Table of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Hardware Information
- 2.1 Chassis cover
- 2.2 Air ducts
- 2.3 Central Processing Unit (CPU)
- 2.4 System memory
- 2.5 Storage devices
- 2.6 Expansion slot
- 2.6.1 Installing an expansion card to the PCIe riser card bracket
- 2.6.2 Installing an OCP 3.0 slot baseboard and OCP 3.0 card to the PCIe riser card bracket
- 2.6.3 Installing an expansion card to the butterfly riser card bracket
- 2.6.4 Installing an ethernet expansion card to the butterfly riser card bracket
- 2.6.5 Installing an ASUS PIKE II card
- 2.6.6 Installing an M.2 (NGFF) card
- 2.6.7 Configuring an expansion card
- 2.7 Cable connections
- 2.8 Backplane cabling
- 2.9 Storage device configuration and cabling
- 2.10 Removable/optional components
- Chapter 3: Installation Options
- Chapter 4: Motherboard Information
- Chapter 5: BIOS Setup
- 5.1 Managing and updating your BIOS
- 5.2 BIOS setup program
- 5.3 Main menu
- 5.4 Performance Tuning menu
- 5.5 Advanced menu
- 5.5.1 Trusted Computing
- 5.5.2 PSP Firmware Versions
- 5.5.3 APM Configuration
- 5.5.4 Onboard LAN Configuration
- 5.5.5 Serial Port Console Redirection
- 5.5.6 CPU Configuration
- 5.5.7 PCI Subsystem Settings
- 5.5.8 USB Configuration
- 5.5.9 Network Stack Configuration
- 5.5.10 CSM Configuration
- 5.5.11 NVMe Configuration
- 5.5.12 SATA Configuration
- 5.5.13 AMD Mem Configuration Status
- 5.5.14 iSCSI Configuration
- 5.6 Chipset menu
- 5.7 Security menu
- 5.8 Boot menu
- 5.9 Tool menu
- 5.10 Save & Exit menu
- 5.11 AMD CBS menu
- 5.12 Event Logs menu
- 5.13 Server Mgmt menu
- Chapter 6: Driver Installation
- Appendix
ASUS RS700A-E11-RS12U/10G/4NVME(1600W) User Manual
Displayed below is the user manual for RS700A-E11-RS12U/10G/4NVME(1600W) by ASUS which is a product in the Server Barebones category. This manual has pages.
Related Manuals
1U Rackmount Server
User Guide
RS700A-E11 Series
RS700A-E11-RS12U
ii
Copyright © 2021 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language in any form or by any means,
except documentation kept by the purchaser for backup purposes, without the express written permission
of ASUSTeK COMPUTER INC. (“ASUS”).
ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not
limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no
event shall ASUS, its directors, officers, employees, or agents be liable for any indirect, special, incidental,
or consequential damages (including damages for loss of profits, loss of business, loss of use or data,
interruption of business and the like), even if ASUS has been advised of the possibility of such damages
arising from any defect or error in this manual or product.
Specifications and information contained in this manual are furnished for informational use only, and are
subject to change at any time without notice, and should not be construed as a commitment by ASUS.
ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual,
including the products and software described in it.
Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless
such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identification or explanation and to the
owners’ benefit, without intent to infringe.
E18390
Revised Edition V2
April 2021
iii
Contents
Safety information ..................................................................................................... vii
About this guide ......................................................................................................... ix
Chapter 1: Product Introduction
1.1 System package contents ......................................................................... 1-2
1.2 Serial number label .................................................................................... 1-3
1.3 System specifications ...............................................................................1-4
1.4 Front panel features ...................................................................................1-7
1.5 Rear panel features ....................................................................................1-7
1.6 Internal features .........................................................................................1-8
1.7 LED information .........................................................................................1-9
1.7.1 Front panel LEDs ........................................................................ 1-9
1.7.2 Storage device status LED........................................................ 1-10
1.7.3 LAN (RJ-45) LEDs .................................................................... 1-11
1.7.4 Rear panel LEDs ....................................................................... 1-11
1.7.5 Q-Code table ............................................................................. 1-12
Chapter 2: Hardware Information
2.1 Chassis cover .............................................................................................2-2
2.1.1 Removing the rear cover ............................................................. 2-2
2.2 Air ducts......................................................................................................2-3
2.2.1 Removing the air ducts ............................................................... 2-3
2.2.2 Installing the air ducts ................................................................. 2-3
2.3 Central Processing Unit (CPU) .................................................................2-4
2.3.1 Installing the CPU and heatsink .................................................. 2-4
2.4 System memory .........................................................................................2-7
2.4.1 Overview ..................................................................................... 2-7
2.4.2 Memory Configurations ............................................................... 2-8
2.4.3 Installing a DIMM ........................................................................ 2-9
2.4.4 Removing a DIMM ...................................................................... 2-9
2.5 Storage devices........................................................................................2-10
2.5.1 To install a 2.5” hot-swap SATA/SAS/NVMe storage device: ... 2-10
2.6 Expansion slot ..........................................................................................2-12
2.6.1 Installing an expansion card to the PCIe riser card bracket ...... 2-12
2.6.2 Installing an OCP 3.0 slot baseboard and OCP 3.0 card to
the PCIe riser card bracket ....................................................... 2-17
2.6.3 Installing an expansion card to the butterfly riser card
bracket ...................................................................................... 2-19
iv
Contents
2.6.4 Installing an ethernet expansion card to the butterfly riser card
bracket ...................................................................................... 2-22
2.6.5 Installing an ASUS PIKE II card ................................................ 2-23
2.6.6 Installing an M.2 (NGFF) card ................................................... 2-26
2.6.7 Configuring an expansion card ................................................. 2-27
2.7 Cable connections ...................................................................................2-28
2.8 Backplane cabling ...................................................................................2-29
2.9 Storage device configuration and cabling ............................................2-30
2.9.1 12 x SATA storage device configuration and cabling ............... 2-31
2.9.2 4 x NVMe storage device configuration and cabling ................. 2-35
2.9.3 8 x NVMe storage device configuration and cabling ................. 2-39
2.9.4 12 x NVMe storage device configuration and cabling ............... 2-43
2.9.5 8 x SAS and 4 x SATA storage device configuration and
cabling ....................................................................................... 2-47
2.10 Removable/optional components ...........................................................2-52
2.10.1 System fans .............................................................................. 2-52
2.10.2 Redundant power supply module.............................................. 2-56
Chapter 3: Installation Options
3.1 Tool-less Friction Rail Kit ..........................................................................3-2
3.1.1 Installing the tool-less rack rail .................................................... 3-2
3.2 Rail kit dimensions ....................................................................................3-4
3.3 Cable management arm (optional for 1200 mm rack rails) ....................3-5
3.3.1 Attaching the cable management arm ........................................ 3-5
Chapter 4: Motherboard Information
4.1 Motherboard layout ....................................................................................4-2
4.2 Jumpers ......................................................................................................4-4
4.3 Internal LEDs .............................................................................................. 4-9
4.4 Internal connectors ..................................................................................4-11
Chapter 5: BIOS Setup
5.1 Managing and updating your BIOS ..........................................................5-2
5.1.1 ASUS CrashFree BIOS 3 utility................................................... 5-2
5.1.2 ASUS EZ Flash Utility ................................................................. 5-3
5.1.3 BUPDATER utility ....................................................................... 5-4
5.2 BIOS setup program ..................................................................................5-6
5.2.1 BIOS menu screen ...................................................................... 5-7
v
Contents
5.2.2 Menu bar ..................................................................................... 5-7
5.2.3 Menu items..................................................................................5-8
5.2.4 Submenu items ........................................................................... 5-8
5.2.5 Navigation keys ........................................................................... 5-8
5.2.6 General help................................................................................5-8
5.2.7 Configuration fields ..................................................................... 5-8
5.2.8 Pop-up window............................................................................5-8
5.2.9 Scroll bar ..................................................................................... 5-8
5.3 Main menu ..................................................................................................5-9
5.3.1 System Language [English] ........................................................ 5-9
5.3.2 System Date [Day xx/xx/xxxx] ..................................................... 5-9
5.3.3 System Time [xx:xx:xx] ............................................................... 5-9
5.4 Performance Tuning menu ......................................................................5-10
5.5 Advanced menu .......................................................................................5-11
5.5.1 Trusted Computing.................................................................... 5-12
5.5.2 PSP Firmware Versions ............................................................ 5-12
5.5.3 APM Configuration .................................................................... 5-12
5.5.4 Onboard LAN Configuration ...................................................... 5-13
5.5.5 Serial Port Console Redirection ................................................ 5-14
5.5.6 CPU Configuration .................................................................... 5-18
5.5.7 PCI Subsystem Settings ........................................................... 5-19
5.5.8 USB Configuration .................................................................... 5-20
5.5.9 Network Stack Configuration..................................................... 5-21
5.5.10 CSM Configuration .................................................................... 5-22
5.5.11 NVMe Configuration .................................................................. 5-23
5.5.12 SATA Configuration .................................................................. 5-24
5.5.13 AMD Mem Configuration Status................................................ 5-24
5.5.14 iSCSI Configuration...................................................................5-25
5.6 Chipset menu ...........................................................................................5-26
5.7 Security menu ..........................................................................................5-27
5.8 Boot menu ................................................................................................5-31
5.9 Tool menu ................................................................................................. 5-32
5.10 Save & Exit menu ..................................................................................... 5-33
5.11 AMD CBS menu ........................................................................................5-34
5.11.1 CPU Common Options.............................................................. 5-35
5.11.2 DF Common Options ................................................................ 5-38
5.11.3 UMC Common Option ............................................................... 5-40
vi
5.11.4 NBIO Common Options ............................................................ 5-50
5.11.5 NTB Common Options .............................................................. 5-54
5.12 Event Logs menu .....................................................................................5-55
5.12.1 Change Smbios Event Log Settings ......................................... 5-55
5.12.2 View Smbios Event Log ............................................................ 5-56
5.13 Server Mgmt menu ...................................................................................5-57
Chapter 6: Driver Installation
6.1 Running the Support DVD .........................................................................6-2
Appendix
KMPP-D32 block diagram ....................................................................................... A-2
Notices .................................................................................................................... A-3
ASUS contact information ...................................................................................... A-6
Contents
vii
Safety information
Electrical Safety
• Before installing or removing signal cables, ensure that the power cables for the system
unit and all attached devices are unplugged.
• To prevent electrical shock hazard, disconnect the power cable from the electrical outlet
before relocating the system.
• When adding or removing any additional devices to or from the system, ensure that the
power cables for the devices are unplugged before the signal cables are connected. If
possible, disconnect all power cables from the existing system before you add a device.
• If the power supply is broken, do not try to fix it by yourself. Contact a qualified service
technician or your dealer.
Operation Safety
• Any mechanical operation on this server must be conducted by certified or experienced
engineers.
• Before operating the server, carefully read all the manuals included with the server
package.
• Before using the server, ensure all cables are correctly connected and the power cables
are not damaged. If any damage is detected, contact your dealer as soon as possible.
• To avoid short circuits, keep paper clips, screws, and staples away from connectors,
slots, sockets and circuitry.
• Avoid dust, humidity, and temperature extremes. Place the server on a stable surface.
• If you encounter technical problems with the product, contact a qualified service
technician or your retailer.
This product is equipped with a three-wire power cable and plug for the user’s safety. Use
the power cable with a properly grounded electrical outlet to avoid electrical shock.
viii
Heavy System
CAUTION! This server system is heavy. Ask for assistance when moving
or carrying the system.
Lithium-Ion Battery Warning
CAUTION! Danger of explosion if battery is incorrectly replaced. Replace
only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
To prevent exposure to the optical drive’s laser, do not attempt to disassemble or repair the
optical drive by yourself. For your safety, contact a professional technician for assistance.
CLASS 1 LASER PRODUCT
Optical Drive Safety Information
Laser Safety Information
ix
About this guide
Audience
This user guide is intended for system integrators, and experienced users with at least basic
knowledge of configuring a server.
Contents
This guide contains the following parts:
1. Chapter 1: Product Introduction
This chapter describes the general features of the server, including sections on front
panel and rear panel specifications.
2. Chapter 2: Hardware Information
This chapter lists the hardware setup procedures that you have to perform when
installing or removing system components.
3. Chapter 3: Installation Options
This chapter describes how to install optional components into the barebone server.
4. Chapter 4: Motherboard Information
This chapter gives information about the motherboard that comes with the server. This
chapter includes the motherboard layout, jumper settings, and connector locations.
5. Chapter 5: BIOS Setup
This chapter tells how to change system settings through the BIOS Setup menus and
describes the BIOS parameters.
6. Chapter 6: Driver Installation
This chapter provides instructions for installing the necessary drivers for different
system components.
x
References
Refer to the following sources for additional information, and for product and software
updates.
1. ASUS Control Center (ACC) user guide
This manual tells how to set up and use the proprietary ASUS server management
utility. Visit asuscontrolcenter.asus.com for more information.
2. ASUS websites
The ASUS websites worldwide provide updated information for all ASUS hardware and
software products. Refer to the ASUS contact information.
Conventions
To ensure that you perform certain tasks properly, take note of the following symbols used
throughout this manual.
Typography
Bold text Indicates a menu or an item to select.
Italics
Used to emphasize a word or a phrase.
<Key> Keys enclosed in the less-than and greater-than sign
means that you must press the enclosed key.
Example: <Enter> means that you must press the Enter
or Return key.
<Key1>+<Key2>+<Key3> If you must press two or more keys simultaneously, the
key names are linked with a plus sign (+).
Example: <Ctrl>+<Alt>+<Del>
Command Means that you must type the command exactly as
shown, then supply the required item or value enclosed in
brackets.
Example: At the DOS prompt, type the command line:
format A:/S
DANGER/WARNING: Information to prevent injury to yourself when trying to
complete a task.
CAUTION: Information to prevent damage to the components when
trying to complete a task.
IMPORTANT: Instructions that you MUST follow to complete a task.
NOTE: Tips and additional information to help you complete a task.
This chapter describes the general features of the chassis kit. It
includes sections on front panel and rear panel specifications.
1
Product Introduction
Chapter 1: Product Introduction
Chapter 1: Product Introduction
1-2
If any of the above items is damaged or missing, contact your retailer.
1.1 System package contents
Check your system package for the following items.
Model Name RS700A-E11-RS12U
Chassis ASUS R12F 1U Rackmount Chassis
Motherboard ASUS KMPP-D32 Server Board
Component
1 x 1200W 80PLUS Platinum Power Supply or 1600W 80PLUS Platinum Power
Supply
1 x 2.5-inch Storage Device Backplane
12 x 2.5-inch Storage Device Trays or Dummy Trays
1 x Front Panel Board
2 x Riser Card
8 x System Fans (40 mm x 40 mm x 56 mm)
Accessories
1 x AMD EPYC™ Support DVD
1 x Bag of Screws
2 x CPU Heatsink
2 x AC Power Cable
Optional Items
1 x 1200W 80PLUS Platinum Power Supply or 1600W 80PLUS Platinum Power
Supply (Second PSU)
1 x Friction Rail Kit
ASUS RS700A-E11 Series 1-3
1.2 Serial number label
The product’s serial number contains 12 characters such as xxS0xxxxxxxx and printed on the
sticker at the server's front cover.
The correct serial number of the product is required if you need to request for support from
the ASUS Technical Support team.
xxS0xxxxxxxx
RS700A-E11-RS12U
Chapter 1: Product Introduction
1-4
1.3 System specifications
The ASUS RS700A-E11 Series features the ASUS KMPP-D32 server board. The server
supports AMD EPYC™ 7002/7003 Series processors plus other latest technologies through
the chipsets onboard.
(continued on the next page)
Model Name RS700A-E11-RS12U
Motherboard KMPP-D32
Processor Support
2 x Socket SP3 (LGA 4094)
AMD EPYC™ 7002/7003 Series
xGMI (External Global Memory Interface Link)
Core Logic System on Chip (SoC)
Memory
Total Slots 32 (8-channel per CPU, 16 DIMM per CPU)
Capacity Maximum up to 4096GB
Memory Type DDR4 3200/2933 RDIMM/ LRDIMM/ 3DS LRDIMM
* Please refer to www.asus.com for latest momory AVL update
Memory Size
64GB, 32GB, 16GB RDIMM
64GB, 128GB LRDIMM
64GB, 128GB, 256GB LRDIMM 3DS / 3DS RDIMM
* Refer to www.asus.com/support for more information
Expansion
Slots
Total PCI/PCIe/PIKE
Slots 3 x Expansion slots + 1 x Internal PIKE slot
Slot Type
Up to 3 PCIe Gen4 slots
1 x PCI-E x16 (Gen4 x16 link), FH, FL (CPU1)
1 x PCI-E x16 (Gen4 x16 link), FH, FL or OCP3.0 (CPU2)
1 x PCIe Gen4 x8 or x16, LPHL (if PCIe M.2 is in use, it will
operate at x8 link) (CPU2)
M.2 2 x M.2 (Up to 22110) (CPU2) (Supports SATA / PCIe M.2)
Micro SD Card slot 1
Proprietary Slot 1 1 x PCIe Gen4 x8 (for pike card only)
Proprietary Slot 2 4 x 1Gb RJ45 Lan Module Card or
2 x 10Gb RJ45 Lan Module Card
Disk
Controller
SATA Controller 12 x SATA 6Gb/s ports
2 x M.2 connectors (SATA 6Gb/s & PCIe Gen4 x4 link)
SAS Controller
Optional kits:
ASUS PIKE II 3008 8-port SAS 12Gb/s HBA card
ASUS PIKE II 3108 8-port SAS HW 12Gb/s RAID card
Broadcom MegaRAID 9560-16i card
Storage
Bays
Storage Bay
12 x 2.5” Hot-Swap Drive Bays (12 x SATA/SAS, optional
NVMe)
* SAS support only from optional SAS HBA/RAID card
* Support tri-mode card (only for storage bays 9 - 12)
Motherboard
onboard connectors
2 x M.2 connectors
2 x miniSAS HD connector
ASUS RS700A-E11 Series 1-5
Model Name RS700A-E11-RS12U
Storage
Bays
Default Cable
2 x SLIMILINE SAS to SLIMLINE SAS Cable
1 x SLIMLINE SAS to MINI SAS HD Cable
2 x MINI SAS HD to MINI SAS HD Cable
NVMe upgrade
option
Supports 4 x NVMe: via 2 x NVMe cable
Support 8 x NVMe: via 4 x NVMe cable
* Please refer to Asus server Upgrade Part List for the latest update
Networking
1 x Quad port Intel® I350-AM4 1G LAN controller
or
1 x Dual port Intel® X710-AT2 Gigabit 10G LAN controller
1 x Management Port
Optional OCP Adapter:
Up to 100Gb/s Ethernet / InfiniBand Adapter
VGA Aspeed AST2600 64MB
Graphic Up to 2 single slot GPU support or 1 dual slot GPU support
Front I/O Ports -
Rear I/O Ports
2 x USB 3.2 Gen1 ports
1 x VGA port
1 x RJ-45 Mgmt LAN port
1 x OCP 3.0 port
Optional
2 x 10G RJ-45 GbE LAN ports
or
4 x 1G RJ-45 GbE LAN ports
Switch/LED
Front Switch/LED:
1 x Power Switch (w/ LED)
1 x Reset Switch
1 x Location Switch (w/ LED)
1 x HDD Access LED*
1 x Message LED
LAN 1-4 LED (on NIC module)**
* The HDD Access LED is only functional when an ASUS PIKE II
card is installed and connected.
** The number of LAN LEDs available depends on the LAN
Controller card installed.
Rear Switch/LED:
1 x Port 80 LED (Q-Code)
1 x Power Switch w/ LED
1 x Location Switch w/ LED
1 x Message LED
Security Options TPM-SPI
PFR
(continued on the next page)
Chapter 1: Product Introduction
1-6
*Specifications are subject to change without notice.
Model Name RS700A-E11-RS12U
OS Support
Windows® Server 2019
RedHat® Enterprise Linux
SuSE® Linux Enterprise Server
CentOS
Ubuntu
VMware
* Please find the latest OS support from https://www.asus.com/
Management
Solution
Software ASUS Control Center
Out of Band
Remote
Management
On-Board ASMB10-iKVM for KVM-over-IP
Regulatory Compliance BSMI, CE, C-Tick, FCC(Class A)
Dimension 842.5mm x 449mm x 43.85mm (1U)
Net Weight Kg (CPU, DRAM &
HDD not included) 18.85 Kg
Gross Weight Kg (CPU, DRAM
& HDD not included, Packing
include)
23.89 Kg
Power Supply
(different configuration by region)
1+1 Redundant 1200W or 1600W 80 PLUS Platinum Power
Supply
Rating: 100-127/200-240Vac,9.4A/4.72A (x2) ,50/60Hz Class I
(240Vdc, 4.6A Only for China)
Environment
Operation temperature: 10° ~ 35°
Non operation temperature: -40° ~ 60°
Non operation humidity: 20% ~ 90% (Non condensing)
ASUS RS700A-E11 Series 1-7
1.4 Front panel features
The barebone server displays a simple yet stylish front panel with easily accessible features.
The power and reset buttons, LED indicators are located on the front panel.
Refer to section 1.7 LED information for the LED descriptions.
• Bay 1 to bay 8 supports NVMe/SATA by default. SAS support requires optional ASUS
PIKE II card.
• Bay 9 to bay 12 supports NVMe/SATA by default (supports tri-mode card).
• All bays support 2.5” drives with trays.
Asset tag
Rack screw
Rack screw
Power LED
LAN1 and LAN3 LED
LAN2 and LAN4 LED
Location LED
Message LED
Power button Reset button
Location button
Bay 1 Bay 3 Bay 5 Bay 7 Bay 9
Bay 10
Bay 11
Bay 12
Bay 2 Bay 4 Bay 6 Bay 8
*This port is for ASUS ASMB10-iKVM only.
1.5 Rear panel features
The rear panel includes the expansion slots, and system power sockets. The middle part
includes the I/O shield with openings for the rear panel connectors on the motherboard.
Q-Code LED
Expansion slot
Expansion slot
Expansion slot Optional
External
Fan location
(for GPU)
Power button
VGA port
Location button
Redundant Power supply and
Power cord connector
USB 3.2 Gen 1 ports
Optional LAN port
expansion slots
Management LAN port 1*
Chapter 1: Product Introduction
1-8
1.6 Internal features
The barebone server includes the basic components as shown.
The barebone server does not include a floppy disk drive. Connect a USB floppy disk drive
to any of the USB ports on the front or rear panel if you need to use a floppy disk.
WARNING
HAZARDOUS MOVING PARTS
KEEP FINGERS AND OTHER BODY PARTS AWAY
A protection film is pre-attached to the front cover before shipping. Please remove the
protection film before turning on the system for proper heat dissipation.
1. Redundant Power supply
2. ASUS KMPP-D32 Server
Board
3. ASUS PIKE II card
4. System fans
5. 12 x 2.5“ storage device
trays
6. SATA/SAS backplane
(hidden)
7. PCIe riser card (hidden)
8. Butterfly riser card
(Gen4 x16 link)
9. Asset tag (hidden)
10. External Fan (optional, for
GPU)
ASUS RS700A-E11 Series 1-9
1.7 LED information
1.7.1 Front panel LEDs
LED Display status Description
Power LED ON System power ON
Message LED OFF
ON
System is normal; no incoming event
A hardware monitor event is indicated
Location LED
OFF
ON
Normal status
Location switch is pressed
(Press the location switch again to turn off)
LAN LEDs
OFF
Blinking
ON
No LAN connection
LAN is transmitting or receiving data
LAN connection is present
Power LED
LAN1 and LAN3 LED
LAN2 and LAN4 LED Location LED
Power button
Location button
Message LED
Reset button
Chapter 1: Product Introduction
1-10
1.7.2 Storage device status LED
SATA/SAS Storage Device LED Description
GREEN ON SATA/SAS storage device power ON
RED ON Storage device has failed and should be swapped immediately
(For RAID card)
GREEN/
RED Blinking RAID rebuilding (For RAID card)
GREEN/
RED Blinking Locate (For RAID card)
GREEN/
RED OFF Storage device not found
GREEN Blinking Read/write data from/into the SATA/SAS storage device
Red LED Green LED
ASUS RS700A-E11 Series 1-11
1.7.4 Rear panel LEDs
Q-Code LED
1.7.3 LAN (RJ-45) LEDs
ACT/LINK LED SPEED LED
Status Description Status Description
OFF No link OFF 10 Mbps connection
GREEN Linked ORANGE 100 Mbps connection
BLINKING Data activity GREEN 1 Gbps connection
ACT/LINK LED SPEED LED
Status Description Status Description
OFF No link OFF 10 Mbps / 100 Mbps connection
GREEN Linked ORANGE 1 Gbps connection
BLINKING Data activity GREEN 10 Gbps connection
ACT/LINK LED
ACT/LINK LED
SPEED LED
SPEED LED
Intel® I350-AM4 1G LAN port LEDs
Intel® X710-AT2 Gigabit 10G LAN port LEDs
Chapter 1: Product Introduction
1-12
1.7.5 Q-Code table
Action PHASE POST CODE TYPE DESCRIPTION
SEC Start up Security Phase
0x01 Progress First post code
0x02 Progress Load BSP microcode
0x03 Progress Perform early platform Initialization
0x04 Progress Set cache as ram for PEI phase
0x05 Progress Establish Stack
0x06 Progress CPU Early Initialization
PSP Boot
PSP Boot Loader
phase (Error Post
Codes)
0x00 Error General - Success
0x01 Error Generic Error Code
0x02 Error Generic Memory Error
0x03 Error Buffer Overflow
0x04 Error Invalid Parameter(s)
0x05 Error Invalid Data Length
0x06 Error Data Alignment Error
0x07 Error Null Pointer Error
0x08 Error Unsupported Function
0x09 Error Invalid Service ID
0x0A Error Invalid Address
0x0B Error Out of Resource Error
0x0C Error Timeout
0x0D Error data abort exception
0x0E Error prefetch abort exception
0x0F Error Out of Boundary Condition Reached
0x10 Error Data corruption
0x11 Error Invalid command
0x12 Error The package type provided by BR is incorrect
0x13 Error Failed to retrieve FW header during FW validation
0x14 Error Key size not supported
0x15 Error Agesa0 verification error
0x16 Error SMU FW verification error
0x17 Error OEM SINGING KEY verification error
0x18 Error Generic FW Validation error
0x19 Error RSA operation fail - bootloader
0x1A Error CCP Passthrough operation failed - internal status
0x1B Error AES operation fail
0x1C Error CCP state save failed
0x1D Error CCP state restore failed
0x1E Error SHA256 operation fail - internal status
0x1F Error ZLib Decompression operation fail
0x20 Error HMAC-SHA256 operation fail - internal status
0x21 Error Booted from boot source not recognized by PSP
0x22 Error PSP directory entry not found
0x23 Error PSP failed to set the write enable latch
0x24 Error PSP timed out because spirom took too long
0x25 Error Cannot find BIOS directory
0x26 Error SpiRom is not valid
0x27 Error slave die has different security state from master
0x28 Error SMI interface init failure
0x29 Error SMI interface generic error
0x2A Error invalid die ID executes MCM related function
0x2B Error invalid MCM configuration table read from bootrom
0x2C Error Valid boot mode wasn't detected
0x2D Error NVStorage init failure
0x2E Error NVStorage generic error
0x2F Error MCM 'error' to indicate slave has more data to send
0x30 Error MCM error if data size exceeds 32B
0x31 Error Invalid client id for SVC MCM call
0x32 Error MCM slave status register contains bad bits
0x33 Error MCM call was made in a single die environment
0x34 Error PSP secure mapped to invalid segment (should be 0x400_0000)
0x35 Error No physical x86 cores were found on die
0x36 Error Insufficient space for secure OS (range of free SRAM to SVC stack base)
0x37 Error SYSHUB mapping memory target type is not supported
0x38 Error Attempt to unmap permanently mapped TLB to PSP secure region
(continued on the next page)
AMD EPYC™ 7002 Series processors
ASUS RS700A-E11 Series 1-13
Action PHASE POST CODE TYPE DESCRIPTION
PSP Boot
PSP Boot Loader
phase (Error Post
Codes)
0x39 Error Unable to map an SMN address to AXI space
0x3A Error Unable to map a SYSHUB address to AXI space
0x3B Error The count of CCXs or cores provided by bootrom is not consistent
0x3C Error Uncompressed image size doesn't match value in compressed header
0x3D Error Compressed option used in case where not supported
0x3E Error Fuse info on all dies don't match
0x3F Error PSP sent message to SMU; SMU reported an error
0x40 Error Function RunPostX86ReleaseUnitTests failed in memcmp()
0x41 Error Interface between PSP to SMU not available.
0x42 Error Timer wait parameter too large
0x43 Error Test harness module reported an error
0x44 Error x86 wrote C2PMSG_0 interrupting PSP
0x45 Error A write to an L3 register failed
0x46 Error Mini-BL
0x47 Error Mini-BL CCP HMAC Unit-test failed
0x48 Error Potential stack corruption in jump to Mini BL
0x49 Error Error in Validate and Loading AGESA APOB SVC call
0x4A Error Correct fuse bits for DIAG_BL loading not set
0x4B Error The UmcProgramKeys() function was not called by AGESA
0x4C Error Secure unlock error
0x4D Error Syshub register programming mismatch during readback
0x4E Error Family ID in MP0_SFUSE_SEC[7:3] not correct
0x4F Error An operation was invoked that can only be performed by the GM
0x50 Error Failed to acquire host controller semaphore to claim ownership of SMB
0x51 Error Timed out waiting for host to complete pending transactions
0x52 Error Timed out waiting for slave to complete pending transactions
0x53 Error Unable to kill current transaction on host
0x54 Error One of: Illegal command
0x55 Error An SMBus transaction collision detected
0x56 Error Transaction failed to be started or processed by host
0x57 Error An unsolicited SMBus interrupt was received
0x58 Error An attempt to send an unsupported PSP-SMU message was made
0x59 Error An error/data corruption detected on response from SMU for sent msg
0x5A Error MCM Steady-state unit test failed
0x5B Error S3 Enter failed
0x5C Error AGESA BL did not set PSP SMU reserved addresses via SVC call
0x5E Error CcxSecBisiEn not set in fuse RAM
0x5F Error Received an unexpected result
0x60 Error VMG Storage Init failed
0x61 Error Failure in mbedTLS user app
0x62 Error An error occured whilst attempting to SMN map a fuse register
0x63 Error Fuse burn sequence/operation failed due to internal SOC error
0x64 Error Fuse sense operation timed out
0x65 Error Fuse burn sequence/operation timed out waiting for burn done
0x66 Error Failure status indicating that the given SecureOS has been
0x67 Error This PSP FW was revoked
0x68 Error The platform model/vendor id fuse is not matching the BIOS public key
token
0x69 Error The BIOS OEM public key of the BIOS was revoked for this platform
0x6A Error PSP level 2 directory not match expected value.
0x6B Error BIOS level 2 directory not match expected value.
0x6C Error HVB validation failure for BIOS RTM volume (OEM public/signature failed
to validate).
0x6D Error Generic error indicating the CCP HAL initialization failed
0x94 Error Knoll failed to idle correctly after being reset
0x95 Error Bad status returned by I2CKnollCheck
0x96 Error NACK to general call (no device on Knoll I2C bus)
0x97 Error Null pointer passed to I2CKnollCheck
0x98 Error Invalid device-ID found during Knoll authentication
0x99 Error Error during Knoll/Prom key derivation
0x9A Error Null pointer passed to Crypto function
0x9B Error Error in checksum from wrapped Knoll/Prom keys
0x9C Error Knoll returned an invalid response to a command
0x9D Error Bootloader failed in Knoll Send Command function
0x9E Error No Knoll device found by verifying MAC
(continued on the next page)
Chapter 1: Product Introduction
1-14
Action PHASE POST CODE TYPE DESCRIPTION
PSP Boot
PSP Boot Loader
phase (Status Post
Codes)
0xA0 Progress Bootloader successfully entered C Main
0xA1 Progress Master initialized C2P / slave waited for master to init C2P
0xA2 Progress HMAC key successfully derived
0xA3 Progress Master got Boot Mode and sent boot mode to all slaves
0xA4 Progress SpiRom successfully initialized
0xA5 Progress BIOS Directory successfully read from SPI to SRAM
0xA6 Progress Early unlock check
0xA7 Progress Inline Aes key successfully derived
0xA8 Progress Inline-AES key programming is done
0xA9 Progress Inline-AES key wrapper derivation is done
0xAA Progress Bootloader successfully loaded HW IP configuration values
0xAB Progress Bootloader successfully programmed MBAT table
0xAC Progress Bootloader successfully loaded SMU FW
0xAD Progress PSP and SMU configured WAFL
0xAE Progress User mode test harness completed successfully
0xAF Progress Bootloader loaded Agesa0 from SpiRom
0xB0 Progress AGESA phase has completed
0xB1 Progress RunPostDramTrainingTests() completed successfully
0xB2 Progress SMU FW Successfully loaded to SMU Secure DRAM
0xB3 Progress Sent all required boot time messages to SMU
0xB4 Progress Validated and ran Security Gasket binary
0xB5 Progress UMC Keys generated and programmed
0xB6 Progress Inline AES key wrapper stored in DRAM
0xB7 Progress Completed FW Validation step
0xB8 Progress Completed FW Validation step
0xB9 Progress BIOS copy from SPI to DRAM complete
0xBA Progress Completed FW Validation step
0xBB Progress BIOS load process fully complete
0xBC Progress Bootloader successfully release x86
0xBD Progress Early Secure Debug completed
0xBE Progress GetFWVersion command received from BIOS is completed
0xBF Progress SMIInfo command received from BIOS is completed
0xC0 Progress Successfully entered WarmBootResume()
0xC1 Progress Successfully copied SecureOS image to SRAM
0xC2 Progress Successfully copied trustlets to PSP Secure Memory
0xC3 Progress About to jump to Secure OS (SBL about to copy and jump)
0xC4 Progress Successfully restored CCP and UMC state on S3 resume
0xC5 Progress PSP SRAM HMAC validated by Mini BL
0xC6 Progress About to jump to <t-base in Mini BL
0xC7 Progress VMG ECDH unit test started
0xC8 Progress VMG ECDH unit test passed
0xC9 Progress VMG ECC CDH primitive unit test started
0xCA Progress VMG ECC CDH primitive unit test passed
0xCB Progress VMG SP800-108 KDF-CTR HMAC unit test started
0xCC Progress VMG SP800-108 KDF-CTR HMAC unit test passed
0xCD Progress VMG LAUNCH_* test started
0xCE Progress VMG LAUNCH_* test passed
0xCF Progress MP1 has been taken out of reset
0xD0 Progress PSP and SMU Reserved Addresses correct
0xD1 Progress Reached Naples steady-state WFI loop
0xD2 Progress Knoll device successfully initialized
0xD3 Progress 32-byte RandOut successfully returned from Knoll
0xD4 Progress 32-byte MAC successfully received from Knoll.
0xD5 Progress Knoll device verified successfully
0xD6 Progress Done enabling power for Knoll
0xD7 Progress Enter recovery mode due to trustlet validation fail.
0xD8 Progress Enter recovery mode due to OS validation fail.
0xD9 Progress Enter recovery mode due to OEM public key not found.
(continued on the next page)
ASUS RS700A-E11 Series 1-15
Action PHASE POST CODE TYPE DESCRIPTION
Quick VGA
PEI(Pre-EFI
Initialization) phase
0x10 Progress PEI Core Entry
0x11 Progress PEI cache as ram CPU initial
0x15 Progress NB Initialization before installed memory
0x19 Progress SB Initialization before installed memory
DXE(Driver
Execution
Environment)
phase
0x32 Progress CPU POST-Memory Initialization
0x33 Progress CPU Cache Initialization
0x34 Progress Application Processor(s) (AP) Initialization
0x35 Progress BSP Selection
0x36 Progress CPU Initialization
0x37 Progress Pre-memory NB Initialization
0x3B Progress Pre-memory SB Initialization
0x4F Progress DXE Initial Program Load(IPL)
0x60 Progress DXE Core Started
0x61 Progress DXE NVRAM Initialization
0x62 Progress SB run-time Initialization
0x63 Progress CPU DXE Initialization
0x68 Progress PCI HB Initialization
0x69 Progress NB DXE Initialization
0x6A Progress NB DXE SMM Initialization
0x70 Progress SB DXE Initialization
0x71 Progress SB DXE SMM Initialization
0x72 Progress SB DEVICES Initialization
0x78 Progress ACPI Module Initialization
0x79 Progress CSM Initialization
0xD0 Progress CPU PM Structure Initialization
Normal boot
BDS(Boot Device
Selection) phase
0x90 Progress BDS started
0x91 Progress Connect device event
0x92 Progress PCI Bus Enumeration
0x93 Progress PCI Bus Enumeration
0x94 Progress PCI Bus Enumeration
0x95 Progress PCI Bus Enumeration
0x96 Progress PCI Bus Enumeration
0x97 Progress Console outout connect event
0x98 Progress Console input connect event
0x99 Progress AMI Super IO start
0x9A Progress AMI USB Driver Initialization
0x9B Progress AMI USB Driver Initialization
0x9C Progress AMI USB Driver Initialization
0x9D Progress AMI USB Driver Initialization
0xb2 Progress Legacy Option ROM Initialization
0xb3 Progress Reset system
0xb4 Progress USB hotplug
0xb6 Progress NVRAM clean up
0xb7 Progress NVRAM configuration reset
0xA0 Progress IDE, AHCI Initialization
0xA1 Progress IDE, AHCI Initialization
0xA2 Progress IDE, AHCI Initialization
0xA3 Progress IDE, AHCI Initialization
0x00~0xFF Progress Wait BMC ready
0xA8 Progress BIOS Setup Utility password verify
0xA9 Progress BIOS Setup Utility start
0xAB Progress BIOS Setup Utility input wait
0xAD Progress Ready to boot event
0xAE Progress Legacy boot event
Operating system
phase
0xAA Progress APIC mode
0xAC Progress PIC mode
Chapter 1: Product Introduction
1-16
Action PHASE POST CODE TYPE DESCRIPTION
SEC Start up Security Phase
0x01 Progress First post code
0x02 Progress Load BSP microcode
0x03 Progress Perform early platform Initialization
0x04 Progress Set cache as ram for PEI phase
0x05 Progress Establish Stack
0x06 Progress CPU Early Initialization
PSP Boot
PSP Boot Loader
phase (Error Post
Codes)
0x00 error General - Success
0x01 error Generic Error Code
0x02 error Generic Memory Error
0x03 error Buffer Overflow
0x04 error Invalid Parameter(s)
0x05 error Invalid Data Length
0x06 error Data Alignment Error
0x07 error Null Pointer Error
0x08 error Unsupported Function
0x09 error Invalid Service ID
0x0A error Invalid Address
0x0B error Out of Resource Error
0x0C error Timeout
0x0D error data abort exception
0x0E error prefetch abort exception
0x0F error Out of Boundary Condition Reached
0x10 error Data corruption
0x11 error Invalid command
0x12 error The package type provided by BR is incorrect
0x13 error Failed to retrieve FW header during FW validation
0x14 error Key size not supported
0x15 error Agesa0 verification error
0x16 error SMU FW verification error
0x17 error OEM SINGING KEY verification error
0x18 error Generic FW Validation error
0x19 error RSA operation fail - bootloader
0x1A error CCP Passthrough operation failed - internal status
0x1B error AES operation fail
0x1C error CCP state save failed
0x1D error CCP state restore failed
0x1E error SHA256/384 operation fail - internal status
0x1F error ZLib Decompression operation fail
0x20 error HMAC-SHA256/384 operation fail - internal status
0x21 error Booted from boot source not recognized by PSP
0x22 error PSP directory entry not found
0x23 error PSP failed to set the write enable latch
0x24 error PSP timed out because spirom took too long
0x25 error Cannot find BIOS directory
0x26 error SpiRom is not valid
0x27 error slave die has different security state from master
0x28 error SMI interface init failure
0x29 error SMI interface generic error
0x2A error invalid die ID executes MCM related function
0x2B error invalid MCM configuration table read from bootrom
0x2C error Valid boot mode wasn't detected
0x2D error NVStorage init failure
0x2E error NVStorage generic error
0x2F error MCM 'error' to indicate slave has more data to send
0x30 error MCM error if data size exceeds 32B
0x31 error Invalid client id for SVC MCM call
0x32 error MCM slave status register contains bad bits
0x33 error MCM call was made in a single die environment
0x34 error PSP secure mapped to invalid segment (should be 0x400_0000)
0x35 error No physical x86 cores were found on die
0x36 error Insufficient space for secure OS (range of free SRAM to SVC stack base)
0x37 error SYSHUB mapping memory target type is not supported
0x38 error Attempt to unmap permanently mapped TLB to PSP secure region
0x39 error Unable to map an SMN address to AXI space
(continued on the next page)
AMD EPYC™ 7003 Series processors
ASUS RS700A-E11 Series 1-17
Action PHASE POST CODE TYPE DESCRIPTION
PSP Boot
PSP Boot Loader
phase (Error Post
Codes)
0x3A error Unable to map a SYSHUB address to AXI space
0x3B error The count of CCXs or cores provided by bootrom is not consistent
0x3C error Uncompressed image size doesn't match value in compressed header
0x3D error Compressed option used in case where not supported
0x3E error Fuse info on all dies don't match
0x3F error PSP sent message to SMU; SMU reported an error
0x40 error Function RunPostX86ReleaseUnitTests failed in memcmp()
0x41 error Interface between PSP to SMU not available.
0x42 error Timer wait parameter too large
0x43 error Test harness module reported an error
0x44 error x86 wrote C2PMSG_0 interrupting PSP, but the command has an invalid
format
0x45 error Failed to read from SPI the Bios Directory or Bios Combo Directory
0x46 error Mini-BL, validation of the PSP SRAM image failed on HMAC compare
0x47 error Failed to read the combo bios header
0x48 error Potential stack corruption in jump to Mini BL
0x49 error Error in Validate and Loading AGESA APOB SVC call
0x4A error Correct fuse bits for DIAG_BL loading not set
0x4B error The UmcProgramKeys() function was not called by AGESA
0x4C error Unconditional Unlock based on serial numbers failure
0x4D error Syshub register programming mismatch during readback
0x4E error Family ID in MP0_SFUSE_SEC[7:3] not correct
0x4F error An operation was invoked that can only be performed by the GM
0x50 error Failed to acquire host controller semaphore to claim ownership of SMB
0x51 error Timed out waiting for host to complete pending transactions
0x52 error Timed out waiting for slave to complete pending transactions
0x53 error Unable to kill current transaction on host, to force idle
0x54 error One of: Illegal command, Unclaimed cycle, or Host time out
0x55 error An smbus transaction collision detected, operation restarted
0x56 error Transaction failed to be started or processed by host, or not completed
0x57 error An unsolicited smbus interrupt was received
0x58 error An attempt to send an unsupported PSP-SMU message was made
0x59 error An error/data corruption detected on response from SMU for sent msg
0x5A error MCM Steady-state unit test failed
0x5B error S3 Enter failed
0x5C error AGESA BL did not set PSP SMU reserved addresses via SVC call
0x5E error CcxSecBisiEn not set in fuse RAM
0x5F error Received an unexpected result
0x60 error VMG Storage Init failed
0x61 error failure in mbedTLS user app
0x62 error An error occured whilst attempting to SMN map a fuse register
0x63 error Fuse burn sequence/operation failed due to internal SOC error
0x64 error Fuse sense operation timed out
0x65 error Fuse burn sequence/operation timed out waiting for burn done
0x66 error The PMU FW Public key certificate loading or authentication fails
0x67 error This PSP FW was revoked
0x68 error The platform model/vendor id fuse is not matching the BIOS public key
token
0x69 error The BIOS OEM public key of the BIOS was revoked for this platform
0x6A error PSP level 2 directory not match expected value.
0x6B error BIOS level 2 directory not match expected value.
0x6C error Reset image not found
0x6D error Generic error indicating the CCP HAL initialization failed
0x6E error failure to copy NVRAM to DRAM.
0x6F error Invalid key usage flag
0x71 error RSMU signaled a security violation
0x72 error Error programming the WAFL PCS registers
0x73 error Error setting wafl PCS threshold value
0x74 error Error loading OEM trustlets
0x75 error Recovery mode accross all dies is not sync'd
0x76 error Uncorrectable WAFL error detected
0x77 error Fatal MP1 error detected
0x78 error Bootloader failed to find OEM signature
0x79 error Error copying BIOS to DRAM
0x7A error Error validating BIOS image signature
(continued on the next page)
Chapter 1: Product Introduction
1-18
Action PHASE POST CODE TYPE DESCRIPTION
PSP Boot
PSP Boot Loader
phase (Status Post
Codes)
0x7B error
0x7C error Platform Vendor ID and/or Model ID binding violation
0x7D error Bootloader detects BIOS request boot from SPI-ROM, which is unsupported
for PSB.
0x7E error Requested fuse is already blown, reblow will cause ASIC malfunction
0x7F error Error with actual fusing operation
0x80 error (Local Master PSP on P1 socket) Error reading fuse info
0x81 error (Local Master PSP on P1 socket) Platform Vendor ID and/or Model ID
binding violation
0x82 error (Local Master PSP on P1 socket) Requested fuse is already blown, reblow
will cause ASIC malfunction
0x83 error (Local Master PSP on P1 socket) Error with actual fusing operation
0x84 error SEV FW Rollback attempt is detected
0x85 error / SEV download FW command fail to broadcase and clear the IsInSRAM
field on slave dies
0x86 error Agesa error injection failure
0x87 error Uncorrectable TWIX error detected
0x88 error Error programming the TWIX PCS registers
0x89 error Error setting TWIX PCS threshold value
0x8A error SW CCP queue is full, cannot add more entries
0x8B error CCP command description syntax error detected from input
0x8C error Return value stating that the command has not yet be scheduled
0x8D error The command is scheduled and being worked on
0x8E error The DXIO PHY SRAM Public key certificate loading or authentication fails
0x8F error fTPM binary size exceeds limit allocated in Private DRAM, need to increase
the limit
0x90 error The TWIX link for a particular CCD is not trained Fatal error
0x91 error Security check failed (not all dies are in same security state)
0x92 error FW type mismatch between the requested FW type and the FW type
embedded in the FW binary header
0x93 error SVC call input parameter address violation
0x94 error Knoll failed to idle correctly after being reset
0x95 error Bad status returned by I2CKnollCheck
0x96 error NACK to general call (no device on Knoll I2C bus)
0x97 error Null pointer passed to I2CKnollCheck
0x98 error Invalid device-ID found during Knoll authentication
0x99 error Error during Knoll/Prom key derivation
0x9A error Null pointer passed to Crypto function
0x9B error Error in checksum from wrapped Knoll/Prom keys
0x9C error Knoll returned an invalid response to a command
0x9D error Bootloader failed in Knoll Send Command function
0x9E error No Knoll device found by verifying MAC
0x9F error The maximum allowable error post code
Quick VGA
PEI(Pre-EFI
Initialization) phase
0x10 Progress PEI Core Entry
0x11 Progress PEI cache as ram CPU initial
0x15 Progress NB Initialization before installed memory
0x19 Progress SB Initialization before installed memory
DXE(Driver
Execution
Environment)
phase
0x32 Progress CPU POST-Memory Initialization
0x33 Progress CPU Cache Initialization
0x34 Progress Application Processor(s) (AP) Initialization
0x35 Progress BSP Selection
0x36 Progress CPU Initialization
0x37 Progress Pre-memory NB Initialization
0x3B Progress Pre-memory SB Initialization
0x4F Progress DXE Initial Program Load(IPL)
0x60 Progress DXE Core Started
0x61 Progress DXE NVRAM Initialization
0x62 Progress SB run-time Initialization
0x63 Progress CPU DXE Initialization
0x68 Progress PCI HB Initialization
0x69 Progress NB DXE Initialization
0x6A Progress NB DXE SMM Initialization
0x70 Progress SB DXE Initialization
0x71 Progress SB DXE SMM Initialization
0x72 Progress SB DEVICES Initialization
0x78 Progress ACPI Module Initialization
0x79 Progress CSM Initialization
0xD0 Progress CPU PM Structure Initialization
(continued on the next page)
ASUS RS700A-E11 Series 1-19
Action PHASE POST CODE TYPE DESCRIPTION
Normal boot
BDS(Boot Device
Selection) phase
0x90 Progress BDS started
0x91 Progress Connect device event
0x92 Progress PCI Bus Enumeration
0x93 Progress PCI Bus Enumeration
0x94 Progress PCI Bus Enumeration
0x95 Progress PCI Bus Enumeration
0x96 Progress PCI Bus Enumeration
0x97 Progress Console outout connect event
0x98 Progress Console input connect event
0x99 Progress AMI Super IO start
0x9A Progress AMI USB Driver Initialization
0x9B Progress AMI USB Driver Initialization
0x9C Progress AMI USB Driver Initialization
0x9D Progress AMI USB Driver Initialization
0xb2 Progress Legacy Option ROM Initialization
0xb3 Progress Reset system
0xb4 Progress USB hotplug
0xb6 Progress NVRAM clean up
0xb7 Progress NVRAM configuration reset
0xA0 Progress IDE, AHCI Initialization
0xA1 Progress IDE, AHCI Initialization
0xA2 Progress IDE, AHCI Initialization
0xA3 Progress IDE, AHCI Initialization
0x00~0xFF Progress Wait BMC ready
0xA8 Progress BIOS Setup Utility password verify
0xA9 Progress BIOS Setup Utility start
0xAB Progress BIOS Setup Utility input wait
0xAD Progress Ready to boot event
0xAE Progress Legacy boot event
Operating system
phase
0xAA Progress APIC mode
0xAC Progress PIC mode
Chapter 1: Product Introduction
1-20
This chapter lists the hardware setup procedures that you have
to perform when installing or removing system components.
2
Hardware Information
Chapter 2: Hardware Information
Chapter 2: Hardware Information
2-2
2.1 Chassis cover
2.1.1 Removing the rear cover
1. Remove the two (2) screws on both sides of the cover with a Phillips screwdriver.
2. Loosen the thumbscrew on the rear panel to release the cover from the chassis.
3. Firmly hold the cover and slide it towards the rear panel for about half an inch until it is
disengaged from the chassis.
4. Lift the cover from the chassis.
2-3
ASUS RS700A-E11 Series
2.2 Air ducts
2.2.1 Removing the air ducts
Gently lift the air ducts vertically out of the chassis.
2.2.2 Installing the air ducts
Align the air ducts along the edges of the DIMM slots, then place the air ducts in the chassis,
and ensure they are fitted firmly into the chassis.
Chapter 2: Hardware Information
2-4
2.3 Central Processing Unit (CPU)
The motherboard comes with a surface mount Socket SP3 designed for the AMD EPYC™
7002/7003 Series.
• Upon purchase of the motherboard, ensure that the PnP cap is on the socket and
the socket contacts are not bent. Contact your retailer immediately if the PnP cap
is missing, or if you see any damage to the PnP cap/socket contacts/motherboard
components. ASUS will shoulder the cost of repair only if the damage is shipment/
transit-related.
• Keep the cap after installing the motherboard. ASUS will process Return Merchandise
Authorization (RMA) requests only if the motherboard comes with the cap on the
Socket SP3.
• The product warranty does not cover damage to the socket contacts resulting from
incorrect CPU installation/removal, or misplacement/loss/incorrect removal of the PnP
cap.
2.3.1 Installing the CPU and heatsink
To install the CPU and heatsink:
1. Remove the rear cover. For more information, refer to Chassis cover.
2. Remove the air ducts. For more information, refer to Air ducts.
3. Loosen each screw one by one in the
sequence shown on the socket to open
the load plate.
2-5
ASUS RS700A-E11 Series
4. Slightly lift open the rail frame.
External cap
Load plate
Rail frame
5. Slide the external cap out of the rail
frame.
Rail frame
External cap
PnP cap
6. Slide the carrier frame with CPU into the
rail frame, then remove the PnP cap.
The carrier frame with CPU fits in only
one correct orientation. DO NOT force
the carrier frame with CPU into the
rail frame.
Rail frame
Carrier frame
with CPU
PnP cap
Chapter 2: Hardware Information
2-6
7. Gently push the rail frame just enough
to let it sit on top of the CPU socket.
8. Close the load plate just enough to let
it sit on top of the CPU, then secure
each screw one by one in the sequence
shown on the socket to completely
secure the load plate.
The load plate screws are
T20 models. A torque value of
16.1±1.2 kgf-cm (14.0±1.0 lbf-in) is
recommended.
Carrier frame
with CPU
9. Twist each of the four screws with a
screwdriver just enough to attach the
heatsink to the motherboard. When the
four screws are attached, tighten them
one by one in the sequence shown in
the illustration to completely secure the
heatsink.
The heatsink screws are T20 models.
A torque value of 16.1±1.2 kgf-cm
(14.0±1.0 lbf-in) is recommended.
10. Reinstall the air ducts to complete the CPU and heatsink installation. For more
information, refer to Air ducts.
2-7
ASUS RS700A-E11 Series
2.4 System memory
2.4.1 Overview
The motherboard comes with 32 Double Data Rate 4 (DDR4) Dual Inline Memory Modules
(DIMM) sockets.
The figure illustrates the location of the DDR4 DIMM sockets:
Chapter 2: Hardware Information
2-8
2.4.2 Memory Configurations
You may install 16GB, 32GB, and 64GB RDIMMs; 64GB and 128GB LRDIMM; or 64GB,
128GB, 256GB LRDIMM 3DS / 3DS RDIMM into the DIMM sockets. If you are not sure on
which slots to install the DIMMS, you can use the recommended memory configuration in this
section for reference.
• Refer to ASUS Server AVL for the updated list of compatible DIMMs.
• Always install DIMMs with the same CAS latency. For optimum compatibility, it is
recommended that you obtain memory modules from the same vendor.
• Start installing the DIMMs into the second slots (such as DIMM_A2 , DIMM_B2, etc.)
Recommended dual CPU configuration
DIMMs
2 4 8 16 32
DIMM_P2 • • •
DIMM_P1 •
DIMM_O2 • • •
DIMM_O1 •
DIMM_N2 • •
DIMM_N1 •
DIMM_M2 • •
DIMM_M1 •
DIMM_I1 •
DIMM_I2 • •
DIMM_J1 •
DIMM_J2 • •
DIMM_K1 •
DIMM_K2 • • • • •
DIMM_L1 •
DIMM_L2 • • • •
DIMM_H2 • • •
DIMM_H1 •
DIMM_G2 • • •
DIMM_G1 •
DIMM_F2 • •
DIMM_F1 •
DIMM_E2 • •
DIMM_E1 •
DIMM_A1 •
DIMM_A2 • •
DIMM_B1 •
DIMM_B2 • •
DIMM_C1 •
DIMM_C2 • • • • •
DIMM_D1 •
DIMM_D2 • • • •
2-9
ASUS RS700A-E11 Series
2.4.3 Installing a DIMM
3. Hold the DIMM by both of its ends
then insert the DIMM vertically into
the socket. Apply force to both ends
of the DIMM simultaneously until the
retaining clips snaps back into place.
Ensure that the DIMM is sitting firmly
on the DIMM slot.
Ensure to unplug the power supply before adding or removing DIMMs or other system
components. Failure to do so may cause severe damage to both the motherboard and the
components.
1. Unlock a DIMM socket by pressing
the retaining clips outward.
2. Align a DIMM on the socket such that
the notch on the DIMM matches the
DIMM slot key on the socket.
A DIMM is keyed with a notch so that it fits in only one direction. DO NOT force a DIMM into
a socket in the wrong direction to avoid damaging the DIMM.
Always insert the DIMM into the socket VERTICALLY to prevent DIMM notch damage.
Locked Retaining Clip
Unlocked retaining clip
DIMM notch
DIMM slot key
2.4.4 Removing a DIMM
2. Simultaneously press the retaining
clips outward to unlock the DIMM.
3. Remove the DIMM from the socket.
Support the DIMM lightly with your fingers when pressing the retaining clips. The DIMM
might get damaged when it flips out with extra force.
1. Remove the chassis cover. For more information, see the section Chassis cover.
Chapter 2: Hardware Information
2-10
2.5 Storage devices
The system supports twelve (12) 2.5” hot-swap SATA/SAS/NVMe storage devices (up to 8 x
NVMe/SAS/SATA + 4 x NVMe/SATA). The storage device installed on the storage device tray
connects to the motherboard SATA/SAS/NVMe ports via the SATA/SAS/NVMe backplane.
Spring lock
Tray lever
• Bay 1 to bay 8 supports NVMe/SATA by default. SAS support requires optional ASUS
PIKE II card.
• Bay 9 to bay 12 supports NVMe/SATA by default.
• All bays support 2.5” drives with trays.
Bay 1 Bay 3 Bay 5 Bay 7 Bay 9 Bay 11
Bay 2 Bay 4 Bay 6 Bay 10Bay 8 Bay 12
2.5.1 To install a 2.5” hot-swap SATA/SAS/NVMe storage
device:
1. Push the spring lock to the right (A) then pull the tray lever outward (B) to release the
storage device tray. The storage device tray ejects slightly after you pull out the lever.
2-11
ASUS RS700A-E11 Series
2. Firmly hold the tray lever and pull the storage device tray out of the bay.
3. Prepare the 2.5” storage device and the bundled set of screws.
4. Place the 2.5” storage device into the storage device tray then secure it with four
screws.
5. Push the storage device tray and HDD assembly all the way into the depth of the bay
until the tray lever and spring lock clicks and secures the storage device tray in place.
• When installed, the SATA/SAS/NVMe connector on the storage device connects to the
SATA/SAS/NVMe interface on the backplane.
• The storage device tray is correctly placed when its front edge aligns with the bay
edge.
6. Repeat steps 1 to 5 to install the other SATA/SAS/NVMe storage devices.
Chapter 2: Hardware Information
2-12
2.6 Expansion slot
The barebone server comes with two PCIE slots - PCIE1 and PCIE2. These slots are pre-
installed with a riser card bracket and a butterfly riser card bracket for installing PCIE
expansion cards. You need to remove these expansion card brackets if you want to install
PCIE expansion cards.
2.6.1 Installing an expansion card to the PCIe riser card
bracket
The pre-installed PCIe riser card bracket on the PCIE1 slot has two PCIe x16 slots and one
PCIe x8 slot. The two PCIe x16 slots provides x16 Gen4 links, with the top PCIe slot’s signal
provided from CPU1 and the bottom PCIe slot’s signal coming from CPU2. The PCIe x8 slot
is reserved only for a PIKE II card.
To install PCIe x16 (Gen4 x16 link), proprietary cards such as a graphics card to the PCIe
riser card bracket:
1. Remove the butterfly riser card bracket installed on the PCIE2 slot. For more
information please refer to Installing an expansion card to the butterfly riser card
bracket.
2. Loosen the thumbscrews (A) securing the PCIe riser card bracket to the chassis, then
lift the PCIe riser card bracket out of the chassis by firmly holding it by the two tabs (B)
and pulling it upwards to detach it from the PCIe x16 slot on the motherboard.
2-13
ASUS RS700A-E11 Series
3. Remove the pre-installed PIKE II card. For more information please refer to Installing
an ASUS PIKE II card.
4. Disconnect the two (2) Slimline PCIe cables from the slim PCIe connectors on the PCIe
riser card bracket.
5. Prepare your expansion card and flip the PCIe riser card bracket over.
6. Flip the metal bracket lock open (A) then slide the two metal brackets out of the PCIe
riser card bracket and remove them.
Chapter 2: Hardware Information
2-14
8. Install your expansion card to the PCIe x16 slot on the PCIe riser card bracket. The
illustration below is an example of a graphics card.
7. (optional) Install the GPU back bracket to the location shown in the illustration below
using two (2) screws.
Follow this step only if you are installing a graphics card.
9. Once your expansion card is installed, flip the metal bracket lock back to secure the
expansion card to the PCIe riser card bracket.
2-15
ASUS RS700A-E11 Series
10. Connect the two (2) slimline PCIe cables previously removed to the slim PCIe
connectors on the PCIe riser card bracket. Ensure to connect the cable labeled 7 to
the slim PCIe connector labeled 7 and connect the cable labeled 8 to the slim PCIe
connector labeled 8.
11. Install the PIKE II card previously removed. For more information please refer to
Installing an ASUS PIKE II card.
Chapter 2: Hardware Information
2-16
12. Align the PCIe riser card bracket to the notch holes on the chassis and the PCIE1 slot
on the motherboard, then push the PCIe riser card bracket down until it is seated firmly
in the chasiss.
Ensure that no cables are below or in the way of the PCIe riser card bracket when installing
it to the chassis.
13. Secure the PCIe riser card bracket with the thumbscrews.
14. Replace the butterfly riser card bracket. For more information please refer to Installing
an expansion card to the butterfly riser card bracket.
2-17
ASUS RS700A-E11 Series
2.6.2 Installing an OCP 3.0 slot baseboard and OCP 3.0
card to the PCIe riser card bracket
We recommend you install the OCP 3.0 slot baseboard to the PCIE2 slot on the PCIe riser
card bracket.
To install the OCP 3.0 slot baseboard and OCP 3.0 card to the PCIe riser card bracket:
1. Follow steps 1-6 of the Installing an expansion card to the PCIe riser card bracket
section to remove the PCIe riser card bracket and metal brackets.
2. Remove the screw securing the Raiser PCIe bracket.
3. Remove the Raiser PCIe bracket.
4. Install the OCP 3.0 slot baseboard to the PCIE2 slot on the PCIe riser card bracket.
Raiser PCIe bracket
Chapter 2: Hardware Information
2-18
6. Insert the OCP 3.0 card to the OCP 3.0 slot from the rear of the PCIe riser card
bracket, and make sure the OCP 3.0 card is seated securely in the OCP 3.0 slot.
7. Once your OCP 3.0 card is installed, flip the metal bracket lock back to secure the OCP
3.0 slot baseboard to the PCIe riser card bracket.
8. Follow steps 10-13 of the Installing an expansion card to the PCIe riser card
bracket section to install the PCIe riser card bracket to the chassis.
5. Connect the cables on your OCP 3.0 slot baseboard to the PCIe riser card bracket.
2-19
ASUS RS700A-E11 Series
To install a PCIE x16 (Gen4 x16 link) expansion card on the butterfly riser card bracket:
1. Loosen the thumbscrew (A) securing the butterfly riser card bracket to the chassis,
then lift the butterfly riser out of the chassis by firmly holding it by the tab and pulling it
upwards to detach it from the PCIE x16 slot on the motherboard.
2.6.3 Installing an expansion card to the butterfly riser card
bracket
The pre-installed butterfly riser card bracket on the PCIE2 slot supports Low Profile (LP),
Half-Length (HL) PCIE x16 expansion cards.
Chapter 2: Hardware Information
2-20
2. Flip the butterfly riser card bracket over and remove metal bracket.
3. Install the expansion card to your butterfly riser card bracket.
2-21
ASUS RS700A-E11 Series
4. Align the butterfly riser card bracket to the PCIEX2 slot on the motherboard and push
down until the butterfly riser card bracket is seated securely in the chassis.
5. Secure the butterfly riser card bracket to the chassis using the thumbscrew.
Chapter 2: Hardware Information
2-22
To install a 4-port Intel® I350-AM4 1G LAN controller expansion card or 2-port Intel® X710-
AT2 Gigabit 10G LAN controller expansion card on the butterfly riser card bracket:
1. Follow step 1 of Installing an expansion card to the butterfly riser card bracket to
remove the butterfly riser card bracket from the chassis.
2. Flip the butterfly riser card bracket over and insert the 4-port Intel® I350-AM4 1G
LAN controller expansion card or 2-port Intel® X710-AT2 Gigabit 10G LAN controller
expansion card to the PCIE_LAN1 slot (A) on the butterfly riser card bracket, then
secure it using two (2) screws (B).
2.6.4 Installing an ethernet expansion card to the butterfly
riser card bracket
The pre-installed butterfly riser card bracket can support a 4-port Intel® I350-AM4 1G LAN
controller expansion card or 2-port Intel® X710-AT2 Gigabit 10G LAN controller expansion
card.
Do not install the 4-port Intel® I350-AM4 1G LAN controller expansion card if you wish to
install the external rear fan.
2-port Intel® X710-AT2 Gigabit 10G
LAN controller expansion card 4-port Intel® I350-AM4 1G
LAN controller expansion card
3. Follow step 4-5 of Installing an expansion card to the butterfly riser card bracket
to install the butterfly riser card bracket to the chassis.
2-23
ASUS RS700A-E11 Series
2.6.5 Installing an ASUS PIKE II card
You can replace the pre-installed ASUS PIKE II card to support SAS storage devices in your
server system
.
To remove an ASUS PIKE II card:
1. Follow steps 1 and 2 of Installing an expansion card to the butterfly riser card
bracket to remove the butterfly riser card bracket from the chassis.
2. Remove the mini SAS HD cables from the ASUS PIKE II card.
3. Loosen the thumbscrew, then remove the ASUS PIKE II card.
Chapter 2: Hardware Information
2-24
To install an ASUS PIKE II card:
1. Prepare the new ASUS PIKE II card.
2. Remove the two screws on the new
ASUS PIKE II card (A), then remove the
card bracket (B).
Metal cover
4. Secure the metal cover (proprietary
card bracket) to the new ASUS PIKE II
card with the screw removed previously.
3. Remove the screw securing the metal
cover (proprietary card bracket), then
remove the metal cover (proprietary
card bracket) from the old ASUS PIKE II
card.
Card bracket
Metal cover
2-25
ASUS RS700A-E11 Series
6. Connect the mini SAS HD cables to the ASUS PIKE II card.
7. Follow steps 12 and 13 of Installing an expansion card to the PCIe riser card
bracket to install the PCIe riser card bracket to the chassis.
5. Insert the ASUS PIKE II card to the PCIe slot on the PCIe riser card bracket, then
secure it to the PCIe riser card bracket using the thumbscrew.
Chapter 2: Hardware Information
2-26
2.6.6 Installing an M.2 (NGFF) card
1. Remove the riser card bracket. Please refer to Installing an expansion card to the
butterfly riser card bracket for more information.
2. Locate the M.2 connector (NGFF1 or NGFF2) on the motherboard.
You may install an M.2 card (supports up to 22110) to the onboard M.2 (NGFF) slot on the
motherboard.
3. Select an appropriate screw hole on the motherboard for your M.2 card, then secure
the bundled stand to the motherboard.
4. Insert the M.2 into the M.2 (NGFF) slot, then secure it using the bundled screw.
2-27
ASUS RS700A-E11 Series
2.6.7 Configuring an expansion card
After installing the expansion card, configure it by adjusting the software settings.
1. Turn on the system and change the necessary BIOS settings, if any. See Chapter 5 for
information on BIOS setup.
2. Assign an IRQ to the card. Refer to the following tables.
3. Install the software drivers for the expansion card.
Standard Interrupt assignments
* These IRQs are usually available for ISA or PCI devices.
IRQ Priority Standard function
0 1 System Timer
1 2 Keyboard Controller
2 - Programmable Interrupt
3* 11 Communications Port (COM2)
4* 12 Communications Port (COM1)
5* 13 --
6 14 Floppy Disk Controller
7* 15 --
8 3 System CMOS/Real Time Clock
9* 4 ACPI Mode when used
10* 5 IRQ Holder for PCI Steering
11* 6 IRQ Holder for PCI Steering
12* 7 PS/2 Compatible Mouse Port
13 8 Numeric Data Processor
14* 9 Primary IDE Channel
15* 10 Secondary IDE Channel
Chapter 2: Hardware Information
2-28
2.7 Cable connections
• The bundled system cables are pre-connected before shipment. You do not need to
disconnect these cables unless you are going to remove pre-installed components to
install additional devices.
• Refer to Chapter 4 for detailed information on the connectors.
Pre-connected system cables
1. 4-pin BPPWR1 power connector (connected to backplane)
2. 8-pin BPPWR2 power connector (connected to backplane)
3. 8-pin VGA power connectors (connected to Graphics card, on selected models)
4. Panel connector (connected to front I/O board)
5. System fan connectors (from motherboard FAN1-8 to system fans)
6. SLMPCIE2, SLMPCIE3, SLMPCIE4, SLMPCIE5, SLMPCIE6, SLMPCIE9, SLMPCIE10
Slim PCIe connectors (connected to backplane)
7. SLMPCIE7, SLMPCIE8 Slim PCIe connectors (connected to PCIe riser card)
2-29
ASUS RS700A-E11 Series
2.8 Backplane cabling
Connects to NVMe/SAS/SATA storage
devices (SAS support requires an
optional ASUS PIKE II card)
Connects to NVMe/SATA
storage devices
Connects to ASUS PIKE II
card for SAS support on
Bay 5 to Bay 8 or to the
ISATA2 connector on the
motherboard for SATA
support on Bay 5 to Bay 8
Connects to SLMPCIE6 connector
on motherboard for NVMe support
on Bay 11 and Bay 12
Connects to SLMPCIE9 connector
on motherboard for NVMe support
on Bay 7 and Bay 8
Connects to SLMPCIE10 connector
on motherboard for NVMe support
on Bay 9 and Bay 10
Connects to 8-pin
plug on motherboard
Connects to 4-pin
plug on motherboard
Connects to ASUS PIKE II
card for SAS support on
Bay 1 to Bay 4 or to the
ISATA1 connector on the
motherboard for SATA
support on Bay 1 to Bay 4
Connects to SLMPCIE2 connector
on motherboard for NVMe support
on Bay 5 and Bay 6
Connects to SLMPCIE4 connector
on motherboard for NVMe support
on Bay 3 and Bay 4
Connects to SLMPCIE3 connector
on motherboard for NVMe support
on Bay 1 and Bay 2
Connects to SLMPCIE5
connector on the
motherboard for SATA
support on Bay 9 to
Bay 12
Chapter 2: Hardware Information
2-30
2.9 Storage device configuration and cabling
This section illustrates some storage configurations that is recommended with your server
system. Before you start installing or removing the storage device cables, ensure that you
have installed the correct storage devices into the supported bays.
Refer to section Storage Devices for details on how to install storage devices.
• Bay 1 to bay 8 supports NVMe/SATA by default. SAS support requires optional ASUS
PIKE II card.
• Bay 9 to bay 12 supports NVMe/SATA by default.
• All bays support 2.5” drives with trays.
Bay 1 Bay 3 Bay 5 Bay 7 Bay 9 Bay 11
Bay 2 Bay 4 Bay 6 Bay 10Bay 8 Bay 12
2-31
ASUS RS700A-E11 Series
1. Install the storage devices into the supported bays.
Refer to section Storage Devices for details on how to install storage devices.
SATA SATA SATA SATA SATA SATA
SATA SATA SATA SATA
SATA SATA
2. Remove the six (6) screws of the rack screw on both sides of the chassis with a Phillips
screwdriver (A), then remove the rack screws on both sides of the chassis (B).
Backplane connector Cable Connect to
MSAS_HD1 Mini-SAS HD (vertical) to
Mini-SAS HD (vertical) ISATA1 on motherboard
MSAS_HD2 Mini-SAS HD (vertical) to
Mini-SAS HD (vertical) ISATA2 on motherboard
MSAS_HD3 Mini-SAS HD (vertical) to
Slimline PCIe SLMPCIE5 on motherboard
2.9.1 12 x SATA storage device configuration and cabling
• The illustrations in this section are for reference only and may vary between models.
• You may still support 4, 6 or 12 NVMe bays with this configuration, for more
information please refer to the following sections:
- 4 NVMe support: 4 x NVMe storage device configuration and cabling
- 8 NVMe support: 8 x NVMe storage device configuration and cabling
- 12 NVMe support: 12 x NVMe storage device configuration and cabling
Chapter 2: Hardware Information
2-32
Backplane
4. Lift the front cover to reveal the backplane (A), then cut the cable tie(s) (B).
3. Remove the six (6) screws on both sides of the front cover with a Phillips screwdriver (A),
then firmly hold the front cover and slide it towards the front panel until it is disengaged
from the chassis (B).
2-33
ASUS RS700A-E11 Series
5. Connect the mini-SAS HD cables to the motherboard and the backplane.
MSAS_HD2: Connect
mini-SAS HD cable from
the ISATA2 connector
on the motherboard
MSAS_HD3: Connect
mini-SAS HD to Slimline
PCIe cable from the
SLMPCIE5 connector on
the motherboard
MSAS_HD1: Connect
mini-SAS HD cable from
the ISATA1 connector
on the motherboard
6. Tie the cables with cable tie(s) (A), then reinstall the front cover back into the chassis (B).
Backplane
Chapter 2: Hardware Information
2-34
7. Firmly hold the front cover and slide it towards the rear panel until it is locked in the
chassis (A), then secure the front cover with the screws removed earlier (B).
8. Align the rack screws to the chassis then secure the rack screw to the chassis using
the screws removed earlier.
2-35
ASUS RS700A-E11 Series
Backplane connector Cable Connect to
SLMPCIE1 Slimline PCIe to Slimline PCIe SLMPCIE3 on motherboard
SLMPCIE2 Slimline PCIe to Slimline PCIe SLMPCIE4 on motherboard
2.9.2 4 x NVMe storage device configuration and cabling
1. Install the storage devices into the supported bays.
Refer to section Storage Devices for details on how to install storage devices.
NVMe NVMe
NVMe NVMe
2. Remove the six (6) screws of the rack screw on both sides of the chassis with a Phillips
screwdriver (A), then remove the rack screws on both sides of the chassis (B).
• The illustrations in this section are for reference only and may vary between models.
• You may still support either SATA for bays 1 to 12 or SAS for bays 1 to 8 with this
configuration, for more information please refer to the following sections:
- SATA support for bays 1 to 12: 12 x SATA storage device configuration and
cabling
- SAS support for bays 1 to 8 and SATA support for bays 9 to 12: 8 x SAS and 4 x
SATA storage device configuration and cabling
Chapter 2: Hardware Information
2-36
Backplane
4. Lift the front cover to reveal the backplane (A), then cut the cable tie(s) (B).
3. Remove the six (6) screws on both sides of the front cover with a Phillips screwdriver (A),
then firmly hold the front cover and slide it towards the front panel until it is disengaged
from the chassis (B).
2-37
ASUS RS700A-E11 Series
5. Connect the slimline PCIe cables to the motherboard and the backplane.
SLMPCIE2: Connect
slimline PCIe cable
from the SLMPCIE4
connector on the
motherboard
SLMPCIE1: Connect
slimline PCIe cable
from the SLMPCIE3
connector on the
motherboard
6. Tie the cables with cable tie(s) (A), then reinstall the front cover back into the chassis (B).
Backplane
Chapter 2: Hardware Information
2-38
7. Firmly hold the front cover and slide it towards the rear panel until it is locked in the
chassis (A), then secure the front cover with the screws removed earlier (B).
8. Align the rack screws to the chassis then secure the rack screw to the chassis using
the screws removed earlier.
2-39
ASUS RS700A-E11 Series
2.9.3 8 x NVMe storage device configuration and cabling
• The illustrations in this section are for reference only and may vary between models.
• You may still support either SATA for bays 1 to 12 or SAS for bays 1 to 8 with this
configuration, for more information please refer to the following sections:
- SATA support for bays 1 to 12: 12 x SATA storage device configuration and
cabling
- SAS support for bays 1 to 8 and SATA support for bays 9 to 12: 8 x SAS and 4 x
SATA storage device configuration and cabling
Backplane connector Cable Connect to
SLMPCIE3 Slimline PCIe to Slimline PCIe SLMPCIE2 on motherboard
SLMPCIE4 Slimline PCIe to Slimline PCIe SLMPCIE9 on motherboard
SLMPCIE5 Slimline PCIe to Slimline PCIe SLMPCIE10 on motherboard
SLMPCIE6 Slimline PCIe to Slimline PCIe SLMPCIE6 on motherboard
1. Install the storage devices into the supported bays.
Refer to section Storage Devices for details on how to install storage devices.
NVMe NVMe
NVMe NVMe
2. Remove the six (6) screws of the rack screw on both sides of the chassis with a Phillips
screwdriver (A), then remove the rack screws on both sides of the chassis (B).
NVMe
NVMe
NVMe
NVMe
Chapter 2: Hardware Information
2-40
Backplane
4. Lift the front cover to reveal the backplane (A), then cut the cable tie(s) (B).
3. Remove the six (6) screws on both sides of the front cover with a Phillips screwdriver (A),
then firmly hold the front cover and slide it towards the front panel until it is disengaged
from the chassis (B).
2-41
ASUS RS700A-E11 Series
5. Connect the slimline PCIe cables to the motherboard and the backplane.
SLMPCIE4: Connect
slimline PCIe cable
from the SLMPCIE9
connector on the
motherboard
SLMPCIE3: Connect
slimline PCIe cable
from the SLMPCIE2
connector on the
motherboard
SLMPCIE5: Connect
slimline PCIe cable
from the SLMPCIE10
connector on the
motherboard
6. Tie the cables with cable tie(s) (A), then reinstall the front cover back into the chassis (B).
Backplane
SLMPCIE6: Connect
slimline PCIe cable
from the SLMPCIE6
connector on the
motherboard
Chapter 2: Hardware Information
2-42
7. Firmly hold the front cover and slide it towards the rear panel until it is locked in the
chassis (A), then secure the front cover with the screws removed earlier (B).
8. Align the rack screws to the chassis then secure the rack screw to the chassis using
the screws removed earlier.
2-43
ASUS RS700A-E11 Series
2.9.4 12 x NVMe storage device configuration and cabling
• The illustrations in this section are for reference only and may vary between models.
• You may still support one of the following configurations with this configuration, for
more information please refer to the following sections:
- SATA support for bays 1 to 12: 12 x SATA storage device configuration and
cabling
- SAS support for bays 1 to 8 and SATA support for bays 9 to 12: 8 x SAS and 4 x
SATA storage device configuration and cabling
Backplane connector Cable Connect to
SLMPCIE1 Slimline PCIe to Slimline PCIe SLMPCIE3 on motherboard
SLMPCIE2 Slimline PCIe to Slimline PCIe SLMPCIE4 on motherboard
SLMPCIE3 Slimline PCIe to Slimline PCIe SLMPCIE2 on motherboard
SLMPCIE4 Slimline PCIe to Slimline PCIe SLMPCIE9 on motherboard
SLMPCIE5 Slimline PCIe to Slimline PCIe SLMPCIE10 on motherboard
SLMPCIE6 Slimline PCIe to Slimline PCIe SLMPCIE6 on motherboard
1. Install the storage devices into the supported bays.
Refer to section Storage Devices for details on how to install storage devices.
NVMe NVMe
NVMe NVMe
2. Remove the six (6) screws of the rack screw on both sides of the chassis with a Phillips
screwdriver (A), then remove the rack screws on both sides of the chassis (B).
NVMe
NVMe
NVMe
NVMe
NVMe
NVMe
NVMe
NVMe
Chapter 2: Hardware Information
2-44
Backplane
4. Lift the front cover to reveal the backplane (A), then cut the cable tie(s) (B).
3. Remove the six (6) screws on both sides of the front cover with a Phillips screwdriver (A),
then firmly hold the front cover and slide it towards the front panel until it is disengaged
from the chassis (B).
2-45
ASUS RS700A-E11 Series
5. Connect the slimline PCIe cables to the motherboard and the backplane.
SLMPCIE2: Connect
slimline PCIe cable
from the SLMPCIE4
connector on the
motherboard
SLMPCIE1: Connect
slimline PCIe cable
from the SLMPCIE3
connector on the
motherboard
SLMPCIE3: Connect
slimline PCIe cable
from the SLMPCIE2
connector on the
motherboard
6. Tie the cables with cable tie(s) (A), then reinstall the front cover back into the chassis (B).
Backplane
SLMPCIE4: Connect
slimline PCIe cable
from the SLMPCIE9
connector on the
motherboard
SLMPCIE5: Connect
slimline PCIe cable
from the SLMPCIE10
connector on the
motherboard
SLMPCIE6: Connect
slimline PCIe cable
from the SLMPCIE6
connector on the
motherboard
Chapter 2: Hardware Information
2-46
7. Firmly hold the front cover and slide it towards the rear panel until it is locked in the
chassis (A), then secure the front cover with the screws removed earlier (B).
8. Align the rack screws to the chassis then secure the rack screw to the chassis using
the screws removed earlier.
2-47
ASUS RS700A-E11 Series
2.9.5 8 x SAS and 4 x SATA storage device configuration
and cabling
Backplane connector Cable Connect to
MSAS_HD1 Mini-SAS HD (vertical) to
Mini-SAS HD (vertical) ASUS PIKE II Card
MSAS_HD2 Mini-SAS HD (vertical) to
Mini-SAS HD (vertical) ASUS PIKE II Card
MSAS_HD3 Mini-SAS HD (vertical) to
Slimline PCIe SLMPCIE5 on motherboard
• The illustrations in this section are for reference only and may vary between models.
• You may still support 4, 6 or 12 NVMe bays with this configuration, for more
information please refer to the following sections:
- 4 NVMe support: 4 x NVMe storage device configuration and cabling
- 8 NVMe support: 8 x NVMe storage device configuration and cabling
- 12 NVMe support: 12 x NVMe storage device configuration and cabling
1. Install the storage devices into the supported bays.
Refer to section Storage Devices for details on how to install storage devices.
SAS SATA SATA
SAS SATA SATA
SAS
SAS
SAS
SAS
SAS
SAS
2. Install the ASUS PIKE II card to your system. For more information, refer to Installing
an ASUS PIKE II card.
Chapter 2: Hardware Information
2-48
4. Remove the six (6) screws on both sides of the front cover with a Phillips screwdriver (A),
then firmly hold the front cover and slide it towards the front panel until it is disengaged
from the chassis (B).
3. Remove the six (6) screws of the rack screw on both sides of the chassis with a Phillips
screwdriver (A), then remove the rack screws on both sides of the chassis (B).
2-49
ASUS RS700A-E11 Series
5. Lift the front cover to reveal the backplane (A), then cut the cable tie(s) (B).
Backplane
6. Connect the slimline PCIe cables to the motherboard and the backplane.
MSAS_HD2: Connect
mini-SAS HD cable from
the ASUS PIKE II card
MSAS_HD3: Connect
mini-SAS HD to Slimline
PCIe cable from the
SLMPCIE5 connector on
the motherboard
MSAS_HD1: Connect
mini-SAS HD cable from
the ASUS PIKE II card
Chapter 2: Hardware Information
2-50
7. Tie the cables with cable tie(s) (A), then reinstall the front cover back into the chassis (B).
Backplane
8. Firmly hold the front cover and slide it towards the rear panel until it is locked in the
chassis (A), then secure the front cover with the screws removed earlier (B).
2-51
ASUS RS700A-E11 Series
9. Align the rack screws to the chassis then secure the rack screw to the chassis using
the screws removed earlier.
Chapter 2: Hardware Information
2-52
2.10 Removable/optional components
This section explains how to install optional components into the system and covers the
following components:
1. System fans
2. Redundant power supply module
Ensure that the system is turned off before removing any components.
You may need to remove previously installed component or factory shipped components
when installing optional components.
2.10.1 System fans
To uninstall the system fans:
1. Disconnect the system fan cable from the fan connector on the motherboard.
2-53
ASUS RS700A-E11 Series
To reinstall the system fans:
1. Insert the fan into the fan cage. The airflow directional arrow on the fan should point
towards the system rear panel.
Ensure the notches on the fan module is fitted into the notch holes in the chassis.
2. Lift the fan, then set it aside.
3. Repeat steps 1 to 2 to uninstall the other system fans.
Chapter 2: Hardware Information
2-54
2. Connect the system fan cable to the fan connector on the motherboard.
To install the external rear fan:
1. Use a screwdriver to pry open the slot.
Do not install the 4-port ethernet expansion card if you wish to install the external rear fan.
2. Prepare the rear external fan.
3. Connect the cable of the rear external fan to the motherboard through the open slot.
2-55
ASUS RS700A-E11 Series
4. Align and place the rear external fan on the chassis.
5. Secure the rear external fan to the chassis with the thumbscrews.
Chapter 2: Hardware Information
2-56
2.10.2 Redundant power supply module
To replace a failed redundant power supply module:
1. Lift up the power supply module lever.
2. Hold the power supply module lever
and press the PSU latch, then pull the
power supply module out of the system
chassis.
3. Prepare the replacement power supply
module.
4. Insert the replacement power supply
module into the chassis then push it
inwards until the latch locks into place.
Module lever
Module lever PSU latch
This chapter describes how to install the optional components
and devices into the barebone server.
3
Installation Options
Chapter 3: Installation Options
Chapter 3: Installation Options
3-2
3.1 Tool-less Friction Rail Kit
The tool less design of the rail kit allows you to easily install the rack rails into the server rack
without the need for additional tools. The kit also comes with a metal stopping bracket that
can be installed to provide additional support and stability to the server.
The tool-less rail kit package includes:
Tool-less rack rails
3.1.1 Installing the tool-less rack rail
To install the tool-less rack rails into the rack:
1. Secure the two fixing latches to the two sides of the server using the set of latch
screws.
The locations of the screw holes vary with different server models. Refer to your server
user manual for details.
Fixing latches Set of screws Latch screws Rail Washers Rail screws
3-3
ASUS RS700A-E11 Series
2. Select a desired space and place the appropriate rack rail (left and right) on opposite
positions on the rack.
A 1U space is consists of three square mounting holes with two thin lips on the top and the
bottom.
3. Press the spring lock, then insert the studs into the selected square mounting holes on
the rack post.
4. Press the spring lock on the other end of rail then insert the stud into the mounting hole
on the rack post. Extend the rack rail, if necessary.
5. Perform steps 3 to 4 for the other rack rail.
Ensure that the installed rack rails (left and right) are aligned, secured, and stable in place.
Thin lips
Chapter 3: Installation Options
3-4
6. Lift the server chassis and insert it into the rack rail.
• Ensure that the rack rail cabinet and the rack posts are stable and standing firmly on a
level surface.
• We strongly recommend that at least two able-bodied persons perform the steps
described in this guide.
• We recommend the use of an appropriate lifting tool or device, if necessary.
Ensure to include the side knots on the two sides of the server in the rack rail holders.
The illustrations shown above are for reference only.
3.2 Rail kit dimensions
589mm
43.6mm
900mm
43.6mm
3-5
ASUS RS700A-E11 Series
3.3 Cable management arm
(optional for 1200 mm rack rails)
You can install an additional cable management arm (CMA) to the rack rails to help you
manage the cables from your server system. The CMA is designed with movable parts that
allow you to move the server system along the rack rail without the need to remove the CMA.
3.3.1 Attaching the cable management arm
Installing the cable management arm
To install the cable management arm:
1. Install the rack rails into the rack.
Refer to section Rail Kit for the steps on installing the rack rails into the rack.
2. Press the round button on the pivot receptor, then rotate the pivot receptor to the left or
right for a left pivot configuration or right pivot configuration.
Outer receptor
Inner receptor
Pivot receptor
Right pivot configurationLeft pivot configuration
Cable fasteners
Hook and loop fasteners
Chapter 3: Installation Options
3-6
3. Align the three receptors on the CMA with the connectors on the rack rails.
4. Align and connect the inner
receptor on the CMA with the
connector on the inner rail.
5. Align and connect the outer
receptor on the CMA with the
connector on the intermediate
rail.
Intermediate rail connector
Pivot receptor
Inner receptor
Inner rail connector (hidden)
Intermediate rail
connector
Outer receptor
The installation steps in this section uses a Left pivot configuration as an example, the
installation steps for a Right pivot configuration is similar.
3-7
ASUS RS700A-E11 Series
6. Align and connect the pivot receptor on the CMA with the connector on the other
intermediate rail.
7. Pass the cables from the server system through the hook and loop fasteners and the
cable fasteners on the CMA to complete.
Hook and loop fasteners
Cable fasteners
Chapter 3: Installation Options
3-8
This chapter includes the motherboard layout and brief
descriptions of the jumpers and internal connectors.
4
Motherboard Information
Chapter 4: Motherboard Information
Chapter 4: Motherboard Information
4-2
4.1 Motherboard layout
ASUS RS700A-E11 Series 4-3
Layout contents
Jumpers Page
1. Clear RTC RAM (3-pin CLRTC1) 4-4
2. VGA controller setting (3-pin VGA_SW1) 4-5
3. LANNCSI setting (3-pin LANNCSI_SEL1) 4-5
4. Baseboard Management Controller setting (3-pin BMC_EN1) 4-6
5. DMLAN setting (3-pin DM_IP_SEL1) 4-6
6. IPMI SW setting (3-pin IPMI_SW1) 4-7
7. Smart Ride Through (SmaRT) setting (3-pin SMART_PSU1) 4-7
8. System select setting (3-pin SYS_SEL1) 4-8
Onboard LEDs Page
1. Standby Power LED (SBPWR1) 4-9
2. Baseboard Management Controller LED (BMCLED1) 4-9
3. Message LED (MESLED1) 4-10
Internal connectors Page
1. Mini-SAS HD connector (ISATA1-2) 4-11
2. Slim PCIe connector (SLIMPCIE1-10) 4-11
3. USB 2.0 connector (10-1 pin U2_67) 4-12
4. USB 3.2 Gen 1 connector (U31G1_34; U31G1_5) 4-12
5. Chassis Intrusion (2-pin INTRUSION1) 4-13
6. Serial port connector (10-1 pin COM1) 4-13
7. System fan connectors (6-pin FRNT_FAN1-8; 6-pin REAR_FAN1-2) 4-14
8. TPM connector (14-1 pin TPM1) 4-15
9. M.2 (NGFF) card connector (NGFF1-2) 4-15
10. Back panel power connector (4-pin BPPWR1, BPPWR4; 8-pin BPPWR2-3) 4-16
11. VGA power connector (8-pin VGAPWR1-4) 4-16
12. VGA connector (16-pin VGA_HDR1) 4-17
13. Micro SD card slot (MSD1) 4-17
14. System panel connector (10-1 pin PANEL1; 14-1 pin PANEL2) 4-18
15. Hard disk activity LED connector (4-pin HDLED1) 4-19
16. I2C connector (10-1 pin BP_I2C1) 4-20
17. BMC Debug UART connector (3-pin BMC_DEBUGUART1) 4-20
18. CPLD JTAG1 connector (6-pin CPLD_JTAG1) 4-21
19. Liquid connector (12-1 pin LIQUID_CONN1) 4-21
20. SLMPCIE SGPIO connector (6-1 pin SLMPCIE5_SGPIO1) 4-22
Chapter 4: Motherboard Information
4-4
1. Clear RTC RAM (3-pin CLRTC1)
This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can
clear the CMOS memory of date, time, and system setup parameters by erasing the
CMOS RTC RAM data. The onboard button cell battery powers the RAM data in
CMOS, which include system setup information such as system passwords.
To erase the RTC RAM:
1. Turn OFF the computer and unplug the power cord.
2. Move the jumper cap from pins 1–2 (default) to pins 2–3. Keep the cap on pins
2–3 for about 5–10 seconds, then move the cap back to pins 1–2.
3. Plug the power cord and turn ON the computer.
4. Hold down the <Del> key during the boot process and enter BIOS setup to re-
enter data.
Except when clearing the RTC RAM, never remove the cap on CLRTC jumper default
position. Removing the cap will cause system boot failure!
If the steps above do not help, remove the onboard battery and move the jumper again to
clear the CMOS RTC RAM data. After the CMOS clearance, reinstall the battery.
4.2 Jumpers
ASUS RS700A-E11 Series 4-5
2. VGA controller setting (3-pin VGA_SW1)
This jumper allows you to enable or disable the onboard VGA controller. Set to pins
1–2 to activate the VGA feature.
3. LANNCSI setting (3-pin LANNCSI_SEL1)
This jumper allows you to select which LAN NCSI function to use.
Chapter 4: Motherboard Information
4-6
4. Baseboard Management Controller setting (3-pin BMC_EN1)
This jumper allows you to enable (default) or disable on-board BMC. Ensure to set this
BMC jumper to enabled to avoid system fan control and hardware monitor error.
5. DMLAN setting (3-pin DM_IP_SEL1)
This jumper allows you to select the DMLAN setting. Set to pins 2-3 to force the
DMLAN IP to static mode (IP=10.10.10.10, submask=255.255.255.0).
ASUS RS700A-E11 Series 4-7
7. Smart Ride Through (SmaRT) setting (3-pin SMART_PSU1)
This jumper allows you to enable or disable the Smart Ride Through (SmaRT) function.
This feature is enabled by default. Set to pins 2-3 to disable it. When enabled, SmaRT
allows uninterrupted operation of the system during an AC loss event.
6. IPMI SW setting (3-pin IPMI_SW1)
This jumper allows you to select which protocol in the GPU sensor to function.
Chapter 4: Motherboard Information
4-8
8. System select setting (3-pin SYS_SEL1)
This jumper is for toggling between RS700A-E11 or RS720A-E11 configurations.
ASUS RS700A-E11 Series 4-9
4.3 Internal LEDs
1. Standby Power LED (SBPWR1)
The motherboard comes with a standby power LED. The green LED lights up to
indicate that the system is ON, in sleep mode, or in soft-off mode. This is a reminder
that you should shut down the system and unplug the power cable before removing or
plugging in any motherboard component. The illustration below shows the location of
the onboard LED.
2. Baseboard Management Controller LED (BMCLED1)
The BMC LED lights up to indicate that the on-board BMC is functional.
Chapter 4: Motherboard Information
4-10
3. Message LED (MESLED1)
This onboard LED lights up to red when there is a BMC event log is generated.
ASUS RS700A-E11 Series 4-11
4.4 Internal connectors
2. Slim PCIe connector (SLIMPCIE1-10)
Connects the PCIe signal to the front riser card or NVMe port on the backplane.
1. Mini-SAS HD connector (ISATA1-2)
This motherboard comes with mini Serial Attached SCSI (SAS) HD connectors, the
storage technology that supports Serial ATA. Each connector supports up to four
devices.
Chapter 4: Motherboard Information
4-12
3. USB 2.0 connector (10-1 pin U2_67)
This connector is for USB 2.0 ports. Connect the USB module cable to the connector,
and then install the module to a slot opening at the back of the system chassis. The
USB connectors comply with USB 2.0 specification that supports up to 480 Mbps
connection speed.
4. USB 3.2 Gen 1 connector (U31G1_34; U31G1_5)
This connector allows you to connect a USB 3.2 Gen 1 module for additional USB 3.2
Gen 1 ports on the front panel. The USB 3.2 Gen 1 connector provides data transfer
speeds of up to 10 Gb/s. The Type-A connector allows you to directly connect a USB
flash drive.
The USB port module is purchased separately.
ASUS RS700A-E11 Series 4-13
5. Chassis Intrusion (2-pin INTRUSION1)
These leads are for the intrusion detection feature for chassis with intrusion sensor or
microswitch. When you remove any chassis component, the sensor triggers and sends
a high level signal to these leads to record a chassis intrusion event. The default setting
is to short the CHASSIS# and the GND pin by a jumper cap to disable the function.
6. Serial port connector (10-1 pin COM1)
This connector is for a serial (COM) port. Connect the serial port module cable to this
connector, then install the module to a slot opening at the back of the system chassis.
The COM module is purchased separately.
Chapter 4: Motherboard Information
4-14
7. System fan connectors (6-pin FRNT_FAN1-8; 6-pin REAR_FAN1-2)
The fan connectors support cooling fans of 0.8A–1.0A (12 W max.) or a total of 6.4
A–8.0 A (96 W max.) at +12V. Connect the fan cables to the fan connectors on the
motherboard, making sure that the black wire of each cable matches the ground pin of
the connector.
DO NOT forget to connect the fan cables to the fan connectors. Insufficient air flow inside
the system may damage the motherboard components. These are not jumpers! DO NOT
place jumper caps on the fan connectors!
ASUS RS700A-E11 Series 4-15
8. TPM connector (14-1 pin TPM1)
This connector supports a Trusted Platform Module (TPM) system, which can securely
store keys, digital certificates, passwords, and data. A TPM system also helps enhance
network security, protects digital identities, and ensures platform integrity.
9. M.2 (NGFF) card connector (NGFF1-2)
These connectors allow you to install M.2 devices.
This connector supports type 2242 / 2260 / 2280 / 22110 devices on both PCI-E and SATA
interface.
The M.2 (NGFF) device is purchased separately
Chapter 4: Motherboard Information
4-16
10. Back panel power connector (4-pin BPPWR1, BPPWR4; 8-pin BPPWR2-3)
These connectors are for the power supply plugs that connects to the back panel. The
power supply plugs are designed to fit these connectors in only one orientation. Find
the proper orientation and push down firmly until the connectors completely fit.
DO NOT connect VGA cards to these connectors. Doing so may cause system boot errors
and permanent damage to your motherboard or device.
11. VGA power connectors (8-pin VGAPWR1-4)
These connectors are for the power supply plugs that connects to the VGA card. The
power supply plugs are designed to fit these connectors in only one orientation. Find
the proper orientation and push down firmly until the connectors completely fit.
DO NOT connect the back panel to these connectors. Doing so may cause system boot
errors and permanent damage to your motherboard or device.
ASUS RS700A-E11 Series 4-17
12. VGA connector (16-pin VGA_HDR1)
This connector supports the VGA High Dynamic-Range interface.
13. Micro SD card slot (MSD1)
Your motherboard supports SD Memory Card v2.00 (SDHC) / v3.00 (SDXC).
Some memory cards may not be compatible with your motherboard. Ensure that you use
only compatible memory cards to prevent loss of data, damage to your device, or memory
card, or both.
Disconnect all power (including redundant PSUs) from the existing system before you add
or remove a Memory Card, then reboot the system to access the Memory Card.
Chapter 4: Motherboard Information
4-18
14. System panel connector (10-1 pin PANEL1; 14-1 pin PANEL2)
This connector supports several chassis-mounted functions.
• System power LED (POWERLED)
This 2-pin connector is for the system power LED. Connect the chassis power LED
cable to this connector. The system power LED lights up when you turn on the system
power, and blinks when the system is in sleep mode.
• Message LED (2-pin MLED)
This 2-pin connector is for the message LED cable that connects to the front message
LED. The message LED is controlled by the BMC to indicate an abnormal event
occurrence.
• Locator LED connector (BMCLOCLED, LOCLED)
This connector allows you to connect the Locator LED. The Location LED helps visually
locate and identify the server in error on a server rack.
• Power Button/Soft-off Button connector (PWRBTN)
The 3-1 pin connector allows you to connect the system power button. Press the power
button to power up the system, or put the system into sleep or soft-off mode (depending
on the operating system settings).
• LAN activity LED connector (LAN1_LED, LAN2_LED, LAN3_LED, LAN4_LED)
This 2-pin connector allows you to connect the Gigabit LAN Activity LED.
• Reset button connector (RESET)
This connector allows you to connect the chassis-mounted reset button. Press the
reset button to reboot the system.
• TR1 Sensor connector (TR1 SENSOR)
This connector allows detection of the environmental temperature of the front panel.
ASUS RS700A-E11 Series 4-19
15. Storage device activity LED connector (4-pin HDLED1)
This LED connector is for the storage add-on card cable connected to the SATA or
SAS add-on card. The read or write activities of any device connected to the SATA or
SAS add-on card causes the front panel LED to light up.
• Locator button connector (BMCLOCBTN#)
This connector allows you to connect the Locator button. Press the button to light up
the Locator LED.
• Storage Device Activity LED connector (HDLED)
This connector allows you to connect the Storage Device Activity LED. The Storage
Device Activity LED lights up or blinks when data is read from or written to the storage
device or storage device add-on card.
Chapter 4: Motherboard Information
4-20
16. I2C connector (10-1 pin BP_I2C1)
This connector is used for the AMD NVME Hot plug function and for the NVME
temperature read function.
17. BMC Debug UART connector (3-pin BMC_DEBUGUART1)
This connector is used for reading the BMC UART Debug log.
ASUS RS700A-E11 Series 4-21
18. CPLD JTAG connector (6-pin CPLD_JTAG1)
This connector is used for burning the CPLD JTAG.
19. Liquid connector (12-1 pin LIQUID_CONN1)
This connector is used for detecting the pump speed of the water cooling system.
Chapter 4: Motherboard Information
4-22
20. SLMPCIE SGPIO connector (6-1 pin SLMPCIE5_SGPIO1)
This connector is the SGPIO header for controlling the HDD LED function.
5
BIOS Setup
This chapter tells how to change the system settings through
the BIOS Setup menus. Detailed descriptions of the BIOS
parameters are also provided.
Chapter 5: BIOS Setup
5-2 Chapter 5: BIOS Setup
5.1 Managing and updating your BIOS
The following utilities allow you to manage and update the motherboard Basic Input/Output
System (BIOS) setup:
1. ASUS CrashFree BIOS 3
To recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or
gets corrupted.
2. ASUS EzFlash
Updates the BIOS using a USB flash disk.
3. BUPDATER
Updates the BIOS in DOS mode using a bootable USB flash disk drive.
Refer to the corresponding sections for details on these utilities.
Recovering the BIOS from a USB flash drive
To recover the BIOS from a USB flash drive:
1. Insert the USB flash drive with the original or updated BIOS file to one USB port on the
system.
2. The utility will automatically recover the BIOS. It resets the system when the BIOS
recovery finished.
DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause
system boot failure!
The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the
ASUS website at www.asus.com to download the latest BIOS file.
Save a copy of the original motherboard BIOS file to a bootable USB flash disk drive in
case you need to restore the BIOS in the future. Copy the original motherboard BIOS using
the BUPDATER utility.
5.1.1 ASUS CrashFree BIOS 3 utility
The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file
when it fails or gets corrupted during the updating process. You can update a corrupted BIOS
file using a USB flash drive that contains the updated BIOS file.
Prepare a USB flash drive containing the updated motherboard BIOS before using this
utility.
5-3
ASUS RS700A-E11 Series
3. Press Left arrow key to switch to the Drive field.
4. Press the Up/Down arrow keys to find the USB flash disk that contains the latest BIOS,
then press <Enter>.
5. Press Right arrow key to switch to the Folder Info field.
6. Press the Up/Down arrow keys to find the BIOS file, and then press <Enter> to perform
the BIOS update process. Reboot the system when the update process is done.
• This function can support devices such as a USB flash disk with FAT 32/16 format and
single partition only.
• DO NOT shut down or reset the system while updating the BIOS to prevent system
boot failure!
Ensure to load the BIOS default settings to ensure system compatibility and stability. Press
<F5> and select Yes to load the BIOS default settings.
5.1.2 ASUS EZ Flash Utility
The ASUS EZ Flash Utility feature allows you to update the BIOS without having to use a
DOS-based utility.
Before you start using this utility, download the latest BIOS from the ASUS website at
www.asus.com.
To update the BIOS using EZ Flash Utility:
1. Insert the USB flash disk that contains the latest BIOS file into the USB port.
2. Enter the BIOS setup program. Go to the Tool menu then select Start ASUS EzFlash.
Press <Enter>.
Current Platform
Platform : KMPP-D32
Version : 0215
Build date: 12/13/2020
New Platform
Platform : KMPP-D32
Version : 0217
Build date: 01/02/2021
ASUS Tek. EzFlash Utility
FS0
FS1
[Up/Down/Left/Right]:Switch [Enter]:Choose [q]:Exit
5-4 Chapter 5: BIOS Setup
5.1.3 BUPDATER utility
The succeeding BIOS screens are for reference only. The actual BIOS screen displays
may not be the same as shown.
The BUPDATER utility allows you to update the BIOS file in the DOS environment using a
bootable USB flash disk drive with the updated BIOS file.
Updating the BIOS file
To update the BIOS file using the BUPDATER utility:
1. Visit the ASUS website at www.asus.com and download the latest BIOS file for the
motherboard. Save the BIOS file to a bootable USB flash disk drive.
2. Copy the BUPDATER utility (BUPDATER.exe) from the ASUS support website at
www.asus.com/support to the bootable USB flash disk drive you created earlier.
3. Boot the system in DOS mode, then at the prompt, type:
BUPDATER /i[filename].CAP
where [filename] is the latest or the original BIOS file on the bootable USB flash disk
drive, then press <Enter>.
A:\>BUPDATER /i[file name].CAP
5-5
ASUS RS700A-E11 Series
4. The utility verifies the file, then starts updating the BIOS file.
DO NOT shut down or reset the system while updating the BIOS to prevent system boot
failure!
5. The utility returns to the DOS prompt after the BIOS update process is completed.
Reboot the system from the hard disk drive.
The BIOS update is finished! Please restart your system.
C:\>
Current Platform
Platform : KMPP-D32
Version : 0215
Build date: 12/13/2020
New Platform
Platform : KMPP-D32
Version : 0217
Build date: 01/02/2021
ASUS Tek. EzFlash Utility
Start Programming Flash. DO NOT SHUTDOWN THE SYSTEM!!!
Write
75%
5-6 Chapter 5: BIOS Setup
5.2 BIOS setup program
This motherboard supports a programmable firmware chip that you can update using the
provided utility described in section 5.1 Managing and updating your BIOS.
Use the BIOS Setup program when you are installing a motherboard, reconfiguring your
system, or prompted to “Run Setup.” This section explains how to configure your system
using this utility.
Even if you are not prompted to use the Setup program, you can change the configuration of
your computer in the future. For example, you can enable the security password feature or
change the power management settings. This requires you to reconfigure your system using
the BIOS Setup program so that the computer can recognize these changes and record them
in the CMOS RAM of the firmware chip.
The firmware chip on the motherboard stores the Setup utility. When you start up the
computer, the system provides you with the opportunity to run this program. Press <Del>
during the Power-On Self-Test (POST) to enter the Setup utility; otherwise, POST continues
with its test routines.
If you wish to enter Setup after POST, restart the system by pressing <Ctrl>+<Alt>+<Delete>,
or by pressing the reset button on the system chassis. You can also restart by turning the
system off and then back on. Do this last option only if the first two failed.
The Setup program is designed to make it as easy to use as possible. Being a menu-driven
program, it lets you scroll through the various sub-menus and make your selections from the
available options using the navigation keys.
• The default BIOS settings for this motherboard apply for most conditions to ensure
optimum performance. If the system becomes unstable after changing any BIOS
settings, load the default settings to ensure system compatibility and stability. Press
<F5> and select Yes to load the BIOS default settings.
• The BIOS setup screens shown in this section are for reference purposes only, and
may not exactly match what you see on your screen.
• Visit the ASUS website (www.asus.com) to download the latest BIOS file for this
motherboard.
5-7
ASUS RS700A-E11 Series
5.2.2 Menu bar
The menu bar on top of the screen has the following main items:
Main For changing the basic system configuration
Performance Tuning For changing the performance settings
Advanced For changing the advanced system settings
Chipset For changing the chipset settings
Security For changing the security settings
Boot For changing the system boot configuration
Tool For configuring options for special functions
Save & Exit For selecting the exit options
AMD CBS For configuring AMD CBS settings
Event Logs For changing the event log settings
Server Mgmt For changing the Server Mgmt settings
To select an item on the menu bar, press the right or left arrow key on the keyboard until the
desired item is highlighted.
5.2.1 BIOS menu screen
Navigation keys
General help
Menu bar Configuration fieldsMenu items
5-8 Chapter 5: BIOS Setup
5.2.3 Menu items
The highlighted item on the menu bar displays the specific items for that menu. For example,
selecting Main shows the Main menu items.
The other items (such as Advanced) on the menu bar have their respective menu items.
5.2.4 Submenu items
A solid triangle before each item on any menu screen means that the item has a submenu.
To display the submenu, select the item then press <Enter>.
5.2.5 Navigation keys
At the bottom right corner of a menu screen are the navigation keys for the BIOS setup
program. Use the navigation keys to select items in the menu and change the settings.
5.2.6 General help
At the top right corner of the menu screen is a brief description of the selected item.
5.2.7 Configuration fields
These fields show the values for the menu items. If an item is user-configurable, you can
change the value of the field opposite the item. You cannot select an item that is not user-
configurable.
A configurable field is enclosed in brackets, and is highlighted when selected. To change the
value of a field, select it and press <Enter> to display a list of options.
5.2.8 Pop-up window
Select a menu item and press <Enter> to display a pop-up window with the configuration
options for that item.
5.2.9 Scroll bar
A scroll bar appears on the right side of a menu screen when there are items that do not fit on
the screen. Press the Up / Down arrow keys or <Page Up> / <Page Down> keys to display
the other items on the screen.
5-9
ASUS RS700A-E11 Series
5.3 Main menu
When you enter the BIOS Setup program, the Main menu screen appears. The Main menu
provides you an overview of the basic system information, and allows you to set the system
date, time, and language settings.
5.3.1 System Language [English]
Allows you to select the system default language.
5.3.2 System Date [Day xx/xx/xxxx]
Allows you to set the system date.
5.3.3 System Time [xx:xx:xx]
Allows you to set the system time.
5-10 Chapter 5: BIOS Setup
5.4 Performance Tuning menu
The Performance Tuning menu items allow you to change performance related settings for
different scenarios.
Optimized Performance Setting [Default]
Allows you to select performance settings for different scenarios.
[Default] Default settings.
[By Benchmark] Optimize for different kinds of benchmarks. Select this option, then select a
benchmark type from the >> list.
[By Workload] Optimize for different kinds of workloads. Select this option, then select a
workload type from the >> list.
Configuration options:
[Peak Frequency Optimized] - Applies settings with performance and
power consumption balance. Recommended for users that need higher
performance.
[Latency Optimized] - Applies settings with low latency results.
Recommended for latency-sensitive users.
[Power Efficient Optimized] - Applies settings with power efficiency.
Recommended for general users.
[HPC] - Applies settings with optimized compute capability. Recommend
for traditional HPC applications.
Core Optimizer and Engine Boost appear only when you set Optimized Performance
Setting to [Default] or [By Benchmark].
Core Optimizer [Disabled]
Enable this item to keep the processor operating at the turbo frequency.
Configuration options: [Disabled] [Enabled]
Linux support may vary by version of the OS.
Engine Boost [Disabled]
Enable this item to boost the CPU's frequency.
Configuration options: [Disabled] [Level1] [Level2] [Level3(Max)]
5-11
ASUS RS700A-E11 Series
Overclocking [Disabled]
Enable this item to increase the CPU’s clock. Please use an external PCIe storage controller
for your hard drives when enabling this feature.
Configuration options: [Disabled] [Enabled]
Operate with an ambient temperature of 25oC or lower for optimized performance.
Please note that overclocking might cause component damage or system crashes, which
may reduce the lifespan of the system and the CPU. Use this tool at your own risk.
5.5 Advanced menu
The Advanced menu items allow you to change the settings for the CPU and other system
devices.
Take caution when changing the settings of the Advanced menu items. Incorrect field
values can cause the system to malfunction.
BIOS RedFish Support [Disabled]
Allows you to enable or disable the BIOS support for RedFish.
Configuration options: [Disabled] [Enabled]
5-12 Chapter 5: BIOS Setup
5.5.1 Trusted Computing
5.5.2 PSP Firmware Versions
This page displays the PSP firmware versions.
Configuration
Security Device Support [Enable]
Allows you to enable or disable the BIOS support for security device. O.S. will not show
Security Device. TCG EFI protocol and INT1A interface will not be available.
Configuration options: [Disable] [Enable]
Disable Block Sid [Disabled]
Allows you to override to allow SID authentication in TCG Storage device.
Configuration options: [Disable] [Enable]
5.5.3 APM Configuration
Allows you to configure the Advance Power Management (APM) settings.
Restore AC Power Loss [Last State]
[Power Off] The system goes into off state after an AC power loss.
[Power On] The system will reboot after an AC power loss.
[Last State] The system goes into either off or on state, whatever the system state was
before the AC power loss.
5-13
ASUS RS700A-E11 Series
Onboard I350 LAN Configuration
Intel I350 LAN1
LAN Enable [JumperState]
Allows you to enable or disable the Intel LAN.
Configuration options: [Disabled] [JumperState]
The following item appears only when LAN Enable is set to [JumperState].
ROM Type [PXE]
Allows you to select the Intel LAN ROM type.
Configuration options: [Disabled] [PXE] [iSCSI]
Intel I350 LAN2
LAN Enable [JumperState]
Allows you to enable or disable the Intel LAN.
Configuration options: [Disabled] [Enabled]
The following item appears only when LAN Enable is set to [JumperState].
ROM Type [Disabled]
Allows you to select the Intel LAN ROM type.
Configuration options: [Disabled] [PXE] [iSCSI]
5.5.4 Onboard LAN Configuration
Power On By PCI-E/PCI [Disabled]
[Disabled] Disables the PCIE devices to generate a wake event.
[Enabled] Enables the PCIE devices to generate a wake event.
Power On By RTC [Disabled]
[Disabled] Disables RTC to generate a wake event.
[Enabled] When set to [Enabled], the items RTC Alarm Date (Days) and
Hour/Minute/Second will become user-configurable with set values.
5-14 Chapter 5: BIOS Setup
5.5.5 Serial Port Console Redirection
COM1
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Configuration options: [Disabled] [Enabled]
The following item appears only when Console Redirection is set to [Enabled].
Console Redirection Settings
These items become configurable only when you enable the Console Redirection
item. The settings specify how the host computer and the remote computer (which the
user is using) will exchange data. Both computers should have the same or compatible
settings.
Terminal Type [ANSI]
Allows you to set the terminal type.
[VT100] ASCII char set.
[VT100+] Extends VT100 to support color, function keys, etc.
[VT-UTF8] Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.
[ANSI] Extended ASCII char set.
Bits per second [115200]
Selects serial port transmission speed. The speed must be matched on the other side.
Long or noisy lines may require lower speeds.
Configuration options: [9600] [19200] [38400] [57600] [115200]
Data Bits [8]
Configuration options: [7] [8]
5-15
ASUS RS700A-E11 Series
Parity [None]
A parity bit can be sent with the data bits to detect some transmission errors. [Mark]
and [Space] parity do not allow for error detection.
[None] None
[Even] parity bit is 0 if the num of 1’s in the data bits is even
[Odd] parity bit is 0 if num of 1’s in the data bits is odd
[Mark] parity bit is always 1
[Space] parity bit is always 0
Stop Bits [1]
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit.
Configuration options: [1] [2]
Flow Control [None]
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a “stop” signal can be sent to stop the data flow. Once the
buffers are empty, a “start” signal can be sent to re-start the flow. Hardware flow
control uses two wires to send start/stop signals.
Configuration options: [None] [Hardware RTS/CTS]
VT -UTF8 Combo Key Support [Enabled]
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100
terminals.
Configuration options: [Disabled] [Enabled]
Recorder Mode [Disabled]
With this mode enabled only text will be sent. This is to capture Terminal data.
Configuration options: [Disabled] [Enabled]
Resolution 100x31 [Enabled]
This allows you enable or disable extended terminal resolution.
Configuration options: [Disabled] [Enabled]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty.
Configuration options: [VT100] [LINUX] [XTERMR6] [SCO] [ESCN] [VT400]
COM2
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Configuration options: [Disabled] [Enabled]
5-16 Chapter 5: BIOS Setup
The following item appears only when Console Redirection is set to [Enabled].
Console Redirection Settings
These items become configurable only when you enable the Console Redirection
item. The settings specify how the host computer and the remote computer (which the
user is using) will exchange data. Both computers should have the same or compatible
settings.
Terminal Type [ANSI]
Allows you to set the terminal type.
[VT100] ASCII char set.
[VT100+] Extends VT100 to support color, function keys, etc.
[VT-UTF8] Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.
[ANSI] Extended ASCII char set.
Bits per second [57600]
Selects serial port transmission speed. The speed must be matched on the other side.
Long or noisy lines may require lower speeds.
Configuration options: [9600] [19200] [38400] [57600] [115200]
Data Bits [8]
Configuration options: [7] [8]
Parity [None]
A parity bit can be sent with the data bits to detect some transmission errors. [Mark]
and [Space] parity do not allow for error detection.
[None] None
[Even] parity bit is 0 if the num of 1’s in the data bits is even
[Odd] parity bit is 0 if num of 1’s in the data bits is odd
[Mark] parity bit is always 1
[Space] parity bit is always 0
Stop Bits [1]
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit.
Configuration options: [1] [2]
Flow Control [None]
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a “stop” signal can be sent to stop the data flow. Once the
buffers are empty, a “start” signal can be sent to re-start the flow. Hardware flow
control uses two wires to send start/stop signals.
Configuration options: [None] [Hardware RTS/CTS]
5-17
ASUS RS700A-E11 Series
VT -UTF8 Combo Key Support [Enabled]
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100
terminals.
Configuration options: [Disabled] [Enabled]
Recorder Mode [Disabled]
With this mode enabled only text will be sent. This is to capture Terminal data.
Configuration options: [Disabled] [Enabled]
Resolution 100x31 [Enabled]
This allows you enable or disable extended terminal resolution.
Configuration options: [Disabled] [Enabled]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty.
Configuration options: [VT100] [LINUX] [XTERMR6] [SCO] [ESCN] [VT400]
Legacy Console Redirection Settings
Legacy Console Redirection Port [COM1]
Allows you to select a COM port to display redirection of Legacy OS and Legacy
OPROM Messages.
Configuration options: [COM1] [COM2]
Resolution [80x24]
This allows you to set the number of rows and columns supported on the Legacy OS.
Configuration options: [80x24] [80x25]
Redirection After POST [Always Enable]
This setting allows you to specify if Bootloader is selected than Legacy console
redirection.
Configuration options: [Always Enable] [Bootloader]
Serial Port for Out-of-Band Management/
Windows Emergency Management Services (EMS)
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Configuration options: [Disabled] [Enabled]
The following item appears only when Console Redirection is set to [Enabled].
Console Redirection Settings
Out-of-Band Mgmt Port [COM1]
Microsoft Windows Emergency Management Services (EMS) allow for remote
management of a Windows Server OS through a serial port.
Configuration options: [COM1] [COM2]
5-18 Chapter 5: BIOS Setup
5.5.6 CPU Configuration
This page displays the CPU node information.
SVM Mode [Enable]
This item allows you enable or disable CPU Virtualization.
Configuration options: [Disabled] [Enable]
SMEE Mode [Enable]
This item allows you to enable or disable control secure memory encryption.
Configuration options: [Disabled] [Enable]
Node 0 Information
This item allows you to view memory information related to Node 0.
Node 1 Information
This item allows you to view memory information related to Node 1.
Terminal Type [VT-UTF8]
Microsoft Windows Emergency Management Services (EMS) allow for remote
management of a Windows Server OS through a serial port.
Configuration options: [VT100] [VT100+] [VT-UTF8] [ANSI]
Bits per second [115200]
Microsoft Windows Emergency Management Services (EMS) allow for remote
management of a Windows Server OS through a serial port.
Configuration options: [9600] [19200] [57600] [115200]
Flow Control [None]
Microsoft Windows Emergency Management Services (EMS) allow for remote
management of a Windows Server OS through a serial port.
Configuration options: [None] [Hardware RTS/CTS] [Software Xon/Xoff]
5-19
ASUS RS700A-E11 Series
5.5.7 PCI Subsystem Settings
Allows you to configure PCI, PCI-X, and PCI Express Settings.
VGA Palette Snoop [Disabled]
This option enables or disables VGA Palette Registers Snooping.
Configuration options: [Disabled] [Enabled]
Load RT32 Image [Enabled]
This option enables or disables RT32 Image Loading.
Configuration options: [Disabled] [Enabled]
Above 4G Decoding [Enabled]
Allows you to enable or disable 64-bit capable devices to be decoded in above 4G address
space. It only works if the system supports 64-bit PCI decoding.
Configuration options: [Disabled] [Enabled]
The following items appear only when Above 4G Decoding is set to [Enabled].
First VGA 4G Decode [Auto]
[Auto] Auto
[Above_4G] Force First VGA to above 4G
LAN Device 4G Decode [Below_4G]
LAN Device 4G Decode.
Configuration options: [Above_4G] [Below_4G]
SR-IOV Support [Enabled]
This option enables or disables Single Root IO Virtualization Support if the system has SR-
IOV capable PCIe devices.
Configuration options: [Disabled] [Enabled]
BME DMA Mitigation [Disabled]
This allows you to enable or disable re-enabling Bus Master Attribute disabled during Pci
enumeration for PCI Bridges after SMM locked.
Configuration options: [Disabled] [Enabled]
5-20 Chapter 5: BIOS Setup
OnBrd/Ext VGA Select [Auto]
This allows you to select between onboard or external VGA support.
Configuration options: [Auto] [Onboard] [External]
PCIE OPROM Slot Options
5.5.8 USB Configuration
Legacy USB Support [Enabled]
Allows you to enable or disable Legacy USB device support.
Configuration options: [Enabled] [Disabled] [Auto]
XHCI Hand-off [Enabled]
Allows you to enable or disable workaround for OSes without XHCI hand-off support. The
XHCI ownership change should be claimed by XHCI driver.
Configuration options: [Enabled] [Disabled]
USB Mass Storage Driver Support [Enabled]
Allows you to enable or disable the USB Mass Storage driver support.
Configuration options: [Disabled] [Enabled]
Port 60/64 Emulation [Enabled]
Allows you to enable or disable I/O port 60h/64h emulation support. This should be enabled
for the complete keyboard legacy support for non-USB aware OSes.
Configuration options: [Disabled] [Enabled]
USB hardware delays and time-outs
USB transfer time-out [20 sec]
Allows you to select time-out value for Control, Bulk, and Interrupt transfers.
Configuration options: [1 sec] [5 sec] [10 sec] [20 sec]
5-21
ASUS RS700A-E11 Series
Device reset time-out [20 sec]
Allows you to select time-out value for USB mass storage device Start Unit command.
Configuration options: [10 sec] [20 sec] [30 sec] [40 sec]
Device power-up delay [Auto]
Allows you to select maximum time the device will take before it properly reports itself to the
Host Controller.
Configuration options: [Auto] [Manual]
The following item appears only when Device power-up delay is set to [Manual].
Device power-up delay in seconds [5]
Allows you to set the device power-up delay in seconds. Use the <+> or <-> to adjust
the value. The values range from 1 to 40.
Mass Storage Devices
Allows you to select the mass storage device emulation type for devices connected.
Configuration options: [Auto] [Floppy] [Forced FDD] [Hard Disk] [CD-ROM]
Network stack [Disabled]
Enables or disables the network stack feature.
Configuration options: [Disable] [Enable]
The following item appears only when Network stack is set to [Enabled].
Ipv4 PXE Support [Disabled]
Enables or disables the Ipv4 PXE Boot Support. If disabled, Ipv4 PXE boot option will
not be created.
Configuration options: [Disabled] [Enabled]
Ipv4 HTTP Support [Disabled]
Enables or disables the Ipv4 HTTP Boot Support. If disabled, Ipv4 HTTP boot option
will not be created.
Configuration options: [Disabled] [Enabled]
Ipv6 PXE Support [Disabled]
Enables or disables the Ipv6 PXE Boot Support. If disabled, Ipv6 PXE boot option will
not be created.
Configuration options: [Disabled] [Enabled]
5.5.9 Network Stack Configuration
5-22 Chapter 5: BIOS Setup
5.5.10 CSM Configuration
CSM Support [Disabled]
This option allows you to enable or disable CSM Support.
Configuration options: [Disabled] [Enabled]
The following item appears only when CSM Support is set to [Enabled].
GateA20 Active [Upon Request]
This allows you to set the GA20 option.
Configuration options: [Upon Request] [Always]
Option ROM Messages [Force BIOS]
This allows you to set the display mode for option ROM.
Configuration options: [Force BIOS] [Keep Current]
INT19 Trap Response [Immediate]
The BIOS reaction on INT19 trapping by Option ROM.
[Immediate] Execute the trap right away.
[Postponed] Execute the trap during legacy boot.
HDD Connection Order [Adjust]
This option allows you to select the HDD Connection Order. Some OS require HDD
handles to be adjusted, i.e. OS is installed on drive 80h.
Configuration options: [Adjust] [Keep]
Boot Option filter [UEFI and Legacy]
This option allows you to control the Legacy/UEFI ROMs priority.
Configuration options: [UEFI and Legacy] [Legacy only] [UEFI only]
Ipv6 HTTP Support [Disabled]
Enables or disables the Ipv6 HTTP Boot Support. If disabled, Ipv6 HTTP boot option
will not be created.
Configuration options: [Disabled] [Enabled]
PXE boot wait time [0]
Set the wait time to press ESC key to abort the PXE boot. Use the <+> or <-> to adjust
the value. The values range from 0 to 5.
Media detect count [1]
Set the number of times presence of media will be checked. Use the <+> or <-> to
adjust the value. The values range from 1 to 50.
5-23
ASUS RS700A-E11 Series
Network / Storage / Video [Legacy]
This option allows you to control the execution of UEFI and Legacy PXE / Storage /
Video OpROM.
Configuration options: [UEFI] [Legacy]
Other PCI devices [Legacy]
This item determines the OpROM execution policy for devices other than Network,
Storage, or Video.
Configuration options: [UEFI] [Legacy]
Device
The devices and names shown in the NVMe configuration list depends on the connected
devices. If no devices are connected, No NVMe Device Found will be displayed.
Self Test Option [Short]
This option allows you to select either Short or Extended Self Test. Short option will
take couple of minutes, and the extended option will take several minutes to complete.
Configuration options: [Short] [Extended]
Self Test Action [Controller Only Test]
This item allows you to select either to test Controller alone or Controller and
NameSpace. Selecting Controller and Namespace option will take a lot longer to
complete the test.
Configuration options: [Controller Only Test] [Controller and NameSpace Test]
Run Device Self Test
Press <Enter> to perform device self test for the corresponding Option and Action
selected by the user. Pressing the <ESC> key will abort the test. The results shown
below is the most recent result logged in the device.
5.5.11 NVMe Configuration
This page will display the NVMe controller and drive information.
5-24 Chapter 5: BIOS Setup
5.5.12 SATA Configuration
This page will display the SATA controller and drive information.
5.5.13 AMD Mem Configuration Status
The items in this menu display the memory configuration (initialized by ABL) status.
5-25
ASUS RS700A-E11 Series
5.5.14 iSCSI Configuration
Allows you to configure the iSCSi parameters.
5-26 Chapter 5: BIOS Setup
5.6 Chipset menu
The Chipset menu items allow you to change the Chipset settings.
PCIe Link Training Type [1 Step]
This item allows you to select PCIe Link Training in 1 or 2 steps.
Configuration options: [1 Step] [2 Step]
PCIe Compliance Mode [Off]
This item allows you to turn the PCIe Compliance Mode on or off.
North Bridge
Socket 0 Information
This item displays the memory information on Socket 0.
Socket 1 Information
This item displays the memory information on Socket 1.
5-27
ASUS RS700A-E11 Series
5.7 Security menu
This menu allows a new password to be created or a current password to be changed. The
menu also enables or disables the Secure Boot state and lets the user configure the System
Mode state.
Administrator Password
To set an administrator password:
1. Select the Administrator Password item and press <Enter>.
2. From the Create New Password box, key in a password, then press <Enter>.
3. Confirm the password when prompted.
To change an administrator password:
1. Select the Administrator Password item and press <Enter>.
2. From the Enter Current Password box, key in the current password, then press
<Enter>.
3. From the Create New Password box, key in a new password, then press <Enter>.
4. Confirm the password when prompted.
To clear the administrator password, follow the same steps as in changing an administrator
password, but press <Enter> when prompted to create/confirm the password.
5-28 Chapter 5: BIOS Setup
User Password
To set a user password:
1. Select the User Password item and press <Enter>.
2. From the Create New Password box, key in a password, then press <Enter>.
3. Confirm the password when prompted.
To change a user password:
1. Select the User Password item and press <Enter>.
2. From the Enter Current Password box, key in the current password, then press
<Enter>.
3. From the Create New Password box, key in a new password, then press <Enter>.
4. Confirm the password when prompted.
To clear a user password:
1. Select the Clear User Password item and press <Enter>.
2. Select Yes from the Warning message window then press <Enter>.
Secure Boot
This item allows you to customize the Secure Boot settings.
Secure Boot [Disabled]
Secure Boot can be enabled if the system is running in User mode with enrolled platform Key
(EPK) or if the CSM function is disabled.
Configuration options: [Disabled] [Enabled]
Secure Boot Mode [Custom]
Allows you to set the Secure Boot selector.
Configuration options: [Custom] [Standard]
The following items are only available when Secure Boot Mode is set to [Custom].
Restore Factory Keys
This option will force the system to User Mode, and install factory default Secure Boot key
databases.
5-29
ASUS RS700A-E11 Series
Key Management
This item only appears when the item Secure Boot Mode is set to [Custom]. The Key
Management item allows you to modify Secure Boot variables and set Key Management
page.
Factory Key Provision [Disabled]
Allows you to provision factory default Secure Boot keys when the system is in Setup
Mode.
Configuration options: [Disabled] [Enabled]
Restore Factory keys
This item will install all Factory Default keys.
Reset to Setup Mode
This item appears only when you load the default Secure Boot keys. This item allows
you to clear all default Secure Boot keys.
Export Secure Boot Variables
This item will ask you if you want to save all secure boot variables. Select Yes if you
want to save all secure boot variables, otherwise select No.
Enroll Efi Image
This item will allow the image to run in Secure Boot mode.
Configuration options: [Set New] [Append]
Device Guard Ready
Remove ‘UEFI CA’ from DB
Remove Microsoft UEFI CA from Secure Boot DB.
Reset to Setup Mode
This option will delete all Secure Boot key databases from NVRAM.
5-30 Chapter 5: BIOS Setup
Restore DB defaults
Restore DB variable to factory defaults.
Platform Key (PK)
Configuration options: [Details] [Export] [Update] [Delete]
Key Exchange Keys (KEK) / Authorized Signatures (DB) / Forbidden Signatures
(DBX)
Configuration options: [Details] [Export] [Update] [Append] [Delete]
Authorized TimeStamps (DBT) / OsRecovery Signatures
Configuration options: [Update] [Append]
5-31
ASUS RS700A-E11 Series
Setup Prompt Timeout [1]
Allows you to set the number of seconds that the firmware waits before initiating the original
default boot selection. 65535(OxFFFF) means indefinite waiting. Use the <+> or <-> to adjust
the value.
Bootup NumLock State [On]
Allows you to select the power-on state for the NumLock.
Configuration options: [Off] [On]
Quiet Boot [Disabled]
Allows you to enable or disable Quiet Boot option.
Configuration options: [Disabled] [Enabled]
Boot Option Priorities
These items specify the boot device priority sequence from the available devices. The
number of device items that appears on the screen depends on the number of devices
installed in the system.
• To select the boot device during system startup, press <F8> when ASUS Logo
appears.
• To access Windows OS in Safe Mode, please press <F8> after POST.
5.8 Boot menu
The Boot menu items allow you to change the system boot options.
5-32 Chapter 5: BIOS Setup
5.9 Tool menu
The Tool menu items allow you to configure options for special functions. Select an item then
press <Enter> to display the submenu.
IPMI HWM
Allows you to run the IPMI hardware monitor.
Start ASUS EzFlash
Allows you to run ASUS EzFlash BIOS ROM Utility when you press <Enter>. Refer to the
ASUS EzFlash Utility section for details.
POST Report [5 sec]
Allows you to set the desired POST Report waiting time from 1 to 10 seconds.
Configuration options: [1 sec] ~ [10 sec] [Until Press ESC]
5-33
ASUS RS700A-E11 Series
5.10 Save & Exit menu
The Exit menu items allow you to save or discard your changes to the BIOS items.
Pressing <Esc> does not immediately exit this menu. Select one of the options from this
menu or <F10> from the legend bar to exit.
Discard Changes and Exit
Exit system setup without saving any changes.
Save Changes and Reset
Reset system after saving the changes.
Save Changes
Save changes done so far to any of the setup options.
Discard Changes
Discard changes done so far to any of the setup options.
Restore Defaults
Restore/load default values for all the setup options.
Boot Override
These items displays the available devices. The device items that appears on the screen
depends on the number of devices installed in the system. Click an item to start booting from
the selected device.
5-34 Chapter 5: BIOS Setup
5.11 AMD CBS menu
The items in this menu shows the AMD Common BIOS Specifications.
The AMD CBS menu will appear under the Advanced menu for AMD EPIC™ 7003 Series
processors.
5-35
ASUS RS700A-E11 Series
5.11.1 CPU Common Options
Performance
Custom Core Pstates
This option allows you to enable Core Pstates. Read the disclaimer and select I
Accept to continue.
Damage caused by use of your AMD processor outside of specification or in excess of
factory settings are not covered by your system manufacturers warranty.
The following items appear only when [Accept] is selected for Custom Core Pstates.
Custom Pstate0 [Auto]
Configuration options: [Auto] [Custom]
The following items appear only when Custom Pstate0 is set to [Custom].
Pstate0 FID [74]
Specifies the core frequency multiplier. COF = 200MHz 2 FID / DID.
Pstate0 DID [8]
Specifies the core frequency divisor (DID[0] should zero is DID[5:0]>1Ah).
Pstate0 VID [48]
Specifies the core voltage.
Custom Pstate1 [Auto]
Configuration options: [Auto] [Custom] [Disabled]
The following items appear only when Custom Pstate1 is set to [Custom].
Pstate1 FID [64]
Specifies the core frequency multiplier. COF = 200MHz 2 FID / DID.
Pstate1 DID [a]
Specifies the core frequency divisor (DID[0] should zero is DID[5:0]>1Ah).
Pstate1 VID [58]
Specifies the core voltage.
5-36 Chapter 5: BIOS Setup
The following item is only available when Custom Pstate1 is set to [Custom] or [Auto].
Custom Pstate2 [Auto]
Configuration options: [Auto] [Custom] [Disabled]
The following items appear only when Custom Pstate2 is set to [Custom].
Pstate2 FID [5a]
Specifies the core frequency multiplier. COF = 200MHz 2 FID / DID.
Pstate2 DID [c]
Specifies the core frequency divisor (DID[0] should zero is DID[5:0]>1Ah).
Pstate2 VID [68]
Specifies the core voltage.
CCD/Core/Thread Enhancement
This option allows you to enable CCD/Core/Thread Enablement. Read the disclaimer
and select I Accept to continue.
S3 is not supported on systems where cores/threads have been removed/disabled.
The following items appear only when [Accept] is selected for CCD/Core/Thread
Enhancement.
CCD Control [Auto]
Sets the number of CCDs to be used. Once this option has been used
to remove any CCDs, a POWER CYCLE is required in order for future
selections to take effect.
Configuration options: [Auto] [2 CCDs] [3 CCDs] [4 CCDs] [6 CCDs]
Core Control [Auto]
Sets the number of cores to be used. Once this option has been used
to remove any cores, a POWER CYCLE is required in order for future
selections to take effect.
Configuration options: [Auto] [TWO (1 + 1)] [FOUR (2 + 2)] [SIX (3 + 3)]
SMT Control [Auto]
Can be used to disable symmetric multithreading. To re-enable SMT, a
POWER CYCLE is needed after selecting the [Auto] option.
Configuration options: [Auto] [Disable]
S3 is not supported on systems where cores/threads have been removed/disabled.
Prefetcher settings
L1 Stream HW Prefetcher [Auto]
This item allows you to enable or disable L1 Stream HW Prefetcher.
Configuration options: [Disable] [Enable] [Auto]
L2 Stream HW Prefetcher [Auto]
This item allows you to enable or disable L2 Stream HW Prefetcher.
Configuration options: [Disable] [Enable] [Auto]
5-37
ASUS RS700A-E11 Series
Core Watchdog
Core Watchdog Timer Enable [Auto]
This item allows you to enable or disable CPU Watchdog Timer.
Configuration options: [Disable] [Enable] [Auto]
The following items are only available when Core Watchdog Timer Enable is set to
[Enabled].
Core Watchdog Timer Interval [Auto]
Configuration options: [21.461s] [10.730s] [5.364s] [2.681s] [1.340s] [669.41ms]
[334.05ms] [166.37ms] [82.53ms] [40.61ms] [20.970ms] [10.484ms] [5.241ms]
[2.620ms] [1.309ms] [654.08us] [326.4us] [162.56us] [80.64us] [39.68us] [Auto]
Core Watchdog Timer Severity [Auto]
Configuration options: [No Error] [Transparent] [Corrected] [Deferred] [Uncorrected]
[Fatal] [Auto]
Core Performance Boost [Auto]
This option allows you to enable or disable CPB.
Configuration options: [Disabled] [Auto]
Global C-state Control [Auto]
This option allows you to control IO based C-state generation and DF C-states.
Configuration options: [Disabled] [Enabled] [Auto]
SEV ASID Count [Auto]
This field specifies the maximum valid ASID, which affects the maximum system physical
address space. 16TB of physical address space is available for systems that support 253
ASIDs, while 8TB of physical address space is available for systems that support 509 ASIDs.
Configuration options: [253 ASIDs] [509 ASIDs] [Auto]
SEV-ES ASID Space Limit Control [Auto]
Configuration options: [Auto] [Manual]
The following item appears only when SEV-ES ASID Space Limit Control is set to
[Manual].
SEV-ES ASID Space Limit [1]
SEV Vms using ASIDs below the SEV-ES ASID Space Limit must enable the SEV-ES
feature. ASIDs from SEV-ES ASID Space Limit to (SEV ASID Count + 1) can only be
used with SEV VMs. If this field is set to (SEV ASID Count + 1), all ASIDs are forced to
be SEV-ES ASIDs. Hence, the valid values for this field is 1 - (SEV ASID Count + 1).
Configuration options: [1] – [520]
Local APIC Mode [Auto]
Configuration options: [XAPIC] [X2APIC] [Auto]
RdRand [Auto]
This option allows you to disable RdRand instruction.
Configuration options: [Auto] [Enable] [Disable]
5-38 Chapter 5: BIOS Setup
Scrubber
DRAM scrub time [Auto]
This item allows you to set a number of hours to scrub memory.
Configuration options: [Disabled] [1 hour] [4 hours] [8 hours] [16 hours] [24 hours] [48
hours] [Auto]
Poison scrubber control [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
Redirect scrubber control [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
Redirect scrubber limit [Auto]
Configuration options: [2] [4] [8] [Infinite] [Auto]
Periodic Directory Rinse [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
Memory Addressing
NUMA nodes per socket [Auto]
Specifies the number of desired NUMA nodes per socket. Zero will attempt to
interleave the two sockets together.
Configuration options: [NPS0] [NPS1] [NPS2] [NPS4] [Auto]
Memory interleaving [Auto]
This items allows for disabling memory interleaving. Note that NUMA nodes per socket
will be honored regardless of this setting.
Configuration options: [Disabled] [Auto]
Memory interleaving size [Auto]
This item controls the memory interleaving size. The valid values are AUTO, 256 bytes,
512 bytes, 1 Kbytes, or 2 Kbytes. This also determines the starting address of the
interleave (bit 8, 9, 10, or 11).
Configuration options: [256 Bytes] [512 Bytes] [1 KB] [2 KB] [Auto]
5.11.2 DF Common Options
5-39
ASUS RS700A-E11 Series
1TB remap [Auto]
Attempt to remap DRAM out of the space just below the 1TB boundary. The ability to
remap depends on DRAM configuration, NPS, and interleaving selection, and may not
always be possible.
Configuration options: [Do not remap] [Attempt to remap] [Auto]
DRAM map inversion [Auto]
Inverting the map will cause the highest memory channels to get assigned the lowest
addresses in the system.
Configuration options: [Disabled] [Enabled] [Auto]
Location of private memory regions [Auto]
Controls whether or not the private memory regions (PSP, SMU, and CC6) are at the
top of DRAM or distributed. Note that distributed requires memory on all dies. Note that
it will always be at the top of DRAM id some dies don’t have memory regardless of this
option’s setting.
Configuration options: [Distributed] [Consolidated] [Auto]
Disable DF to external IP SyncFloodPropagation [Auto]
This item allows you to disable SyncFlood to UMC & downstream slaves.
Configuration options: [Sync flood disabled] [Sync flood enabled] [Auto]
Disable DF sync flood propagation [Auto]
Configuration options: [Sync flood disabled] [Sync flood enabled] [Auto]
Freeze DF module queues on error [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
CC6 memory region encryption [Auto]
This item allows you to control whether or not the CC6 save/restore memory is encrypted.
Configuration options: [Disabled] [Enabled] [Auto]
System probe filter [Auto]
This item allows you to enable or disable the probe filter. This has no effect on parts where
the probe filter is fuse disabled.
Configuration options: [Disabled] [Enabled] [Auto]
Memory Clear [Auto]
When this item is set to [Disabled], BIOS does not implement MemClear after memory
training (only if non-ECC DIMMs are used).
Configuration options: [Disabled] [Enabled] [Auto]
PSP error injection support [False]
Configuration options: [False] [True]
5-40 Chapter 5: BIOS Setup
5.11.3 UMC Common Option
DDR4 Common Options
DRAM Timing Configuration
This item allows you to enable DRAM timing configuration.
Damage caused by use of your AMD processor outside of specification or in excess of
factory settings are not covered by your system manufacturers warranty.
The following items appear only when [Accept] is selected for DRAM Timing
Configuration.
Overclock [Auto]
Configuration options: [Auto] [Enabled]
The following items appear only when Overclock is set to [Enabled].
Memory Clock Speed [Auto]
Specifies the memory clock frequency.
Configuration options: [Auto] [667MHz] [800MHz] [933MHz] [1067MHz]
[1200MHz] [1333MHz] [1467MHz] [1600MHz]
Tcl [Auto]
Specifies the CAS latency.
Configuration options: [Auto] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk]
[0Dh Clk] [0Eh Clk] [0Fh Clk] [10h Clk] [11h Clk] [12h Clk] [13h Clk] [14h
Clk] [15h Clk] [16h Clk] [17h Clk] [18h Clk] [19h Clk] [1Ah Clk] [1Bh Clk]
[1Ch Clk] [1Dh Clk] [1Eh Clk] [1Fh Clk] [20h Clk] [21h Clk]
Trcdrd [Auto]
Specifies the RAS# Active to CAS# Read Delay Time.
Configuration options: [Auto] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk]
[0Dh Clk] [0Eh Clk] [0Fh Clk] [10h Clk] [11h Clk] [12h Clk] [13h Clk] [14h
Clk] [15h Clk] [16h Clk] [17h Clk] [18h Clk] [19h Clk] [1Ah Clk] [1Bh Clk]
Trcdwr [Auto]
Specifies the RAS# Active to CAS# Write Delay Time.
Configuration options: [Auto] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk]
[0Dh Clk] [0Eh Clk] [0Fh Clk] [10h Clk] [11h Clk] [12h Clk] [13h Clk] [14h
Clk] [15h Clk] [16h Clk] [17h Clk] [18h Clk] [19h Clk] [1Ah Clk] [1Bh Clk]
5-41
ASUS RS700A-E11 Series
Trp [Auto]
Specifies the Row Precharge Delay Time.
Configuration options: [Auto] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk]
[0Dh Clk] [0Eh Clk] [0Fh Clk] [10h Clk] [11h Clk] [12h Clk] [13h Clk] [14h
Clk] [15h Clk] [16h Clk] [17h Clk] [18h Clk] [19h Clk] [1Ah Clk] [1Bh Clk]
Tras [Auto]
Specifies the Active to Precharge Delay Time.
Configuration options: [Auto] [15h Clk] [16h Clk] [17h Clk] [18h Clk] [19h
Clk] [1Ah Clk] [1Bh Clk] [1Ch Clk] [1Dh Clk] [1Eh Clk] [1Fh Clk] [20h Clk]
[21h Clk] [22h Clk] [23h Clk] [24h Clk] [25h Clk] [26h Clk] [27h Clk] [28h
Clk] [29h Clk] [2Ah Clk] [2Bh Clk] [2Ch Clk] [2Dh Clk] [2Eh Clk] [2Fh Clk]
[30h Clk] [31h Clk] [32h Clk] [33h Clk] [34h Clk] [35h Clk] [36h Clk] [37h
Clk] [38h Clk] [39h Clk] [3Ah Clk]
Trc Ctrl [Auto]
Specifies Trc.
Configuration options: [Auto] [Manual]
The following item appears only when Trc Ctrl is set to [Manual].
Trc [39]
Specifies Active to Active/Refresh Delay Time. Valid values 87h-1Dh.
TrrdS [Auto]
Specifies the Activate to Activate Delay Time, different back group
(tRRD_S).
Configuration options: [Auto] [4 Clk] [5 Clk] [6 Clk] [7 Clk] [8 Clk] [9 Clk]
[0Ah Clk] [0Bh Clk] [0Ch Clk]
TrrdL [Auto]
Specifies the Activate to Activate Delay Time, same back group (tRRD_L).
Configuration options: [Auto] [4 Clk] [5 Clk] [6 Clk] [7 Clk] [8 Clk] [9 Clk]
[0Ah Clk] [0Bh Clk] [0Ch Clk]
Tfaw Ctrl [Auto]
Specifies Tfaw.
Configuration options: [Auto] [Manual]
The following item appears only when Tfaw Ctrl is set to [Manual].
Tfaw [1a]
Specifies the Four Activate Window Time. Valid values 36h-6h.
TwtrS [Auto]
Specifies the Minimum Write to Read Time, different bank group.
Configuration options: [Auto] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7 Clk] [8
Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk]
TwtrL [Auto]
Specifies the Minimum Write to Read Time, same bank group.
Configuration options: [Auto] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7 Clk] [8
Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk]
5-42 Chapter 5: BIOS Setup
Twr Ctrl [Auto]
Specifies Twr.
Configuration options: [Auto] [Manual]
The following item appears only when Twr Ctrl is set to [Manual].
Twr [12]
Specifies the Minimum Write Recovery Time. Valid values 51h-Ah.
Trcpage Ctrl [Auto]
Specifies Trcpage.
Configuration options: [Auto] [Manual]
The following item appears only when Trcpage Ctrl is set to [Manual].
Trcpage [0]
SDRAM Optional Features (tMAW MAC). Valid values 3FFh-0h.
TrdrdScL Ctrl [Auto]
Specifies TrdrdScL.
Configuration options: [Auto] [Manual]
The following item appears only when TrdrdScL Ctrl is set to [Manual].
TrdrdScL [3]
Specifies the CAS to CAS Delay Time, same bank group. Valid values
Fh-1h.
TwrwrScL Ctrl [Auto]
Specifies TwrwrScL.
Configuration options: [Auto] [Manual]
The following item appears only when TwrwrScL Ctrl is set to [Manual].
TwrwrScL [3]
Specifies the CAS to CAS Delay Time, same bank group. Valid values
3Fh-1h.
Trfc Ctrl [Auto]
Specifies Trfc.
Configuration options: [Auto] [Manual]
The following item appears only when Trfc Ctrl is set to [Manual].
Trfc [138]
Specifies the Refresh Recovery Delay Time (tRFC1). Valid values 3DEh-
3Ch.
Trfc2 Ctrl [Auto]
Specifies Trfc2.
Configuration options: [Auto] [Manual]
5-43
ASUS RS700A-E11 Series
The following item appears only when Trfc2 Ctrl is set to [Manual].
Trfc2 [c0]
Specifies the Refresh Recovery Delay Time (tRFC2). Valid values 3DEh-
3Ch.
Trfc4 Ctrl [Auto]
Specifies Trfc4.
Configuration options: [Auto] [Manual]
The following item appears only when Trfc4 Ctrl is set to [Manual].
Trfc4 [84]
Specifies the Refresh Recovery Delay Time (tRFC4). Valid values 3DEh-
3Ch.
Tcwl [Auto]
Specifies the CAS Write Latency.
Configuration options: [Auto] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Eh Clk]
[10h Clk] [12h Clk] [14h Clk]
Trtp [Auto]
Specifies theRead CAS# to Precharge Delay Time.
Configuration options: [Auto] [5 Clk] [6 Clk] [7 Clk] [8 Clk] [9 Clk] [0Ah Clk]
[0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk]
Tcke [Auto]
Specifies the CKE minimum high and low pulse width in memory clock
cycles.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk] [10h Clk] [11h Clk] [12h Clk] [13h Clk] [14h Clk] [15h Clk] [16h Clk]
[17h Clk] [18h Clk] [19h Clk] [1Ah Clk] [1Bh Clk] [1Ch Clk] [1Dh Clk] [1Eh
Clk] [1Fh Clk]
Trdwr [Auto]
Specifies the Read to Write turnaround timing.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk] [10h Clk] [11h Clk] [12h Clk] [13h Clk] [14h Clk] [15h Clk] [16h Clk]
[17h Clk] [18h Clk] [19h Clk] [1Ah Clk] [1Bh Clk] [1Ch Clk] [1Dh Clk] [1Eh
Clk] [1Fh Clk]
Twrrd [Auto]
Specifies the Write to Read turnaround timing.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk]
TwrwrSc [Auto]
Specifies the Write to Write turnaround timing in the same chipselect.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk]
5-44 Chapter 5: BIOS Setup
TwrwrSd [Auto]
Specifies the Write to Write turnaround timing in the same DIMM.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk]
TwrwrDd [Auto]
Specifies the Write to Write turnaround timing in a different DIMM.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk]
TrdrdSc [Auto]
Specifies the Read to Read turnaround timing in the same chipselect.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk]
TrdrdSd [Auto]
Specifies the Read to Read turnaround timing in the same DIMM.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk]
TrdrdDd [Auto]
Specifies the Read to Read turnaround timing in a different DIMM.
Configuration options: [Auto] [1 Clk] [2 Clk] [3 Clk] [4 Clk] [5 Clk] [6 Clk] [7
Clk] [8 Clk] [9 Clk] [0Ah Clk] [0Bh Clk] [0Ch Clk] [0Dh Clk] [0Eh Clk] [0Fh
Clk]
ProcODT [Auto]
Specifies the Processor ODT.
Configuration options: [Auto] [High Impedance] [480 ohm] [240 ohm] [160
ohm] [120 ohm] [96 ohm] [80 ohm] [68.6 ohm] [60 ohm] [53.3 ohm] [48
ohm] [43.6 ohm] [40 ohm] [36.9 ohm] [34.3 ohm] [32 ohm] [30 ohm] [28.2
ohm]
DRAM Controller Configuration
DRAM Power Options
Power Down Enable [Auto]
This item allows you to enable or disable power down mode.
Configuration options: [Disabled] [Enabled] [Auto]
SubUrgRefLowerBound [4]
Specifies the stored refresh limit required to enter sub-urgent refresh mode.
Constraint: SubUrgRefLowerBound <= UrgRefLimit. Valid value: 6~1
UrgRefLimit [6]
Specifies the stored refresh limit required to enter urgent refresh mode.
Constraint: SubUrgRefLowerBound <= UrgRefLimit. Valid value: 6~1
DRAM Maximum Activate Count [Auto]
Override DIMM SPD Byte 7 [3:0]. Maximum Activate Count (MAC). When
set to [Auto] it will be based on SPD setting.
Configuration options: [Untested MAC] [700 K] [600 K] [500 K] [400 K] [300
K] [200 K] [Unlimited MAC] [Auto]
5-45
ASUS RS700A-E11 Series
DRAM Refresh Rate [7.8 usec]
Configuration options: [7.8 usec] [3.9 usec]
Self-Refresh Exit Staggering [Disabled]
Tcksrx += (Trfc/n * (UMC_Number % 4)), here n = 3 or 4.
Configuration options: [Disabled] [Trfc / 3] [Trfc / 4]
Cmd2T
Select between 1T and 2T mode on ADDR/CMD.
Configuration options: [Auto] [1T] [2T]
Gear Down Mode
Configuration options: [Auto] [Disabled] [Enabled]
CAD Bus Configuration
CAD Bus Timing User Controls [Auto]
This item allows you to set the CAD bus signals to Auto or Manual.
Configuration options: [Auto] [Manual]
The following items appear only when you set CAD Bus Timing User Controls to
[Manual].
AddrCmdSetup [0]
This item allows you to setup time on CAD bus signals.
Configuration options: [0] – [39]
CsOdtSetup [0]
This item allows you to setup time on CAD bus signals.
Configuration options: [0] – [39]
CkeSetup [0]
This item allows you to setup time on CAD bus signals.
Configuration options: [0] – [39]
CAD Bus Drive Strength User Controls [Auto]
This item allows you to set the CAD bus signals to Auto or Manual.
Configuration options: [Auto] [Manual]
The following items appear only when you set CAD Bus Drive Strength User Controls to
[Manual].
ClkDrvStren [Auto]
Configuration options: [Auto] [120.0 Ohm] [60.0 Ohm] [40.0 Ohm] [30.0
Ohm] [24.0 Ohm] [20.0 Ohm]
AddrCmdDrvStren [Auto]
Configuration options: [Auto] [120.0 Ohm] [60.0 Ohm] [40.0 Ohm] [30.0
Ohm] [24.0 Ohm] [20.0 Ohm]
Cs0dtDrvStren [Auto]
Configuration options: [Auto] [120.0 Ohm] [60.0 Ohm] [40.0 Ohm] [30.0
Ohm] [24.0 Ohm] [20.0 Ohm]
CkeDrvStren [Auto]
Configuration options: [Auto] [120.0 Ohm] [60.0 Ohm] [40.0 Ohm] [30.0
Ohm] [24.0 Ohm] [20.0 Ohm]
5-46 Chapter 5: BIOS Setup
Data Bus Configuration
Data Bus Configuration User Controls [Auto]
This item allows you to specify the mode for drive strength.
Configuration options: [Auto] [Manual]
The following items appear only when you set Data Bus Configuration User Controls to
[Manual].
RttNom [Auto]
Configuration options: [Rtt_Nom Disable] [RZQ/4] [RZQ/2] [RZQ/6] [RZQ/1]
[RZQ/5] [RZQ/3] [RZQ/7] [Auto]
RttWr [Auto]
Configuration options: [Dynamic ODT Off] [RZQ/2] [RZQ/1] [Hi-Z] [RZQ/3]
[Auto]
RttPark [Auto]
Configuration options: [Rtt_PARK Disable] [RZQ/4] [RZQ/2] [RZQ/6]
[RZQ/1] [RZQ/5] [RZQ/3] [RZQ/7] [Auto]
Common RAS
Data Poisoning [Auto]
Configuration options: [Enabled] [Disabled] [Auto]
DRAM Post Package Repair [Disable]
This item allows you to enable or disable DRAM POST Package Repair.
Configuration options: [Enable] [Disable]
RCD Parity [Auto]
Configuration options: [Enabled] [Disabled] [Auto]
DRAM Address Command Parity Retry [Auto]
Configuration options: [Enabled] [Disabled] [Auto]
The following item appears only when you set DRAM Address Command Parity Retry to
[Enabled].
Max Parity Error Replay [8]
The values in hex, 1, 2, or 3 is invalid.
Configuration options: [0] – [39]
Write CRC Enable [Auto]
Configuration options: [Enabled] [Disabled] [Auto]
DRAM Write CRC Enable and Retry Limit [Auto]
Configuration options: [Enabled] [Disabled] [Auto]
The following item appears only when you set DRAM Write CRC Enable and Retry Limit
to [Enabled].
Max Write CRC Error Replay [8]
The values in hex, 1, 2, or 3 is invalid.
Configuration options: [0] – [39]
Disable Memory Error Injection [True]
Configuration options: [False] [True]
5-47
ASUS RS700A-E11 Series
ECC Configuration
DRAM ECC Symbol Size [Auto]
Configuration options: [x4] [x8] [x16] [Auto]
DRAM ECC Enable [Auto]
This option allows you to enable or disable DRAM ECC. Auto will set ECC
to enable.
Configuration options: [Disabled] [Enabled] [Auto]
DRAM UECC Retry [Auto]
This option allows you to enable or disable DRAM UECC Retry.
Configuration options: [Disabled] [Enabled] [Auto]
Security
TSME [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
Data Scramble [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
DRAM Memory Mapping
Chipselect Interleaving [Auto]
This item allows you to set interleave memory blocks across the DRAM chip selects for
node 0.
Configuration options: [Disabled] [Auto]
BankGroupSwap [Auto]
Configuration options: [Enabled] [Disabled] [Auto]
BankGroupSwapAlt [Auto]
Configuration options: [Enabled] [Disabled] [Auto]
Address Hash Bank [Auto]
This item allows you to enable or disable bank address hashing.
Configuration options: [Enabled] [Disabled] [Auto]
Address Hash CS [Auto]
This item allows you to enable or disable CS address hashing.
Configuration options: [Enabled] [Disabled] [Auto]
Address Hash RM [Auto]
This item allows you to enable or disable RM address hashing.
Configuration options: [Enabled] [Disabled] [Auto]
SPD Read Optimization [Auto]
This item allows you to enable or disable SPD Read Optimization, if set to [Enabled],
SPD reads are skipped for Reserved fields and most of upper 256 Bytes. If set to
[Disabled], read all 512 SPD Bytes.
Configuration options: [Enabled] [Disabled] [Auto]
5-48 Chapter 5: BIOS Setup
Memory MBIST
MBIST Enable [Disabled]
This item allows you to enable or disable Memory MBIST.
Configuration options: [Enabled] [Disabled]
The following items appear only when MBIST Enable is set to [Enabled].
MBIST Test Mode [Auto]
This item allows you to select the MBIST Test Mode - Interface Mode (Tests Single
and Multiple CS transactions and Basic Connectivity) or Data Eye Mode (Measures
Voltage vs. Timing).
Configuration options: [Interface Mode] [Data Eye Mode] [Both] [Auto]
MBIST Aggressors [Auto]
This item allows you to enable or disable Memory Aggressor test.
Configuration options: [Enabled] [Disabled] [Auto]
MBIST Per Bit Slave Die Reporting [Auto]
Reports 2D Data Eye Results in ABL Log for each DQ, Chipselect, and Channel.
Configuration options: [Enabled] [Disabled] [Auto]
Data Eye
Pattern Select [PRBS]
Configuration options: [PRBS] [SS0] [Both]
Pattern Length [3]
This token helps to determine the pattern length. The possible options are
N=3...12.
Configuration options: [3] – [9]
Aggressor Channel [1 Aggressor Channel]
This helps read the aggressors channels. If set to [Enabled], you can
read from one or more than one aggressor channel. The default is set to
[Disabled].
Configuration options: [Disabled] [1 Aggressor Channel] [3 Aggressor
Channels] [7 Aggressor Channels]
Aggressor Static Lane Control [Disabled]
Configuration options: [Disabled] [Enabled]
The following items appear only when Aggressor Static Lane Control is set to [Enabled].
Aggressor Static Lane Select Upper 32 bits [0]
Static Lane Select for Upper 32 bits. The bit mask represents the bits to be
read.
Configuration options: [0] – [99999999]
Aggressor Static Lane Select Lower 32 bits [0]
Static Lane Select for Lower 32 bits. The bit mask represents the bits to be
read.
Configuration options: [0] – [99999999]
5-49
ASUS RS700A-E11 Series
Aggressor Static Lane Select ECC [0]
Static Lane Select for ECC Lanes. The bit mask represents the bits to be
read.
Configuration options: [0] – [9]
Aggressor Static Lane Value [0]
Configuration options: [0] – [9]
Target Static Lane Control [Disabled]
Configuration options: [Disabled] [Enabled]
The following items appear only when Target Static Lane Control is set to [Enabled].
Target Static Lane Select Upper 32 bits [0]
Static Lane Select for Upper 32 bits. The bit mask represents the bits to be
read.
Configuration options: [0] – [99999999]
Target Static Lane Select Lower 32 bits [0]
Static Lane Select for Lower 32 bits. The bit mask represents the bits to be
read.
Configuration options: [0] – [99999999]
Target Static Lane Select ECC [0]
Static Lane Select for ECC Lanes. The bit mask represents the bits to be
read.
Configuration options: [0] – [9]
Target Static Lane Value [0]
Configuration options: [0] – [9]
Data Eye Type [Worst Case Margin Only]
This option determines which results are expected to be captured for Data
Eye. Supported options are 1D Voltage Sweep, 1D Timing Sweep, 2D Full
Data Eye and Worst Case Margin only.
Configuration options: [1D Voltage Sweep] [1D Timing Sweep] [2D Full
Data Eye]
Worst Case Margin Granularity [Per Chip Select]
Configuration options: [Per Chip Select] [Per Nibble]
Read Voltage Sweep Step Size [2]
This option determines the step size for Read Data Eye voltage sweep.
Configuration options: [1] [2] [4]
Read Timing Sweep Step Size [1]
This option supports step size for Read Data Eye.
Configuration options: [1] [2] [4]
Write Voltage Sweep Step Size [2]
This option determines the step size for write Data Eye voltage sweep.
Configuration options: [1] [2] [4]
Write Timing Sweep Step Size [1]
This option supports step size for write Data Eye.
Configuration options: [1] [2] [4]
5-50 Chapter 5: BIOS Setup
5.11.4 NBIO Common Options
IOMMU [Auto]
This item allows you to enable or disable IOMMU.
Configuration options: [Disabled] [Enabled] [Auto]
ACS Enable [Auto]
AER must be enabled for ACS enable to work.
Configuration options: [Disable] [Enable] [Auto]
PCIe ARI Auto Config [Enable]
Support PCie ARI Auto Detect Rule.
Configuration options: [Disable] [Enable]
The following item appears only when PCIe ARI Auto Config is set to [Disable].
PCIe ARI Support [Auto]
This item enables Alternative Routing-ID Interpretation.
Configuration options: [Disable] [Enable] [Auto]
PCIe Ten Bit Tag Support [Auto]
This item enables PCIe ten bit tags for supported devices. [Auto] = [Disabled].
Configuration options: [Disable] [Enable] [Auto]
SMU Common Options
Determinism Control [Auto]
[Auto] Use the fused Determinism.
[Manual] User can set customized Determinism.
The following item appears only when Determinism Control is set to [Manual].
Determinism Slider [Auto]
Configuration options: [Auto] [Power] [Performance]
5-51
ASUS RS700A-E11 Series
cTDP Control [Manual]
[Auto] Use the fused TDP.
[Manual] User can set customized TDP.
The following item appears only when cTDP Control is set to [Manual].
cTDP [240]
This item allows you to customize cTDP.
Power Package Limit Control [Manual]
[Auto] Use the fused PPT.
[Manual] User can set customized PPT.
The following item appears only when Power Package Limit Control is set to [Manual].
Power Package Limit [240]
This item allows you to customize PPT.
APBDIS [Auto]
[0] Not APBDIS (mission mode)
[1] APBDIS
[Auto] Auto
DF Cstates [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
CPPC [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
HSMP Support [Auto]
This option allows you to enable or disable HSMP support.
Configuration options: [Disabled] [Enabled] [Auto]
Diagnostic Mode [Auto]
This option allows you to enable or disable Diag mode.
Configuration options: [Disabled] [Enabled] [Auto]
DLWM Support [Auto]
This option allows you to enable or disable DLWM support.
Configuration options: [Disabled] [Enabled] [Auto]
Boost FmaxEn [Auto]
[Auto] Use the default Fmax.
[Manual] User can set the boost Fmax.
5-52 Chapter 5: BIOS Setup
The following item appears only when Boost FmaxEn is set to [Manual].
Power Package Limit [0]
This item allows you to specify the boost Fmax frequency limit to apply to all cores
(MHz).
NBUI RAS Common Options
NBIO RAS Global Control [Auto]
Configuration options: [Auto] [Manual]
NBIO RAS Control [Auto]
Configuration options: [Disabled] [MCA] [Legacy] [Auto]
Egress Poison Severity High [30011]
Each bit set to 1 enables HIGH severity on the associated IOHC egress port. A bit of 0
indicates LOW severity.
Egress Poison Severity Low [4]
Each bit set to 1 enables HIGH severity on the associated IOHC egress port. A bit of 0
indicates LOW severity.
NBIO SyncFlood Generation [Auto]
This value may be used to mask SyncFlood caused by NBIO RAS options. When set
to TRUE, SyncFlood from NBIO is masked. When set to FALSE, NBIO is capable of
generating SyncFlood.
Configuration options: [Disabled] [Enabled] [Auto]
NBIO SyncFlood Reporting [Disabled]
This value may be used to enable SyncFlood reporting to APML. When set to TRUE,
SyncFlood will be reported to APML. When set to FALSE, the reporting will be
disabled.
Configuration options: [Disabled] [Enabled]
Egress Poison Mask High [fffcffff]
These set the enable mask for masking of errors logged in EGRESS_POISON_
STATUS. For each bit set to 1, errors are masked. For each bit set to 0, errors trigger
response actions.
Egress Poison Mask Low [fffffffb]
These set the enable mask for masking of errors logged in EGRESS_POISON_
STATUS. For each bit set to 1, errors are masked. For each bit set to 0, errors trigger
response actions.
Uncorrected Converted to Poison Enable Mask High [30000]
These set the enable mask for masking of uncorrectable parity errors on internal
arrays. For each bit set to 1, a system fatal error event is triggered for UCP errors on
arrays associated with that egress port. For each bit set to 0, errors are masked.
5-53
ASUS RS700A-E11 Series
Uncorrected Converted to Poison Enable Mask Low [4]
These set the enable mask for masking of uncorrectable parity errors on internal
arrays. For each bit set to 1, a system fatal error event is triggered for UCP errors on
arrays associated with that egress port. For each bit set to 0, errors are masked.
System Hub Watchdog Timer [a28]
This value specifies the timer interval of the SYSHUB Watchdog Timer in milliseconds.
SLink Read Response OK [Disabled]
This value specifies whether SLINK read response errors are converted to an Okay
response. When this value is set to TRUE, read response errors are converted to Okay
responses with data of all FFs. When set to FALSE, read response errors are not
converted.
SLink Read Response OK [Disabled]
This value specifies whether SLINK read response errors are converted to an Okay
response. When this value is set to TRUE, read response errors are converted to Okay
responses with data of all FFs. When set to FALSE, read response errors are not
converted.
Configuration options: [Disabled] [Enabled]
SLink Read Response Error Handling [Log Errors in MCA]
This value specifies whether SLINK write response errors are converted to an Okay
response. When this value is set to 0, write response errors will be logged in the MCA.
When set to 1, write response errors will trigger an MCOMMIT error. When this value is
set to 2, write response errors are converted.
Configuration options: [Enabled] [Trigger MCOMMIT Error] [Log Errors in MCA]
Log Poison data from SLINK [Disabled]
This value specifies whether poison data propagated from SLINK will generate a
deferred error. When this value is set to TRUE, deferred errors are enabled. When set
to FALSE, errors are not generated.
Configuration options: [Disabled] [Enabled]
PCIe Aer Reporting Mechanism [Auto]
This value selects the method of reporting AER errors from PCI Express. A value of 0
indicates that the hardware will report the error through MCA. A value of 1 allows OS
First handling of the errors through generation of a system control interrupt (SCI). A
value of 2 allows Firmware First handling of the errors through generation of a system
control interrupt (SCI).
Configuration options: [Firmware First] [OS First] [MCA] [Auto]
Edge Control [Disabled]
Configuration options: [Disabled] [Enabled] [Auto]
NBIO Poison Consumption [Auto]
Configuration options: [Disabled] [Enabled] [Auto]
Sync Flood on PCIe Fatal Error [Auto]
Configuration options: [Auto] [True] [False]
5-54 Chapter 5: BIOS Setup
Enable AER Cap [Auto]
This item allows you to enable or disable Advanced Error Reporting Capability.
Configuration options: [Enable] [Disabled] [Auto
Enable Rcv Err and Bad TLP Mask [Auto]
This item allows you to enable or disable Masking of Receiver Error and Bad TLP at Gen4
x2.
Configuration options: [Enable] [Disabled] [Auto]]
Early Link Speed [Auto]
This item allows you to set Early Link Speed.
Configuration options: [Auto] [Gen1] [Gen2]
Hot Plug Handling mode [Auto]
This item allows you to control the Hot Plug Handling mode.
Configuration options: [A0 Mode] [OS First (No Error Handling)] [OS First (Error Handling -
Not Implemented)] [Firmware First (Not Implemented)] [Auto]
Presence Detect Select mode [Auto]
This item allows you to control the Presence Detect Select mode.
Configuration options: [OR] [AND] [Auto]
Loopback Mode [Auto]
This item allows you to enable or disable PCIe Loopback Mode.
Configuration options: [Auto] [Disabled] [Enabled]
CV test [Auto]
Set this to [Enabled] to support running PCIECV tool. Selecting [Auto] will preserve h/w
defaults.
Configuration options: [Auto] [Disabled] [Enabled]
NTB Enable [Auto]
This item allows you to enable or disable NTB.
Configuration options: [Auto] [Enable]
The following item appears only when you set NTB Enable to [Enable].
NTB Location [Auto]
Configuration options: [Auto] [Socket0-Die0] [Socket0-Die1] [Socket0-Die2] [Socket0-Die3]
[Socket1-Die0] [Socket1-Die1] [Socket1-Die2] [Socket1-Die3]
5.11.5 NTB Common Options
5-55
ASUS RS700A-E11 Series
NTB active on PCIeCore [Auto]
Configuration options: [Auto] [Core0] [Core1]
NTB Mode [Auto]
This item allows you to select the NTB Mode (Core 0, Port 0)
Configuration options: [NTB Disabled] [NTB Primary] [NTB Secondary] [NTB Random] [Auto]
Link Speed [Auto]
This item allows you to select the Link Speed for NTB Mode (Core 0, Port 0).
Configuration options: [Max Speed] [Gen 1] [Gen 2] [Gen 3] [Auto] [Gen 4]
5.12 Event Logs menu
The Event Logs menu items allow you to change the event log settings and view the system
event logs.
5.12.1 Change Smbios Event Log Settings
Press <Enter> to change the Smbios Event Log configuration.
All values changed here do not take effect until computer is restarted.
5-56 Chapter 5: BIOS Setup
5.12.2 View Smbios Event Log
Press <Enter> to view all smbios event logs.
Enabling/Disabling Options
Smbios Event Log [Enabled]
Change this to enable or disable all features of Smbios Event Logging during boot.
Configuration options: [Disabled] [Enabled]
The following items appear only when Smbios Event Log is set to [Enabled].
Erasing Settings
Erase Event Log [No]
Choose options for erasing Smbios Event Log. Erasing is done prior to any logging activation
during reset.
Configuration options: [No] [Yes, Next reset] [Yes, Every reset]
Smbios Event Log Standard Settings
Log System Boot Event [Disabled]
This option allows you to enable or disable logging System boot event.
Configuration options: [Disabled] [Enabled]
MECI [1]
The Multiple Event Count Increment is the occurrences of a duplicate event that must pass
before the multiple-event counter of log entry is updated. The values range from 1 to 255.
METW [60]
The Multiple Event Time Window is the number of minutes which must pass between
duplicate log entries which utilize a multiple-event counter. The values range from 0 to 99
minutes.
Custom Options
Log EFI Status Code [Enabled]
This option allows you to enable or disable logging of the EFI Status Codes.
Configuration options: [Disabled] [Enabled]
The following item appears only when Log EFI Status Code is set to [Enabled].
Convert EFI Status Codes to Standard Smbios Type [Disabled]
This option allows you to enable or disable converting of EFI Status Codes to Standard
Smbios Type (Not all may be translated).
Configuration options: [Disabled] [Enabled]
5-57
ASUS RS700A-E11 Series
5.13 Server Mgmt menu
The Server Management menu displays the server management status and allows you to
change the settings.
FRB-2 Timer [Enabled]
Allows you to enable or disable FRB-2 timer (POST timer).
Configuration options: [Disabled] [Enabled]
The following items appear only when FRB-2 Timer is set to [Enabled].
FRB-2 Timer timeout [6 minutes]
Allows you to select the FRB-2 Timer Expiration value.
Configuration options: [3 minutes] [4 minutes] [5 minutes] [6 minutes]
FRB-2 Timer Policy [Do Nothing]
Allows you to select the how the system should respond in FRB-2 Timer expires.
Configuration options: [Do Nothing] [Reset] [Power Down] [Power Cycle]
OS Watchdog Timer [Disabled]
This item allows you to start a BIOS timer which can only be shut off by Intel Management
Software after the OS loads.
Configuration options: [Disabled] [Enabled]
5-58 Chapter 5: BIOS Setup
The following items are configurable only when the OS Watchdog Timer is set to
[Enabled].
OS Wtd Timer Timeout [10 minutes]
Allows you to configure the length fo the OS Boot Watchdog Timer.
Configuration options: [5 minutes] [10 minutes] [15 minutes] [20 minutes]
OS Wtd Timer Policy [Reset]
This item allows you to configure the how the system should respond if the OS Boot
Watch Timer expires.
Configuration options: [Do Nothing] [Reset] [Power Down]
System Event Log
Allows you to change the SEL event log configuration.
Erase SEL [No]
Allows you to choose options for erasing SEL.
Configuration options: [No] [Yes, On next reset] [Yes, On every reset]
All values changed here do not take effect until computer is restarted.
View FRU Information
Press <Enter> to view FRU information.
No FRU information for fields indicate information needs to be filled by O.E.M.
BMC network configuration
The sub-items in this configuration allow you to configure the BMC network parameters.
Configure IPV4 support
DM_LAN1/Shared LAN
Configuration Address source [Previous State]
This item allows you to configure LAN channel parameters statistically or dynamically
(by BIOS or BMC). [Previous State] option will not modify any BMC network
parameters during BIOS phase.
Configuration options: [Previous State] [Static] [DynamicBmcDhcp]
The following items are available only when Configuration Address source is set to
[Static].
Station IP address
Allows you to set the station IP address.
Subnet mask
Allows you to set the subnet mask. We recommend that you use the same Subnet
Mask you have specified on the operating system network for the used network card.
5-59
ASUS RS700A-E11 Series
Router IP Address
Allows you to set the router IP address.
Router MAC Address
Allows you to set the router MAC address.Shared LAN
Configure IPV6 support
DM_LAN1/Shared LAN
IPV6 Support [Enabled]
Allows you to enable or disable LAN1 IPV6 Support.
Configuration options: [Disabled] [Enabled]
The following item appears only when IPV6 Support is set to [Enabled].
Configuration Address source [Previous State]
This item allows you to configure LAN channel parameters statistically or dynamically
(by BIOS or BMC). [Previous State] option will not modify any BMC network
parameters during BIOS phase.
Configuration options: [Previous State] [Static] [DynamicBmcDhcp]
The following items are available only when Configuration Address source is set to
[Static].
Station IPV6 address
Allows you to set the station IPV6 address.
Prefix Length
Allows you to set the prefix length (maximum of Prefix Length is 128).
IPV6 Router1 IP Address
Allows you to set the IPV6 Router1 IP address.
View System Event Log
This item allows you to view the system event log records.
BMC User Settings
The sub-items in this configuration allow you to add, delete, or change BMC user settings.
BMC Warm Reset
Press <Enter> to perform a BMC Warm Reset.
5-60 Chapter 5: BIOS Setup
6
Driver Installation
This chapter provides instructions for installing the necessary
drivers for different system components.
Chapter 6: Driver Installation
6-2 Chapter 6: Driver Installation
6.1 Running the Support DVD
The support DVD that is bundled with your motherboard contains drivers, management
applications, and utilities that you can install to maximize the features of your motherboard.
• The contents of the support DVD are subject to change at any time without notice.
Visit the ASUS website (www.asus.com) for the latest updates on software and
utilities.
• The support DVD is supported on Windows® Server 2016 and Windows® Server 2019.
The main screen of the Support DVD contains the following tabs:
1. Drivers - Shows the available device drivers that the system detects.
2. Utilities - Displays the software applications and utilities that the motherboard supports.
3. Manual - Provides the link to the user guide(s).
You need an internet browser installed in your OS to view the User Guide.
4. Contact - Displays the ASUS contact information, e-mail addresses, and useful links if
you need more information or technical support for your motherboard.
Appendix
Appendix
This appendix includes additional information that you may refer
to when configuring the motherboard.
A-2 Appendix
KMPP-D32 block diagram
ASUS RS700A-E11 Series A-3
Notices
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
• This device may not cause harmful interference.
• This device must accept any interference received including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
The use of shielded cables for connection of the monitor to the graphics card is required
to assure compliance with FCC regulations. Changes or modifications to this unit not
expressly approved by the party responsible for compliance could void the user’s authority
to operate this equipment.
Compliance Statement of Innovation, Science and Economic
Development Canada (ISED)
This device complies with Innovation, Science and Economic Development Canada licence
exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
CAN ICES-003(A)/NMB-003(A)
Déclaration de conformité de Innovation, Sciences et
Développement économique Canada (ISED)
Le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement
économique Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
CAN ICES-003(A)/NMB-003(A)
Japan JATE
本製品は電気通信事業者(移動通信会社、固定通信会社、インターネットプロバイダ等)の通信
回線(公衆無線LANを含む)に直接接続することができません。本製品をインターネットに接続す
る場合は、必ずルータ等を経由し接続してください。」等が考えられる。
A-4 Appendix
Australia statement notice
From 1 January 2012 updated warranties apply to all ASUS products, consistent with the
Australian Consumer Law. For the latest product warranty details please visit
https://www.asus.com/support/. Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality
and the failure does not amount to a major failure.
If you require assistance please call ASUS Customer Service 1300 2787 88 or visit us at
https://www.asus.com/support/.
DO NOT throw the motherboard in municipal waste. This product has been designed to
enable proper reuse of parts and recycling. This symbol of the crossed out wheeled bin
indicates that the product (electrical and electronic equipment) should not be placed in
municipal waste. Check local regulations for disposal of electronic products.
DO NOT throw the mercury-containing button cell battery in municipal waste. This symbol
of the crossed out wheeled bin indicates that the battery should not be placed in municipal
waste.
Japan statement notice
This product cannot be directly connected to the Internet (including public wireless LAN) of a
telecom carrier (mobile network companies, landline network companies, Internet providers,
etc.). When connecting this product to the Internet, be sure to connect it through a router or
switch.
Declaration of compliance for product environmental
regulation
ASUS follows the green design concept to design and manufacture our products, and
makes sure that each stage of the product life cycle of ASUS product is in line with global
environmental regulations. In addition, ASUS disclose the relevant information based on
regulation requirements.
Please refer to http://csr.asus.com/Compliance.htm for information disclosure based on
regulation requirements ASUS is complied with:
EU REACH and Article 33
Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of
Chemicals) regulatory framework, we publish the chemical substances in our products at ASUS
REACH website at http://csr.asus.com/english/REACH.htm.
EU RoHS
This product complies with the EU RoHS Directive. For more details, see
http://csr.asus.com/english/article.aspx?id=35
Japan JIS-C-0950 Material Declarations
Information on Japan RoHS (JIS-C-0950) chemical disclosures is available on
http://csr.asus.com/english/article.aspx?id=19
ASUS RS700A-E11 Series A-5
India RoHS
This product complies with the “India E-Waste (Management) Rules, 2016” and prohibits
use of lead, mercury, hexavalent chromium, polybrominated biphenyls (PBBs) and
polybrominated diphenyl ethers (PBDEs) in concentrations exceeding 0.1% by weight in
homogenous materials and 0.01% by weight in homogenous materials for cadmium, except
for the exemptions listed in Schedule II of the Rule.
Vietnam RoHS
ASUS products sold in Vietnam, on or after September 23, 2011,meet the requirements of
the Vietnam Circular 30/2011/TT-BCT.
Các sản phẩm ASUS bán tại Việt Nam, vào ngày 23 tháng 9 năm2011 trở về sau, đều phải đáp ứng
các yêu cầu của Thông tư 30/2011/TT-BCT của Việt Nam.
Turkey RoHS
AEEE Yönetmeliğine Uygundur
ASUS Recycling/Takeback Services
ASUS recycling and takeback programs come from our commitment to the highest standards
for protecting our environment. We believe in providing solutions for you to be able to
responsibly recycle our products, batteries, other components as well as the packaging
materials. Please go to http://csr.asus.com/english/Takeback.htm for detailed recycling
information in different regions.
Ecodesign Directive
European Union announced a framework for the setting of ecodesign requirements for
energy-related products (2009/125/EC). Specific Implementing Measures are aimed at
improving environmental performance of specific products or across multiple product types.
ASUS provides product information on the CSR website. The further information could be
found at https://csr.asus.com/english/article.aspx?id=1555.
A-6 Appendix
ASUS contact information
ASUSTeK COMPUTER INC.
Address 1F., No. 15, Lide Rd., Beitou Dist., Taipei City 112, Taiwan
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
Web site https://www.asus.com
Technical Support
Telephone +86-21-38429911
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=en
ASUSTeK COMPUTER INC. (Taiwan)
Address 1F., No. 15, Lide Rd., Beitou Dist., Taipei City 112, Taiwan
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
Web site https://www.asus.com/tw/
Technical Support
Telephone +886-2-2894-3447 (0800-093-456)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=zh-tw
ASUSTeK COMPUTER INC. (China)
Address No. 5077, Jindu Road, Minhang District, Shanghai, China
Telephone +86-21-5442-1616
Fax +86-21-5442-0099
Web site https://www.asus.com.cn
Technical Support
Telephone +86-20-2804-7506 (400-620-6655)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=zh-cn
ASUS RS700A-E11 Series A-7
ASUS contact information
ASUS COMPUTER INTERNATIONAL (America)
Address 48720 Kato Rd., Fremont, CA 94538, USA
Fax +1-510-608-4555
Web site https://www.asus.com/us/
Technical Support
Support fax +1-812-284-0883
General support +1-812-282-2787
Online support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=en-us
ASUS COMPUTER GmbH (Germany and Austria)
Address Harkort Str. 21-23, 40880 Ratingen, Germany
Fax +49-2102-959911
Web site https://www.asus.com/de/
Technical Support
Telephone +49-1805-010923
Support Fax +49-2102-959911
Online support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=de-de
ASUS Czech Service s.r.o. (Europe)
Address Na Rovince 887, 720 00 Ostrava – Hrabová,
Czech Republic
Telephone +420-596766888
Web site https://www.asus.com/cz/
Technical Support
Telephone +420-596-766-891
Fax +420-596-766-329
E-mail advance.rma.eu@asus.com
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=cs-cz
A-8 Appendix
ASUS contact information
ASUS Holland BV (The Netherlands)
Address Marconistraat 2, 7825GD EMMEN, The Netherlands
Web site https://www.asus.com/nl/
Technical Support
Telephone +31-(0)591-5-70292
Fax +31-(0)591-666853
E-mail advance.rma.eu@asus.com
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=nl-nl
ASUS Polska Sp. z o.o. (Poland)
Address Ul. Postępu 6, 02-676 Warszawa, Poland
Web site https://www.asus.com/pl/
Technical Support
Telephone +48-225718033
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=pl-pl
ASK-Service (Russia and CIS)
Address
г.Москва, ул. Орджоникидзе, д.10, Россия
Telephone (495) 640-32-75
Web site https://www.asus.com/ru/
Technical Support
Telephone 008-800-100-ASUS (008-800-100-2787)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=ru-ru