MODELS 503723
& 503730
INT-503723/503730-UM-0808-01
Shown: 16-Port , Model 503730
introDuction
Thank you for purchasing the INTELLINET NETWORK SOLUTIONS™ Digital KVM over IP
Switch, Model 503723 (8-Port) or Model 503730 (16-Port).
This switch is the perfect solution for any organization that demands secure and exible local and
remote administration of its critical systems, offering revolutionized remote server management
by combining industry-leading remote control technology with a proven Enterprise-class digital
KVM switch.
The Digital KVM over IP Switch attaches to your local KVM switch and can be used to support
multiple servers and computers from a single console. The maximum number of devices you
can manage depends on the type of local KVM switch you use, and when cascaded can result
in up to 128 computers remotely managed via a LAN or WAN.
Server management is further simplied by an advanced on-screen display menu. In addition,
the Digital KVM over IP Switch provides BIOS-level control and full interaction with the system’s
boot process; its SSL encryption guarantees the safety you expect for your company’s network.
The switch can alert you in case the remote server stops responding by sending out alert
e-mails or by issuing SNMP traps, adding an important layer of security to your installation.
The easy-to-follow instructions in this user manual help make setup and operation quick and
simple, so you’ll also soon be enjoying the benets of these additional features:
• Connects to any PS/2- or USB-based PC, server or KVM switch
• Local console connection (through PS/2 and VGA ports)
• PC port connection via PS/2 and USB
• Simultaneous access from multiple users; no user limitation
• Supports video resolutions up to 1600 x 1200 @ 60 Hz
• Security using full 1024-bit PKI authentication / 256-bit SSL encryption
• Supports LDAP, RADIUS and Active Directory servers
• Win32 viewer and Java viewer for cross-platform compatibility
• Time synchronization by connection to any NTP time server
• Lifetime Warranty
FCC Statement
This equipment has been tested and found to comply with the regulations for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with this guide, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his own
expense.
CE Statement
This is a Class B product in a domestic environment. This product may cause radio interference,
in which case the user may be required to take adequate measures.
NOTE: Some product images have been compressed and some screen images have been
modied to t the format of this user manual.
3
INTRODUCTION
table of contentS
SYSTEM ARCHITECTURE .................................................................................................. 5
LAN/WAN Congurations ............................................................................................. 5
Power Control Conguration ........................................................................................ 6
PPP Conguration ........................................................................................................ 7
HARDWARE ..................................................................................................................... 8
Front Panel.................................................................................................................... 8
Rear Panel .................................................................................................................... 8
INSTALLATION .................................................................................................................... 9
Digital KVM over IP Switch Setup ................................................................................ 9
Server Conguration ..................................................................................................... 9
Network Settings .........................................................................................................12
Port Base Settings .......................................................................................................13
Conguration of the Firewall/Router for Access across the Internet ...........................14
Installation of Certicates ............................................................................................14
Selection of a Security Level for Viewer Connection ................................................. 16
Selection of a User Password Policy ...........................................................................17
VIEWER CONNECTION.................................................................................................... 18
Installation of a Win32 Viewer .....................................................................................18
Installation of a Java Viewer ........................................................................................18
Importing Certicates to a Viewer on a Client Computer ............................................19
Viewer Connection Options ........................................................................................ 20
Establishing the Viewer Connection ........................................................................... 21
Cursor Settings/Synchronization ................................................................................ 21
Saving Connection Settings ....................................................................................... 21
Win32 Viewer Settings................................................................................................ 22
Title Bar Information ................................................................................................... 24
Select Computer Box .................................................................................................. 24
Viewer Quick Menu ..................................................................................................... 24
Video Display Troubleshooting ................................................................................... 26
MANAGEMENT OVER A SECURE HTTPS BROWSER .................................................. 27
Web-Based Management Interface............................................................................ 27
Download .................................................................................................................... 29
Main: Date & Time ...................................................................................................... 30
Main: Security ..............................................................................................................31
Main: LAN TCP/IP ...................................................................................................... 33
Main: WAN PPP .......................................................................................................... 34
KVM Server: Log ........................................................................................................ 37
KVM Server: Main Settings ........................................................................................ 38
KVM Server: Viewer Connection (Settings) ............................................................... 40
KVM Server: Computers ............................................................................................ 42
KVM Server: Power Control ....................................................................................... 44
KVM Server: Local Console ....................................................................................... 46
KVM Server: Video Mode Database ...........................................................................47
Users: Local Database ............................................................................................... 48
Users: User Groups .................................................................................................... 50
Users: Remote Servers (User Remote Authentication) ...............................................51
Users: RADIUS Accounting ........................................................................................ 53
Users: Current Status ................................................................................................. 54
section page
4
CONTENTS
5
SYSTEM ARCHITECTURE
SySteM architecture
The Digital KVM over IP Switch is based on an embedded Linux platform for computing power
and rugged stability. It employs a high-speed processor to ensure excellent video quality and
fast keyboard/mouse response across the Internet, even when bandwidth availability is limited.
LAN/WAN Congurations
Tampa
Alarms: E-mails ........................................................................................................... 54
Alarms: SNMP (Traps) ................................................................................................ 55
Alarms: Selection ........................................................................................................ 56
Maintenance: Software Version .................................................................................. 57
Maintenance: Software Upgrade ................................................................................ 57
Maintenance: Firmware Upgrade ............................................................................... 58
Maintenance: Conguration Save & Restore ............................................................. 59
Maintenance: Reboot .................................................................................................. 59
Apply Settings: Restart Servers ................................................................................. 60
APPENDIX A .................................................................................................................... 61
APPENDIX B .................................................................................................................... 64
SPECIFICATIONS ............................................................................................................. 66
Power Control Conguration
6
SYSTEM ARCHITECTURE
Tampa
PPP Conguration
7
SYSTEM ARCHITECTURE
harDware
Front Panel (compressed view)
Status LEDs
• Selected identies a port with a
green light.
• Live identies an on-line port with
a red light.
• Bank No. identies this particular
switch within a daisy-chain conguration.
• 10/100 lights solid orange when the current digital link runs at 100 Mbps.
• Link lights solid green when a network link is established; it ashes whenever network
transmissions are perceived on the digital port.
• Power lights solid red to indicate the power is on.
• Video blinks orange to indicate the normal functioning of the video server.
Rear Panel (compressed view)
Serial Port 1
Connect the serial console
cable for advanced console
management of the switch
via a serial terminal emulation utility, such as Windows HyperTerminal or Linux/Unix Minicom.
Serial Port 2
Connect to either an external modem or a power control unit (or to a cascaded chain of power
control units). When an external modem is added to its serial control port (RJ12), the switch can
serve either as a PPP server to allow direct cable connection or dial-in connection from its
peer computers, or as a PPP client to dial out to an ISP or Enterprise PPP server. Furthermore,
through serial commands sent over its serial control port, the switch can perform remote
power on/off and power cycling tasks via the (cascaded) power control module(s).
Ethernet Port
This digital port (RJ45) offers anytime/anywhere access to the Digital KVM over IP Switch and,
subsequently, the conventional KVM switch(es) and servers/computers connected behind it to
the remote login clients over the LAN/Internet.
PC Ports
Connect to your computer(s) using 3-in-1 connection cable(s).
Restore-to-Default Button
Located to the left of the power jack, it’s accessed by using a pointed object, such as a pin. To
restore the switch to factory defaults (the IP settings and user account settings established
before you do any of your own congurations), press the button for 5 seconds or more.
Power Adapter Jack
Use only the 9 V DC external power adapter included with the switch to avoid nullifying the
warranty.
Daisy Chain Out
Connect to additional switches for daisy-chained (cascaded) congurations.
Console
Connect the keyboard, mouse and monitor for the local console.
8
HARDWARE
Port-switching buttons (8-port model shown) Link
Video
10/100
Selected Live Bank no.
Power
Serial port 2 (serial power control/external modem support)
Serial port 1 (console management)
Restore-
to-default
button
Power adapter jack
Ethernet port PC ports (8-port model shown)
Daisy chain out Local console ports: keyboard, video, mouse
inStallation
Before installing the Digital KVM over IP Switch, take a moment to make sure you have the
following components on hand to ensure a proper setup. (See Appendix B for sample images.)
• Suitable (USB or PS/2) combo KVM cables (or, for added convenience, combo-free cables)
to connect the switch to the keyboard, video and mouse ports of each PC.
• Monitor with standard D-sub 15-pin video connector (HDB15) for each PC.
• Standard PS/2 Microsoft or Logitech keyboard.
• Standard PS/2 Microsoft- or Logitech-compatible ve-key mouse.
• Daisy chain cable (HDB15 male to HDB15 female) as needed for cascade congurations
using conventional 8- or 16-port KVM switches (models 503471 and 503396).
• Terminator (if daisy-chaining) to plug into Daisy Chain Out port of last KVM switch in chain.
Digital KVM over IP Switch Setup
1. Plug the included power adapter into the switch and an AC source, then turn on the switch.
2. Set up your local console by connecting a keyboard, monitor and mouse to the corresponding
Console (keyboard, video and mouse) ports on the switch (see Rear Panel above). NOTE:
Refer to Appendix A for an introduction to basic local console operation.
3. Connect to one or more computers/servers as described below. NOTE: Make sure that PS/2
computers are turned off before connecting to the switch; otherwise, the non-Plug and Play
interfaces may not recognize the PS/2 keyboard and mouse later in the install procedure.
• Single Server Mode (see Page 5 conguration image): To use just one server or computer,
simply connect to a PC port with an appropriate (USB or PS/2) combo cable.
• Multiple Server Mode (see Page 6 conguration image): To connect to multiple servers/
computers, add a conventional KVM switch to the conguration by connecting the Daisy
Chain Out port of the Digital KVM over IP Switch to the Daisy Chain In port of the second
KVM switch, which is then connected to additional computers/servers as desired.
4. Boot up connected computers (if not yet powered on and verify the connections. NOTE:
Do not use both USB and PS/2 keyboard connectors on a computer simultaneously.
Server Conguration
Mouse Acceleration
Mouse acceleration is not supported by the
Digital KVM over IP Switch, so any such
function (including any “Snap To” option)
needs to be deactivated on all connected
servers.
Windows XP:
Go to the Mouse Control Panel, select the
Mouse Properties tab, then go to the Pointer
Options screen.
1. Set the pointer speed slide bar to the
exact middle.
2. Uncheck the “Enhance pointer precision”
option.
3. Uncheck the “Automatically move pointer
to the default button in a dialog box”
option.
4. Click “OK.”
9
INSTALLATION
Windows 2000:
Go to the Mouse Control Panel, select
the Mouse Properties tab, then go to the
Pointer Options screen.
1. Set the pointer speed slide bar to the
exact middle.
2. In the Acceleration panel, select
“None.”
3. Uncheck the “Move pointer to the
default button in dialog boxes” option.
4. Click “OK.”
Windows 98:
Go to the Mouse Control Panel, select
the Mouse Properties tab, then go to the
Motion screen.
1. Set the pointer speed slide bar to
“Slow” (all the way to the left).
2. Click “OK.”
NOTE: As shown above, mouse settings differ depending on the operating platform; some
presenting mouse acceleration options, some not. If you see any mouse acceleration option,
uncheck (deactivate) it. If there is no mouse acceleration available on the Settings screen, adjust
the mouse speed slide bar either to x1 or the slowest position (such as on Linux platforms). In
some cases, a middle position on the speed slide bar may be required for mouse synchronization
on the viewer side (as with Windows XP, for example); or a bit of trial-and-error conguring may
be necessary to set your mouse acceleration to Off and the speed to x1.
Additional Server Conguration Considerations
For optimal performance of the Digital KVM over IP Switch and whatever devices it’s connected
to, keep these conguration points in mind for networked computers and servers.
Select resolution modes that are within the switch’s standard support parameters:
10
INSTALLATION
The Digital KVM over IP Switch supports most display modes up to 1600 x 1200. However, you
might encounter some display problems when your display card is outputting an unusual display
mode, such as no video or an abnormal screen display. To simplify the display factor before
connection to the switch, it’s recommended that more standard display modes be used (see
chart at left). NOTE: These
are suggested display
modes for server desktops;
however, actual feasible
display modes for any
particular server desktop
will be dependent on its
display card. (That is,
some display modes
listed on the chart might
not be feasible with some
display cards, and a trial-
and-error approach may
be more useful in
determining the best
display mode.)
Disable special transition effects on the
screen outputs of your connected servers:
Go to Control Panel ‡ Display ‡
Appearance ‡ Effects. Uncheck any of the
selected options (as needed) in order to
disable transition effects such as Fade for
the menus and tool tips. Perform this same
operation on each of your connected
servers. NOTE: On platforms such as
Windows 98, 2000, XP and Server 2003,
some transition effects might yield
undesirable video refreshing artifacts,
especially when you are using “Medium” or
“Low Video Quality” as your video lter
settings. To prevent undesirable artifacts
from appearing on your screen, deselect the
special transition effects.
Choose plain and solid server desktop
backgrounds for your connected servers:
To optimize the bandwidth efciency and
speed up video performance across the
bandwidth-limited environment, it’s
recommended that you select a relatively
plain server desktop: solid colors or light-
colored graphics. Complex patterns or color
gradients should be avoided if bandwidth is
critical in your application, as they will create
more bandwidth demands for their
transmission across the Internet.
640 640 800 1024 1152 1280 1600
x 400 x 480 x 600 x 768 x 864 x 1024 x 1200
56 Hz
60 Hz X X X X X X
61 Hz
64 Hz
70 Hz X X X X X
72 Hz X X
74 Hz
75 Hz X X X
76 Hz X
78 Hz X
84 Hz
85 Hz X X X X
100 Hz X X X
11
INSTALLATION
Network Settings
1. Connect the Digital KVM over IP Switch to the Ethernet LAN. The factory default network
settings for the switch:
• IP address: 192.168.1.200
• Net mask: 255.255.255.0
• Gateway: 192.168.1.254
• DNS: 192.168.1.254
2. Access the switch’s Web Management interface by entering the following in the address
bar of your browser window on a remote client: https://192.168.1.200:5908.
3. A login prompt displays for the account name (username) and the password. Use the defaults:
• Username: superuser
• Password: superu
After logging in, you will see the Web Management interface.
4. Go to the LAN TCP/IP page on the switch’s Web Management interface and modify your
IP settings. (Refer to Unit Management over a Secure HTTPS Browser Connection / Main /
TCP/IP Settings – Port and IP Settings.)
5. Click “Apply Settings.”
6. Verify the switch’s network connection by connecting to the switch through the Web
Management interface using the new IP address. NOTE: The IP address should be followed
immediately by a colon and the port base +8 for the port number:
https://<IP_address>:<PortBase+8>
For example, if the IP address is 192.168.1.7 and the port base number is 5970, then you
should enter https://192.168.1.7:5978. Remember that it’s a secure SSL-
encrypted connection, so enter “https” instead of the usual “http.” Otherwise, the connection
won’t be established.
12
INSTALLATION
Port Base Settings
NOTE: If you’re satised with the default port base setting as 5900, you can skip this section.
The default port base for switch connection is set at 5900. This means it will use port 5900
(port base) for viewer connection and port 5908 (port base + 8) for https Web browser connection.
• for viewer connection: <Port base>
• for secure browser connection: <Port base + 8>
However, if you intend to use your own port base setting, just access the Web Management
interface and congure the port base. For example, if you choose 5970 as your port base,
then you have:
• for viewer connection: 5970
• for secure browser connection: 5978
Click “Submit” and “Apply Settings” to validate
the new settings. The switch is now installed
within your LAN, and you’re able to proceed
with establishing a remote viewer connection.
13
INSTALLATION
https//192.168.1. 210:5978 /html/ipc onf.html
Conguration of the Firewall/Router for Access across the Internet
To allow access to the Digital KVM over IP Switch behind a corporate rewall/router, establish
the following settings on your rewall/router (not on your switch).
1. Congure a virtual server on your router (or ask your network administrator to do it) as
mapped to the switch’s local IP address.
2. Open a port range (<port_base> – <port_base_+_9>) both inbound and outbound for the
virtual server according to what has been previously congured as the port base for the
switch.
As per the previous example, if the switch is congured with a port base of 5970, then the port
range should be opened as 5970–5979 (i.e., <port_base> – <port_base +9>) both for inbound
and outbound, in which:
• for the switch’s viewer connection port: <port_base> = 5970
• for the browser SSL connection port: <port_base + 8> = 5978
• for viewer internal communication, etc.: <port_base + 9> = 5979
E: Router Internet IP virtual server (port range open) switch’s local IP
61.232.134.120 virtual server (port 5970–5979 open) 192.168.1.7
Once you’ve congured a virtual server with an appropriate port range open (<port_base> –
<port_base_+_9>), you can try to access your switch across the Internet by using a public IP
address and designated port number. Based on the previous example settings:
• Browser access: https:// 61.232.134.120:5978
• Viewer access: 61.232.134.120:5970
If you have domain name mapping to the public IP address, you can also use the domain
name; for example:
• Browser access: https:// www.mycompany.com:5978
• Viewer access: www.mycompany.com:5970
NOTE: Once you’ve changed the port base of your switch, you should also modify the open
port range on your router accordingly if you want Internet access to come across.
Installation of Certicates
NOTE: You can use the default set of certicates (on the included CD) to practice making some
PKI-authenticated connections as long as your network safety isn’t jeopardized. It’s recommended
that this be done within your local area network, assuming it’s well secured with an adequate
rewall and other due precautions against network intrusions. Otherwise, anyone who has a
copy of the default certicates can establish a connection to your servers. If you have already
obtained a set of certicates with the le names and formats required for the switch (which is
strongly recommended), you can use them for viewer authentication. You can also generate
the certicates using software like XCA. (For certicate generation using XCA, refer to “How
to Generate ... Certicates Using XCA” on the included CD.)
First, you need to have these certicates — as mentioned above, if you haven’t obtained your
own certicates, you can use the default set of certicates — ready on your client computers
for uploading to the switch via a Web browser:
For PKI Authentication to be installed on the Digital KVM over IP Switch —
• root certicate (root.crt)
• server certicate (server.crt), and
• server private key (serverkey.pem)
For LDAP Authentication to be installed on the Digital KVM over IP Switch —
• server LDAP certicate (ldapcert.crt), and
• server LDAP private key (ldapkey.pem)
Once you’ve located whichever set of certicates is to be used, you can begin the installation.
‡
‡
‡
‡
‡
‡
‡
‡
14
INSTALLATION
1. Access the switch’s Web Management interface and go to the Security Settings screen.
2. Click “Browse” and use the “Choose File” dialog box to browse and locate your certicate
les.
3. Click “Upload” on the Security Settings screen to upload the root certicate to the switch.
When the upload is completed, the prompt page for rebooting will display.
4. Click “Reboot.” Once the switch has booted back up, continue with the import of the
server.crt and the
serverkey.pem les.
NOTE: You don’t need to
reboot each time you nish
uploading a certicate: You
can do one complete reboot
after you nish uploading all
of them. To return to the
previous Security Settings
screen to upload another
certicate without immediately
going to a reboot, just click
“Security Settings” on the
left side of the screen.
15
INSTALLATION
Selection of a Security Level for Viewer Connection
1. Go to the Security Settings screen on the switch’s Web Management interface and make a
viewer connection selection from the “Security Level” drop-down menu.
• Level 1: No encryption (no SSL)
• Level 2: 256-bit encryption, no user certicate required for user authentication
• Level 3: 256-bit encryption, user certicate required for authentication (PKI)
Security Level 1 offers a non-secured connection, and hence should be used with caution
when the switch is intended to be accessed through an external network. For Level 1, there’s
virtually no encryption.
Security Level 2 offers a secured SSL connection that provides encryption for mouse,
keyboard and video but uses no PKI authentication.
Security Level 3 offers a secured SSL connection that provides encryption for mouse,
keyboard and video, and uses 1024-bit PKI authentication.
The selection of a security level to be implemented for the switch’s viewer
connection is of utmost importance, especially when your remote server connections require
a high level of security in order to keep your servers safe from unauthorized entry and/or
network sniffers.
2. (Optional) If you choose to implement the PKI authentication feature on the switch’s viewer,
you need to select Level 3 security in the Viewer Connection panel on the Security Settings
screen of your Web Management interface.
Then enter the password in the “KVM Server Password” eld. NOTE: You should enter the
password that has encrypted the server private key in the server private key le (serverkey.pem)
16
INSTALLATION
in order to make a successful viewer connection with the switch in the Level 3 security setting.
If you use the standard set of certicates provided on the included support CD, the password
that encrypts the server private key is “serverpwd.” However, if you use your own set of
certicates, you should get the correct server password from the Certicate Authority that
issued those certicates.
3. Go to the Apply Settings screen and click “Restart Servers” to validate your selection.
Selection of a User Password Policy
1. On the Security Settings screen, select one of three options from the “User Password
Policy” drop-down menu.
• No Password
• Global Password
• User Password
If you select “No Password,” anyone can establish a connection without entering a valid
password.
If you select “Global Password,” the viewer will prompt you for a global password, which is
used by all who want to make a viewer connection to the switch.
If you select “User Password,” the viewer will prompt you for a user-specic password. With
this setting, each login user will be checked against his or her corresponding password before
being allowed a viewer connection.
2. Go to the Apply Settings screen and click “Restart Servers” to validate your selection..
NOTE: In all, there are nine (3 x 3) possible combinations of Viewer Security Levels / Password
Policies, allowing administrators to choose the pairing that best suits their particular needs.
User Password Policy and Security Level (SSL/PKI Authentication) settings
should be used with caution: If you adopt No Password Policy and No SSL Encryption / No
SSL Authentication, anyone with a viewer and knowledge of the access IP and port number
of the switch can establish a remote connection.
At this point, your Digital KVM over IP Switch is ready for a PKI-authenticated plus SSL-encrypted
viewer connection! All you need to do is to distribute the following to your remote connection
client(s):
• Certicates (obtained from your Certication Authority and required only if you selected
Level 3 viewer security)
• Certicate password (obtained from your Certication Authority and required only if you
selected Level 3 viewer security; if using the default set of certicates, use “clientpwd”)
• Username and password (specied on the Web Management interface/screen and
required only if you chose the User Password option; if using defaults, use the username/
password combinations Superuser/superu, Admin/123456 or User/123456)
• Global Password (as specied on the Security Settings screen and required only if you
chose the Global Password option)
G = Global Password U = User-specic Password S = 256-bit SSL Encryption P = 1024-bit PKI Authentication N = Not available
17
INSTALLATION
Viewer connection
The Digital KVM over IP Switch provides a Win32 viewer for Windows users and a Java viewer
for cross-platform use on any major operating system.
Installation of a Win32 Viewer
Go to the Download screen to download the Win32 viewer (Kripview_install.exe).
Install the viewer program on the client computer that will connect to the switch.
After installation, a KLE icon (right) will be created on your client desktop.
Installation of a Java Viewer
Before you can use the Java viewer (KViewer.jar) on any OS platform, you should
rst install the Java Runtime Environment, JRE 1.5.0 or higher, which can be
downloaded from www.java.com. To download the Java viewer, just go to the
Download screen of the Web Management interface. NOTE: To run the small Java program,
you don’t have to actually save the Kviewer.jar le to your local hard drive since it isn’t that big
(only 70 kB): You can open it directly. Note
also that on some client platforms — such as
Linux — after you have installed the JRE le
on your client platform, you need to set the
path information in order for the client system
to know where the Java compiler program is.
18
VIEWER CONNECTION
Importing Certicates to a Viewer on a Client Computer
NOTE: If you will be using only the non-PKI-authenticated viewer connections to the switch
(such as Level 1 – no encryption/authentication or Level 2 – 256-bit SSL encryption and only
server authentication by client), you are not obliged to use or import any certicates and you
can skip this section.
To make a fully PKI-authenticated viewer connection with the Digital KVM over IP Switch, you
need to import client certicates to the Win32 viewer and Java viewer on the client computer.
A default set of certicates is provided on the enclosed CD, or you can use your own set of
certicates. If using your own, in addition to importing the client certicates to the Win32/Java
viewer on the remote client computer(s), you should import the root certicate, the server
certicate and the server private key to the switch on the Web Management interface Security
Settings screen. (Refer to Main/Security – Certicate Installation, Viewer Encryption and
Password Policies in the next section.)
The le names of the client certicates can vary (client_name1.p12, client_name2.p12, etc.),
but the certicates and private key for the switch remain as they are (root.crt, server.crt,
serverkey.pem). The client certicates should be imported in the .p12 format, using the import
utility of whichever viewer (Win32 or Java) is on the client computer. NOTE: Make sure you have
the certicates ready for import, either on a transfer device or the local computer hard drive.
If you copy certicates to the local hard drive, you may need to delete them after nishing
the import so others won’t have access to the certicate les. Even though they’re password-
protected, one can never be too careful. Remember, too, that the Win32 and Java viewers
require separate certicate import utilities.
Import a Client Certicate to a Win32 Viewer
Go to Start ‡ Programs ‡ PROSUM ‡
Prima IP Viewer ‡ Import Certicates.
Click “Root Certicate” to import the
root certicate; click “Client Certicate”
to import the client certicate. When the
“successfully imported” message
appears in the text eld, click “Exit” to
proceed.
Import a Client Certicate to a Java Viewer
Go to Start ‡ Programs ‡ PROSUM ‡
Prima IP Viewer ‡ Import Certicates.
Click “Root Certicate” to import the
root certicate; click “Client Certicate”
to import the client certicate. When the
“successfully imported” message
appears in the text eld, close the
window to proceed.
Once you’ve imported certicates to the viewers on the client computer(s), you can make your
viewer connection(s).
19
VIEWER CONNECTION
Viewer Connection Options
The viewer connection option interface presents several options that can be combined in
various ways to optimize your viewer connection. In the Connection Details window, click
“Options” (represented by the top two
screen images at right for Win32; by the
bottom two images for Java).
Compression (Encoding)
Slow Internet: Video quality is optimized for
viewer connection with slower Internet
bandwidth.
Fast Internet: Video
quality is optimized
for connection
with better Internet
bandwidth.
LAN: High video quality
for connection
over the LAN.
No Compression: Best
video quality with
no compression.
Local Cursor Shape
No Cursor: The local
cursor is invisible
on the viewer.
Dot: A dot shape is
used for the local
viewer cursor.
Normal: An arrow
shape is used for the local
viewer cursor.
Misc/Session
Shared Session: Multiple users
access the same server
desktop.
View Only (inputs ignored):
Keyboard and mouse inputs
are ignored (but not restricting
keyboard and mouse access
for other users).
Display
Restrict pixels to 8-bit (for slow networks): Color is reduced to 256 colors for slow connection.
Scale by x/y (server/viewer): Scale the display output on the viewer (but not affecting the actual
transmission bandwidth).
20
VIEWER CONNECTION
Establishing the Viewer Connection
To use the Win32 viewer for connection, run
the viewer program, entering the access IP
address and port number for the switch in the
login window (as shown at right with the
default IP address). NOTE: You can enter the
access IP address without specifying the port
number (as shown), but only when the port
number is defaulted to 5900. (You can also enter the full default address: 192.168.1.200:5900.)
If the port setting on the switch has been changed, the IP address needs to reect this by
specifying the port number at the end. To connect to port 5910 on the server, for example, enter
192.168.1.200:5910. (Refer to Main/LAN TCP/IP – Port and IP Settings for details.)
When prompted for a password or private path phrase, enter the username and password
previously established. The default username/password = superuser/superu; the default global
password (if using the Global Password policy setting) = 123456; the default private path phrase
(if using the Level 3 security setting) = clientpwd. Once these entries have been made, a viewer
connection will be established.
NOTE: If you are using a dial-up modem and experiencing slow keyboard/mouse movement
and response, it could be due to your using the default LAN encoding scheme or even the No
Compression scheme, which requires much more packet quantity in transmitting a video frame.
Or, there could be a network bottleneck somewhere between the switch and your client desktop.
Cursor Settings/Synchronization
Normally, you will see both the local cursor and
the remote cursor in the view area. You can
specify the shape of the local cursor as seen
within the view window: as a dot, an arrow or
none (not showing any local cursor within the
viewer area). If the two cursors become out of
sync, simply press the mouse synchronization
hotkey sequence (right Control, right Control, Home) to re-synchronize them.
NOTE: While operating your mouse, it is not necessary to wait till the remote cursor has actually
caught up with the local one before you can click on the target in the view area: You can click
the target just using the local cursor well before your remote cursor catches up with the target.
Saving Connection Settings
Once you have optimized your viewer connection, you might want
to save the selected connection options. This way, the next time
you log in with the viewer, that specic client computer will use the
stored connection parameters as well as the password (but not the
private path phrase, which is not saved since it is used by a
secured/PKI-authenticated connection) for connection with the
switch. To save connection options, click the icon on the viewer
title bar to display the viewer’s Quick Menu and select
“Save connection options.”
Left: cursors
out of sync;
below: cursors
in sync.
21
VIEWER CONNECTION
Win32 Viewer Settings
Window Size Adjustment
The size of the viewer window can be adjusted by dragging the border of the viewer windows.
Full Screen Mode
For a full-screen display, click the viewer icon
on the title bar of the viewer window to display
the Quick Menu (shown on the left-hand side
of the image at right), then select “Full Screen.”
A message prompt will display as a reminder
of how to exit the Full-Screen mode. Click “OK” and the viewer will present Full-Screen mode.
To exit Full-Screen mode, press Ctrl-Esc-Esc to bring up the local task bar, then right-click the
viewer taskbar icon to bring up the Quick Menu again. Click to de-select Full-Screen and
restore the display to the normal window mode. NOTE: Only the Win32 viewer supports Full-
Screen mode — the Java viewer doesn’t.
Window Size Scaling
To scale the viewer display, click the
viewer icon on the title bar of the
viewer window to display the Quick
Menu, then select “Connection Options.”
With the Connection Options screen
displayed, specify the proportions of
the viewer window that you want, then
select the option. Click “OK” to scale
the window. (In the example at right,
“
1
/
2
” is the specied proportion.)
Centralization of Remote Server Control
If you have multiple units installed in a distributed manner among your global branch ofces, you
can simultaneously monitor different remote servers distributed over this Digital KVM over IP
22
VIEWER CONNECTION
Switch infrastructure using a single client desktop. (Shown below: The upper image presents
ve Win32 viewers on a Windows client desktop, each showing a different remote server
desktop; the lower image presents four Java viewers on a Linux client desktop, each showing
a different remote server desktop.)
23
VIEWER CONNECTION
Title Bar Information
ServerRoom_TPE: This is the name specied for your video server.
Windows XP Professional: This is the name you specied for this connected computer.
54 ms: This is the capture time that is used for capturing the video image.
Shared: This is a shared session that allows other authorized user logins. (“not shared”
indicates a session that blocks others from subsequent logins.)
Optimizing: Indicates the video server is optimizing the video capture from the server desktop.
256-bit encryption: The current viewer session is using 256-bit SSL connection (Level 2 and 3).
PKI Authentication: The current viewer session is PKI-authenticated (Level 3). (“no encryption”
indicates no encryption for signal transmission [Level 1].)
Select Computer Box
Win32 Viewer
The Select Computer box allows you to perform intuitive click-and-
switch operations without memorizing the varied port-switching hotkey
commands that could exist on different kinds of switches installed with
this device. To use the click-and-switch feature, rst congure the
KVM switching hotkey commands for any connected KVM switch(es)
by using the Web Management interface. (Refer to KVM Server/KVM
Switch Database – Keeping and Adding Your KVM Database in the
next section.)
The Select Computer box always displays at the top of your screen
once a proper viewer connection is made. In the box, you can see the
computer icons together with the computer names already specied
for each of them using the Web Management interface. To switch to a
computer, just click its icon in the box. NOTE: These icons only
represent what’s already been registered using the Web Management
interface, and don’t indicate the status of a connection or whether or not the computer is on.
Java Viewer
To display the Select Computer box, click the
“Viewer Computer List” option on the Quick
Menu. (For the Java viewer, the Select
Computer box will not appear by default.) To
switch to a specic computer, click/select any
item on the list.
Viewer Quick Menu
The Quick Menu on the Win32 viewer can be displayed by clicking the program icon at the
upper-left of the title bar or by right-clicking anywhere on the title bar. If using a Java viewer,
just select a menu option from “Actions,” “Settings” or “Information” right below the title bar.
NOTE: The following operations and screen images represent the Win32 viewer. Although the
Java viewer has a slightly different menu arrangement, you should nd it just as easy to use
(except that the “Full screen” option is unavailable on Java).
Select Computer: Select a remote computer using the drop-down combo box (as shown below).
View Computer Icons: Open the “Select Computer” box make a selection by clicking an icon.
Adjust Screen: Fine-tune the screen area by pixel shifts.
24
VIEWER CONNECTION
256
Connection options:
Click to display
the “Connection
Options” window
(below).
Connection info:
This displays the
server connection
information as it relates
to the viewer session.
New connection: Make another new connection using the viewer.
Save connection options: Save the settings (such as those connection
parameters specied in the “Connection Options” window) and
also the password within the registry of the client computer.
NOTE: By selecting this option, you can save your session
password as well as other connection parameters in the registry
of your client computer, so the next time
you log in to the viewer for a new session,
you won’t be prompted for the password
again. However, the client path phrase
required in the connection of Level 3
security (256-bit SSL encryption and PKI
Authentication) won’t be saved and will be
requested every time you log in with the
Level 3 security setting.
Screen refresh: Force-update the viewer
screen output.
Full screen: Change the viewer screen to Full Screen mode.
(Only the Win32 viewer supports this option.)
Send Ctrl-Alt-Del: Send a Log On (Log Off) key sequence to
the remote end.
Scanning: Start scanning through computers by issuing a
programmable port switching command with a delay time
to a conventional KVM switch.
Computer Power Off/On: Send a Power Off (or On) serial port
command to the remote power control unit (only SUPERADMIN or ADMIN is authorized).
25
VIEWER CONNECTION
Video Display Troubleshooting
The video server supports most major display modes up to 1600 x 1200. Some display problems
can occur, however, such as when there is abnormal or unusual display output from your server,
when the display resolution is beyond the maximum support level of 1600 x 1200, or when the
display vertical frequency is beyond the support range in that pixel dimension. A few of the
more common issues are addressed below.
• The video lter may be set at either the Medium or Low quality level. These two levels are
for faster response than is provided by the High setting in order to increase the response
speed in limited bandwidth conditions. If your bandwidth allows — or if you need higher
video quality in lieu of higher speed — just change the video lter from Low to Medium (or
even High). To raise the video lter level, go to the Main Settings screen (in the KVM Server
submenu) and select the lter as either Medium or High Quality. Note that a High Quality
video lter setting provides results at the expense of video response speed on the viewer
screen.
• The transition effects in Windows XP are enabled, which will cause refreshing problems in
Low/Medium Video Filter settings. Thus, if you are using a Low/Medium Quality level of the
video lter, either try to raise the video lter level to High Quality (at the expense of response
speed) or just turn off the transition effects in Windows XP. To turn off the transition effects
in Windows XP, see Additional Server Conguration Considerations, P. 11. Also note that
the local console is not affected at all by the Video Filter settings or by the transition effects
in Windows XP.
• Make sure that the external authentication, PPP server/client, time server and power control
settings are correct. If you don’t use all these features or the authentication/time servers are
not available, just try disabling them to save booting time; otherwise, the switch will try to
look for them till timeout.
There are several ways to increase the response speed on the viewer screen:
• Under bandwidth limited conditions, you should select a more economical encoding scheme,
such as Slow Internet or Fast Internet Encoding instead of the LAN or No Compression
options from the viewer connection menu. However, if the connection is made only within
the LAN with plenty of connection bandwidth, LAN or No Compression encoding schemes
should be (paradoxically) quicker than the Internet scheme – since your client computer
won’t dissipate extra computing power for decoding the more compressed Internet scheme.
• Use 8-bit color reduction (with only 256 colors instead of the 65K colors in 16-bit settings).
• You can enable Automatic Filter Adjustment (Web Management/Video Server screen) for
automatic video optimization based on different bandwidth conditions.
• If you don’t want to use Automatic Filter Adjustment, you could always select either Medium
Quality or Low Quality for more speed as your Video Filter setting. You could also use a
server desktop with smaller resolution (such as 800 x 600) and use a solid, plain-color
background for server desktops.
• Also, check the networking environment to see if there is any bottleneck that can be improved
or eliminated for more bandwidth throughput.
The black strip is the offset that’ll be seen when the display on a viewer screen isn’t centered
correctly because the switch’s automatic centering option isn’t enabled. When the viewer
26
VIEWER CONNECTION
connection is made, select the Adjust Screen option on the viewer’s Quick Menu to display
the Adjust Screen window (as shown on Page 25). Check whether or not you have Automatic
Centering enabled. If it is not yet enabled, select/enable it. If it is already checked, uncheck it,
wait at least 15 seconds, then check the option again to force the video server to align (center)
the display on the viewer screen.
• The switch’s video server may not be functioning properly. First, make sure your account
has the SUPERADMIN privilege. If not, you should request one that has the SUPERADMIN
privilege to do the troubleshooting job for you. Next, go to the Apply Settings screen on the
Web Management interface and click “Restart Servers” to restart the switch. Wait at least 10
more seconds for it to start completely, then try to make the viewer connection again to see
if it is back to normal. Second, If clicking “Restart Servers” doesn’t solve the problem, click
“Emergency Reboot” on the Maintenance screen of the Web Management interface for a
complete start from ground level. An emergency reboot is a clean reboot, and it takes longer
for the switch and video server to load; thus, you need to wait at least a minute for the system
to be up and running. Then try to make the viewer connection again to see if it’s been brought
back to normal. NOTE: A cold boot is always a last resort to bring the switch back: Disconnect
the power adapter from the switch and wait about 30 seconds before plugging it back in and
restarting.
ManageMent oVer a Secure httPS browSer
The switch’s Web Management interface uses only password authentication to authenticate a
login user’s identity. After a user identity is authenticated (that is, if you have entered the right
username with the right password in the login prompt), an SSL-secured browser connection
using 256-bit cipher strength is established.
Web-Based Management Interface
Enter a correct IP address and port number in the address eld:
https://<IP_address>:<port_number> ‡ https://61.222.144.195:5908
27
MANAGEMENT OVER A BROWSER
NOTE: Remember that it’s a secure SSL-encrypted connection, so you should enter “https”
instead of the usual “http”; otherwise, the connection will not be established. The port number
may vary according to its setting on the server. By default, the browser connection uses port
5908. Both the username and password are case-sensitive.
User Privileges: SUPERADMIN, ADMIN, USER
The switch offers three categories of user privileges for Web Management (as indicated by
the varied range of menu listings on the screen images below and the table that follows).
SUPERADMIN: Provides full access to Web Management features (and the Power On/Off
feature on the viewer).
ADMIN: Provides partial access to Web Management features (and the Power On/Off feature
on the viewer).
28
MANAGEMENT OVER A BROWSER
Note the full range of menu options at left.
Note the partial range of menu options at left.
USER: Provides only minimal access to Web Management features (only the Download
screen).
Download
Viewers
The Download menu option lets you download both the Windows and Java viewers.
29
MANAGEMENT OVER A BROWSER
Note the lone menu option at left.
The viewer for Windows can run on most Windows platforms: 98/Me/NT/2000/XP/Server 2003/
Vista. Click “Download” and follow the installation instructions. NOTE: To use the secure full-
SSL connection (Level 3 security), obtain a set of certicates from your administrator. Install the
certicates on your computer by running the Import Certicate utility provided with this viewer.
Refer to the Security section.
The viewer for Java is truly cross-platform for all major operating systems, including Windows,
Linux and Mac OS. However, before you can run the Java viewer on any computer, you must
rst install the Java Runtime Environment (JRE), which is freely available from Sun at http://
www.java.com/. It is recommended to get JRE 5.0 or higher.
On Windows machines, a simple double mouse click should start the viewer for Java. If the
viewer does not start automatically, check the .jar le association on your computer. It must
be javaw.exe (not javaws.exe). On other machines, download the KViewer.jar le into a folder;
then enter: java -jar KViewer.jar. NOTE: Some browsers will automatically change the le
extension from .jar to .zip while you are downloading the le. If this is the case, change the
le extension back to .jar so that you can run it properly. NOTE: To use the secure full-SSL
connection (Level 3 security) with the Java viewer, obtain a set of certicates from your
administrator, download the Import Certicate utility Impcert.jar le into a folder, then enter:
java -jar Impcert.jar. Refer to the Security section.
Main: Date & Time
This screen allows you to congure the time-related settings of your switch, including time zone,
local time and Internet time. After you have made all modications, click “Store Settings” to
save your settings, then click “Apply Settings”/”Restart Servers” to validate these new settings.
NOTE: No change made on this screen will take effect until you click “Apply Settings”/“Restart
Servers.”
Time Zone
Select the time zone/region and city/town from the available list as seen in the drop-down menus.
For example: If the switch is located in Los Angeles, you can choose “America” as your time
30
MANAGEMENT OVER A BROWSER
zone and “Los Angeles” as your region. The advantage of setting up the correct time zone
is that you don’t have to change your local time setting every time you relocate the switch to
a different time zone. Instead, you just change the “Time Zone” settings and let the switch
readjust the local time for you.
Local Time
Enter the correct date (dd-mm-yyyy) and time (hh:mm) here and click “Change Local Time” to
set the current system time on the switch.
Internet Time
If you check the option “Synchronize with an Internet Time Server (NTP),” the time setting will
be periodically synchronized to the time of the NTP server specied on each restart of the
switch and every hour. NTP Server1 is the server the switch will rst try to synchronize with;
NTP Server2 is the backup time server, which the switch will synchronize with when the rst
time server is not available. Just enter the domain name of the time server and click “Store
Settings” to save, then click “Apply Settings”/“Restart Servers” to validate all the modications
you have made for time settings. NOTE: If you choose this option, the original local date and
time settings you manually entered will be refreshed with the time provided bythe Internet time
server. There are many Internet time servers available: Search the Internet for those nearest
your switch installation, as a time server nearer to you will reduce time latency in synchronization.
Main: Security
This screen lets you to congure and implement security-related settings of your switch, such
as uploading your certicates for the server side, selecting the security level of the viewer
connections, and establishing the password policy for the viewer and browser connections.
After you have made all modications, click “Store Settings” to save your settings, then click
“Apply Settings”/”Restart Servers” to validate these new settings. NOTE: No change made on
this screen will take effect until you click “Apply Settings”/“Restart Servers.”
31
MANAGEMENT OVER A BROWSER
Certicates and Keys
Certicates are only needed if you intend to implement full PKI authentication for the viewer
connections. If an SSL-encrypted session is already enough for your security requirements, you
can just ignore this aspect of PKI authentication. Where can you get the certicates? There is
a default set of certicates on your support CD. You can use them to practice the certicate
uploads. In a real-world scenario, you can generate the certicates by yourself (there is some
freeware or shareware, such as XCA, for this purpose); or you can buy certicates from
companies that provide authentication services. The valid le names and formats of the
certicates and keys to be uploaded to the switch should be exactly as shown here: root.crt,
server.crt, serverkey.pem, ldapcert.crt and ldapkey.pem.
Viewer Connections
The browser connections to the Web Management interface are always using SSL connections.
The viewer connections can use different levels of security.
Security Level (SSL): The switch offers three levels of security for viewer connections. From
the drop-down menu, select the level appropriate for your real demands on viewer connection
security: “Level 1,” “Level 2” or “Level 3.”
• Level 1 uses no SSL data encryption and no authentication. It’s the most straightforward
setting and offers the most convenience if there are no security concerns. Anyone who
has a viewer and an Internet connection can easily connect to the switch as long as the
user fullls the password policy requests.
• Level 2 uses SSL encryption for viewer connection, but only requires server authentication
by the viewer client. Remote users are not required to install any certicates on their client
computers. However, the viewer connection is encrypted with 256-bit SSL technology to
ensure that all data contents transmitted via the viewer connection is protected, including
keyboard, mouse and video signals.
• Level 3 uses 256-bit encryption and a bi-directional PKI authentication between the
server and viewer client. With this level of security, all remote users who want to make
viewer connections must install a proper client certicate on their computer. This client
certicate must come from the same CA that issued the root.crt certicate of the switch.
In all, there are nine possible combinations of viewer security levels and password policies
available for the exibility to adapt to your specic security needs.
KVM Server Password: This eld will only appear if you choose to implement Level 3 security.
See Page 16. Enter the password that has encrypted the server private key in the server
private key le (serverkey.pem) in order to make a successful viewer connection with the
switch in the Level 3 security setting. If you use the standard set of certicates provided on
the included support CD, the password that encrypts the server private key is “serverpwd.”
However, if you use your own set of certicates (as you should for a genuinely secure
installation), you need to get the correct server password from the Certicate Authority that
issued those certicates.
First, you should obtain a set of certicates from your administrator. If your certicate les
have different names, change them to the valid names before uploading. To upload the
certicates, click “Browse” to go to the location where your certicates reside. Select a
certicate le, then click “Upload” to upload your certicates, one at a time, to the switch.
After the uploading is completed, you should see the prompt page for a reboot. However,
you don’t have to reboot before you have uploaded all the necessary certicates: Just reboot
once after you’ve uploaded all necessary certicates: root.crt, server.crt and serverkey.pem.
If you need to SSL-encrypt the LDAP connection for user remote authentication, you must
upload two extra certicates: ldapcert.crt and ldapkey.pem.
User-Password Policy: The switch offers three types of password policies for selection from
the drop-down menu: “No Password,” “Global Password” and “User Password.”
• No Password means the viewer will not prompt you for any user password: The door is
open unless you are using Level 3 security.
32
MANAGEMENT OVER A BROWSER
• Global Password means the viewer will prompt you for a global user password, which is
used by all users (a sort of building door code).
• User Password means the viewer will prompt you for your user-specic password (a sort
of apartment door code).
NOTE: The viewer can also prompt you for the client certicate password if you are using
Level 3 security.
Global User-Password: This eld only appears if you select “Global Password” as the password
policy. Enter the common password used by all users here.
NOTE: Password and security (SSL/PKI authentication) settings should be used with caution.
If the switch’s security settings are set to “No Password” and “No SSL” or “No PKI authentication”
(viewer connection security = Level 1), anyone with a viewer and knowledge of the IP address
and port number of the switch can establish a remote connection. With these settings, there
is no password protection and no data encryption. It’s highly recommended
that you (or your network administrator) establish and maintain the proper security for your
switch.
Main: LAN TCP/IP
This screen lets you set up the TCP/IP settings of your switch, including whether or not you want
to use DHCP. Before you proceed with the various settings on this screen, however, you may
rst need to check with your network administrator for proper settings, as improper TCP/IP
settings will result in invalid connections to the switch. After you have made all modications,
click “Store Settings” to save your settings, then click “Apply Settings”/“Restart Servers” to
validate these new settings. NOTE: No change made on this screen will take effect until you
click “Apply Settings”/“Restart Servers.”
33
MANAGEMENT OVER A BROWSER
TCP/IP Settings
TCP Port Base: You can freely specify the port base for viewer connection with the server.
Choose any available port base, starting from the lowest alternative of Port 5900 in
increments of 10 up to Port 6090. The port base you choose is exactly the port number the
switch uses for viewer connection. Also, “port base + 8” is the exact port number you’ll use
for secure http connection to the browser. After you have made the port base modication,
click “Store Settings” and then click “Apply Settings”/“Restart Servers” to effect changes.
Host Name: This is the name the switch will assume on your local area network.
Domain Name: Specify the domain name for your switch as it appears on your LAN. (Leave it
empty if you don’t know.)
Use DHCP: This allows the switch to get all TCP/IP settings automatically from a DHCP server.
IP Address: Enter a xed IP address (in dotted decimal format, such as 192.168.1.200) that
will be used by the switch in your LAN.
Network Mask: Enter a net mask value (in dotted decimal format, such as 255.255.255.0) that
will be used by the switch in your LAN.
Gateway: Enter the xed IP address (in dotted decimal format, such as 192.168.1.254) of the
gateway (e.g., router) to access the Internet.
DNS: Enter the IP address (in dotted decimal format, such as 80.10.246.30) of the DNS server
used by the switch for domain name resolution. (Ask your administrator if you don’t know.)
NOTE: You must enter a valid DNS server IP address for the e-mail alert to be effective.
Main: WAN PPP
This screen lets you set the PPP server/client mode of your switch: to serve either as a PPP
server for the remote computers to dial in for connection or as a PPP client to dial in to a PPP
server to connect to a network or the Internet. The PPP connection can also serve as a backup
connection mode when a direct network connection is not available. The switch’s high-speed
serial interface can offer excellent bandwidth to PPP connections. After you’ve made all
modications, click “Store Settings,” then “Apply Settings”/“Restart Servers.”
34
MANAGEMENT OVER A BROWSER
PPP Mode
There are three PPP options: “Disabled,” “Server” and “Client.”
• Disabled is the default setting.
• Server is for a connection request from a peer computer. It allows users to connect to your
servers without the Internet understructure, and it can be used as a backup access in case
of Internet failure or an ultra-secure access by the use of private lines and modems.
• Client is for a dial-in connection to a PPP server (your ISP or an Enterprise PPP server). It
can be used when there is no LAN or router available for direct Internet access using a modem.
NOTE 1: The PPP connection can work simultaneously with the LAN connection. NOTE 2: The
PPP connection uses the same serial interface as Power Management: As these two features
are mutually exclusive, by enabling the PPP you automatically disable Power Management
and vice versa.
If you have a LAN connection, normally you don’t have to choose the PPP connection as your
connection mode. However, if no LAN connection is available, you can enable either the PPP
Server mode or the PPP Client mode according to the real connection scenarios.
PPP Server Settings
Current Local IP Address: This displays the IP address of the switch when a PPP connection
is established. If the PPP connection is not yet established, however, the IP address will
show as “Unknown.” NOTE: This address is normally the same as the Local IP Address
entry, but must be distinct from the one that is used by the switch on the LAN.
Local IP Address: Enter the IP address (default = 192.168.2.200) to be used by the switch in
the PPP connection. This IP address will be used only in PPP connections by the switch
alone, and should be distinct from the IP address (default = 192.168.1.200) that is specied
on the LAN TCP/IP screen and used for connection via direct local area network.
35
MANAGEMENT OVER A BROWSER
Peer IP Address: Enter the IP address (default= 192.168.2.201) that will be assigned by the
switch to the peer client at connection time.
Maximum Speed: Specify the modem connection speed. The switch supports a high-speed
serial connection up to 1 Mbps (megabits per second). NOTE: The modem connection
speed is not the PPP connection speed, which depends on the modem technology. For
example, even if the modem connection speed is 115,200 bps, a 56K modem will provide
only a 56,000 bps PPP connection.
User Name: Specify the username that must be used for the PPP connection login by the peer
computer on the other side of the phone line/serial connection.
Password: Specify the password that must be used by the peer computer, then enter the same
password in the next entry eld to conrm the password. NOTE: The switch can support
only one User Name / Password combination and one PPP connection at a time.
Modem Initialization (chat script style): The modem initialization script is a chat script that will
initialize the modem to be ready for connection. The standard script provided by default
permits you to connect a Windows client to the switch in Server mode over a direct serial
cable (null modem). As shown:
TIMEOUT 3600
CLIENT CLIENTSERVER\c
In other words: Wait for “CLIENT” one hour before timeout, and respond “CLIENTSERVER”
without a carriage (hard) return. NOTE: Refer to the Power Management screen for more
details about the chat program. Also refer to your modem documentation; for Linux users,
to the standard manual pages of pppd and chat programs. In Server mode, the modem
should be set to wait and automatically connect when receiving remote calls.
PPP Client Settings
Current Local IP Address: This displays the dynamic IP address assigned to the switch by the
36
MANAGEMENT OVER A BROWSER
PPP server at connection time; for example, 62.147.111.39. If the PPP connection is not yet
established, however, the IP address will show as “Unknown.” NOTE: This address is used
by the switch as a PPP client, and thus is distinct from the one that is used by the switch on
the LAN.
Maximum Speed: Specify the modem connection speed. The switch supports a high-speed
serial connection up to 1 Mbps (megabits per second). NOTE: The modem connection
speed is not the PPP connection speed, which depends on the modem technology. For
example, even if the modem connection speed is 115,200 bps, a 56K modem will provide
only a 56,000 bps PPP connection.
User Name: Specify the username that will be used by the switch to connect to the PPP server.
Password: Specify the password that will be used by the switch to connect to the PPP server.
NOTE: The username and password are normally provided by the ISP at subscription time.
Modem Initialization (chat script style): The modem initialization script is a chat script that will
initialize the modem to be ready for connection. The standard script provided here by default
cannot work for a client connection. Replace it with your own initialization script depending
on your modem. NOTE: Refer to the Power Management screen for more details about the
chat program. Also refer to your modem documentation; for Linux users, refer to the standard
manual pages of pppd and chat programs. In Client mode, the modem should be set to dial
automatically at start time.
KVM Server: Log
This screen presents a detailed record of events — beginning from each restart — of each user’s
login, port switching actions and video modes. It also records each login attempt and the IP
37
MANAGEMENT OVER A BROWSER
address from which the login attempt originated, even when the attempt was not successful.
Also, it will show certain technical details, such as the compression ratio, encoding scheme
and bytes transmitted in each successful viewer session. This is the screen you should view
rst if you want to know the usage/“health” conditions of your switch.
Enable Log: Select to enable the logging of switch server events. If you choose to not enable
this option, no logging will be done.
Print Statistics: If you need to know more about the switch’s server statistics — such as the
compression ratio, bytes transmitted, rectangles drawn, frame buffer updates and key events
received — select this option so that you can have quantied data for the prole of each
session. To record the statistics of the video server and port switching activity by the switch’s
remote users, select this option to print statistics to the server log le.
Each log entry is preceded by a date code, time stamp and description of the specic log event.
Look here for the IP address that is assumed by login users when they made the login attempt,
and for the statistics of each session as a useful reference for the quantied data of each
viewer connection. Note that the log le is of a denite size: Older log entries will be erased
when the log le has reached its maximum size while newer logging events keep coming in.
Click “Refresh” to update the screen output of the log le. Since newer server log events may
have occurred and been logged to the database after your previous access of this server log
page, click “Refresh” to reload the log messages. Click “Clear” to erase the log le contents
in the database. NOTE: The server log is erased each time you perform a complete reboot
remotely by hitting “Reboot” on the Maintenance/Reboot screen or when the switch suffers a
power loss.
KVM Server: Main Settings
This screen allows you to set up the KVM server operation: video quality and optimization, KVM
switch model and the auto scanning function. After you’ve made all modications, click “Store
Settings,” then “Apply Settings”/“Restart Servers.”
Video Quality
Filter Level: Based on the desired (or required) combination of video quality and available
bandwidth, select one of three video lter levels for the switch’s video server: “High Quality,
Low Speed,” “Medium Quality, Medium Speed” or “Low Quality, High Speed.” Understand
that there’s always a trade-off between video quality and response speed when constrained
by limited network bandwidth availability.
• High Quality, Low Speed (light lter) is recommended for high bandwidth networks such
as a LAN or broadband Internet. It requires more bandwidth than the other two lter levels
and video refresh speed is slower (only noticeable, though, when bandwidth is very
limited). This lter provides the best image quality.
• Medium Quality, Medium Speed (medium lter) is recommended for Internet connections.
It requires more bandwidth than the “Low Quality, High Speed” option, but is most often
the best speed/bandwidth compromise.
• Low Quality, High Speed (strong lter) is recommended for very limited bandwidth
conditions, such as a dial-up modem line to the Internet. With this setting, the viewer screen
is updated only on big video changes. Most of time there will be no transmission at all.
Automatic Filter Adjustment: When this option is selected, the switch can tune the video lter
automatically for optimized performance according to the current bandwidth availability.
Automatic Screen Alignment: When this option is selected, the switch tries to center the view
screen automatically to eliminate the offsets sometimes seen on the viewer screen as black
gaps.
Automatic Image Optimization for Speed: When this option is selected, the switch tries to
optimize the video settings (phase, light and contrast) to produce images of better quality
with higher compression.
38
MANAGEMENT OVER A BROWSER
Attached KVM
Model: If you ever use a KVM switch behind this Digital KVM over IP Switch for connection
with multiple computers, you should select the model of that KVM switch. If the KVM switch
model does not appear on the list, you can always add it or even add more KVM switch
models to augment the list so that your computer icons can support the port switching
hotkeys of that specic KVM switch when they’re clicked. (For details about adding a KVM
switch model to the KVM switch database, go to the KVM Switch Database section; for
details about naming a computer as it appears on the computer icon of the Select Computer
box, go to the Computers section.)
Number of Computers: Specify a maximum allowable number of connected PCs for the KVM
switch attached behind this Digital KVM over IP Switch. The maximum is 256 computers, as
you might have with a conguration of several cascadable KVM switches behind this Digital
KVM over IP Switch.
Scanning
Scanning Period: This is the default scanning duration for each connected PC, if no KVM
(keyboard/video/mouse) event happens to interrupt the scanning. If there is a KVM event,
such as keyboard/mouse movement or a video resolution change, the scanning will be
temporarily paused until it reaches the timeout of the scanning delay, then continue. Specify
the scanning period in seconds.
Scanning Delay: This is the time that the switch will wait after it last perceives a KVM (keyboard/
video/mouse) event before it switches to the next connected PC.
Performing the NumLock Test While Scanning: The NumLock test is a way to detect whether
39
MANAGEMENT OVER A BROWSER
or not a computer is still responding to keyboard actions. If you select this option, the switch
will send a NumLock signal to the PC while scanning. If the PC sends a response, then the
NumLock LED will light. The NumLock test can determine if the connected PC is still
responsive to keyboard events. Additionally, the NumLock signal will serve as a “wake up”
signal if the PC is in Sleep mode. If the NumLock test has failed, it most likely indicates that
your computer is in trouble. Select this option if you want to use auto-scanning to monitor
whether or not each of your computers has stayed alive. You can also specify which computer
will be included in the auto-scanning process. (For details about adding/removing computers
from the auto-scanning list, go to the Computers section.)
Also, if combined with the Alarm options, auto-scanning can detect critical server problems
(such as No Video, Blue Screen, NumLock Test failure on rst timing basis) and either send
an alert e-mail or SNMP message or send power cycling commands to a serial power control
device to power cycle the server with the problem. (For details about conguring the alarm
features of the switch, go to the Alarms section.)
KVM Server: Viewer Connection (Settings)
This screen allows you to congure settings proper to the viewer itself, including the name as it
appears on the title bar of the viewer window, the keyboard layout that the switch will assume so
as to be consistent with the one you use on the client side, the biggest resolution support, the
mouse re-sync hot key sequence, and the very convenient and useful feature for anyone using a
double-byte language such as Chinese, Japanese or Korean (the CJK languages) and some
other languages. After you’ve made all modications, click “Store Settings,” then “Apply
Settings”/“Restart Servers.”
40
MANAGEMENT OVER A BROWSER
Server Name for Viewers
Enter the server name you chose for the video server on the switch, and it will appear on the
title bar of your switch’s viewer window.
Keyboard Layout
Choose the keyboard layout for the switch according to the real keyboard you’re using on the
remote login client. Choosing the correct keyboard layout for your keyboard is very important
since some key codes are represented by different keys, depending on the keyboard layout.
Also, a correct keyboard layout setting ensures that you’ll have a key code output on the server
side that matches what you’ve input on the physical keyboard from the client computer side.
The default keyboard layout is the U.S. keyboard, though the switch supports more than 60
types of keyboards used all over the world.
Largest Possible Screen
The switch supports a maximum resolution of up to 1600 x 1200 pixels. Normally, the greatest
resolution support (1600 x 1200) will be the setting that is most accommodating to all display
resolution requirements. However, you can still select a smaller workable resolution for your
display device. If you choose a smaller resolution, be aware that any screen larger than what
you specify here will not be shown on the viewer. The switch supports the following resolutions:
• 640 x 400 • 640 x 480 • 800 x 600 • 1024 x 768 • 1152 x 864 • 1280 x 1024 • 1600 x 1200
(For details about the refresh rate support, go to the Video Mode Database section.)
Hot Keys
The Digital KVM over IP Switch can detect a special sequence of keystrokes when you type on
your remote keyboard. This special sequence is used to ask the switch to resynchronize the
local and remote mouse cursors in a fast and convenient way. For example, it’s faster to press
CTLR–CTLR–Home on the keyboard than to use the mouse and select a command in a menu.
For compatibility with higher devices, this command is divided in two parts: viewer hot keys
and a mouse resynchronization key.
The viewer hot keys are transmitted to the switch or server attached to the switch, whereas the
mouse resynchronization key is ltered out by the switch. Thus, because the viewer hot keys
are transmitted, they must be as harmless as possible. Viewer hot keys such as NumLock-
NumLock, Scrlk-Scrlk or Ctrl-Ctrl can work because they produce, generally, no effect. On the
other hand, the mouse resynchronization key can be anything since it is not transmitted by
TKIP-101.
Hot keys can be congured to t your needs, as well, based on the key positions on a standard
keyboard, as shown below. NOTE 1: The viewer hot keys are transmitted to the switch that’s
attached, thus they must be chosen so that they don’t interfere with the switch’s hot keys.
NOTE 2: If you’re running the Java viewer on a Mac OS, you may nd that the default mouse
resynchronization sequence — CTLR–CTLR–Home — doesn’t work. This is because the
Right Control key on a Mac keyboard sends out a different key code than a PC keyboard does.
If this is the case, consider conguring your hot keys differently (CTLL-CTLL and S, as an
example).
41
MANAGEMENT OVER A BROWSER
Viewer Hot Keys
Enter your preferred keystroke sequence that will serve as viewer hot keys. By default, this is
CTLR–CTLR (two consecutive keystrokes of the Right Ctrl key: CTLR). Note that this is not
the Left Control key (CTLL).
Mouse Resynchronize Key
This is the only command supported by TKIP-101. It permits synchronization of the local and
remote mouse cursors. By default, this is the HOME key. Thus, by default, you have to hit
CTLR–CTLR–HOME to synchronize the remote and the local mouse cursors.
Double-Byte Languages
This feature makes the switch compatible with double-byte languages such as Chinese,
Japanese and Korean. When using the viewer, if the remote computer and/or your local
computer is running a double-byte system, just hit Alt and then Shift or Ctrl and then Shift
sequentially (instead of simultaneously) to produce the same effects.
Enable Hot-Keys Transparent Mode: Select if you are using double-byte language inputs on
the local and/or the remote computer to facilitate switching between single-byte and double-
byte inputs. Leave this option disabled if you don’t use any double-byte languages.
KVM Server: Computers
This screen lets you provide the switch with information about all KVM-attached computers,
which allows various actions to be performed more readily, if not automatically:
• Work with computer names instead of switch port numbers.
• Generate automatically the KVM switch hot keys to select computers so you can select a
computer with a simple mouse click or by using the computer name.
• Generate automatically (or upon request) the power-down and power-on cycling if a power
42
MANAGEMENT OVER A BROWSER
control unit is connected.
• Exclude some computers from the auto-scanning process.
• Refrain from generating alarms for some computers.
NOTE: You can also work without supplying any computer information. In this case, just keep
the values by default. You’ll have to remember on which KVM port your computers are attached
and generate the specic KVM hot keys by hand. (This is the way most low-end IP KVM
extenders work.) After you’ve made all modications, click “Store Settings,” then “Apply Settings”/
“Restart Servers.”
Select the KVM Switch in the Daisy Chain
The various settings on this screen are KVM-switch-specic as well as KVM-port-specic because
a computer is rst identied by the KVM switch and the KVM port it is attached to. Before
conguring any port-specic settings, choose the KVM switch on which you will congure these
settings.
Select the Port Number
Select the KVM port on which your subsequent settings on this screen are directed. You can
use the drop-down menu as well as use the “Previous” and “Next” buttons to navigate to a
specic port.
Computer Name
Enter a character string (32 characters maximum) to identify the computer attached to the
selected port. NOTE: The computer names you specify here for each port will appear in the
Windows and Java viewers.
Scanning
If you don’t want a computer included in auto-scanning, select “Do not include in Scanning
Process.” Thus, you can place a specic computer “off your radar screen” if it is of no monitoring
importance.
Alarms
If you don’t want the scanning process to generate alarms or SNMP messages for this specic
(selected) computer, select “Do not Generate Alarms” to exclude it.
Power Management
If you require power control for your connected computers, you can connect a serial power
control (SPC) device to the serial port on the rear panel of the switch, and then enable the
switch’s power control feature. By doing so, remote users can perform power on/off and power
cycling either via the viewer interface or by a pre-dened alarm-triggered action. The switch can
support most standard serial power control devices via its serial port (RJ12) on the rear panel.
(For details about enabling the switch’s power control feature, refer to the Power Control section
below.)
When using a power control device, note that some newer computers will require
some BIOS option adjustment to restart when power is coming back; otherwise, they will not
restart without pressing the computer power button. Usually, you should enable the Power Loss
Restart option on your computer BIOS (or similar option, depending on the BIOS vendor) so
that your computer can boot up when the power control device is feeding power again.
Power Down Command: Specify the command that must be sent to the power control unit to
power down the computer. (Refer to your power control unit documentation.) NOTE: To
remotely power down this computer from the Windows or Java viewers, switch to this
computer and then click “Power off” in the viewer menu. The command specied here will
be sent automatically by the switch to the power control unit.
Delay: Specify the delay time between the sending of power-down and power-on commands
to complete a power cycling. A power cycling is processed only if you’ve selected “Restart
Computer” on the Alarms screen. By default, this delay is 5 seconds.
43
MANAGEMENT OVER A BROWSER
Power On Command: Specify the command that must be sent to the power control unit to power
on the computer. (Refer to your power control unit documentation.) NOTE: To remotely power
on this computer from the Windows or Java viewers, switch to this computer and then click
“Power on” in the viewer menu. The command specied here will be sent automatically by
the switch to the power control unit.
KVM Server: Power Control
This screen lets you enable or disable the power control feature via the serial port on the rear
panel of your switch. You can also specify the login script of your power control device (if it
requires a login script). After you’ve made all modications, click “Store Settings,” then “Apply
Settings”/“Restart Servers.”
Enable Power Control through the Serial Interface
Select “Enabled” to activate the remote power control support feature of the rear panel serial
port of the switch. Once this option is selected, a subsequent Power Device Login screen will
appear for you to decide whether or not to enter the login script.
Simple Users Can Control Power
Select/check this box if you want simple users to be able to power the computers on and off.
By default, the switch allows only users designated as SUPERADMIN or ADMIN the right to
power on/off the computer from the viewer Quick Menu.
Power Device Login
Depending on the serial power control device you’ve installed behind the switch, you may need
a login script to log in or initialize your power control device. If this is the case, just select the
44
MANAGEMENT OVER A BROWSER
“Power Device Needs a Login” option to display a Login Dialog eld for entering your login
script.
Login Dialog (chat style)
This editable eld is where you should enter the login script for your power control device, if
the device requires it. (Refer to the user guide of your power control device for specics.) A
script consists of one or more “expect-send” pairs of strings separated by spaces, as in the
following example:
login: myid
password: mypass
This script indicates that the switch should expect the string “login:” and, once it’s received the
“login:” prompt, the switch will send the string “myid” and then expect the “password:” prompt.
When it receives the prompt for the password, it will send the password “mypass.” A carriage
return — normally sent following the reply string — is not expected in the expect string unless
it is specically requested by using the \r character sequence.
If the script must start by sending something instead of waiting for an expect string, use the
null sequence ‘’ (two single quotes with no space in between) as the expect string:
‘’ restart
login: myid
password: mypass
In other words, send “restart” and then expect “login:” and then send “myid” and then expect
“password” and then send “mypass.” The expect sequence should contain only what’s needed
to identify the string. For example, to help correct for characters which may be corrupted during
the initial sequence, look for the string “ogin:” rather than “login:” to see if the initial letter (“l”)
was received in error. You may never nd the string even though it was sent by the power
device, so, for this reason, the script should look for “ogin:” rather than “login:” and “ssword:”
rather than “password:” — like this:
ogin: myid
ssword: mypass
Again, in other words, expect “ogin:” and then send “myid” and then expect “ssword:” and then
send “mypass.”
Comments
A comment is a line that starts with the pound sign (“#”) in column 1. Such comment lines are
just ignored. If a “#” character is to be expected as the rst character of the expect sequence,
you should set the expect string in single quote marks (‘’). If you want to wait for a prompt that
starts with a pound sign, you would need to write something like this:
# Now wait for the prompt and send “logout”
‘#’ logout
Escape Sequences
The expect and reply strings may contain escape sequences. All of the sequences are legal
in the reply string; many are legal in the expect. Those not valid in the expect sequence are
so indicated.
A pair of single quotes or apostrophes (‘’ or ’’) — Expects or sends a null string. If you send a
null string, then it will still send the return character.
\b — Represents a backspace character.
\c — Suppresses the new line at the end of the reply string. This is the only way to send a string
without a trailing return character. It must be at the end of the send string. For example, the
sequence “hello\c” will simply send the letters “h,” “e,” “l,” “l,” “o” (not valid in expect).
\d — Delays for one second (not valid in expect).
\n — Sends a new line or linefeed character.
\N — Sends a null character. The same sequence may be represented by “\0” (not valid in expect).
45
MANAGEMENT OVER A BROWSER
\p — Pauses for a fraction of a second. The delay is 1/10th of a second (not valid in expect).
\r — Sends or expects a carriage return.
\s — Represents a space character in the string. This may be used when it is not desirable to
quote the strings which contains spaces. The sequence ‘HI TIM’ and HI\sTIM are the same.
\t — Sends or expects a tab character.
\\ — Sends or expects a backslash character.
For more detailed information, refer to the Linux chat program man page (man 8 chat).
KVM Server: Local Console
This screen allows you to enable or disable the user password authentication feature and
adjust the mouse acceleration on the local console. After you’ve made all modications, click
“Store Settings,” then “Apply Settings”/“Restart Servers.”
Authentication
Local User Needs Authentication: Enable/disable password authentication on the local console.
To enable the password authentication on the Digital KVM over IP Switch local console, you
must select this option.
Mouse Acceleration
Acceleration Rate: From the drop-down menu, select the mouse acceleration factor (x1 to x20)
for the local console.
Acceleration Threshold: This is the point (a value in pixels) at which the local console mouse
acceleration factor goes into effect. NOTE: In order for the mouse resynchronization to work
properly on the viewer, the mouse acceleration on each of the connected servers or computers
46
MANAGEMENT OVER A BROWSER
has to be turned off. A zero-acceleration mouse on a remote server will not reect on the
viewer since the mouse cursor on the remote server should catch up with the mouse on the
viewer side, which could use any acceleration factor. However, on the local console of the
Digital KVM over IP Switch you’ll experience zero mouse acceleration and reduced efciency
when trying to move your mouse. Enabling the mouse acceleration on the local console can
provide more effective mouse maneuvering, yet won’t affect the mouse acceleration on the
connected server since it is only imposed atop its original zero acceleration on the local
console.
KVM Server: Video Mode Database
This screen allows you to modify, create and suppress the VGA modes supported by the device.
After you’ve made all modications, click “Store Settings,” then “Apply Settings”/“Restart
Servers.” Carelessly modifying a video mode in this video database might obliterate
the video capture: Don’t modify anything unless you know exactly what you are doing.
47
MANAGEMENT OVER A BROWSER
Video Mode
Use the drop-down menu to select a video mode from the video mode database. Each video
mode is indicated by the pixel dimension (length by width) at a certain refresh frequency; for
example, 1024 x 768 @ 60 Hz. As with the refresh rate and the pixel dimensions, video mode
parameters — screen width, total width, Hsync start and screen height, total height, Vsync
start — can be adjusted. The following diagram demonstrates the geometric relations between
the VGA parameters.
Refresh Rate
Modify the refresh rate of the target VGA mode as needed.
Width
Screen Width: Specify the width of the visible part of the screen.
Total Width: Specify the total width of the screen (active + hidden).
Hsync Start: Specify where the VGA horizontal synchronization should start with reference to
the beginning of the line.
Height
Screen Height: Specify the height of the visible part of the screen.
Total Height: Specify the total height of the screen (active + hidden).
Vsync Start: Specify where the vertical synchronization should start with reference to the top of
the page.
Click “Store New Settings” to save your modications/additions to the video mode database.
Click “Suppress Selected Mode” to remove the selected video mode from the video mode
database. Click “Restore Previous Settings” to undo the previous addition or elimination of a
video mode. NOTE: You can only undo one move.
Users: Local Database
This screen is for user account management for the switch. You can see the listing of the existing
user entries together with the user group that the specic user belongs to and the description for
the user. You can use the buttons on the top row – “First Page,” “Next Page,” “Previous Page”
and “Last Page” to navigate through the user database listing.
To modify, add or delete an entry, select the target user name in the listing to display a User Edit
screen to make further modications or to create a new user entry. After you’ve made necessary
modications, click “Store User” to save into the user account database.
48
MANAGEMENT OVER A BROWSER
Each of the three user groups — SUPERADMIN, ADMIN and USER — has different rights
regarding the
Web Management
interface and the
viewers.
NOTE: Only
SUPERADMIN
users can manage
user accounts.
49
MANAGEMENT OVER A BROWSER
Users: User Groups
This screen allows you to modify, create or suppress user groups, each of which is listed in the
Select drop-down menu as detailed below. After you’ve made all modications, click “Store
the (new) User Group,” then “Apply Settings”/“Restart Servers.”
Up to 64 user groups can be dened, each having a name and a set of properties specifying
which computers can be accessed and whether the users of this group can power on and
power off the computers they can access. When modifying or creating a new user, you must
select which user group he will belong to (see Users: Local Database above). When implementing
the user-password policy, users are identied at connection time, their group is retrieved and
the group properties are applied.
There are two preset user groups, ADMIN and SUPERADMIN, that cannot be changed. Users
belonging to one these groups can access all computers with no restrictions.
NOTE: The local console user is slightly different. When “Local User Needs Authentication” is
enabled (see KVM Server: Local Console), the local user cannot select the prohibited ports,
but can still access a computer that would be selected by a remote authorized user. Also, user
groups have no effect if the password policy is not set to User Password. If you’re using other
password policies (No Password or Global Password), users willl not have any access
restriction, since when adopting these policies you imply that the distinction of user identities
is not necessary.
50
MANAGEMENT OVER A BROWSER
Select
Select a user group from the local database.
Group Name
Modify this eld if you want to create a new user group. Don’t make changes in this eld if you
only want to change the port list of the current user group.
Power Control
Select “Users of this group can power on/off computers” to allow these users to “manually”
power on and power off the computers they can access through the viewers. NOTE: A power
control device is required to do this.
In the section “Assign ports of the daisy-chained KVM switches to this group,” select which
ports will be authorized for this user group. Check “Set All Ports” to select all KVM ports; check
“Clear All Ports” to remove all KVM ports; check specic port numbers to select each KVM
port individually.
Users: Remote Servers (User Remote Authentication)
This screen allows you to authenticate the users that attempt to connect to the switch from
centralized servers running a RADIUS service or hosting a directory that can be accessed
through the LDAP protocol (Active Directory, for example). User Remote Authentication lets
you integrate the switch into your global enterprise user management.
By default, Remote Authentication is congured as “None”; i.e., all remote authentications
are disabled, in which case the authentication is all done locally by using the database on the
switch only. After you’ve made all modications, click “Store Settings,” then “Apply Settings”/
“Restart Servers.”
51
MANAGEMENT OVER A BROWSER
Authentication Server Type
From the drop-down menu, enable the remote server authentication either by LDAP or the
RADIUS server (or select “None” to disable the remote authentication support). Before
proceeding with subsequent settings on this screen, check with your network administrator for
the availability of either an LDAP server or a RADIUS server.
Directory Server Using LDAP
SSL Access: Select to enable SSL access of the LDAP authentication. NOTE: Make sure your
LDAP server supports SSL, and remember, too, that you need to install a distinct set of
certicates — ldapcert.crt and ldapkey.pem — on the switch by uploading them through the
Security screen. Normally these certicates are generated by the directory server itself.
Port: Enter the port number used in LDAP authentication. By default, it is set to Port 389.
LDAP Server: Enter the IP address of the directory server.
Second Server (if any): If there is a second LDAP server available for authentication, enter its
IP address here.
User Base Search DN: Make an appropriate entry here, which is characteristic of the LDAP
server you use for authentication. The default is cn=users, dc=abc, dc=kle, dc=com, but you
should enter your own. (If unsure what to enter, contact your LDAP server administrator.)
RADIUS Server
Port: Enter the port number used in RADIUS authentication. By default, it is set to Port 1812.
RADIUS Server: Enter the IP address of the RADIUS server.
Second Server (if any): If there is a second RADIUS server available for authentication, enter
its IP address here.
Password Authentication Protocol: Select either “CHAP” or “PAP.”
RADIUS Secret: Specify the RADIUS secret (or Shared Secret) between the switch and the
RADIUS server. The RADIUS secret is a text string used as a password between the RADIUS
client and the RADIUS server. Request the RADIUS secret from your server administrator.
52
MANAGEMENT OVER A BROWSER
Users: RADIUS Accounting
Normally, RADIUS accounting is disabled by default. However, if you have RADIUS accounting
enabled on a RADIUS or LDAP server, you can enable it here and subsequently congure its
relevant settings to take advantage of this feature. After you’ve made all modications, click
“Store Settings,” then “Apply Settings”/“Restart Servers.”
53
MANAGEMENT OVER A BROWSER
Enable RADIUS Accounting
Select to enable RADIUS accounting support and modify the settings.
Port: Specify the port used for RADIUS accounting. By default, it’s set to 1813.
Accounting Server: Enter the IP address of the server offering the RADIUS accounting service.
Second Server (if any): Enter the IP address of the secondary server, if you’ve got any backup
RADIUS accounting server that offers RADIUS accounting service.
RADIUS Secret: Specify the RADIUS secret (or Shared Secret) between the RADIUS client
(e.g., IP KVM) and the RADIUS server. The RADIUS secret is a shared text string used as
a password between the RADIUS client and RADIUS server.
Users: Current Status
This screen displays the remote users currently connected. NOTE: This screen doesn’t refresh
automatically, so to see whether there’s any change, click “Refresh” to update the information.
Only when “User Password” has been selected as your password policy will the
currently connected users be registered and shown on this screen. If you’re using another
password policy (No Password or Global Password), connected users won’t show on this screen
since these policies imply that the distinction of user identities is not necessary.
Alarms: E-mails
This screen allows you to set up the e-mail notication for alarm events. After you’ve made all
modications, click “Store Settings,” then “Apply Settings”/“Restart Servers.”
E-mail From
Sender e-mail address used by the switch for alarm e-mails. This address can help identify
which switch is the sender, and must be accepted by the SMTP server.
E-mail To
The e-mail address(es) of any switch alarm e-mail addressee(s). NOTE: You can use commas
for multiple recipients: support@myaddress.net, emma@international.com, joe@netview.co.jp.
54
MANAGEMENT OVER A BROWSER
Copy To:
The e-mail address of addressees who should get a courtesy copy of alarm e-mails.
SMTP Server:
Enter the name or IP address of the SMTP server (mail server) that will route the switch’s
e-mail alarms to recipients.
Alarms: SNMP (Traps)
This screen allows you to set up the e-mail notication for alarm events. After you’ve made all
modications, click “Store Settings,” then “Apply Settings”/“Restart Servers.”
55
MANAGEMENT OVER A BROWSER
Primary Manager
Specify the IP address of the primary SNMP manager device on your network.
Secondary Manager
Specify the IP address of the secondary SNMP manager device on your network (if any).
SNMP Community
Specify the name of the SNMP community to which your SNMP management host and SNMP
agent should belong. NOTE: The SNMP manager and agents must belong to an SNMP
community identied by its name, which is a collection of hosts grouped together for
administrative purposes.
Alarms: Selection
The switch can be congured to send three types of immediate alerts — e-mails, SNMP traps
or automatic power cycling — in response to three alarm-triggering events: blue screen, no
video or NumLock test failure from a remote computer. This feature should be used in conjunction
with the auto-scan function so that the switch will help carry on a constant surveillance on the
“health” conditions of your connected servers. NOTE: This screen is where you can select
which action the switch is to perform when it detects an event. This is not the screen where
you specify how the action is to be implemented. For this, refer to the SNMP options above.
No Video
This alarm could result from power failure or an unsupported video mode; e.g., an out-of-range
video mode or, most often, a video mode not yet set up in the video database. If you want the
switch to respond immediately to this sort of event, select “Enable Alarm” and which action(s)
you want as a response: restart the computer, send an e-mail and/or send an SNMP trap.
Blue Screen (Text Mode)
A blue screen is the result of a Windows operating system fatal error. It can be detected by its
low resolution video mode. If you want the switch to respond immediately to this event, select
“Enable Alarm” and choose thr screen resolution you want to be regarded as a “blue screen”:
56
MANAGEMENT OVER A BROWSER
600 x 400 or 600 x 480. Then select a response action: “Restart Computer,” “Send an E-mail”
or “Send an SNMP Trap.”
NumLock Test Alarm (Frozen Keyboard)
The NumLock test sends a NumLock signal to the computer, to which the computer normally
returns an immediate response so that the NumLock LED indicator on the keyboard will be lit
to indicate the success of the test. The failure of a NumLock test indicates, at the least, a
keyboard failure to respond to this NumLock signal; otherwise, it could indicate a bigger problem
(such as system failure) or simply a powered-off state. If you want the switch to respond to
this alarm-triggering event, select “Enable Alarm” and which action or actions you want as a
response: restart the computer, send an e-mail or send an SNMP trap.
Maintenance: Software Version
This screen displays the current resident software version information.
Maintenance: Software Upgrade
This screen allows you to browse to the path location of the software upgrade le and upload
the le to the switch across the LAN or Internet. NOTE: The switch upgrade le must have a
name starting with “tkip101” followed by the date: tkip101-yy-mm-dd.
The upgrade le is of an accumulative nature, which means that normally you need only apply
the single latest upgrade patch to keep your switch up to date. When you receive the upgrade
le, you must rst copy it to a local computer, then use the switch’s Web Management interface
to perform the update across your LAN or the Internet.
To perform a software upgrade, click “Browse” to browse to the location of the update le, then
click “Upload.” A running progress indicator bar indicates the ongoing upload process. Depending
on the upgrade le size and the bandwidth availability across the network, the le upload time
can vary from one to 20 minutes. When the upload process is complete, the switch will reboot
by itself. Once the reboot is completed, the switch should work right away.
57
MANAGEMENT OVER A BROWSER
Maintenance: Firmware Upgrade
This screen allows you to browse to the path location of a rmware upgrade le and upload it to
the Digital KVM over IP Switch across a LAN or the Internet.
Generally, the upgrade le comes with a lename formatted as kvmrm-yy-mm-dd, and is
accumulative: You can upgrade the KVM part of the le just as you upgrade the rmware of its
IP module. Just browse to the location of the upgrade le and click “Upload.” A progress status
bar will indicate one to 20 minutes, depending on the le size and bandwidth availability across
the network. When the upload is complete, the switch will reboot by itself.
58
MANAGEMENT OVER A BROWSER
Maintenance: Conguration Save and Restore
This screen allows you to save your current switch settings to a single .tgz le for more portability
and usability. You can also set up several switches with the same or similar congurations.
To back up the conguration le, click “Backup”; choose a location for saving the conguration le
(*.tgz); then click “Save.” The lename format is kcong-yyyymmdd.tgz, with a timestamp in it.
To upload the conguration le, click “Browse” to browse to the location of the update le
(kcong-yyyymmdd.tgz); then click “Upload.” You’ll be prompted for a reboot when the upload
process is complete. Reboot to validate the new conguration.
Maintenance: Reboot
59
MANAGEMENT OVER A BROWSER
If your switch has crashed and simply clicking “Apply Settings”/“Restart Servers” has no effect
on your restoration effort, a last resort is to completely reboot the switch by clicking “Reboot
Device.” NOTE: The reboot brought about by clicking “Reboot Device” is a total reboot and
takes longer to boot up completely, while clicking “Restart Servers” is much quicker (just few
seconds) since it restarts only the server programs on the switch.
Apply Settings: Restart Servers
Any new settings are only committed to the switch’s database by clicking “Store Settings,”
“Store” or “Store User” on each setting screen. However, just clicking any of these buttons
won’t immediately validate these new settings: You should click “Restart Servers” so that new
settings can be put into use at once. NOTE: Clicking “Restart Servers” will disconnect all current
viewer connections. As mentioned above in Maintenance: Reboot, clicking “Reboot” is an option
if clicking “Restart Servers” provides no results, but, as a total reboot, will require more time.
60
MANAGEMENT OVER A BROWSER
aPPenDix a: local conSole oPeration
If you’re unfamiliar with local console operation, this section serves as an introduction to its
controls. Additionally, Appendix B features the cable components needed for initial setup of
the Digital KVM over IP Switch.
There are three ways to operate the Digital KVM over IP Switch: using the front-panel buttons,
keyboard hotkeys and the on-screen display (OSD) menus.
Front-Panel Buttons
The front-panel push buttons are used to directly select the active computer channel that can
be controlled by the shared keyboard, mouse and monitor. Pressing the button during normal
operation will cause the corresponding channel to be selected.
Keyboard Hotkeys
Hotkey control is usually considered the most convenient and quickest way to operate the Digital
KVM over IP Switch on the local console. Most of the hotkey control commands are preceded
by two consecutive Scroll Lock keystrokes (done within 2 seconds) and followed by a specic
command key or key sequence:
Hotkey control command = ScrLk + ScrLk + Command key (sequence)
In most cases, it will take at least three keystrokes to complete a command; in some cases, it
will require six (as when selecting a specic bank and port number as an active channel). All
the available hotkey commands and OSD menu options are summarized in the chart below.
61
APPENDIX A
1 a, b, y and z each denote a number key.
(ab) = 01 – 16; (yz) = 01 – 08 or 01 – 16, depending on the model.
On-Screen Display (OSD)
To activate the OSD menu — which will be superimposed on your current screen display —
use the hotkey sequence ScrLk, ScrLk, Space Bar. The menu presents a listing of available
banks and channels and the current online status of each channel. It also allows you to rename
your computer (up to eight characters), to nd a specic computer by name and to password-
protect your switch system. NOTE: While the OSD is activated, all front-panel buttons and
mice are rendered inactive.
Main Menu
Indicates that the
corresponding computer
is currently the active channel
that can be monitored on your
local console.
Indicates that the
corresponding computer
is currently connected to the
switch via a PS/2 interface and
is feeding power to the switch.
Indicates that the
corresponding computer
is currently connected to the
switch via a USB interface and
is feeding power to the switch. NOTE: Computers listed without any of the above symbols in the
Status column either are not currently connected or are not feeding power to the switch.
As shown in the image above, the bottom of the menu screen displays various key controls. Use
the left, right, up and down cursor keys to navigate within the menu; use the Insert key to edit;
use F1 to move to the next menu screen.
Setup Menu
Auto Logout: Specify the amount
of time (00 – 99 minutes).
Title Bar: Specify the position of
the OSD title bar (or disable it).
Hotkey: Specify the hotkey
preceding sequence.
IP: Specify the local IP address
for the Digital KVM over IP
Switch.
Submask: Specify the submask
for the Digital KVM over IP
Switch.
Firmware Version: Display the
current rmware version.
Local Console Control Options
Some common commands are listed below with the three control options (when applicable)
that can be used to execute each of them: front-panel buttons, keyboard hotkeys and the OSD.
Select PC
• Front-panel buttons: Press the corresponding button on the switch that PC is connected to.
• Hotkeys: ScrLk, ScrLk, (a), (b), (y), (z). In a cascaded (daisy-chained) conguration, for
62
APPENDIX A
example, ScrLk, ScrlLk, 0, 3, 0, 7 would select the computer connected to Bank 3, Port 7.
In a single-switch conguration, however, enter “01” as the bank number — (a) and (b) — in
the hotkey sequence, as this is the default for each individual (and in this case, single) switch.
• OSD: With the OSD menu activated (ScrLk, ScrLk, Space Bar), use the cursor keys to
navigate to the desired channel and press Enter. In a daisy-chain conguration, rst select
the correct bank using the Page Up or Page Down keys.
Next Lower Channel
• Front-panel buttons: Press the corresponding button.
• Hotkeys: ScrLk, ScrLk, Up arrow (since the lower-numbered channel would be in a “higher”
position if displayed in a list).
• OSD: Navigate to and select the corresponding item on the menu.
Next Higher Channel
• Front-panel buttons: Press the corresponding button.
• Hotkeys: ScrLk, ScrLk, Down arrow (since the higher-numbered channel would be in a
“lower” position if displayed in a list).
• OSD: Navigate to and select the corresponding item on the menu.
Next Lower Bank (within a daisy-chain)
• Front-panel buttons: Press the corresponding Port-Switching button on the appropriate
cascaded switch in the conguration.
• Hotkeys: ScrLk, ScrLk, Page Down.
• OSD: Press Page Up.
Next Higher Bank (within a daisy-chain)
• Front-panel buttons: Press the corresponding Port-Switching button on the appropriate
cascaded switch in the conguration.
• Hotkeys: ScrLk, ScrLk, Page Up.
• OSD: Press Page Down.
Beep On/Off
While autoscanning, port-switching or issuing a hotkey command, a beep will sound. If you
want to turn this beeping on or off, use the hotkey sequence ScrLk, ScrLk, B.
OSD Title Bar On/Off
The OSD title bar, which displays the computer name, can be toggled on or off by using the
hotkey sequence ScrLk, ScrLk, T.
OSD Title Bar Position
The OSD title bar can be positioned on either the left or right side of the screen. On the Setup
menu, navigate to the Title Bar option, press Enter to select, then use the cursor keys to
position. The default position is the left side.
Auto Logout
On the OSD Setup menu, navigate to the Auto Logout option, press Enter to select, then
make the desired change to the value (0 - 99 minutes. Auto Logout is disabled by default,
indicated by 00.
63
APPENDIX A
aPPenDix b: inStallation coMPonentS
3-in-1 USB Combo KVM cable
Daisy-Chain cable
(HDB15 male to HDB15 female
Daisy-Chain terminator
3-in-1 PS/2 Combo KVM cable
Combo-Free USB PS/2
KVM cable
64
APPENDIX B
Combo-Free USB PS/2 KVM cable
65
APPENDIX B
Standards
• IEEE 802.1X (Network Access Control)
• IEEE 802.3 (10Base-T Ethernet)
• IEEE 802.3u (100Base-TX Fast Ethernet)
General
• 10/100 Mbps LAN port
• Local console: 1 VGA and 2 PS/2 ports
(1 mouse, 1 keyboard)
• PC connection ports:
- Model 503723: 8 HD15 female connections
for use with 3-in-1 connection cables
(375382, 375399)
- Model 503730: 16 HD15 female connections
for use with 3-in-1 connection cables
(375382, 375399)
• RJ12 console management port
• RJ12 serial control port
• DC In connector
• Protocols supported:
- SSH
- RADIUS
- HTTP
- HTTPS
- SNMP
• Access via Win32 or Java viewer
• Alert e-mail notication and SNMP trap
messages for critical server events (“no
video,” “blue screen of death” and “NumLock
test failure”
• Certications: FCC Class B
Security
• 1024-bit public key authentication using
certicates generated by an external CA
• 256-bit SSL encryption for keyboard, mouse
and video signal transmissions
• Remote authentication support for SSL-
secured LDAP or RADIUS servers
• RADIUS accounting support
• 3 SSL security levels:
- No authentication / no encryption
- Server authentication / SSL encryption
- Server & client authentication / SSL
encryption
• 3 SSL password security levels:
- No password
- 1 global password for all users
- Different password for each user
User Management
• 3 user levels: Superadmin, Admin, User
• Local user database
• Authentication to remote LDAP or RADIUS
server
• User groups with access rights to specic
connected computers
Video
• Supported resolutions:
- 640 x 480 @ 60 Hz / 72 Hz / 75 Hz / 85 Hz /
100 Hz
- 800 x 600 @ 60 Hz / 72 Hz / 75 Hz / 85 Hz /
100 Hz
- 1024 x 768 @ 60 Hz / 72 Hz / 75 Hz /76 Hz /
85 Hz / 100 Hz
- 1152 x 864 @ 60 Hz / 70 Hz / 78 Hz
- 1280 x 1024 @ 60 Hz / 70 Hz
- 1600 x 1200 @ 60 Hz / 70 Hz
• Color depth: 8 and 16 bit
• Quality settings: 3
• Video compression schemes: 4
LEDs
• Link
• 10/100 Mbps
• Power
• Video
• Selected (per port)
• Live (per port)
• Bank number
Environmental
• Dimensions: 410 (W) x 165 (L) x 44.5 (H) mm
(16 x 6.5 x 1.7 in.)
• Weight: 3.6 kg (7.9 lbs.)
• Operating temperature: 0 – 50°C (32 – 122°F)
• Storage temperature: -20 – 60°C (-4 – 140°F)
• Humidity: 0 to 90% RH, non-condensing
External Power Adapter
• Input: 110 - 240 V AC, 50 / 60 Hz
• Output: 9 V DC, 2.0 A
Package Contents
• Digital KVM over IP switch
• Console management cable
• Modem serial cable
• External power adapter
• User manual
• Software CD
• 19” rackmount brackets
SPecificationS
66
SPECIFICATIONS
INTELLINET NETWORK SOLUTIONS™ offers a complete line
of active and passive networking products.
Ask your local computer dealer for more information or visit
www.intellinet-network.com.
Copyright © INTELLINET NETWORK
SOLUTIONS
All products mentioned are trademarks or registered trademarks of their respective owners.