1
The switches must be installed in a clean, dry, and well ventilated environment with stable temperature. The
installation site must be free from leaking or dripping water, heavy dew, and humidity.
Take dustproof measures in the site. Dust will cause electrostatic charges on the chassis and affect connections
of metal connectors and joints. This shortens service life of the switches and may cause failures of the switches.
The temperature and humidity in the site must be within the operating temperature and humidity ranges
required for the switch. (operating temperature: 0°C to 45°C; relative humidity: 5%RH to 95%RH,
noncondensing). If the relative humidity exceeds 70%, use dehumidifiers or air conditioners with
dehumidification features.
There should be sufficient space around a switch for heat dissipation. Leave at least 50 mm clearance at two
sides and rear of each chassis.
Chassis (with the product model on the nameplate)
Power cable
Installation accessory package:
1 Packing List
- Open Source Software Notice
- Warranty Card
- Mounting brackets
- Rubber pads
- Chassis ground cable
- Quick Start Guide
- Screws
- Dust plugs
The numbers and types of items in the installation accessory package differ for different product models.
Some switches have dust plugs delivered with them. Keep the dust plugs properly and use them to protect idle optical ports.
NOTE
NOTE
The installation, cable connection, and login methods for S600-E series switches are similar. This document uses S628-E as an
example.
Figures in the document are for reference only and may be different from actual devices.
2 Safety Guidelines
To ensure personal and equipment safety, observe all the safety precautions on the equipment and in this
document. WARNING and CAUTION items do not cover all the safety precautions and are only supplementary
to the safety precautions.
Follow all the safety precautions and instructions provided by Huawei. The safety precautions outlined in this
document are only requirements of Huawei and do not include general safety requirements. Huawei is not
liable for any consequence that results from violation of regulations pertaining to safe operations or safety
codes pertaining to design, production, and equipment use.
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
Take ESD protection measures during equipment installation and maintenance. For example, wear ESD gloves or an ESD wrist
strap.
During equipment transport and installation, prevent the equipment from colliding with objects like doors, walls, or shelves.
Do not touch unpainted metal surfaces of equipment components with wet or contaminated gloves.
Do not place other objects on the chassis.
CAUTION
3 Site Environment
2
The S600-E series switches use forced or natural heat dissipation mode. If multiple switches are installed in a
cabinet/rack, leave at least 1 U distance between each two switches (1 U = 44.45 mm). This distance is
recommended for switches using forced heat dissipation, and is required for switches using natural heat
dissipation.
Grounding the switch helps protect it from lightning, electromagnetic interference, and electrostatic discharge,
and is the prerequisite for a PoE switch to provide power for a PD.
M4
1 2
Port side faces down
Expansion bolt
4 Installing the Chassis
Scenario 1: Desk Mounting
Scenario 2: Wall Mounting
Do not stack fanless switches on top of or closely next to each other.
S600-E series switches provide a security slot ( ) near the panel on a side of the chassis. You can install a
security lock (separately purchased) in this slot to protect the switch against theft.
Before You Start
Installation Procedure
Attach four rubber pads to the bottom.
Place the chassis on a desk.
Use M4 screws to fix the mounting brackets on
both sides close to the port side.
Use a hammer drill with φ8 drill bit to drill holes
on the wall, and fix the switch on the wall with
expansion bolts.
Connect the ground cable to the ground point.
Step 1
Step 2
Step 1
Step 2
Step 3
(Optional) Install a security lock.
Connect the ground cable to the ground point.
Step 3
Step 4
1
3
2
Before drilling holes in a wall, make sure there are no power cables in the wall to avoid electric shock.
The port-side panel must face down to protect the ports from water damage.
Ensure that there are no flammable or explosive materials near the switch and no obstructions within 100 mm
around the switch.
The expansion bolts need to be purchased separately.
Before You Start
3
M4 screw
1U
M6 screw
3
4
5
1U
2
Scenario 3: Cabinet/Rack Mounting
Installation Procedure
Secure mounting brackets to the chassis with M4 screws.Step 1
Install four floating nuts on the front mounting rails, two on each side. Leave a distance of 1 U between
the two floating nuts on each mounting rail.
Hold bottom of the chassis and move the chassis into the cabinet/rack.
Use M6 screws to secure the chassis onto the cabinet/rack.
Connect the ground cable. Connect the M4 lug (with a smaller hole) to the ground point at the rear of
chassis and the M6 lug (with a larger hole) to the ground point on the cabinet/rack.
Step 2
Step 3
Step 4
Step 5
Before You Start
An S600-E series chassis is 1 U high, and its width is standard. It can be installed in a standard 19 inch
cabinet/rack.
The cabinet/rack must have reliable ground points to ground the switch.
A separately purchased non-standard cabinet/rack must have sufficient space for chassis installation.
Install a mounting bracket on the other side in the same way.
The captive screws and M6 screws are not delivered with the switch and need to be separately purchased if
needed.
The length of three adjacent mounting holes may not be 1 U. Observe the scale ticks on the mounting rails
when installing floating nuts.
~100-240V;50/60Hz;0.8A
4 56
S628-E
1G PNP
25 26 27 28
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
21
22 23 24
MODE
HUAWEI
STCK
SPED
STAT
SYS
PWR
CONSOLE
132
A network cable connects to an Ethernet electrical port
to send and receive data services.
A newly delivered device is configured locally through
the console port.
Before connecting an optical fiber, check whether the
fiber connector is contaminated. If so, use an air-laid
cotton or a fiber cleaner to clean the fiber connector.
Network cable
Console cable
Optical fiber
No.
1
2
3
Item Connect To Remarks
Switch or computer
Upstream network device
Operation terminal
(usually a PC)
Ground cable
AC power cable
M4 lug: to the chassis
M6 lug: to the protection ground
External power source
-
4
5
6
M4 lug: the end with a smaller hole.
M6 lug: the end with a larger hole.
Use an AC power cable complying to the local
standards.
The AC terminal locking latch is not delivered
with the switch.
Jack reserved for
AC terminal locking latch
Power cables and network cables laid indoors or buried underground, and cannot be routed aerially outdoors.
Power cables must be more than 10 cm away from signal cables.
The bend radius of an optical fiber must be 20 times larger than its diameter (generally no less than 40 mm).
CAUTION
5 Connecting Cables
WARNING
Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eye protection.
Do not install power cables while the power is on.
Do not turn on the power until you have finished installing the chassis and connecting cables.
4
6.1 Using the Web Management System for the First Login
6 Logging In to the Switch for the First Time
If you do not save the configuration in 10 minutes after entering the initial configuration mode, the system will
exist from this mode and restore the factory settings.
If the web pages cannot be displayed normally, your web browser may need an upgrade. For details about the
web browser requirements, see the Web-based Configuration Guide of the switch.
The login page may differ slightly in different versions.
Before You Start
Connect your computer to any Ethernet port of the switch using an Ethernet cable.
Hold down the MODE button for over 6s, when all mode indicators turn green, the switch has entered the
initial configuration mode. In this mode, the IP address of the switch is set to 192.168.1.253/24, and the
admin user level is set to 15 automatically.
Configure an IP address for the computer, which is in the same network segment as the default IP address
of the switch.
Start the web browser on the computer, enter https://192.168.1.253 in the address box, and press Enter to
display the initial login page. Enter the default user name admin and default password admin@huawei.com
and select the language on the login page. Then click GO or press Enter.
Step 1
Step 2
Step 3
Step 4
Login Procedure
Configure the switch. The web-based configuration page provides basic and optional configuration items.
The basic configuration enables you to log in to the switch using the web management system, and the
optional configuration enables you to log in to the switch using Telnet or STelnet. Only parameters for the
basic configuration are described below. For details about the optional configuration and more information
about the product, see the Configuration Guide for your switch on the Huawei support website.
Step 5
5
Configuration Item
Management IP Address
Mask
Old Password
WEB User Password
Confirm Password
WEB User Level
Description
Mandatory. Enter the management IP address of the switch, in dotted decimal notation.
Mandatory. Select a subnet mask from the drop-down list box.
Mandatory. Enter the old password for the default web user.
Mandatory. Enter a new password for the default web user.
To ensure password strength, the password must contain at least two types of the following:
lowercase letters, uppercase letters, digits, and special characters (such as ! $ # %), and cannot
contain any space or single quotation mark.
Mandatory. Enter the new password again.
Optional. Select a user level from the drop-down list box. The user of level 3 or higher has
management rights.
Click Apply to save the configuration. When you exit from the initial login page, either of the following
situations will occur depending on the management IP address you configured:
Step 6
If the management IP address is in the same network segment as 192.168.1.253/24, the system jumps to the web login
page directly.
If the management IP address is not in the same network segment as 192.168.1.253/24, you cannot log in to the
switch again using the web management system. You need to configure another IP address for your computer to make
the computer and switch reachable from each other.
The Quick Config function has been added to the web EasyOperation edition since V200R010. You can quickly finish
the configurations of VLAN isolation and interconnection by selecting the Switching and Routing options.
Now, you can log in to the switch using the web management system, Telnet, or STelnet to maintain the switch.
6.2 Using the Console Port for the First Login
The console cable is not delivered with the switch and needs to be separately purchased if needed.
The display information may differ on different product models.
Install third-party terminal simulation software on the PC by referring to user manual or online help.
Before You Start
Use a console cable to connect the switch to a PC.
Start the terminal simulation software, create a connection, select a serial port, and set communication
parameters in consistent with the default configuration of the switch's console port, as listed below:
Step 1
Step 2
Login Procedure
Transmission rate: 9600
Data bit (B): 8
Parity bit: None
Stop bit (S): 1
Flow control mode: None
6
You can run commands to configure the device. Enter a question mark (?) whenever you need help. For more
information, see the Configuration Guide for your switch on the Huawei support website.
Press Enter in subsequent steps until the following information is displayed on the terminal simulation
software, and then enter a password. The default user name for the first login is admin and the default
password is admin@huawei.com. You must change the password after login.
Step 3
Login authentication
Username:admin
Password:
Warning: The default password poses security risks.
The password needs to be changed. Change now? [Y/N]: y
Please enter old password:
Please enter new password:
Please confirm new password:
The password has been changed successfully
<HUAWEI>
The password entered in interactive mode is not displayed on the screen.
If you do not change the authentication mode and password after entering the user view, the authentication password
used for next login is the one configured during the first login.
Log in to Huawei enterprise technical support website
(http://support.huawei.com/enterprise), and select a specific product model and version to
find its documentation.
Log in to Huawei enterprise support community (http://support.huawei.com/ecommunity)
and post your questions in the community.
7 Obtaining Product Documentation and Technical Support
Huawei Enterprise
Technical Support
7
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
No part of this document may be reproduced or transmitted in
any form or by any means without prior written consent of
Huawei Technologies Co., Ltd.
and other Huawei trademarks are trademarks of
Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned
in this document are the property of their
respective holders.
Supplier’s Declaration of Conformity (SDoC)
Unique Identifier: trade name: HUAWEI; product name: Switch;
model number: S600-E
Responsible Party- U.S. Contact Information
Huawei Technologies USA Inc.
5700 Tennyson Parkway, Suite 500
Plano, Texas 75024
Main: 214-919-6000 / TAC Hotline: 877-448-2934
FCC Compliance Statement ( for products subject to Part 15)
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause
undesired operation.
Trademarks and Permissions
Qualification Card
PASS