Huawei 2288H V5 Rack Server User Manual
Displayed below is the user manual for 2288H V5 Rack Server by Huawei which is a product in the Server Barebones category. This manual has pages.
Related Manuals
HUAWEI TECHNOLOGIES CO., LTD.
Huawei FusionServer
V5 Rack Server
Boundless Computing
Inspire an Intelligent Digital World
Huawei FusionServer
1288H V5 Server
1288H V5 (4-drive) 1288H V5 (8-drive) 1288H V5 (10-drive)
| High-Density Deployment with Lower OPEX |
• 2 Intel® Xeon® Scalable processors in 1U space, with 24 DDR4 DIMMs
• Up to 4 3.5-inch or 10 2.5-inch hard drives for local storage, or 4/8 NVMe SSDs
• 2 10GE and 2 GE LAN on motherboard (LOM) ports, and 5 PCIe expansion slots
• Leverages intelligent energy saving to improve performance per watt by 16%; combines
intelligent management features to enable up to 93% accuracy for fault locating
Delivers high computing density, which
is especially suitable for scenarios such
as virtualization, high-performance
computing (HPC), and big data analytics.
Superior Performance, Ultra-high Density
•Supports 2 Intel® Xeon® Scalable Processors in a 1U space. Its Ultra Path Interconnect (UPI) bus supports rates of up to 10.4 GT/s,
and a single CPU supports up to 28 cores. The server supports the Intel® Turbo Boost, hyper-threading, and Advanced Vector
Extensions (AVX-512). A single processor delivers up to 65% higher compute power than the previous-generation processor.
•Provides 24 DDR4 DIMM slots, and delivers memory speeds of up to 2,666 MT/s. This is ideal for application scenarios that
require large-capacity memory.
•Supports heterogeneous computing acceleration, congurable with 2 single-slot half-height half-length (HHHL) GPU or FPGA
accelerator cards.
•Supports two GE and two 10GE LAN on motherboard (LOM) ports, meeting networking requirements of 98% scenarios with
streamlined conguration.
Smart Power Saving and Better Energy Efciency
•Leverages patented Dynamic Energy Management Technology (DEMT), and multiple power-saving measures such as
component hibernation, proportional-integral-derivative (PID) algorithm based fan speed tuning, and active-standby power
supplies, driving down overall equipment power consumption by up to 16% without compromising workload performance.
•Supports 80 Plus® Titanium power supply units (PSUs), with up to 96% conversion efciency and compliant with ENERGY
STAR and China Environmental Labelling.
•Supports 550 W, 900 W, 1,200 W, and 1,500 W PSU options, exibly adapting to different power requirements. The 1,200 W
and 1,500 W PSUs support DC and high-voltage DC (HVDC) technologies, enabling better energy utilization.
Unmatched Intelligent Manageability, Integration, and Openness
•Uses patented intelligent Fault Diagnosis & Management (FDM) technology, delivering up to 93% accuracy in diagnosing core
component faults.
•Integrates eSight for smart entire-lifecycle O&M, boosting deployment and O&M efciency.
»Supports batch OS installation, slashing the average OS installation time of each server from hours to minutes.
»Supports automated rmware upgrade, with exible and congurable upgrade policies for different components and drivers.
»Supports stateless computing, allowing for rapid replication of live-network conguration and swift failover.
•Integrates fault diagnosis LEDs on the front panel to display error codes in real time, enabling maintenance personnel to
rapidly locate a fault.
•Provides standardized open interfaces and development guides, facilitating seamless integration with third-party
management software.
Form factor 1U rack server
Processors 1 or 2 Intel® Xeon® Scalable Processors of up to 205 W
Chipset platform Intel C622
Memory 24 DDR4 DIMM slots, up to 2,666 MT/s
Internal storage
Three types of hard drive congurations supported:
• 10 x 2.5-inch hard drives (6–8 NVMe SSDs and 2–4 SAS/SATA HDDs, total number of drives ≤ 10) , which can be:
»0–6 NVMe SSDs + 0–4 SAS/SATA hard drives, or
»0–7 NVMe SSDs + 0–3 SAS/SATA hard drives, or
»0–8 NVMe SSDs + 0–2 SAS/SATA hard drives
• 8 x 2.5-inch SAS/SATA hard drives (the NVMe model supports 4 NVMe SSDs)
• 4 x 3.5-inch SAS/SATA hard drives
Flash storage:
• 2 M.2 SSDs
RAID support
• RAID 0, 1, 10, 5, 50, 6, or 60
• Congured with a supercapacitor for cache power-off protection
• Supports RAID level migration, drive roaming, self-diagnosis, and web-based remote conguration
Network ports LOM: 2 x 10GE + 2 x GE ports
Flexible NIC: 2 x GE, 4 x GE, 2 x 10GE, or 1/2 x 56G FDR IB ports
PCIe expansion Up to 5 PCIe 3.0 slots, including 1 for a RAID controller card and 1 for a exible NIC
Heterogeneous
accelerator cards
2 single-slot HHHL GPU or FPGA heterogeneous accelerator cards
For details, visit http://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Fan modules 7 hot-swappable counter-rotating fan modules with support for N+1 redundancy
Power supply units
2 hot-swappable PSUs with support for 1+1 redundancy and the following conguration options (Note 1):
• 550 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W AC Platinum PSUs
1000 W (input: 100 V to 127 V AC)
1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W 380 V HVDC PSUs (input: 260 V to 400 V DC)
• 1200 W -48 V to -60 V DC PSUs (input: -38.4 V to -72 V DC)
Management
• Provides management features such as fault diagnosis, dynamic energy management technology (DEMT), and hardware security
hardening based on Huawei iBMC chips; provides mainstream interfaces, such as Redsh interfaces, enabling easy integration.
• Optionally congured with the Huawei eSight management software to provide advanced management features such as batch
OS deployment and automated rmware upgrade, enabling automated entire-lifecycle management.
Operating Systems
• Microsoft Windows Server
• Red Hat Enterprise Linux
• SUSE Linux Enterprise Server
• CentOS
• Citrix XenServer
• VMware ESXi
For details, visit http://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Security
• Power-on password
• Administrator password
• Trusted Platform Module (TPM)
• Security front panel
Operating temperature 5ºC to 45ºC (41ºF to 113ºF), compliant with ASHRAE A3 and A4
Certication CE, UL, FCC, CCC, and RoHS
Installation suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) Chassis with 3.5-inch hard drives: 43 mm x 447 mm x 748 mm (1.70 in. x 17.60 in. x 29.45 in.)
Chassis with 2.5-inch hard drives: 43 mm x 447 mm x 708 mm (1.70 in. x 17.60 in. x 27.87 in.)
*Last updated on January 18, 2019Remarks:
Note 1: The Titanium PSU is planned for release in Q1 2019.
Huawei FusionServer
1288H V5 Server
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
THIS DOCUMENT IS FOR INFORMATION PURPOSE ONLY, AND DOES NOT
CONSTITUTE ANY KIND OF WARRANTIES.
Scan for an
electronic copy
Scan to learn more about
Huawei servers
For more information
To learn more about Huawei servers, contact Huawei sales representatives or business partners, or visit:
http://e.huawei.com/en/products/cloud-computing-dc/servers
TheHuaweiFusionServer2288/2288HV5isa2U2-socketrackserverthatsupportsvariouscongurationsandcanbewidelyusedin
scenariossuchascloudcomputingvirtualization,databases,andbigdata.TheservercanbeconguredwithtwoIntel® Xeon® Scalable
processors, 16/241 DDR4 DIMM slots (2666 MT/s), 8/102 PCIe slots, and large-capacity local storage resources.
It incorporates patented technologies such as Dynamic Energy Management Technology (DEMT) and Fault Diagnosis & Management (FDM),
and integrates Huawei's eSight software for entire-lifecycle management, helping customers drive down OPEX and improve ROI.
Huawei FusionServer
2288/2288H V5 Server
|FlexibleCongurationsforDiverseWorkloads|
Supreme Performance with Flexible Congurations
•Supports 2 Intel® Xeon® Scalable processors in a 2U space, with an Ultra Path Interconnect (UPI) bus speed of up to 10.4 GT/
s. Each CPU supports up to 20/283 cores. The server supports the Intel® Turbo Boost, hyper-threading, and Advanced Vector
Extensions (AVX-512). A single processor delivers up to 65% higher compute power than its predecessor.
•Provides 16/24 DDR4 DIMM slots, and delivers memory speeds of up to 2,666 MT/s and memory capacities of up to 2 TB or 3 TB
(with 128 GB DIMMs), making it ideal for application scenarios that require large-capacity memory.
•The 2288H V5 supports heterogeneous computing acceleration. It can be congured with two dual-slot full-height full-length
GPU or FPGA accelerator cards.
•The 2288 V5 supports 16 x 3.5-inch or 27 x 2.5-inch local storage drives. The 2288H V5 supports 20 x 3.5-inch or 31 x 2.5-inch
(4/8/12/24/28 NVMe SSDs) local storage drives.
•The 2288 V5 supports 2 GE LOM ports. The 2288H V5 supports 2 GE and 2 x 10GE LOM ports, meeting the networking
requirements of 98% scenarios with streamlined conguration.
3 For the 2288 V5, a single CPU supports up to 20 computing cores. For the 2288H V5, a single CPU supports up to 28 computing cores.
Smart Power Saving and Better Energy Efciency
•Leverages patented Dynamic Energy Management Technology (DEMT), and multiple power-saving measures such as
component hibernation, proportional-integral-derivative (PID) algorithm based fan speed tuning, and active-standby power
supplies, driving down overall equipment power consumption by up to 16% without compromising workload performance.
•Supports 80 Plus® Titanium power supply units (PSUs), with up to 96% conversion efciency and compliant with ENERGY
STAR and China Environmental Labelling.
•Supports 550 W, 900 W, 1,200 W, and 1,500 W PSU options, exibly adapting to different power requirements. The 1,200 W
and 1,500 W PSUs support DC and high-voltage DC (HVDC) technologies, enabling better energy utilization.
Unmatched Intelligent Manageability, Integration, and Openness
•Uses patented intelligent Fault Diagnosis & Management (FDM) technology, delivering up to 93% accuracy in diagnosing core
component faults.
•Integrates eSight for smart entire-lifecycle O&M, boosting deployment and O&M efciency.
»Supports batch OS installation, slashing the average OS installation time of each server from hours to minutes.
»Supports automated rmware upgrade, with exible and congurable upgrade policies for different components and drivers.
»Supports stateless computing, allowing for rapid replication of live-network conguration and swift failover.
•Integrates a touchscreen LCD panel for fault diagnosis, allowing O&M personnel to quickly locate faults (supported only by
the 2288H V5 8-drive models).
•Provides standardized open interfaces and development guides, facilitating seamless integration with third-party
management software.
2288H V5
(8-drive)
2288 V5
(8-drive)
2288/2288H V5
(12-drive)
2288/2288H V5
(25-drive)
2288H V5
(24-drive)
1 The 2288 V5 supports 16 DIMM slots, and the 2288H V5 supports 24. 2 The 2288 V5 supports 8 PCIe slots, and the 2288H V5 supports 10.
Remarks:
Note 1: The Titanium PSU is planned to release in Q1 2019.
Huawei FusionServer
2288/2288H V5 Server
*Last updated on January 18, 2019
2288 V5 2288H V5
Form factor 2U rack server
Processors 1 or 2 Intel® Xeon® Scalable processors of up to 125 W 1 or 2 Intel® Xeon® Scalable Processors of up to 205 W
Chipset platform Intel C621 Intel C622
Memory 16 DDR4 DIMM slots, up to 2,666 MT/s 24 DDR4 DIMM slots, up to 2,666 MT/s
Internal storage
Hard drive congurations supported include:
• 8 x 2.5-inch SAS/SATA HDDs or SSDs
• 12/16 x 3.5-inch SAS/SATA HDDs
• 27 x 2.5-inch SAS/SATA HDDs or SSDs
NVMe SSD card:
• 4 x NVMe SSD cards
Flash storage:
• 2 M.2 SSDs
Hard drive congurations supported include:
• 8 x 2.5-inch SAS/SATA hard drives
• 12/16/20 x 3.5-inch SAS/SATA hard drives
• 4, 8, 12, 24, or 28 NVMe SSDs
• 31 x 2.5-inch SAS/SATA hard drives
Flash storage:
• 2 M.2 SSDs
RAID support
• RAID 0, 1, 10, 1E, 5, 50, 6, or 60
• Congured with a supercapacitor for cache power-off protection
• Supports RAID level migration, drive roaming, self-diagnosis, and web-based remote conguration
Network ports LOM: 2 GE ports
Flexible NIC: 2 x GE, 4 x GE, 2 x 10GE, or 1/2 x 56G FDR IB ports
LOM: 2 x 10GE + 2 x GE ports
Flexible NIC: 2 x GE, 4 x GE, 2 x 10GE, or 1/2 x 56G FDR IB ports
PCIe expansion Up to 8 PCIe 3.0 slots, including 1 for a RAID controller card and
1 for a exible NIC.
Up to 10 PCIe 3.0 slots, including 1 for a RAID controller card and 1 for
a exible NIC.
Heterogeneous
accelerator cards /
2 dual-slot FHFL GPU or FPGA heterogeneous accelerator cards
For details, visit http://support.huawei.com/onlinetoolsweb/ftca/
indexEn?serise=2.
Fan modules 4 hot-swappable counter-rotating fan modules with support for N+1 redundancy
Power supply units
2 hot-swappable PSUs with support for 1+1 redundancy and
the following conguration options:
• 550 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to
288 V DC)
• 900 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to
288 V DC)
• 1500 W AC Platinum PSUs
1000 W (input: 100 V to 127 V AC)
1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
2 hot-swappable PSUs with support for 1+1 redundancy and the
following conguration options (Note 1):
• 550 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V
to 288 V DC)
• 1500 W AC Platinum PSUs
1000 W (input: 100 V to 127 V AC)
1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W 380 V HVDC PSUs (input: 260 V to 400 V DC)
• 1200 W -48 V to -60 V DC PSUs (input: -38.4 V to -72 V DC)
Management
Provides management features such as fault diagnosis, dynamic energy management technology (DEMT), and hardware security
hardening based on Huawei iBMC chips; provides mainstream interfaces, such as Redsh interfaces, enabling easy integration.
Optionally congured with the Huawei eSight management software to provide advanced management features such as batch OS
deployment and automated rmware upgrade, enabling automated entire-lifecycle management.
Operating
Systems
Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, VMware ESXi
For details, visit http://support.huawei.com/onlinetoolsweb/ftca/indexEn?serise=2.
Security Power-on password, Administrator password, Trusted Platform Module (TPM), Security front panel
Operating
temperature 5ºC to 40ºC (41ºF to 104ºF), compliant with ASHRAE A2 and A3 5ºC to 45ºC (41ºF to 113ºF), compliant with ASHRAE A3 and A4
Certication CCC CE, UL, FCC, CCC, and RoHS
Installation suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions
(H x W x D)
Chassis with 3.5-inch hard drives: 86.1 mm x 447 mm x 748 mm (3.39 in. x 17.60 in. x 29.45 in.)
Chassis with 2.5-inch hard drives: 86.1 mm x 447 mm x 708 mm (3.39 in. x 17.60 in. x 27.87 in.)
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
THIS DOCUMENT IS FOR INFORMATION PURPOSE ONLY, AND DOES NOT
CONSTITUTE ANY KIND OF WARRANTIES.
Scan for an
electronic copy
Scan to learn more about
Huawei servers
For more information
To learn more about Huawei servers, contact Huawei sales representatives or business partners, or visit:
http://e.huawei.com/en/products/cloud-computing-dc/servers
5288 V5
Huawei FusionServer
5288 V5 Server
Ultralarge Capacity, Tiered Storage
•Supports 2 Intel® Xeon® Scalable Processors in a 4U space. Its Ultra Path Interconnect (UPI) bus supports rates of up to 10.4
GT/s, and a single CPU supports up to 28 cores. The server supports Intel® Turbo Boost, hyper-threading, and Advanced Vector
Extensions (AVX-512). A single processor delivers up to 65% higher compute power than the previous-generation processor.
•Provides 24 DDR4 DIMM slots, and delivers memory speeds of up to 2,666 MT/s. This is ideal for application scenarios that
require large-capacity memory.
•Ultra-large storage space with 44 3.5-inch and 4 2.5-inch hard drives (up to 8 NVMe SSDs), ideal for tiered storage of hot,
warm, and cold data.
•Supports two GE and two 10GE LAN on motherboard (LOM) ports, meeting networking requirements of 98% scenarios with
streamlined conguration.
Smart Power Saving and Better Energy Efciency
•Leverages patented DEMT, and multiple power-saving measures such as component hibernation, proportional-integral-
derivative (PID) algorithm based fan speed tuning, and active-standby power supplies, driving down overall equipment power
consumption by up to 16% without compromising workload performance.
•Fitted with 80 Plus® Platinum power supply units (PSUs), up to 94% conversion efciency; complies with ENERGY STAR
standards and has passed the China Energy Conservation and Environmentally-Friendly Certication.
•PSUs with 900 W, 1500 W and more power options to exibly adapt to different power requirements, improving energy utilization.
Unmatched Intelligent Manageability, Integration, and Openness
•Uses patented intelligent Fault Diagnosis & Management (FDM) technology, delivering up to 93% accuracy in diagnosing core
component faults.
•Integrates eSight for smart entire-lifecycle O&M, boosting deployment and O&M efciency.
»Supports batch OS installation, slashing the average OS installation time of each server from hours to minutes.
»Supports automated rmware upgrade, with exible and congurable upgrade policies for different components and drivers.
»Supports stateless computing, allowing for rapid replication of live-network conguration and swift failover.
•Integrates fault diagnosis LEDs to display error codes in real time, enabling maintenance personnel to rapidly locate a fault.
•Provides standardized open interfaces and development guides, facilitating seamless integration with third-party
management software.
| Hybrid Storage Architecture,
Tiered Data Storage |
• 2 Intel® Xeon® Scalable processors in 4U space, with 24 DDR4 DIMMs
• Up to 44 3.5-inch hard drives for local storage, or 4/8 NVMe SSDs
• 2 10GE and 2 GE LOM ports, and 10 PCIe expansion slots
• Leverages intelligent energy saving to improve performance per watt by 16%; combines
intelligent management features to enable up to 93% accuracy for fault locating
Offers ultra-large storage capacities,
which is ideal for hot, warm, and cold
data tiered storage in scenarios such as
Content Delivery Network (CDN), video
cloud, and massive data archiving.
Huawei FusionServer
5288 V5 Server
Form Factor 4U rack server
Processors 1 or 2 Intel® Xeon® Scalable processors of up to 205 W
Chipset Intel C622
Memory 24 DDR4 DIMM slots, up to 2666 MT/s memory speeds
Internal Storage
Front:
• 24 x 3.5-inch SAS/SATA hard drives
Embedded:
• 4 x 3.5-inch SAS/SATA hard drives (Note 1)
Rear:
• 16 x 3.5-inch SAS/SATA hard drives
• 16 x 3.5-inch SAS/SATA hard drives + 4 x 2.5-inch SAS/SATA hard drives or NVMe SSDs
• 14 x 3.5-inch SAS/SATA hard drives (congurable with 4 NVMe SSDs) + 4 x 2.5-inch SAS/SATA hard drives or NVMe SSDs
(This conguration does not support internal hard disk and I/O module 1)
Flash storage:
• Two M.2 SSDs
RAID RAID 0, 1, 5, 50, 6, or 60; optional supercapacitor to protect cache data from power failures; RAID level migration, drive roaming, self-
diagnosis, and web-based remote conguration
Network Ports LAN on motherboard (LOM): 2 x 10GE + 2 x GE ports
Flexible NIC: 2 x GE, 4 x GE, 2 x 10GE, or 1/2 x 56G FDR IB ports
PCIe Expansion Up to 10 PCIe 3.0 slots, including 1 for a RAID controller card and 1 for a exible NIC
Fan Modules 4 hot-swappable counter-rotating fan modules with optional N+1 redundancy
Power Supply
2 hot-swappable PSUs with optional 1+1 redundancy. Supported options include:
• 900 W AC Platinum/Titanium PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 1500 W AC Platinum PSUs
1000 W (input: 100 V to 127 V AC)
1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
Management
• Provides management features such as fault diagnosis, dynamic energy management technology (DEMT), and hardware security
hardening based on Huawei iBMC chips; provides mainstream interfaces, such as Redsh interfaces, enabling easy integration.
• Optionally congured with the Huawei eSight management software to provide advanced management features such as batch OS
deployment and automated rmware upgrade, enabling automated entire-lifecycle management.
Operating Systems Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, CentOS, Citrix XenServer, VMware ESXi
For details, see http://support.huawei.com/onlinetoolsweb/ftca/index?serise=2.
Security
• Power-on password
• Administrator password
• Trusted Platform Module (TPM)
• Security front panel
Operating Temperature 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant)
Certication CE, UL, FCC, CCC, and RoHS
Installation Suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) 175 mm x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.)
*Last updated on January 18, 2019
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
THIS DOCUMENT IS FOR INFORMATION PURPOSE ONLY, AND DOES NOT
CONSTITUTE ANY KIND OF WARRANTIES.
Scan for an
electronic copy
Scan to learn more about
Huawei servers
For more information
To learn more about Huawei servers, contact Huawei sales representatives or business partners, or visit:
http://e.huawei.com/en/products/cloud-computing-dc/servers
Huawei FusionServer
2488/2488H V5 Server
2488/2488H V5
| New Option for Distributed Deployment
withHigherComputingEfciency|
Superior Performance with Higher Efciency
•Supports 4 Intel® Xeon® Scalable Processors (Platinum 8100, Gold 6100, or Gold 5100 series) in a 2U space. Its Ultra Path
Interconnect (UPI) bus supports rates of up to 10.4 GT/s, and a single processor supports up to 28 cores. The server supports
Intel® Turbo Boost, hyper-threading, and Advanced Vector Extensions (AVX-512). A single processor delivers up to 65% higher
compute power than the previous-generation processor.
•Provides 32/48 DDR4 DIMM slots1, and delivers memory speeds of up to 2,666 MT/s, ideal for application scenarios that
require large-capacity memory.
•Supports two GE and two 10GE LAN on motherboard (LOM) ports, meeting networking requirements of 98% scenarios with
streamlined conguration.
•Supports up to 25 2.5-inch local hard drives (congurable with 8 NVMe SSDs).
•One FusionServer 2488/2488H V5 saves up to 32%2 OPEX in the virtualization scenario compared with two traditional 2U 2S servers.
1 The 2488 V5 supports up to 32 DIMMs and 2488H V5 supports 48 DIMMs.
2 Data is derived from Huawei lab tests; actual improvement depends on the real-world scenario.
Smart Power Saving and Better Energy Efciency
•Leverages patented Dynamic Energy Management Technology (DEMT), and multiple power-saving measures such as
component hibernation, proportional-integral-derivative (PID) algorithm based fan speed tuning, and active-standby power
supplies, driving down overall equipment power consumption by up to 16% without compromising workload performance.
•Supports 2,000 W Platinum AC power supply unit (PSU), meeting ultra-high performance requirements; leverages the DC and
high-voltage DC (HVDC) technologies to improve energy utilization.
•PSUs meet the requirements of ENERGY STAR and China Environmental Labelling.
Unmatched Intelligent Manageability, Integration, and Openness
•Uses patented intelligent Fault Diagnosis & Management (FDM) technology, delivering up to 93% accuracy in diagnosing core
component faults.
•Integrates eSight for smart entire-lifecycle O&M, driving a leap in deployment and O&M efciency.
»Supports batch OS installation, slashing the average OS installation time of each server from hours to minutes.
»Supports automated rmware upgrade, with exible and congurable upgrade policies for different components and drivers.
»Supports stateless computing, allowing for rapid replication of live-network conguration and swift failover.
•Integrates a touchscreen LCD panel for fault diagnosis, allowing O&M personnel to quickly locate faults (supported only by
the 2488/2488H V5 8-drive models).
•Integrates fault diagnosis LEDs on the front panel to display error codes in real time, enabling maintenance personnel to
rapidly locate a fault.
•Provides standardized open interfaces and development guides, facilitating seamless integration with third-party
management software.
• 4 Intel® Xeon® Scalable processors in 2U space, with 32/48 DDR4 DIMMs
• Up to 25 2.5-inch hard drives for local storage, or 8 NVMe SSDs
• 2 10GE and 2 GE LOM ports, and 9/11 PCIe expansion slots
• Delivers lower OPEX than 2U 2-socket servers; leverages intelligent energy saving to
improve performance per watt by 16%; combines intelligent management features to
enable up to 93% accuracy for fault locating
Unlockshighcomputingefciencyfor
scenarios such as virtualization, HPC,
database, and SAP HANA in-memory
computing.
2488 V5 2488H V5
Form factor 2U rack server
Processors 2 or 4 Intel® Xeon® Scalable Processors of up to 205 W
Chipset platform Intel C622
Memory 32 DDR4 DIMM slots, up to 2,666 MT/s 48 DDR4 DIMM slots, up to 2,666 MT/s
Internal storage
Supports hot-swappable hard drives with the following
conguration options:
• 8 x 2.5-inch SAS/SATA hard drives
• 25 x 2.5-inch SAS/SATA hard drives
• 8 x 2.5-inch NVMe SSDs and 16 x 2.5-inch SAS/SATA
hard drives
Flash storage:
• 2 M.2 SSDs
Supports hot-swappable hard drives with the following
conguration options:
• 8 x 2.5-inch SAS/SATA hard drives
• 25 x 2.5-inch SAS/SATA hard drives
• 24 x 2.5-inch SAS/SATA hard drives
• 8 x 2.5-inch NVMe SSDs and 16 x 2.5-inch SAS/SATA
hard drives
Flash storage:
• 2 M.2 SSDs
RAID support
• RAID 0, 1, 10, 1E, 5, 50, 6, or 60
• Congured with a supercapacitor for cache power-off protection
• Supports RAID level migration, drive roaming
LOM network ports 2 x GE + 2 x 10GE ports
PCIe expansion Up to 9 PCIe 3.0 slots Up to 11 PCIe 3.0 slots
Fan modules 4 hot-swappable fan modules, providing protection against single-fan failures
Power supply units
2 hot-swappable PSUs, with support for 1+1 redundancy. The following PSUs are supported:
• 2000 W AC Platinum PSUs
1800 W (input: 200 V to 220 V AC, or 192 V to 200 V DC)
2000 W (input: 200 V to 240 V AC, or 200 V to 288 V DC)
• 1500 W AC Platinum PSUs
1000 W (input: 100 V to 127 V AC)
1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
• 900 W AC Platinum PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 1200 W DC PSUs (input: -38.4 V to -72 V DC) (Note1)
Management
• Provides management features such as fault diagnosis, dynamic energy management technology (DEMT), and hardware security
hardening based on Huawei iBMC chips; provides mainstream interfaces, such as Redsh interfaces, enabling easy integration.
• Optionally congured with the Huawei eSight management software to provide advanced management features such as batch OS
deployment and automated rmware upgrade, enabling automated entire-lifecycle management.
Operating Systems
• SUSE Linux Enterprise Server
• Red Hat Enterprise Linux
• Windows Server
• Citrix
• CentOS
• Ubuntu
For details, visit http://support.huawei.com/onlinetoolsweb/ftca/index?serise=2.
Security
• Power-on password
• Administrator password
• Trusted Platform Module (TPM)
• Secure startup
• Security front panel
Operating temperature 5°C to 45°C (41°F to 113°F), compliant with ASHRAE Classes A3 and A4
Certication CE, ENERGY STAR, FCC, CCC, RoHS
Installation suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) 86.1 mm x 447 mm x 748 mm (3.39 in. x 17.60 in. x 29.45 in.)
*Last updated on January 18, 2019
Huawei FusionServer
2488/2488H V5 Server
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
THIS DOCUMENT IS FOR INFORMATION PURPOSE ONLY, AND DOES NOT
CONSTITUTE ANY KIND OF WARRANTIES.
Scan for an
electronic copy
Scan to learn more about
Huawei servers
For more information
To learn more about Huawei servers, contact Huawei sales representatives or business partners, or visit:
http://e.huawei.com/en/products/cloud-computing-dc/servers
Huawei FusionServer
5885H V5 Server
5885H V5
High Efciency, Stability, and Expandability
•Supports four Intel® Xeon® Scalable processors in a 4U space. Its Ultra Path Interconnect (UPI) bus supports a speed of up to
10.4 GT/s, and a single CPU supports up to 28 computing cores. The server supports Intel® Turbo Boost, hyper-threading, and
Advanced Vector Extensions (AVX-512). A single processor delivers up to 65% higher compute performance than the previous-
generation processor.
•48 DDR4 DIMMs, up to 2666 MT/s memory speed, meeting large-capacity memory application requirements.
•15 PCIe slots, providing excellent scalability.
•Two GE and two 10GE LAN on motherboard (LOM) ports with streamlined conguration, meeting networking requirements of 98%
scenarios.
•Supports up to 25 x 2.5-inch local hard drives (congurable with 8 NVMe SSDs).
Smart Power Saving and Better Energy Efciency
•Leverages patented DEMT, and multiple power-saving measures such as component hibernation, proportional-integral-
derivative (PID) algorithm based fan speed tuning, and active-standby power supplies, driving down overall equipment power
consumption by up to 16% without compromising workload performance.
•Fitted with 80 Plus® Platinum power supply units (PSUs), up to 94% conversion efciency; complies with ENERGY STAR
standards and has passed the China Energy Conservation and Environmentally-Friendly Certication.
•PSUs with 900 W, 1200 W, 1500 W, and more power options to exibly adapt to different power requirements, improving
energy utilization
Unmatched Intelligent Manageability, Integration, and Openness
•Uses patented intelligent Fault Diagnosis & Management (FDM) technology, delivering up to 93% accuracy in diagnosing core
component faults.
•Integrates eSight for smart entire-lifecycle O&M, driving a leap in deployment and O&M efciency.
»Supports batch OS installation, slashing the average OS installation time of each server from hours to minutes.
»Supports automated rmware upgrade, with exible and congurable upgrade policies for different components and drivers.
»Supports stateless computing, allowing for rapid replication of live-network conguration and swift failover.
•Integrates a touchscreen LCD panel for fault diagnosis, allowing O&M personnel to quickly locate faults (supported only by
the 5885H V5 8-drive models).
•Integrates fault diagnosis LEDs on the front panel to display error codes in real time, enabling maintenance personnel to
rapidly locate a fault.
•Provides standardized open interfaces and development guides, facilitating seamless integration with third-party
management software.
| Deliver Excellent Performance and
Scalability to Enable Fast and
Stable Mission-Critical Services |
• 4 Intel® Xeon® Scalable processors in 4U space, with 48 DDR4 DIMMs
• Up to 25 2.5-inch hard drives for local storage, or 8 NVMe SSDs
• 2 10GE and 2 GE LOM ports, and 15 PCIe expansion slots
• Leverages intelligent energy saving to improve performance per watt by 16%; combines
intelligent management features to enable up to 93% accuracy for fault locating
Delivers excellent stability and reliability
for scenarios such as virtualization, HPC,
and database.
Form Factor 4U rack server
Processors 2 or 4 Intel® Xeon® Scalable processors of up to 205 W
Chipset Intel C622
Memory 48 DDR4 DIMM slots, up to 2666 MT/s memory speeds
Internal Storage
Supports hot-swappable hard drives with the following conguration options:
• 8 x 2.5-inch SAS/SATA hard drives (front)
• 24 x 2.5-inch SAS/SATA hard drives (front)
• 25 x 2.5-inch SAS/SATA hard drives (front)
• 16 x 2.5-inch SAS/SATA hard drives and 8 x 2.5-inch NVMe SSDs (front)
Flash storage:
• Two M.2 SSDs
RAID RAID 0, 1, 5, 50, 6, or 60; optional supercapacitor to protect cache data from power failures; RAID level migration, drive roaming,
|self-diagnosis, and web-based remote conguration
Network Ports LAN on motherboard (LOM): 2 x 10GE + 2 x GE ports
PCIe Expansion Up to 15 PCIe slots for 15 PCIe 3.0 slots
2 dual-width full-height full-length GPU cards (x16)
Fan Modules 5 hot-swappable counter-rotating fan modules with optional N+1 redundancy
Power Supply
4 hot-swappable PSUs with optional 2+2 redundancy. Supported options include:
• 1500 W AC Platinum PSUs
1000 W (input: 100 V to 127 V AC)
1500 W (input: 200 V to 240 V AC, or 192 V to 288 V DC)
• 900 W AC PSUs (input: 100 V to 240 V AC, or 192 V to 288 V DC)
• 1200 W DC PSUs (input: -38.4 V to -72 V DC) (Note 1)
Management
• Provides management features such as fault diagnosis, dynamic energy management technology (DEMT), and hardware security
hardening based on Huawei iBMC chips; provides mainstream interfaces, such as Redsh interfaces, enabling easy integration.
• Optionally congured with the Huawei eSight management software to provide advanced management features such as batch OS
deployment and automated rmware upgrade, enabling automated entire-lifecycle management.
Operating Systems
• Microsoft Windows Server
• Red Hat Enterprise Linux
• SUSE Linux Enterprise Server
• CentOS
• Citrix XenServer
• VMware ESXi
For details, see http://support.huawei.com/onlinetoolsweb/ftca/index?serise=2.
Security
• Power-on password
• Administrator password
• Trusted Platform Module (TPM)
• Security front panel
Operating Temperature 5ºC to 45ºC (41ºF to 113ºF) (ASHRAE A3 and A4 compliant)
Certication CE, UL, FCC, CCC, and RoHS
Installation Suite L-shaped guide rails, adjustable guide rails, and holding rails
Dimensions (H x W x D) 175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10 in.)
Huawei FusionServer
5885H V5 Server
*Last updated on January 18, 2019
Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.
THIS DOCUMENT IS FOR INFORMATION PURPOSE ONLY, AND DOES NOT
CONSTITUTE ANY KIND OF WARRANTIES.
Scan for an
electronic copy
Scan to learn more about
Huawei servers
For more information
To learn more about Huawei servers, contact Huawei sales representatives or business partners, or visit:
http://e.huawei.com/en/products/cloud-computing-dc/servers
Copyright © Huawei Technologies Co., Ltd. 2019.
All rights reserved.
No part of this document may be reproduced or transmitted in any form or
by any means without prior written consent of Huawei Technologies Co., Ltd.
General Disclaimer
The information in this document may contain predictive statements
including, without limitation, statements regarding the future nancial
and operating results, future product portfolio, new technology, etc. There
are a number of factors that could cause actual results and developments
to differ materially from those expressed or implied in the predictive
statements. Therefore, such information is provided for reference purpose
only and constitutes neither an offer nor an acceptance. Huawei may
change the information at any time without notice.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base
Bantian Longgang
Shenzhen 518129, P.R. China
Tel: +86-755-28780808
www.huawei.com
Trademark Notice
, HUAWEI, and are trademarks or registered trademarks of
Huawei Technologies Co., Ltd.
Other trademarks, product, service and company names mentioned are
the property of their respective owners.
Why Huawei servers?
Huawei is a world-leading server provider
with a broad spectrum of server offerings
including rack, high-density, blade servers
and KunLun Mission Critical Servers.
Huawei is the industry's only vendor that
has the integrated capabilities of server
R&D, manufacture, and delivery. Huawei
servers have been recognized for their
superior quality, rock-solid reliability,
extraordinary performance, ease of
management,energyefciency,and
security. Huawei servers have served over
5,000 customer accounts across various
industries around the globe, including
government,nance,electricpower,
Internet, telecom, energy, transportation,
and education.