Table of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Hardware Information
- Chapter 3: Powering Up
- Chapter 4: BIOS Setup
- 4.1 Managing and updating your BIOS
- 4.2 BIOS setup program
- 4.3 Main menu
- 4.4 Performance Tuning menu
- 4.5 Advanced menu
- 4.5.1 Trusted Computing
- 4.5.2 ACPI Settings
- 4.5.3 Smart Settings
- 4.5.4 Super IO Configuration
- 4.5.5 Serial Port Console Redirection
- 4.5.6 Onboard LAN Configuration
- 4.5.7 APM
- 4.5.8 PCI Subsystem Settings
- 4.5.9 USB Configuration
- 4.5.10 CSM Configuration
- 4.5.11 NVMe Configuration
- 4.5.12 Network Stack Configuration
- 4.5.13 iSCSI Configuration
- 4.6 Platform Configuration menu
- 4.7 Socket Configuration menu
- 4.8 Event Logs menu
- 4.9 Server Mgmt menu
- 4.10 Security menu
- 4.11 Boot menu
- 4.12 Tool menu
- 4.13 Save & Exit menu
- Chapter 5: RAID Configuration
- Chapter 6: Intel® Optane™ DC Persistent Memory Configuration
- 6.1 Working with Intel® Optane™ DC persistent memory
- 6.1.1 DCPMM operating systems (OS) and virtual machine monitor (VMM)
- 6.1.2 Setting up Intel® Optane™ DC persistent memory as memory modules
- 6.1.3 Setting up Intel® Optane™ DC persistent memory as storage devices (Windows)
- 6.1.4 Removing Intel® Optane™ DC persistent memory as storage devices (Windows)
- 6.1.5 Setting up Intel® Optane™ DC persistent memory on other operating systems
- 6.1 Working with Intel® Optane™ DC persistent memory
- Chapter 7: Driver Installation
- 7.1 RAID driver installation
- 7.2 Management applications and utilities installation
- 7.3 Running the Support DVD
- 7.4 Intel® chipset device software installation
- 7.5 Installing the Intel® I210 Gigabit Adapters driver
- 7.6 VGA driver installation
- 7.7 Intel® Rapid Storage Technology enterprise 5.0 installation
- Appendix
ASUS Z11PA-D8 User Manual
Displayed below is the user manual for Z11PA-D8 by ASUS which is a product in the Motherboards category. This manual has pages.
Related Manuals
Z11PA-D8 Series
User Guide
ii
E16295
Revised Edition V8
February 2020
Copyright © 2020 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced,
transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any
means, except documentation kept by the purchaser for backup purposes, without the express written
permission of ASUSTeK COMPUTER INC. (“ASUS”).
Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless
such repair, modication of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS
DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS,
LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE),
EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY
DEFECT OR ERROR IN THIS MANUAL OR PRODUCT.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR
INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE,
AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. ASUS ASSUMES NO
RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS
MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identication or explanation and to the
owners’ benet, without intent to infringe.
iii
Contents
Safety information .................................................................................................... viii
Z11PA-D8 Series specications summary .............................................................. xi
Chapter 1: Product Introduction
1.1 Welcome! .................................................................................................... 1-2
1.2 Package contents.......................................................................................1-2
1.3 Serial number label .................................................................................... 1-3
1.4 Special features.......................................................................................... 1-3
1.4.1 Product highlights........................................................................1-3
1.4.2 Innovative ASUS features ........................................................... 1-4
Chapter 2: Hardware Information
2.1 Before you proceed ................................................................................... 2-2
2.2 Motherboard overview ............................................................................... 2-3
2.2.1 Placement direction.....................................................................2-3
2.2.2 Screw holes.................................................................................2-3
2.2.3 Motherboard layout ..................................................................... 2-4
2.3 Central Processing Unit (CPU) ................................................................. 2-6
2.3.1 Installing the CPU ....................................................................... 2-6
2.4 System memory ......................................................................................... 2-8
2.4.1 Overview ..................................................................................... 2-8
2.4.2 Memory Congurations ............................................................... 2-8
2.4.3 Installing a DIMM on a single clip DIMM socket........................ 2-11
2.4.4 Removing a DIMM from a single clip DIMM socket .................. 2-11
2.5 Expansion slots........................................................................................2-12
2.5.1 Installing an expansion card......................................................2-12
2.5.2 Conguring an expansion card ................................................. 2-12
2.5.3 Interrupt assignments................................................................2-13
2.5.4 PCI Express x16 slot (x16 link) ................................................. 2-13
2.5.5 PCI Express x8 slot (x8 link) ..................................................... 2-13
2.6 Jumpers .................................................................................................... 2-15
2.7 Onboard LEDs .......................................................................................... 2-21
2.8 Connectors ............................................................................................... 2-25
2.8.1 Rear panel connectors .............................................................. 2-25
2.8.2 Internal connectors....................................................................2-26
iv
Contents
Chapter 3: Powering Up
3.1 Starting up for the rst time ...................................................................... 3-2
3.2 Powering off the computer........................................................................ 3-3
3.2.1 Using the OS shut down function ................................................ 3-3
3.2.2 Using the dual function power switch .......................................... 3-3
Chapter 4: BIOS Setup
4.1 Managing and updating your BIOS .......................................................... 4-2
4.1.1 ASUS CrashFree BIOS 3 utility................................................... 4-2
4.1.2 ASUS EZ Flash Utility ................................................................. 4-3
4.1.3 BUPDATER utility ....................................................................... 4-4
4.2 BIOS setup program .................................................................................. 4-6
4.2.1 BIOS menu screen ...................................................................... 4-7
4.2.2 Menu bar ..................................................................................... 4-7
4.2.3 Menu items..................................................................................4-8
4.2.4 Submenu items ........................................................................... 4-8
4.2.5 Navigation keys ........................................................................... 4-8
4.2.6 General help................................................................................4-8
4.2.7 Conguration elds ..................................................................... 4-8
4.2.8 Pop-up window............................................................................4-8
4.2.9 Scroll bar ..................................................................................... 4-8
4.3 Main menu .................................................................................................. 4-9
4.3.1 System Date [Day xx/xx/xxxx] ..................................................... 4-9
4.3.2 System Time [xx:xx:xx] ............................................................... 4-9
4.4 Performance Tuning menu...................................................................... 4-10
4.5 Advanced menu ....................................................................................... 4-11
4.5.1 Trusted Computing....................................................................4-12
4.5.2 ACPI Settings ............................................................................ 4-12
4.5.3 Smart Settings...........................................................................4-13
4.5.4 Super IO Conguration ............................................................. 4-13
4.5.5 Serial Port Console Redirection ................................................ 4-14
4.5.6 Onboard LAN Conguration ..................................................... 4-17
4.5.7 APM .......................................................................................... 4-18
v
Contents
4.5.8 PCI Subsystem Settings ........................................................... 4-19
4.5.9 USB Conguration .................................................................... 4-21
4.5.10 CSM Conguration .................................................................... 4-22
4.5.11 NVMe Conguration .................................................................. 4-23
4.5.12 Network Stack Conguration..................................................... 4-23
4.5.13 iSCSI Conguration................................................................... 4-24
4.6 Platform Conguration menu ................................................................. 4-24
4.6.1 PCH Conguration .................................................................... 4-25
4.6.2 Miscellaneous Conguration ..................................................... 4-27
4.6.3 Server ME Conguration ........................................................... 4-27
4.6.4 Runtime Error Logging Support ................................................ 4-28
4.7 Socket Conguration menu .................................................................... 4-28
4.7.1 Processor Conguration............................................................ 4-29
4.7.2 Common RefCode Conguration .............................................. 4-30
4.7.3 UPI Conguration ...................................................................... 4-31
4.7.4 Memory Conguration ............................................................... 4-32
4.7.5 IIO Conguration ....................................................................... 4-34
4.7.6 Advanced Power Management Conguration........................... 4-35
4.8 Event Logs menu ..................................................................................... 4-37
4.8.1 Change Smbios Event Log Settings ......................................... 4-37
4.8.2 View Smbios Event Log ............................................................ 4-37
4.9 Server Mgmt menu ................................................................................... 4-38
4.10 Security menu .......................................................................................... 4-39
4.11 Boot menu ................................................................................................ 4-41
4.12 Tool menu ................................................................................................. 4-42
4.13 Save & Exit menu ..................................................................................... 4-42
Chapter 5: RAID Conguration
5.1 Setting up RAID .......................................................................................... 5-2
5.1.1 RAID denitions .......................................................................... 5-2
5.1.2 Installing hard disk drives ............................................................ 5-3
5.1.3 Setting the RAID item in BIOS .................................................... 5-3
5.1.4 RAID conguration utilities .......................................................... 5-3
vi
Contents
5.2 Intel® Rapid Storage Technology enterprise SATA/SSATA Option
ROM Utility .................................................................................................. 5-4
5.2.1 Creating a RAID set .................................................................... 5-5
5.2.2 Deleting a RAID set.....................................................................5-7
5.2.3 Resetting disks to Non-RAID ...................................................... 5-8
5.2.4 Exiting the Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM utility ................................................ 5-9
5.2.5 Rebuilding the RAID....................................................................5-9
5.2.6 Setting the Boot array in the BIOS Setup Utility ........................ 5-11
5.3 Intel® Rapid Storage Technology enterprise (Windows) ...................... 5-12
5.3.1 Creating a RAID set .................................................................. 5-13
5.3.2 Changing a Volume Type..........................................................5-15
5.3.3 Deleting a volume ..................................................................... 5-16
5.3.4 Preferences ............................................................................... 5-17
5.4 Intel® Virtual Raid on CPU in BIOS ......................................................... 5-18
5.4.1 Creating a RAID set .................................................................. 5-19
5.4.2 Deleting a RAID set...................................................................5-21
5.4.3 Installing the RAID controller driver during Windows® 10
OS installation ........................................................................... 5-22
Chapter 6: Intel® Optane™ DC Persistent Memory Conguration
6.1 Working with Intel® Optane™ DC persistent memory ........................... 6-2
6.1.1 DCPMM operating systems (OS) and virtual
machine monitor (VMM) .............................................................. 6-2
6.1.2 Setting up Intel® Optane™ DC persistent memory
as memory modules .................................................................... 6-2
6.1.3 Setting up Intel® Optane™ DC persistent memory
as storage devices (Windows) .................................................... 6-3
6.1.4 Removing Intel® Optane™ DC persistent memory
as storage devices (Windows) .................................................... 6-4
6.1.5 Setting up Intel® Optane™ DC persistent memory
on other operating systems ......................................................... 6-4
vii
Contents
Chapter 7: Driver Installation
7.1 RAID driver installation ............................................................................. 7-2
7.1.1 Creating a USB ash drive with RAID drive ................................ 7-2
7.1.2 Installing the RAID controller driver............................................. 7-2
7.2 Management applications and utilities installation ................................ 7-5
7.3 Running the Support DVD ......................................................................... 7-5
7.4 Intel® chipset device software installation ............................................... 7-8
7.5 Installing the Intel® I210 Gigabit Adapters driver .................................. 7-10
7.6 VGA driver installation ............................................................................ 7-13
7.7 Intel® Rapid Storage Technology enterprise 5.0 installation ............... 7-15
Appendix
Z11PA-D8 Series block diagram (with SATA M.2 device) ................................... A-2
Z11PA-D8 Series block diagram (without SATA M.2 device) .............................. A-2
Q-Code table ............................................................................................................ A-3
Notices .................................................................................................................... A-5
Simplied EU Declaration of Conformity .............................................................. A-8
ASUS contact information ...................................................................................... A-9
viii
Safety information
Electrical safety
• To prevent electrical shock hazard, disconnect the power cable from the electrical outlet
before relocating the system.
• When adding or removing devices to or from the system, ensure that the power cables
for the devices are unplugged before the signal cables are connected. If possible,
disconnect all power cables from the existing system before you add a device.
• Before connecting or removing signal cables from the motherboard, ensure that all
power cables are unplugged.
• Seek professional assistance before using an adapter or extension cord. These devices
could interrupt the grounding circuit.
• Make sure that your power supply is set to the correct voltage in your area. If you are
not sure about the voltage of the electrical outlet you are using, contact your local power
company.
• If the power supply is broken, do not try to x it by yourself. Contact a qualied service
technician or your retailer.
Operation safety
• Before installing the motherboard and adding devices on it, carefully read all the manuals
that came with the package.
• Before using the product, make sure all cables are correctly connected and the power
cables are not damaged. If you detect any damage, contact your dealer immediately.
• To avoid short circuits, keep paper clips, screws, and staples away from connectors,
slots, sockets and circuitry.
• Avoid dust, humidity, and temperature extremes. Do not place the product in any area
where it may become wet.
• Place the product on a stable surface.
• If you encounter technical problems with the product, contact a qualied service
technician or your retailer.
ix
About this guide
This user guide contains the information you need when installing and conguring the
motherboard.
How this guide is organized
This user guide contains the following parts:
• Chapter 1: Product Introduction
This chapter describes the features of the motherboard and the new technologies it
supports.
• Chapter 2: Hardware Information
This chapter lists the hardware setup procedures that you have to perform when
installing system components. It includes description of the switches, jumpers, and
connectors on the motherboard.
• Chapter 3: Powering Up
This chapter describes the power up sequence and ways of shutting down the system.
• Chapter 4: BIOS Setup
This chapter tells how to change system settings through the BIOS Setup menus.
Detailed descriptions of the BIOS parameters are also provided.
• Chapter 5: RAID Conguration
This chapter provides instructions for setting up, creating, and conguring RAID sets
using the available utilities.
• Chapter 6: Intel® Optane™ DC Persistent Memory Conguration
This chapter provides instructions for conguring Intel® Optane™ DC persistent
memory as memory modules (Memory Mode) or storage devices (App Direct mode).
• Chapter 7: Driver Installation
This chapter provides instructions for installing the necessary drivers for different
system components.
• Appendix
This appendix includes additional information that you may refer to when conguring
the motherboard.
Where to nd more information
Refer to the following sources for additional information and for product and software
updates.
1. ASUS Control Center (ACC) user guide
This manual tells how to set up and use the proprietary ASUS server management
utility. Visit asuscontrolcenter.asus.com for more information.
2. ASUS websites
The ASUS websites worldwide provide updated information for all ASUS hardware and
software products. Refer to the ASUS contact information.
x
Conventions used in this guide
To ensure that you perform certain tasks properly, take note of the following symbols used
throughout this manual.
DANGER/WARNING: Information to prevent injury to yourself when trying to
complete a task.
CAUTION: Information to prevent damage to the components when trying to
complete a task.
IMPORTANT: Instructions that you MUST follow to complete a task.
NOTE: Tips and additional information to help you complete a task.
Typography
Bold text Indicates a menu or an item to select.
Italics Used to emphasize a word or a phrase.
<Key> Keys enclosed in the less-than and greater-than sign means
that you must press the enclosed key.
Example: <Enter> means that you must press the Enter or
Return key.
<Key1> + <Key2> + <Key3> If you must press two or more keys simultaneously, the key
names are linked with a plus sign (+).
Example: <Ctrl> + <Alt> + <Del>
Command Means that you must type the command exactly as shown,
then supply the required item or value enclosed in brackets.
Example: At DOS prompt, type the command line:
format A:/S
xi
Z11PA-D8 Series specications summary
Model Name Z11PA-D8
Processor Support /
System Bus
2 x 165W Socket P (LGA 3647)
1st Gen Intel® Xeon® Processor Scalable Family
2nd Gen Intel® Xeon® Processor Scalable Family
Core Logic Intel® Lewisburg PCH (C621)
Form Factor CEB
ASUS
Features
Fan Speed
Control
Rack Optimized
(Dedicated for
rack)
ASUS Control
Center
Memory
Total Slots 8 (4-channel per CPU, 4 DIMM per CPU)
Voltage 1.2V
Capacity Maximum up to 4096GB
Memory Type
DDR4 2933* (1 DIMM per Channel)
DDR4 2666/2400/2133 RDIMM/LRDIMM/LRDIMM 3DS
(2 DIMM per Channel)
Intel® Optane™ DC persistent memory (DCPMM)
* 2933MHz will drop to 2666MHz when using 2DPC congurations
** Refer to ASUS server AVL for the latest update
Memory Size
4GB, 8GB, 16GB, 32GB (RDIMM)
32GB, 64GB, 128GB (LRDIMM)
64GB, 128GB (3DS)
128GB, 256GB, 512GB (DCPMM)
Expansion
Slots (follow
SSI Location
number)
Total PCI/ PCI-X
/ PCI-E Slots 3
Slot Location 1 PCI-E x8 (x8 Gen3 Link) from CPU2
Slot Location 2 -
Slot Location 3 PCI-E x16 (x16 Gen3 Link) from CPU1
Slot Location 4 -
Slot Location 5 PCI-E x16 (x16 Gen3 Link) from CPU1
Slot Location 6 MIO
Slot Location 7 -
Additional Slot 1 -
Additional Slot 2 -
Networking LAN 4 x Intel I210AT
1 x Management Port
Graphic VGA Aspeed AST2500 64MB
(continued on the next page)
xii
Z11PA-D8 Series specications summary
Model Name Z11PA-D8
Storage
SATA Controller
Intel® Lewisburg PCH
- 12 x SATA 6Gb/s ports + 2 x M.2 connector (SATA 6Gb/s &
PCI-E Gen3 x4 link) from CPU1
Marvell 88SE9230
- 4 x SATA 6Gb/s ports
SAS Controller
Optional kits:
ASUS PIKE II 3008 8-port SAS 12G HW RAID card
ASUS PIKE II 3108 8-port SAS 12G HW RAID card
Onboard I/O
Connectors
TPM Header 1
PSU Connector 24-pin SSI power connector + 2 x 8-pin SSI 12V
Management
Connector Onboard ASMB9-iKVM
Fan Header 8 x 4 pin
SMBus 1
Chassis Intruder 1
Front LAN LED 4
Serial Port Header 1
M.2 Connector 2 (NGFF Type 22110)
Micro SD card 1
VROC Key Header 1
OCuLink
Connector 2 (PCIe Gen3 x4) from CPU1
Rear I/O
Connectors
External USB Port 4 x USB 3.0
VGA Port 1
RJ-45 4 x GbE LAN
1 x Management LAN
Management
Solution
Out of Band
Remote
Management
ASMB9-iKVM for KVM-over-Internet
Monitoring CPU Temperature
FAN RPM
Environment
Operating temperature: 10°C ~ 35°C
Non operating temperature: -40°C ~ 70°C
Non operating humidity: 20% ~ 90% (Non condensing)
* Specications are subject to change without notice.
** Refer to www.asus.com for the complete list of supported PIKE cards.
1
Product Introduction
This chapter describes the motherboard features and the new
technologies it supports.
Chapter 1: Product Introduction
1-2 Chapter 1: Product Introduction
1.1 Welcome!
Congratulations and thank you for buying an ASUS® Z11PA-D8 Series motherboard!
The motherboard delivers a host of new features and latest technologies, making it another
standout in the long line of ASUS quality motherboards!
Before you start installing the motherboard and hardware devices on it, check the items in
your package with the list below.
1.2 Package contents
Check your motherboard package for the following items.
If any of the above items is damaged or missing, contact your retailer.
Standard Gift Box Pack Standard Bulk Pack
I/O Shield 1 1
Application CD Support DVD 1 1 piece per carton
Packaging Quantity 1 piece per carton 10 pieces per carton
Optional items Description
PIKE 3008 LSI 8-port SAS 12G RAID card
PIKE 3108 LSI 8-port SAS 12G HW RAID card
ASMB9-iKVM Remote management solution provides KVM over IP solution
PEM-FDR Mellanox ConnectX-3 FDR card
PEB-10G/57840-2S Dual port 10G SFP+ Ethernet Adapter
PEB-10G/57811-1S Single port 10G SFP+ Ethernet Adapter
PEI-10G/82599-2S 10GbE SFP+ Network Adapter
The ASUS PIKE 3008, PIKE 3108, and PEM-FDR cards must be installed on PCI-E slot
2/3/4/5.
Z11PA-D8 Series 1-3
1.4 Special features
1.4.1 Product highlights
Latest Processor Technology
The motherboard supports Intel® Xeon® Scalable processor family which provides compelling
IPC increases for legacy performance improvements, oating point improvement, easier
multi-core programming, and with next-generation processor power management. Intel®
Xeon® Scalable processor family also improve the I/O capabilities and support UPI link speed
of up to 10.4GT/s.
Intel® AVX 512
Intel® AVX 2.0 extends 512-bit vector support for integer vector operations, doubles
xed point arithmetic throughput, adds support for new vector gather, permutes/blend,
vector shifts resulting in xed and oating-point algorithm improvements. Also, Intel's new
microarchitecture doubles the cache bandwidth at L1/L2 to support higher FLOPS and
contributes to greater performance in signal and image processing applications.
Next Generation of processor power management
Intel® Xeon® Scalable processor family enhances the processor power management with the
features of Energy Efcient Turbo, Uncore Frequency Scaling, and Per-Core P-state. Also,
the Integrated Voltage Regulator enables generational performance and power improvements
that the standard VR solutions cannot provide.
DDR4 memory support
The motherboard supports DDR4 memory that features faster clock frequencies and higher
data transfer rates of 2133 MT/s to 2666 MT/s (million transfers per second). DDR4 offers a
lower voltage standard of 1.2V that reduces memory power demand and provides improved
performance.
1.3 Serial number label
Before requesting support from the ASUS Technical Support team, you must take note of
the motherboard's serial number containing 12 characters xxS2xxxxxxxx shown in the gure
below. With the correct serial number of the product, ASUS Technical Support team members
can then offer a quicker and satisfying solution to your problems.
xxS2xxxxxxxx
Z11PA-D8 Series Made
in
China
合格
1-4 Chapter 1: Product Introduction
M.2 Support
This motherboard features the M.2 slot, which shares bandwidth with the SATA 6Gb/s port
and PCI-E Gen3 x4 and is dedicated to the operating system.
PCI Express 3.0
PCI Express 3.0 (PCIe 3.0) is the PCI Express bus standard that provides twice the
performance and speed of PCIe 2.0. It provides an optimal graphics performance,
unprecedented data speed, and seamless transition with its complete backward compatibility
to PCIe 2.0 devices.
Intel® I210AT LAN Solution
The motherboard comes with four Gigabit LAN controllers and ports which provide a total
solution for your networking needs. The onboard Intel® I210AT Gigabit LAN controllers use
the PCI Express interface and could achieve network throughput close to Gigabit bandwidth.
Intel® C621 Series Chipset
The Intel® C621 series chipset supports with enterprise class features which is targeted for
Cloud and Storage applications. It is optimized and validated to work with the latest Intel®
Xeon® Scalable processor family, compared with the last generation, it also reduces the TDP,
supports USB 3.0 with up to 12 SATA III ports thus bringing more features and benets to the
target users.
Serial ATA III technology
The motherboard supports the Serial ATA III technology through the Serial ATA interface
and Intel® 621 chipset, delivering up to 6 Gb/s data transfer rates. It also provides enhanced
scalability, faster data retrieval, and double the bandwidth of current bus systems.
Temperature, fan, and voltage monitoring
The CPU temperature is monitored to prevent overheating and damage. The system fan
rotations per minute (RPM) is monitored for timely failure detection. The chip monitors the
voltage levels to ensure a stable supply of current for critical components.
1.4.2 Innovative ASUS features
ASUS Fan Speed control technology
The ASUS Fan Speed control technology smartly adjusts the fan speeds according to the
system loading to ensure a quiet, cool, and efcient operation.
2
Hardware Information
This chapter lists the hardware setup procedures that you have
to perform when installing system components. It includes
description of the jumpers and connectors on the motherboard.
Chapter 2: Hardware Information
2-2 Chapter 2: Hardware Information
2.1 Before you proceed
Take note of the following precautions before you install any motherboard component or
change any motherboard settings.
• Unplugthepowercordfromthewallsocketbeforetouchinganycomponent.
• Useagroundedwriststraportouchasafelygroundedobjectorametalobject,such
asthepowersupplycase,beforehandlingcomponentstoavoiddamagingthemdue
to static electricity.
• HoldcomponentsbytheedgestoavoidtouchingtheICsonthem.
• Wheneveryouuninstallanycomponent,placeitonagroundedantistaticpadorinthe
bag that came with the component.
• Beforeyouinstallorremoveanycomponent,ensurethatthepowersupplyisswitched
off or the power cord is detached from the power supply. Failure to do so may cause
severedamagetothemotherboard,peripherals,and/orcomponents.
2-3
Z11PA-D8 Series
2.2 Motherboard overview
Beforeyouinstallthemotherboard,studythecongurationofyourchassistoensurethatthe
motherboardtsintoit.
Tooptimizethefeaturesofyourmotherboard,wehighlyrecommendthatyouinstallitinan
ATX 2.2 compliant chassis.
2.2.1 Placement direction
Wheninstallingthemotherboard,ensurethatyouplaceitintothechassisinthecorrect
orientation. The edge with external ports goes to the rear part of the chassis as indicated in
the image below.
2.2.2 Screw holes
Place nine (9) screws into the holes indicated by circles to secure the motherboard to the
chassis.
DO NOT overtighten the screws! Doing so can damage the motherboard.
Ensure to unplug the chassis power cord before installing or removing the motherboard.
Failure to do so can cause you physical injury and damage motherboard components!
Place this side towards
the rear of the chassis
2-4 Chapter 2: Hardware Information
2.2.3 Motherboard layout
2-5
Z11PA-D8 Series
Layout contents
Internal connectors / Sockets / Jumpers / LEDs Page
1. DDR4 DIMM sockets 2-8
2. CPU,front,andrearfanconnectors(4-pinCPU_FAN1-2;FRNT_FAN1-4;
REAR_FAN1-2) 2-28
3. PowerSupplySMBusconnector(5-pinPSUSMB1) 2-26
4. PMBus1.2PSUselectjumper(3-pinSMART_PSU1) 2-17
5. EATXpowerconnectors(24-pinEATXPWR1;8-pinEATX12V1-2) 2-30
6. CPUsocket 2-6
7. Mini-SASHDconnector(ISATA1-2;ISSATA1;MVSATA1) 2-25
8. VPP_I2C1connector(10-1pinVPP_I2C1) 2-34
9. OCUPCIEconnectors(OCUPCIE1-2) 2-34
10. VROCKEYconnector(4-pinVROC_KEY1) 2-29
11. ChassisIntrusion(2-pinINTRUSION1) 2-33
12. LANActivityLEDconnector(5-1pinLAN34_LED1) 2-35
13. System panel connector (20-1 pin PANEL1) 2-31
14. Auxiliarypanelconnector(20-2pinAUX_PANEL1,20-1pinAUX_PANEL2) 2-32
15. USB3.0connector(20-1pinUSB3_12) 2-27
16. BaseboardManagementControllersetting(3-pinBMC_EN1) 2-18
17. VGAcontrollersetting(3-pinVGA_SW1) 2-15
18. PCH_MFG1setting(3-pinPCH_MFG1) 2-19
19. MErmwareforcerecoverysetting(3-pinME_RCVR1) 2-16
20. SystemManagementBus(SMBUS)connector(5-1pinSMBUS1) 2-35
21. USB2.0connector(10-1pinUSB78) 2-27
22. DDR4 thermal event setting (3-pin DIMMTRIP1-2) 2-16
23. Trusted Platform Module connector (14-1 pin TPM1) 2-29
24. IPMISWsetting(3-pinIPMI_SW1) 2-18
25. DMLANsetting(3-pinDM_IP_EN1) 2-17
26. ClearRTCRAM(3-pinCLRTC1) 2-14
27. Q-CodeLEDs(PORT80_LED1) 2-23
28. HarddiskactivityLEDconnector(4-pinHDLED1) 2-33
29. Serialportconnector(10-1pinCOM1) 2-28
30. LANcontrollersetting(3-pinLAN_SW1-4) 2-15
31. Micro SD card slot (MSD1) 2-25
32. M.2(NGFF)connector(NGFF1-2) 2-26
2-6 Chapter 2: Hardware Information
2.3.1 Installing the CPU
ToinstallaCPU:
1. LocatetheCPUsocketonthemotherboard.
2.3 Central Processing Unit (CPU)
ThemotherboardcomeswithasurfacemountLGA3647socketdesignedfortheIntel®
Xeon® Processor Scalable Family Series.
• Uponpurchaseofthemotherboard,ensurethatthePnPcapisonthesocketand
thesocketcontactsarenotbent.ContactyourretailerimmediatelyifthePnPcap
ismissing,orifyouseeanydamagetothePnPcap/socketcontacts/motherboard
components.ASUSwillshoulderthecostofrepaironlyifthedamageisshipment/
transit-related.
• Keepthecapafterinstallingthemotherboard.ASUSwillprocessReturnMerchandise
Authorization(RMA)requestsonlyifthemotherboardcomeswiththecapontheLGA
3647 socket.
• Theproductwarrantydoesnotcoverdamagetothesocketcontactsresultingfrom
incorrectCPUinstallation/removal,ormisplacement/loss/incorrectremovalofthePnP
cap.
2. RemovethePnPcapsfromtheCPUsockets.
2-7
Z11PA-D8 Series
3. AlignthetrianglemarkontheCPUwith
thetrianglemarkontheCPUCarrier
(A),theninstalltheCPUintotheCPU
Carrieruntilitclicksrmlyintoplace(B),
andtheninstalltheCPUCarrierintothe
heatsinkuntilitclicksrmlyinplace(C).
Ensure that the triangle mark on the
CPUmatchesthetrianglemarkon
theCPUCarrier.
CPU Carrier
2
CPU
Triangle mark
4. AligntheCPUandCPUCarrierinthecorrectorientation,andthenplacetheheatsinks
ontopoftheCPUsockets.
TheCPUandCPUCarriertsinonlyonecorrectorientation.DONOTforcetheCPUand
CPUCarrierintothesockettopreventdamagingtheCPUpinsonthesocket.
5. Twist each of the four screws with a screwdriver just enough to attach the heatsink to
themotherboard.Whenthefourscrewsareattached,tightenthemonebyoneina
diagonal sequence to completely secure the heatsink.
The heatsink screws are T30 models. A torque value of 12 inch-lbf is recommended.
2-8 Chapter 2: Hardware Information
2.4 System memory
2.4.1 Overview
The motherboard comes with eight (8) Double Data Rate 4 (DDR4) Dual Inline Memory
Modules (DIMM) sockets.
ThegureillustratesthelocationoftheDDR4DIMMsockets:
2.4.2 MemoryCongurations
Youmayinstall4GB,8GB,16GB,and32GBRDIMMsor32GBand64GBLR-DIMMsinto
theDIMMsocketsusingthememorycongurationsinthissection.
• RefertoASUSServerAVLfortheupdatedlistofcompatibleDIMMs.
• WheninstallingDIMMs,alwaysstartfromslotA1(CPU1)andG1(CPU2).
• AlwaysinstallDIMMswiththesameCASlatency.Foroptimumcompatibility,itis
recommended that you obtain memory modules from the same vendor.
2-9
Z11PA-D8 Series
SingleCPUconguration(mustbeinstalledonCPU1)
DIMM
A1 B1 D1 E1
1 DIMM P
2 DIMMs P P
4 DIMMs P P P P
DualCPUconguration
YoucanrefertothefollowingrecommendedmemorypopulationforadualCPUconguration.
SingleCPUconguration
YoucanrefertothefollowingrecommendedmemorypopulationforasingleCPU
conguration.
DualCPUconguration
DIMM
A1 B1 D1 E1 G1 H1 K1 L1
2 DIMMs P P
4 DIMMs P P P P
8 DIMMs P P P P P P P P
2-10 Chapter 2: Hardware Information
1CPUConguration(mustbeonCPU1)
Modes DIMM_A1 DIMM_B1 DIMM_D1 DIMM_E1
AD DRAM DCPMM DRAM DCPMM
MM DRAM DCPMM DRAM DCPMM
AD+MM DRAM DCPMM DRAM DCPMM
2CPUConguration
Modes DIMM_A1 DIMM_B1 DIMM_D1 DIMM_E1
AD DRAM DCPMM DRAM DCPMM
MM DRAM DCPMM DRAM DCPMM
AD+MM DRAM DCPMM DRAM DCPMM
2CPUConguration
Modes DIMM_G1 DIMM_H1 DIMM_K1 DIMM_L1
AD DRAM DCPMM DRAM DCPMM
MM DRAM DCPMM DRAM DCPMM
AD+MM DRAM DCPMM DRAM DCPMM
AD - APP DIRECT MODE
MM - MEMORY MODE
AD+MM - MIXED MODE
DCPMM - DC PERSISTENT MEMORY
Intel® DC persistent memory population table
1CPUConguration
2CPUConguration
2-11
Z11PA-D8 Series
2.4.3 Installing a DIMM on a single clip DIMM socket
Ensure to unplug the power supply before adding or removing DIMMs or other system
components. Failure to do so may cause severe damage to both the motherboard and the
components.
3. HoldtheDIMMbybothofitsends
then insert the DIMM vertically into the
socket. Apply force to both ends of the
DIMM simultaneously until the retaining
clip snaps back into place and the
DIMM cannot be pushed in any further
to ensure proper sitting of the DIMM.
Locked Retaining Clip
1. UnlockaDIMMsocketbypressingthe
retaining clip outward.
2. Align a DIMM on the socket such that
the notch on the DIMM matches the
DIMM slot key on the socket.
Unlocked retaining clip
DIMM notch
DIMM slot key
1. Press the retaining clip outward to
unlock the DIMM.
2. Remove the DIMM from the socket.
2.4.4 Removing a DIMM from a single clip DIMM socket
SupporttheDIMMlightlywithyourngerswhenpressingtheretainingclips.TheDIMM
mightgetdamagedwhenitipsoutwithextraforce.
Always insert the DIMM into the socket vertically to prevent DIMM notch damage.
ADIMMiskeyedwithanotchsothatittsinonlyonedirection.DONOTforceaDIMMinto
a socket in the wrong direction to avoid damaging the DIMM.
2-12 Chapter 2: Hardware Information
2.5 Expansion slots
Inthefuture,youmayneedtoinstallexpansioncards.Thefollowingsubsectionsdescribethe
slots and the expansion cards that they support.
2.5.1 Installing an expansion card
Toinstallanexpansioncard:
1. Beforeinstallingtheexpansioncard,readthedocumentationthatcamewithitand
make the necessary hardware settings for the card.
2. Remove the system unit cover (if your motherboard is already installed in a chassis).
3. Removethebracketoppositetheslotthatyouintendtouse.Keepthescrewforlater
use.
4. Alignthecardconnectorwiththeslotandpressrmlyuntilthecardiscompletely
seated on the slot.
5. Secure the card to the chassis with the screw you removed earlier.
6. Replace the system cover.
2.5.2 Conguringanexpansioncard
Afterinstallingtheexpansioncard,congureitbyadjustingthesoftwaresettings.
1. TurnonthesystemandchangethenecessaryBIOSsettings,ifany.SeeChapter 4 for
informationonBIOSsetup.
2. Assign an IRQ to the card.
Refer to the table Standard Interrupt assignments in section Interrupt assignments for
more information.
3. Install the software drivers for the expansion card.
Ensure to unplug the power cord before adding or removing expansion cards. Failure to do
so may cause you physical injury and damage motherboard components.
WhenusingPCIcardsonsharedslots,ensurethatthedriverssupport“ShareIRQ”orthat
thecardsdonotneedIRQassignments.Otherwise,conictsmayarisebetweenthetwo
PCIgroups,makingthesystemunstableandthecardinoperable.
2-13
Z11PA-D8 Series
*TheseIRQsareusuallyavailableforISAorPCIdevices.
IRQ Priority Standard function
0 1 System Timer
1 2 KeyboardController
2 - Programmable Interrupt
3* 11 CommunicationsPort(COM2)
4* 12 CommunicationsPort(COM1)
5* 13 --
6 14 FloppyDiskController
7* 15 --
8 3 SystemCMOS/RealTimeClock
9* 4 ACPIModewhenused
10* 5 IRQHolderforPCISteering
11* 6 IRQHolderforPCISteering
12* 7 PS/2CompatibleMousePort
13 8 Numeric Data Processor
14* 9 PrimaryIDEChannel
15* 10 SecondaryIDEChannel
2.5.3 Interrupt assignments
Standard Interrupt assignments
2.5.4 PCI Express x16 slot (x16 link)
TheonboardPCIE3andPCIE5slotsprovidesonex16Gen3linktoCPU1.Thisslotsupports
VGAcardsandvariousserverclasshighperformanceadd-oncards.
2.5.5 PCI Express x8 slot (x8 link)
TheonboardPCIE1slotprovidesonex8Gen3linktoCPU2.TheseslotssupportVGAcards
and various server class high performance add-on cards.
2-14 Chapter 2: Hardware Information
No. (Slot location) Short description
1PCIE6 MIO
2PCIE5 PCI-Ex16(x16Gen3Link)
3PCIE3 PCI-Ex16(x16Gen3Link)
4PCIE1 PCI-Ex8(x8Gen3Link)
2-15
Z11PA-D8 Series
2.6 Jumpers
1. Clear RTC RAM (3-pin CLRTC1)
ThisjumperallowsyoutocleartheRealTimeClock(RTC)RAMinCMOS.Youcan
cleartheCMOSmemoryofdate,time,andsystemsetupparametersbyerasingthe
CMOSRTCRAMdata.TheonboardbuttoncellbatterypowerstheRAMdatainCMOS
which include system setup information such as system passwords.
ToerasetheRTCRAM:
1. Turn OFF the computer and unplug the power cord.
2. Movethejumpercapfromthedefaultpins1–2topins2–3.Keepthecaponpins
2–3forabout5to10seconds,thenmovethecapbacktopins1–2.
3. Plug the power cord and turn ON the computer.
4. Holddownthe<Del>keyduringthebootprocessandenterBIOSsetuptore-
enter data.
DONOTremovethecaponCLRTCjumperdefaultpositionexceptwhenclearingtheRTC
RAM. Removing the cap will cause system boot failure!
Ifthestepsabovedonothelp,removetheonboardbatteryandmovethejumperagainto
cleartheCMOSRTCRAMdata.AftertheCMOSclearance,reinstallthebattery.
2-16 Chapter 2: Hardware Information
2. VGA controller setting (3-pin VGA_SW1)
ThisjumperallowsyoutoenableordisabletheonboardVGAcontroller.Settopins1–2
toactivatetheVGAfeature.
3. LAN controller setting (3-pin LAN_SW1-4)
ThesejumpersallowyoutoenableordisabletheonboardLAN_SW1-4.Settopins1-2
toactivatetheGigabitLANfeature.
2-17
Z11PA-D8 Series
4. MErmwareforcerecoverysetting(3-pinME_RCVR1)
This jumper allows you to force Intel® Management Engine (ME) boot from recovery
mode when ME becomes corrupted.
5. DDR4 thermal event setting (3-pin DIMMTRIP1-2)
This jumper allows you to enable or disable DDR4 DIMM thermal sensing event pin.
2-18 Chapter 2: Hardware Information
6. PMBus 1.2 PSU select jumper (3-pin SMART_PSU1)
ThisjumperallowsyoutoselectPSUPMBusversion.Settopins1–2forPMBus,set
to pins 2–3 for others.
7. DMLAN setting (3-pin DM_IP_EN1)
This jumper allows you to select the DMLAN setting. Set to pins 2-3 to force the
DMLANIPtostaticmode(IP=10.10.10.10,submask=255.255.255.0).
2-19
Z11PA-D8 Series
8. IPMI SW setting (3-pin IPMI_SW1)
ThisjumperallowsyoutoselectwhichprotocolintheGPUsensortofunction.
9. Baseboard Management Controller setting (3-pin BMC_EN1)
Thisjumperallowsyoutoenable(default)ordisableon-boardBMC.Ensuretosetthis
BMCjumpertoenabledtoavoidsystemfancontrolandhardwaremonitorerror.
2-20 Chapter 2: Hardware Information
10. PCH_MFG1 setting (3-pin PCH_MFG1)
ThisjumperallowsyoutoupdatetheBIOSMEblock.
2-21
Z11PA-D8 Series
2. BMC LED (BMCLED1)
TheBMCLEDblinkstoindicatethattheon-boardBMCisfunctional.
2.7 Onboard LEDs
1. Standby Power LED (SB_PWR1)
The motherboard comes with a standby power LED. The green LED lights up to
indicatethatthesystemisON,insleepmode,orinsoft-offmode.Thisisareminder
that you should shut down the system and unplug the power cable before removing or
plugging in any motherboard component. The illustration below shows the location of
the onboard LED.
2-22 Chapter 2: Hardware Information
3. Storage device activity LED (HDDLED1)
ThisLEDisforthestoragedevicesconnectedtotheonboardSATA,orSATA/SAS
add-oncard.ThereadorwriteactivitiesofanydeviceconnectedtotheonboardSATA,
orSATA/SASadd-oncardcausestherearpanelLEDtolightup.
4. Location LED (LOCLED1)
This onboard LED lights up when the Location button on the server is pressed or when
triggered by a system management software. The Location LED helps visually locate
and quickly identify the server in error on a server rack.
2-23
Z11PA-D8 Series
5. Message LED (MESLED1)
ThisonboardLEDlightsuptoredwhenthereisaBMCeventlogisgenerated.
6. CATT LED (CATTERR_LED1)
TheCATTLEDindicatesthatthesystemhasexperiencedafatalorcatastrophicerror
and cannot continue to operate.
2-24 Chapter 2: Hardware Information
7. Q-Code LEDs (PORT80_LED1)
TheQ-CodeLEDdesignprovidesyouwitha2-digiterrorcodethatdisplaysthesystem
status.
• TheQ-CodeLEDsprovidethemostprobablecauseofanerrorcodeasastarting
point for troubleshooting. The actual cause may vary from case to case.
• PleaserefertotheQ-CodetableintheAppendix section for more details.
2-25
Z11PA-D8 Series
2.8 Connectors
2.8.1 Rear panel connectors
1. RJ-45portforiKVM.ThisRJ-45portfunctionsonlywhenyouenableASMB9controller.
2. VideoGraphicsAdapter(VGA)port.ThisportisforaVGAmonitororotherVGA-
compatible devices.
3. RJ-45ports1and2forLAN.TheseportsallowsGigabitconnectiontoaLANthrougha
network hub. Refer to the LAN port LED indications table for more information.
4. RJ-45ports3and4forLAN.TheseportsallowsGigabitconnectiontoaLANthrougha
network hub. Refer to the LAN port LED indications table for more information.
5. Power-onButton.Pressthisbuttontoturnonthesystem.
6. USB3.0ports3and4.Thesetwo4-pinUniversalSerialBus(USB)portsareavailable
forconnectingUSB3.0devices.
7. USB3.0ports5and6.Thesetwo4-pinUniversalSerialBus(USB)portsareavailable
forconnectingUSB3.0devices.
LAN port LED indications
Activity/Link LED Speed LED
Status Description Status Description
OFF No link OFF 10 Mbps connection
GREEN Linked ORANGE 100 Mbps connection
BLINKING Data activity GREEN 1Gbpsconnection
SPEED
LED
ACT/LINK
LED
Activity/Link LED Speed LED
Status Description Status Description
OFF No link OFF 10 Mbps connection
ORANGE Linked ORANGE 100 Mbps connection
BLINKING Data activity GREEN 1Gbpsconnection
Management LAN port LED indications
LAN port 1-4
SPEED
LED
ACT/LINK
LED
SPEED
LED
ACT/LINK
LED
2-26 Chapter 2: Hardware Information
2.8.2 Internal connectors
1. Mini-SAS HD connector (ISATA1-2; ISSATA1; MVSATA1)
ThismotherboardcomeswithminiSerialAttachedSCSI(SAS)HDconnectors,the
storage technology that supports Serial ATA. Each connector supports up to four
devices.
2. Micro SD card slot (MSD1)
YourmotherboardsupportsSDMemoryCardv2.00(SDHC)/v3.00(SDXC).
Some memory cards may not be compatible with your motherboard. Ensure that you use
onlycompatiblememorycardstopreventlossofdata,damagetoyourdevice,ormemory
card,orboth.
Disconnectallpower(includingredundantPSUs)fromtheexistingsystembeforeyouadd
orremoveaMemoryCard,thenrebootthesystemtoaccesstheMemoryCard.
2-27
Z11PA-D8 Series
3. Power Supply SMBus connector (5-pin PSUSMB1)
ThisconnectorallowsyoutoconnectSMBus(SystemManagementBus)tothePSU
(powersupplyunit)toreadPSUinformation.DevicescommunicatewithanSMBus
hostand/orotherSMBusdevicesusingtheSMBusinterface.
ThisconnectorfunctionsonlywhenyouinstalltheASUSASMB8.
PowersupplyisrequiredtomeetPMBusspecicationandcustomizedBMCFWmaybe
needed.PleasecontactASUSifyourneedfurthersupport.
4. M.2 (NGFF) connector (NGFF1-2)
These connectors allow you to install M.2 devices.
Thisconnectorsupportstype22110devicesonbothPCI-EandSATAinterface.
TheM.2(NGFF)deviceispurchasedseparately.
2-28 Chapter 2: Hardware Information
5. USB 2.0 connector (10-1 pin USB78)
ThisconnectorisforUSB2.0ports.ConnecttheUSBmodulecabletotheconnector,
and then install the module to a slot opening at the back of the system chassis. The
USBconnectorscomplywithUSB2.0specicationthatsupportsupto480Mbps
connection speed.
6. USB 3.0 connector (20-1 pin USB3_12)
ThisconnectorallowsyoutoconnectaUSB3.0moduleforadditionalUSB3.0front
orrearpanelports.WithaninstalledUSB3.0module,youcanenjoyallthebenetsof
USB3.0includingfasterdatatransferspeedsofupto5Gbps,fasterchargingtimefor
USB-chargeabledevices,optimizedpowerefciency,andbackwardcompatibilitywith
USB2.0.
2-29
Z11PA-D8 Series
7. CPU, front, and rear fan connectors (4-pin CPU_FAN1-2; FRNT_FAN1-4;
REAR_FAN1-2)
Thefanconnectorssupportcoolingfans.Connectthefancablestothefanconnectors
onthemotherboard,ensuringthattheblackwireofeachcablematchesthegroundpin
of the connector.
• DONOTforgettoconnectthefancablestothefanconnectors.Insufcientairow
inside the system may damage the motherboard components.
• Thesearenotjumpers!DONOTplacejumpercapsonthefanconnectors!
• AllfansfeaturetheASUSSmartFantechnology.
8. Serial port connector (10-1 pin COM1)
ThisconnectorisfortheserialCOMport.Connecttheserialportmodulecabletoone
oftheseconnectors,theninstallthemoduletoaslotopeningatthebackofthesystem
chassis.
2-30 Chapter 2: Hardware Information
9. Trusted Platform Module connector (14-1 pin TPM1)
ThisconnectorsupportsaTrustedPlatformModule(TPM)system,whichcansecurely
storekeys,digitalcerticates,passwords,anddata.ATPMsystemalsohelpsenhance
networksecurity,protectsdigitalidentities,andensuresplatformintegrity.
10. VROC KEY connector (4-pin VROC_KEY1)
ThisconnectorallowsyoutoconnectaKEYmoduletoenableadditionalCPURAID
functions with Intel®CPURSTe.
TheKEYmoduleispurchasedseparately.
2-31
Z11PA-D8 Series
11. EATX power connectors (24-pin EATXPWR1; 8-pin EATX12V1-2)
These connectors are for the SSI or ATX power supply plugs. The power supply plugs
aredesignedtottheseconnectorsinonlyoneorientation.Findtheproperorientation
andpushdownrmlyuntiltheconnectorscompletelyt.
• DONOTforgettoconnectthe24+8-pinpowerplugswhenusing85WorbelowCPU;
otherwise,thesystemwillnotbootup.
• DONOTforgettoconnectthe24+8+8-pinpowerplugswhenusing105Worabove
CPU;otherwise,thesystemwillnotbootup.
• UseofaPSUwithahigherpoweroutputisrecommendedwhenconguringasystem
with more power-consuming devices. The system may become unstable or may not
boot up if the power is inadequate.
• Ensurethatyourpowersupplyunit(PSU)canprovideatleasttheminimumpower
requiredbyyoursystem.MinimumrequirementofATXpowersupply1)500W2)
All+12Voutput>20A.
2-32 Chapter 2: Hardware Information
12. System panel connector (20-1 pin PANEL1)
This connector supports several chassis-mounted functions.
1. System power LED (3-pin PLED)
This3-pinconnectorisforthesystempowerLED.Connectthechassispower
LED cable to this connector. The system power LED lights up when you turn on
thesystempower,andblinkswhenthesystemisinsleepmode.
2. Message LED (2-pin MLED)
This 2-pin connector is for the message LED cable that connects to the front
messageLED.ThemessageLEDiscontrolledbyHardwaremonitortoindicate
an abnormal event occurrence.
3. System warning speaker (4-pin SPEAKER)
This 4-pin connector is for the chassis-mounted system warning speaker. The
speaker allows you to hear system beeps and warnings.
4. Hard disk drive activity LED (2-pin HDD LED)
This2-pinconnectorisfortheHDDActivityLED.ConnecttheHDDActivityLED
cabletothisconnector.TheHDDLEDlightsuporasheswhendataisreadfrom
orwrittentotheHDD.
5. Power button/soft-off button (2-pin PWRSW)
This connector is for the system power button. Pressing the power button turns
thesystemonorputsthesysteminsleeporsoft-offmodedependingontheBIOS
settings. Pressing the power switch for more than four seconds while the system
is ON turns the system OFF.
6. Reset button (2-pin RESET)
This 2-pin connector is for the chassis-mounted reset button for system reboot
without turning off the system power.
2-33
Z11PA-D8 Series
13. Auxiliary panel connector (20-2 pin AUX_PANEL1, 20-1 pin AUX_PANEL2)
ThisconnectorisforadditionalfrontpanelfeaturesincludingfrontpanelSMB,locator
LEDandswitch,chassisintrusion,andLANLEDs.
1. Front panel SMB (6-1 pin FPSMB)
This6-1pinconnectorisforthefrontpanelSMBuscable.
2. LAN activity LED (2-pin LAN1_LED, LAN2_LED)
This2-pinconnectorisfortheGigabitLANactivityLEDsonthefrontpanel.
3. Locator LED (2-pin LOCATORLED1, 2-pin LOCATORLED2)
This2-pinconnectorisforthelocatorLED1andLED2onthefrontpanel.Connect
the Locator LED cables to these 2-pin connector. The LEDs will light up when the
Locator button is pressed.
4. Locator Button/Switch (2-pin LOCATORBTN)
This 2-pin connector is for the locator button on the front panel. This button
queries the state of the system locator.
5. LAN activity LED and USB port (2-pin LAN3_LED, LAN4_LED, USB ports)
TheseleadsarefortheGigabitLANactivityLEDsandUSBportsonthefront
panel.
2-34 Chapter 2: Hardware Information
14. Hard disk activity LED connector (4-pin HDLED1)
This LED connector is for the storage add-on card cable connected to the SATA or
SAS add-on card. The read or write activities of any device connected to the SATA or
SAS add-on card causes the front panel LED to light up.
15. Chassis Intrusion (2-pin INTRUSION1)
These leads are for the intrusion detection feature for chassis with intrusion sensor or
microswitch.Whenyouremoveanychassiscomponent,thesensortriggersandsends
a high level signal to these leads to record a chassis intrusion event. The default setting
isshortCHASSIS#andGNDpinbyjumpercaptodisablethefunction.
2-35
Z11PA-D8 Series
16. OCUPCIE connectors (OCUPCIE1-2)
TheOCUPCIEconnectorsallowsyoutoconnectNVMEstoragedevices.
17. VPP_I2C1 connector (10-1 pin VPP_I2C1)
ThisconnectorisusedfortheIntelVMDfunctionandsensorreadings.
2-36 Chapter 2: Hardware Information
18. LAN Activity LED connector (5-1 pin LAN34_LED1)
TheseleadsareforLANactivityLEDsonthefrontpanel.ConnecttheLANLEDcable
to the backplane for LAN activity indication.
19. System Management Bus (SMBUS) connector (5-1 pin SMBUS1)
This connector controls the system and power management-related tasks. This
connector processes the messages to and from devices rather than tripping the
individual control lines.
3
Powering Up
This chapter describes the power up sequence, and ways of
shutting down the system.
Chapter 3: Powering Up
3-2 Chapter 3: Powering Up
3.1 Startingupforthersttime
1. After making all the connections, replace the system case cover.
2. Be sure that all switches are off.
3. Connect the power cord to the power connector at the back of the system chassis.
4. Connect the power cord to a power outlet that is equipped with a surge protector.
5. Turn on the devices in the following order:
a. Monitor
b. External storage devices (starting with the last device on the chain)
c. System power
6. After applying power, the system power LED on the system front panel case lights up.
For systems with ATX power supplies, the system LED lights up when you press the
ATX power button. If your monitor complies with “green” standards or if it has a “power
standby” feature, the monitor LED may light up or switch between orange and green
after the system LED turns on.
The system then runs the power-on self-test or POST. While the tests are running, the
BIOS beeps or additional messages appear on the screen. If you do not see anything
within 30 seconds from the time you turned on the power, the system may have failed
a power-on test. Check the jumper settings and connections or call your retailer for
assistance.
The following shows the possible beep codes and its corresponding error condition
BIOSBeepcodes
Beep Error condition
1 short Power supply surges detected during the previous power on.
1 short No Keyboard Detected.
1 short, 2 short No DIMM Detected.
1 short, 8 short No VGA Detected.
2 long Chassis Intrusion.
2 long BIOS-image Crash Detected.
7. At power on, hold down the <Del> key to enter the BIOS Setup. Follow the instructions
in Chapter 4.
3-3
Z11PA-D8 Series
Pressing the power switch for more than four seconds lets the system enter the soft-off
mode regardless of the BIOS setting.
3.2 Poweringoffthecomputer
3.2.1 UsingtheOSshutdownfunction
UsingWindows® Server 2012 R2:
1. Press <Ctrl>+<Alt>+<Del>.
2. Click on the Power icon on the lower right side of the screen.
3. Select Shut down.
4. In the Shutdown Event Tracker, select the Other (Planned) option in the selection
list. Otherwise, select the option that best describes why you want to shut down the
computer.
5. Click Continue.
UsingWindows® Server 2016:
1. Press <Alt>+<F4>.
2. In the What do you want the computer to do?, select Shut down.
3. In the Shutdown Event Tracker, select the Other (Planned) option in the selection
list. Otherwise, select the option that best describes why you want to shut down the
computer.
4. Click OK.
3.2.2 Usingthedualfunctionpowerswitch
While the system is ON, press the power switch for less than four seconds to put the system
to sleep mode or to soft-off mode, depending on the BIOS setting.
3-4 Chapter 3: Powering Up
4
BIOS Setup
This chapter tells how to change the system settings through
the BIOS Setup menus. Detailed descriptions of the BIOS
parameters are also provided.
Chapter 4: BIOS Setup
4-2 Chapter 4: BIOS Setup
4.1 Managing and updating your BIOS
The following utilities allow you to manage and update the motherboard Basic Input/Output
System (BIOS) setup:
1. ASUS CrashFree BIOS 3
TorecovertheBIOSusingabootableUSBashdiskdrivewhentheBIOSlefailsor
gets corrupted.
2. ASUS EzFlash
UpdatestheBIOSusingaUSBashdisk.
3. BUPDATER
UpdatestheBIOSinDOSmodeusingabootableUSBashdiskdrive.
Refer to the corresponding sections for details on these utilities.
Recovering the BIOS from a USB ash drive
TorecovertheBIOSfromaUSBashdrive:
1. InserttheUSBashdrivewiththeoriginalorupdatedBIOSletooneUSBportonthe
system.
2. The utility will automatically recover the BIOS. It resets the system when the BIOS
recoverynished.
DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause
system boot failure!
The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the
ASUSwebsiteatwww.asus.comtodownloadthelatestBIOSle.
SaveacopyoftheoriginalmotherboardBIOSletoabootableUSBashdiskdrivein
case you need to restore the BIOS in the future. Copy the original motherboard BIOS using
the BUPDATER utility.
4.1.1 ASUS CrashFree BIOS 3 utility
TheASUSCrashFreeBIOS3isanautorecoverytoolthatallowsyoutorestoretheBIOSle
when it fails or gets corrupted during the updating process. You can update a corrupted BIOS
leusingaUSBashdrivethatcontainstheupdatedBIOSle.
PrepareaUSBashdrivecontainingtheupdatedmotherboardBIOSbeforeusingthis
utility.
4-3
Z11PA-D8 Series
3. Press <Tab> to switch to the Driveeld.
4. PresstheUp/DownarrowkeystondtheUSBashdiskthatcontainsthelatestBIOS,
then press <Enter>.
5. Press <Tab> to switch to the Folder Infoeld.
4.1.2 ASUS EZ Flash Utility
The ASUS EZ Flash Utility feature allows you to update the BIOS without having to use a
DOS-based utility.
Beforeyoustartusingthisutility,downloadthelatestBIOSfromtheASUSwebsiteat
www.asus.com.
To update the BIOS using EZ Flash Utility:
1. InserttheUSBashdiskthatcontainsthelatestBIOSleintotheUSBport.
2. Enter the BIOS setup program. Go to the Tool menu then select ASUS EZ Flash
Utility. Press <Enter>.
ASUS Tek. EzFlash Utility
[Up/Down/Left/Right]:Switch [Enter]:Choose [q]:Exit
FS0 System Volume Information <DIR>
Windows <DIR>
Z11PA-D8 BIOS <DIR>
Current Platform
Platform : Z11PA-D8
Version : 0020
Build Date :12/04/2016
New Platform
Platform : Z11PA-D8
Version : 0022
Build Date :01/01/2017
4-4 Chapter 4: BIOS Setup
6. PresstheUp/DownarrowkeystondtheBIOSle,andthenpress<Enter>toperform
the BIOS update process. Reboot the system when the update process is done.
• ThisfunctioncansupportdevicessuchasaUSBashdiskwithFAT32/16formatand
single partition only.
• DONOTshutdownorresetthesystemwhileupdatingtheBIOStopreventsystem
boot failure!
Ensure to load the BIOS default settings to ensure system compatibility and stability. Press
<F5> and select Yes to load the BIOS default settings.
4.1.3 BUPDATER utility
The succeeding BIOS screens are for reference only. The actual BIOS screen displays
may not be the same as shown.
TheBUPDATERutilityallowsyoutoupdatetheBIOSleintheDOSenvironmentusinga
bootableUSBashdiskdrivewiththeupdatedBIOSle.
Updating the BIOS le
ToupdatetheBIOSleusingtheBUPDATERutility:
1. Visit the ASUS website at www.asus.comanddownloadthelatestBIOSleforthe
motherboard.SavetheBIOSletoabootableUSBashdiskdrive.
2. Copy the BUPDATER utility (BUPDATER.exe) from the ASUS support website at
https://www.asus.com/supporttothebootableUSBashdiskdriveyoucreatedearlier.
3. BootthesysteminDOSmode,thenattheprompt,type:
BUPDATER /i[lename].CAP
where[lename]isthelatestortheoriginalBIOSleonthebootableUSBashdisk
drive,thenpress<Enter>.
A:\>BUPDATER /i[le name].CAP
4-5
Z11PA-D8 Series
4. Theutilityveriesthele,thenstartsupdatingtheBIOSle.
DO NOT shut down or reset the system while updating the BIOS to prevent system boot
failure!
5. The utility returns to the DOS prompt after the BIOS update process is completed.
Rebootthesystemfromtheharddiskdrive.
The BIOS update is nished! Please restart your system.
C:\>
Current Platform
Platform : Z11PA-D8
Version : 0020
Build date: 12/04/2016
New Platform
Platform : Z11PA-D8
Version : 0022
Build date: 01/01/2017
ASUS Tek. EzFlash Utility
Start Programming Flash. DO NOT SHUTDOWN THE SYSTEM!!!
Write
75%
4-6 Chapter 4: BIOS Setup
4.2 BIOS setup program
Thismotherboardsupportsaprogrammablermwarechipthatyoucanupdateusingthe
provided utility described in section 4.1 Managing and updating your BIOS.
UsetheBIOSSetupprogramwhenyouareinstallingamotherboard,reconguringyour
system,orpromptedto“RunSetup.”Thissectionexplainshowtocongureyoursystem
using this utility.
EvenifyouarenotpromptedtousetheSetupprogram,youcanchangethecongurationof
yourcomputerinthefuture.Forexample,youcanenablethesecuritypasswordfeatureor
changethepowermanagementsettings.Thisrequiresyoutorecongureyoursystemusing
the BIOS Setup program so that the computer can recognize these changes and record them
intheCMOSRAMofthermwarechip.
ThermwarechiponthemotherboardstorestheSetuputility.Whenyoustartupthe
computer,thesystemprovidesyouwiththeopportunitytorunthisprogram.Press<Del>
duringthePower-OnSelf-Test(POST)toentertheSetuputility;otherwise,POSTcontinues
with its test routines.
IfyouwishtoenterSetupafterPOST,restartthesystembypressing<Ctrl>+<Alt>+<Delete>,
or by pressing the reset button on the system chassis. You can also restart by turning the
systemoffandthenbackon.Dothislastoptiononlyifthersttwofailed.
TheSetupprogramisdesignedtomakeitaseasytouseaspossible.Beingamenu-driven
program,itletsyouscrollthroughthevarioussub-menusandmakeyourselectionsfromthe
availableoptionsusingthenavigationkeys.
• ThedefaultBIOSsettingsforthismotherboardapplyformostconditionstoensure
optimum performance. If the system becomes unstable after changing any BIOS
settings,loadthedefaultsettingstoensuresystemcompatibilityandstability.Press
<F5> and select Yes to load the BIOS default settings.
• TheBIOSsetupscreensshowninthissectionareforreferencepurposesonly,and
may not exactly match what you see on your screen.
• VisittheASUSwebsite(www.asus.com)todownloadthelatestBIOSleforthis
motherboard.
4-7
Z11PA-D8 Series
4.2.2 Menu bar
The menu bar on top of the screen has the following main items:
Main Forchangingthebasicsystemconguration
Performance Tuning For changing the performance settings
Advanced For changing the advanced system settings
Platform Conguration For changing the platform settings
Socket Conguration Forchangingthesocketsettings
Event Logs For changing the event log settings
Server Mgmt For changing the Server Mgmt settings
Security For changing the security settings
Boot Forchangingthesystembootconguration
Tool Forconguringoptionsforspecialfunctions
Save & Exit For selecting the exit options
Toselectanitemonthemenubar,presstherightorleftarrowkeyonthekeyboarduntilthe
desired item is highlighted.
4.2.1 BIOS menu screen
Navigation keys
General helpMenu bar Conguration eldsMenu items
4-8 Chapter 4: BIOS Setup
4.2.3 Menu items
Thehighlighteditemonthemenubardisplaysthespecicitemsforthatmenu.Forexample,
selecting Main shows the Main menu items.
The other items (such as Advanced) on the menu bar have their respective menu items.
4.2.4 Submenu items
A solid triangle before each item on any menu screen means that the item has a submenu.
Todisplaythesubmenu,selecttheitemthenpress<Enter>.
4.2.5 Navigation keys
AtthebottomrightcornerofamenuscreenarethenavigationkeysfortheBIOSsetup
program.Usethenavigationkeystoselectitemsinthemenuandchangethesettings.
4.2.6 General help
At the top right corner of the menu screen is a brief description of the selected item.
4.2.7 Conguration elds
Theseeldsshowthevaluesforthemenuitems.Ifanitemisuser-congurable,youcan
changethevalueoftheeldoppositetheitem.Youcannotselectanitemthatisnotuser-
congurable.
Acongurableeldisenclosedinbrackets,andishighlightedwhenselected.Tochangethe
valueofaeld,selectitandpress<Enter>todisplayalistofoptions.
4.2.8 Pop-up window
Selectamenuitemandpress<Enter>todisplayapop-upwindowwiththeconguration
options for that item.
4.2.9 Scroll bar
Ascrollbarappearsontherightsideofamenuscreenwhenthereareitemsthatdonott
onthescreen.PresstheUp/Downarrowkeysor<PageUp>/<PageDown>keystodisplay
the other items on the screen.
4-9
Z11PA-D8 Series
4.3 Main menu
WhenyouentertheBIOSSetupprogram,theMainmenuscreenappears.TheMainmenu
providesyouanoverviewofthebasicsysteminformation,andallowsyoutosetthesystem
date,time,language,andsecuritysettings.
4.3.1 System Date [Day xx/xx/xxxx]
Allows you to set the system date.
4.3.2 System Time [xx:xx:xx]
Allows you to set the system time.
4-10 Chapter 4: BIOS Setup
4.4 Performance Tuning menu
The Performance Tuning menu items allow you to change performance related settings for
different scenarios.
Optimized Performance Setting [Default]
Allows you to select performance settings for different scenarios.
[Default] Defaultsettings.
[ByBenchmark] Optimizefordifferentkindsofbenchmarks.Selectthisoption,thenselecta
benchmarktypefromthe>> list.
[ByWorkload] Optimizefordifferentkindsofworkloads.Selectthisoption,thenselecta
workloadtypefromthe>> list.
Congurationoptions:
[Peak Frequency Optimized] - Applies settings with performance and
power consumption balance. Recommended for users that need higher
performance.
[Latency Optimized] - Applies settings with low latency results.
Recommended for latency-sensitive users.
[Power Efcient Optimized]-Appliessettingswithpowerefciency.
Recommended for general users.
[HPC] - Applies settings with optimized compute capability. Recommend
for traditional HPC applications.
Core Optimizer and Engine Boost appear only when you set Optimized Performance
Setting to [Default] or [By Benchmark].
Core Optimizer [Disabled]
Enablethisitemtokeeptheprocessoroperatingattheturbofrequency.
Congurationoptions:[Disabled][Enabled]
Linux support may vary by version of the OS.
Engine Boost [Disabled]
Enable this item to boost the CPU's frequency.
Congurationoptions:[Disabled][Level1][Level2][Level3(Max)]
4-11
Z11PA-D8 Series
4.5 Advanced menu
The Advanced menu items allow you to change the settings for the CPU and other system
devices.
TakecautionwhenchangingthesettingsoftheAdvancedmenuitems.Incorrecteld
values can cause the system to malfunction.
Overclocking [Disabled]
EnablethisitemtoincreasetheCPU’sclock.
Congurationoptions:[Disabled][Level1][Level2][Level3(Max)]
Operate with an ambient temperature of 25°C or lower for optimized performance.
Pleasenotethatoverclockingmightcausecomponentdamageorsystemcrashes,which
mayreducethelifespanofthesystemandtheCPU.Usethistoolatyourownrisk.
Power Balancer [Disabled]
Select[EnableAuto]todynamicallyadjustthefrequencyofallCPUcoresbasedonthe
currentutilization,deliveringbetterperformanceperwattforimprovedsystemenergy
efciency.
Congurationoptions:[Disabled][EnableAuto][EnableManual]
4-12 Chapter 4: BIOS Setup
4.5.1 Trusted Computing
Conguration
Security Device Support [Disabled]
Allows you to enable or disable the BIOS support for security device.
Congurationoptions:[Disabled][Enabled]
4.5.2 ACPI Settings
Enable ACPI Auto Conguration [Disabled]
AllowsyoutoenableordisabletheBIOSACPIAutoConguration.
Congurationoptions:[Disabled][Enabled]
Enable Hibernation [Enabled]
Allows you to enable or disable the ability of the system to hibernate (OS/Sleep State).
Congurationoptions:[Disabled][Enabled]
This option may be not effective with some OS.
4-13
Z11PA-D8 Series
4.5.4 Super IO Conguration
Serial Port 1 Conguration
Allows you to set the parameters of Serial Port 1.
Serial Port [Enabled]
Allows you to enable or disable Serial Port.
Congurationoptions:[Disabled][Enabled]
The following item appears only when you set Serial Port to [Enabled].
Change Settings [Auto]
Allows you to choose the setting for Super IO device.
Congurationoptions:[Auto][IO=3F8h;IRQ=4;]
[IO=3F8h;IRQ=3,4,5,6,7,9,10,11,12;]
[IO=2F8h;IRQ=3,4,5,6,7,9,10,11,12;]
[IO=3E8h;IRQ=3,4,5,6,7,9,10,11,12;]
[IO=2E8h;IRQ=3,4,5,6,7,9,10,11,12;]
4.5.3 Smart Settings
SMART Self Test [Enabled]
Allows you to run SMART Self Test on all HDDs during POST.
Congurationoptions:[Disabled][Enabled]
4-14 Chapter 4: BIOS Setup
4.5.5 Serial Port Console Redirection
Console Redirection Settings
TheseitemsbecomecongurableonlywhenyouenabletheConsole Redirection
item. The settings specify how the host computer and the remote computer (which the
user is using) will exchange data. Both computers should have the same or compatible
settings.
Terminal Type [VT-UTF8]
Allows you to set the terminal type.
[VT100] ASCIIcharset.
[VT100+] ExtendsVT100tosupportcolor,functionkeys,etc.
[VT-UTF8] UsesUTF8encodingtomapUnicodecharsonto1ormorebytes.
[ANSI] ExtendedASCIIcharset.
Bits per second [57600]
Selects serial port transmission speed. The speed must be matched on the other side.
Long or noisy lines may require lower speeds.
Congurationoptions:[9600][19200][38400][57600][115200]
Data Bits [8]
Congurationoptions:[7][8]
The following item appears only when you set Console Redirection to [Enabled].
COM1/COM2
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Congurationoptions:[Disabled][Enabled]
4-15
Z11PA-D8 Series
Parity [None]
Aparitybitcanbesentwiththedatabitstodetectsometransmissionerrors.[Mark]
and[Space]paritydonotallowforerrordetection.
[None] None
[Even] paritybitis0ifthenumof1’sinthedatabitsiseven
[Odd] paritybitis0ifnumof1’sinthedatabitsisodd
[Mark] paritybitisalways1
[Space] paritybitisalways0
Stop Bits [1]
Stopbitsindicatetheendofaserialdatapacket.(Astartbitindicatesthebeginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit.
Congurationoptions:[1][2]
Flow Control [Hardware RTS/CTS]
Flowcontrolcanpreventdatalossfrombufferoverow.Whensendingdata,ifthe
receivingbuffersarefull,a“stop”signalcanbesenttostopthedataow.Oncethe
buffersareempty,a“start”signalcanbesenttore-starttheow.Hardwareowcontrol
uses two wires to send start/stop signals.
Congurationoptions:[None][HardwareRTS/CTS]
VT -UTF8 Combo Key Support [Enabled]
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100
terminals.
Congurationoptions:[Disabled][Enabled]
Recorder Mode [Disabled]
Withthismodeenabledonlytextwillbesent.ThisistocaptureTerminaldata.
Congurationoptions:[Disabled][Enabled]
Legacy OS Redirection Resolution [80x24]
This allows you to set the number of rows and columns supported on the Legacy OS.
Congurationoptions:[80x24][80x25]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty.
Congurationoptions:[VT100][LINUX][XTERMR6][SCO][ESCN][VT400]
Redirection After BIOS POST [Always Enable]
This setting allows you to specify if Bootloader is selected than Legacy console
redirection.
Congurationoptions:[AlwaysEnable][Bootloader]
Legacy Console Redirection Settings
Legacy Console Redirection Port [COM1]
Allows you to select a COM port to display redirection of Legacy OS and Legacy OPROM
Messages.
Congurationoptions:[COM1][COM2]
4-16 Chapter 4: BIOS Setup
Serial Port for Out-of-Band Management/Windows Emergency Management
Services (EMS)
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Congurationoptions:[Disabled][Enabled]
The following item appears only when you set Console Redirection to [Enabled].
Console Redirection Settings
Out-of-Band Mgmt Port [COM1]
MicrosoftWindowsEmergencyManagementServices(EMS)allowforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[COM1][COM2]
Terminal Type [VT-UTF8]
MicrosoftWindowsEmergencyManagementServices(EMS)allowforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[VT100][VT100+][VT-UTF8][ANSI]
Bits per second [115200]
MicrosoftWindowsEmergencyManagementServices(EMS)allowforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[9600][19200][57600][115200]
Flow Control [None]
MicrosoftWindowsEmergencyManagementServices(EMS)allowforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[None][HardwareRTS/CTS][SoftwareXon/Xoff]
4-17
Z11PA-D8 Series
Onboard I350 LAN Conguration
Intel LAN1 Enable [Enabled]
Allows you to enable or disable the Intel LAN.
Congurationoptions:[Disabled][Enabled]
The following items appear only when Intel LAN1 Enable is set to [Enabled].
Intel LAN 1 ROM Type [PXE]
Allows you to select the Intel LAN ROM type.
Congurationoptions:[PXE][iSCSI][Disabled]
Intel LAN2 Enable [Enabled]
Allows you to enable or disable the Intel LAN.
Congurationoptions:[Disabled][Enabled]
The following items appear only when Intel LAN2 Enable is set to [Enabled].
Intel LAN 2 ROM Type [Disabled]
Allows you to select the Intel LAN ROM type.
Congurationoptions:[PXE][iSCSI][Disabled]
4.5.6 Onboard LAN Conguration
4-18 Chapter 4: BIOS Setup
4.5.7 APM
AllowsyoutoconguretheAdvancePowerManagement(APM)settings.
Restore AC Power Loss [Last State]
Whensetto[PowerOff],thesystemgoesintooffstateafteranACpowerloss.Whenset
to[PowerOn],thesystemwillrebootafteranACpowerloss.Whensetto[LastState],the
systemgoesintoeitherofforonstate,whateverthesystemstatewasbeforetheACpower
loss.
Congurationoptions:[PowerOff][PowerOn][LastState]
Power On By PCIE [Disabled]
[Disabled] DisablesthePCIEdevicestogenerateawakeevent.
[Enabled] EnablesthePCIEdevicestogenerateawakeevent.
Power On By RTC [Disabled]
[Disabled] DisablesRTCtogenerateawakeevent.
[Enabled] Whensetto[Enabled],theitemsRTC Alarm Date (Days) and
Hour/Minute/Secondwillbecomeuser-congurablewithsetvalues.
4-19
Z11PA-D8 Series
4.5.8 PCI Subsystem Settings
AllowsyoutocongurePCI,PCI-X,andPCIExpressSettings.
Load RT32 Image [Enabled]
This option allows you to enable or disable RT32 Image Loading.
Congurationoptions:[Disabled][Enabled]
Above 4G Decoding [Disabled]
Allows you to enable or disable 64-bit capable devices to be decoded in above 4G address
space.Itonlyworksifthesystemsupports64-bitPCIdecoding.
Congurationoptions:[Disabled][Enabled]
SR-IOV Support [Enabled]
This option enables or disables SIngle Root IO Virtualization Support if the system has SR-
IOV capable PCIe devices.
Congurationoptions:[Disabled][Enabled]
BME DMA Mitigation [Disabled]
This allows you to enable or disable re-enabling Bus Master Attribute disabled during PCI
enumerationforPCIBridgesafterSMMlocked.
Congurationoptions:[Disabled][Enabled]
PCIE Express Settings
PCI Express Device Register Settings
Relaxed Ordering [Enabled]
Enables or disables PCI Express device relaxed ordering.
Congurationoptions:[Disabled][Enabled]
Extended Tag [Disabled]
IfEnableallowsdeviceisuse8-bittageldasarequester.
Congurationoptions:[Disabled][Enabled]
No Snoop [Enabled]
Enables or disables PCI Express device No snoop option.
Congurationoptions:[Disabled][Enabled]
4-20 Chapter 4: BIOS Setup
PCI Express Link Register Settings
ASPM Support [Disabled]
AllowstosettheASPMlevel.Congurationoptions:[Disabled][Auot][ForceL0s]
[ForceL0s] ForcealllinkstoL0sstate.
[Auto] BIOSautocongure.
[Disabled] DisabledASPM.
Unpopulated Links [Keep Link ON]
Inordertosavepower,softwarewilldisableunpopulatedPCIExpresslinks,ifthis
option set to Disabled.
Congurationoptions:[KeepLinkON][Disabled]
PCIE OPROM Slot Options
PCIE1-3 Slot OPROM [Enabled]
This option allows you to enable or disable the OPROM of the PCIe slots.
Congurationoptions:[Disabled][Enabled]
MEZZ1 Slot OPROM [Enabled]
This option allows you to enable or disable the OPROM of the MEZZ slot.
Congurationoptions:[Disabled][Enabled]
4-21
Z11PA-D8 Series
4.5.9 USB Conguration
Legacy USB Support [Enabled]
Allows you to enable or disable Legacy USB device support.
Congurationoptions:[Enabled][Disabled][Auto]
USB Mass Storage Driver Support [Enabled]
Allows you to enable or disable the USB Mass Storage driver support.
Congurationoptions:[Disabled][Enabled]
Mass Storage Devices
AMI Virtual CDROM0-2 / Floppy / HDisk0 1.00 [Auto]
Allows you to select the mass storage device emulation type.
Congurationoptions:[Auto][Floppy][ForcedFDD][HardDisk][CD-ROM]
4-22 Chapter 4: BIOS Setup
4.5.10 CSM Conguration
CSM Support [Enabled]
This option allows you to enable or disable CSM Support.
Congurationoptions:[Disabled][Enabled]
The following item appears only when CSM Support is set to [Enabled].
GateA20 Active [Upon Request]
This allows you to set the GA20 option.
Congurationoptions:[UponRequest][Always]
Option ROM Messages [Force BIOS]
This allows you to set the display mode for option ROM.
Congurationoptions:[ForceBIOS][KeepCurrent]
INT19 Trap Response [Immediate]
[Immediate] Executethetraprightaway.
[Postponed] Executethetrapduringlegacyboot.
Boot Option filter [Legacy only]
This option allows you to control the Legacy/UEFI ROMs priority.
Congurationoptions:[UEFIandLegacy][Legacyonly][UEFIonly]
Network / Storage / Video [Legacy]
ThisoptionallowsyoutocontroltheexecutionofUEFIandLegacyPXE/Storage/
Video OpROM.
Congurationoptions:[UEFI][Legacy]
Other PCI devices [Legacy]
ThisitemdeterminestheOpROMexecutionpolicyfordevicesotherthanNetwork,
Storage,orVideo.
Congurationoptions:[UEFI][Legacy]
4-23
Z11PA-D8 Series
4.5.11 NVMe Conguration
This page will display the NVMe controller and drive information.
Network stack [Disabled]
Enablesordisablesthenetworkstackfeature.
Congurationoptions:[Disable][Enable]
The following item appears only when Network stack is set to [Enabled].
Ipv4 PXE Support [Disabled]
EnablesordisablestheIpv4PXEBootSupport.Ifdisabled,Ipv4PXEbootoptionwill
not be created.
Congurationoptions:[Disabled][Enabled]
Ipv4 HTTP Support [Disabled]
EnablesordisablestheIpv4HTTPBootSupport.Ifdisabled,Ipv4HTTPbootoption
will not be created.
Congurationoptions:[Disabled][Enabled]
Ipv6 PXE Support [Disabled]
EnablesordisablestheIpv6PXEBootSupport.Ifdisabled,Ipv6PXEbootoptionwill
not be created.
Congurationoptions:[Disabled][Enabled]
Ipv6 HTTP Support [Disabled]
EnablesordisablestheIpv6HTTPBootSupport.Ifdisabled,Ipv6HTTPbootoption
will not be created.
Congurationoptions:[Disabled][Enabled]
PXE boot wait time [0]
WaittimetopressESCkeytoabortthePXEboot.
Media detect time [1]
Waittime(inseconds)todetectmedia.
4.5.12 Network Stack Conguration
4-24 Chapter 4: BIOS Setup
4.5.13 iSCSI Conguration
AllowsyoutoconguretheiSCSiparameters.
4.6 Platform Conguration menu
The IntelRCSetup menu items allow you to change the platform settings.
4-25
Z11PA-D8 Series
4.6.1 PCH Conguration
PCH Devices
DeepSx Power Policies [Disabled]
AllowsyoutoconguretheDeepSxModeconguration.
Congurationoptions:[Disabled][EnabledinS5][EnabledinS4andS5]
GP27 Wake From DeepSx [Disabled]
AllowsyoutoenableordisableGP27WakeFromDeepSx.
Congurationoptions:[Disabled][Enabled]
PCI Express Conguration
PCI-E ASPM Support (Global) [L1 Only]
Allows you to select ASPM support for all downstream devices.
Congurationoptions:[Perindividualport][L1Only]
PCH DMI ASPM [Platform-POR]
AllowsyoutocongurethePCHDMIASPM.
Congurationoptions:[Platform-POR][ASPML1][Disabled]
PCH SATA Conguration
SATA Controller [Enabled]
Allows you to enable or disable the SATA Controller.
Congurationoptions:[Disabled][Enabled]
Configure sSATA as [AHCI]
AllowsyoutoidentifytheSATAportconnectedtoSolidStateDriveorHardDiskDrive.
Congurationoptions:[IDE][AHCI][RAID]
Support Aggressive Link Power Management [Enabled]
AllowsyoutoenableordisabletheSupportAggressiveLinkPower(SALP)
Management.
Congurationoptions:[Disabled][Enabled]
4-26 Chapter 4: BIOS Setup
SATA Port 1-8
Port 1-8
Allows you to enable or disable the SATA port.
Congurationoptions:[Disabled][Enabled]
PCH sSATA Conguration
sSATA Controller [Enabled]
Allows you to enable or disable the sSATA Controller.
Congurationoptions:[Disabled][Enabled]
Configure sSATA as [AHCI]
AllowsyoutoidentifytheSATAportconnectedtoSolidStateDriveorHardDiskDrive.
Congurationoptions:[IDE][AHCI][RAID]
Support Aggressive Link Power Management [Enabled]
AllowsyoutoenableordisabletheSupportAggressiveLinkPower(SALP)
Management.
Congurationoptions:[Disabled][Enabled]
sSATA Port 1-3
Port 1-3
Allows you to enable or disable the SATA port.
Congurationoptions:[Disabled][Enabled]
USB Conguration
USB Precondition [Disabled]
AllowsyoutoenableordisablepreconditionworkonUSBhostcontrollerandrootports
for faster enumeration.
Congurationoptions:[Disabled][Enabled]
XHCI Manual Mode [Disabled]
This option is used by validation.
Congurationoptions:[Disabled][Enabled]
The following items appears only when the XHCI Manual Mode is set to [Enabled].
Trunk Clock Gating (BTCG) [Enabled]
Allows you to enable or disable BTCG.
Congurationoptions:[Disabled][Enabled]
Enable USB 3.0 pins [Disable all pins]
Allows you to enable or disable USB 3.0 pins or on a per pin basis.
Congurationoptions:[SelectPer-Pin][Disableallpins][Enableallpins]
USB Per-Connector Disable [Disabled]
Allows you to enable or disable each of the USB physical connectors. Once a
connectorisdisabled,anyUSBdevicespluggedintotheconnectorwillnotbedetected
by BIOS or OS.
Congurationoptions:[Disabled][Enabled]
4-27
Z11PA-D8 Series
The following items appears only when the USB Per-Connector Disable is set to [Enabled].
USB_1-8 [Enabled]
Congurationoptions:[Disabled][Enabled]
USB3_1-5 [Enabled]
Congurationoptions:[Disabled][Enabled]
Security Conguration
SMM BIOS Write Protect [Enabled]
AllowsyoutoenableordisableSMMBIOSWriteProtect.
Congurationoptions:[Disabled][Enabled]
4.6.2 Miscellaneous Conguration
Active Video [Offboard Device]
Allows you to select the video type.
Congurationoptions:[Auto][OnboardDevice][OffboardDevice]
4.6.3 Server ME Conguration
Displays the Server ME Technology parameters on your system.
4-28 Chapter 4: BIOS Setup
4.6.4 Runtime Error Logging Support
Runtime Error Logging
System Errors [Enabled]
This item allows you to enable or disable System Errors.
Congurationoptions:[Disabled][Enabled]
Whea Settings
Whea Support [Disabled]
ThisitemallowsyoutoenableordisabletheWHEAsupport.
Congurationoptions:[Disabled][Enabled]
4.7 Socket Conguration menu
TheIntelRCSetupmenuitemsallowyoutochangethesocketsettings.
4-29
Z11PA-D8 Series
4.7.1 Processor Conguration
Hyper Threading [ALL] [Enabled]
AllowsyoutoenableordisabletheHyper-ThreadingTechnologyfunction.Whendisabled,
only one thread per activated core is enabled.
Congurationoptions:[Disabled][Enabled]
Enable Intel(R) TXT Support [Disabled]
ForcestheXDfeaturelogtoalwaysreturn0whendisabled.
Congurationoptions:[Disabled][Enabled]
VMX [Enabled]
EnablestheVanderpoolTechnology.Takeseffectafterreboot.
Congurationoptions:[Disabled][Enabled]
Enable SMX [Disabled]
Enables the Safer Mode Extensions.
Congurationoptions:[Disabled][Enabled]
Hardware Prefetcher [Enabled]
This Item allows you to turn on/off the mid level cache(L2) streamer prefetcher.
Congurationoptions:[Disabled][Enabled]
L2 RFO Prefetch Disable [Disabled]
This Item allows you to turn on/off L2 RFO prefetcher.
Congurationoptions:[Disabled][Enabled]
4-30 Chapter 4: BIOS Setup
Adjacent Cache Prefetch [Enabled]
ThisItemallowsyoutoturnon/offprefetchingofadjacentcachelines.
Congurationoptions:[Disabled][Enabled]
DCU Streamer Prefetcher [Enabled]
This Item allows you to enable or disable prefetcher of next L1 data line.
Congurationoptions:[Disabled][Enabled]
DCU IP Prefetcher [Enabled]
This Item allows you to enable or disable prefetch of next L1 line based upon sequential load
history.
Congurationoptions:[Disabled][Enabled]
LLC Prefetch [Disabled]
This Item allows you to enable or disable LLC Prefetch on all threads.
Congurationoptions:[Disabled][Enabled]
DCU Mode [32K 8Way Without ECC]
Congurationoptions:[32K8WayWithoutECC][16K4WayWithECC]
Extended APIC [Disabled]
This Item allows you to enable or disable the extended APIC support.
Congurationoptions:[Disabled][Enabled]
AES-NI [Enabled]
This Item allows you to enable or disable the AES-NI support.
Congurationoptions:[Disabled][Enabled]
4.7.2 Common RefCode Conguration
MMIO High Base [56T]
This item allows you to select the MMIO High Base.
Congurationoptions:[56T][40T][24T][16T][4T][1T]
MMIO High Granularity Size [256G]
This item allows you to select the allocation size used to assign MMIOH resources.
Congurationoptions:[1G][4G][16G][64G][256G][1024G]
Numa [Enabled]
This item enables or disables the Non uniform Memory Access (NUMA).
Congurationoptions:[Disabled][Enabled]
4-31
Z11PA-D8 Series
4.7.3 UPI Conguration
UPI General Conguration
UPI Status
This item displays information about the UPI status.
Link Speed Mode [Fast]
ThisitemallowsyoutoselecttheUPIlinkspeedaseitherthefastmodeorslowmode.
Congurationoptions:[Slow][Fast]
Link Frequency Select [Auto]
ThisitemallowsforselectingtheUPIlinkfrequency.
Congurationoptions:[Auto][9.6GB/s][10.4GB/s][UsePerLinkSetting]
UPI Link0p Enable [Enabled]
Congurationoptions:[Disabled][Enabled][Auto]
UPI Link1 Enable [Enabled]
Congurationoptions:[Disabled][Enabled][Auto]
Directory Mode Enable [Enabled]
Congurationoptions:[Disabled][Enabled]
SNC [Disabled]
Congurationoptions:[Disabled][Enabled][Auto]
KTI Prefetch [Enabled]
Congurationoptions:[Disabled][Enabled]
Local/Remote Threshold [Auto]
Congurationoptions:[Disabled][Auto][Low][Medium][High]
Stale AtoS [Disabled]
Congurationoptions:[Disabled][Enabled][Auto]
LLC dead line alloc [Enabled]
Congurationoptions:[Disabled][Enabled][Auto]
4-32 Chapter 4: BIOS Setup
4.7.4 Memory Conguration
Enforce POR [Auto]
Allows you to enforce POR restrictions for DDR4 frequency and voltage programming.
Congurationoptions:[Auto][POR][Disabled]
Memory Frequency [Auto]
Allows you to select the memory frequency setting.
Congurationoptions:[Auto][1800]-[3000-OvrClk]
Data Scrambling for DDR4 [Auto]
Allows you to enable or disable data scrambling.
Congurationoptions:[Auto][Disabled][Enabled]
Memory Topology
Displays memory topology with DIMM population information.
Page Policy
AllowsyoutocongurePagePolicysettings.
Page Policy [Disabled]
Congurationoptions:[Auto][Closed][Adaptive]
Memory Map
IMC Interleaving [Auto]
Select different IMC interleaving setting.
Congurationoptions:[Auto][1-wayInterleave][2-wayInterleave]
Channel Interleaving [Auto]
Select different channel interleaving setting.
Congurationoptions:[Auto][1-wayInterleave][2-wayInterleave]
[3-wayInterleave]
4-33
Z11PA-D8 Series
Rank Interleaving [Auto]
Selectdifferentrankinterleavingsetting.
Congurationoptions:[Auto][1-wayInterleave][2-wayInterleave]
[4-wayInterleave][8-wayInterleave]
Memory RAS Conguration
Mirror Mode [Disabled]
Allows you to select Mirror Modes. Mirror Mode will set entire 1LM/2LM memory in
systemtobemirrored,consequentlyreducingthememorycapacitybyhalf.Enabling
MirrorModewilldisableXPTPrefetch.
Congurationoptions:[Disabled][MirrorMode1LM][MirrorMode2LM]
UEFI ARM Mirror [Disabled]
Allows you to enable or disable UEFI ARM Mirror.
Congurationoptions:[Disabled][Enabled]
Memory Rank Sparing [Disabled]
AllowsyoutoenableordisableMemoryRankSparing
Congurationoptions:[Disabled][Enabled]
Patrol Scrub [Enabled]
Allows you to enable or disable Patrol Scrub.
Congurationoptions:[Disabled][Enabled]
NGN Conguration
Average Power Budget (in mW) [18000]
Allowsyoutosetthepowermanagementpolicyforaveragepowerin250mW
increments.
Congurationoptions:[10000]-[18000]
4-34 Chapter 4: BIOS Setup
Socket1 Conguration
ThisitemallowsyoutoconguresettingsrelatedtothecorrespondingPCIEport.
Intel(R) VT for Directed I/O (VT-d)
Intel(R) VT for Directed I/O (VT-d) [Disabled]
Allows you to enable or disable the Intel Virtualization Technology for Directed I/O.
Congurationoptions:[Disabled][Enabled]
PCI Express Global Options
PCI-E ASPM Support (Global) [Per-Port]
Allows you to enable or disable ASPM support for all downstream devices.
Congurationoptions:[Disabled][Per-Port][L1Only]
PCIE relaxed Ordering [Enabled]
Allows you to enable or disable PCIE relaxed Ordering.
Congurationoptions:[Disabled][Enabled]
4.7.5 IIO Conguration
4-35
Z11PA-D8 Series
4.7.6 Advanced Power Management Conguration
CPU P State Control
Boot performance mode [Max Performance]
Allows you to switch between Boot performance mode.
Congurationoptions:[MaxPerformance][MaxEfcient][SetbyIntelNodeManager]
Energy Efficient Turbo [Enabled]
AllowsyoutoenableordisableEnergyEfcientTurbo.
Congurationoptions:[Disabled][Enabled]
Turbo Mode [Enabled]
Allows you to enable or disable Turbo Mode.
Congurationoptions:[Disabled][Enabled]
Hardware PM State Control
Hardware P-States [Native Mode]
Allows you to switch between Hardware P-States mode.
Congurationoptions:[Disabled][NativeMode][OutofBandMode][NativeModewith
noLegacySupport]
CPU C State Control
Autonomous Core C-State [Disabled]
Allows you to enable or disable Autonomous Core C-State Report.
Congurationoptions:[Disabled][Enabled]
CPU C6 Report [Auto]
Allows you to select CPU C6 Report.
Congurationoptions:[Disabled][Enabled][Auto]
OS ACPI Cx [ACPI C2]
Allows you to select OS ACPI Cx Report.
Congurationoptions:[ACPIC2][ACPIC3]
Package C State Control
Package C State [Auto]
AllowsyoutoselectPackageCState.
Congurationoptions:[C0/C1state][C2state][C6(nonRetentionstate][C6(Retention
state][NoLimit][Auto]
4-36 Chapter 4: BIOS Setup
CPU Thermal Control
CPU T-State Control
Software Controlled T-States [Disabled]
Allows you to enable or disable Software Controlled T-States.
Congurationoptions:[Disabled][Enabled]
CPU - Advanced PM Tuning
Energy Perf BIAS
Power Performance Tuning [OS Controls EPB]
Congurationoptions:[OSControlsEPB][BIOSControlsEPB]
The following item appears only when you set Power Performance Tuning to
[OS Controls EPB].
PECI PCS EPB [OS Controls EPB]
This option controls whether PECI has control over EPB.
Congurationoptions:[OSControlsEPB][PECIControlsEPBusingPCS]
The following item appears only when you set Power Performance Tuning to
[BIOS Controls EPB].
ENERGY_PERF_BIAS_CFG Mode [Balanced Performance]
Congurationoptions:[Performance][BalancedPerformance][BalancedPower]
[Power]
Dynamic Loadline Switch [Enabled]
Congurationoptions:[Disabled][Enabled]
Workload Configuration [UMA]
Thisoptionallowsoptimizationfortheworkloadcharacterization.
Congurationoptions:[UMA][NUMA]
Averaging Time Window [17]
This option is used to control the effective window of the average C0 an P0 time.
Congurationoptions:[0]-[FF]
P0 TotalTimeThreshold Low [23]
TheHWswitchingmechanismDISABLEStheperformancesetting(0)whenthetotal
P0 time is less than the threshold set.
Congurationoptions:[0]-[3F]
P0 TotalTimeThreshold High [3a]
TheHWswitchingmechanismEnablestheperformancesetting(0)whenthetotalP0
time is greater than the threshold set.
Congurationoptions:[0]-[3F]
4-37
Z11PA-D8 Series
4.8 Event Logs menu
The Event Logs menu items allow you to change the event log settings and view the system
event logs.
4.8.1 Change Smbios Event Log Settings
Press<Enter>tochangetheSmbiosEventLogconguration.
Enabling/Disabling Options
Smbios Event Log [Enabled]
Change this to enable or disable all features of Smbios Event Logging during boot.
Congurationoptions:[Disabled][Enabled]
Erasing Settings
Erase Event Log [No]
Choose options for erasing Smbios Event Log. Erasing is done prior to any logging activation
during reset.
Congurationoptions:[No][Yes,Nextreset][Yes,Everyreset]
4.8.2 View Smbios Event Log
Press <Enter> to view all smbios event logs.
Allvalueschangedheredonottakeeffectuntilcomputerisrestarted.
4-38 Chapter 4: BIOS Setup
4.9 Server Mgmt menu
The Server Management menu displays the server management status and allows you to
change the settings.
OS Watchdog Timer [Disabled]
This item allows you to start a BIOS timer which can only be shut off by Intel Management
Software after the OS loads.
Congurationoptions:[Disabled][Enabled]
ThefollowingitemsiscongurableonlywhentheOS Watchdog Timer is set to [Enabled].
OS Wtd Timer Timeout [10 minutes]
AllowsyoutocongurethelengthfotheOSBootWatchdogTimer.
Congurationoptions:[5minutes][10minutes][15minutes][20minutes]
OS Wtd Timer Policy [Reset]
ThisitemallowsyoutocongurethehowthesystemshouldrespondiftheOSBoot
WatchTimerexpires.
Congurationoptions:[DoNothing][Reset][PowerDown]
System Event Log
AllowsyoutochangetheSELeventlogconguration.
Erase SEL [No]
Allows you to choose options for erasing SEL.
Congurationoptions:[No][Yes,Onnextreset][Yes,Oneveryreset]
When SEL is Full [Do Nothing]
Allows you to choose options for reactions to a full SEL.
Congurationoptions:[DoNothing][EraseImmediately]
BMC network conguration
Thesub-itemsinthiscongurationallowyoutoconguretheBMCnetworkparameters.
View System Event Log
This item allows you to view the system event log records.
4-39
Z11PA-D8 Series
4.10 Security menu
This menu allows a new password to be created or a current password to be changed. The
menualsoenablesordisablestheSecureBootstateandletstheuserconguretheSystem
Mode state.
Administrator Password
To set an administrator password:
1. Select the Administrator Password item and press <Enter>.
2. FromtheCreateNewPasswordbox,keyinapassword,thenpress<Enter>.
3. Conrmthepasswordwhenprompted.
To change an administrator password:
1. Select the Administrator Password item and press <Enter>.
2. FromtheEnterCurrentPasswordbox,keyinthecurrentpassword,thenpress
<Enter>.
3. FromtheCreateNewPasswordbox,keyinanewpassword,thenpress<Enter>.
4. Conrmthepasswordwhenprompted.
Tocleartheadministratorpassword,followthesamestepsasinchanginganadministrator
password,butpress<Enter>whenpromptedtocreate/conrmthepassword.
4-40 Chapter 4: BIOS Setup
User Password
To set a user password:
1. Select the User Password item and press <Enter>.
2. FromtheCreateNewPasswordbox,keyinapassword,thenpress<Enter>.
3. Conrmthepasswordwhenprompted.
To change a user password:
1. Select the User Password item and press <Enter>.
2. FromtheEnterCurrentPasswordbox,keyinthecurrentpassword,thenpress
<Enter>.
3. FromtheCreateNewPasswordbox,keyinanewpassword,thenpress<Enter>.
4. Conrmthepasswordwhenprompted.
To clear a user password:
1. Select the Clear User Password item and press <Enter>.
2. Select YesfromtheWarningmessagewindowthenpress<Enter>.
Secure Boot
This item allows you to customize the Secure Boot settings.
Secure Boot
Allows you to enable or disable Secure Boot.
Congurationoptions:[Disabled][Enabled]
4-41
Z11PA-D8 Series
Bootup NumLock State [On]
Allowsyoutoselectthepower-onstatefortheNumLock.
Congurationoptions:[Off][On]
Boot Logo Display [Auto]
Allows you to enable or disable the full screen logo display feature.
Congurationoptions:[Auto][FullScreen][Disabled]
POST Report [5 sec]
Allows you to set the desired POST Report waiting time from 1 to 10 seconds.
Congurationoptions:[1sec]~[10sec][UntilPressESC]
Boot Option Priorities
These items specify the boot device priority sequence from the available devices. The
number of device items that appears on the screen depends on the number of devices
installed in the system.
• Toselectthebootdeviceduringsystemstartup,press<F8>whenASUSLogo
appears.
• ToaccessWindowsOSinSafeMode,pleasepress<F8>afterPOST.
Hard Drive / CD/DVD ROM Drive / Network Device BBS Priorities
These items appear allow you to set the order of the legacy devices in this group.
4.11 Boot menu
The Boot menu items allow you to change the system boot options.
4-42 Chapter 4: BIOS Setup
4.12 Tool menu
TheToolmenuitemsallowyoutocongureoptionsforspecialfunctions.Selectanitemthen
press <Enter> to display the submenu.
IPMI Hardware Monitor
Allows you to run the IPMI hardware monitor.
Start EZ Flash
Allows you to run ASUS EZ Flash BIOS ROM Utility when you press <Enter>. Refer to the
ASUS EZ Flash Utility section for details.
Pressing <Esc> does not immediately exit this menu. Select one of the options from this
menu or <F10> from the legend bar to exit.
Discard Changes & Exit
Exit System setup without saving any changes.
Save Changes & Reset
Exit System setup after saving the changes.
Restore Defaults
Restore/load default values for all the setup options.
Boot Override
These items displays the available devices. The device items that appears on the screen
dependsonthenumberofdevicesinstalledinthesystem.Clickanitemtostartbootingfrom
the selected device.
4.13 Save & Exit menu
The Save & Exit menu items allow you to save or discard your changes to the BIOS items.
5
RAID Conguration
This chapter provides instructions for setting up, creating,
and conguring RAID sets using the available utilities.
Chapter 5: RAID Conguration
5-2 Chapter 5: RAID Conguration
5.1 Setting up RAID
The motherboard supports the Intel® Rapid Storage Technology enterprise Option ROM
Utility with RAID 0, RAID 1, RAID 10, and RAID 5 support.
5.1.1 RAIDdenitions
RAID 0
(Data striping)
optimizes two identical hard disk drives to read and write data in
parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a
sustained data transfer rate, double that of a single disk alone, thus improving data access
and storage. Use of two new identical hard disk drives is required for this setup.
RAID 1
(Data mirroring)
copies and maintains an identical image of data from one drive to a
second drive. If one drive fails, the disk array management software directs all applications
to the surviving drive as it contains a complete copy of the data in the other drive. This RAID
conguration provides data protection and increases fault tolerance to the entire system. Use
two new drives or use an existing drive and a new drive for this setup. The new drive must be
of the same size or larger than the existing drive.
RAID 10 is data striping and data mirroring combined without parity (redundancy data) having
to be calculated and written. With the RAID 10 conguration you get all the benets of both
RAID 0 and RAID 1 congurations. Use four new hard disk drives or use an existing drive and
three new drives for this setup.
RAID 5 stripes both data and parity information across three or more hard disk drives. Among
the advantages of RAID 5 conguration include better HDD performance, fault tolerance, and
higher storage capacity. The RAID 5 conguration is best suited for transaction processing,
relational database applications, enterprise resource planning, and other business systems.
Use a minimum of three identical hard disk drives for this setup.
If you want to boot the system from a hard disk drive included in a created RAID set, copy
rst the RAID driver from the support DVD to a oppy disk before you install an operating
system to the selected hard disk drive.
5-3
Z11PA-D8 Series
5.1.3 Setting the RAID item in BIOS
You must set the RAID item in the BIOS Setup before you can create a RAID set from SATA
hard disk drives attached to the SATA connectors supported by Intel® C621 chipset.
To do this:
1. Enter the BIOS Setup during POST.
2. Go to the Advanced Menu > PCHSATAConguration, then press <Enter>.
3. Set SATA Mode to [RAID Mode].
4. Press <F10> to save your changes and exit the BIOS Setup.
Refer to Chapter 4 for details on entering and navigating through the BIOS Setup.
5.1.4 RAIDcongurationutilities
Depending on the RAID connectors that you use, you can create a RAID set using the utilities
embedded in each RAID controller. For example, use the Intel® Rapid Storage Technology
if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the
Intel® C621 chipset.
Refer to the succeeding section for details on how to use the RAID conguration utility.
5.1.2 Installing hard disk drives
The motherboard supports Serial ATA for RAID set conguration. For optimal performance,
install identical drives of the same model and capacity when creating a disk array.
To install the SATA hard disks for RAID conguration:
1. Install the SATA hard disks into the drive bays following the instructions in the system
user guide.
2. Connect a SATA signal cable to the signal connector at the back of each drive and to
the SATA connector on the motherboard.
3. Connect a SATA power cable to the power connector on each drive.
5-4 Chapter 5: RAID Conguration
5.2 Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM Utility
The Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM utility allows you
to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set from Serial ATA hard disk
drives that are connected to the Serial ATA connectors supported by the Southbridge.
The navigation keys at the bottom of the screen allow you to move through the menus
and select the menu options.
The RAID BIOS setup screens shown in this section are for reference only and may not
exactly match the items on your screen.
To launch the Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM utility:
1. Turn on the system.
2. During POST, press <Ctrl>+<I> to display the utility main menu.
Before you proceed, ensure that you have installed the Serial ATA hard disk drives, and
have set the correct SATA mode in the BIOS setup. You can refer to the Installing Serial
ATA hard disks, and Setting the RAID item in BIOS sections in this manual for more
information.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes:
None defined.
Physical Disks:
ID Drive Model Serial # Size Type/Status(Vol ID)
0 ST3300656SS HWAS0000991753TR 279.3GB Non-RAID Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Non-RAID Disk
2 ST3300656SS 397600009846UEDY 279.3GB Non-RAID Disk
3 ST3300656SS GWC50000991756G6 279.3GB Non-RAID Disk
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
5-5
Z11PA-D8 Series
5.2.1 Creating a RAID set
To create a RAID set:
1. From the utility main menu, select 1. Create RAID Volume and press <Enter>.
2. Key in a name for the RAID set and press <Enter>.
3. Press the up/down arrow keys to select a RAID Level that you wish to create then
press <Enter>.
4. From the Disks item eld, press <Enter> to select the hard disk drives that you want to
include in the RAID set.
5. Use the up/down arrow keys to move the selection bar then press <Space> to select a
disk. A small triangle before the Port number marks the selected drive. Press <Enter>
when you are done.
[ESC]-Previous Menu [ENTER]-Select[ ]Change
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
[ HELP ]
Name:
RAID Level:
Disks:
Strip Size:
Capacity:
Syne:
Create Volume
Enter a unique volume name that has no special characters and is
16 characters or less.
Volume0
RAID0(Strips)
Select Disks
128KB
0.0 GB
N/A
[TAB]-Next
[ SELECT DISKS ]
Port Drive Model Serial # Size Status
0 ST3300656SS HWAS0000991753TR 279.3GB Non-RAID Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Non-RAID Disk
2 ST3300656SS 397600009846UEDY 279.3GB Non-RAID Disk
3 ST3300656SS GWC50000991756G6 279.3GB Non-RAID Disk
Select 1 Master and 1 Recovery disk to create volume.
[ ]-Prev/Next [TAB]-(M)aster [SPACE]-(R)ecovery [ENTER]-Done
5-6 Chapter 5: RAID Conguration
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0,
10 and 5 only) then press <Enter>. The available stripe size values range from 4 KB to
128 KB. The following are typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
We recommend a lower stripe size for server systems, and a higher stripe size for
multimedia computer systems used mainly for audio and video editing.
7. In the Capacity eld item, key in the RAID volume capacity that you want to use and
press <Enter>. The default value eld indicates the maximum allowed capacity.
8. Press <Enter> to start creating the RAID volume.
9. From the following warning message, press <Y> to create the RAID volume and return
to the main menu, or press <N> to go back to the CREATE VOLUME menu.
WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
Are you sure you want to create this volume? (Y/N):
5-7
Z11PA-D8 Series
5.2.2 Deleting a RAID set
Take caution when deleting a RAID set. You will lose all data on the hard disk drives when
you delete a RAID set.
To delete a RAID set:
1. From the utility main menu, select 2. Delete RAID Volume and press <Enter>.
2. From the Delete Volume Menu, press the up/down arrow keys to select the RAID set
you want to delete then press <Del>.
3. Press <Y> to conrm deletion of the selected RAID set and return to the utility main
menu, or press <N> to return to the DELETE VOLUME menu.
[ESC]-Previous Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ DELETE VOLUME MENU ]
[ HELP ]
Deleting a volume will reset the disks to non-RAID
WARNING: ALL DISK DATA WILL BE DELETED.
(This does not apply to Recovery volumes)
[DEL]-Delete Volume
Name Level Drives Capacity Status Bootable
Volume0 RAID0(Stripe) 2 298.0GB Normal Yes
ALL DATA IN THE VOLUME WILL BE LOST!
(This does not apply to Recovery volumes)
Are you sure you want to delete volume “Volume0”? (Y/N):
[ DELETE VOLUME VERIFICATION ]
5-8 Chapter 5: RAID Conguration
5.2.3 Resetting disks to Non-RAID
Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a
RAID volume hard disk drive deletes all internal RAID structure on the drive.
To reset a RAID set:
1. From the utility main menu, select 3. Reset Disks to Non-RAID and press <Enter>.
2. Press the up/down arrow keys to select the drive(s) or disks of the RAID set you want
to reset, then press <Space>. A small triangle before the Port number marks the
selected drive. Press <Enter> when you are done.
3. Press <Y> in the conrmation window to reset the drive(s) or press <N> to return to the
utility main menu.
Port Drive Model Serial # Size Status
0 ST3300656SS HWAS0000991753TR 279.3GB Member Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Member Disk
Select the disks that should be reset.
Resetting RAID disk will remove its RAID structures
and revert it to a non-RAID disk.
[ ]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
[ RESET RAID DATA ]
WARNING: Resetting a disk causes all data on the disk to be lost.
(This does not apply to Recovery volumes)
5-9
Z11PA-D8 Series
Select a destination disk with the same size as the original hard disk.
5.2.5 Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays
the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array
with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. During POST, press <Ctrl>+<I> at the prompt to enter the Intel Rapid Storage
Technology option ROM utility.
2. If there is a non-RAID SATA Hard Disk available, the utility will prompt you to rebuild
the RAID. Press the up/down arrow keys to select the destination disk then Press
<Enter> to start the rebuilding process, or press <ESC> to exit.
5.2.4 Exiting the Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM utility
To exit the utility:
1. From the utility main menu, select 4. Exit then press <Enter>.
2. Press <Y> to exit or press <N> to return to the utility main menu.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XXX.GB
“Degraded” volume and disk available for rebuilding detected. Selectign
a disk initiates a rebuild. Rebuild completes in the operating system.
[ ]-Previous/Next [ENTER]-Select [ESC]-Exit
[ DEGRADED VOLUME DETECTED ]
Are you sure you want to exit? (Y/N):
[ CONFIRM EXIT ]
5-10 Chapter 5: RAID Conguration
3. The utility immediately starts rebuilding after the disk is selected. When done, the
status of the degraded RAID volume is changed to “Rebuild”.
4. Press <Esc> to exit Intel Rapid Storage Technology and reboot the system.
5. Select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or
click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Storage
Manager utility.
6. From the View menu, select Advanced Mode to display the details of the Intel Rapid
Storage Console.
7. From the Volumes view option, select RAID volume to view the rebuilding status.
When nished, the status is changed to “Normal”.
Rebuilding the RAID with a new hard disk
If any of the SATA hard disk drives included in the RAID array failed, the system displays the
status of the RAID volume as “Degraded” during POST. You may replace the disk drive and
rebuild the RAID array.
To rebuild the RAID with a new hard disk:
1. Remove the failed SATA hard disk and install a new SATA hard disk of the same
specication into the same SATA Port.
Select a destination disk with the same size as the original hard disk.
2. Reboot the system then follow the steps in section Rebuilding the RAID with other
non-RAID disk.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes: *=Data is Encrypted
ID Name Level1 Strip Size Status Bootable
1 Volume0 RAID1(Mirror) N/A 149.0GB Rebuild Yes
Physical Devices:
Port Drive Model Serial # Size Type/Status(Vol ID)
1 ST3160812AS 9LS0F4HL 149.0GB Member Disk(0)
2 ST3160812AS 3LS0JYL8 149.0GB Member Disk(0)
Volumes with “Rebuild” status will be rebuilt within the operating system.
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
5-11
Z11PA-D8 Series
5.2.6 Setting the Boot array in the BIOS Setup Utility
You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-
RAID using the Intel® Rapid Storage Technology enterprise SATA Option ROM utililty.
To set the boot array in the BIOS:
Set at least one of the arrays bootable to boot from the hard disk.
1. Reboot the system and press <Del> to enter the BIOS setup utility during POST.
2. Go to the Boot menu and select the boot option priority.
3. Use up/down arrow keys to select the boot priority and press <Enter>. See the Boot
menu section of Chapter 4 for more details.
4. From the Exit menu, select Save Changes & Exit, then press <Enter>.
5. When the conrmation window appears, select Yes, then press <Enter>.
5-12 Chapter 5: RAID Conguration
5.3 Intel® Rapid Storage Technology enterprise
(Windows)
The Intel® Rapid Storage Technology enterprise allows you to create RAID 0, RAID 1, RAID
10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the
Serial ATA connectors supported by the Southbridge.
You can click Rescan to re-scan any attached hard disks.
1. Turn on the system and go to the windows desktop.
2. Click the Intel® Rapid Storage Technology enterprise icon to display the main menu.
Your storage system is congured for data protection, increased performance and
optimal data storage capacity. You can create additional volumes to further optimize
your storage system.
To enter the Intel® Rapid Storage Technology enterprise utility under Windows operating
system:
You need to manually install the Intel® Rapid Storage Technology enterprise utility on a
Windows® operating system. Please refer to the installation instructions in Chapter 6.
5-13
Z11PA-D8 Series
5.3.1 Creating a RAID set
To create a RAID set:
1. From the utility main menu, select Create Volume and select volume type.
2. Click Next.
3. Enter a name for the RAID set, then select the array disks.
4. Select Volume Size tab, you can drag the bar to decide the volume size.
5. Click Next.
• If you do not want to keep the data on one of the selected disks, select NO when
prompted.
• If you want to Enable volume write-back cache or Initialize volume, click
Advanced.
5-14 Chapter 5: RAID Conguration
6. Conrm the volume creation, than click Create Volume to continue.
This process could take a while depending on the number and size of the disks. You can
continue using other applications during this time.
7. Wait until the process is completed, then click OK when prompted.
You still need to partition your new volume using Windows Disk Management before
adding any data.
The RAID set is displayed in the Volumes list and you can change the settings in
Volume Properties.
5-15
Z11PA-D8 Series
5.3.2 Changing a Volume Type
To change the volume type in Volume Properties:
1. Click the SATA array items you want to change in Volumes eld.
2. From the Volume Properties eld, select Type:RAID 1 Change type.
We recommend a lower stripe size for server systems, and a higher stripe size for
multimedia computer systems used mainly for audio and video editing.
3. You can change the Name, Select the new volume type, and Select additional
disks to include in the new volume if needed.
4. Select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only), and click
OK. The available stripe size values range from 4 KB to 128 KB. The following are
typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
5-16 Chapter 5: RAID Conguration
5.3.3 Deleting a volume
Be cautious when deleting a volume. You will lose all data on the hard disk drives.Before
you proceed, ensure that you back up all your important data from your hard drives.
To delete a volume:
1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes eld
you want to delete.
3. Click Yes to delete the volume and return to the utility main menu, or click No to return
to the main menu.
2. Select Delete volume in Volume Properties eld. The following screen appears.
5-17
Z11PA-D8 Series
5.3.4 Preferences
System Preferences
Allow you to set to show the notication area icon and show system information, warning, or
errors here.
E-Mail Preferences
Allow you to set to sent e-mail of the following events:
• Storage system information
• Storage system warnings
• Storage system errors
5-18 Chapter 5: RAID Conguration
5.4 Intel® Virtual Raid on CPU in BIOS
This feature requires a KEY module to enable CPU RAID functions with Intel® CPU RSTe.
• The KEY module is purchased separately.
• Refer to section 2.8.2 Internal connectors for the location of the VROC_HW_KEY
connector.
Due to hardware design, your motherboard does not support CPU RAID congurations as
OS drives.
To enter the Intel® Virtual Raid on CPU in BIOS:
1. Enter the BIOS Setup during POST.
2. Go to the Advanced menu > Intel(R) Virtual Raid on CPU > All Intel VMD
Controllers then press <Enter> to display the Intel® Virtual Raid on CPU menu.
Refer to Chapter 4 for details on entering and navigating through the BIOS Setup.
Due to chipset limitation, when SATA ports are set to RAID mode, all SATA ports run at
RAID mode together.
5-19
Z11PA-D8 Series
5.4.1 Creating a RAID set
To create a RAID set:
1. From the Intel® Virtual Raid on CPU menu, select Create RAID Volume and press
<Enter>. The following screen appears:
2. When the Name item is selected, enter a name for the RAID set and press <Enter>.
3. When the RAID Level item is selected, press <Enter> to select the RAID level to
create, and then press <Enter>.
4. When the Enable RAID spanned over VMD Controllers item is selected, press
<Enter> and select X to enable this function.
5. Under Select Disks, press <Enter> and select X for the disks you want to include in the
RAID set.
6. When the Strip Size item is selected, press <Enter> to select strip size for the RAID
array (for RAID 0, 10 and 5 only), and then press <Enter>. The available strip size
values range from 4 KB to 128 KB. The following are typical values:
- RAID 0: 128 KB
- RAID 10: 64 KB
- RAID 5: 64 KB
We recommend a lower strip size for server systems, and a higher strip size for multimedia
computer systems used mainly for audio and video editing.
5-20 Chapter 5: RAID Conguration
7. When the Capacity (MB) item is selected, enter the RAID volume capacity that you
want and press <Enter>. The default value indicates the maximum allowed capacity.
8. When the Create Volume item is selected, press <Enter> to create the RAID volume
and return to the Intel® Rapid Storage Technology menu.
5-21
Z11PA-D8 Series
2. When the Delete item is selected, press <Enter>, then select Yes to delete the RAID
volume and return to the Intel® Virtual Raid on CPU menu, or select No to cancel.
5.4.2 Deleting a RAID set
Be cautious when deleting a RAID set. You will lose all data on the hard disk drives when
you delete a RAID set.
To delete a RAID set:
1. From the Intel® Virtual Raid on CPU menu, select the RAID volume you want to delete
and press <Enter>. The following screen appears:
5-22 Chapter 5: RAID Conguration
5.4.3 Installing the RAID controller driver during Windows®
10 OS installation
This part provides the instructions on how to install the RAID controller drivers during OS
installation.
To install the RAID controller driver when installing Windows® 10 OS:
1. Boot the computer using the Windows® 10 OS installation disc. Follow the screen
instructions to start installing Windows® 10.
2. When prompted to choose a type of installation, click Custom: Install Windows only
(advanced).
3. Click Load Driver.
5-23
Z11PA-D8 Series
4. A message appears, reminding you to insert the installation media containing the driver
of the RAID controller driver. If you have only one optical drive installed in your system,
eject the Windows OS installation disc and replace with the motherboard Support DVD
into the optical drive. Click Browse to continue.
5. Locate the driver in the corresponding folder of the support DVD then click OK to
continue.
6. Select the RAID controller driver you need from the list and click Next.
7. When the system nishes loading the RAID driver, replace the motherboard Support
DVD with the Windows Server installation disc. Select the drive to install Windows and
click Next.
8. Setup then proceeds with the OS installation. Follow screen instructions to continue.
5-24 Chapter 5: RAID Conguration
6
Intel® Optane™ DC
Persistent Memory
Conguration
This chapter provides instructions for conguring Intel®
Optane™ DC persistent memory as memory modules (Memory
Mode) or storage devices (App Direct mode).
Chapter 6: Intel® Optane™ DC Persistent Memory Conguration
Chapter 6: Intel® Optane™ DC Persistent Memory Conguration6-2
6.1 Working with Intel® Optane™ DC persistent
memory
The motherboard supports Intel® Optane™ DC persistent memory that can be congured to
operate as memory modules (Memory Mode) or storage devices (App Direct mode).
6.1.1 DCPMM operating systems (OS) and virtual machine
monitor (VMM)
Software Product General Availability and full DCPMM Feature Support
Windows Windows Server 2019
Windows Windows 10 Pro for Workstations
VMWare VMWare ESXi - TTM with CLX/DCPMM
Red Hat Future RHEL 7 update
SUSE SLE15
SLE-12-SP4
Canonical Ubuntu 18.04 LTS
Ubuntu 18.10
KVM Linux KVM
6.1.2 Setting up Intel® Optane™ DC persistent memory as
memory modules
To set up the Intel® Optane™ DC persistent memory as memory modules:
1. Install the memory modules into the DIMM sockets.
Refer to the System memory section for more information on the Intel® Optane™ DC
persistent memory population table.
2. Enter the BIOS Setup during POST.
3. Go to Advanced > Intel(R) Optane(TM) DC Persistent Memory Conguration >
Regions > Create goal cong.
4. Under Memory Mode [%], set the value to 100.
5. Select Create goal cong, then press <Enter>.
6. Press <F10> to save your changes and exit the BIOS Setup to complete.
To check your total memory size, go to Advanced > Intel(R) Optane(TM) DC Persistent
Memory Conguration > Total capacity.
6-3Z11PA-D8 Series
6.1.3 Setting up Intel® Optane™ DC persistent memory as
storage devices (Windows)
To set up the Intel® Optane™ DC persistent memory as storage devices:
1. Install the memory modules into the DIMM sockets.
Refer to the System memory section for more information on the Intel® Optane™ DC
persistent memory population table.
2. Enter the BIOS Setup during POST.
3. Go to Advanced > Intel(R) Optane(TM) DC Persistent Memory Conguration >
Regions > Create goal cong.
4. Under Memory Mode [%], set the value to 0.
5. Select Create goal cong, then press <Enter>.
6. Press <F10> to save your changes and exit the BIOS Setup.
To check your total memory size, go to Advanced > Intel(R) Optane(TM) DC Persistent
Memory Conguration > Total capacity.
7. Boot your system into the Windows OS.
To check whether the system has correctly detected your Intel® Optane™ DC persistent
memory, go to Device Manager > Memory Devices.
8. Launch Windows PowerShell(Admin).
9. Type the following to check which region corresponds to which CPU socket:
Get-PmemUnusedRegion
Ensure to keep track which region corresponds to which CPU socket.
10. Type the following to create a Pmem disk on a designated region:
Get-PmemUnusedRegion [region number] | New-PmemDisk
Example: Get-PmemUnusedRegion 1 | New-PmemDisk
11. Type the following to check the available Pmem disks:
Get-PmemDisk
12. Type the following to initialize the disk:
Initialize-Disk -Number [disk number]
Example: Initialize-Disk -Number 1
Chapter 6: Intel® Optane™ DC Persistent Memory Conguration6-4
13. Type the following to assign a drive letter to the disk:
New-Partition -DiskNumber [disk number] -UseMaximumSize -DriveLetter [drive letter]
Example: New-Partition -DiskNumber 1 -UseMaximumSize -DriveLetter D
14. Type the following to format the disk as dax to complete:
format /q /y /dax [drive letter]:
Example: format /q /y /dax D:
6.1.4 Removing Intel® Optane™ DC persistent memory as
storage devices (Windows)
1. Boot your system into the Windows OS.
2. Launch Windows PowerShell(Admin).
3. Type the following to check the available Pmem disks:
Get-PmemDisk
4. Type the following to clear the data on the Pmem disk:
Clear-Disk –Number [disk number] –RemoveData
Example: Clear-Disk –Number 1 –RemoveData
5. Type the following to remove the Pmem disk to complete:
Get-PmemDisk 1 | Remove-PmemDisk
Example: Get-PmemDisk [disk number] | Remove-PmemDisk
6.1.5 Setting up Intel® Optane™ DC persistent memory on
other operating systems
For more information on setting up Intel® Optane™ DC persistent memory, please refer to:
https://software.intel.com/en-us/persistent-memory
7
Driver Installation
This chapter provides the instructions for installing the
necessary drivers for different system components in both
Linux® and Windows® Operating Systems.
7-2 Chapter 7: Driver Installation
7.1 RAID driver installation
After creating the RAID sets for your server system, you are now ready to install an
operating system to the independent hard disk drive or bootable array. This part provides the
instructions on how to install the RAID controller drivers during OS installation.
7.1.1 CreatingaUSBashdrivewithRAIDdrive
When installing Windows® Server OS, you can load the RAID driver from a USB ash drive.
You can create a USB ash drive with RAID driver in Windows by copying the les from the
support DVD to the USB ash drive.
To copy the RAID driver to a USB ash drive in Windows environment:
1. Place the motherboard support DVD in the optical drive.
2. Connect a USB ash drive to your system.
3. Click on the optical drive to browse the contents of the support DVD.
4. Click Drivers > C620 INTEL RAID > Windows > Driver and then copy the RAID driver
folder to the USB ash drive.
7.1.2 InstallingtheRAIDcontrollerdriver
DuringWindows® Server 2012 R2 OS installation
To install the RAID controller driver when installing Windows® Server 2012 R2 OS:
1. Boot the computer using the Windows® Server 2012 R2 OS installation disc. Follow the
screen instructions to start installing Windows Server 2012 R2.
2. When prompted to choose a type of installation, click Custom:InstallWindowsonly
(advanced).
Z11PA-D8 Series 7-3
3. Click Load Driver.
4. A message appears reminding you to insert the installation media containing the driver of
the RAID controller driver (the installation media can be a CD, DVD, or USB ash drive).
• If you have only one optical drive installed in your system, eject the Windows OS
installation disc and replace with the motherboard Support DVD into the optical
drive.
• Or you may connect a USB ash drive containing the RAID controller driver.
Click Browse to continue.
5. Locate the driver in the corresponding folder of the Support DVD or USB ash drive
and then click OK to continue.
6. Select the RAID controller driver you need from the list and click Next.
7-4 Chapter 7: Driver Installation
7. When the system nishes loading the RAID driver,
• Replace the motherboard Support DVD with the Windows Server installation disc.
• Remove the USB ash drive.
Select the drive to install Windows and click Next.
8. Setup then proceeds with the OS installation. Follow screen instructions to continue.
Z11PA-D8 Series 7-5
7.2 Managementapplicationsandutilitiesinstallation
When you place the support DVD into the optical drive, the DVD automatically displays the
main screen if Autorun is enabled in your computer. By default, the Drivers tab is displayed.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
7.3 RunningtheSupportDVD
• The contents of the support DVD are subject to change at any time without notice.
Visit the ASUS website (www.asus.com) for the latest updates on software and
utilities.
• The support DVD is supported on Windows® Server 2012 R2 and Windows® Server
2016.
The support DVD that is bundled with your motherboard contains drivers, management
applications, and utilities that you can install to maximize the features of your motherboard.
The main screen of the Support DVD contains the following tabs:
1. Drivers
2. Utilities
3. Manual
4. Contact
• The main screen of the Support DVD looks exactly the same on the Windows® Server
2012 R2 and on the Windows® Server 2016 Operating System (OS).
• Onscreen display and content vary depending on the motherboard and chipset. The
screenshots are provided for reference only.
7-6 Chapter 7: Driver Installation
The Drivers Menu shows the available device drivers if the system detects installed devices.
Install the necessary drivers to activate the devices.
7.3.2 Utilities menu tab
The Utilities menu displays the software applications and utilities that the motherboard supports.
7.3.1 Drivers menu tab
Z11PA-D8 Series 7-7
7.3.3 Manual menu
The Manual menu provides a list of supplementary user guides.
You need an internet browser installed in your OS to view the User Guide.
7.3.4 Contactinformationmenu
The Contact menu displays the ASUS contact information, e-mail addresses, and useful links
if you need more information or technical support for your motherboard.
7-8 Chapter 7: Driver Installation
7.4 Intel®chipsetdevicesoftwareinstallation
This section provides the instructions on how to install the Intel® chipset device software on
the system.
You need to manually install the Intel® chipset device software on a Windows operating
system.
To install the Intel® chipset device software:
1. Restart the computer, and then log on with Administrator privileges.
2. Insert the motherboard/system support DVD into the optical drive. The support DVD
automatically displays the Drivers menu if Autorun is enabled in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
3. Click the item Intel®ChipsetDeviceSoftware from the menu.
4. The Intel®ChipsetDeviceSoftware window appears. Click Next to start the
installation.
Z11PA-D8 Series 7-9
5. Read the LicenseAgreement and click Accept to continue the process.
6. Read the ReadmeFileInformation and click Install to start the installation process.
7. Click RestartNow to complete the setup process.
7-10 Chapter 7: Driver Installation
5. Click InstallDriversandSoftware option to begin installation.
7.5 InstallingtheIntel® I210 Gigabit Adapters driver
This section provides the instructions on how to install the Intel® I210 Gigabits Adapter
Driver on the system.
To install the Intel® I210 Gigabit Adapters Driver on the Windows® operating system:
1. Restart the computer.
2. Log on with Administrator privileges.
3. Insert the motherboard/system support DVD to the optical drive.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
4. Click Intel® I350-AM2/I210 Gigabit Adapters Driver in the Drivers menu of the main
screen to start the installation.
Z11PA-D8 Series 7-11
6. Click Next when the Intel(R)NetworkConnectionsInstallWizard window appears.
7. Tick Iacceptthetermsinthelicenseagreement and click Next to continue.
8. From the Setup Options window, click Next to start the installation.
By default, Intel(R)PROSetforWindowsDeviceManager and Windows PowerShell
Module are ticked.
7-12 Chapter 7: Driver Installation
9. Click Install to start the installation.
10. When the installation is done, press Finish to complete the installation.
Z11PA-D8 Series 7-13
7.6 VGAdriverinstallation
This section provides the instructions on how to install the ASPEED Video Graphics Adapter
(VGA) driver.
You need to manually install the ASPEED VGA driver on a Windows® operating system.
To install the ASPEED VGA driver:
1. Restart the computer, and then log on with Administrator privileges.
2. Insert the motherboard/system support DVD into the optical drive. The support DVD
automatically displays the Drivers menu if Autorun is enabled in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
3. Click the ASPEEDAST2500DisplayDriver to begin installation.
4. From the installation window, click Next to start the installation.
7-14 Chapter 7: Driver Installation
6. Click Finishto complete the installation.
5. Click Install to start the installation process.
Z11PA-D8 Series 7-15
7.7 Intel®RapidStorageTechnologyenterprise5.0
installation
This section provides the instructions on how to install the Intel® Rapid Storage Technology
enterprise 5.0 on the system.
You need to manually install the Intel® Rapid Storage Technology enterprise 5.0 utility on a
Windows® operating system.
To install the Intel® Rapid Storage Technology enterprise 5.0 utility:
1. Restart the computer, and then log on with Administrator privileges.
2. Insert the motherboard/system support DVD into the optical drive, and navigate to the
Utilities menu.
3. Click the Intel®RapidStorageTechnologyenterprise to begin installation.
4. The Intel®RapidStorageTechnologyenterprise window appears. Click Next to start
the installation.
7-16 Chapter 7: Driver Installation
5. Read the Warning message and click Next to continue.
6. Read the LicenseAgreement and click Accept to continue the process.
7. Select the destination folder and click Next to continue.
Z11PA-D8 Series 7-17
8. Tick the features that you would like to install and click Next to continue.
9. Click Install to start the installation process.
10. Click RestartNow to complete the setup process.
7-18 Chapter 7: Driver Installation
A
Appendix
This appendix includes additional information that you may
refer to when conguring the motherboard.
Appendix
A-2 Appendix
Z11PA-D8 Series block diagram
(with SATA M.2 device)
Z11PA-D8 Series block diagram
(without SATA M.2 device)
Z11PA-D8 Series A-3
Q-Code table
Action PHASE POST CODE TYPE DESCRIPTION
Normal boot
Security Phase
01 Progress First post code(POWER_ON_POST_CODE)
02 Progress Load BSP microcode(MICROCODE_POST_CODE)
03 Progress Set cache as ram for PEI phase(CACHE_ENABLED_POST_CODE)
06 Progress CPU Early init.(CPU_EARLY_INIT_POST_CODE)
04 Progress initializes South bridge for PEI preparation
PEI (Pre-EFI
initialization) phase
10 Progress PEI Core Entry
15 Progress NB initialize before installed memory
19 Progress SB initialize before installed memory
78~00 Progress Wait BMC ready(duration: 120 seconds)
A1 MRC Progress QPI initialization
A3 MRC Progress QPI initialization
A7 MRC Progress QPI initialization
A8 MRC Progress QPI initialization
A9 MRC Progress QPI initialization
AA MRC Progress QPI initialization
AB MRC Progress QPI initialization
AC MRC Progress QPI initialization
AD MRC Progress QPI initialization
AE MRC Progress QPI initialization
AF MRC Progress QPI initialization Complete
2F Progress Memory Init.
B0 MRC Progress Memory Init.
B1 MRC Progress Memory Init.
AF MRC Progress RC Reset if require
B4 MRC Progress Memory Init.
B2 MRC Progress Memory Init.
B3 MRC Progress Memory Init.
B5 MRC Progress Memory Init.
B6 MRC Progress Memory Init.
B7 MRC Progress Memory Init.
B8 MRC Progress Memory Init.
B9 MRC Progress Memory Init.
BA MRC Progress Memory Init.
BB MRC Progress Memory Init.
BC MRC Progress Memory Init.
BF MRC Progress Memory Init. Done
5A MRC Progress Other cong. After RC end
31 Progress Memory already installed
32 Progress CPU Init.
34 Progress CPU Init.
36 Progress CPU Init.
4F Progress DXE Initial Program Load(IPL)
(continued on the next page)
A-4 Appendix
Action PHASE POST CODE TYPE DESCRIPTION
Normal boot
DXE (Driver
Execution
Environment) phase
60 Progress DXE Core Started
61 Progress DXE NVRAM Init.
62 Progress SB run-time init.
63 Progress DXE CPU Init
68 Progress NB Init.
69 Progress NB Init.
6A Progress NB Init.
70 Progress SB Init.
71 Progress SB Init.
72 Progress SB Init.
78 Progress ACPI Init.
79 Progress CSM Init.
BDS (Boot Device
Selection) phase
90 Progress BDS started
91 Progress Connect device event
92 Progress PCI Bus Enumeration.
93 Progress PCI Bus Enumeration.
94 Progress PCI Bus Enumeration.
95 Progress PCI Bus Enumeration.
96 Progress PCI Bus Enumeration.
97 Progress Console outout connect event
98 Progress Console input connect event
99 Progress AMI Super IO start
9A Progress AMI USB Driver Init.
9B Progress AMI USB Driver Init.
9C Progress AMI USB Driver Init.
9D Progress AMI USB Driver Init.
b2 Progress Legacy Option ROM Init.
b3 Progress Reset system
b4 Progress USB hotplug
b6 Progress NVRAM clean up
b7 Progress NVRAM conguration reset
A0 Progress IDE, AHCI Init.
A1 Progress IDE, AHCI Init.
A2 Progress IDE, AHCI Init.
A3 Progress IDE, AHCI Init.
A8 Progress BIOS Setup Utility password verify
A9 Progress BIOS Setup Utility start
AB Progress BIOS Setup Utility input wait
AD Progress Ready to boot event
AE Progress Legacy boot event
Operating system
phase
AA Progress APIC mode
AC Progress PIC mode
Q-Code table
Z11PA-D8 Series A-5
Notices
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with manufacturer’s instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
The use of shielded cables for connection of the monitor to the graphics card is required
to assure compliance with FCC regulations. Changes or modifications to this unit not
expressly approved by the party responsible for compliance could void the user’s authority
to operate this equipment.
Compliance Statement of Innovation, Science and Economic
Development Canada (ISED)
This device complies with Innovation, Science and Economic Development Canada licence
exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
CAN ICES-3(B)/NMB-3(B)
Déclaration de conformité de Innovation, Sciences et
Développement économique Canada (ISED)
Le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement
économique Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
CAN ICES-3(B)/NMB-3(B)
A-6 Appendix
Australia statement notice
From 1 January 2012 updated warranties apply to all ASUS products, consistent with
the Australian Consumer Law. For the latest product warranty details please visit
https://www.asus.com/support. Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality
and the failure does not amount to a major failure.
If you require assistance please call ASUS Customer Service 1300 2787 88 or visit us at
https://www.asus.com/support.
Declaration of compliance for product environmental regulation
ASUS follows the green design concept to design and manufacture our products, and
makes sure that each stage of the product life cycle of ASUS product is in line with global
environmental regulations. In addition, ASUS disclose the relevant information based on
regulation requirements.
Please refer to http://csr.asus.com/Compliance.htm for information disclosure based on
regulation requirements ASUS is complied with:
EU REACH and Article 33
Complying with the REACH (Registration, Evaluation, Authorisation, and Restriction of
Chemicals) regulatory framework, we published the chemical substances in our products at
ASUS REACH website at http://csr.asus.com/english/REACH.htm.
EU RoHS
This product complies with the EU RoHS Directive. For more details, see
http://csr.asus.com/english/article.aspx?id=35
India RoHS
This product complies with the “India E-Waste (Management) Rules, 2016” and prohibits
use of lead, mercury, hexavalent chromium, polybrominated biphenyls (PBBs) and
polybrominated diphenyl ethers (PBDEs) in concentrations exceeding 0.1% by weight in
homogenous materials and 0.01% by weight in homogenous materials for cadmium, except
for the exemptions listed in Schedule II of the Rule.
Vietnam RoHS
ASUS products sold in Vietnam, on or after September 23, 2011,meet the requirements of
the Vietnam Circular 30/2011/TT-BCT.
Các sản phẩm ASUS bán tại Việt Nam, vào ngày 23 tháng 9 năm2011 trở về sau, đều phải
đáp ứng các yêu cầu của Thông tư 30/2011/TT-BCT của Việt Nam.
Turkey RoHS
AEEE Yönetmeliğine Uygundur
Z11PA-D8 Series A-7
ASUS Recycling/Takeback Services
ASUS recycling and takeback programs come from our commitment to the highest standards
for protecting our environment. We believe in providing solutions for you to be able to
responsibly recycle our products, batteries, other components as well as the packaging
materials. Please go to http://csr.asus.com/english/Takeback.htm for detailed recycling
information in different regions.
DO NOT throw the motherboard in municipal waste. This product has been designed to enable
proper reuse of parts and recycling. This symbol of the crossed out wheeled bin indicates that the
product (electrical and electronic equipment) should not be placed in municipal waste. Check local
regulations for disposal of electronic products.
DO NOT throw the mercury-containing button cell battery in municipal waste. This symbol of
the crossed out wheeled bin indicates that the battery should not be placed in municipal waste.
A-8 Appendix
Română ASUSTeK Computer Inc. declară că acest dispozitiv se conformează
cerinţelor esenţiale şi altor prevederi relevante ale directivelor conexe. Textul
complet al declaraţiei de conformitate a Uniunii Europene se găseşte la:
www.asus.com/support
Srpski ASUSTeK Computer Inc. ovim izjavljuje da je ovaj uređaj u saglasnosti
sa osnovnim zahtevima i drugim relevantnim odredbama povezanih
Direktiva. Pun tekst EU deklaracije o usaglašenosti je dostupan da adresi:
www.asus.com/support
Slovensky Spoločnosť ASUSTeK Computer Inc. týmto vyhlasuje, že toto
zariadenie vyhovuje základným požiadavkám a ostatým príslušným
ustanoveniam príslušných smerníc. Celý text vyhlásenia o zhode pre štáty EÚ
je dostupný na adrese: www.asus.com/support
Slovenščina ASUSTeK Computer Inc. izjavlja, da je ta naprava skladna z
bistvenimi zahtevami in drugimi ustreznimi določbami povezanih direktiv.
Celotno besedilo EU-izjave o skladnosti je na voljo na spletnem mestu:
www.asus.com/support
Español Por la presente, ASUSTeK Computer Inc. declara que este dispositivo
cumple los requisitos básicos y otras disposiciones pertinentes de las
directivas relacionadas. El texto completo de la declaración de la UE de
conformidad está disponible en: www.asus.com/support
Svenska ASUSTeK Computer Inc. förklarar härmed att denna
enhet överensstämmer med de grundläggande kraven och andra
relevanta föreskrifter i relaterade direktiv. Fulltext av EU-försäkran om
överensstämmelse nns på: www.asus.com/support
Українська ASUSTeK Computer Inc. заявляє, що цей пристрій відповідає
основним вимогам та іншим відповідним положенням відповідних
Директив. Повний текст декларації відповідності стандартам ЄС
доступний на: www.asus.com/support
Türkçe AsusTek Computer Inc., bu aygıtın temel gereksinimlerle ve
ilişkili Yönergelerin diğer ilgili koşullarıyla uyumlu olduğunu beyan
eder. AB uygunluk bildiriminin tam metni şu adreste bulunabilir:
www.asus.com/support
Bosanski ASUSTeK Computer Inc. ovim izjavljuje da je ovaj uređaj usklađen
sa bitnim zahtjevima i ostalim odgovarajućim odredbama vezanih direktiva.
Cijeli tekst EU izjave o usklađenosti dostupan je na: www.asus.com/support
English ASUSTeK Computer Inc. hereby declares that this device is in
compliance with the essential requirements and other relevant provisions
of related Directives. Full text of EU declaration of conformity is available at:
www.asus.com/support
Français AsusTek Computer Inc. déclare par la présente que cet appareil est
conforme aux critères essentiels et autres clauses pertinentes des directives
concernées. La déclaration de conformité de l’UE peut être téléchargée à
partir du site Internet suivant : www.asus.com/support
Deutsch ASUSTeK Computer Inc. erklärt hiermit, dass dieses Gerät mit
den wesentlichen Anforderungen und anderen relevanten Bestimmungen
der zugehörigen Richtlinien übereinstimmt. Der gesamte Text der EU-
Konformitätserklärung ist verfügbar unter: www.asus.com/support
Italiano ASUSTeK Computer Inc. con la presente dichiara che questo
dispositivo è conforme ai requisiti essenziali e alle altre disposizioni pertinenti
con le direttive correlate. Il testo completo della dichiarazione di conformità
UE è disponibile all’indirizzo: www.asus.com/support
Русский Компания ASUS заявляет, что это устройство соответствует
основным требованиям и другим соответствующим условиям
соответствующих директив. Подробную информацию, пожалуйста,
смотрите на www.asus.com/support
Български С настоящото ASUSTeK Computer Inc. декларира, че
това устройство е в съответствие със съществените изисквания и
другите приложими постановления на свързаните директиви. Пълният
текст на декларацията за съответствие на ЕС е достъпна на адрес:
www.asus.com/support
Hrvatski ASUSTeK Computer Inc. ovim izjavljuje da je ovaj uređaj sukladan
s bitnim zahtjevima i ostalim odgovarajućim odredbama vezanih direktiva.
Cijeli tekst EU izjave o sukladnosti dostupan je na: www.asus.com/support
Čeština Společnost ASUSTeK Computer Inc. tímto prohlašuje, že toto
zařízení splňuje základní požadavky a další příslušná ustanovení souvisejících
směrnic. Plné znění prohlášení o shodě EU je k dispozici na adrese:
www.asus.com/support
Dansk ASUSTeK Computer Inc. erklærer hermed, at denne enhed er i
overensstemmelse med hovedkravene og andre relevante bestemmelser i de
relaterede direktiver. Hele EU-overensstemmelseserklæringen kan ndes på:
www.asus.com/support
Nederlands ASUSTeK Computer Inc. verklaart hierbij dat dit apparaat
voldoet aan de essentiële vereisten en andere relevante bepalingen van de
verwante richtlijnen. De volledige tekst van de EU-verklaring van conformiteit
is beschikbaar op: www.asus.com/support
Eesti Käesolevaga kinnitab ASUSTeK Computer Inc, et see seade vastab
asjakohaste direktiivide oluliste nõuetele ja teistele asjassepuutuvatele
sätetele. EL vastavusdeklaratsiooni täielik tekst on saadaval järgmisel
aadressil: www.asus.com/support
Suomi ASUSTeK Computer Inc. ilmoittaa täten, että tämä laite on
asiaankuuluvien direktiivien olennaisten vaatimusten ja muiden tätä
koskevien säädösten mukainen. EU-yhdenmukaisuusilmoituksen koko teksti
on luettavissa osoitteessa: www.asus.com/support
Ελληνικά Με το παρόν, η AsusTek Computer Inc. δηλώνει ότι αυτή η συσκευή
συμμορφώνεται με τις θεμελιώδεις απαιτήσεις και άλλες σχετικές διατάξεις
των Οδηγιών της ΕΕ. Το πλήρες κείμενο της δήλωσης συμβατότητας είναι
διαθέσιμο στη διεύθυνση: www.asus.com/support
Magyar Az ASUSTeK Computer Inc. ezennel kijelenti, hogy ez az eszköz
megfelel a kapcsolódó Irányelvek lényeges követelményeinek és egyéb
vonatkozó rendelkezéseinek. Az EU megfelelőségi nyilatkozat teljes szövege
innen letölthető: www.asus.com/support
Latviski ASUSTeK Computer Inc. ar šo paziņo, ka šī ierīce atbilst saistīto
Direktīvu būtiskajām prasībām un citiem citiem saistošajiem nosacījumiem.
Pilns ES atbilstības paziņojuma teksts pieejams šeit: www.asus.com/support
Lietuvių „ASUSTeK Computer Inc.“ šiuo tvirtina, kad šis įrenginys atitinka
pagrindinius reikalavimus ir kitas svarbias susijusių direktyvų nuostatas. Visą
ES atitikties deklaracijos tekstą galima rasti: www.asus.com/support
Norsk ASUSTeK Computer Inc. erklærer herved at denne enheten er i
samsvar med hovedsaklige krav og andre relevante forskrifter i relaterte
direktiver. Fullstendig tekst for EU-samsvarserklæringen finnes på:
www.asus.com/support
Polski Firma ASUSTeK Computer Inc. niniejszym oświadcza, że urządzenie to
jest zgodne z zasadniczymi wymogami i innymi właściwymi postanowieniami
powiązanych dyrektyw. Pełny tekst deklaracji zgodności UE jest dostępny pod
adresem: www.asus.com/support
Português A ASUSTeK Computer Inc. declara que este dispositivo está em
conformidade com os requisitos essenciais e outras disposições relevantes
das Diretivas relacionadas. Texto integral da declaração da UE disponível em:
www.asus.com/support
Simplied EU Declaration of Conformity
Z11PA-D8 Series A-9
ASUS contact information
ASUSTeK COMPUTER INC.
Address 4F, No. 150, Li-Te Rd., Peitou, Taipei 112, Taiwan
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
Web site https://www.asus.com
Technical Support
Telephone +86-21-38429911
Fax +86-21-58668722 ext: 9101
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=en
ASUSTeK COMPUTER INC. (Taiwan)
Address 4F, No. 150, Li-Te Rd., Peitou, Taipei 112, Taiwan
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
Web site https://www.asus.com/tw/
Technical Support
Telephone +886-2-2894-3447 (0800-093-456)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=zh-tw
ASUSTeK COMPUTER INC. (China)
Address No. 5077, Jindu Road, Minhang District, Shanghai, China
Telephone +86-21-5442-1616
Fax +86-21-5442-0099
Web site https://www.asus.com.cn
Technical Support
Telephone +86-20-2804-7506 (400-620-6655)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=zh-cn
A-10 Appendix
ASUS contact information
ASUS COMPUTER INTERNATIONAL (America)
Address 48720 Kato Rd., Fremont, CA 94538, USA
Fax +1-510-608-4555
Web site https://www.asus.com/us/
Technical Support
Support fax +1-812-284-0883
General support +1-812-282-2787
Online support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=en-us
ASUS COMPUTER GmbH (Germany and Austria)
Address Harkort Str. 21-23, 40880 Ratingen, Germany
Fax +49-2102-959911
Web site https://www.asus.com/de/
Technical Support
Telephone +49-1805-010923
Support Fax +49-2102-959911
Online support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=de-de
ASUS Czech Service s.r.o. (Europe)
Address Na Rovince 887, 720 00 Ostrava – Hrabová,
Czech Republic
Telephone +420-596766888
Web site https://www.asus.com/cz/
Technical Support
Telephone +420-596-766-891
Fax +420-596-766-329
E-mail advance.rma.eu@asus.com
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=cs-cz
Z11PA-D8 Series A-11
ASUS contact information
ASUS Holland BV (The Netherlands)
Address Marconistraat 2, 7825GD EMMEN, The Netherlands
Web site https://www.asus.com/nl/
Technical Support
Telephone +31-(0)591-5-70292
Fax +31-(0)591-666853
E-mail advance.rma.eu@asus.com
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=nl-nl
ASUS Polska Sp. z o.o. (Poland)
Address Ul. Postępu 6, 02-676 Warszawa, Poland
Web site https://www.asus.com/pl/
Technical Support
Telephone +48-225718033
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=pl-pl
ASK-Service (Russia and CIS)
Address
г.Москва, ул. Орджоникидзе, д.10, Россия
Telephone (495) 640-32-75
Web site https://www.asus.com/ru/
Technical Support
Telephone 008-800-100-ASUS (008-800-100-2787)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=ru-ru
A-12 Appendix
FCC COMPLIANCE INFORMATION
Per FCC Part 2 Section 2.1077
Responsible Party:
Asus Computer International
Address: 48720 Kato Rd, Fremont, CA 94538
Phone/Fax No: (510)739-3777/(510)608-4555
hereby declares that the product
Product Name :
Motherboard
Model Number : Z11PA-D8
compliance statement:
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Ver. 180125