Table of Contents
- Notices
- Chapter 1: Product introduction
- Chapter 2: Hardware setup
- Chapter 3: Installation options
- Chapter 4: Motherboard Info
- Chapter 5: BIOS setup
- 5.1 Managing and updating your BIOS
- 5.2 BIOS setup program
- 5.3 Main menu
- 5.4 Advanced menu
- 5.4.1 CPU Configuration
- 5.4.2 PCH-IO Configuration
- 5.4.3 SATA Configuration
- 5.4.4 System Agent (SA) Configuration
- 5.4.5 PCI Subsystem Settings
- 5.4.6 USB Configuration
- 5.4.7 TPM
- 5.4.8 ACPI Settings
- 5.4.9 WHEA Support
- 5.4.10 NCT6779D Super IO Configuration
- 5.4.11 Intel Server Platform Services
- 5.4.12 Onboard LAN Configuration
- 5.4.13 MIO Card Configuration
- 5.4.14 Serial Port Console Redirection
- 5.4.15 Runtime Error Logging Support
- 5.4.16 APM
- 5.4.17 Network Stack
- 5.4.18 Intel RC Drivers Version Detail
- 5.5 Event Logs menu
- 5.6 Boot menu
- 5.7 Monitor menu
- 5.8 Security
- 5.9 Tool menu
- 5.10 Exit menu
- Chapter 6: RAID configuration
- Chapter 7: Driver installation
ASUS RS300-E8-RS4 User Manual
Displayed below is the user manual for RS300-E8-RS4 by ASUS which is a product in the Server Barebones category. This manual has pages.
Related Manuals
1U Rackmount Server
RS300-E8 Series
User Guide
RS300-E8-PS4
RS300-E8-RS4
ii
Copyright © 2013 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language in any form or by any means,
except documentation kept by the purchaser for backup purposes, without the express written permission
of ASUSTeK COMPUTER INC. (“ASUS”).
ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not
limited to the implied warranties or conditions of merchantability or tness for a particular purpose. In no
event shall ASUS, its directors, ofcers, employees, or agents be liable for any indirect, special, incidental,
or consequential damages (including damages for loss of prots, loss of business, loss of use or data,
interruption of business and the like), even if ASUS has been advised of the possibility of such damages
arising from any defect or error in this manual or product.
Specications and information contained in this manual ae furnished for informational use only, and are
subject to change at any time without notice, and should not be construed as a commitment by ASUS.
ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual,
including the products and software described in it.
Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless
such repair, modication of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identication or explanation and to the
owners’ benet, without intent to infringe.
E8115
First Edition
March 2013
iii
Contents
Notices ........................................................................................................ vii
REACH .......................................................................................... vii
Safety information .................................................................................... viii
Australia statement notice .................................................................ix
About this guide .......................................................................................... x
Chapter 1: Product introduction
1.1 System package contents ........................................................... 1-2
1.2 Serial number label ...................................................................... 1-3
1.3 Systemspecications ................................................................. 1-4
1.4 Front panel features ..................................................................... 1-6
1.5 Rear panel features ...................................................................... 1-7
1.6 Internal features ........................................................................... 1-8
1.7 LED information ........................................................................... 1-9
1.7.1 Front panel LEDs ............................................................ 1-9
1.7.2 LAN (RJ-45) LEDs ........................................................ 1-10
1.7.3 HDD status LED ............................................................ 1-10
Chapter 2: Hardware setup
2.1 Chassis cover ............................................................................... 2-2
2.2 Central Processing Unit (CPU) ................................................... 2-3
2.2.1 Installing the CPU ........................................................... 2-3
2.2.2 Installing the CPU heatsink and airduct .......................... 2-6
2.3 System memory ........................................................................... 2-8
2.3.1 Overview ......................................................................... 2-8
2.3.2 Memory Congurations ................................................... 2-8
2.3.3 Installing a DIMM ............................................................ 2-9
2.4 Hard disk drives ......................................................................... 2-10
2.5 Expansion slot ............................................................................ 2-12
2.5.1 Installing an expansion card to the riser card bracket ... 2-12
2.5.2 Conguring an expansion card ..................................... 2-14
2.6 Cable connections ..................................................................... 2-15
2.7 SATA/SAS backplane cabling ................................................... 2-16
iv
Contents
2.8 Removable/optional components ............................................. 2-17
2.8.1 System fans .................................................................. 2-17
2.8.2 Installing ASUS PIKE RAID card (optional) .................. 2-18
2.8.3 Installing ASMB7 series management board (optional) 2-20
2.8.4 Installing the SSD cage (optional) ................................. 2-21
Chapter 3: Installation options
3.1 Friction Rail Kit Installation Guide ............................................. 3-2
3.1.1 Attaching the xing latches to the server ........................ 3-2
3.2 Installing optional ball-bearing rail kit items ............................. 3-5
3.2.1 Attaching the rails to the server ...................................... 3-5
3.2.2 Attaching the rack rails .................................................... 3-6
3.2.3 Mounting the server to the rack ...................................... 3-7
Chapter 4: Motherboard Info
4.1 Motherboard layout ...................................................................... 4-2
4.2 Jumpers ........................................................................................ 4-4
4.3 Internal connectors ...................................................................... 4-7
4.4 Internal LEDs .............................................................................. 4-19
Chapter 5: BIOS setup
5.1 Managing and updating your BIOS ............................................ 5-2
5.1.1 ASUS CrashFree BIOS 3 utility ...................................... 5-2
5.1.2 ASUS EzFlash Utility ...................................................... 5-3
5.1.3 BUPDATER utility............................................................ 5-4
5.2 BIOS setup program .................................................................... 5-6
5.2.1 BIOS menu screen .......................................................... 5-7
5.2.2 Menu bar ......................................................................... 5-7
5.2.3 Menu items ..................................................................... 5-8
5.2.4 Submenu items ............................................................... 5-8
5.2.5 Navigation keys ............................................................... 5-8
5.2.6 General help ................................................................... 5-8
5.2.7 Conguration elds ......................................................... 5-8
5.2.8 Pop-up window ............................................................... 5-8
5.2.9 Scroll bar ......................................................................... 5-8
v
Contents
5.3 Main menu .................................................................................... 5-9
5.3.1 System Date .................................................................. 5-9
5.3.2 System Time ................................................................... 5-9
5.4 Advanced menu ......................................................................... 5-10
5.4.1 CPU Conguration .........................................................5-11
5.4.2 PCH-IO Conguration ................................................... 5-14
5.4.3 SATA Conguration ....................................................... 5-15
5.4.4 System Agent (SA) Conguration ................................. 5-16
5.4.5 PCI Subsystem Settings ............................................... 5-18
5.4.6 USB Conguration ........................................................ 5-20
5.4.7 TPM .............................................................................. 5-21
5.4.8 ACPI Settings ................................................................ 5-21
5.4.9 WHEA Support .............................................................. 5-22
5.4.10 NCT6779D Super IO Conguration .............................. 5-22
5.4.11 Intel Server Platform Services ...................................... 5-23
5.4.12 Onboard LAN Conguration .......................................... 5-24
5.4.13 MIO Card Conguration ................................................ 5-24
5.4.14 Serial Port Console Redirection .................................... 5-25
5.4.15 Runtime Error Logging Support .................................... 5-27
5.4.16 APM .............................................................................. 5-27
5.4.17 Network Stack ............................................................... 5-28
5.4.18 Intel RC Drivers Version Detail ..................................... 5-28
5.5 Event Logs menu ....................................................................... 5-29
5.6 Boot menu .................................................................................. 5-30
5.7 Monitor menu ............................................................................. 5-33
5.8 Security ....................................................................................... 5-34
5.9 Tool menu ................................................................................... 5-37
5.10 Exit menu .................................................................................... 5-37
vi
Contents
Chapter6: RAIDconguration
6.1 Setting up RAID ............................................................................ 6-2
6.1.1 RAID denitions .............................................................. 6-2
6.1.2 Installing hard disk drives ................................................ 6-3
6.1.3 Setting Jumpers .............................................................. 6-3
6.1.4 Setting the RAID mode in BIOS ...................................... 6-3
6.1.5 RAID conguration utilities .............................................. 6-3
6.2 Intel® Rapid Storage Technology enterprise
SATA Option ROM Utility ............................................................. 6-4
6.2.1 Creating a RAID set ........................................................ 6-5
6.2.2 Deleting a RAID set ........................................................ 6-7
6.2.3 Resetting disks to Non-RAID .......................................... 6-8
6.2.4 Exiting the Intel® Rapid Storage Technology enterprise
SATA Option ROM utility ................................................. 6-9
6.2.5 Rebuilding the RAID ....................................................... 6-9
6.2.6 Setting the Boot array in the BIOS Setup Utility .............6-11
6.3 Intel® Rapid Storage Technology enterprise (Windows) ........ 6-12
6.3.1 Creating a RAID set ...................................................... 6-13
6.3.2 Changing a Volume Type .............................................. 6-15
6.3.3 Deleting a volume ......................................................... 6-16
6.3.4 Preferences ................................................................... 6-17
Chapter 7: Driver installation
7.1 RAID driver installation ............................................................... 7-2
7.1.1 Creating a RAID driver disk ............................................ 7-2
7.1.2 Installing the RAID controller driver ................................ 7-4
7.2 Management applications and utilities installation .................. 7-6
7.3 Running the Support DVD .......................................................... 7-6
7.4 Installing the LAN driver ............................................................ 7-14
7.5 Installing the VGA driver ........................................................... 7-19
ASUS contact information .......................................................................A-1
vii
Notices
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with manufacturer’s instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Canadian Department of Communications Statement
This digital apparatus does not exceed the Class A limits for radio noise emissions
from digital apparatus set out in the Radio Interference Regulations of the Canadian
Department of Communications.
This Class A digital apparatus complies with Canadian ICES-003.
WARNING! The use of shielded cables for connection of the monitor to the
graphics card is required to assure compliance with FCC regulations. Changes
or modications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.
REACH
Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of
Chemicals) regulatory framework, we publish the chemical substances in our products
at ASUS REACH website at http://csr.asus.com/english/REACH.htm.
viii
Safety information
Electrical Safety
• Before installing or removing signal cables, ensure that the power cables for the
system unit and all attached devices are unplugged.
• To prevent electrical shock hazard, disconnect the power cable from the electrical
outlet before relocating the system.
• When adding or removing any additional devices to or from the system, ensure
that the power cables for the devices are unplugged before the signal cables
are connected. If possible, disconnect all power cables from the existing system
before you add a device.
• If the power supply is broken, do not try to x it by yourself. Contact a qualied
service technician or your dealer.
Operation Safety
• Any mechanical operation on this server must be conducted by certied or
experienced engineers.
• Before operating the server, carefully read all the manuals included with the server
package.
• Before using the server, ensure all cables are correctly connected and the power
cables are not damaged. If any damage is detected, contact your dealer as soon
as possible.
• To avoid short circuits, keep paper clips, screws, and staples away from
connectors, slots, sockets and circuitry.
• Avoid dust, humidity, and temperature extremes. Place the server on a stable
surface.
Lithium-Ion Battery Warning
CAUTION! Danger of explosion if battery is incorrectly replaced. Replace
only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
CD-ROM Drive Safety Warning
CLASS 1 LASER PRODUCT
Heavy System
CAUTION! This server system is heavy. Ask for assistance when moving or
carrying the system.
This product is equipped with a three-wire power cable and plug for the user’s
safety. Use the power cable with a properly grounded electrical outlet to avoid
electrical shock.
ix
DO NOT throw the motherboard in municipal waste. This product has been
designed to enable proper reuse of parts and recycling. This symbol of the
crossed out wheeled bin indicates that the product (electrical and electronic
equipment) should not be placed in municipal waste. Check local regulations for
disposal of electronic products.
DO NOT throw the mercury-containing button cell battery in municipal waste.
This symbol of the crossed out wheeled bin indicates that the battery should not
be placed in municipal waste.
Australia statement notice
From 1 January 2012 updated warranties apply to all ASUS products, consistent
with the Australian Consumer Law. For the latest product warranty details please
visit http://support.asus.com. Our goods come with guarantees that cannot be
excluded under the Australian Consumer Law. You are entitled to a replacement or
refund for a major failure and compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a major
failure.
If you require assistance please call ASUS Customer Service 1300 2787 88 or visit
us at http://support.asus.com
x
About this guide
Audience
This user guide is intended for system integrators, and experienced users with at
least basic knowledge of conguring a server.
Contents
This guide contains the following parts:
1. Chapter 1: Product introduction
This chapter describes the general features of the server, including sections
on front panel and rear panel specications.
2. Chapter 2: Hardware setup
This chapter lists the hardware setup procedures that you have to perform
when installing or removing system components.
3. Chapter 3: Installation options
This chapter describes how to install optional components into the barebone
server.
4. Chapter 4: Motherboard information
This chapter gives information about the motherboard that comes with the
server. This chapter includes the motherboard layout, jumper settings, and
connector locations.
5. Chapter 5: BIOS information
This chapter tells how to change system settings through the BIOS Setup
menus and describes the BIOS parameters.
6. Chapter6:RAIDconguration
This chapter tells how to change system settings through the BIOS Setup
menus. Detailed descriptions of the BIOS parameters are also provided.
7 Chapter 7: Driver installation
This chapter provides instructions for installing the necessary drivers for
different system components.
xi
References
Refer to the following sources for additional information, and for product and
software updates.
1. ASUS Server Web-based Management (ASWM) user guide
This manual tells how to set up and use the proprietary ASUS server
management utility.
2. ASUS websites
The ASUS websites worldwide provide updated information for all ASUS
hardware and software products. Refer to the ASUS contact information.
Conventions
To ensure that you perform certain tasks properly, take note of the following
symbols used throughout this manual.
Typography
Bold text Indicates a menu or an item to select.
Italics
Used to emphasize a word or a phrase.
<Key> Keys enclosed in the less-than and greater-than
sign means that you must press the enclosed key.
Example: <Enter> means that you must press
the Enter or Return key.
<Key1>+<Key2+<Key3> If you must press two or more keys simultaneously,
the key names are linked with a plus sign (+).
Example: <Ctrl>+<Alt>+<Del>
Command Means that you must type the command
exactly as shown, then supply the required
item or value enclosed in brackets.
Example: At the DOS prompt, type the
command line: format A:/S
DANGER/WARNING: Information to prevent injury to yourself when
trying to complete a task.
CAUTION: Information to prevent damage to the components when
trying to complete a task.
NOTE: Tips and additional information to help you complete a task.
IMPORTANT: Instructions that you MUST follow to complete a task.
xii
1-
This chapter describes the general
features of the chassis kit. It includes
sections on front panel and rear panel
specications.
Chapter 1
Product introduction
Chapter 1: Product introduction1-2
*ASUS System Web-based Management
If any of the above items is damaged or missing, contact your retailer.
1.1 System package contents
Check your system package for the following items.
Model Name RS300-E8-PS4, RS300-E8-RS4
Chassis ASUS R10E 1U Rackmount Chassis
Motherboard ASUS P9D-C/4L Server Board
Component 1 x 400W Single Power Supply (RS300-E8-PS4)
1 x 450W Redundant Power Supply (RS300-E8-RS4)
4 x Hot-swap 3.5” HDD trays
1 x SAS/SATA Backplane (BP4LX-R10A)
1 x PCI Riser Card (RE16LE8R-R10A)
1 x Front I/O Board (FPB-R20D)
4 x System Fans (40mm x 28mm)
Accessories 1 x RS300-E8 Series User’s Guide
1 x ASWM* User’s Guide
1 x ASMB7 User’s Guide (if ASMB7-iKVM is selected)
1 x RS300-E8 Series Support DVD
1 x ASWM* DVD
1 x ASMB7 DVD (if ASMB7-iKVM is selected)
1 x Bag of Screws
1 x AC Power Cable (RS300-E8-PS4)
2 x AC Power Cable (RS300-E8-RS4)
Optional
Items
1 x CPU Heatsink
ASUS ASMB7-iKVM Remote management card
DVD-ROM/DVD-RW
Second 450W Redundant Power Supply Module (RS300-E8-RS4)
1 x Friction Rail Kit
ASUS RS300-E8 Series 1-3
1.2 Serial number label
Before requesting support from the ASUS Technical Support team, you must
take note of the product’s serial number containing 14 characters such as
xxS0xxxxxxxxxx shown as the gure below. With the correct serial number of the
product, ASUS Technical Support team members can then offer a quicker and
satisfying solution to your problems.
xxS0xxxxxxxxxx
RS300-E8-PS4, RS300-E8-RS4
Chapter 1: Product introduction1-4
1.3 Systemspecications
The ASUS RS300-E8 Series is a 1U barebone server system featuring the
ASUS P9D-C/4L Server Board. The server supports Intel® LGA1150 Intel®
Xeon® E3-1200 Processor v3 plus other latest technologies through the chipsets
onboard.
(continued on the next page)
Model Name RS300-E8-PS4, RS300-E8-RS4
Processor Support / System
Bus
1 x Socket LGA1150
Intel® Xeon® Processor E3-1200 v3 Family
Core Logic Intel® C224 Chipset
Memory
Total Slots 4 (2 Channels)
Capacity Maximum up to 32GB (UDIMM)
Memory Type DDR3 1333/1600 ECC UDIMM
Memory Size 2GB, 4GB, 8GB (UDIMM)
Expansion
Slots (follow
SSI Location #)
Total PCI/PCI-E
Slots 2
Slot Type 1 x PCI-E x16 (x8 Gen3 link) (Full-Height/HL))
1 x PCI-E x8 (x4 Gen3 link) (Full-Height/HL)
Additional Slot
11 x PIKE Slot for Storage enhancement
Storage
SATA Controller
Intel® C224:
- 2 x SATA 3Gb/s ports
- 4 x SATA 6Gb/s ports
- Intel® Rapid Storage Technology Enterprise (RSTe)
supports software RAID 0, 1, 10, & 5 (Windows®)
SAS Controller
Optional kits:
ASUS PIKE 2008 8-port SAS 6G RAID Card
ASUS PIKE 2108-32PD 8-port SAS 6G RAID Card
ASUS PIKE 2308 8-port SAS 6G RAID Card
HDD Bays
I = internal
A or S = hot-
swappable
4 x Hot-swap 3.5 in. HDD Bays
2 x SSD Bays (Optional)
Networking LAN 4 x Intel® I210 + 1 x Management LAN
Graphic VGA Aspeed AST2300 32MB
ASUS RS300-E8 Series 1-5
*Specicationsaresubjecttochangewithoutnotice.
Model Name RS300-E8-PS4 RS300-E8-RS4
Onboard I/O Connectors
1 x External Serial Port
5 x RJ-45 ports (1 for ASMB7-iKVM)
4 x USB 3.0 ports (Front x 2, Rear x 2)
2 x USB 2.0 ports (Rear x 2)
2 x VGA port (Front x 1, Rear x 1)
1 x Internal A-Type USB Port
1 x PS/2 keyboard/mouse combo port
OS Support
Windows® Server 2012
Windows® 8 64-bit
Windows® Server 2008 Enterprise SP2 64-bit
Windows® Server 2008 Enterprise R2 SP1 64-bit
RedHat® Enterprise Linux AS 5.8/6.3 U8 64-bit Centos
5.8/6.2/6.3 64-bit
(Subject to change without any notice)
Management
Solution
Software ASWM Enterprise
Out of Band
Remote
Management
Optional ASMB7-iKVM for KVM-over-IP
Dimension (HH x WW x DD) 615mm x 444mm x 43.4mm
Net Weight Kg
(CPU, DRAM & HDD not
included)
16 Kg
Power Supply
Single 400W 80PLUS
Gold Power Supply 1+1 Redundant 450W
80PLUS Gold Power
Supply
Power Rating 100-240VAC, 6.3-3A,
60-50Hz, Class I
100-127/200-240Vac,
8/4A, 47-63Hz, Class I
Environment
Operating temperature:
10oC – 40oC
Non operation temperature:
-40oC – 70oC
Non operation humidity:
20% – 90% (Non condensing)
Chapter 1: Product introduction1-6
1.4 Front panel features
The barebone server displays a simple yet stylish front panel with easily accessible
features. The power and reset buttons, LED indicators, and USB port for each
Node are located on the front panel.
Refer to section 1.7.1 Front panel LEDs for the LED descriptions.
Turn off the system power and detach the power supply before removing or
replacing any system component.
Hot-swap HDD bays
Slim-type optical drive
(Optional)
Rack screw Rack screw
USB 3.0 ports
LAN4 LED
LAN3 LED
HDD Access LED
Message LED
Power button
Reset button
Locate switch
Hot-swap HDD bays
LAN2 LED
LAN1 LED
VGA port
Asset tag
The Asset tag is a simple but useful device that is conveniently located on the front panel of
the server that you can pull out or easily slide back in. It has a piece of paper that allows you
to write down important information about to the server.
Asset tag
ASUS RS300-E8 Series 1-7
1.5 Rear panel features
The rear panel includes the expansion slots, system power sockets, and rear fans.
The I/O shields with openings for the rear panel connectors on the motherboard
are also placed in the real panel.
The ports for the USB, VGA, and Gigabit LANs do not appear on the rear panel
if the motherboards are not present.
VGA port
USB 3.0 ports
LAN port 5*
PS/2 keyboard/mouse port
Gigabit LAN port 3
Gigabit LAN port 4
Gigabit LAN port 1
Gigabit LAN port 2
USB 2.0 ports
* This port is for ASUS ASMB7-iKVM controller card only.
VGA port
USB 3.0 ports
LAN port 5*
PS/2 keyboard/mouse port
Gigabit LAN port 3
Gigabit LAN port 4
Gigabit LAN port 1
Gigabit LAN port 2
USB 2.0 ports
RS300-E8-RS4
RS300-E8-PS4
Chapter 1: Product introduction1-8
1.6 Internal features
The barebone server includes the basic components as shown.
1. Power supply and power
fan
2. PCI Express slot Riser Card
3. ASUS P9D-C/4L Server
Boards
4. System fans
5. SAS / SATA backplane
(hidden)
6. HDD tray 1—Connect to
SATA1 port
7. HDD tray 2—Connect to
SATA2 port
8. HDD tray 3—Connect to
SATA3 port
9. HDD tray 4—Connect to
SATA4 port
10. Front I/O boards (hidden)
11. Slim-type optical drive
12. SSD Cage (Optional)
13. Asset Tag
The barebone server does not include a oppy disk drive drive. Connect a USB
oppy disk drive to any of the USB ports on the front or rear panel if you need to
use a oppy disk.
*WARNING
HAZARDOUS MOVING PARTS
KEEP FINGERS AND OTHER BODY PARTS AWAY
Turn off the system power and detach the power supply before removing or
replacing any system component.
1
2
3
4 4 4 4
10
96 7 8
11
5
12
12
13
ASUS RS300-E8 Series 1-9
1.7 LED information
1.7.1 Front panel LEDs
LED Icon Display
status Description
Power LED ON System power ON
HDD
Access
LED
OFF No activity
Blinking Read/write data into the HDD
Message
LED
OFF System is normal; no incoming event
ON
1. Without ASMB7-iKVM installed: CPU over-heated
2. With ASMB7-iKVM installed: a hardware monitor event is
indicated
LAN LEDs
OFF No LAN connection
Blinking LAN is transmitting or receiving data
ON LAN connection is present
Location
LED
ON Location switched is pressed.
OFF Normal status.
(Press the location switch again to turn off.)
LAN4 LED
LAN3 LED
HDD Access LED
Message LED
Location LED
LAN2 LED
LAN1 LED
Power LED
3
4
Chapter 1: Product introduction1-10
1.7.2 LAN (RJ-45) LEDs
ACT/LINK LED SPEED LED
Status Description Status Description
OFF No link OFF 10 Mbps connection
GREEN Linked ORANGE 100 Mbps connection
BLINKING Data activity GREEN 1 Gbps connection
1.7.3 HDD status LED
HDD status LED
SATA HDD LED Description
GREEN This installed Serial ATA HDD is in good condition
OFF HDD failure or no HDD is installed
SPEED LED
ACT/LINK LED
2-
This chapter lists the hardware setup
procedures that you have to perform
when installing or removing system
components.
Chapter 2
Hardware setup
Chapter 2: Hardware setup2-2
2.1 Chassis cover
Removing the rear cover
1. Locate and remove the front side screws.
3. Firmly hold the cover and slide it
toward the rear panel for about half
an inch until it is disengaged from
the chassis.
4. Lift the cover from the chassis.
5. To recover the rear cover, reverse
step 1 to 4.
2. Loosen the two thumbscrews on the rear panel to release the rear cover from
the chassis.
Thumbscrews
A protection lm is pre-attached
to the system cover before
shipping. Please remove the
protection lm before turning
on the system for proper heat
dissipation.
Front side screw
2-3ASUS RS300-E8 Series
2.2 Central Processing Unit (CPU)
The motherboard comes with a surface mount LGA 1150 Socket designed for the
Intel® Sandy Bridge and Ivy Bridge series processors.
2.2.1 Installing the CPU
To install a CPU
1. Locate the CPU socket on the motherboard.
Ensure that all power cables are unplugged before installing the CPU.
• Upon purchase of the motherboard, ensure that the PnP cap is on
the socket and the socket contacts are not bent. Contact your retailer
immediately if the PnP cap is missing, or if you see any damage to the PnP
cap/socket contacts/motherboard components. ASUS shoulders the repair
cost only if the damage is shipment/transit-related.
• Keep the cap after installing the motherboard. ASUS will process Return
Merchandise Authorization (RMA) requests only if the motherboard comes
with the cap on the LGA 1150 socket.
• The product warranty does not cover damage to the socket contacts
resulting from incorrect CPU installation/removal, or misplacement/loss/
incorrect removal of the PnP cap.
Before installing the CPU, ensure that the socket box is facing toward you and
the load lever is on your right.
Chapter 2: Hardware setup2-4
Do not remove the PnP cap yet
from the CPU socket. Doing so
may bend the pins of the socket.
2. Press the load lever with your
thumb (A), then move it to the right
(B) until it is released from the
retention tab.
Retention tab
Load lever
3. Lift the load lever until the load plate
is completely lifted.
Load plate
4. Position the CPU above the socket,
ensuring that the gold triangle mark
is on the bottom-left corner of the
socket, then t the CPU notches to
the socket's alignment keys.
The CPU ts in only one orientation.
DO NOT force the CPU into the
socket to prevent bending the
pins on the socket and damaging
the CPU.
Gold
triangle
mark
CPU notches
Alignment
key
Alignment
key
2-5ASUS RS300-E8 Series
5. Close the load plate (A), ensuring
that the front edge of the load plate
slides under the retention lock (B)
then push down the load lever (C).
Retention
lock
Load lever
6. Insert the load lever under the retention tab to remove the PnP cap from the
CPU socket.
Retention
tab
Load
lever
7. Apply some Thermal Interface Material
to the exposed area of the CPU that
the heatsink will be in contact with,
ensuring that it is evenly spread in a
thin layer.
Some heatsinks come with pre-
applied Thermal Interface Material.
If so, skip this step.
The Thermal Interface Material is
toxic and inedible. DO NOT eat it.
If it gets into your eyes or touches
your skin, wash it off immediately
and seek professional medical
help.
Chapter 2: Hardware setup2-6
2.2.2 Installing the CPU heatsink and airduct
To install the CPU heatsink
• Tighten the four heatsink screws in a diagonal sequence.
• Do not remove the mylar on the heatsink.
AB
BA
3. Twist each of the four screws with
a Philips (cross) screwdriver just
enough to attach the heatsink to
the motherboard. When the four
screws are attached, tighten them
one by one to completely secure
the heatsink.
2. Place the heatsink on top of the
installed CPU, ensuring that the
four fasteners match the holes on
the motherboard.
1. Remove the protection sticker on
the back of the CPU heatsink.
2-7ASUS RS300-E8 Series
4. Secure the heat pipe and air duct
to the server with two screws.
5. Insert the two tips of the system
fan mylar into the CPU heatsink, as
shown in the right gure.
Chapter 2: Hardware setup2-8
2.3 System memory
2.3.1 Overview
The motherboard comes with six (6) Double Data Rate 3 (DDR3) Dual Inline
Memory Modules (DIMM) sockets.
The gure illustrates the location of the DDR3 DIMM sockets:
2.3.2 MemoryCongurations
You may install 2GB, 4GB and 8GB Unbuffered with ECC DDR3 DIMMs into the
DIMM sockets using the memory congurations in this section.
UDIMM
DIMM Slot Per
Channel
DIMM Populated
per Channel DIMM Type Speed Rank per DIMM
21Unbuffered DDR3 ECC 1333/1600 Single Rank,
Dual Rank
2 2 Unbuffered DDR3 ECC 1333/1600 Single Rank,
Dual Rank
• Always install DIMMs with the same CAS latency. For optimum compatibility,
it is recommended that you obtain memory modules from the same vendor.
• Start installing the DIMMs in slots A2 and B2 (Blue).
2-9ASUS RS300-E8 Series
2.3.3 Installing a DIMM
3. Hold the DIMM by both of its ends
then insert the DIMM vertically
into the socket. Apply force to both
ends of the DIMM simultaneously
until the retaining clip snaps back
into place and the DIMM cannot
be pushed in any further to ensure
proper sitting of the DIMM. Locked Retaining Clip
3
1. Unlock a DIMM socket by pressing
the retaining clip outward.
2. Align a DIMM on the socket
such that the notch on the DIMM
matches the DIMM slot key on the
socket.
Unlocked retaining clip
DIMM notch
2
1
DIMM slot key
1. Press the retaining clip outward to
unlock the DIMM.
2. Remove the DIMM from the socket.
1
2
Removing a DIMM from a single clip DIMM socket
• To install two or more DIMMs, refer to the user guide bundled in the
motherboard package.
• Refer to the user guide for qualied vendor lists of the memory modules.
Support the DIMM lightly with your ngers when pressing the retaining clips. The
DIMM might get damaged when it ips out with extra force.
Always insert the DIMM into the socket vertically to prevent DIMM notch
damage.
A DIMM is keyed with a notch so that it ts in only one direction. DO NOT force a
DIMM into a socket in the wrong direction to avoid damaging the DIMM.
Chapter 2: Hardware setup2-10
2.4 Hard disk drives
The system supports four hot-swap SATAIII/SAS hard disk drives and two SATAII
hard disk drives. The hard disk drive installed on the drive tray connects to the
motherboard SATA/SAS ports via the SATA/SAS backplane.
3. Take note of the drive tray holes.
Each side has three holes to t
different types of hard disk drives.
Use two screws on each side to
secure the hard disk drive.
2. Firmly hold the tray lever and pull
the drive tray out of the bay.
spring lock
To install a hot-swap SATA/SAS HDD
1. Release a drive tray by pushing the
spring lock to the right, then pulling
the tray lever outward. The drive
tray ejects slightly after you pull out
the lever.
2-11ASUS RS300-E8 Series
4. Place a SATA/SAS hard disk drive
on the tray, then secure it with four
screws.
5. Carefully insert the drive tray and
push it all the way to the depth of
the bay until just a small fraction of
the tray edge protrudes.
6. Push the tray lever until it clicks,
and secures the drive tray in place.
The drive tray is correctly placed
when its front edge aligns with the
bay edge.
7. Repeat steps 1 to 6 if you wish to
install a second SATA/SAS drive.
When installed, the SATA/SAS connector on the drive connects to the SATA/
SAS interface on the backplane.
Chapter 2: Hardware setup2-12
2.5 Expansion slot
2.5.1 Installing an expansion card to the riser card bracket
The barebone server comes with a riser card bracket. You need to remove the
bracket if you want to install PCI Express x8 or x16 expansion cards.
To install a PCI Express x8 or x16 card:
2. Place the riser card bracket on a
at and stable surface, then remove
the screw from the slot bay.
1. Firmly hold the riser card bracket,
then pull it up to detach it from
the PCI Express x16 slot on the
motherboard.
4. Repeat the previous steps to Install another PCI Express x8 or x16 card if
needed.
3. Install a PCI Express x8 or x16
card to the bracket as shown, then
secure the card with a screw.
2-13ASUS RS300-E8 Series
To reinstall the riser card bracket:
1. Align the riser card bracket with
the cards to the PCI Express x16
slot on the motherboard.
2. Press the riser card bracket until
the golden connectors completely
t the slot and the bracket aligns
with the rear panel.
3. Connect the cable(s) to the card,
if applicable.
Chapter 2: Hardware setup2-14
2.5.2 Conguringanexpansioncard
After installing the expansion card, congure the it by adjusting the software
settings.
1. Turn on the system and change the necessary BIOS settings, if any. See
Chapter 5 for information on BIOS setup.
2. Assign an IRQ to the card. Refer to the following tables.
3. Install the software drivers for the expansion card.
Standard Interrupt assignments
* These IRQs are usually available for ISA or PCI devices.
IRQ Priority Standard function
01 System Timer
12Keyboard Controller
2- Programmable Interrupt
3* 11 Communications Port (COM2)
4* 12 Communications Port (COM1)
5* 13 --
614 Floppy Disk Controller
7* 15 --
83System CMOS/Real Time Clock
9* 4 ACPI Mode when used
10* 5IRQ Holder for PCI Steering
11* 6IRQ Holder for PCI Steering
12* 7PS/2 Compatible Mouse Port
13 8 Numeric Data Processor
14* 9 Primary IDE Channel
15* 10 Secondary IDE Channel
2-15ASUS RS300-E8 Series
2.6 Cable connections
• The bundled system cables are pre-connected before shipment. You do
not need to disconnect these cables unless you will remove pre-installed
components to install additional devices.
• Refer to Chapter 4 for detailed information on the connectors.
Standard cables connected to the motherboard
1. 24-pin ATX power connector (from power supply to motherboard)
2. 8-pin 12V power connector (from power supply to motherboard)
3. System fan connector (from system fan to motherboard)
4. USB connector (from motherboard to front I/O board)
5. SATA conectors (system default; from motherboard to SATA/SAS backplane)
6. System auxiliary panel connector (from motherboard to front I/O board)
7. System panel connector (from motherboard to front I/O board)
8. SAS connectors (for ASUS PIKE only; from motherboard to SATA/SAS backplane)
9. PIKE Serial General Purpose Input/Output connectors
10. Serial General Purpose Input/Output connectors
1
2
76
8
3
9
5
4
3
3
3
10
Chapter 2: Hardware setup2-16
2.7 SATA/SAS backplane cabling
* For PIKE RAID solution, ensure to connect SAS_SGPIO_CON1 to support PIKE card SAS RAID
function.
Connect the SATAII/SAS HDDsConnects the data cables
connected to the motherboard
SGPIO_SELjumper:
pins 1-2 (Onboard)
pins 2-3 (Add-on card)
SAS_SGPIO_CON1
connector*
Connects a 8-pin
plug from power
supply
RS300-E8-PS4
RS300-E8-RS4
2-17ASUS RS300-E8 Series
2.8 Removable/optional components
You may need to remove previously installed system components when installing
or removing system devices. Or you may need to install the optional components
into the system. This section tells how to remove/install the following components:
1. System fans
2. ASUS PIKE RAID card (optional)
3. ASUS ASMB7-iKVM (optional)
4. SSD cage (optional)
Ensure that the system is turned off before removing any components.
2.8.1 System fans
To uninstall the system fans:
1. Disconnect the system fan cable
from the fan connector on the
motherboard.
2. Lift the fan, then set aside.
3. Repeat steps 1 to 2 to uninstall the
other system fans.
To reinstall the system fans
1. Insert the fan to the fan cage. The
airow directional arrow on the
fan side should point towards the
system rear panel.
2. Connect the system fan cable to the
fan connector on the motherboard.
Chapter 2: Hardware setup2-18
2.8.2 Installing ASUS PIKE RAID card (optional)
Follow the steps below to install an optional ASUS RAID card on your motherboard.
1. Locate the PIKE RAID card slot on
the motherboard.
2. Align the golden ngers of the
RAID card with the PIKE RAID card
slot.
3. Insert the RAID card into the PIKE
RAID card slot. Ensure that it is
completely seated on the PIKE
RAID card slot.
4. Remove the SATA/SAS cables from
the onboard SATA1–4 connectors.
2-19ASUS RS300-E8 Series
5. Connect the SATA/SAS cables to
the onboard SAS1–4 connectors
(blue).
6. Move the SGPIO_SEL1 jumper on
the SATA/SAS backplane to 2–3.
Chapter 2: Hardware setup2-20
2.8.3 Installing ASMB7 series management board (optional)
Follow the steps below to install an optional ASMB7 series management board on
your motherboard.
3. Insert the LAN cable plug to the
LAN port 5 (dedicated LAN) or
LAN port 1 (shared LAN) for server
management.
1. Locate the ASMB7 header on the
motherboard.
LAN port 5 LAN port 1
2. Orient and press the ASMB7
management card in place.
2-21ASUS RS300-E8 Series
2.8.4 Installing the SSD cage (optional)
Follow the steps below to install the optional SSD cage on your server module.
4. Connect the SATA power cable and
the SATA connector to the SSD card.
2. With the SSD cage resting on a at
surface, insert the SSD card into the
SSD cage.
3. Secure the SSD card into the SSD
cage with the bundled screws.
• The SS Card ts in one
orientation only.
• You can place two SSD cards
into the SSD cage.
SATA Power
cable
SATA
connector
1. Remove the three screws on the side
of the SSD cage.
2. Lift the SSD cage and set aside.
Chapter 2: Hardware setup2-22
5. Secure the SDD cage to the server
module using the bundled screws.
6. Connect the SATA cable connector.
to the onboard SATA connectors
7. Connect the Power cable to the
connector on the motherboard.
2-
This chapter describes how to install
the optional components and devices
into the barebone server.
Chapter 3
Installation options
Chapter 3: Installation options3-2
3.1 Friction Rail Kit Installation Guide
Your friction rail kit package contains:
• One pair of rack rails
• One pair of xing latches
• 4 latch screws, 4 rail screws and 4 rail washers (2 more for each buffer)
3.1.1 Attachingthexinglatchestotheserver
1. Secure the two xing latches to the two sides of the server with the four latch
screws.
Rack railsFixing latchesFront end Rear end
Latch screws Rail screws
Rail Washers
Fixing latch
The locations of the screw
holes vary with different server
models. Refer to your server
user manual for details.
3-3ASUS RS300-E8 Series
2. Select a 1U space on the rack
where you want to install the
rack rail. A 1U space consists
of three square mounting holes
with two thin lips on the top and
the bottom, as shown in the right
gure.
3. Adjust the rack rail to t the depth
of the rack.
5. Secure the front and rear ends of the
rail with two rack screws and washers.
6. Repeat step 3 to 5 to attach the rack rail
on the other side of the rack.
4. From inside the rack, place the rear
rail hook on the bottom thin lip of the
rear mounting hole, and then place the
front rail hook on the bottom thin lip of
the front mounting hole, as shown in
the right gure.
Chapter 3: Installation options3-4
Do not install the rail kit in the following situation:
DO NOT place the rail hook on a thick lip of
the mounting hole.
DO NOT install the rail to the outer side of
the server rack.
7. When mounting the server to the rack,
ensure to include the side knots on the
two sides of the server in the rack rail
holders, as shown in the right gure.
This chapter includes the motherboard
layout and brief descriptions of the
jumpers and internal connectors.
Chapter 4
Motherboard Info
Chapter 4: Motherboard information4-2
4.1 Motherboard layout
Layout contents
Jumpers Page
1. Clear RTC RAM (CLRTC1) 4-4
2. VGA controller setting (3-pin VGA_SW1) 4-5
3. LAN controller setting
(3-pin LAN_SW1, LAN_SW2, LAN_SW3, LAN_SW4) 4-5
4. RAID conguration utility selection (3-pin RAID_SEL1) 4-6
5. Platform Environmental Control Interface (PECI) Setting
(3-pin PECI1) 4-6
ASUS RS300-E8 Series 4-3
Internal connectors Page
1. Serial ATA 6.0/3.0 Gbps connector
(7-pin 6Gbps SATA1, SATA2, SATA3, SATA4 [Light Blue])
(7-pin 3Gbps SATA5, SATA6 [Black])
4-7
2. PSAS connectors
(7-pin PSAS1, PSAS2, PSAS3, PSAS4, PSAS5, PSAS6, PSAS7,
PSAS8 [Blue])
4-8
3. Hard disk activity LED connector (4-pin HDLED1) 4-9
5. USB 2.0 connector (10-1 pin USB78; A-Type USB9) 4-9
6. USB 3.0 connector (20-1 pin USB3_34) 4-10
7. Thermal sensor cable connectors (3-pin TR1) 4-10
8. CPU, front, and rear fan connectors
(4-pin CPU_FAN1, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3,
REAR_FAN1)
4-11
9. Serial General Purpose Input/Output connector (6-1 pin
SGPIO1)
PIKE Serial General Purpose Input/Output connectors
(8-1 pin PSGPIO1, PSGPIO2)
4-12
9. Serial port connectors (10-1 pin COM1/COM2) 4-13
10. Power Supply SMBus connector (5-pin PSUSMB1) 4-13
11. Trusted Platform Module connector (20-1 pin TPM1) 4-14
12. SATA DOM power connector (4-pin PWR3) 4-14
13. LAN34_LED connector (5-pin LAN34_LED1) 4-15
14. Parallel port connector (26-1 pin LPT1) 4-15
15. VGA connector (16-1 pin VGA_HDR1) 4-16
16. ATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1) 4-17
17. System panel connector (20-1 pin PANEL1) 4-18
18. Auxiliary panel connector (20-2 pin AUX_PANEL1) 4-19
Onboard LEDs Page
1. Standby Power LED (SB_PWR1) 4-20
2. Baseboard Management Controller LED (BMC_LED1) 4-20
3. CPU Warning LED (ERR_CPU1) 4-21
4. Power LED (+5V_LED1) 4-21
5. Location LED (LOCLED1) 4-22
Chapter 4: Motherboard information4-4
4.2 Jumpers
1. Clear RTC RAM (3-pin CLRTC1)
This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS.
You can clear the CMOS memory of date, time, and system setup parameters
by erasing the CMOS RTC RAM data. The onboard button cell battery
powers the RAM data in CMOS, which include system setup information such
as system passwords.
To erase the RTC RAM:
1. Turn OFF the computer and unplug the power cord.
2. Move the jumper cap from pins 1–2 (default) to pins 2–3. Keep the cap on
pins
2–3 for about 5–10 seconds, then move the cap back to pins 1–2.
3. Plug the power cord and turn ON the computer.
4. Hold down the <Del> key during the boot process and enter BIOS setup
to re-enter data.
Except when clearing the RTC RAM, never remove the cap on CLRTC jumper
default position. Removing the cap will cause system boot failure!
If the steps above do not help, remove the onboard battery and move the jumper
again to clear the CMOS RTC RAM data. After the CMOS clearance, reinstall
the battery.
ASUS RS300-E8 Series 4-5
2. VGA controller setting (3-pin VGA_SW1)
This jumper allows you to enable or disable the onboard VGA controller. Set
to pins 1–2 to activate the VGA feature.
3. LAN controller setting (3-pin LAN_SW1, LAN_SW2, LAN_SW3,
LAN_SW4)
These jumpers allow you to enable or disable the onboard Intel® I210AT Gigabit
LAN controllers. Set to pins 1-2 to activate the Gigabit LAN feature.
Chapter 4: Motherboard information4-6
4. RAIDcongurationutilityselection(3-pinRAID_SEL1)
This jumper allows you to select the RAID conguration utility to use when
you create disk arrays. Place the jumper caps over pins 2–3 to use the Intel®
Rapid Storage Technology.
5. Platform Enviromental Control Interface Setting (3-pin PECI1)
When an ASMB7-iKVM is installed, set these to pins 2-3 for correct sensor
information of the Platform Environmental Control Interface (PECI). Set to
pins 1-2 if ASMB7-iKVM is not installed.
P9D-C/4L
®
P9D-C Series RAID setting
RAID_SEL1
3 Party
(Default)
Intel
12 2 3
ASUS RS300-E8 Series 4-7
4.3 Internal connectors
1. Serial ATA 6.0/3.0 Gbps connectors
(7-pin 6Gbps SATA1, SATA2, SATA3, SATA4 [Light Blue])
(7-pin 3Gbps SATA5, SATA6 [Black])
Supported by the Intel® C224 chipset, these connectors are for the Serial ATA
signal cables for Serial ATA hard disk drives that allows up to 6Gbps of data
transfer rate.
If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1,
RAID 10, or RAID 5 conguration.
The actual data transfer rate depends on the speed of Serial ATA hard disks
installed.
Chapter 4: Motherboard information4-8
2. PSAS connectors
(7-pin PSAS1, PSAS2, PSAS3, PSAS4, PSAS5, PSAS6, PSAS7, PSAS8
[Light Blue])
This motherboard comes with eight (8) PIKE Serial Attached SCSI (PSAS)
connectors that supports both Serial Attached SCSI (SAS) and Serial ATA
(SATA). Each connector supports one device.
• These connectors function only when you install a PIKE RAID card.
• Connect the SAS hard disk drives to PSAS connectors 1–8 (blue) when
installing a PIKE RAID card.
ASUS RS300-E8 Series 4-9
3. Hard disk activity LED connector (4-pin HDLED1)
This LED connector is for the storage add-on card cable connected to
the SATA or SAS add-on card. The read or write activities of any device
connected to the SATA or SAS add-on card causes the front panel LED to
light up.
4. USB 2.0 connector (10-1 pin USB78; A-Type USB9)
These connectors are for USB 2.0 ports. Connect the USB module cables to
these connectors. These USB connectors comply with USB 2.0 specication
that supports up to 480 Mbps connection speed.
Chapter 4: Motherboard information4-10
5. USB 3.0 connector (20-1 pin USB3_34)
These connectors allow you to connect a USB 3.0 module for additional
USB 3.0 front or rear panel ports. With an installed USB 3.0 module, you can
enjoy all the benets of USB 3.0 including faster data transfer speeds of up
to 5Gbps, faster charging time for USB-chargeable devices, optimized power
efciency, and backward compatibility with USB 2.0.
6. Thermal sensor cable connectors (3-pin TR1)
This connector allows you to connect a Thermal sensor cable that is used for
monitoring temperature. Connect the Thermal sensor cable to the connector
and place its probe to the device that you want to monitor.
ASUS RS300-E8 Series 4-11
7. CPU, front, and rear fan connectors
(4-pin CPU_FAN1, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3, REAR_FAN1)
The fan connectors support cooling fans. Connect the fan cables to the fan
connectors on the motherboard, ensuring that the black wire of each cable
matches the ground pin of the connector.
• DO NOT forget to connect the fan cables to the fan connectors. Insufcient
air ow inside the system may damage the motherboard components.
• These are not jumpers! DO NOT place jumper caps on the fan connectors!
• All connectors feature the ASUS Smart Fan technology.
Chapter 4: Motherboard information4-12
8. Serial General Purpose Input/Output connector (6-1 pin SGPIO1)
The SGPIO 1 connectors are used for the Intel Rapid Storage Technology
Enterprise SGPIO interface that controls the LED pattern generation, device
information, and general purpose data.
The PSGPIO 1 and PSGPIO 2 connectors only functions when you install
an ASUS PIKE RAID card.
ASUS RS300-E8 Series 4-13
9. Serial port connectors (10-1 pin COM1/COM2)
These connectors are for the serial COM ports. Connect the serial port
module cable to one of these connectors, then install the module to a slot
opening at the back of the system chassis.
10. Power Supply SMBus connector (5-pin PSUSMB1)
This connector allows you to connect SMBus (System Management Bus) to
the power supply unit to read PSU information. Devices communicate with an
SMBus host and/or other SMBus devices using the SMBus interface.
This connector functions only when you install the ASUS ASMB7.
Chapter 4: Motherboard information4-14
11. Trusted Platform Module connector (20-1 pin TPM1)
This connector supports a Trusted Platform Module (TPM) system, which can
securely store keys, digital certicates, passwords, and data. A TPM system
also helps enhance network security, protects digital identities, and ensures
platform integrity.
12. SATA DOM power connector (4-pin PWR3)
This 4-pin connector is for 5V power of a certain SATA DOM (Disk on Module)
device when using an appropriate cable.
• The SATA DOM power connector is for output power only. It has a maximum
output current of 1A.
• Ensure that the power of the SATA DOM device that you will use is less than
1A.
ASUS RS300-E8 Series 4-15
13. LAN34_LED connector (5-1 pin LAN34_LED1)
These leads are for Gigabit LAN activity LEDs on the front panel. Connect the
LAN LED cable to the backplane for LAN activity indication.
14. Parallel port connector (26-1 pin LPT1)
This connector is for the parallel port. Connect the parallel port module cable
to this connector, then install the module to a slot opening at the back of the
system chassis.
Chapter 4: Motherboard information4-16
15. VGA connector (16-1 pin VGA_HDR1)
This connector supports the VGA High Dynamic-Range interface.
ASUS RS300-E8 Series 4-17
16. ATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1)
These connectors are for the ATX power supply plugs. The power supply plugs
are designed to t these connectors in only one orientation. Find the proper
orientation and push down rmly until the connectors completely t.
• DO NOT forget to connect the 24-pin and the 8-pin power plugs otherwise
the system will not boot up.
• Use of a power supply unit (PSU) with a higher power output is recommended
when conguring a system with more power-consuming devices. The system
may become unstable or may not boot up if the power is inadequate.
• This motherboard supports ATX2.0 PSU or later version.
• Ensure that your PSU can provide at least the minimum power required by
your system.
Chapter 4: Motherboard information4-18
17. System panel connector (20-1 pin PANEL1)
This connector supports several chassis-mounted functions.
1. System power LED (3-pin PLED)
This 3-pin connector is for the system power LED. Connect the chassis
power LED cable to this connector. The system power LED lights up
when you turn on the system power, and blinks when the system is in
sleep mode.
2. Message LED (2-pin MLED)
This 2-pin connector is for the message LED cable that connects to the
front message LED. The message LED is controlled by Hardware monitor
to indicate an abnormal event occurance.
3. System warning speaker (4-pin SPEAKER)
This 4-pin connector is for the chassis-mounted system warning speaker.
The speaker allows you to hear system beeps and warnings.
4. Hard disk drive activity LED (2-pin +HDLED)
This 2-pin connector is for the HDD Activity LED. Connect the HDD Activity
LED cable to this connector. The IDE LED lights up or ashes when data
is read from or written to the HDD.
5. Power button/soft-off button (2-pin PWRSW)
This connector is for the system power button. Pressing the power button
turns the system on or puts the system in sleep or soft-off mode depending
on the BIOS settings. Pressing the power switch for more than four seconds
while the system is ON turns the system OFF.
ASUS RS300-E8 Series 4-19
18. Auxiliary panel connector (20-2 pin AUX_PANEL1)
This connector is for additional front panel features including front panel SMB,
Locator LED and switch, chassis intrusion, and LAN LEDs.
1. Front panel SMB (6-1 pin FPSMB)
These leads connect the front panel SMBus cable.
2. LAN activity LED (2-pin LAN1LINK and 2-pin LAN2LINK)
These leads are for Gigabit LAN activity LEDs on the front panel.
3. Chassis intrusion (4-1 pin AUX_CHASSIS)
These leads are for the intrusion detection feature for chassis with intrusion
sensor or microswitch. When you remove any chassis component, the
sensor triggers and sends a high-level signal to these leads to record a
chassis intrusion event. The default setting is short CASEOPEN and GND
pin by jumper cap to disable the function.
4. Locator LED (2-pin AUX_LOCLED1 and 2-pin AUX_LOCLED2)
These leads are for the Locator LED1 and LED2 on the front panel. Connect
the Locator LED cables to these 2-pin connector. The LEDs will light up
when the Locator button is pressed.
5. Locator Button/Switch (2-pin AUX_BMCLOCBNT)
These leads are for the locator button on the front panel. This button queries
the state of the system locator.
6. Reset button (2-pin RESET)
This 2-pin connector is for the chassis-mounted reset button for system
reboot without turning off the system power.
Chapter 4: Motherboard information4-20
2. Baseboard Management Controller LED (BMC_LED1)
The green heartbeat LED blinks per second to indicate that the ASMB7 is
working normally. The BMC LED works with the ASUS ASMB7 management
device and indicates its initiation status. When the PSU is plugged and the
system is OFF, ASUS ASMB7 management device starts system initiation for
about one (1) minute. The BMC LED blinks after system initiation nishes.
4.4 Internal LEDs
1. Standby Power LED (SB_PWR1)
The motherboard comes with a standby power LED. The green LED lights up
to indicate that the system is ON, in sleep mode, or in soft-off mode. This is a
reminder that you should shut down the system and unplug the power cable
before removing or plugging in any motherboard component. The illustration
below shows the location of the onboard LED.
ASUS RS300-E8 Series 4-21
3. CPU Warning LED (ERR_CPU1)
The CPU warning LED lights up to indicate that a CPU error or failure has
occurred.
4. Power LED (+5V_LED1)
This LED lights up when the Power-on button is pressed and the system is
on.
• The heartbeat LED functions only when you install the ASUS ASMB7
Management card.
• Everytime after the AC power is replugged, you have to wait for about 60
seconds for the system to power up.
The warning LED functions only when you install the ASUS ASMB7
Management card.
Chapter 4: Motherboard information4-22
5. Location LED (LOCLED1)
The Location LED is an onboard LED that ligths up when the Location Button on
the front panel is pressed. This LED helps you visually locate the server among
other servers especially when you are located at the back of the server rack.
This chapter tells how to change the
system settings through the BIOS
Setup menus. Detailed descriptions
of the BIOS parameters are also
provided.
Chapter 5
BIOS setup
5-2 Chapter 5: BIOS setup
5.1.1 ASUS CrashFree BIOS 3 utility
The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore
the BIOS le when it fails or gets corrupted during the updating process. You can
update a corrupted BIOS le using a USB ash drive that contains the updated
BIOS le.
Prepare a USB ash drive containing the updated motherboard BIOS before using this
utility.
RecoveringtheBIOSfromaUSBashdrive
To recover the BIOS from a USB ash drive:
1. Insert the USB ash drive with the original or updated BIOS le to one USB port
on the system.
2. The utility will automatically recover the BIOS. It resets the system when the
BIOS recovery nished.
DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause
system boot failure!
The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the ASUS
website at www.asus.com to download the latest BIOS le.
Save a copy of the original motherboard BIOS le to a bootable USB ash disk drive in case
you need to restore the BIOS in the future. Copy the original motherboard BIOS using the
BUPDATER utility.
5.1 Managing and updating your BIOS
The following utilities allow you to manage and update the motherboard Basic Input/
Output System (BIOS) setup:
1. ASUS CrashFree BIOS 3
To recover the BIOS using a bootable USB ash disk drive when the BIOS le
fails or gets corrupted.
2. ASUS EzFlash
Updates the BIOS using a USB ash disk.
3. BUPDATER
Updates the BIOS in DOS mode using a bootable USB ash disk drive.
Refer to the corresponding sections for details on these utilities.
ASUS RS300-E8 Series 5-3
3. Press <Tab> to switch to the Drive eld.
4. Press the Up/Down arrow keys to nd the USB ash disk that contains the latest
BIOS then press <Enter>.
5. Press <Tab> to switch to the Folder Info eld.
6. Press the Up/Down arrow keys to nd the BIOS le then press <Enter>.
7. Reboot the system when the update process is done.
5.1.2 ASUS EzFlash Utility
The ASUS EzFlash Utility feature allows you to update the BIOS without having to
use a DOS-based utility.
Before you start using this utility, download the latest BIOS from the ASUS website at www.
asus.com.
To update the BIOS using EzFlash Utility:
1. Insert the USB ash disk that contains the latest BIOS le to the USB port.
2. Enter the BIOS setup program. Go to the Tool menu to select ASUS EzFlash
Utility and press <Enter> to enable it.
ASUS Tek. Easy Flash Utility
[Up/Down/Left/Right]:Switch [Enter]:Choose [q]:Exit
FS0 System Volume Information <DIR>
P9D-E-4L Bios <DIR>
Windows <DIR>
P9D-C/4L Bios <DIR>
Current Platform
Platform : P9D-C/4L
Version : 0051
Build Date :11/26/2012
New Platform
Platform : P9D-C/4L
Version : 0060
Build Date :12/03/2012
The succeeding BIOS screens are for reference only. The actual BIOS screen displays may
not be the same as shown.
5-4 Chapter 5: BIOS setup
5.1.3 BUPDATER utility
The succeeding BIOS screens are for reference only. The actual BIOS screen displays may
not be the same as shown.
The BUPDATER utility allows you to update the BIOS le in DOS environment
using a bootable USB ash disk drive with the updated BIOS le.
UpdatingtheBIOSle
To update the BIOS le using the BUPDATER utility:
1. Visit the ASUS website at www.asus.com and download the latest BIOS le
for the motherboard. Save the BIOS le to a bootable USB ash disk drive.
2. Download the BUPDATER utility (BUPDATER.exe) from the ASUS support
website at support.asus.com to the bootable USB ash disk drive you created
earlier.
3. Boot the system in DOS mode, then at the prompt, type:
BUPDATER/i[lename].CAP
where [lename] is the latest or the original BIOS le on the bootable USB
ash disk drive, then press <Enter>.
A:\>BUPDATER /i[le name]CAP
7. Reboot the system when the update process is done.
• This function can support devices such as a USB ash disk with FAT 32/16 format and
single partition only.
• DO NOT shut down or reset the system while updating the BIOS to prevent system boot
failure!
Ensure to load the BIOS default settings to ensure system compatibility and stability. Press
<F5> and select Yes to load the BIOS default settings.
ASUS RS300-E8 Series 5-5
The utility veries the le, then starts updating the BIOS le.
DO NOT shut down or reset the system while updating the BIOS to prevent system boot
failure!
The utility returns to the DOS prompt after the BIOS update process is
completed.
4. Reboot the system from the hard disk drive.
The BIOS update is nished! Please restart your system.
C:\>
ASUSTek BIOS Update for DOS V1.06 (09/08/04)
Current ROM Update ROM
Note
Writing BIOS:
FLASH TYPE: MXIC 25L1605A
PATH:
BOARD: P9D-C/4L
VER: 0201
DATE: 12/01/2013
BOARD: P9D-C/4L
VER: 0202
DATE: 12/09/2013
WARNING! Do not turn off power during ash BIOS
5-6 Chapter 5: BIOS setup
5.2 BIOS setup program
This motherboard supports a programmable rmware chip that you can update
using the provided utility described in section 5.1 Managing and updating your
BIOS.
Use the BIOS Setup program when you are installing a motherboard, reconguring
your system, or prompted to “Run Setup.” This section explains how to congure
your system using this utility.
Even if you are not prompted to use the Setup program, you can change the
conguration of your computer in the future. For example, you can enable the
security password feature or change the power management settings. This
requires you to recongure your system using the BIOS Setup program so that the
computer can recognize these changes and record them in the CMOS RAM of the
rmware chip.
The rmware chip on the motherboard stores the Setup utility. When you start up
the computer, the system provides you with the opportunity to run this program.
Press <Del> during the Power-On Self-Test (POST) to enter the Setup utility;
otherwise, POST continues with its test routines.
If you wish to enter Setup after POST, restart the system by pressing
<Ctrl>+<Alt>+<Delete>, or by pressing the reset button on the system chassis. You
can also restart by turning the system off and then back on. Do this last option only
if the rst two failed.
The Setup program is designed to make it as easy to use as possible. Being a
menu-driven program, it lets you scroll through the various sub-menus and make
your selections from the available options using the navigation keys.
• The default BIOS settings for this motherboard apply for most conditions to ensure
optimum performance. If the system becomes unstable after changing any BIOS
settings, load the default settings to ensure system compatibility and stability. Press
<F5> and select Yes to load the BIOS default settings.
• The BIOS setup screens shown in this section are for reference purposes only, and
may not exactly match what you see on your screen.
• Visit the ASUS website (www.asus.com) to download the latest BIOS le for this
motherboard.
ASUS RS300-E8 Series 5-7
5.2.2 Menu bar
The menu bar on top of the screen has the following main items:
Main For changing the basic system conguration
Advanced For changing the advanced system settings
Event Logs For changing the event log settings
Boot For changing the system boot conguration
Monitor For displaying the system temperature, power status, and
changing the fan settings
Security For changing the security settings
Tool For conguring options for special functions
Exit For selecting the exit options
To select an item on the menu bar, press the right or left arrow key on the keyboard
until the desired item is highlighted.
5.2.1 BIOS menu screen
Version 2.15.1236. Copyright (C) 2013 American Megatrends, Inc.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Set the Date, Use Tab to
switch between Data
elements.
→←: Select Screen
↑↓: Select Item
Enter: Select Item
+/-: Change Opt.
F1: General Help
F2: Previous Values
F5: Optimized Defaults
F10: Save & Exit
ESC: Exit
BIOS Information
BIOS Vendor American Megatrends
BIOS Version 4.6.5.4
Compliancy UEFI 2.3.1; PI 1.2
BIOS Version 0077 x64
Build Date 01/31/2013
System Date [Mon 02/21/2013]
System Time [10:10:10]
Navigation keys
General help
Menu bar CongurationeldsMenu items
5-8 Chapter 5: BIOS setup
5.2.3 Menu items
The highlighted item on the menu bar displays the specic items for that menu. For
example, selecting Main shows the Main menu items. The other items (Advanced,
Event Logs, Boot, Monitor, Security, Tool, and Exit) on the menu bar have their
respective menu items.
5.2.4 Submenu items
A solid triangle before each item on any menu screen means that the item has a
submenu. To display the submenu, select the item and press <Enter>.
PCI, PCI-X and PCI Express
Settings.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
PCI, PCI-X and PCI Express
Settings.
PCI Subsystem Settings
ACPI Settings
Trusted Computing
5.2.5 Navigation keys
At the bottom right corner of a menu screen are the navigation keys for the BIOS
setup program. Use the navigation keys to select items in the menu and change
the settings.
5.2.6 General help
At the top right corner of the menu screen is a brief description of the selected item.
5.2.7 Congurationelds
These elds show the values for the menu items. If an item is user-congurable,
you can change the value of the eld opposite the item. You cannot select an
item that is not user-congurable. A congurable eld is enclosed in brackets, and
is highlighted when selected. To change the value of a eld, select it and press
<Enter> to display a list of options.
5.2.8 Pop-up window
Select a menu item and press <Enter> to display a pop-up window with the
conguration options for that item.
5.2.9 Scroll bar
A scroll bar appears on the right side of a menu screen when there are items that
do not t on the screen. Press the Up/Down arrow keys or <Page Up> /<Page
Down> keys to display the other items on the screen.
ASUS RS300-E8 Series 5-9
5.3 Main menu
When you enter the BIOS Setup program, the Main menu screen appears. The
Main menu provides you an overview of the basic system information, and allows
you to set the system date and time.
5.3.1 System Date
Allows you to set the system date to [Day mm/dd/yyyy].
Where:
Day = Day of the week
mm = month (numeric value)
dd = day (numeric value)
yyyy = year (numeric value)
5.3.2 System Time
Allows you to set the system time to [hh/mm/ss].
Where:
hh = hour (numeric value)
mm = minutes (numeric value)
ss = seconds (numeric value)
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Set the Date, Use Tab to
switch between Data
elements.
BIOS InformationBIOS Vendor American Megatrends
BIOS Version 4.6.5.4
Compliancy UEFI 2.3.1; PI 1.2
BIOS Version 0077 x64
Build Date 01/31/2013
System Date [Mon 02/22/2013]
System Time [10:10:10]
5-10 Chapter 5: BIOS setup
5.4 Advanced menu
The Advanced menu items allow you to change the settings for the CPU and other
system devices.
Take caution when changing the settings of the Advanced menu items. Incorrect eld values
can cause the system to malfunction.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
PCI, PCI-X and PCI Express
Settings.
PCI Subsystem Settings
ACPI Settings
Trusted Computing
WHEA Conguration
CPU Conguration
PCH-IO Conguration
SATA Conguration
Systems Agent (SA) Conguration
USB Conguration
NCT6779D Super IO Conguration
Intel Server Platforms Services
Onboard LAN Conguration
MIO Card Conguration
Serial Port Console Redirection
APM
Network Stack
Intel RC Drivers Version Details
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
PCI, PCI-X and PCI
Express Settings.
CPU Conguration
PCH-IO Conguration
SATA Conguration
Systems Agent (SA) Conguration
PCI Subsystem Settings
USB Conguration
TPM
ACPI Settings
WHEA Conguration
NCT6779D Super IO Conguration
Intel Server Platform Services
Onboard LAN Conguration
MIO Card Conguration
Serial Port Console Redirection
Runtime Error Logging
APM
Network Stack
Intel RC Drivers Version Detail
ASUS RS300-E8 Series 5-11
5.4.1 CPUConguration
The items in this menu show the CPU-related information that the BIOS
automatically detects. Some items may not appear if your CPU does not support
the related functions.
To quickly go to the last item of the second page, press the Page Down button. Press the
Page Up button to go back to the rst item in the rst page.
Enabled for Windows XP and
Linux (OS optimized for
Hyper-Threading Technology)
and Disabled for other OS
(OS not optimized for Hyper-
Threading Technology).
When Disabled only one thread
per enabled core is enabled.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Version 2.15.1236. Copyright (C) 2013 American Megatrends, Inc.
Hyper-threading [Enabled]
Active Processor Cores [All]
Execute Disable Bit [Enabled]
Inter Virtualization Technology[Enabled]
Hardware Prefetcher [Enabled]
Adjacent Cache Line Prefetch [Enabled]
CPU AES [Enabled]
Boot performance mode [Turbo Performance]
EIST [Enabled]
Turbo Mode [Enabled]
Energy Performance [Performance]
CPU C states [Enabled]
Enhanced C1 state [Enabled]
CPU C3 Report [Enabled]
CPU C6 report [Enabled]
CPU C7 report [CPU C7s]
C1 state auto demotion [Enabled]
C3 state auto demotion [Enabled]
Package C State limit [AUTO]
LakeTiny Feature [Disabled]
Intel TXT (LT) Support [Disabled]
ACPI T State [Disabled]
→←: Select Screen
↑↓: Select Item
Enter: Select Item
+/-: Change Opt.
F1: General Help
F2: Previous Values
F5: Optimized Defaults
F10: Save & Exit
ESC: Exit
L2 Cache 25 6 kB x 4
L3 Cache 8192 kB
Navigate to the second page of the screen to see the rest of items in this menu by
pressing the Up or Down arrow keys.
Enabled for Windows XP and
Linux (OS optimized for
Hyper-Threading Technology)
and Disabled for other OS
(OS not optimized for Hyper-
Threading Technology).
When Disabled only one thread
per enabled core is enabled.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
CPU Conguration
Genuine Intel (R) CPU 0000 @ 2.50GHz
CPU Signature 306c2
Microcode Patch ffff0006
Max CPU Speed 2500 MHz
Min CPU Speed 800 MHz
CPU Speed 2500 MHz
Processor Cores 4
Intel HT Technology Supported
Intel VT-x Technology Supported
Intel SMX Technology Supported
64-bit Supported
EIST Technology Supported
CPU C3 State Supported
CPU C6 State Supported
CPU C7 State Supported
L1 Data Cache 32 kB x 4
L1 Code Cache 32 kB x 4
L2 Cache 256 kB x 4
L3 Cache 8192 kB
Version 2.15.1236. Copyright (C) 2013 American Megatrends, Inc.
→←: Select Screen
↑↓: Select Item
Enter: Select Item
+/-: Change Opt.
Enabled for WIndows XP
and Linux (OS optimized
for Hyper-Threading
Technology) and Disabled
for other OS (OS not
optimized for Hyper-
Threading Technology).
When Disabled only one
thread per enabled core is
enabled.
5-12 Chapter 5: BIOS setup
Hyper-threading [Enabled]
Allows you to enable or disable the Intel Hyper-Threading Technology function.
Conguration options: [Enabled] [Disabled]
Active Processor Cores [All]
Allows you to choose the number of CPU cores to activate in each processor package.
Conguration options: [All] [1] [2] [3]
Execute Disable Bit [Enabled]
Allows you to enable or disable the XD feature that can prevent certain classes of malicious
buffer overow attacks when combined with a supporting OS. Conguration options:
[Enabled][Disabled]
Intel Virtualization Technology [Enabled]
Allows you to utilize the additional hardware capabilities provided by Vanderpool Technology.
Conguration options: [Enabled] [Disabled]
Hardware Prefetcher [Enabled]
Allows you to enable or disable the Mid Level Cache (L2) streamer. Conguration options:
[Enabled] [Disabled]
AdjacentCacheLinePrefetch[Enabled]
Allows you to enable or disable the Mid Level Cache (L2) prefetching of adjacent cache lines.
Conguration options: [Enabled] [Disabled]
CPU AES [Enabled]
Allows you to enable or disable the CPU Advance Encryption Standard instructions.
Conguration options: [Disabled] [Enabled]
Boot performance mode [Turbo Performance]
This item allows you to select the performance state that the BIOS will set before OS handoff.
Conguration options: [Max Non-Turbo Performace] [Max Battery] [Turbo Performance]
EIST [Enabled]
Allows you to enable or disable the Enhanced Intel SpeedStep Technology (EIST).
Conguration options: [Enabled] [Disabled]
Turbo Mode [Enabled]
This item appears only when you set the EIST item to [Enabled]. This allows you to enable or
disable the Intel® Turbo Mode Technology.
Conguration options: [Enabled] [Disabled]
Energy Performance [Performance]
Allows you to optimize between performance and power savings. Conguration options:
[Performance] [Balanced Performance] [Balanced Energy] [Energy Efcient]
ASUS RS300-E8 Series 5-13
Enhanced C1 State [Enabled]
This item allows you to enable or disable the Enhanced C1 state. Configuration options:
[Enabled] [Disabled]
CPU C3 Report [Enabled]
Allows you to enable or disable the CPU C3 report to OS. Configuration options: [Enabled]
[Disabled]
CPU C6 Report [Enabled]
Allows you to enable or disable the CPU C6 report to OS. Configuration options: [Disabled]
[Enabled]
CPU C7 Report [CPU C7s]
Allows you to enable or disable the CPU C7 report to OS. Configuration options: [Disabled]
[CPU C7] [CPU C7s]
C1 state auto demotion [Enabled]
Allows you to enable or disable the demotion of the C3/C6/C7 request to C1 based on
uncore auto-demote information. Configuration options: [Disabled] [Enabled]
C3 state auto demotion [Enabled]
Allows you to enable or disable the demotion of the C6/C7 request to C3 based on uncore
auto-demote information. Configuration options: [Disabled] [Enabled]
Package C State limit [AUTO]
Allows you set the Package C State limit to AUTO. Conguration options: [C0/C1] [C2] [C3]
C6] [C7] [C7s] [AUTO]
LakeTiny Feature [Disabled]
Allows you enable or disable LakeTiny for C state conguration. Conguration options: [Disabled]
[Enabled]
Intel TXT (LT) Suppot [Disabled]
Allows you to enable or disable the Intel TXT (LT) support. Conguration options: [Disabled]
[Enabled]
ACPI T State [Disabled]
Allows you to enable or disable the ACPI T state. Conguration options: [Disabled] [Enabled]
This following items appears only when you set the CPU C states to [Enabled].
CPU C states [Enabled]
Allows you to enable or disable the CPU C states. Conguration options: [Enabled]
[Disabled]
5-14 Chapter 5: BIOS setup
5.4.2 PCH-IOConguration
Allows you to congure PCH parameters.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Intel PCH RC Version 1.0.0.0
Intel PCH SKU Name C224
Intel PCH Rev ID 04/C1
USB Conguration
PCH Azalia Conguration
USB Conguration
settings.
USBConguration
Allows you to set the USB Conguration settings.
USB Conguration settings
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Mode of operation of xHCI
controller.
USB Conguration
XHCI Mode [Auto]
EHCI1 [Enabled]
EHCI2 [Enabled]
USB Ports Per-Port Disable Control [Disabled]
XHCI Mode [Auto]
Allows you to set the mode of operation of the xHCI controller. Conguration options: [Auto]
[Enabled] [Disabled]
EHCI1 / EHCI2 [Enabled]
Allows you to control the USB EHCI (USB 2.0) functions. One EHCI controller must always
be enabled. Conguration options: [Disabled] [Enabled]
USB Ports Per-Port Disable Control [Disabled]
Allows you to control the disabling of the USB ports (0-13). Conguration options:
[Disabled] [Enabled]
USB Port #0-#13 Disable [Enabled]
This items only appears when you set the USB Ports Per-Port Disable Control to [Enabled]
This item allows you to control the disabling of each of the USB ports (0-13). Conguration
options: [Disabled] [Enabled]
ASUS RS300-E8 Series 5-15
5.4.3 SATAConguration
While entering Setup, the BIOS automatically detects the presence of SATA
devices. The SATA Port items show Not Present if no SATA device is installed to
the corresponding SATA port.
SATA Controller(s) [Enabled]
This allows you to enable or disable the SATA Device. Conguration options: [Enabled]
[Disabled]
SATA Mode Selection [AHCI]
This allows you to choose how SATA controller(s) should operate. Conguration options:
[AHCI] [IDE] [RAID]
S.M.A.R.T. Status Check [Enabled]
Self-Monitoring, Analysis, and Reporting Technology (S.M.A.R.T.) is a monitor system. When
read/write of your hard disk errors occur, this feature allows the hard disk to report warning
messages during the POST. Conguration options: [Enabled] [Disabled]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
SATA Controller(s) [Enabled]
SATA Mode Selection [AHCI]
S.M.A.R.T. Status Check [Enabled]
Serial ATA Port 0 HardDisk (250.0GB)
Software Preserve SUPPORTED
Port 0 [Enabled]
Hot Plug [Enabled]
SATA Device Type [Hard Disk Drive]
Spin Up Device [Disabled]
Serial ATA Port 1 HardDisk (250.0GB)
Software Preserve SUPPORTED
Port 1 [Enabled]
Hot Plug [Enabled]
SATA Device Type [Hard Disk Driver]
Spin Up Device [Disabled]
Serial ATA Port 2 HardDisk (250.0GB)
Software Preserve SUPPORTED
Port 2 [Enabled]
Hot Plug [Enabled]
SATA Device Type [Hard Disk Driver]
Spin Up Device [Disabled]
Enable or disable SATA
Device.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Control Detection of
the Azalia device.
Disabled = Azalia will be
unconditionally disabled
Enabled = Azalia will be
unconditionally Enabled
Auto = Azalia will be
enabled if present, disabled
otherwise.
PCH Azalia Conguration
Azalia [Auto]
PCHAzaliaConguration
Allows you to control the detection of the Azalia device. Conguration options:
[Auto] [Disabled]
5-16 Chapter 5: BIOS setup
Compatible Mode [Disabled]
This item only appears when you set the SATA Mode Selection to [IDE]. This item allows you
to enable or disable the Compatible mode. Conguration options: [Disabled] [Enabled]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
SATA Controller(s) [Enabled]
SATA Mode Selection [IDE]
Compatible Mode [Disabled]
S.M.A.R.T. Status Check [Enabled]
Serial SATA Port 0 HardDisk (250.0GB)
Software Preserve SUPPORTED
Serial SATA Port 1 HardDisk (250.0GB)
Software Preserve SUPPORTED
Serial SATA Port 2 HardDisk (250.0GB)
Software Preserve SUPPORTED
Serial SATA Port 3 HardDisk (250.0GB)
Software Preserve SUPPORTED
Serial SATA Port 4 HardDisk (250.0GB)
Software Preserve SUPPORTED
Serial SATA Port 5 ASUS DVD-E8 ATAPI
Software Preserve SUPPORTED
Determines how SATA
controller(s) operate.
5.4.4 SystemAgent(SA)Conguration
This allows you to change System Agent parameters.
VT-d [Enabled]
This allows you enable or disable the VT-d function on MCH. Conguration options: [Enabled]
[Disabled]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
System Agent Bridge Name Haswell
System Agent RC Version 1.0.0.0
VT-d Capability Supported
VT-d [Enabled]
Enable NB Card [Disabled]
BDAT ACPI Table Support [Disabled]
VGA Priority [Offboard]
Memory Conguration
Check to enable VT-d
function on MCH.
Enable NB CRID [Disabled]
This allows you enable or disable the NB CRID WorkAround. Conguration options: [Enabled]
[Disabled]
BDAT ACPI Table Support [Disabled]
This allows you enable or disable the support for the BDAT ACPI table. Conguration options:
[Enabled] [Disabled]
VGA Priority [Offboard]
This allows you to prioritize between the onboard and offboard video device to be found.
Conguration options: [Onboard] [Offboard]
ASUS RS300-E8 Series 5-17
MemoryConguration
This allows you to change memory information settings.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Memory Information
Memory RC Version 1.0.0.0
Memory Frequency 1067 MHz
Usage Memory 1024 MB (DDR3)
DIMM_A1 Not Present
DIMM_A2 1024 MB (DDR3)
DIMM_A3 Not Present
DIMM_A4 Not Present
CAS Latency (tCL) 7
Minimum delay time
CAS to RAS (tRCDmin) 7
Row Precharge (tRPmin) 7
Active to Precharge (tRASmin) 20
Memory Frequency Limiter [Auto]
ECC Support [Enabled]
Memory Scrambler [Enabled]
Memory Remap [Enabled]
GDXC Support [Disabled]
Maximum Memory
Frequency Selections
in MHz.
Memory Frequency Limiter [Auto]
This allows you to set the memory frequency in MHz. Conguration options: [Auto] [1333]
[1600]
ECC Support [Enabled]
This allows you to enable or disable the DDR ECC support. Conguration options: [Enabled]
[Disabled]
Memory Scrambler [Enabled]
This allows you to enable or disable the Memory Scrambler support. Conguration options:
[Enabled] [Disabled]
Memory Remap [Enabled]
This allows you to enable or disable the Memory Remap above 4G. Conguration options:
[Enabled] [Disabled]
GDXC Support [Disabled]
This allows you to enable or disable the GDXC feature. Conguration options: [Enabled]
[Disabled]
5-18 Chapter 5: BIOS setup
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
PCI Bus Driver Version V 2.05.02
PCI 64bit Resources Handling
Above 4G Decoding [Disabled]
PCI Common Settings
Load RT32 Image [Enabled]
PCI Express Settings
PCIE Slot Conguration
5.4.5 PCI Subsystem Settings
Allows you to congure PCI, PCI-X, and PCI Express Settings.
Above 4G Decoding [Disabled]
This item allows you to enable or disable 64-bit capable devices to be decoded in above
4G Address Space if your system supports 64-bit PCI decoding. Conguration Options:
[Disabled][Enabled]
Load RT32 Image [Enabled]
Allows you to enable or disable the RT32 Image Loading. Conguration Options:
[Disabled][Enabled]
PCI Express Settings
Allows you to change the settings of the PCI Express Devices.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
PCI Express Device Register Setting
PCI Express Device Register Settings
ASPM Support [Disabled]
WARNING: Enabling ASPM may cause some
PCIE devices to fail
ASPM Support [Disabled]
This item allows you to enable or disable support to Active State Power Management (ASPM).
ASPM is a power management protocol that is used to extend battey life. Conguration
options:
[Disabled] Disables ASMP
[Auto] BIOS auto congure
[Force L0s] Force all links to L0s State
ASUS RS300-E8 Series 5-19
PCIESlotConguration
Allows you to perform PCIE slot congurations.
PCIE Option Rom 3 - 6 [Enabled]
Allows you to enable or disable the PCIE slots. Conguration Options: [Disabled][Enabled]
PIKE Option Rom [Enabled]
Allows you to enable or disable the PIKE Option Rom. Conguration Options:
[Disabled][Enabled]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
PCIE Slot Conguration
PCIE3 Not Present
PCIE3 Option Rom [Enabled]
PCIE4 Not Present
PCIE4 Option Rom [Enabled]
PCIE5 Not Present
PCIE5 Option Rom [Enabled]
PCIE6 Not Present
PCIE6 Option Rom [Enabled]
PIKE Not Present
PIKE Option Rom [Enabled]
Enabled/Disabled PCIE3
Option Rom
5-20 Chapter 5: BIOS setup
5.4.6USBConguration
This allows you to make changes on the conguration settings of the USB.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Enables Legacy USB
support. AUTO option
disables legacy
support if no USB
devices are connected.
DISABLE option will
keep USB devices
available only for
EFI applications.
USB Conguration
USB Devices
1 mouse,2 Hubs
Legacy USB Support [Enabled]
USB3.0 Support [Enabled]
XHCI Hand-off [Enabled]
EHCI Hand-off [Disabled]
USB Mass Storage Driver Support [Enabled]
Port 60/64 Emulation [Enabled]
USB hardware delays and time-outs:
USB transfer time-out [20 sec]
Device reset time-out [20 sec]
Device power-up delay [Auto]
The USB Devices item shows the auto-detected values. If no USB device is detected, the
item shows None.
Legacy USB Support [Enabled]
Allows you to enable or disable the support for legacy USB devices. Setting to [Auto] allows
the system to detect the presence of USB devices at startup. If detected, the USB controller
legacy mode is enabled. If no USB device is detected, the legacy USB support is disabled.
Conguration options: [Disabled] [Enabled] [Auto]
USB3.0 Support [Enabled]
Enables or disables the USB3.0 (XHCI) controller support. Conguration options: [Disabled]
[Enabled]
XHCI Hand-off [Enabled]
This functions as a workaround for OSes without XHCI hand-off support. Conguration
options: [Disabled] [Enabled]
EHCI Hand-off [Enabled]
This functions as a workaround for OSes without EHCI hand-off support. Conguration
options: [Disabled] [Enabled]
USB Mass Storage Driver Support [Enabled]
This allows you to enable or disable the USB Mass Storage driver support. Conguration
options: [Disabled] [Enabled]
Port 60/64 Emulation [Enabled]
This allows you to enable the I/O port 60h/64h emulation support. This should be enabled for
the complete USB keyboard legacy support for non-USB aware OSes. Conguration options:
[Disabled] [Enabled]
ASUS RS300-E8 Series 5-21
Security Device Support [Disabled]
Allows you to enable or disable BIOS support for security devices. Conguration
options: [Disabled] [Enabled]
5.4.7 TPM
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Enables or Disables BIOS
support for security
device.O.S. will not
show Security Device. TCG
EFI protocol and INT1A
interface will not be
available.
Conguration
TPM Support [Disable]
Current Status Information
NO Security Device Found
USB transfer time-out [20 sec]
Allows you to select the USB transfer time-out value. Conguration options:
[1 sec] [5 sec] [10 sec] [20 sec]
Device reset time-out [20 sec]
Allows you to select the USB device reset time-out value. Conguration options:
[10 sec] [20 sec] [30 sec] [40 sec]
Device power-up delay [Auto]
This allows you to set the maximum time the device will take before it properly reports itself to
the Host Controller. Conguration options: [Auto] [Manual]
Enable Hibernation [Enabled]
Allows you to enable or disable the Hibernation feature (OS/S4 sleep state).
Conguration options: [Disabled] [Enabled]
ACPI Sleep State [Both S1 and S3 available for OS to choose from]
Allows you to set the ACPI Sleep state. Conguration options: [Suspend Disabled]
[S1 only (CPU Stop Clock)] [S3 only (Suspend to RAM)]
[Both S1 and S3 available for OS to choose from]
5.4.8 ACPI Settings
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
ACPI Settings
Enable Hibernation [Enabled]
ACPI Sleep State [Both S1 and S3 avai...]
Enables or Disables
System ability to
Hibernate (OS/S4 Sleep
State). This option may
not be effective with
some OS.
5-22 Chapter 5: BIOS setup
5.4.9 WHEA Support
WHEA [Enabled]
Allows you to enable or disable the Windows® Hardware Error Architecture (WHEA)
support.Congurationoptions:[Disabled][Enabled]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Enables or disable
Windows Hardware Error
Architecture.
WHEA Support [Enabled]
5.4.10 NCT6779DSuperIOConguration
SerialPort1/2Conguration
The sub-items in this menu allows you to set the parameters of the Serial Port 1 (COM1) and
the Serial Port 2 (COM2).
Serial Port [Enabled]
Allows you to enable or disable the serial port (COM 1/2). Conguration options: [Enabled]
[Disabled]
Change Settings [Auto]
This item only appears when you set the Serial Port to [Enabled]. This item allows you to
select the serial port base address. Conguration options:
[Auto]
[IO=3F8h; IRQ=4]
[IO=3F8h: IRQ=3, 4, 5, 6, 7, 10, 11, 12]
[IO=2F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12]
[IO=3E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12]
[IO=2E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12]
[IO=2E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Set Parameters of
Serial Port 1 (COM1)
NCT6779D Super IO Conguration
Serial Port 1 Conguration
Serial Port 2 Conguration
Parallel Port Conguration
ASUS RS300-E8 Series 5-23
Parallel Port Configuration
The sub-items in this menu allow you to set the parallel port conguration.
Parallel Port [Enabled]
Allows you to enable or disable the parallel port (LPT/LPTE). Conguration options:
[Enabled] [Disabled]
Change Settings [Auto]
Allows you to select the optimal setting for the super IO device.
Conguration options: [Auto] [IO=378h; IRQ=5] [IO=378h: IRQ=5, 6, 7, 10, 11, 12]
[IO=278h; IRQ=5, 6, 7, 10, 11, 12] [IO=3BCh; IRQ=5, 6, 7, 10, 11, 12]
Device Mode [STD Printer Mode]
Allows you to select the printer port mode. Conguration options: [STD Printer mode]
[SPP Mode] [EPP-1.9 and SPP Mode] [EPP-1.7 and SPP Mode]
[ECP Mode] [ECP and EPP 1.9 Mode] [ECP and EPP 1.7 Mode]a
5.4.11 Intel Server Platform Services
This item displays the information of the Intel Server Platform Services congured
in the system.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Intel Sever Platform Services Conguration
ME BIOS Interface Ver : 1.0
SPS Version 3.0.4.162
ME FW Status Value : 0xf0345
ME FW State : SPS ME FW Active
ME FW Operation State : M0 without UMA
ME FW Error Code : No Error
ME NM FW Status Value : 0x80000001
BIOS Booting Mode : Power Optimized Mode
Cores Disabled : 0
ME FW SKU Information : Node Manager
End-of-POST Status : EOP disabled in POST
5-24 Chapter 5: BIOS setup
5.4.12 OnboardLANConguration
This allows you to change the enable or disable the onboard LAN.
INTEL I210 LAN1 - LAN4 Enable [Enabled]
Allows you to enable or disable the INTEL I210 LAN function in the system. Conguration
Options: [Enabled] [Disabled]
INTEL I210 LAN1/LAN2 OpROM [PXE], INTEL I210 LAN3/LAN4 OpROM
[Disabled]
Allows you to launch the Intel I210 LAN OpROM. Conguration options: [Disabled] [PXE]
[iSCSI]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
INTEL I210 LAN
Disable/Enable
INTEL I210 LAN1 Enable [Enabled]
INTEL I210 LAN1 OpROM [PXE]
INTEL I210 LAN2 Enable [Enabled]
INTEL I210 LAN2 OpROM [PXE]
INTEL I210 LAN3 Enable [Enabled]
INTEL I210 LAN3 OpROM [Disabled]
INTEL I210 LAN4 Enable [Enabled]
INTEL I210 LAN4 OpROM [Disabled]
Onboard LAN Conguration
INTEL I210 LAN1 MAC: 00:E0:18:10:18:E8
INTEL I210 LAN2 MAC: 00:E0:18:10:18:E9
INTEL I210 LAN3 MAC: 00:E0:18:10:18:EA
INTEL I210 LAN4 MAC: 00:E0:18:10:18:EB
5.4.13 MIOCardConguration
This item allows you to set MIO Card conguration settings.
Front Panel Type [AC97]
Allows you to select the front Panel type of the MIO. Conguration options:
[AC97] [HD]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
MIO Card Type
Set MIO Card
MIO Card Type [ALC 892]
Front Panel Type [AC97]
ASUS RS300-E8 Series 5-25
COM1/COM2 Console Redirection [Disabled/Enabled]
Allows you to enable or disable the console redirection feature. Conguration options:
[Disabled] [Enabled]
The Console Redirection Settings becomes congurable when Console Redirection is
set to [Enabled].
5.4.14 Serial Port Console Redirection
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Console Redirection
Enable or Disable.
COM1
Console Redirection [Disabled]
Console Redirection Settings
COM2
Console Redirection [Enabled]
Console Redirection Settings
Serial Port for Out-of-Band Management/
Windows Emergency Management Services (EMS)
Console Redirection [Disabled]
Console Redirection Settings
COM1/COM2 Console Redirection Settings
The settings specify how the host computer and the remote computer (which the user is
using) will exchange data. Both computers should have the same or compatible settings.
Terminal Type [VT-UTF8]
Allows you to set the terminal type.
[VT100] ASCII char set.
[VT100+] Extends VT100 to support color, function keys, among others
[VT-UTF8] Uses UTF8 encoding to map Unicode chars onto 1 or more bytes
[ANSI] Extended ASCII char set
Bits per second [57600]
Selects serial port transmission speed. The speed must be matched on the other side. Long
or noisy lines may require lower speeds. Conguration options: [9600] [19200] [38400]
[57600] [115200]
Data Bits [8]
Allows you to set the data bits. Conguration options: [7] [8]
Parity [None]
Allows you to select the parity bit. A parity bit is sent with the data bits to detect transmission
errors. Conguration options: [None] [Even] [Odd] [Mark] [Space]
Stop Bits [1]
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.) The
standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop
bit. Conguration options: [1] [2]
5-26 Chapter 5: BIOS setup
Flow Control [Hardware RTS/CTS]
Flow control can prevent data loss from buffer overow. When sending data, if the receiving
buffers are full, a “stop” signal can be sent to stop the data ow. Once the buffers are empty,
a “start” signal can be sent to re-start the ow. Hardware ow control uses two wires to send
start/stop signals. Conguration options: [None] [Hardware RTS/CTS]
VT -UTF8 Combo Key Support [Enabled]
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100 terminals.
Conguration options: [Disabled] [Enabled]
Recorder Mode [Disabled]
This allows you to enable or disable the Recorded mode to capture Terminal data.
Conguration options: [Disabled] [Enabled]
Resolution 100x31 [Enabled]
This allows you to enable or disable the extended terminal resolution. Conguration options:
[Disabled] [Enabled]
Legacy OS Redirection Resolution [80x24]
This allows you to set the number of rows and columns supported on the Legacy OS.
Conguration options: [80x24] [80x25]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty. Conguration options:
[VT100] [LINUX] [XTERMR6] [SCO] [ESCN] [VT400]
Redirection After BIOS POST [Bootloader]
This setting allows you to specify if Bootloader is selected than Legacy console redirection.
Conguration options: [Always Enable] [Bootloader]
ASUS RS300-E8 Series 5-27
5.4.16 APM
Allows you to congure the Advance Power Management (APM) settings.
Restore AC Power Loss [Last State]
Allows you to set the state the system will go to after an AC power loss. Conguration
options: [Power Off] [Power On] [Last State]
Power On By PCI [Disabled]
You can use this option to enable or disable the Wake-on-LAN feature of the Intel® LAN.
Conguration options: [Disabled] [Enabled]
Power On By PCIE [Disabled]
This allows you to enable or diasble the PCIE devices to generate a wake event.
Conguration options: [Disabled] [Enabled]
Power On By RTC [Disabled]
This item allows you to enable or disable RTC to generate a wake event. When set to
[Enabled], the items RTC Alarm Date (Days) and Hour/Minute/Second becomes user-
congurable where you can set values.
EUP Ready [Disabled]
This item allows you to switch off some power at S5 to get the system ready for EuP
requirement. Conguration options: [Enabled] [Disabled]
5.4.15 Runtime Error Logging Support
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Runtime Error Logging Support [Disabled]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Restore AC Power Loss [Last State]
Power On By PCI [Disabled]
Power On By PCIE [Disabled]
Power On By RTC [Disabled]
EuP Ready [Disabled]
Specify what state
to go to when power
is re-applied after
a power failure (G3
state).
Runtime Error Logging Support [Disabled]
Allows you to enable or disable the Runtime Error Logging Support. Conguration options:
[Disabled] [Enabled]
5-28 Chapter 5: BIOS setup
Network stack [Disable]
Enables or disables the network stack feature. Conguration options: [Disable]
[Enable]
5.4.18 Intel RC Drivers Version Detail
This item displays the Version String for the Intel RC Drivers.
5.4.17 Network Stack
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Network stack [Disable] Enable/Disable the
network stack (Pxe
and UEFI)
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Advanced
Intel CPU RC Version 1.0.0.0
Memory RC Version 1.0.0.0
Intel SA RC Version 1.0.0.0
Intel PCH RC Version 1.0.0.0
ASUS RS300-E8 Series 5-29
5.5 Event Logs menu
The Event Logs menu items allow you to change the event log settings and view
the system event logs.
Smbios Event Log [Enabled]
Allows you to enable or disable all features of Smbios event logging during boot.
Conguration options: [Disabled] [Enabled]
Erase Event Log [No]
This item only appears when Smbios Event Log is set to [Enabled]. This item allows you to
select the options for erasing Smbios event log. Conguration options: [No] [Yes, Next reset]
[Yes, Every reset]
When Log is Full [Do Nothing]
This item only appears when Smbios Event Log is set to [Enabled]. This item allows you to
select the options for reaction when the event logs are full. Conguration options:
[Do Nothing] [Erase Immediately]
Change Smbios Event Log Settings
Change this to enable or
disable all features of
Smbios Event Logging during
boot.
Enabling/Disabling Options
Smbios Event Log [Enabled]
Erasing Settings
Erase Event Log [No]
When Log is Full [Do Nothing]
NOTE: All values changed here do not take effect
until computer is restarted.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Event Logs
Press <Enter> to change
the Smbios Event Log
conguration.
Change Smbios Event Log Settings
View Smbios Event Log
View System Event Log
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Event Logs
5-30 Chapter 5: BIOS setup
5.6 Boot menu
The items in Boot menu allows you to change the options on how the system will
boot.
Setup Prompt Timeout [xx]
This item allows you to adjust the number of seconds to wait for setup activation key. Use the
<+> and <-> keys to specify the values.
Bootup NumLock State [On]
Allows you to select the power-on state for the NumLock. Conguration options: [Off] [On]
Full Screen Logo [Enabled]
Allows you to enable or disable the full screen logo display feature. Conguration options:
[Disabled] [Enabled].
Set the Full Screen Logo to [Enabled] to use the ASUS MyLogo2™ feature.
GateA20 Active [Upon Request]
This item is useful when any RT code is execute above 1MB. When set to [Upon Request],
the GA20 can be disabled using BIOS services. When set to [Always], disabling of GA20 is
not allowed. Conguration options: [Upon Request] [Always].
Option ROM Messages [Force BIOS]
Allows you to set the display mode for Option ROM. Conguration options:
[Force BIOS] [Keep Current]
Number of seconds to wait
for setup activation key.
65535(0xFFFF) means
indenite waiting.
Boot Conguration
Setup Prompt Timeout 1
Bootup NumLock State [On]
Full Screen Logo [Enabled]
CSM16 Module Version 07.69
GateA20 Active [Upon Request]
Option ROM Messages [Force BIOS]
INT19 Trap Response [Immediate]
Boot Device Seeking [Endless PXE]
Boot Option Priorities
Boot Option #1 [P0: DVD ]
Boot Option #2 [P4: Harddisk 2.50G]
Boot Option #3 [Windows Boot Man..]
Network Device BBS Priorities
Hard Drive BBS Priorities
CSM parameters
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Boot
ASUS RS300-E8 Series 5-31
INT19 Trap Response [Immediate]
This item allows you to set the BIOS reaction on INT19 trapping by Option ROM.
Conguration options: [Immediate] [Postponed]
Boot Device Seeking [Endless PXE]
This allows you to enable the Boot Device Seeking option. Conguration options:
[Endless PXE] Continuosly seek remote boot image until boot image is found or
the operation is aborted <Ctrl>+<Alt>+<Del> is pressed by the user).
[Normal] Seek remote boot image once then stop.
Boot Option Priorities
These items specify the boot device priority sequence from the available devices. The number
of device items that appears on the screen depends on the number of devices installed in the
system.
Network Device BBS Priorities / Hard Drive BBS Priorities
This allows you to set the order of the legacy devices in this group.
• To select the boot device during system startup, press <F8> when ASUS Logo
appears.
• To access Windows® OS in Safe Mode, do any of the following:
- Press <F5> when ASUS Logo appears.
- Press <F8> after POST.
5-32 Chapter 5: BIOS setup
This option controls if
CSM will be launched.
Launch CSM [Enabled]
Boot Option lter [Legacy only]
Launch PXE OpROM policy [Legacy only]
Launch Storage OpRom policy [Legacy only]
Launch Video OpRom policy [Legacy only]
Other PCI device ROM priority [Legacy OpROM]
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Boot
CSM Parameters
This allows you to set OpROM execution, boot options lter, and other OpROM settings
settings.
Launch CSM [Enabled]
This option allows you to enable or disable the launch of CSM. Conguration options:
[Disabled] [Enabled]
Boot Option filter [Legacy only]
This option allows you to control what devices the system can boot to. Conguration options:
[UEFI and Legacy] [Legacy only] [UEFI only]
Launch PXE OpROM policy [Legacy only]
This option allows you to control the execution of UEFI and Legacy PXE OpROM.
Conguration options: [Do not launch] [UEFI only] [Legacy only] [Legacy rst] [UEFI rst]
Launch Storage OpROM policy [Legacy only]
This option allows you to control the execution of UEFI and Legacy Storage OpROM.
Conguration options: [Do not launch] [UEFI only] [Legacy only] [Legacy rst] [UEFI rst]
Launch Video OpROM policy [Legacy only]
This option allows you to control the execution of UEFI and Legacy Storage OpROM.
Conguration options: [Do not launch] [UEFI only] [Legacy only] [Legacy rst] [UEFI rst]
Other PCI device ROM priority [Legacy OpROM]
This option allows you to control the execution of UEFI and Legacy Storage OpROM.
Conguration options: [UEFI OpROM] [Legacy OpROM]
ASUS RS300-E8 Series 5-33
5.7 Monitor menu
The Monitor menu displays the system temperature/power status, and allows you
to change the fan settings.
CPU/MB/TR1 Temperature [xxxºC/xxxºF]
The onboard hardware monitor automatically detects and displays the CPU and motherboard
component temperatures.
CPU_FAN1 Speed; FRNT_FAN1–3 Speed; REAR_FAN1 Speed [xxxx RPM] or
[Ignore] / [N/A]
The onboard hardware monitor automatically detects and displays the speed of CPU fans,
front fans, and rear fan in rotations per minute (RPM). If the fan is not connected to the
motherboard, the eld shows N/A.
VCORE1 Voltage: +12V, +5V, +VDDQ, +3VSB, +3.3V, and VBAT
The onboard hardware monitor automatically detects the voltage output through the onboard
voltage regulators.
Fan Speed Control [Generic Mode]
Allows you to congure the ASUS Smart Fan feature that smartly adjusts the fan speeds for
more efcient system operation. Conguration options:
[Low Speed Mode] [Generic Mode] [High Speed Mode] [Full Speed Mode]
Whisper/Generic/High/
Speed/Full Speed
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Monitor
CPU Temperature : +58ºC/ +162ºF
MB Temperature : +52ºC/ +151ºF
TR1 Temperature : N/A
CPU_FAN1 Speed : 1054 RPM
REAR_FAN1 Speed : N/A
FRNT_FAN1 Speed : N/A
FRNT_FAN2 Speed : N/A
FRNT_FAN3 Speed : N/A
VCORE1 : +1.800 V
+12V : +12.288 V
+5V : +5.040 V
+VDDQ : +1.504 V
+3VSB : +3.408 V
+3.3V : +1.296 V
VBAT : +3.344 V
FAN Speed Control [Generic Mode]
5-34 Chapter 5: BIOS setup
5.8 Security
This menu allows a new password to be created or a current password to be
cchanged. The menu also enables or disables the Secure Boot state and lets the
user congure the System Mode state.
Set Setup Administrator
Password
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Security
Administrator Password
User Password
Clear Password
System Boot Menu
HDD Security Conguration:
P1: HardDisk
P2: HardDisk
Administrator Password
To set an administrator password:
1. Select the Administrator Password item and press <Enter>.
2. From the Create New Password box, key in a password, then press <Enter>.
3. Conrm the password when prompted.
To change an administrator password:
1. Select the Administrator Password item and press <Enter>.
2. From the Enter Current Password box, key in the current password, then
press <Enter>.
3. From the Create New Password box, key in a new password, then press
<Enter>.
4. Conrm the password when prompted.
To clear the administrator password, follow the same steps as in changing an administrator
password, but press <Enter> when prompted to create/conrm the password.
Password Description
If ONLY the Administrator’s password is set, then
this only limits access to Setup and is only asked
for when entering Setup.
If ONLY the User’s password is set, then this
is a power on password and must be entered to
boot or enter Setup. In Setup the User will have
Administrator rights.
The password length must be
in the following range:
Minimum length 3
Maximum length 20
ASUS RS300-E8 Series 5-35
User Password
To set a user password:
1. Select the User Password item and press <Enter>.
2. From the Create New Password box, key in a password, then press <Enter>.
3. Conrm the password when prompted.
To change a user password:
1. Select the User Password item and press <Enter>.
2. From the Enter Current Password box, key in the current password, then
press <Enter>.
3. From the Create New Password box, key in a new password, then press
<Enter>.
4. Conrm the password when prompted.
To clear a user password:
1. Select the Clear User Password item and press <Enter>.
2. Select Yes from the Warning message window then press <Enter>.
Secure Boot Menu
This item allows you to customize the Secure Boot settings.
Secure Boot Control [Enabled]
This item allows you to enable or disable the Secure Boot ow control. Conguration options:
[Disabled] [Enabled]
Secure Boot Mode [Standard]
This item allows you to select the mode of the Secure boot to change Execution policy and
Secure Boot Key management. Conguration options: [Standard] [Custom]
Secure Boot ow control.
Secure Boot can be
enabled only when
Platform Key (PK) is
enrolled and Platform is
operating in User mode.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Security
Platform Mode Setup
Secure Boot Disabled
Secure Boot Control [Enabled]
Secure Boot Mode [Standard]
Image Execution Policy
Key Management
5-36 Chapter 5: BIOS setup
Internal FV [Always Execute]
Conguration options: [Always Execute]
Option ROM/Removable Media/Fixed Media [Deny Execute]
Conguration options: [Always Execute] [Always Deny] [Allow Execute] [Defer Execute]
[Deny Execute] [Query User]
Key Management
This item only appears when you set the Secure Boot Mode to [Custom]. This allows you to
modify Secure Boot variables and set Key Management page.
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Security
Image Execution Policy
per device path on
Security Violation.
Interval FV [Always Execute]
Option ROM [Deny Execute]
Removable Media [Deny Execute]
Fixed Media [Deny Execute]
Image Execution Policy
This item only appears when you set the Secure Boot Mode to [Custom]. This
allows you to manage the Image Policy on Security Violation.
Install Factory default
Secure Boot Keys when
System is in Setup Mode
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Security
Factory Default Key Provisioning [Disabled]
Install All Factory Default Keys
Platform Key (PK) NOT INSTALLED
Set new PK
Delete PK
Key Exchange Key Database (KEK) NOT INSTALLED
Set new KEK
Delete KEK
Append Var to KEK
Authorized Signature Database (DB) NOT INSTALLED
Set new DB
Delete DB
Append Var to DB
Forbidden Signature Database (DBX) NOT INSTALLED
Set new DBX
Delete DBX
Append Var to DBX
Factory Default Key Provisioning [Disabled]
Conguration options: [Disabled] [Enabled]
Install All Factory Default Keys
This item will ask you if you want to Install Factory Default secure variables. Select Yes if you
want to load the default secure variables, otherwise select No.
Platform Key (PK)/Key Exchange Key Database (KEK)/Authorized Signature Database
(DB)/ Forbidden Signature Database (DBX)
Conguration options: [Set New] [Delete] [Append]
ASUS RS300-E8 Series 5-37
5.10 Exit menu
The Exit menu items allow you to save or discard your changes to the BIOS items.
Pressing <Esc> does not immediately exit this menu. Select one of the options from this menu
or <F10> from the legend bar to exit.
Discard Changes & Exit
This option allows you to exit the Setup program without saving your changes.
When you select this option or if you press <Esc>, a conrmation window appears.
Select Yes to discard changes and exit.
Save Changes & Reset
Once you are nished making your selections, choose this option from the Exit
menu to ensure the values you selected are saved. When you select this option or
if you press <F10>, a conrmation window appears. Select Yes to save changes
and exit.
Start EzFlash utility
Allows you to run the Start EzFlash utility. For more information, see section
4.1.2 ASUS EzFlash utility.
5.9 Tool menu
The Tool menu items allow you to congure options for special functions. Select an
item then press <Enter> to display the submenu.
Press ENTER to run the
utility to select and
update BIOS.
Start EzFlash
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Tool
Exit system setup without
saving any changes.
Discard Changes & Exit
Save Changes & Reset
Discard Changes & Reset
Restore Defaults
Boot Override
IBA GE Slot 0B00 v1404
IBA GE Slot 0B00 v1404
Windows Boot Manager
Launch EFI Shell from lesystem device
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.
Main Advanced Event Logs Boot Monitor Security Tool Exit
Exit
5-38 Chapter 5: BIOS setup
Discard Changes & Reset
This option allows you to reset without saving your changes. When you select this
option or if you press <ENTER>, a conrmation window appears. Select Yes to
discard changes and reset.
Restore Defaults
This option allows you restore or load the default values for all the setup options.
When you select this option or if you press <ENTER>, a conrmation window
appears. Select Yes to apply the default values or press <Esc> to exit.
LaunchEFIShellfromlesystemdevice
This option allows you to launch the EFI Shell application (shellx64.e) from one of
the available lesystem devices. Select Yes to proceed, or No to cancel, and then
press <Enter>.
This chapter provides instructions for
setting up, creating and conguring RAID
sets using the available utilities.
Chapter 6
RAIDconguration
6-2 Chapter 6: RAID conguration
6.1 Setting up RAID
The motherboard comes with the Intel® C224 controller that supports the Intel®
Rapid Storage Technology enterprise Option ROM Utility with RAID 0, RAID 1,
RAID 10, and RAID 5 support (for Windows® OS only).
6.1.1 RAIDdenitions
RAID 0
(Data striping)
optimizes two identical hard disk drives to read and write
data in parallel, interleaved stacks. Two hard disks perform the same work as a
single drive but at a sustained data transfer rate, double that of a single disk alone,
thus improving data access and storage. Use of two new identical hard disk drives
is required for this setup.
RAID 1 (Data mirroring) copies and maintains an identical image of data from one
drive to a second drive. If one drive fails, the disk array management software
directs all applications to the surviving drive as it contains a complete copy of
the data in the other drive. This RAID conguration provides data protection and
increases fault tolerance to the entire system. Use two new drives or use an
existing drive and a new drive for this setup. The new drive must be of the same
size or larger than the existing drive.
RAID 10 is data striping and data mirroring combined without parity (redundancy
data) having to be calculated and written. With the RAID 10 conguration you get
all the benets of both RAID 0 and RAID 1 congurations. Use four new hard disk
drives or use an existing drive and three new drives for this setup.
RAID 5 stripes both data and parity information across three or more hard disk
drives. Among the advantages of RAID 5 conguration include better HDD
performance, fault tolerance, and higher storage capacity. The RAID 5 conguration
is best suited for transaction processing, relational database applications,
enterprise resource planning, and other business systems. Use a minimum of three
identical hard disk drives for this setup.
If you want to boot the system from a hard disk drive included in a created RAID
set, copy rst the RAID driver from the support DVD to a oppy disk before you
install an operating system to the selected hard disk drive.
ASUS RS300-E8 Series 6-3
6.1.4 Setting the RAID mode in BIOS
You must set the RAID mode in the BIOS Setup to be able to launch the RAID
utilities before you can create a RAID set from the SATA hard disk drives attached
to the SATA connectors supported by Intel® C224 chipset.
To do this:
1. Enter the BIOS Setup during POST.
2. Go to the Advanced Menu > SATAConguration, then press <Enter>.
3. Set SATA Mode to [RAID].
4. Press <F10> to save your changes and exit the BIOS Setup.
Refer to Chapter 4 for details on entering and navigating through the BIOS
Setup.
6.1.5 RAIDcongurationutilities
Depending on the RAID connectors that you use, you can create a RAID set using
the utilities embedded in each RAID controller. For example, use the Intel® Rapid
Storage Technology enterprise SATA Option ROM Utility if you installed Serial
ATA hard disk drives on the Serial ATA connectors supported by the Intel® C224
chipset.
6.1.2 Installing hard disk drives
The motherboard supports Serial ATA for RAID set conguration. For optimal
performance, install identical drives of the same model and capacity when creating
a disk array.
To install the SATA hard disks for RAID conguration:
1. Install the SATA hard disks into the drive bays following the instructions in the
system user guide.
2. Connect a SATA signal cable to the signal connector at the back of each drive
and to the SATA connector on the motherboard.
3. Connect a SATA power cable to the power connector on each drive.
6.1.3 Setting Jumpers
Ensure to turn off power before setting the jumpers on the motherboard.
You must set the jumper settings of your motherboard to activate the embedded Intel®
Rapid Storage Technology enterprise SATA Option ROM Utility.
To set the jumper settings for Intel® Rapid Storage Technology enterprise SATA
Option ROM Utility, set the 3-pin RAID_SEL1 jumper to pins 2-3.
For more information about the jumper settings of 3-pin RAID_SEL1, you may refer
to the RAIDcongurationutility section on page 2-27.
6-4 Chapter 6: RAID conguration
6.2 Intel® Rapid Storage Technology
enterprise SATA Option ROM Utility
The Intel® Rapid Storage Technology enterprise SATA Option ROM utility allows
you to create
RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard
disk drives that are connected to the Serial ATA connectors supported by the
Southbridge.
The navigation keys at the bottom of the screen allow you to move through the
menus and select the menu options.
The RAID BIOS setup screens shown in this section are for reference only and
may not exactly match the items on your screen.
To launch the Intel® Rapid Storage Technology enterprise SATA Option ROM utility:
1. Turn on the system.
2. During POST, press <Ctrl>+<I> to display the utility main menu.
Before you proceed, ensure that you have installed the Serial ATA hard disk
drives, have set the correct jumper settings of the motherboard, and have
set the correct SATA mode in the BIOS setup. You can refer to sections 5.1.2
Installing hard disk drives, 5.1.3 Setting Jumpers, and 5.1.4 Setting the
RAID mode in BIOS for more information.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes:
None defined.
Physical Disks:
ID Drive Model Serial # Size Type/Status(Vol ID)
0 ST3300656SS HWAS0000991753TR 279.3GB Non-RAID Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Non-RAID Disk
2 ST3300656SS 397600009846UEDY 279.3GB Non-RAID Disk
3 ST3300656SS GWC50000991756G6 279.3GB Non-RAID Disk
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
ASUS RS300-E8 Series 6-5
6.2.1 Creating a RAID set
To create a RAID set:
1. From the utility main menu, select 1. Create RAID Volume and press
<Enter>.
2. Key in a name for the RAID set from the following screen and press <Enter>.
3. Press the up/down arrow keys to select a RAID Level that you wish to create
then press <Enter>.
4. From the Disks item eld, press <Enter> to select the hard disk drives that you
want to include in the RAID set.
5. Use the up/down arrow keys to move the selection bar then press <Space>
to select a disk. A small triangle before the Port number marks the selected
drive. Press <Enter> when you are done.
[ESC]-Previous Menu [ENTER]-Select[ ]Change
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
[ HELP ]
Name:
RAID Level:
Disks:
Strip Size:
Capacity:
Syne:
Create Volume
Enter a unique volume name that has no special characters and is
16 characters or less.
Volume0
RAID0(Strips)
Select Disks
128KB
0.0 GB
N/A
[TAB]-Next
[ SELECT DISKS ]
Port Drive Model Serial # Size Status
0 ST3300656SS HWAS0000991753TR 279.3GB Non-RAID Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Non-RAID Disk
2 ST3300656SS 397600009846UEDY 279.3GB Non-RAID Disk
3 ST3300656SS GWC50000991756G6 279.3GB Non-RAID Disk
Select 2 disks to create volume.
[ ]-Prev/Next [TAB]-(M)aster [SPACE]-(R)ecovery [ENTER]-Done
6-6 Chapter 6: RAID conguration
6. Use the up/down arrow keys to select the stripe size for the RAID array (for
RAID 0, 10 and 5 only) then press <Enter>. The available stripe size values
range from 4 KB to 128 KB. The following are typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
We recommend a lower stripe size for server systems, and a higher stripe size
for multimedia computer systems used mainly for audio and video editing.
7. In the Capacity eld item, key in the RAID volume capacity that you want to
use and press <Enter>. The default value indicates the maximum allowed
capacity.
8. Press <Enter> to start creating the RAID volume.
9. From the following warning message, press <Y> to create the RAID volume
and return to the main menu, or press <N> to go back to the CREATE
VOLUME menu
WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
Are you sure you want to create this volume? (Y/N):
ASUS RS300-E8 Series 6-7
6.2.2 Deleting a RAID set
Take caution when deleting a RAID set. You will lose all data on the hard disk
drives when you delete a RAID set.
To delete a RAID set:
1. From the utility main menu, select 2. Delete RAID Volume and press
<Enter>.
2. From the Delete Volume Menu, press the up/down arrow keys to select the
RAID set you want to delete then press <Del>.
3. From the following warning message, press <Y> to delete the RAID set and
return to the utility main menu, or press <N> to return to the DELETE VOLUME
menu.
[ESC]-Previous Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ DELETE VOLUME MENU ]
[ HELP ]
Deleting a volume will reset the disks to non-RAID
WARNING: ALL DISK DATA WILL BE DELETED.
(This does not apply to Recovery volumes)
[DEL]-Delete Volume
Name Level Drives Capacity Status Bootable
Volume0 RAID0(Stripe) 2 298.0GB Normal Yes
ALL DATA IN THE VOLUME WILL BE LOST!
(This does not apply to Recovery volumes)
Are you sure you want to delete volume “Volume0”? (Y/N):
[DELETE VOLUME VERIFICATION ]
6-8 Chapter 6: RAID conguration
6.2.3 Resetting disks to Non-RAID
Take caution before you reset a RAID volume hard disk drive to non-RAID.
Resetting a RAID volume hard disk drive deletes all internal RAID structure on
the drive.
To reset a RAID set hard disk drive:
1. From the utility main menu, select 3. Reset Disks to Non-RAID and press
<Enter>.
2. Press the up/down arrow keys to select the drive(s) or disks of the RAID set
you want to reset, then press <Space>. A small triangle before the Port number
marks the selected drive. Press <Enter> when you are done.
3. Press <Y> in the conrmation window to reset the drive(s) or press <N> to return
to the utility main menu.
Port Drive Model Serial # Size Status
0 ST3300656SS HWAS0000991753TR 279.3GB Member Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Member Disk
Select the disks that should be reset.
Resetting RAID disk will remove its RAID structures
and revert it to a non-RAID disk.
[ ]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
[RESET RAID DATA ]
WARNING: Resetting a disk causes all data on the disk to be lost.
(This does not apply to Recovery volumes)
ASUS RS300-E8 Series 6-9
Select a destination disk with the same size as the original hard disk.
6.2.5 Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system
displays the status of the RAID volume as “Degraded” during POST. You can
rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. During POST, press <Ctrl>+<I> at the prompt to enter the Intel Rapid Storage
Technology option ROM utility.
2. If there is a non-RAID SATA Hard Disk available, the utility will prompt you to
rebuild the RAID. Press the up/down arrow keys to select the destination disk
then Press <Enter> to start the rebuilding process or press <ESC> to exit.
6.2.4 Exiting the Intel® Rapid Storage Technology
enterprise SATA Option ROM utility
To exit the utility:
1. From the utility main menu, select 4. Exit then press <Enter>.
2. From the following warning message, press <Y> to exit or press <N> to return
to the utility main menu.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XXX.GB
“Degraded” volume and disk available for rebuilding detected. Selectign
a disk initiates a rebuild. Rebuild completes in the operating system.
[ ]-Previous/Next [ENTER]-Select [ESC]-Exit
[DEGRADED VOLUME DETECTED ]
Are you sure you want to exit? (Y/N):
[CONFIRM EXIT ]
6-10 Chapter 6: RAID conguration
3. The utility immediately starts rebuilding after the disk is selected. The status of
the degraded RAID volume is changed to “Rebuild”.
4. Exit Intel Rapid Storage Technology and reboot the system.
5. Select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console
or click the Intel Rapid Storage Technology tray icon to load the Intel Rapid
Storage Manager utility.
6. From the View menu, select Advanced Mode to display the details of the Intel
Rapid Storage Console.
7. From the Volumes view option, select RAID volume to view the rebuilding
status. When nished, the status is changed to “Normal”.
Rebuilding the RAID with a new hard disk
If any of the SATA hard disk drives included in the RAID array failed, the system
displays the status of the RAID volume as “Degraded” during POST. You may
replace the disk drive and rebuild the RAID array.
To rebuild the RAID with a new hard disk:
1. Remove the failed SATA hard disk and install a new SATA hard disk of the same
specication into the same SATA Port.
Select a destination disk with the same size as the original hard disk.
2. Reboot the system then follow the steps in section Rebuilding the RAID with
other non-RAID disk.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes: *=Data is Encrypted
ID Name Level1 Strip Size Status Bootable
1 Volume0 RAID1(Mirror) N/A 149.0GB Rebuild Yes
Physical Devices:
Port Drive Model Serial # Size Type/Status(Vol ID)
1 ST3160812AS 9LS0F4HL 149.0GB Member Disk(0)
2 ST3160812AS 3LS0JYL8 149.0GB Member Disk(0)
Volumes with “Rebuild” status will be rebuilt within the operating system.
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
ASUS RS300-E8 Series 6-11
6.2.6 Setting the Boot array in the BIOS Setup Utility
You can set the boot priority sequence in the BIOS for your RAID arrays when
creating multi-RAID using the Intel® Rapid Storage Technology enterprise SATA
Option ROM utililty.
To set the boot array in the BIOS:
Set at least one of the arrays bootable to boot from the hard disk.
1. Reboot the system and press <Del> to enter the BIOS setup utility during
POST.
2. Go to the Boot menu and select the boot option priority.
3. Use up/down arrow keys to select the boot priority and press <Enter>. See the
Boot menu section of Chapter 4 for more details.
4. From the Exit menu, select Save Changes & Exit, then press <Enter>.
6-12 Chapter 6: RAID conguration
6.3 Intel® Rapid Storage Technology
enterprise (Windows)
The Intel® Rapid Storage Technology enterprise allows you to create RAID 0,
RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives
that are connected to the Serial ATA connectors supported by the Southbridge.
You can click Rescan to re-scan any attached hard disks.
1. Turn on the system to windows desktop.
2. Click the Intel® Rapid Storage Technology enterprise icon to display the main
menu.
Your storage system is congured for data protection, increased performance
and optimal data storage capacity. You can create additional volumes to further
optimize your storage system.
To enter the Intel® Rapid Storage Technology enterprise utility under Windows
operating system:
You need to manually install the Intel® Rapid Storage Technology enterprise
utility on a Windows® operating system. Please refer to the installation
instructions in Chapter 6.
ASUS RS300-E8 Series 6-13
6.3.1 Creating a RAID set
To create a RAID set:
1. From the utility main menu, select Create Volume and select volume type.
2. Click Next.
3. Enter a name for the RAID set, then select the array disks.
4. Select Volume Size tab, you can drag the bar to decide the volume size.
5. Click Next.
• If you do not want to keep the data on one of the selected disks, select NO
when prompted.
• If you want to Enable volume write-back cache or Initialize volume, click
Advanced.
6-14 Chapter 6: RAID conguration
6. Conrm the volume creation, than click Create Volume to continue.
This process could take a while depending on the number and size of the disks.
You can continue using other applications during this time.
7. Wait until the process is completed, then click OK when prompted.
You still need to partition your new volume using Windows Disk Management
before adding any data.
The RAID set is displayed in the Volumes list and you can change the settings in
Volume Properties.
ASUS RS300-E8 Series 6-15
6.3.2 Changing a Volume Type
To change the volume type in Volume Properties:
1. Click the SATA array items you want to change in Volumes eld.
2 From the Volume Properties eld, select Type:RAID 1 Change type.
We recommend a lower stripe size for server systems, and a higher stripe size for
multimedia computer systems used mainly for audio and video editing.
3. You can change the Name, Select the new volume type, and Select additional
disks to include in the new volume if needed.
4. Select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only),
and click OK. The available stripe size values range from 4 KB to 128 KB.
The following are typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
6-16 Chapter 6: RAID conguration
6.3.3 Deleting a volume
Be cautious when deleting a volume. You will lose all data on the hard disk
drives.Before you proceed, ensure that you back up all your important data from
your hard drives.
To delete a volume:
1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes
eld you want to delete.
3. Click Yes to delete the volume and return to the utility main menu, or click No
to return to the main menu.
2. Select Delete volume in Volume Properties eld. The following screen
appears.
ASUS RS300-E8 Series 6-17
6.3.4 Preferences
System Preferences
Allow you to set to show the notication area icon and show system information, warning, or
errors here.
E-Mail Preferences
Allow you to set to sent e-mail of the following events:
• Storage system information
• Storage system warnings
• Storage system errors
6-18 Chapter 6: RAID conguration
This chapter provides instructions for
installing the necessary drivers for
different system components.
Chapter 7
Driver installation
7-2 Chapter 7: Driver installation
7.1 RAID driver installation
After creating the RAID sets for your server system, you are now ready to install
an operating system to the independent hard disk drive or bootable array. This part
provides the instructions on how to install the RAID controller drivers during OS
installation.
7.1.1 Creating a RAID driver disk
The system does not include a oppy drive. You have to use a USB oppy drive
when creating a SATA RAID driver disk.
If you have created RAID sets with the LSI Software RAID conguration utility,
the boot priority of the SATA optical disk drive has to be manually adjusted.
Otherwise, the system will not boot from the connected SATA ODD.
A oppy disk with the RAID driver is required when installing Windows® or Red Hat
® Enterprise operating system on a hard disk drive that is included in a RAID set.
You can create a RAID driver disk in DOS (using the Makedisk application in the
support DVD).
To create a RAID driver disk in DOS environment:
1. Place the motherboard support DVD in the optical drive.
2. Restart the computer.
3. Enter the BIOS Setup.
4. Select the optical drive as the rst boot priority to boot from the support DVD.
Save your changes.
5. Exit the BIOS Setup and restart the computer.
The following Makedisk menu appears.
6. Select the C22x INTEL RAID Driver and press <Enter> to go to the sub-
menu.
7. From the Makedisk sub-menu, use the Up or Down arrow keys to select the
driver and press <Enter> to create the RAID driver disk.
Create Driver Diskette Menu
C22x INTEL RAID Driver
Write DMI
FreeDOS command prompt
C22x INTEL RAID Driver
Windows 32 bit(AHCI / AHCI RAID)
Windows Server 2012 64 bit (AHCI / AHCI RAID)
Back
Exit
ASUS RS300-E8 Series 7-3
8. Select YES from the following warning message then press <Enter>.
WARNING !!!
NO YES
)DO YOU WANT TO CONTINUE ?
ALL DATA ON THE FLOPPY DISKETTE WILL BE
9. On the following Important message, select YES if an ASMB7 is installed,
otherwise select NO, then press <Enter>.
NO YES
YES
<Important>
Please ensure ASMB7-iKVM is well installed
on the motherboard.
10. Insert the formatted diskette into the disk drive and press <Enter>. The system
writes the image to the disk.
11. Press any key to continue when prompted.
The Create Driver Diskette Menu appears after the creation of the diskette is
nished.
To create a RAID driver disk in Windows® environment:
1. Start Windows®.
2. Place the motherboard support DVD into the optical drive.
3. Go to the Make disk menu, then select the type of RAID driver disk you want
to create.
4. Insert a oppy disk into the USB oppy disk drive.
5. Follow succeeding screen instructions to complete the process.
Write-protect the oppy disk to avoid computer virus infection.
7-4 Chapter 7: Driver installation
7.1.2 Installing the RAID controller driver
During Windows® Server 2008 OS installation
To install the RAID controller driver when installing Windows® Server 2008 OS
1. Boot the computer using the Windows® Server 2008 OS installation disc. Follow
the screen instructions to start installing Windows Server 2008.
3. Click Load Driver.
ASUS RS300-E8 Series 7-5
4. A message appears, reminding you to insert the installation media containing the
driver of the RAID controller driver. If you have only one optical drive installed
in your system, eject the Windows OS installation disc and replace with the
motherboard Support DVD into the optical drive. Click Browse to continue.
5. Locate the driver in the corresponding folder of the Support DVD, and then click
OK to continue.
6. Select the RAID controller driver you need from the list and click Next.
7. When the system nishes loading the RAID driver, replace the motherboard
Support DVD with the Windows Server installation disc. Select the drive to install
Windows and click Next.
8. Setup then proceeds with the OS installation. Follow screen instructions to
continue.
7-6 Chapter 7: Driver installation
7.2 Management applications and utilities
installation
When you place the support DVD into the optical drive, the DVD automatically displays
the main screen if Autorun is enabled in your computer. By default, the Drivers tab
is displayed.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
7.3 Running the Support DVD
1. The contents of the support DVD are subject to change at any time without
notice. Visit the ASUS website (www.asus.com) for the latest updates on
software and utilities.
2. The support DVD is supported on Windows® Server 2008 R2 and
Windows® Server 2012.
The support DVD that is bundled with your motherboard contains drivers,
management applications, and utilities that you can install to maximize the
features of your motherboard.
The main screen of the Support DVD contains the following tabs:
1. Drivers
2. Utilities
3. MakeDisk
4. Manual
5. Contact
The main screen of the Support DVD looks exactly the same on the Windows®
Server 2008 R2 and on the Windows® Server 2012 Operating System (OS).
ASUS RS300-E8 Series 7-7
The Drivers Menu shows the available device drivers if the system detects installed
devices. Install the necessary drivers to activate the devices.
7.3.2 Utilities menu tab
The Utilities menu displays the software applications and utilities that the motherboard
supports.
7.3.1 Drivers menu tab
7-8 Chapter 7: Driver installation
The MakeDisk menu contains items to create the Intel RAID driver disks.
7.3.3 MakeDisk menu tab
You have to press the arrow down button in the lower part of the screen to view
the remaining items of the MakeDisk menu.
7.3.4 Manual menu
The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter
user guide.
You need an internet browser installed in your OS to view the User Guide.
ASUS RS300-E8 Series 7-9
7.3.5 Contact information menu
The Contact menu displays the ASUS contact information, e-mail addresses,
and useful links if you need more information or technical support for your
7.3.6 Installing the Intel® Chipset device Software driver
4. Click Intel® Chipset Device Software from the Drivers menu to start the
installation.
This section provides the instructions on how to install the Intel® chipset device
software on the system.
You need to manually install the Intel® chipset device software on a Windows®
Operating System.
To install the Intel® chipset device software on Windows® Server 2008 R2:
1. Restart the computer.
2. Log with Administrator privileges.
3. Insert the Motherboard Support DVD to the optical drive.
The support DVD automatically displays the Drivers menu if Autorun is enabled
in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD
to locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.
EXE to run the support DVD.
7-10 Chapter 7: Driver installation
5. From the Intel® Chipset Device
Software, click Next to start the
installation.
6. In the License Agreement
window, click Yes to continue.
7. Read the Readme File information
and click Next to continue.
ASUS RS300-E8 Series 7-11
9. When the installation of les is nish,
click Next.
10. When prompted to restart the
computer, select Yes, I want
to restart this computer now
then click Finish to complete the
installation.
8. Click Install in the Windows Security
window.
The Windows Security window may appear more than once and you may have to
click Install several times to continue with the installation.
7-12 Chapter 7: Driver installation
4. Click Intel® Chipset Device Software from the Drivers menu to start the
installation.
To install the Intel® Chipset device software on Windows® Server 2012:
1. Restart the computer.
2. Log with Administrator privileges.
3. Insert the Motherboard Support DVD to the optical drive.
The support DVD automatically displays the Drivers menu if Autorun is enabled
in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
5. From the Intel® Chipset Device
Software, click Next.
6. In the License Agreement
window, click Yes to continue the
process.
ASUS RS300-E8 Series 7-13
7. Read the Readme File information
and click Next to continue.
8. When the loading fo les is nish,
click Finish to complete the
installation.
7-14 Chapter 7: Driver installation
7.4 Installing the LAN driver
4. Click Intel® Network Connections
Software on the Drivers menu to
start the installation.
This section provides the instructions on how to install the Intel® Network Connections
Software drivers on the system.
You need to manually install the LAN controller driver on a Windows® operating
system.
To install the LAN controller device on Windows® Server 2008 R2:
1. Restart the computer.
2. Log with Administrator privileges.
3. Insert the Motherboard Support DVD to the optical drive.
The support DVD automatically displays the Drivers menu if Autorun is enabled
in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
5. From the Intel® Network
Connections window, click Install
Drivers and Software.
ASUS RS300-E8 Series 7-15
6. Click Next in the Welcome to the
InstallShield Wizard for Intel(R)
Network Connections.
7. Toggle I accept the terms in the
license agreement then click Next in
the License Agreement window.
8. Select the drivers you want to install in
the Setup Options window and click
Next.
9. From the Ready to Install the
Program window, click Install.
7-16 Chapter 7: Driver installation
11. When the loading of drivers is
nish, click Finish to complete the
installation.
10. Click Yes when the Microsoft
Management Console dialog box
appears.
The Microsoft Management
Console dialog box appears
when the system detects open
or running applications that
needs to be closed. You have
to terminate open or running
applications specied in the
dialog box to proceed with the
installation.
4. Click Intel® Network Connections Software on the Drivers menu to start
the installation.
To install the LAN controller device on Windows® Server 2012:
1. Restart the computer.
2. Log with Administrator privileges.
3. Insert the Motherboard Support DVD to the optical drive.
The support DVD automatically displays the Drivers menu if Autorun is enabled
in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
ASUS RS300-E8 Series 7-17
5. From the Intel® Network
Connections window, click Install
Drivers and Software.
6. Click Next in the Welcome to the
InstallShield Wizard for Intel(R)
Network Connections window.
7. Select the drivers you want to install
in the Setup Options window and
click Next.
7-18 Chapter 7: Driver installation
8. Click Install to continue.
9. When the the installation of les is
nish, click Finish to complete the
installation.
ASUS RS300-E8 Series 7-19
7.5 Installing the VGA driver
This section provides the instructions on how to install the ASPEED Video
Graphics Adapter (VGA) driver.
You need to manually install the ASPEED Video Graphics Adapter (VGA) driver
on a Windows® operating system.
To install the ASPEED VGA driver on Windows® Server 2008 R2:
1. Restart the computer.
2. Log with Administrator privileges.
3. Insert the Motherboard Support DVD to the optical drive.
The support DVD automatically displays the Drivers menu if Autorun is enabled
in your computer.
The Main menu of the Support
DVD appears.
4. Click ASPEED AST2300/AST1300
Display Driver on the Drivers
menu to start the installation.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
5. Toggle I accept the terms in the
license agreement and click Next in
the License Agreement window.
7-20 Chapter 7: Driver installation
6. Enter a username and
organization then click Next.
7. Toggle Complete in the Setup
Type window then click Next.
8. Click Install to begin the
installation.
9. When the the installation of les is
complete, click Finish.
ASUS RS300-E8 Series 7-21
10. When prompted to restart the
computer, click Yes.
To install the ASPEED VGA driver on Windows® Server 2012:
1. Restart the computer.
2. Log with Administrator privileges.
3. Insert the Motherboard Support DVD to the optical drive.
The support DVD automatically displays the Drivers menu if Autorun is enabled
in your computer.
4. Click ASPEED AST2300/AST1300 Display Driver on the Drivers menu to
start the installation.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
5. Click OK in the Driver Information
window.
Wait for the loading of drivers to nish.
6. Click OK to complete the installation.
7-22 Chapter 7: Driver installation
7.6 Installing the Intel® C22x MEI NULL HECI
This section provides the instructions on how to install the Intel® C22x MEI NULL
HECI driver on the motherboard.
To install the Intel® C22x MEI NULL HECI driver in Windows:
1. Restart the computer.
2. Log on with Administrator privileges.
3. Insert the motherboard/system support DVD to the optical drive.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
4. Click Intel® C22x MEI NULL HECI on
the Drivers menu of the main screen
to start the installation.
5. The Welcome to the Setup
Program window appears. Click
Next.
ASUS RS300-E8 Series 7-23
6. Click Yes in the License Agreement
window to continue with the
installation.
7. Click NEXT when the installation
of driver is complete.
9. Click Finish to complete the
installation.
7-24 Chapter 7: Driver installation
7.7 Installing the Intel® I210 Gigabit
This section provides the instructions on how to install the Intel® I210 Gigabit
Adapter driver on the system.
To install the Intel® I210 Gigabit Adapter driver on Windows® Server 2008 R2:
1. Restart the computer.
2. Log on with Administrator privileges.
3. Insert the motherboard/system support DVD to the optical drive.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
4. Click Intel® I210 Gigabit Adapter
Driver in the Drivers menu of the
main screen to start the installation.
5. Click Next to continue.
6. Toggle Modify then click Next in the
Program Maintenance window.
ASUS RS300-E8 Series 7-25
8. Click Install in the Ready to Modify
the Program window to begin with the
loading of the selected options.
7. Select the options you want to install
then click Next to continue.
9. When the the installation of les is
complete, click Finish.
7-26 Chapter 7: Driver installation
To install the Intel® I210 Gigabit Adapter driver on Windows® Server 2012:
1. Restart the computer.
2. Log on with Administrator privileges.
3. Insert the motherboard/system support DVD to the optical drive.
If Autorun is NOT enabled in your computer, browse the contents of the support
DVD to locate the le ASSETUP.EXE from the BIN folder. Double-click the
ASSETUP.EXE to run the support DVD.
4. Click Intel® I210 Gigabit Adapter Driver in the Drivers menu of the main
screen to start the installation.
5. Click Next to continue.
6. Toggle Modify then click Next in the
Program Maintenance window.
7. Select the options you want to install
then click Next to continue.
ASUS RS300-E8 Series 7-27
8. In the Ready to Modify the Program
window, click Install to load the
options you selected.
9. When the the installation of les is
complete, click Finish.
7-28 Chapter 7: Driver installation
ASUS RS300-E8 Series A-1
ASUS contact information
ASUSTeK COMPUTER INC.
Address 15 Li-Te Road, Peitou, Taipei, Taiwan 11259
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
E-mail info@asus.com.tw
Web site http://www.asus.com.tw
Technical Support
Telephone +86-21-38429911
Fax +86-21-58668722 ext: 9101
Online Support http://support.asus.com/techserv/techserv.aspx
ASUSTeK COMPUTER INC. (Taiwan)
Address 15 Li-Te Road, Peitou, Taipei, Taiwan 11259
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
E-mail info@asus.com.tw
Web site http://www.asus.com.tw
Technical Support
Telephone +886-2-2894-3447 (0800-093-456)
Online Support http://support.asus.com/techserv/techserv.aspx
ASUSTeK COMPUTER INC. (China)
Address No.508, Chundong Road, Xinzhuang Industrial Zone,
Minhang District, Shanghai, China.
Telephone +86-21-5442-1616
Fax +86-21-5442-0099
Web site http://www.asus.com.cn
Technical Support
Telephone +86-21-3407-4610 (800-820-6655)
Online Support http://support.asus.com/techserv/techserv.aspx
ASUS contact information
ASUS COMPUTER INTERNATIONAL (America)
Address 800 Corporate Way, Fremont, CA 94539, USA
Fax +1-510-608-4555
Web site http://usa.asus.com
Technical Support
Support fax +1-812-284-0883
General support +1-812-282-2787
Online support http://support.asus.com/techserv/techserv.aspx
ASUS COMPUTER GmbH (Germany and Austria)
Address Harkort Str. 21-23, D-40880 Ratingen, Germany
Fax +49-2102-959911
Web site http://www.asus.de
Online contact http://www.asus.de/sales
Technical Support
Telephone +49-1805-010923
Support Fax +49-2102-959911
Online support http://support.asus.com/techserv/techserv.aspx
ASUS Czech Service s.r.o. (Europe)
Address Na Rovince 887, 720 00 Ostrava – Hrabová, Czech
Republic
Telephone +420-596766888
Web site http://www.asus.cz
Technical Support
Telephone +420-596-766-891
Fax +420-596-766-329
E-mail advance.rma.eu@asus.com
Online Support http://support.asus.com/techserv/techserv.aspx
ASUS RS300-E8 Series A-3
ASUS contact information
ASUS Holland BV (The Netherlands)
Address Marconistraat 2, 7825GD EMMEN, The Netherlands
Web site http://www.asus.com
Technical Support
Telephone +31-(0)591-5-70292
Fax +31-(0)591-666853
E-mail advance.rma.eu@asus.com
Online Support http://support.asus.com/techserv/techserv.aspx
ASUS Polska Sp. z o.o. (Poland)
Address Ul. Postępu 6, 02-676 Warszawa, Poland
Web site http://pl.asus.com
Technical Support
Telephone +48-225718033
Online Support http://support.asus.com/techserv/techserv.aspx
ASK-Service (Russia and CIS)
Address г.Москва, ул. Орджоникидзе, д.10, Россия
Telephone (495) 640-32-75
Web site http://ru.asus.com
Technical Support
Telephone 008-800-100-ASUS (008-800-100-2787)
Online Support http://vip.asus.com/eservice/techserv.aspx?SLanguage=ru
A-4 Appendix