Table of Contents
Huawei ESS-96V12-9AHBPVBB02 User Manual
Displayed below is the user manual for ESS-96V12-9AHBPVBB02 by Huawei which is a product in the UPS Batteries category. This manual has pages.
Related Manuals
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
Issue
03
Date
2015-10-12
HUAWEI TECHNOLOGIES CO., LTD.
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
i
Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address:
Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website:
http://e.huawei.com
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
About This Document
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
ii
About This Document
Purpose
This document describes the UPS2000-G-(1 kVA-3 kVA) battery pack in terms of its
appearance, features and specifications, and installation and connections. Unless otherwise
specified, UPS refers to all the models discussed in this document.
Intended Audience
This document is intended for:
Sales engineers
Technical support engineers
System engineers
Hardware installation engineers
Commissioning engineers
Data configuration engineers
Maintenance engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Description
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in equipment damage, data loss,
performance deterioration, or unanticipated results.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
About This Document
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iii
Symbol
Description
NOTICE is used to address practices not related to
personal injury.
Calls attention to important information, best practices
and tips.
NOTE is used to address information not related to
personal injury, equipment damage, and environment
deterioration.
Change History
Changes between document issues are cumulative. The latest document issue contains all the
changes made in previous issues.
Issue 03 (2015-10-12)
Added the 2 kVA UPS battery pack.
Issue 02 (2015-08-10)
Updated the dimensions of battery pack.
Issue 01 (2015-06-25)
This is the first release.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
Contents
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iv
Contents
About This Document .................................................................................................................... ii
1 Precautions ..................................................................................................................................... 1
2 Appearance and Feature .............................................................................................................. 2
2.1 Exterior ......................................................................................................................................................................... 2
2.2 Features ......................................................................................................................................................................... 3
2.2.1 Battery Pack for 1 kVA UPS ...................................................................................................................................... 3
2.2.2 Battery Pack for 2 kVA UPS ...................................................................................................................................... 4
2.2.3 Battery Pack for 3 kVA UPS ...................................................................................................................................... 5
3 Installing the Battery Pack .......................................................................................................... 7
3.1 Unpacking and Checking .............................................................................................................................................. 7
3.2 Preparations .................................................................................................................................................................. 7
3.3 Installation Procedure ................................................................................................................................................... 8
3.3.1 Rack-Mounted Battery Pack ...................................................................................................................................... 8
3.3.2 Tower-mounting a Battery Pack................................................................................................................................. 9
4 Connecting a Battery Pack and a UPS ..................................................................................... 13
4.1 Connecting a Battery Pack and a 1 kVA UPS ............................................................................................................. 13
4.2 Connecting a Battery Pack and a 2 kVA UPS ............................................................................................................. 15
4.3 Connecting a Battery Pack and a 3 kVA UPS ............................................................................................................. 17
A Acronyms and Abbreviations .................................................................................................. 20
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
1 Precautions
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1
1 Precautions
1. Only the professional technical personnel designated by Huawei are allowed to install
and operate the battery pack.
2. Read this document closely before operating the battery pack. Keep this document for
future use.
3. When operating Huawei equipment, you must follow the local laws and regulations.
4. You can modify default parameters only after being approved by Huawei technical
support.
5. To prevent electric shocks, get the tool insulated and wear insulation gloves when
connecting cables.
6. To prevent personal injury, wear protective shoes when moving the battery pack.
7. In case of fire, use a dry powder extinguisher to put out the fire. Using a fluid fire
extinguisher may cause electric shocks.
8. Do not touch uninsulated battery terminals. Otherwise, electric shocks may occur.
9. Using incorrect battery models may cause explosion. Dispose of used batteries by
following instructions specified.
10. Cut off power supply and remove all the metal objects such as the watch, bracelet, or
ring before maintenance.
11. Do not transport the device by holding the mounting brackets, front panel, or protective
cover. When moving a heavy device, follow the product movement regulations, as
shown in Figure 1-1.
Figure 1-1 Product movement regulations
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
2 Appearance and Feature
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2
2 Appearance and Feature
2.1 Exterior
Rack-mounted battery packs can either be rack-mounted or tower-mounted. As shown in
Figure 2-1 and Figure 2-2.
Figure 2-1 Rack-mounted battery pack
Figure 2-2 Tower-mounted battery pack
The standard battery pack for 1 kVA UPS with long backup time is
ESS-36V12-9*2AHBPVBB01. The standard battery pack for 2 kVA UPS with long backup
time is ESS-72V12-9AHBPVBB01. The standard battery pack for 3 kVA UPS with long
backup time is ESS-96V12-9AHBPVBB02. The appearance for 1 kVA UPS, 2 kVA UPS, and
3 kVA UPS are the same. The figures below based on the 3 kVA UPS, as shown in Figure 2-3.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
2 Appearance and Feature
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3
Figure 2-3 Standard battery pack (ESS-96V12-9AHBPVBB02) for 3 kVA UPS and its external
ports
(1) DC port 1
(2) DC port 2
(3) Protection switch
Table 2-1 describes the input and output ports on the battery pack.
Table 2-1 Input and output ports on the battery pack
No.
Port
Port Type
1
DC port 1
SA50 x 2
2
DC port 2
SA50 x 2
2.2 Features
2.2.1 Battery Pack for 1 kVA UPS
Model
ESS-36V12-9*2AHBPVBB01
Interior
Two group of battery strings are embedded, each group with three 9 Ah/12 V DC batteries.
The output voltage of battery pack is 36 V DC.
Basic Features
Color: black
Panel: plastic
Backplane: grey (SECC/SGCC)
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
2 Appearance and Feature
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4
Dimensions (H x W x D): 88 mm x 438 mm x 410 mm
Weight: 17.3 kg
Graphics of the Interior
Figure 2-4 ESS-36V12-9*2AHBPVBB01 battery pack interior
2.2.2 Battery Pack for 2 kVA UPS
Model
ESS-72V12-9AHBPVBB01
Interior
One group of battery strings are embedded, each group with six 9 Ah/12 V DC batteries. The
output voltage of battery pack is 72 V DC.
Basic Features
Color: black
Panel: plastic
Backplane: grey (SECC/SGCC)
Dimensions (H x W x D): 88 mm x 438 mm x 410 mm
Weight: 21.7 kg
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
2 Appearance and Feature
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5
Graphics of the Interior
Figure 2-5 ESS-72V12-9AHBPVBB01 battery pack interior
2.2.3 Battery Pack for 3 kVA UPS
Model
ESS-96V12-9AHBPVBB02
Interior
One group of battery strings are embedded, each group with eight 9 Ah/12 V DC batteries.
The output voltage of battery pack is 96 V DC.
Basic Features
Color: black
Panel: plastic
Backplane: grey (SECC/SGCC)
Dimensions (H x W x D): 88 mm x 438 mm x 510 mm
Weight: 28.9 kg
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
2 Appearance and Feature
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6
Graphics of the Interior
Figure 2-6 ESS-96V12-9AHBPVBB02 battery pack interior
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
3 Installing the Battery Pack
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7
3 Installing the Battery Pack
3.1 Unpacking and Checking
After a battery pack is delivered onsite, unpack it and check as follows:
If any damage is found on the battery pack appearance, contact the carrier immediately.
Check that battery pack bar code (on the rear of the pack, near the wiring port) is
consistent with that specified in the order. If any discrepancy is found, contact local
Huawei office immediately.
Do not transport the battery pack by holding the mounting ears, front panel, or protective
cover.
Remove rings, watches, and other metal objects before you move the battery pack.
3.2 Preparations
Get installation tools insulated to prevent electric shocks.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
3 Installing the Battery Pack
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8
Table 3-1 Tools
Appearance, Specifications, and Name
Multimeter
Phillips screwdriver
(PH2 x 150 mm, PH3
x 250 mm)
Flat-head
screwdriver (2 mm x
80 mm)
Torque screwdriver
Wire stripper
PVC insulation tape
Cotton cloth
Heat shrink tubing
Heat gun
Electrician's knife
Protective gloves
Electrostatic
discharge (ESD)
gloves
Insulation gloves
Hydraulic pliers
Cable tie
N/A
N/A
3.3 Installation Procedure
Rack-mounted battery packs can either be rack-mounted or tower-mounted.
3.3.1 Rack-Mounted Battery Pack
Procedure:
Step 1 Install mounting ears.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
3 Installing the Battery Pack
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9
Step 2 Install the battery pack.
The proposed torque is 3 N•m here.
----End
3.3.2 Tower-mounting a Battery Pack
To tower-mount a battery pack, perform the following steps:
Procedure:
Step 1 Remove the front panel.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
3 Installing the Battery Pack
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10
Step 2 Adjust the battery pack panel as shown in the following figure.
Step 3 Adjust Huawei logo and reinstall the front panel.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
3 Installing the Battery Pack
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
11
Step 4 Assemble the support base and the extended part.
The support base is the accessory of UPS, the accessory of battery pack only is the extended part.
Step 5 Install the battery pack.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
3 Installing the Battery Pack
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
12
The lateral dimensions of UPS and battery pack installed as the above figure is about 300 mm.
Step 6 The installation is complete.
----End
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
4 Connecting a Battery Pack and a UPS
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
13
4 Connecting a Battery Pack and a UPS
4.1 Connecting a Battery Pack and a 1 kVA UPS
Connect the ESS-36V12-9*2AHBPVBB01 battery packs and the 1 kVA UPS using the
battery cable delived with the battery pack, as shown in Figure 4-1.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
4 Connecting a Battery Pack and a UPS
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
14
Figure 4-1 Connection between the ESS-36V12-9*2AHBPVBB01 battery pack and a 1 kVA UPS
ESS-36V12-9*2AHBPVBB01 is allowed a maximum of two groups in parallel.
The battery pack has two output ports, as a parallel state, the same function. If one used to connect
the UPS or battery pack, another can be used to connect an external charger. In the preceding
figures, the unused port on the battery pack on the right can connect to an external charger.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
4 Connecting a Battery Pack and a UPS
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15
Before connecting, please make sure that the breaker of the battery pack is in the OFF state.
4.2 Connecting a Battery Pack and a 2 kVA UPS
Connect the ESS-72V12-9AHBPVBB01 battery packs and the 2 kVA UPS using the battery
cable delived with the battery pack, as shown in Figure 4-2.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
4 Connecting a Battery Pack and a UPS
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
16
Figure 4-2 Connection between the ESS-72V12-9AHBPVBB01 battery pack and a 2 kVA UPS
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
4 Connecting a Battery Pack and a UPS
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
17
ESS-72V12-9AHBPVBB01 is allowed a maximum of four groups in parallel. The text uses two
groups in parallel as an example. If four groups need to be connected, refer to the connection method
of two groups.
The battery pack has two output ports, as a parallel state, the same function. If one used to connect
the UPS or battery pack, another can be used to connect an external charger.
Before connecting, please make sure that the breaker of the battery pack is in the OFF state.
4.3 Connecting a Battery Pack and a 3 kVA UPS
Connect the ESS-96V12-9AHBPVBB02 battery packs and the 3 kVA UPS using the battery
cable delived with the battery pack, as shown in Figure 4-3.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
4 Connecting a Battery Pack and a UPS
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
18
Figure 4-3 Connection between the ESS-96V12-9AHBPVBB02 battery pack and a 3 kVA UPS
ESS-96V12-9AHBPVBB02 is allowed a maximum of four groups in parallel. The text uses two
groups in parallel as an example. If four groups need to be connected, refer to the connection method
of two groups.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
4 Connecting a Battery Pack and a UPS
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
19
The battery pack has two output ports, as a parallel state, the same function. If one used to connect
the UPS or battery pack, another can be used to connect an external charger.
Before connecting, please make sure that the breaker of the battery pack is in the OFF state.
UPS2000-G-(1 kVA-3 kVA) Battery Pack
Quick Installation Guide
A Acronyms and Abbreviations
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
20
A Acronyms and Abbreviations
U
UPS
uninterruptible power system