Table of Contents
- AT-x220-28GS Installation Guide
- Contents
- Figure 1: AT-x220-28GS packaging 8
- Figure 2: AT-x220-28GS front panel 9
- Figure 3: AT-x220-28GS back panel 9
- Figure 4: Power LED on the AT-x220-28GS Switch 10
- Figure 5: Fault LED on the AT-x220-28GS Switch 11
- Figure 6: SFP Link/Speed/Activity LEDs on the AT-x220-28GS Switch 12
- Figure 7: USB slot LED on the AT-x220-28GS Switch 13
- Figure 8: ecofriendly button on the AT-x220-28GS switch s 14
- Figure 9: Assembling the rivets 23
- Figure 10: Inserting the assembled rivets into the hole in the foot 23
- Figure 11: Placing the feet with rivets on the switch 24
- Figure 12: Attaching the rubber feet to a switch 24
- Figure 13: Removing the rubber feet and rivets from a switch 25
- Figure 14: Attaching rack mount brackets to the AT-x220-28GS switch 26
- Figure 15: Mounting the AT-x220-28GS switch in an equipment rack 27
- Figure 16: Positioning the switch on the wall 29
- Figure 17: Attaching wall mount brackets so that the switch is left facing 30
- Figure 18: Attaching wall mount brackets so that the switch right facing 30
- Figure 19: Marking the screw holes from the brackets to the wall 31
- Figure 20: Securing the switch to the wall 32
- Figure 21: Attaching the AC power cable hook on the switch 33
- Figure 22: Plugging in the AC power cord on the Switch 33
- Figure 23: Connecting the management cable to the console port of the x220 Series Switch 36
- Figure 24: Switch initialization messages 37
- Figure 25: Switch initialization messages (continued) 39
- Figure 26: Switch initialization messages (continued) 40
- Figure 27: Inserting an SFP transceiver into an SFP slot 42
- Figure 28: Positioning the SFP handle in the upright position 43
- Figure 29: Ejecting an SFP transceiver after lowering the SFP handle to the downwards position 43
- Figure 30: RJ45 connector and port pin layout 50
- Figures
- Table 1. Power LED functional descriptions 10
- Table 2. Fault LED functional descriptions 11
- Table 3. SFP Link/Activity LED functional descriptions 12
- Table 4. USB LED functional descriptions 13
- Table 5. Chassis dimensions 47
- Table 6. Chassis weight 47
- Table 7. Environmental specifications 48
- Table 8. Input supply voltage 48
- Table 9. Power specifications 48
- Table 10. Safety and electromagnetic emissions certifications 49
- Table 11. RJ-45 Style Serial Consol Port Pin Signals 50
- Tables
- Preface
- Chapter 1: Overview
- Chapter 2: Installation
- Installation
- Reviewing safety precautions
- Selecting a site for the switch
- Unpacking the switch
- Installing the switch on a table or a desktop
- Removing the feet before installing the switch in an equipment rack or on a wall
- Installing the switch in an equipment rack
- Installing the switch on a wall
- Powering on the switch
- Management software
- Starting a local management session
- Monitoring the initialization processes
- Cabling the Network Ports
- Installing SFP transceivers
- Installation
- Chapter 3: Troubleshooting
- Appendix A: Technical Specifications
Allied Telesis x220-28GS User Manual
Displayed below is the user manual for x220-28GS by Allied Telesis which is a product in the Network Switches category. This manual has pages.
Related Manuals
613-02546-00 REV A
AT-x220-28GS
Gigabit Ethernet Switch
Installation Guide
Copyright 2018 Allied Telesis, Inc.
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis,
Inc.
Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names,
company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective
owners.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document
without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied
Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited
to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has
been advised of, known, or should have known, the possibility of such damages.
i
Electrical Safety and Emissions Standards
This product meets the following standards.
Radiated Energy
EMC EN 55024
EN 55032 Class A
EN 61000-3-2
EN 61000-3-3
FCC Part 15 (CFR 47) Class A
VCCI Class A
CISPR 22 Class A
ICES-003
Warning: In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
Environmental RoHS
Compliance WEEE
Electrical Safety EN 60950-1 (edition 2)
IEC 60950-1 (edition 2)
UL 60950-1 (edition 2)
Laser Safety EN 60825
Regulatory RCM
Compliance CE
U.S. Federal Communications Commission
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15
of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate
this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
AT-x230-28GS Switch Installation Guide
iii
Contents
Preface............................................................................................................................................................... 1
Symbol conventions ..................................................................................................................................... 2
Contacting Allied Telesis.............................................................................................................................. 3
User documentation ..................................................................................................................................... 4
Chapter 1: Overview
Features....................................................................................................................................................... 6
SFP slots ............................................................................................................................................... 6
Transceivers .......................................................................................................................................... 6
USB slot................................................................................................................................................. 6
Console port .......................................................................................................................................... 6
LEDs...................................................................................................................................................... 6
Power conservation ............................................................................................................................... 7
MAC address table ................................................................................................................................ 7
Installation options................................................................................................................................. 7
Management software and interfaces ................................................................................................... 7
Management methods........................................................................................................................... 7
Package contents for the AT-x220-28GS Switch......................................................................................... 8
Front and back panels on the AT-x220-28GS Switch .................................................................................. 9
LEDs .......................................................................................................................................................... 10
Power and Fault LEDs......................................................................................................................... 10
SFP LEDs............................................................................................................................................ 11
USB LED ............................................................................................................................................. 13
Ecofriendly button ...................................................................................................................................... 14
Using the button .................................................................................................................................. 14
Using commands................................................................................................................................. 14
Troubleshooting................................................................................................................................... 14
Power supply.............................................................................................................................................. 15
Fans ........................................................................................................................................................... 15
Chapter 2: Installation
Reviewing safety precautions .................................................................................................................... 18
Selecting a site for the switch..................................................................................................................... 21
Unpacking the switch ................................................................................................................................. 22
Installing the switch on a table or a desktop .............................................................................................. 23
Removing the feet before installing the switch in an equipment rack or on a wall ..................................... 25
Installing the switch in an equipment rack.................................................................................................. 26
Installing the switch on a wall..................................................................................................................... 28
Wall guidelines .................................................................................................................................... 28
Tools and materials...............................................................................................................................28
Positions of the switch on a wall.......................................................................................................... 29
Powering on the switch .............................................................................................................................. 33
Management software................................................................................................................................ 35
Starting a local management session ........................................................................................................ 36
Monitoring the initialization processes ....................................................................................................... 37
Cabling the Network Ports ......................................................................................................................... 41
Installing SFP transceivers......................................................................................................................... 42
Chapter 3: Troubleshooting
Appendix A: Technical Specifications
Physical specifications ............................................................................................................................... 47
Contents
iv
Dimensions .......................................................................................................................................... 47
Weight.................................................................................................................................................. 47
Environmental specifications ......................................................................................................................48
Power specifications................................................................................................................................... 48
Electrical safety and electromagnetic certifications .................................................................................... 49
Connectors and port pinouts for the console port.......................................................................................50
v
Figures
Figure 1: AT-x220-28GS packaging ...................................................................................................................................... 8
Figure 2: AT-x220-28GS front panel...................................................................................................................................... 9
Figure 3: AT-x220-28GS back panel ..................................................................................................................................... 9
Figure 4: Power LED on the AT-x220-28GS Switch............................................................................................................ 10
Figure 5: Fault LED on the AT-x220-28GS Switch.............................................................................................................. 11
Figure 6: SFP Link/Speed/Activity LEDs on the AT-x220-28GS Switch.............................................................................. 12
Figure 7: USB slot LED on the AT-x220-28GS Switch........................................................................................................ 13
Figure 8: ecofriendly button on the AT-x220-28GS switch.................................................................................................. 14
Figure 9: Assembling the rivets ........................................................................................................................................... 23
Figure 10: Inserting the assembled rivets into the hole in the foot ...................................................................................... 23
Figure 11: Placing the feet with rivets on the switch............................................................................................................ 24
Figure 12: Attaching the rubber feet to a switch .................................................................................................................. 24
Figure 13: Removing the rubber feet and rivets from a switch ............................................................................................ 25
Figure 14: Attaching rack mount brackets to the AT-x220-28GS switch ............................................................................. 26
Figure 15: Mounting the AT-x220-28GS switch in an equipment rack ................................................................................ 27
Figure 16: Positioning the switch on the wall....................................................................................................................... 29
Figure 17: Attaching wall mount brackets so that the switch is left facing........................................................................... 30
Figure 18: Attaching wall mount brackets so that the switch right facing ............................................................................ 30
Figure 19: Marking the screw holes from the brackets to the wall ...................................................................................... 31
Figure 20: Securing the switch to the wall .......................................................................................................................... 32
Figure 21: Attaching the AC power cable hook on the switch ............................................................................................. 33
Figure 22: Plugging in the AC power cord on the Switch .................................................................................................... 33
Figure 23: Connecting the management cable to the console port of the x220 Series Switch............................................ 36
Figure 24: Switch initialization messages............................................................................................................................ 37
Figure 25: Switch initialization messages (continued) ......................................................................................................... 39
Figure 26: Switch initialization messages (continued) ........................................................................................................ 40
Figure 27: Inserting an SFP transceiver into an SFP slot.................................................................................................... 42
Figure 28: Positioning the SFP handle in the upright position ............................................................................................ 43
Figure 29: Ejecting an SFP transceiver after lowering the SFP handle to the downwards position .................................... 43
Figure 30: RJ45 connector and port pin layout.................................................................................................................... 50
vi
vii
Tables
Table 1. Power LED functional descriptions ......................................................................................................................10
Table 2. Fault LED functional descriptions .........................................................................................................................11
Table 3. SFP Link/Activity LED functional descriptions ......................................................................................................12
Table 4. USB LED functional descriptions ..........................................................................................................................13
Table 5. Chassis dimensions ..............................................................................................................................................47
Table 6. Chassis weight .....................................................................................................................................................47
Table 7. Environmental specifications ................................................................................................................................48
Table 8. Input supply voltage ..............................................................................................................................................48
Table 9. Power specifications .............................................................................................................................................48
Table 10. Safety and electromagnetic emissions certifications .........................................................................................49
Table 11. RJ-45 Style Serial Consol Port Pin Signals ........................................................................................................50
viii
2
Symbol conventions
This document uses the following conventions:
Note
Notes provide additional information.
Caution
Cautions inform you that performing or omitting a specific action
may result in equipment damage or loss of data.
Warning
Warnings inform you that performing or omitting a specific action
may result in bodily injury.
Warning
Warnings inform you that an eye and skin hazard exists due to the
presence of a Class 1 laser device.
AT-x220-28GS Switch Installation Guide
3
Contacting Allied Telesis
If you need assistance with this product, you may contact Allied Telesis
technical support by going to the Support & Services section of the Allied
Telesis web site at www.alliedtelesis.com/support. You can find links for
the following services on this page:
24/7 Online Support - Enter our interactive support center to
search for answers to your questions in our knowledge database,
check support tickets, learn about RMAs, and contact Allied
Telesis technical experts.
USA and EMEA phone support - Select the phone number that
best fits your location and customer type.
Hardware warranty information - Learn about Allied Telesis
warranties and register your product online.
Replacement Services - Submit a Return Merchandise
Authorization (RMA) request via our interactive support center.
Documentation - View the most recent installation guides, user
guides, software release notes, white papers and data sheets for
your product.
Software Updates - Download the latest software releases for your
product.
For sales or corporate contact information, go to
www.alliedtelesis.com/purchase and select your region.
4
User documentation
For full AlliedWare Plus documentation and product information, see our
Resource Library at:
http://www.alliedtelesis.com/support
From the Resource Library the following documents are available:
Datasheets
Click on the link above and search for the product series.
Installation guides
Click on the link above and search for the product series.
Getting Started with AlliedWare Plus Feature Overview and
Configuration Guide
Click on the link above and search for ‘Getting started with
AlliedWare Plus’.
Feature Overview and Configuration Guides
Click on the link above and search for the feature name.
Command References
Click on the link above and search for the product series.
You can also find a range of helpful case studies, solution guides,
whitepapers and videos.
AT-x220-28GS Switch Installation Guide
5
Chapter 1
Overview
This chapter provides descriptions of the AT-x220-28GS Gigabit Ethernet
Switch and contains the following sections:
“Features” on page 6
“Package contents for the AT-x220-28GS Switch” on page 8
“Front and back panels on the AT-x220-28GS Switch” on page 9
“LEDs” on page 10
“Ecofriendly button” on page 14
“Power supply” on page 15
“Fans” on page 15
Chapter 1: Overview
6
Features
This section describes the hardware features on the front panel of the AT-
x220-28GS switch.This model is a Gigabit Advanced Smart-Managed
switch with a total of 28 1 Gbps SFP ports.
SFP slots Ports 1-24 are 100BASE-FX or 1000BASE-X Ethernet LAN ports.
Ports 25-28 are 100BASE-FX or 1000BASE-X Ethernet Uplink
ports.
Transceivers Available for 100Mbps or 1000Mbps of fiber, and 1000Mbps of
copper.
Support 100BASE-FX and 1000BASE-SX/LX SFP transceivers.
SFP transceivers must be purchased separately. For a list of supported
transceivers, contact your Allied Telesis distributor or reseller.
Note
See the product Datasheet for the specific ATI SFP modules
supported by the x220-28GS switch.
USB slot The Management Panel has a USB 2.0 compatible host port, see “USB
LED” on page 13. You may use the port to store configuration files on
flash drives or to restore configuration files to switches whose settings
have been lost or corrupted, or to quickly configure replacement units. You
may also use the port and flash drives to update the management
firmware on the switch.
Console port The Management Panel has a RS-232 serial management port with an
RJ-45 connector. You use the port to access the AlliedWare Plus
management software on the switch to configure the feature settings or
monitor status or statistics. See “Starting a local management session” on
page 34.
LEDs Here is a brief description of the LEDs:
Power and Fault LEDs; refer to “Power and Fault LEDs” on
page 10.
Link/Activity LEDs for the SFP slots; see “SFP LEDs” on page 11.
USB LED; refer to “USB LED” on page 13.
AT-x220-28GS Switch Installation Guide
7
Note
The ecofriendly button on the Management Panel turns off the port
LEDs to conserve electricity (excluding the Fault, Power and USB
LEDs). See “Ecofriendly button” on page 14.
Power
conservation
These switches have the following power conservation features:
Ecofriendly button to turn off the port LEDs when the system is not
being monitored
High efficiency power supply
MAC address
table
Here are the basic features of the MAC address table:
Storage capacity up to 16K MAC address entries
Automatic learning and aging
Installation
options
The switches can be installed in the following ways:
Mounted on a desk or tabletop
Rack mounted in a 19-inch equipment rack
Wall mounted
Management
software and
interfaces
Here are the management software and interfaces:
AlliedWare Plus Management Software
Command Line Interface
Web browser interface
Management
methods
Here are the methods for managing the switches:
Local management through the console port
Remote Telnet or Secure Shell management
Remote HTTP and HTTPS web browser management
Chapter 1: Overview
8
Package contents for the AT-x220-28GS Switch
Figure 1 illustrates the package components that come with the AT-x220-
28GS Gigabit Ethernet Switch.
Figure 1. AT-x220-28GS packaging
One 2 m (6.6ft) local management cable
with RJ-45 (8P8C) and DB-9 (D-sub 9-pin)
One regional AC power cord
Power cord retaining clip
Two rack/wall mounting brackets
Eight bracket screws
Four anchors for concrete walls:
Length: 29.6 mm (1 1/8 in)
Diameter: 6.0 mm (0.25 in)
Four screws for wood or concrete walls:
Length: 31 mm (1/14 in)
Width: 4.3 mm (1/8 in)
Four rubber feet with push-in snap rivets
F
o
AT-x220-28GS Switch Installation Guide
9
Front and back panels on the AT-x220-28GS Switch
Figure 2 illustrates the front panel of the AT-x220-28GS Gigabit Ethernet
Switch.
Figure 2. AT-x220-28GS front panel
27
28
25
26
35179111315171921 23
4681012216 18 2014
22 24
1000 LINK ACT 100 LINK ACT
AT-x220-28GS
FAULT
POWER
USB
ON ACT
ERR
CLASS1
LASER PRODUCT
CONSOLE
ecofriendly button
USB slot
Console port
USB/Fault/Power LEDs
SFP Network ports
Upper (left), lower (right)
SFP port LEDs:
SFP uplink ports
Figure 3 illustrates the back panel of the AT-x220-28GS Gigabit Ethernet
Switch.
Figure 3. AT-x220-28GS back panel
Power connector
Power cable hook
Power cable hook mount
Chapter 1: Overview
10
LEDs
This section describes the four types of LEDs on the AT-x220-28GS
switch:
“Power and Fault LEDs” on page 10
“SFP LEDs” on page 11
“USB LED” on page 13
Power and Fault
LEDs
The Power LED reports the status of AC power and is located on the
Management Panel of the switches beside the console port. See Figure 4.
Note
All port LEDs are OFF when the switch is operating in the low power
mode. To toggle on the LEDs, use the ecofriendly button. See
“Ecofriendly button” on page 14 for more information.
Figure 4. Power LED on the AT-x220-28GS Switch
27
28
FAULT
POWER
USB
ON ACT
ERR
CLASS 1
LASER PRODUCT
CONSOLE
Power LED
Table 1 describes the Power LED for the AT-x220-28GS switch.
Table 1. Power LED functional descriptions
LED State Description
Power
Off
Indicates either the switch is not receiving AC
power or the AC input power is operating outside
the normal range
Steady
green
The switch is receiving AC input power
AT-x220-28GS Switch Installation Guide
11
Figure 5 shows the location of the Fault LED.
Figure 5. Fault LED on the AT-x220-28GS Switch
27
28
FAULT
POWER
USB
ON ACT
ERR
CLASS 1
LASER PRODUCT
CONSOLE
Fault LED
Table 2 describes the functions of the Fault LED.
Table 2. Fault LED functional descriptions
LED State Description
Fault
Off If the POWER LED is on, the switch is receiving
AC input power and is operating normally
Red
flashing
Indicates system warning such as a high
temperature alarm
SFP LEDs The AT-x220-28GS switch has a total of 28 SFP ports. Each SFP port has
an SFP Link/Speed/Activity LED on the front panel. See Figure 6.
The SFP Link/Speed/Activity LEDs indicate the activity status for each
SFP slot. Each SFP slot has ONE bi-color LED:
The left LED corresponds to the upper SFP port
The right LED corresponds to the lower SFP port
Note
All of the port LEDs are OFF when the switch is operating in
ecofriendly mode. See “Ecofriendly button” on page 14 for more
information.
Chapter 1: Overview
12
Figure 6. SFP Link/Speed/Activity LEDs on the AT-x220-28GS Switch
27
28
25
26
23
24
CONSO
Upper (left) SFP LED Lower (right) SFP LED
SFP slots
Table 3 describes the functions of the SFP Link/Speed/Activity LEDs:
Table 3. SFP Link/Activity LED functional descriptions
LED State Description
SFP
Off
The port on the SFP transceiver has not
established a link with an end node, or the
ecofriendly feature is enabled
Flashing
green Rx or Tx activities at 1000M
Steady
green
The SFP transceiver has established a
1000M link with a network device
Flashing
amber Rx or Tx activities at 100M
Steady
amber
The SFP transceiver has established a 100M
Link with a network device
AT-x220-28GS Switch Installation Guide
13
USB LED The AT-x220-28GS switch has a single bi-color USB LED on the
Management Panel (see Figure 7)
Note
All of the port LEDs are off when the switch is operating in
ecofriendly mode. See “Ecofriendly button” on page 14 for more
information.
Figure 7. USB slot LED on the AT-x220-28GS Switch
27
28
FAULT
POWER
USB
ON ACT
ERR
CLASS 1
LASER PRODUCT
CONSOLE
USB LED
USB Slot
The USB LED indicates whether the USB slot has a USB inserted, or is
reading or writing to the USB device. Table 4 describes the functions of
the USB LED.
Table 4. USB LED functional descriptions
LED State Description
USB
Off No USB device detected
Flashing
green Writing or reading
Steady
green USB device inserted and recognized for use
Flashing
amberWriting or reading error
Chapter 1: Overview
14
Ecofriendly button
By pressing the ecofriendly button on the Management Panel, you can
conserve energy.
Using the button When you press the ecofriendly button for 1 to 4 seconds, the front panel
port LEDs are disabled. You may use the button to turn off the LEDs when
you are not monitoring the switch. To turn the port LEDs on, press the
ecofriendly button for 1 to 4 seconds again. Toggling the LEDs does not
affect the network operations of the switch.
Using commands The management software on the switch has a command that blinks the
LEDs so that you can quickly and easily identify a specific unit among the
devices in an equipment rack. It is the findme command. The command
works on the switch even if you turned off the LEDs with the ecofriendly
button or by using the no ecofriendly led command.
Figure 8. ecofriendly button on the AT-x220-28GS switch
27
28
FAULT
POWER
USB
ON ACT
ERR
CLASS 1
LASER PRODUCT
CONSOLE
ecofriendly button
s
Note
The ecofriendly button does not control the Fault, Power or USB
LEDs.
Troubleshooting Before checking or troubleshooting the network connections to the ports
on the switch, you should always check to be sure that the LEDs are on by
either pressing the ecofriendly button or issuing the ecofriendly led and
no ecofriendly led commands in Global Configuration mode.
AT-x220-28GS Switch Installation Guide
15
Power supply
Each switch has an internal power supply with a single AC power supply
socket on the back panel. A power cord and a power cord retainer hook
are supplied with the switch. The power supply is not field replaceable.
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. E3
For the power requirements, see “Power specifications” on page 44.
Fans
Each switch has an internal fan.You cannot remove or replace these fans
in the field. The fan status is indicated with the Fault LED. See “Power and
Fault LEDs” on page 10 and Table 2 on page 11 for more information.
Chapter 1: Overview
16
AT-x220-28GS Switch Installation Guide
17
Chapter 2
Installation
This chapter contains the following sections:
“Reviewing safety precautions” on page 18
“Selecting a site for the switch” on page 21
“Unpacking the switch” on page 22
“Installing the switch on a table or a desktop” on page 23
“Removing the feet before installing the switch in an equipment
rack or on a wall” on page 25
“Installing the switch in an equipment rack” on page 26
“Installing the switch on a wall” on page 28
“Powering on the switch” on page 33
“Management software” on page 35
“Starting a local management session” on page 36
“Monitoring the initialization processes” on page 37
“Cabling the Network Ports” on page 41
“Installing SFP transceivers” on page 42
Chapter 2: Installation
18
Reviewing safety precautions
Please review the following safety precautions before you begin to install
the chassis or any of its components.
Note
The indicates that a translation of the safety statement is
available in a PDF document titled Translated Safety Statements.
Warning
To prevent electric shock, do not remove the cover. No user-
serviceable parts inside. This unit contains hazardous voltages and
should only be opened by a trained and qualified technician. To
avoid the possibility of electric shock, disconnect electric power to
the product before connecting or disconnecting the cables. E1
Warning
Do not work on equipment or cables during periods of lightning
activity. E2
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. E3
Warning
Class I Equipment. This equipment must be earthed. The power
plug must be connected to a properly wired earth ground socket
outlet. An improperly wired socket outlet could place hazardous
voltages on accessible metal parts. E4
Pluggable equipment: The socket outlet shall be installed near the
equipment and shall be easily accessible. E5
Caution
Air vents must not be blocked and must have free access to the
room ambient air for cooling. E6
Operating temperature: This product is designed for a maximum
ambient temperature of 50° degrees C. E7
AT-x220-28GS Switch Installation Guide
19
All countries: Install product in accordance with local and National
Electrical Codes. E8
Warning
Only trained and qualified personnel are allowed to install or replace
this equipment. E14
Circuit overloading: Consideration should be given to the
connection of the equipment to the supply circuit and the effect that
overloading of circuits might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern. E21
Warning
Mounting of the equipment in the rack should be such that a
hazardous condition is not created due to uneven mechanical
loading. E25
Warning
Use dedicated power circuits or power conditioners to supply
reliable electrical power to the device. E27
Warning
The chassis may be heavy and awkward to lift. Allied Telesis
recommends that you get assistance when mounting the chassis in
an equipment rack. E28
If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than
the room ambient temperature. Therefore, consideration should be
given to installing the equipment in an environment compatible with
the manufacturer’s maximum rated ambient temperature (Tmra).
E35
Caution
Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not
compromised. E36
Chapter 2: Installation
20
Warning
Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than
direct connections to the branch circuits (e.g., use of power strips).
E37
Caution
The unit does not contain serviceable components. Please return
damaged units for servicing. E42
Warning
The temperature of an operational SFP transceiver may exceed 70°
C(158° F) Exercise caution when removing or handling a transceiver
with unprotected hands. E43
Caution
An Energy Hazard exists inside this equipment. Do not insert hands
or tools into open chassis slots or plugs. E44
Warning
This equipment shall be installed in a Restricted Access location.
E45
AT-x220-28GS Switch Installation Guide
21
Selecting a site for the switch
You can install an AT-x220-28GS switch on a table or desktop, in a
standard 19-inch equipment rack, or on a wall.
Observe the following requirements when choosing a site for your switch:
If you are installing the switch on a table, verify that the table is
level and secure.
If you plan to install the switch in an equipment rack, verify that the
rack is safely secured and will not tip over. Devices in a rack should
be installed starting at the bottom, with the heavier devices near
the bottom of the rack.
If you are installing the switch on a wall, ensure that the wall is
sturdy enough to hold the switch’s weight. You may need to
position the switch so that it can be screwed into the wall’s framing
timber or an equivalent structural element.
The power outlet for the switch should be located near the unit and
should be easily accessible.
The site should provide for easy access to the ports on the front of
the switch. This will make it easier for you to connect and
disconnect cables, as well as view the switch’s LEDs.
The site should allow for adequate air flow around the unit and
through the cooling vents on the front and rear panels. (The
ventilation direction is from front to back.)
Do not place objects on top of the switch.
Do not expose the switch to moisture or water.
Ensure that the site is in a dust-free environment.
Do not install the switch in a wiring or utility box because it might
overheat and fail from inadequate airflow.
You should use dedicated power circuits or power conditioners to
supply reliable electrical power to the network devices.
Warning
Switches should not be stacked on a table or desktop. They could
present a physical safety hazard if you need to move or replace
switches. E91
Chapter 2: Installation
22
Unpacking the switch
To unpack the switch, perform the following procedure:
1. Remove all of the components from the shipped package.
Note
Store the packaging material in a safe location. You must use the
original shipping material if you need to return the unit to Allied
Telesis.
2. Place the switch on a level, secure surface.
3. Verify that the shipped package includes the following items:
One 2 m (6.6ft) local management cable
with RJ-45 (8P8C) and DB-9 (D-sub 9-pin)
One regional AC power cord
Power cord retaining clip
Two rack/wall mounting brackets
Eight bracket screws
Four anchors for concrete walls:
Length: 29.6 mm (1 1/8 in)
Diameter: 6.0 mm (0.25 in)
Four screws for wood or concrete walls:
Length: 31 mm (1/14 in)
Width: 4.3 mm (1/8 in)
Four rubber feet with push-in snap rivets
F
o
AT-x220-28GS Switch Installation Guide
23
Installing the switch on a table or a desktop
Here are the guidelines to selecting a suitable site for desktop or table use:
Review the procedure “Selecting a site for the switch” on page 21
to verify that the selected site is suitable for your switch.
The rubber feet included in the packaging should be attached to
the switch for table or desktop installation.
If your switch does not already have rubber feet fitted, fit these as follows:
1. Turn the switch over and place it on a table.
2. Remove the rubber feet, rivet pins and rivet housings from the
packaging.
Note
The feet are reusable. If they have been used previously, they may
be already assembled, with the rivet locked in place. To re-use
them, first push the rivets out of the feet. Then separate the rivet pin
and housing from each other, so that you can insert them as
described below.
3. Assemble the rivets by inserting the Pin into the Housing as shown in
Figure 9 on page 23.
Figure 9. Assembling the rivets
Insert all rivet pins into the rivet housings
Note
Do not press the pin all the way down to lock the rivet.If you do
engage the rivet lock, prise the pin out of the housing, so you can re-
assemble and re-use it.
Chapter 2: Installation
24
4. Insert the rivet through the hole in the feet as shown in Figure 10 on
page 24.
Figure 10. Inserting the assembled rivets into the hole in the foot
Insert all assembled rivets into the holes in the feet
5. Place the feet with the rivet inserted into the base holes on the switch.
Figure 11. Placing the feet with rivets on the switch
6. Push the feet firmly into holes on the base of the switch so that the
rivets lock the feet in place as shown in Figure 12 on page 24
Figure 12. Attaching the rubber feet to a switch
27
28
25
26
35179111315171921 23
46810122 16 18 2014
22 24
1000 LINK ACT 100 LINK ACT
AT-x220-28GS
FAULT
POWER
USB
ON ACT
ERR
CLASS1
LASER PRODUCT
CONSOLE
7. Turn the switch over again and place it on a flat, secure surface (such
as a desk or table), leaving ample space around the unit for ventilation.
AT-x220-28GS Switch Installation Guide
25
Removing the feet before installing the switch in an equipment rack or
on a wall
Before you install the switch in a 19-inch equipment rack or on a wall, you
need to remove the rubber feet, if they are attached to the base of the
switch. To do this, follow these steps:
1. Place the unit upside down on a level, secure surface.
2. Use a small flat-head screwdriver to pry the four rubber feet and their
rivets from the bottom of the switch. Figure 13 shows how to do this on
an AT-x220-28GS switch.
Figure 13. Removing the rubber feet and rivets from a switch
3. Turn the switch back over.
Note
The feet are reusable. To re-use them, first push the rivets out of the
feet. Then separate the rivet pin and housing from each other, so
that you can insert them as described in “Installing the switch on a
table or a desktop” on page 23.
Chapter 2: Installation
26
Installing the switch in an equipment rack
These instructions show you how to install the switch in an equipment
rack. The rack mount kit is included in the packaging and includes two
rack mount brackets and eight bracket screws.
To install one of these switches in a 19-inch equipment rack, follow these
steps:
1. Review the procedure “Selecting a site for the switch” on page 21 to
verify that the selected site is suitable for your switch.
2. If rubber feet are attached to the base of the switch, remove them
(Figure 13 on page 25).
3. Attach the two rack mount brackets to the sides of the switch using the
eight bracket screws that come with the rack mount kit provided. See
“Unpacking the switch” on page 22.
Figure 14. Attaching rack mount brackets to the AT-x220-28GS
switch
AT-x220-28GS Switch Installation Guide
27
4. Mount the switch in a 19-inch equipment rack using four equipment
rack screws (not supplied).
Figure 15. Mounting the AT-x220-28GS switch in an equipment rack
27
28
25
26
3 5
1 7 9 11 13 15 17 19 21 23
4 6 8 10122 1618 2014
22 24
1000 LINK ACT 100 LINK ACT
AT-x220-28GS
FAULT
POWER
USB
ON ACT
ERR
CLASS1
LASER PRODUCT
CONSOLE
Chapter 2: Installation
28
Installing the switch on a wall
These instructions show you how to install the switch on a wall. The rack/
wall mount brackets and screws are provided along with the screws for
securing the switch to a wall with wooden studs. Concrete anchors are
also provided for concrete walls.
Review the procedure “Selecting a site for the switch” on page 21 to verify
that the selected site is suitable for your switch.
Before you start, ensure that the wall is sturdy enough to hold the switch’s
weight. You may need to position the switch so that it can be screwed into
the wall’s framing timber or an equivalent structural element. The wall
location for the switch must provide adequate space to the front and back
panels so that you can service the unit, and for ventilation.
Wall guidelines Here are the guidelines to installing the switch on a wall:
You may install the switch on a wall that has wooden studs
You may install the switch on a concrete wall
You should not install the switch on a metal stud. Metal studs may
not be strong enough to safely support the device.
Tools and
materials
Here are the required tools and material for installing the switch on a wall:
Eight bracket screws (provided with the switch)
Two wall or equipment rack brackets (provided with the switch)
Four wall screws (provided with the switch for wood or concrete)
Four concrete anchors (provided with the switch)
Flat-head screwdriver (not provided)
Cross-head screwdriver (not provided)
Stud finder for a wooden wall, capable of identifying the middle of
wooden studs and hot electrical wiring (not provided)
Drill and a 1/4’’ carbide drill for a concrete wall (not provided)
Caution
The supplied screws and anchors may not be appropriate for all
walls. A qualified building contractor should determine the hardware
requirements for your wall prior to installing the switch.
AT-x220-28GS Switch Installation Guide
29
Positions of the
switch on a wall
The switch may be installed on the wall with the front panel on the left or
right with the brackets placed diagonally as shown in Figure 16.
Do not install the switch with the front panel on the top or the bottom.
Figure 16. Positioning the switch on the wall
Install the switch
on the wall
To install the switch on a wall, perform the following procedure:
1. If the rubber feet are attached to the bottom of the switch, remove
them with a screwdriver (Figure 13 on page 25), then turn the switch
back over.
2. Orient the brackets against the sides of the switch and secure them to
the unit with the 8 bracket screws included in the rack/wall mount kit.
You can either attach the brackets facing left or right as shown in
Figure 17 and Figure 18.
Chapter 2: Installation
30
Left facing Figure 17. Attaching wall mount brackets so that the switch is left
facing
Right facing Figure 18. Attaching wall mount brackets so that the switch right
facing
3. While another person holds the switch at the wall location, use a pencil
to mark the wall with the locations of the two screw holes for each
bracket. (Figure 19).
AT-x220-28GS Switch Installation Guide
31
Figure 19. Marking the screw holes from the brackets to the wall
4. While another person holds the switch at the marked wall location, use
a drill to make the holes for the two screws for each bracket. (Figure
20).
5. If you are installing the switch on a concrete wall, use the four concrete
anchors provided in the drill holes.
6. Use the four screws provided to secure the switch to the wall.
Figure 20. Securing the switch to the wall
Chapter 2: Installation
32
Powering on the switch
To power on the switch, perform the following procedure:
1. Attach the power cable hook and lift to the up position ready for the AC
power plug to be inserted, as shown in Figure 21, on the back of the
switch.
Figure 21. Attaching the AC power cable hook on the switch
2. Plug the power cord into the AC power connector, as shown in
Figure 22, on the back of the switch.
Figure 22. Plugging in the AC power cord on the Switch
AT-x220-28GS Switch Installation Guide
33
3. Plug the other end of the power cord into a wall outlet.
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. E3
Pluggable Equipment: The socket outlet shall be installed near the
equipment and shall be easily accessible. E5
4. Verify that the power LED is green. If the LED is off, see Chapter 3,
“Troubleshooting” on page 45.
The switch is now powered on and ready for network operations.
Chapter 2: Installation
34
Management software
The switches are shipped with the management software pre-installed.
The software provides a command line interface and a GUI (Graphical
User Interface) for in-band, over-the-network management.
In the unlikely event that the management software becomes corrupted or
damaged on the switch, you can download the software from the Allied
Telesis corporate web site and reinstall it on the switch. For instructions on
how to install new management software, see our Software Library at:
http://www.alliedtelesis.com/support
AT-x220-28GS Switch Installation Guide
35
Starting a local management session
This procedure requires a terminal or a terminal emulator program and the
management cable that comes with the switch. To start a local
management session on the switch, perform the following procedure:
1. Connect the RJ45 connector on the management cable to the console
port on the front panel of the switch, as shown below.
Figure 23. Connecting the management cable to the console port of
the x220 Series Switch
27
28
25
26
21 23
2224
FAULT
POWER
USB
ON ACT
ERR
CLASS 1
LASER PRODUCT
CONSOLE
2. Connect the other end of the cable to an RS-232 port on a terminal or
PC with a terminal emulator program.
3. Configure the terminal or terminal emulator program as follows:
Baud rate: 9600 bps (The baud rate of the Console Port is
adjustable from 1200 to 115200 bps. The default is 9600 bps.)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. If you have not already done so, power up the switch as described in
the previous steps.
Chapter 2: Installation
36
Monitoring the initialization processes
It takes about thirty seconds for the switch to initialize its management
software programs and features, and load the default configuration.
You may also monitor the bootup sequence by connecting a terminal or
computer that has a terminal emulator program, to the console port on the
master switch. You will see the messages from Figure 24 below to Figure
26 on page 40.
Figure 24. Switch initialization messages
Verifying release... OK
Booting...
Starting base/first... [ OK ]
Mounting virtual filesystems... [ OK ]
______________ ____
/\ \ / /______\
/ \ \_ __/ /| ______ |
/ \ | | / | ______ |
/ \ \ / / \ ____ /
/______/\____\ \/ /____________/
Allied Telesis Inc.
AlliedWare Plus (TM) v0.0.0
Current release filename:x220-5.4.8.rel
Built: Fri Mar 23 07:06:12 UTC 2018
Mounting static filesystems... [ OK ]
Attaching to /dev/mtd0... [ OK ]
Mounting file system... [ OK ]
Checking for last gasp debug output... [ OK ]
Checking NVS filesystem... [ OK ]
Mounting NVS filesystem... [ OK ]
Initializing random number generator... [ OK ]
Starting base/hwrandom... [ OK ]
Starting base/dbus... [ OK ]
Starting base/linux... [ OK ]
Starting base/syslog... [ OK ]
Starting base/loopback... [ OK ]
Starting base/poe_done... [ OK ]
Starting base/portmapper... [ OK ]
Received event syslog.done
Starting base/modules... [ OK ]
AT-x220-28GS Switch Installation Guide
37
Figure 25. Switch initialization messages (continued)
Received event modules.done
Starting base/reboot-stability... [ OK ]
Checking system reboot stability... [ OK ]
Starting base/apteryx... [ OK ]
Starting base/crond... [ OK ]
Starting base/appmond... [ OK ]
Starting base/clockcheck... [ OK ]
Starting base/inet... [ OK ]
Received event apteryx.done
Starting hardware/early_host_info... [ OK ]
Starting base/eventwatch... [ OK ]
Starting base/alfred... [ OK ]
Starting network/kermond... [ OK ]
Starting base/apteryx-sync... [ OK ]
Starting base/logconf... [ OK ]
Received event apteryx-sync.done
Starting hardware/plugman... [ OK ]
Starting hardware/openhpi... [ OK ]
Starting hardware/timeout... [ OK ]
Received event board.inserted
Starting hardware/hardware-done... [ OK ]
Received event hardware.done
Starting network/startup... [ OK ]
Starting base/external-media... [ OK ]
Received event hostcfg.done
Starting network/licd... [ OK ]
Starting network/stackd... [ OK ]
Starting network/election.timeout... [ OK ]
Starting network/corosync... [ OK ]
Received event network.enabled
Initializing HA processes:
atmf_agentd, exfx, hostd, auth, imiproxyd, lldpd, nsm
sflowd, hsl, irdpd, lacp, mstp, ripd, rmon
atmfd, cntrd, epsr, imi, loopprot, ripngd, udldd
Received event network.initialized
Chapter 2: Installation
38
Figure 26. Switch initialization messages (continued)
Assigning Active Workload to HA processes:
hsl, irdpd, lacpd, loopprotd, mstpd, nsm, ripd
rmond, sflowd, authd, epsrd, lldpd, imi, imiproxyd
Received event network.activated
Loading default configuration
Warning: flash:/default.cfg does not exist, loading factory defaults.
.
done!
Received event network.configured
awplus login:
AT-x220-28GS Switch Installation Guide
39
Cabling the Network Ports
Observe the following guidelines before installing SFP transceivers on the
switch.
The transceivers are hot-swappable. You can install them while the
switch is powered on.
For a list of supported transceivers, refer to the product data sheet
on the Allied Telesis web site.
The operational specifications and fiber optic cable requirements of
the transceivers are provided in the documents included with the
devices.
You should install a transceiver before connecting its fiber optic
cable.
Unnecessary removal and insertion of a transceiver can lead to
premature failure.
Caution
Transceivers can be damaged by static electricity. Be sure to
observe all standard electrostatic discharge (ESD) precautions, such
as wearing an anti-static wrist strap, to avoid damaging the devices.
E92
Chapter 2: Installation
40
Installing SFP transceivers
To install an SFP transceiver, perform the following procedure:
Note
The transceiver can be hot-swapped; you do not need to power off
the switch to install a transceiver. However, always remove the
cables before removing the transceiver.
Note
You should always install the transceiver before connecting the fiber
optic cables to it.
1. Remove the transceiver from its shipping container and store the
packaging material in a safe location.
Warning
An SFP transceiver can be damaged by static electricity. Be sure to
observe all standard electrostatic discharge (ESD) precautions,
such as wearing an anti-static wrist strap, to avoid damaging the
transceiver.
2. Position the SFP transceiver with the Allied Telesis label facing up for
the top SFP slots. Position the SFP transceiver with the Allied Telesis
label facing down for the bottom SFP slots.
3. Gently slide the transceiver into the SFP slot until it clicks into place as
shown in Figure 27.
Figure 27. Inserting an SFP transceiver into an SFP slot
27
28
25
26
FAULT
POWER
USB
ON ACT
ERR
CLASS 1
LASER PRODUCT
CONSOLE
AT-x220-28GS Switch Installation Guide
41
4. Verify that the handle on the transceiver is in the upright position, as
shown in Figure 28. This secures the transceiver and prevents it from
being dislodged from the slot. If the transceiver is in a bottom slot verify
the handle is in the downright position.
Figure 28. Positioning the SFP handle in the upright position
27
28
25
26
FAULT
POWER
USB
ON ACT
ERR
CLASS 1
LASER PRODUCT
CONSOLE
SFP Transceiver
Handle
5. Eject SFP transceivers, as shown in Figure 29. First lower the SFP
transceiver handle, then gently remove the SFP transceiver. If the
transceiver is in a bottom slot, then raise the handle.
Figure 29. Ejecting an SFP transceiver after lowering the SFP handle
to the downwards position
27
28
25
26
FAULT
POWER
USB
ON ACT
ERR
CLASS 1
LASER PRODUCT
CONSOLE
6. Repeat steps 2 through 6 to install an additional SFP transceiver.
Note
Unnecessary removal and insertion of an SFP transceiver can lead
to premature failure.
For information on the cable specifications of the SFP, consult the
documentation shipped with the SFP.
Chapter 2: Installation
42
AT-x220-28GS Switch Installation Guide
45
Chapter 3
Troubleshooting
This chapter contains information on how to troubleshoot the switch if a
problem occurs.
Note
For further assistance, please contact Allied Telesis Technical
Support at www.alliedtelesis.com/support.
Problem 1: The power LED on the front of the switch is off.
Solutions: The unit is not receiving power. Try the following:
Verify that the power cord is securely connected to the power
source and to the AC connector on the back panel of the switch.
Verify that the power outlet has power by connecting another
device to it.
Try connecting the unit to another power source.
Try a different power cord.
Verify that the voltage from the power source is within the required
levels for your region.
Problem 2: All of the port LEDs are off even though the ports are
connected to active network devices.
Solution: The switch is probably operating in low power mode. To toggle
on the LEDs, press the ecofriendly button on the front panel for 1 to 4
seconds.
Problem 3: The Link/Activity/Speed LED for an SFP transceiver is off.
Solutions: The fiber optic port on the transceiver is unable to establish a
link to a network device. Try the following:
Verify that the remote network device connected to the fiber optic
port is operating properly.
Verify that the fiber optic cable is securely connected to the port on
the media converter channel and to the port on the remote network
device.
Check that the SFP module is fully inserted in the slot.
Verify that the operating specifications of the fiber optic ports on
the SFP transceiver and the remote network device are
compatible.
Chapter 3: Troubleshooting
46
Verify that the correct type of fiber optic cabling is being used.
Verify that the port is connected to the correct fiber optic cable.
This is to eliminate the possibility that the port is connected to the
wrong remote network device, such as a powered off device.
Try connecting another network device to the fiber optic port using
a different cable. If the port is able to establish a link, then the
problem is with the cable or with the other network device.
Use the switch’s management software to verify that the port is
enabled.
If the remote network device is a management device, use its
management firmware to determine whether its port is enabled.
Test the attenuation on the fiber optic cable with a fiber optic tester
to determine whether the optical signal is too weak (sensitivity) or
too strong (maximum input power).
Problem 4: The switch functions intermittently.
Solutions: Check the system hardware status through the management
software:
Use the show system environment command in the Privileged
Exec mode to verify that the input voltage from the power source to
the switch is stable and within the approved operating range. The
unit will shut down if the input voltage fluctuates above or below
the approved operating range.
Use the show system environment command in the Privileged
Exec mode to verify that the fan is operating correctly.
Verify that the location of the switch allows for adequate airflow.
The unit will shut down if it is in danger of overheating.
Problem 5: A port’s Link/Activity/Speed LED is blinking.
Solutions: The link between the port and the network device is
intermittent. Try the following:
Connect another network device with a different cable to the port. If
the Link LED remains steady on, then the problem is with the
original cable or the network device.
If the problem is with an SFP transceiver, check that the
transceiver is fully inserted in the slot.
AT-x220-28GS Switch Installation Guide
47
Appendix A
Technical specifications
This appendix describes the technical specifications of an x220 series
switch.
Physical specifications
Dimensions
TABLE 5. CHASSIS DIMENSIONS
Model W x D x H mm (in)
AT-x220-28GS 341 mm x 231mm x 44mm
(13.42 in x 9.10 in x 1.73 in)
Weight
TABLE 6. CHASSIS WEIGHT
Model Weight
AT-x220-28GS 4.3 kg (9.47 lb)
Appendix A: Technical specifications
48
Environmental specifications
TABLE 7. ENVIRONMENTAL SPECIFICATIONS
Operating temperature 0° C to +50° C (32° F to 122° F)
Storage temperature -25° C to 70° C (-4° F to 158° F)
Operating humidity < 90% non-condensing
Storage humidity < 95% non-condensing
Operating altitude range Up to 3,000 m (9,842 ft)
Power specifications
TABLE 8. INPUT SUPPLY VOLTAGE
Model Input supply voltage
AT-x220-28GS 100-240 VAC, 50 - 60 Hz, 0.60A maximum
TABLE 9. POWER SPECIFICATIONS
Model Power budget Maximum power
consumption
AT-x220-28GS N/A 75 W
AT-x220-28GS Switch Installation Guide
49
Electrical safety and electromagnetic certifications
TABLE 10. SAFETY AND ELECTROMAGNETIC EMISSIONS CERTIFICATIONS
EMC EN 55024
EN 55032 Class A
EN 61000-3-2
EN 61000-3-3
FCC Part 15 (CFR 47) Class A
VCCI Class A
CISPR 22 Class A
ICES-003
Environmental
compliance
RoHS
WEEE
Electrical safety EN 60950-1 (edition 2)
IEC 60950-1 (edition 2)
UL 60950-1 (edition 2)
C-UL-US
TUV-T-Mark
Laser safety EN 60825
Regulatory
Compliance
RCM
CE
Appendix A: Technical specifications
50
Connectors and port pinouts for the console port
This section lists the connectors and connector pinouts for the
management console port.
Figure 30 illustrates the pin layout for an RJ45 connector for the console
port.
Figure 30. RJ45 connector and port pin layout
Table 11 lists the RJ-45 style serial consol port pin signals.
Table 11. RJ-45 Style Serial Consol Port Pin Signals
Pin Signal
1Looped to pin 8
2Looped to pin 7
3Transmit Data x220-28GS Tx Output pin
4Ground
5Ground
6Receive Data x220-28GS Rx Input pin
7Looped to pin 2