Table of Contents
- Notices
- Chapter 1: Product Introduction
- Chapter 2: Hardware Information
- Chapter 3: Powering Up
- Chapter 4: BIOS Setup
- 4.1 Managing and updating your BIOS
- 4.2 BIOS setup program
- 4.3 Main menu
- 4.4 Advanced menu
- 4.4.1 Trusted Computing
- 4.4.2 ACPI Settings
- 4.4.3 Smart Settings
- 4.4.4 Super IO Configuration
- 4.4.5 Serial Port Console Redirection
- 4.4.6 Onboard LAN
- 4.4.7 APM
- 4.4.8 PCI Subsystem Settings
- 4.4.9 Network Stack Configuration
- 4.4.10 CSM Configuration
- 4.4.11 NVMe Configuration
- 4.4.12 USB Configuration
- 4.4.13 iSCSI Configuration
- 4.4.14 Intel(R) Virtual RAID on CPU
- 4.5 Platform Configuration menu
- 4.6 Socket Configuration menu
- 4.7 Event Logs menu
- 4.8 Server Mgmt menu
- 4.9 Security menu
- 4.10 Boot menu
- 4.11 Tool menu
- 4.12 Save & Exit menu
- Chapter 5: RAID Configuration
- Chapter 6: Driver Installation
- Appendix
ASUS Z11PA-U12/10G-2S User Manual
Displayed below is the user manual for Z11PA-U12/10G-2S by ASUS which is a product in the Motherboards category. This manual has pages.
Related Manuals
Z11PA-U12 Series
User Guide
ii
E13901
Revised Edition V2
January 2018
Copyright © 2018 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language in any form or by any means,
except documentation kept by the purchaser for backup purposes, without the express written permission
of ASUSTeK COMPUTER INC. (“ASUS”).
Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless
such repair, modication of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS
DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS,
LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE),
EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY
DEFECT OR ERROR IN THIS MANUAL OR PRODUCT.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR
INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE,
AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. ASUS ASSUMES NO
RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS
MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identication or explanation and to the
owners’ benet, without intent to infringe.
iii
Contents
Notices ..................................................................................................................... viii
Federal Communications Commission Statement ........................................ viii
Canadian Department of Communications Statement ....................................ix
REACH .......................................................................................................ix
Safety information ....................................................................................................... x
Electrical safety ............................................................................................... x
Operation safety .............................................................................................. x
Australia statement notice ...............................................................................xi
How this guide is organized ...........................................................................xii
Where to nd more information ...................................................................... xii
Z11PA-U12 Series specifications summary........................................................... xiv
Chapter 1: Product Introduction
1.1 Welcome! ....................................................................................................1-2
1.2 Package contents ......................................................................................1-2
1.3 Serial number label .................................................................................... 1-3
1.4 Special features..........................................................................................1-3
1.4.1 Product highlights........................................................................1-3
1.4.2 Innovative ASUS features ........................................................... 1-4
Chapter 2: Hardware Information
2.1 Before you proceed ...................................................................................2-2
2.2 Motherboard overview ...............................................................................2-3
2.2.1 Placement direction.....................................................................2-3
2.2.2 Screw holes.................................................................................2-3
2.2.3 Motherboard layout ..................................................................... 2-4
2.2.4 Layout contents ........................................................................... 2-6
2.3 Central Processing Unit (CPU) .................................................................2-8
2.3.1 Installing the CPU and heatsink .................................................. 2-8
2.4 System memory .......................................................................................2-10
2.4.1 Overview ................................................................................... 2-10
2.4.2 Memory Congurations ............................................................. 2-10
2.4.3 Installing a DIMM on a single clip DIMM socket........................ 2-11
iv
Contents
2.5 Expansion slots ........................................................................................2-12
2.5.1 Installing an expansion card......................................................2-12
2.5.2 Conguring an expansion card ................................................. 2-12
2.5.3 Interrupt assignments................................................................2-13
2.5.4 PCI Express x16 slot (x16 link) ................................................. 2-13
2.5.5 PCI Express x8 slot (x8 link) ..................................................... 2-13
2.5.6 PCI Express x8 slot (x4 link) ..................................................... 2-13
2.6 Onboard LEDs .......................................................................................... 2-15
2.7 Jumpers ....................................................................................................2-19
2.8 Connectors ...............................................................................................2-25
2.8.1 Rear panel connectors .............................................................. 2-25
2.8.2 Internal connectors....................................................................2-27
Chapter 3: Powering Up
3.1 Starting up for the first time ......................................................................3-2
3.2 Powering off the computer ........................................................................3-3
3.2.1 Using the OS shut down function ................................................ 3-3
3.2.2 Using the dual function power switch .......................................... 3-3
Chapter 4: BIOS Setup
4.1 Managing and updating your BIOS ..........................................................4-2
4.1.1 ASUS CrashFree BIOS 3 utility................................................... 4-2
4.1.2 ASUS EzFlash Utility................................................................... 4-3
4.1.3 BUPDATER utility ....................................................................... 4-4
4.2 BIOS setup program ..................................................................................4-6
4.2.1 BIOS menu screen ...................................................................... 4-7
4.2.2 Menu bar ..................................................................................... 4-7
4.2.3 Menu items..................................................................................4-8
4.2.4 Submenu items ........................................................................... 4-8
4.2.5 Navigation keys ........................................................................... 4-8
4.2.6 General help................................................................................4-8
4.2.7 Conguration elds ..................................................................... 4-8
4.2.8 Pop-up window............................................................................4-8
4.2.9 Scroll bar ..................................................................................... 4-8
4.3 Main menu ..................................................................................................4-9
4.3.1 System Date [Day xx/xx/xxxx] ..................................................... 4-9
4.3.2 System Time [xx:xx:xx] ............................................................... 4-9
v
Contents
4.4 Advanced menu .......................................................................................4-10
4.4.1 Trusted Computing.................................................................... 4-10
4.4.2 ACPI Settings ............................................................................ 4-11
4.4.3 Smart Settings...........................................................................4-11
4.4.4 Super IO Conguration ............................................................. 4-12
4.4.5 Serial Port Console Redirection ................................................ 4-12
4.4.6 Onboard LAN ............................................................................ 4-15
4.4.7 APM .......................................................................................... 4-17
4.4.8 PCI Subsystem Settings ........................................................... 4-18
4.4.9 Network Stack Conguration..................................................... 4-22
4.4.10 CSM Conguration .................................................................... 4-23
4.4.11 NVMe Conguration .................................................................. 4-24
4.4.12 USB Conguration .................................................................... 4-24
4.4.13 iSCSI Conguration .................................................................. 4-25
4.4.14 Intel(R) Virtual RAID on CPU .................................................... 4-25
4.5 Platform Configuration menu .................................................................4-26
4.5.1 PCH Conguration .................................................................... 4-26
4.5.2 Miscellaneous Conguration ..................................................... 4-29
4.5.3 Server ME Conguration ........................................................... 4-29
4.5.4 Runtime Error Logging .............................................................. 4-30
4.6 Socket Configuration menu ....................................................................4-31
4.6.1 Processor Conguration............................................................ 4-31
4.6.2 Common RefCode Conguration .............................................. 4-33
4.6.3 UPI Conguration ...................................................................... 4-33
4.6.4 Memory Conguration ............................................................... 4-34
4.6.5 IIO Conguration ....................................................................... 4-35
4.6.6 Advanced Power Management Conguration........................... 4-36
4.7 Event Logs menu .....................................................................................4-39
4.7.1 Change Smbios Event Log Settings ......................................... 4-39
4.7.2 View Smbios Event Log ............................................................ 4-39
4.8 Server Mgmt menu ...................................................................................4-40
4.8.1 System Event Log ..................................................................... 4-40
4.8.2 BMC network conguration ....................................................... 4-41
4.8.3 View System Event Log ............................................................ 4-42
4.9 Security menu ..........................................................................................4-43
4.10 Boot menu ................................................................................................4-46
4.11 Tool menu ................................................................................................. 4-47
4.12 Save & Exit menu ..................................................................................... 4-47
vi
Contents
Chapter 5: RAID Configuration
5.1 RAID configurations ..................................................................................5-2
5.1.1 RAID denitions .......................................................................... 5-2
5.1.2 Installing Serial ATA hard disks .................................................. 5-3
5.1.3 Setting the RAID item in BIOS .................................................... 5-3
5.1.4 RAID conguration utilities .......................................................... 5-3
5.2 Intel® Rapid Storage Technology enterprise SATA/SSATA
Option ROM Utility .....................................................................................5-4
5.2.1 Creating a RAID set .................................................................... 5-5
5.2.2 Deleting a RAID set.....................................................................5-7
5.2.3 Resetting disks to Non-RAID ...................................................... 5-8
5.2.4 Exiting the Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM utility ................................................ 5-9
5.2.5 Rebuilding the RAID....................................................................5-9
5.2.6 Setting the Boot array in the BIOS Setup Utility ........................ 5-11
5.3 Intel® Rapid Storage Technology enterprise (Windows) ......................5-12
5.3.1 Creating a RAID set .................................................................. 5-13
5.3.2 Changing a Volume Type..........................................................5-15
5.3.3 Deleting a volume ..................................................................... 5-16
5.3.4 Preferences ............................................................................... 5-17
5.4 Intel® Virtual Raid on CPU in BIOS ......................................................... 5-18
5.4.1 Creating a RAID set .................................................................. 5-19
5.4.2 Deleting a RAID set...................................................................5-21
5.4.3 Installing the RAID controller driver during Windows® 10 OS
installation ................................................................................. 5-22
Chapter 6: Driver Installation
6.1 RAID driver installation .............................................................................6-2
6.1.1 Creating a USB ash drive with RAID drive ................................ 6-2
6.1.2 Installing the RAID controller driver............................................. 6-2
6.2 Management applications and utilities installation ................................6-5
6.3 Running the Support DVD .........................................................................6-5
6.4 Intel® chipset device software installation ..............................................6-8
6.5 Installing the Intel® I210 Gigabit Adapters driver ..................................6-10
6.7 Intel® Rapid Storage Technology enterprise 5.0 installation ............... 6-13
vii
Contents
Appendix
Z11PA-U12 Series block diagram .......................................................................... A-2
Z11PA-U12/10G-2S .....................................................................................A-2
Z11PA-U12 ..................................................................................................A-3
Q-Code table ............................................................................................................ A-4
Simplified EU Declaration of Conformity .............................................................. A-6
ASUS contact information ...................................................................................... A-7
viii
Notices
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received including interference that may cause
undesired operation.
Z11PA-U12/10G-2S
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Z11PA-U12
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with manufacturer’s instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
The use of shielded cables for connection of the monitor to the graphics card is required
to assure compliance with FCC regulations. Changes or modications to this unit not
expressly approved by the party responsible for compliance could void the user’s authority
to operate this equipment.
ix
REACH
Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of
Chemicals) regulatory framework, we publish the chemical substances in our products at
ASUS REACH website at http://csr.asus.com/english/REACH.htm.
Compliance Statement of Innovation, Science and Economic
Development Canada (ISED)
This device complies with Innovation, Science and Economic Development Canada licence
exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device
may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Z11PA-U12/10G-2S: CAN ICES-3(A)/NMB-3(A)
Z11PA-U12/10G-2S: CAN ICES-3(B)/NMB-3(B)
Déclaration de conformité de Innovation, Sciences et
Développement économique Canada (ISED)
Le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement
économique Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
Z11PA-U12/10G-2S: CAN ICES-3(A)/NMB-3(A)
Z11PA-U12/10G-2S: CAN ICES-3(B)/NMB-3(B)
x
Safety information
Electrical safety
• To prevent electrical shock hazard, disconnect the power cable from the electrical outlet
before relocating the system.
• When adding or removing devices to or from the system, ensure that the power cables
for the devices are unplugged before the signal cables are connected. If possible,
disconnect all power cables from the existing system before you add a device.
• Before connecting or removing signal cables from the motherboard, ensure that all power
cables are unplugged.
• Seek professional assistance before using an adapter or extension cord. These devices
could interrupt the grounding circuit.
• Make sure that your power supply is set to the correct voltage in your area. If you are
not sure about the voltage of the electrical outlet you are using, contact your local power
company.
• If the power supply is broken, do not try to x it by yourself. Contact a qualied service
technician or your retailer.
Operation safety
• Before installing the motherboard and adding devices on it, carefully read all the manuals
that came with the package.
• Before using the product, make sure all cables are correctly connected and the power
cables are not damaged. If you detect any damage, contact your dealer immediately.
• To avoid short circuits, keep paper clips, screws, and staples away from connectors,
slots, sockets and circuitry.
• Avoid dust, humidity, and temperature extremes. Do not place the product in any area
where it may become wet.
• Place the product on a stable surface.
• If you encounter technical problems with the product, contact a qualied service
technician or your retailer.
DO NOT throw the motherboard in municipal waste. This product has been designed to
enable proper reuse of parts and recycling. This symbol of the crossed out wheeled bin
indicates that the product (electrical and electronic equipment) should not be placed in
municipal waste. Check local regulations for disposal of electronic products.
DO NOT throw the mercury-containing button cell battery in municipal waste. This symbol
of the crossed out wheeled bin indicates that the battery should not be placed in municipal
waste.
xi
Australia statement notice
From 1 January 2012 updated warranties apply to all ASUS products, consistent with the
Australian Consumer Law. For the latest product warranty details please visit
https://www.asus.com/support. Our goods come with guarantees that cannot be excluded
under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality
and the failure does not amount to a major failure.
If you require assistance please call ASUS Customer Service 1300 2787 88 or visit us at
https://www.asus.com/support.
xii
About this guide
This user guide contains the information you need when installing and conguring the
motherboard.
How this guide is organized
This user guide contains the following parts:
• Chapter1:ProductIntroduction
This chapter describes the features of the motherboard and the new technologies it
supports.
• Chapter2:HardwareInformation
This chapter lists the hardware setup procedures that you have to perform when
installing system components. It includes description of the switches, jumpers, and
connectors on the motherboard.
• Chapter3:PoweringUp
This chapter describes the power up sequence and ways of shutting down the system.
• Chapter4:BIOSSetup
This chapter tells how to change system settings through the BIOS Setup menus.
Detailed descriptions of the BIOS parameters are also provided.
• Chapter5:RAIDConfiguration
This chapter provides instructions for setting up, creating, and conguring RAID sets
using the available utilities.
• Chapter6:DriverInstallation
This chapter provides instructions for installing the necessary drivers for different
system components.
• Appendix:ReferenceInformation
This appendix includes additional information that you may refer to when conguring
the motherboard.
Where to find more information
Refer to the following sources for additional information and for product and software updates.
1. ASUS websites
The ASUS website provides updated information on ASUS hardware and software
products. Refer to the ASUS contact information.
2. Optional documentation
Your product package may include optional documentation, such as warranty yers,
that may have been added by your dealer. These documents are not part of the
standard package.
xiii
Conventions used in this guide
To ensure that you perform certain tasks properly, take note of the following symbols used
throughout this manual.
DANGER/WARNING: Information to prevent injury to yourself when trying to
complete a task.
CAUTION: Information to prevent damage to the components when trying to
complete a task.
IMPORTANT: Instructions that you MUST follow to complete a task.
NOTE: Tips and additional information to help you complete a task.
Typography
Bold text Indicates a menu or an item to select.
Italics Used to emphasize a word or a phrase.
<Key> Keys enclosed in the less-than and greater-than sign means
that you must press the enclosed key.
Example: <Enter> means that you must press the Enter or
Return key.
<Key1> + <Key2> + <Key3> If you must press two or more keys simultaneously, the key
names are linked with a plus sign (+).
Example: <Ctrl> + <Alt> + <Del>
Command Means that you must type the command exactly as shown,
then supply the required item or value enclosed in brackets.
Example: At DOS prompt, type the command line:
format A:/S
xiv
Z11PA-U12 Series specifications summary
(continued on the next page)
Model Name Z11PA-U12/10G-2S Z11PA-U12
Processor Support /
System Bus
1 x Socket P0 (LGA 3647)
Intel® Xeon® processor Scalable Family - Skylake
Core Logic Intel® C622 PCH Intel® C621 PCH
Form Factor ATX, 12" x 9.6" (EEB Mounting Hole Locations)
ASUS
Features
Fan Speed
Control
Rack Ready
(Rack and
Pedestal dual
use)
ASUS Control
Center
Memory
Total Slots 12 (6-channel per CPU, 12 DIMM per CPU)
Voltage 1.2 V
Capacity Maximum up to 1536GB
Memory Type
DDR4 2666 / 2400 / 2133 RDIMM / LRDIMM / 3DS DIMM
* Refer to www.asus.com for the latest memory AVL update
Memory Size
4GB, 8GB, 16GB, 32GB (RDIMM)
32GB, 64GB (LRDIMM)
64GB, 128GB (LRDIMM 3DS)
Expansion
Slots (follow
SSI Location
number)
Total PCI / PCI-E
Slots 4
Slot Location 1 1 x PCI-E x8 (x4 Gen3 Link)
Slot Location 2 1 x PCI-E x16 (x16 Gen3 Link)
Slot Location 3 1 x PCI-E x8 (x8 Gen3 Link)
Slot Location 4 1 x PCI-E x16 (x16 Gen3 Link)
(Auto switch to x8 Gen3 Link if slot 3 is occupied) (support riser)
Additional Slot 1 M.2(NGFF) support (PCIe x2 Gen3 Link or SATA x1))
Additional Slot 2 Oculink connectors support (PCIe x4 Gen3 on each slot)
Networking LAN
2 x Intel I210AT
2 x 10G SFP+ LAN
(10G SKU only)
1 x Management Port with
2 x USB 2.0 ports
2 x Intel I210AT
1 x Management Port with
2 x USB 2.0 ports
Storage
SATA Controller
Intel® C620 series
13 x SATA 6Gb/s ports (3 x mini SAS HD + 1 x SATA)
1 x M.2 (PCIe x2 Gen3 Link or SATA x1) connector ;
NGFF Type 2280
SAS Upgrade
Optional kits:
ASUS PIKE II 3008 8-port SAS 12G RAID card
ASUS PIKE II 3108 8-port SAS 12G HW RAID card
xv
* Specifications are subject to change without notice.
Z11PA-U12 Series specifications summary
Model Name Z11PA-U12/10G-2S Z11PA-U12
Graphic VGA Aspeed AST2500 64MB
Onboard I/O
Connectors
TPM Header 1
PSU Connector 24-pin SSI power connector + 8-pin SSI 12V
Management
connector Onboard ASMB9-iKVM
USB Connectors 1 x USB 3.0 pin header (up to 2 devices)
1 x USB 2.0 pin header (up to 2 devices)
Fan Header 6 x 4-pin
SMBus 1
Chassis Intruder 1
Front LAN LED 2
Serial Port Header 1
M.2 Connector 1 x NGFF Type 2242, 2260, 2280
VROC Key Header 1
Rear I/O
Connectors
VGA Port 1
External USB Port 2 x USB 3.0 ports
SFP+ 2 x SFP+ —
RJ-45 2 x GbE LAN
1 x Mgmt LAN
Management
Solution
Software ASUS Control Center
Out of Band
Remote
Management
ASMB9-iKVM for KVM-over-Internet
Monitoring CPU Temperature
FAN RPM
Environment
Operation temperature: 10°C ~ 35°C
Non operation temperature: -40°C ~ 70°C
Non operation humidity: 20% ~ 90% (Non condensing)
xvi
1
Product Introduction
This chapter describes the motherboard features and the new
technologies it supports.
Chapter 1: Product Introduction
1-2 Chapter 1: Product Introduction
1.1 Welcome!
Congratulations and thank you for buying an ASUS® Z11PA-U12 Series motherboard!
The motherboard delivers a host of new features and latest technologies, making it another
standout in the long line of ASUS quality motherboards!
Before you start installing the motherboard and hardware devices on it, check the items in
your package with the list below.
1.2 Package contents
Check your motherboard package for the following items.
If any of the above items is damaged or missing, contact your retailer.
Standard Gift Box Pack Standard Bulk Pack
I/O Shield 1 1
SATA 6G cable 1 -
Application CD Support DVD 1 1 piece per carton
Packaging Quantity 1 piece per carton 10 pieces per carton
Optional items Description
PIKE II 3008 LSI 8-port SAS 12G RAID card
PIKE II 3108 LSI 8-port SAS 12G HW RAID card
PEM-FDR Mellanox ConnectX-3 FDR card
PEB-10G/57840-2S Dual port 10G SFP+ Ethernet Adapter
PEB-10G/57811-1S Single port 10G SFP+ Ethernet Adapter
Z11PA-U12 Series 1-3
1.4 Special features
1.4.1 Product highlights
Latest Processor Technology
The motherboard supports Intel Xeon® processor scalable family which provides compelling
IPC increases for legacy performance improvements, oating point improvement, easier
multi-core programming, and with next-generation processor power management.
Intel® AVX 512
Intel® AVX 512 extends 512-bit vector support for integer vector operations, doubles
xed point arithmetic throughput, adds support for new vector gather, permutes/blend,
vector shifts resulting in xed and oating-point algorithm improvements. Also, Intel's new
microarchitecture doubles the cache bandwidth at L1/L2 to support higher FLOPS and
contributes to greater performance in signal and image processing applications.
Next Generation of processor power management
Intel® Xeon processor scalable family enhances the processor power management with the
features of Energy Efcient Turbo, Uncore Frequency Scaling, and Per-Core P-state. Also,
the Integrated Voltage Regulator enables generational performance and power improvements
that the standard VR solutions cannot provide.
DDR4 memory support
The motherboard supports DDR4 memory that features faster clock frequencies and higher
data transfer rates of 2133 MT/s to 2666 MT/s (million transfers per second). DDR4 offers a
lower voltage standard of 1.2V that reduces memory power demand and provides improved
performance.
1.3 Serial number label
Before requesting support from the ASUS Technical Support team, you must take note of
the motherboard's serial number containing 12 characters xxS2xxxxxxxx shown in the gure
below. With the correct serial number of the product, ASUS Technical Support team members
can then offer a quicker and satisfying solution to your problems.
xxS2xxxxxxxx
Z11PA-U12 Series Made
in
China
合格
1-4 Chapter 1: Product Introduction
M.2 Support
This motherboard features the M.2 slot, which shares bandwidth with the SATA 6Gb/s port
and is dedicated to the operating system.
PCI Express 3.0
PCI Express 3.0 (PCIe 3.0) is the PCI Express bus standard that provides an optimal
graphics performance, unprecedented data speed, and seamless transition with its complete
backward compatibility to PCIe 2.0 devices.
Intel® I210AT LAN Solution
The motherboard comes with two Gigabit LAN controllers and ports which provide a total
solution for your networking needs. The onboard Intel® I210AT Gigabit LAN controllers use
the PCI Express interface and could achieve network throughput close to Gigabit bandwidth.
Intel® C620 Series Chipset
The Intel® C620 series chipset supports with enterprise class features which is targeted for
Cloud and Storage applications. It is optimized and validated to work with the latest Xeon®
processor scalable family, compared with the last generation, it also reduces the TDP,
supports USB 3.0 with up to 14 ports for SATA and SSATA thus bringing more features and
benets to the target users.
Serial ATA III technology
The motherboard supports the Serial ATA III technology through the Serial ATA interface
and Intel® C621 / C622 chipset, delivering up to 6 Gb/s data transfer rates. It also provides
enhanced scalability, faster data retrieval, and double the bandwidth of current bus systems.
Temperature, fan, and voltage monitoring
The CPU temperature is monitored to prevent overheating and damage. The system fan
rotations per minute (RPM) is monitored for timely failure detection. The chip monitors the
voltage levels to ensure a stable supply of current for critical components.
1.4.2 Innovative ASUS features
ASUS Fan Speed control technology
The ASUS Fan Speed control technology smartly adjusts the fan speeds according to the
system loading to ensure a quiet, cool, and efcient operation.
2
Hardware Information
This chapter lists the hardware setup procedures that you have
to perform when installing system components. It includes
description of the jumpers and connectors on the motherboard.
Chapter 2: Hardware Information
2-2 Chapter 2: Hardware Information
2.1 Before you proceed
Take note of the following precautions before you install any motherboard component or
change any motherboard settings.
• Unplugthepowercordfromthewallsocketbeforetouchinganycomponent.
• Useagroundedwriststraportouchasafelygroundedobjectorametalobject,such
asthepowersupplycase,beforehandlingcomponentstoavoiddamagingthemdue
to static electricity.
• HoldcomponentsbytheedgestoavoidtouchingtheICsonthem.
• Wheneveryouuninstallanycomponent,placeitonagroundedantistaticpadorinthe
bag that came with the component.
• Beforeyouinstallorremoveanycomponent,ensurethatthepowersupplyisswitched
off or the power cord is detached from the power supply. Failure to do so may cause
severedamagetothemotherboard,peripherals,and/orcomponents.
2-3
Z11PA-U12 Series
2.2 Motherboard overview
Beforeyouinstallthemotherboard,studythecongurationofyourchassistoensurethatthe
motherboardtsintoit.
Tooptimizethefeaturesofyourmotherboard,wehighlyrecommendthatyouinstallitinan
ATX 2.2 compliant chassis.
2.2.1 Placement direction
Wheninstallingthemotherboard,ensurethatyouplaceitintothechassisinthecorrect
orientation. The edge with external ports goes to the rear part of the chassis as indicated in
the image below.
2.2.2 Screw holes
Place nine (9) screws into the holes indicated by circles to secure the motherboard to the
chassis.
DO NOT overtighten the screws! Doing so can damage the motherboard.
Ensure to unplug the chassis power cord before installing or removing the motherboard.
Failure to do so can cause you physical injury and damage motherboard components!
Place this side towards
the rear of the chassis
2-4 Chapter 2: Hardware Information
2.2.3 Motherboard layout
Z11PA-U12/10G-2S
2-5
Z11PA-U12 Series
Z11PA-U12
2-6 Chapter 2: Hardware Information
2.2.4 Layout contents
Slots/Sockets Page
1. CPUsocket 2-8
2. DDR4 sockets 2-10
3. PCIExpressx16/PCIExpressx8 2-12
Onboard LEDs Page
1. StandbyPowerLED(SBPWR1) 2-16
2. BaseboardManagementControllerLED(BMCLED1) 2-16
3. CATTLED(CATERR1) 2-17
4. HarddiskactivityLED(HDDLED1) 2-17
5. MessageLED(MESLED1) 2-18
6. LocationLED(LOCLED1) 2-18
7. Q-CodeLEDs(PORT80_LED1) 2-19
Jumpers Page
1. ClearRTCRAM(CLRTC1) 2-19
2. VGAcontrollersetting(3-pinVGA_SW1) 2-20
3. LANcontrollersetting(3-pinLAN_SW1,LAN_SW2) 2-20
4. MErmwareforcerecoverysetting(3-pinME_RCVR1) 2-21
5. DDR4thermaleventsetting(3-pinDIMMTRIP1) 2-21
6. PCH_MFG1setting(3-pinPCH_MFG1) 2-22
7. SmartRideThrough(SmaRT)setting(3-pinSMART_PSU1) 2-22
8. DMLANsetting(3-pinDM_IP_SEL1) 2-23
9. IPMISWsetting(3-pinIPMI_SW1) 2-23
10. BaseboardManagementControllersetting(3-pinBMC_EN1) 2-24
2-7
Z11PA-U12 Series
Internal connectors Page
1. SerialATA6.0/3.0Gb/sconnector(7-pinSSATA1) 2-27
2. Mini-SASHDconnector(ISATA1-2;ISSATA1) 2-27
3. M.2(NGFF)connector(NGFF1) 2-28
4. TrustedPlatformModuleconnector(14-1pinTPM1) 2-28
5. USB2.0connector(10-1pinUSB56) 2-29
6. USB3.0connector(20-1pinUSB3_34) 2-29
7. PowerSupplySMBusconnector(5-pinPSUSMB1) 2-30
8. Serialportconnector(10-1pinCOM1) 2-30
9. CPU,front,andrearfanconnectors(4-pinCPU_FAN1,FRNT_FAN1-4,
REAR_FAN1) 2-31
10. HarddiskactivityLEDconnector(4-pinHDLED1) 2-31
11. EATXpowerconnectors(24-pinEATXPWR,8-pinEATX12V1) 2-32
12. LAN34_LEDconnector(5-1pinLAN34_LED1) 2-32
13. System panel connector (20-1 pin PANEL1) 2-33
14. Auxiliarypanelconnector(20-2pinAUX_PANEL1) 2-34
15. VPP_I2C1connector(10-1pinVPP_I2C1) 2-35
16. ChassisIntrusion(2-pinINTRUSION) 2-35
17. OCUPCIEconnectors(OCUPCIE1-2) 2-36
18. SystemManagementBus(SMBUS)connectors(5-1pinSMBUS1;
6-1pinSMBUS2) 2-36
19. SerialGeneralPurposeInput/Outputconnector(6-1pinSSGPIO1) 2-37
20. VGAconnector(16-pinVGA_HDR1) 2-37
21. VROC_KEYconnector(4-pinVROC_KEY1) 2-38
22. Thermal sensor cable connector (3-pin TR1) 2-38
2-8 Chapter 2: Hardware Information
2.3.1 Installing the CPU and heatsink
ToinstallaCPU:
1. LocatetheCPUsocketonthemotherboard.
2.3 Central Processing Unit (CPU)
The motherboard comes with a surface mount Socket P0 (LGA 3647) designed for the Intel®
Xeon® processor Skylake-SP product family.
• Uponpurchaseofthemotherboard,ensurethatthePnPcapisonthesocketand
thesocketcontactsarenotbent.ContactyourretailerimmediatelyifthePnPcap
ismissing,orifyouseeanydamagetothePnPcap/socketcontacts/motherboard
components.ASUSwillshoulderthecostofrepaironlyifthedamageisshipment/
transit-related.
• Keepthecapafterinstallingthemotherboard.ASUSwillprocessReturnMerchandise
Authorization(RMA)requestsonlyifthemotherboardcomeswiththecaponthe
Socket P0 (LGA 3647).
• Theproductwarrantydoesnotcoverdamagetothesocketcontactsresultingfrom
incorrectCPUinstallation/removal,ormisplacement/loss/incorrectremovalofthePnP
cap.
BeforeinstallingtheCPU,ensurethatthesocketboxisfacingtowardyouandthetriangle
mark is on the top-right position.
2. RemovethePNPcapfromtheCPUsocket.
2-9
Z11PA-U12 Series
3. AlignthetrianglemarkontheCPUwiththe
trianglemarkontheCPUCarrier(A),theninstall
theCPUintotheCPUCarrieruntilitclicksrmly
intoplace(B),andtheninstalltheCPUCarrier
intotheheatsinkuntilitclicksrmlyinplace(C).
EnsurethatthetrianglemarkontheCPU
matchesthetrianglemarkontheCPUCarrier.
ApplytheThermalInterfaceMaterialtotheCPU
heatsinkandCPUbeforeyouinstalltheheatsink
andfan,ifnecessary.
4. Twist each of the four screws with a screwdriver
just enough to attach the heatsink to the
motherboard.Whenthefourscrewsareattached,
tightenthemonebyoneinadiagonalsequence
to completely secure the heatsink.
CPU Carrier
CPU
Triangle mark
TheCPUandheatsinkassemblytsinonlyone
correctorientation.DONOTforcetheCPUand
heatsink assembly into the socket to prevent
damagingtheCPUpinsonthesocket.
TheheatsinkscrewsareT30models.Atorque
value of 12 inch-lbf is recommended.
2-10 Chapter 2: Hardware Information
2.4 System memory
2.4.1 Overview
Themotherboardcomeswithtwelve(12)DoubleDataRate4(DDR4)DualInlineMemory
Modules(DIMM)sockets.
ThegureillustratesthelocationoftheDDR4DIMMsockets:
2.4.2 Memory Configurations
Youmayinstall4GB,8GB,16GB,and32GBRDIMMsor32GBand64GBLR-DIMMsinto
theDIMMsocketsusingthememorycongurationsinthissection.
• RefertoASUSServerAVLfortheupdatedlistofcompatibleDIMMs.
• WheninstallingDIMMs,alwaysstartfromslotA1.
• AlwaysinstallDIMMswiththesameCASlatency.Foroptimumcompatibility,itis
recommended that you obtain memory modules from the same vendor.
Recommended Memory configuration
DIMM
A2 A1 B2 B1 C2 C1 D2 D1 E2 E1 F2 F1
1 DIMM -P----------
2 DIMMs -P-----P----
4 DIMMs -P-P---P-P- -
6 DIMMs -P-P-P-P-P-P
8 DIMMs P P -P-PPP -P-P
12 DIMMs P P PPPPPPPPPP
Youcanrefertothefollowingrecommendedmemorypopulation:
2-11
Z11PA-U12 Series
2.4.3 Installing a DIMM on a single clip DIMM socket
3. HoldtheDIMMatbothendsthen
inserttheDIMMintothesocket.
ApplyforcetobothendsoftheDIMM
simultaneously until the retaining clip
clicksintoplaceandtheDIMMis
seated securely in place.
1. Press the retaining clip outward to
unlocktheDIMMsocket.
2. AlignaDIMMonthesocketsuchthat
thenotchontheDIMMmatchesthe
DIMMslotkeyonthesocket.
Unlocked retaining clip
DIMM notch
DIMM slot key
1. Press the retaining clip outward to
unlocktheDIMM.
2. RemovetheDIMMfromthesocket.
Removing a DIMM from a single clip DIMM socket
• ToinstalltwoormoreDIMMs,refertotheuserguidebundledwiththemotherboard
package.
• Refertotheuserguideforqualiedvendorlistsofthememorymodules.
SupporttheDIMMlightlywithyourngerswhenpressingtheretainingclips.TheDIMM
mightgetdamagedwhenitipsoutwithextraforce.
AlwaysinserttheDIMMintothesocketVERTICALLYtopreventDIMMnotchdamage.
ADIMMiskeyedwithanotchsothatittsinonlyonedirection.DONOTforceaDIMMinto
asocketinthewrongdirectiontoavoiddamagingtheDIMM.
Locked Retaining Clip
2-12 Chapter 2: Hardware Information
2.5 Expansion slots
Inthefuture,youmayneedtoinstallexpansioncards.Thefollowingsubsectionsdescribethe
slots and the expansion cards that they support.
2.5.1 Installing an expansion card
Toinstallanexpansioncard:
1. Beforeinstallingtheexpansioncard,readthedocumentationthatcamewithitand
make the necessary hardware settings for the card.
2. Remove the system unit cover (if your motherboard is already installed in a chassis).
3. Removethebracketoppositetheslotthatyouintendtouse.Keepthescrewforlater
use.
4. Alignthecardconnectorwiththeslotandpressrmlyuntilthecardiscompletely
seated on the slot.
5. Secure the card to the chassis with the screw you removed earlier.
6. Replace the system cover.
2.5.2 Configuring an expansion card
Afterinstallingtheexpansioncard,congureitbyadjustingthesoftwaresettings.
1. TurnonthesystemandchangethenecessaryBIOSsettings,ifany.SeeChapter 4 for
informationonBIOSsetup.
2. Assign an IRQ to the card.
Refer to the table Standard Interrupt assignments in section Interrupt assignments for
more information.
3. Install the software drivers for the expansion card.
Ensure to unplug the power cord before adding or removing expansion cards. Failure to do
so may cause you physical injury and damage motherboard components.
WhenusingPCIecardsonsharedslots,ensurethatthedriverssupport“ShareIRQ”orthat
thecardsdonotneedIRQassignments.Otherwise,conictsmayarisebetweenthetwo
PCIegroups,makingthesystemunstableandthecardinoperable.
2-13
Z11PA-U12 Series
*TheseIRQsareusuallyavailableforISAorPCIdevices.
IRQ Priority Standard function
0 1 System Timer
1 2 KeyboardController
2 - Programmable Interrupt
3* 11 CommunicationsPort(COM2)
4* 12 CommunicationsPort(COM1)
5* 13 --
6 14 FloppyDiskController
7* 15 --
8 3 SystemCMOS/RealTimeClock
9* 4 ACPIModewhenused
10* 5 IRQHolderforPCISteering
11* 6 IRQHolderforPCISteering
12* 7 PS/2CompatibleMousePort
13 8 Numeric Data Processor
14* 9 PrimaryIDEChannel
15* 10 SecondaryIDEChannel
2.5.3 Interrupt assignments
Standard Interrupt assignments
2.5.4 PCI Express x16 slot (x16 link)
TheonboardPCIE4andPCIE2slotsprovidetwox16Gen3linktoCPU1andonlyPCIE4
supportsautoswitchestox8linkifPCIE3isoccupied.ThesetwoslotssupportVGAcards
and various server class high performance add-on cards.
2.5.5 PCI Express x8 slot (x8 link)
TheonboardPCIE3slotprovidesonex8Gen3linktoCPU1.ThisslotsupportsVGAcards
and various server class high performance add-on cards.
2.5.6 PCI Express x8 slot (x4 link)
TheonboardPCIE1slotprovidesonex4Gen3linktoCPU1Thisslotsupportsvariousserver
class high performance add-on cards.
2-14 Chapter 2: Hardware Information
No. (Slot location) Short description
1PCIE4
PCI-Ex16(x16Gen3Link)
(Auto switch to x8 Gen3 Link if slot 3 is occupied)
(support riser)
2PCIE3 PCI-Ex8(x8Gen3Link)
3PCIE2 PCI-Ex16(x16Gen3Link)
4PCIE1 PCI-Ex8(x4Gen3Link)
2-15
Z11PA-U12 Series
2. Baseboard Management Controller LED (BMCLED1)
ThegreenheartbeatLEDblinkspersecondtoindicatethattheASMB9isworking
normally.
2.6 Onboard LEDs
1. Standby Power LED (SBPWR1)
The motherboard comes with a standby power LED. The green LED lights up to
indicatethatthesystemisON,insleepmode,orinsoft-offmode.Thisisareminder
that you should shut down the system and unplug the power cable before removing or
plugging in any motherboard component. The illustration below shows the location of
the onboard LED.
2-16 Chapter 2: Hardware Information
3. CATT LED (CATERR1)
TheCATTLEDindicatesthatthesystemhasexperiencedafatalorcatastrophicerror
and cannot continue to operate.
4. Hard disk activity LED (HDDLED1)
ThisLEDisforthestoragedevicesconnectedtotheonboardSATA,orSATA/SAS
add-oncard.ThereadorwriteactivitiesofanydeviceconnectedtotheonboardSATA,
orSATA/SASadd-oncardcausestherearpanelLEDtolightup.
2-17
Z11PA-U12 Series
6. Location LED (LOCLED1)
This onboard LED lights up when the Location button on the server is pressed or when
triggered by a system management software. The Location LED helps visually locate
andquicklyidentifytheserverinerroronaserverrack.
5. Message LED (MESLED1)
ThisonboardLEDlightsuptoredwhenthereisaBMCeventlogisgenerated.
2-18 Chapter 2: Hardware Information
7. Q-Code LEDs (PORT80_LED1)
TheQ-CodeLEDprovidesa2-digitdisplaythatshowsthestatusofyoursystem.
• TheQ-CodeLEDsprovidethemostprobablecauseofanerrorcodeasastarting
point for troubleshooting. The actual cause may vary from case to case.
• PleaserefertotheQ-CodetableintheAppendix section for more details.
2-19
Z11PA-U12 Series
2.7 Jumpers
1. Clear RTC RAM (3-pin CLRTC1)
ThisjumperallowsyoutocleartheRealTimeClock(RTC)RAMinCMOS.Youcan
cleartheCMOSmemoryofdate,time,andsystemsetupparametersbyerasingthe
CMOSRTCRAMdata.TheonboardbuttoncellbatterypowerstheRAMdatainCMOS
which include system setup information such as system passwords.
ToerasetheRTCRAM:
1. Turn OFF the computer and unplug the power cord.
2. Movethejumpercapfromthedefaultpins1–2topins2–3.Keepthecaponpins
2–3forabout5to10seconds,thenmovethecapbacktopins1–2.
3. Plug the power cord and turn ON the computer.
4. Holddownthe<Del>keyduringthebootprocessandenterBIOSsetuptore-
enter data.
DONOTremovethecaponCLRTC1jumperdefaultpositionexcept when clearing the
RTCRAM. Removing the cap will cause system boot failure!
Ifthestepsabovedonothelp,removetheonboardbatteryandmovethejumperagainto
cleartheCMOSRTCRAMdata.AftertheCMOSclearance,reinstallthebattery.
2-20 Chapter 2: Hardware Information
2. VGA controller setting (3-pin VGA_SW1)
ThisjumperallowsyoutoenableordisabletheonboardVGAcontroller.Settopins1–2
to activate the VGA feature.
3. LAN controller setting (3-pin LAN_SW1, LAN_SW2)
ThesejumpersallowyoutoenableordisabletheonboardLAN_SW1orLAN_SW2.
Set to pins 1–2 to activate the Gigabit LAN feature.
2-21
Z11PA-U12 Series
4. ME firmware force recovery setting (3-pin ME_RCVR1)
This jumper allows you to force Intel®ManagementEngine(ME)bootfromrecovery
modewhenMEbecomescorrupted.
5. DDR4 thermal event setting (3-pin DIMMTRIP1)
ThisjumperallowsyoutoenableordisableDDR4DIMMthermalsensingeventpin.
2-22 Chapter 2: Hardware Information
6. PCH_MFG1 setting (3-pin PCH_MFG1)
ThisjumperallowsyoutoupdatetheBIOSMEblock.
7. Smart Ride Through (SmaRT) setting (3-pin SMART_PSU1)
This jumper allows you to enable or disable the Smart Ride Through (SmaRT) function.
Thisfeatureisdisabledbydefault.Settopins1-2toenableit.Whenenabled,SmaRT
allowsuninterruptedoperationofthesystemduringanAClossevent.
2-23
Z11PA-U12 Series
8. DMLAN setting (3-pin DM_IP_SEL1)
ThisjumperallowsyoutoselecttheDMLANsetting.Settopins2-3toforcethe
DMLANIPtostaticmode(IP=10.10.10.10,submask=255.255.255.0).
9. IPMI SW setting (3-pin IPMI_SW1)
ThisjumperallowsyoutoselectwhichprotocolintheGPUsensortofunction.
2-24 Chapter 2: Hardware Information
10. Baseboard Management Controller setting (3-pin BMC_EN1)
Thisjumperallowsyoutoenable(default)ordisableon-boardBMC.Ensuretosetthis
BMCjumpertoenabledtoavoidsystemfancontrolandhardwaremonitorerror.
2-25
Z11PA-U12 Series
2.8 Connectors
2.8.1 Rear panel connectors
1. Video Graphics Adapter (VGA) port: This port is for a VGA monitor or other VGA-
compatible devices..
2. SFP+ LEDs (only available for Z11PA U12/10G-2S): These LEDs indicate the link
status and the link speed of the SFP+ ports. Refer to the table below for the SFP+ LED
indications.
3. Power-on Button: Press this button to turn on the system.
4. RJ-45 port for iKVM:ThisRJ-45portfunctionswhenyouenabletheASMB8
controller.
5. RJ-45 ports for LAN 1 and 2: These ports allow Gigabit connection to a LAN through
a network hub. Refer to the LAN port LED indications table for more information.
6. SFP+ ports (only available for Z11PA U12/10G-2S): These ports are for connecting
the enhanced small form-factor pluggable (SFP+) module that supports data rates up
to 10 Gbps.
7. USB 3.0 ports 1 and 2: Thesetwo4-pinUniversalSerialBus(USB)portsareavailable
forconnectingUSB3.0devices.
2-26 Chapter 2: Hardware Information
SPEED
LED
ACT/LINK
LED
Activity/Link LED Speed LED
Status Description Status Description
OFF No link OFF 10Mbpsconnection
ORANGE Linked ORANGE 100Mbpsconnection
BLINKING Data activity GREEN 1 Gbps connection
Activity/Link LED Speed LED
Status Description Status Description
OFF No link OFF 10Mbpsconnection
GREEN Linked ORANGE 100Mbpsconnection
BLINKING Data activity GREEN 1 Gbps connection
Management LAN port LED indications
SFP+_LED indications (only available for Z11PA U12/10G-2S)
Activity LED Speed LED
Status Description Status Description
OFF No activity OFF -
BLINKING Data activity AMBER 1 Gbps connection
GREEN 10 Gbps connection
SFP+ LED
Speed LED
Activity LED
LAN1/LAN2 LEDs
ACT/LINK
LED SPEED
LED
2-27
Z11PA-U12 Series
2.8.2 Internal connectors
1. Serial ATA connectors (7-pin SSATA1)
Thisconnector,controlledbyIntel®C620chipset,isfortheSerialATAsignalcablefor
Serial ATA hard disk drives.
2. Mini-SAS HD connector (ISATA1-2; ISSATA1)
ThismotherboardcomeswithminiSerialAttachedSCSI(SAS)HDconnectors,the
storage technology that supports Serial ATA. Each connector supports up to four
devices.
2-28 Chapter 2: Hardware Information
3. M.2 (NGFF) connector (NGFF1)
ThisconnectorallowsyoutoinstallanM.2device.
Thisconnectorsupportstype2242/2260/2280devicesonbothPCI-E(2lanesonly)and
SATA interface.
TheM.2(NGFF)deviceispurchasedseparately.
4. Trusted Platform Module connector (14-1 pin TPM1)
ThisconnectorsupportsaTrustedPlatformModule(TPM)system,whichcansecurely
storekeys,digitalcerticates,passwords,anddata.ATPMsystemalsohelpsenhance
networksecurity,protectsdigitalidentities,andensuresplatformintegrity.
2-29
Z11PA-U12 Series
5. USB 2.0 connector (10-1 pin USB56)
ThisconnectorisforUSB2.0ports.ConnecttheUSBmodulecabletotheconnector,
and then install the module to a slot opening at the back of the system chassis. The
USBconnectorscomplywithUSB2.0specicationthatsupportsupto480Mbps
connection speed.
6. USB 3.0 connector (20-1 pin USB3_34)
ThisconnectorallowsyoutoconnectaUSB3.0moduleforadditionalUSB3.0front
orrearpanelports.WithaninstalledUSB3.0module,youcanenjoyallthebenetsof
USB3.0includingfasterdatatransferspeedsofupto5Gbps,fasterchargingtimefor
USB-chargeabledevices,optimizedpowerefciency,andbackwardcompatibilitywith
USB2.0.
TheUSBportmoduleispurchasedseparately.
TheUSBportmoduleispurchasedseparately.
2-30 Chapter 2: Hardware Information
7. Power Supply SMBus connector (5-pin PSUSMB1)
ThisconnectorallowsyoutoconnectSMBus(SystemManagementBus)tothePSU
(powersupplyunit)toreadPSUinformation.DevicescommunicatewithanSMBus
hostand/orotherSMBusdevicesusingtheSMBusinterface.
PowersupplyisrequiredtomeetPMBusspecicationandcustomizedBMCFWmaybe
needed.PleasecontactASUSifyourneedfurthersupport.
8. Serial port connector (10-1 pin COM1)
ThisconnectorisfortheserialCOMport.Connecttheserialportmodulecabletoone
oftheseconnectors,theninstallthemoduletoaslotopeningatthebackofthesystem
chassis.
TheCOMmoduleispurchasedseparately.
2-31
Z11PA-U12 Series
9. CPU, front, and rear fan connectors (4-pin CPU_FAN1, FRNT_FAN1-4,
REAR_FAN1)
Thefanconnectorssupportcoolingfans.Connectthefancablestothefanconnectors
onthemotherboard,ensuringthattheblackwireofeachcablematchesthegroundpin
of the connector.
• DONOTforgettoconnectthefancablestothefanconnectors.Insufcientairow
inside the system may damage the motherboard components.
• Thesearenotjumpers!DONOTplacejumpercapsonthefanconnectors!
• AllfansfeaturetheASUSSmartFantechnology.
10. Hard disk activity LED connector (4-pin HDLED1)
This LED connector is for the storage add-on card cable connected to the SATA or
SAS add-on card. The read or write activities of any device connected to the SATA or
SAS add-on card causes the front panel LED to light up.
2-32 Chapter 2: Hardware Information
11. EATX power connectors (24-pin EATXPWR, 8-pin EATX12V1)
These connectors are for the SSI or ATX power supply plugs. The power supply plugs
aredesignedtottheseconnectorsinonlyoneorientation.Findtheproperorientation
andpushdownrmlyuntiltheconnectorscompletelyt.
• DONOTforgettoconnectthe24+8-pinpowerplugswhenusing85WorbelowCPU;
otherwise,thesystemwillnotbootup.
• UseofaPSUwithahigherpoweroutputisrecommendedwhenconguringasystem
with more power-consuming devices. The system may become unstable or may not
bootupifthepowerisinadequate.
• Ensurethatyourpowersupplyunit(PSU)canprovideatleasttheminimumpower
requiredbyyoursystem.
12. LAN34_LED connector (5-1 pin LAN34_LED1)
TheseLEDsareforGigabitLANactivityLEDsonthefrontpanel.ConnecttheLAN
LED cable to the backplane for LAN activity indication.
2-33
Z11PA-U12 Series
13. System panel connector (20-1 pin PANEL1)
This connector supports several chassis-mounted functions.
1. System power LED (3-pin PLED)
This3-pinconnectorisforthesystempowerLED.Connectthechassispower
LED cable to this connector. The system power LED lights up when you turn on
thesystempower,andblinkswhenthesystemisinsleepmode.
2. Message LED (2-pin MLED)
This 2-pin connector is for the message LED cable that connects to the front
messageLED.ThemessageLEDiscontrolledbyHardwaremonitortoindicate
an abnormal event occurance.
3. System warning speaker (4-pin SPEAKER)
This 4-pin connector is for the chassis-mounted system warning speaker. The
speaker allows you to hear system beeps and warnings.
4. Hard disk drive activity LED (2-pin HDD LED)
This2-pinconnectorisfortheHDDActivityLED.ConnecttheHDDActivityLED
cabletothisconnector.TheHDLEDlightsuporasheswhendataisreadfrom
orwrittentotheHDD.
5. Power button/soft-off button (2-pin PWRSW)
This connector is for the system power button. Pressing the power button turns
thesystemonorputsthesysteminsleeporsoft-offmodedependingontheBIOS
settings. Pressing the power switch for more than four seconds while the system
is ON turns the system OFF.
6. Reset button (2-pin RESET)
This 2-pin connector is for the chassis-mounted reset button for system reboot
without turning off the system power.
2-34 Chapter 2: Hardware Information
14. Auxiliary panel connector (20-2 pin AUX_PANEL1)
ThisconnectorisforadditionalfrontpanelfeaturesincludingfrontpanelSMB,locator
LEDandswitch,andLANLEDs.
1. Front panel SMB (10-2 pin FPSMB)
TheseconnectorsareforthefrontpanelSMBuscable.
2. LAN activity LED (2-pin LAN1_LED, LAN2_LED)
These connectors are for Gigabit LAN activity LEDs on the front panel.
3. Locator LED (2-pin LOCATORLED1, LOCATORLED2)
TheseconnectorsareforthelocatorLED1andLED2onthefrontpanel.Connect
the Locator LED cables to these 2-pin connector. The LEDs will light up when the
Locator button is pressed.
4. Locator Button/Switch (2-pin LOCATORBTN)
Theseconnectorsareforthelocatorbuttononthefrontpanel.Thisbuttonqueries
the state of the system locator.
2-35
Z11PA-U12 Series
16. Chassis Intrusion (2-pin INTRUSION1)
These leads are for the intrusion detection feature for chassis with intrusion sensor or
microswitch.Whenyouremoveanychassiscomponent,thesensortriggersandsends
a high level signal to these leads to record a chassis intrusion event. The default setting
isshortCHASSIS#andGNDpinbyjumpercaptodisablethefunction.
15. VPP_I2C1 connector (10-1 pin VPP_I2C1)
ThisconnectorisusedfortheIntelVMDfunctionandsensorreadings.
2-36 Chapter 2: Hardware Information
17. OCUPCIE connectors (OCUPCIE1-2)
ConnectsthePCIEsignaltothefrontrisercardorNVMEportonthebackplane.
18. System Management Bus (SMBUS) connectors (5-1 pin SMBUS1; 6-1 pin SMBUS2)
These connectors control the system and power management-related tasks. These
connectors process the messages to and from devices rather than tripping the individual
control lines.
2-37
Z11PA-U12 Series
19. Serial General Purpose Input/Output connector (6-1 pin SSGPIO1)
The SSGPIO 1 connector is used for the Intel Rapid Storage Technology Enterprise
SGPIOinterfacethatcontrolstheLEDpatterngeneration,deviceinformation,and
general purpose data.
20. VGA connector (16-pin VGA_HDR1)
ThisconnectorsupportstheVGAHighDynamic-Rangeinterface.
2-38 Chapter 2: Hardware Information
21. VROC_KEY connector (4-pin VROC_KEY1)
ThisconnectorallowsyoutoconnectaKEYmoduletosupportIntelVMDRAID
function.
22. Thermal sensor cable connector (3-pin TR1)
This connector allows you to connect a Thermal sensor cable that is used for
temperaturemonitoring.ConnecttheThermalsensorcabletotheconnectorandplace
its probe to the device that you want to check the temperature.
3
Powering Up
This chapter describes the power up sequence, and ways of
shutting down the system.
Chapter 3: Powering Up
3-2 Chapter 3: Powering Up
3.1 Starting up for the first time
1. After making all the connections, replace the system case cover.
2. Be sure that all switches are off.
3. Connect the power cord to the power connector at the back of the system chassis.
4. Connect the power cord to a power outlet that is equipped with a surge protector.
5. Turn on the devices in the following order:
a. Monitor
b. External storage devices (starting with the last device on the chain)
c. System power
6. After applying power, the system power LED on the system front panel case lights up.
For systems with ATX power supplies, the system LED lights up when you press the
ATX power button. If your monitor complies with “green” standards or if it has a “power
standby” feature, the monitor LED may light up or switch between orange and green
after the system LED turns on.
The system then runs the power-on self-test or POST. While the tests are running, the
BIOS beeps or additional messages appear on the screen. If you do not see anything
within 30 seconds from the time you turned on the power, the system may have failed
a power-on test. Check the jumper settings and connections or call your retailer for
assistance.
The following shows the possible beep codes and its corresponding error condition
BIOS Beep codes
Beep Error condition
1 short Power supply surges detected during the previous power on.
1 short No Keyboard Detected.
1 short, 2 short No DIMM Detected.
1 short, 8 short No VGA Detected.
2 long Chassis Intrusion.
2 long BIOS-image Crash Detected.
7. At power on, hold down the <Del> key to enter the BIOS Setup. Follow the instructions
in Chapter 4.
3-3
Z11PA-U12 Series
3.2 Powering off the computer
3.2.1 Using the OS shut down function
Using Windows® Server 2012 R2:
1. Press <Ctrl>+<Alt>+<Del>.
2. Click on the Power icon on the lower right side of the screen.
3. Select
Shut down.
4. In the Shutdown Event Tracker, select the Other (Planned) option in the selection
lists. Otherwise, select the option that best describes why you want to shut down the
computer.
5. Click
Continue.
Using Windows® Server 2016:
1. Press <Alt>+<F4>.
2. In the What do you want the computer to do?, select Shut down.
3. In the Shutdown Event Tracker, select the Other (Planned) option in the selection
list. Otherwise, select the option that best describes why you want to shut down the
computer.
4. Click
OK.
3.2.2 Using the dual function power switch
While the system is ON, press the power switch for less than four seconds to put the system
to sleep mode or to soft-off mode, depending on the BIOS setting.
Pressing the power switch for more than four seconds lets the system enter the soft-off
mode regardless of the BIOS setting.
3-4 Chapter 3: Powering Up
4
BIOS Setup
This chapter tells how to change the system settings through
the BIOS Setup menus. Detailed descriptions of the BIOS
parameters are also provided.
Chapter 4: BIOS Setup
4-2 Chapter 4: BIOS Setup
4.1 Managing and updating your BIOS
The following utilities allow you to manage and update the motherboard Basic Input/Output
System (BIOS) setup:
1. ASUS CrashFree BIOS 3
TorecovertheBIOSusingabootableUSBashdiskdrivewhentheBIOSlefailsor
gets corrupted.
2. ASUS EzFlash
UpdatestheBIOSusingaUSBashdisk.
3. BUPDATER
UpdatestheBIOSinDOSmodeusingabootableUSBashdiskdrive.
Refer to the corresponding sections for details on these utilities.
4.1.1 ASUS CrashFree BIOS 3 utility
TheASUSCrashFreeBIOS3isanautorecoverytoolthatallowsyoutorestoretheBIOSle
when it fails or gets corrupted during the updating process. You can update a corrupted BIOS
leusingaUSBashdrivethatcontainstheupdatedBIOSle.
PrepareaUSBashdrivecontainingtheupdatedmotherboardBIOSbeforeusingthis
utility.
Recovering the BIOS from a USB flash drive
TorecovertheBIOSfromaUSBashdrive:
1. InserttheUSBashdrivewiththeoriginalorupdatedBIOSletooneUSBportonthe
system.
2. The utility will automatically recover the BIOS. It resets the system when the BIOS
recoverynished.
DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause
system boot failure!
The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the
ASUSwebsiteatwww.asus.comtodownloadthelatestBIOSle.
SaveacopyoftheoriginalmotherboardBIOSletoabootableUSBashdiskdrivein
case you need to restore the BIOS in the future. Copy the original motherboard BIOS using
the BUPDATER utility.
4-3
Z11PA-U12 Series
3. Press <Tab> to switch to the Driveeld.
4. PresstheUp/DownarrowkeystondtheUSBashdiskthatcontainsthelatestBIOS
then press <Enter>.
5. Press <Tab> to switch to the Folder Info eld.
6. PresstheUp/DownarrowkeystondtheBIOSlethenpress<Enter>.
7. Reboot the system when the update process is done.
4.1.2 ASUS EzFlash Utility
TheASUSEzFlashUtilityfeatureallowsyoutoupdatetheBIOSusingaUSBashdisk
without having to use a DOS-based utility.
The succeeding BIOS screens are for reference only. The actual BIOS screen displays
may not be the same as shown.
To update the BIOS using EzFlash Utility:
1. InserttheUSBashdiskthatcontainsthelatestBIOSletotheUSBport.
2. Enter the BIOS setup program. Go to the Tool menu to select Start EzFlash and press
<Enter> to enable it.
Download the latest BIOS from the ASUS website at www.asus.com before using this
utility.
ASUS Tek. EzFlash Utility
[Up/Down/Left/Right]:Switch [Enter]:Choose [q]:Exit
FS0 System Volume Information <DIR>
Windows <DIR>
Z11PA-U12-ASUS-0204 <DIR>
Current Platform
Platform : Z11PA-U12 Platform : Z11PA-U12
Version : 0106
Build Date :06/21/2017
New Platform
Version : 0204
Build Date :07/24/2017
4-4 Chapter 4: BIOS Setup
• ThisfunctioncansupportdevicessuchasaUSBashdiskwithFAT32/16formatand
single partition only.
• DONOTshutdownorresetthesystemwhileupdatingtheBIOStopreventsystem
boot failure!
4.1.3 BUPDATER utility
The succeeding BIOS screens are for reference only. The actual BIOS screen displays
may not be the same as shown.
TheBUPDATERutilityallowsyoutoupdatetheBIOSleinDOSenvironmentusinga
bootableUSBashdiskdrivewiththeupdatedBIOSle.
Updating the BIOS file
ToupdatetheBIOSleusingtheBUPDATERutility:
1. VisittheASUSwebsiteatwww.asus.comanddownloadthelatestBIOSleforthe
motherboard.SavetheBIOSletoabootableUSBashdiskdrive.
2. Download the BUPDATER utility (BUPDATER.exe) from the ASUS support website at
support.asus.comtothebootableUSBashdiskdriveyoucreatedearlier.
3. Boot the system in DOS mode, then at the prompt, type:
BUPDATER/i[lename].CAP
where[lename]isthelatestortheoriginalBIOSleonthebootableUSBashdisk
drive, then press <Enter>.
A:\>BUPDATER /i[le name]CAP
Ensure to load the BIOS default settings to ensure system compatibility and stability. Press
<F5> and select Yes to load the BIOS default settings.
4-5
Z11PA-U12 Series
4. Theutilityveriesthele,thenstartsupdatingtheBIOSle.
DO NOT shut down or reset the system while updating the BIOS to prevent system boot
failure!
5. The utility returns to the DOS prompt after the BIOS update process is completed.
Rebootthesystemfromtheharddiskdrive.
The BIOS update is nished! Please restart your system.
C:\>
Current Platform
Platform : Z11PA-U12
Version : 0106
Build date: 06/21/2017
New Platform
Platform : Z11PA-U12
Version : 0204
Build date: 07/24/2017
ASUS Tek. EzFlash Utility
Start Programming Flash. DO NOT SHUTDOWN THE SYSTEM!!!
Write
75%
4-6 Chapter 4: BIOS Setup
4.2 BIOS setup program
Thismotherboardsupportsaprogrammablermwarechipthatyoucanupdateusingthe
provided utility described in section 4.1 Managing and updating your BIOS.
UsetheBIOSSetupprogramwhenyouareinstallingamotherboard,reconguringyour
system,orpromptedto“RunSetup.”Thissectionexplainshowtocongureyoursystem
using this utility.
EvenifyouarenotpromptedtousetheSetupprogram,youcanchangethecongurationof
your computer in the future. For example, you can enable the security password feature or
changethepowermanagementsettings.Thisrequiresyoutorecongureyoursystemusing
the BIOS Setup program so that the computer can recognize these changes and record them
intheCMOSRAMofthermwarechip.
ThermwarechiponthemotherboardstorestheSetuputility.Whenyoustartupthe
computer, the system provides you with the opportunity to run this program. Press <Del>
during the Power-On Self-Test (POST) to enter the Setup utility; otherwise, POST continues
with its test routines.
If you wish to enter Setup after POST, restart the system by pressing <Ctrl+Alt+Delete>, or by
pressing the reset button on the system chassis. You can also restart by turning the system
offandthenbackon.Dothislastoptiononlyifthersttwofailed.
TheSetupprogramisdesignedtomakeitaseasytouseaspossible.Beingamenu-driven
program,itletsyouscrollthroughthevarioussub-menusandmakeyourselectionsfromthe
availableoptionsusingthenavigationkeys.
• ThedefaultBIOSsettingsforthismotherboardapplyformostconditionstoensure
optimum performance. If the system becomes unstable after changing any BIOS
settings, load the default settings to ensure system compatibility and stability. Press
<F5> and select Yes to load the BIOS default settings.
• TheBIOSsetupscreensshowninthissectionareforreferencepurposesonly,and
may not exactly match what you see on your screen.
• VisittheASUSwebsite(www.asus.com)todownloadthelatestBIOSleforthis
motherboard.
4-7
Z11PA-U12 Series
4.2.1 BIOS menu screen
Navigation keys
General helpMenu bar Configuration fieldsMenu items
4.2.2 Menu bar
The menu bar on top of the screen has the following main items:
Main Forchangingthebasicsystemconguration
Ai Tweaker Forchangingtheoverclockingsettings
Advanced For changing the advanced system settings
Platform Configuration For changing the platform settings
Socket Configuration Forchangingthesocketsettings
Event Logs For changing the event log settings
Server Mgmt For changing the server mgmt settings
Security For changing the security settings
Boot Forchangingthesystembootconguration
Tool Forconguringoptionsforspecialfunctions
Save & Exit For selecting the save & exit options
Toselectanitemonthemenubar,presstherightorleftarrowkeyonthekeyboarduntilthe
desired item is highlighted.
4-8 Chapter 4: BIOS Setup
4.2.3 Menu items
Thehighlighteditemonthemenubardisplaysthespecicitemsforthatmenu.Forexample,
selecting Main shows the Main menu items.
Theotheritems(Advanced,PlatformConguration,SocketConguration,EventLogs,Server
Mgmt, Security, Boot, Tool, and Save & Exit) on the menu bar have their respective menu
items.
4.2.4 Submenu items
A solid triangle before each item on any menu screen means that the item has a submenu.
To display the submenu, select the item then press <Enter>.
4.2.5 Navigation keys
AtthebottomrightcornerofamenuscreenarethenavigationkeysfortheBIOSsetup
program.Usethenavigationkeystoselectitemsinthemenuandchangethesettings.
4.2.6 General help
At the top right corner of the menu screen is a brief description of the selected item.
4.2.7 Configuration fields
Theseeldsshowthevaluesforthemenuitems.Ifanitemisuser-congurable,youcan
changethevalueoftheeldoppositetheitem.Youcannotselectanitemthatisnotuser-
congurable.
Acongurableeldisenclosedinbrackets,andishighlightedwhenselected.Tochangethe
valueofaeld,selectitandpress<Enter>todisplayalistofoptions.
4.2.8 Pop-up window
Selectamenuitemandpress<Enter>todisplayapop-upwindowwiththeconguration
options for that item.
4.2.9 Scroll bar
Ascrollbarappearsontherightsideofamenuscreenwhenthereareitemsthatdonotton
thescreen.PresstheUp/Downarrowkeysor<PageUp>/<PageDown>keystodisplaythe
other items on the screen.
4-9
Z11PA-U12 Series
4.3 Main menu
WhenyouentertheBIOSSetupprogram,theMainmenuscreenappears.TheMainmenu
provides you an overview of the basic system information, and allows you to set the system
date, time, language, and security settings.
4.3.1 System Date [Day xx/xx/xxxx]
Allows you to set the system date.
4.3.2 System Time [xx:xx:xx]
Allows you to set the system time.
4-10 Chapter 4: BIOS Setup
4.4 Advanced menu
The Advanced menu items allow you to change the settings for the CPU and other system
devices.
TakecautionwhenchangingthesettingsoftheAdvancedmenuitems.Incorrecteld
values can cause the system to malfunction.
4.4.1 Trusted Computing
Configuration
Security Device Support [Enabled]
Allows you to enable or disable the BIOS support for security device.
Congurationoptions:[Disabled][Enabled]
4-11
Z11PA-U12 Series
4.4.3 Smart Settings
SMART Self Test [Enabled]
Allows you to run SMART Self Test on all HDDs during POST.
Congurationoptions:[Disabled][Enabled]
4.4.2 ACPI Settings
Enable ACPI Auto Configuration [Disabled]
AllowsyoutoenableordisabletheBIOSACPIAutoConguration.
Congurationoptions:[Disabled][Enabled]
Enable Hibernation [Enabled]
Allows you to enable or disable the ability of the system to hibernate (OS/S4 Sleep State).
Congurationoptions:[Disabled][Enabled]
This option may be not be effective with some OS.
4-12 Chapter 4: BIOS Setup
4.4.4 Super IO Configuration
Serial Port 1 Configuration
Allows you to set the parameters of Serial Port 1.
Serial Port [Enabled]
Allows you to enable or disable Serial Port.
Congurationoptions:[Disabled][Enabled]
The following item appears only when you set Serial Port to [Enabled].
Change Settings [Auto]
Allows you to choose the setting for Super IO device.
Congurationoptions:[Auto][IO=3F8h;IRQ=4;][IO=3F8h;IRQ=3,4,5,6,7,9,10,11,
12;][IO=2F8h;IRQ=3,4,5,6,7,9,10,11,12;][IO=3E8h;IRQ=3,4,5,6,7,9,10,11,
12;][IO=2E8h;IRQ=3,4,5,6,7,9,10,11,12;]
4.4.5 Serial Port Console Redirection
COM1 / COM2
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Congurationoptions:[Disabled][Enabled]
4-13
Z11PA-U12 Series
Console Redirection Settings
ThisitembecomescongurableonlywhenyouenabletheConsole Redirection item. The
settings specify how the host computer and the remote computer (which the user is using)
will exchange data. Both computers should have the same or compatible settings.
The following item appears only when you set Console Redirection to [Enabled].
Terminal Type [VT-UTF8]
Allows you to set the terminal type.
[VT100] ASCIIcharset.
[VT100+] ExtendsVT100tosupportcolor,functionkeys,etc.
[VT-UTF8] UsesUTF8encodingtomapUnicodecharsonto1ormorebytes.
[ANSI] ExtendedASCIIcharset.
Bits per second [57600]
Selects serial port transmission speed. The speed must be matched on the other side.
Longornoisylinesmayrequirelowerspeeds.
Congurationoptions:[9600][19200][38400][57600][115200]
Data Bits [8]
Congurationoptions:[7][8]
Parity [None]
Aparitybitcanbesentwiththedatabitstodetectsometransmissionerrors.[Mark]
and[Space]paritydonotallowforerrordetection.
[None] None.
[Even] paritybitis0ifthenumof1’sinthedatabitsiseven.
[Odd] paritybitis0ifnumof1’sinthedatabitsisodd.
[Mark] paritybitisalways1.
[Space] paritybitisalways0.
Stop Bits [1]
Stopbitsindicatetheendofaserialdatapacket.(Astartbitindicatesthebeginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit.
Congurationoptions:[1][2]
4-14 Chapter 4: BIOS Setup
Flow Control [Hardware RTS/CTS]
Flowcontrolcanpreventdatalossfrombufferoverow.Whensendingdata,ifthe
receivingbuffersarefull,a“stop”signalcanbesenttostopthedataow.Oncethe
buffersareempty,a“start”signalcanbesenttore-starttheow.Hardwareow
control uses two wires to send start/stop signals.
Congurationoptions:[None][HardwareRTS/CTS]
VT-UTF8 Combo Key Support [Enabled]
Allows you to enable the VT-UTF8 Combo Key Support for ANSI/VT100 terminals.
Congurationoptions:[Disabled][Enabled]
Recorder Mode [Disabled]
Withthismodeenabledonlytextwillbesent.ThisistocaptureTerminaldata.
Congurationoptions:[Disabled][Enabled]
Legacy OS Redirection Resolution [80x24]
ThisallowsyoutosetthenumberofrowsandcolumnssupportedontheLegacyOS.
Congurationoptions:[80x24][80x25]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty.
Congurationoptions:[VT100][LINUX][XTERMR6][SCO][ESCN][VT400]
Redirection After BIOS POST [Always Enable]
ThissettingallowsyoutospecifyifBootloaderisselectedthanLegacyconsole
redirection.
Congurationoptions:[AlwaysEnable][Bootloader]
Legacy Console Redirection Settings
Legacy Serial Redirection Port [COM1]
AllowsyoutoselectaCOMporttodisplayredirectionofLegacyOSandLegacy
OPROM Messages.
Congurationoptions:[COM1][COM2]
Serial Port for Out-of-Band Management/
Windows Emergency Management Services (EMS)
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Congurationoptions:[Disabled][Enabled]
4-15
Z11PA-U12 Series
The following item appears only when you set Console Redirection to [Enabled].
Console Redirection Settings
Out-of-Band Mgmt Port [COM1]
MicrosoftWindowsEmergencyManagementServices(EMS)allowsforremote
managementofaWindowsServerOSthroughaserialport.
Congurationoptions:[COM1][COM2]
Terminal Type [VT-UTF8]
Allows you to set the terminal type for out-of-band management.
Congurationoptions:[VT100][VT100+][VT-UTF8][ANSI]
Bits per second [115200]
Allows you to set the serial port transmission speed.
Congurationoptions:[9600][19200][57600][115200]
Flow Control [None]
Allowsyoutosettheowcontroltopreventdatalossfrombufferoverow.
Congurationoptions:[None][HardwareRTS/CTS][SoftwareXon/Xoff]
4.4.6 Onboard LAN
Onboard I210 LAN Configuration
4-16 Chapter 4: BIOS Setup
Onboard X722 LAN Configuration
Intel LAN1 Enable [Enabled]
AllowsyoutoenableordisabletheIntelLAN.
Congurationoptions:[Disabled][Enabled]
The following item appears only when you set Intel LAN1 Enable to [Enabled].
Intel LAN ROM Type [PXE]
AllowsyoutoselecttheIntelLANROMtype.
Congurationoptions:[Disabled][PXE][iSCSI]
Due to Intel®limitations,bothIntelLANROMTypeoptionsshouldbethesamewhen[PXE]
or [iSCSI] is selected.
Intel LAN2 Enable [Enabled]
AllowsyoutoenableordisabletheIntelLAN.
Congurationoptions:[Disabled][Enabled]
The following item appears only when you set Intel LAN2 Enable to [Enabled].
Intel LAN ROM Type [Disabled]
AllowsyoutoselecttheIntelLANROMtype.
Congurationoptions:[Disabled][PXE][iSCSI]
Due to Intel®limitations,bothIntelLANROMTypeoptionsshouldbethesamewhen[PXE]
or [iSCSI] is selected.
Intel X722 LAN Enable [Enabled]
AllowsyoutoenableordisabletheIntelLAN.
Congurationoptions:[Disabled][Enabled]
4-17
Z11PA-U12 Series
4.4.7 APM
AllowsyoutoconguretheAdvancePowerManagement(APM)settings.
Restore AC Power Loss [Last State]
Whensetto[PowerOff],thesystemgoesintooffstateafteranACpowerloss.Whenset
to[PowerOn],thesystemwillrebootafteranACpowerloss.Whensetto[LastState],the
system goes into either off or on state, whatever the system state was before the AC power
loss.
Congurationoptions:[PowerOff][PowerOn][LastState]
Power On By PCIE [Disabled]
[Disabled] DisablesthePCIEdevicestogenerateawakeevent.
[Enabled] EnablesthePCIEdevicestogenerateawakeevent.
Power On By RTC [Disabled]
[Disabled] DisablesRTCtogenerateawakeevent.
[Enabled] Whensetto[Enabled],theitemsRTC Alarm Date (Days) and
Hour/Minute/Secondwillbecomeuser-congurablewithsetvalues.
4-18 Chapter 4: BIOS Setup
Load RT32 Image [Disabled]
AllowsyoutoenableordisableRT32ImageLoading.
Congurationoptions:[Disabled][Enabled]
Above 4G Decoding [Disabled]
Allows you to enable or disable 64-bit capable devices to be decoded in above 4G address
space.Itonlyworksifthesystemsupports64-bitPCIdecoding.
Congurationoptions:[Disabled][Enabled]
SR-IOV Support [Enabled]
This option enables or disables SIngle Root IO Virtualization Support if the system has
SRIOV capable PCIe devices.
Congurationoptions:[Disabled][Enabled]
PCI Express Settings
PCI Express Device Register Settings
Relaxed Ordering [Enabled]
This option allows you to enable or disable PCI Express Device Relaxed Ordering.
Congurationoptions:[Disabled][Enabled]
Extended Tag [Disabled]
ThisoptionallowsDevicetousean8-bitTageldasarequesterwhensettoEnabled.
Congurationoptions:[Disabled][Enabled]
No Snoop [Enabled]
This option allows you to enable or disable PCI Express Device No Snoop option.
Congurationoptions:[Disabled][Enabled]
Maximum Payload [Auto]
This option allows you to set the Maximum Payload of PCI Express Device or allow
System BIOS to select the value.
Congurationoptions:[Auto][128Bytes][256Bytes][512Bytes][1024Bytes]
[2048Bytes][4096Bytes]
4.4.8 PCI Subsystem Settings
AllowsyoutocongurePCI,PCI-X,andPCIExpressSettings.
4-19
Z11PA-U12 Series
Maximum Read Request [Auto]
This option allows you to set the Maximum Read Request of PCI Express Device or
allow System BIOS to select the value.
Congurationoptions:[Auto][128Bytes][256Bytes][512Bytes][1024Bytes]
[2048Bytes][4096Bytes]
PCI Express Device Link Register Settings
ASPM Support [Disabled]
This option allows you to set the ASPM level.
[ForceL0s] ForcealllinkstoL0sState.
[Auto] BIOSautocongure.
[Disabled] DisablesASPM.
Enabling ASPM may cause some PCI-E devices to fail.
Extended Synch [Disabled]
This option allows the generation of Extended Synchronization patterns when set to
Enabled.
Congurationoptions:[Disabled][Enabled]
Link Training Retry [5]
ThisoptionallowsyoutosetthenumberofRetryAttemptssoftwarewilltaketoretrain
thelinkifprevioustrainingattemptwasunsuccessful.
Congurationoptions:[Disabled][2][3][5]
Link Training Timeout [1000]
This option allows you to set the number of Microseconds software will wait before
polling‘LinkTraining’butinLinkStatusRegister.Thevaluerangesfrom10to10000
uS.
Unpopulated Links [Keep Link On]
ThisoptionwilldisableunpopulatedPCIExpresslinkstosavepowerwhensetto
Disabled.
Congurationoptions:[Disabled][KeepLinkOn]
PCI Express Gen 2 Settings
PCI Express GEN2 Device Register Settings
Completion Timeout [Default]
This option allows system software to modify the Completion Timeout value for device
Functions which support Completion Timeout programmability.
[Default] 50usto50ms.
[Shorter] Shortertimeoutrangessupportedbyhardwarewillbeused.
[Longer] Longertimeoutrangessupportedbyhardwarewillbeused.
[Disabled] DisableCompletionTimeout.
4-20 Chapter 4: BIOS Setup
ARI Forwarding [Disabled]
If supported by hardware and set to Enabled, the Downstream Port disables
itstraditionalDeviceNumberledbeing0enforcementwhenturningaType1
CongurationRequestintoaType0CongurationRequest,permittingaccessto
Extended Functions in an ARI Device immediately below the Port.
Congurationoptions:[Disabled][Enabled]
Atomic0p Request Enable [Disabled]
If supported by hardware and set to Enabled, this function initiates Atomic0p Requests
only if Bus Master Enable bit is in the Command Register Set.
Congurationoptions:[Disabled][Enabled]
Atomic0p Egress Blocking [Disabled]
If supported by hardware and set to Enabled, outbound Atomic0p Requests via Egress
Portswillbeblocked.
Congurationoptions:[Disabled][Enabled]
IDO Request Enable [Disabled]
If supported by hardware and set to Enabled, this permits setting the number of ID-
BasedOrdering(IDO)bit(Attribute[2])requeststobeinitiated.
Congurationoptions:[Disabled][Enabled]
IDO Completion Enable [Disabled]
If supported by hardware and set to Enabled, this permits setting the number of ID-
BasedOrdering(IDO)bit(Attribute[2])requeststobeinitiated.
Congurationoptions:[Disabled][Enabled]
LTR Mechanism Enable [Disabled]
If supported by hardware and set to Enabled,thisenablestheLatencyTolerance
Reporting(LTR)Mechanism.
Congurationoptions:[Disabled][Enabled]
IDO Request Enable [Disabled]
If supported by hardware and set to Enabled, this permits setting the number of ID-
BasedOrdering(IDO)bit(Attribute[2])requeststobeinititated.
Congurationoptions:[Disabled][Enabled]
End-End TLP Prefix Blocking [Disabled]
If supported by hardware and set to Enabled,thisfunctionwillblockforwardingof
TLPscontainingEnd-EndTLPPrexes.
Congurationoptions:[Disabled][Enabled]
PCI Express GEN2 Device Register Settings
Target Link Speed [Auto]
If supported by hardware and set to Force to X.X GT/s, for Downstream Ports, this
setsanupperlimitonLinkoperationalspeedbyrestrictingthevaluesadvertisedbythe
Upstreamcomponentinitstrainingsequences.WhenAutoisselectedHWinitialized
data will be used.
Congurationoptions:[Auto][Forceto2.5GT/s][Forceto5.0GT/s][Forceto8.0GT/s]
4-21
Z11PA-U12 Series
Clock Power Management [Disabled]
If supported by hardware and set to Enabled,thedeviceispermittedtouseCLKREQ#
signalforpowermanagementofLinkclockinaccordancetoprotocoldenedin
appropriateformfactorspecication.
Congurationoptions:[Disabled][Enabled]
Compliance SOS [Disabled]
If supported by hardware and set to Enabled,thiswillforceLTSSMtosendSKP
OrderedSetsbetweensequenceswhensendingCompliancePatternorModied
Compliance Pattern.
Congurationoptions:[Disabled][Enabled]
Hardware Autonomous Width [Enabled]
If supported by hardware and set to Disabled,thiswilldisablethehardware’sabilityto
changelinkwidthexceptforwidthsizereductionforthepurposeofcorrectingunstable
linkoperation.
Congurationoptions:[Disabled][Enabled]
Hardware Autonomous Speed [Enabled]
If supported by hardware and set to Disabled,thiswilldisablethehardware’sability
tochangelinkspeedexceptforspeedratereductionforthepurposeofcorrecting
unstablelinkoperation.
Congurationoptions:[Disabled][Enabled]
PCIE OPROM Slot Options
PCIE1-6 Slot OPROM [Enabled]
This option allows you to enable or disable the OPROM of the PCIe slots.
Congurationoptions:[Disabled][Enabled]
4-22 Chapter 4: BIOS Setup
4.4.9 Network Stack Configuration
Allowsyoutocongurethenetwordstackconguration.
Network Stack [Disabled]
AllowsyoutoenableordisableUEFINetworkStack.
Congurationoptions:[Disabled][Enabled]
The following items appear only when you set the Network Stack to [Enabled].
Ipv4 PXE Support [Disabled]
EnablesordisablestheIpv4PXEBootSupport.Ifdisabled,Ipv4PXEbootoptionwill
not be created.
Congurationoptions:[Disable][Enable]
Ipv4 HTTP Support [Disabled]
EnablesordisablestheIpv4HTTPBootSupport.Ifdisabled,Ipv4PXEbootoptionwill
not be created.
Congurationoptions:[Disable][Enable]
Ipv6 PXE Support [Disabled]
EnablesordisablestheIpv6PXEBootSupport.Ifdisabled,Ipv6PXEbootoptionwill
not be created.
Congurationoptions:[Disable][Enable]
Ipv6 HTTP Support [Disabled]
EnablesordisablestheIpv6HTTPBootSupport.Ifdisabled,Ipv6PXEbootoptionwill
not be created.
Congurationoptions:[Disable][Enable]
PXE boot wait time [0]
SetthewaittimetopressESCkeytoabortthePXEboot.Usethe<+>or<->toadjust
the value. The values range from 0 to 5.
Media detect count [1]
Setthenumberoftimespresenceofmediawillbechecked.Usethe<+>or<->to
adjustthevalue.Thevaluesrangefrom1to50.
4-23
Z11PA-U12 Series
4.4.10 CSM Configuration
CSM Support [Enabled]
This option allows you to enable or disable CSM Support.
Congurationoptions:[Disabled][Enabled]
The following items appear only when you set the CSM Support to [Enabled].
GateA20 Active [Upon Request]
This allows you to set the GA20 option.
[UponRequest] GA20canbedisabledusingBIOSservices.
[Always] DonotallowdisablingGA20;thisoptionisusefulwhenanyRT
code is executed above 1MB.
Option ROM Messages [Force BIOS]
This allows you to set the display mode for option ROM.
Congurationoptions:[ForceBIOS][KeepCurrent]
INT19 Trap Response [Immediate]
This option allows you to control the BIOS reaction on INT19 trapping by Option ROM.
[Immediate] Executethetraprightaway.
[Legacyonly] Executethetrapduringlegacyboot.
Boot Option filter [Legacy only]
ThisoptionallowsyoutocontroltheLegacy/UEFIROMspriority.
Congurationoptions:[UEFIandLegacy][Legacyonly][UEFIonly]
Network / Storage / Video [Legacy]
ThisoptionallowsyoutocontroltheexecutionofUEFIandLegacyPXE/Storage/
Video OpROM.
Congurationoptions:[UEFI][Legacy]
Other PCI devices [Legacy]
ThisitemdeterminestheOpROMexecutionpolicyfordevicesotherthanNetwork,
Storage, or Video.
Congurationoptions:[UEFI][Legacy]
4-24 Chapter 4: BIOS Setup
4.4.12 USB Configuration
Legacy USB Support [Enabled]
[Disabled] TheUSBdevicescanbeusedonlyfortheBIOSsetupprogram.Itcannot
be recognized in boot devices list.
[Enabled] EnablesthesupportforUSBdevicesonlegacyoperatingsystems(OS).
[Auto] AllowsthesystemtodetectthepresenceofUSBdevicesatstartup.If
detected, the USB controller legacy mode is enabled. If no USB device is
detected, the legacy USB support is disabled.
USB Mass Storage Driver Support [Enabled]
Allows you to enable or disable the USB Mass Storage driver support.
Congurationoptions:[Disabled][Enabled]
Mass Storage Devices
Allows you to select the mass storage device emulation type for devices connected.
Congurationoptions:[Auto][Floppy][ForcedFDD][HardDisk][CD-ROM]
4.4.11 NVMe Configuration
You may view the NVMe controller and Drive information if an NVMe device is connected.
4-25
Z11PA-U12 Series
4.4.13 iSCSI Configuration
AllowsyoutoconguretheiSCSiparameters.
4.4.14 Intel(R) Virtual RAID on CPU
AllowsyoutoconguretheviewtheRAIDvolumesandVMDcontrollersonthesystem.
4-26 Chapter 4: BIOS Setup
PCH Devices
Board Capability [DeepSx]
[SUS_PWR_DN_ACK] Send.
[DeepSx] ShowDeepSxPolicies.
DeepSx Power Policies [Disabled]
AllowsyoutoconguretheDeepSxModeconguration.
Congurationoptions:[Disabled][EnabledinS5][EnabledinS4andS5]
GP27 Wake From DeepSx [Disabled]
AllowsyoutoenableordisableGP27WakeFromDeepSx.
Congurationoptions:[Disabled][Enabled]
PCI Express Configuration
PCI-E ASPM Support (Global) [L1 Only]
Allows you to select ASPM support for all downstream devices.
Congurationoptions:[Perindividualport][L1Only]
PCH DMI ASPM [Platform-POR]
AllowsyoutocongurethePCHDMIASPM.
Congurationoptions:[Platform-POR][ASPML1][Disabled]
4.5.1 PCH Configuration
4.5 Platform Configuration menu
The IntelRCSetup menu items allow you to change the platform settings.
TakecautionwhenchangingthesettingsofthePlatformCongurationmenuitems.
Incorrecteldvaluescancausethesystemtomalfunction.
4-27
Z11PA-U12 Series
PCH SATA Configuration
SATA Controller [Enabled]
Allows you to enable or disable the SATA Controller.
Congurationoptions:[Disabled][Enabled]
The following item appears only when you set SATA Controller to [Enabled].
Configure SATA as [AHCI]
AllowsyoutoidentifytheSATAportconnectedtoSolidStateDriveorHardDiskDrive.
Congurationoptions:[AHCI][RAID]
Support Aggressive Link Power Management [Enabled]
AllowsyoutoenableordisabletheSupportAggressiveLinkPower(SALP)
Management.
Congurationoptions:[Disabled][Enabled]
SATA Port 0-7
Port 0-7
Allows you to enable or disable the SATA port.
Congurationoptions:[Disabled][Enabled]
PCH sSATA Configuration
sSATA Controller [Enabled]
Allows you to enable or disable the sSATA Controller.
Congurationoptions:[Disabled][Enabled]
The following item appears only when you set sSATA Controller to [Enabled].
Configure sSATA as [AHCI]
AllowsyoutoidentifytheSATAportconnectedtoSolidStateDriveorHardDiskDrive.
Congurationoptions:[AHCI][RAID]
Support Aggressive Link Power Management [Enabled]
AllowsyoutoenableordisabletheSupportAggressiveLinkPower(SALP)
Management.
Congurationoptions:[Disabled][Enabled]
sSATA Port 0-5
Port 0-5
Allows you to enable or disable the SATA port.
Congurationoptions:[Disabled][Enabled]
USB Configuration
USB Precondition [Disabled]
AllowsyoutoenableordisablepreconditionworkonUSBhostcontrollerandroot
ports for faster enumeration.
Congurationoptions:[Disabled][Enabled]
4-28 Chapter 4: BIOS Setup
XHCI Manual Mode [Disabled]
This option is used by validation.
Congurationoptions:[Disabled][Enabled]
The following items appear only when the XHCI Manual Mode is set to [Enabled].
Trunk Clock Gating (BTCG) [Enabled]
Allows you to enable or disable BTCG.
Congurationoptions:[Disabled][Enabled]
Enable USB 3.0 pins [Disable all pins]
Allows you to enable or disable USB 3.0 pins or on a per pin basis.
Congurationoptions:[SelectPer-Pin][Disableallpins][Enableallpins]
USB Per-Connector Disable [Disabled]
Allows you to enable or disable each of the USB physical connectors. Once a
connector is disabled, any USB devices plugged into the connector will not be detected
by BIOS or OS.
Congurationoptions:[Disabled][Enabled]
The following items appear only when the USB Per-Connector Disable is set to
[Enabled].
USB HS Physical Connector #0-13 Disable [Enabled]
Congurationoptions:[Disabled][Enabled]
USB SS Physical Connector #0-9 Disable [Enabled]
Congurationoptions:[Disabled][Enabled]
Security Configuration
SMM BIOS Write Protect [Enabled]
AllowsyoutoenableordisableSMMBIOSWriteProtect.
Congurationoptions:[Disabled][Enabled]
DCI Auto Detect Enable [Disabled]
Whenenabled,itdetectsDCIbeingconnectedduringBIOSPOSTtimeandenablesDCI.
Congurationoptions:[Disabled][Enabled]
4-29
Z11PA-U12 Series
4.5.2 Miscellaneous Configuration
Active Video [Offboard Device]
Allows you to select the video type.
Congurationoptions:[OnboardDevice][OffboardDevice]
PMTT ACPI Table [Disabled]
Allows you to enable or disable PMTT ACPI Table for DDR4 only.
Congurationoptions:[Disabled][Enabled]
4.5.3 Server ME Configuration
Displays the Server ME Technology parameters on your system.
Toquicklygotothelastitemofthesecondpage,pressthe Page Down button. Press the
Page Upbuttontogobacktotherstitemintherstpage.
Navigate to the second page of the screen to see the rest of items in this menu by pressing
theUporDownarrowkeys.
4-30 Chapter 4: BIOS Setup
4.5.4 Runtime Error Logging
Displays the Server ME Technology parameters on your system.
System Errors [Enabled]
This item allows you to enable or disable System Errors.
Congurationoptions:[Disabled][Enabled]
Whea Settings
Whea Support [Enabled]
ThisitemallowsyoutoenableordisabletheWHEAsupport.
Congurationoptions:[Disabled][Enabled]
4-31
Z11PA-U12 Series
4.6 Socket Configuration menu
TheIntelRCSetupmenuitemsallowyoutochangethesocketsettings.
4.6.1 Processor Configuration
Toquicklygotothelastitemofthesecondpage,pressthe Page Down button. Press the
Page Upbuttontogobacktotherstitemintherstpage.
Navigate to the second page of the screen to see the rest of items in this menu by pressing
theUporDownarrowkeys.
Hyper-threading [ALL] [Enabled]
This item allows a hyper-threading processor to appear as two logical processors, allowing
the operating system to schedule two threads or processors simultaneously.
Congurationoptions:[Disabled][Enabled]
4-32 Chapter 4: BIOS Setup
Execute Disable Bit [Enabled]
XDcanpreventcertainclassesofmaliciousbufferoverowattackswhencombinedwith
asupportingOS(WindowsServer2003SP1,WindowsXPSP2,SuSELinux9.2,Redhat
Enterprise 3 Update 3).
Congurationoptions:[Disabled][Enabled]
Enable Intel(R) TXT [Disabled]
ForcestheXDfeaturelogtoalwaysreturn0whendisabled.
Congurationoptions:[Disabled][Enabled]
VMX [Enabled]
EnablestheVanderpoolTechnology.Takeseffectafterreboot.
Congurationoptions:[Disabled][Enabled]
Enable SMX [Disabled]
Enables the Safer Mode Extensions.
Congurationoptions:[Disabled][Enabled]
Hardware Prefetcher [Enabled]
ThisItemallowsyoutoturnon/offthemidlevelcache(L2)streamerprefetcher.
Congurationoptions:[Disabled][Enabled]
Adjacent Cache Prefetch [Enabled]
ThisItemallowsyoutoturnon/offprefetchingofadjacentcachelines.
Congurationoptions:[Disabled][Enabled]
DCU Streamer Prefetcher [Enabled]
ThisItemallowsyoutoenableordisableprefetcherofnextL1dataline.
Congurationoptions:[Disabled][Enabled]
DCU IP Prefetcher [Enabled]
ThisItemallowsyoutoenableordisableprefetchofnextL1linebaseduponsequentialload
history.
Congurationoptions:[Disabled][Enabled]
LLC Prefetch [Disabled]
ThisItemallowsyoutoenableordisableLLCPrefetchonallthreads.
Congurationoptions:[Disabled][Enabled]
DCU Mode [32KB 8Way Without ECC]
Congurationoptions:[32KB8WayWithoutECC][16KB4WayWithECC]
Extended APIC [Disabled]
This Item allows you to enable or disable the extended APIC support.
Congurationoptions:[Disabled][Enabled]
AES-NI [Enabled]
This Item allows you to enable or disable the AES-NI support.
Congurationoptions:[Disabled][Enabled]
4-33
Z11PA-U12 Series
4.6.2 Common RefCode Configuration
Numa [Enabled]
This item enables or disables the Non uniform Memory Access (NUMA).
Congurationoptions:[Disabled][Enabled]
4.6.3 UPI Configuration
UPI General Configuration
UPI Status
This item displays information about the UPI status.
Link Speed Mode [Fast]
ThisitemallowsyoutoselecttheUPIlinkspeedaseitherthefastmodeorslowmode.
Congurationoptions:[Slow][Fast]
Link Frequency Select [Auto]
ThisitemallowsforselectingtheUPIlinkfrequency.
Congurationoptions:[Auto][9.6GB/s][10.4GB/s][UsePerLinkSetting]
Link0p Enable [Auto]
Congurationoptions:[Disabled][Enabled][Auto]
Link1 Enable [Auto]
Congurationoptions:[Disabled][Enabled][Auto]
Stale AtoS [Disabled]
Congurationoptions:[Disabled][Enabled][Auto]
LLC dead line alloc [Enabled]
Congurationoptions:[Disabled][Enabled][Auto]
4-34 Chapter 4: BIOS Setup
4.6.4 Memory Configuration
Enforce POR [Auto]
Allows you to enforce POR restrictions for DDR4 frequency and voltage programming.
Congurationoptions:[Auto][POR][Disabled]
Memory Frequency [Auto]
Allows you to select the memory frequency setting.
Congurationoptions:[Auto][2133][2400][2666]
Data Scrambling for DDR4 [Auto]
Allows you to enable or disable data scrambling.
Congurationoptions:[Auto][Disabled][Enabled]
Memory Topology
Displays memory topology with DIMM population information.
Page Policy
AllowsyoutocongurePagePolicysettings.
Page Policy [Auto]
Congurationoptions:[Auto][Closed][Adaptive]
Memory Map
IMC Interleaving [Auto]
Select different IMC interleaving setting.
Congurationoptions:[Auto][1-wayInterleave][2-wayInterleave]
Channel Interleaving [Auto]
Select different channel interleaving setting.
Congurationoptions:[Auto][1-wayInterleave][2-wayInterleave]
[3-wayInterleave]
Rank Interleaving [Auto]
Selectdifferentrankinterleavingsetting.
Congurationoptions:[Auto][1-wayInterleave][2-wayInterleave]
[4-wayInterleave][8-wayInterleave]
4-35
Z11PA-U12 Series
4.6.5 IIO Configuration
Memory RAS Configuration
Mirror mode [Disabled]
AllowsyoutoselectMirrormodes.Mirrormodewillsetentire1LM/2LMmemoryin
system to be mirrored, consequently reducing the memory capacity by half. Enabling
MirrormodewilldisableXPTPrefetch.
Congurationoptions:[Disabled][MirrorMode1LM][MirrorMode2LM]
Mirror TAD0 [Disabled]
Allows you to enable or disable Mirror on entire memory for TAD0.
Congurationoptions:[Disabled][Enabled]
Enable Partial Mirror [Disabled]
Partialmirrormodewillenabletherequiredsizeofmemorytobemirrored.Ifrank
sparingisenabled,partialmirroringwillnottakeeffect.MirrorEnablewilldisableXPT
Prefetch.
Congurationoptions:[Disabled][Enabled]
UEFI ARM Mirror [Disabled]
Allows you to enable or disable UEFI ARM Mirror.
Congurationoptions:[Disabled][Enabled]
Memory Rank Sparing [Disabled]
AllowsyoutoenableordisableMemoryRankSparing
Congurationoptions:[Disabled][Enabled]
Patrol Scrub [Enabled]
Allows you to enable or disable Patrol Scrub.
Congurationoptions:[Disabled][Enabled]
Socket1 Configuration
This option allows you to change the settings related to the PCI Express Ports.
4-36 Chapter 4: BIOS Setup
Intel® VT for Directed I/O (VT-d)
Intel® VT for Directed I/O (VT-d) [Enabled]
Allows you to enable or disable the Intel Virtualization Technology for Directed I/O.
Congurationoptions:[Disabled][Enabled]
IIO-PCIE Express Global Options
PCIE relaxed Ordering [Enabled]
Allows you to enable or disable PCIE relaxed Ordering.
Congurationoptions:[Disabled][Enabled]
4.6.6 Advanced Power Management Configuration
CPU P State Control
Boot performance mode [Max Performance]
Allows you to switch between Boot performance mode.
Congurationoptions:[MaxPerformance][MaxEfcient][SetbyIntelNodeManager]
Energy Efficient Turbo [Enabled]
AllowsyoutoenableordisableEnergyEfcientTurbo.
Congurationoptions:[Disabled][Enabled]
Turbo Mode [Enabled]
Allows you to enable or disable Turbo Mode.
Congurationoptions:[Disabled][Enabled]
Hardware PM State Control
Hardware P-States [Native Mode]
Allows you to switch between Hardware P-States mode.
Congurationoptions:[Disabled][NativeMode][OutofBandMode]
[NativeModewithnoLegacySupport]
CPU C State Control
Autonomous Core C-State [Disabled]
Allows you to enable or disable Autonomous Core C-State Report.
Congurationoptions:[Disabled][Enabled]
CPU C6 Report [Auto]
Allows you to select CPU C6 Report.
Congurationoptions:[Disabled][Enabled][Auto]
4-37
Z11PA-U12 Series
OS ACPI Cx [ACPI C2]
Allows you to select OS ACPI Cx Report.
Congurationoptions:[ACPIC2][ACPIC3]
Package C State Control
Package C State [Auto]
AllowsyoutoselectPackageCState.
Congurationoptions:[C0/C1state][C2state][C6(nonRetentionstate)]
[C6(Retentionstate)][NoLimit][Auto]
CPU Thermal Control
CPU T State Control
Software Controlled T-States [Disabled]
Allows you to enable or disable Software Controlled T-States.
Congurationoptions:[Disabled][Enabled]
CPU - Advanced PM Tuning
Energy Perf BIAS
Power Performance Tuning
Congurationoptions:[OSControlsEPB][BIOSControlsEPB]
The following item appears only when you set Power Performance Tuning to
[OS Controls EPB].
PECI PCS EPB
This option controls whether PECI has control over EPB.
Congurationoptions:[OSControlsEPB][PECIControlsEPBusingPCS]
The following item appears only when you set Power Performance Tuning to
[BIOS Controls EPB].
ENERGY_PERF_BIAS_CFG Mode
Congurationoptions:[Performance][BalancedPerformance][BalancedPower]
[Power]
Dynamic Loadline Switch
Congurationoptions:[Disabled][Enabled]
Workload Configuration
Thisoptionallowsoptimizationfortheworkloadcharacterization.
Congurationoptions:[UMA][NUMA]
4-38 Chapter 4: BIOS Setup
Averaging Time Window
This option is used to control the effective window of the average C0 an P0 time.
Congurationoptions:[0]-[99]
P0 TotalTimeThreshold Low
TheHWswitchingmechanismDISABLEStheperformancesetting(0)whenthetotal
P0 time is less than the threshold set.
Congurationoptions:[0]-[99]
P0 TotalTimeThreshold High
TheHWswitchingmechanismEnablestheperformancesetting(0)whenthetotalP0
time is greater than the threshold set.
Congurationoptions:[0]-[99]
4-39
Z11PA-U12 Series
Enabling/Disabling Options
Smbios Event Log [Enabled]
ChangethistoenableordisableallfeaturesofSmbiosEventLoggingduringboot.
Congurationoptions:[Disabled][Enabled]
Erasing Settings
Erase Event Log [No]
ChooseoptionsforerasingSmbiosEventLog.Erasingisdonepriortoanyloggingactivation
during reset.
Congurationoptions:[No][Yes,Nextreset][Yes,Everyreset]
4.7.2 View Smbios Event Log
Press <Enter> to view all smbios event logs.
4.7 Event Logs menu
4.7.1 Change Smbios Event Log Settings
Press<Enter>tochangetheSmbiosEventLogconguration.
Allvalueschangedheredonottakeeffectuntilcomputerisrestarted.
4-40 Chapter 4: BIOS Setup
4.8 Server Mgmt menu
OS Watchdog Timer [Disabled]
This item allows you to start a BIOS timer which can only be shut off by Intel Management
Software after the OS loads.
Congurationoptions:[Disabled][Enabled]
ThefollowingitemsarecongurableonlywhentheOS Watchdog Timer is set to [Enabled].
OS Wtd Timer Timeout [10 minutes]
AllowsyoutocongurethelengthfortheOSBootWatchdogTimer.
Congurationoptions:[5minutes][10minutes][15minutes][20minutes]
OS Wtd Timer Policy [Reset]
ThisitemallowsyoutocongurethehowthesystemshouldrespondiftheOSBoot
WatchTimerexpires.
Congurationoptions:[DoNothing][Reset][PowerDown]
4.8.1 System Event Log
AllowsyoutochangetheSELeventlogconguration.
Allvalueschangedheredonottakeeffectuntilcomputerisrestarted.
Erase SEL [No]
AllowsyoutochooseoptionsforerasingSEL.
Congurationoptions:[No][Yes,Onnextreset][Yes,Oneveryreset]
When SEL is Full [Do Nothing]
AllowsyoutochooseoptionsforreactionstoafullSEL.
Congurationoptions:[DoNothing][EraseImmediately]
4-41
Z11PA-U12 Series
4.8.2 BMC network configuration
Thesub-itemsinthiscongurationallowyoutoconguretheBMCnetworkparameters.
IPV4
DM_LAN1/ Shared LAN
Config Address source [Previous State]
ThisitemallowsyoutocongureLANchannelparametersstatisticallyordynamically(by
BIOSorBMC).UnspeciedoptionwillnotmodifyanyBMCnetworkparametersduringBIOS
phase.
Congurationoptions:[PreviousState][Static][DynamicBmcDhcp][DynamicBmcNonDhcp]
IPV6
DM_LAN1/ Shared LAN
IPV6 Support [Enabled]
AllowsyoutoenableordisableLAN1IPV6Support.
Congurationoptions:[Disabled][Enabled]
Toquicklygotothelastitemofthesecondpage,pressthe Page Down button. Press the
Page Upbuttontogobacktotherstitemintherstpage.
Navigate to the second page of the screen to see the rest of items in this menu by pressing
theUporDownarrowkeys.
4-42 Chapter 4: BIOS Setup
4.8.3 View System Event Log
This item allows you to view the system event log records.
Config Address source [Previous State]
ThisitemallowsyoutocongureLANchannelparametersstatisticallyordynamically(by
BIOSorBMC).UnspeciedoptionwillnotmodifyanyBMCnetworkparametersduringBIOS
phase.
Congurationoptions:[PreviousState][Static][DynamicBmcDhcp][DynamicBmcNonDhcp]
4-43
Z11PA-U12 Series
4.9 Security menu
This menu allows a new password to be created or a current password to be changed. The
menualsoenablesordisablestheSecureBootstateandletstheuserconguretheSystem
Mode state.
Administrator Password
To set an administrator password:
1. Select the Administrator Password item and press <Enter>.
2.FromtheCreateNewPasswordbox,keyinapassword,thenpress<Enter>.
3.Conrmthepasswordwhenprompted.
To change an administrator password:
1. Select the Administrator Password item and press <Enter>.
2.FromtheEnterCurrentPasswordbox,keyinthecurrentpassword,thenpress<Enter>.
3.FromtheCreateNewPasswordbox,keyinanewpassword,thenpress<Enter>.
4.Conrmthepasswordwhenprompted.
To clear the administrator password, follow the same steps as in changing an administrator
password,butpress<Enter>whenpromptedtocreate/conrmthepassword.
4-44 Chapter 4: BIOS Setup
User Password
To set a user password:
1. Select the User Password item and press <Enter>.
2.FromtheCreateNewPasswordbox,keyinapassword,thenpress<Enter>.
3.Conrmthepasswordwhenprompted.
To change a user password:
1. Select the User Password item and press <Enter>.
2.FromtheEnterCurrentPasswordbox,keyinthecurrentpassword,thenpress<Enter>.
3.FromtheCreateNewPasswordbox,keyinanewpassword,thenpress<Enter>.
4.Conrmthepasswordwhenprompted.
To clear a user password:
1. Select the Clear User Password item and press <Enter>.
2.SelectYesfromtheWarningmessagewindowthenpress<Enter>.
Secure Boot
This item allows you to customize the Secure Boot settings.
Attempt Secure Boot [Disabled]
Secure Boot can be enabled if the system is running in User mode with enrolled platform Key
(EPK) or if the CSM function is disabled.
Congurationoptions:[Disabled][Enabled]
Secure Boot Mode [Custom]
Allows you to set the Secure Boot selector.
Congurationoptions:[Custom][Standard]
4-45
Z11PA-U12 Series
Key Management
ThisitemonlyappearswhentheitemSecureBootModeissetto[Custom].TheKey
Management item allows you to modify Secure Boot variables and set Key Management
page.
Provision Factory Defaults [Disabled]
AllowsyoutoprovisionfactorydefaultSecureBootkeyswhenthesystemisinSetup
Mode.
Congurationoptions:[Disabled][Enabled]
Install Factory Default keys
ThisitemwillinstallallFactoryDefaultkeys.
Reset to Setup Mode
ThisitemappearsonlywhenyouloadthedefaultSecureBootkeys.Thisitemallows
youtoclearalldefaultSecureBootkeys.
Enroll Efi Image
This item will allow the image to run in Secure Boot mode.
Save All Secure Boot Variables
Thisitemwillaskyouifyouwanttosaveallsecurebootvariables.SelectYesifyou
want to save all secure boot variables, otherwise select No.
Platform Key (PK)
Congurationoptions:[SavetoFile][SetNew][Erase]
Key Exchange Keys / Authorized Signatures / Forbidden Signatures
Congurationoptions:[SavetoFile][SetNew][Append][Erase]
Authorized TimeStamps
Congurationoptions:[SetNew][Append]
OsRecovery Signatures
Congurationoptions:[SetNew][Append]
4-46 Chapter 4: BIOS Setup
4.10 Boot menu
The Boot menu items allow you to change the system boot options.
Bootup NumLock State [On]
Allowsyoutoselectthepower-onstatefortheNumLock.
Congurationoptions:[Off][On]
Boot Logo Display [Disabled]
Allows you to enable or disable the full screen logo display feature.
Congurationoptions:[Auto][FullScreen][Disabled]
The following item appears only when you set the Boot Logo Display to [Disabled].
POST Report [5 sec]
Allows you to set the desired POST Report waiting time from 1 to 10 seconds.
Congurationoptions:[1sec]~[10sec][UntilPressESC]
Boot Option Priorities
These items specify the boot device priority sequence from the available devices. The
number of device items that appears on the screen depends on the number of devices
installed in the system.
• Toselectthebootdeviceduringsystemstartup,press<F8>whenASUSLogo
appears.
• ToaccessWindowsOSinSafeMode,pleasepress<F8>afterPOST.
Network Device BBS Priorities
Thisitemallowsyoutosetthebootingfromnetwork.
Hard Drive / Floppy Drive BBS Priorities
These items appear only when you connect SATA ODD or hard drive to the SATA ports and
allow you to set the booting order of the SATA devices.
4-47
Z11PA-U12 Series
4.11 Tool menu
TheToolmenuitemsallowyoutocongureoptionsforspecialfunctions.Selectanitemthen
press <Enter> to display the submenu.
IPMI HWM
Allows you to run the IPMI hardware monitor.
Start EzFlash
Allows you to run ASUS EzFlash BIOS ROM Utility when you press <Enter>. Refer to the
ASUS EzFlash Utility section for details.
4.12 Save & Exit menu
The Exit menu items allow you to save or discard your changes to the BIOS items.
Discard Changes and Exit
Exit System setup without saving any changes.
Save Changes and Reset
Exit System setup after saving the changes.
Restore Defaults
Restore/load default values for all the setup options.
Pressing <Esc> does not immediately exit this menu. Select one of the options from this
menu or <F10> from the legend bar to exit.
4-48 Chapter 4: BIOS Setup
Boot Override
These items displays the available devices. The device items that appears on the screen
dependsonthenumberofdevicesinstalledinthesystem.Clickanitemtostartbootingfrom
the selected device.
Launch EFI Shell from filesystem device
ThisitemallowsyoutoattempttolaunchtheEFIShellapplication(shellx64.e)fromoneof
theavailablelesystemdevices.
5
RAID Conguration
This chapter provides instructions for setting up, creating,
and conguring RAID sets using the available utilities.
Chapter 5: RAID Conguration
5-2 Chapter 5: RAID Conguration
If you want to boot the system from a hard disk drive included in a created RAID set, copy
rst the RAID driver from the support DVD to a oppy disk before you install an operating
system to the selected hard disk drive.
5.1 RAID configurations
The motherboard supports Intel® Rapid Storage Technology enterprise Option ROM Utility
with RAID 0, RAID 1, RAID 10, and RAID 5 support.
If you want to install a Windows® operating system to a hard disk drive included in a RAID
set, you have to create a RAID driver disk and load the RAID driver during OS installation.
Refer to section 6.1 RAID driver installation for details.
5.1.1 RAID definitions
RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in
parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a
sustained data transfer rate, double that of a single disk alone, thus improving data access
and storage. Use of two new identical hard disk drives is required for this setup.
RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to
a second drive. If one drive fails, the disk array management software directs all applications
to the surviving drive as it contains a complete copy of the data in the other drive. This RAID
conguration provides data protection and increases fault tolerance to the entire system. Use
two new drives or use an existing drive and a new drive for this setup. The new drive must be
of the same size or larger than the existing drive.
RAID 5 stripes both data and parity information across three or more hard disk drives. Among
the advantages of RAID 5 conguration include better HDD performance, fault tolerance, and
higher storage capacity. The RAID 5 conguration is best suited for transaction processing,
relational database applications, enterprise resource planning, and other business systems.
Use a minimum of three identical hard disk drives for this setup.
RAID 10 is data striping and data mirroring combined without parity (redundancy data) having
to be calculated and written. With the RAID 10 conguration you get all the benets of both
RAID 0 and RAID 1 congurations. Use four new hard disk drives or use an existing drive
and three new drives for this setup.
5-3
Z11PA-U12 Series
5.1.2 Installing Serial ATA hard disks
The motherboard supports Serial ATA hard disk drives. For optimal performance, install
identical drives of the same model and capacity when creating a disk array.
To install the SATA hard disks for a RAID conguration:
1. Install the SATA hard disks into the drive bays.
2. Connect the SATA signal cables.
3. Connect a SATA power cable to the power connector on each drive.
5.1.3 Setting the RAID item in BIOS
You must set the RAID item in the BIOS Setup before you can create a RAID set from SATA
hard disk drives attached to the SATA connectors supported by Intel® C620 chipset.
To do this:
1. Enter the BIOS Setup during POST.
2. Go to the Platform Configuration menu > PCH Configuration menu > PCH SATA
Configuration, then press <Enter>.
3. Set Configure SATA as to [RAID Mode].
4. Press <F10> to save your changes and exit the BIOS Setup.
Refer to Chapter 4 for details on entering and navigating through the BIOS Setup.
5.1.4 RAID configuration utilities
Depending on the RAID connectors that you use, you can create a RAID set using the utilities
embedded in each RAID controller. For example, use the Intel® Rapid Storage Technology
if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the
Intel® C620 chipset.
Refer to the succeeding section for details on how to use the RAID conguration utility.
5-4 Chapter 5: RAID Conguration
5.2 Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM Utility
The Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM utility allows you
to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set from Serial ATA hard disk
drives that are connected to the Serial ATA connectors supported by the Southbridge.
The navigation keys at the bottom of the screen allow you to move through the menus
and select the menu options.
The RAID BIOS setup screens shown in this section are for reference only and may not
exactly match the items on your screen.
To launch the Intel® Rapid Storage Technology enterprise SATA/SSATA Option ROM utility:
1. Turn on the system.
2. During POST, press <Ctrl>+<I> to display the utility main menu.
Before you proceed, ensure that you have installed the Serial ATA hard disk drives, and
have set the correct SATA mode in the BIOS setup. You can refer to the Installing Serial
ATA hard disks, and Setting the RAID item in BIOS sections in this manual for more
information.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes:
None defined.
Physical Disks:
ID Drive Model Serial # Size Type/Status(Vol ID)
0 ST3300656SS HWAS0000991753TR 279.3GB Non-RAID Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Non-RAID Disk
2 ST3300656SS 397600009846UEDY 279.3GB Non-RAID Disk
3 ST3300656SS GWC50000991756G6 279.3GB Non-RAID Disk
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
5-5
Z11PA-U12 Series
5.2.1 Creating a RAID set
To create a RAID set:
1. From the utility main menu, select 1. Create RAID Volume and press <Enter>.
2. Key in a name for the RAID set and press <Enter>.
3. Press the up/down arrow keys to select a RAID Level that you wish to create then
press <Enter>.
4. From the Disks item eld, press <Enter> to select the hard disk drives that you want to
include in the RAID set.
5. Use the up/down arrow keys to move the selection bar then press <Space> to select a
disk. A small triangle before the Port number marks the selected drive. Press <Enter>
when you are done.
[ESC]-Previous Menu [ENTER]-Select[ ]Change
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
[ HELP ]
Name:
RAID Level:
Disks:
Strip Size:
Capacity:
Syne:
Create Volume
Enter a unique volume name that has no special characters and is
16 characters or less.
Volume0
RAID0(Strips)
Select Disks
128KB
0.0 GB
N/A
[TAB]-Next
[ SELECT DISKS ]
Port Drive Model Serial # Size Status
0 ST3300656SS HWAS0000991753TR 279.3GB Non-RAID Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Non-RAID Disk
2 ST3300656SS 397600009846UEDY 279.3GB Non-RAID Disk
3 ST3300656SS GWC50000991756G6 279.3GB Non-RAID Disk
Select 1 Master and 1 Recovery disk to create volume.
[ ]-Prev/Next [TAB]-(M)aster [SPACE]-(R)ecovery [ENTER]-Done
5-6 Chapter 5: RAID Conguration
6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0,
10 and 5 only) then press <Enter>. The available stripe size values range from 4 KB to
128 KB. The following are typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
We recommend a lower stripe size for server systems, and a higher stripe size for
multimedia computer systems used mainly for audio and video editing.
7. In the Capacity eld item, key in the RAID volume capacity that you want to use and
press <Enter>. The default value eld indicates the maximum allowed capacity.
8. Press <Enter> to start creating the RAID volume.
9. From the following warning message, press <Y> to create the RAID volume and return
to the main menu, or press <N> to go back to the CREATE VOLUME menu.
WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.
Are you sure you want to create this volume? (Y/N):
5-7
Z11PA-U12 Series
5.2.2 Deleting a RAID set
Take caution when deleting a RAID set. You will lose all data on the hard disk drives when
you delete a RAID set.
To delete a RAID set:
1. From the utility main menu, select 2. Delete RAID Volume and press <Enter>.
2. From the Delete Volume Menu, press the up/down arrow keys to select the RAID set
you want to delete then press <Del>.
3. Press <Y> to conrm deletion of the selected RAID set and return to the utility main
menu, or press <N> to return to the DELETE VOLUME menu.
[ESC]-Previous Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ DELETE VOLUME MENU ]
[ HELP ]
Deleting a volume will reset the disks to non-RAID
WARNING: ALL DISK DATA WILL BE DELETED.
(This does not apply to Recovery volumes)
[DEL]-Delete Volume
Name Level Drives Capacity Status Bootable
Volume0 RAID0(Stripe) 2 298.0GB Normal Yes
ALL DATA IN THE VOLUME WILL BE LOST!
(This does not apply to Recovery volumes)
Are you sure you want to delete volume “Volume0”? (Y/N):
[ DELETE VOLUME VERIFICATION ]
5-8 Chapter 5: RAID Conguration
5.2.3 Resetting disks to Non-RAID
Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a
RAID volume hard disk drive deletes all internal RAID structure on the drive.
To reset a RAID set:
1. From the utility main menu, select 3. Reset Disks to Non-RAID and press <Enter>.
2. Press the up/down arrow keys to select the drive(s) or disks of the RAID set you want
to reset, then press <Space>. A small triangle before the Port number marks the
selected drive. Press <Enter> when you are done.
3. Press <Y> in the conrmation window to reset the drive(s) or press <N> to return to the
utility main menu.
Port Drive Model Serial # Size Status
0 ST3300656SS HWAS0000991753TR 279.3GB Member Disk
1 ST3300656SS 37VN00009846RAJ1 279.3GB Member Disk
Select the disks that should be reset.
Resetting RAID disk will remove its RAID structures
and revert it to a non-RAID disk.
[ ]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
[ RESET RAID DATA ]
WARNING: Resetting a disk causes all data on the disk to be lost.
(This does not apply to Recovery volumes)
5-9
Z11PA-U12 Series
Select a destination disk with the same size as the original hard disk.
5.2.5 Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays
the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array
with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. During POST, press <Ctrl>+<I> at the prompt to enter the Intel Rapid Storage
Technology option ROM utility.
2. If there is a non-RAID SATA Hard Disk available, the utility will prompt you to rebuild
the RAID. Press the up/down arrow keys to select the destination disk then Press
<Enter> to start the rebuilding process, or press <ESC> to exit.
5.2.4 Exiting the Intel® Rapid Storage Technology enterprise
SATA/SSATA Option ROM utility
To exit the utility:
1. From the utility main menu, select 4. Exit then press <Enter>.
2. Press <Y> to exit or press <N> to return to the utility main menu.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model Serial # Size
X XXXXXXXXXXX XXXXXXXX XXX.GB
“Degraded” volume and disk available for rebuilding detected. Selectign
a disk initiates a rebuild. Rebuild completes in the operating system.
[ ]-Previous/Next [ENTER]-Select [ESC]-Exit
[ DEGRADED VOLUME DETECTED ]
Are you sure you want to exit? (Y/N):
[ CONFIRM EXIT ]
5-10 Chapter 5: RAID Conguration
3. The utility immediately starts rebuilding after the disk is selected. When done, the
status of the degraded RAID volume is changed to “Rebuild”.
4. Press <Esc> to exit Intel Rapid Storage Technology and reboot the system.
5. Select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or
click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Storage
Manager utility.
6. From the View menu, select Advanced Mode to display the details of the Intel Rapid
Storage Console.
7. From the Volumes view option, select RAID volume to view the rebuilding status.
When nished, the status is changed to “Normal”.
Rebuilding the RAID with a new hard disk
If any of the SATA hard disk drives included in the RAID array failed, the system displays the
status of the RAID volume as “Degraded” during POST. You may replace the disk drive and
rebuild the RAID array.
To rebuild the RAID with a new hard disk:
1. Remove the failed SATA hard disk and install a new SATA hard disk of the same
specication into the same SATA Port.
Select a destination disk with the same size as the original hard disk.
2. Reboot the system then follow the steps in section Rebuilding the RAID with other
non-RAID disk.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes: *=Data is Encrypted
ID Name Level1 Strip Size Status Bootable
1 Volume0 RAID1(Mirror) N/A 149.0GB Rebuild Yes
Physical Devices:
Port Drive Model Serial # Size Type/Status(Vol ID)
1 ST3160812AS 9LS0F4HL 149.0GB Member Disk(0)
2 ST3160812AS 3LS0JYL8 149.0GB Member Disk(0)
Volumes with “Rebuild” status will be rebuilt within the operating system.
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
5-11
Z11PA-U12 Series
5.2.6 Setting the Boot array in the BIOS Setup Utility
You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-
RAID using the Intel® Rapid Storage Technology enterprise SATA Option ROM utililty.
To set the boot array in the BIOS:
Set at least one of the arrays bootable to boot from the hard disk.
1. Reboot the system and press <Del> to enter the BIOS setup utility during POST.
2. Go to the Boot menu and select the boot option priority.
3. Use up/down arrow keys to select the boot priority and press <Enter>. See the Boot
menu section of Chapter 4 for more details.
4. From the Exit menu, select Save Changes & Exit, then press <Enter>.
5. When the conrmation window appears, select Yes, then press <Enter>.
5-12 Chapter 5: RAID Conguration
5.3 Intel® Rapid Storage Technology enterprise
(Windows)
The Intel® Rapid Storage Technology enterprise allows you to create RAID 0, RAID 1, RAID
10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the
Serial ATA connectors supported by the Southbridge.
You can click Rescan to re-scan any attached hard disks.
1. Turn on the system and go to the windows desktop.
2. Click the Intel® Rapid Storage Technology enterprise icon to display the main menu.
Your storage system is congured for data protection, increased performance and
optimal data storage capacity. You can create additional volumes to further optimize
your storage system.
To enter the Intel® Rapid Storage Technology enterprise utility under Windows operating
system:
You need to manually install the Intel® Rapid Storage Technology enterprise utility on a
Windows® operating system. Please refer to the installation instructions in Chapter 6.
5-13
Z11PA-U12 Series
5.3.1 Creating a RAID set
To create a RAID set:
1. From the utility main menu, select Create Volume and select volume type.
2. Click Next.
3. Enter a name for the RAID set, then select the array disks.
4. Select Volume Size tab, you can drag the bar to decide the volume size.
5. Click Next.
• If you do not want to keep the data on one of the selected disks, select NO when
prompted.
• If you want to Enable volume write-back cache or Initialize volume, click
Advanced.
5-14 Chapter 5: RAID Conguration
6. Conrm the volume creation, than click Create Volume to continue.
This process could take a while depending on the number and size of the disks. You can
continue using other applications during this time.
7. Wait until the process is completed, then click OK when prompted.
You still need to partition your new volume using Windows Disk Management before
adding any data.
The RAID set is displayed in the Volumes list and you can change the settings in
Volume Properties.
5-15
Z11PA-U12 Series
5.3.2 Changing a Volume Type
To change the volume type in Volume Properties:
1. Click the SATA array items you want to change in Volumes eld.
2. From the Volume Properties eld, select Type:RAID 1 Change type.
We recommend a lower stripe size for server systems, and a higher stripe size for
multimedia computer systems used mainly for audio and video editing.
3. You can change the Name, Select the new volume type, and Select additional
disks to include in the new volume if needed.
4. Select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only), and click
OK. The available stripe size values range from 4 KB to 128 KB. The following are
typical values:
RAID 0: 128KB
RAID 10: 64KB
RAID 5: 64KB
5-16 Chapter 5: RAID Conguration
5.3.3 Deleting a volume
Be cautious when deleting a volume. You will lose all data on the hard disk drives.Before
you proceed, ensure that you back up all your important data from your hard drives.
To delete a volume:
1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes eld
you want to delete.
3. Click Yes to delete the volume and return to the utility main menu, or click No to return
to the main menu.
2. Select Delete volume in Volume Properties eld. The following screen appears.
5-17
Z11PA-U12 Series
5.3.4 Preferences
System Preferences
Allow you to set to show the notication area icon and show system information, warning, or
errors here.
E-Mail Preferences
Allow you to set to sent e-mail of the following events:
• Storage system information
• Storage system warnings
• Storage system errors
5-18 Chapter 5: RAID Conguration
5.4 Intel® Virtual Raid on CPU in BIOS
This feature requires a KEY module to enable CPU RAID functions with Intel® CPU RSTe.
• The KEY module is purchased separately.
• Refer to section 2.8.2 Internal connectors for the location of the VROC_HW_KEY
connector.
Due to hardware design, your motherboard does not support CPU RAID congurations as
OS drives.
To enter the Intel® Virtual Raid on CPU in BIOS:
1. Enter the BIOS Setup during POST.
2. Go to the Advanced menu > Intel(R) Virtual Raid on CPU > All Intel VMD
Controllers then press <Enter> to display the Intel® Virtual Raid on CPU menu.
Refer to Chapter 4 for details on entering and navigating through the BIOS Setup.
Due to chipset limitation, when SATA ports are set to RAID mode, all SATA ports run at
RAID mode together.
5-19
Z11PA-U12 Series
5.4.1 Creating a RAID set
To create a RAID set:
1. From the Intel® Virtual Raid on CPU menu, select Create RAID Volume and press
<Enter>. The following screen appears:
2. When the Name item is selected, enter a name for the RAID set and press <Enter>.
3. When the RAID Level item is selected, press <Enter> to select the RAID level to
create, and then press <Enter>.
4. When the Enable RAID spanned over VMD Controllers item is selected, press
<Enter> and select X to enable this function.
5. Under Select Disks, press <Enter> and select X for the disks you want to include in the
RAID set.
6. When the Strip Size item is selected, press <Enter> to select strip size for the RAID
array (for RAID 0, 10 and 5 only), and then press <Enter>. The available strip size
values range from 4 KB to 128 KB. The following are typical values:
- RAID 0: 128 KB
- RAID 10: 64 KB
- RAID 5: 64 KB
We recommend a lower strip size for server systems, and a higher strip size for multimedia
computer systems used mainly for audio and video editing.
5-20 Chapter 5: RAID Conguration
7. When the Capacity (MB) item is selected, enter the RAID volume capacity that you
want and press <Enter>. The default value indicates the maximum allowed capacity.
8. When the Create Volume item is selected, press <Enter> to create the RAID volume
and return to the Intel® Rapid Storage Technology menu.
5-21
Z11PA-U12 Series
2. When the Delete item is selected, press <Enter>, then select Yes to delete the RAID
volume and return to the Intel® Virtual Raid on CPU menu, or select No to cancel.
5.4.2 Deleting a RAID set
Be cautious when deleting a RAID set. You will lose all data on the hard disk drives when
you delete a RAID set.
To delete a RAID set:
1. From the Intel® Virtual Raid on CPU menu, select the RAID volume you want to delete
and press <Enter>. The following screen appears:
5-22 Chapter 5: RAID Conguration
5.4.3 Installing the RAID controller driver during Windows®
10 OS installation
This part provides the instructions on how to install the RAID controller drivers during OS
installation.
To install the RAID controller driver when installing Windows® 10 OS:
1. Boot the computer using the Windows® 10 OS installation disc. Follow the screen
instructions to start installing Windows® 10.
2. When prompted to choose a type of installation, click Custom: Install Windows only
(advanced).
3. Click Load Driver.
5-23
Z11PA-U12 Series
4. A message appears, reminding you to insert the installation media containing the driver
of the RAID controller driver. If you have only one optical drive installed in your system,
eject the Windows OS installation disc and replace with the motherboard Support DVD
into the optical drive. Click Browse to continue.
5. Locate the driver in the corresponding folder of the support DVD then click OK to
continue.
6. Select the RAID controller driver you need from the list and click Next.
7. When the system nishes loading the RAID driver, replace the motherboard Support
DVD with the Windows Server installation disc. Select the drive to install Windows and
click Next.
8. Setup then proceeds with the OS installation. Follow screen instructions to continue.
5-24 Chapter 5: RAID Conguration
6
Driver Installation
Chapter 6: Driver Installation
This chapter provides the instructions for installing the
necessary drivers for different system components in the
Windows® Operating Systems.
6-2 Chapter 6: Driver Installation
6.1 RAID driver installation
After creating the RAID sets for your server system, you are now ready to install an
operating system to the independent hard disk drive or bootable array. This part provides the
instructions on how to install the RAID controller drivers during OS installation.
6.1.1 Creating a USB flash drive with RAID drive
When installing Windows® Server OS, you can load the RAID driver from a USB ash drive.
You can create a USB ash drive with RAID driver in Windows by copying the les from the
support DVD to the USB ash drive.
To copy the RAID driver to a USB ash drive in Windows environment:
1. Place the motherboard support DVD in the optical drive.
2. Connect a USB ash drive to your system.
3. Click on the optical drive to browse the contents of the support DVD.
4. Click
Drivers > C620 INTEL RAID > Windows > Driver and then copy the RAID driver
folder to the USB ash drive.
6.1.2 Installing the RAID controller driver
During Windows® Server 2012 R2 OS installation
To install the RAID controller driver when installing Windows® Server 2012 R2 OS:
1. Boot the computer using the Windows® Server 2012 R2 OS installation disc. Follow the
screen instructions to start installing Windows Server 2012 R2.
2. When prompted to choose a type of installation, click Custom: Install Windows only
(advanced).
Z11PA-U12 Series 6-3
3. Click Load Driver.
4. A message appears reminding you to insert the installation media containing the driver of
the RAID controller driver (the installation media can be a CD, DVD, or USB ash drive).
• If you have only one optical drive installed in your system, eject the Windows OS
installation disc and replace with the motherboard Support DVD into the optical
drive.
• Or you may connect a USB ash drive containing the RAID controller driver.
Click Browse to continue.
5. Locate the driver in the corresponding folder of the Support DVD or USB ash drive
and then click OK to continue.
6. Select the RAID controller driver you need from the list and click Next.
6-4 Chapter 6: Driver Installation
7. When the system nishes loading the RAID driver,
• Replace the motherboard Support DVD with the Windows Server installation disc.
• Remove the USB ash drive.
Select the drive to install Windows and click Next.
8. Setup then proceeds with the OS installation. Follow screen instructions to continue.
Z11PA-U12 Series 6-5
6.2 Management applications and utilities installation
When you place the support DVD into the optical drive, the DVD automatically displays the
main screen if Autorun is enabled in your computer. By default, the Drivers tab is displayed.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
6.3 Running the Support DVD
• The contents of the support DVD are subject to change at any time without notice.
Visit the ASUS website (www.asus.com) for the latest updates on software and
utilities.
• The support DVD is supported on Windows® Server 2012 R2 and Windows® Server
2016.
The support DVD that is bundled with your motherboard contains drivers, management
applications, and utilities that you can install to maximize the features of your motherboard.
The main screen of the Support DVD contains the following tabs:
1. Drivers
2. Utilities
3. Manual
4. Contact
The main screen of the Support DVD looks exactly the same on the Windows® Server 2012
R2 and on the Windows® Server 2016 Operating System (OS).
6-6 Chapter 6: Driver Installation
The Drivers Menu shows the available device drivers if the system detects installed devices.
Install the necessary drivers to activate the devices.
6.3.2 Utilities menu tab
The Utilities menu displays the software applications and utilities that the motherboard supports.
6.3.1 Drivers menu tab
Z11PA-U12 Series 6-7
6.3.3 Manual menu
The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter user guide.
You need an internet browser installed in your OS to view the User Guide.
6.3.4 Contact information menu
The Contact menu displays the ASUS contact information, e-mail addresses, and useful links
if you need more information or technical support for your motherboard.
6-8 Chapter 6: Driver Installation
6.4 Intel® chipset device software installation
This section provides the instructions on how to install the Intel® chipset device software on
the system.
You need to manually install the Intel® chipset device software on a Windows operating
system.
To install the Intel® chipset device software:
1. Restart the computer, and then log on with Administrator privileges.
2. Insert the motherboard/system support DVD into the optical drive. The support DVD
automatically displays the Drivers menu if Autorun is enabled in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
3. Click the item Intel® Chipset Device Software from the menu.
4. The
Intel® Chipset Device Software window appears. Click Next to start the
installation.
Z11PA-U12 Series 6-9
5. Read the License Agreement and click Accept to continue the process.
6. Read the Readme File Information and click Install to start the installation process.
7. Click Restart Now to complete the setup process.
6-10 Chapter 6: Driver Installation
5. Click Install Drivers and Software option to begin installation.
6.5 Installing the Intel® I210 Gigabit Adapters driver
This section provides the instructions on how to install the Intel® I210 Gigabits Adapter
Driver on the system.
To install the Intel® I210 Gigabit Adapters Driver on the Windows® operating system:
1. Restart the computer.
2. Log on with Administrator privileges.
3. Insert the motherboard/system support DVD to the optical drive.
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to
locate the le ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run
the support DVD.
4. Click Intel® I350-AM1/I350-AM2/I210 Gigabit Adapters Driver in the Drivers menu of
the main screen to start the installation.
Z11PA-U12 Series 6-11
6. Click Next when the Intel(R) Network Connections Install Wizard window appears.
7. Tick I accept the terms in the license agreement and click Next to continue.
8. From the Setup Options window, click Next to start the installation.
By default, Intel(R) PROSet for Windows Device Manager and Windows PowerShell
Module are ticked.
6-12 Chapter 6: Driver Installation
9. Click Install to start the installation.
10. When the installation is done, press Finish to complete the installation.
Z11PA-U12 Series 6-13
6.7 Intel® Rapid Storage Technology enterprise 5.0
installation
This section provides the instructions on how to install the Intel® Rapid Storage Technology
enterprise 5.0 on the system.
You need to manually install the Intel® Rapid Storage Technology enterprise 5.0 utility on a
Windows® operating system.
To install the Intel® Rapid Storage Technology enterprise 5.0 utility:
1. Restart the computer, and then log on with Administrator privileges.
2. Insert the motherboard/system support DVD into the optical drive, and navigate to the
Utilities menu.
3. Click the Intel® Rapid Storage Technology enterprise to begin installation.
4. The
Intel® Rapid Storage Technology enterprise window appears. Click Next to start
the installation.
6-14 Chapter 6: Driver Installation
5. Read the Warning message and click Next to continue.
6. Read the License Agreement and click Accept to continue the process.
7. Select the destination folder and click Next to continue.
Z11PA-U12 Series 6-15
8. Tick the features that you would like to install and click Next to continue.
9. Click Install to start the installation process.
10. Click Restart Now to complete the setup process.
6-16 Chapter 6: Driver Installation
A
Appendix
This appendix includes additional information that you may
refer to when conguring the motherboard.
Appendix
A-2 Appendix
Z11PA-U12 Series block diagram
Z11PA-U12/10G-2S
Z11PA-U12 Series A-3
Z11PA-U12
A-4 Appendix
Q-Code table
Action PHASE POST CODE TYPE DESCRIPTION
Normal boot
Security Phase
01 Progress First post code(POWER_ON_POST_CODE)
02 Progress Load BSP microcode(MICROCODE_POST_CODE)
03 Progress Set cache as ram for PEI phase(CACHE_ENABLED_POST_CODE)
06 Progress CPU Early init.(CPU_EARLY_INIT_POST_CODE)
04 Progress initializes South bridge for PEI preparation
PEI (Pre-EFI
initialization) phase
10 Progress PEI Core Entry
15 Progress NB initialize before installed memory
19 Progress SB initialize before installed memory
78~00 Progress Wait BMC ready(duration: 120 seconds)
A1 MRC Progress QPI initialization
A3 MRC Progress QPI initialization
A7 MRC Progress QPI initialization
A8 MRC Progress QPI initialization
A9 MRC Progress QPI initialization
AA MRC Progress QPI initialization
AB MRC Progress QPI initialization
AC MRC Progress QPI initialization
AD MRC Progress QPI initialization
AE MRC Progress QPI initialization
AF MRC Progress QPI initialization Complete
2F Progress Memory Init.
B0 MRC Progress Memory Init.
B1 MRC Progress Memory Init.
AF MRC Progress RC Reset if require
B4 MRC Progress Memory Init.
B2 MRC Progress Memory Init.
B3 MRC Progress Memory Init.
B5 MRC Progress Memory Init.
B6 MRC Progress Memory Init.
B7 MRC Progress Memory Init.
B8 MRC Progress Memory Init.
B9 MRC Progress Memory Init.
BA MRC Progress Memory Init.
BB MRC Progress Memory Init.
BC MRC Progress Memory Init.
BF MRC Progress Memory Init. Done
5A MRC Progress Other cong. After RC end
31 Progress Memory already installed
32 Progress CPU Init.
34 Progress CPU Init.
36 Progress CPU Init.
4F Progress DXE Initial Program Load(IPL)
(continued on the next page)
Z11PA-U12 Series A-5
Action PHASE POST CODE TYPE DESCRIPTION
Normal boot
DXE (Driver
Execution
Environment) phase
60 Progress DXE Core Started
61 Progress DXE NVRAM Init.
62 Progress SB run-time init.
63 Progress DXE CPU Init
68 Progress NB Init.
69 Progress NB Init.
6A Progress NB Init.
70 Progress SB Init.
71 Progress SB Init.
72 Progress SB Init.
78 Progress ACPI Init.
79 Progress CSM Init.
BDS (Boot Device
Selection) phase
90 Progress BDS started
91 Progress Connect device event
92 Progress PCI Bus Enumeration.
93 Progress PCI Bus Enumeration.
94 Progress PCI Bus Enumeration.
95 Progress PCI Bus Enumeration.
96 Progress PCI Bus Enumeration.
97 Progress Console outout connect event
98 Progress Console input connect event
99 Progress AMI Super IO start
9A Progress AMI USB Driver Init.
9B Progress AMI USB Driver Init.
9C Progress AMI USB Driver Init.
9D Progress AMI USB Driver Init.
b2 Progress Legacy Option ROM Init.
b3 Progress Reset system
b4 Progress USB hotplug
b6 Progress NVRAM clean up
b7 Progress NVRAM conguration reset
A0 Progress IDE, AHCI Init.
A1 Progress IDE, AHCI Init.
A2 Progress IDE, AHCI Init.
A3 Progress IDE, AHCI Init.
A8 Progress BIOS Setup Utility password verify
A9 Progress BIOS Setup Utility start
AB Progress BIOS Setup Utility input wait
AD Progress Ready to boot event
AE Progress Legacy boot event
Operating system
phase
AA Progress APIC mode
AC Progress PIC mode
Q-Code table
A-6 Appendix
Română ASUSTeK Computer Inc. declară că acest dispozitiv se conformează
cerinţelor esenţiale şi altor prevederi relevante ale directivelor conexe. Textul
complet al declaraţiei de conformitate a Uniunii Europene se găseşte la:
www.asus.com/support
Srpski ASUSTeK Computer Inc. ovim izjavljuje da je ovaj uređaj u saglasnosti
sa osnovnim zahtevima i drugim relevantnim odredbama povezanih
Direktiva. Pun tekst EU deklaracije o usaglašenosti je dostupan da adresi:
www.asus.com/support
Slovensky Spoločnosť ASUSTeK Computer Inc. týmto vyhlasuje, že toto
zariadenie vyhovuje základným požiadavkám a ostatým príslušným
ustanoveniam príslušných smerníc. Celý text vyhlásenia o zhode pre štáty EÚ
je dostupný na adrese: www.asus.com/support
Slovenščina ASUSTeK Computer Inc. izjavlja, da je ta naprava skladna z
bistvenimi zahtevami in drugimi ustreznimi določbami povezanih direktiv.
Celotno besedilo EU-izjave o skladnosti je na voljo na spletnem mestu:
www.asus.com/support
Español Por la presente, ASUSTeK Computer Inc. declara que este dispositivo
cumple los requisitos básicos y otras disposiciones pertinentes de las
directivas relacionadas. El texto completo de la declaración de la UE de
conformidad está disponible en: www.asus.com/support
Svenska ASUSTeK Computer Inc. förklarar härmed att denna
enhet överensstämmer med de grundläggande kraven och andra
relevanta föreskrifter i relaterade direktiv. Fulltext av EU-försäkran om
överensstämmelse nns på: www.asus.com/support
Українська ASUSTeK Computer Inc. заявляє, що цей пристрій відповідає
основним вимогам та іншим відповідним положенням відповідних
Директив. Повний текст декларації відповідності стандартам ЄС
доступний на: www.asus.com/support
Türkçe AsusTek Computer Inc., bu aygıtın temel gereksinimlerle ve ilişkili
Yönergelerin diğer ilgili koşullarıyla uyumlu olduğunu beyan eder. AB
uygunluk bildiriminin tam metni şu adreste bulunabilir:
www.asus.com/support
Bosanski ASUSTeK Computer Inc. ovim izjavljuje da je ovaj uređaj usklađen
sa bitnim zahtjevima i ostalim odgovarajućim odredbama vezanih direktiva.
Cijeli tekst EU izjave o usklađenosti dostupan je na: www.asus.com/support
English ASUSTeK Computer Inc. hereby declares that this device is in
compliance with the essential requirements and other relevant provisions of
related Directives. Full text of EU declaration of conformity is available at:
www.asus.com/support
Français AsusTek Computer Inc. déclare par la présente que cet appareil est
conforme aux critères essentiels et autres clauses pertinentes des directives
concernées. La déclaration de conformité de l’UE peut être téléchargée à
partir du site Internet suivant : www.asus.com/support
Deutsch ASUSTeK Computer Inc. erklärt hiermit, dass dieses Gerät mit
den wesentlichen Anforderungen und anderen relevanten Bestimmungen
der zugehörigen Richtlinien übereinstimmt. Der gesamte Text der EU-
Konformitätserklärung ist verfügbar unter: www.asus.com/support
Italiano ASUSTeK Computer Inc. con la presente dichiara che questo
dispositivo è conforme ai requisiti essenziali e alle altre disposizioni pertinenti
con le direttive correlate. Il testo completo della dichiarazione di conformità
UE è disponibile all’indirizzo: www.asus.com/support
Русский Компания ASUS заявляет, что это устройство соответствует
основным требованиям и другим соответствующим условиям
соответствующих директив. Подробную информацию, пожалуйста,
смотрите на www.asus.com/support
Български С настоящото ASUSTeK Computer Inc. декларира, че това
устройство е в съответствие със съществените изисквания и другите
приложими постановления на свързаните директиви. Пълният текст на
декларацията за съответствие на ЕС е достъпна на адрес:
www.asus.com/support
Hrvatski ASUSTeK Computer Inc. ovim izjavljuje da je ovaj uređaj sukladan
s bitnim zahtjevima i ostalim odgovarajućim odredbama vezanih direktiva.
Cijeli tekst EU izjave o sukladnosti dostupan je na: www.asus.com/support
Čeština Společnost ASUSTeK Computer Inc. tímto prohlašuje, že toto
zařízení splňuje základní požadavky a další příslušná ustanovení souvisejících
směrnic. Plné znění prohlášení o shodě EU je k dispozici na adrese:
www.asus.com/support
Dansk ASUSTeK Computer Inc. erklærer hermed, at denne enhed er i
overensstemmelse med hovedkravene og andre relevante bestemmelser i de
relaterede direktiver. Hele EU-overensstemmelseserklæringen kan ndes på:
www.asus.com/support
Nederlands ASUSTeK Computer Inc. verklaart hierbij dat dit apparaat
voldoet aan de essentiële vereisten en andere relevante bepalingen van
de verwante richtlijnen. De volledige tekst van de EU-verklaring van
conformiteit is beschikbaar op: www.asus.com/support
Eesti Käesolevaga kinnitab ASUSTeK Computer Inc, et see seade vastab
asjakohaste direktiivide oluliste nõuetele ja teistele asjassepuutuvatele
sätetele. EL vastavusdeklaratsiooni täielik tekst on saadaval järgmisel
aadressil: www.asus.com/support
Suomi ASUSTeK Computer Inc. ilmoittaa täten, että tämä laite on
asiaankuuluvien direktiivien olennaisten vaatimusten ja muiden tätä
koskevien säädösten mukainen. EU-yhdenmukaisuusilmoituksen koko teksti
on luettavissa osoitteessa: www.asus.com/support
Ελληνικά Με το παρόν, η AsusTek Computer Inc. δηλώνει ότι αυτή η
συσκευή συμμορφώνεται με τις θεμελιώδεις απαιτήσεις και άλλες σχετικές
διατάξεις των Οδηγιών της ΕΕ. Το πλήρες κείμενο της δήλωσης συμβατότητας
είναι διαθέσιμο στη διεύθυνση: www.asus.com/support
Magyar Az ASUSTeK Computer Inc. ezennel kijelenti, hogy ez az eszköz
megfelel a kapcsolódó Irányelvek lényeges követelményeinek és egyéb
vonatkozó rendelkezéseinek. Az EU megfelelőségi nyilatkozat teljes szövege
innen letölthető: www.asus.com/support
Latviski ASUSTeK Computer Inc. ar šo paziņo, ka šī ierīce atbilst saistīto
Direktīvu būtiskajām prasībām un citiem citiem saistošajiem nosacījumiem.
Pilns ES atbilstības paziņojuma teksts pieejams šeit: www.asus.com/support
Lietuvių „ASUSTeK Computer Inc.“ šiuo tvirtina, kad šis įrenginys atitinka
pagrindinius reikalavimus ir kitas svarbias susijusių direktyvų nuostatas. Visą
ES atitikties deklaracijos tekstą galima rasti: www.asus.com/support
Norsk ASUSTeK Computer Inc. erklærer herved at denne enheten er i
samsvar med hovedsaklige krav og andre relevante forskrifter i relaterte
direktiver. Fullstendig tekst for EU-samsvarserklæringen nnes på:
www.asus.com/support
Polski Firma ASUSTeK Computer Inc. niniejszym oświadcza, że
urządzenie to jest zgodne z zasadniczymi wymogami i innymi właściwymi
postanowieniami powiązanych dyrektyw. Pełny tekst deklaracji zgodności UE
jest dostępny pod adresem: www.asus.com/support
Português A ASUSTeK Computer Inc. declara que este dispositivo está em
conformidade com os requisitos essenciais e outras disposições relevantes
das Diretivas relacionadas. Texto integral da declaração da UE disponível em:
www.asus.com/support
Simplified EU Declaration of Conformity
Z11PA-U12 Series A-7
ASUS contact information
ASUSTeK COMPUTER INC.
Address 4F, No. 150, Li-Te Rd., Peitou, Taipei 112, Taiwan
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
Web site https://www.asus.com
Technical Support
Telephone +86-21-38429911
Fax +86-21-58668722 ext: 9101
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=en
ASUSTeK COMPUTER INC. (Taiwan)
Address 4F, No. 150, Li-Te Rd., Peitou, Taipei 112, Taiwan
Telephone +886-2-2894-3447
Fax +886-2-2890-7798
Web site https://www.asus.com/tw/
Technical Support
Telephone +886-2-2894-3447 (0800-093-456)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=zh-tw
ASUSTeK COMPUTER INC. (China)
Address No. 5077, Jindu Road, Minhang District, Shanghai, China
Telephone +86-21-5442-1616
Fax +86-21-5442-0099
Web site https://www.asus.com.cn
Technical Support
Telephone +86-20-2804-7506 (400-620-6655)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=zh-cn
A-8 Appendix
ASUS contact information
ASUS COMPUTER INTERNATIONAL (America)
Address 800 Corporate Way, Fremont, CA 94539, USA
Fax +1-510-608-4555
Web site https://www.asus.com/us/
Technical Support
Support fax +1-812-284-0883
General support +1-812-282-2787
Online support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=en-us
ASUS COMPUTER GmbH (Germany and Austria)
Address Harkort Str. 21-23, 40880 Ratingen, Germany
Fax +49-2102-959911
Web site https://www.asus.com/de/
Technical Support
Telephone +49-1805-010923
Support Fax +49-2102-959911
Online support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=de-de
ASUS Czech Service s.r.o. (Europe)
Address Na Rovince 887, 720 00 Ostrava – Hrabová,
Czech Republic
Telephone +420-596766888
Web site https://www.asus.com/cz/
Technical Support
Telephone +420-596-766-891
Fax +420-596-766-329
E-mail advance.rma.eu@asus.com
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=cs-cz
Z11PA-U12 Series A-9
ASUS contact information
ASUS Holland BV (The Netherlands)
Address Marconistraat 2, 7825GD EMMEN, The Netherlands
Web site https://www.asus.com/nl/
Technical Support
Telephone +31-(0)591-5-70292
Fax +31-(0)591-666853
E-mail advance.rma.eu@asus.com
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=nl-nl
ASUS Polska Sp. z o.o. (Poland)
Address Ul. Postępu 6, 02-676 Warszawa, Poland
Web site https://www.asus.com/pl/
Technical Support
Telephone +48-225718033
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=pl-pl
ASK-Service (Russia and CIS)
Address г.Москва, ул. Орджоникидзе, д.10, Россия
Telephone (495) 640-32-75
Web site https://www.asus.com/ru/
Technical Support
Telephone 008-800-100-ASUS (008-800-100-2787)
Online Support https://www.asus.com/support/Product/ContactUs/Services/
questionform/?lang=ru-ru
A-10 Appendix
DECLARATION OF CONFORMITY
Per FCC Part 2 Section 2. 1077(a)
Responsible Party Name: Asus Computer International
Address: 800 Corporate Way, Fremont, CA 94539.
Phone/Fax No: (510)739-3777/(510)608-4555
hereby declares that the product
Product Name : Motherboard
Model Number : Z11PA-U12/10G-2S
Conforms to the following specifications:
FCC Part 15, Subpart B, Unintentional Radiators
Supplementary Information:
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Representative Person’s Name : Steve Chang / President
Signature :
Date : Sep. 08, 2017
Ver. 170324
Z11PA-U12 Series A-11
DECLARATION OF CONFORMITY
Per FCC Part 2 Section 2. 1077(a)
Responsible Party Name: Asus Computer International
Address: 800 Corporate Way, Fremont, CA 94539.
Phone/Fax No: (510)739-3777/(510)608-4555
hereby declares that the product
Product Name : Motherboard
Model Number : Z11PA-U12
Conforms to the following specifications:
FCC Part 15, Subpart B, Unintentional Radiators
Supplementary Information:
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Representative Person’s Name : Steve Chang / President
Signature :
Date : Sep. 08, 2017
Ver. 170324