoE PoE PoE+ Non-
PoE PoE PoE+
Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Yes No No Yes No No
Standard TIA/EIA 568-A-
compliant Category 5 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Yes Yes No Yes Yes No
Standard TIA/EIA 568-B-
compliant Enhanced Category
5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Yes Yes Yes Yes Yes Yes
Standard TIA/EIA 568-B-
compliant Category 6 or 6a
shielded cabling.
Yes Yes Yes Yes Yes Yes
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
37
10/100/1000Base-T Twisted Pair Ports
The switches have two 10/100/1000Base-T ports. These ports are paired
with SFP slots to form combo ports.
Speed The ports can operate at 10, 100, or 1000 Mbps. The speeds may be set
manually using the management software or automatically with Auto-
Negotiation (IEEE 802.3u), the default setting.
Note
The ports must be set to Auto-Negotiation to function at 1000 Mbps.
They are not compatible with devices that are not IEEE 802.3u
compliant.
Duplex Mode The twisted pair ports can operate in either half- or full-duplex mode. The
duplex modes, like port speeds, may be set manually using the
management software or automatically with Auto-Negotiation (IEEE
802.3u), the default setting.
The speed and duplex mode settings of a port may be set independently
of each other. For example, a port may be configured such that its speed
is set manually while its duplex mode is established through Auto-
Negotiation.
Note
A switch port that is connected to a network device that does not
support Auto-Negotiation and has a fixed duplex mode of full-duplex
should not set its duplex mode with Auto-Negotiation. A duplex-
mode mismatch in which a switch port and a network device operate
at different duplex modes, may occur. The duplex modes of switch
ports that are connected to network devices that do not support
Auto-Negotiation should be set manually through the management
software.
Wiring
Configuration
The wiring configuration of a port operating at 10 or 100 Mbps can be MDI
or MDI-X. The wiring configurations of a switch port and a network device
connected with straight-through twisted pair cabling have to be opposite,
such that one device is using MDI and the other MDI-X. For instance, a
switch port has to be set to MDI-X if it is connected to a network device set
to MDI.
You may set the wiring configurations of the ports manually or let the
switch configure them automatically with auto-MDI/MDI-X (IEEE 802.3ab-
compliant). This feature enables the switch to automatically negotiate with
network devices to establish the proper settings.
Chapter 1: Overview
38
The MDI and MDI-X settings do not apply when the ports are operating at
1000 Mbps.
Maximum
Distance
The ports have a maximum operating distance of 100 meters (328 feet).
Power Over
Ethernet
The 10/100/1000Base-T ports on the AT-8100L/8POE, AT-8100S/24POE
and AT-8100S/48POE Switches do not support PoE.
Cable
Requirements
The cable requirements of the ports are given in Table 8.
Port Pinouts Refer to Table 26 on page 111 and Table 27 on page 112 for the port
pinouts of the 10/100/1000Base-T twisted pair ports.
Table 8. Twisted Pair Cable for the 10/100/1000Base-T Ports
Cable Type 10Mbps 100Mbps 1000Mbps
Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Yes Yes No
Standard TIA/EIA 568-A-
compliant Category 5 or TIA/
EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Yes Yes Yes
Standard TIA/EIA 568-B-
compliant Category 6 or 6a
shielded cabling.
Yes Yes Yes
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
39
SFP Slots
The switches have two slots for 100Mbps 100Base-FX or 1000Mbps
1000Base-SX/LX fiber optic transceivers. The transceivers can be used to
connect the switches to other network devices over large distances, build
a high-speed backbone network between network devices, or connect
high-speed devices, such as servers, to your network.
The switches support a variety of short and long distance, 100 and 1000
Mbps fiber optic SFP modules. For a list of supported SFP modules,
contact your Allied Telesis representative or visit our web site.
The two SFP slots are paired with the two 10/100/1000Base-T ports. The
combo ports are listed in Table 9.
The rules for using the combo ports are listed here:
Only one port in a combo pair is active at a time.
The twisted pair port is the default active port.
The SFP slot becomes active when an SFP transceiver establishes
a link to another network node.
The twisted pair port of a combo pair remains deactivated so long
as the SFP transceiver has a link to another network device.
The switch automatically reactivates the twisted pair port if the
companion SFP module loses its network link.
The twisted pair port and SFP module of a combo port share the
same settings, such as VLAN assignments, access control lists,
and spanning tree.
Table 9. Combo Ports
Model 10/100/1000
Base-T Port SFP Slot
AT-8100L/8, AT-8100L/8POE, and
AT-8100L/8POE-E
9R 9
10R 10
AT-8100S/24C, AT-8100S/24,
AT-8100S/24POE, AT-8100S/
16F8-LC, AT-8100S/16F8-SC,
and AT-8100S/24F-LC
25R 25
26R 26
AT-8100S/48 and
AT-8100S/48POE
49R 49
50R 50
Chapter 1: Overview
40
Port speed is an exception to the shared settings of the twisted pair
port and SFP slot of a combo port. If you disable Auto-Negotiation
on the twisted pair port and set the speed and duplex mode
manually, the switch reactivates it when an SFP module
establishes a link with an end node.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
41
Power Over Ethernet
The AT-8100L/8POE, AT-8100L/8POE-E, AT-8100S/24POE, and
AT-8100S/48POE Switches feature Power over Ethernet (PoE) on the 10/
100Base-TX ports. PoE is used to supply power to network devices over
the same twisted pair cables that carry the network traffic.
The main advantage of PoE is that it makes it easier to install a network.
The placement of network devices is often limited by whether there are
power sources nearby. This often limits equipment placement or requires
the added time and cost of having additional electrical sources installed.
But with PoE, you can install PoE-compatible devices wherever they are
needed without having to worry about whether there are power sources
nearby.
A device that provides PoE to other network devices is referred to as
power sourcing equipment (PSE). The AT-8100L/8POE,
AT-8100L/8POE-E, AT-8100S/24POE, and AT-8100S/48POE Switches
act as PSE units by adding DC power to the network cable, thus
functioning as a central power source for other network devices.
Devices that receive their power from a PSE are called powered devices
(PD). Examples include wireless access points, IP telephones, webcams,
and even other Ethernet switches.
The switch automatically determines whether or not a device connected to
a port is a powered device. Ports that are connected to network nodes that
are not powered devices (that is, devices that receive their power from
another power source) function as regular Ethernet ports, without PoE.
The PoE feature remains activated on the ports but no power is delivered
to the devices.
PoE Standards The AT-8100L/8POE, AT-8100L/8POE-E, AT-8100S/24POE, and
AT-8100S/48POE Switches support these PoE standards:
PoE (IEEE 802.3af): This standard provides up to 15.4 watts at the
switch port to support powered devices that require up to 12.95
watts.
PoE+ (IEEE 802.3at): This standard provides up to 30.0 watts at
the switch port to support powered devices that require up to 25.5
watts.
Chapter 1: Overview
42
Powered Device
Classes
Powered devices are grouped into the five classes listed in Table 10 on
page 42. The classes are based on the amount of power the devices
require. The switches support all five classes.
Power Budget The AT-8100L/8POE and AT-8100L/8POE-E Switches have a power
budget of 180 watts. The AT-8100S/24POE and AT-8100S/48POE
Switches have a power budget of 370 watts. These are the maximum
amounts of power the switches can provide at one time to the powered
devices.
The AT-8100S/24POE and AT-8100S/48POE Switches have two power
supplies. Each power supply is responsible for providing 185 watts, or
half, of the power budget. Both power supplies must be connected to AC
power sources for the switch to provide the full 370 watts. The power
budget is reduced to 185 watts if only one power supply is connected to a
power source.
The power requirements of the PoE devices determine the maximum
number of devices the switch can support at one time. So long as the total
power requirements of the powered devices is less than the power budget
of the switch, the switch can supply power to all of the devices. If the total
power requirements exceed the power budget, the switch denies power to
one or more ports using a mechanism referred to as port prioritization.
To determine whether the power requirements of the PoE devices you
plan to connect to the switch exceed its power budget, refer to their
documentation for their power requirements and add the requirements
together. The switch should be able to power all of the devices
simultaneously as long as the total is below its power budget. If the total
exceeds the available power budget, you should consider reducing the
number of PoE devices so that all of the devices receive power.
Otherwise, the switch powers a subset of the devices, based on port
prioritization.
Table 10. IEEE Powered Device Classes
Class
Maximum Power
Output from a Switch
Port
PD Power Range
0 15.4W 0.44W to 12.95W
1 4.0W 0.44W to 3.84W
2 7.0W 3.84W to 6.49W
3 15.4W 6.49W to 12.95W
4 30.0W 12.95W to 25.5W
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
43
The switch can handle different power requirements on different ports.
This enables you to connect different classes of PoE equipment to the
ports on the switch.
Port
Prioritization
If the power requirements of the powered devices exceed the switch’s
power budget, the switch denies power to some ports based on a system
called port prioritization. You may use this mechanism to ensure that
powered devices critical to the operations of your network are given
preferential treatment by the switch in the distribution of power should the
demands of the devices exceed the available capacity.
There are three priority levels:
Critical
High
Low
Ports set to the Critical level, the highest priority level, are guaranteed
power before any of the ports assigned to the other two priority levels.
Ports assigned to the other priority levels receive power only if all the
Critical ports are receiving power. Ports that are connected to your most
critical powered devices should be assigned to this level. If there is not
enough power to support all the ports set to the Critical priority level, power
is provided to the ports based on port number, in ascending order.
The High level is the second highest level. Ports set to this level receive
power only if all the ports set to the Critical level are already receiving
power. If there is not enough power to support all of the ports set to the
High priority level, power is provided to the ports based on port number, in
ascending order.
The lowest priority level is Low. This is the default setting. Ports set to this
level only receive power if all of the ports assigned to the other two levels
are already receiving power. As with the other levels, if there is not enough
power to support all of the ports set to the Low priority level, power is
provided to the ports based on port number, in ascending order.
Power allocation is dynamic. Ports supplying power to powered devices
may cease power transmission if the switch’s power budget is at maximum
usage and new powered devices, connected to ports with higher priorities,
become active.
You can use port prioritization on dual power supply PoE switches to
protect your important networking devices from loss of power should one
of the power supplies fail or lose power. By limiting the power
requirements of the critical devices connected to a switch to less than 185
watts, the PoE power provided by a single power supply, a switch will have
sufficient power to support the critical devices even if it has only one
functional power supply.
Chapter 1: Overview
44
Wiring
Implementation
The IEEE 802.3af standard defines two methods by which a PSE, such as
the switch, can transmit DC power over twisted pair cables to PDs. These
methods, known as modes A and B, identify the wire strands the switch
should use when sending DC power to a PD.
Twisted pair cabling typically consists of eight strands. With 10Base-T and
100Base-TX devices, the strands connected to pins 1, 2, 3, and 6 on the
RJ-45 connectors carry the network traffic while strands connected to pins
4, 5, 7, and 8 are unused. With 1000Base-T devices, all eight strands are
used to carry network data.
It takes four strands to deliver DC power to a PD. With Mode A, the power
is delivered on pins 1, 2, 3, and 6. These are the same pins in 10Base-T
and 100Base-TX devices that carry the network data. With mode B, the
power is provided over the spare strands.
The ports on the AT-8100S/24POE and AT-8100S/48POE Switches
deliver the power using pins 4, 5, 7, and 8, which corresponds to mode B
in the IEEE 802.3af standard.
Powered devices that comply with the IEEE 802.3af standard are required
to support both power delivery methods. Legacy devices that do not
comply with the standard will work with the switch if they are powered on
pins 4, 5, 7, and 8.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
45
Stacking Ports
The 8100S Series switches may be used as stand-alone units or as part of
a virtual stack in which the units are interconnected via the stacking ports
on the front panels. Compared to stand-alone switches, which function as
independent units, the switches of a virtual stack synchronize their actions
to form a single, logical unit so that the switching operations, like spanning
tree protocols, virtual LANs, and static port trunks, are able to span across
all of the units and ports.
The two principal advantages of stacks are:
You can manage multiple units simultaneously, which can simplify
network management.
You have more flexibility in how you configure some of the
features. For instance, a static port trunk on a stand-alone switch
has to consist of ports from the same switch. In contrast, a static
trunk on a stack may consist of ports from different switches in the
same stack.
For instructions on how to install a virtual stack of 8100S Series switches,
refer to the Stack Installation Guide for the 8100S Series Switches.
Note
The 8100L Series switches do not support stacking.
Chapter 1: Overview
46
eco-friendly Button
You may turn off the port LEDs to conserve electricity when you are not
monitoring the switch. The LEDs may be toggled with the eco-friendly
button on the front panel of the switch or the ECOFRIENDLY LED and NO
ECOFRIENDLY LED commands in the Global Configuration mode of the
command line interface.
Toggling the LEDs on and off does not interfere with the network
operations of the device. The Stack ID LED is always on.
Note
When checking or troubleshooting the network connections to the
ports on the switch, you should always check to be sure that the
LEDs are on by either pressing the eco-friendly button or issuing the
ECOFRIENDLY LED and NO ECOFRIENDLY LED commands in
the Global Configuration mode of the command line interface.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
47
LEDs
Here are descriptions of the switch’s LEDs.
10/100Base-TX
Twisted Pair Port
LEDs
The 10/100Base-TX twisted pair ports have link/activity and duplex mode
LEDs.
Figure 13. 10/100Base-TX Port LEDs
The LEDs are described in Table 11.
Table 11. 10/100Base-TX Port LEDs
LED State Description
Link/Activity Off The port has not established a link to an
end node.
Solid green The port has established a link to an end
node.
Flashing
green
The port is receiving or transmitting
packets.
Duplex
Mode
Off The port is operating in half-duplex mode.
Solid green The port is operating in full-duplex mode.
Link/Activity
LED
Duplex Mode
LED
Duplex Mode
LED
Link/Activity
LED
Chapter 1: Overview
48
Here are the LED guidelines:
The LEDs do not display port speed. That information may be
displayed using the management software.
The LEDs do not display PoE information on the AT-8100S/24POE
and AT-8100S/48POE Switches. That information may be viewed
using the management software.
If the port LEDs are off, the switch may be operating in the low
power mode. To toggle on the LEDs, use the eco-friendly button.
10/100/1000Base-T
Twisted Pair Port
LEDs
The twisted pair ports in the combo ports have link/activity and duplex
mode LEDs, just like the 10/100Base-TX ports.
Figure 14. 10/100/1000Base-T Port LEDs
Table 12 describes the LEDs for the 10/100/1000Base-T twisted pair
ports.
Table 12. 10/101000Base-T Port LEDs
LED State Description
Link/Activity Off The port has not established a link to an
end node.
Solid green The port has established a link to an end
node.
Flashing
green
The port is receiving or transmitting
packets.
Duplex Mode
LED
Duplex Mode
LED
Link/Activity
LED
Link/Activity
LED
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
49
100Base-FX Port
LEDs
Each of the 100Base-FX ports on the AT-8100S/16F8-SC, AT-8100S/
16F8-LC, and AT-8100S/24F-LC Switches has a single LED, labeled L/A
for Link/Activity.
Figure 15. 100Base-FX Port LED
The 100Base-FX port LED is described in Table 13.
Duplex
Mode
Off The port is operating in half-duplex mode.
Solid green The port is operating in full-duplex mode.
Table 12. 10/101000Base-T Port LEDs (Continued)
LED State Description
Table 13. 100Base-FX Port LED
LED State Description
Link/Activity Off The port has not established a link to a
network device.
Solid green The port has established a link to a
network device.
Flashing
green
The port is receiving or transmitting
packets to a network device.
100Base-FX Port
LED
Chapter 1: Overview
50
SFP Slot LED Each SFP slot has one LED.
Figure 16. SFP Slot LEDs
The SFP slot LED is described in Table 14.
Table 14. SFP Slot LED
LED State Description
Link/Activity Off The SFP slot is empty or the SFP module
has not established a link to a network
device.
Solid green The SFP module has established a link to
a network device.
Flashing
green
The SFP module is receiving or
transmitting packets to a network device.
SFP Slot
LEDs
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
51
Stacking Port
LEDs
Each stacking port has one link LED labelled LINK/ACT.
Figure 17. Stacking Port S1 and S2 LEDs
The stacking port LED is described in Table 15.
Note
The stacking port LEDs do not indicate packet activity.
Stack ID LED The Stack ID LED, shown in Figure 18 on page 52, displays the ID number
of the switch. A stand-alone switch should have the ID number 0. Switches
connected with the stacking ports to form a virtual stack must have unique
numbers. Chapter 5, “Powering On the Switch” on page 85 has the
procedure for verifying and, if necessary, changing the ID number of the
switch.
Table 15. Stacking Port S1 and S2 LEDs
LED State Description
LINK/ACT Off The stacking port is not connected to
another switch or has not established a
link.
Solid green The stacking port has established a link
with a stacking port on another switch.
Stacking Port
LEDs
Chapter 1: Overview
52
Figure 18. Stack ID LED
The 8100L Series switches do not support stacking, but they have stack
ID LEDs and can be assigned ID numbers because they have the same
management software as the 8100S Series switches. Given that you
cannot stack 8100L Series switches, the correct ID number for these units
is always “0.” Refer to Chapter 5, “Powering On the Switch” on page 85 for
the procedure on how to change the ID number of the switch.
Stack ID
LED
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
53
Console Port
The Console port is used to configure the features and parameter settings
of the switch. This type of management uses serial RS-232 and is
commonly referred to as local or out-of-band management because it is
not conducted over your network. To perform local management, you must
be at the location of the switch and must use the management cable
included with the switch.
To establish a local management session with the switch, you connect a
terminal or a personal computer with a terminal emulation program to the
Console port, which has an RJ-45 style (8P8C) connector, using the
provided management cable. The cable which has RJ-45 RJ-style (8P8C)
and DB-9 (D-sub 9-pin) connectors.
The Console port is set to the following specifications:
Default baud rate: 9600 bps (Range is 9600 to 115200 bps)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
These settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulation program.
Chapter 1: Overview
54
Power Supplies
The 8100L Series switches have one AC power supply. The 8100S Series
switches have two AC or DC power supplies, except for the AT-8100S/
24C Switch, which has one AC power supply. The supplies are not field-
replaceable and each has a separate AC or DC connector on the back
panels.
Only one power supply is active at a time in non-PoE 8100S Series
switches. The second power supply operates in a redundant state and is
automatically activated by the switch if the active power supply loses
power or fails. The change over is instantaneous, making it transparent to
the network users. Power redundancy is available only when both AC
connectors on the switch are connected to power sources.
For all operations excluding PoE, the dual power supplies in the
AT-8100S/24POE and AT-8100S/48POE Switches operate in the same
manner as those in the non-PoE switches. One power supply operates in
an active state while the other resides in a redundant state.
For PoE, however, the power supplies operate in a load-sharing manner,
with each power supply providing 185 watts, half the total PoE budget of
the switch. The maximum 370 watts power budget of PoE is only available
when both power supplies are connected to power sources.
Refer to “Technical Specifications” on page 107 for the input voltage
range.
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. E3
Warning
This unit might have more than one power cord. To reduce the risk
of electric shock, disconnect all power cords before servicing the
unit. E30
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
55
Power Connectors
The 8100S Series switches have two AC or DC power supply sockets on
the back panels, except for the AT-8100S/24C Switch, which has one AC
power supply socket. The 8100L Series switches have one AC power
supply socket.
AC switches are powered on or off by connecting or disconnecting the
power cords. DC switches are powered on or off by energizing or
de-energizing the DC circuit breakers to which the switches are connected
in the wiring closet.
Chapter 1: Overview
56
Chapter 2: Beginning the Installation
58
Installation Procedures
You may install the switch on a table or in an equipment rack. Perform
these procedures to install the switch on a table:
“Reviewing Safety Precautions” on page 59
“Choosing a Site for the Switch” on page 63
“Unpacking the Switch” on page 64
“Installing the Switch on a Table or Desktop” on page 70
“Cabling the Networking Ports” on page 77
“Powering On an AC Switch” on page 86 or “Powering On a DC
Switch” on page 91
“Setting the Stack ID Number” on page 95
Perform these procedures to install the unit in an equipment rack:
“Reviewing Safety Precautions” on page 59
“Choosing a Site for the Switch” on page 63
“Unpacking the Switch” on page 64
“Installing the Switch in an Equipment Rack” on page 71
“Cabling the Networking Ports” on page 77
“Powering On an AC Switch” on page 86 or “Powering On a DC
Switch” on page 91
“Setting the Stack ID Number” on page 95
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
59
Reviewing Safety Precautions
Please review the following safety precautions before you begin the
installation procedure.
Note
The indicates that a translation of the safety statement is
available in a PDF document titled “Translated Safety Statements”
posted on the Allied Telesis website at www.alliedtelesis.com.
Warning
Class 1 Laser product. L1
Warning
Do not stare into the laser beam. L2
Warning
Do not look directly at the fiber optic cable ends or inspect the cable
ends with an optical lens. L6
Warning
To prevent electric shock, do not remove the cover. No user-
serviceable parts inside. This unit contains hazardous voltages and
should only be opened by a trained and qualified technician. To
avoid the possibility of electric shock, disconnect electric power to
the product before connecting or disconnecting the LAN cables.
E1
Warning
Do not work on equipment or cables during periods of lightning
activity. E2
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. E3
Chapter 2: Beginning the Installation
60
Warning
Class I Equipment. This equipment must be earthed. The power
plug must be connected to a properly wired earth ground socket
outlet. An improperly wired socket outlet could place hazardous
voltages on accessible metal parts. E4
Note
Pluggable Equipment. The socket outlet shall be installed near the
equipment and shall be easily accessible. E5
Caution
Air vents must not be blocked and must have free access to the
room ambient air for cooling. E6
Warning
Operating Temperatures. All the switches are designed for a
maximum ambient temperature of 40° degrees C, except the
AT-8100L/8POE-E Switch, which has a maximum ambient
temperature of 50° degrees C.
Note
All Countries: Install product in accordance with local and National
Electrical Codes. E8
Warning
Only trained and qualified personnel are allowed to install or replace
this equipment. E14
Caution
Circuit Overloading: Consideration should be given to the
connection of the equipment to the supply circuit and the effect that
overloading of circuits might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern. E21
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
61
Caution
Risk of explosion if battery is replaced by an incorrect type. Replace
only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the
manufacturer’s instructions.
Attention: Le remplacement de la batterie par une batterie de type
incorrect peut provoquer un danger d’explosion. La remplacer
uniquement par une batterie du même type ou de type équivalent
recommandée par le constructeur. Les batteries doivent être
éliminées conformément aux instructions du constructeur. E22
Warning
Mounting of the equipment in the rack should be such that a
hazardous condition is not created due to uneven mechanical
loading. E25
Note
Use dedicated power circuits or power conditioners to supply reliable
electrical power to the device. E27
Warning
This unit might have more than one power cord. To reduce the risk of
electric shock, disconnect all power cords before servicing the unit.
E30
Note
If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than
the room ambient temperature. Therefore, consideration should be
given to installing the equipment in an environment compatible with
the manufacturer’s maximum rated ambient temperature (Tmra).
E35
Caution
Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not
compromised. E36
Chapter 2: Beginning the Installation
62
Warning
Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than
direct connections to the branch circuits (e.g., use of power strips).
E37
Warning
To reduce the risk of electric shock, the PoE ports on this product
must not connect to cabling that is routed outside the building where
this device is located. E40
Caution
The unit does not contain serviceable components. Please return
damaged units for servicing. E42
Warning
When you remove an SFP module from this product, the case
temperature of the SFP may exceed 40° C (158° F). Exercise
caution when handling with unprotected hands. E43
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
63
Choosing a Site for the Switch
Observe these requirements when planning the installation of the switch.
If you plan to install the switch in an equipment rack, the rack
should be safely secured so that it will not tip over. Devices in a
rack should be installed starting at the bottom, with the heavier
devices near the bottom of the rack.
If you plan to install the switch on a table, the table should be level
and stable.
The power outlet should be located near the switch and be easily
accessible.
The site should allow for easy access to the ports on the front of
the switch, so that you can easily connect and disconnect cables,
and view the port LEDs.
The site should allow for adequate air flow around the unit and
through the cooling vents on the front and rear panels. (The
ventilation direction in units that have a cooling fan is from front to
back, with the fan on the back panel drawing the air out of the unit.)
The site should not expose the switch to moisture or water.
The site should be a dust-free environment.
The site should include dedicated power circuits or power
conditioners to supply reliable electrical power to the network
devices.
The site should not be a wiring or utility box because the switch will
overheat and fail from inadequate airflow.
Warning
Stand-alone switches should not be stacked on top of one another
on a table or desktop because that could present a personal safety
hazard if you need to move or replace switches.
Chapter 2: Beginning the Installation
64
Unpacking the Switch
Refer to the following tables to verify the contents of the shipping
containers of the switches:
For the AT-8100L/8, AT-8100L/8POE, and AT-8100L/8POE-E
Switches, refer to Figure 19 on page 65.
For the twisted pair and fiber optic 8100S Series switches except the
AT-8100S/24C Switch, refer to Figure 20 on page 66.
For the AT-8100S/24C Switch, refer to Figure 21 on page 67.
If any item in the shipping container is missing or damaged, contact your
Allied Telesis sales representative for assistance.
Note
You should retain the original packaging material in the event you
need to return the unit to Allied Telesis
8100L Series
Switches
The AT-8100L/8, AT-8100L/8POE, and AT-8100L/8POE-E Switches
come with the items listed in Figure 19 on page 65.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
65
Figure 19. Components of the 8100L Series Switches
One AT-8100L/8, AT-8100L/8POE, or
AT-8100L/8POE-E Switch
One short rack mounting bracket
One long rack mounting bracket
One 2 m (6.6 ft) local management cable with
RJ-45 (8P8C) and DB-9 (D-sub 9-pin)
connectors.
Eight bracket screws
One regional AC power cord
Chapter 2: Beginning the Installation
66
8100S Series
Switches
The 8100S Series switches, except the AT-8100S/24C Switch, come with
the components listed in Figure 20.
Figure 20. Components of the 8100S Series Switches
One 8100S Series switch
Two rack mounting brackets
One 2 m (6.6 ft) local management cable with
RJ-45 (8P8C) and DB-9 (D-sub 9-pin)
connectors.
Eight bracket screws
Two regional AC power cords
(Not included with DC
powered switches.)
One 1 m (3.3 ft) stacking cable with two type A
HDMI connectors.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
67
AT-8100S/24C
Switch
The AT-8100S/24C Switch comes with the items listed in Figure 21.
Figure 21. Components of the AT-8100S/24C Switch
One AT-8100S/24C Switch
One short rack mounting bracket
One 2 m (6.6 ft) local management cable with
RJ-45 (8P8C) and DB-9 (D-sub 9-pin)
connectors.
Eight bracket screws
One regional AC power cord
One 1 m (3.3 ft) stacking cable with two type A
HDMI connectors.
One long rack mounting bracket
Chapter 2: Beginning the Installation
68
Chapter 3: Installing the Switch on a Table or in an Equipment Rack
70
Installing the Switch on a Table or Desktop
You may install the switch on a table or desktop. Here are the guidelines
to selecting a site:
The table should be level and stable.
The power outlet should be located near the switch and be easily
accessible.
The site should allow for easy access to the ports on the front of
the switch, so that you can easily connect and disconnect cables,
and view the port LEDs.
The site should allow for adequate air flow around the unit and
through the cooling vents on the front and rear panels. (The
ventilation direction in units that have a cooling fan is from front to
back, with the fans on the back panels drawing the air out of the
units.)
The site should not expose the switch to moisture or water.
The site should be a dust-free environment.
The site should include dedicated power circuits or power
conditioners to supply reliable electrical power to the network
devices.
The rubber feet on the bottom of the switch should be left on for
table or desktop installation.
Warning
Do not stack switches on top of one another on a table or desktop
because that could present a personal safety hazard if you need to
move or replace switches.
After placing the switch on the table or desktop, go to Chapter 4, “Cabling
the Networking Ports” on page 77 to connect the network cables to the
ports on the switch.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
71
Installing the Switch in an Equipment Rack
This procedure requires the following items:
Eight bracket screws (included with the switch)
Two equipment rack brackets (included with the switch)
Flat-head screwdriver (not provided)
Cross-head screwdriver (not provided)
Four standard equipment rack screws (not provided)
Installation guidelines may be found in “Choosing a Site for the Switch” on
page 63. Here is the procedure for installing the switch in a 19-inch
equipment rack.
Caution
The chassis may be heavy and awkward to lift. Allied Telesis
recommends that you get assistance when mounting the chassis in
an equipment rack.
E28
1. Place the unit upside down on a level, secure surface.
Figure 22. Turning the Switch Upside Down
2. Using a flat-head screwdriver, pry the rubber feet from the bottom of
the switch.
Figure 23. Removing the Rubber Feet
Chapter 3: Installing the Switch on a Table or in an Equipment Rack
72
3. Turn the switch over.
4. For all switches except the AT-8100L/8, AT-8100L/8POE, and
AT-8100S/24C Switches, secure the two rack mount brackets to the
sides of the switch using the eight bracket screws included with the
unit. Figure 24 here and Figure 25 on page 73 illustrate the four
possible bracket positions.
Figure 24. Attaching the Brackets to Install the Switch in an Equipment
Rack
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
73
Figure 25. Attaching the Brackets to Install the Switch in an Equipment
Rack (Continued)
The AT-8100L/8, AT-8100L/8POE, AT-8100L/8POE-E, and AT-8100S/
24C Switches come with one short bracket and one long bracket.
Allied Telesis recommends installing the short bracket on the right side
and the long bracket on the left side, as you face the front of the unit,
so that the stacking ports on the unit align with the same ports on other
8100L and 8100S Switches in the equipment rack. The possible
positions of the brackets are shown in Figure 26 on page 74 and
Figure 27 on page 75.
Chapter 3: Installing the Switch on a Table or in an Equipment Rack
74
Figure 26. Attaching the Brackets to 8100L and AT-8100S/24C Switches
for Equipment Rack Installation
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
75
Figure 27. Attaching the Brackets to 8100L and AT-8100S/24C Switches
for Equipment Rack Installation (Continued)
5. While another person holds the switch in the equipment rack, secure it
using standard equipment rack screws (not provided).
Figure 28. Mounting the Switch in an Equipment Rack
Go to Chapter 4, “Cabling the Networking Ports” on page 77 to connect the
network cables to the ports on the switch.
Chapter 3: Installing the Switch on a Table or in an Equipment Rack
76
Chapter 4: Cabling the Networking Ports
78
Cabling the Twisted Pair and Fiber Optic Ports
This section contains the guidelines to cabling the twisted pair and fiber
optic ports.
Twisted Pair
Ports
Here are the guidelines to cabling the 10/100Base-TX and 10/100/
1000Base-T twisted pair ports:
The cable specifications for the 10/100Base-TX and 10/100/
1000Base-T twisted pair ports are listed in Table 7 on page 36 and
Table 8 on page 38, respectively.
The connectors on the cables should fit snugly into the ports, and
the tabs should lock the connectors into place.
The default setting for the wiring configurations of the ports is auto-
MDI/MDI-X. The default setting is appropriate for switch ports that
are connected to 10/100Base-TX network devices that also
support auto-MDI/MDI-X.
The default auto-MDI/MDI-X setting is not appropriate for switch
ports that are connected to 10/100Base-TX network devices that
do not support auto-MDI/MDI-X and have a fixed wiring
configuration. For switch ports connected to those types of network
devices, you should disable auto-MDI/MDI-X and set the wiring
configurations manually.
The appropriate MDI/MDI-X setting for a switch port connected to a
10/100Base-TX network device with a fixed wiring configuration
depends on the setting of the network device and whether the
switch and network device are connected with straight-through or
crossover cable. If you are using straight-through twisted pair
cable, the wiring configurations of a port on the switch and a port
on a network device must be opposite each other, such that one
port uses MDI and the other MDI-X. For example, if a network
device has a fixed wiring configuration of MDI, you must disable
auto-MDI/MDI-X on the corresponding switch port and manually
set it to MDI-X. If you are using crossover twisted pair cable, the
wiring configurations of a port on the switch and a port on a
network device must be the same.
The default speed setting for the ports is Auto-Negotiation. This
setting is appropriate for ports connected to network devices that
also support Aut-Negotiation.
The default speed setting of Auto-Negotiation is not appropriate for
ports connected to 10/100Base-TX network devices that do not
support Auto-Negotiation and have fixed speeds. For those switch
ports, you should disable Auto-Negotiation and set the port’s
speed manually to match the speeds of the network devices.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
79
The 10/100/1000Base-T ports must be set to Auto-Negotiation, the
default setting, to operate at 1000Mbps.
The default duplex mode setting for the ports is Auto-Negotiation.
This setting is appropriate for ports connected to network devices
that also support Auto-Negotiation for duplex modes.
The default duplex mode setting of Auto-Negotiation is not
appropriate for ports connected to network devices that do not
support Auto-Negotiation and have a fixed duplex mode. You
should disable Auto-Negotiation on those ports and set their duplex
modes manually to avoid the possibility of duplex mode
mismatches. A switch port using Auto-Negotiation defaults to half-
duplex if it detects that the end node is not using Auto-Negotiation,
which can result in a mismatch if the end node is operating at a
fixed duplex mode of full-duplex.
Fiber Optic Ports Here are the guidelines to cabling the 100Base-FX fiber optic ports:
The cable specifications for the 100Base-FX fiber optic ports are
listed in Table 4 on page 29.
Do not remove the dust covers from the fiber optic ports until you
are ready to connect the fiber optic cables. Dust contamination can
adversely affect the operations of the ports.
The connectors on the cables should fit snugly into the ports, and
the tabs should lock the connectors into place.
General
Guidelines
These guidelines apply to both the twisted pair and fiber optic ports:
If the switch will have a static or an LACP port trunk, you should
create the trunk first using the switch’s management software
before connecting the cables of the trunk. Otherwise, a network
loop will result which can adversely affect network performance.
If your network topology contains a loop where two or more
network devices can communicate with each other over more than
one network path, do not connect the network cables that form the
loop until after you activate one of the spanning tree protocols on
the stack. Data loops can adversely affect network performance.
For background information on the spanning tree protocols, refer to
the AT-8100 Series AlliedWare Plus Command Line Interface
User’s Guide.
Chapter 4: Cabling the Networking Ports
80
Installing Optional SFP Transceivers
Review the following guidelines before installing optional SFP transceivers
in the switch:
The SFP slots are part of combo ports, with 10/100/1000Base-T
ports. For operational information, refer to “SFP Slots” on page 39.
SFP transceivers can be hot-swapped while the switch is powered
on. However, you should always disconnect the fiber optic cable
first before removing a transceiver.
You should install the transceiver before connecting the fiber optic
cable.
Fiber optic transceivers are dust sensitive. Always keep the plug in
the optical bores when a fiber optic cable is not installed, or when
you store the transceiver. When you do remove the plug, keep it
for future use.
Unnecessary removal and insertion of a transceiver can lead to
premature failure.
Warning
A transceiver can be damaged by static electricity. Be sure to
observe all standard electrostatic discharge (ESD) precautions,
such as wearing an antistatic wrist strap, to avoid damaging the
device.
Note
The cable specifications of optional SFP transceivers are found in
the installation guides that ship with the devices.
To install an SFP transceiver:
1. Remove the dust plug from a transceiver slot on the switch. Refer to
Figure 29 on page 81.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
81
Figure 29. Removing the Dust Plug from an SFP Slot
2. Remove the transceiver from its shipping container and store the
packaging material in a safe location.
3. If you are installing the transceiver in the top SFP slot, position the
transceiver with the Allied Telesis label facing up. If you are installing
the transceiver in the bottom slot, position the transceiver with the label
facing down.
4. Slide the transceiver into the slot until it clicks into place, as shown in
Figure 30.
Figure 30. Installing an SFP Transceiver
5. Remove the dust cover from the module, as shown in Figure 31 on
page 82.
Chapter 4: Cabling the Networking Ports
84
Chapter 5: Powering On the Switch
86
Powering On an AC Switch
To power on an AC switch, connect the power cords to the connectors on
the back panels and to the appropriate power sources. All of the models
have two power supplies with separate connectors, except for the
AT-8100S/24C Switch and 8100L Series switches, which have just one
power supply.
Figure 34. Plugging in the AC Power Cord
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
87
Consider the following items as you power on the switch:
Connecting the two power cords to power sources that are on
different circuits will provide power redundancy to the switch in the
event a circuit fails.
The AT-8100S/24POE and AT-8100S/48POE Switches support
370 watts of PoE only when both internal power supplies are
connected to power sources. The switches have a PoE budget of
185 watts if just one power supply is functional. For background
information, refer to “Power Supplies” on page 54.
Refer to “Power Specifications” on page 109 for the power
specifications of the switches.
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. E3
Note
Pluggable Equipment. The socket outlet shall be installed near the
equipment and shall be easily accessible. E5
Monitoring the
Initialization
Processes
It takes a minimum of forty seconds for a stand-alone switch to initialize its
management software programs and features, and load the configuration
file. You may monitor the progress of the initialization process by watching
the LEDs on the front panel. Table 16 on page 88 provides the various
LED states and the approximate time intervals of the initialization phases.
The time length of phase 4, loading the configuration file, varies from a few
seconds to a minute, depending on the number and complexity of the
commands in the file. The stack ID LED acts differently depending on
whether the unit is powered on or reset with the RELOAD or RESET
command.
Chapter 5: Powering On the Switch
88
The base port LEDs are on in phases 1 and 2 if they are connected to live
network devices. Otherwise, they are off. The 10/100/1000Base-T port
LEDs are on in phase 1 regardless of whether they are connected to
active network devices.
You may also monitor the processes by connecting a terminal or computer
that has a terminal emulator program, to the Console port on the master
switch. You will see the messages in Figure 35 on page 89 and Figure 36
on page 90.
Table 16. LEDs and Management Software Initialization
LEDs
Initialize Management
Software
Initialize
Features
Load
Configura-
tion File
Phase 1:
15 seconds
Phase 2:
15 seconds
Phase 3:
10 seconds
Phase 4:
varies
Base port LEDs On On Off Off
10/100/1000Base-T port
and SFP slot LEDs
On Off Off Off
Stack ID LED
Power cycle Off Off Flashing On
RELOAD or
RESET command
On On Flashing On
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
89
Figure 35. Switch Initialization Messages
CFE-NTSW-5.0.0 for BCM956218 (32bit,SP,BE,MIPS)
Build Date: Wed Jul 23 13:47:51 PDT 2008 (jwong@tiramisu)
Copyright (C) 2000, 2001, 2002, 2003, 2004, 2005 Broadcom Corporation.
Initializing Arena.
Initializing Devices.
Board : BCM956218K48
CPU type 0x2901A: 266MHz
Total memory: 0x8000000 bytes (128MB)
Total memory used by CFE: 0x87EBB000 - 0x87FFF6C0 (1328832)
Initialized Data: 0x87EFA224 - 0x87EFC4F0 (8908)
BSS Area: 0x87EFC4F0 - 0x87EFD6C0 (4560)
Local Heap: 0x87EFD6C0 - 0x87FFD6C0 (1048576)
Stack Area: 0x87FFD6C0 - 0x87FFF6C0 (8192)
Text (code) segment: 0x87EBB000 - 0x87EF9AE3 (256739)
Boot area (physical): 0x07E7A000 - 0x07EBA000
Relocation Factor: I:E82BB000 - D:E82BB000
Loader:elf Filesys:raw Dev:flash0.os-Linux File:ATI Options:(null)
Loading: 0x80001000/2341892 0x8023e000/12135086 0x80dd0aae/185714 Entry
at 0x8026c000
Starting program at 0x8026c000
/usr/bin:/bin:/usr/sbin:/sbin
Starting SNMP...
Starting MainTask...
Initializing System ................................. done!
Initializing Board .................................. done!
Initializing Serial Interface ....................... done!
Initializing Timer Library .......................... done!
Initializing IPC .................................... done!
Initializing Event Log .............................. done!
Initializing Switch Models .......................... done!
Initializing File System ............................ done!
Initializing Database ............................... done!
Initializing Configuration .......................... done!
Initializing AW+ CLI ................................ done!
Initializing Drivers ................................ done!
Initializing Port ................................... done!
Initializing Trunk .................................. done!
Initializing Port Security .......................... done!
Initializing LACP ................................... done!
Initializing PORT VLAN .............................. done!
Initializing Port Mirroring ......................... done!
Initializing Port Statistics ........................ done!
Initializing Snmp Service ........................... done!
Initializing Web Service ............................ done!
Chapter 5: Powering On the Switch
90
Figure 36. Switch Initialization Messages (Continued)
After the switch has initialized its management software, go to “Setting the
Stack ID Number” on page 95 to confirm its ID number.
Initializing Monitor ................................ done!
Initializing STP .................................... done!
Initializing SPANNING TREE .......................... done!
Initializing L2_MGMT ................................ done!
Initializing LLDP_RX ................................ done!
Initializing LLDP_TX ................................ done!
Initializing GARP ................................... done!
Initializing GARP Post Init Task .................... done!
Initializing IGMPSnoop .............................. done!
Initializing SYS_MGMT ............................... done!
Initializing SWITCH_MGMT ............................ done!
Initializing L2APP_MGMT ............................. done!
Initializing SNMP_MGMT .............................. done!
Initializing Authentication ......................... done!
Initializing TCPIP .................................. done!
Initializing Default VLAN .......................... done!
Initializing ENCO ................................... done!
Initializing PKI .................................... done!
Initializing PortAccess ............................. done!
Initializing PAAcctRcv .............................. done!
Initializing SSH .................................... done!
Initializing IFM .................................... done!
Initializing IFMV6 .................................. done!
Initializing RTM .................................... done!
Initializing FTAB ................................... done!
Initializing FTABV6 ................................. done!
Initializing ACM .................................... done!
Initializing Filter ................................. done!
Initializing L3_MGMT ................................ done!
Initializing L3APP_MGMT ............................. done!
Initializing SFLOW .................................. done!
Initializing NTP .................................... done!
Initializing CPU_HIST ............................... done!
Initializing EStacking .............................. done!
Initializing MGMT_MGMT .............................. done!
Loading configuration file "boot.cfg" ....... done!
Press <ENTER> key to connect...
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
91
Powering On a DC Switch
Perform this procedure to power on a DC 8100S Series switch:
Warning
As a safety precaution, install a circuit breaker with a minimum value
of 15 Amps between the equipment and the DC power source.
Always connect the wires to the LAN equipment first before you
connect the wires to the circuit breaker. Do not work with HOT feeds
to avoid the danger of physical injury from electrical shock. Always
be sure that the circuit breaker is in the OFF position before
connecting the wires to the breaker.
E9
Warning
For centralized DC power connection, install only in a restricted
access area.
E23
Note
A tray cable is required to connect the power source if the unit is
powered by centralized DC power. The tray cable must be a UL
listed Type TC tray cable and rated at 600 V and 90 degrees C, with
three conductors, minimum 14 AWG.
E24
1. Power off the DC circuit to which the switch will be connected.
2. Use the legend below the terminal block to identify the terminals. The
terminals are positive, power supply ground, and negative, from left
to right, as shown in Figure 37 on page 92.
Chapter 5: Powering On the Switch
92
Figure 37. DC Terminal Block
3. With a 14-gauge wire-stripping tool, strip the three wires in the tray
cable coming from the DC input power source to 8mm 1mm (0.31 in.,
0.039 in.), as shown in Figure 38 on page 92.
Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation. E10
Figure 38. Stripped Wire
4. Insert the power supply ground wire into the middle connector of the
DC terminal and tighten the connection with a flathead screwdriver, as
shown in Figure 39 on page 93.
Warning
When installing this equipment, always ensure that the power supply
ground connection is installed first and disconnected last. E11
Positive Ground Negative
TerminalTerminalTerminal
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
93
Figure 39. Inserting Wires into the DC Terminal Block
5. Connect the positive feed wire to the terminal block marked + (plus).
6. Connect the negative feed wire to the terminal block marked - (minus).
Warning
Check to see if there are any exposed copper strands coming from
the installed wires. When this installation is done correctly there
should be no exposed copper wire strands extending from the
terminal block. Any exposed wiring can conduct harmful levels of
electricity to persons touching the wires. E12
7. Secure the tray cable near the rack framework using multiple cable ties
to minimize the chance of the connections being disturbed by casual
contact with the wiring. Use at least four cable ties, separated four
inches apart. Locate the first one within six inches of the terminal
block.
Note
This system will work with a positive grounded or negative grounded
DC system. E13
8. Verify that the circuit breaker is in the OFF position.
9. Connect the supply-cable wires to the circuit breaker.
10. Energize the circuit breaker.
It takes the switch about forty seconds to initialize its management
software and activate the default settings. (A switch that has a large
number of commands in its boot configuration file may require up to
two minutes to initialize the software.) If you have a terminal or
Chapter 5: Powering On the Switch
94
computer with a terminal emulator program connected to the Console
port on the switch, you will see the messages in Figure 35 on page 89
to Figure 36 on page 90.
11. Repeat this procedure to power on the second power supply.
Warning
This unit might have more than one power source. To reduce the
risk of electric shock, disconnect all power cords before servicing the
unit. E30
12. Go to “Setting the Stack ID Number” on page 95 to confirm the
switch’s ID number.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
95
Setting the Stack ID Number
After the switch has initialized its management software, examine the
Stack ID LED on the front panel and do one of the following:
If the LED is displaying “0,” the installation procedure is complete.
The switch is now ready for network operations as a stand-alone
unit. Refer to the AT-8100 Series AlliedWare Plus Command Line
Interface User’s Guide for instructions on how to configure the
operating parameters.
If the LED is displaying a number other than “0,” perform the
following procedures to change it.
You may set the stack ID number from a local management session of the
switch using the Console port or, because the switch has a factory IP
address, from a Telnet management session from any of the unit’s
networking ports. If you prefer to use the Console port, go to “Starting a
Local Management Session,” next. To use the Telnet application protocol,
go to “Starting a Telnet Management Session” on page 96. (You cannot
use the web browser management interface to change the switch’s stack
ID number.)
Caution
Setting the stack ID number resets the switch. Some network traffic
may be lost if the device is already connected to a live network.
Starting a Local
Management
Session
This procedure requires a terminal or a terminal emulator program and
the management cable that comes with the switch. To start a local
management session on the switch, perform the following procedure:
1. Connect the RJ-45 connector on the management cable to the
Console port on the front panel of the switch.
Figure 40. Connecting the Management Cable to the Console Port
Chapter 5: Powering On the Switch
96
2. Connect the other end of the cable to an RS-232 port on a terminal or
PC with a terminal emulator program.
3. Configure the terminal or terminal emulator program as follows:
Baud rate: 9600 bps (The baud rate of the Console Port is
adjustable from 1200 to 115200 bps. The default is 9600 bps.)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. Press Enter.
You are prompted for a user name and password.
5. When prompted for a user name, go to “Changing the Stack ID
Number” on page 97.
Starting a Telnet
Management
Session
To perform this procedure, you must have Telnet client software on your
computer. This procedure assumes that you will be connecting your
computer to a twisted pair port on the switch. But you may use a fiber optic
port. To start a Telnet management session on the switch using the
factory IP address, perform the following procedure:
1. Assign your computer the IP address 169.254.n.n with the subnet
mask 255.255.0.0. The variable n can be from 1 to 255. You may not
use the switch’s IP address 169.254.1.1. Refer to your computer’s
documentation for instructions on how to set the address.
Note
If your computer is running a DHCP client, it automatically defaults
to an 169.254.n.n address if it does not receive a response from a
DHCP server. To have the DHCP client assign the address,
disconnect your computer from your network, power it on, wait for
the DHCP client to generate the IP address 169.254.n.n, and then
connect the computer to your new 8100L or 8100S Series switch.
2. Connect a twisted pair cable to one of the networking ports on the
switch. You may connect the cable to any of the ports, except the
Console port.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
97
3. Connect the other end of the cable to the Ethernet port on your
computer.
4. Start the Telnet client on your computer and specify the switch’s IP
address, 169.254.1.1.
5. When prompted for a user name, go to “Changing the Stack ID
Number,” next.
Changing the
Stack ID Number
To set the stack ID number, perform the following procedure:
1. When prompted, enter a user name and password to log on the switch.
If this is the initial management session of the switch, enter “manager”
as the user name “friend” as the password. The user name and
password are case sensitive.
The local management session starts when the AlliedWare Plus™
command line prompt, shown in Figure 41. is displayed.
Figure 41. AlliedWare Plus Command Line Prompt
2. Enter the ENABLE and CONFIGURE TERMINAL commands to move
to the Global Configuration mode.
Figure 42. Moving to the Global Configuration Mode with the ENABLE and
CONFIGURE TERMINAL Commands
3. To set the switch’s ID number, use the STACK command, which has
this format:
stack
old_id
renumber
new_id
The OLD_ID parameter is the switch’s current ID number, displayed on
the stack ID LED. The NEW_ID parameter will be the switch’s new ID
number, which, for a stand-alone switch, should be 0. In this example
of the command, the switch’s current ID number is 1:
awplus(config)# stack 1 renumber 0
awplus>
awplus> enable
awplus# configure terminal
awplus(config)#
Chapter 5: Powering On the Switch
98
This confirmation prompt in Figure 43 is displayed.
Figure 43. STACK Command Confirmation Prompt
Caution
The STACK command resets the switch. If the switch is already
connected to a live network, some network traffic may be lost.
4. Type Y to change the switch’s ID number and reset the unit, or N to
cancel the procedure.
5. Wait for the switch to initialize its management software and
afterwards examine the Stack ID LED. The switch is ready for normal
network operations if its stack ID number is “0.” Refer to the AT-8100
Series AlliedWare Plus Command Line Interface User’s Guide for
instructions on how to configure the operating parameters. If the
number is not “0,” repeat this procedure.
*** Warning Stack renumbering requires immediate reboot ***
Stack will restart with new Device ID, all ports will
have new numbering and any port configurations will
probably be lost.
Renumber and reboot system ? (y/n):
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
99
Starting a Management Session
You may use the following methods and tools to manage stand-alone
8100L and 8100S Series switches:
Local management
Telnet client
Secure shell client
HTTP non-secure and HTTPs secure Web browser
SNMPv1, v2C, v3
Local
Management
Local management uses the Console port on the switch. It is commonly
referred to as out-of-band management because the management
sessions are not conducted over your network. Listed here are the
requirements for local management:
A terminal or computer with a terminal emulator program
The management cable included with the switch.
This management method uses the command line interface, which gives
you access to all of the features and parameters on the switch. For
instructions on how to start a local management session, refer to “Starting
a Local Management Session” on page 95.
Telnet
Management
The switch has a Telnet server. You may use the server to manage the
unit over your network with the Telnet application protocol. Commonly
referred to as in-band management because it is conducted over the
network, this management method has these requirements:
Your management workstation must have a Telnet client.
The Telnet server on the switch has to be activated. This is the
server’s default setting.
The switch must have an IP address. You may use the factory
169.254.1.1 address assigned to the Default VLAN, which contains
all of the ports on the switch. For instructions on how to assign the
switch a different address, refer to the AT-8100 Series AlliedWare
Plus Command Line Interface User’s Guide.
You need to assign your management workstation an IP address in
the 169.254.n.n subnet or your workstation must have access to
that subnet through routing devices.
Telnet management uses the Command Line Interface, giving you access
to all of the features and parameter settings on the switch. For instructions
on how to start a Telnet management session on the switch, refer to
“Starting a Telnet Management Session” on page 96.
Chapter 5: Powering On the Switch
100
Telnet management sessions are not secure and are vulnerable to
snooping because the packets exchanged between the switch and your
workstation are sent in plain text. The security of the switch may be
jeopardized if an intruder captures the packet containing your userrname
and password. For secure remote management, use the secure shell
protocol.
Secure Shell
Management
Secure shell management is similar to Telnet management in that you
may use it, together with the Command Line Interface, to manage all of
the features and functions of the switch, from a workstation on your
network. The difference is that this management method encrypts the
packets exchanged by your computer and the switch to protect your
management sessions.
Here are the requirements for SSH management:
Your management workstation must have an SSH client.
The SSH server on the switch has to be activated. The server’s
default setting is disabled.
You have to create an encryption key on the switch.
The switch must have an IP address. You may use the factory
169.254.1.1 address assigned to the Default VLAN.
You need to assign your management workstation an IP address
in the 169.254.n.n subnet or your workstation must have access to
that subnet through routing devices.
For instructions on how to configure the switch for SSH management,
refer to the AT-8100 Series AlliedWare Plus Command Line Interface
User’s Guide.
Web Browser
Management
Yet another way to remotely manage the switch is with a web browser. A
special web browser interface, featuring both non-secure (HTTP) and
secure (HTTPS) operation, lets you monitor and configure many of the
switch’s features from a series of windows. The interface, however, may
only be used to configure a subset of the features. To configure those
features the web browser interface does not support, you have to use the
command line interface from another management method.
Here are the requirements for non-secure HTTP web browser
management:
Your management workstation must have a web browser.
The web browser server on the switch has to be activated. This is
the default setting in the default BOOT.CFG and QSTART.CFG
files.
The switch must have an IP address. You may use the factory
169.254.1.1 address assigned to the Default VLAN.
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
101
You need to assign your management workstation an IP address in
the 169.254.n.n subnet or your workstation must have access to
that subnet through routing devices.
Refer to the AT-8100 Series AlliedWare Plus Command Line Interface
User’s Guide for instructions on how to configure the switch for secure
HTTPS web browser management.
SNMP Refer to the AT-8100 Series AlliedWare Plus Command Line Interface
User’s Guide for instructions on how to configure the switch for SNMP
management. The switch does not have any default SNMP community
strings.
Specifying Ports
in the Command
Line Interface for
Stand-alone
Switches
The command line interface of the Local, Telnet, and SSH management
methods gives you the ability to configure all of the features and
parameters on the switch. Many of the commands have the PORT
parameter, which you use to identify the networking ports on the switch.
This parameter has the following format:
Figure 44. PORT Parameter in the Command Line Interface
The first number is the switch’s stack ID number. The stack ID number in
the PORT parameter for stand-alone switches is not the value 0 displayed
by the Stack ID LED. Rather, it is 1. Be sure to enter 1, not 0, as the stack
ID number in the PORT parameter when configuring stand-alone switches.
The slot ID value, which is used to specify slot numbers in a multi-module
chassis, does not apply to the 8100L and 8100S Series switches and
should always be 0.
The third value is a port number on the switch. You may specify only one
port number in a PORT parameter, but you may specify more than one
PORT parameter in many of the commands where the parameter is
supported.
Here is an example of the PORT parameter on a stand-alone switch. It
uses the INTERFACE command to enter the Port Interface mode for ports
15 and 17:
awplus> enable
awplus# configure terminal
awplus(config)# interface port1.0.15,port1.0.17
port1
.
0
.n
Slot ID
Port Number
Stack ID
Chapter 5: Powering On the Switch
102
For instructions on the command line interface and the PORT parameter,
refer to the AT-8100 Series AlliedWare Plus Command Line Interface
User’s Guide.
103
Chapter 6
Troubleshooting
This chapter contains suggestions on how to troubleshoot the switch if a
problem occurs.
Note
For further assistance, please contact Allied Telesis Technical
Support at www.alliedtelesis.com/support.
Problem 1: The Stack ID LED on the front of the switch is off.
Solutions: The unit is not receiving power. Try the following:
Verify that the power cord is securely connected to the power
source and to the AC connector on the back panel of the switch.
Verify that the power outlet has power by connecting another
device to it.
Try connecting the unit to another power source.
Try a different power cord.
Verify that the voltage from the power source is within the required
levels for your region.
Problem 2: All of the port LEDs are off even though the ports are
connected to active network devices.
Solution: The switch may be operating in the low power mode. To toggle
on the LEDs, press the eco-friendly button on the front panel of the switch.
You may also toggle the LEDs off and on with the ECOFRIENDLY LED
and NO ECOFRIENDLY LED commands in the Global Configuration
mode of the command line interface.
Problem 3: A twisted pair port on the switch is connected to a network
device but the port’s LINK/ACT LED is off.
Solutions: The port is unable to establish a link to a network device. Try
the following:
Verify that the port is connected to the correct twisted pair cable.
This is to eliminate the possibility that the port is connected to the
wrong network device.
Chapter 6: Troubleshooting
104
Verify that the network device connected to the twisted pair port is
powered on and is operating properly.
Try connecting another network device to the twisted pair port with
a different cable. If the twisted pair port is able to establish a link,
then the problem is with the cable or the other network device.
Verify that the twisted pair cable does not exceed 100 meters (328
feet).
Verify that you are using the appropriate category of twisted pair
cable. The cable types are listed in Table 7 on page 36 for the 10/
100Base-TX ports and Table 8 on page 38 for the 10/100/
1000Base-T ports.
Note
A 1000Base connection may require five to ten seconds to establish
a link.
Problem 4: The LINK/ACT LED for an SFP transceiver is off.
Solutions: The fiber optic port on the transceiver is unable to establish a
link to a network device. Try the following:
Verify that the remote network device connected to the fiber optic
port is operating properly.
Verify that the fiber optic cable is securely connected to the port on
the SFP module and to the port on the remote network device.
Check that the SFP module is fully inserted in the slot.
Verify that the operating specifications of the fiber optic ports on
the SFP transceiver and the remote network device are
compatible.
Verify that the correct type of fiber optic cabling is being used.
Verify that the port is connected to the correct fiber optic cable.
This is to eliminate the possibility that the port is connected to the
wrong remote network device.
Try connecting another network device to the fiber optic port using
a different cable. If the port is able to establish a link, then the
problem is with the cable or with the other network device.
Use the switch’s management software to verify that the port is
enabled.
If the remote network device is a managed device, use its
management firmware to determine whether its port is enabled.
Test the attenuation of both directions on the fiber optic cable with
a fiber optic tester to determine whether the optical signal is too
weak (sensitivity) or too strong (maximum input power).
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
105
Problem 5: Network performance between a twisted pair port on the
switch and a network device is slow.
Solution: There might be a duplex mode mismatch between the port and
the network device. This occurs when a twisted pair port using Auto-
Negotiation is connected to a device with a fixed duplex mode of full
duplex. If this is the cause of the problem, adjust the duplex mode of the
port on the network device or switch so that both ports are using the same
duplex mode.
Problem 6: The switch functions intermittently.
Solutions: Check the system hardware status through the management
software:
Use the SHOW SYSTEM ENVIRONMENT command in the
Privileged Exec mode to verify that the input voltage from the
power source to the switch is stable and within the approved
operating range. The unit will shutdown if the input voltage
fluctuates above or below the approved operating range.
For switches that have a ventilation fan, use the SHOW SYSTEM
ENVIRONMENT command in the Privileged Exec mode to verify
that it is operating correctly.
Verify that the location of the switch allows for adequate airflow.
The unit will shutdown if it is in danger of overheating.
Chapter 6: Troubleshooting
106
107
Appendix A
Technical Specifications
Physical Specifications
Dimensions (H x W x D)
Weights
Table 17. Product Dimensions
AT-8100L/8
AT-8100L/8POE
AT-8100L/8POE-E
AT-8100S/24C
4.4 cm x 33.0 cm x 20.3 cm
(1.7 in. x 13.0 in. x 8.1 in.)
AT-8100S/24
AT-8100S/48
AT-8100S/24F-LC
4.4 cm x 44.1 cm x 29.1 cm
(1.7 in. x 17.3 in. x 11.5 in.)
AT-8100S/24POE
AT-8100S/48POE
AT-8100S/16F8-SC
AT-8100S/16F8-LC
4.4 cm x 44.1 cm x 32.2 cm
(1.7 in. x 17.3 in. x 12.7 in.)
Table 18. Product Weights
AT-8100L/8 1.9 kg (4.2 lb.)
AT-8100L/8POE 2.3 kg (5.1 lb.)
AT-8100L/8POE-E 2.3 kg (5.1 lb.)
AT-8100S/24C 2.2 kg (4.8 lb.)
AT-8100S/24 3.6 kg (8.0 lb.)
AT-8100S/24POE 5.0 kg (11.0 lb.)
AT-8100S/48 4.0 kg (8.9 lb.)
AT-8100S/48POE 5.6 kg (12.3 lb.)
AT-8100S/16F8-SC 4.1 kg (9.1 lb.)
Appendix A: Technical Specifications
108
Ventilation
Environmental Specifications
AT-8100S/16F8-LC 4.4 kg (9.75 lb.)
AT-8100S/24F-LC 4.4 kg (9.75 lb.)
Table 19. Ventilation Requirements
Recommended Minimum
Ventilation on All Sides
10 cm (4.0 in)
Table 18. Product Weights (Continued)
Table 20. Environmental Specifications for all Switches Except the
AT-8100L/8POE-E Switch
Operating Temperature 0° C to 40° C (32° F to 104° F)
Storage Temperature -25° C to 70° C (-13° F to 158° F)
Operating Humidity 5% to 90% noncondensing
Storage Humidity 5% to 95% noncondensing
Maximum Operating Altitude 3,048 m (10,000 ft)
Maximum Nonoperating Altitude 4,000 m (13,100 ft)
Table 21. Environmental Specifications for the AT-8100L/8POE-E Switch
Operating Temperature 0° C to 50° C (32° F to 122° F)
Storage Temperature -25° C to 70° C (-13° F to 158° F)
Operating Humidity 5% to 90% noncondensing
Storage Humidity 5% to 95% noncondensing
Maximum Operating Altitude 3,048 m (10,000 ft)
Maximum Nonoperating Altitude 4,572 m (15,100 ft)
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
109
Power Specifications
Maximum Power Consumptions
Input Voltages
Table 22. Maximum Power Consumptions
AT-8100L/8 9.1 watts
AT-8100L/8POE 229.1 watts
AT-8100L/8POE-E 229.1 watts
AT-8100S/24C 18.3 watts
AT-8100S/24 19.5 watts
AT-8100S/24POE 459.3 watts
AT-8100S/48 23.2 watts
AT-8100S/48POE 462.9 watts
AT-8100S/16F8-SC 22 watts
AT-8100S/16F8-LC 22 watts
AT-8100S/24F-LC 22 watts
Table 23. Input Voltages
AT-8100L/8 AC model: 100-240 VAC, 1.0 A
maximum, 50/60 Hz
AT-8100L/8POE AC model: 100-240 VAC, 3.0 A
maximum, 50/60 Hz per input
AT-8100L/8POE-E AC model: 100-240 VAC, 3.0 A
maximum, 50/60 Hz per input
AT-8100S/24C AC model: 100-240 VAC, 1.0 A
maximum, 50/60 Hz per input
AT-8100S/24 AC model: 100-240 VAC, 1.0 A
maximum, 50/60 Hz per input
DC model: 40-60 VDC, 1.5 A
maximum per input
AT-8100S/24POE AC model: 100-240 VAC, 3.0 A
maximum, 50/60 Hz per input
Appendix A: Technical Specifications
110
Certifications
Quality and Reliability
AT-8100S/48 AC model: 100-240 VAC, 1.0 A
maximum, 50/60 Hz per input
AT-8100S/48POE AC model: 100-240 VAC, 3.0 A
maximum, 50/60 Hz per input
AT-8100S/16F8-SC AC model: 100-240 VAC, 1.0 A
maximum, 50/60 Hz per input
AT-8100S/16F8-LC AC model: 100-240 VAC, 1.0 A
maximum, 50/60 Hz per input
AT-8100S/24F-LC AC model: 100-240 VAC, 1.0 A
maximum, 50/60 Hz, per input
Table 23. Input Voltages (Continued)
Table 24. Product Certifications
EMI (Emissions) FCC Class A, EN55022 Class A,
EN61000-3-2, EN61000-3-3, VCCI
Class A, CISPR Class A, C-TICK,
CE
EMC (Immunity) EN55024
Electrical and Laser Safety EN60950-1 (TUV), UL 60950-1
(CULUS), EN60825
Compliance Marks CE, CULUS, TUV, C-Tick
Table 25. MTBF
AT-8100L/8 830,000 hours
AT-8100L/8POE 130,000 hours
AT-8100L/8POE-E 130,000 hours
AT-8100S/24C 510,000 hours
AT-8100S/24 430,000 hours
AT-8100S/24POE 70,000 hours
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
111
RJ-45 Twisted Pair Port Pinouts
Figure 45 illustrates the pin layout of the RJ-45 connectors and ports.
Figure 45. RJ-45 Socket Pin Layout (Front View)
Table 26 lists the pin signals for 10 and 100 Mbps.
AT-8100S/48 300,000 hours
AT-8100S/48POE 61,000 hours
AT-8100S/16F8-SC 190,000 hours
AT-8100S/16F8-LC 170,000 hours
AT-8100S/24F-LC 140,000 hours
Table 25. MTBF (Continued)
Table 26. Pin Signals for 10 and 100 Mbps
Pin MDI Signal MDI-X Signal
1TX+ RX+
2TX- RX-
3RX+ TX+
4 Not used Not used
5 Not used Not used
6RX- TX-
7 Not used Not used
8 Not used Not used
Appendix A: Technical Specifications
112
Table 27 lists the pin signals when a port operating at 1000 Mbps.
Fiber Optic Port Specifications
Table 28 lists the specifications of the 100Base-FX fiber optic ports on the
AT-8100S/16F8-SC Switch.
Table 27. Pin Signals for 1000 Mbps
Pinout Pair
1Pair 1 +
2Pair 1 -
3Pair 2 +
4Pair 3 +
5Pair 3 -
6Pair 2 -
7Pair 4 +
8Pair 4 -
Table 28. Fiber Optic Port Specifications for the AT-8100S/16F8-SC
Switch
General
Maximum Distance 2 km
Fiber Optic Cable 50/125 or 62.5/125 µm (core/
cladding) multimode fiber optic
cable
Transmitter
Wavelength 1310 nm
Output optical power with 50/125
µm (core/cladding) multimode
fiber optic cable (BOL)
minimum: -22.5 dBm
maximum: -14 dBm
Output optical power with 62.5/125
µm (core/cladding) multimode
fiber optic cable (BOL)
minimum: -19 dBm
maximum: -14 dBm
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
113
Table 29 lists the specifications of the 100Base-FX fiber optic ports on the
AT-8100S/16F8-LC and AT-8100S/24F-LC Switches.
Receiver
Wavelength 1310 nm
Sensitivity Maximum: -31.8 dBm
Maximum Input Power Minimum: -14 dBm
Table 29. Fiber Optic Port Specifications for the AT-8100S/16F8-LC and
AT-8100S/24F-LC Switches
General
Maximum Distance 2 km
Fiber Optic Cable 50/125 or 62.5/125 µm (core/
cladding) multimode fiber optic
cable
Transmitter
Wavelength 1310 nm
Output optical power with 50/125
µm (core/cladding) multimode
fiber optic cable (BOL)
Minimum: -23.5 dBm
Maximum: -14 dBm
Output optical power with 62.5/125
µm (core/cladding) multimode
fiber optic cable (BOL)
Minimum: -20 dBm
Maximum: -14 dBm
Receiver
Wavelength 1310 nm
Sensitivity Maximum: -31 dBm
Maximum Input Power Minimum: -8 dBm
Table 28. Fiber Optic Port Specifications for the AT-8100S/16F8-SC
Switch (Continued)
Appendix A: Technical Specifications
114
RJ-45 Style Serial Console Port Pinouts
Table 30 lists the pin signals of the RJ-45 style serial Console port.
Stacking Port Pinouts
Figure 46 illustrates the pin layout of the S1 and S2 stacking ports.
Figure 46. Stacking Port Pin Layout (Front View)
Table 31 lists the pin signals of the stacking ports.
Table 30. RJ-45 Style Serial Console Port Pin Signals
Pin Signal
1 Looped to pin 8.
2 Looped to pin 7.
3 Transmit Data
4 Ground
5 Ground
6 Receive Data
7 Looped to pin 2.
8 Looped to pin 1.
Table 31. Stacking Port Pin Signals
Pin S1 Port S2 Port
1 Not connected Not connected
2 Ground Ground
3 Not connected Not connected
Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches
115
4 Transmit data1+ Receive data1+
5 Ground Ground
6 Transmit data1- Receive data1-
7 Receive data0+ Transmit data0+
8 Ground Ground
9 Receive data0- Transmit data0-
10 Not connected Not connected
11 Ground Ground
12 to 19 Not connected Not connected
Table 31. Stacking Port Pin Signals (Continued)
Pin S1 Port S2 Port
Appendix A: Technical Specifications
116